Motor Starter, Variable Speed, Power XL, DE1 Series, 7.5 kW, 16 A, 400 to 480 Vac
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON MOELLER
- Product type: Motor Starters
- Supply Voltage Min:380VAC; Supply Voltage Max:480VAC; No. of Phases:Three Phase; Power Rating:7.5kW; Current Rating:16A; Product Range:PowerXL DE1 Series; SVHC:No SVHC (15-Jan-2018)
- SVHC: No SVHC (17-Dec-2015)
- No. of Poles: 4 Pole
- Power Rating: 7.5kW
- No. of Phases: Three Phase
- Product Range: PowerXL DE1
- Current Rating: 16A
- IP / NEMA Rating: IP20
- Motor Starter Type: Variable Speed Starter
- Supply Voltage Max: 480VAC
- Supply Voltage Min: 380VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 727.56 € |
| Current stock | 10+ |
| Lead time | 30 days |
**DATASHEET - DE11-34016FN-N20N** **Speed starters, three-phase power supply connection, three-phase motor** **Part no. DE11-34016FN-N20N Catalog No. 180669 Eaton Catalog No. DE11-34016FN-N20N** |**Technical data**|**Technical data**|||| |---|---|---|---|---| |**General**||||| ||Standards|||Specification for general requirements: IEC/EN 61800-2<br>EMC requirements: IEC/EN 61800-3| |||||Safety requirements: IEC/EN 61800-5-1| ||Certifications|||CE, UL, cUL, RCM| ||Production quality|||RoHS, ISO 9001| ||Climatic proofing|ρw|%|< 95%, average relative humidity (RH), non-condensing, non-corrosive| ||Ambient temperature|||| ||operation (150 % overload)|ϑ|°C|-10 - +50| |||||Derating between 50 °C and 60 °C:| |||||None if fPWM≦ 14 kHz up to a max. of 50 °C| |||||None if fPWM≦ 16 kHz up to a max. of 46 °C| |||||None if Ie≦ 14.9 A and fPWM≦ 10 kHz| |||||None if Ie≦ 10.6 A and fPWM≦ 20 kHz| ||Storage|ϑ|°C|-40 - +70| ||Radio interference level|||| ||Radio interference class (EMC)|||C2, C3, depending on the motor cable length, the connected load, and ambient| |||||conditions. External radio interference suppression filters (optional) may be<br>necessary.| ||Environment (EMC)|||1st and 2nd environments as per EN 61800-3| ||maximum motor cable length|I|m|C2 ≤ 10 m| |||||C3 ≤ 25 m| ||Mechanical shock resistance||g|15 (11 m/s, EN 60068-2-27)| ||Vibration|||EN 61800-5-1| ||Altitude||m|0 - 1000 m above sea level| |||||Above 1000 m: 1% derating for every 100 m| |||||max. 2000 m| ||Degree of Protection|||IP20/NEMA 0| ||Protection against direct contact|||BGV A3 (VBG4, finger- and back-of-hand proof)| |**Main circuit**||||| ||Supply|||| ||Rated operational voltage|Ue||400 V AC, 3-phase| |||||480 V AC, 3-phase| ||Mains voltage (50/60Hz)|ULN|V|380 (-10%) - 480 (+10%)| ||Input current (150% overload)|ILN|A|16.5| ||Supply frequency|fLN|Hz|50/60| ||Frequency range|fLN|Hz|45 - 66| ||Mains switch-on frequency|||Maximum of one time every 30 seconds| ||Power section|||| ||Overload current (150% overload)|IL|A|24| ||max. starting current (High Overload)|IH|%|200| ||Note about max. starting current|||for 1.875 seconds every 600 seconds| ||Output voltage with Ve|U2||400 V AC, 3-phase| |||||480 V AC, 3-phase| ||Output Frequency|f2|Hz|0 - 50/60 (max. 300)| ||Switching frequency|fPWM|kHz|16| |||||adjustable 4 - 32 (audible)| ||Operation Mode|||U/f control| |||||Speed control with slip compensation| 05/10/2018 Eaton 180669 ED2018 V44.0 EN 1 / 5 |Frequency resolution (setpoint value)|Δf|Hz|0.03| |---|---|---|---| |Rated operational current|||| |At 150% overload|Ie|A|16| |Note|||Rated operational current at an operating frequency of 16 kHz and an ambient air<br>temperature of +50 °C| |Maximum leakage current to ground (PE) without motor|IPE|mA|< 3.5 AC, < 10 DC| |Fitted with|||Radio interference suppression flter| |Frame size|||<br>FS2| |Motor feeder|||| |Note|||for normal internally and externally ventilated 4 pole, three-phase asynchronous<br>motors with 1500 rpm-1at 50 Hz or 1800 min-1at 60 Hz| |Note|||Overload cycle for 60 s every 600 s| |Note|||at 400 V, 50 Hz| |150 % Overload|P|kW|7.5| |Note|||at 440 - 480 V, 60 Hz| |150 % Overload|P|HP|10| |Apparent power|||| |Apparent power at rated operation 400 V|S|kVA|11.09| |Apparent power at rated operation 480 V|S|kVA|13.3| |Braking function|||| |Standard braking torque|||max. 30 % MN| |DC braking torque|||adjustable to 100 %| |**Control section**|||| |Reference voltage|Us|V|10 V DC (max. 0.2 mA)| |Analog inputs|||1, parameterizable, 0 - 10 V DC, 0/4 - 20 mA| |Digital inputs|||4, parameterizable, 10 - 30 V DC| |Relay outputs|||1, parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1)| |Interface/feld bus (built-in)|||OP-Bus (RS485)/Modbus RTU, CANopen®| |**Assigned switching andprotective elements**|||| |Power Wiring|||| |Safety device (fuse or miniature circuit-breaker)|||| |IEC (Type B, gG), 150 %|||FAZ-B25/3| |UL (Class CC or J)||A|25| |Mains contactor|||| |150 % overload (CT/IH, at 50 °C)|||DILEM-…| |110 % overload (VT/IL, at 40 °C)|||DILM7-…| |Main choke|||| |150 % overload (CT/IH, at 50 °C)|||DX-LN3-016| |Motor feeder|||| |motor choke|||| |150 % overload (CT/IH, at 50 °C)|||DX-LM3-016| ||||| |**Design verifcation asper IEC/EN 61439**|||| |<br>Technical data for design verifcation|||| |<br>Rated operational current for specifed heat dissipation|In|A|16| |Heat dissipation per pole, current-dependent|Pvid|W|0| |Equipment heat dissipation, current-dependent|Pvid|W|240| |Static heat dissipation, non-current-dependent|Pvs|W|0| |Heat dissipation capacity|Pdiss|W|0| |Operating ambient temperature min.||°C|-10| |Operating ambient temperature max.||°C|60| ||||Operation (with 150 % overload), allow for derating| |IEC/EN 61439 design verifcation|||| |<br>10.2 Strength of materials and parts|||| |10.2.2 Corrosion resistance|||Meets the product standard's requirements.| 05/10/2018 Eaton 180669 ED2018 V44.0 EN 2 / 5 |10.2.3.1 Verifcation of thermal stability of enclosures|||Meets the product standard's requirements.| |---|---|---|---| |<br>10.2.3.2 Verifcation of resistance of insulating materials to normal heat|||Meets the product standard's requirements.| |<br>10.2.3.3 Verifcation of resistance of insulating materials to abnormal heat<br>and fre due to internal electric efects|||Meets the product standard's requirements.| |<br>10.2.4 Resistance to ultra-violet (UV) radiation|||Meets the product standard's requirements.| |10.2.5 Lifting|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.6 Mechanical impact|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.7 Inscriptions|||Meets the product standard's requirements.| |10.3 Degree of protection of ASSEMBLIES|||Does not apply, since the entire switchgear needs to be evaluated.| |10.4 Clearances and creepage distances|||Meets the product standard's requirements.| |10.5 Protection against electric shock|||Does not apply, since the entire switchgear needs to be evaluated.| |10.6 Incorporation of switching devices and components|||Does not apply, since the entire switchgear needs to be evaluated.| |10.7 Internal electrical circuits and connections|||Is the panel builder's responsibility.| |10.8 Connections for external conductors|||Is the panel builder's responsibility.| |10.9 Insulation properties|||| |10.9.2 Power-frequency electric strength|||Is the panel builder's responsibility.| |10.9.3 Impulse withstand voltage|||Is the panel builder's responsibility.| |10.9.4 Testing of enclosures made of insulating material|||Is the panel builder's responsibility.| |10.10 Temperature rise|||The panel builder is responsible for the temperature rise calculation. Eaton will<br>provide heat dissipation data for the devices.| |10.11 Short-circuit rating|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |10.12 Electromagnetic compatibility|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |10.13 Mechanical function|||The device meets the requirements, provided the information in the instruction<br>leafet (IL) is observed.| ## **Technical data ETIM 6.0** Low-voltage industrial components (EG000017) / Frequency converter =< 1 kV (EC001857) |**Technical data ETIM 6.0**|**Technical data ETIM 6.0**|**Technical data ETIM 6.0**|**Technical data ETIM 6.0**| |---|---|---|---| |Low-voltage industrial components (EG000017) / Frequency converter =< 1 kV (EC001857)|||| |Electric engineering, automation, process control engineering / Electrical drive / Static frequency converter / Static frequency converter = < 1 kv (ecl@ss8.1-27-02-31-01 [AKE177011])|||| |Mains voltage||V|380 - 480| |Mains frequency|||50/60 Hz| |Number of phases input|||3| |Number of phases output|||3| |Max. output frequency||Hz|300| |Max. output voltage||V|500| |Rated output current I2N||A|16| |Max. output at quadratic load at rated output voltage||kW|0.5| |Max. output at linear load at rated output voltage||kW|0.5| |With control unit|||No| |Application in industrial area permitted|||Yes| |Application in domestic- and commercial area permitted|||Yes| |Supporting protocol for TCP/IP|||No| |Supporting protocol for PROFIBUS|||No| |Supporting protocol for CAN|||No| |Supporting protocol for INTERBUS|||No| |Supporting protocol for ASI|||No| |Supporting protocol for KNX|||No| |Supporting protocol for MODBUS|||Yes| |Supporting protocol for Data-Highway|||No| |Supporting protocol for DeviceNet|||No| |Supporting protocol for SUCONET|||No| |Supporting protocol for LON|||No| |Supporting protocol for PROFINET IO|||No| |Supporting protocol for PROFINET CBA|||No| |Supporting protocol for SERCOS|||No| |Supporting protocol for Foundation Fieldbus|||No| 05/10/2018 Eaton 180669 ED2018 V44.0 EN 3 / 5 |Supporting protocol for EtherNet/IP|||Yes| |---|---|---|---| |Supporting protocol for AS-Interface Safety at Work|||No| |Supporting protocol for DeviceNet Safety|||No| |Supporting protocol for INTERBUS-Safety|||No| |Supporting protocol for PROFIsafe|||No| |Supporting protocol for SafetyBUS p|||No| |Supporting protocol for other bus systems|||Yes| |Number of HW-interfaces industrial Ethernet|||0| |Number of HW-interfaces PROFINET|||0| |Number of HW-interfaces RS-232|||0| |Number of HW-interfaces RS-422|||0| |Number of HW-interfaces RS-485|||1| |Number of HW-interfaces serial TTY|||0| |Number of HW-interfaces USB|||0| |Number of HW-interfaces parallel|||0| |Number of HW-interfaces other|||0| |With optical interface|||No| |With PC connection|||No| |Integrated breaking resistance|||No| |4-quadrant operation possible|||No| |Type of converter|||U converter| |Degree of protection (IP)|||IP20| |Height||mm|230| |Width||mm|90| |Depth||mm|168| |Relative symmetric net frequency tolerance||%|5| |Relative symmetric net current tolerance||%|10| ## **Approvals** |**Approvals**|||| |---|---|---|---| |Product Standards|||UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking| |UL File No.|||E172143| |UL Category Control No.|||NMMS, NMMS7| |CSA File No.|||UL report applies to both US and Canada| |North America Certifcation|||UL listed, certifed by UL for use in Canada| |<br>Specially designed for North America|||<br>No| |Suitable for|||Branch circuits| |Max. Voltage Rating|||3~ 480 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey)| |Degree of Protection|||IEC: IP20| 05/10/2018 Eaton 180669 ED2018 V44.0 EN 4 / 5 **Dimensions** Eaton Industries GmbH http://www.eaton.eu © 05/2018 by Eaton Industries GmbH Eaton 180669 ED2018 V44.0 EN 05/10/2018 5 / 5
Updated at March 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →