- Manufacturer: SENSATA/CRYDOM
- Product type:
- Contact Configuration:SPST-NC; Load Current:7A; Operating Voltage Max:60VDC; Relay Mounting:Panel; Relay Terminals:Screw Clamp; Switching Mode:DC Switch; Operating Voltage Min:3VDC; Control Voltage Min:3.
- Load Current: 7A
- Product Range: DC60 Series
- Relay Mounting: Panel Mount
- Switching Mode: DC Switch
- Relay Terminals: Screw Clamp
- Control Voltage Max: 32VDC
- Control Voltage Min: 3.5VDC
- Contact Configuration: SPST-NC
- Operating Voltage Max: 60VDC
- Operating Voltage Min: 3VDC
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 48.56 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **| DC60 SERIES** ## PANEL MOUNT ## Features - Ratings from 3A to 7A @ 60 VDC - Bi-Polar Transistor Output - UL Approved, CE Compliant to EN60950-1 - Improved SEMS Screw and Washer - Redesigned Housing with Anti-Rotation Barriers - AC and DC Control - Epoxy Free Design ## **PRODUCT SELECTION** |**Control Voltage**|**3A**|**5A**|**7A**| |---|---|---|---| |**3.5-32 VDC**|DC60S3|DC60S5|DC60S7| |**90-280 VAC/VDC**|DC60SA3|DC60SA5|DC60SA7| ## **SPECIFICATIONS** ## Output **[(2)]** |**Description**|**3A**|**5A**|**7A**| |---|---|---|---| |**Recommended Operating Voltage [Vdc]**|3-48|3-48|3-48| |**Absolute Maximum Rating [Vdc]**|60|60|60| |**Maximum Off-State Leakage Current**<br>**@ Rated Voltage [mA]**|0.1|0.1|0.1| |**Maximum Load Current [Adc](3)**|3|5|7| |**Minimum Load Current [mA]**|20|20|20| |**Maximum Surge Current (10 msec) [Adc]**|6|10|14| |**Maximum On-State Voltage Drop**<br>**@ Rated Current [Vdc]**|1|1.2|1.3| |**Thermal Resistance Junction to Case**<br>**(Rjc) [**°**C/W]**|2|2|2| |**Minimum Heat Sink @ Ambient**<br>**(for max current = °C/W & Ta)**|5 @ 60°C|5 @ 60°C|5 @ 40°C| Page 1 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## Input **[(2)]** **==> picture [541 x 160] intentionally omitted <==** **----- Start of picture text -----**<br> Description DC Control AC Control<br>Control Voltage Range 3.5-32 VDC 90-280 VAC/VDC<br>Maximum Reverse Voltage -32 VDC —<br>Minimum Turn-On Voltage [(4)] 3.5 VDC 90 VAC/VDC<br>Must Turn-Off Voltage [(5)] 1 VDC 10 VAC/VDC<br>Minimum Input Current (For On-State) 2.2 mA 2 mA<br>Maximum Input Current 25 mA 5.5 mA<br>Nominal Input Impedance [Ohms] 1500 Ohm 60K<br>Maximum Turn-On Time [msec] [(6)] 0.1 10<br>Maximum Turn-Off Time [msec] [(7)] 0.3 40<br>**----- End of picture text -----**<br> ## General **[(2)]** **==> picture [541 x 355] intentionally omitted <==** **----- Start of picture text -----**<br> Description Parameters<br>Dielectric Strength, Input/Output/Base<br>4000 Vrms<br>(50/60Hz) [(2)]<br>Minimum Insulation Resistance<br>10 [9] Ohm<br>(@500 VDC) [(2)]<br>Maximum Capacitance, Input/Output 8 pF<br>Ambient Operating Temperature Range -30 to 80°C<br>Ambient Storage Temperature Range -40 to 125°C<br>Weight (typical) 2.46 oz. (17g)<br>Housing Material UL94 V-0<br>Baseplate Material Aluminum<br>Input Terminal Screw Torque Range<br>13-15 / 1.5-1.7<br>(in/lb/NM)<br>Load Terminal Screw Torque Range<br>18-20 / 2-2.2<br>(in/lb/NM)<br>SSR Mounting Screw Torque Range<br>18-20 / 2-2.2<br>(in-lb/Nm)<br>Input/Load Terminal Screw Torque Range<br>13-15 / 1.5-1.7<br>(in/lb/NM) [(1)]<br>Humidity 85% non-condensing<br>MTBF (Mean Time Between Failures)<br>at 40 ° C Ambient Temperature [(8)] 21,395,130 hours (2,441 years)<br>MTBF (Mean Time Between Failures)<br>at 60 ° C Ambient Temperature [(8)] 11,545,504 hours (1,317 years)<br>**----- End of picture text -----**<br> Page 2 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## **WIRING DIAGRAM** * Inductive loads must be diode suppressed. **==> picture [84 x 172] intentionally omitted <==** **==> picture [85 x 172] intentionally omitted <==** |**Recommended Wire Sizes**|**Recommended Wire Sizes**|**Recommended Wire Sizes**| |---|---|---| |**Terminals**|**Wire Size**<br>**(Solid / Stranded)**|**Wire Pull-Out**<br>**Strength (lb) [N]**| |**Input**|24 AWG (0.2 mm2) / 0.2 [minimum]|**10 [44.5]**| ||2 x 12 AWG (3.3 mm2) / 3.3 [maximum]|**90 [400]**| |**Output**|20 AWG (0.5 mm2) / 0.518 [minimum]|**30 [133]**| ||2 x 10 AWG (5.3 mm2) / 5.3|**110 [490]**| ||2 x 8 AWG (8.4 mm2)/ 8.4 [maximum]|**90 [400]**| ## **EQUIVALENT CIRCUIT BLOCK DIAGRAMS** **==> picture [243 x 87] intentionally omitted <==** **==> picture [248 x 84] intentionally omitted <==** **==> picture [170 x 205] intentionally omitted <==** Page 3 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## **MECHANICAL SPECIFICATIONS[(1)]** Tolerances: ±0.02 in / /0.5 mm All dimensions are in inches [millimeters] **==> picture [98 x 123] intentionally omitted <==** **==> picture [40 x 95] intentionally omitted <==** **==> picture [98 x 123] intentionally omitted <==** **==> picture [45 x 95] intentionally omitted <==** ## **SURGE CURRENT INFORMATION** **==> picture [505 x 232] intentionally omitted <==** Page 4 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## **THERMAL DERATE INFORMATION** (i) SSR metal base plate acting as heat sink, it must be exposed to free ambient air. **==> picture [165 x 114] intentionally omitted <==** **==> picture [165 x 114] intentionally omitted <==** **==> picture [166 x 114] intentionally omitted <==** **==> picture [541 x 295] intentionally omitted <==** **----- Start of picture text -----**<br> ORDERING OPTIONS Example : DC60SA3KH-B<br> Not all part number combinations are available.<br>Contact Sensata Technical Support for information on the availability of a specific part number.<br>DC60 - SA - 3 - K - H - -B<br>Family<br>DC60<br>Control Voltage<br>S: 3.5-32 VDC<br>SA: 90-280 VAC/DC<br>Rated Load Current<br>3: 3 Amps<br>5: 5 Amps<br>7: 7 Amps<br>Termination<br>Blank: Screws & clamps<br>K: Installed standoffs with screws for PC Board mounting [(1)]<br>Thermal Pad<br>Blank: Not Included<br>H: Included<br>Output Type<br>**----- End of picture text -----**<br> Required for valid part number For options only and not required for valid part Page 5 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. **ACCESSORIES** **New Accessories!** Protective Cover and Hardware Kits ~~ee~~ **Protective Cover Hardware Kit** Part Number KS101 Part Number HK4 Clear plastic cover compatible with all new S1 Bag with 2 square brass accessories and 2 screw 8-32 designs. Safety covers provide added protection from x 5/8 for output. Used to mount TMR1 lug terminals. electric shock when installing or checking equipment. ~~es~~ **Recommended Accessories** ~~|~~ **Heat Sink Thermal Resistance Cover Hardware Kit Lug Terminal Thermal Pad Part No. [°C/W]** KS101 HK1 HS501DR 5.0 TRM1 HSP-1 HK4 HS301 / HS301DR 3.0 TRM6 HSP-2 HS251 2.5 HS201 / HS201DR 2.0 HS202 / HS202DR 2.0 HS172 1.7 HS151 / HS151DR 1.5 HS122 / HS122DR 1.2 HS103 / HS103DR 1.0 HS101 1.0 HS073 0.7 HS072 0.7 HS053 0.5 HS033 0.36 HS023 0.25 ~~LET~~ **GENERAL NOTES** © (1) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm). (2) All parameters at 25°C unless otherwise specified. (3) Heat sinking required, see derating curves. - (4) Maximum turn-on voltage for -B, DC control is 1 VDC. - (5) Must turn-off voltage for -B, DC control is 3.5 VDC. - (6) Turn-on time for -B version is 300μsec. - (7) Turn-off time for -B version is 100μsec. (8) All parameters at 50% power rating and 100% duty cycle (contact Sensata tech support for detailed report). - (9) For single surge pulse Tc=25°C; Tj=150°C. For additional information or specific questions, contact Sensata Technical Support. Page 6 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## **AGENCY APPROVALS & CERTIFICATIONS** - EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: - IEC 61000-4-2 Electrostatic Discharge Level 3 - IEC 61000-4-4 Electrically Fast Transients Level 3 - IEC 61000-4-5 Electrical Surges Level 3 - Vibration Resistance: IEC 60068-2-6 : Amplitude Range 10-55 Hz, Displacement 0.75mm - Shock Resistance: IEC 60068-2-27 : Peak Acceleration 15g, Duration11msec ## E116950 ## **WARNINGS** RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Page 7 Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (877) 502 5500 – Option 2 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. www.sensata.com Rev: 10/07/20 ECN 20981 FDE-07-01 Rev. B Copyright © 2020 Sensata Technologies, Inc.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →