DBR-3200-24
Battery Charger, Desktop, Front End, 3200 W, 30 V, Lead Acid, Li-Ion, DBR-3200 Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- Battery Charger Type:Desktop; Battery Technologies Supported:Lead Acid, Li-Ion; Supply Voltage:30V; Battery Size Code:-; Battery IEC Code:-; Battery NEDA Code:-; Product Range:DBR-3
- SVHC: No SVHC (25-Jun-2025)
- Plug Type: -
- Product Range: DBR-3200 Series
- Charge Current: 110A
- Output Voltage: 23.5V to 30V
- Supply Voltage: 30V
- Battery Size Code: -
- Battery Charger Type: Desktop
- No. of Cells Charged: -
- Battery Technologies Supported: Lead Acid, Li-Ion
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 557.66 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- DBR 3200 series** 3200W Rack Mountable Front End Battery Charger **==> picture [43 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> **==> picture [233 x 48] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>Parallel &® WA US ( A) EAL C B<br>UL62368-1 BS EN/EN62368-1 TPTC004 IEC62368-1<br>■<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [121 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> https://www.meanwell.com/serviceGTIN.aspx<br>**----- End of picture text -----**<br> ## ■ DBR-3200 is a 3200W single output AC/DC front-end charger in 1U low profile with high power density, 3 37W/inch . It is an intelligent charger that has pre-loaded programmable charging curves for different types of lead-acid and li-ion batteries. Output programmable function allows user to adjust the charging voltage and current via the built-in potentiometer or PMBus protocol. Various protection mechanisms as well as the temperature compensation function are provided to assure normal and safe system operation. The rack-mountable attribute fits DBR-3200 perfectly for the charging, backup or constant current source applications exploiting the rack architecture or central power management. ## ■ ## ※ _File Name:DBR-3200-SPEC 2022-12-05_ 3200W Rack Mountable Front End Battery Charger ## **- DBR 3200 series** ## **SPECIFICATION** |**DBR-3200-24**<br>**MODEL**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**AC CURRENT (Typ.)**<br>**Note.4**<br>28.8V<br>27.6V<br>110A<br>23.5 ~ 30V<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>0.97/230VAC at full load<br>COLD START 55A/230VAC<br>17A/230VAC<br><1.5mA / 230VAC<br>**DBR-3200-48**<br>57.6V<br>55.2V<br>55A<br>47.5 ~ 58.8V<br>93.5%<br>94.5%<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>31.5 ~ 37.5V<br>63 ~ 75V<br>**PROTECTION**<br>**REMOTE ON-OFF CONTROL**<br>By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual<br>**FUNCTION**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>**ENVIRONMENT**<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>UL62368-1, CSA C22.2<br>, TUV<br>EN62368-1, EAC TP TC 004 approved<br>BS EN/<br>No. 62368-1<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>**ISOLATION RESISTANCE**<br>**MTBF**<br>**DIMENSION**<br>**PACKING**<br>**OTHERS**<br>528.8K hrs min.<br>Telcordia SR-332 (Bellcore) ; 44.4K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>325*107*41mm (L*W*H)<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>2.65Kg;4pcs/11.6Kg/0.93CUFT<br>**NOTE**<br>**TEMPERATURE COMPENSATION** -3mV /<br>/ cell / (12V = 6 cells ; 24V = 12 cells ; 48V = 24 cells)<br>℃<br>**AUXILIARY POWER**<br>5V @ 0.3A, tolerance<br>10%, ripple 150mVp-p, 12V @ 0.8A, tolerance<br>10%, ripple 450mVp-p<br>±<br>±<br>**BOOST CHARGE VOLTAGE(Vboost)(default)**<br>**FLOAT CHARGE VOLTAGE(Vfloat)(default)**<br>By built-in potentiometer, SVR<br>**RECOMMENDED BATTERY**<br>**CAPACITY(AMP HOURS) Note.3** 330 ~ 1000Ah<br>18<br>550<br>0 ~<br>Ah<br>**LEAKAGE CURRENT FROM**<br>**BATTERY (Typ.)**<br><1.5mA<br>**CONSTANT CURRENT(CC)(default)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2<br>**Standard**<br>**Standard**<br>BS EN/EN55032 (CISPR32)<br>BS EN/EN55032 (CISPR32)<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-3<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class A<br>Class A<br>-----<br>Adjustment of output voltage is allowable to 75 ~ 125% of nominal output voltage. Please refer to the Function Manual.<br>Adjustment of output voltage is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.<br>**OUTPUT VOLTAGE PROGRAMMABLE(PV)**<br>**OUTPUT CURRENT PROGRAMMABLE(PC)**<br>**DC OK SIGNAL**<br>**AC OK SIGNAL**<br>The isolated TTL signal out. Please refer to the Installation Manual<br>The isolated TTL signal out. Please refer to the Installation Manual<br>℃<br>http://www.meanwell.com)<br>℃<br>℃<br>※<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>:<br>1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.<br>2. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25<br>of ambient temperature.<br>3. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. The charger is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**DBR-3200-24**<br>**MODEL**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**AC CURRENT (Typ.)**<br>**Note.4**<br>28.8V<br>27.6V<br>110A<br>23.5 ~ 30V<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>0.97/230VAC at full load<br>COLD START 55A/230VAC<br>17A/230VAC<br><1.5mA / 230VAC<br>**DBR-3200-48**<br>57.6V<br>55.2V<br>55A<br>47.5 ~ 58.8V<br>93.5%<br>94.5%<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>31.5 ~ 37.5V<br>63 ~ 75V<br>**PROTECTION**<br>**REMOTE ON-OFF CONTROL**<br>By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual<br>**FUNCTION**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>**ENVIRONMENT**<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>UL62368-1, CSA C22.2<br>, TUV<br>EN62368-1, EAC TP TC 004 approved<br>BS EN/<br>No. 62368-1<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>**ISOLATION RESISTANCE**<br>**MTBF**<br>**DIMENSION**<br>**PACKING**<br>**OTHERS**<br>528.8K hrs min.<br>Telcordia SR-332 (Bellcore) ; 44.4K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>325*107*41mm (L*W*H)<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>2.65Kg;4pcs/11.6Kg/0.93CUFT<br>**NOTE**<br>**TEMPERATURE COMPENSATION** -3mV /<br>/ cell / (12V = 6 cells ; 24V = 12 cells ; 48V = 24 cells)<br>℃<br>**AUXILIARY POWER**<br>5V @ 0.3A, tolerance<br>10%, ripple 150mVp-p, 12V @ 0.8A, tolerance<br>10%, ripple 450mVp-p<br>±<br>±<br>**BOOST CHARGE VOLTAGE(Vboost)(default)**<br>**FLOAT CHARGE VOLTAGE(Vfloat)(default)**<br>By built-in potentiometer, SVR<br>**RECOMMENDED BATTERY**<br>**CAPACITY(AMP HOURS) Note.3** 330 ~ 1000Ah<br>18<br>550<br>0 ~<br>Ah<br>**LEAKAGE CURRENT FROM**<br>**BATTERY (Typ.)**<br><1.5mA<br>**CONSTANT CURRENT(CC)(default)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2<br>**Standard**<br>**Standard**<br>BS EN/EN55032 (CISPR32)<br>BS EN/EN55032 (CISPR32)<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-3<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class A<br>Class A<br>-----<br>Adjustment of output voltage is allowable to 75 ~ 125% of nominal output voltage. Please refer to the Function Manual.<br>Adjustment of output voltage is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.<br>**OUTPUT VOLTAGE PROGRAMMABLE(PV)**<br>**OUTPUT CURRENT PROGRAMMABLE(PC)**<br>**DC OK SIGNAL**<br>**AC OK SIGNAL**<br>The isolated TTL signal out. Please refer to the Installation Manual<br>The isolated TTL signal out. Please refer to the Installation Manual<br>℃<br>http://www.meanwell.com)<br>℃<br>℃<br>※<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>:<br>1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.<br>2. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25<br>of ambient temperature.<br>3. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. The charger is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**DBR-3200-24**|**DBR-3200-24**|**DBR-3200-48**|**DBR-3200-48**| |---|---|---|---|---|---| ||**BOOST CHARGE VOLTAGE(Vboost)(default)**|28.8V||57.6V|| ||**FLOAT CHARGE VOLTAGE(Vfloat)(default)**|27.6V||55.2V|| ||**CONSTANT CURRENT(CC)(default)**|110A||55A|| ||**VOLTAGE ADJ. RANGE**|23.5 ~ 30V<br>47.5 ~ 58.8V<br>By built-in potentiometer, SVR|||| ||**RECOMMENDED BATTERY**<br>**CAPACITY(AMP HOURS) Note.3**|330 ~ 1000Ah||18<br>550<br>0 ~<br>Ah|| ||**LEAKAGE CURRENT FROM**<br>**BATTERY (Typ.)**|<1.5mA|||| ||**VOLTAGE RANGE**<br>**Note.4**|90 ~ 264VAC 127 ~ 370VDC|||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||| ||**POWER FACTOR (Typ.)**|0.97/230VAC at full load|||| ||**EFFICIENCY (Typ.)**|93.5%||94.5%|| ||**AC CURRENT (Typ.)**<br>**Note.4**|17A/230VAC|||| ||**INRUSH CURRENT (Typ.)**|COLD START 55A/230VAC|||| ||**LEAKAGE CURRENT**|<1.5mA / 230VAC|||| ||**OVER VOLTAGE**|Protection type : Shut down o/p voltage, re-power on to recover<br>31.5 ~ 37.5V<br>63 ~ 75V|||| ||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down|||| ||**OUTPUT VOLTAGE PROGRAMMABLE(PV)**|Adjustment of output voltage is allowable to 75 ~ 125% of nominal output voltage. Please refer to the Function Manual.|||| ||**OUTPUT CURRENT PROGRAMMABLE(PC)**|Adjustment of output voltage is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.|||| ||**AUXILIARY POWER**|5V @ 0.3A, tolerance<br>10%, ripple 150mVp-p, 12V @ 0.8A, tolerance<br>10%, ripple 450mVp-p<br>±<br>±|||| ||**REMOTE ON-OFF CONTROL**|By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual|||| ||**TEMPERATURE COMPENSATION**|-3mV /<br>/ cell / (12V = 6 cells ; 24V = 12 cells ; 48V = 24 cells)<br>℃|||| ||**DC OK SIGNAL**|The isolated TTL signal out. Please refer to the Installation Manual|||| ||**AC OK SIGNAL**|The isolated TTL signal out. Please refer to the Installation Manual|||| ||**WORKING TEMP.**|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃|||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes|||| ||**SAFETY STANDARDS**|UL62368-1, CSA C22.2<br>, TUV<br>EN62368-1, EAC TP TC 004 approved<br>BS EN/<br>No. 62368-1|||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC|||| ||**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||| |||**Parameter**|**Standard**||**Test Level / Note**| |||Conducted|BS EN/EN55032 (CISPR32)||Class B| |||Radiated|BS EN/EN55032 (CISPR32)||Class A| |||Harmonic Current|BS EN/EN61000-3-2||Class A| |||Voltage Flicker|BS EN/EN61000-3-3||-----| |||BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2|||| |||**Parameter**|**Standard**||**Test Level / Note**| |||ESD|BS EN/EN61000-4-2||Level 3, 8KV air ; Level 2, 4KV contact| |||Radiated|BS EN/EN61000-4-3||Level 3| |||EFT / Burst|BS EN/EN61000-4-4||Level 3| |||Surge|BS EN/EN61000-4-5||2KV/Line-Line 4KV/Line-Earth| |||Conducted|BS EN/EN61000-4-6||Level 3| |||Magnetic Field|BS EN/EN61000-4-8||Level 4| |||Voltage Dips and Interruptions|BS EN/EN61000-4-11||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods| ||**MTBF**|528.8K hrs min.<br>Telcordia SR-332 (Bellcore) ; 44.4K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||| ||**DIMENSION**|325*107*41mm (L*W*H)|||| ||**PACKING**|2.65Kg;4pcs/11.6Kg/0.93CUFT|||| ||℃<br>http://www.meanwell.com)<br>℃<br>℃<br>※<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>:<br>1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.<br>2. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25<br>of ambient temperature.<br>3. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.<br>4. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>5. The charger is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to||||| http://www.meanwell.com) 6. The ambient temperature derating of 3.5 ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:DBR-3200-SPEC 2022-12-05_ ## 3200W Rack Mountable Front End Battery Charger ## **- DBR 3200 series** ## **BLOCK DIAGRAM** **==> picture [496 x 404] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 110KHz<br>PWM fosc : 90KHz<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& ORINGFET -V+V<br>DETECTION<br>CIRCUIT ORING FET<br>CONTROL<br>O.V.P.<br>DETECTION PV/PC<br>CIRCUIT MCU O.T.P.<br>TRANSCEIVERS DA/DB<br>T-Alarm<br>O.T.P. MCU DATA AC-OK<br>ISOLATION DC-OK<br>AUX FAN SDA/SCL<br>POWER AUX. POWER (CANH/CANL)<br>RECTIFIERS<br>& 5V/0.3A Remote ON-OFF<br>FILTER 12V/0.8A<br>DERATING CURVE STATIC CHARACTERISTICS<br>100<br>100<br>90<br>80 80<br>230VAC<br>Input only 70<br>60<br>50 60<br>40 50<br>40<br>20<br>30<br>-30 -25 -10 0 15 30 50 60 70 (HORIZONTAL) 90 100 115 180 264<br>AMBIENT TEMPERATURE (℃) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:DBR-3200-SPEC 2022-12-05_ **- DBR 3200 series** ## 3200W Rack Mountable Front End Battery Charger ## **FUNCTION MANUAL** ## **1.PMBus Communication Interface** - ※ DBR-3200 supports PMBus Rev. 1.1 with maximum 100KHz bus speed, allowing information reading, status monitoring, output trimming, etc. For details, please refer to the Installation Manual. ## **2.Charging Curve** - ※ By factory default, this charger performs the default curve which can be programmed via PMBus. - ※ To disable / enable the charging curve, change to a 2 stage curve, a different curve frequently used for certain types of batteries in the industry, and so on, please refer to the Installation Manual. - ※ To program the parameters of the charging curve, SBP-001, the smart battery charging programmer designed by MEAN WELL, and a personal computer are needed. Please contact MEAN WELL for details. **==> picture [468 x 176] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Default 3 stage charging curve ◎ Embedded 3 stage charging curves<br>3 Stage MODEL Description Vboost Vfloat CC(default)<br>Start Default, programmable 28.8 27.6<br>Vboost<br>Vfloat 24V Pre-defined, gel battery 28 27.2 110A<br>Charge Voltage Pre-defined, flooded battery 28.4 26.8<br>Pre-defined, AGM battery 29 27<br>100% Default, programmable 57.6 55.2<br>Pre-defined, gel battery 56 54.4<br>48V 55A<br>Charge Current Constant Current Constant Voltage Float 10% Pre-defined, flooded battery 56.8 53.6<br>Pre-defined, AGM battery 58 54<br>stage 1 stage 2 stage 3<br>Note:<br>Color of LED Orange Green<br>When using this charger unit, please configured the system with recommended<br>Status Indicator Charger fail if charging time<br>exceed charging timeout battery capacity defined by specification. Should battery capacity in use be<br>Suitable for lead-acid batteries (flooded, Gel and AGM) and much smaller so that user needs to set a low current for charging, under such<br>Li-ion batteries (lithium iron and lithium manganese). condition it might cause higher current ripple.<br>**----- End of picture text -----**<br> - Suitable for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese). ## **3. Remote ON-OFF Control** The charger can be turned ON/OFF individually or along with other units in parallel by using the "Remote ON-OFF" function. **==> picture [334 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> PIN17 Remote ON-OFF switch<br>Between Remote ON-OFF and +5V-AUX Charger Status<br>Switch Short ON<br>Switch Open OFF<br>PIN13 +5V-AUX<br>**----- End of picture text -----**<br> _File Name:DBR-3200-SPEC 2022-12-05_ **-** 3200W Rack Mountable Front End Battery Charger **DBR 3200 series** **4. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)** ※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 75~125% of the nominal voltage by applying EXTERNAL VOLTAGE. **==> picture [414 x 238] intentionally omitted <==** **----- Start of picture text -----**<br> +V<br>LOAD<br>-V<br>PIN27 PV PIN29 -V-signal<br>EXTERNAL VOLTAGE (DC)<br>DBR-3200-48 DBR-3200-24<br>60 30<br>Non-Linear<br>48 24<br>36 18<br>V<br>0 0 0.4 1 4.7 5<br>EXTERNAL VOLTAGE (DC)<br>OUTPUT VOLTAGE(V)<br>**----- End of picture text -----**<br> **==> picture [315 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> 5. Output Current Programming (or, PC / remote current programming / dynamic current trim)<br>**----- End of picture text -----**<br> - ※ The output current can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE. **==> picture [490 x 262] intentionally omitted <==** **----- Start of picture text -----**<br> Iout<br>100<br>+V<br>Non-Linear<br>LOAD<br>-V<br>PIN26 PC PIN29 -V-signal<br>EXTERNAL VOLTAGE (DC)<br>20<br>V<br>0.4 1 4.7 5<br>EXTERNAL VOLTAGE (VDC)<br>6.Temperature Compensation<br>PIN30 RTH+<br>◎ To exploit the temperature compensation function, please<br>attach the temperature sensor, NTC, to the battery or the<br>NTC battery's vicinity.<br>◎ The charger is able to work normally without the NTC.<br>PIN31 RTH-<br>OUTPUT CURRENT (%)<br>**----- End of picture text -----**<br> _File Name:DBR-3200-SPEC 2022-12-05_ **- DBR 3200 series** 3200W Rack Mountable Front End Battery Charger ## **MECHANICAL SPECIFICATION** **==> picture [494 x 722] intentionally omitted <==** **----- Start of picture text -----**<br> Case No.256 Unit:mm<br>5.25 276<br>2-ψ2.8<br>2-M4 L=5<br>276 43.5 10max.<br>41<br>5.8 12.5<br>11max.<br>3.6<br>CN1<br>29.7 Air flow<br>direction<br>SVR<br>6 17<br>325<br>2-M4 L=5<br>2-ψ2.8<br>5.25 276<br>※ LED Status Indicators<br>LED Description<br>Green Float (stage 3)<br>Orange Charging (stage 1 or stage 2)<br>Red The LED will present a constant red light when the abnormal status (OTP, OLP, fan fail and charging timeout) arises.<br>The LED will flash with the red light when the internal temperature reaches 60℃; under this condition, the unit still operates normally<br>Red (Flashing)<br>without entering OTP. (In the meantime, an alarm signal will be sent out through the PMBus interface.)<br>※ Input / Output Connector Pin No. Assignment(CN1) : Positronic PCIM34W13M400A1<br>1 3 5 7 9 11 29 33<br>11 14 17 20 23 26 29<br>1213 1516 1819 2122 2425 2728 3031 Mating Housing Positronic PCIM34W13F400A1<br>2 4 6 8 10 13 31 32 34<br>Pin No. Function Description<br>1,2,3,4,6 -V Negative output terminal.<br>5,7,8,9,10 +V Positive output terminal.<br>11 +12V-AUX Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin 12) .<br>The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by the Remote ON/OFF control.<br>12 GND-AUX Auxiliary voltage output GND.<br>The signal return is isolated from the output terminals (+V & -V).<br>13 +5V-AUX Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX (pin 12) .<br>The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by the Remote ON/OFF control.<br>SCL For PMBus model: Serial Clock used in the PMBus interface. (Note.2)<br>14<br>CANL For CANBus model: Data line used in CANBus interface. (Note.2)<br>SDA For PMBus model: Serial Data used in the PMBus interface. (Note.2)<br>15<br>CANH For CANBus model: Data line used in CANBus interface. (Note.2)<br>High (3.5 ~ 5.5V) : When the internal temperature exceeds the limit of temperature alarm, or when fan fails.<br>16 T-ALARM Low (-0.5 ~ 0.5V) : When the internal temperature is normal, and when fan works normally .<br>The maximum sourcing current is 10mA and only for output(Note.2)<br>17 Remote The unit can turn the output ON/OFF by electrical signal or dry contact between Remote ON/OFF and +5V-AUX . (Note.2)<br>ON-OFF Short (4.5 ~ 5.5V) : Power ON ; Open (-0.5 ~ 0.5V) : Power OFF ; The maximum input voltage is 5.5V.<br>High (3.5 ~ 5.5V) : When the Vout ≦16V/32V ±1V.<br>18 DC-OK Low (-0.5 ~ 0.5V) : When Vout ≧16V/32V ±1V. The maximum sourcing current is 10mA and only for output. (Note.2)<br>DC OK is associated with battery low protection.<br>High (3.5 ~ 5.5V) : When the input voltage is ≧87Vrms .<br>19 AC-OK Low (-0.5 ~ 0.5V) : When the input voltage is ≦75Vrms.<br>The maximum sourcing current is 10mA and only for output. (Note.2)<br>20 D0 Interface lines for charging curve selection. (Note.1)<br>21,22,23 A2,A1,A0 PMBus interface address lines. (Note.1)<br>24,25 DB,DA Differential digital signal for parallel control. (Note.1)<br>26 PC Connection for output current programming. (Note.1)<br>27 PV Connection for output voltage programming. (Note.1)<br>28 +V(signal) Positive output voltage signal.<br>It cannot be connected directly to the load.<br>29 -V(signal) Negative output voltage signal.<br>It is for certain function reference; it cannot be connected directly to the load.<br>30 RTH+<br>Temperature sense associated with the temperature compensation function.<br>31 RTH-<br>32 FG AC Ground connection.<br>33 AC/L AC Line connection.<br>34 AC/N AC Neutral connection.<br>18.6<br> Indicator<br>LED Status<br>53.5<br>107 62.4<br>47.3<br>16.8 22.8<br>16.8 22.8<br>127 137<br>15 4<br>**----- End of picture text -----**<br> Note1: Non-isolated signal, referenced to [-V(signal)]. Note2: Isolated signal, referenced to GND-AUX. _File Name:DBR-3200-SPEC 2022-12-05_
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →