DLP180-24/E
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 75 W, 24 VDC, 3.1 A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC DIN Rail Mount Power Supplies
- Product Range: DLP Series
- No. of Outputs: 1 Output
- Output Power Max: 75W
- Input Voltage VAC: 85V AC to 265V AC
- Input Voltage AC Max: 132VAC
- Input Voltage AC Min: 85VAC
- Power Supply Approvals: ITE
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3.1A
- Output Voltage - Output 1: 24VDC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 180.81 € |
| Current stock | 10+ |
| Lead time | 30 days |
**DENSEI-LAMBDA** ## **DLP180-24-1 SPECIFICATIONS** ## **CA735-01-01B** ## **This specifications sheet also apply to option model /E,/EJ** |**CA735-01-01B**<br>**This specifications sheet also apply to option model /E,/EJ**|**CA735-01-01B**<br>**This specifications sheet also apply to option model /E,/EJ**|**CA735-01-01B**<br>**This specifications sheet also apply to option model /E,/EJ**|**CA735-01-01B**<br>**This specifications sheet also apply to option model /E,/EJ**|||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---| |**ITEMS**<br>**MODE**||||**DLP180-24-1**||||||||| |1|Nominal Output Voltage||V|24||||||||| |2|Maximum Output Current||A|7.5||||||||| |3|Maximum Output Power||W|180||||||||| |4|Efficiency (100/230VAC) (Typ)<br>(* 1)||%|84/87||||||||| |5|Input Voltage Range<br>(* 2)|||85 ~ 265VAC(47-63Hz)or 120 ~ 370VDC||||||||| |6|Input Current(100/230VAC) (Typ)<br>(* 1)||A|2.3/1.0||||||||| |7|Inrush Current(100/230VAC) (Typ)<br>(* 3)|||20A at 100VAC,45A at 230VAC,Ta=25~~o~~C,Cold Start||||||||| |8|PFHC|||Built to meet IEC61000-3-2||||||||| |9|Power Factor(Typ)|(* 1)||0.99 / 0.95||||||||| |10|Output Voltage Range||V|21.6~28||||||||| |11|Maximum Ripple & Noise<br>(* 4)|0≤Ta≤60°C|mV|240||||||||| |||-10≤Ta<0°C|mV|360||||||||| |12|Maximum Line Regulation<br>(* 4,5)||mV|120||||||||| |13|Maximum Load Regulation<br>(* 4,6)||mV|192||||||||| |14|Temperature Coefficient|||Less than 0.05%/°C||||||||| |15|Over Current Protection<br>(* 7)||A|7.9~||||||||| |16|Over Voltage Protection<br>(* 8)||V|30.0~35.0||||||||| |17|Hold-UpTime(100/230VAC)<br>(* 1)|||20ms /30ms||||||||| |18|Leakage current<br>(* 9)|||Less than 0.75mA||||||||| |19|Parallel Operation|||-||||||||| |20|Series Operation|||Possible||||||||| |21|( * 10 )<br>Operating Temperature|||- 10 ~ + 60 °C<br>Convection: -10 ~ +50°C(100%);60°C(60%)||||||||| |22|OperatingHumidity|||30 ~ 90 %RH(No dewdrop)||||||||| |23|Storage Temperature|||- 30 ~ +85°C||||||||| |24|Storage Humidity|||10 ~ 95%RH(No dewdrop)||||||||| |25|Cooling|||Convection cooling||||||||| |26|Withstand Voltage|||Input - Output : 3.0kVAC, Input - FG : 2.0kVAC (20mA) for 1min<br>Output - FG : 500VAC(100mA)for 1min.||||||||| |27|Isolation Resistance|||More than 100MΩat Ta=25°C and 70%RH,Output - FG : 500VDC||||||||| |28|Vibration|||At no operating and with DIN RAIL,<br>10~55Hz(Sweepfor 1min)9.8m/s2Constant,X,Y,Z each 1hour||||||||| |29|Shock(Inpackage)|||Less than 196m/s2||||||||| |30|Safety|||Approved by UL60950,CSA60950, EN60950, UL508, CSA C22.2 No14,<br>EN60529 IP20,EN50178 CATEGORY III(Primary),Built to meet DENAN||||||||| |31|EMI|||Built to meet VCCI-B,FCC-ClassB,EN55011/EN55022-B||||||||| |32|Immunity|||Built to meet IEC61000-6-2(IEC61000-4-2,-3,-4,-5,-6,-8,-11)||||||||| |33|Weight(Typ)||g|780||||||||| |34|Size(W.H.D.)||mm|80x97x110(Refer to Outline Drawing)||||||||| |* Read instruction manual carefully , before using the power supply unit<br>= NOTES=<br>* 1 : At 100/230VAC and maximum output power, Ta = 25°C.<br>* 2 : For cases where conformance to various safety specs ( UL, CSA, EN ) are required, to be<br>100 - 240VAC, 50 / 60Hz on name plate.<br>* 3 : Not applicable for the in-rush current to Noise Filter for less than 0.2ms<br>* 4 : Please refer to Fig A for measurement of line & load regulation and output ripple voltage<br>(Measure with JEITA RC-9131 probe)<br>* 5 : 85 - 265VAC, constant load.<br>* 6 : No load - Full load(Maximum power), constant input voltage<br>* 7 : Constant current limit with automatic recovery<br>Avoid to operate at overload or dead short for more than 30seconds<br>* 8 : OVP circuit will shutdown output, manual reset. (Re power on)<br>* 9 : Measured by each measuring method of UL, CSA, EN and<br>DENAN (at 60Hz).<br>*10: At standard mounting method, Fig B.<br> <br>+<br>-<br>Output<br>terminal||||||||described as<br>L<br>V||Output ter||Rail<br>Fig. B<br>Input terminal<br>Fig. A<br> <br>L : 150mm<br>C1 : Elec. Cap 100uF<br> <br>A<br>C2<br>minal| |||||||||||||| ||||||||-|V||+|C1<br>|| |||||||||||||| |||||||||||||| |- Load(%) is percent of maximum output load ( Item2 and 3 ), do<br>not exceed derating in both Maximum Output Current and Power.<br>Measurement point for<br>Vo Line/Load Regulation.<br>Me<br>for||||||||||asurement point<br>Vripple<br>C2 : Film Cap 0.1uF<br>Bandwidth of scope : 100MHz||| - Load(%) is percent of maximum output load ( Item2 and 3 ), do not exceed derating in both Maximum Output Current and Power. - -For standard mounting, refer to derating curve (CA735-01-02_) **DENSEI-LAMBDA** ## **DLP180-24-1 OUTPUT DERATING** ## **CA735-01-02** **(This specifications sheet also apply to option model /E,/EJ)** ## **DLP180-24-1** ||***COOLING: CONVECTION COOLING**| |---|---| |**Ta(°C)**|**LOADING CONDITION(%)**| ||**Standard Mounting**| |**-10~50**|**100**| |**60**|**60**| **==> picture [421 x 259] intentionally omitted <==** **----- Start of picture text -----**<br> OUTPUT DERATING CURVE<br>100<br>80<br>60<br>40<br>20<br>0<br>-10 0 10 20 30 40 50 60<br>Ta (°C)<br>LOAD (%)<br>**----- End of picture text -----**<br> **==> picture [338 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> Output connector<br>Rail<br> Input connector<br> STANDARD MOUNTING<br>**----- End of picture text -----**<br>
Updated at February 9, 2023
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →