Image not available
Illustrative purposes only
DIC01DB23AV0
INDUSTRIAL RELAYS 115-230VAC PROCES
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type: Signal Relays
- SVHC: No SVHC (21-Jan-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 202.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01** - **TRMS AC/DC over + under, over+over, under+under current and voltage monitoring relays** Vv - **DC process signal plus/minus monitoring relay (DIC01)** - **Selection of measuring range by DIP-switches** - **Adjustable current and voltage on relative scale** - **Adjustable hysteresis on relative scale** - **Separately adjustable delay functions (0.1 to 30 s)** - **Programmable latching or inhibit at set level** - **Output: 1 or 2 x 8 A SPDT relay N.D. or N.E. selectable** - **For mounting on DIN-rail in accordance with DIN/EN 50 022 (DIC01) or plug-in module (PIC01)** **==> picture [154 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> DIC01 PIC01<br>**----- End of picture text -----**<br> - **45 mm Euronorm housing (DIC01) or 36 mm plug-in module (PIC01)** - **LED indication for relay(s), alarm and power supply ON** - **Galvanically separated power supply** ## **Product Descri tion p** DIC01 and PIC01 are precise TRMS AC/DC over+under, over+over or under+under current and voltage (selectable by DIPswitch) monitoring relays. DIC01 can perform also DC plus/minus measurement by short circuiting pins Z3 and Y1. The devices can be connected to the MI or MP and A82 or E83 current transformers. own time delay. Only for DIC01 each set level can work with a single SPDT relay. Owing to the built-in latch function, the ON-position of the relay output can be maintained. Inhibit function can be used to avoid relay operation when not desired (maintenance, transitions). The LED's indicate the state of the alarm and the output relays. Both relays have two individual set levels with their ## **Orderin Ke g y** **Housing Function Type Item number Output Power supply Range** ## **DIC 01 D B23 AV0** ## **T e Selection yp** |**Mounting**|**Output**|**Supply: 24 to 48 VAC/DC Supply: 115/230 VAC**| |---|---|---| |DIN-rail|2xSPDT|**DIC 01 D D48 AV0 DIC 01 D B23 AV0**| |Plug-in|SPDT|**PIC 01 C D48 AV0 PIC 01 C B23 AV0**| ## **Supply: 24 to 48 VAC/DC Supply: 115/230 VAC** ## **In ut S ecifications p p** **Input** Current level DIC01: Terminals Y1, Y2 PIC01: Terminals 6, 7 Voltage level DIC01: Terminals Y1, Y3 PIC01: Terminals 5, 7 DC levels (DIC01 only) Connecting terminals Z3, Y1 **Measuring current ranges** Direct **Internal resis. Max. curr.** Selectable by DIP-switch 0.5 to 5 mA AC/DC 50 Ω 35 mA 2 to 20 mA AC/DC 50 Ω 55 mA -5 to 5 mA DC (DIC01 50 Ω 35 mA -20 to 20 mA DC} only) 50 Ω 55 mA Max. current for 1 s 100 mA **Measuring voltage ranges** Direct **Internal resis. Max. volt.** Selectable by DIP-switch 0.1 to 1 V AC/DC > 10 kΩ 7 V 1 to 10 V AC/DC > 10 kΩ 20 V 0.4 to 4 Vp AC > 10 kΩ 100 V -1 to 1 VDC (DIC01 > 10 kΩ 7 V -10 to 10 VDC } only) > 10 kΩ 20 V Max. voltage for 1 s 100 V ## **Note 1:** The input voltage cannot raise over 300 VAC/DC with respect to ground (PIC01 only) **1** Specifications are subject to change without notice (26.05.10) **DIC01, PIC01** ## **Input Specifications (cont.)** |**CT ranges**|**AAC rms**|**Max. curr.**| |---|---|---| |MI and MP ranges (0.4 to 4 Vpinput)||| |1-ph.:<br>3-ph.:||| |MI 5<br>MP 3005|0.5 to 5 A|20 AAC| |MI 20<br>MP 3020|2 to 20 A|50 AAC| |MI 100<br>MP 3100|10 to 100 A|250 AAC| |MI 500<br>MP 3500|50 to 500 A|750 AAC| |**Note 2:**||| |MP 3... current transformers<br>not suitable for under current<br>measurements due to the<br>output signal of the device||| |(see data sheet)||| |**CT ranges (cont.)**<br>A82 ranges (2 to 20 mA input)|**AAC rms**|**Max. curr.**| |A82-10/20 25|2.5 to 25 A|30 AAC| |A82-10/20 50<br>A82-10/20 100|5 to 50 A<br>10 to 100 A|60 AAC<br>120 AAC| |A82-10/20 250<br>A82-10/20 500<br>E83 ranges (2 to 20 mA input)<br>E83-20 50|25 to 250 A<br>50 to 500 A<br>5 to 50 A|300 AAC<br>600 AAC<br>100 AAC| |**Contact input**||| |DIC01|Terminals Z1,|Y1| |PIC01|Terminals 8, 9|| |Disabled|> 10 kΩ|| |Enabled|< 500Ω|| |Latch disable|> 500 ms|| ## **Out ut S ecifications p p** |**Output**||1 or 2 x SPDT relays| |---|---|---| |Rated insulation voltage||250 VAC| |**Contact ratings**(AgSnO2)||µ| |Resistive loads|AC 1|8 A @ 250 VAC| ||DC 12|5 A @ 24 VDC| |Small inductive loads|AC 15|2.5 A @ 250 VAC| ||DC 13|2.5 A @ 24 VDC| |**Mechanical life**||≥30 x 106 operations| |**Electrical life**||≥105 operations| |||(at 8 A,250 V,cosϕ= 1)| |**Operating frequency**||≤7200 operations/h| |**Dielectric strength**||| |Dielectric voltage||≥2 kVAC (rms)| |Rated impulse withstand volt.||4 kV (1.2/50 µs)| ## **Su l S ecifications pp y p** |**Power supply**||Overvoltage cat. III| |---|---|---| |Rated operational|voltage|(IEC 60664, IEC 60038)| |through terminals:||| |A1, A2 or A3, A2|(DIC01)|| |2, 10 or 11, 10|(PIC01)|| ||D48:|24 to 48 VAC/DC ± 15%| |||45 to 65 Hz, insulated| ||B23:|115/230 VAC ± 15%| |||45 to 65 Hz,insulated| |**Dielectric voltage**||**DC supply**<br>**AC supply**| |Supply to input||2 kV<br>4 kV| |Supply to output||4 kV<br>4 kV| |Input to output||4 kV<br>4 kV| |**Rated operational**|**power**|| |AC||5 VA| |DC||3 W| ## **General S ecifications p** |**Power ON delay**<br>**Reaction time**|1 s ± 0.5 s or 6 s ± 0.5 s<br>(input signal variation from<br>-20% to +20% or from| |---|---| ||+20% to -20% of set value)| |Alarm ON delay|< 100 ms| |Alarm OFF delay|< 100 ms| |**Accuracy**|(15 min warm-up time)| |Temperature drift|± 1000 ppm/°C| |Delay ON alarm|± 10% on set value ± 50 ms| |Repeatability<br>**Indication for**<br>Power supply ON<br>Alarm ON<br>Output relayON<br>**Environment**<br>Degree of protection<br>Pollution degree|± 0.5% on full-scale<br>LED, green<br>LED, red (flashing 2 Hz<br>during delay time)<br>1 or 2 x LED(s), yellow<br>(EN 60529)<br>IP 20<br>3 (DIC01), 2 (PIC01)| |Operating temperature|-20 to 60°C, R.H. < 95%| |Storage temperature|-30 to 80°C, R.H. < 95%| |**Housing**||| |---|---|---| |Dimensions|DIC01|45 x 80 x 99.5 mm| ||PIC01|36 x 80 x 94 mm| |Material||PA66 or Noryl| |**Weight**||Approx. 250g| |**Screw terminals**||| |Tightening torque||Max. 0.5 Nm| |||acc. to IEC 60947| |**Product standard**||EN 60255-6| |**Approvals**||UL,CSA| |**CE Marking**||L.V. Directive 2006/95/EC| |||EMC Directive 2004/108/EC| |EMC||| |Immunity||According to EN 60255-26| |||According to EN 61000-6-2| |Emissions||According to EN 60255-26| |||According to EN 61000-6-3| **2** Specifications are subject to change without notice (26.05.10) **DIC01, PIC01** ## **Mode of O eration p** DIC01 and PIC01 monitor both AC and DC current and voltage. DIC01 can also monitor positive and negative DC voltage connecting terminals Y1 and Z3. ## **Example 1** (no contact input - under+over voltage - 2 x SPDT N.D. relays (1 x SPDT for PIC01) - TRMS) DIC01: One relay operates when the voltage drops below the under voltage set point for more than the respective delay time. It releases when the voltage exceeds the set level plus the set hysteresis. The other relay operates when the voltage exceeds the over voltage set point for more than the respective delay time. It releases when the voltage drops below the set level minus hysteresis. PIC01: The relay operates when the voltage drops below the under voltage set level for more than the respective set delay time or when it exceeds the over voltage set level for more than the relative set delay time. The relay releases when the voltage exceeds the under voltage set level plus hysteresis and it drops below the over voltage set level minus hysteresis (the hysteresis is the same for both set levels). ## **Example 2** (latch enable active - under+under current - 2 x SPDT relays (1 x SPDT for PIC01) - TRMS) DIC01: Each relay operates and latches when the current drops below the respective set level for more than the respective delay time. Provided that the current has exceeded the respective set level plus hysteresis, each relay releases when the contact input’s connection is interrupted. PIC01: The relay operates when the current drops below the higher set level for more than the respective delay time. Provided that the current has exceeded the higher set level plus hysteresis the relay releases when the contact input’s connections is interrupted. ## **Note** Different delay times can be used for appropriate reaction according to the set points. ## **Example 3** (inhibit enable active - over+over current with MI CT - DPDT relay (SPDT for PIC01) - TRMS) Provided that the contact input’s connection is interrupted, the relay operates when the current flowing in the MI CT exceeds the lower set level for more than the respective delay time. It releases when the current drops below the lower set level minus hysteresis or when the contact input’s pins are connected. ## **Example 4** (inhibit enable active - over+over current with A8210 CT - DPDT relay (1 x SPDT for PIC01) - TRMS Provided that the contact input’s connection is interrupted, the relay operates when the current flowing in the A82-10 CT exceeds the lower set level for more than its delay time. It releases when the current drops below the lower set level minus hysteresis or when the contact input’s pins are connected. ## **Example 5 (DIC01 only)** (no contact input - under+over voltage - 2 x SPDT N.D. relays - plus/minus DC One relay operates when the voltage drops below the under voltage set point for more than the respective delay time. It releases when the voltage exceeds the set level plus the set hysteresis. The other relay operates when the voltage exceeds the over voltage set point for more than the respective delay time. It releases when the voltage drops below the set level minus hysteresis. In this case the spare front label has to be placed on the device for proper level adjustment. ## **Note** When the inhibit contact is opened, if the input signal is already in alarm position, the delay time needs to elapse before relay(s) activation. **3** Specifications are subject to change without notice (26.05.10) **DIC01, PIC01** ## **Function/Range/Level and Time Delay Setting** Adjust the input range setting the DIP switches 1 and 2 of the main black selector as shown below. Select the desired function setting the DIP switches 3 to 6 of the black selector and 1, 2 of the small red selector as shown below. To access the DIP switches open the grey plastic cover as shown below The selection between current and voltage is automatically selected through the input connectors. TRMS or positive/negative DC monitoring selectable by short-circuiting terminals Y1 and Z3 (DIC01 only). **Set Point 2 (SP2) monitoring function** ON: Over current or voltage OFF: Under current or voltage **Relay(s) coupling** ON: 2 x SPDT (DIC01 only) OFF: 1 x DPDT (DIC01, PIC01) ## **Selection of level, time** ## **delay and hysteresis:** ## **Upper knob:** Setting of hysteresis on relative scale: 0 to 30% on set value. **Centre knobs:** ## **Lower knobs:** Current level setting on relative scale: 10 to 110% on full scale. Setting of delay on alarm time on absolute scale (0.1 to 30 s). |**Measuring range (depending on connections)**|**Measuring range (depending on connections)**|**Measuring range (depending on connections)**|**Measuring range (depending on connections)**| |---|---|---|---| |SW1<br>ON<br>Connect Input term.<br>SW2<br>OFF||ON<br>ON|OFF<br>ON| |None<br>DIC01: Y1,Y2<br>0.5 to 5 mA <br>PIC01: 5,7<br>AC/DC|2 to 20 mA|2 to 20 mA<br>AC/DC|None| |Y1 to Z3 DIC01: Y1,Y2<br>-5 to +5|-20 to +20||None| |mA DC<br>None<br>DIC01: Y1,Y3<br>0.1 to 1V<br>PIC01: 6,7<br>AC/DC<br>Y1 to Z3 DIC01: Y1,Y3<br>-1 to +1||mA DC<br>4 Vp<br>None|1 to 10 V<br>AC/DC<br>-10 to +10| |V DC|||V DC| |**Relay(s) working mode**<br>ON: Normally De-energized (ND)<br>OFF: Normally Energized (NE)<br>**Power ON delay**<br>ON: 6 s ± 0.5 s<br>OFF: 1 s ± 0.5 s<br>**Contact input**<br>~~ee~~|||| |ON: Latch function enable|||| |OFF: Inhibit function enable|||| |**Set Point 1 (SP1) monitoring function**<br>ON: Over current or voltage|||| |OFF: Under current or voltage|||| ## **O eration Dia rams p g** ~~—~~ **Over+over voltage/current - N.D. relay(s)** **==> picture [423 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> ent - N.D. relay(s)t - N.D. relay(s) Over+over voltage/current - Latch - N.D. relay(s)<br>Power Supply<br>A \ J~X LatchON 0<br> — -— _ —- Set Level 1 Al IN.<br>Hysteres is— — —— —,<br>NS cate<br>1 1<br>toré6s,; }T T 2 4 T 2 HT 4 Hysteresis — — 1 — — —\— Sf 1<br>lorés}~ | tT rE n0010601) lorés, FT |_____ ——<br>2 2<br> HFS S/T }|__ \T _——-RE2(DIC02) jtorés}—T |__§__. Ta<br>**----- End of picture text -----**<br> **4** ~~Specifications are subject to change without notice (26.05.10)~~ **DIC01, PIC01** ## **Operation Diagrams (cont.)** **Over+under voltage/curr** ~~**e**~~ **nt - N.E. relay(s)** **Over+under voltage/curr** ~~**en**~~ **t - Inh** ~~**ib**~~ **it - N.E. relay(s)** **==> picture [246 x 34] intentionally omitted <==** **----- Start of picture text -----**<br> 1 1<br>2<br>**----- End of picture text -----**<br> **==> picture [245 x 39] intentionally omitted <==** **----- Start of picture text -----**<br> 1 1<br>2<br>1 2 1<br>**----- End of picture text -----**<br> **Under+under voltage/current - N.D. relay(s)** **==> picture [246 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> 1 1<br>2<br>**----- End of picture text -----**<br> ## **Wiring Diagrams** **==> picture [500 x 250] intentionally omitted <==** **----- Start of picture text -----**<br> 24÷48 VAC/DC<br>230VAC 115VAC 24÷48 VAC/DC<br>230VAC 115VAC<br>24÷48 VAC/DC<br>2 30VA C 115VAC<br>24÷48 VAC/DC<br>230VAC 115VAC 24÷48 VAC/DC<br>230VAC 115VAC<br>DIC01 PIC01<br>**----- End of picture text -----**<br> **5** Specifications are subject to change without notice (26.05.10) **DIC01, PIC01** ## **Wiring Diagrams (cont.)** **==> picture [500 x 391] intentionally omitted <==** **----- Start of picture text -----**<br> 24÷48 VAC/DC 24÷48 VAC/DC<br>230VAC 115VAC 230VAC 115VAC<br>24÷48 VAC/DC 24÷48 VAC/DC<br>230VAC 115VAC 230VAC 115VAC<br>24÷48 VAC/DC<br>230VAC 115VAC<br>DIC01 PIC01<br>**----- End of picture text -----**<br> ## **Dimensions** **==> picture [244 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> DIN-rail<br>45 99.5<br>28.5<br>80 83.5 63<br>**----- End of picture text -----**<br> **==> picture [245 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> Plug-in<br>94<br>36 90<br>28.5<br>80 63<br>**----- End of picture text -----**<br> **6** Specifications are subject to change without notice (26.05.10)
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →