Image not available
Illustrative purposes only
DM650PMBC001620
Pressure Indicator, Digital, DM650PM Series, 0 to 3 Bar, LCD, 6 Digit, Wall Mount
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: STATUS
- Product type: Pressure Transducers
- Product Range: DM650PM Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 192.04 € |
| Current stock | 10+ |
| Lead time | 30 days |
DM650PM FIELD/WALL MOUNTED PRESSURE DISPLAY **UP TO 100 BAR PRESSURE / TEMPERATURE DISPLAY WITH SCALING / LINEARISATION** **BATTERY POWERED** **ALARM RELAY, MAX / MIN INFORMATION** **USER SET DISPLAY MESSAGING** **5000 POINT DATA LOGGER WITH USB AND NFC INTERFACE** ## **INTRODUCTION** The DM650PM battery powered indicator accepts gauge pressure inputs up to 100 bar and displays the sensor pressure in BAR, PSI or the user’s engineering unit on a 6- digit LCD display. The instrument offers an advanced display mode allowing the user to also display one or two (1 to 32) character messages. Additional to the messages, the user may select an alert event to occur when the pressure is within a band. A change-over relay can be used together with the messaging and alerts to provide switching at user-set points. In addition to this, on board datalogging is also available to record process details at up to 5000 points. Force calculations (Ram force for example) can also be performed and displayed. ## **FEATURE HIGHLIGHTS** ## **RELAY** The instrument is equipped with single volt-free change-over type relay. The user may select one of several actions, including deviation operation, with fully adjustable set point and dead-band. An option is provided to trigger an alert event when a relay contact is on. ## **DATA LOGGING FUNCTION** DM650PM also provides a powerful data logging function. The log points can be set up to 5000 points, each point is time and date stamped together with process value, and relay state information. The log rate is selectable in steps. The start of log can be delayed if required. Either fixed or rolling logs may be performed. Two methods of reading the log are available. The USB configuration reads the log and allows the user to save to a text file for export to other programs. The NFC android interface allows data transfer to android phones or tablets, and using the downloadable App, the data can be graphed and forwarded by email, Bluetooth etc. The NFC interface is also capable of starting a new log with different log period and modes. ## **CALIBRATION / USER LINEARIZATION** 5-point calibration can be applied using the USBSpeedLink software. As well as straight line interpolation, up to 22 points (x,y) of user linearization are available for creating custom curves and corrections. ## **REAL TIME CLOCK** Date and time can also be displayed with the input pressure. The real-time clock is used to record the data logged points. D2611-01-01 DM650PM Data sheet, Page 1 of 5 DM650PM FIELD/WALL MOUNTED PRESSURE DISPLAY |**INPUT SPECIFICATIONS @20°C**<br>**PRESSURE**|**INPUT SPECIFICATIONS @20°C**<br>**PRESSURE**|**INPUT SPECIFICATIONS @20°C**<br>**PRESSURE**| |---|---|---| |**Type**|**Range**|**Accuracy/stability**| |Sealed gauge *1|(0 to 3) bar<br>(0 to 30) bar<br>(0 to 100)bar|±0.5% of full scale between (0 to 50) °C *2<br>±0.7% of full scale between (-10 to 80) °C *2| ||Other ranges|Contact sales@status.co.uk| |Overpressure|4 xpressure range|Upto maximum 350 Bar| |Thermal drift|(-10 to 80)°C compensated|| |*1 Shows zero bar at 1.0 bar absolute<br>*2 Total error band:Maximum deviation within specified pressure and operating temperature range||| |To maintain full accuracyannual calibration is required contact support@status.co.uk for details||| - *2 Total error band: Maximum deviation within specified pressure and operating temperature range To maintain full accuracy annual calibration is required contact support@status.co.uk for details |**INPUT SPECIFICATIONS @20°C**<br>**Temperature**|**INPUT SPECIFICATIONS @20°C**<br>**Temperature**|**INPUT SPECIFICATIONS @20°C**<br>**Temperature**| |---|---|---| |**Type**|**Range **|**Accuracy/stability**| ||(-40 to 110)°C|Typically, ±2.0°C| |||| |**DISPLAY**|**DISPLAY**| |---|---| |**Type / options / function**|**Description**| |Displayheight|7.9 mm non-backlit| |Display information options<br>Some information is displayed<br>scrolling.|6 digits 14 segment input value plus “Warning”,” Transmit”, “NFC”, “USB”,<br>“Log”, icons, 8 segment log volume indicators. Maximum, minimum. Date<br>and time. Custom messages for visual alarms/information. Relaycondition.| |High intensityLED|Alarm and warningoptions| |**RELAY**|**RELAY**| |---|---| |**Type/ options/ function**|**Description**| |Independent relay|Singlepole change-over(common,N/o, N/c)| |Rating|48 VDC maximum @ 1 A (5 mA minimum)<br>28 VAC RMS maximum@1 A| ## **USB CONFIGURATION USER INTERFACE** |**USB CONFIGURATION USER INTERFACE**|**USB CONFIGURATION USER INTERFACE**|**USB CONFIGURATION USER INTERFACE**| |---|---|---| |**Type / options / function**|**Description**|**Notes**| |Configuration hardware|USB Mini Bport|Cable not included| |Configuration software|USBSpeedLink|Download www.status.co.uk| |Operatingsystem|Microsoft Windows|Win 7 or later| |Sensor configuration|User calibration<br>Off-set in Bar|Up to 5 points<br>Applied bybutton action| |Display configuration|Display mode<br>Pressure units<br>Custom units|Basic with advanced options<br>°C or °F<br>Bar, PS I, mBar, Pa, KPa, MPa<br>Kgf/m², Kgf/cm², Kgf/mm²<br>Atm, custom units (any)<br>With 22-point linearization| |Pre-set sensor to setpoint|Locks input value to setpoint|For diagnostics| |LED alert (advanced mode)|Eight user adjustable pressure<br>bands|Alert LED flash| |Warning symbol|Out of range<br>Low batterylevel|Warning symbol will flash on LCD<br>display| D2611-01-01 DM650PM Data sheet, Page 2 of 5 DM650PM FIELD/WALL MOUNTED PRESSURE DISPLAY |Basic display mode|Update rate<br>Display variable options<br>Temperature units<br>Alert LED|1 s, 5 s<br>Input, input + units, input + units +<br>temperature<br>°C or °F| |---|---|---| |Advanced displaymode *1|Displayvariable(see basic mode)with messagingoptions|| |Batterymonitor|Alert LEDplus message|Relayoption link in software| |Logger|Set device passkey number<br>Clear,start new log|Device passkey is used to protect the<br>NFC interface.| |Other device options|Synchronise clock<br>Write tag, contact address<br>Read, reset maximum and<br>minimum input values<br>Latitude longitude settings|| |Relay control|Name(s)<br>Action<br>Setpoint<br>Dead band<br>Latch|10 characters<br>High, low, band, low battery, on, off<br>In engineering units<br>In engineering units<br>On,off| |Live data|Read sensor pressure<br>Read displayed value<br>Read sensor temperature<br>Relay 1 state. Relay 2 state<br>Time and date|bar<br>Selected engineering unit<br>°C| |*1 Onlyuse advanced displayabove -5°C ambient temperature, below use basic display||| *1 Only use advanced display above -5°C ambient temperature, below use basic display ## **USB LOGGER USER INTERFACE** |**USB LOGGER USER INTERFACE**|**USB LOGGER USER INTERFACE**|**USB LOGGER USER INTERFACE**| |---|---|---| |**Type / options / function**|**Description**|**Notes**| |Logger hardware|USB Mini Bport|Cable not included| |Logger software|USBLogLink|Download www.status.co.uk| |Operatingsystem|Microsoft Windows|Win 7 or later| |Logger|Start/set log parameters|Interval, rate, (delay) start,<br>number ofpoints,rollingor fixed log| ||Read log parameters|| ||Stop, start new log<br>Synchronise device clock<br>Reset maximum and minimum<br>Synchronise,read clock|| ||View logdata, graph logdata|Save data to CSV file| |**NFC LOGGER USER INTERFACE**<br>**ANDROID**|**NFC LOGGER USER INTERFACE**<br>**ANDROID**|**NFC LOGGER USER INTERFACE**<br>**ANDROID**| |---|---|---| |**Type / options / function**|**Description**|**Notes**| |Logger software|NFCLogLink|@Google PlayStore| |Operatingsystem|Android V4.4 Kitkat or later|NFC enabled| |Logger|Start,set log parameters|Interval, rate, (delay) start,<br>number ofpoints,rollingor fixed log| ||Read log parameters|| ||Stop, start new log<br>Synchronise, read clock<br>Reset maximum and minimum|| ||View logdata, graph logdata|Save data to text file| ||Transfer data via email etc.|Standard Android functions| D2611-01-01 DM650PM Data sheet, Page 3 of 5 DM650PM FIELD/WALL MOUNTED PRESSURE DISPLAY ## **GENERAL** |**GENERAL**|**GENERAL**|**GENERAL**| |---|---|---| ||**Function**|**Description**| ||Update rate|1 or 5 seconds| ||Relayresponse time|< 10 seconds| ||Battery|1 x(AA 3.6 V lithium)| ||Batterylife|1year minimum**@20°C** (longer dependingon options selected)| ||Clock accuracy|±2 secondsper month typically| ## **ENVIRONMENTAL** |**ENVIRONMENTAL**|**ENVIRONMENTAL**|**ENVIRONMENTAL**| |---|---|---| ||**Function**|**Description**| ||Ambient housingtemperature|Operating/storage(-30 to 70)°C| ||Ambient sensor temperature|Operating (-40 to 110)°C| ||Ambient humidity|Operating/storage(10 to 90)%RH non-condensing| ||Protection|IP67,cable entrymust be sealed to IP67| ||USB configuration ambient|(10 to 30)°C| |**CONNECTIONS**|| |---|---| |Sensor toprocess|¼ inch BSP male with adaptor options(see accessories)| |Output relay|Two-part screw connectors| |USB connection|USB mini Bport| ## **MECHANICAL** |**MECHANICAL**|**MECHANICAL**|**MECHANICAL**| |---|---|---| ||Enclosure(case)|ABS, greybase, greyclampring,side or base mount options| ||Displaycover|Polycarbonate,clear| ||Case entry|1 x M20 female thread,blanking plugsupplied| ||Front bezel diameter|65 mm| ||Weight(approximate)|250g| ||Material in contact with media<br>O-ring|Stainless steel 316L<br>Viton| ## **APPROVALS** |**APPROVALS**|**APPROVALS**|**APPROVALS**| |---|---|---| ||EMC|BS EN 61326| ||Ingress protection|BS EN 60529| ||RoHS|Directive 2011/65/EU| D2611-01-01 DM650PM NAME Data sheet, Page 4 of 5 DM650PM FIELD/WALL MOUNTED PRESSURE DISPLAY ## **DM650PM ORDER CODE** **==> picture [452 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> Case Style Input Base Side Side Options<br>range entry entry 1 entry 2<br>Side mounted sensor /B /option /00 /16 /option Entry options<br>can be wall mounted 20 = M20<br>Base mounted sensor /C /option /16 /option /00 NPT = ½ inch NPT<br>Input range options in bar<br>C = (0 to 3),<br>D = (0 to 30)<br>G = (0 to 100)<br>Example (0 to 30) bar side mounted sensor M20 entry<br>DM650PM /B /D /00 /16 /20<br>Style B Style C<br>**----- End of picture text -----**<br> ## **ACCESSORIES** Swivel adaptor ¼ BSPP SA14BSP Swivel adaptor ½ BSPP SA12BSP Swivel adaptor ¼ NPT SA14NPT Swivel adaptor ½ NPT SA12NPT Swivel adaptor other options available sales@status.co.uk Hygienic fittings available sales@status.co.uk Configuration software USBSpeedLink free of charge from www.status.co.uk USB logging software USBLogLink free of charge from www.status.co.uk NFC logging software NFCLogLink free of charge refer to Google Play Store USB lead USB lead part number 42-200-0001-01 Battery 3.6 V lithium Contact sales@status.co.uk To maintain full accuracy annual calibration is required contact support@status.co.uk for details The data in this document is subject to change. Status Instruments assumes no responsibility for errors Status Instruments Ltd Tel: +44 (0)1684 296818 Status Business Park Fax: +44 (0)1684 293746 Gannaway Lane, Tewkesbury Email: sales@status.co.uk Gloucestershire, UK Website: www.status.co.uk ~~a~~ GL20 8FD D2611-01-01 DM650PM NAME Data sheet, Page 5 of 5
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →