Image not available
Illustrative purposes only
DIN30-5
AC/DC DIN Rail Power Supply (PSU), ITE, Industrial & Household, 1 Output, 15 W, 5 V, 3 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TIGER POWER SUPPLIES
- Product type: AC / DC DIN Rail Mount Power Supplies
- No. of Outputs: 1 Output
- Output Power Max: 15W
- Input Voltage VAC: 100V AC to 240V AC
- Power Supply Approvals: ITE, Industrial & Household
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3A
- Output Voltage - Output 1: 5V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 13.19 € |
| Current stock | 10+ |
| Lead time | 7 days |
**AC/DC Converter DIN30-XX Series** ## **30W, AC/DC DIN-Rail Power Supply Series** ## **FEATURES** - **Universal 85-264VAC or 120-370VDC input voltage** - **Accepts AC or DC input (dual-use of same terminal)** - **Operating ambient temperature range -40** ℃ **to +70** ℃ - **High I/O isolation test voltage up to 4000VAC** - **Industrial product technology design** - **Over-voltage class III (Designed to meet EN61558-1 safety standards)** - **Low standby power consumption, high efficiency** - **Low ripple & noise** - **Output short circuit, over-current, over-voltage** - **RoHS protection** - Whis US C€ **Report CB** **Withstand 300VAC surge input for 5s UL62368-1 EN62368-1 IEC62368-1 BS EN 62368-1** UK @ **DIN rail TS35X7.5/ TS35X15 mountable** _**DIN30-XX is Tiger Powers' 30W Din Rail series featuring a cost-effective, energy efficient solution for standard DIN-rail mounting. The products offer a high level of stability and immunity to noise, compliant with international IEC62368 standards for EMC and safety sepecifitions meet IEC/EN61000-4, CISPR32, EN55032, UL62368, IEC62368 and EN62368. These light weight AC-DC converters also have an extremely compact design for space saving and are ideal for applications such as industrial control equipment machinery and all kinds of applications in a harsh environment.**_ ## **Selection Guide** |**Selection** **Guide**|**Selection** **Guide**|**Selection** **Guide**|**Selection** **Guide**|**Selection** **Guide**|**Selection** **Guide**|**Selection** **Guide**| |---|---|---|---|---|---|---| |**Certification**|**Part** **No.**|**Output** **Power**<br>**(W)**|**Nominal** **Output** **Voltage**<br>**and** **Current** **(Vo/Io)**|**Output** **Voltage** **Adjustable**<br>**Range** **ADJ** **(V)***|**Efficiency** **at**<br>**230VAC** **(%)** **Typ.**|**Capacitive** **Load**<br>**(µF)** **Max.**| |**UL/EN/IEC/**<br>**BIS/UKCA**|**DIN30-5**<br>~~a~~<br>~~ee~~|**15**|**5V/3A**|**4.9-5.5**|**82**|**12000**| ||**DIN30-12**<br>~~a~~<br>~~ee~~|**24**|**12V/2A**|**10.8-13.8**|**88**|**6000**| ||**DIN30-15**<br>~~ee~~<br>~~a~~<br>~~ee~~|**30**|**15V/2A**|**13.5-18.0**|**89**|**5000**| ||**DIN30-24**<br>~~ee~~|**36**|**24V/1.5A**|**21.6-29.0**|**88**|**1400**| ||**DIN30-48**<br>~~ee~~|**36**|**48V/0.75A**|**43.2-55.2**|**90**|**600**| |**Note:** ***The** **actual** **adjustment** **range** **may** **extend** **outside** **the** **values** **stated,** **care** **should** **be** **exercised** **to** **ensure** **that** **the** **output** **voltage** **and** **power**<br>**levels** **remain** **within** **the** **published** **maximum** **values.**||||||| **Note: *The actual adjustment range may extend outside the values stated, care should be exercised to ensure that the output voltage and power levels remain within the published maximum values.** ## **Input Specifications** |**Item**<br>**Operating** **Conditions**<br>**Min.**<br>**Typ.**<br>**Max.**<br>**Unit**<br>~~ee~~|**Item**<br>**Operating** **Conditions**<br>**Min.**<br>**Typ.**<br>**Max.**<br>**Unit**<br>~~ee~~|**Item**<br>**Operating** **Conditions**<br>**Min.**<br>**Typ.**<br>**Max.**<br>**Unit**<br>~~ee~~|**Item**<br>**Operating** **Conditions**<br>**Min.**<br>**Typ.**<br>**Max.**<br>**Unit**<br>~~ee~~|**Item**<br>**Operating** **Conditions**<br>**Min.**<br>**Typ.**<br>**Max.**<br>**Unit**<br>~~ee~~| |---|---|---|---|---| |**Input** **Voltage** **Range**<br>**AC** **input**<br>**85**<br>**--**<br>**264**<br>**VAC**<br>**DC** **input**<br>**120**<br>**--**<br>**370**<br>**VDC**<br>~~ee~~<br>~~a~~||||| |**Input** **Frequency**<br>**47**<br>**--**<br>**63**<br>**Hz**<br>**Input** **Current**<br>**115VAC**<br>**--**<br>**--**<br>**0.9**<br>**A**<br>**230VAC**<br>**--**<br>**--**<br>**0.5**<br>**Inrush** **Current**<br>**115VAC**<br>**--**<br>**25**<br>**--**<br>**230VAC**<br>**--**<br>**45**<br>**--**<br>**Leakage** **Current**<br>**264VAC**<br>**0.25mA** **RMS** **max.**<br>~~ne~~<br>~~)~~<br>~~———— —~~<br>~~eee~~<br>~~PT~~<br>~~a~~||||| ||**Hot** **Plug**||**Unavailable**|| |||||| ||**Output** **Specifications**|||| ||**Item**|**Operating** **Conditions**|**Min.**<br>**Typ.**<br>**Max.**|**Unit**| ||**Output** **Voltage** **Accuracy**|**0%** **-** **100%** **load**|**--**<br>**±2**<br>**--**|| ||**Line** **Regulation**|**Rated** **load**|**--**<br>**±0.5**<br>**--**|**%**| ||**Load** **Regulation**|**230VAC**|**--**<br>**±1.5**<br>**--**|| |||**5V** **output**|**--**<br>**--**<br>**80**|| |||**12V** **output**|**--**<br>**--**<br>**120**|| ||**Output** **Ripple** **&** **Noise***|**20MHz** **bandwidth**<br>**(peak-to-peak** **value)**<br>**15V** **output**|**--**<br>**--**<br>**120**|**mV**| |||**24V** **output**|**--**<br>**--**<br>**150**|| |||**48V** **output**|**--**<br>**--**<br>**240**|| **2021.07.25-A/1 Page 1 of 4** **W: www.TigerPowerSupplies.com E: info@TigerPowerSupplies.com T: +44 (0) 1491 522 711** **DIN30-XX Series** ## **AC/DC Converter** |**DIN30-XX** **Series**<br>ROITIGER|**DIN30-XX** **Series**<br>ROITIGER|**DIN30-XX** **Series**<br>ROITIGER| |---|---|---| |**Temperature** **Coefficient**<br>**--**<br>**±0.02**<br>**--**<br>**%/**°**C**<br>~~a~~||| |**Short** **Circuit** **Protection**<br>**Hiccup,** **continuous,** **self-recovery**<br>~~a~~||| |**Over-current** **Protection**<br>≥**120** **%** **Io,** **self-recovery**<br>~~a~~||| ||**5V** **output**<br>≤**7.5V**<br>~~oo~~|| ||**12V** **output**<br>≤**16V**<br>~~oo~~|| |**Over-voltage** **Protection**|**Output** **voltage** **clamp** **or** **hiccup**<br>**15V** **output**<br>≤**20V**<br>~~oo~~|| ||**24V** **output**<br>≤**36V**<br>~~oO~~|| ||**48V** **output**<br>≤**60V**<br>~~a~~|| |**Minimum** **Load**<br>~~a~~|**0**<br>**--**<br>**--**|**%**| |**Start-up** **Time**<br>~~a~~|**--**<br>**--**<br>**3**|**s**| |**Hold-up** **Time**<br>**115VAC**<br>**--**<br>**12**<br>**--**<br>**ms**<br>**230VAC**<br>**--**<br>**60**<br>**--**<br>~~ys}~~<br>~~a~~||| |**Note:** ***The** **“parallel** **cable”** **method** **is** **used** **for** **ripple** **and** **noise** **test,** **please** **refer** **to** **AC-DC** **Converter** **Application** **Notes** **for** **specific** **information.**<br>~~PE~~||| |||| |**General** **Specifications**||| |**Item**<br>**Operating** **Conditions**<br>**Min.**<br>**Typ.**<br>**Max.**<br>**Unit**<br>~~SS~~||| |**Isolation**<br>**Input** **-** **output**<br>**Electric** **Strength** **Test** **for** **1min.,**<br>**(leakage** **current**<**5mA)**<br>**4000**<br>**--**<br>**--**<br>**VAC**<br>**Operating** **Temperature**<br>**-40**<br>**--**<br>**+70**<br>℃<br>**Storage** **Temperature**<br>**-40**<br>**--**<br>**+85**<br>**Storage** **Humidity**<br>**--**<br>**--**<br>**95**<br>**%RH**<br>**Operating** **Altitude**<br>**--**<br>**--**<br>**2000**<br>**m**<br>**Switching** **Frequency**<br>**--**<br>**65**<br>**--**<br>**kHz**<br>**Power** **Derating**<br>**-40**℃ **to** **-30**℃<br>**5V/48V** **output**<br>**3.0**<br>**--**<br>**--**<br>**%/**℃<br>**12V/15V** **output**<br>**7.0**<br>**--**<br>**--**<br>**24V** **output**<br>**5.0**<br>**--**<br>**--**<br>~~arq~~<br>~~ee~~<br>~~ee~~<br>~~i~~<br>~~ee~~<br>~~ee~~<br>~~pr~~<br>~~eS~~||| ||**+50**℃ **to** **+70**℃<br>**2.5**<br>**--**<br>**--**<br>~~ee~~|| ||**85VAC** **-** **100VAC**<br>**1.0**<br>**--**<br>**--**<br>**%/VAC**<br>~~ee~~|| ||**UL/IEC62368-1,** **IS13252** **(Part1)** **safety** **approved** **&**|| |**Safety** **Standard**|**EN62368-1,** **BS** **EN** **62368-1** **(Report);**|| ||**Design** **refer** **to** **EN61558-1**|| |**Safety** **Class**|**CLASS** **I** **I**|| |**MTBF**<br>~~i~~|**MIL-HDBK-217F@25**°**C**<br>**> 300,000** **h**|| |||| |**Mechanical** **Specifications**||| |**Case** **Material**|**Plastic,** **heat-resistant** **(UL94V-0)**|| |**Package** **Dimensions**|**92.66** **x** **35.00** **x** **58.00mm**|| |**Weight**|**115g** **(Typ.)**|| |**Cooling** **method**|**Free** **air** **convection**|| ## **Electromagnetic Compatibility (EMC)** |**Electromagnetic** **Compatibility** **(EMC)**|**Electromagnetic** **Compatibility** **(EMC)**|**Electromagnetic** **Compatibility** **(EMC)**| |---|---|---| |**Emissions**|**CE**|**CISPR32/EN55032** **CLASS** **B**| ||**RE**|**CISPR32/EN55032** **CLASS** **B**| |**Immunity**|**ESD**|**IEC/EN61000-4-2**<br>**Contact** **±6KV/Air** **±8KV**<br>**Perf.** **Criteria** **A**| ||**RS**|**IEC/EN61000-4-3**<br>**10V/m**<br>**Perf.** **Criteria** **A**| ||**EFT**|**IEC/EN61000-4-4**<br>**±2KV**<br>**Perf.** **Criteria** **A**| ||**Surge**|**IEC/EN61000-4-5**<br>**line** **to** **line** **±2KV**<br>**Perf.** **Criteria** **A**| ||**CS**|**IEC/EN61000-4-6**<br>**10Vr.m.s**<br>**Perf.** **Criteria** **A**| ||**Voltage** **dips,** **short** **interruptions** **and**<br>**voltage** **variations** **immunity**|**IEC/EN61000-4-11** **100%** **dip** **1** **periods,** **30%** **dip** **25** **periods,**<br>**100%** **interruptions** **250** **periods**<br>**Perf.** **Criteria** **A**| **2021.07.25-A/1 Page 1 of 4** **W: www.TigerPowerSupplies.com E: info@TigerPowerSupplies.com T: +44 (0) 1491 522 711** ## **AC/DC Converter DIN30-XX Series Product Characteristic Curve** **Note:** ① **With an AC input between 85-100VAC and a DC input between 120-140VDC, the output power must be derated as per temperature derating curves;** - ② **This product is suitable for applications using natural air cooling; for applications in closed environment please consult factory or one of our FAE.** ## Efficiency Vs Output Load (Vin=230VAC) **(Vin=230VAC)** ## **Dimensions and Recommended Layout** **2021.07.25-A/1 Page 1 of 4 W: www.TigerPowerSupplies.com E: info@TigerPowerSupplies.com T: +44 (0) 1491 522 711** **AC/DC Converter DIN30-XX Series** ## **Note:** **1. For additional information on Product Packaging please refer to www.TigerPowerSupplies.com** **2. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25** ℃ **, humidity<75% with nominal input voltage and rated output load;** **3. All index testing methods in this datasheet are based on our company corporate standards;** **4. We can provide product customization service, please contact our technicians directly for specific information;** **5. Specifications are subject to change without prior notice.** **6. Products are related to laws and regulations: see "Features" and "EMC";** **7. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by qualified units.** **2021.07.25-A/1 Page 1 of 4** **W: www.TigerPowerSupplies.com E: info@TigerPowerSupplies.com T: +44 (0) 1491 522 711**
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →