DLP240-24-1/E
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 75 W, 24 VDC, 3.1 A
- Manufacturer: TDK-LAMBDA
- Product type:
- No. of Outputs:1 Output; Output Power Max:75W; Output Voltage - Output 1:24VDC; Output Current - Output 1:3.1A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Output 3
- SVHC: No SVHC (15-Jan-2018)
- Product Range: DLP Series
- No. of Outputs: 1 Output
- Output Power Max: 75W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 265V AC
- Input Voltage AC Max: 132VAC
- Input Voltage AC Min: 85VAC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3.1A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 119.19 € |
| Current stock | 10+ |
| Lead time | 30 days |
- Low Cost
- 3 Year Warranty
- Semi F47 Compliant (DLP180&240 only)
- Convection Cooled
- Conducted and Radiated EMI, Class B
- Input Transient Protection, IEC61000-4
## **Key Market Segments & Applications**
## DLP Series
75 to 240W, 24V Output DIN Rail Mount Power Supply
Industrial Controls: Motor Control Systems Factory Automation: Process Control, Automotive, Chemical Processing Test & Measurement: Burn in&Test, Instrumentation Measurement
## DLP Features and Benefits ~~SS~~
|**Specifications**<br>MODELS<br>**DLP75-24-1/E**<br>**DLP100-24-1/E**<br>**DLP120-24-1/E**<br>**DLP180-24-1/E**<br>**DLP240-24-1/E**<br>Output Voltage<br>V<br>24<br>24<br>24<br>24<br>24<br>Output Current<br>A<br>3.1<br>4.1<br>5.0<br>7.5<br>10<br>Output Power<br>W<br>75<br>98.4<br>120<br>180<br>240<br>Output Voltage Adjustment<br>V<br>21.6 - 28<br>Load Regulation<br>mV<br>192<br>Line Regulation<br>mV<br>120<br>Ripple/Noise (0-600C)<br>mV<br>240<br>AC Input Voltage & Frequency<br>-<br>85-132/170-265VAC, 47-63Hz Auto select<br>85-265VAC (47-63Hz)<br>or 120-370VDC(1)<br>Input Current 100/230VAC<br>A<br>1.7/0.8<br>2.3/1.2<br>2.4/1.3<br>2.3/1.0<br>3.0/1.3<br>Efficiency 100/230VAC<br>%<br>81/83<br>82/85<br>83/85<br>84/87<br>82/86<br>Power Factor<br>-<br>Meets EN61000-3-2 (DLP180, 240: >0.95)<br>InrushCurrent(Typ)100/230VAC<br>A<br>20/45<br>Leakage Current<br>mA<br>Less than 0.75<br>Hold-up Time 100/230VAC<br>ms<br>20/30 (Semi F47 Compliance, DLP 180 & 240 only)<br>Overcurrent Protection<br>-<br>>105%,Fold Back<br>>105%, Constant Current<br>Overvoltage Protection<br>-<br>30-35V, latching, cycle AC line to reset<br>LED Indicators<br>-<br>Green LED = DC ok Red LED = overcurrent<br>Operating Temperature<br>(2)<br>°C<br>Convection cooled, -10°C to 60°C, derate linearly to 60% load from 50°C to 60°C<br>Storage Temperature<br>°C<br>-30°C ~ +85°C<br>Humidity (Non-Condensing)<br>%RH<br>30-90% operating 10-95% non operating<br>Withstand Voltage<br>-<br>Input - Ground 2kVAC, Input to Output 3kVAC, Output - Ground 500VAC<br>Vibration<br>-<br>9.8m/s2 (1.0G) at DIN rail; (10-55Hz: 9.8m/s2 Constant, X,Y, Z each1hour)<br>Shock<br>-<br>196m/s2 (20G)<br>Safety Agency Approvals<br>-<br>UL508, IEC/UL/CSA/EN62368-1, 60950-1, EN50178 Cat III (Pri), CE Mark<br>Conducted EMI<br>-<br>FCC-B, EN55011/EN55022-B, VCCI-B; Meets IEC61000-4-1<br>Radiated EMI<br>-<br>EN55011/EN55022-B, FCC-Class B, VCCI-B<br>ESD<br>-<br>IEC61000-4-2 ±10kV (Air), ±5kV (Contact)<br>Radiated RFI<br>-<br>IEC61000-4-3 80-1000MHz,12V/m 80% AM 1kHz<br>Fast Transient Burst<br>-<br>IEC61000-4-4 2.4kV 5kHz<br>Lightning Surge<br>-<br>IEC61000-4-5 4.4kV, 1.2x50µs (Common Mode) 2.4kV 1.2x50µs (Normal)<br>Conducted RFI<br>-<br>IEC61000-4-6 150kHz-80MHz, 12V, 80% AM 1kHz<br>Magnetic Field<br>-<br>IEC61000-4-8 36A/m<br>Voltage Dips<br>-<br>IEC61000-4-11 70% 10ms, 40% 100ms, 0% 5s<br>Size<br>mm<br>50 x 97 x 110<br>60 x 97 x 110<br>60 x 97 x 110<br>80 x 97 x 110<br>120 x 97 x 110<br>Weight<br>g<br>470<br>540<br>540<br>780<br>1000<br>Warranty<br>yrs<br>3|**Specifications**<br>MODELS<br>**DLP75-24-1/E**<br>**DLP100-24-1/E**<br>**DLP120-24-1/E**<br>**DLP180-24-1/E**<br>**DLP240-24-1/E**<br>Output Voltage<br>V<br>24<br>24<br>24<br>24<br>24<br>Output Current<br>A<br>3.1<br>4.1<br>5.0<br>7.5<br>10<br>Output Power<br>W<br>75<br>98.4<br>120<br>180<br>240<br>Output Voltage Adjustment<br>V<br>21.6 - 28<br>Load Regulation<br>mV<br>192<br>Line Regulation<br>mV<br>120<br>Ripple/Noise (0-600C)<br>mV<br>240<br>AC Input Voltage & Frequency<br>-<br>85-132/170-265VAC, 47-63Hz Auto select<br>85-265VAC (47-63Hz)<br>or 120-370VDC(1)<br>Input Current 100/230VAC<br>A<br>1.7/0.8<br>2.3/1.2<br>2.4/1.3<br>2.3/1.0<br>3.0/1.3<br>Efficiency 100/230VAC<br>%<br>81/83<br>82/85<br>83/85<br>84/87<br>82/86<br>Power Factor<br>-<br>Meets EN61000-3-2 (DLP180, 240: >0.95)<br>InrushCurrent(Typ)100/230VAC<br>A<br>20/45<br>Leakage Current<br>mA<br>Less than 0.75<br>Hold-up Time 100/230VAC<br>ms<br>20/30 (Semi F47 Compliance, DLP 180 & 240 only)<br>Overcurrent Protection<br>-<br>>105%,Fold Back<br>>105%, Constant Current<br>Overvoltage Protection<br>-<br>30-35V, latching, cycle AC line to reset<br>LED Indicators<br>-<br>Green LED = DC ok Red LED = overcurrent<br>Operating Temperature<br>(2)<br>°C<br>Convection cooled, -10°C to 60°C, derate linearly to 60% load from 50°C to 60°C<br>Storage Temperature<br>°C<br>-30°C ~ +85°C<br>Humidity (Non-Condensing)<br>%RH<br>30-90% operating 10-95% non operating<br>Withstand Voltage<br>-<br>Input - Ground 2kVAC, Input to Output 3kVAC, Output - Ground 500VAC<br>Vibration<br>-<br>9.8m/s2 (1.0G) at DIN rail; (10-55Hz: 9.8m/s2 Constant, X,Y, Z each1hour)<br>Shock<br>-<br>196m/s2 (20G)<br>Safety Agency Approvals<br>-<br>UL508, IEC/UL/CSA/EN62368-1, 60950-1, EN50178 Cat III (Pri), CE Mark<br>Conducted EMI<br>-<br>FCC-B, EN55011/EN55022-B, VCCI-B; Meets IEC61000-4-1<br>Radiated EMI<br>-<br>EN55011/EN55022-B, FCC-Class B, VCCI-B<br>ESD<br>-<br>IEC61000-4-2 ±10kV (Air), ±5kV (Contact)<br>Radiated RFI<br>-<br>IEC61000-4-3 80-1000MHz,12V/m 80% AM 1kHz<br>Fast Transient Burst<br>-<br>IEC61000-4-4 2.4kV 5kHz<br>Lightning Surge<br>-<br>IEC61000-4-5 4.4kV, 1.2x50µs (Common Mode) 2.4kV 1.2x50µs (Normal)<br>Conducted RFI<br>-<br>IEC61000-4-6 150kHz-80MHz, 12V, 80% AM 1kHz<br>Magnetic Field<br>-<br>IEC61000-4-8 36A/m<br>Voltage Dips<br>-<br>IEC61000-4-11 70% 10ms, 40% 100ms, 0% 5s<br>Size<br>mm<br>50 x 97 x 110<br>60 x 97 x 110<br>60 x 97 x 110<br>80 x 97 x 110<br>120 x 97 x 110<br>Weight<br>g<br>470<br>540<br>540<br>780<br>1000<br>Warranty<br>yrs<br>3|**Specifications**<br>MODELS<br>**DLP75-24-1/E**<br>**DLP100-24-1/E**<br>**DLP120-24-1/E**<br>**DLP180-24-1/E**<br>**DLP240-24-1/E**<br>Output Voltage<br>V<br>24<br>24<br>24<br>24<br>24<br>Output Current<br>A<br>3.1<br>4.1<br>5.0<br>7.5<br>10<br>Output Power<br>W<br>75<br>98.4<br>120<br>180<br>240<br>Output Voltage Adjustment<br>V<br>21.6 - 28<br>Load Regulation<br>mV<br>192<br>Line Regulation<br>mV<br>120<br>Ripple/Noise (0-600C)<br>mV<br>240<br>AC Input Voltage & Frequency<br>-<br>85-132/170-265VAC, 47-63Hz Auto select<br>85-265VAC (47-63Hz)<br>or 120-370VDC(1)<br>Input Current 100/230VAC<br>A<br>1.7/0.8<br>2.3/1.2<br>2.4/1.3<br>2.3/1.0<br>3.0/1.3<br>Efficiency 100/230VAC<br>%<br>81/83<br>82/85<br>83/85<br>84/87<br>82/86<br>Power Factor<br>-<br>Meets EN61000-3-2 (DLP180, 240: >0.95)<br>InrushCurrent(Typ)100/230VAC<br>A<br>20/45<br>Leakage Current<br>mA<br>Less than 0.75<br>Hold-up Time 100/230VAC<br>ms<br>20/30 (Semi F47 Compliance, DLP 180 & 240 only)<br>Overcurrent Protection<br>-<br>>105%,Fold Back<br>>105%, Constant Current<br>Overvoltage Protection<br>-<br>30-35V, latching, cycle AC line to reset<br>LED Indicators<br>-<br>Green LED = DC ok Red LED = overcurrent<br>Operating Temperature<br>(2)<br>°C<br>Convection cooled, -10°C to 60°C, derate linearly to 60% load from 50°C to 60°C<br>Storage Temperature<br>°C<br>-30°C ~ +85°C<br>Humidity (Non-Condensing)<br>%RH<br>30-90% operating 10-95% non operating<br>Withstand Voltage<br>-<br>Input - Ground 2kVAC, Input to Output 3kVAC, Output - Ground 500VAC<br>Vibration<br>-<br>9.8m/s2 (1.0G) at DIN rail; (10-55Hz: 9.8m/s2 Constant, X,Y, Z each1hour)<br>Shock<br>-<br>196m/s2 (20G)<br>Safety Agency Approvals<br>-<br>UL508, IEC/UL/CSA/EN62368-1, 60950-1, EN50178 Cat III (Pri), CE Mark<br>Conducted EMI<br>-<br>FCC-B, EN55011/EN55022-B, VCCI-B; Meets IEC61000-4-1<br>Radiated EMI<br>-<br>EN55011/EN55022-B, FCC-Class B, VCCI-B<br>ESD<br>-<br>IEC61000-4-2 ±10kV (Air), ±5kV (Contact)<br>Radiated RFI<br>-<br>IEC61000-4-3 80-1000MHz,12V/m 80% AM 1kHz<br>Fast Transient Burst<br>-<br>IEC61000-4-4 2.4kV 5kHz<br>Lightning Surge<br>-<br>IEC61000-4-5 4.4kV, 1.2x50µs (Common Mode) 2.4kV 1.2x50µs (Normal)<br>Conducted RFI<br>-<br>IEC61000-4-6 150kHz-80MHz, 12V, 80% AM 1kHz<br>Magnetic Field<br>-<br>IEC61000-4-8 36A/m<br>Voltage Dips<br>-<br>IEC61000-4-11 70% 10ms, 40% 100ms, 0% 5s<br>Size<br>mm<br>50 x 97 x 110<br>60 x 97 x 110<br>60 x 97 x 110<br>80 x 97 x 110<br>120 x 97 x 110<br>Weight<br>g<br>470<br>540<br>540<br>780<br>1000<br>Warranty<br>yrs<br>3|
|---|---|---|
||A<br>%<br>-<br>A<br>mA<br>ms<br>-<br>-<br>-<br>°C<br>°C<br>%RH<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>mm<br>g<br>yrs|1.7/0.8<br>2.3/1.2<br>2.4/1.3<br>2.3/1.0<br>3.0/1.3<br>81/83<br>82/85<br>83/85<br>84/87<br>82/86<br>Meets EN61000-3-2 (DLP180, 240: >0.95)<br>20/45<br>Less than 0.75<br>20/30 (Semi F47 Compliance, DLP 180 & 240 only)<br>>105%,Fold Back<br>>105%, Constant Current<br>30-35V, latching, cycle AC line to reset<br>Green LED = DC ok Red LED = overcurrent<br>Convection cooled, -10°C to 60°C, derate linearly to 60% load from 50°C to 60°C<br>-30°C ~ +85°C<br>30-90% operating 10-95% non operating<br>Input - Ground 2kVAC, Input to Output 3kVAC, Output - Ground 500VAC<br>9.8m/s2 (1.0G) at DIN rail; (10-55Hz: 9.8m/s2 Constant, X,Y, Z each1hour)<br>196m/s2 (20G)<br>UL508, IEC/UL/CSA/EN62368-1, 60950-1, EN50178 Cat III (Pri), CE Mark<br>FCC-B, EN55011/EN55022-B, VCCI-B; Meets IEC61000-4-1<br>EN55011/EN55022-B, FCC-Class B, VCCI-B<br>IEC61000-4-2 ±10kV (Air), ±5kV (Contact)<br>IEC61000-4-3 80-1000MHz,12V/m 80% AM 1kHz<br>IEC61000-4-4 2.4kV 5kHz<br>IEC61000-4-5 4.4kV, 1.2x50µs (Common Mode) 2.4kV 1.2x50µs (Normal)<br>IEC61000-4-6 150kHz-80MHz, 12V, 80% AM 1kHz<br>IEC61000-4-8 36A/m<br>IEC61000-4-11 70% 10ms, 40% 100ms, 0% 5s<br>50 x 97 x 110<br>60 x 97 x 110<br>60 x 97 x 110<br>80 x 97 x 110<br>120 x 97 x 110<br>470<br>540<br>540<br>780<br>1000<br>3|
DLP Series
**1**
## Outline Drawing DLP75 Series
**==> picture [62 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
oson() ,pacer):<br>DLP75-24-1/E<br>| wi) Maden Cre CLASS2 POWER* SUPPLY &e<br>EREenwere<br>4<br>Oh SetPere<br>ne) Q.:<br>OR... DLP75-24-1/E re<br>TDK Lambda<br>tian ard wi,<br>**----- End of picture text -----**<br>
## Outline Drawing DLP100/120 Series
**==> picture [29 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
DLP100-24-1/E<br>na<br>Wo<br>eet<br>g-g WAwie<br>DLP100-24-1/E =aTOT,<br>**----- End of picture text -----**<br>
**Notes:** (1) DC input is not safety approved
**==> picture [82 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
Also available<br>DLP-PU<br>parallel unit<br>for redundancy<br>**----- End of picture text -----**<br>
(2) **DLP240-24-1/E** : 170-265VAC: -10°C~+70°C, derated linearly to 60% load from 50° to 70°C.
DLP Series
**2**
## Outline Drawing DLP180 Series
**==> picture [46 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 aA<br>DLP180-24-1/E<br>Deal 2,78 Maximum<br>CT_——_a—a|<br>aca<br>(25 |<br>R25,<br>wn<br>rn<br>“ouwetoaats<br>Continuous Loading<br>mn. BLA<br>DLP180-24-1/E<br>**----- End of picture text -----**<br>
## Outline Drawing DLP240 Series (6.5) 42 t08t rimeDI RAL winewove I. , _ ants a7 | | ® p iI { { ® d| aa | 28a a)||| fe ‘ | I} e |ire| @ ys f COREG A 1} SERRRRRRRREGR)eeseseceseteORE OOO) ses O11)oS8 115Q OOF OROXOROMOM) | OR | iF1|| otetetetete%e%eeececesesecesellseitePeacete tote tetetiletiia:(HIG a1 Petetetetetetesifesiie! ti letocete SOS? fete e*t———lelITA e dif POSES lz 2 it Ye Me Pe %a%e%e%e) r= 2. eteteetete%e%e*ees |=! O CHOKE toteROO eetO 0)1%)tO Ss | OROROXOXOROKOROvateLOMO reteOOOO)! tetetetiie®: | 5O41 | G Derating Curve DLP
**==> picture [94 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
Hy wiv vw a<br>@ wa<br>| l=1Q DLP240-24-1/E ml -<br>Eeea<br>7<br>x fm Ran, REMOVE HOLE<br>NAME PLATE<br>CoN Wow VV o<br>g.82AvB)ae upwinuous Dat Loading24voctoa<br>BZOvAtaE 3.54TT] vax _—— DLP240-24-1/E<br>**----- End of picture text -----**<br>
**==> picture [448 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
DLP75, 120 & 180 Derating Curve DLP100 Derating Graph Curve DLP 240 Derating Curve<br>serserforretssfeccencetecseseedecssceedecseeregicccces DG peeceeeebect eee edecee eee dece cee dee eeeeedeseeeederseees LS CO foe t eres be eee bee eed e reed ee dense = 85-1 70VAC<br>bbedee ZG boven deee be bee deedee SZ 40 b-bd. te 170~265V<br>10 20 30 40 50 60 -10 0 10 20 30 40 50 60 -10 0 10 20 30 40 50 60 70<br>Ta (°C) Ta (°C) Ta (°C)<br>DLP Series 3<br>**----- End of picture text -----**<br>
## **TDK-Lambda France SAS**
Tel: +33 1 60 12 71 65 tlf.fr.powersolutions@tdk.com www.emea.lambda.tdk.com/fr
## **TDK-Lambda Americas**
Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com
## **Italy Sales Office**
Tel: +39 02 61 29 38 63 tlf.it.powersolutions@tdk.com www.emea.lambda.tdk.com/it
## **Netherlands**
## **TDK Electronics do Brasil Ltda**
Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en
tlf.nl.powersolutions@tdk.com www.emea.lambda.tdk.com/nl
## **TDK-Lambda Germany GmbH**
Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de
## **TDK-Lambda Corporation**
Tel: +81-3-6778-1113 www.jp.lambda.tdk.com
## **TDK-Lambda (China) Electronics Co. Ltd.**
Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn
## **Austria Sales Office**
Tel: +43 2256 655 84 tlg.at.powersolutions@tdk.com www.emea.lambda.tdk.com/at
## **Switzerland Sales Office**
Tel: +41 44 850 53 53 tlg.ch.powersolutions@tdk.com www.emea.lambda.tdk.com/ch
## **Nordic Sales Office**
## **TDK-Lambda Singapore Pte Ltd.**
Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com
## **TDK India Private Limited, Power Supply Division**
Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com
Tel: +45 8853 8086 tlg.dk.powersolutions@tdk.com www.emea.lambda.tdk.com/dk
## **TDK-Lambda UK Ltd.**
Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk
## **TDK-Lambda Ltd.**
Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en
For Additional Information, please visit https://product.tdk.com/en/power/
DLP Oct20 v5
DLP Series
**4**
Updated at June 4, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →