DM670/PM/1/3
Pressure Indicator, Digital, DP670PM Series, 0 to 3 Bar, LCD, 6 Digit, Side Entry
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: STATUS
- Product type: Pressure Transducers
- Product Range: DM670PM Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 250.75 € |
| Current stock | 10+ |
| Lead time | 7 days |
DM670PM FIELD/WALL MOUNTED PRESSURE DISPLAY - **UP TO 100 BAR PRESSURE/ TEMPERATURE DISPLAY WITH SCALING/ LINERIZATION** **BATTERY POWERED, USB AND NFC INTERFACE** **DUAL RELAYS, MAX/ MIN INFORMATION** - **USER SET DISPLAY MESSAGING** - **3600 POINT LOGGER WITH USB AND NFC INTERFACE** ## **INTRODUCTION** The DM670PM series of battery powered indicators accept gauge pressure inputs up to 100 bar and displays the sensor pressure in BAR, PSI or the user’s engineering unit on a 6- digit LCD display. The instrument offers an advanced display mode allowing the user to also display one or two (1 to 32) character messages. Additional to the messages, the user may select an alert event to occur when the pressure is within a band. The two change-over relays can be used together with the messaging and alerts to provide switching at user set points. In addition to this on board datalogging is also available to record process details at up to 3600 points. ## **FEATURE HIGHLIGHTS** ## **DUAL RELAYS** The instrument is equipped with dual volt-free change over type relays, operating independently. The user may select one of seven actions including deviation, latched or non-latched operation, with fully adjustable set point and dead-band. The Relays may be turned off if not required to extend battery life. An option is provided to trigger an alert event when a relay contact is on. ## **DATA LOGGING FUNCTION** DM670PM also provides a powerful data logging function. The log points can be set up to 3600 points, each point is time and date stamped together with process value, temperature and relay state information. The log rate is selectable in steps. The start of log can be delayed if required. Either fixed or rolling logs may be performed. Two methods of reading the log are available. The USB configuration reads the log and allows the user to save to a text file for export to other programs. While the NFC android interface allows data transfer to android phones or tablets and using the downloadable App the data can be graphed and forwarded by email, Bluetooth etc. The NFC interface is also capable of starting a new log with different log period and modes. ## **CALIBRATION/ USER LINEARIZATION** 5-point calibration can be applied using the USBSpeedLink software As well as straight line interpolation up to 22 points (x,y) of user linearization are available for creating custom curves and corrections. ## **REAL TIME CLOCK** Date and time stamped maximum, minimum and average temperature values as well as relay on and relay off data is recorded and can be displayed along with the current time and date. The real time clock is also used to record the data logged points. D2607-01-03 CN5590 DM670PM Data Sheet, Page 1 of 5 DM670PM FIELD/WALL MOUNTED PRESSURE DISPLAY |**INPUT SPECIFICATIONS @20°C**<br>**PRESSURE**|**INPUT SPECIFICATIONS @20°C**<br>**PRESSURE**|**INPUT SPECIFICATIONS @20°C**<br>**PRESSURE**| |---|---|---| |**Type**|**Range**|**Accuracy/ stability**| |Sealed gauge *1|(0 to 3) bar<br>(0 to 30) bar<br>(0 to 100)bar|±0.5% of full scale between (0 to 50) °C *2<br>±0.7% of full scale between (-10 to 80) °C *2| |Overpressure|4 xpressure range|Upto maximum 350 Bar| |Thermal drift||(-10 to 80)°C compensated| |*1 Shows zero Bar at 1.0 Bar absolute<br>*2 Total error band:Maximum deviation within specified pressure and operating temperature range||| |To maintain full accuracyannual calibration is required contact support@status.co.uk for details||| - *1 Shows zero Bar at 1.0 Bar absolute *2 Total error band: Maximum deviation within specified pressure and operating temperature range To maintain full accuracy annual calibration is required contact support@status.co.uk for details |**INPUT SPECIFICATIONS @20°C**<br>**Temperature**|**INPUT SPECIFICATIONS @20°C**<br>**Temperature**|**INPUT SPECIFICATIONS @20°C**<br>**Temperature**| |---|---|---| |**Type**|**Range **|**Accuracy/ stability**| ||(-40 to 110)°C|Typically, ±2.0°C| |||| |**DISPLAY**|**DISPLAY**| |---|---| |**Type/ options/ function**|**Description**| |Displayheight|15.8 mm non-backlit| |Display information options<br>Some information is displayed<br>scrolling.|6 digits 14 segment input value plus “Warning”,” Transmit”, “NFC”,<br>“USB”, “Log”, “Battery”,” Off-set” icons, 8 segment log volume<br>indicators. Maximum, minimum, average*1. Date and time. Custom<br>messages for visual alarms/ information. Relaycondition.| |High intensityLED|Alarm and warningoptions| |*1 Rollingaverage data logis independent of data logging|| |**RELAYS**<br>**Relay 1 and Relay 2**|**RELAYS**<br>**Relay 1 and Relay 2**| |---|---| |**Type/ options/ function**|**Description**| |2 x independent relays|Singlepole change-over(common,N/o, N/c)| |Rating|48 VDC maximum @ 1 A (5 mA minimum)<br>28 VAC RMS maximum@1 A| ## **USB CONFIGURATION USER INTERFACE** |**USB CONFIGURATION USER INTERFACE**|**USB CONFIGURATION USER INTERFACE**|**USB CONFIGURATION USER INTERFACE**| |---|---|---| |**Type/ options/ function**|**Description**|**Notes**| |Configuration hardware|USB Mini B port|Cable not included| |Configuration software|USBSpeedLink|Download www.status.co.uk| |Operatingsystem|Microsoft Windows|Win 7 or later| |Sensor configuration|User calibration<br>Off-set in Bar|Up to 5 points<br>Applied bybutton action| |Display configuration|Display mode<br>Pressure units<br>Custom units|Basic with advanced options<br>°C or °F<br>Bar/ PSI/ mBar/ Pa/ KPa/MPa<br>Kgf/m²/ Kgf/cm²/ Kgf/mm²<br>Atm/ custom units (any)<br>With 22-point linearization| |Pre-set sensor to setpoint|Locks input value to setpoint|For diagnostics| |LED alert (advanced mode)|Eight user adjustable pressure<br>bands|Alert LED flash| |Warning symbol|Out of range<br>Low batterylevel|Warning symbol will flash on LCD<br>display| D2607-01-03 CN5590 DM670PM Data Sheet, Page 2 of 5 DM670PM FIELD/WALL MOUNTED PRESSURE DISPLAY |Basic display mode|Update rate<br>Display variable options<br>Temperature units<br>Push buttons<br>Alert LED<br>Rollingaverage|1 s/ 5 s<br>Input/ input + units/ input + units +<br>temperature<br>°C or °F<br>Active/ active with time stamp/ off<br>Options<br>Period/ number of samples| |---|---|---| |Advanced displaymode *1|Displayvariable(see basic mode)with messagingoptions|| |Batterymonitor|Alert LEDplus message|Relayoption| |Logger|Set device passkey number<br>Clear/ start new log|Device passkey is used to protect the<br>NFC interface.| |Other device options|Synchronise clock<br>Write tag/ contact address<br>Read/ reset maximum and<br>minimum input values<br>Latitude longitude settings|| |Relay control|Name(s)<br>Action<br>Setpoint<br>Dead band<br>Latch|10 characters<br>High/ low/ band/ low battery/ on/ off<br>In engineering units<br>On/ off| |Live data|Read sensor pressure<br>Read displayed value<br>Read sensor temperature<br>Relay 1 state. Relay 2 state<br>Time and date|bar<br>Selected engineering unit<br>°C| |*1 Onlyuse advanced displayabove -5°C ambient temperature, below use basic display||| *1 Only use advanced display above -5°C ambient temperature, below use basic display |**USB LOGGER USER INTERFACE**|**USB LOGGER USER INTERFACE**|**USB LOGGER USER INTERFACE**| |---|---|---| |**Type/ options/ function**|**Description**|**Notes**| |Logger hardware|USB Mini Bport|Cable not included| |Logger software|USBLogLink|Download www.status.co.uk| |Operatingsystem|Microsoft Windows|Win 7 or later| |Logger|Start/set log parameters|Interval/ rate/ (delay) start/<br>number ofpoints/ rollingor fixed log| ||Read log parameters|| ||Stop/ start new log<br>Synchronise device clock<br>Reset maximum and minimum<br>Synchronise/ read clock|| ||View logdata/graph logdata|Save data to CSV file| |**NFC LOGGER USER INTERFACE**<br>**ANDROID**|**NFC LOGGER USER INTERFACE**<br>**ANDROID**|**NFC LOGGER USER INTERFACE**<br>**ANDROID**| |---|---|---| |**Type/ options/ function**|**Description**|**Notes**| |Logger software|NFCLogLink|@Google PlayStore| |Operatingsystem|Android V4.4 Kitkat or later|NFC enabled| |Logger|Start/set log parameters|Interval/rate/ (delay) start/<br>number ofpoints/ rollingor fixed log| ||Read log parameters|| ||Stop/ start new log<br>Synchronise/ read clock<br>Reset maximum and minimum|| ||View logdata/graph logdata|Save data to text file| ||Transfer data via email etc.|Standard Android functions| D2607-01-03 CN5590 DM670PM Data Sheet, Page 3 of 5 DM670PM FIELD/WALL MOUNTED PRESSURE DISPLAY **PUSH BUTTON USER INTERFACE** **==> picture [428 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Button|Description|Notes| |Maximum and minimum|Display/ display and reset|Time and date stamp option| |Offset/ offset reset| |Rolling average option|Number and rate options| |Relay|Display relay configuration|Time and date stamp option| |Reset latched relay| |Relay setpoint adjustment is not possible using front panel buttons, USBSpeedLink required| |Buttons can be locked out to avoided tampering| **----- End of picture text -----**<br> ## **GENERAL** **==> picture [430 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Function|Description| |Update rate|1 or 5 seconds| |Relay response time|< 10 seconds| |Battery|1 x (AA 3.6 V lithium)| |Battery life|1 year minimum|@20°C|(longer depending on options selected)| |Clock accuracy|±2 seconds per month typically| **----- End of picture text -----**<br> ## **ENVIRONMENTAL** **==> picture [375 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Function|Description| |Ambient housing temperature|Operating/storage (-30 to 70)°C| |Ambient sensor temperature|Operating|(-40 to 110)°C| |Ambient humidity|Operating/storage (10 to 90) %RH non-condensing| |Protection|IP65, cable entry must be sealed to IP65| |USB configuration ambient|(10 to 30)°C| **----- End of picture text -----**<br> **==> picture [400 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |CONNECTIONS| |Sensor to process|¼ inch BSP male with adaptor options (see accessories)| |Output relays|2 x Two-part screw connectors| |USB connection|USB mini B port| **----- End of picture text -----**<br> ## **MECHANICAL** **==> picture [359 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Enclosure (case)|Stainless steel, side or base mount options| |Case entry|1 x M16 female thread, blanking|plug supplied| |Front bezel diameter|113 mm| |Weight (approximate)|520|g| |Material in contact with media|Stainless steel 316L| |O-ring|Viton| |APPROVALS| |EMC|BS EN 61326| **----- End of picture text -----**<br> D2607-01-03 CN5590 DM670PM Data Sheet, Page 4 of 5 DM670PM FIELD/WALL MOUNTED PRESSURE DISPLAY ## **ORDER CODE** ||Choose from options below|Choose from options below|Choose from options below||| |---|---|---|---|---|---| ||||||| |**DM670PM**|/ case type|||/ range|| |Case option|||||| |Side entry|I||||| |Rear entry|J||||| |Wall mount|L||||| |Range options|||||| |(0 to 3)Bar||||3|| |(0 to 30)Bar||||30|| |(0 to 100)Bar||||100|| ||||||| |**Example: - DM670PM**|**/ I**|||**/ 3**|| ||||||| |Case Style "I"<br>(Double Side Entry)|Case Style "J"<br>(Double Rear Entry)|||Case Style<br>(Wall Mounting)|Style<br>Mounting)| |||[|23||| ||||D||| |eB,<br>on EntryM16<br>x 1.5<br>E<br>tai<br>Oo<br>—_<br>=<br>ss<br>Sane|Qe|oY<br>—_||NET.<br>rt}<br>=<br>=|Entry| |LJ|||||| |Shown with swivel adaptor fitted.|||||| |**ACCESSORIES**|||||| |Swivel adaptor ¼ BSPP|SA14BSP||||| |Swivel adaptor ½ BSPP|SA12BSP||||| |Swivel adaptor ¼ NPT|SA14NPT||||| |Swivel adaptor ½ NPT|SA12NPT||||| |Swivel adaptor other options available<br>sales@status.co.uk|||||| |Configuration software|USBSpeedLink free of charge from www.status.co.uk||||| |USB loggingsoftware|USBLogLink free of char||Link free of charge from www.status.co.uk|e from www.status.co.uk|| |NFC loggingsoftware|NFCLogLink free of char||Link free of charge refer to Google PlayStore||| |USB lead|USB leadpart number 42-200-0001-01||||| |Battery3.6 V lithium|Contact sales@status.co.uk||||| The data in this document is subject to change. Status Instruments assumes no responsibility for errors Status Instruments Ltd Tel: +44 (0)1684 296818 Status Business Park Fax: +44 (0)1684 293746 Gannaway Lane, Tewkesbury Email: sales@status.co.uk Gloucestershire, UK Website: www.status.co.uk GL20 8FD D2607-01-03 CN5590 DM670PM Data Sheet, Page 5 of 5
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →