Image not available
Illustrative purposes only
D7PAD
RELAY SOCKET, 15A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON CUTLER HAMMER
- Product type: Relay Sockets
- Socket Mounting:DIN Rail; Socket Terminals:Screw; No. of Pins:-; Current Rating:15A; Voltage Rating:120V; Product Range:D7 Series; Accessory Type:Relay Socket; For Use With:Eaton D7 40T8629
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 23.57 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Control Relays and Timers
|**D1 Series General Purpose Relay**|**D1 Series General Purpose Relay**|**3.1**|**Relay Products**<br>Control Relays and Timers Comparison . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-2**|**3**|
|---|---|---|---|---|---|
|PY.<br>~~<br>«a2||**3.2**|**_XR_ Series Terminal Block Relays**<br>_Standard, OptoCoupler and High Current_||**3**<br>**3**|
||||Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-3**||
|||**3.3**|**EASY Intelligent Relays**||**3**|
||||_Relays, Modules, Power Supplies, Accessories and Software_||**3**|
|‘ul|||Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-19**|**3**|
|||**3.4**|**General Purpose Plug-In Relays**|||
||||_General Purpose Relays_||**3**|
|**D96 Series Solid-State Relay**|||Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-42**|**3**|
|Pa|>|**3.5**|**General Purpose Relays—Type AA**<br>_9575H Series 3000 Relay_||**3**|
||||9575H Series 3000—Type AA, AC and DC. . . . . . . . . . . . . . . . . . . . . .|**V7-T3-116**|**3**|
|=|<p|**3.6**|**Solid-State Relays**<br>_D93, D96 and D99 Series_<br>Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-120**|**3**<br>**3**|
|**Universal TR Series Timing Relay**||**3.7**|**Machine Tool Relays**<br>_Freedom Multipole, Industrial Control, and_||**3**|
||||_Multipole with Convertible Contacts_||**3**|
|ce|||Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-139**|**3**|
|||**3.8**|**Timing Relays**|||
||||_Universal TR, TR and TMR Series_||**3**|
||||Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-165**|**3**|
|||**3.9**|**Alternating Relays**<br>_D85 Series_||**3**|
||||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-186**|**3**|
|||**3.10**|**Safety Relays**<br>Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-19/**|**3**|
||||Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-190**|**3**|
||||Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-191**<br>**V7-T3-194**|**3**|
Learn Online
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-1**
Control Relays and Timers
3.1
Relay Product Overview
**3 Relay Products 3 3**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|**_XR_**Series Terminal Block Relays . . . . . . . . . . . . . .|**V7-T3-3**|
|EASY Intelligent Relays . . . . . . . . . . . . . . . . . . . . .<br>General Purpose Plug-In Relays . . . . . . . . . . . . . . .|**V7-T3-19**<br>**V7-T3-42**|
|General Purpose Relays—Type AA . . . . . . . . . . . .<br>Solid-State Relays . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-116**<br>**V7-T3-120**|
|Machine Tool Relays . . . . . . . . . . . . . . . . . . . . . . .<br>Timing Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-139**<br>**V7-T3-165**|
|Alternating Relays . . . . . . . . . . . . . . . . . . . . . . . . .<br>Safety Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-186**<br>**V7-T3-191**|
## **Control Relays and Timers Comparison**
## **Selection Guide by Catalog Number Prefix**
|**Relays**<br>9575H3|**Type**<br>General purpose|**Mounting**<br>Panel mount|**Contacts**<br>Fixed|**Maximum**<br>**Amperage**<br>**(AC)**<br>40A|—<br>Ww|**UL**<br>X|**CSA**<br>X|**CE**<br>X|**Page**<br>**Number**<br>**V7-T3-117**|
|---|---|---|---|---|---|---|---|---|---|
|AR/ARD|Machine tool|Panel mount|Convertible|10A|—|X|X|—|**V7-T3-152**|
|BF/BFD|Machine tool|Panel mount|Fixed|10A|X|—|X|—|**V7-T3-146**|
|D2PF|Full featured plug-in|DIN rail/panel mount|Fixed|10A|X|—|X|X|**V7-T3-53**|
|D2PR|Standard plug-in|DIN rail/panel mount/flange|Fixed|10A|X|—|X|X|**V7-T3-53**|
|D3PF|Full featured plug-in|DIN rail/panel mount|Fixed|16A|X|—|X|X|**V7-T3-63**|
|D3PR<br>D4PR|Standard plug-in<br>Standard plug-in|DIN rail/panel mount<br>DIN rail/panel mount|Fixed<br>Fixed|16A<br>10A|X<br>X|—<br>—|X<br>X|X<br>X|**V7-T3-63**<br>**V7-T3-72**|
|D5PF|Full featured plug-in|DIN rail/panel mount|Fixed|16A|X|—|X|X|**V7-T3-77**|
|D5PR|Standard plug-in|DIN rail/panel mount/PC board|Fixed|16A|X|—|X|X|**V7-T3-77**|
|D7PF|Full featured plug-in|DIN rail/panel mount|Fixed|20A|X|—|X|X|**V7-T3-87**|
|D7PR<br>D8PR|Standard plug-in<br>Standard plug-in|DIN rail/panel mount/flange<br>DIN rail/panel mount/flange|Fixed<br>Fixed|20A<br>30A|X<br>X|—<br>—|X<br>X|X<br>X|**V7-T3-88**<br>**V7-T3-101**|
|D9PR<br>D15|Standard plug-in<br>Machine tool|Panel mounting<br>DIN rail/panel mount|Fixed<br>Fixed|25A<br>10A|X<br>—|—<br>X|X<br>X|—<br>X|**V7-T3-107**<br>**V7-T3-141**|
|D26|Machine tool|Panel or channel mount|Convertible|10A|—|X|X|—|**V7-T3-157**|
|D85|Alternating relays|DIN rail/panel mount|Fixed|10A|X|X|—|X|**V7-T3-187**|
|D1PF|Full featured plug-in|DIN rail/panel mount|Fixed|20A|X|—|X|X|**V7-T3-47**|
|D1PR<br>EASY|Standard plug-in<br>Intelligent relay|DIN rail/panel mount<br>DIN rail|Fixed<br>Fixed|20A<br>8A|X<br>X|—<br>—|X<br>X|X<br>X|**V7-T3-47**<br>**V7-T3-21**|
|TMR5|Timing relay (non-programmable)|DIN rail/panel mount|Fixed|10A|X|X|—|X|**V7-T3-178**|
|TMR6|Timing relay (non-programmable)|DIN rail/panel mount|Fixed|10A|X|X|—|X|**V7-T3-182**|
|TR|Timing relay (programmable)|DIN rail/panel mount|Fixed|10A|—|X|X|—|**V7-T3-175**|
|Universal TR|Timing relay (programmable)|DIN rail|Fixed|8A|—|X|X|X|**V7-T3-171**|
|XR|Terminal block relay|DIN rail|Fixed|6A, 10A|X|—|—|X|**V7-T3-5**|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-2**
Control Relays and Timers
3.2
Relay Product Overview
_**XR**_ **Series Terminal Block Relays**
## **Contents**
|**_Description_**<br>**_XR_**Series Terminal Block Relays<br>Standard Terminal Block Relays . . . . . . . . . . . .<br>OptoCoupler Terminal Block Relays . . . . . . . . .<br>High Current Terminal Block Relays . . . . . . . . .<br>**_XR_**Series Accessories . . . . . . . . . . . . . . . . . . .|**_Page_**<br>**V7-T3-4**<br>**V7-T3-12**<br>**V7-T3-15**<br>**V7-T3-18**|**3**<br>**3**<br>**3**|
|---|---|---|
## **Catalog Number Selection**
_**XR**_ **Series—Overview**
**==> picture [345 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
XR U 1 D 12 G<br>Description Gold-Flashed Contacts<br>XR = XR terminal block relay Blank = No<br>G = Yes<br>Connection Type<br>U = Screw Poles Voltage<br>P = Spring 1 = 1PDT 12 = 12 Vdc<br>R = Replacement relay 2 = 2PDT Type 24 = 24 Vdc<br>D = Standard relay 24U = 24 Vac/Vdc<br>S = Octocoupler (solid-state) 120U = 120 Vac/110 Vdc<br>== H = High current 230U = 230 Vac/220 Vdc<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-3**
3.2
## Control Relays and Timers
XR Series Terminal Block Relays
**3**
**==> picture [88 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Standard Terminal Block Relay<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Standard Terminal Block Relays||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-5**|
|Technical Data and Specifications . . . . . . . . . .|**V7-T3-6**|
|Electrical Schematics . . . . . . . . . . . . . . . . . . . .|**V7-T3-11**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-11**|
|OptoCoupler Terminal Block Relays . . . . . . . . . . .|**V7-T3-12**|
|High Current Terminal Block Relays . . . . . . . . . . .|**V7-T3-15**|
|**_XR_**Series Accessories . . . . . . . . . . . . . . . . . . . . .|**V7-T3-18**|
## **Standard Terminal Block Relays**
## **Product Description**
The _**XR**_ Series Terminal Block Relays are ideal for applications that require a high switching capacity and long electrical service life. The relays are plug-in interfaces that connect to basic terminal blocks. The _**XR**_ Series uses screw or spring-cage technology, as well as offers quick system wiring, superior safety features, clear labeling and a high level of modularity.
## **Application Description**
Used in automation systems, electromechanical relays guarantee a safe connection between process I/O and electronic controls. The following functions are covered by relay coupling elements:
- Electrical isolation between the input and output circuits
- Independence of the type of switching current (AC and DC)
- High short-term overload resistance in the event of short circuits or voltage peaks
## **Features**
- Gold-plated contacts available
- Pluggable relay allows for field replacement
- Equipped with a robust, miniature relay:
- Functional plug-in bridges
- Choice of screw connections or spring-cage connection
- IP67 protection
- Environmentally friendly, cadmium-free contact material
- LED status indication
- DIN rail mount
- Easy, cost-effective installation and replacement using the engagement lever
- Only 6.2 mm wide for single-pole versions, 14 mm wide for doublepole
- All common input voltages between 12 Vdc to 120 Vac ● cULus listed
## **Standards and Certifications**
- CE
- Low switching losses
- Ease of operation
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-4**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
## **Product Selection**
## **XRU1D 24U**
## **Standard Terminal Block Relays**
|**Gold-Plated**|**Rated**|**Supply**|**Standard**|**Catalog**|
|---|---|---|---|---|
|**Contacts**|**Current**|**Voltage**|**Pack**|**Number**|
|**1PDT Screw Connection**|**1PDT Screw Connection**||||
|No|6A|12 Vdc|10|**XRU1D12**|
|No|6A|120 Vac/110 Vdc|10|**XRU1D120U**|
|Yes|6A|120 Vac/110 Vdc|10|**XRU1D120UG**|
|No|6A|24 Vdc|10|**XRU1D24**|
|No|6A|24 Vac/Vdc|10|**XRU1D24U**|
|Yes|6A|24 Vac/Vdc|10|**XRU1D24UG**|
|No|6A|230 Vac/220 Vdc|10|**XRU1D230U**|
|**1PDT Spring Cage Connection**|**1PDT Spring Cage Connection**||||
|No|6A|12 Vdc|10|**XRP1D12**|
|No|6A|120 Vac/110 Vdc|10|**XRP1D120U**|
|No|6A|24 Vdc|10|**XRP1D24**|
|No|6A|24 Vac/Vdc|10|**XRP1D24U**|
|No|6A|230 Vac/220 Vdc|10|**XRP1D230U**|
|**DPDT Screw Connection**|**DPDT Screw Connection**||||
|No|6A|12 Vdc|10|**XRU2D12**|
|No|6A|120 Vac/110 Vdc|10|**XRU2D120U**|
|No|6A|24 Vdc|10|**XRU2D24**|
|No|6A|24 Vac/Vdc|10|**XRU2D24U**|
|No|6A|230 Vac/220 Vdc|10|**XRU2D230U**|
**3**
|**Standard Replacement Relays**|**Standard Replacement Relays**|**Standard Replacement Relays**|||
|---|---|---|---|---|
|**Gold-Plated**|**Rated**|**Supply**|**Standard**|**Catalog**|
|**Contacts**|**Current**|**Voltage**|**Pack**|**Number**|
|**1PDT**|||||
|No|6A|12 Vdc|10|**XRR1D12**|
|No|6A|120 Vac/110 Vdc|10|**XRR1D120U**|
|Yes|6A|120 Vac/110 Vdc|10|**XRR1D120UG**|
|No|6A|24 Vdc|10|**XRR1D24**|
|Yes|6A|24 Vdc|10|**XRR1D24G**|
|**DPDT**|||||
|No|6A|12 Vdc|10|**XRR2D12**|
|No|6A|120 Vac/110 Vdc|10|**XRR2D120U**|
|No|6A|24 Vdc|10|**XRR2D24**|
|No|6A|230 Vac/220 Vdc|10|**XRR2D230U**|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-5**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
## **Technical Data and Specifications**
## **Standard 1PDT Screw Connection Terminal Block Relays**
**3**
|**Standard 1PDT Screw**|**Connection Terminal Block**|**Relays**|||
|---|---|---|---|---|
|**Catalog Number**|**XRU1D12**|**XRU1D24**|**XRU1D24U**|**XRU1D120U**|
|**Replacement Relay**<br>Input voltage|**XRR1D12**<br>12 Vdc|**XRR1D24**<br>24 Vdc|**XRR1D24**<br>24 Vac/Vdc|**XRR1D120U**<br>120 Vac/110 Vdc|
|**Connection Data**|||||
|Rigid solid AWG (mm2)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|
|Flexible stranded AWG (mm2)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|
|**Input Data for 1PDT Screw**<br>Input voltage|**Connection Versions**<br>12 Vdc|24 Vdc|24 Vac/Vdc|120 Vac/110 Vdc|
|Permissible range|See**Page V7-T3-10**|See**Page V7-T3-10**|See**Page V7-T3-10**|See**Page V7-T3-10**|
|Typical input current|15.3 mA|9 mA|11 mA (24 Vac)/8.5 mA (24 Vdc)|3.5 mA (120 Vac)/3 mA (110 Vdc)|
|Typical response time|5 ms|5 ms|6 ms|6 ms|
|Typical release time|8 ms|8 ms|15 ms|15 ms|
|Input protection|Polarity protection diode,|Polarity protection diode,|Bridge rectifier|Bridge rectifier|
||free-wheeling diode|free-wheeling diode|||
|**Output Data**|||||
|Contact type<br>Contact material|1PDT<br>AgSnO|1PDT<br>AgSnO|1PDT<br>AgSnO|1PDT<br>AgSnO|
|Max. switching voltage|250 Vac/Vdc1|250 Vac/Vdc1|250 Vac/Vdc1|250 Vac/Vdc1|
|Min. switching voltage|12 Vac/Vdc|12 Vac/Vdc|12 Vac/Vdc|12 Vac/Vdc|
|Limiting continuous current|6A|6A|6A|6A|
|Min. switching current|10 mA|10 mA|10 mA|10 mA|
|Min. switching power|120 mW|120 mW|120 mW|120 mW|
|**Miscellaneous Data**<br>Ambient temp range|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|
|Rated operating mode|100% operating factor|100% operating factor|100% operating factor|100% operating factor|
|Inflammability class|V0, in accordance with UL 94|V0, in accordance with UL 94|V0, in accordance with UL 94|V0, in accordance with UL 94|
|Mechanical service life|2 x 107cycles|2 x 107cycles|2 x 107cycles|2 x 107cycles|
## _**Note**_
> 1 The separating plate, XRAPLCESK, should be installed for voltages greater than 250V (L1, L2, L3) between identical terminal points of adjacent modules. Potential bridging is then possible with the XRAFBST bridge system.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-6**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
## **Standard 1PDT Screw Connection Terminal Block Relays with Gold Contacts**
|**Catalog Number**|**XRU1D24UG**|**XRU1D120UG**|
|---|---|---|
|**Replacement Relay**|**XRR1D24G**|**XRR1D120UG**|
|Input voltage|24 Vac/Vdc|120 Vac/110 Vdc|
|**Connection Data**|||
|Rigid solid AWG (mm2)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|
|Flexible stranded AWG (mm2)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|
|**Input Data for 1PDT Screw Connection Versions with Gold Contacts**|||
|Input voltage|24 Vac/Vdc|120 Vac/110 Vdc|
|Permissible range|See**Page V7-T3-10**|See**Page V7-T3-10**|
|Typical input current|11 mA (24 Vac)/8.5 mA (24 Vdc)|3.5 mA (120 Vac)/3 mA (110 Vdc)|
|Typical response time|6 ms|6 ms|
|Typical release time|15 ms|15 ms|
|Input protection|Bridge rectifier|Bridge rectifier|
|**Output Data**|||
|Contact type|1PDT|1PDT|
|Contact material|AgSnO, gold plated1|AgSnO, gold plated1|
|Max. switching voltage|30 Vac/36 Vdc (250 Vac/Vdc)2|30 Vac/36 Vdc (250 Vac/Vdc)2|
|Min. switching voltage|100 mV (12 Vac/Vdc)2|100 mV (12 Vac/Vdc)2|
|Limiting continuous current|50 mA (6A)2|50 mA (6A)2|
|Min. switching current|1 mA (10 mA)2|1 mA (10 mA)2|
|Min. switching power|100 mW (120 mW)2|100 mW (120 mW)2|
|**Miscellaneous Data**|||
|Ambient temp range|–4° to 140°F (–20° to 60°C)|–40° to 131°F (–20° to 55°C)|
|Rated operating mode|100% operating factor|100% operating factor|
|Inflammability class|V0, in accordance with UL 94|V0, in accordance with UL 94|
|Mechanical service life|2 x 107cycles|2 x 107cycles|
**3**
## _**Notes**_
- 1 The separating plate, XRAPLCESK, should be installed for voltages greater than 250V (L1, L2, L3) between identical terminal points of adjacent modules. Potential bridging is then possible with the XRAFBST bridge system.
- 2 If the maximum values are exceeded, the gold layer is destroyed and the values in parentheses apply.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-7**
3.2
**3**
## Control Relays and Timers
## XR Series Terminal Block Relays
## **Standard 1PDT Spring Cage Terminal Block Relays**
|**Catalog Number**|**XRP1D12**|**XRP1D24**|**XRP1D24U**|**XRP1D120U**|
|---|---|---|---|---|
|**Replacement Relay**|**XRR1D12**|**XRR1D24**|**XRR1D24**|**XRR1D120U**|
|Input voltage|12 Vdc|24 Vdc|24 Vac/Vdc|120 Vac/110 Vdc|
|**Connection Data**|||||
|Rigid solid AWG (mm2)<br>Flexible stranded AWG (mm2)|26–14 (0.14–2.5)<br>26–14 (0.14–2.5)|26–14 (0.14–2.5)<br>26–14 (0.14–2.5)|26–14 (0.14–2.5)<br>26–14 (0.14–2.5)|26–14 (0.14–2.5)<br>26–14 (0.14–2.5)|
|**Input Data for 1PDT Spring Cage Versions**<br>Input voltage<br>12 Vdc||24 Vdc|24 Vac/Vdc|120 Vac/110 Vdc|
|Permissible range|See**Page V7-T3-10**|See**Page V7-T3-10**|See**Page V7-T3-10**|See**Page V7-T3-10**|
|Typical input current|15.3 mA|9 mA|11 mA (24 Vac)/8.5 mA (24 Vdc)|3.5 mA (120 Vac)/3 mA (110 Vdc)|
|Typical response time|5 ms|5 ms|6 ms|6 ms|
|Typical release time<br>Input protection|8 ms<br>Polarity protection diode,|8 ms<br>Polarity protection diode,|15 ms<br>Bridge rectifier|15 ms<br>Bridge rectifier|
|**Output Data**|free-wheeling diode|free-wheeling diode|||
|Contact type<br>Contact material|1PDT<br>AgSnO|1PDT<br>AgSnO|1PDT<br>AgSnO|1PDT<br>AgSnO|
|Max. switching voltage|250 Vac/Vdc1|250 Vac/Vdc1|250 Vac/Vdc1|250 Vac/Vdc1|
|Min. switching voltage|12 Vac/Vdc|12 Vac/Vdc|12 Vac/Vdc|12 Vac/Vdc|
|Limiting continuous current|6A|6A|6A|6A|
|Min. switching current<br>Min. switching power|10 mA<br>120 mW|10 mA<br>120 mW|10 mA<br>120 mW|10 mA<br>120 mW|
|**Miscellaneous Data**|||||
|Ambient temp range|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|–4° to 131°F (–20° to 55°C)|
|Rated operating mode|100% operating factor|100% operating factor|100% operating factor|100% operating factor|
|Inflammability class|V0, in accordance with UL 94|V0, in accordance with UL 94|V0, in accordance with UL 94|V0, in accordance with UL 94|
|Mechanical service life|2 x 107cycles|2 x 107cycles|2 x 107cycles|2 x 107cycles|
## _**Note**_
> 1 The separating plate, XRAPLCESK, should be installed for voltages greater than 250V (L1, L2, L3) between identical terminal points of adjacent modules. Potential bridging is then possible with the XRAFBST bridge system.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-8**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
**3**
## **Standard DPDT Screw Connection Terminal Block Relays**
|**Catalog Number**|**XRU2D12**|**XRU2D24**|**XRU2D24U**|**XRU2D120U**|
|---|---|---|---|---|
|**Replacement Relay**|**XRR2D12**|**XRR2D24**|**XRR2D24**|**XRR2D120U**|
|Input voltage|12 Vdc|24 Vdc|24 Vac/Vdc|120 Vac/110 Vdc|
|**Connection Data**|||||
|Rigid solid AWG (mm2)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|
|Flexible stranded AWG (mm2)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|
|**Input Data for 1PDT Spring Cage Versions**<br>Input voltage<br>12 Vdc||24 Vdc|24 Vac/Vdc|120 Vac/110 Vdc|
|Permissible range|See**Page V7-T3-10**|See**Page V7-T3-10**|See**Page V7-T3-10**|See**Page V7-T3-10**|
|Typical input current|33 mA|18 mA|17.5 mA|4.5 mA (120 Vac)/4.2 mA (110 Vdc)|
|Typical response time|8 ms|8 ms|8 ms|7 ms|
|Typical release time<br>Input protection|10 ms<br>Polarity protection diode,|10 ms<br>Polarity protection diode,|10 ms<br>Bridge rectifier|10 ms<br>Bridge rectifier|
||free-wheeling diode|free-wheeling diode|||
|**Output Data**|||||
|Contact type<br>Contact material|2PDT<br>AgNi|Single contact, 2PDT<br>AgNi|Single contact, 2PDT<br>AgNi|Single contact, 2PDT<br>AgNi|
|Max. switching voltage|250 Vac/Vdc1|250 Vac/Vdc1|250 Vac/Vdc1|250 Vac/Vdc1|
|Min. switching voltage|5V|5V|5V|5V|
|Limiting continuous current|6A|6A|6A|6A|
|Max. inrush current<br>Min. switching current|15A (300 ms)<br>10 mA|15A (300 ms)<br>10 mA|15A (300 ms)<br>10 mA|15A (300 ms)<br>10 mA|
|Min. switching power|50 mW|50 mW|50 mW|50 mW|
|**General Data**|||||
|Ambient temp range|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|
|Rated operating mode|100% operating factor|100% operating factor|100% operating factor|100% operating factor|
|Inflammability class|V0, in accordance with UL 94|V0, in accordance with UL 94|V0, in accordance with UL 94|V0, in accordance with UL 94|
|Mechanical service life|3 x 107cycles|3 x 107cycles|3 x 107cycles|3 x 107cycles|
## _**Note**_
> 1 The separating plate, XRAPLCESK, should be installed for voltages greater than 250V (L1, L2, L3) between identical terminal points of adjacent modules. Potential bridging is then possible with the XRAFBST bridge system.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-9**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
## _**Permissible Range Diagrams**_
## 1PDT Relay Modules
## **Operating Range Voltage for 12 Vdc**
## DPDT Relay Modules **Operating Range Voltage for 12 Vdc**
**==> picture [445 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.4 1.4<br>3 1.3 A 1.3 A<br>3 1.2 1.2<br>U 1.1 U 1.1<br>3 UN 1.0 UN = 12 Vdc UN 1.0 UN = 12 Vdc<br>0.9 0.9<br>3 0.8 B 0.8 B<br>0.7 0.7<br>3 20 25 30 35 T 40 N [°C] 45 50 55 60 65 20 25 30 35 T 40 N [°C] 45 50 55 60 65<br>**----- End of picture text -----**<br>
## **Operating Range Voltage for 120 Vac/110 Vdc**
**==> picture [140 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.4<br>A<br>1.3<br>1.2<br>U 1.1<br>UN 1.0<br>UN = 110 Vdc/120 Vac<br>0.9<br>0.8<br>B<br>0.7<br>20 25 30 35 40 45 50 55 60 65<br>TN [°C]<br>**----- End of picture text -----**<br>
## **Operating Range Voltage for 24 Vdc**
**==> picture [140 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.4<br>A<br>1.3<br>1.2<br>U 1.1<br>UN 1.0 UN = 24 Vdc<br>0.9<br>0.8<br>B<br>0.7<br>20 25 30 35 40 45 50 55 60 65<br>TN [°C]<br>**----- End of picture text -----**<br>
## **Operating Range Voltage for 120 Vac/110 Vdc**
**==> picture [140 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.4<br>A<br>1.3<br>1.2<br>UN = 120 Vac<br>U 1.1<br>UN 1.0 U N = 110 Vdc<br>0.9<br>B<br>0.8<br>0.7<br>20 25 30 35 40 45 50 55 60 65<br>TN [°C]<br>Operating Range Voltage for 24 Vdc<br>1.4<br>A<br>1.3<br>1.2<br>U 1.1<br>UN 1.0 UN = 24 Vdc<br>0.9<br>0.8<br>B<br>0.7<br>20 25 30 35 40 45 50 55 60 65<br>TN [°C]<br>**----- End of picture text -----**<br>
## **Operating Range Voltage for 24 Vdc**
## **Operating Range Voltage for 24 Vac/Vdc**
## **Operating Range Voltage for 24 Vac/Vdc**
**==> picture [401 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.4 1.4<br>A A<br>1.3 1.3<br>1.2 1.2<br>U 1.1 U 1.1<br>UN 1.0 UN = 24 Vdc/24 Vac UN 1.0 UN = 24 Vdc/24 Vac<br>0.9 0.9<br>B<br>0.8 0.8<br>B<br>0.7 0.7<br>20 25 30 35 40 45 50 55 60 65 20 25 30 35 40 45 50 55 60 65<br>TN [°C] TN [°C]<br>**----- End of picture text -----**<br>
## _**Notes**_
**General Conditions** — Direct alignment in the block, all devices 100% operating factor, horizontal or vertical mounting.
**Curve A** — Maximum permissible continuous operating voltage Umax with limiting continuous current on the contact side (see respective technical data). **Curve B** — Minimum permissible relay operate voltage Uop after pre-excitation[1] ) (see respective technical data).
> 1 Pre-excitation: Relay has been operated in a thermally steady state at the ambient temperature TU with nominal voltage UN and limiting continuous current on the contact side (see respective technical data) (warm coil). After being switched off for a short time, the relay must reliably pick up again at Uop.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-10**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
## **Electrical Schematics**
## **1PDT Terminal Block Relays**
**==> picture [164 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
A2 11<br>A1 14<br>12<br>**----- End of picture text -----**<br>
## **DPDT Terminal Block Relays**
**==> picture [178 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
21<br>24<br>22<br>11<br>14<br>12<br>**----- End of picture text -----**<br>
**==> picture [9 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
A2<br>A1<br>**----- End of picture text -----**<br>
**3**
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Standard 1PDT Terminal Block Relays**
**==> picture [197 x 238] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.70 (94.0)<br>3.15 (80.0)<br>0.24 (6.2)<br>**----- End of picture text -----**<br>
## **Standard DPDT Terminal Block Relays**
**==> picture [197 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.70 (94.0)<br>3.15 (80.0)<br>0.55 (14.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-11**
3.2
## Control Relays and Timers
XR Series Terminal Block Relays
**3 OptoCoupler Terminal Block Relay 3 3**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Standard Terminal Block Relays . . . . . . . . . . . . . .|**V7-T3-4**|
|OptoCoupler Terminal Block Relays||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-13**|
|Technical Data and Specifications . . . . . . . . . . .|**V7-T3-13**|
|Electrical Schematic . . . . . . . . . . . . . . . . . . . . .|**V7-T3-14**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-14**|
|High Current Terminal Block Relays . . . . . . . . . . .|**V7-T3-15**|
|**_XR_**Series Accessories . . . . . . . . . . . . . . . . . . . . .|**V7-T3-18**|
## **OptoCoupler Terminal Block Relays**
## **Product Description**
The _**XR**_ Series OptoCoupler Terminal Block Relays can be used in all applications and consist of a pluggable miniature OptoCoupler and a basic terminal block. The _**XR**_ Series uses screw or springcage technology, as well as offers quick system wiring, superior safety features, clear labeling and a high level of modularity.
## **Application Description**
The _**XR**_ Series OptoCoupler relays can be used as an input or output interface. They provide the typical reliability of OptoCouplers and are especially suited for high operating frequencies.
## **Features**
- Pluggable relay allows for field replacement
- Functional plug-in bridges
- LED status indication
- DIN rail mount
- Only 6.2 mm wide
- Switching capacity up to 24 Vdc/3A
- IP67-protected optical electronics
- Wear-resistant and bouncefree switching
## **Standards and Certifications**
- cULus listed
- CE
- Insensitive to shock and vibration
- Integrated protection circuit
- Zero voltage switch at AC output
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-12**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
## **Product Selection**
## **XRU1S24**
## **OptoCoupler Terminal Block Relays**
||||**Catalog**|
|---|---|---|---|
|**Rated Current**|**Supply Voltage**|**Standard Pack**|**Number**|
|2A|120 Vac/110 Vdc|10|**XRU1S120U**|
|2A|24 Vdc|10|**XRU1S24**|
**3**
## **OptoCoupler Replacement Relays**
||||**Catalog**|
|---|---|---|---|
|**Rated Current**|**Supply Voltage**|**Standard Pack**|**Number**|
|2A|24 Vdc|18|**XRR1S24**|
|2A|120 Vac/110 Vdc|10|**XRR1S120U**|
## **Technical Data and Specifications**
## **Pluggable Power OptoCoupler (Solid-State) Terminal Block Relays**
|**Catalog Number**|**XRU1S24**|**XRU1S120U**|
|---|---|---|
|**Replacement Relay**|**XRR1S24**|**XRR1S120U**|
|Input voltage|24 Vdc|120 Vac/110 Vdc|
|**Connection Data**|||
|Rigid solid AWG (mm2)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|
|Flexible stranded AWG (mm2)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|
|**Input Data**|||
|Input voltage|24 Vdc|120 Vac/110 Vdc|
|Permissible range|0.8–1.2|0.8 –1.1|
|Typical input current|9 mA|4 mA|
|Switching level 1 signal (“H”)|><br>~~0~~.8|><br>~~0~~.8|
|Switching level 0 signal (“L”)|<<br>~~0~~.4|<<br>~~0~~.25|
|Typical switch-on time|20 μS|6 ms|
|Typical turn-off time|500 μS|10 ms|
|Input protection|Polarity protection diode,|Bridge rectifier|
||free-wheeling diode||
|**Output Data**|||
|Max. switching voltage|33 Vdc|33 Vdc|
|Min. switching voltage|3 Vdc|3 Vdc|
|Limiting continuous current|3A (See derating curve)|3A (See derating curve)|
|Max. inrush current|15A (10 ms)|15A (10 ms)|
|Output circuit|2-conductor floating|2-conductor floating|
|Output protection|Polarity protection, surge protection|Polarity protection, surge protection|
|Voltage drop at maximum|<<br> 200 mV|<<br> 200 mV|
|limiting continuous current|||
|**General Data**|||
|Ambient temp range|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|
|Rated operating mode|100% operating factor|100% operating factor|
|Inflammability class|V0, in accordance with UL 94|V0, in accordance with UL 94|
|Mechanical service life|2 x 107cycles|2 x 107cycles|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-13**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
**3**
## _**Derating Curve**_
## **OptoCoupler**
**==> picture [170 x 285] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>2<br>1<br>0<br>0 10 20 30 40 50 60<br>Ambient Temperature (°C)<br>Electrical Schematic<br>Pluggable Power OptoCoupler (Solid-State)<br>Terminal Block Relays<br>A2 13+<br>A1 14<br>Load Current (A)<br>**----- End of picture text -----**<br>
**Pluggable Power OptoCoupler (Solid-State) Terminal Block Relays**
## **Dimensions**
Approximate Dimensions in Inches (mm)
**Pluggable Power OptoCoupler (Solid-State) Terminal Block Relays**
**==> picture [198 x 238] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.70 (94.0)<br>3.15 (80.0)<br>0.24 (6.2)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-14**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
## **High Current Terminal Block Relay**
## **Contents**
|**Contents**||**3**|
|---|---|---|
|**_Description_**|**_Page_**||
|Standard Terminal Block Relays . . . . . . . . . . . . . . .|**V7-T3-4**|**3**|
|OptoCoupler Terminal Block Relays . . . . . . . . . . . .<br>High Current Terminal Block Relays|**V7-T3-12**|**3**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .<br>Technical Data and Specifications . . . . . . . . . .|**V7-T3-16**<br>**V7-T3-16**|**3**|
|Electrical Schematic . . . . . . . . . . . . . . . . . . . . .<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-17**<br>**V7-T3-17**|**3**|
|**_XR_**Series Accessories . . . . . . . . . . . . . . . . . . . . .|**V7-T3-18**|**3**|
## **High Current Terminal Block Relays**
## **Product Description**
The _**XR**_ Series Relays include products designed to meet high continuous current and/ or long electrical service life applications. The _**XR**_ Series Relays are plug-in interfaces that connect to basic terminal blocks that use screw connection technology. Overall width is 14 mm.
## **Application Description**
These relays are best suited for applications that require higher continuous load currents than miniature relays can carry and switch. They can withstand inrush currents or brief overloads without damage, and allow for continuous load currents of up to 10A. The _**XR**_ Series Relay boasts an average service life of the contacts that is two or three times the normal life of a less powerful relay, resulting in service cost savings.
## **Features**
- 14 mm wide
- Pluggable relay allows for field replacement
- Convenient plug-in bridge system
- LED status indication
- DIN Rail Mount
- IP67-protected optical electronics
- Wear-resistant and bouncefree switching
- Insensitive to shock and vibration
- Integrated protection circuit
## **Standards and Certifications**
- cULus listed
- CE
- Zero voltage switch at AC output
- Environmentally friendly, cadmium-free contact material
- Electrical isolation between input and output
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-15**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
## **Product Selection**
## **High Current Terminal Block Relays**
**XRU1H24 3 Catalog Rated Current Supply Voltage Standard Pack Number 3** 10A 12 Vdc 10 **XRU1H12** 10A 120 Vac/110 Vdc 10 **XRU1H120U 3** 10A 24 Vdc 10 **XRU1H24** ~~TP~~ 10A 24 Vac/Vdc 10 **XRU1H24U**
## **High Current Replacement Relays**
|**Rated Current**|**Supply Voltage**|**Standard Pack**|**Catalog**<br>**Number**|
|---|---|---|---|
|10A|24 Vdc|10|**XRR1H24**|
|10A|24 Vac/Vdc|10|**XRR1H24U**|
|10A<br>10A|12 Vdc<br>120 Vac/110 Vdc|10<br>10|**XRR1H12**<br>**XRR1H120U**|
## **Technical Data and Specifications**
**High Current Terminal Block Relays (1PDT)**
|**Catalog Number**|**XRU1H12**|**XRU1H24**|**XRU1H24U**|**XRU1H120U**|
|---|---|---|---|---|
|**Replacement Relay**<br>Input voltage|**XRR1H12**<br>12 Vdc|**XRR1H24**<br>24 Vdc|**XRR1H24U**<br>24 Vac/Vdc|**XRR1H120U**<br>120 Vac/110 Vdc|
|**Connection Data**<br>Rigid solid AWG (mm2)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|
|Flexible stranded AWG (mm2)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|26–14 (0.14–2.5)|
|**Input Data for 1PDT Spring Cage Versions**|||||
|Input voltage|12 Vdc|24 Vdc|24 Vac/Vdc|120 Vac/110 Vdc|
|Permissible range|See**Page V7-T3-10**|See**Page V7-T3-10**|See**Page V7-T3-10**|See**Page V7-T3-10**|
|Typical input current|33 mA|18 mA|17.5 mA|4.5 mA (120 Vac)/4.2 mA (110 Vdc)|
|Typical response time<br>Typical release time|8 ms<br>10 ms|8 ms<br>10 ms|8 ms<br>10 ms|7 ms<br>10 ms|
|Input protection|Polarity protection diode,<br>free-wheeling diode|Polarity protection diode,<br>free-wheeling diode|Bridge rectifier|Bridge rectifier|
|**Output Data**<br>Contact type|Single contact, 1PDT|Single contact, 1PDT|Single contact, 1PDT|Single contact, 1PDT|
|Contact material|AgNi|AgNi|AgNi|AgNi|
|Max. switching voltage|250 Vac/Vdc1|250 Vac/Vdc1|250 Vac/Vdc1|250 Vac/Vdc1|
|Min. switching voltage|12 Vac/Vdc|12 Vac/Vdc|12 Vac/Vdc|12 Vac/Vdc|
|Limiting continuous current|10A2|10A2|10A2|10A2|
|Max. inrush current|30A (300 ms)|30A (300 ms)|30A (300 ms)|30A (300 ms)|
|Min. switching current<br>Min. switching power|100 mA<br>1.2W|100 mA<br>1.2W|100 mA<br>1.2W|100 mA<br>1.2W|
|**Miscellaneous Data**<br>Ambient temp range|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|–4° to 140°F (–20° to 60°C)|
|Rated operating mode|100% operating factor|100% operating factor|100% operating factor|100% operating factor|
|Inflammability class|V0, in accordance with UL 94|V0, in accordance with UL 94|V0, in accordance with UL 94|V0, in accordance with UL 94|
|Mechanical service life|3 x 107cycles|3 x 107cycles|3 x 107cycles|3 x 107cycles|
## _**Notes**_
- 1 The separating plate, XRAPLCESK, should be installed for voltages greater than 250V (L1, L2, L3) between identical terminal points of adjacent modules. Potential bridging is then possible with the XRAFBST bridge system.
- 2 The current rating for the normally open contact (#14) is 10A. The current rating for the normally closed contact (#12) is 6A and can be increased to 10A by bridging the two #12 contact connections.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-16**
Control Relays and Timers
3.2
XR Series Terminal Block Relays
## **Electrical Schematic**
## **High Current Terminal Block Relays**
**==> picture [150 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
A2 11<br>A1 14<br>12<br>**----- End of picture text -----**<br>
**3**
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **High Current Terminal Block Relays**
**==> picture [197 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.70 (94.0)<br>3.15 (80.0)<br>0.55 (14.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-17**
3.2
XR Series Terminal Block Relays
## Control Relays and Timers
## **XR Series Accessories**
## **Product Description**
## **Product Selection**
_**Power Terminal Block Bridges**_ **XR Series Accessories Standard Catalog 3 Color Pack Number 2-Position Snap-In Jumper 3** Red 10 **XRAFBST2RD 3** Blue 10 **XRAFBST2BU** Gray 10 **XRAFBST2GY 3 80-Position Snap-In Jumper** Red 5 **XRAFBST500RD 3** Blue 5 **XRAFBST500BU** ~~h~~ The XRAPLCESK power er Gray 5 **XRAFBST500GY 3** terminal block has the same **Power Terminal Block** shape as the relay modules **3** and is used to feed in the The XRAFBST colored, Gray 5 **XRAPLCESK** bridging potentials. The insulated plug-in bridge **End Cover** nominal current is 32A. When system reduces wiring **3** Black 5 **XRAATPBK** the total current is less than time by up to 70% compared or equal to 6A, supply can to conventionally wired **3** take place directly at the relays. The XRAFBST2, connecting terminal blocks of 2-position bridges, are **Technical Data and Specifications 3** one of the connected relays. suited for bridging a smaller number of relays and total **Power Terminal Block 3** _**End Cover**_ currents < ~~6~~ A. When a circuit **Description Specification** is supplied from both sides, **Connection Data** the circuit can be opened at **3** Rigid solid AWG (mm[2] ) 24–10 (0.2–4) any point, allowing all other modules to continue being Flexible stranded AWG (mm[2] ) 24–10 (0.2–4) **3** supplied at the same time. **Miscellaneous Data** The XRAFBST500 allow up Max. current 32A **3** to 80 modules to be bridged at one time. If bridges with Max. voltage 250 Vac[1] **3** different potentials meet in _**Note**_ neighboring modules, the 1 The separating plate, XRAPLCESK, should be installed for voltages greater than 250V end cover XRAATPBK **3** should be used. All bridges (L1, L2, L3) between identical terminal points of adjacent modules. Potential bridging is then possible with the XRAFBST bridge system. ~~A~~ are equipped with a groove **3** for removal with a standard screwdriver. The XRAATPBK end cover **3** is required at the start and stop of a relay strip. It can **3** also be used for visual separation of groups of **3** relays as well as separating relays with voltages greater **3** than 250V and separating neighboring bridges with different potentials. It is **3** equipped with pre-scored break out points at the **3** bridging positions so that individual bridges can be **3** passed through as needed. It may also be necessary to use the end cover between **3** adjacent relays when three phases (L1, L2, L3) are **3** used on the contact side of the relay.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-18**
Control Relays and Timers
3.3
EASY Intelligent Relays
**==> picture [245 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
EASY Intelligent Relays<br>o_O<br>**----- End of picture text -----**<br>
## **Product Overview**
The EASY Intelligent Relays combine timers, relays, counters, special functions, inputs and outputs into one compact device that is easily programmed. The EASY family of products provides an exception level of flexibility together with substantial savings of commissioning time and effort.
The EASY Intelligent Relays are available in more than 35 styles that support from 12 I/O up to a network of up to 320 I/O points providing the ideal solution for lighting, energy management, industrial control, irrigation, pump control, HVAC and home automation.
Once EASY products are installed, changes are easily accomplished through front panel programming, eliminating the need to change wiring and minimizing downtime.
## **Contents**
|**Contents**||**3**|
|---|---|---|
|**_Description_**<br>EASY Intelligent Relays<br>EASY500/700/800 Intelligent Relays . . . . . . . .<br>EASY/MFD Expansion Modules . . . . . . . . . . . .|**_Page_**<br>**V7-T3-20**<br>**V7-T3-25**|**3**<br>**3**|
|MFD Intelligent Relays . . . . . . . . . . . . . . . . . . .<br>EASY/MFD Communication Modules . . . . . . .<br>EASY/MFD Power Supplies, Accessories<br>and Software . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-28**<br>**V7-T3-33**<br>**V7-T3-36**|**3**<br>**3**|
|Drawings<br>Online<br>ewe||**3**|
## **Application Description**
The EASY Intelligent Relays excel in traditional applications where multiple relays, timers and pushbuttons are used. Applications span residential, commercial and industrial installations.
Typical control applications are:
- Car washes
- Automatic doors
- Commercial and residential lighting
- Pump control
- 12 Vdc automotive
- Greenhouse
- Machinery
- Irrigation
- Heating and air conditioning
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-19**
3.3
EASY Intelligent Relays
## Control Relays and Timers
**3**
## **EASY500/700/800 Intelligent Relays**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|EASY500/700/800 Intelligent Relays||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-21**|
|Technical Data and Specifications . . . . . . . . . . .|**V7-T3-22**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-23**|
|EASY/MFD Expansion Modules . . . . . . . . . . . . . .|**V7-T3-25**|
|MFD Intelligent Relays . . . . . . . . . . . . . . . . . . . . .|**V7-T3-28**|
|EASY/MFD Communication Modules . . . . . . .|**V7-T3-33**|
|EASY/MFD Power Supplies, Accessories||
|and Software . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-36**|
## **EASY500/700/800 Intelligent Relays**
## **Product Description**
Three families make up the EASY Intelligent Relay product line.
**EASY500 Series** —for
controlling small applications with up to 12 input/output signals. Models are available with and without displays. DIN rail mounted.
## **EASY700 Series** —for
controlling medium-sized applications with 20 I/O points (expandable to 40 I/O points). DIN rail mounted.
## **Standards and Certifications**
- EN 50178
- IEC/EN 60947
- UL
- CSA
> ● CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C
**Catalog Number Selection EASY500/700/800**
## **EASY7xx AC T C X**
**==> picture [223 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
Module Type Digital Inputs Display<br>EASY5xx = 500 Series AB = 24 Vac Blank = Display<br>EASY7xx = 700 Series AC = 110–240 Vdc X = No display<br>EASY8xx = 800 Series DA = 12 Vdc<br>DC = 24 Vdc<br>Clock<br>C = Clock<br>Blank = No clock<br>Digital Outputs<br>R = Relay<br>T = Transistor<br>**----- End of picture text -----**<br>
## **EASY800 Series** —for
controlling large-scale applications with 20 points, expandable to 40 points locally, and expandable using the **EASY-NET** network up to 320 I/O points. Models are available with and without displays. DIN rail mounted.
**Note:** Not all combinations are possible. See selection tables.
The **EASY-NET** integrated network provides easy and inexpensive linking of up to eight EASY800 devices over a distance of up to 1000 meters. Each EASY800 device can run its own program, or be used as a distributed input/output module. Connect up to eight controllers with up to 40 I/O to obtain 320 I/O.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-20**
Control Relays and Timers
3.3
EASY Intelligent Relays
## **Product Selection**
## **EASY500 Intelligent Relays**
||||||**Inputs**|||||||**Outputs**||**Catalog**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||**Description**|**24 Vac**|**110–240 Vac**|**12 Vdc**|**12 Vdc**|**24 Vdc**|**Analog**1||**Relay**|**Transistor**|**Number**|
|**EASY500 with Display**|**Display**<br>**EASY500 with Display**||||||||||||||
|||||12 I/O, no clock|—|8|—||—|—||4|—|**EASY512-AC-R**|
|rin|oy|||12 I/O, clock|—<br>8|—<br>—|—<br>—||8<br>—|2<br>2||4<br>4|—<br>—|**EASY512-DC-R**<br>**EASY512-AB-RC**|
||||||—|8|—||—|—||4|—|**EASY512-AC-RC**|
||||||—|—|8||—|2||4|—|**EASY512-DA-RC**|
||||||—<br>—|—<br>—|—<br>—||8<br>8|2<br>2||4<br>—|—<br>4|**EASY512-DC-RC**<br>**EASY512-DC-TC**|
|**EASY500 without**<br>**Display**|**EASY500 without**|||**No Display**<br>12 I/O, clock|8|—|—||—|2||4|—|**EASY512-AB-RCX**|
|Reesaasaeaa”<br>E:UN|||||—<br>—|8<br>—|—<br>8||—<br>—|—<br>2||4<br>4|—<br>—|**EASY512-AC-RCX**<br>**EASY512-DA-RCX**|
|eS|||||—|—|—||8|2||4|—|**EASY512-DC-RCX**|
||||||—|—|—||8|2||—|4|**EASY512-DC-TCX**|
|||||**EASY700 Intelligent Relays**<br>**Inputs**||||||||**Outputs**||**Catalog**|
|**EASY700 with Display**|**Description**<br>**Display**<br>**EASY700 with Display**||||**24 Vac**|**110–240 Vac**|**12 Vdc**|**12 Vdc**|**24 Vdc**|**Analog**1||**Relay**|**Transistor**|**Number**|
|||||18 I/O, clock|12|—|—||—|4||6|—|**EASY719-AB-RC**|
||||||—|12|—||—|—||6|—|**EASY719-AC-RC**|
|ee||||||—<br>~~a~~|—<br>~~a~~|12<br>~~a~~|~~a~~|—<br>~~a~~|4<br>~~a~~|~~a~~|6<br>~~a~~|—<br>~~a~~|**EASY719-DA-RC**<br>~~a~~|
|me<br>eeeeee||eee||—<br>—<br>—<br>12<br>4<br>6<br>—<br>**EASY719-DC-RC**<br>20 I/O, clock<br>—<br>—<br>—<br>12<br>4<br>—<br>8<br>**EASY721-DC-TC**<br> ~~eS~~|||||||||||
|**EASY700 without**<br>**Display**<br>pavereebiasis<br>E-GN<br>i||||**No Display**<br>18 I/O, clock|12<br>—<br>—<br>—<br>4<br>6<br>—<br>**EASY719-AB-RCX**<br>—<br>12<br>—<br>—<br>—<br>6<br>—<br>**EASY719-AC-RCX**<br>—<br>—<br>12<br>—<br>4<br>6<br>—<br>**EASY719-DA-RCX**<br>~~a~~<br>~~ee~~||||||||||
||||||—|—|—||12|4||6|—|**EASY719-DC-RCX**|
|||||20 I/O, clock|—|—|—||12|4||—|8|**EASY721-DC-TCX**|
|||||**EASY800 Intelligent Relays**|||||||||||
||||||**Inputs**|||||**Outputs**||||**Catalog**|
|||||**Description**|**110–240 Vac**|**24 Vdc**||**Analog**1||**Relay**|**Transistor**||**Analog**|**Number**|
|**EASY800 with Display**|**Display**<br>**EASY800 with Display**||||||||||||||
|Pri<br>Te<br>og<br>Sen<br>at||||18 I/O, clock<br>12<br>—<br>—<br>—<br>12<br>4<br>19 I/O, clock<br>—<br>12<br>4<br>20 I/O, clock<br>—<br>12<br>4<br>~~SSS ~~||||||6<br>—<br>—<br>**EASY819-AC-RC**<br>6<br>—<br>—<br>**EASY819-DC-RC**<br>6<br>—<br>1<br>**EASY820-DC-RC**<br>—<br>8<br>—<br>**EASY821-DC-TC**<br> ~~ee~~<br>~~Sees~~|||||
|||||21 I/O, clock|—|12||4||—|8||1|**EASY822-DC-TC**|
|**EASY800 without**|**EASY800 without**|||**No Display**|||||||||||
|**Display**|||.|18 I/O, clock|12|—||—||6|—|—<br>**EASY819-AC-RCX**<br>~~a~~|||
||||||—|12||4||6|—||—|**EASY819-DC-RCX**|
|F:1-N|||ort|19 I/O, clock<br>—<br>12<br>4<br> ~~TS ~~||||||6<br>—<br>1<br> ~~TT~~||||**EASY820-DC-RCX**|
|||||20 I/O, clock|—|12||4||—|8||—|**EASY821-DC-TCX**|
|||||21 I/O, clock|—|12||4||—|8||1|**EASY822-DC-TCX**|
**3**
## _**Note**_
1 Analog inputs optional. Use of analog inputs will result in a decrease in the same number of available digital inputs.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-21**
Control Relays and Timers
3.3
EASY Intelligent Relays
## **Technical Data and Specifications**
## **EASY500 Series**
**3**
|**EASY500 Series**||||||
|---|---|---|---|---|---|
|**Type**|**EASY512-AB…**|**EASY512-AC…**|**EASY512-DA…**|**EASY512-DC-R…**|**EASY512-DC-TC.**|
|Supply voltage|24 Vac|100–240 Vac|12 Vdc|24 Vdc|24 Vdc|
|Heat dissipation|5 VA|5 VA|2W|2W|2W|
|Continuous current outputs1|8A|8A|8A|8A|0.5A|
|Short-circuit proof with power factor 1<br>Short-circuit proof with power factor 0.7…0.7|Line protection B16, 600 A<br>Line protection B16, 900 A||||—<br>—|
|Mounting<br>Connection cables|On top-hat rail to DIN 50022, 35 mm or screw mounting with ZB4-101-GF1 fixing brackets|||||
|Solid|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|
|Flexible|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|
|Degree of protection|IP 20|IP 20|IP 20|IP 20|IP 20|
|RFI suppression|EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4|||||
|Ambient operating temperature|–25 to 55°C|–25 to 55°C|–25 to 55°C|–25 to 55°C|–25 to 55°C|
|Transport and storage temperature<br>Hazardous location|–40 to 70°C<br>–40 to 70°C<br>CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C||–40 to 70°C|–40 to 70°C|–40 to 70°C|
|**EASY700 Series**||||||
|**Type**<br>Supply voltage|**EASY719-AB…**<br>24 Vac|**EASY719-AC…**<br>100–240 Vac|**EASY719-DA…**<br>12 Vdc|**EASY719-DC-RC…**<br>24 Vdc|**EASY721-DC-TC.**<br>24 Vdc|
|Heat dissipation|7 VA|10 VA|3.5W|3.5W|3.5W|
|Continuous current outputs1|8A|8A|8A|8A|0.5A|
|Short-circuit proof with power factor 1|Line protection B16, 600A|Line protection B16, 600A|Line protection B16, 600A|Line protection B16, 600A|—|
|Short-circuit proof with power factor 0.7…0.7|Line protection B16, 900A|Line protection B16, 900A|Line protection B16, 900A|Line protection B16, 900A|—|
|Mounting|On top-hat rail to DIN 50022, 35 mm or screw mounting with ZB4-101-GF1 fixing brackets|||||
|Connection cables<br>Solid|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|
|Flexible<br>Degree of protection|0.2–2.5 mm2(AWG 22-12)<br>IP 20|0.2–2.5 mm2(AWG 22-12)<br>IP 20|0.2–2.5 mm2(AWG 22-12)<br>IP 20|0.2–2.5 mm2(AWG 22-12)<br>IP 20|0.2–2.5 mm2(AWG 22-12)<br>IP 20|
|RFI suppression|EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4|||||
|Ambient operating temperature|–25 to 55°C|–25 to 55°C|–25 to 55°C|–25 to 55°C|–25 to 55°C|
|Transport and storage temperature|–40 to 70°C|–40 to 70°C|–40 to 70°C|–40 to 70°C|–40 to 70°C|
|Hazardous location|CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C|||||
|**EASY800 Series**||||||
|**Type**|**EASY819-AC…**|**EASY819-DC-RC…**|**EASY820-DC-RC…**|**EASY821-DC-TC…**|**EASY822-DC-TC.**|
|Supply voltage<br>Heat dissipation|100–240 Vac<br>10 VA|24 Vdc<br>3.4W|24 Vdc<br>3.4W|24 Vdc<br>3.4W|24 Vdc<br>3.4W|
|Continuous current outputs1<br>Short-circuit proof with power factor 1|8A<br>Line protection B16, 600A|8A<br>Line protection B16, 600A|8A<br>Line protection B16, 600A|8A<br>Line protection B16, 600A|0.5A<br>—|
|Short-circuit proof with power factor 0.7…0.7|Line protection B16, 900A|Line protection B16, 900A|Line protection B16, 900A|Line protection B16, 900A|—|
|Mounting|On top-hat rail to DIN 50022, 35 mm or screw mounting with ZB4-101-GF1 fixing brackets|||||
|Connection cables||||||
|Solid|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|
|Flexible|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|
|Degree of protection<br>RFI suppression|IP 20<br>IP 20<br>EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4||IP 20|IP 20|IP 20|
|Ambient operating temperature<br>Transport and storage temperature|–25 to 55°C<br>–40 to 70°C|–25 to 55°C<br>–40 to 70°C|–25 to 55°C<br>–40 to 70°C|–25 to 55°C<br>–40 to 70°C|–25 to 55°C<br>–40 to 70°C|
|Hazardous location|CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C|||||
_**Note**_
> 1 Relay = 8A (10A to UL) with resistive load, 3A with inductive load. Transistor outputs = 0.5A/24 Vdc, maximum four outputs switchable in parallel.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-22**
Control Relays and Timers
3.3
EASY Intelligent Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **EASY500 Series, Drawing Number MD05013001E**
**3**
**==> picture [288 x 187] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.42 (10.8) 1.97 (50.0)<br>EASY500<br>3.54<br>(90.0)<br>1.77 4.02<br>(45.0) (102.0)<br>4.33<br>(110.0)<br>0.18 (4.5)<br>(M4) [ 0.157]<br>1.87 (47.5) (3.9) [Dia.] 1.41<br>2.22 (56.5) (35.8)<br>2.28 (58.0) 2.81 (71.5)<br>**----- End of picture text -----**<br>
## **EASY700 Series, Drawing Number MD05013002E**
**==> picture [296 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
EASY600 0.64 (16.3) 2.96 (75.0) 0.64 (16.3)<br>3.54<br>(90.0)<br>4.02<br>1.77 (102.0)<br>(45.0)<br>4.33<br>(110.0)<br>0.18 (4.5)<br>(M4) [ 0.157 ]<br>1.87 (47.5) (3.9) [Dia.]<br>2.22 (56.5) 4.23 (107.5)<br>2.28 (58.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-23**
Control Relays and Timers
3.3
## EASY Intelligent Relays
Approximate Dimensions in Inches (mm)
## **EASY800 Series, Drawing Number MD05013003E**
**3**
**==> picture [299 x 218] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.64 2.96 0.64<br>(16.3) (75.0) (16.3)<br>EASY800<br>3.54<br>(90.0)<br>4.02<br>1.77 (102.0)<br>(45.0)<br>4.33<br>(110.0)<br>0.18<br>(4.5) (M4) [ 0.157]<br>1.91 (3.9) [Dia.]<br>(48.5) 4.23<br>2.78 (107.5)<br>(70.5)<br>2.83<br>(72.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-24**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.3
EASY Intelligent Relays
## **EASY/MFD Expansion Modules**
## **Contents**
**==> picture [243 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Description|Page|
|EASY500/700/800 Intelligent Relays . . . . . . . . . . .|V7-T3-20|
|EASY/MFD Expansion Modules|
|Technical Data and Specifications . . . . . . . . . .|V7-T3-26|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-27|
|MFD Intelligent Relays . . . . . . . . . . . . . . . . . . . . .|V7-T3-28|
|EASY/MFD|Communication Modules . . . . . . .|V7-T3-33|
|EASY/MFD Power Supplies, Accessories|
|and Software . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-36|
**----- End of picture text -----**<br>
**3**
## **EASY/MFD Expansion Modules**
## **Product Description**
Expansion modules are available for increasing the input/output of the EASY700/ 800 and MFD intelligent relays to 24 inputs and up to 16 outputs. Expansion modules can be mounted directly to the EASY/MFD unit or up to 98 ft. (30 m) away using coupling module EASY200-EASY.
## **Product Selection**
## **EASY202-RE**
**EASY700/800/MFD I/O Expansion Modules**[1]
**==> picture [291 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Inputs|Outputs|Catalog|
|Description|110–240 Vac|24 Vdc|Relay|Transistor|Number|
|2 I/O expansion|—|—|2|—|EASY202-RE|
|18 I/O expansion|12|—|6|—|EASY618-AC-RE|
|—|12|6|—|EASY618-DC-RE|
|20 I/O expansion|—|12|—|8|EASY620-DC-TE|
|Coupling module for remote mounting of expansion modules|EASY200-EASY|
**----- End of picture text -----**<br>
## _**Note**_
1 All expansion modules include one EASY-LINK-DS.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-25**
3.3
## Control Relays and Timers
## EASY Intelligent Relays
## **Technical Data and Specifications**
## **EASY700/800/MFD I/O Expansion Modules**
**3**
|**Type**|**EASY202-RE**|**EASY618-AC-RE**|**EASY618-DC-RE**|**EASY620-DC-TE**|**EASY200-EASY**|
|---|---|---|---|---|---|
|Supply voltage|—|100 – 240 Vac|24Vac|24Vac|—|
|Heat dissipation<br>Continuous current outputs1|1W<br>8A|10 VA<br>8A|4W<br>8A|4W<br>0.5A|1W<br>—|
|Short-circuit proof with<br>power factor 1|Line protection<br>B16, 600A|Line protection<br>B16, 600A|Line protection<br>B16, 600A|Line protection<br>B16, 600A|—|
|Short-circuit proof with<br>power factor 0.7…0.7|Line protection<br>B16, 900A|Line protection<br>B16, 900A|Line protection<br>B16, 900A|Line protection<br>B16, 900A|—|
|Connection cables<br>Solid|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|
|Flexible|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|
|Degree of protection|IP20|IP20|IP20|IP20|IP20|
|RFI suppression|EN 55011, EN 55022 Class B, IEC 61000-6-1,2,3,4|||||
|Ambient operating temperature<br>Transport and storage temperature|–25° to 55ºC<br>–40° to 70ºC|–25° to 55ºC<br>–40° to 70ºC|–25° to 55ºC<br>–40° to 70ºC|–25° to 55ºC<br>–40° to 70ºC|–25° to 55ºC<br>–40° to 70ºC|
|Certification, standards|EN 50178, IEC/EN 60947, UL, CSA|||||
|Mounting|On top-hat rail to DIN 50022,|35 mm or screw mounting with|ZB4-101-GF1 fixing brackets|||
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-26**
Control Relays and Timers
3.3
EASY Intelligent Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **EASY600 Series, Drawing Number MD05013002E**
**==> picture [296 x 191] intentionally omitted <==**
**----- Start of picture text -----**<br>
EASY600 0.64 (16.3) 2.96 (75.0) 0.64 (16.3)<br>3.54<br>(90.0)<br>4.02<br>1.77 (102.0)<br>(45.0)<br>4.33<br>(110.0)<br>0.18 (4.5)<br>(M4) [ 0.157 ]<br>1.87 (47.5) (3.9) [Dia.]<br>2.22 (56.5) 4.23 (107.5)<br>2.28 (58.0)<br>**----- End of picture text -----**<br>
**3**
## **EASY202-RE/EASY200-EASY/EASY205-ASI Series, Drawing Number MD05013012E**
**==> picture [268 x 223] intentionally omitted <==**
**----- Start of picture text -----**<br>
EASY202-RE 0.30<br>EASY200-EASY (7.5)<br>EASY205-ASI<br>3.54<br>(90.0)<br>1.77 4.02<br>(45.0) (102.0)<br>4.33<br>(110.0)<br>0.18<br>(4.5)<br>(M4) [ 0.157]<br>1.87 (3.9) [Dia.] 0.30<br>(47.5) (7.5)<br>2.22 1.40<br>(56.5) (35.5)<br>2.28<br>(58.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-27**
Control Relays and Timers
3.3
EASY Intelligent Relays
**3**
**==> picture [65 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
MFD Intelligent Relays<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|EASY500/700/800 Intelligent Relays . . . . . . . . . . .|**V7-T3-20**|
|EASY/MFD Expansion Modules . . . . . . . . . . . . . .|**V7-T3-25**|
|MFD Intelligent Relays||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-29**|
|Technical Data and Specifications . . . . . . . . . .|**V7-T3-30**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-31**|
|EASY/MFD Communication Modules . . . . . . . . . .|**V7-T3-33**|
|EASY/MFD Power Supplies, Accessories||
|and Software . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-36**|
## **MFD Intelligent Relays**
## **Product Description**
MFD Intelligent Relays are comprised of three parts, a display, a controller, and an I/O module. Match each piece to the needs of your application. If you need to both monitor and modify parameters within your application, choose the MFD80-B. The preprogrammed and user programmable buttons give you the capability to make small changes to the way your application is running, start or stop a process, or change your program completely. Select a controller with or without **EASY-NET** support, and with AC or DC power. Finally, add the MFD I/O module that best suits your application.
**MFD Series** —for controlling small applications that require graphic visualization and for large-scale applications with 20 points, expandable to 40 points locally, and expandable using the **EASY-NET** network up to 320 I/O points. The MFD display can be linked to the EASY500/700/800 models to provide an enhanced text based operator interface. Panel mounted.
The **EASY-NET** integrated network provides easy and inexpensive linking of up to eight MFD devices over a distance of up to 1000 meters. Each MFD device can run its program, or be used as a distributed input/ output module. Connect up to eight controllers with up to 40 I/O to obtain 320 I/O.
## **Standards and Certifications**
- EN 50178
- IEC/EN 60947
- UL
- CSA
- CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-28**
Control Relays and Timers
3.3
EASY Intelligent Relays
## **Product Selection**
## **MFD-80-B**
**MFD-CP8**
## **MFD Displays (MFD-80)**
**==> picture [257 x 41] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Catalog|
|Description|Number|
|MFD, no buttons|MFD-80|
|MFD, buttons (shown)|MFD-80-B|
**----- End of picture text -----**<br>
## **MFD Controllers (MFD-CP8)**
**3**
**==> picture [376 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Catalog|
|Description|Number|
|MFD CPU with 24 Vdc, power supply, clock|MFD-CP8-ME|
|MFD CPU with 24 Vdc, power supply, clock, EASY-NET|MFD-CP8-NT|
|la|(|MFD CPU with 100–240 Vac, power supply, clock|MFD-AC-CP8-ME|
|MFD CPU with 100–240 Vac, power supply, clock, EASY-NET|MFD-AC-CP8-NT|
**----- End of picture text -----**<br>
## **MFD-R16**
## **MFD I/O Modules**
**==> picture [291 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Inputs|[1]|Outputs|Catalog|
|Description|110–240 Vac|24 Vdc|Analog|Relay|Transistor|Analog|Number|
|16 I/O|12|—|—|4|—|—|MFD-AC-R16|
|—|12|4|4|—|—|MFD-R16|
|—|12|4|—|4|—|MFD-T16|
|17 I/O|—|12|4|4|—|1|MFD-RA17|
|—|12|4|—|4|1|MFD-TA17|
**----- End of picture text -----**<br>
**MFD-CP4-800 Attached MFD Display to EASY Communication Modules (MFD-CP4)**[2] **to EASY-80 Display and EASY800 Unit Description**
**==> picture [292 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Catalog Number|
|MFD display to EASY500/700 DC communication module with EASY500/700 communication|MFD-CP4-500|
|cable (MFD-CP4-500-CAB5)|
|MFD display to EASY500/700 AC communication module with EASY500/700 communication|MFD-AC-CP4-500|
|cable (MFD-CP4-500-CAB5)|
|MFD display to EASY800 DC communication module with EASY800 communication cable|MFD-CP4-800|
|(MFD-CP4-800-CAB5)|
|MFD display to EASY800 AC communication module with EASY800 communication cable|MFD-AC-CP4-800|
|(MFD-CP4-800-CAB5)|
|Replacement communication module (all controllers—no cable)|MFD-CP4|
**----- End of picture text -----**<br>
**==> picture [249 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
MFD-80 + MFD-CP8 + MFD-I/O = MFD Assembly<br>**----- End of picture text -----**<br>
## _**Notes**_
For additional expansion, see EASY/MFD Expansion Modules on **Page V7-T3-26** .
- 1 Analog inputs optional.
- 2 Link MFD displays to EASY 500/700 or 800 intelligent relays for text only cabinet door installations.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-29**
Control Relays and Timers
3.3
## EASY Intelligent Relays
## **Technical Data and Specifications**
## **MFD-80, MFD-CP4, MFD-CP8**
**3**
|**MFD-80, MFD-CP4, MFD-CP8**|||
|---|---|---|
|**Type**|**MFD-80…**|**MFD-CP4/CP8**|
|Connection cables|||
|Solid|—|0.2–4.0 mm2(AWG 22-12)|
|Flexible<br>Degree of protection|—<br>IP 65|0.2–2.5 mm2(AWG 22-12)<br>IP 20|
|RFI suppression<br>Ambient operating temperature|EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4<br>Clearly legible at –5 to 50°C|EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4<br>–25 to 55°C|
|Transport and storage temperature|–40 to 70°C|–40 to 70°C|
|Hazardous location|CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C|CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C|
## **MFD I/O Modules**
|**Type**<br>Supply voltage|**MFD-AC-R16**<br>Supply via|**MFD-R16**<br>Supply via|**MFD-RA17**<br>Supply via|**MFD-T16**<br>Supply via|**MFD-TA17**<br>Supply via|
|---|---|---|---|---|---|
||MFD-CP8 module|MFD-CP8 module|MFD-CP8 module|MFD-CP8 module|MFD-CP8 module|
|Heat dissipation|0.5W|0.5W|0.5W|0.5W|0.5W|
|Continuous current outputs1<br>Short-circuit proof with|8A<br>Line protection|8A<br>Line protection|8A<br>Line protection|0.5A<br>—|0.5A<br>—|
|power factor 1<br>Short-circuit proof with|B16, 600A<br>Line protection|B16, 600A<br>Line protection|B16, 600A<br>Line protection|—|—|
|power factor 0.7…0.7<br>Connection cables|B16, 600A|B16, 600A|B16, 600A|||
|Solid<br>Flexible|0.2–4.0 mm2(AWG 22-12)<br>0.2–2.5 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)<br>0.2–2.5 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)<br>0.2–2.5 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)<br>0.2–2.5 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)<br>0.2–2.5 mm2(AWG 22-12)|
|Degree of protection|IP20|IP20|IP20|IP20|IP20|
|RFI suppression|EN 55011, EN 55022 Class B, IEC 61000-6-1,2,3,4|||||
|Ambient operating temperature|–25 to 55°C|–25 to 55°C|–25 to 55°C|–25 to 55°C|–25 to 55°C|
|Transport and storage temperature<br>Mounting|–40 to 70°C<br>Snap fitted to|–40 to 70°C<br>Snap fitted to|–40 to 70°C<br>Snap fitted to|–40 to 70°C<br>Snap fitted to|–40 to 70°C<br>Snap fitted to|
||MFD-CP8 module|MFD-CP8 module|MFD-CP8 module|MFD-CP8 module|MFD-CP8 module|
## **MFD-CP4 and CP8 Communication Modules**
|**Type**<br>Supply voltage|**MFD-80…**<br>Supply from -CP|**MFD-CP4-…**<br>24 Vdc|**MFD-CP8…**<br>**MFD-AC-CP8…**<br>24 Vdc<br>100–240 Vac|
|---|---|---|---|
|Heat dissipation|3W|1.5W|3W<br>8 VA|
|Mounting|Front mounting in 2 x 22.5 mm|Snap fitted to MFD-80|Snap fitted to MFD-80 or on top-hat rail to DIN 50022, 35 mm or screw|
||Standard drill holes||Mounting with ZB4-101-GF1 fixing brackets|
## _**Note**_
> 1 Relay = 8A with resistive load, 3A with inductive load. Transistor outputs = 0.5A/24 Vdc, maximum four outputs switchable in parallel.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-30**
Control Relays and Timers
3.3
EASY Intelligent Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **MFD-80 Series, Drawing Number MD05013005E**
**==> picture [452 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.89<br>MFD-80 (22.5) MFD-80<br>0.67<br>(17.0) 0.88 + 0.02<br>(22.3) + 0.4<br>1.26<br>(32.0)<br>1.18<br>(30.0)<br>3.41<br>(86.5) MFD-CP…<br>1.18 ± 0.01 0.79<br>(30.0) ± 0.2 (20.0) 1.18<br>1.11 1.11 0.54 (30.0)<br>(28.3) (28.3) (13.7)<br>2.44 Template for Holes, Scale 1:1<br>(62.0)<br>3.41<br>(86.5)<br>**----- End of picture text -----**<br>
**3**
## **MFD-CP8 Series, Drawing Number MD05013006E**
**==> picture [277 x 221] intentionally omitted <==**
**----- Start of picture text -----**<br>
MFD-CP8<br>0.64 2.95 0.640<br>(16.3) (75.0) (16.3)<br>3.54<br>(90.0)<br>0.18<br>1.18 ± 0.01 (4.5)<br>1.16<br>(30.0 ± 0.2)<br>(29.5)<br>1.53 1.53<br>(38.8) (38.8)<br>4.23<br>(107.5)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-31**
Control Relays and Timers
3.3
EASY Intelligent Relays
Approximate Dimensions in Inches (mm)
## **MFD-R/MFD-T I/O Module, Drawing Number MD05013007E**
**==> picture [325 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
MFD-R and MFD-T I/O<br>3<br>3<br>_ 3 SSS}<br>3.54<br>(90.0)<br>3<br>3<br>3 (19.0)0.75 0.98<br>3.47<br>| oR (25.0)<br>(88.1)<br>**----- End of picture text -----**<br>
## **MFD-CP4, MFD-80 and MFD-CP4 Series Combined, Drawing Number MD013013E**
**==> picture [432 x 219] intentionally omitted <==**
**----- Start of picture text -----**<br>
-0.24<br>1-6<br>(0.04) MFD-80<br>MFD-CP4<br>tr<br>N<br>0.81 1.70<br>(20.5) (43.2) MFD-CP4<br>N<br>| MFD-CP4 y y} |<br>| — ee 2.28<br>(58.0)<br>—[fooonnena_ |<br>0.89 0.89 1.43<br>(22.5) (22.5) (36.2)<br>1.08 1.18<br>(27.5) (30.0)<br>2.95<br>(75.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-32**
Control Relays and Timers
3.3
EASY Intelligent Relays
**EASY/MFD Communication Modules**
## **Contents**
**==> picture [243 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Page|
|EASY500/700/800 Intelligent Relays . . . . . . . . . . .|V7-T3-20|
|EASY/MFD Expansion Modules . . . . . . . . . . . . . .|V7-T3-25|
|MFD Intelligent Relays . . . . . . . . . . . . . . . . . . . . .|V7-T3-28|
|EASY/MFD|Communication Modules|
|Technical Data and Specifications . . . . . . . . . .|V7-T3-34|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-35|
|EASY/MFD Power Supplies, Accessories|
|and Software . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-36|
**----- End of picture text -----**<br>
**3**
## **EASY/MFD Communication Modules**
## **Product Description**
Five modules are available for easily connecting to worldstandard networks. The communication modules can be used with the EASY700/ 800 and MFD intelligent relays.
Available communication modules support:
## **Product Selection**
**EASY204-DP Communication Module**
## **EASY Communication Interface Modules**
**==> picture [281 x 79] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Catalog|
|Description|Number|
|PROFIBUS-DP slave interface module|EASY204-DP|
|AS-Interface slave with 4 in and 4 out interface module|EASY205-ASI|
|CANopen interface module|EASY221-CO|
|DeviceNet slave interface module|EASY222-DN|
|Ethernet Gateway|EASY209-SE|
**----- End of picture text -----**<br>
- PROFIBUS-DP
- AS-I (Actuator Sensor Interface) networks
- CANopen
- DeviceNet
- Ethernet (also compatible with EASY500)
All modules act as a gateway and operate exclusively as a slave station on the network.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-33**
3.3
## Control Relays and Timers
## EASY Intelligent Relays
## **Technical Data and Specifications**
## **EASY700/800/MFD Communication Interface Modules**
**3**
**EASY204-DP, EASY205-ASI, EASY221-CO, EASY222-DN, EASY209-SE**[1]
|**EASY204-DP, EASY205-ASI,**|**EASY221-CO, EASY222-DN, EASY209-SE**1|
|---|---|
|**Description**|**Specification**|
|Supply voltage|24 Vdc|
|Heat dissipation2|1W|
|Connection cables||
|Solid|0.2 – 4.0 mm2(AWG 22-12)|
|Flexible|0.2 – 2.5 mm2(AWG 22-12)|
|Degree of protection<br>RFI suppression|IP20<br>EN 55011, EN 55022 Class B, IEC 61000-6-1,2,3,4|
|Ambient operating temperature|–25° to 55ºC|
|Transport and storage temperature|–40° to 70ºC|
|Certification, standards|EN 50178, IEC/EN 60947, UL, CSA|
|Mounting|On top-hat rail to DIN 50022, 35 mm or screw mounting with ZB4-101-GF1 fixing brackets|
## _**Notes**_
> 1 EASY209-SE is also compatible with EASY500 Intelligent Relays.
> 2 EASY204-DP dissipates 2W.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-34**
Control Relays and Timers
3.3
EASY Intelligent Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **EASY202-RE/EASY200-EASY/EASY205-ASI/ EASY209-SE Series, Drawing Number MD05013012E**
**==> picture [230 x 222] intentionally omitted <==**
**----- Start of picture text -----**<br>
EASY202-RE 0.30<br>EASY200-EASY (7.5)<br>EASY205-ASI<br>3.54<br>(90.0)<br>1.77 4.02<br>(45.0) (102.0)<br>4.33<br>(110.0)<br>0.18<br>(4.5)<br>(M4) [ 0.157]<br>1.87 (3.9) [Dia.] 0.30<br>(47.5) (7.5)<br>2.22 1.40<br>(56.5) (35.5)<br>2.28<br>(58.0)<br>**----- End of picture text -----**<br>
**EASY204-DP Series, Drawing Number MD05013011E**
**==> picture [228 x 218] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.30<br>(7.5)<br>EASY204-DP<br>3.54<br>(90.0)<br>4.02<br>1.77<br>(102.0)<br>(45.0)<br>4.33<br>(110.0)<br>0.18<br>(4.5)<br>(M4) [ 0.157]<br>1.87 (3.9) [Dia.] 0.30<br>(47.5) 1.40 (7.5)<br>2.22 (35.5)<br>(56.5)<br>2.44<br>(62.0)<br>**----- End of picture text -----**<br>
**3**
**EASY221-CO/EASY222-DN Series, Drawing Number MD05013010E**
**==> picture [232 x 219] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.30<br>EASY221-CO (7.5)<br>(M4) [ 0.157]<br>EASY222-DN (3.9) [Dia.]<br>3.54<br>(90.0)<br>1.77 4.02<br>(45.0) (102.0)<br>4.33<br>(110.0)<br>0.18<br>(4.5)<br>1.87 0.30<br>(47.5) (7.5)<br>2.22 1.40<br>(56.5) (35.5)<br>2.64<br>(67.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-35**
3.3
EASY Intelligent Relays
## Control Relays and Timers
**3**
## **EASY/MFD Power Supplies, Accessories and Software**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|EASY500/700/800 Intelligent Relays . . . . . . . . . . .|**V7-T3-20**|
|EASY/MFD Expansion Modules . . . . . . . . . . . . . .|**V7-T3-25**|
|MFD Intelligent Relays . . . . . . . . . . . . . . . . . . . . .|**V7-T3-28**|
|EASY/MFD Communication Modules . . . . . . . . . .|**V7-T3-33**|
|EASY/MFD Power Supplies, Accessories||
|and Software||
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-37**|
|Technical Data and Specifications . . . . . . . . . .|**V7-T3-38**|
|Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-38**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-39**|
## **EASY/MFD Power Supplies, Accessories and Software**
## **Product Description**
## _**EASY/MFD Power Supplies**_
12 Vdc and 24 Vdc power supplies for applications where only 100–240 Vac is available.
## _**EASY/MFD Accessories**_
Memory modules, cables and other components to complete your automation solutions.
## _**EASYSoft Software**_
The EASYSoft software is used to program all of the EASY and MFD controllers - and displays. The Windows[®] based software provides straightforward circuit diagram input and editing and the diagrams can be displayed in the format desired. When EASY800 and MFD controllers are connected using EASY-NET, all connected devices can be accessed and their programs loaded from a single controller.
## **Product Selection**
**EASY Power Supplies**[1]
|**EASY Power Supplies**[1]||
|---|---|
||**Catalog**|
|**Description**<br>~~SSS~~|**Number**<br>~~SSS~~|
|100–240 Vac input to 12 Vdc at 20 mA/24 Vdc at 250 mA|**EASY200-POW**|
|100–240 Vac input to 24 Vdc at 1.25A|**EASY400-POW**|
|**_Note_**||
> 1 See Technical Data and Specifications on **Page V7-T3-38** for more information.
EASYSoft includes an integrated offline simulation tool that allows users to test a circuit diagram before commissioning.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-36**
Control Relays and Timers
3.3
EASY Intelligent Relays
## **Accessories**
## **EASY/MFD Memory Storage Modules**
|**EASY/MFD Memory Storage Modules**||
|---|---|
|**Description**|**Catalog Number**|
|EASY500/700 32K memory storage module|**EASY-M-32K**|
|EASY800/MFD 256K memory storage module|**EASY-M-256K**|
**3**
## **EASY/MFD Cables and Connectors**
|**EASY/MFD Cables and Connectors**||
|---|---|
|**Description**|**Catalog Number**|
|EASY500/700 to PC programming cable RS-232 from PC|**EASY-PC-CAB**|
|EASY800/MFD to PC programming cable RS-232 from PC|**EASY800-PC-CAB**|
|EASY500/700 to MFD-CP4 communication cable, 5m|**MFD-CP4-500-CAB5**|
|EASY800 to MFD-CP8 communication cable, 2m|**MFD-800-CAB**|
|EASY800 to MFD-CP8 communication cable, 5m|**MFD-800-CAB5**|
|EASY800 to MFD-CP4 communication cable, 5m|**MFD-CP4-800-CAB5**|
|EASY800/MFD EASY-NET cable, 0.3m networking cable|**EASY-NT-30**|
|EASY800/MFD EASY-NET cable, 0.8m networking cable|**EASY-NT-80**|
|EASY800/MFD EASY-NET cable, 1.5m networking cable|**EASY-NT-150**|
|EASY800/MFD network termination resistor, 2/pack|**EASY-NT-R**|
|EASY800/MFD EASY-NET cable (cable only, no connectors, see EASY-NT-RJ45), 100m|**EASY-NT-CAB**|
|RJ45 network connectors for EASY-NET cable (EASY-NT-CAB), 10/pack|**EASY-NT-RJ45**|
## **EASY/MFD Miscellaneous Parts**
**EASY700/500 Panel Window and Mounting Kit**
|**EASY/MFD Miscellaneous Parts**<br>**EASY700/500**<br>**Panel Window**|**EASY/MFD Miscellaneous Parts**<br>**EASY700/500**<br>**Panel Window**|**EASY/MFD Miscellaneous Parts**<br>**EASY700/500**<br>**Panel Window**|
|---|---|---|
|**Description**<br>**Catalog Number**<br>EASY500 relay simulator<br>**EASY412-DC-SIM-NA**<br>EASY500 panel window<br>**SKF-FF4**<br>EASY700/800 panel window<br>**SKF-FF6**<br>EASY500/700/800 panel window mounting kit to front mount units<br>**SKF-HA**<br>**Panel Window**<br>**and Mounting Kit**<br>~~By~~|||
||EASY/MFD panel mount brackets, 9/pack|**ZB4-101-GF1**|
||EASY/MFD grounding kit|**ZB4-102-KS1**|
||MFD display DIN rail mount kit|**MFD-TS144**|
||MFD display protective membrane cover|**MFD-XM-80**|
||MFD display protective plastic cover|**MFD-XS-80**|
||EASY/MFD six-channel high current input adapter1|**EASY256-HCI**|
||EASY/MFD spare interface connector, base to expander|**EASY-LINK-DS**|
||EASY starter kit (includes EASY512-DC-RC, EASY-PC-CAB, EASY412-DC-SIM-NA, EASYSoft)|**EASYSTARTKIT1**|
## _**EASY Software**_
**EASY Software**
## **EASY/MFD Software**
|**Description**<br>Programming software for EASY500/700/800 and MFD|Programming software for EASY500/700/800 and MFD|**Catalog Number**<br>**EASYSOFT**|
|---|---|---|
## _**Note**_
> 1 See Technical Data and Specifications on **Page V7-T3-38** for more information.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-37**
Control Relays and Timers
3.3
## EASY Intelligent Relays
## **Technical Data and Specifications**
## **EASY Power Supplies**
**3**
|**EASY Power Supplies**|||
|---|---|---|
|**Type**|**EASY200-POW**|**EASY400-POW**|
|Supply voltage|100–240 Vac|100–240 Vac|
|Maximum range|85–264 Vac|85–264 Vac|
|Output voltage<br>Output current (rated value)|24 Vdc (±3%)<br>0.25A|24 Vdc (±3%)<br>1.25A|
|Overcurrent limitation form<br>Short-circuit proof (secondary)|0.3A<br>Yes|1.4A<br>Yes|
|Overload proof|Yes|Yes|
|Potential isolation (prim/sec.)|Yes, SELV, (to EN 600950, VDE 805)|Yes, SELV, (to EN 600950, VDE 805)|
|Others|Additional output voltage 12 DC, 20 mA|Additional output voltage 12 DC, 20 mA|
|Connection cables<br>Solid|0.2–4.0 mm2(AWG 22-12)|0.2–4.0 mm2(AWG 22-12)|
|Flexible|0.2–2.5 mm2(AWG 22-12)|0.2–2.5 mm2(AWG 22-12)|
|Degree of protection|IP20|IP 20|
|RFI suppression|EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4|EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4|
|Ambient operating temperature|–25 to 55°C|–25 to 55°C|
|Transport and storage temperature|–40 to 70°C|–40 to 70°C|
|Mounting|On top-hat rail to DIN 50022, 35 mm or screw mounting with ZB4-101-GF1 fixing brackets||
## **Wiring Diagram**
## **EASY256-HCI**
**==> picture [265 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
L<br>N<br>> 1 A<br>S.. S..<br>N N 1 2<br>L N N I1 I2 I3 I4 I5 .....<br>115/230 Vh Input 115/230 Vh<br>EASY5..-AC-.. 3 4 5 6<br>EASY7..-AC-..<br>EASY256-HCI<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-38**
Control Relays and Timers
3.3
EASY Intelligent Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **EASY200-POW/EASY256-HCI and EASY400-POW Series, Drawing Number MD05013004E**
**==> picture [399 x 230] intentionally omitted <==**
**----- Start of picture text -----**<br>
EASY200-POW<br>EASY400-POW EASY256-HCI<br>0.42 1.97 0.30<br>(10.8) (50.0) (7.5)<br>3.54 3.54<br>(90.0) (90.0)<br>1.77 4.02 4.02<br>(45.0) (102.0) (102.0)<br>4.33 4.33<br>(110.0) (110.0)<br>0.18<br>(4.5)<br>1.87 1.41 (M4) [ .157] 0.30<br> (3.9) [Dia.]<br>(47.5) (35.8) (7.5)<br>2.22 2.81 1.40<br>(56.5) (71.5) (35.5)<br>**----- End of picture text -----**<br>
**3**
## **MFD-XS-80 and MFD-XM-80 Series, Drawing Number MD05013009E**
**MFD-XS-80 MFD-XM-80**
**==> picture [425 x 132] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.48<br>3.74<br>(88.5)<br>(95.0)<br>3.41 0.98 3.48 0.89<br>(86.5) (25.0) (88.5) (22.5)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-39**
Control Relays and Timers
3.3
## EASY Intelligent Relays
Approximate Dimensions in Inches (mm)
## **SKF-FF4 and SKF-FF6 Series, Drawing Number MD05013014E**
**3**
**==> picture [444 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
SKF-FF4 0.63 SKF-FF6 0.63<br>(16.0) (16.0)<br>2.99 2.99<br>(76.0) (76.0)<br>3.70 0.98 5.12 0.98<br>(94.0) (25.0) (130.0) (25.0)<br>**----- End of picture text -----**<br>
## **SKF-HA Series, Drawing Number MD05013015E**
**==> picture [172 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
SKF-HA<br>1.89<br>(48.0)<br>3.23<br>(82.0)<br>**----- End of picture text -----**<br>
**==> picture [85 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.43<br>(11.0)<br>2.60<br>(66.0)<br>**----- End of picture text -----**<br>
## **ZB4-101-GF1 Series**
**==> picture [78 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
* 3 fixing feet sufficient<br>**----- End of picture text -----**<br>
**==> picture [100 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fitting on 35 mm Top-Hat Rail<br>**----- End of picture text -----**<br>
**==> picture [247 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
* *<br>ZB4-101-GF1<br>* *<br>Fitting on Mounting Plate (Horizontal)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-40**
Control Relays and Timers
3.3
EASY Intelligent Relays
Approximate Dimensions in Inches (mm)
## **ZB4-102-KS1 Series— Grounding the Screen for Top-Hat Rail**
## **ZB4-102-KS1 Series— Grounding the Screen for Mounting Plate**
## **EASY412-DC-SIM-NA Series**
**==> picture [143 x 76] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection<br>Cable<br>= ©<br>Connect<br>ooU [ONS Outputs<br>Digital<br>OOOO Inputs<br>**----- End of picture text -----**<br>
**==> picture [77 x 180] intentionally omitted <==**
**----- Start of picture text -----**<br>
DEL ALT<br>eZ<br>ie ESC OK<br>eo) e) [e)<br>Power<br>Supply<br>Unit<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-41**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
## **General Purpose Plug-In Relay**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D1PR/D1PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-46**|
|D2PR/D2PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-51**|
|D3PR/D3PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-61**|
|D4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-71**|
|D5PR/D5PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-75**|
|D7PR/D7PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-85**|
|D8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-100**|
|D9 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-106**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-110**|
## **Product Selection Guide**
## **General Purpose Relay Selection Characteristics**
- Current rating: 1A–30A
- Specifications: CSA, CE, IEC, NEMA, UL, etc.
- Contact arrangement: SPDT, DPDT, 3PDT, 4PDT, ● Other: Physical etc. dimensions, maximum
- ● Coil voltage: 6V–240 Vac/ voltage, mechanical/ 6V–110 Vdc electrical life, etc.
- Coil voltage: 6V–240 Vac/ 6V–110 Vdc
- Mounting options: socket, flange, DIN rail, panel
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-42**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
|**General Purpose Plug-In Relays**<br>**Relay Series**<br>**D1PR/D1PF**|**General Purpose Plug-In Relays**<br>**Relay Series**<br>**D1PR/D1PF**|**General Purpose Plug-In Relays**<br>**Relay Series**<br>**D1PR/D1PF**|||**D2PR/D2PF**|**D2PR/D2PF**|**D2PR/D2PF**|||**D3PR/D3PF**|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Approvals**|||||||||||||
||ROHS|cwehus|C~~E~~|@&||ROHS|cwAhus|C~~E~~|&|ROHS<br>cWAhus|C~~E~~|&|
|**Features**|Polycarbonate cover||||Polycarbonate cover|||||Polycarbonate cover|||
||Indicator lamp and pushbutton available|Indicator lamp and pushbutton available|||Indicator lamp and pushbutton available||Indicator lamp and pushbutton available|||Indicator lamp and pushbutton available|||
||Panel and DIN mounting||||Panel, DIN and flange mounting|||||Panel and DIN mounting|||
||||||Latching|||||8- or 11-pin octal plug-in|||
|**Contact Data**||||||||||Latching (D3PR version)|||
|Configuration|**SPDT**||||**DPDT**||**DPDT Latching**|**DPDT Latching**|**4PDT**|**DPDT**||**3PDT**|
|Max. allowable load|20A||||10A||10A||10A|16A<br>16A||16A|
|Material|Silver alloy||||Silver alloy|||||Silver alloy|||
|Dielectric strength|1500V||||1500V|||||1500V|||
|between poles|||||||||||||
|**Coil Data**|||||||||||||
|AC|6 to 240 Vac||||6 to 240 Vac|||||6 to 240 Vac|||
|DC|6 to 110 Vdc||||6 to 110 Vdc|||||6 to 110 Vdc|||
|Power|||||||||||||
|VA (Vac)|0.9 VA||||1.2 VA|||||3 VA 1.4W (D3PR and D3PF)|||
|Watts (Vdc)|0.7W||||0.9W|||||2 VA 1.64W (D3PR5 latching)|||
|**General Data**|||||||||||||
|Ambient temperature|||||||||||||
|Storage|–40° to 185°F (–40° to 85°C)||||–40° to 185°F (–40° to 85°C)|||||–40° to 185°F (–40° to 85°C)|||
|Operational<br>Response time|–40° to 131°F (–40° to 55°C)<br>20 milliseconds||||–40° to 131°F (–40° to 55°C)<br>20 milliseconds|||||–40° to 131°F (–40° to 55°C)<br>20 milliseconds|||
|Life|||||||||||||
|Mechanical operations|10 million||||10 million|||||5 million (D3PR and D3PF)|||
|||||||||||10 million (D3PR5 latching)|||
|Electrical operations|100,000||||200,000|||||100,000|||
|**Page Numbers**|**V7-T3-46**to**V7-T3-50**||||**V7-T3-51**to**V7-T3-60**|||||**V7-T3-61**to**V7-T3-70**|||
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-43**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**==> picture [516 x 461] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|General Purpose Plug-In Relays, continued|
|3|
|Relay Series|D4|D5PR/D5PF|D7PR/D7PF|
|3|
|3|
|3|
|3|
|3|Approvals|
|3|
|Features|
|3|
|Polycarbonate cover|Polycarbonate cover|Polycarbonate cover|
|3|Indicator lamp available|Indicator lamp and pushbutton available|Indicator lamp and pushbutton available|
|Panel and DIN mounting|Panel, DIN and flange mounting|Panel and DIN mounting|
|3|Socket has built-in hold-down spring|
|Contact Data|
|3|Configuration|SPDT|DPDT|DPDT|3PDT|SPDT|DPDT|3PDT|4PDT|
|3|Max. allowable load|10A at 250 Vac|5A at 240 Vac|16A|16A|20A|15A|15A|15A|
|Material|AgCdO|Silver alloy|Silver alloy|
|3|Dielectric strength|5000V|1500V|1500V|1500V|2500V|2500V|
|Coil Data|
|3|AC|6 to 240 Vac|6 to 240 Vac|6 to 240 Vac|
|DC|6 to 110 Vdc|6 to 110 Vdc|6 to 110 Vdc|
|3|
|Power|
|3|VA (Vac)|0.9 VA|3 VA|1.2 VA|1.2 VA|1.5 VA|1.5 VA|
|Watts (Vdc)|0.5W|1.4W|0.9W|0.9W|1.4W|1.5W|
|3|General Data|
|Ambient temperature|
|3|Storage|–40° to 158°F (–40° to 70°C)|–40° to 185°F (–40° to 85°C)|–40° to 185°F (–40° to 85°C)|
|3|Operational|–40° to 158°F (–40° to 70°C)|–40° to 131°F (–40° to 55°C)|–40° to 131°F (–40° to 55°C)|
|Response time|15 milliseconds|20 milliseconds|20 milliseconds (30 milliseconds for latching)|
|3|Life|
|Mechanical operations|10 million|5 million|10 million|
|3|Electrical operations|100,000|100,000|100,000|100,000|200,000|200,000|
|Page Numbers|V7-T3-71|to|V7-T3-74|V7-T3-75|to|V7-T3-84|V7-T3-85|to|V7-T3-99|
**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-44**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **General Purpose Plug-In Relays, continued**
|**Relay Series**|**D8**|||**D9**|**D9**||
|---|---|---|---|---|---|---|
|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|
|**Approvals**|||||||
||||||||
|**Features**|||||||
||Dust cover|||Dust cover|||
||Panel, DIN and flange mounting<br>Pushbutton available||||||
||Quick-connect and screw terminals<br>Panel mounting||||||
|||||Screw terminals|||
|**Contact Data**|||||||
|Configuration||||**4PST**|||
||**SPST-NO**||**DPST-NO**<br>**NO**|||**NC**|
|Max. allowable load|30A at||25A at<br>25A at|||8A at|
||220 Vac||220 Vac<br>220 Vac|||220 Vac|
|Material|AgCdO|||AgCdO|||
|Dielectric strength|4000V|||4000V|||
|**Coil Data**|||||||
|AC|6 to 240 Vac|6 to 240 Vac||24 to 240 Vac|||
|DC|12 to 24 Vdc|12 to 24 Vdc||12 to 110 Vdc|||
|Power|||||||
|VA (Vac)|2.5 VA|||2.6 VA|||
|Watts (Vdc)|1.9W|||2.0W|||
|**General Data**|||||||
|Ambient temperature|||||||
|Storage|–4° to 185°F (–20° to 85°C)|||–13° to 140°F (–25° to 60°C)|||
|Operational|–4° to 131°F (–20° to 55°C)|||–13° to 140°F (–25° to 60°C)|||
|Response time|30 milliseconds|||50 milliseconds|||
|Life|||||||
|Mechanical operations|5 million|||1 million|||
|Electrical operations|100,000|||100,000|||
|**Page Numbers**|**V7-T3-100**to**V7-T3-105**|||**V7-T3-106**to**V7-T3-109**|||
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-45**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
## **D1 Series Relay**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D1PR/D1PF Series||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-47**|
|Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-48**|
|Technical Data and Specifications . . . . . . . . . . .|**V7-T3-49**|
|Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-50**|
|Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-50**|
|D2PR/D2PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-51**|
|D3PR/D3PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-61**|
|D4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-71**|
|D5PR/D5PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-75**|
|D7PR/D7PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-85**|
|D8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-100**|
|D9 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-106**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-110**|
## **D1PR/D1PF Series**
## **Product Description**
The D1 Series of relay provides a compact singlepole relay capable of handling 20A. Multiple feature and voltage options allow for the perfect fit for any application.
## **Features**
## _**D1PR**_
- Compact relay capable of breaking relatively large load currents
- Panel and DIN rail mounting
## _**D1PF**_
- The contact operation can be easily checked by Push-to-Test button
- Flag indicator shows relay status in manual or powered condition
- LED status lamp shows coil ON or OFF status— ideal for use in low light applications
- Push-to-Test button allows for manual operation of relay without the need for coil power
- Lock-down door holds pushbutton and contacts in the operate position when activated
## **Standards and Certifications**
- When used with accompanying Eaton
- **UL Listed** screw terminal socket. **Catalog Number Selection**
## **D1PR/D1PF Series**
||**D 1 P F**|**D 1 P F**|**D 1 P F**|**1**|**1**|**A**|**A**||**A**|**A**|**A**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||
|||||||||||||
|**Family Type**|||||||||||**Coil Voltage**|
|**D1PF**|||||||||||**A**= 120 Vac|
|D1PR|||||||||||**A1**= 110 Vdc<br>**B**= 240 Vac|
|**Contact Configuration**|||||||||||**P**= 6 Vac<br>**P1**= 6 Vdc|
|**1**= SPDT|||||||||||**R**= 12 Vac|
||||||||||||**R1**= 12 Vdc|
||**Standard Features**||||||||||**T**= 24 Vac<br>**T1**= 24 Vdc|
|**Blank**=|Mechanical flag indicator||||||||||**W**= 48 Vac|
||(only with D1PR)||||||||||**W1**= 48 Vdc|
|**A**=|LED test button, flag indicator,|||||||||||
||lock-down door, finger-grip cover,|||||||||||
||ID tag (only with D1PF)|||||||||||
|**1**=|LED and mechanical flag indicator|||||||||||
- Finger-grip cover allows operator to remove relays from sockets easily
- ID tag/write label to identify relays in multiplerelay circuits
- Bipolar LED allows for reverse polarity applications
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-46**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Product Selection**
## **D1PR/D1PF Relay/Socket Quick Reference**
|**Relay**|||**Module**|**ID**||
|---|---|---|---|---|---|
|**Type**|**Socket**|**Clip**|**Type**|**Tag**|**Jumper**|
|D1PR1|D1PAA|PMC-1781|B|—|—|
|D1PF1|D1PAA|PMC-1781|B|—|—|
## **D1PR/D1PF Series**
## **D1PF Series Relay**
**3**
|**Coil**<br>**Voltage**<br>**Contact**<br>**Configuration**<br>**Coil Resistance**<br>**(Ohms)**<br>**Catalog**<br>**Number**<br>**Full Featured**<br>6 Vac<br>SPDT<br>12.2<br>**D1PF1AP**<br>6 Vdc<br>SPDT<br>47<br>**D1PF1AP1**<br>12 Vac<br>SPDT<br>46<br>**D1PF1AR**<br>12 Vdc<br>SPDT<br>188<br>**D1PF1AR1**<br>~~SS~~|**Coil**<br>**Voltage**<br>**Contact**<br>**Configuration**<br>**Coil Resistance**<br>**(Ohms)**<br>**Catalog**<br>**Number**<br>**Full Featured**<br>6 Vac<br>SPDT<br>12.2<br>**D1PF1AP**<br>6 Vdc<br>SPDT<br>47<br>**D1PF1AP1**<br>12 Vac<br>SPDT<br>46<br>**D1PF1AR**<br>12 Vdc<br>SPDT<br>188<br>**D1PF1AR1**<br>~~SS~~|**Coil**<br>**Voltage**<br>**Contact**<br>**Configuration**<br>**Coil Resistance**<br>**(Ohms)**<br>**Catalog**<br>**Number**<br>**Full Featured**<br>6 Vac<br>SPDT<br>12.2<br>**D1PF1AP**<br>6 Vdc<br>SPDT<br>47<br>**D1PF1AP1**<br>12 Vac<br>SPDT<br>46<br>**D1PF1AR**<br>12 Vdc<br>SPDT<br>188<br>**D1PF1AR1**<br>~~SS~~|**Coil**<br>**Voltage**<br>**Contact**<br>**Configuration**<br>**Coil Resistance**<br>**(Ohms)**<br>**Catalog**<br>**Number**<br>**Full Featured**<br>6 Vac<br>SPDT<br>12.2<br>**D1PF1AP**<br>6 Vdc<br>SPDT<br>47<br>**D1PF1AP1**<br>12 Vac<br>SPDT<br>46<br>**D1PF1AR**<br>12 Vdc<br>SPDT<br>188<br>**D1PF1AR1**<br>~~SS~~|
|---|---|---|---|
|24 Vac 50/60 Hz|SPDT|180|**D1PF1AT**|
|24 Vdc|SPDT|750|**D1PF1AT1**|
|48 Vac|SPDT|720|**D1PF1AW**|
|48 Vdc|SPDT|2600|**D1PF1AW1**|
|110 Vdc|SPDT|13,800|**D1PF1AA1**|
|120 Vac 50/60 Hz|SPDT|4430|**D1PF1AA**|
|240 Vac 50/60 Hz|SPDT|15,720|**D1PF1AB**|
|**Plain Cover with LED Indicator**||||
|6 Vac|SPDT|12.2|**D1PR11P**|
|6 Vdc|SPDT|47|**D1PR11P1**|
|12 Vac|SPDT|46|**D1PR11R**|
|12 Vdc|SPDT|188|**D1PR11R1**|
|24 Vac 50/60 Hz|SPDT|180|**D1PR11T**|
|24 Vdc|SPDT|750|**D1PR11T1**|
|48 Vac|SPDT|720|**D1PR11W**|
|48 Vdc|SPDT|2600|**D1PR11W1**|
|240 Vac 50/60 Hz|SPDT|15,720|**D1PR11B**|
|110 Vdc|SPDT|13,800|**D1PR11A1**|
|120 Vac|SPDT|4430|**D1PR11A**|
|24 Vac 50/60 Hz|SPDT|180|**D1PR1T**|
|**Plain Cover**||||
|6 Vac|SPDT|12.2|**D1PR1P**|
|6 Vdc|SPDT|47|**D1PR1P1**|
|12 Vac|SPDT|46|**D1PR1R**|
|12 Vdc|SPDT|188|**D1PR1R1**|
|24 Vdc|SPDT|750|**D1PR1T1**|
|48 Vac|SPDT|720|**D1PR1W**|
|48 Vdc|SPDT|2600|**D1PR1W1**|
|110 Vdc|SPDT|13,800|**D1PR1A1**|
|120 Vac 50/60 Hz|SPDT|4430|**D1PR1A**|
|240 Vac|SPDT|15,270|**D1PR1B**|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-47**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Accessories**
## **D1PR/D1PF Sockets and Accessories**
**3**
|**Type**|**Module**<br>**Size**<br>**Nominal Voltage**<br>**(Max. for Sockets)**<br>**Nominal**<br>**Current**<br>**Mounting Style**<br>**Wire Size**<br>**Wire**<br>**Connection**<br>**Standard**<br>**Pack**<br>**Catalog**<br>**Number**|
|---|---|
|Socket|B<br>300<br>20<br>Panel/DIN rail<br>12 /14 (2) AWG, 4 /2.5 (2) mm2<br>Screw clamping<br>10<br>**D1PAA**1|
|Flange mount adapter|—<br>—<br>—<br>Flange<br>—<br>—<br>25<br>**PFC-D11**|
|Metal spring clip|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PMC-1781**|
|Protection diode|B<br>6 to 250 Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BD250**|
|LED indicator|B<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BLG24**|
||B<br>120/240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BLG240**|
|MOV suppressor|B<br>120 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BMV120**|
||B<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BMV24**|
||B<br>240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BMV240**|
|Plastic DIN rail end stop|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PFP-P**|
_**Note**_
> 1 Protection Category (Finger Safe), EN 60529: IP20.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-48**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Technical Data and Specifications**
## **D1PF/D1PR Relay Specifications**
|**D1PF/D1PR Relay Specifications**||
|---|---|
|**Description**|**D1PR**<br>**D1PF**|
|**Contact Characteristics**||
|Contact rating|20A<br>20A|
|Terminal style|Plug-in<br>Plug-in|
|Contact materials|Silver alloy<br>Silver alloy|
|Maximum switching voltage|300V<br>300V|
|Switching current at voltage—resistive|20A at 120 Vac 50/60 Hz<br>20A at 120 Vac 50/60 Hz|
||20A at 277 Vac 50/60 Hz<br>20A at 277 Vac 50/60 Hz|
||20A at 28 Vdc<br>20A at 28 Vdc|
|Switching current at voltage|1/2 hp at 120 Vac<br>1/2 hp at 120 Vac|
||1 hp at 277 Vac<br>1 hp at 277 Vac|
|Pilot duty|B300<br>B300|
|Minimum switching requirement|100 mA at 5 Vdc (0.5W)<br>100 mA at 5 Vdc (0.5W)|
|**Coil Characteristics**||
|Operating range<br>% of nominal (AC)<br>% of nominal (DC)<br>Average consumption|85 to 110%<br>85 to 110%|
||80 to 110%<br>80 to 110%|
||0.9 VA<br>0.9 VA|
||0.7W<br>0.7W|
|Dropout voltage threshold|15% (AC)<br>15% (AC)|
||10% (DC)<br>10% (DC)|
|**Performance**||
|Electrical life (UL 508) operations at rated current|100,000 operations<br>100,000 operations|
|Mechanical life operations unpowered|10,000,000 operations<br>10,000,000 operations|
|Response time|20 ms<br>20 ms|
|Dielectric strength<br>Between coil and contact Vac (rms)|2500V (rms)<br>2500V (rms)|
|Between poles Vac (rms)|1500V (rms)<br>1500V (rms)|
|**Environment**||
|Ambient air temperature around the device<br>Storage|–40° to 131°F (–40° to 55ºC)<br>–40° to 131°F (–40° to 55°C)|
|Operation|–40° to 185°F (–40° to 85ºC)<br>–40° to 185°F (–40° to 85°C)|
|Vibration resistance—operational|3 g-n at 10–55 Hz<br>3 g-n at 10–55 Hz|
|Shock resistance|10 g-n<br>10 g-n|
|Degree of protection|IP40<br>IP40|
|**Features**||
|Cover options|Plain cover<br>Full featured|
|Features|Mechanical flag indicator (optional LED)<br>Locking pushbutton/<br>Bipolar LED/<br>Removable ID tag/<br>Mechanical flag indicator|
|Product certifications|RoHS/UL/CE/CSA<br>RoHS/UL/CE/CSA|
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-49**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Wiring Diagram**
## **D1PF/D1PR**
**3**
**==> picture [223 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 1<br>14 5<br>11 9<br>A1 A2 13 14<br>IEC NEMA<br>**----- End of picture text -----**<br>
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D1PF/D1PR**
**==> picture [392 x 358] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.10 0.53 0.53<br>(2.1) (14.0) (14.0)<br>1.10 1.10<br>(27.9) (27.9)<br>1.60 1.40<br>(40.6) (35.5)<br>D1PAA<br>1.18<br>(30.0)<br>0.74 0.67<br>(19.0) (17.0) 14 5<br>12 1<br>1 1<br>N.C. N.C.<br>5 5<br>0.16 N.O. N.O.<br>(80.0)3.14 (4.0) 9 COM 9 COM<br>14 13 14 13<br>3.33 Input Input<br>(84.0)<br>Module Module<br>1.57 Input Input<br>(40.0)<br>A2 A1 Input 14 13 Input<br>Input Input<br>11 9<br>0.82 IEC NEMA<br>(21.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-50**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**==> picture [47 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
D2 Series Relay<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||**3**|
|---|---|---|
|**_Description_**|**_Page_**||
|D1PR/D1PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-46**|**3**|
|D2PR/D2PF Series|||
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V7-T3-52**|**3**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .<br>Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-52**<br>**V7-T3-54**|**3**|
|Technical Data and Specifications . . . . . . . . . . .<br>Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-55**<br>**V7-T3-56**|**3**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>D3PR/D3PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-57**<br>**V7-T3-61**|**3**|
|D4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>D5PR/D5PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-71**<br>**V7-T3-75**|**3**|
|D7PR/D7PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-85**|**3**|
|D8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-100**||
|D9 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-106**|**3**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-110**||
## **D2PR/D2PF Series**
## **Product Description**
The D2 Series is a compact line of relays with quick response time and long life. Available in DPDT, 4PDT and DPDT latching configurations.
## **Features**
## _**D2PR**_
- Ultra-high sensitivity relay with quick response
- High reliability, long life
- Panel, DIN rail and flange mounting
- Small size
## _**D2PF**_
- Flag indicator shows relay status in manual or powered condition
- Bipolar LED status lamp allows for reverse polarity applications
## **Standards and Certifications**
- When used with accompanying Eaton
- **UL Listed** screw terminal socket.
- Shows coil ON or OFF status
- Ideal in low light conditions
- Color-coded pushbutton identifies AC coils with red or DC coils with blue pushbuttons
- Allows for manual operation of relay without the need for coil power
- Ideal for field service personnel to test control circuits
- Lock-down door, when activated, holds pushbutton and contacts in the operate position
- Excellent for analyzing circuit problems
- Finger-grip cover allows operator to remove relays from sockets more easily than conventional relays
- White plastic ID tag/write label used for identification of relays in multi-relay circuits
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-51**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Catalog Number Selection**
## **D2PF/D2PR**[1]
**3**
**==> picture [205 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
D 2 P F 2 A A<br>Family Type Coil Voltage<br>D2PF A = 120 Vac<br>D2PR A1 = 110 Vdc<br>B = 240 Vac<br>P = 6 Vac<br>Contact Configuration P1 = 6 Vdc<br>2 = DPDT R = 12 Vac<br>4 = 4PDT R1 = 12 Vdc<br>5 = DPDT latching T = 24 Vac<br>T1 = 24 Vdc<br>W = 48 Vac<br>Standard Features W1 = 48 Vdc<br>Blank = Plain cover (only with D2PR)<br>A = LED test button, flag indicator,<br>lock-down door, finger-grip cover,<br>ID tag (only with D2PF)<br>**----- End of picture text -----**<br>
## **Product Selection**
## **D2PF/D2PR Relay/Socket Quick Reference**
|**Relay**<br>**Type**|**Socket**|**Clip**<br>**Module**<br>**Type**<br>**ID**<br>**Tag**<br>**Jumper**|
|---|---|---|
|D2PR2, D2PF2|D2PAL|PWC-D24<br>B<br>PWF-D2P<br>D2PJ1|
|||PQC-1782<br>—<br>—<br>—|
||D2PA6|PQC-1342<br>None<br>—<br>—|
|D2PR4, D2PF4|D2PAP|PWC-D24<br>B<br>PWF-D2P<br>D2PJ1|
|||PQC-1782<br>—<br>—<br>—|
||D2PA7|PWC-D24<br>B<br>—<br>—|
|||PQC-1782<br>B<br>—<br>—|
||D2PA6|PQC-1342<br>None<br>—<br>—|
|D2PR5|D2PA4|PYC-A1<br>None<br>—<br>—|
## _**Note**_
> 1 For deciphering catalog numbers. Do not use for ordering as not all combinations are readily available.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-52**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **D2PF Series Relay**
## **D2PF/D2PR Series**
|**Coil**|**Contact**|**Coil Resistance**|**Catalog**|
|---|---|---|---|
|**Voltage**|**Configuration**|**(Ohms)**|**Number**|
|**Full Featured Style**<br> ~~SS~~||||
|6 Vac|DPDT|9.6|**D2PF2AP**|
|6 Vdc|DPDT|40|**D2PF2AP1**|
|12 Vac|DPDT|46|**D2PF2AR**|
|12 Vdc|DPDT|160|**D2PF2AR1**|
|c<br>~~ce~~|~~ce~~|~~ce~~|~~ce~~|
|24 Vac|DPDT|180|**D2PF2AT**|
|24 Vdc|DPDT|650|**D2PF2AT1**|
|48 Vdc|DPDT|2600|**D2PF2AW1**|
|110/125 Vdc|DPDT|11,000|**D2PF2AA1**|
|120 Vac|DPDT|4430|**D2PF2AA**|
|220/240 Vac|DPDT|15,720|**D2PF2AB**|
|12 Vac|4PDT|46|**D2PF4AR**|
|12 Vdc|4PDT|160|**D2PF4AR1**|
|24 Vac|4PDT|180|**D2PF4AT**|
|24 Vdc|4PDT|650|**D2PF4AT1**|
|48 Vdc|4PDT|2600|**D2PF4AW1**|
|110/125 Vdc|4PDT|11,000|**D2PF4AA1**|
|120 Vac|4PDT|4430|**D2PF4AA**|
|220/240 Vac|4PDT|15,720|**D2PF4AB**|
|**Plain Cover Style**||||
|6 Vdc|DPDT|40|**D2PR2P1**|
|12 Vdc|DPDT|160|**D2PR2R1**|
|24 Vac|DPDT|180|**D2PR2T**|
|24 Vdc|DPDT|650|**D2PR2T1**|
|48 Vdc|DPDT|2600|**D2PR2W1**|
|110/125 Vdc|DPDT|11,000|**D2PR2A1**|
|120 Vac|DPDT|4430|**D2PR2A**|
|220/240 Vac|DPDT|15,720|**D2PR2B**|
|6 Vac|4PDT|9.6|**D2PR4P**|
|6 Vdc|4PDT|40|**D2PR4P1**|
|12 Vac|4PDT|46|**D2PR4R**|
|12 Vdc|4PDT|160|**D2PR4R1**|
|24 Vac|4PDT|180|**D2PR4T**|
|24 Vdc|4PDT|650|**D2PR4T1**|
|110/125 Vdc|4PDT|11,000|**D2PR4A1**|
|120 Vac|4PDT|4430|**D2PR4A**|
|220/240 Vac|4PDT|15,720|**D2PR4B**|
|**Latching Style**||||
|24 Vac|DPDT|180|**D2PR5T**|
|24 Vdc|DPDT|650|**D2PR5T1**|
|110 Vac|DPDT|11,000|**D2PR5A**|
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-53**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Accessories**
## **D2PF/D2PR Sockets and Accessories**
|**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**|**Type**|**Module**<br>**Size**<br>**Nominal Voltage**<br>**(Max. for Sockets)**<br>**Nominal**<br>**Current**<br>**Mounting Style**<br>**Wire Size**<br>**Wire**<br>**Connection**<br>**Standard**<br>**Pack**<br>**Catalog**<br>**Number**|
|---|---|---|
||Socket|B<br>300<br>12<br>DIN rail/panel<br>14/16 (2) AWG, 2.5/1.5 (2) mm2<br>Elevator<br>1<br>**D2PAL**1|
|||None<br>300<br>10<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>10<br>**D2PA6**|
|||B<br>300<br>10<br>DIN rail/panel<br>14/16 (2) AWG, 2.5/1.5 (2) mm2<br>Elevator<br>1<br>**D2PAP**1|
|||B<br>300<br>10<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>10<br>**D2PA7**1|
|||None<br>300<br>10<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>5<br>**D2PA4**|
||Flange mount adapter|—<br>—<br>—<br>Flange<br>—<br>—<br>25<br>**PFC-D2D72**|
||Plastic ejector clip|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**PWC-D24**|
||Metal spring clip|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PQC-1782**|
|||—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PQC-1342**|
||Hold-down spring|—<br>—<br>—<br>—<br>—<br>—<br>100<br>**PYC-A1**|
||Protection diode|B<br>6 to 250 Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BD250**|
||LED indicator|B<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BLG24**|
|||B<br>120/240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BLG240**|
||MOV suppressor|B<br>120 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BMV120**|
|||B<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BMV24**|
|||B<br>240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BMV240**|
||Coil bus jumpers|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**D2PJ1**|
||Plastic DIN rail end stop|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PFP-P**|
## _**Note**_
> 1 Protection category (finger safe), EN 60529: IP20.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-54**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
## **Technical Data and Specifications**
|**D2PF/D2PR Relay Specifications**<br>**Description**|**D2PR2/D2PR4**<br>**D2PR5**<br>**D2PF**|
|---|---|
|**Contact Characteristics**||
|Contact rating|10A<br>5A<br>10A|
|Terminal style|Plug-in<br>Plug-in<br>Plug-in|
|Contact materials|Silver alloy<br>Silver (gold flashed)<br>Silver alloy|
|Maximum switching voltage|300V<br>250 Vac/125 Vdc<br>300V|
|Switching current at voltage—resistive|10A at 120 Vac<br>50/60 Hz<br>3A at 250 Vac<br>10A at 277 Vac<br>50/60 Hz||
||8A at 277 Vac<br>50/60 Hz<br>—<br>8A at 120 Vac<br>50/60 Hz|
||8A at 28 Vdc<br>5A at 30 Vdc<br>8A at 28 Vdc|
|Switching current at voltage|1/3 hp at 120 Vac<br>1 hp at 277 Vac<br>1/8 hp at 250 Vac<br>1/3 hp at 120 Vac<br>1 hp at 277 Vac|
|Pilot duty|B300<br>—<br>B300|
|Minimum switching requirement|100 mA at 5 Vdc<br>(0.5W)<br>100 mA, 1 Vdc<br>100 mA at 5 Vdc<br>(0.5W)|
|**Coil Characteristics**||
|Operating range<br>% of nominal (AC)|85 to 110%<br>80 to 110%<br>85 to 110%|
|% of nominal (DC)|80 to 110%<br>80 to 110%<br>80 to 110%|
|Average consumption|1.2 VA<br>—<br>1.2 VA|
||0.9W<br>—<br>0.9W|
|Dropout voltage threshold|15% (AC)<br>30% (AC)<br>15% (AC)|
||10% (DC)<br>10% (DC)<br>10% (DC)|
|**Performance**||
|Electrical life (UL 508) operations at rated current|200,000<br>200,000<br>200,000|
|Mechanical life operations unpowered|10,000,000<br>100,000,000<br>10,000,000|
|Response time|20 ms<br>—<br>20 ms|
|Dielectric strength<br>Between coil and contact Vac (rms)|1500 rms<br>—<br>1500 rms|
|Between poles Vac (rms)|1500 rms<br>—<br>1500 rms|
|**Environment**||
|Ambient air temperature around the device<br>Operation|–40° to 131°F (–40° to 55°C)<br>—<br>–40° to 131°F (–40° to 55°C)|
|Storage|–40° to 185°F (–40° to 85°C)<br>—<br>–40° to 185°F (–40° to 85°C)|
|Vibration resistance—operational|3 g-n at 10–55 Hz<br>—<br>3 g-n at 10–55 Hz|
|Shock resistance|10 g-n<br>—<br>10 g-n|
|Degree of protection|IP40<br>—<br>IP40|
|**Features**||
|Cover options|Plain cover<br>Plain cover<br>Full featured|
|Features|Mechanical flag indicator<br>Latching<br>Locking pushbutton/<br>Bipolar LED/<br>Removable ID tag/<br>Mechanical flag indicator|
|Product certifications|RoHS/UL/CE/CSA<br>UL/CE/CSA<br>RoHS/UL/CE/CSA|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-55**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Wiring Diagrams**
## **D2PF2/D2PR2**
**==> picture [297 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 42 1 4<br>3<br>3 14 44 5 8<br>3<br>3 11 41 9 12<br>3<br>A1 A2 13 14<br>3<br>3 IEC NEMA<br>**----- End of picture text -----**<br>
## **D2PF4/D2PR4**
**==> picture [386 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 22 32 42 1 2 3 4<br>14 24 34 44 5 6 7 8<br>11 21 31 41 9 10 11 12<br>A1 A2 13 14<br>IEC NEMA<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-56**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D2PF2/D2PR2**
**==> picture [464 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.27 0.83 0.83<br>(7.0) 0.02 (21.0) (21.0)<br>(0.5)<br>1.10 1.10<br>(27.9) (27.9)<br>0.24 0.24<br>1.54 (6.0) 1.40 (6.0)<br>(39.1) (35.5)<br>**----- End of picture text -----**<br>
**3**
## **D2PF4/D2PR4**
**==> picture [483 x 409] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.27 0.83 0.83<br>(7.0) 0.02 (21.0) (21.0)<br>(0.5)<br>1.10 1.10<br>(27.9) (27.9)<br>0.24 0.24<br>1.54 (6.0) 1.40 (6.0)<br>(39.1) (35.5)<br>D2PA6<br>0.71<br>(18.0)<br>44 34 24 14 8 7 6 5<br>42 32 22 12 4 3 2 1<br>4 3 2 1 4 3 2 1<br>2.51 N.C. N.C.<br>(64.0) 8 7 6 5 8 7 6 5<br>N.O. N.O.<br>12 11 10 9 12 11 10 9<br>2.71 COM COM<br>(69.0)<br>0.17 14 13 14 13<br>INPUT INPUT<br>(4.3)<br>1.25 Dia.<br>(32.0) 1 1 Typ.<br>4 3<br>A2 INPUT A1 14 INPUT 13<br>1 1 1<br>2 1 0 9<br>41 31 21 11 12 11 10 9<br>1.00 0.89<br>IEC NEMA<br>(25.4) (22.7)<br>1.20<br>(30.7)<br>8 7 6 5<br>4 3 2 1<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-57**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D2PA7**
**3**
**==> picture [499 x 317] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.57<br>1.00<br>(40.0)<br>(25.4)<br>0.74 0.14<br>(19.0) (3.8)<br>34 24<br>7 6 34 24 7 6<br>44 14<br>8 5 44 14 8 5<br>42 32 22 12<br>3.30 42 32 22 12 4 3 2 1<br>(84.0) 4 3 2 1<br>4 3 2 1 4 3 2 1<br>N.C. N.C.<br>(79.0)3.11 (61.0) 2.40 8 7 6 5 N.O. 8 7 6 5 N.O.<br>12 11 10 9 12 11 10 9<br>COM COM<br>0.14 14 13 INPUT 14 13 INPUT<br>(3.80)<br>MODULE MODULE<br>1.55 INPUT INPUT<br>11 (39.5)<br>A2 A1 11 9<br>INPUT INPUT 9 A2 A1 14 13<br>14 13<br>41 31 21 INPUT INPUT<br>41 31 21 12 11 10<br>12 11 10<br>IEC NEMA<br>0.25<br>1.18 0.82<br>(6.4)<br>(30.0) (21.0)<br>1.18<br>(30.0)<br>**----- End of picture text -----**<br>
## **D2PR5**
**==> picture [199 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.10<br>(2.5)<br>14 – 0.05 (1.3) Dia. x 0.09 (2.3)<br>Elliptic Holes<br>0.02<br>(0.5)<br>0.25 1.10<br>(6.4) (27.9)<br>Max.<br>0.02 (0.5) 0.85<br>0.24 (21.6)<br>1.42 (36.1)Max. (6.1) Max.<br>**----- End of picture text -----**<br>
**==> picture [200 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
AC DC<br>1 4 1 4<br>5 8 5 8<br>9 10 11 12 9 10 11 12<br>13 14 13 SET 14<br>RESET R RESET<br>Terminal Arrangement/Internal Connections (Bottom View)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-58**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D2PAP**
**==> picture [500 x 308] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.40<br>(61.0)<br>0.74<br>(19.0)<br>41 31 21 11<br>41 31 21 11 12 11 10 9<br>12 11 10 9<br>44 34 24 14<br>44 34 24 14 8 7 6 5<br>8 7 6 5<br>42 32 22 12 42 32 22 12 4 3 2 1<br>4 3 2 1<br>(85.0)3.34 (5.6)0.20 4 3 2 1 N.C. 4 3 2 1 N.C.<br>8 7 6 5 8 7 6 5<br>N.O. N.O.<br>12 11 10 9 12 11 10 9<br>COM COM<br>3.11<br>(79.0) 14 13 14 13<br>INPUT INPUT<br>1.49 MODULE MODULE<br>(38.0) INPUT INPUT<br>IEC:<br>A2 A1<br>NEMA: A2 INPUT A1 14 INPUT 13<br>14 INPUT 13<br>IEC NEMA<br>0.90<br>(22.0)<br>1.06<br>(26.9)<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-59**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D2PAL**
**==> picture [537 x 476] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.40 1.06<br>3 (61.0) 0.74 (27.0)<br>(19.0)<br>41 11<br>3 41 11 12 9<br>12 9<br>3 44 14 44 14 8 5<br>8 5<br>3 42 12 42 12 4 1<br>3 3.34 0.20 4 1 4 1 4 1<br>(85.0) (5.6) 8 5 N.C. 8 5 N.C.<br>3 N.O. N.O.<br>12 9 12 9<br>COM COM<br>3 3.11<br>(79.0) 14 13 INPUT 14 13 INPUT<br>3<br>3 1.49 MODULEINPUT MODULEINPUT<br>(38.0)<br>3<br>3 A2 IEC:NEMA: A1 A2 INPUT A1 14 INPUT 13<br>14 INPUT 13 IEC NEMA<br>3<br>3 0.92<br>(23.5)<br>3<br>D2PA4 Socket for D2PR5 DPDT Latching Relays Only<br>3<br>Two 0.17 (4.3) x 0.20 (5.1) Terminal Arrangement Mounting Holes<br>3 Mounting Holes (Top View) Two 0.18 (4.6) Dia. or M4<br>(Two 0.16 (4.1) Dia. or M3)<br>3 2 1<br>3<br>8 7 6 5<br>3 2.83 2.320 [+] 0.004<br>(71.9)Max. (58.92–+– 0.10)<br>3<br>12 11 10 9<br>3<br>0.24 (6.1)<br>1.16 0.16 4 14 13<br>(29.5) 0.65 (16.5) 0.870 +– 0.008<br>3 Max. (4.1) (22.09 +– 0.20)<br>1.18<br>3 (30.0) Max.<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-60**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**==> picture [47 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
D3 Series Relay<br>**----- End of picture text -----**<br>
## **Contents**
**==> picture [243 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Page|
|D1PR/D1PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-46|
|D2PR/D2PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-51|
|D3PR/D3PF Series|
|Catalog Number Selection . . . . . . . . . . . . . . . .|V7-T3-62|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-62|
|Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-64|
|Technical Data and Specifications . . . . . . . . . . .|V7-T3-65|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-66|
|D4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-71|
|D5PR/D5PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-75|
|D7PR/D7PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-85|
|D8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-100|
|D9 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-106|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-110|
**----- End of picture text -----**<br>
**3**
## **D3PR/D3PF Series**
## **Product Description**
The D3 Series of relays provides excellent functionality in a popular octal base design. Rigid pins and guide allow for quick and easy installation with little risk of damage.
## **Features**
## _**D3PR**_
- Compact relay capable of breaking relatively large load currents
- Panel and DIN rail mounting
- 8- or 11-pin octal plug-in
## **Standards and Certifications**
## _**D3PF**_
- The contact operation can be easily checked by Pushto-Test button
- (CSA approval not applicable to D3PR5 Relays)
- Flag indicator shows relay status in manual or powered condition
- LED status lamp shows When used with coil ON or OFF status— accompanying Eaton ideal for use in low light **UL Listed** screw terminal socket applications (for D3PF only)
- Push-to-Test button allows for manual operation of relay without the need for coil power
- Lock-down door holds pushbutton and contacts in the operate position when activated
- Finger-grip cover allows operator to remove relays from sockets easily
- ID tag/write label to identify relays in multiplerelay circuits
- Bipolar LED allows for reverse polarity applications
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-61**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Catalog Number Selection**
**==> picture [81 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
D3PR/D3PF Series [1]<br>**----- End of picture text -----**<br>
**==> picture [269 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>D 3 P R 2 1 A<br>3<br>Family Type Coil Voltage<br>3 D3PR = Standard relay A = 120 Vac<br>D3PF = Full featured relay A1 = 110 Vdc<br>B = 240 Vac<br>3 P = 6 Vac<br>Contact Configuration P1 = 6 Vdc<br>3 23 = DPDT (8-pin) = 3PDT (11-pin) R1 R == 12 Vac12 Vdc<br>5 = DPDT latching (11-pin) [2] T = 24 Vac<br>3 T1 = 24 Vdc<br>W = 48 Vac<br>3 Blank = Plain cover relay (D3PR only) Options W1 = 48 Vdc<br>A = LED test button, flag indicator,<br>3 lock-down door, finger-grip cover,<br>ID tag (D3PF only)<br>3 1 = Indicating light (D3PR only)<br>**----- End of picture text -----**<br>
## **Product Selection**
## **D3 Relay/Socket Quick Reference**
|**Relay**<br>**Type**|**Socket**<br>**Clip**<br>**Module**<br>**Type**<br>**ID**<br>**Tag**<br>**Jumper**|
|---|---|
|D3PR2, D3PF2|D3PA6<br>PQC-1332<br>A<br>—<br>D3PJ1|
||D3PAL8<br>PQC-1351<br>A<br>PWF-D3D5<br>—|
||D3PA2<br>PQC-1351<br>None<br>—<br>—|
|D3PR3, D3PF3|D3PA7<br>PQC-1332<br>A<br>—<br>D3PJ1|
||D3PAL11<br>PQC-1351<br>A<br>PWF-D3D5<br>—|
||D3PA3<br>PQC-1351<br>None<br>—<br>—|
|D3PR5|D3PA7<br>PQC-1351<br>A<br>—<br>D3PJ1|
||D3PAL11<br>PQC-1351<br>A<br>PWF-D3D5<br>—|
||D3PA3<br>PQC-1351<br>None<br>—<br>—|
## _**Notes**_
> 1 For deciphering catalog numbers. Do not use for ordering as not all combinations are readily available.
> 2 D3PR only.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-62**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **D3 Series Relay**
## **D3PR/D3PF Series**
||**D3PR/D3PF Series**||||
|---|---|---|---|---|
||**Coil**|**Contact**|**Coil Resistance**|**Catalog**|
||**Voltage**|**Configuration**|**(Ohms)**|**Number**|
|**Full Featured Style**<br>120 Vac<br>~~TO~~||DPDT|1700|**D3PF2AA**|
||240 Vac|DPDT|7200|**D3PF2AB**|
||12 Vdc|DPDT|120|**D3PF2AR1**|
||24 Vdc|DPDT|470|**D3PF2AT1**|
||48 Vdc|DPDT|1800|**D3PF2AW1**|
||120 Vac|3PDT|1700|**D3PF3AA**|
||220/240 Vac|3PDT|7200|**D3PF3AB**|
||6 Vdc|3PDT|32|**D3PF3AP1**|
||24 Vac|3PDT|72|**D3PF3AT**|
||24 Vdc|3PDT|470|**D3PF3AT1**|
||48 Vdc|3PDT|1800|**D3PF3AW1**|
||**Latching Style**||||
||120 Vac|DPDT|10,000|**D3PR5A**|
||110/125 Vdc|DPDT|9000|**D3PR5A1**|
||240 Vac|DPDT|36,000|**D3PR5B**|
||12 Vdc|DPDT|90|**D3PR5R1**|
||24 Vac|DPDT|470|**D3PR5T**|
||24 Vdc|DPDT|350|**D3PR5T1**|
||48 Vdc|DPDT|1400|**D3PR5W1**|
||**Plain Cover with LED Indicator**||||
||120 Vac|DPDT|1700|**D3PR21A**|
||24 Vac|DPDT|72|**D3PR21T**|
||24 Vdc|DPDT|470|**D3PR21T1**|
||220/240 Vac|3PDT|7200|**D3PR31B**|
||24 Vac|3PDT|72|**D3PR31T**|
||24 Vdc|3PDT|470|**D3PR31T1**|
||**Plain Cover Style**||||
||120 Vac|DPDT|1700|**D3PR2A**|
||110/125 Vdc|DPDT|10,000|**D3PR2A1**|
||220/240 Vac|DPDT|7200|**D3PR2B**|
||6 Vac|DPDT|4.2|**D3PR2P**|
||6 Vdc|DPDT|32|**D3PR2P1**|
||12 Vac|DPDT|18|**D3PR2R**|
||12 Vdc|DPDT|120|**D3PR2R1**|
||24 Vac|DPDT|72|**D3PR2T**|
||24 Vdc|DPDT|470|**D3PR2T1**|
||48 Vac|DPDT|290|**D3PR2W**|
||48 Vdc|DPDT|1800|**D3PR2W1**|
||120 Vac|3PDT|1700|**D3PR3A**|
||110/125 Vdc|3PDT|10,000|**D3PR3A1**|
||220/240 Vac|3PDT|7200|**D3PR3B**|
||12 Vac|3PDT|18|**D3PR3R**|
||12 Vdc|3PDT|120|**D3PR3R1**|
||24 Vac|3PDT|72|**D3PR3T**|
||24 Vdc|3PDT|470|**D3PR3T1**|
||48 Vdc|3PDT|1800|**D3PR3W1**|
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-63**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Accessories**
## **D3PR/D3PF Series Sockets and Accessories**
|**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**<br>**3**|**Type**|**Module**<br>**Size**<br>**Nominal Voltage**<br>**(Max. for Sockets)**<br>**Nominal**<br>**Current**<br>**Mounting Style**<br>**Wire Size**<br>**Wire**<br>**Connection**<br>**Standard**<br>**Pack**<br>**Catalog**<br>**Number**|
|---|---|---|
||Socket|A<br>300<br>16<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>1<br>**D3PA6**1|
|||A<br>300<br>12<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Elevator<br>10<br>**D3PAL8**1|
|||None<br>300/600<br>15/10<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>10<br>**D3PA2**|
|||A<br>600<br>5<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>1<br>**D3PA7**1|
|||A<br>300<br>12<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Elevator<br>10<br>**D3PAL11**1|
|||None<br>300/600<br>15/5<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>10<br>**D3PA3**|
||Metal spring clip|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PQC-1332**|
|||—<br>—<br>—<br>—<br>—<br>—<br>10<br>**PQC-1351**|
||Protection diode|A<br>6 to 250 Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AD250**|
||LED indicator|A<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-ALG24**|
|||A<br>120/240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-ALG240**|
||MOV suppressor|A<br>120 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AMV120**|
|||A<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AMV24**|
|||A<br>240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AMV240**|
||R/C suppressor|A<br>6 to 24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-RC24**|
|||A<br>110 to 240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-RC240**|
||Write-on plastic labels|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**PWF-D3D5**|
||Coil bus jumpers|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**D3PJ1**|
||Plastic DIN rail end stop|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PFP-P**|
||||
## _**Note**_
> 1 Protection category (finger safe), EN 60529: IP20.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-64**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Technical Data and Specifications**
## **D3PR/D3PF Series Relay Specifications**
|**Description**|**D3PR**<br>**D3PF**<br>**D3PR5**<br>**(Latching)**|
|---|---|
|**Contact Characteristics**||
|Contact rating|16A<br>16A<br>16A|
|Terminal style|Octal<br>Octal<br>11-pin octal|
|Contact materials|Silver alloy<br>Silver alloy<br>Silver alloy|
|Maximum switching voltage|300V<br>300V<br>300V|
|Switching current at voltage—resistive|16A at 277 Vac<br>50/60 Hz<br>16A at 277 Vac<br>50/60 Hz<br>16A at 277 Vac<br>50/60 Hz|
||16A at 120 Vac<br>50/60 Hz<br>16A at 120 Vac<br>50/60 Hz<br>—|
||16A at 28 Vdc<br>16A at 28 Vdc<br>16A at 28 Vdc|
|Switching current at voltage|1/2 hp at 240 Vac<br>1/2 hp at 240 Vac<br>1/2 hp at 240 Vac|
||1/3 hp at 120 Vac<br>1/3 hp at 120 Vac<br>1/3 hp at 120 Vac|
|Pilot duty|B300<br>B300<br>B300|
|Minimum switching requirement|100 mA at 5 Vdc<br>(0.5W)<br>100 mA at 5 Vdc<br>(0.5W)<br>100 mA at 5 Vdc<br>(0.5W)|
|**Coil Characteristics**||
|Operating range<br>% of nominal (AC)|85 to 110%<br>85 to 110%<br>85 to 110%|
|% of nominal (DC)|80 to 110%<br>80 to 110%<br>80 to 110%|
|Average consumption|3 VA<br>3 VA<br>2 VA|
||1.4W<br>1.4W<br>1.64W|
|Dropout voltage threshold|15% (AC)<br>15% (AC)<br>15% (AC)|
||10% (DC)<br>10% (DC)<br>10% (DC)|
|**Performance**||
|Electrical life (UL 508) operations at rated current|100,000 operations<br>100,000 operations<br>100,000 operations|
|Mechanical life operations unpowered|5,000,000 operations<br>5,000,000 operations<br>10,000,000 operations|
|Response time|20 ms<br>20 ms<br>30 ms|
|Dielectric strength<br>Between coil and contact Vac (rms)|1500V (rms)<br>1500V (rms)<br>2500V (rms)|
|Between poles Vac (rms)|1500V (rms)<br>1500V (rms)<br>1500V (rms)|
|**Environment**||
|Ambient air temperature around the device<br>Storage<br>Operation|–40° to 185°F (–40° to 85°C)<br>–40° to 185°F (–40° to 85°C)<br>–40° to 185°F (–40° to 85°C)|
||–40° to 131°F (–40° to 55°C)<br>–40° to 131°F (–40° to 55°C)<br>–40° to 131°F (–40° to 55°C)|
|Vibration resistance—operational|3 g-n at 10–55 Hz<br>3 g-n at 10–55 Hz<br>3 g-n at 10–55 Hz|
|Shock resistance|10 g-n<br>10 g-n<br>10 g-n|
|Degree of protection|IP40<br>IP40<br>IP40|
|**Features**||
|Cover options|Plain cover<br>Full Featured<br>Latching|
|Features|Mechanical flag indicator<br>Bipolar LED/<br>Locking pushbutton/<br>Removable ID tag/<br>Mechanical flag indicator<br>—|
|Product certifications|RoHS/UL/CE/CSA<br>RoHS/UL/CE/CSA<br>RoHS/UL/UR|
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-65**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D3PR2/D3PF2**
**==> picture [37 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>**----- End of picture text -----**<br>
**==> picture [501 x 197] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.39 1.39<br>(35.3) (35.3)<br>0.24 1.37 1.37<br>(6.1) 2.20 (34.8) 2.10 (34.8)<br>(55.2) (50.3)<br>12 22 4 5<br>14 24 3 6<br>A1 A2 2 7<br>11 31 1 8<br>IEC NEMA<br>**----- End of picture text -----**<br>
## **D3PR3/D3PF3**
**==> picture [503 x 211] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.39 1.39<br>(35.3) (35.3)<br>0.24<br>(6.1) 2.20 (34.8)1.37 2.10 (34.8)1.37<br>(55.2) (50.3)<br>21 6<br>22 24 5 7<br>12 32 4 8<br>14 34 3 9<br>A1 A2 2 10<br>11 31 1 11<br>IEC NEMA<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-66**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D3PR5—Octal Base Latching Relay**
**==> picture [481 x 451] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.39<br>(35.3)<br>2.40 1.37<br>(61.0) (34.8)<br>RESET RESET RESET RESET<br>COIL 2 COIL 2<br>21 21 6 6<br>22 24 22 24 5 7 5 7<br>12 32 12 32 4 8 4 8<br>14 34 14 34 3 9 3 9<br>A1 A2 A1 A2 2 10 2 10<br>COMMON 11 31 11 31 COMMON 1 11 NEMA 1 11<br>IEC<br>COIL 1 COIL 1<br>SET SET SET SET<br>Single Co( liAC) Dua lCo( liDC) Single Co( liAC) Dua lCo( liDC)<br>D3PA2<br>0.97<br>1.60<br>(24.6)<br>(40.0)<br>0.59 1.29<br>(15.0) (33.0)<br>A1 11 21 A2 2 1 8 7<br>2.02 0.16 INPUT 1 8 INPUT INPUT 1 8 INPUT<br>(4.2)<br>(51.0)<br>2 7 2 7<br>2.12 3 6 3 6<br>(54.0)<br>4 5 4 5<br>1.01 3 5 6 4<br>(25.6) 14 12 22 24 3 4 5 6<br>IEC NEMA<br>2 1 8 7<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-67**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D3PA3**
**==> picture [539 x 399] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.32<br>3 0.97 (59.0)<br>(24.6)<br>3 (52.0)2.06<br>3<br>3 11 31 1 11<br>A1 A2 2 10<br>1 11 14 34 3 9<br>3 1.60 Dia.(40.0) 2 10 2.05 INPUT2 11 INPUT10 INPUT2 11 INPUT10<br>3 43 98 (52.0)<br>2.16<br>(54.8)<br>3 1.02 12 32 4 8<br>(25.0) 5 7<br>6 22 24 5 7<br>3 21 6<br>3 IEC NEMA<br>3<br>0.97<br>1.60<br>(24.6)<br>3 (40.0)<br>0.59 1.29<br>3 (15.0) (33.0)<br>3<br>A1 11 21 A2 2 1 8 7<br>3 2.02 0.16 INPUT 1 8 INPUT INPUT 1 8 INPUT<br>(4.2)<br>(51.0)<br>3 2 7 2 7<br>2.12 3 6 3 6<br>3 (54.0)<br>4 5 4 5<br>3 1.01 3 4 5 6<br>(25.6) 14 12 22 24 3 4 5 6<br>3 IEC NEMA<br>1 1<br>3 9 3 9<br>4 8 4 8<br>5 6 7 5 6 7<br>2 1 8 7<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-68**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D3PA6**
**==> picture [486 x 255] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.45<br>(37.0)<br>1.42<br>1.10 (36.0)<br>(27.9)<br>22 11 12 22 11 12 5 1 4<br>5 1 4<br>24 21 14 24 21 14 6 8 3<br>6 8 3<br>2.86<br>(72.0) 0.15<br>3.00 (3.8) 5 4 5 4<br>(76.0)<br>6 3 6 3<br>7 2 7 2<br>8 1 8 1<br>1.58 MODULE MODULE<br>(40.0) INPUT INPUT<br>IEC:<br>NEMA:<br>A2 A1 Coil Jumper Buss 7 Coil Jumper Buss 2<br>INPUT INPUT<br>7<br>IEC NEMA<br>1.20<br>(30.0)<br>INPUT INPUT<br>A2 A1<br>2<br>**----- End of picture text -----**<br>
**3**
**==> picture [485 x 284] intentionally omitted <==**
**----- Start of picture text -----**<br>
D3PA7<br>1.45<br>(37.0)<br>1.10 1.50<br>(27.9) (38.0)<br>32 24 22 12<br>8 7 5 4<br>31 21 11<br>11 6 1<br>(81.0)3.18 34 14 (3.8)0.15<br>9 3<br>3.01<br>(76.0)<br>MODULE MODULE<br>INPUT INPUT<br>1.58<br>(40.0)<br>Coil Jumper Buss 10 Coil Jumper Buss 2<br>IEC:<br>NEMA: INPUT INPUT<br>A2 A1 IEC NEMA<br>10<br>1.35<br>(34.2)<br>INPUT INPUT<br>32 24 22 12<br>31 21 11 11<br>34 14<br>A2 A1<br>10 2 10 2<br>11 11<br>2<br>6 6<br>7 5 7 5<br>8 4 8 4<br>9 3 9 3<br>1 1<br>8 7 5 4<br>6 1<br>9 3<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-69**
3.4
## Control Relays and Timers
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D3PAL8**
**==> picture [525 x 540] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.86<br>(22.0)<br>3 24 22 12 14<br>24 22 12 14 6 5 4 3<br>4 3 —_—— OCOOC0C 6 5 4 3 A0C0C00 O0COO0<br>3<br>3 0.12<br>(3.10)<br>2.95<br>| O90 ore ole<br>3 (75.0) ‘he O O O O O O<br>3<br>| es OO mon o e)r non o e)r<br>3 1.45<br>3 (37.0) INPUT A27 INPUT A1IEC: 2 MODULEINPUT MODULEINPUT<br>NEMA:<br>O a O YO i<br>3 A2 A2 21 11 A1 A2 A2 21 11 A1 7 7 8 1 2<br>DOQOOA! CO CCO O C OCO0OO<br>7 7 8 1 2<br>3 0.12 INPUT INPUT INPUT INPUT<br>1.06 (30.0) IEC NEMA<br>(27.0)<br>3 1.49<br>— fT (38.0) 7<br>3<br>D3PAL11<br>3<br>0.86<br>(22.0)<br>3 —- —<br>34 32 24 22 14 12<br>34 32 24 22 14 12 9 8 7 5 3 4<br>3 OOOCOCOG COCOCOCO OOOOCOO<br>9 8 7 5 3 4<br>3<br>3 0.12 7 6 5 7 6 5<br>(3.1)<br>3 2.95 | ee Oo” 8 O 4 4 O 8 oneneO 4<br>(75.0)<br>3 9 3 9 3<br>10 2 10 2<br>3 5 9 ° unre 11 1 ure 11 1<br>1.45 INPUT A2 INPUT A1<br>3 (37.0) MODULE MODULE<br>0 10 L IEC:NEMA: d 2 O INPUT YO INPUT Y<br>3 A2 A2 31 21 11 A1<br>A2 A2 31 21 11 A1 10 10 11 6 1 2<br>OOOCOCDO) O O OCCO C O OCCOO<br>3 10 10 11 6 1 2 INPUT INPUT INPUT INPUT<br>0.12<br>3 1.06 (30.0) IEC NEMA<br>(27.0)<br>1.49<br>(38.0)<br>5 4 5 4<br>6 3 6 3<br>7 2 7 2<br>8 1 8 1<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-70**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **D4 Series Relay**
## **Contents**
|**Contents**||**3**|
|---|---|---|
|**_Description_**|**_Page_**||
|D1PR/D1PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-46**|**3**|
|D2PR/D2PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-51**||
|D3PR/D3PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-61**|**3**|
|D4 Series<br>Technical Data and Specifications . . . . . . . . . . .|**V7-T3-73**|**3**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>D5PR/D5PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-74**<br>**V7-T3-75**|**3**|
|D7PR/D7PF Series . . . . . . . . . . . . . . . . . . . . . . . . .<br>D8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-85**<br>**V7-T3-100**|**3**|
|D9 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-106**<br>**V7-T3-110**|**3**|
## **D4 Series**
## **Product Description**
The D4 Series is a slim-form relay designed to fit into tight spaces. The retaining clip is built in to the socket to provide easy and secure assembly.
## **Features**
- Slim-styled power relay
- Socket has built-in holddown clip
- Panel or DIN rail mounting
## **Standards and Certifications**
File # E1491, E65657 File # LR701519
## **Catalog Number Selection**
**D4 Series**[1]
|**D4 Series**[1]|**D4 Series**[1]|**D4 Series**[1]|**D4 Series**[1]|**D4 Series**[1]|**D4 Series**[1]|**D4 Series**[1]|**D4 Series**[1]|||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|**D 4 P R**<br>**1**<br>**Family Type**<br>**D4PR**<br>~~LO~~<br>~~——~~||||||||**1**||**A**<br>**Coil Voltage**<br> **A**= 120 Vac<br>**A1**= 110 Vdc||
|**Contact Configuration**|||||||||||**B**= 240 Vac<br>**P**= 6 Vac|
|**1**= SPDT<br>**2**= DPDT|||||||||||**P1**= 6 Vdc<br>**R**= 12 Vac|
||||||||||||**R1**= 12 Vdc|
|**Options**|||||||||||**T**= 24 Vac<br>**T1**= 24 Vdc|
|**Blank**= Plain cover|||||||||||**W**= 48 Vac|
|**1**=Indicating light|||||||||||**W1**= 48 Vdc|
## **Product Selection**
## **D4 Relay/Socket Quick Reference**
|**Relay Type**|**Socket**|**Hold-Down Clip**|
|---|---|---|
|D4PR1|D4PA1|2|
|D4PR2|D4PA2|2|
## _**Notes**_
- 1 For deciphering catalog numbers. Do not use for ordering as not all combinations are readily available.
- 2 Socket has built-in hold-down spring.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-71**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
## **D4 Series Relay**
## **D4 Series**
|**D4 Series**||||||
|---|---|---|---|---|---|
||**Standard**|**Catalog**||**Standard**|**Catalog**|
|**Voltage/Poles**<br>**DIN Rail Sockets**|**Pack**|**Number**|**Voltage/Poles**<br>**DPDT with Indicating Light**|**Pack**<br>**DPDT with Indicating Light**|**Number**|
|Single-pole|10|**D4PA1**|120 Vac|1|**D4PR21A**|
|Two-pole|10|**D4PA2**|110 Vdc|1|**D4PR21A1**|
|**SPDT with Indicating Light**|**SPDT with Indicating Light**||240 Vac|1|**D4PR21B**|
|120 Vac|1|**D4PR11A**|6 Vac|50|**D4PR21P**|
|110 Vdc|1|**D4PR11A1**|6 Vdc|1|**D4PR21P1**|
|240 Vac|1|**D4PR11B**|12 Vac|50|**D4PR21R**|
|6 Vac|50|**D4PR11P**|12 Vdc|1|**D4PR21R1**|
|6 Vdc|50|**D4PR11P1**|24 Vac|1|**D4PR21T**|
|12 Vac|50|**D4PR11R**|24 Vdc|1|**D4PR21T1**|
|12 Vdc|1|**D4PR11R1**|48 Vdc|50|**D4PR21W1**|
|24 Vac<br>24 Vdc|1<br>1|**D4PR11T**<br>**D4PR11T1**|**Standard DPDT**<br>120 Vac|1|**D4PR2A**|
|48 Vdc|50|**D4PR11W1**|110 Vdc|50|**D4PR2A1**|
|**Standard SPDT**|||240 Vac|50|**D4PR2B**|
|120 Vac|1|**D4PR1A**|6 Vac|50|**D4PR2P**|
|110 Vdc|50|**D4PR1A1**|6 Vdc|1|**D4PR2P1**|
|240 Vac|50|**D4PR1P**|12 Vac|50|**D4PR2R**|
|6 Vac<br>6 Vdc|1<br>50|**D4PR1P1**<br>**D4PR1R**|12 Vdc<br>24 Vac|1<br>1|**D4PR2R1**<br>**D4PR2T**|
|12 Vac|1|**D4PR1R1**|24 Vdc|1|**D4PR2T1**|
|12 Vdc|1|**D4PR1R1-A2**|48 Vdc|1|**D4PR2W1**|
|24 Vac|1|**D4PR1T**||||
|24 Vdc|1|**D4PR1T1**||||
|48 Vdc|1|**D4PR1W1**||||
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-72**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Technical Data and Specifications**
|**D4 Series**<br>**Description**|**Resistive Load**<br>**(p.f. = 1)**<br>**Inductive Load**<br>**(p.f. = 0.4, L/R = 7 ms)**|
|---|---|
|**D4PR1**||
|Rated load|250 Vac 10A<br>250 Vac 7.5A|
||30 Vdc 10A<br>30 Vdc 5A|
|Carry current|10A<br>10A|
|Max. operating voltage|380 Vac/125 Vdc<br>380 Vac/125 Vdc|
|Max. operating current|10A<br>10A|
|Contact material|AgCdO<br>AgCdO|
|Max. switching capacity|2500 VA<br>1875 VA|
||300W<br>150W|
|Min. permissible load|100 mA, 5 Vdc<br>100 mA, 5 Vdc|
|Pickup voltage (max.)|80% AC/70% DC<br>80% AC/70% DC|
|Dropout voltage (min.)|30% AC/15% DC<br>30% AC/15% DC|
|Voltage (max.)|110%<br>110%|
|Mechanical life (min.)|10,000,000 AC/20,000,000 DC<br>10,000,000 AC/20,000,000 DC|
|Electrical life at all contact ratings (min.)|100,000<br>100,000|
|Maximum hp ratings|1/3 hp (125 Vac)<br>1/3 hp (125 Vac)|
||1/2 hp (250 Vac)<br>1/2 hp (250 Vac)|
||1/2 hp (277 Vac)<br>1/2 hp (277 Vac)|
|**D4PR2**||
|Rated load|240 Vac 5A<br>250 Vac 2A|
||30 Vdc 5A<br>30 Vdc 3A|
|Carry current|5A<br>5A|
|Max. operating voltage|380 Vac/125 Vdc<br>380 Vac/125 Vdc|
|Max. operating current|5A<br>5A|
|Contact material|AgCdO<br>AgCdO|
|Max. switching capacity|1250 VA<br>500 VA|
||150W<br>90W|
|Min. permissible load|10 mA, 5 Vdc<br>10 mA, 5 Vdc|
|Pickup voltage (max.)|80% AC/70% DC<br>80% AC/70% DC|
|Dropout voltage (min.)|30% AC/15% DC<br>30% AC/15% DC|
|Voltage (max.)|110%<br>110%|
|Mechanical life (min.)|10,000,000 AC/20,000,000 DC<br>10,000,000 AC/20,000,000 DC|
|Electrical life at all contact ratings (min.)|100,000<br>100,000|
|Maximum hp ratings|1/6 hp (120 Vac)<br>1/6 hp (120 Vac)|
||1/3 hp (240 Vac)<br>1/3 hp (240 Vac)|
||1/3 hp (265 Vac)<br>1/3 hp (265 Vac)|
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-73**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
**D4PR1**
## **D4PR2**
**==> picture [473 x 166] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.51 0.51<br>3 (2.5)0.10 (29.0)Max.1.14 (13.0)Max. (10.0)0.39 (2.5)0.01 (29.0)Max.1.14 (13.0)Max. (10.0)0.39<br>0.08<br>3 (2.0)<br>1.14 1.10<br>(29.0) (28.0)<br>3 (20.0)0.79 Max. Max. (20.0)0.79 [0.08]<br>(2.0)<br>0.02<br>3 (4.8)0.19 (0.5)0.02(0.5) (4.0)0.16 (6.0)0.24 (2.6)0.10 (0.5)0.02 (4.0)0.16<br>3 5 – 0.035 x 0.12(0.9 x 3)<br>Elliptic Holes 0.35 0.30<br>0.30 (8.9) (7.5)<br>(7.5) 1 2 3 4<br>3 (5.2)0.20 (5.2)0.20 1 2 4 3 (0.5)0.020.76 (0.5)0.02 8 7 6 5<br>3 (17.5)0.69 Terminal Arrangement/ 5 (19.4) Terminal Arrangement/Internal Connections<br>Internal Connections (Bottom View)<br>(Bottom View)<br>3<br>**----- End of picture text -----**<br>
## **D4PA1**
**==> picture [383 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.28(7.1) (2.0)0.08 Dia. Holes(4.1)0.16<br>3.5 x 0.32Five Dia. Holes0.17 (4.2)<br>2.82 (88.9 x 8.0) 4<br>(71.6)Max. (35.6)1.40 3 1.180 0.002<br>(29.97 0.05)<br>2 M3 or<br>0.16 0.77 0.77 (19.6)1.18 (30.0) 5 1 3.30 (0.13)Dia. Holes<br>(4.1) (19.6)<br>Max. 2.13 (54.1) Max.<br>Terminal Arrangement Mounting Holes<br>**----- End of picture text -----**<br>
## **D4PA2**
**==> picture [383 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.28(7.1) (2.0)0.08 Dia. Holes(4.1)0.16<br>0.17 (4.2)<br>3.5 x 0.32Eight Dia. Holes<br>2.82 (88.9 x 8.0) 6 3<br>(71.6)Max. (35.6)1.40 5 4 1.180 0.002<br>(29.97 0.05)<br>7 2 M3 or<br>0.77 (19.6) 8 1 0.13 (3.30)<br>0.16 0.77 1.18 (30.0) Dia. Holes<br>(4.1) (19.6)<br>Max. 2.13 (54.1) Max.<br>Terminal Arrangement Mounting Holes<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-74**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**D5 Series Relay**
## **Contents**
**==> picture [278 x 181] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Description|Page|
|D1PR/D1PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-46|3|
|D2PR/D2PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-51|
|D3PR/D3PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-61|3|
|D4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-71|
|D5PR/D5PF Series|3|
|Catalog Number Selection . . . . . . . . . . . . . . . .|V7-T3-76|
|3|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-76|
|Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-79|
|3|
|Technical Data and Specifications . . . . . . . . . . .|V7-T3-80|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-81|3|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-82|
|D7PR/D7PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-85|3|
|D8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-100|
|D9 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-106|3|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-110|
**----- End of picture text -----**<br>
## **D5PR/D5PF Series**
## **Product Description**
The D5 Series is rated at 16A and is available in fullfeatured and plain cover styles.
## **Features**
## _**D5PR**_
- Industrial rated 300V, 16A relay in two-pole and threepole configurations
- Compact design can be panel or DIN rail mounted
## **Standards and Certifications**
## _**D5PF**_
- Flag indicator shows relay status in manual or powered condition
- When used with
- powered condition
- ● LED status lamp shows **UL Listed** accompanying Eaton screw terminal socket coil ON or OFF status— (D5PF only)
- ideal for use in low light applications
- Push-to-Test button allows for manual operation of relay without the need for coil power
- Lock-down door holds pushbutton and contacts in the operate position when activated
- Finger-grip cover allows operator to remove relays from sockets easily
- ID tag/write label to identify relays in multiplerelay circuits
- Bipolar LED allows for reverse polarity applications
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-75**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Catalog Number Selection**
## **D5 Series**
**==> picture [349 x 163] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>D 5 P R 3 1 A<br>3<br>Family Type Coil Voltage<br>3 D5PR = Standard relay A = 120 Vac<br>D5PF = Full featured relay A1 = 110 Vdc<br>B = 240 Vac<br>3 G1 = 74 Vdc<br>Contact Configuration P = 6 Vac<br>3 23 = DPDT = 3PDT P1 R == 6 Vdc12 Vac<br>R1 = 12 Vdc<br>3 Blank A == LED test button, flag indicator, Plain cover (D5PR only) Options T1 W T === 24 Vac24 Vdc48 Vac<br>3 lock-down door, finger-grip cover, W1 = 48 Vdc<br>ID tag (D5PF only)<br>3 1 = Indicating light (D5PR only)<br>**----- End of picture text -----**<br>
## **Product Selection**
## **D5 Relay/Socket Quick Reference**
|**Relay**<br>**Type**|**Socket**<br>**Clip**<br>**Module**<br>**Type**<br>**ID**<br>**Tag**<br>**Jumper**|
|---|---|
|D5PR2, D5PF2,<br>D5PR3, D5PF3|D5PAL<br>PQC-1351<br>A<br>PWF-D3D5<br>D3PJ1|
||D5PA2<br>PQC-1351<br>None<br>—<br>—|
||D5PA3L<br>PQC-1351<br>None<br>—<br>—|
||D5PA3S<br>PQC-1351<br>None<br>—<br>—|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-76**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **D5 Series**
|||||**D5 Series**||||
|---|---|---|---|---|---|---|---|
|**D5 Series Relay**|**D5 Series Relay**|**D5 Series Relay**||**D5 Series**||||
|||||**Coil**|**Contact**|**Coil Resistance**|**Catalog**|
||=~|_|s=-|**Voltage**|**Configuration**|**(Ohms)**|**Number**|
|||||**Full Featured**||||
|||||120 Vac|DPDT|1700|**D5PF2AA**|
|||||110/125 Vdc|DPDT|10,000|**D5PF2AA1**|
|||||220/240 Vac|DPDT|7200|**D5PF2AB**|
|||||12 Vdc|DPDT|120|**D5PF2AR1**|
|||||24 Vac|DPDT|72|**D5PF2AT**|
|||||24 Vdc|DPDT|470|**D5PF2AT1**|
|||||48 Vdc|DPDT|1800|**D5PF2AW1**|
|||||120 Vac|3PDT|1700|**D5PF3AA**|
|||||110/125 Vdc|3PDT|10,000|**D5PF3AA1**|
|||||220/240 Vac|3PDT|7200|**D5PF3AB**|
|||||12 Vdc|3PDT|120|**D5PF3AR1**|
|||||24 Vac|3PDT|72|**D5PF3AT**|
|||||24 Vdc|3PDT|470|**D5PF3AT1**|
|||||**Plain Cover with LED**||||
|||||110/125 Vdc|DPDT|10,000|**D5PR21A1**|
|||||6 Vac|DPDT|4.2|**D5PR21P**|
|||||6 Vdc|DPDT|32|**D5PR21P1**|
|||||12 Vac|DPDT|18|**D5PR21R**|
|||||12 Vdc|DPDT|120|**D5PR21R1**|
|||||24 Vdc|DPDT|470|**D5PR21T1**|
|||||48 Vac|DPDT|290|**D5PR21W**|
|||||48 Vdc|DPDT|1800|**D5PR21W1**|
|||||120 Vac|3PDT|1700|**D5PR31A**|
|||||110/125 Vdc|3PDT|10,000|**D5PR31A1**|
|||||6 Vdc|3PDT|32|**D5PR31P1**|
|||||12 Vac|3PDT|18|**D5PR31R**|
|||||12 Vdc|3PDT|120|**D5PR31R1**|
|||||24 Vdc|3PDT|470|**D5PR31T1**|
|||||48 Vdc|3PDT|1800|**D5PR31W1**|
|||||**Side Flange Cover**||||
|||||220/240 Vac|DPDT|7200|**D5PR24B**|
|||||6 Vac|DPDT|4.2|**D5PR24P**|
|||||6 Vdc|DPDT|32|**D5PR24P1**|
|||||12 Vac|DPDT|18|**D5PR24R**|
|||||12 Vdc|DPDT|120|**D5PR24R1**|
|||||24 Vac|DPDT|72|**D5PR24T**|
|||||24 Vdc|DPDT|470|**D5PR24T1**|
|||||48 Vac|DPDT|290|**D5PR24W**|
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-77**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
## **D5 Series Relay**
## **D5 Series, continued**
|**Coil**|**Contact**|**Coil Resistance**|**Catalog**|
|---|---|---|---|
|**Voltage**<br>**Plain Cover**|**Configuration**|**(Ohms)**|**Number**|
|120 Vac|DPDT|1700|**D5PR2A**|
|110/125 Vdc|DPDT|10,000|**D5PR2A1**|
|220/240 Vac|DPDT|7200|**D5PR2B**|
|74 Vdc|DPDT|4800|**D5PR2G1**|
|6 Vac|DPDT|4.2|**D5PR2P**|
|6 Vdc|DPDT|32|**D5PR2P1**|
|12 Vac|DPDT|18|**D5PR2R**|
|12 Vdc|DPDT|120|**D5PR2R1**|
|24 Vac|DPDT|72|**D5PR2T**|
|24 Vdc|DPDT|470|**D5PR2T1**|
|48 Vac<br>48 Vdc|DPDT<br>DPDT|290<br>1800|**D5PR2W**<br>**D5PR2W1**|
|120 Vac|3PDT|1700|**D5PR3A**|
|110/125 Vdc|3PDT|10,000|**D5PR3A1**|
|220/240 Vac|3PDT|7200|**D5PR3B**|
|74 Vdc|3PDT|4800|**D5PR3G1**|
|6 Vac|3PDT|4.2|**D5PR3P**|
|6 Vdc<br>12 Vac|3PDT<br>3PDT|32<br>18|**D5PR3P1**<br>**D5PR3R**|
|12 Vdc|3PDT|120|**D5PR3R1**|
|24 Vac|3PDT|72|**D5PR3T**|
|24 Vdc|3PDT|470|**D5PR3T1**|
|48 Vdc|3PDT|1800|**D5PR3W**|
|48 Vdc|3PDT|1800|**D5PR3W1**|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-78**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Accessories**
## **D5 Sockets and Accessories**
|**Type**|**Module**<br>**Size**<br>**Nominal Voltage**<br>**(Max. for Sockets)**<br>**Nominal**<br>**Current**<br>**Mounting Style**<br>**Wire Size**<br>**Wire**<br>**Connection**<br>**Standard**<br>**Pack**<br>**Catalog**<br>**Number**|
|---|---|
|Socket|A<br>300<br>25<br>DIN rail<br>10 /14 (2) AWG, 6/2.5 (2) mm2<br>Elevator<br>10<br>**D5PAL**1|
||None<br>300<br>15<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>10<br>**D5PA2**|
||None<br>300<br>15<br>Chassis<br>(Output): 16 AWG, 1 mm2<br>Solder<br>10<br>**D5PA3L**|
||None<br>300<br>15<br>Chassis<br>(Output): 16 AWG, 1 mm2<br>Solder<br>10<br>**D5PA3S**|
|Metal spring clip|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**PQC-1351**|
|Protection diode|A<br>6 to 250 Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AD250**|
|LED indicator|A<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-ALG24**|
||A<br>120/240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-ALG240**|
|MOV suppressor|A<br>120 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AMV120**|
||A<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AMV24**|
||A<br>240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AMV240**|
|R/C suppressor|A<br>6 to 24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-RC24**|
||A<br>110 to 240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-RC240**|
|Write-on plastic labels|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**PWF-D3D5**|
|Coil bus jumpers|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**D3PJ1**|
|Plastic DIN rail end stop|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PFP-P**|
**3**
## _**Note**_
> 1 Protection category (finger safe), EN 60529: IP20.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-79**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
## **Technical Data and Specifications**
|**D5 Series**<br>**Description**|**D5PR**<br>**D5PF**|
|---|---|
|**Contact Characteristics**||
|Contact rating|16A<br>16A|
|Terminal style|Plug-in<br>Plug-in|
|Contact materials|Silver alloy<br>Silver alloy|
|Maximum switching voltage|300V<br>300V|
|Switching current at voltage—resistive|16A at 277 Vac 50/60 Hz<br>16A at 277 Vac 50/60 Hz|
||16A at 120 Vac 50/60 Hz<br>16A at 120 Vac 50/60 Hz|
||16A at 28 Vdc<br>16A at 28 Vdc|
|Switching current at voltage|1/2 hp at 240 Vac<br>1/2 hp at 240 Vac|
||1/3 hp at 120 Vac<br>1/3 hp at 120 Vac|
|Pilot duty|B300<br>B300|
|Minimum switching requirement|100 mA at 5 Vdc (0.5W)<br>100 mA at 5 Vdc (0.5W)|
|**Coil Characteristics**||
|Operating range<br>% of nominal (AC)|85 to 110%<br>85 to 110%|
|% of nominal (DC)|80 to 110%<br>80 to 110%|
|Average consumption|3 VA<br>1.4W<br>3 VA<br>1.4W|
|Drop-out voltage threshold|10%/15% (AC)<br>10% (DC)<br>10%/15% (AC)<br>10% (DC)|
|**Performance**||
|Electrical life (UL 508) operations at rated current|100,000 operations<br>100,000 operations|
|Mechanical life operations unpowered|5,000,000 operations<br>5,000,000 operations|
|Response time|20 ms<br>20 ms|
|Dielectric strength<br>Between coil and contact Vac (rms)|1500V (rms)<br>1500V (rms)|
|Between poles Vac (rms)|1500V (rms)<br>1500V (rms)|
|**Environment**||
|Ambient air temperature around the device<br>Storage|–40° to 185°F (–40° to 85°C)<br>–40° to 185°F (–40° to 85°C)|
|Operation|–40° to 131°F (–40° to 55°C)<br>–40° to 131°F (–40° to 55°C)|
|Vibration resistance—operational|3 g-n at 10–55 Hz<br>3 g-n at 10–55 Hz|
|Shock resistance|10 g-n<br>10 g-n|
|Degree of protection|IP40<br>IP40|
|**Features**||
|Cover options|Flange/plain cover with LED<br>Full featured|
|Features|Mechanical flag indicator<br>(LED optional)<br>Bipolar LED/<br>Mechanical flag indicator/<br>Locking pushbutton/<br>Removable ID tag|
|Product certifications|RoHS/UL/CE/CSA<br>RoHS/UL/CE/CSA|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-80**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Wiring Diagrams**
## **D5PA3L and D5PA3S**
**==> picture [396 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 32 22 1 2 3<br>N.C. N.C.<br>14 34 24 4 5 6<br>N.O. N.O.<br>11 31 21 7 8 9<br>COM COM<br>A1 A2 A B<br>INPUT INPUT<br>IEC NEMA<br>**----- End of picture text -----**<br>
**3**
## **D5PR2/D5PF2 DPDT**
**==> picture [315 x 163] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 22 1 3<br>14 24 4 6<br>11 21 7 9<br>A1 A2 A B<br>IEC NEMA<br>**----- End of picture text -----**<br>
## **D5PR3/D5PF3 3PDT**
**==> picture [387 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 32 22 1 2 3<br>14 34 24 4 5 6<br>11 31 21 7 8 9<br>A1 A2 A B<br>IEC NEMA<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-81**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D5PR and D5PF**
**3**
**==> picture [472 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.40 1.40<br>(35.4) (35.4)<br>0.20<br>(6.1) 2.10 (34.9)1.37 (50.0)1.97 (34.9)1.37<br>(53.1)<br>**----- End of picture text -----**<br>
## **D5PA2**
**==> picture [483 x 246] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.69<br>(43.0)<br>1.03 1.53<br>(26.0) (39.0)<br>0.40 1.37<br>(10.0) (35.0)<br>24 34 14 6 5 4<br>22 32 12 3 2 1<br>0.15<br>(3.8) 3 2 1 3 2 1<br>N.C. N.C.<br>3.00 6 5 4 6 5 4<br>N.O. N.O.<br>(76.0)<br>3.14 9 8 7 COM 9 8 7 COM<br>(80.0)<br>B A B A<br>INPUT INPUT<br>B A<br>1.50<br>(38.0) A2 A1 B A<br>INPUT INPUT<br>21 31 11 9 8 7<br>9 8 7<br>IEC NEMA<br>6 5 4<br>3 2 1<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-82**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D5PA3L and D5PA3S**
**==> picture [466 x 406] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.30 1.50 0.87<br>(7.5) (38.1) (22.2)<br>0.02<br>(0.5)<br>1 2 3<br>2.03<br>(51.0) 1.37<br>(34.7) 4 5 6<br>7 8 9<br>1.25<br>(31.7) 1.68<br>(42.8)<br>A B<br>0.16 Dia.<br>(4.2)<br>0.50 2 Holes<br>0.29 (2.5) Recommended<br>Chassis Cutout 0.16 (3.9)<br>(7.5) 0.87 Dia. Holes<br>(22.2)<br>0.28<br>(5.3)<br>0.63<br>(16.2)<br>1.68<br>(42.6)<br>0.13<br>0.24 1.37 (3.3)<br>(6.1) 1.27<br>(34.7)<br>(32.3)<br>Solder Type Terminals<br>0.29<br>(7.5)<br>0.63<br>(16.2) 1.39<br>(35.4)<br>0.18<br>(4.7)<br>0.24 1.37 Typ.<br>(6.1) (34.7)<br>3/16 Q.C. Type Terminals 0.19 (4.7)<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-83**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D5PAL**
**3**
**==> picture [477 x 239] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.48<br>(63.0)<br>21 31 11<br>9 8 7 21 31 11 9 8 7<br>24 34 14<br>6 5 4 24 34 14 6 5 4<br>22 32 12<br>3 2 1 22 32 12 3 2 1<br>3.70<br>(96.0)<br>N.C. N.C.<br>3.62 3 6 2 5 1 4 N.O. 3 6 2 5 1 4 N.O.<br>(92.0) 9 8 7 9 8 7<br>COM COM<br>B A B A<br>INPUT INPUT<br>MODULE MODULE<br>INPUT INPUT<br>A27 IEC:NEMA: A12 A2 Coil JumperBuss A1 B Coil JumperBuss A<br>INPUT<br>INPUT INPUT INPUT INPUT<br>1.40 IEC NEMA<br>(36.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-84**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **D7 Series Relay**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D1PR/D1PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-46**|
|D2PR/D2PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-51**|
|D3PR/D3PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-61**|
|D4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>D5PR/D5PF Series . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-71**<br>**V7-T3-75**|
|D7PR/D7PF Series<br>Catalog Number Selection . . . . . . . . . . . . . . . .|**V7-T3-86**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .<br>Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-86**<br>**V7-T3-89**|
|Technical Data and Specifications . . . . . . . . . . .<br>Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-90**<br>**V7-T3-92**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-93**|
|D8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-100**|
|D9 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-106**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-110**|
**3**
## **D7PR/D7PF Series**
## **Product Description**
The D7 Series is a costeffective control relay with high dielectric strength and high current-carrying capacity.
## **Features**
## _**D7PR**_
- Arc barrier equipped relay with high dielectric strength
- Panel and DIN rail mounting
## _**D7PF**_
- Flag indicator shows relay status in manual or powered condition
- Bipolar LED status lamp allows for reverse polarity applications
## **Standards and Certifications**
File # E37317, E65657 File # LR217017, LR217069
- Shows coil ON or OFF status
- Ideal in low light conditions
- Color-coded pushbutton identifies AC coils with red or DC coils with blue pushbuttons
- Allows for manual operation of relay without the need for coil power
- Ideal for field service personnel to test control circuits
- Lock-down door, when activated, holds pushbutton and contacts in the operate position
- Excellent for analyzing circuit problems
- Finger-grip cover allows operator to remove relays from sockets more easily than conventional relays
- White plastic ID tag/write label used for identification of relays in multi-relay circuits
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-85**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Catalog Number Selection**
## **D7 Series**
**==> picture [273 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>D 7 P R 1 1 A<br>3<br>Family Type Coil Voltage<br>3 D7PRD7PF = Full featured relay = Standard relay A1 A == 120 Vac110 Vdc<br>B = 240 Vac<br>3 P = 6 Vac<br>Contact Configuration P1 = 6 Vdc<br>1 = SPDT 3 = 3PDT R = 12 Vac<br>3 2 = DPDT 4 = 4PDT R1 = 12 Vdc<br>T = 24 Vac<br>3 Options T1 W == 48 Vac24 Vdc<br>Blank = Plain cover (D7PR only) W1 = 48 Vdc<br>3 A = LED test button, flag indicator,<br>lock-down door, finger-grip cover,<br>3 1 = Indicating light (D7PR only)ID tag (D7PF only)<br>**----- End of picture text -----**<br>
## **Product Selection**
## **D7 Relay/Socket Quick Reference**
|**Relay**<br>**Type**|**Socket/Adapter**|**Clip**<br>**Module**<br>**Type**<br>**ID Tag**<br>**Jumper**|
|---|---|---|
|D7PR1, D7PR2,<br>D7PF1, D7PF2|D7PAA|PQC-1342<br>B<br>—<br>—|
|||PQC-1349<br>B<br>—<br>—|
||D7PA9|PQC-1342<br>None<br>—<br>—|
||PFC-D2D72|—<br>None<br>—<br>—|
|D7PR3, D7PF3|D7PAB|PQC-1783<br>A<br>—<br>—|
|||PMC-1783<br>A<br>—<br>—|
||PFC-D73|—<br>None<br>—<br>—|
|D7PR4, D7PF4|D7PAD|PQC-1784<br>A<br>—<br>—|
|||PMC-1784<br>A<br>—<br>—|
||PFC-D74|—<br>None<br>—<br>—|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-86**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **D7 Series**
**==> picture [375 x 500] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|D7 Series Relay|
|Coil|Contact|Coil Resistance|Catalog|
|Voltage|Configuration|(Ohms)|Number|
|Full Featured|
|120 Vac|SPDT|4430|D7PF1AA|
|—:|i|a|
|6 Vac|SPDT|9.6|D7PF1AP|
|6 Vdc|SPDT|40|D7PF1AP1|
|HO|
|=|=|—.|
|12 Vac|SPDT|46|D7PF1AR|
|24 Vdc|SPDT|650|D7PF1AT1|
|48 Vac|SPDT|788|D7PF1AW|
|48 Vdc|SPDT|2600|D7PF1AW1|
|120 Vac|DPDT|4430|D7PF2AA|
|110/125 Vdc|DPDT|11,000|D7PF2AA1|
|220/240 Vac|DPDT|15,720|D7PF2AB|
|6 Vac|DPDT|9.6|D7PF2AP|
|6 Vdc|DPDT|40|D7PF2AP1|
|12 Vac|DPDT|46|D7PF2AR|
|12 Vdc|DPDT|160|D7PF2AR1|
|24 Vac|DPDT|180|D7PF2AT|
|24 Vdc|DPDT|650|D7PF2AT1|
|48 Vac|DPDT|788|D7PF2AW|
|48 Vdc|DPDT|2600|D7PF2AW1|
|120 Vac|3PDT|2770|D7PF3AA|
|6 Vac|3PDT|6|D7PF3AP|
|6 Vdc|3PDT|25|D7PF3AP1|
|12 Vac|3PDT|25.3|D7PF3AR|
|24 Vac|3PDT|103|D7PF3AT|
|24 Vdc|3PDT|400|D7PF3AT1|
|48 Vac|3PDT|412|D7PF3AW|
|48 Vdc|3PDT|1600|D7PF3AW1|
|120 Vac|4PDT|2220|D7PF4AA|
|110/125 Vdc|4PDT|7340|D7PF4AA1|
|240 Vac|4PDT|9120|D7PF4AB|
|6 Vac|4PDT|5.4|D7PF4AP|
|6 Vdc|4PDT|24|D7PF4AP1|
|12 Vac|4PDT|21.2|D7PF4AR|
|12 Vdc|4PDT|96|D7PF4AR1|
|24 Vac|4PDT|84.5|D7PF4AT|
|24 Vdc|4PDT|388|D7PF4AT1|
|48 Vdc|4PDT|1550|D7PF4AW|
|48 Vac|4PDT|410|D7PF4AW1|
**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-87**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **D7 Series Relay**
## **D7 Series, continued**
|**3**|**D7 Series Relay**|**D7 Series, continued**|**D7 Series, continued**|||
|---|---|---|---|---|---|
|**3**||**Coil**|**Contact**|**Coil Resistance**|**Catalog**|
|**3**|LN|**Voltage**<br>**Configuration**<br>**(Ohms)**<br>**Number**<br>**Plain Cover with LED**<br> ~~SS~~||||
||u<br>“|~~ee~~||||
|**3**<br>**3**|=‘i|120 Vac<br>SPDT<br>4430<br>**D7PR11A**<br>110/125 Vdc<br>SPDT<br>11,000<br>**D7PR11A1**<br>6 Vac<br>SPDT<br>9.6<br>**D7PR11P**<br>12 Vac<br>SPDT<br>46<br>**D7PR11R**<br> ~~ae~~||||
|**3**||12 Vdc|SPDT|160|**D7PR11R1**|
|||24 Vac|SPDT|180|**D7PR11T**|
|**3**||24 Vdc|SPDT|650|**D7PR11T1**|
|||48 Vdc|SPDT|2600|**D7PR11W1**|
|**3**||120 Vac|3PDT|2770|**D7PR31A**|
|||240 Vac|3PDT|12100|**D7PR31B**|
|**3**||24 Vac|3PDT|103|**D7PR31T**|
|**3**||24 Vdc<br>48 Vdc|3PDT<br>3PDT|400<br>1600|**D7PR31T1**<br>**D7PR31W1**|
|**3**||120 Vac<br>12 Vdc|4PDT<br>4PDT|2220<br>100|**D7PR41A**<br>**D7PR41R1**|
|**3**||24 Vdc|4PDT|388|**D7PR41T1**|
|||**Plain Cover**||||
|**3**||120 Vac|SPDT|4430|**D7PR1A**|
|||110/125 Vdc|SPDT|11000|**D7PR1A1**|
|**3**||220/240 Vac|SPDT|15720|**D7PR1B**|
|||6 Vac|SPDT|9.6|**D7PR1P**|
|**3**||12 Vdc|SPDT|160|**D7PR1R1**|
|||24 Vac|SPDT|180|**D7PR1T**|
|**3**||24 Vdc|SPDT|650|**D7PR1T1**|
|**3**||48 Vdc<br>120 Vac|SPDT<br>DPDT|2600<br>4430|**D7PR1W1**<br>**D7PR2A**|
|**3**||110/125 Vdc<br>220/240 Vac|DPDT<br>DPDT|11000<br>15720|**D7PR2A1**<br>**D7PR2B**|
|**3**||6 Vac|DPDT|9.6|**D7PR2P**|
|||6 Vdc|DPDT|40|**D7PR2P1**|
|**3**||12 Vac|DPDT|46|**D7PR2R**|
|||12 Vdc|DPDT|160|**D7PR2R1**|
|**3**||24 Vac|DPDT|180|**D7PR2T**|
|||24 Vdc|DPDT|650|**D7PR2T1**|
|**3**||120 Vac|3PDT|2770|**D7PR3A**|
|||240 Vac|3PDT|12100|**D7PR3B**|
|**3**||6 Vac|3PDT|6|**D7PR3P**|
|**3**||12 Vac<br>12 Vdc|3PDT<br>3PDT|25.3<br>100|**D7PR3R**<br>**D7PR3R1**|
|**3**||24 Vac<br>24 Vdc|3PDT<br>3PDT|103<br>400|**D7PR3T**<br>**D7PR3T1**|
|**3**||48 Vdc<br>120 Vac|3PDT<br>4PDT|1600<br>2220|**D7PR3W1**<br>**D7PR4A**|
|**3**||110/125 Vdc|4PDT|7340|**D7PR4A1**|
|||240 Vac|4PDT|9120|**D7PR4B**|
|**3**||6 Vac|4PDT|5.4|**D7PR4P**|
|||24 Vac|4PDT|84.5|**D7PR4T**|
|**3**||24 Vdc|4PDT|388|**D7PR4T1**|
|||48 Vdc|4PDT|1550|**D7PR4W1**|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-88**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Accessories**
## **D7 Sockets and Accessories**
|**Type**|**Module**<br>**Size**<br>**Nominal Voltage**<br>**(Max. for Sockets)**<br>**Nominal**<br>**Current**<br>**Mounting Style**<br>**Wire Size**<br>**Wire**<br>**Connection**<br>**Standard**<br>**Pack**<br>**Catalog**<br>**Number**|
|---|---|
|Socket|B<br>300<br>16<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>—<br>**D7PAA**1|
||None<br>300<br>10<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>1<br>**D7PA9**|
||A<br>300<br>16<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>—<br>**D7PAD**1|
||A<br>300<br>16<br>DIN rail/panel<br>12/14 (2) AWG, 4/2.5 (2) mm2<br>Screw clamping<br>—<br>**D7PAB**1|
|Flange mount adapter|—<br>—<br>—<br>Flange<br>—<br>—<br>25<br>**PFC-D2D72**|
||—<br>—<br>—<br>Flange<br>—<br>—<br>25<br>**PFC-D73**|
||—<br>—<br>—<br>Flange<br>—<br>—<br>25<br>**PFC-D74**|
|Metal spring clip|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PQC-1342**|
|Plastic ID clip|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**PQC-1349**|
|Metal spring clip|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PQC-1784**|
|Plastic ID clip|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**PMC-1784**|
|Hold-down spring|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PYC-B2**|
|Metal spring clip|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**PQC-1783**|
|Plastic ID clip|—<br>—<br>—<br>—<br>—<br>—<br>10<br>**PMC-1783**|
|Protection diode|A<br>6 to 250 Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AD250**|
|LED indicator|A<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-ALG24**|
||A<br>120/240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-ALG240**|
|MOV suppressor|A<br>120 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AMV120**|
||A<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AMV24**|
||A<br>240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-AMV240**|
|R/C suppressor|A<br>6 to 24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-RC24**|
||A<br>110 to 240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-RC240**|
|Protection diode|B<br>6 to 250 Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BD250**|
|LED indicator|B<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BLG24**|
||B<br>120/240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BLG240**|
|MOV suppressor|B<br>120 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BMV120**|
||B<br>24 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BMV24**|
||B<br>240 Vac/Vdc<br>—<br>—<br>—<br>—<br>20<br>**MOD-BMV240**|
|Plastic DIN rail end stop|—<br>—<br>—<br>—<br>—<br>—<br>25<br>**PFP-P**|
**3**
## _**Note**_
> 1 Protection category (finger safe), EN 60529: IP20.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-89**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Technical Data and Specifications**
**3**
|**D7PR Relay**<br>**Description**|**D7PR (SPDT)**<br>**D7PR (DPDT)**<br>**D7PR (3PDT)**<br>**D7PR (4PDT)**|
|---|---|
|**Contact Characteristics**||
|Contact rating|20A<br>15A<br>15A<br>15A|
|Terminal style|Plug-in<br>Plug-in<br>Plug-in<br>Plug-in|
|Contact materials|Silver alloy<br>Silver alloy<br>Silver alloy<br>Silver alloy|
|Maximum switching voltage|300V<br>300V<br>300V<br>300V|
|Switching current at voltage—resistive|20A at 277 Vac 50/60 Hz<br>15A at 120 Vac 50/60 Hz<br>15A at 120 Vac 50/60 Hz<br>15A at 120 Vac 50/60 Hz|
||20A at 120 Vac 50/60 Hz<br>12A at 277 Vac 50/60 Hz<br>12A at 277 Vac 50/60 Hz<br>12A at 277 Vac 50/60 Hz|
||—<br>10A at 277 Vac 50/60 Hz<br>—<br>—|
||20A at 28 Vdc<br>12A at 28 Vdc<br>12A at 28 Vdc<br>12A at 28 Vdc|
|Switching current at voltage|1/2 hp at 120 Vac<br>1/2 hp at 120 Vac<br>1/2 hp at 120 Vac<br>1/2 hp at 120 Vac|
||1 hp at 250 Vac<br>1 hp at 250 Vac<br>3/4 hp at 250 Vac<br>3/4 hp at 250 Vac|
|Pilot duty|B300<br>B300<br>B300<br>B300|
|Minimum switching requirement|100 mA at 5 Vdc (0.5W)<br>100 mA at 5 Vdc (0.5W)<br>100 mA at 5 Vdc (0.5W)<br>100 mA at 5 Vdc (0.5W)|
|**Coil Characteristics**||
|Operating range<br>% of nominal (AC)|85 to 110%<br>85 to 110%<br>85 to 110%<br>85 to 110%|
|% of nominal (DC)|80 to 110%<br>80 to 110%<br>80 to 110%<br>80 to 110%|
|Average consumption|1.2 VA<br>1.2 VA<br>1.5 VA<br>1.5 VA|
||0.9W<br>0.9W<br>1.4W<br>1.5W|
|Dropout voltage threshold|15% (AC)<br>15% (AC)<br>15% (AC)<br>15% (AC)|
||10% (DC)<br>10% (DC)<br>10% (DC)<br>10% (DC)|
|**Performance**||
|Electrical life (UL 508) operations at rated current|100,000 operations<br>100,000 operations<br>200,000 operations<br>200,000 operations|
|Mechanical life operations unpowered|10,000,000 operations<br>10,000,000 operations<br>10,000,000 operations<br>10,000,000 operations|
|Response time|20 ms<br>20 ms<br>20 ms<br>20 ms|
|Dielectric strength<br>Between coil and contact Vac (rms)|2500V (rms)<br>2500V (rms)<br>2500V (rms)<br>2500V (rms)|
|Between poles Vac (rms)|1500V (rms)<br>1500V (rms)<br>2500V (rms)<br>2500V (rms)|
|**Environment**||
|Ambient air temperature around the device<br>Operation|–40° to 131°F (–40° to 55°C)<br>–40° to 131°F (–40° to 55°C)<br>–40° to 131°F (–40° to 55°C)<br>–40° to 131°F (–40° to 55°C)|
|Storage|–40° to 185°F (–40° to 85°C)<br>–40° to 185°F (–40° to 85°C)<br>–40° to 185°F (–40° to 85°C)<br>–40° to 185°F (–40° to 85°C)|
|Vibration resistance—operational|3 g-n at 10–55 Hz<br>3 g-n at 10–55 Hz<br>3 g-n at 10–55 Hz<br>3 g-n at 10–55 Hz|
|Shock resistance|10 g-n<br>10 g-n<br>10 g-n<br>10 g-n|
|Degree of protection|IP40<br>IP40<br>IP40<br>IP40|
|**Features**||
|Cover options|Plain cover<br>Plain cover<br>Plain cover<br>Plain cover|
|Features|Mechanical flag indicator<br>(optional LED)<br>Mechanical flag indicator<br>(optional LED)<br>Mechanical flag indicator<br>(optional LED)<br>Mechanical flag indicator<br>(optional LED)|
|Product certifications|RoHS/UL/CE/CSA<br>RoHS/UL/CE/CSA<br>RoHS/UL/CE/CSA<br>RoHS/UL/CE/CSA|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-90**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
## **D7PF Relay**
|**D7PF Relay**||
|---|---|
|**Description**|**D7PF (SPDT)**<br>**D7PF (DPDT)**<br>**D7PF (3PDT)**<br>**D7PF (4PDT)**|
|**Contact Characteristics**||
|Contact rating|20A<br>15A<br>15A<br>15A|
|Terminal style|Plug-in<br>Plug-in<br>Plug-in<br>Plug-in|
|Contact materials|Silver alloy<br>Silver alloy<br>Silver alloy<br>Silver alloy|
|Maximum switching voltage|300V<br>300V<br>300V<br>300V|
|Switching current at voltage—resistive|20A at 277 Vac 50/60 Hz<br>15A at 120 Vac 50/60 Hz<br>15A at 120 Vac 50/60 Hz<br>15A at 120 Vac 50/60 Hz|
||20A at 277 Vac 50/60 Hz<br>12A at 277 Vac 50/60 Hz<br>12A at 277 Vac 50/60 Hz<br>12A at 277 Vac 50/60 Hz|
||—<br>10A at 277 Vac 50/60 Hz<br>—<br>—|
||20A at 28 Vdc<br>12A at 28 VDC<br>12A at 28 Vdc<br>12A at 28 Vdc|
|Switching current at voltage|1/2 hp at 120 Vac<br>1/2 hp at 120 Vac<br>3/4 hp at 250 Vac<br>1/2 hp at 120 Vac|
||1 hp at 250 Vac<br>1 hp at 250 Vac<br>1/2 hp at 120 Vac<br>3/4 hp at 250 Vac|
|Pilot duty|B300<br>B300<br>B300<br>B300|
|Minimum switching requirement|100 mA at 5 Vdc (0.5W)<br>100 mA at 5 Vdc (0.5W)<br>100 mA at 5 Vdc (0.5W)<br>100 mA at 5 Vdc (0.5W)|
|**Coil Characteristics**||
|Operating range<br>% of nominal (AC)|85 to 110%<br>85 to 110%<br>85 to 110%<br>85 to 110%|
|% of nominal (DC)|80 to 110%<br>80 to 110%<br>80 to 110%<br>80 to 110%|
|Average consumption|1.2 VA<br>1.2 VA<br>1.5 VA<br>1.5 VA|
||0.9W<br>0.9W<br>1.4W<br>1.5W|
|Dropout voltage threshold|15% (AC)<br>15% (AC)<br>15% (AC)<br>15% (AC)|
||10% (DC)<br>10% (DC)<br>10% (DC)<br>10% (DC)|
|**Performance**||
|Electrical life (UL 508) operations at rated current|100,000 operations<br>100,000 operations<br>200,000 operations<br>200,000 operations|
|Mechanical life operations unpowered|10,000,000 operations<br>10,000,000 operations<br>10,000,000 operations<br>10,000,000 operations|
|Response time|20 ms<br>20 ms<br>20 ms<br>20 ms|
|Dielectric strength<br>Between coil and contact Vac (rms)|2500V (rms)<br>2500V (rms)<br>2500V (rms)<br>2500V (rms)|
|Between poles Vac (rms)|1500V (rms)<br>1500V (rms)<br>2500V (rms)<br>2500V (rms)|
|**Environment**||
|Ambient air temperature around the device<br>Operation|–40° to 131°F (–40° to 55°C)<br>–40° to 131°F (–40° to 55°C)<br>–40° to 131ºF (–40° to 55°C)<br>–40° to 131°F (–40° to 55°C)|
|Storage|–40° to 185°F (–40° to 85°C)<br>–40° to 185°F (–40° to 85°C)<br>–40° to 185ºF (–40° to 85°C)<br>–40° to 185°F (–40° to 85°C)|
|Vibration resistance—operational|3 g-n at 10–55 Hz<br>3 g-n at 10–55 Hz<br>3 g-n at 10–55 Hz<br>3 g-n at 10–55 Hz|
|Shock resistance|10 g-n<br>10 g-n<br>10 g-n<br>10 g-n|
|Degree of protection|IP40<br>IP40<br>IP40<br>IP40|
|**Features**||
|Cover options|Full featured<br>Full featured<br>Full featured<br>Full featured|
|Features|Locking pushbutton/<br>Bipolar LED/<br>Removable ID tag/<br>Mechanical flag indicator<br>Locking pushbutton/<br>Bipolar LED/<br>Removable ID tag/<br>Mechanical flag indicator<br>Locking pushbutton/<br>Bipolar LED/<br>Removable ID tag/<br>Mechanical flag indicator<br>Locking pushbutton/<br>Bipolar LED/<br>Removable ID tag/<br>Mechanical flag indicator|
|Product certifications|RoHS/UL/CE/CSA<br>RoHS/UL/CE/CSA<br>RoHS/UL/CE/CSA<br>RoHS/UL/CE/CSA|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-91**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Wiring Diagrams**
## **D7PR1/D7PF1**
**==> picture [317 x 284] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 42 1 4<br>3<br>3 14 44 5 8<br>3<br>11 41 9 12<br>3<br>3 A1 A2 13 14<br>3<br>IEC NEMA<br>3<br>D7PR2/D7PF2<br>3 12 42 1 4<br>3 14 44 5 8<br>3<br>3 11 41 9 12<br>3 A1 A2 13 14<br>3<br>IEC NEMA<br>**----- End of picture text -----**<br>
## **D7PR3/D7PF3**
**==> picture [366 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 22 42 1 2 4<br>14 24 44 5 6 8<br>11 21 41 9 10 12<br>A1 A2 13 14<br>IEC NEMA<br>**----- End of picture text -----**<br>
## **D7PR4/D7PF4**
**==> picture [434 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
12 22 32 42 1 2 3 4<br>14 24 34 44 5 6 7 8<br>11 21 31 41 9 10 11 12<br>A1 A2 13 14<br>IEC NEMA<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-92**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D7PR1/D7PF1**
**==> picture [457 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.27 0.29 0.83 0.29 0.83<br>(7.0) (7.4) (21.0) (7.4) (21.0)<br>0.02 0.02<br>(0.5) (0.5)<br>1.10 1.10<br>(27.9) (27.9)<br>(39.1)1.54 (4.8)0.19 (35.5)1.40 (4.8)0.19<br>0.38 0.16<br>(9.9) (4.7)<br>0.23<br>(5.9)<br>0.30<br>(7.5)<br>0.08<br>(2.1)2X 0.55<br>(14.1)<br>**----- End of picture text -----**<br>
**3**
## **D7PR2/D7PF2**
**==> picture [457 x 219] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.27 0.29 0.83 0.29 0.83<br>(7.0) (7.4) (21.0) (7.4) (21.0)<br>0.02 0.02<br>(0.5) (0.5)<br>1.10 1.10<br>(27.9) (27.9)<br>(39.1)1.54 (4.8)0.19 (35.5)1.40 (4.8)0.19<br>0.38 0.16<br>(9.9) (4.7)<br>0.23<br>(5.9)<br>0.30<br>(7.5)<br>0.08<br>(2.1)2X 0.55<br>(14.1)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-93**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D7PR3/D7PF3**
**==> picture [531 x 249] intentionally omitted <==**
**----- Start of picture text -----**<br>
33 0.27(7.0) (6.6)0.26 0.02 (30.8)1.20 0.29(7.4) 0.02 (30.8)1.20<br>(0.5) (0.5)<br>3<br>1.10 1.10<br>(27.9) (27.9)<br>3<br>3 1.60 (4.8)0.19 1.40 0.19<br>(40.0) (35.5) (4.8)<br>3<br>0.39<br>3 0.39 (9.9) (4.7)0.19<br>(9.9) 0.23<br>3 (5.9)<br>0.26<br>(6.7)<br>3<br>3<br>0.39<br>3 (9.9)2X<br>0.79<br>3 (20.0)<br>**----- End of picture text -----**<br>
## **D7PR4/D7PF4**
**==> picture [499 x 239] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.27 0.26 1.60 0.29 1.60<br>(7.0) (6.6) (40.6) (7.4) (40.6)<br>0.02 0.02<br>(0.5) (0.5)<br>1.10 1.10<br>(27.9) (27.9)<br>1.54 0.19 1.40 0.19<br>(39.1) (4.8) (35.5) (4.8)<br>0.38<br>0.38 (9.9)<br>0.38 (9.9) 0.16<br>(4.7)<br>(9.9)<br>0.23<br>(5.9)<br>0.26<br>(6.7)<br>0.38<br>(9.9)2X<br>1.18<br>(29.9)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-94**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D7PA3**
**==> picture [227 x 204] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 10<br>4 7<br>5 8<br>2<br>6 9<br>3 11<br>Wiring Diagram (Top View)<br>2.74 (69.8)<br>2.58 (67.5) Max.<br>1.09<br>(27.8)<br>Max.<br>0.65<br>(16.6)<br>Combination Slotted/Phillips<br>Head Screws 6-32 x 5/16"<br>**----- End of picture text -----**<br>
**==> picture [231 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 1 10 7<br>1.44<br>(36.6) 5 2 8 (40.5)1.59<br>1.27 Max.<br>(32.5) 3<br>6 11 9<br>**----- End of picture text -----**<br>
## **D7PA4**
**==> picture [176 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 13<br>5 9<br>2<br>6 10<br>11<br>7<br>3<br>8 12<br>4 14<br>Wiring Diagram (Top View)<br>**----- End of picture text -----**<br>
**==> picture [228 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.74 (69.8)<br>2.58 (67.5) Max.<br>1.09<br>(27.8)<br>Max.<br>0.65<br>(16.6)<br>Combination Slotted/Phillips<br>Head Screws 6-32 x 5/16"<br>**----- End of picture text -----**<br>
**==> picture [231 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
5 1 13 9<br>1.83 6 2 10<br>(46.5) 1.98<br>(50.5)<br>1.63 Max.<br>(41.4) 7 3 11<br>8 4 14 12<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-95**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D7PA9 Standard Mount**
**==> picture [514 x 314] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 0.71<br>(18.0)<br>3<br>3 44 14 8 5<br>3<br>3<br>2.52 N.C. N.C.<br>3 (64.0) 8 5 8 5<br>N.O. N.O.<br>3 2.73 12 9 COM 12 9 COM<br>(69.0)<br>3 0.16<br>(4.0) 14 13 INPUT 14 13 INPUT<br>3<br>1.26<br>(32.0)<br>3 A2 A1 INPUT 14 13 INPUT<br>14 13<br>3<br>41 11 12 9<br>3 12 9<br>IEC NEMA<br>3 1.02 1.03<br>(26.0) (26.0)<br>3<br>1.17<br>3 (29.0)<br>1 1<br>42 4<br>4 4<br>12 1<br>8 5<br>4 1<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-96**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D7PAA**
**==> picture [495 x 350] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.18<br>(30.0)<br>0.74<br>(19.0)<br>44 14<br>44 14 8 5<br>8 5<br>42 12 42 12 4 1<br>4 1<br>4 1 4 1<br>3.14 N.C. N.C.<br>0.16 (80.0) 8 5 N.O. 8 5 N.O.<br>(4.0) 12 9 12 9<br>COM COM<br>3.33 14 13 INPUT 14 13 INPUT<br>2.67<br>(84.0)<br>(68.0)<br>MODULE MODULE<br>INPUT INPUT<br>1.57 IEC: A2 A1 INPUT 14 13 INPUT<br>INPUT NEMA: INPUT<br>(40.0)<br>A2 A1 0.24<br>14 13 (6.0) 41 11 12 9<br>41 11<br>IEC NEMA<br>12 9<br>1.06<br>(26.0)<br>1.18<br>(30.0)<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-97**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D7PAB**
**==> picture [546 x 314] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 1.18<br>(30.0) 1.10<br>3 0.74 (28.0)<br>(19.0)<br>3 44 24 14<br>3 8 6 5 44 24 14 8 6 5<br>42 22 12<br>42 22 12 4 2 1<br>3 4 2 1<br>4 2 1 4 2 1<br>N.C. N.C.<br>3 3.14 8 6 5 N.O. 8 6 5 N.O.<br>(80.0)<br>0.16 12 10 9 12 10 9<br>3 (4.0) COM COM<br>14 13 INPUT 14 13 INPUT<br>3<br>2.67<br>3.33<br>(68.0) MODULE MODULE<br>3 (84.0) INPUT INPUT<br>IEC:<br>NEMA:<br>3 1.57 INPUT INPUT A2 INPUT A1 14 INPUT 13<br>(40.0)<br>A2 A1 0.24<br>3 41 21 11 12 10 9<br>(6.0)<br>14 13<br>3 41 21 11 IEC NEMA<br>3 12 10 9<br>3 1.45<br>(37.0)<br>1.57<br>3 (40.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-98**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D7PAD**
**==> picture [549 x 350] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.18 44 34 24 14<br>(30.0)<br>0.74 (36.0)1.41 42 32 22 12 3<br>(19.0)<br>4 3 2 1 N.C. 3<br>44 34 24 14 8 7 6 5 N.O.<br>8 7 6 5 12 11 10 9 COM 3<br>42 32 22 12 INPUT 3<br>4 3 2 1<br>MODULE<br>INPUT 3<br>0.16 A2 A1 3<br>(4.0) INPUT<br>3.33<br>(84.0) 2.67 41 31 21 11 3<br>(68.0)<br>IEC<br>3<br>3.14<br>(80.0) 8 7 6 5<br>IEC:<br>NEMA: 3<br>(40.0)1.57 INPUTA214 INPUTA113 4 4 3 3 2 2 1 1N.C. 3<br>8 7 6 5 N.O. 3<br>41 31 21 11 12 11 10 9 COM<br>12 11 10 9 INPUT 3<br>MODULE 3<br>1.81 0.24 INPUT<br>(46.0) (6.0)<br>1.96 3<br>(50.0) 14 INPUT 13<br>3<br>12 11 10 9<br>NEMA 3<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-99**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
**==> picture [45 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
D8 Series Relay<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D1PR/D1PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-46**|
|D2PR/D2PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-51**|
|D3PR/D3PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-61**|
|D4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-71**|
|D5PR/D5PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-75**|
|D7PR/D7PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-85**|
|D8 Series||
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V7-T3-101**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-101**|
|Technical Data and Specifications . . . . . . . . . . .|**V7-T3-102**|
|Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-103**|
|D9 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-106**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-110**|
## **D8 Series**
## **Product Description**
The D8 Series power relays are perfect for loads up to 30A, with versions for flange mounting and e-clip mounting available.
## **Features**
- Allows switching of 25A and 30A loads
- A high-capacity, highwithstand voltage relay compatible with momentary voltage drops
## **Standards and Certifications**
File # E1491
File # LR701520
- No contact chattering for momentary voltage drops up to 50% of rated voltage
- UL Class B construction standard
- Wide-range AC-activated coil that handles 100 to 120 Vac at either 50 or 60 Hz
- Panel, DIN rail and flange mounting
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-100**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Catalog Number Selection**
**D8 Series**[1]
**==> picture [226 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
D 8 P R 6 T E A<br>Family Type Coil Voltage<br>== D8PR A = 120 Vac<br>|| 8 B = 240 Vac<br>R1 = 12 Vdc<br>Contact Configuration T = 24 Vac<br>6 = SPST-NO T1 = 24 Vdc<br>7 = DPST-NO<br>Options<br>TE = E-bracket<br>=| TF = Flange mount<br>Product Selection<br>**----- End of picture text -----**<br>
**3**
## **D8 Relay/Socket Quick Reference**
||||**Front Connecting**|
|---|---|---|---|
|**Relay**|**Mounting**|**Adapter Track/**|**Sockets Track/**|
|**Type**|**Bracket**|**Panel Mount**|**Panel Mount**|
|D8PR6TE|D8PA5|D8PA1|D8PA2|
|D8PR7TE|D8PA5|D8PA1|D8PA2|
**D8 Series**[2] **D8 Series Relay Type SPST E-Bracket** Coil voltage 24 Vac =.
|**D8 Series**[2]|||
|---|---|---|
|**Type**<br>**SPST E-Bracket**<br>Coil voltage<br>24 Vac|**Standard**<br>**Pack**<br>1|**Catalog**<br>**Number**<br>**D8PR6TET**|
|24 Vdc|1|**D8PR6TET1**|
|**SPST Flange Mount**|||
|120 Vac|1|**D8PR6TFA**|
|24 Vdc|1|**D8PR6TFT1**|
|**DPST E-Bracket**|||
|Coil voltage|||
|120 Vac|1|**D8PR7TEA**|
|**DPST Flange Mount**|||
|120 Vac|1|**D8PR7TFA**|
|24 Vdc|1|**D8PR7TFT1**|
|**Sockets**|||
|DIN rail adapter|10|**D8PA1**|
|Screw terminal adapter|10|**D8PA2**|
|Bracket adapter|10|**D8PA5**|
|**Accessory**|||
|DIN rail end stop|100|**PFP-M**|
## _**Notes**_
1 For deciphering catalog numbers. Do not use for ordering as not all combinations are readily available.
2 Additional coil voltages available—consult Sales Office or Customer Support Center.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-101**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Technical Data and Specifications**
## **Coil Resistance**
**3**
|**Coil Resistance**|||
|---|---|---|
|**Coil Voltage**|**Ohms**|**mA**|
|24 Vac|303|71|
|110/120 Vac|5260|20.4|
|220/240 Vac|21,000|10.2|
|12 Vdc<br>24 Vdc|75<br>303|158<br>79|
## **D8 Relays**
|**D8 Relays**|||
|---|---|---|
|**Description**|**D8PR6**|**D8PR7**|
|Rated load|220 Vac 30A|220 Vac 25A|
|Carry current<br>Max. operating voltage|30A<br>250 Vac|25A<br>250 Vac|
|Max. switching current<br>Contact material|30A<br>AgCdO|25A<br>AgCdO|
|Max. switching capacity|6600 VA|5500 VA|
|Min. permissible load|100 mA at 5 Vdc|100 mA at 5 Vdc|
|Mechanical life (min.)|5,000,000 operations|5,000,000 operations|
|Electrical life at all contact ratings (min.)<br>Maximum hp ratings|100,000 operations<br>1-1/2 hp (120 Vac)|100,000 operations<br>1-1/2 hp (120 Vac)|
||3 hp (240/265/277 Vac)|3 hp (240/265/277 Vac)|
## **Coil Data**
|**Coil Data**||||
|---|---|---|---|
|**Coil Voltage**<br>24 Vdc/Vac, 12 Vdc|**Must Operate**<br>75% maximum|**Must Release**<br>15% minimum|**Maximum Voltage**<br>110%|
|120 Vac|75V|18V|132V|
|240 Vac|150V|36V|264V|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-102**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D8PR6TF**
**==> picture [327 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.70 (68.5) Max.<br>2.36 (60.0)<br>1.99 (50.5) 1.32 (33.5)<br>Max. Max.<br>0.08 (2.0)<br>0.25 (6.4) 0.03<br>0.43 (0.8) 0 1<br>(11.0)<br>1.85 4 6<br>(47.0)<br>Max.<br>0.12 (3.0) 0.18<br>(4.5) (Top View)<br>**----- End of picture text -----**<br>
**Terminal Arrangement/ Internal Connections (Top View)**
Two 0.18 (4.5) Dia. Holes or M4 Tapped Holes
**==> picture [55 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.362 0.007<br>(60.0 0.2)<br>Mounting Holes<br>(Bottom View)<br>**----- End of picture text -----**<br>
**3**
## **D8PR7TF**
**==> picture [246 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.70 (68.5) Max.<br>2.36 (60.0)<br>1.99 (50.5) 1.32 (33.5)<br>Max. Max.<br>0.08 (2.0)<br>0.25 (6.4) 0.03<br>0.43 (0.8)<br>(11.0)<br>1.85<br>(47.0)<br>Max.<br>0.12 0.18<br>(3.0) (4.5)<br>**----- End of picture text -----**<br>
Two 0.18 (4.5) Dia. Holes or M4 Tapped Holes
**==> picture [180 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
0 1<br>2 4 6 8<br>2.362 0.007<br>(60.0 0.2)<br>Terminal Arrangement/ Mounting Holes<br>Internal Connections (Bottom View)<br>(Top View)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-103**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D8PR6TE with D8PA5 Bracket Attached**
**3**
**==> picture [244 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.07 (52.5) Max.<br>1.99 1.32 (33.5)<br>(50.5) Max. Max.<br>0.08 (2.0)<br>0.25 (6.4) 0.03<br>(0.8)<br>0.43<br>(11.0)<br>2.09<br>(53.0)<br>Max.<br>**----- End of picture text -----**<br>
**==> picture [77 x 80] intentionally omitted <==**
**----- Start of picture text -----**<br>
0 1<br>4 6<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>**----- End of picture text -----**<br>
Two 0.18 (4.5) Dia. Holes or M4 Tapped Holes 1.574 0.003 (40.0 0.1) **Mounting Holes (Bottom View)**
## **D8PR7TE with D8PA5 Bracket Attached**
**==> picture [340 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.07 (52.5) Max.<br>1.99 1.32 (33.5)<br>(50.5) Max. Max<br>0.08 (2.0)<br>0.25 (6.4) 0.03<br>(0.8) 0 1<br>0.43<br>(11.0)<br>2.09 2 4 6 8<br>(53.0)<br>Max.<br>Terminal Arrangement/<br>Internal Connections<br>(Top View)<br>**----- End of picture text -----**<br>
**==> picture [86 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
Two 0.18 (4.5) Dia. Holes<br>or M4 Tapped Holes<br>1.574 0.003<br>(40.0 0.1)<br>Mounting Holes<br>(Bottom View)<br>**----- End of picture text -----**<br>
## **D8PA1**
**==> picture [365 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
Two M4 or<br>0.18 (4.5) Dia. Holes<br>2.03<br>(51.5)<br>Max.<br>1.574 0.003<br>(40.0 0.1)<br>1.574 0.003<br>(40.0 0.1) 0.20<br>(5.0)<br>2.19 (55.5)<br>Max. 0.57 Mounting Holes<br>(14.5) (Bottom View)<br>1.39 (35.2)<br>Max.<br>**----- End of picture text -----**<br>
**Note:** Minimum spacing around relay = 0.20 inches (5 mm).
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-104**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **D8PA2**
**==> picture [169 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
Two M3.5 Screws<br>for Coil 0.31 (8.0)<br>Four M4 Screws 0.36 (9.2)<br>for Contact 1.574 0.003<br>(40.0 0.1)<br>2.19 (55.5)<br>Max.<br>**----- End of picture text -----**<br>
**==> picture [44 x 41] intentionally omitted <==**
## **D8PA5**
**==> picture [235 x 166] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.94<br>0.18 (4.5)Two (40.0)1.57 0.70 (24.0)<br>Dia. Holes (17.8)<br>1.02<br>(26.0)<br>Two M4 or 0.18 (4.5)<br>Dia. Holes 0.39 0.12<br>1.81 (10.0) (3.0)<br>(46.0)<br>0.27 0.17<br>1.574 0.003 0.94 (7.0) (4.4)<br>(40.0 0.1)<br>(24.0)<br>Mounting<br>Holes<br>(Bottom View) 0.78<br>0.20 1.18 0.20 (19.7)<br>(5.0) (30.0) (5.0)<br>1.20 (50.0)<br>**----- End of picture text -----**<br>
**==> picture [216 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
Two M4 or<br>0.18 (4.5) Dia. Holes<br>2.03<br>(51.5)<br>Max.<br>1.574 0.003<br>0.98 (40.0 0.1)<br>(25.0) 0.20<br>(5.0)<br>1.81 (46.0)<br>Max. Mounting Holes<br>(Bottom View)<br>**----- End of picture text -----**<br>
## **PFP-M DIN Rail End Stop**
**==> picture [147 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
M4 Spring Washer<br>0.24<br>M4 x 8 Pan (6.2)<br>Head Screw 0.07<br>(1.8)<br>0.45<br>(11.5) 0.07 1.39<br>(35.3)<br>(1.8)<br>0.19 1.47<br>1.97 (4.8) 0.05 (37.3)<br>(50.0) 0.39 0.39 (1.3)<br>(10.0) (10.0)<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-105**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
**==> picture [45 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
D9 Series Relay<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D1PR/D1PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-46**|
|D2PR/D2PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-51**|
|D3PR/D3PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-61**|
|D4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-71**|
|D5PR/D5PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-75**|
|D7PR/D7PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-85**|
|D8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-100**|
|D9 Series||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-107**|
|Technical Data and Specifications . . . . . . . . . . .|**V7-T3-107**|
|Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-108**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-110**|
## **D9 Series**
## **Product Description**
The four-pole D9 Series is ideal for three-phase motor applications. Various contact configurations are available.
## **Features**
- Ideal for three-phase motor control applications
- No contact chattering for momentary voltage drops up to 50% of rated voltage
- Push-to-Test button is a standard feature to check contact operation
- Mounting bracket is supplied with relay
## **Catalog Number Selection**
**==> picture [186 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
D 9 P R 8 B A<br>Family Type Coil Voltage<br>D9PR A = 120 Vac<br>B = 240 Vac<br>R1 = 12 Vdc<br>Contact Configuration T = 24 Vac<br>8B = 4PST-NO T1 = 24 Vdc<br>9B = 3PST-NO/SPST-NC<br>10B = DPST-NO/DPST-NC<br>**----- End of picture text -----**<br>
## **Standards and Certifications**
File # E1491
File # LR701520
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-106**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Product Selection**
## **D9 Series**
|<br>**Catalog**<br>**Number**<br>**4PST-NO Power Relay**<br>Coil voltage<br>24 Vac<br>**D9PR8BT**<br>120 Vac<br>**D9PR8BA**<br>240 Vac<br>**D9PR8BB**<br>24 Vdc<br>**D9PR8BT1**<br>**3PST-NO/SPST-NC Power Relay**<br>120 Vac<br>**D9PR9BA**|**Catalog**<br>**Number**<br>**DPST-NO/DPST-NC Power Relay**<br>Coil voltage<br>24 Vac<br>**D9PR10BT**<br>120 Vac<br>**D9PR10BA**<br>24 Vac<br>**D9PR10BT1**|**3**|
|---|---|---|
|||**3**|
|||**3**<br>**3**<br>**3**<br>**3**|
## **Technical Data and Specifications**
## **Coil Resistance**
|**Coil Resistance**||
|---|---|
|**Coil Voltage**<br>**Ohms**<br>**mA**<br>24 Vac<br>—<br>75<br>120 Vac<br>—<br>21.6<br>240 Vac<br>—<br>10.8|**Coil Voltage**<br>**Ohms**<br>**mA**|
||12 Vdc<br>72<br>167|
||24 Vdc<br>288<br>83|
||110 Vdc<br>6050<br>18|
## **D9PR Specifications**
|**D9PR Specifications**|||
|---|---|---|
|**Description**|**NO Contacts**<br>**Resistive Load (p.f. = 1)**|**NC Contacts**<br>**Resistive Load (p.f. = 1)**|
|Rated load|220 Vac 25A<br>30 Vdc 25A|220 Vac 8A<br>30 Vdc 8A|
|Carry current|25A|8A|
|Max. operating voltage|250 Vac/125 Vdc|250 Vac/125 Vdc|
|Max. switching current|25A|8A|
|Max. switching capacity|5500 VA|1760 VA|
||750W|240 W|
|Min. permissible load|100 mA at 24 Vdc|100 mA at 24 Vdc|
|Mechanical life (min.)|1,000,000 operations|1,000,000 operations|
|Electrical life at all contact ratings (min.)<br>Maximum hp ratings|100,000 operations<br>1-1/2 hp (120 Vac)|100,000 operations<br>1-1/2 hp (120 Vac)|
||3 hp (240/265/277 Vac)<br>Three-phase 3 hp (240/265/277 Vac) 30,000 cycles<br>Three-phase 5 hp (240/265/277 Vac) 30,000 cycles|3 hp (240/265/277 Vac)<br>Three-phase 3 hp (240/265/277 Vac) 30,000 cycles<br>Three-phase 5 hp (240/265/277 Vac) 30,000 cycles|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-107**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
|**Coil Data**<br>**Coil Voltage**|**Must Operate**|**Must Release**|**Maximum Voltage**|
|---|---|---|---|
|24 Vdc/Vac, 12 Vdc, 110 Vdc|75% maximum|10% minimum|110%|
|120 Vac|75V|18V|132V|
|240 Vac|150V|36V|264V|
## **Terminal Arrangements**
**==> picture [236 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
14 13 14 13 14 13<br>24 23 24 23 24 23<br>34 33 34 33 34 33<br>44 43 42 41 42 41<br>A2 A1 A2 A1 A2 A1<br>D9PR8 D9PR9 D9PR10<br>**----- End of picture text -----**<br>
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D9PR**
**==> picture [281 x 166] intentionally omitted <==**
**----- Start of picture text -----**<br>
Screw Terminal Brackets<br>Ten M3.5<br>1.36<br>(34.5)<br>Max.<br>0.30<br>(7.6) 0.17 Two M4 or<br>(4.3) 0.18 (4.5) Dia.<br>2.52<br>2.17 (64.0)<br>(55.2) 1.70 Max.<br>(43.2)<br>1.378 0.004<br>(35.0 0.1)<br>(51.5)2.03 0.08 Mounting Holes(Bottom View)<br>Max. (2.0)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-108**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.4
General Purpose Plug-In Relays
Approximate Dimensions in Inches (mm)
## **Mounting Bracket**
**==> picture [239 x 186] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.37<br>(35.0) Two M4 or Mounting Holes<br>0.18 (4.5) Dia.<br>Two M4<br>0.95<br>(24.0)<br>1.378 0.004<br>(35.0 1.0)<br>(30.0)1.18 (9.0)0.35 (28.0)1.10<br>0.28<br>1.14 (7.0)<br>(29.0)<br>0.17<br>1.73 (4.4)<br>(44.0)<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-109**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
**3**
**==> picture [36 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Accessories<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D1PR/D1PF Series. . . . . . . . . . . . . . . . . . . . . . . . .<br>D2PR/D2PF Series. . . . . . . . . . . . . . . . . . . . . . . . .<br>D3PR/D3PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-46**<br>**V7-T3-51**<br>**V7-T3-61**|
|D4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>D5PR/D5PF Series. . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-71**<br>**V7-T3-75**|
|D7PR/D7PF Series. . . . . . . . . . . . . . . . . . . . . . . . .<br>D8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-85**<br>**V7-T3-100**|
|D9 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Accessories<br>MOD Modules . . . . . . . . . . . . . . . . . . . . . . . . .<br>Relay Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-106**<br>**V7-T3-111**<br>**V7-T3-112**|
|Coil Bus Jumpers . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-114**|
|Write-On Plastic Labels/ID Tags . . . . . . . . . . . .|**V7-T3-114**|
|Flange Mount Adapters . . . . . . . . . . . . . . . . . .|**V7-T3-115**|
## **Accessories**
## **Accessories Selection Guide**
Eaton offers a variety of simple-to-install relay accessories that allow you to customize the features of a relay system to meet your exact needs.
## _**Circuit Diagrams**_
**Diode Circuit**
**==> picture [88 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
+<br>A2 A1<br>**----- End of picture text -----**<br>
The diode module protects external drive circuitry from inductive voltages generated when removing coil voltages.
## **RC Circuit**
**==> picture [85 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
A2 A1<br>**----- End of picture text -----**<br>
Snubs back EMF of relay coil.
## **The MOD Module System**
Eaton’s plug-in modules are a simple way to add functionality to your relay without the hassle of messy wiring and additional mounting of external electronics. They are available in a variety of configurations to meet the needs of almost any application.
## **LED Circuit**
**==> picture [89 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
+<br>A2 A1<br>**----- End of picture text -----**<br>
The LED status lamp verifies that power is being supplied to the coil. Ideal for both AC and DC applications. Polarity sensitive for DC applications.
**Metal Oxide Varistor (MOV) Circuit**
**==> picture [85 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
A2 A1<br>**----- End of picture text -----**<br>
The MOV circuit protects by shunting potentially damaging electrical spikes away from the relay coil. Ideal for AC and DC applications.
## _**System Diagrams**_
**The MOD Module System**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-110**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **MOD Modules**
Eaton’s relay accessories provide a complete solution for add-on modules and identification tags.
## **MOD Modules**
||**Module**|||**Catalog**|**Mating**|
|---|---|---|---|---|---|
|**MOD-AD250**|**Size**<br>A|**Description**<br>Protection diode|**Nominal Voltage**<br>6–250 Vdc|**Number**<br>**MOD-AD250**|**Sockets**<br>D3PA6, D3PAL8,|
||||||D3PA7, D3PAL11,|
|mi|||||D5PAL, D7PAB,<br>D7PAD|
|**MOD-RC_**||R/C suppressor|6–24 Vac|**MOD-RC24**||
||||110–240 Vac|**MOD-RC240**||
|ss||||||
|**MOD-ALG_**||LED indicator|24 Vac|**MOD-ALG24**||
|2.|||120/240 Vac|**MOD-ALG240**||
|**MOD-AMV_**||MOV suppressor|24 Vac|**MOD-AMV24**||
||||120 Vac<br>240 Vac|**MOD-AMV120**<br>**MOD-AMV240**||
|Py||||||
|**MOD-BD250**|B|Protection diode|6–250 Vdc|**MOD-BD250**|D1PAA, D2PAL,|
|=<br>Ry|||||D2PAP, D2PA7,<br>D7PAA|
|7.||||||
|**MOD-BLG_**||LED indicator|24 Vac|**MOD-BLG24**||
|=<br>ty|||120/240 Vac|**MOD-BLG240**||
|**MOD-BMV_**<br>,q||MOV suppressor|24 Vac|**MOD-BMV24**||
||||120 Vac|**MOD-BMV120**||
||||240 Vac|**MOD-BMV240**||
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-111**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## **Relay Clips**
|**3**|**Relay Clips**||||||
|---|---|---|---|---|---|---|
|**3**<br>**3**|Eaton offers a variety of relay<br>clips designed to improve the<br>performance and<br>functionality within an<br>electrical panel.||**PMC-1781**|**Metal Hold-Down Clips**<br>**Catalog**<br>**Number**<br>**PMC-1781**|**Metal Hold-Down Clips**<br>**Mating Sockets**<br>D1PAA|**Mating Relays**<br>D1PR, D1PF|
|**3**<br>**3**<br>**3**|**_Metal Hold-Down Clips_**<br>Metal hold-down clips, or<br>spring clips, are ideal for use<br>where high heat or humid<br>conditions are a factor. These<br>clips hold their shape and|**PQC-1782**<br>**PQC-1782**<br>~~S~~|||D2PAL, D2PAP, D2PA7|D2PR2, D2PF2, D2PR3, D2PF4|
|**3**<br>**3**<br>**3**|tension and are designed<br>to withstand harsh<br>environments. All clips<br>are made of corrosion-<br>resistant stainless steel.|~~TF~~|||||
||||**PQC-1342**|**PQC-1342**|D2PA6, D7PAA, D7PA9|D2PR4, D2PF4|
|**3**<br>**3**||a|||||
|**3**|||**PQC-1332**|**PQC-1332**|D3PA6, D3PA7|D3PR2, D3PF2, D3PR3, D3PF3|
|**3**<br>**3**||+t|||||
|**3**|||**PQC-1351**|**PQC-1351**|D3PAL8, D3PA2, D3PAL11, D3PA3,|D3PR2, D3PF2, D3PR3, D3PF4, D5PR, D5PF|
||||||D5PAL, D5PA2, D5PA3L, D5PA3S||
|**3**|||||||
|**3**|||||||
|**3**|||**PQC-1783**|**PQC-1783**|D7PAB|D7PR1, D7PF1, D7PR2, D7PF3|
|**3**<br>**3**||?|||||
|**3**|||**PQC-1784**|**PQC-1784**|D7PAD|D7PR4, D7PF4|
|**3**<br>**3**||C|||||
|**3**||Y|**PYC- _**<br>Y|**PYC-A1**<br>**PYC-B2**|D2PA4<br>D7PA3, D7PA4|D2PR5<br>D7PR1, D7PR2, D7PR4|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-112**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## _**Plastic Ejector/ Hold-Down Clips**_
**==> picture [503 x 370] intentionally omitted <==**
**----- Start of picture text -----**<br>
These clips are great for PWC-D24 Plastic Ejector/Hold-Down Clips<br>applications where sockets<br>Catalog<br>are located in dense or tight Number Mating Sockets Mating Relays<br>areas. They allow for quick,<br>safe and firm securing of PWC-D24 D2PAL, D2PAP, D2PA7 D2PF2, D2PF4<br>relays in the sockets with the<br>added benefit that the relay<br>can be ejected with one<br>finger. Plastic clips also aid in<br>5<br>keeping operators’ fingers<br>away from live circuits. The<br>optional snap-in identification<br>tag allows for custom<br>marking of sockets when<br>used in multi-socket<br>applications.<br>Plastic ID Clips Plastic ID Clips<br>Plastic ID clips allow for easy Catalog<br>circuit identification in multi- Number Mating Sockets Mating Relays<br>relay applications. They are PQC-1349 PQC-1349 D7PAA D7PF1, D7PF2<br>designed for labeling and<br>are not ideal for securing<br>the relay in the socket.<br>sO<br>PMC-1783 PMC-1783 D7PAB D7PF1, D7PF2<br>%<br>PMC-1784 PMC-1784 D7PAD D7PF4<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-113**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## _**Coil Bus Jumpers**_
Eaton’s coil bus jumpers allow inputs to be bridged **3** to adjacent sockets without additional wiring, making **3** multi-relay connections quick and easy. The easy-to-install **3** design requires no tools and can be complete in a matter of seconds.
## **System Diagrams**
## **Coil Bus Jumpers**[1]
**==> picture [201 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
Coil Bus Jumpers<br>Catalog<br>Number Mating Sockets<br>D2PJ1 D2PJ1 D2PAL, D2PAP<br>es<br>D3PJ1 D3PJ1 D3PA6, D3PA7, D5PAL<br>**----- End of picture text -----**<br>
## _**Write-On Plastic Labels/ID Tags**_
These convenient plastic labels snap easily onto the relay socket for clear identification in multi-relay panels. The hinged design makes wiring simple and allows for angular adjustment of the tag to improve readability in the panel. Marking with a standard permanent marker creates a smudge-free surface.
## **Write-On Plastic Labels/ID Tags**
**==> picture [225 x 200] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog<br>Number Mating Sockets<br>PWF-D2P PWF-D2P D2PAL, D2PAP<br>4 rs ,<br>\<br>PWF-D3D5 PWF-D3D5 D3PAL8, D3PAL11, D5PAL<br>cet<br>Note<br>1 Jumpers in photo are colored green to improve visibility,<br>actual jumpers are black.<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-114**
Control Relays and Timers
3.4
General Purpose Plug-In Relays
## _**Flange Mount Adapters**_
**==> picture [374 x 258] intentionally omitted <==**
**----- Start of picture text -----**<br>
Eaton’s relay flange mount Flange Mount Adapters<br>adapters create a modular Catalog<br>approach to flexible Number Mating Relay<br>mounting options. Each low-<br>cost adapter allows for panel PFC-D11 PFC-D11 D1PF1, D1PR1<br>mounting of a standard<br>control relay and can<br>eliminate the need for<br>a socket.<br>Unit with Flange Mount PFC-D2D72 PFC-D2D72 D2P, D7PF2, D7PR2<br>Adapter<br>~ ay r| Se PFC-D73 PFC-D73 D7PF3, D7PR3<br>PFC-D74 PFC-D74 D7PF4, D7PR4<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-115**
Control Relays and Timers
3.5
General Purpose Relays—Type AA
**3**
**==> picture [68 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
9575H Series 3000 Relay<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|9575H Series 3000—Type AA, AC and DC||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-117**|
|Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-117**|
|Technical Data and Specifications . . . . . . . . . . .|**V7-T3-118**|
|Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-119**|
## **9575H Series 3000—Type AA, AC and DC**
## **Product Description**
Type AA panel-mounted relays are rated (each pole) 40A up to 300 Vac, 50/60 Hz; 5A at 480/600 Vac, 50/60 Hz and 40A at 28 Vdc.
## **Application Description**
9575H Series 3000 relays are ideal for applications when controlling smaller loads, such as single-phase motors.
## **Standards and Certifications**
- UL listed, E1491
- CSA 41729
- CE: EN60947-4-1, EN60947-5-1
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-116**
Control Relays and Timers
3.5
General Purpose Relays—Type AA
## **Product Selection**
## _**When Ordering, Specify**_
Catalog number and magnet coil code letter. Example: for DPDT relay with auxiliary
switch and a 120V 50/60 Hz coil, order Catalog Number 9575H3A010.
**Type AA Relays**[1]
||**Type AA Relays**[1]||
|---|---|---|
|**9575H Series 3000**|**Type AA Relays**[1]||
|**Relay**||**Catalog**|
|rredt<br>ae<br>a<br>= +r<br>!<br>fl<br>i<br>e<br>= =<br>eed|**Relay Style**<br>Relay (DPDT)<br>Relay with auxiliary switch<br>Relay with blowout magnets<br>~~Tamm!~~|**Number**2<br>**9575H3_000**<br>**9575H3_010**<br>**9575H3_100**<br>~~Tamm!~~|
||Relay with auxiliary switch and<br>blowout magnets|**9575H3_110**|
## **Coil Voltage Selection**
||**Coil Voltage**<br>~~SS~~|**Hz**<br>~~SS~~|**Suffix Code**<br>~~SS~~|
|---|---|---|---|
||**Volts AC**|||
||120|50/60|**A**|
||240|50/60|**B**|
||480/440|60/50|**C**|
|600/550<br>208<br>~~CCF~~||60/50<br>50/60<br>~~TSS TT~~|**D**<br>**E**|
||277|50/60|**H**|
||6|50/60|**J**|
||12|50/60|**K**|
||24|50/60|**L**|
||48|50/60|**M**|
||**Volts DC**<br>110|—|**P**|
||220|—|**Q**|
||6|—|**R**|
||12|—|**S**|
||24|—|**T**|
||48|—|**W**|
**3**
## **Accessories**
**Enclosure**[3]
|**Description**<br>**Catalog**<br>**Number**<br>NEMA 1 Enclosure<br>**9575H2449**<br>~~——SS~~|
|---|
## _**Notes**_
- 1 There are no “repair parts” available for these relays.
- 2 Underscore indicates missing code suffix for magnet coil—see Selection table above.
- 3 Only 9575H3 relays without an auxiliary switch should be mounted in the 9575H2449 enclosure.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-117**
Control Relays and Timers
3.5
## General Purpose Relays—Type AA
## **Technical Data and Specifications**
## _**Relay Specifications**_
## _**Coil**_
- **3** ● Pull-in voltage: 80% DC coils, 85% AC coils
- **3** of nominal voltage or less at 25ºC
- Dropout voltage: 10% of nominal voltage or more at 25ºC
- Coil resistance: ±10% measured at 25ºC
- Max. DC coil dissipation capability: 4 watts DC continuous at 25ºC
## _**Contacts**_
- Contact combination: DPDT
- Contact rating each pole (main contacts): Each pole rated 40 amps up to 300 Vac, 50/60 Hz, 5 amps at 480/600 Vac 50/60 Hz, 0.75 PF load. 1-1/2 hp motor load (each pole) at 120–600 Vac, 50/60 Hz. 2 hp motor load at 200–600 Vac, 50/60 Hz only when using both poles to switch both sides of load, 40 amps at 28 Vdc resistive load each pole. NEMA A 600 pilot duty 50/60 Hz
- Additional contact ratings for relays with blowout magnets: 10A at 110 Vdc resistive, 4A at 225 Vdc resistive, 2A at 325 Vdc resistive. For inductive loads, contacts must be derated accordingly.
## _**Auxiliary Switch Specifications**_
## _**Dielectric Withstanding Voltage**_
- Contact combination: SPDT
- Between open contacts: 1500 Vrms
- Contact rating: Auxiliary switch rated 10 amps at 125 or 250 Vac, resistive load; 1/4 hp at 125 or 250 Vac, motor load; 0.4 amps at 125 Vdc or 0.20 amps at 250 Vdc, resistive load; 3 amps at 125 Vac lamp load. All AC ratings are 50/60 Hz
- All other mutually insulated conductive elements: 2200 Vrms
## _**Miscellaneous**_
- Coil terminals: 6–32 screws
- Contact terminals: 8-–32 screws
- Dielectric withstanding voltage: 500 Vac rms between open contacts, 1500 Vac rms between all other mutually insulated conductive elements
- Main base material: Molded phenolic, UL recognized (QMFZ2)
- Weight (DPDT Relay): 11 oz (311 grams) approximately
- Terminals: 4–40 round
- ● Weight (DPDT Relay with head screws for auxiliary auxiliary switch) 14.5 oz contacts standard (411 grams) approximately
- Contact material: Silver cadmium oxide, gold flashed. 5/16 in
- (7.9 mm) diameter standard
**Average Operating Times (Milliseconds)**
|**Operation**|**DPDT Relay**|**DPDT Relay with Auxiliary Switch**|
|---|---|---|
|Pickup|40|50|
|Dropout|35|35|
|**Temperature Ranges**|||
|**Temperature**|**AC**|**DC**|
|Operating range|–30º to 55ºC|–30º to 55ºC|
|Non-operating range|–30º to 100ºC|–30º to 100°C|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-118**
Control Relays and Timers
3.5
General Purpose Plug-In Relays—Type AA
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **9575H3 DPDT Relay**
## **9575H2449**
**==> picture [489 x 310] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mounting Holes 0.187 (4.75) Dia. (2 Places) 3.31"<br>(84.2)<br>1.88"<br>8-32 Machine Screw on (47.6)<br>Contact Terminals (6 Places)<br>0.56" 0.218" 0.230" (5.8)<br>(4.3) (5.5)Dia. Square Hole<br>2.25<br>(58.7)<br>Max.<br>3.55" 0.159" (4) Dia.<br>(90.1) 10-32 Tap<br>1.62 Typ. 4 Places<br>1.87 (47.5) 0.38 (41.1)<br>2.50 (63.5) (9.5) 3.12 (79.2) Max. (114.3)4.50"<br>6-32<br>Machine Screw 5.63"<br>on Coil (142.9) 0.136" (3.4) Dia.<br>Terminals 0.50" 8-32 Tap<br>(2 Places) (2.7) Typ. 2 Places<br>2.00" 3.00"<br>9575H3 DPDT Relay with Auxiliary SPDT Switch (50.8) (76.2)<br>0.218" (5.5) Dia. 0.36" (9.1)<br>Typ. 2 Places Typ. 2 Places<br>Mounting Holes 0.187 (4.75) Dia. (2 Places)<br>8-32 Machine Screw on<br>Contact Terminals (6 Places)<br>2.25<br>(58.7) 0.20"<br>Max. (5.1)<br>**----- End of picture text -----**<br>
**==> picture [233 x 343] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mounting Holes 0.187 (4.75) Dia. (2 Places)<br>8-32 Machine Screw on<br>Contact Terminals (6 Places)<br>2.25<br>(58.7)<br>Max.<br>1.62<br>1.87 (47.5) 0.38 (41.1)<br>2.50 (63.5) (9.5) 3.12 (79.2) Max.<br>6-32<br>Machine Screw<br>on Coil<br>Terminals<br>(2 Places)<br>NC<br>10A 1/4 hp 125 OR 250 Vac<br>0.4A at 125 Vdc, 0.2A at 250 Vdc<br>3A 125 Vac “LAMP”<br>278 VA 125/250 Vac P.D.<br>NO COM<br>Mounting Holes (2)<br>AUX. SWITCH<br>MARKING SURFACE<br>Insulators<br>(2 Sides)<br>Screw Terminals<br>(4-40) RHMS<br>with External<br>4.44 (112.7) Max. Tooth Lockwashers<br>(3 Places)<br>RELAY TOP VIEW<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-119**
Control Relays and Timers
3.6
Solid-State Relays
**3** ~~ms~~ **3**
## **Solid-State Relays**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Solid-State Relays||
|D93 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>D96 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>D99 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-121**<br>**V7-T3-128**<br>**V7-T3-133**|
## **Product Overview**
## **Catalog Number Selection**
## **Solid-State Relays—D93, D96 and D99 Series**
**==> picture [283 x 239] intentionally omitted <==**
**----- Start of picture text -----**<br>
D 9 3 3 2 5 A M D 2<br>Description Input Voltage<br>D93 = Hockey puck 1 = 90–280 Vac<br>D96 = Compact 2 = 3–32 Vdc<br>D99 = DIN rail 3 = 3.5–32 Vdc<br>4 = 4–15 Vdc<br>5 = 20–50 Vdc<br>Output Voltage<br>1 = 2–60 Vdc<br>2 = 24–280 Vac Turn On Type<br>3 = 3–200 Vdc Z = Zero cross<br>4 = 48–480 Vac R = Random<br>6 = 48–600 Vac D = DC switch<br>Current Output Type<br>Output current in amps C = SCR<br>T = Triac<br>M = MOSFET<br>Contact Configuration<br>A = SPST-NO<br>B = SPST-NC<br>C = DPST-NO<br>D = DPST-NC<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-120**
Control Relays and Timers
3.6
Solid-State Relays
## **D93 Series—Solid-State Relays**
## **Contents**
|**Contents**||**3**|
|---|---|---|
|**_Description_**|**_Page_**||
|D93 Series||**3**|
|Product Selection . . . . . . . . . . . . . . . . . . . . .|**V7-T3-122**||
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-122**|**3**|
|Technical Data and Specifications . . . . . . . . . .<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-123**<br>**V7-T3-127**|**3**|
|D96 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>D99 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-128**<br>**V7-T3-133**|**3**|
## **D93 Series**
## **Product Description**
Eaton’s D93 series of solidstate relays is a line of heavyduty industrial relays in the common “hockey puck” package. The removable, finger-safe cover and optional accessories make the D93 safe and easy to install in a variety of applications.
Models are available in a variety of input voltages and switch types up to 75A.
## **Application Description**
A solid-state relay (SSR) can perform many applications that an electromechanical relay can perform. The SSR differs in that it has no moving mechanical parts within it and has some distinct advantages over an electromechanical relay.
When used correctly in the intended application, the SSR provides a high degree of reliability, a long service life, significantly reduced electromagnetic interference, fast response and high vibration resistance.
## **Features and Benefits**
- All solid-state circuitry with no moving parts to wear
- Compact, panel mounting for flexible installation
- Isolated input and output terminals to protect the system from electrical noise
- Internal snubber circuitry to protect the SSR from transients
## **Standards and Certifications**
- UL/cUL listed—UL 508
- CSA certified
- CE marked
- RoHS compliant
Applications for the SSR typically include equipment that requires high cycling rates, low acoustical or electrical noise, or high vibration resistance. Some examples are medical equipment, heating/cooling equipment, lighting control and pumps/compressors, among others.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-121**
Control Relays and Timers
3.6
## Solid-State Relays
## **Product Selection**
**3**
## **D93 Series**
**D93210ACZ1**
|**D93210ACZ1**|**D93 Series**||||||
|---|---|---|---|---|---|---|
||||**Contact**||**Rated Current**||
||**Input Voltage**<br>90–280 Vac|**Output Voltage**<br>24–280 Vac|**Configuration**<br>SPST-NO|**Switching Type**<br>Zero cross|**Load (Amps)**<br>10|**Catalog Number**<br>**D93210ACZ1**|
|3–32 Vdc<br>24–280 Vac<br>SPST-NO<br>Zero cross<br>10<br>**D93210ACZ2**<br>—~~———————~~|||||||
||3–32 Vdc|24–280 Vac|SPST-NO|Triac|10|**D93210ATZ2**|
||90–280 Vac|24–280 Vac|SPST-NO|Zero cross|25|**D93225ACZ1**|
||3–32 Vdc<br>3–32 Vdc|24–280 Vac<br>24–280 Vac|SPST-NO<br>SPST-NO|Zero cross<br>Triac|25<br>25|**D93225ACZ2**<br>**D93225ATZ2**|
||90–280 Vac|24–280 Vac|SPST-NO|Zero cross|40|**D93240ACZ1**|
||3–32 Vdc|24–280 Vac|SPST-NO|Zero cross|40|**D93240ACZ2**|
||3–32 Vdc|24–280 Vac|SPST-NO|Triac|40|**D93240ATZ2**|
||90–280 Vac|24–280 Vac|SPST-NO|Zero cross|50|**D93250ACZ1**|
||3–32 Vdc|24–280 Vac|SPST-NO|Zero cross|50|**D93250ACZ2**|
||90–280 Vac<br>3–32 Vdc|24–280 Vac<br>24–280 Vac|SPST-NO<br>SPST-NO|Zero cross<br>Zero cross|75<br>75|**D93275ACZ1**<br>**D93275ACZ2**|
||3–32 Vdc|3–200 Vdc|SPST-NO|MOSFET|12|**D93312AMD2**|
||3–32 Vdc|3–200 Vdc|SPST-NO|MOSFET|25|**D93325AMD2**|
||3–32 Vdc|3–200 Vdc|SPST-NO|MOSFET|40|**D93340AMD2**|
## **Accessories**
**==> picture [24 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
D93HS1<br>**----- End of picture text -----**<br>
## _**D93 Series—Heat Sink**_
**==> picture [23 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
D93TP1<br>**----- End of picture text -----**<br>
Eaton’s D93HS1 heat sink is specifically designed to be used with D93 solid-state relays. It is pre-drilled and tapped, and matches the heat —[nemo] dissipation requirements for relays up to 50A. **Heat Sink Accessory Catalog Description Number** ~~ee~~ Heat sink **D93HS1** ia
## _**D93 Series—Thermal Transfer Pad**_
The D93TP1 is a selfadhesive transfer pad designed for use with Eaton’s D93 solid-state relays. When used properly, it will adequately conduct the heat to a heat sink without the use of grease.
**Note:** Always ensure that all details of the application are considered when determining heat dissipation requirements, including ambient temperature. The D93 relays must be firmly mounted to the heat sink using a suitable thermally conductive grease or thermal transfer pad.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-122**
Control Relays and Timers
3.6
Solid-State Relays
## **Technical Data and Specifications**
|**D93 Series**||||||||
|---|---|---|---|---|---|---|---|
|**Description**|**Units**|**D93210ACZ1**|**D93210ACZ2**|**D93210ATZ2**|**D93225ACZ1**|**D93225ACZ2**|**D93225ATZ2**|
|**Output Characteristics**||||||||
|Contact configuration||SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NO|
|Switching device<br>Current rating|A|SCR<br>10|SCR<br>10|Triac<br>10|SCR<br>25|SCR<br>25|Triac<br>25|
|Switching type<br>Maximum rate of rise off state voltage (DV/DT)|V/us|Zero cross<br>200|Zero cross<br>250|Zero cross<br>700|Zero cross<br>500|Zero cross<br>500|Zero cross<br>250|
|Incandescent lamp ampere rating (rms)|A|8|16|16|16|16|16|
|Motor load rating (rms)|A|4.5|8|8|8|8|8|
|Min. load current to maintain on|mA|50|120|250|120|120|120|
|Non-repetitive surge current (1 cycle)<br>Max. rms overload current (1 second)|A<br>A|83<br>24|250<br>80|1000<br>50|250<br>40|250<br>40|250<br>80|
|Max. off state leakage current (rms)|mA|8|10|10|8|10|10|
|Peak blocking voltage|Vpk|600|300|—|600|600|—|
|Typical on state voltage drop (rms)|Vac|1.6|1.6|1.35|1.6|1.6|1.6|
|Max. on state voltage drop (rms)|Vac|1.6|1.6|1.6|1.6|1.6|1.6|
|Max. I2t for fusing (A2)||72|300|1700|312|250|300|
|**Input Characteristics**<br>Must release voltage|V|10 AC|1 DC|10 AC|10 AC|1 DC|1 DC|
|Typical input impedance|ohms|13k|Current regulator|16–25k|13k|Current regulator|1.5k|
|Nominal input current at 5 Vdc or 240 Vac|mA|20|2|12|20|16|2|
|Reverse polarity protection||NA|Yes|NA|NA|Yes|Yes|
|**Performance Characteristics**||||||||
|Operating time (response time)||||||||
|ON<br>OFF|ms<br>ms|8.3<br>8.3|8.3<br>8.3|8.3<br>8.3|8.3<br>8.3|8.3<br>8.3|8.3<br>8.3|
|Rated insulation voltage—input to input|Vac|4000|4000|4000|4000|4000|4000|
|Dielectric strength—terminal to chassis|Vac|4000|4000|4000|4000|4000|4000|
|**Environment**||||||||
|Product certifications<br>Ambient air temperature||UR, CSA, CE|UR, CSA, CE|UR, CSA, CE|UR, CSA, CE|UR, CSA, CE|UR, CSA, CE|
|Storage|°C|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|
|Operating|°C|–40 to 80|–40 to 80|–40 to 80|–40 to 80|–40 to 80|–40 to 80|
|Degree of protection||IP20|IP20|IP20|IP20|IP20|IP20|
|**Miscellaneous Characteristics**||||||||
|Thermal resistance (junction to case)|°C/W|3.5|3.5|1.45|1.02|1.02|1.45|
|Weight<br>LED—input|g (oz)|100 (3.5)<br>Green|100 (3.5)<br>Green|100 (3.5)<br>Green|100 (3.5)<br>Green|100 (3.5)<br>Green|100 (3.5)<br>Green|
|Input terminals||M3.5|M3.5|M3.5|M3.5|M3.5|M3.5|
|Output terminals||M4|M4|M4|M4|M4|M4|
|Terminal torque (max.)|Nm|1.0|1.0|1.0|1.0|1.0|1.0|
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-123**
3.6
**3**
## Control Relays and Timers
## Solid-State Relays
## **D93 Series, continued**
|**D93 Series, continued**|||||||
|---|---|---|---|---|---|---|
|**Description**|**Units**|**D93240ACZ1**|**D93240ACZ2**|**D93240ATZ2**|**D93250ACZ1**|**D93250ACZ2**|
|**Output Characteristics**|||||||
|Contact configuration||SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NO|
|Switching device||SCR|SCR|Triac|SCR|SCR|
|Current rating<br>Switching type|A|40<br>Zero cross|40<br>Zero cross|40<br>Zero cross|50<br>Zero cross|50<br>Zero cross|
|Maximum rate of rise off state voltage (DV/DT)|V/us|500|500|250|500|500|
|Incandescent lamp ampere rating (rms)|A|30|30|20|39|39|
|Motor load rating (rms)|A|14|14|14|14|14|
|Min. load current to maintain on|mA|250|250|50|250|250|
|Non-repetitive surge current (1 cycle)|A|625|625|250|520|520|
|Max. rms overload current (1 second)<br>Max. off state leakage current (rms)|A<br>mA|80<br>10|80<br>10|80<br>10|100<br>10|100<br>8|
|Peak blocking voltage|Vpk|600|600|600|600|600|
|Typical on state voltage drop (rms)|Vac|1.6|1.6|1.6|1.1|1.8|
|Max. on state voltage drop (rms)|Vac|1.6|1.6|1.6|1.8|1.8|
|Max. I2t for fusing (A2)<br>**Input Characteristics**||1250|1250|438|1250|1250|
|Must release voltage|V|10 AC|1 DC|1 DC|10 AC|1 DC|
|Typical input impedance|ohms|13k|ACL|1.5k|13k|Current regulator|
|Nominal input current at 5 Vdc or 240 Vac|mA|20|16|2|20|16|
|Reverse polarity protection||N/A|Yes|Yes|NA|Yes|
|**Performance Characteristics**|||||||
|Operating time (response time)<br>ON|ms|8.3|8.3|8.3|8.3|8.3|
|OFF|ms|8.3|8.3|8.3|8.3|8.3|
|Rated insulation voltage—input to input|Vac|4000|4000|4000|4000|4000|
|Dielectric strength—terminal to chassis|Vac|4000|4000|4000|4000|4000|
|**Environment**|||||||
|Product certifications||UR, CSA, CE|UR, CSA, CE|UR, CSA, CE|UR, CSA, CE|UR, CSA, CE|
|Ambient air temperature<br>Storage|°C|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|
|Operating|°C|–40 to 80|–40 to 80|–40 to 80|–40 to 80|–40 to 80|
|Degree of protection||IP20|IP20|IP20|IP20|IP20|
|**Miscellaneous Characteristics**|||||||
|Thermal resistance (junction to case)<br>Weight|°C/W<br>g (oz)|0.9<br>100|0.9<br>100|0.95<br>100|0.63<br>135 (4.8)|0.63<br>135 (4.8)|
|LED—input||Green|Green|Green|Green|Green|
|Input terminals||M3.5|M3.5|M3.5|M3.5|M3.5|
|Output terminals||M6|M6|M6|M6|M6|
|Terminal torque (max.)|Nm|1.0|1.0|1.0|1.0|1.0|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-124**
Control Relays and Timers
3.6
Solid-State Relays
**3**
## **D93 Series, continued**
|**D93 Series, continued**|||||||
|---|---|---|---|---|---|---|
|**Description**|**Units**|**D93275ACZ1**|**D93275ACZ2**|**D93312AMD2**|**D93325AMD2**|**D93340AMD2**|
|**Output Characteristics**|||||||
|Contact configuration||SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NO|
|Switching device||SCR|SCR|MOSFET|MOSFET|MOSFET|
|Current rating<br>Switching type|A|75<br>Zero cross|75<br>Zero cross|12<br>DC switching|25<br>DC switching|40<br>DC switching|
|Maximum rate of rise off state voltage (DV/DT)|V/us|500|500|NA|NA|NA|
|Incandescent lamp ampere rating (rms)|A|39|39|NA|NA|NA|
|Motor load rating (rms)|A|25|25|NA|NA|NA|
|Min. load current to maintain on|mA|250|250|20|20|20|
|Non-repetitive surge current (1 cycle)|A|1150|1150|27|50|90|
|Max. rms overload current (1 second)<br>Max. off state leakage current (rms)|A<br>mA|150<br>10|150<br>10|NA<br>8|NA<br>8|NA<br>8|
|Peak blocking voltage|Vpk|600|600|—|—|—|
|Typical on state voltage drop (rms)|Vac|1.8|1.8|1.6|1.6|1.6|
|Max. on state voltage drop (rms)|Vac|1.8|1.8|2.83|2.83|2.83|
|Max. I2t for fusing (A2)<br>**Input Characteristics**||5000|5000|NA|NA|NA|
|Must release voltage<br>Typical input impedance|V<br>ohms|10 AC<br>13k|1 DC<br>Current regulator|1 DC<br>1k|1 DC<br>1k|1 DC<br>1k|
|Nominal input current at 5 Vdc or 240 Vac|mA|20|16|10|10|10|
|Reverse polarity protection||NA|Yes|No|No|No|
|**Performance Characteristics**|||||||
|Operating time (response time)<br>ON|ms|8.3|8.3|300 μs|600 μs|600 μs|
|OFF|ms|8.3|8.3|1|2.6|2.6|
|Rated insulation voltage—input to input|Vac|4000|4000|4000|4000|4000|
|Dielectric strength—terminal to chassis|Vac|4000|4000|2500|2500|2500|
|**Environment**|||||||
|Product certifications||UR, CSA, CE|UR, CSA, CE|UR, CSA, CE|UR, CSA, CE|UR, CSA, CE|
|Ambient air temperature<br>Storage|°C|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|
|Operating|°C|–40 to 80|–40 to 80|–40 to 80|–40 to 80|–40 to 80|
|Degree of protection||IP20|IP20|IP20|IP20|IP20|
|**Miscellaneous Characteristics**|||||||
|Thermal resistance (junction to case)<br>Weight|°C/W<br>g (oz)|0.6<br>200|0.63<br>135 (4.8)|1.06<br>110 (3.9)|1.06<br>110 (3.9)|0.63<br>135 (4.8)|
|LED—input<br>Input terminals||Green<br>M3.5|Green<br>M3.5|Green<br>M3.5|Green<br>M3.5|Green<br>M3.5|
|Output terminals||M6|M6|M4|M4|M6|
|Terminal torque (max.)|Nm|1.0|1.0|1.0|1.0|1.0|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-125**
Control Relays and Timers
3.6
Solid-State Relays
## _**Temperature Derating Curves**_
## **10 Amp Styles**
**==> picture [239 x 379] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 16<br>3 14 6" x 6" x 1/8" aluminum plate<br>12<br>3 Heat sink<br>10 with 1°C/W<br>3 thermal<br>8 resistance<br>3 6<br>3 4<br>Free air mounting<br>2<br>3<br>0<br>20° 40° 60° 80° 100°<br>3<br>Max. Ambient Temperature (°C)<br>3<br>3 25 Amp Styles<br>40<br>3 Mounted on heat sink with<br>35 1°C/W thermal resistance<br>3 30 (sink to ambient)<br>3 25<br>3 20<br>15<br>3 5" x 6" x 1/8"aluminum<br>10 plate<br>3 5 1.5°C/W<br>3<br>20° 40° 60° 80° 100°<br>3 Max. Ambient Temperature (°C)<br>Load Current (amps rms)<br>Load Current (amps rms)<br>**----- End of picture text -----**<br>
## **40 and 50 Amp Styles**
**==> picture [195 x 364] intentionally omitted <==**
**----- Start of picture text -----**<br>
90<br>Mounted on heat sink with<br>80<br>1°C/W thermal resistance<br>70<br>0.14°C/W (50A)<br>50<br>40 5" x 6" x 1/8"<br>aluminum plate<br>30<br>20<br>10<br>0<br>20° 40° 60° 80° 100°<br>Max. Ambient Temperature (°C)<br>75 Amp Styles<br>75<br>90<br>60<br>95<br>5" x 6" x 1/8"<br>aluminum plate<br>45 1 00<br>0.14°C/W<br>40<br>1 05<br>30<br>20 110<br>10<br>0<br>0° 10° 20° 30° 40° 50° 60° 70° 80°<br>Max. Ambient Temperature (°C)<br>Load Current (amps rms)<br>Load Current (amps rms)<br>Max. Allowable Temperature<br>**----- End of picture text -----**<br>
## **75 Amp Styles**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-126**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.6
Solid-State Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D93 Series**
**==> picture [328 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.28 0.66 Screw Terminals<br>(57.9)<br>(16.8)<br>0.18<br>(4.4)<br>0.6<br>(15.1)<br>1.74<br>(44.1)<br>1.87<br>1.4 (47.5)<br>(35.9)<br>2.28<br>(57.9)<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-127**
Control Relays and Timers
3.6
Solid-State Relays
**3**
## **D96 Series—Solid-State Relays**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D93 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-121**|
|D96 Series||
|Product Selection . . . . . . . . . . . . . . . . . . . .|**V7-T3-129**|
|Technical Data and Specifications . . . . . . . . . .|**V7-T3-130**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-132**|
|D99 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-133**|
## **D96 Series**
## **Product Description**
Eaton’s D96 series of solid-state relays is a technologically advanced set of electronic relays for tough applications and harsh environments. The compact 17.5 mm wide package with an integrated heat sink provides easy mounting in tight spaces.
## **Application Description**
A solid-state relay (SSR) can perform many applications that an electromechanical relay can perform. The SSR differs in that it has no moving mechanical parts within it and has some distinct advantages over an electromechanical relay.
When used correctly in the intended application, the SSR provides a high degree of reliability, a long service life, significantly reduced electromagnetic interference, fast response and high vibration resistance.
## **Standards and Certifications**
## **Features and Benefits**
- All solid-state circuitry has no moving parts to wear
- UL/cUL listed—UL 508
- CSA certified
- Integral heat sink ● CE marked eliminates the need for ● RoHS compliant added accessories and installation
- Flexible mounting allows DIN rail or panel mounting without additional hardware or tools
- Isolated input and output terminals protect the system from electrical noise
- Internal snubber circuitry protects the SSR from transients
Applications for the SSR typically include equipment that requires high cycling rates, low acoustical or electrical noise, or high vibration resistance. Some examples are medical equipment, heating/cooling equipment, lighting control and pumps/compressors, among others.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-128**
Control Relays and Timers
3.6
Solid-State Relays
**3**
## **Product Selection**
**==> picture [118 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
D96115ACZ3 D96 Series<br>**----- End of picture text -----**<br>
|**D96 Series**||||||
|---|---|---|---|---|---|
|||**Contact**||**Rated Current**||
|**Input Voltage**<br>3.5–32 Vdc<br>3.5–32 Vdc<br>90–280 Vac<br>3–32 Vdc|**Output Voltage**<br>3–50 Vdc<br>3–150 Vdc<br>24–280 Vac<br>24–280 Vac|**Configuration**<br>SPST-NO<br>SPST-NO<br>SPST-NO<br>SPST-NO|**Switching Type**<br>DC switch<br>DC switch<br>Random<br>Random|**Load (Amps)**<br>15<br>8<br>10<br>10|**Catalog Number**<br>**D96115ACZ3**<br>**D96208ACZ3**<br>**D96210ACR1**<br>**D96210ACR2**|
|90–280 Vac<br>3–32 Vdc|24–280 Vac<br>24–280 Vac|SPST-NO<br>SPST-NO|Zero cross<br>Zero cross|10<br>10|**D96210ACZ1**<br>**D96210ACZ2**|
|3–32 Vdc|24–280 Vac|SPST-NC|Random|10|**D96210BCR2**|
|90–280 Vac|48–480 Vac|SPST-NO|Random|10|**D96410ACR1**|
|3–32 Vdc|48–480 Vac|SPST-NO|Random|10|**D96410ACR2**|
|90–280 Vac|48–480 Vac|SPST-NO|Zero cross|10|**D96410ACZ1**|
|3–32 Vdc|48–480 Vac|SPST-NO|Zero cross|10|**D96410ACZ2**|
|90–280 Vac<br>90–280 Vac|48–600 Vac<br>48–600 Vac|SPST-NO<br>SPST-NO|Random<br>Zero cross|10<br>10|**D96610ACR1**<br>**D96610ACZ1**|
|3–32 Vdc|48–600 Vac|SPST-NO|Zero cross|10|**D96610ACZ2**|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-129**
Control Relays and Timers
3.6
## Solid-State Relays
## **Technical Data and Specifications**
**3**
|**D96 Series**|||||||||
|---|---|---|---|---|---|---|---|---|
|**Description**|**Units**|**D96210ACZ1**|**D96210ACZ2**|**D96210ACR1**|**D96210ACR2**|**D96115ACZ3**|**D96208ACZ3**|**D96210BCR2**|
|**Output Characteristics**|||||||||
|Contact configuration||SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NC|
|Switching device<br>Current rating|A|SCR<br>10|SCR<br>10|SCR<br>10|SCR<br>10|MOSFET<br>15|MOSFET<br>8|SCR<br>10|
|Switching type<br>Maximum zero turn-on voltage (Vpk)|V|Zero cross<br>35|Zero cross<br>35|Random turn on<br>35|Random turn on<br>35|DC switching<br>NA|DC switching<br>NA|Random turn on<br>35|
|Maximum rate of rise off state voltage (DV/DT)|V/us|500|500|500|500|NA|NA|500|
|Incandescent lamp ampere rating (rms)|A|8|8|8|8|NA|NA|8|
|Motor load rating (rms)|A|4.5|4.5|4.5|4.5|NA|NA|4.5|
|Min. load current to maintain on<br>Non-repetitive surge current (1 cycle)|mA<br>A|50<br>500|50<br>500|50<br>500|50<br>500|20<br>50|20<br>35|50<br>500|
|Max. rms overload current (1 second)|A|24|24|24|24|24|17|24|
|Max. off state leakage current (rms)|mA|10|10|10|10|10|10|10|
|Typical on state voltage drop (rms)|V|1.25 AC|1.25 AC|1.25 AC|1.25 AC|1.25 DC|1.25 DC|1.25 AC|
|Max. on state voltage drop (rms)|V|1.6 AC|1.6 AC|1.6 AC|1.6 AC|1.6 DC|1.6 DC|1.6 AC|
|Max. I2t for fusing (A2)||1250|1250|1250|1250|NA|NA|1250|
|**Input Characteristics**<br>Must release voltage|V|10 AC|1 DC|10 AC|1 DC|1 DC|1 DC|1 DC|
|Typical input impedance|ohms|16–25k|Current regulator|16–25k|ACL|Current regulator|Current regulator|ACL|
|Nominal input current at 5 Vdc or 240 Vac|mA|12|16|12|16|12|12|12|
|Reverse polarity protection||NA|Yes|NA|Yes|Yes|Yes|Yes|
|**Performance Characteristics**|||||||||
|Operating time (response time)|||||||||
|ON<br>OFF|ms<br>ms|40<br>80|8.3<br>8.3|8.3<br>8.3|8.3<br>8.3|5<br>5|5<br>5|8.3<br>8.3|
|Rated insulation voltage—input to input|Vac|2500|2500|4000|4000|2500|2500|4000|
|Dielectric strength—terminal to chassis|Vac|2500|2500|2500|2500|2500|2500|2500|
|**Environment**|||||||||
|Product certifications<br>Ambient air temperature||UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|
|Storage|°C|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|
|Operating|°C|–30 to 80|–30 to 80|–30 to 80|–30 to 80|–30 to 80|–30 to 80|–30 to 80|
|Degree of protection||IP20|IP20|IP20|IP20|IP20|IP20|IP20|
|**Miscellaneous Characteristics**|||||||||
|Thermal resistance (junction to case)|°C/W|0.66|0.66|0.66|0.66|0.66|0.66|0.66|
|Integral heat sink<br>Weight|°C/W<br>g (oz)|4.0<br>127 (4.1)|4.0<br>127 (4.1)|4.0<br>127 (4.1)|4.0<br>127 (4.1)|4.0<br>127 (4.1)|4.0<br>127 (4.1)|4.0<br>127 (4.1)|
|LED—input||Green|Green|Green|Green|Green|Green|Green|
|Terminal wire capacity|AWG (mm2)|14 (2.1)|14 (2.1)|14 (2.1)|14 (2.1)|14 (2.1)|14 (2.1)|14 (2.1)|
|Terminal torque (max.)|in-lb (Nm)|7.1 (0.8)|7.1 (0.8)|7.1 (0.8)|7.1 (0.8)|7.1 (0.8)|7.1 (0.8)|7.1 (0.8)|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-130**
Control Relays and Timers
3.6
Solid-State Relays
## _**Temperature Derating Curves**_
## **8 Amp Style**
**==> picture [229 x 382] intentionally omitted <==**
**----- Start of picture text -----**<br>
35<br>30<br>25<br>20<br>15<br>10<br>8<br>5<br>1.5<br>0<br>85°<br>0° 10° 20° 30° 40° 50° 60° 70° 80° 90°<br>Max. Ambient Temperature (°C)<br>10 Amp Style<br>14<br>12<br>10<br>8<br>6<br>4<br>2<br>1.8<br>0<br>0° 10° 20° 30° 40° 50° 60° 70° 80° 90°<br>Max. Ambient Temperature (°C)<br>Load Current (amps rms)<br>Load Current (amps rms)<br>**----- End of picture text -----**<br>
## **15 Amp Style**
**==> picture [229 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
24<br>18<br>15<br>12<br>9<br>6<br>3<br>0<br>0° 10° 20° 30° 40° 50° 60° 70° 80° 90°<br>Ambient Temperature (°C)<br>Current (amps DC)<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-131**
3.6
## Control Relays and Timers
## Solid-State Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D96 Series**
**3**
**==> picture [382 x 330] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.69 0.20<br>(17.6) (5.0)<br>0.20<br>(5.0)<br>0.07<br>(1.7)<br>0.56<br>(14.2) 3.54<br>(90.0)<br>1.78 1.40 3.64<br>(45.3) (35.6) (92.4)<br>2.63<br>(66.8)<br>1.39<br>(35.2)<br>0.63 0.56<br>0.27 (16.0) 0.13 (14.3)<br>(6.9) 1.36 (3.4)<br>(34.6)<br>2.56 Max.<br>(65.0)<br>0.24<br>(6.0)<br>0.62<br>(15.8)<br>0.55<br>(14.9)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-132**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.6
Solid-State Relays
## **D99 Series—Solid-State Relays**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D93 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-121**|
|D96 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-128**|
|D99 Series||
|Product Selection . . . . . . . . . . . . . . . . . . . . .<br>Technical Data and Specifications . . . . . . . . . .|**V7-T3-134**<br>**V7-T3-135**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-138**|
**3**
## **D99 Series**
## **Product Description**
Eaton’s D99 series of solidstate relays is a line of heavy-duty industrial relays with an integrated heat sink. The attached metal hardware can be used for DIN rail or panel mounting.
Models are available in a variety of input voltages in 10A, 25A and 40A sizes.
## **Application Description**
A solid-state relay (SSR) can perform many applications that an electromechanical relay can perform. The SSR differs in that it has no moving mechanical parts within it and has some distinct advantages over an electromechanical relay.
When used correctly in the intended application, the SSR provides a high degree of reliability, a long service life, significantly reduced electromagnetic interference, fast response and high vibration resistance.
## **Standards and Certifications**
## **Features and Benefits**
- All solid-state circuitry has no moving parts to wear
- UL/cUL listed—UL 508
- CSA certified
- Integral heat sink ● CE marked eliminates the need for ● RoHS compliant added accessories and installation
- Flexible mounting allows DIN rail or panel mounting without additional hardware or tools
- Isolated input and output terminals protect the system from electrical noise
- Internal snubber circuitry protects the SSR from transients
Applications for the SSR typically include equipment that requires high cycling rates, low acoustical or electrical noise, or high vibration resistance. Some examples are medical equipment, heating/cooling equipment, lighting control and pumps/compressors, among others.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-133**
3.6
## Control Relays and Timers
Solid-State Relays
## **Product Selection**
**3**
## **D99210ACZ1**
## **D99 Series**
|**D99 Series**||||||
|---|---|---|---|---|---|
|||**Contact**||**Rated Current**||
|**Input Voltage**<br>90–280 Vac<br>3–32 Vdc<br>90–280 Vac|**Output Voltage**<br>24–280 Vac<br>24–280 Vac<br>24–280 Vac|**Configuration**<br>SPST-NO<br>SPST-NO<br>SPST-NO|**Switching Type**<br>Zero cross<br>Zero cross<br>Zero cross|**Load (Amps)**<br>10<br>10<br>25|**Catalog Number**<br>**D99210ACZ1**<br>**D99210ACZ2**<br>**D99225ACZ1**|
|3–32 Vdc|24–280 Vac|SPST-NO|Zero cross|25|**D99225ACZ2**|
|90–280 Vac<br>3–32 Vdc|24–280 Vac<br>24–280 Vac|SPST-NO<br>SPST-NO|Zero cross<br>Zero cross|40<br>40|**D99240ACZ1**<br>**D99240ACZ2**|
|90–280 Vac|48–600 Vac|SPST-NO|Zero cross|10|**D99610ACZ1**|
|3–32 Vdc|48–600 Vac|SPST-NO|Zero cross|10|**D99610ACZ2**|
|90–280 Vac|48–600 Vac|SPST-NO|Zero cross|25|**D99625ACZ1**|
|3–32 Vdc|48–600 Vac|SPST-NO|Zero cross|25|**D99625ACZ2**|
|90–280 Vac|48–600 Vac|SPST-NO|Zero cross|40|**D99640ACZ1**|
|3–32 Vdc|48–600 Vac|SPST-NO|Zero cross|40|**D99640ACZ2**|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-134**
Control Relays and Timers
3.6
Solid-State Relays
## **Technical Data and Specifications**
|**D99 Series**||||||||
|---|---|---|---|---|---|---|---|
|**Description**|**Units**|**D99210ACZ1**|**D99210ACZ2**|**D99225ACZ1**|**D99225ACZ2**|**D99240ACZ1**|**D99240ACZ2**|
|**Output Characteristics**||||||||
|Contact configuration||SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NO|
|Switching device<br>Current rating|A|SCR<br>10|SCR<br>10|SCR<br>25|SCR<br>25|SCR<br>40|SCR<br>40|
|Switching type<br>Maximum zero turn-on voltage (Vpk)|V|Zero cross<br>35|Zero cross<br>35|Zero cross<br>35|Zero cross<br>35|Zero cross<br>35|Zero cross<br>35|
|Maximum rate of rise off state voltage (DV/DT)|V/us|500|200|500|500|500|500|
|Incandescent lamp ampere rating (rms)|A|8|8|16|16|20|20|
|Motor load rating (rms)|A|4.5|4.5|8|8|14|14|
|Min. load current to maintain on|mA|50|50|120|120|250|250|
|Non-repetitive surge current (1 cycle)|A|83|83|800|800|800|800|
|Max. rms overload current (1 second)|A|24|24|40|40|100|100|
|Max. off state leakage current (rms)|mA|10|10|10|10|10|10|
|Typical on state voltage drop (rms)|Vac|1.25|1.25|1.35|1.35|1.6|1.6|
|Max. on state voltage drop (rms)|Vac|1.6|1.6|1.8|1.8|1.6|1.6|
|Max. I2t for fusing (A2)||83|83|3700|3700|3700|83|
|**Input Characteristics**<br>Must release voltage|V|10 AC|1 DC|10 AC|1 DC|10 AC|1 DC|
|Typical input impedance|ohms|16–25k|Current regulator|16–25k|Current regulator|13k|Current regulator|
|Nominal input current at 5 Vdc or 240 Vac|mA|12|12|12|12|16|16|
|Reverse polarity protection||NA|Yes|NA|Yes|NA|Yes|
|**Performance Characteristics**||||||||
|Operating time (response time)||||||||
|ON<br>OFF|ms<br>ms|8.3<br>8.3|8.3<br>8.3|8.3<br>8.3|8.3<br>8.3|8.3<br>8.3|10<br>10|
|Rated insulation voltage—input to input|Vac|4000|4000|4000|4000|4000|4000|
|Dielectric strength—terminal to chassis|Vac|4000|4000|4000|4000|4000|4000|
|**Environment**||||||||
|Product certifications<br>Ambient air temperature||UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|
|Storage|°C|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|
|Operating|°C|–30 to 80|–30 to 80|–30 to 80|–30 to 80|–30 to 80|–30 to 80|
|Degree of protection||IP20|IP20|IP20|IP20|IP20|IP20|
|**Miscellaneous Characteristics**||||||||
|Thermal resistance (junction to case)|°C/W|1.5|1.5|1.5|0.43|1.5|0.43|
|Integral heat sink<br>Weight|°C/W<br>g (oz)|2.2<br>320 (11.3)|2.2<br>320 (11.3)|2.2<br>320 (11.3)|2.2<br>326 (11.5)|2.2<br>320 (11.3)|2.2<br>332 (11.7)|
|LED—input||Green|Green|Green|Green|Green|Green|
|Terminal wire capacity|AWG (mm2)|8 (10)|8 (10)|8 (10)|8 (10)|8 (10)|8 (10)|
|Terminal torque (max.)|in-lb (Nm)|12.5 (1.4)|12.5 (1.4)|12.5 (1.4)|12.5 (1.4)|12.5 (1.4)|12.5 (1.4)|
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-135**
Control Relays and Timers
3.6
**3**
## Solid-State Relays
## **D99 Series, continued**
|**D99 Series, continued**||||||||
|---|---|---|---|---|---|---|---|
|**Description**|**Units**|**D99610ACZ1**|**D99610ACZ2**|**D99625ACZ1**|**D99625ACZ2**|**D99640ACZ1**|**D99640ACZ2**|
|**Output Characteristics**||||||||
|Contact configuration||SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NO|SPST-NO|
|Switching device||SCR|SCR|SCR|SCR|SCR|SCR|
|Current rating<br>Switching type|A|10<br>Zero cross|10<br>Zero cross|25<br>Zero cross|10<br>Zero cross|40<br>Zero cross|40<br>Zero cross|
|Maximum zero turn-on voltage (Vpk)|V|35|35|35|35|35|35|
|Maximum rate of rise off state voltage (DV/DT)|V/us|200|200|700|700|500|500|
|Incandescent lamp ampere rating (rms)|A|8|8|16|16|20|20|
|Motor load rating (rms)|A|4.5|4.5|8|8|14|14|
|Min. load current to maintain on|mA|80|80|250|250|250|250|
|Non-repetitive surge current (1 cycle)<br>Max. rms overload current (1 second)|A<br>A|83<br>24|83<br>24|1000<br>50|1000<br>50|800<br>100|800<br>100|
|Max. off state leakage current (rms)|mA|10|10|10|10|10|10|
|Typical on state voltage drop (rms)|Vac|1.25|1.25|1.35|1.35|1.6|1.6|
|Max. on state voltage drop (rms)|Vac|1.6|1.6|1.6|1.6|1.6|1.6|
|Max. I2t for fusing (A2)<br>**Input Characteristics**||83|83|1700|1700|3700|3700|
|Must release voltage|V|10 AC|1 DC|10 AC|1 DC|10 AC|1 DC|
|Typical input impedance|ohms|16–25k|Current regulator|16–25k|Current regulator|13k|Current regulator|
|Nominal input current at 5 Vdc or 240 Vac|mA|12|16|12|16|16|16|
|Reverse polarity protection||NA|Yes|NA|Yes|NA|Yes|
|**Performance Characteristics**||||||||
|Operating time (response time)<br>ON|ms|8.33|8.3|8.33|8.3|10|10|
|OFF|ms|8.33|8.3|8.33|8.3|10|10|
|Rated insulation voltage—input to input|Vac|4000|4000|4000|4000|4000|4000|
|Dielectric strength—terminal to chassis|Vac|4000|4000|4000|4000|4000|4000|
|**Environment**||||||||
|Product certifications||UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|UL, CSA, CE|
|Ambient air temperature<br>Storage|°C|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|–40 to 100|
|Operating|°C|–30 to 80|–30 to 80|–30 to 80|–30 to 80|–30 to 80|–30 to 80|
|Degree of protection||IP20|IP20|IP20|IP20|IP20|IP20|
|**Miscellaneous Characteristics**||||||||
|Thermal resistance (junction to case)<br>Integral heat sink|°C/W<br>°C/W|1.8<br>2.2|1.8<br>2.2|0.43<br>2.2|0.43<br>2.2|0.43<br>2.2|0.43<br>2.2|
|Weight<br>LED—input|g (oz)|320 (11.3)<br>Green|321 (11.3)<br>Green|326 (11.5)<br>Green|326 (11.5)<br>Green|332 (11.7)<br>Green|332 (11.7)<br>Green|
|Terminal wire capacity|AWG (mm2)|8 (10)|9 (10)|8 (10)|8 (10)|8 (10)|8 (10)|
|Terminal torque (max.)|in-lb (Nm)|12.5 (1.4)|12.5 (1.4)|12.5 (1.4)|12.5 (1.4)|12.5 (1.4)|12.5 (1.4)|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-136**
Control Relays and Timers
3.6
Solid-State Relays
## _**Temperature Derating Curves**_
## **10 Amp Styles**
**==> picture [229 x 348] intentionally omitted <==**
**----- Start of picture text -----**<br>
12<br>10<br>8<br>6<br>4<br>2<br>0<br>0° 10° 20° 30° 40° 50° 60° 70° 80° 90°<br>Ambient Temperature (°C)<br>25 Amp Styles<br>25<br>20<br>15<br>10<br>5<br>0<br>0° 10° 20° 30° 40° 50° 60° 70° 80° 90°<br>Ambient Temperature (°C)<br>Current in amps<br>Current in amps<br>**----- End of picture text -----**<br>
## **40 Amp Styles**
**==> picture [229 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
40<br>30<br>25<br>20<br>15<br>10<br>0<br>0° 10° 20° 30° 40° 50° 60° 70° 80° 90°<br>Ambient Temperature (°C)<br>Current in amps<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-137**
Control Relays and Timers
3.6
Solid-State Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D99 Series**
**==> picture [411 x 382] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>3<br>3<br>3.20 1.20<br>3 (80.0) (30.0)<br>3<br>1.20<br>3 (30.0)<br>3<br>3 (1.20)0.05<br>4.20<br>(107.0)<br>3<br>3<br>3<br>3 3.10<br>(77.5)<br>3 0.20 (5.0)Radius 0.20 (5.0)Radius<br>3<br>0.50 (11.9)<br>3<br>3 3.70<br>(92.9)<br>3 4.00<br>(102.0)<br>3<br>1<br>–<br>+ Input Output<br>2<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-138**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.7
Machine Tool Relays
**==> picture [60 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Machine Tool Relays<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||**3**|
|---|---|---|
|**_Description_**|**_Page_**||
|Machine Tool Relays||**3**|
|D15 Series—Freedom 600V Multipole . . . . . . .<br>BF/BFD Series—Fixed Contact|**V7-T3-140**|**3**|
|Industrial Control . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-145**||
|AR/ARD Series—Convertible Contact||**3**|
|Industrial Control . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-151**||
|D26 Series—Type M, 600 Vac Multipole||**3**|
|with Convertible Contacts . . . . . . . . . . . . . . .|**V7-T3-156**||
|D26 Series—Type M, DC Multipole||**3**|
|with Convertible Contacts . . . . . . . . . . . . . . .|**V7-T3-161**||
## **Product Overview**
Eaton’s machine tool relay offering includes a variety of NEMA type relays. Included in this are open style relays and relays with convertible or side-mount contacts. Also included in this family are a variety of accessories to match the application, including suppressors, timing contacts and enclosures. The relay coils are available in a variety of line and control level voltages.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-139**
3.7
Machine Tool Relays
## Control Relays and Timers
**3**
## **D15 Series—Freedom 600V Multipole**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D15 Series—Freedom 600V Multipole||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-141**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-142**|
|Technical Data and Specifications . . . . . . . . . .|**V7-T3-143**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-144**|
|BF/BFD Series—Fixed Contact||
|Industrial Control . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-145**|
|AR/ARD Series—Convertible Contact||
|Industrial Control . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-151**|
|D26 Series—Type M, 600 Vac Multipole||
|with Convertible Contacts . . . . . . . . . . . . . . . . .|**V7-T3-156**|
|D26 Series—Type M, DC Multipole||
|with Convertible Contacts . . . . . . . . . . . . . . . . .|**V7-T3-161**|
## **D15 Series—Freedom 600V Multipole**
## **Product Description**
Contact poles on the D15 relay are of the fixed design and are not convertible. The basic four-pole relay will accept a front-mounted contact pole deck and/or sidemounted contact blocks (one per side). In addition, a sidemounted solid-state timer or a front-mounted pneumatic timer can be added to the relay. Only one frontmounted attachment can be added to the basic relay.
## **Application Description**
Side-mounted contact blocks can be used to provide additional poles in applications where a pneumatic timer is installed on the front of the relay. They can also be used where panel depth is restricted.
The maximum number of contacts recommended per relay is eight, six of which can be NC. When a pneumatic timer is used, the maximum recommended number of NC contacts is three.
Relays with DC coils are supplied with a coil clearing NC contact mounted on the side of the relay.
## **Features and Benefits**
- Contact pole terminals have captive, backed-out, self-lifting pressure plates with ± screws—reduced wiring time
- 600V, 10A continuous thermal current
- State indicator visually shows relay ON or OFF status
- All terminals are shrouded or “finger-proofed” to reduce possibility of electrical shock
- Relay base has mounting holes on 35 x 60 mm centers, permitting direct replacement of competitive relays
- Designed to meet or exceed UL, NEMA, IEC, CSA, VDE, BS and other international standards
- Relay also mounts on 35 mm DIN rail as standard
- Magnet coil has three terminals, permitting either top or diagonal wiring— easy to replace European **Standards and Certifications** or U.S. relays without ● UL changing wiring layout ● CSA certified ho ● CE marked @ c ~~e~~
## **Standards and Certifications**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-140**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.7
Machine Tool Relays
## **Product Selection**
## _**When Ordering, Specify**_
Catalog number and magnet coil code letter. Example: For a four-pole relay having 4NO contacts with a 120V 60 Hz coil, order Catalog Number D15CR40 **A** B.
## **Factory-Assembled Multipole Relays**
**3**
||**Number of**|**Type of Contacts**||**Open Type**|
|---|---|---|---|---|
||**Poles**|**NO**|**NC**|**Catalog Number**1|
|**D15CR40_B**|4|4|0|**D15CR40_B**|
|||3|1|**D15CR31_B**|
|||2|2|**D15CR22_B**|
|||1<br>~~OS~~|3<br>~~OS~~|**D15CR13_B**<br>~~OS~~|
|||0|4|**D15CR04_B**|
|**D15CR60_B**|6|6|0|**D15CR60_B**|
|gana,<br>288|(four-pole relay with two-pole<br>front-mounted deck)|5<br>1<br>**D15CR51_B**<br>4<br>2<br>**D15CR42_B**<br>~~OO~~|||
|||3|3|**D15CR33_B**|
|S888||2<br>4<br>**D15CR24_B**<br>1<br>5<br>**D15CR15_B**2<br>~~OO~~|||
|||0|6|**D15CR06_B**2|
|**D15CR80_B**|8|8|0|**D15CR80_B**|
||(four-pole relay with four-pole<br>front-mounted deck)|7|1|**D15CR71_B**|
|||6|2|**D15CR62_B**|
|||5|3|**D15CR53_B**|
|||4|4|**D15CR44_B**|
|||3|5|**D15CR35_B**2|
|||2|6|**D15CR26_B**2|
## **Additional Contact Poles**
## **Magnet Coil Selection**
||**Catalog**|**AC Coils**|**Code**|**DC Coils**|**Code**|
|---|---|---|---|---|---|
|**Description**|**Number**|**Volts and Hertz**|**Suffix**|**Volts**|**Suffix**|
|**Front Contact Pole Deck**||120/60 or 110/50|**A**|12|**R1**|
|1NO-1NC|**C320KGT3**|240/60 or 220/50|**B**|24|**T1**|
|2NO<br>2NC|**C320KGT4**<br>**C320KGT5**|480/60 or 440/50<br>600/60 or 550/50|**C**<br>**D**|48<br>120|**W1**<br>**A1**|
|1NO (early closing)–1NC (late opening)|**C320KGT7**|208/60|**E**|||
|4NO|**C320KGT13**|277/60|**H**|||
|3NO-1NC|**C320KGT14**|208–240/60|**J**|||
|2NO-2NC|**C320KGT15**|24/60|**T**|||
|1NO-3NC|**C320KGT16**|||||
|4NC<br>**Side-Mounted Contact Blocks**|**C320KGT17**|||||
|1NO-1NC|**C320KGS3**|||||
|2NO|**C320KGS4**|||||
|2NC|**C320KGS5**|||||
|1NO (early closing)–1NC (late opening)|**C320KGS7**|||||
## _**Notes**_
> 1 Underscore indicates missing code suffix for magnet coil—see Magnet Coil Selection table above.
- 2 Not all suffix codes available: consult Customer Support Center.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-141**
Control Relays and Timers
3.7
## Machine Tool Relays
## **Accessories**
**3**
## **Pneumatic Timer Attachment**
## **C320 Pneumatic Timer Attachment**
||||**Catalog**||
|---|---|---|---|---|
|**Timing Range**<br>0.1 to 30 seconds|||**Number**<br>**C320TP1**||
|10 to 180 seconds|||**C320TP2**||
|**Maximum Ampere Ratings**||**Maximum Ampere Ratings**|||
||**Volts AC**||||
|**Description**|**120**|**240**|**480**|**600**|
|Make|30|15|7.5|6|
|Break|3|1.5|0.75|0.6|
Attachment mounts on top of timed contacts—circuits in any Freedom Series relay each pole must be the same (top-mounted auxiliary polarity. Units are convertible contacts can not be installed from OFF to ON delay or on device when timer is vice-versa. used). Timer unit has DPST
## **Finger Protection Shields**
||**Catalog**|
|---|---|
|**Application**|**Number**|
|D15|**C320LS1**|
Snap-on shields for both Finger Protection. Prevents contactors and starters accidental contact with line/ provide IEC Type IP20 load terminals.
## **Adhesive Dust Cover**
|**Description**|**Catalog**<br>**Number**|
|---|---|
|25 to a package|**C320DSTCVR**|
These adhesive stickers applied to side opening come 25 to a package and where auxiliaries are not provide extra protection from installed and provide extra contaminants when applied protection from metal filings to the sides of Freedom D15. and other debris. Adhesive covers are easily
## **Solid-State ON DELAY Timer**[1]
**Solid-State Timer**
|**Timing Range**<br>0.1 to 1.0 seconds<br>1 to 30 seconds<br>30 to 300 seconds<br>5 to 30 minutes|**Catalog**<br>**Number**234<br>**C320TDN1_**<br>**C320TDN30_**<br>**C320TDN300_**<br>**C320TDN3000_**|
|---|---|
This timer is designed to be **wired in series with the**
## **Metal Mounting Plate**
## **C32MP1**
||**Catalog**|
|---|---|
|**Description**<br>Metal mounting plate|**Number**<br>**C321MP1**|
Fits all D15 multipole relays.
## **Mounting Channel (DIN Rail)**
|**Mounting Channel (DIN Rail)**|**Mounting Channel (DIN Rail)**|
|---|---|
|**Mounting Channel (DIN Rail)**<br>**DIN Rail**|**Mounting Channel (DIN Rail)**|
|Designed for DIN rail<br>mounting of Freedom<br>Series relays.<br>**Description**<br>**Catalog**<br>**Number**<br>1 meter length<br>**XBANS3575P**<br>~~ae~~||
|**Transient Suppressor Kits**<br>**C320TS2**||
|**Description**<br>**Coil Voltage**<br>**50/60 Hz**5|**Catalog**<br>**Number**|
|Transient<br>24/120V|**C320TS1**|
|Suppressor<br>208/240V<br>a<br>||**C320TS2**|
|277/480V<br>a<br>||**C320TS3**|
These kits limit high voltage transients produced in the control circuit when power is removed from the contactor or starter coil. There are three separate suppressors for use on 24–120V, 208–240V or 27– 480V coils respectively.
These devices mount directly to the coil terminals.
## _**Notes**_
> 1 Side mounted on Freedom Series NEMA 00–2, D15, IECA-K and C25D, C25E and C25F frame.
- 2 Add operating voltage suffix to catalog number; **A** = 120V, **B** = 240V, **E** = 208V.
- 3 Rated 0.5 ampere pilot duty—not to be used on larger contactors.
- 4 Terminal connections are quick connects only. Two per side.
- 5 Suppressor is compatible with coil voltages/ranges as shown, both 50 and 60 Hz.
**load** (typically a coil). When the START button is pushed (power applied to timer), the ON delay timing function starts. At the completion of the set timing period, timer and series wired load will both be energized.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-142**
Control Relays and Timers
Machine Tool Relays
## 3.7
|**C320DC**|**AC/DC Interface Module—**<br>**Controller Coil Voltage Ranges**|**AC/DC Interface Module—**<br>**Controller Coil Voltage Ranges**|**Controller Coil Voltage Ranges**|
|---|---|---|---|
||**Controller Catalog**|**Controller**|**Coil Range**|
||**Number Prefix**|**Size or Rating**|**Volts AC**|
||AE16, AE17, AE56,|A–F|24–240|
||AE57, CE15, CE55|G–K|48–240|
|||L–N|110–240|
||AN16, AN56,|00–0|24–240|
||CN15, CN55|1–2|48–240|
|||3|110–240|
||CN35|10–30A|24–240|
|||60A|48–240|
|||100A|110–240|
The Catalog Number C320DC Interface Module is an optically isolated solid-state switch that provides a means of operating AC coils with a 24 Vdc control signal. It acts as a space-saving interposing relay that can switch a specified 50/60 Hz AC source to the contactor or starter coil.
provisions for DIN rail mounting.
The module will operate coils within the voltage ranges shown in the table to the left.
Design Characteristics
- DC input: 24V ±10% at mA nominal
- AC operating voltage: 24–240 Vac ±10% 50/60 Hz
The module may be directly 24–240 Vac ±10% attached to the coil terminals 50/60 Hz of any Freedom Series contactor or starter—NEMA ● AC current rating: Sizes 00–3, D15, IEC Sizes 10A make (inrush), 1A break (sealed) A–N and lighting contactors 10–100A. It also has
**3**
## **Typical Application—Solid-State Switch**
**==> picture [153 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
Contactor Coil<br>24 Vdc<br>Input<br>Observe 24–240 Vac<br>Polarity on 50/60 Hz<br>Module<br>oe<br>**----- End of picture text -----**<br>
## **Technical Data and Specifications**
## **Contact Ratings—NEMA A600**
|**Contact Ratings—NEMA A600**|**Contact Ratings—NEMA A600**||
|---|---|---|
|**Continuous Thermal Rating: 10A**|||
|**AC Volts**|**Make**|**Break**|
|120|60|6.0|
|240|30|3.0|
|480|15|1.5|
|600|12|1.2|
## **Example of Terminal Marking with 2NO and 2NC Contacts**
**==> picture [166 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
Location<br>Status<br>(NO or NC)<br>13 21 31 43<br>eee<br>14 22 32 44<br>**----- End of picture text -----**<br>
## **Contact Ratings—NEMA P300**
|**Contact Ratings—NEMA P300**|**Contact Ratings—NEMA P300**|
|---|---|
|**Continuous Thermal Rating: 5A**||
|**DC Volts**|**Make/Break Amperes**|
|125|1.1|
|250|0.55|
## **Magnet Coil Data**
|**AC**|**Pickup**||**Sealed**||
|---|---|---|---|---|
|**Voltage**|**VA**|**Watts**|**VA**|**Watts**|
|12–600V|80|49|7.5|2.4|
|**DC**|**Pickup**||**Sealed**||
|**Voltage**|**Amps**|**Watts**|**VA**|**Watts**|
|12|6.4|76.8|0.28|3.36|
|24|3.2|76.8|0.14|3.36|
|48|1.6|76.8|0.07|3.36|
|120|0.64|76.8|0.028|3.36|
Relay terminals are identified by a two-digit number in accordance with International Standards approved by CENELEC (European Committee for Electrotechnical Standardization). The number is marked on the relay and is used to identify location and status of the contacts.
The first digit indicates the location of the contact on the relay. The numbering begins with 1 and continues without a break from left to right.
The second digit indicates the status of the contacts (NO or NC). Terminal marking 1 and 2 mean NC and 3 and 4 mean NO.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-143**
Control Relays and Timers
3.7
Machine Tool Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D15 Four-Pole Relay**
**3**
**==> picture [208 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.54 0.54<br>(13.7) (13.7)<br>1.8<br>(45.7)<br>C<br>Frt. Side 2.96<br>2.36 Mtd. Mtd. (75.2)<br>(59.9) Acc. Blk.<br>1.36<br>(34.5) Optional Additional<br>Contact Poles<br>Mtg. Holes for or Accessories<br>M4 or #8 Screws<br>**----- End of picture text -----**<br>
## **D15 Six- and Eight-Pole Relays**
**==> picture [208 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.54 0.54<br>(13.7) (13.7)<br>1.8<br>(45.7)<br>4.66<br>(118.4)<br>Frt. Side 2.96<br>2.36 Mtd. Mtd. (75.2)<br>(59.9) Acc. Blk.<br>1.36<br>(34.5) Optional Additional<br>Contact Poles<br>Mtg. Holes for or Accessories<br>M4 or #8 Screws<br>**----- End of picture text -----**<br>
## **Dimensions and Shipping Weights**
|**Description**|**Dimension C**|**Shipping Weights**<br>**Lbs (kg)**|
|---|---|---|
|Relay only<br>Relay with timer attachment|3.30 (83.8)<br>5.55 (141.0)|1.3 (0.6)<br>1.5 (0.7)|
|Relay with front contact pole deck|4.66 (118.4)|1.7 (0.8)|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-144**
CA08100008E—April 2012 www.eaton.com
3.7
Machine Tool Relays
## Control Relays and Timers
## **BF/BFD Series—Fixed Contact Industrial Control**
## **Contents**
**==> picture [244 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Page|
|D15 Series—Freedom 600V Multipole. . . . . . . . . .|V7-T3-140|
|BF/BFD Series—Fixed Contact Industrial|
|Control|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-146|
|Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-148|
|Technical Data and Specifications . . . . . . . . . .|V7-T3-149|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-150|
|AR/ARD Series—Convertible Contact|
|Industrial Control . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-151|
|D26 Series—Type M, 600 Vac Multipole|
|with Convertible Contacts . . . . . . . . . . . . . . . . . .|V7-T3-156|
|D26 Series—Type M, DC Multipole|
|with Convertible Contacts . . . . . . . . . . . . . . . . . .|V7-T3-161|
**----- End of picture text -----**<br>
**3**
## **BF/BFD Series—Fixed Contact Industrial Control**
## **Product Description**
Type BF is AC operated, 300V maximum, and the BFD is DC operated, 250V. Fixed contact relays are available in any combination of NO and NC from two to 12 poles. BF and BFD relays have captive clamp terminals fully accessible from the front, a molded coil with low operating temperature and silver alloy contacts suitable for low voltage circuits.
## **Features and Benefits**
## _**Wiring to Relay**_
- In parallel with coil—one timed and up to 12 instantaneous contacts, or
- In series with coil—up to 12 timed contacts in one relay
## _**Permanent Magnet Latch**_
- Field mountable on Catalog Number BF; factory installed on BFD
## **Standards and Certifications**
- UL recognized, UL File No. E19223 (AC relays only)
- ● CSA certified, File No. LR39402-6, LR28548-10, 11 (AC and DC relays)
- Latch coil continuously rated
- Latch plunger adjustable for optimum performance
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-145**
3.7
## Control Relays and Timers
## Machine Tool Relays
## **Product Selection**
## _**When Ordering, Specify**_
- Catalog number of basic relay
**3**
- If a coil voltage other than listed is required, select the suffix code from the Coil Voltage table and substitute it for the last letter in the catalog number. Example: BF80 **V** for a 110/60 AC coil
**Complete Relay—Type BF and BFD, Two-, Three-, Four- and Six-Pole**[1]
## **Type BF**
||||||||**BF 300 Vac Basic Relays**|**BFD 250 Vdc Basic**<br>**Relays**|
|---|---|---|---|---|---|---|---|---|
||{||||**Type of Contact**||**120/60, 110/50 AC Coil**|**120 DC Coil**|
|79||owe||**Number**<br>**of Poles**|**NO (Form A)**|**NC (Form B)**|**Catalog**<br>**Number**|**Catalog**<br>**Number**|
||Vw<br>Wi||bea|2|2<br>1<br>~~I.~~|0<br>1|**BF20F**<br>**BF11F**|**BFD20S**<br>**BFD11S**|
||||||0|2|**BF02F**|**BFD02S**|
|**Type BFD**||||3|3<br>2|0<br>1|**BF30F**<br>**BF21F**|**BFD30S**<br>**BFD21S**2|
|ip /|Pe|a|q||1<br>0|2<br>3|**BF12F**<br>**BF03F**|**BFD12S**<br>**BFD03S**|
|||||4|4|0|**BF40F**|**BFD40S**|
|—|||Ag||3<br>1<br>~~qin~~||**BF31F**|**BFD31S**|
||Tory||||2|2|**BF22F**|**BFD22S**|
||||||1<br>0|3<br>4|**BF13F**<br>**BF04F**|**BFD13S**<br>**BFD04S**|
|||||6|6|0|**BF60F**|**BFD60S**|
||||||5|1|**BF51F**|**BFD51S**|
||||||4|2|**BF42F**|**BFD42S**|
||||||3|3|**BF33F**|**BFD33S**|
||||||2|4|**BF24F**|**BFD24S**|
||||||0|6|**BF06F**|**BFD06S**|
## **Coil Voltage**
|**BF Coils**<br>**Volts AC**|**Hz**|**Suffix Code**|**BFD Coils**<br>**Volts DC**|**Suffix Code**|
|---|---|---|---|---|
|12<br>~~eee~~|60<br>~~eee~~|**H**<br>~~eee~~|6<br>~~eee~~|**C**<br>~~eee~~|
|24|60|**I**|12|**D**|
|48|60|**J**|24|**L**|
|110<br>110/120|60<br>50/60|**V**<br>**F**|38<br>48|**N**<br>**M**|
|208|60|**K**|72|**E**|
|220/240|50/60|**G**|95|**B**|
|440|60|**C**|120|**S**|
||||130|**U**|
||||240|**T**|
## _**Notes**_
- 1 Relays listed above with equal number of NO and NC contact poles are specially priced—1NO and 1NC pole are supplied at no additional charge.
- 2 Consult Customer Support Center for availability.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-146**
Control Relays and Timers
3.7
Machine Tool Relays
## _**When Ordering, Specify**_
- Catalog number of basic relay
- If a coil voltage other than listed is required, select the suffix code from the Coil Voltage table and substitute it for the last letter in the catalog number. Example: BF80 **V** for a 110/60 AC coil
## **Complete Relay—Type BF and BFD, Eight-, 10- and 12-Pole**[1]
|||||||**Complete Relay—Type BF and BFD, Eight-, 10- and 12-Pole**|**Complete Relay—Type BF and BFD, Eight-, 10- and 12-Pole**|**Complete Relay—Type BF and BFD, Eight-, 10- and 12-Pole**|**Complete Relay—Type BF and BFD, Eight-, 10- and 12-Pole**[1]||
|---|---|---|---|---|---|---|---|---|---|---|
|**Type BF**||||||**Complete Relay—Type BF and BFD, Eight-, 10- and 12-Pole**|**Complete Relay—Type BF and BFD, Eight-, 10- and 12-Pole**|**Complete Relay—Type BF and BFD, Eight-, 10- and 12-Pole**|**Complete Relay—Type BF and BFD, Eight-, 10- and 12-Pole**[1]||
|||||||||||**BFD 250 Vdc Basic**|
||er<br>;||||||||**BF 300 Vac Basic Relays**|**Relays**|
||z..<br>.||||||**Type of Contact**||**120/60, 110/50 AC Coil**|**120 DC Coil**|
|||||||**Number**|||**Catalog**|**Catalog**|
|=a:||i<br>i|i)|||ki|**of Poles**<br>**NO (Form A)**<br>**NC (Form B)**<br>**Number**<br>**Number**<br>8<br>8<br>0<br>**BF80F**<br>**BFD80S**<br>~~—_—_—_—————————————————————————_—__=_=~~|||||
|sil.|ay||cure<br>i||||7<br>1<br>**BF71F**<br>**BFD71S**<br>~~ee~~||||
||||||||6|2|**BF62F**|**BFD62S**|
|**Type BFD**|||||||5|3|**BF53F**|**BFD53S**|
||||||||4|4|**BF44F**|**BFD44S**|
|TATE||Fara|||||0<br>8<br>**BF08F**<br>**BFD08S**<br> ~~a~~|||||
|||||||10|10|0|**BF100F**|**BFD100S**|
||||||||8|2|**BF82F**|**BFD82S**2|
||||||||7|3|**BF73F**2|**BFD73S**|
|WYAG||ae)<br>a|||||6|4|**BF64F**|**BFD64S**|
||||||||5|5|**BF55F**|**BFD55S**2|
||||||||4|6|**BF46F**|**BFD46S**|
||||||||2|8|**BF28F**|**BFD28S**|
|||||||12|12|0|**BF120F**|**BFD120S**|
||||||||8|4|**BF84F**|**BFD84S**|
||||||||7|5|**BF75F**|**BFD75S**|
||||||||6|6|**BF66F**|**BFD66S**|
||||||||5|7|**BF57F**|**BFD57S**|
||||||||4|8|**BF48F**|**BFD48S**|
**3**
## **Coil Voltage**
|**BF Coils**|||**BFD Coils**||
|---|---|---|---|---|
|**Volts AC**|**Hz**|**Suffix Code**|**Volts DC**|**Suffix Code**|
|12|60|**H**|6|**C**|
|24|60|**I**|12|**D**|
|48|60|**J**|24|**L**|
|110|60|**V**|38|**N**|
|110/120|50/60|**F**|48|**M**|
|208|60|**K**|72|**E**|
|220/240|50/60|**G**|95|**B**|
|440|60|**C**|120|**S**|
||||130|**U**|
||||240|**T**|
## _**Notes**_
- 1 Relays listed above with equal number of NO and NC contact poles are specially priced—1NO and 1NC pole are supplied at no additional charge.
- 2 Consult Customer Support Center for availability.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-147**
Control Relays and Timers
3.7
## Machine Tool Relays
**3**
## **Permanent Magnet Latch, Relay Mounted**
## **Permanent Magnet Latch**
|**Coil**<br>**Catalog**|
|---|
|**Volts**<br>**Coil Hz**<br>**Number**<br>**AC Relays**<br>~~ES~~|
|24<br>60<br>**BFMLI**2|
|48<br>60<br>**BFMLJ**2<br>110/120<br>50/60<br>**BFMLF**<br>~~a~~|
|220/240<br>50/60<br>**BFMLG**<br>**DC Relays**<br>24<br>—<br>**BFMLL**<br>48<br>—<br>**BFMLM**<br>~~TO~~<br>~~HO~~<br>~~.?:CSC SS :*—~C~~<br>CIinx)|
|120<br>—<br>**BFMLS**|
|240<br>—<br>**BFMLT**|
## **Options**
## **FASTON Push-On Terminals**
## **NEMA 1 Enclosure for Relay Types**
**Code Catalog Code Catalog Description Letter Number Description Letter Number** ~~eee~~ Insert letter **F** after relay type designation in listed catalog **F —** ~~SS~~ BF, AR—all poles **— 4977D40G04** number. Example: BF **F** 20F or BFD **F** 20S
|**Code**<br>**Catalog**|
|---|
|**Description**<br>**Letter**<br>**Number**<br>BF, AR—all poles<br>**—**<br>**4977D40G04**<br>BFD—4–8 poles<br>**—**<br>**4977D40G04**<br>ARD—4–8 poles<br>**—**<br>**4977D40G04**<br>~~SS~~|
## _**Notes**_
## **Overlapping Contacts**
|**Description**<br>~~eV~~|**Code**<br>**Letter**<br>~~eV~~|**Catalog**<br>**Number**<br>~~eV~~|
|---|---|---|
|NO contact closes before corresponding NC contact opens—<br>supplied as NO/NC set(s). Insert letter**A**after relay|**A**|**—**|
|type designation in listed catalog number. Example: BF**A**22F<br>or BFD**A**F22S|||
> 1 For panel mount, add Suffix **F** .
- 2 Consult Customer Support Center for availability.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-148**
Control Relays and Timers
3.7
Machine Tool Relays
## **Technical Data and Specifications**
## **General Specifications**
## **BF Relay Electrical Ratings—NEMA A300**
||**Maximum Current**|**Maximum Current**||**Maximum VA**||||
|---|---|---|---|---|---|---|---|
|**Volts**|**Cont.**|**Make**|**Break**|**Make**|**Break**|||
|120|10|60|6|7200|720|||
|240|10|30|3|7200|720|||
|**Horsepower Ratings (UL Recognized)**|||**DC Rating—NEMA P300**|||||
||**AC Volts**|||**Maximum Current**|||**Max. Make**|
|**Phase**|**115**|**230**|**Volts**|**Cont.**|**Make**|**Break**|**or Break (VA)**|
|1|1/6|1/2|125|5.0|1.1|1.1|138|
|3|—|1|250|5.0|0.55|0.55|138|
|**Resistive Rating**||||||||
|125 Vdc|3A|||||||
|250 Vdc|1.5A|||||||
|**Coil Power Requirements**||||||||
|AC|72 VA open, 22 VA closed|||||||
|DC|12 watts (nominal), 250V max.|||||||
**3**
## **Permanent Magnet Latch Specifications**
|**Item**|**Specification**|
|---|---|
|Unlatching power requirements|Open gap: 24 VA AC|
||Closed gap: 7 VA|
||Burden: 4 watts (AC)|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-149**
Control Relays and Timers
3.7
Machine Tool Relays
## **Contact Arrangements—BF and BFD Relays**
**==> picture [432 x 247] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 Poles 3 Poles 4 Poles<br>3<br>3<br>3 6 Poles 8 Poles<br>3<br>Rear Rear<br>3<br>3 Front Front<br>3 10 Poles 12 Poles<br>3<br>Rear Rear<br>3<br>3 Center Center<br>3 Front Front<br>**----- End of picture text -----**<br>
**Note:** NO = Normally Open NC = Normally Closed
## **Dimensions**
Approximate Dimensions in Inches (mm)
**BF Relay with Permanent BFD Relay with Solid-State Magnet Latch and SolidTimer State Timer**
**==> picture [243 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
C E<br>B<br>D<br>A<br>3.13 1.97 3.13 1.69<br>(79.5) (50) (79.5) (42.9)<br>**----- End of picture text -----**<br>
## **Enclosures—NEMA 1 for BF, BFD, AR and ARD**
**==> picture [227 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.83<br>(71.9) 5.66<br>(143.8)<br>1.05 1.72 1.72 0.19 (4.8)<br>(26.7) (43.7) (43.7)<br>KO KO KO<br>KO<br>0.25 (6.4) Dia.<br>6.59 Mtg. Holes (3)<br>(167.4) 4.5<br>(114.3)<br>0.63<br>(16)<br>KO<br>KO KO KO<br>1.69 (42.9) 0.38 x 0.5<br>(9.7 x 12.7) A<br>3.38 (85.9) Conduit<br>(2 Top, 2 Bottom)<br>**----- End of picture text -----**<br>
## **BF and BFD Relay Dimensions**
|**Number**|**A**|**B**|**C**|**D**|**E**|
|---|---|---|---|---|---|
|**of Poles**|**BF Only**|**BF w/Latch**|**BF w/Timer**|**BFD Only**|**BFD w/Timer**|
|4|3.22 (81.8)|6.22 (158.0)|5.88 (149.4)|4.03 (102.4)|7.06 (179.3)|
|8<br>12|4.19 (106.4)<br>4.81 (122.2)|7.19 (182.6)<br>7.81 (198.4)|6.88 (174.8)<br>7.50 (190.5)|4.97 (126.2)<br>5.63 (143.0)|8.00 (203.2)<br>8.66 (220.0)|
## **NEMA 1 for BF, BFD, AR and ARD Dimensions**
||**Catalog**|**A**|
|---|---|---|
|**Poles**|**Number**|**NEMA 1**|
|**Relays without Attachments**|||
|All<br>4 – 8|**BF, AR, ARD**<br>**BFD**|5.34 (135.6)<br>5.34 (135.6)|
|10, 12|**BFD**|7.97 (202.4)|
|**Relays with Attachments**|||
|All|**BF, AR, ARD**|7.97 (202.4)|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-150**
Control Relays and Timers
3.7
Machine Tool Relays
## **AR/ARD Series—Convertible Contact Industrial Control**
## **Contents**
**==> picture [244 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Page|
|D15 Series—Freedom 600V Multipole. . . . . . . . . .|V7-T3-140|
|BF/BFD Series—Fixed Contact Industrial|
|Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-145|
|AR/ARD Series—Convertible Contact|
|Industrial Control|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-152|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-153|
|Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-153|
|Technical Data and Specifications . . . . . . . . . .|V7-T3-154|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-155|
|D26 Series—Type M, 600 Vac Multipole|
|with Convertible Contacts . . . . . . . . . . . . . . . . . .|V7-T3-156|
|D26 Series—Type M, DC Multipole|
|with Convertible Contacts . . . . . . . . . . . . . . . . . .|V7-T3-161|
**----- End of picture text -----**<br>
**3**
## **AR/ARD Series—Convertible Contact Industrial Control**
## **Product Description**
The AR/ARD relays are electromechanical convertible contact relays. AR relays are AC devices and the ARD is for DC applications.
## **Application Description**
Type AR and ARD relays are designed for use on machine tools, process lines, conveyors and similar automatic and semiautomatic equipment.
## **Features and Benefits**
## _**Permanent Magnet Latch**_
By energizing the relay coil, the latch attachment “sets” (when the base relay’s armature/crossbar assembly has closed) holding the relay ON, even after the relay coil has been de-energized. The clearing coil on the latch is energized to release the armature/crossbar assembly.
- Field mountable to fourand six-pole
- Latch plunger is adjustable
- Latch coil continuously rated
- Unlatching power requirements
- Open gap: 24 VA
- Closed gap: 7 VA
- Burden: 4 watts AC, 6 watts DC
## _**Surge Suppressor**_
- Mounts in contact cavity of AR relays
- Limits high transient voltages resulting from deenergizing relay coil or other electromechanical devices
- Protects sensitive instruments and solid-state devices
- 120 Vac maximum, not used on Vdc
- For noise suppression, see Catalog Number SS-56 starter mounted surge suppressor.
## **Operation**
AR relays are available in either four- or six-pole configurations. AR relays are easily converted to eight- or 10-poles simply by adding a four-pole deck. In addition, mechanical latch attachments are available with four- and six-pole relays.
Contacts are convertible from NO to NC, to provide any combination desired up to a maximum of 10. For the ARD, the number of poles cannot exceed **four** NC in any pole configuration. Wide spacing of contacts simplifies installation, contact testing and maintenance. Contacts are electrically and mechanically isolated from each other. Overlap contacts are also available in one or two sets. These contacts should be mounted in the center pole positions. AC and DC contact cartridges should not be used in the same relay.
## **Standards and Certifications**
- UL File No. E19223
- CSA File No. LR39402-6, LR54517 and LR54520
## _**Reference Information**_
- ART, ARTD: IL 14510, IL 14485
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-151**
3.7
## Control Relays and Timers
## Machine Tool Relays
## **Product Selection**
## _**When Ordering, Specify**_
- Catalog number of basic relay with 120/60, 110/50 AC coil from AR/ARD Relays table.
**3**
- If a coil voltage other than listed is required, select the suffix code from the Coil Voltage table below and substitute it for the last letter in the catalog number. Example: AR64 **V** for a 110/60 AC coil.
## **AR/ARD Relays**
## **AR/ARD Relays**
||**Contact**|||**AR 600 Vac Relays**<br>**120/60, 110/50 AC Coil**|**ARD 600 Vdc Relays**<br>**120 DC Coil**|
|---|---|---|---|---|---|
|**Number**|||**Blank**|**Catalog**|**Catalog**|
|**of Poles**<br>4<br>6|**NO**<br>0<br>2<br>4<br>0|**NC**<br>0<br>0<br>0<br>0|**Cavities**<br>4<br>2<br>0<br>6|**Number**<br>**AR4A**<br>**AR420A**<br>**AR440A**<br>**AR6A**|**Number**<br>**ARD4S**<br>**ARD420S**<br>**ARD440S**<br>**ARD6S**|
||4|0|2|**AR640A**|**—**|
||6|0|0|**AR660A**|**ARD660S**|
|81|6|0|2|**AR860A**|**ARD860S**2|
||8|0|0|**AR880A**|**ARD880S**|
|101|10|0|0|**AR10100A**|**ARD10100S**|
## **Coil Voltage**
|**AR Coils**|||**ARD Coils**||
|---|---|---|---|---|
|**Volts AC**|**Hz**|**Suffix Code**|**Volts DC**|**Suffix Code**|
|12|60|**F**|12|**D**|
|24|60|**I**|24|**L**|
|48|60|**G**|48|**M**|
|110|60|**V**|95|**B**|
|110/120|50/60|**A**|120|**S**|
|208|60|**B**|130|**U**|
|220/240<br>277|50/60<br>60|**W**<br>**C**|240|**T**|
|380/440|50/60|**H**|||
|440/480|50/60|**X**|||
|550|60|**D**|||
|550/600|50/60|**E**|||
## **Contact Cartridges—600V**
|**Contact Cartridges—600V**|||
|---|---|---|
||**Standard Contact**|**Overlap Contact**|
|**Terminal**|**Cartridge**<br>**Catalog**|**Cartridge**<br>**Catalog**|
|**Type**<br>**AC Cartridges**|**Number**3|**Number**4|
|With clamp terminals|**ARC**|**AROC**|
|With screw terminals|**ARCR**|**AROCR**|
|**DC Cartridges**|||
|With clamp terminals|**ARDC**|**ARDOC**|
|With screw terminals|**ARDCR**|**ARDOCR**|
## _**Notes**_
- 1 Will not accept top-mounted latch or timers.
- 2 Contact Customer Support Center for availability.
- 3 Standard cartridges are sold in cartons of four cartridges. Catalog number is for single cartridge.
- 4 Overlap contact cartridges are sold in sets of two cartridges. Catalog number is for sets of two.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-152**
Control Relays and Timers
3.7
Machine Tool Relays
**==> picture [243 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
ARML Permanent Permanent Magnet Latch<br>Magnet Latch for Operating Catalog<br>AR/ARD Relays Volts Coil Hz Number<br>= i ee!<br>For AC Control Circuits<br>24 60 ARMLI<br>a<br>48 60 ARMLG<br>120 60/50 ARMLA<br>240 60/50 ARMLW<br>For DC Control Circuits<br>24 — ARMLL<br>48 — ARMLM<br>120 — ARMLS<br>240 — ARMLT<br>**----- End of picture text -----**<br>
**3**
## **Accessories**
## _**Four-Pole Top Deck Adder**_
- Increases contact capacity from four/six-poles to eight/10-poles
- Mounts on top of basic relay using three screws
- Will not interfere with wiring, testing or convertible cartridges
- Screw terminals for ring connectors available; to order, add Suffix **R** to catalog number listed below
|**Four-Pole Top**|**Four-Pole Top Deck Adder**|**Four-Pole Top Deck Adder**||
|---|---|---|---|
|**Deck Adder**|**No. of**<br>**Poles**<br>**Contacts**<br>**NO**<br>**NC**|**Blank**<br>**Cavities**|**Catalog**<br>**Number**|
||**With 600 Vac Cartridges**|||
||4<br>2<br>0<br>4<br>0|2<br>0|**ARA20**<br>**ARA40**|
||**With 600 Vdc Cartridges**|||
||4<br>2<br>0|2|**ARDA20**|
||4<br>0|0|**ARDA40**|
**==> picture [204 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
ARSS Surge Surge Suppressor<br>Suppressor for<br>AR Relays Catalog<br>Number<br>Surge Suppressor ARSS<br>**----- End of picture text -----**<br>
## **Options**
## **Convertible Contacts**
|**Convertible Contacts**|||
|---|---|---|
||**Code**|**Catalog**|
|**Description**|**Letter**|**Number**|
|AR and ARD relays listed are supplied with NO contacts that|1|**—**|
|are easily converted to NC. If both NO and NC poles are<br>required, order by catalog number. Example: four-pole relay|||
|with 1NO and 3NC contacts, order AR4**13**A.|||
## **Overlapping Contacts**
|**Overlapping Contacts**|||
|---|---|---|
||**Code**|**Catalog**|
|**Description**|**Letter**|**Number**|
|NO contact closes before corresponding NC contact opens —|**S**or|**—**|
|supplied as NO/NC sets of two cartridges. Insert letter**S**after<br>relay type designation in listed catalog number. Example:|**S2**1||
|AR402A**S**. Specify the number of sets required:**S**for one set|||
|and**S2**for two sets.|||
## **Screw Terminals**
|**Screw Terminals**|||
|---|---|---|
||**Code**|**Catalog**|
|**Description**<br>For ring-type connectors, add suffix**R**to the catalog number.|**Letter**<br>**R**|**Number**<br>**—**|
|Example: AR420A**R**.|||
## _**Note**_
> 1 Consult Customer Support Center for availability.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-153**
Control Relays and Timers
3.7
## Machine Tool Relays
## **Technical Data and Specifications**
## **General**
## **Contact Ratings—600 Vac Cartridge NEMA A600**
**3**
|**Volts**|**Maximum Current**<br>**Cont.**|**Make**|**Break**|**Maximum VA**<br>**Make**|**Break**|
|---|---|---|---|---|---|
|120|10|60|6|7200|720|
|240|10|30|3|7200|720|
|480|10|15|1.5|7200|720|
|600|10|12|1.2|7200|720|
|**DC Cartridges—NEMA P600**|**DC Cartridges—NEMA P600**|||
|---|---|---|---|
||**Maximum Current**||**Maximum VA**|
|||**Make or**|**Make or**|
|**Volts**|**Continuous**|**Break**|**Break**|
|125|5|1.10|138|
|250|5|0.55|138|
|600|5|0.20|138|
|**Resistive Rating**||||
|125 Vdc|3A|||
|250 Vdc|1.5A|||
|**Coil Power Requirements**||||
|AC|96 VA open, 14 VA closed|||
|DC|14 watts open, 250V|max.||
|**Voltage**||**AR Relays**|**ARD Relays**|
|Pickup voltage (max.)||85%|65%|
|Dropout voltage (min.)<br>Voltage (max.)||60%<br>110%|15%<br>110%|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-154**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.7
Machine Tool Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Four- and Six-Pole with Four-Pole Adder, Solid-State Timer and Mechanical Latch**
**==> picture [374 x 201] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.44 (87.4) 4.09 (103.9)<br>2.75 (69.9) Latch 2.88 (73.2) 2.88 (73.2)<br>S.S. Timer<br>Adder Deck<br>Base Relay<br>D<br>C<br>B<br>A<br>3.13 2.05<br>(79.5) 1.44 (36.6) (52.1)<br>C L of Mounting Slots C L of Mounting Slots C L of Mounting Slots<br>(2) for 0.164 Screws (2) for 0.164 Screws (2) for 0.164 Screws<br>End View, 4- and 6-Pole Side View, 4-Pole Side View, 6-Pole<br>**----- End of picture text -----**<br>
**3**
**Four- and Six-Pole with Four-Pole Adder, Solid-State Timer and Mechanical Latch**
|**Relay**|||||
|---|---|---|---|---|
|**Catalog**|**A**|**B**|**C**|**D**|
|**Number**|**Four-, Six-Pole Relays**|**Relay Adder**|**Relay with Timer**|**Relay with Latch**|
|**AR**|3.56 (90.4)|4.94 (125.5)|6.00 (152.4)|6.39 (162.3)|
|**ARD**|4.63 (117.6)|6.00 (152.4)|7.06 (179.3)|7.45 (189.2)|
## **Enclosures—NEMA 1 for BF, BFD, AR and ARD**
**==> picture [227 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.83<br>(71.9) 5.66<br>(143.8)<br>1.05 1.72 1.72 0.19 (4.8)<br>(26.7) (43.7) (43.7)<br>KO KO KO<br>KO<br>0.25 (6.4) Dia.<br>6.59 Mtg. Holes (3)<br>(167.4) 4.5<br>(114.3)<br>0.63<br>(16)<br>KO<br>KO KO KO<br>1.69 (42.9) 0.38 x 0.5<br>(9.7 x 12.7) A<br>3.38 (85.9) Conduit<br>(2 Top, 2 Bottom)<br>**----- End of picture text -----**<br>
## **Enclosures—NEMA 1 for BF, BFD, AR and ARD**
||**Catalog**|**Dimension A**|
|---|---|---|
|**Poles**|**Number**|**NEMA 1**|
|**Relays without Attachments**|||
|All|**BF, AR, ARD**|5.34 (135.6)|
|4–8|**BFD**|5.34 (135.6)|
|10, 12|**BFD**|7.97 (202.4)|
|**Relays with Attachments**|||
|All|**BF, AR, ARD**|7.97 (202.4)|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-155**
Control Relays and Timers
3.7
Machine Tool Relays
**3**
**D26 Series—Type M, 600 Vac Multipole with Convertible Contacts**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D15 Series—Freedom 600V Multipole. . . . . . . . . .|**V7-T3-140**|
|BF/BFD Series—Fixed Contact Industrial||
|Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-145**|
|AR/ARD Series—Convertible Contact||
|Industrial Control . . . . . . . . . . . . . . . . . . . . . . . . .<br>D26 Series—Type M, 600 Vac Multipole<br>with Convertible Contacts<br>Product Selection . . . . . . . . . . . . . . . . . . . . . . .<br>Technical Data and Specifications . . . . . . . . . .|**V7-T3-151**<br>**V7-T3-157**<br>**V7-T3-159**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-160**|
|D26 Series—Type M, DC Multipole||
|with Convertible Contacts . . . . . . . . . . . . . . . . .|**V7-T3-161**|
## **D26 Series—Type M, 600 Vac Multipole with Convertible Contacts**
## **Product Description**
Relays can be ordered as complete devices in any pole combination up to a maximum of 12NO or 8NC and 4NO poles, or can be assembled from components shown on **Page V7-T3-158** .
Relay base assembly ( **D26MB** ) will accept from 1 to 4 rear poles ( **D26MPR** , **D26MPS** and/or **D26MPL** ).
## **Features**
Contact poles D26MPR and D26MPF in 2- through 8-pole relays are convertible NO to NC or vice versa. Simply reverse the terminal screws and rotate the unit pole 180° (in either direction).
## **Options**
Adding a front deck, the total number of poles can be increased to 8, all convertible NO to NC.
Adding a **D26MF** , 4-pole fixed NO attachment, builds a 12pole relay with 8 convertible poles and 4 fixed NO poles.
Relays with mechanical latch are available in any convertible pole combination up to eight poles maximum.
## **Standards and Certifications**
- UL listed—Class No. NKCR2, File E1230(N)
- CSA certified—File LR353
**Normally Closed Contact**
**Normally Open Contact**
To obtain overlapping contacts, use **D26MPS** (NO early closing) and **D26MPL** (NC late opening) rear poles, in related circuits.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-156**
Control Relays and Timers
3.7
Machine Tool Relays
## **Product Selection**
## _**Complete AC Relays**_
When Ordering, Specify
- Catalog number and magnet coil suffix letter.
- Example: For a 4-pole relay having 4NO contacts, order Catalog Number **D26MR40** , with a 120V, 60 Hz coil, order **D26MR40A** .
**3**
- For fast delivery and minimum inventory, it is recommended that component parts or complete relays with NO poles be ordered.
## **4-Pole**
## **Complete AC Relays—Open Type**
|**4-Pole**|**Complete AC Relays—Open Type**|**Complete AC Relays—Open Type**|**Complete AC Relays—Open Type**|||
|---|---|---|---|---|---|
||||||**Relay with**|
|||**Type of Contact**||**Relay Only**|**Mechanical Latch**|
||**Number**|||**Catalog**|**Catalog**|
||**of Contacts**|**NO (Form A)**|**NC (Form B)**|**Number**|**Number**|
||2|2<br>0<br>**D26MR20**<br>**D26MR202**<br>~~a~~||||
|||1|1|**D26MR11**|**D26MR112**|
|||0|2|**D26MR02**|**D26MR022**|
|**4-Pole with Latch**|3|3|0|**D26MR30**|**D26MR302**|
|||2|1|**D26MR21**|**D26MR212**|
|||1|2|**D26MR12**|**D26MR122**|
|||0|3|**D26MR03**|**D26MR032**|
||4|4|0|**D26MR40**|**D26MR402**|
|Pe)||3<br>1<br>**D26MR31**<br>**D26MR312**<br>2<br>2<br>**D26MR22**<br>**D26MR222**<br>~~oo~~||||
|||1|3|**D26MR13**|**D26MR132**|
|**4-Pole with Pneumatic**<br>**Timer Attachment**|**4-Pole with Pneumatic**|0|4|**D26MR04**|**D26MR042**|
||61|6|0|**D26MR60**|**D26MR602**|
|||5|1|**D26MR51**|**D26MR512**|
|||4|2|**D26MR42**|**D26MR422**|
|||3|3|**D26MR33**|**D26MR332**|
|||2|4|**D26MR24**|**D26MR242**|
|||1|5|**D26MR15**|**D26MR152**|
|||0|6|**D26MR06**|**D26MR062**|
||81|8|0|**D26MR80**|**D26MR802**|
|||7|1|**D26MR71**|**D26MR712**|
|||6|2|**D26MR62**|**D26MR622**|
|||5|3|**D26MR53**|**D26MR532**|
|||4|4|**D26MR44**|**D26MR442**|
|||3|5|**D26MR35**|**D26MR352**|
|||2|6|**D26MR26**|**D26MR262**|
|||1|7|**D26MR17**|**D26MR172**|
|||0|8|**D26MR08**|**D26MR082**|
## **Magnet Coil Selection**
|**Volts/Hertz**|**Suffix Code**|**Volts/Hertz**|**Suffix Code**|
|---|---|---|---|
|120/60–110/50|**A**|32/602|**V**|
|240/60–220/50|**B**|12/602|**R**|
|208/602|**E**|6/60|**P**|
|24/60|**T**|380/502|**L**|
|277/60|**H**|480/60 or 440/50|**C**|
|||600/60 or 550/502|**D**|
## _**Notes**_
- 1 **10- and 12-Poles** : The 6 and 8 contact relays (without mechanical latch only) listed above can be provided with four additional NO non-convertible contacts. Add suffix number **4** to above listed catalog number plus magnet coil suffix. Example: For a 12 contact relay, order D26MR80 **4A** .
- 2 Consult Customer Support Center for availability.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-157**
Control Relays and Timers
3.7
Machine Tool Relays
## **Relay Component Parts Location**
**==> picture [215 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 fa D26MFFront AttachmentTimer Attachments or<br>Mechanical Latch<br>3<br>D26MD10<br>3 Front Deck<br>D26MF<br>D26MB<br>Front Attachment<br>3 Relay BaseAssembly Pneumatic Timer or<br>Mechanical Latch<br>**----- End of picture text -----**<br>
## **Relay with Pneumatic Timer Attachment Factory Installed (without Relay Contacts)**
|**Contact**||**Timer**|**Catalog**|
|---|---|---|---|
|**Positions**<br>4|**Positions**1|**Operation**<br>ON delay|**Number**2<br>**D26MR005**|
|4||OFF delay|**D26MR006**|
For additional information on timer attachment, see **Page V7-T3-159** .
The relays listed above will For additional information accept up to four catalog on timer attachment, see number D26MPR contacts **Page V7-T3-159** . (convertible—NO or NC) for For assembly of relays from instantaneous operation. component parts and relay Order contacts separately. accessories, see components tables below.
## **Separate Contacts**
## **Rear Pole**
||**Separate Contacts**||
|---|---|---|
||**Description**<br>**Convertible Contacts**|**Catalog**<br>**Number**|
|Rear pole—NO<br>**D26MPR**<br>Rear pole—NC<br>**D26MPR02**<br>Front pole—NO<br>**D26MPF**<br>Front pole—NC<br>**D26MPF02**<br>Gold plated<br>(for low power circuits)<br>~~CC~~|||
||Rear pole—NO|**D26MPR03**|
||Front pole—NO|**D26MPF03**|
||**Non-Convertible Contacts**||
||Rear pole NO early closing3<br>Rear pole NC late opening3|**D26MPS**<br>**D26MPL**|
## **Front Pole**
|**Relay Base**<br>**Assembly**|**Relay Base Assembly (without Poles)**<br>**Description**<br>Relay base assembly|**Relay Base Assembly (without Poles)**<br>**Catalog**<br>**Number**<br>**D26MB**4|
|---|---|---|
Basic four-pole D26 relay as needed, **D26MPR,** without contacts. Provision **D26MPL** and/or **D26MPS** for adding one to four poles rear pole type.
## **Front Deck (Convertible Contact Poles)**
## **Rear Pole**
||**Catalog**|
|---|---|
|**Description**|**Number**|
|**Front Deck with …**||
|1NO contact pole<br>2NO contact poles|**D26MD10**<br>**D26MD20**|
|4NO contact poles|**D26MD40**|
Provides up to four additional front pole type D26MPF contacts. Convertible, NO to NC.
|**Four-Pole Front**<br>**Attachment**<br>‘|**Four-Pole Front Attachment**<br>**(4NO Fixed Circuit)**<br>**Description**<br>Front attachment|**Four-Pole Front Attachment**<br>**Catalog**<br>**Number**<br>**D26MF**|
|---|---|---|
Can be added to any two- to eight-pole Type M, D26 relay to provide up to a 12-pole
relay. Four NO, nonconvertible contacts are included in this assembly.
## _**Notes**_
- 1 Number of available instantaneous contact positions (order contacts separately—Catalog Number D26MPR).
- 2 Consult Customer Support Center for availability.
- 3 To obtain overlapping contacts, these two special poles must be used in related circuits.
- 4 Add magnet coil suffix letter, see **Page V7-T3-157** . Example: D26MB **A** .
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-158**
Control Relays and Timers
3.7
Machine Tool Relays
**Relay State Relay State Indicating Light Indicating Light Catalog Description Number** 120 Vac, 50/60 Hz **D26MAP120** 240 Vac, 50/60 Hz **D26MAP240** Light provided with leads and ~— used to monitor state bracket for mounting on twoof magnet coil or relay to 12-pole relays. May be contact operation.
## **Manual Test Accessory**
## **Manual Test Accessory**
||**Catalog**|
|---|---|
|**Description**<br>Manual test accessory|**Number**<br>**D26MTA**|
Tool to manually hold relays in the energized position for circuitry testing on completed
panel. (10 per box, order in multiples of 10.)
## **Transient Suppressor**
**Transient Suppressor**
**Pneumatic Timer Pneumatic Timer Attachment Attachment Catalog Description Number** es ON delay ~~CD~~ **D26MTE** - OFF delay **D26MTD**
|**Transient Suppressor**||
|---|---|
|**Description**<br>Magnet coil transient suppressor|**Catalog**<br>**Number**<br>**D26MAS1**|
|Latch coil transient suppressor|**D26MAS2**|
May be mounted on any 120 Vac relay magnet coil or latch coil or 120 Vdc latch coil—connects directly across coil terminals. All DC magnet coils have a built-in varistor for transient suppression.
Limits high voltage transients produced in the circuit when power is removed from the coil.
Attachment mounts on any 0- to four-pole D26 relay without latch. Timer unit has DPDT timed contacts (circuits in each pole must be the same polarity). Adjustable timing
range—0.1 to 180 seconds, repeat accuracy ±10%. Units are convertible from OFF delay to ON delay or vice versa.
**3**
**Mounting Channel Mounting Channel**
|**Mounting Channel**||
|---|---|
|**Description**<br>10 in length for 4 relays<br>20 in length for 8 relays<br>30 in length for 12 relays|**Catalog**<br>**Number**<br>**D26MC4**<br>**D26MC8**<br>**D26MC12**|
|40 in length for 16 relays|**D26MC16**|
Pre-spaced mounting for length. Captive mounting adjacent relay installation. screws provided in channel Indexed for cutting to desired for easier installation.
## **Technical Data and Specifications**
## **General**
|**General**||||||
|---|---|---|---|---|---|
|**Contact Ratings (Amperes) A600**|**Contact Ratings (Amperes) A600**<br>**Make and**|||||
||**Emergency**|||||
|**AC Volts**1|**Interrupting**<br>**Capacity**|**Break**|**Continuous**<br>**Thermal Rating**|||
|120|60|6|10|||
|240|30|3|10|||
|480|15|1.5|10|||
|600|12|1.2|10|||
|**Coil Power**|||||**Operating Time**|
||**Watts**||**VA**||**Range in**|
|**Relay**|**Inrush**|**Sealed**|**Inrush**|**Sealed**|**Milliseconds**|
|Two- to 12-pole|95.0|9|155|22|Pickup: 6–13|
|Latch coil|18.5|11|41|17|Dropout: 8–26|
_**Note**_
> 1 For DC contact ratings, see **Page V7-T3-163** .
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-159**
Control Relays and Timers
3.7
Machine Tool Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **AC and DC D26 Relays**
**3**
|**AC Relay**<br>**D26**<br>3.50<br>(88.9)|||||D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|
|---|---|---|---|---|---|---|---|---|---|---|---|
||||||238 (605)<br>D26MAS2<br>0.75<br>(19.1)<br><br>2 Holes<br>#10 Screw|||||||
|||||||||||||
||50<br>8.9)||||||||||3.<br>(79|
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||238 (605)<br>0.75<br>(19.1)|||||0.<br>(11|
|||||||||||||
|1–4 poles|||||1–3 poles<br>4.00 (101.6)<br>2.5 (1.1)|||||||
|1–4 poles with timer D26 or D87<br>1–3 poles with timer D26 or D87<br>6.00 (152.4)<br>3.3 (1.5)||||||||||||
|1–4 poles with latch<br>1–2 poles with latch<br>6.13 (155.7)<br>3.5 (1.6)||||||||||||
|1–4 poles with d26mf<br>1–3 poles with D26MF<br>5.81 (147.6)<br>2.8 (1.3)||||||||||||
|5–8 poles<br>4–7 poles<br>5.25 (133.4)<br>2.8 (1.3)||||||||||||
|5–8 poles with timer D87<br>4–7 poles with timer D87<br>7.25 (184.2)<br>3.5 (1.6)||||||||||||
|5–8 poles with latch<br>3–6 poles with latch<br>7.31 (185.7)<br>3.8 (1.7)||||||||||||
|9–12 poles<br>8–11 poles<br>7.00 (177.8)<br>3.0 (1.4)||||||||||||
## **Mounting Channel**
**==> picture [301 x 193] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>0.69 B 1.06<br>(17.5) 2.50 2.38 (26.9) 0.38<br>(63.5) (60.5) (9.7)<br>Type<br>M<br>3.63 Relay<br>(92.2) D26<br>1.25 2.50 1.38<br>(31.8) (63.5) (35.1)<br>Catalog<br>Number Dimension A Dimension B<br>D26MC16 40 (1016) 37.5 (952.5)<br>D26MC12 30 (762) 27.5 (698.5)<br>D26MC8 20 (508) 17.5 (444.5)<br>D26MC4 10 (254) 7.5 (190.5)<br>**----- End of picture text -----**<br>
**Note:** Channel mounts through keyholes with #10 screws (two each end and one every fourth relay). Relays mount with screws captive in channel. All screws must be tightened firmly.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-160**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.7
Machine Tool Relays
**==> picture [173 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
D26 Series—Type M, DC Multipole with Convertible Contacts<br>**----- End of picture text -----**<br>
## **Contents**
**==> picture [244 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Page|
|D15 Series—Freedom 600V Multipole. . . . . . . . . .|V7-T3-140|
|BF/BFD Series—Fixed Contact Industrial|
|Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-145|
|AR/ARD Series—Convertible Contact|
|Industrial Control . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-151|
|D26 Series—Type M, 600 Vac Multipole|
|with Convertible Contacts . . . . . . . . . . . . . . . . . .|V7-T3-156|
|D26 Series—Type M, DC Multipole|
|with Convertible Contacts|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-162|
|Technical Data and Specifications . . . . . . . . . .|V7-T3-163|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-164|
**----- End of picture text -----**<br>
**3**
## **D26 Series—Type M, DC Multipole with Convertible Contacts**
## **Product Description**
Type M, DC multipole relays are physically and mechanically similar to the (D26) Type M AC relays described on **Page V7-T3-157** . They differ only in the electrical ratings and available pole combinations due to the use of a normally closed late opening, coil clearing contact, factory wired to the pickup winding of the magnet coil. (Contact is shown as L in figure to the right.) Magnet coil has built-in varistor for transient suppression.
The mechanically latched relay has one extra contact, normally open early closing, factory wired in series with the winding of the intermittent rated latch coil. (Contact is shown as S in figure to the right.)
## **Component parts for**
**these relays** are the same as those listed for the (D26) Type M AC relays on **Page V7-T3-157** , except for the Indicating Light, which is not applicable to a DC relay.
Contact poles D26MPR and D26MPF in 2- to 7-pole relays are convertible NO to NC or vice versa. Simply reverse the terminal screws and rotate the unit pole 180° (in either direction).
## **Latch Operation**
**DC Type M Relay**
With the latch coil deenergized, energizing the relay coil will pick up the relay DC Input and mechanically latch it in LS1 the pickup position. With the L ~~o~~ Pick-Up relay coil de-energized, energizing the latch coil will L = NC Late Opening allow the relay to drop out.
**Convertible Contacts DC Type M Relay with Latch** DC Input Relay Coil LS1 LPick-Up **Normally Closed Contact** Hold (Not Used) L = NC Late Opening Latch **Normally OpenContact** LS1 S Coil fete ~~Le~~ Release S = NO Early Closing
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-161**
Control Relays and Timers
3.7
Machine Tool Relays
## **Product Selection**
## _**Complete DC Relays**_
When Ordering, Specify
**3** ~~I~~
- Catalog number and magnet coil suffix letter.
- Example: For a 4-pole relay having 4NO contacts, order Catalog Number **D26MRD40** , with a 120 Vdc coil, order **D26MRD40A1** .
## **Complete DC Relays—Open Type**
## **3-Pole**
|**3-Pole**|**3-Pole**||**Complete DC Relays—Open Type**|**Complete DC Relays—Open Type**|**Complete DC Relays—Open Type**|||
|---|---|---|---|---|---|---|---|
|||||**Type of Contact**1||**Relay Only**|**Relay with**<br>**Mechanical Latch**|
||||**Number**<br>**of Contacts**|**NO (Form A)**|**NC (Form B)**|**Catalog**<br>**Number**|**Catalog**<br>**Number**|
||||2|2<br>1<br>~~a~~|0<br>1<br>~~a~~|**D26MRD20**<br>**D26MRD11**<br>~~a~~|**D26MRD202**<br>**D26MRD112**<br>~~a~~|
||||3|0<br>3|2<br>0|**D26MRD02**<br>**D26MRD30**|**D26MRD022**<br>**D26MRD302**|
|**3-Pole with Latch**|**3-Pole with Latch**|**3-Pole with Latch**||||||
|||||2|1|**D26MRD21**|**D26MRD212**|
|||||1|2|**D26MRD12**|**D26MRD122**|
|||||0|3|**D26MRD03**|**D26MRD032**|
||||4|4|0|**D26MRD40**|**D26MRD402**|
|||||3|1|**D26MRD31**|**D26MRD312**|
|||||2|2|**D26MRD22**|**D26MRD222**|
|||||1|3|**D26MRD13**|**D26MRD132**|
|||||0|4|**D26MRD04**|**D26MRD042**|
||||62|6|0|**D26MRD60**|**D26MRD602**|
|||||5|1|**D26MRD51**|**D26MRD512**|
|||||4|2|**D26MRD42**|**D26MRD422**|
|||||3<br>2|3<br>4|**D26MRD33**<br>**D26MRD24**|**D26MRD332**<br>**D26MRD242**|
|||||1<br>0|5<br>6|**D26MRD15**<br>**D26MRD06**|**D26MRD152**<br>**D26MRD062**|
||||72|7|0|**D26MRD70**|**—**|
|||||6|1|**D26MRD61**|**—**|
|||||5|2|**D26MRD52**|**—**|
|||||4|3|**D26MRD43**|**—**|
|||||3|4|**D26MRD34**|**—**|
|||||2|5|**D26MRD25**|**—**|
|||||1|6|**D26MRD16**|**—**|
|||||0|7|**D26MRD07**|**—**|
||||**Magnet Coil Selection**<br>**Volts/Hertz**|**Magnet Coil Selection**<br>**Suffix Code**|**Volts/Hertz**|**Suffix Code**||
||||12<br>24|**R1**<br>**T1**|120<br>240|**A1**<br>**B1**||
||||48|**W1**||||
## _**Notes**_
- 1 Relay has additional factory wired normally closed coil clearing contact (see diagram).
- 2 **10- and 11-Poles** : The 6 and 7 contact relays (without mechanical latch only) listed above can be provided with four additional NO non-convertible contacts. Add suffix number **4** to above listed catalog number plus magnet coil suffix. Example: For an 11 contact relay, order D26MRD70 **4A1** .
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-162**
Control Relays and Timers
3.7
Machine Tool Relays
|**3-Pole with Timer**<br>**Attachment**|**Relay with Pneumatic Timer Attachment**<br>**(without Relay Contacts)**|**Relay with Pneumatic Timer Attachment**|
|---|---|---|
||**Contact**<br>**Timer**|**Catalog**|
||**Positions**1<br>**Operation**|**Number**|
||3<br>ON delay|**D26MRD005**|
||3<br>OFF delay|**D26MRD006**|
Order contacts separately. For additional information on timer attachment, see **Page V7-T3-159** .
The relays listed above will accept up to three catalog number D26MPR contacts (convertible—NO or NC) for instantaneous operation.
**3**
## **Technical Data and Specifications**
## **General**
|**General**||||
|---|---|---|---|
|**Contact Ratings (Amperes)**|**Contact Ratings (Amperes)**2|||
||**Inductive**|**Resistive**||
|**DC Volts**|**Make/Break**|**Make/Break**||
|28|7.0|10.0||
|48|2.5|10.0||
|120|1.1|2.0||
|240|0.2|0.4||
|**Coil Power**|||**Operating Time**|
||**Watts**||**Average**|
|**Relay**|**Inrush**|**Sealed**|**Milliseconds**|
|Two- to 11-pole|168|13.2|Pickup: 10|
|Latch coil|21.6 intermittent|21.6 intermittent|Dropout: 16|
## _**Notes**_
- 1 Number of available instantaneous contact positions (order contacts separately—Catalog Number D26MPR).
- 2 Contact ratings do not apply to contacts D26MPL and D26MPS. For AC contact ratings, see **Page V7-T3-159** .
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-163**
Control Relays and Timers
3.7
Machine Tool Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **AC and DC D26 Relays**
**3**
|**AC Relay**<br>**D26**<br>3.50<br>(88.9)|||||D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|D26MAS1<br><br>1 Slot<br>#10 Screw|
|---|---|---|---|---|---|---|---|---|---|---|---|
||||||238 (605)<br>D26MAS2<br>0.75<br>(19.1)<br><br>2 Holes<br>#10 Screw|||||||
|||||||||||||
||50<br>8.9)||||||||||3.<br>(79|
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||238 (605)<br>0.75<br>(19.1)|||||0.<br>(11|
|||||||||||||
|1–4 poles|||||1–3 poles<br>4.00 (101.6)<br>2.5 (1.1)|||||||
|1–4 poles with timer D26 or D87<br>1–3 poles with timer D26 or D87<br>6.00 (152.4)<br>3.3 (1.5)||||||||||||
|1–4 poles with latch<br>1–2 poles with latch<br>6.13 (155.7)<br>3.5 (1.6)||||||||||||
|1–4 poles with D26MF<br>1–3 poles with D26MF<br>5.81 (147.6)<br>2.8 (1.3)||||||||||||
|5–8 poles<br>4–7 poles<br>5.25 (133.4)<br>2.8 (1.3)||||||||||||
|5–8 poles with timer D87<br>4–7 poles with timer D87<br>7.25 (184.2)<br>3.5 (1.6)||||||||||||
|5–8 poles with latch<br>3–6 poles with latch<br>7.31 (185.7)<br>3.8 (1.7)||||||||||||
|9–12 poles<br>8–11 poles<br>7.00 (177.8)<br>3.0 (1.4)||||||||||||
## **Mounting Channel**
**==> picture [301 x 193] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>0.69 B 1.06<br>(17.5) 2.50 2.38 (26.9) 0.38<br>(63.5) (60.5) (9.7)<br>Type<br>M<br>3.63 Relay<br>(92.2) D26<br>1.25 2.50 1.38<br>(31.8) (63.5) (35.1)<br>Catalog<br>Number Dimension A Dimension B<br>D26MC16 40 (1016) 37.5 (952.5)<br>D26MC12 30 (762) 27.5 (698.5)<br>D26MC8 20 (508) 17.5 (444.5)<br>D26MC4 10 (254) 7.5 (190.5)<br>**----- End of picture text -----**<br>
**Note:** Channel mounts through keyholes with #10 screws (two each end and one every fourth relay). Relays mount with screws captive in channel. All screws must be tightened firmly.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-164**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.8
Timing Relays
**==> picture [42 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Timing Relays<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||**3**|
|---|---|---|
|**_Description_**|**_Page_**||
|Timing Relays||**3**|
|Universal TR Series . . . . . . . . . . . . . . . . . . . . .<br>TR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>TMR5 Series . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>TMR6 Series . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>TMRP Series . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-170**<br>**V7-T3-174**<br>**V7-T3-177**<br>**V7-T3-181**<br>**V7-T3-183**|**3**<br>**3**<br>**3**|
## **Product Selection Guide**
## **Function Code Cross-Reference Guide**
|||**Timer Series**||||||
|---|---|---|---|---|---|---|---|
|**Function**|**Description**|**Universal TR**|**TR**|**TMR5**|**TMR6**|**TMRP**|**E5-248**3|
|1<br>2|Asymmetrical flasher, pause first<br>Asymmetrical flasher, pulse first|lp<br>li|—<br>—|R/P<br>Y|—<br>—|—<br>—|RC DLY<br>RC|
|3<br>4|ON delay and OFF delay with control contact<br>ON delay and single shot leading edge voltage controlled|ER<br>EWu|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|
|5|ON delay and single shot leading edge control contact|EWs|—|—|—|—|—|
|6|Single shot leading and single shot trailing edge with control contact|WsWa|—|—|—|—|—|
|7|Pulse sequence monitoring|Wt|—|—|—|—|—|
|8<br>9|ON delay, power triggered<br>Single shot leading edge voltage controlled|E<br>Wu|A1<br>B1|N<br>T|—<br>—|A<br>C|—<br>—|
|10|OFF delay/signal OFF delay|R|E2|F|—|D|OFF DLY|
|11|Single shot leading edge with control input|Ws|F2|C/G|—|H|SS|
|12|Single shot trailing edge with control input|Wa|—|—|—|—|—|
|13|ON delay control signal start, trailing edge OFF|Es|—|—|—|—|—|
|14|Flasher, pause first|Bp|C1|L|—|B|—|
|15<br>16|Retriggerable single shot<br>Flasher, ON first|—<br>—|—<br>D1|W/D<br>—|—<br>—|E<br>F|SS<br>—|
|17|ON delay control signal start, leading edge OFF|—|A2|—|—|—|ON DLY|
|18|Flasher—control signal start, pause first|—|B2|—|—|—|RC DLY|
|19|Flasher—control signal start, ON first|—|C2|—|—|—|RC|
|20<br>21|Signal ON/OFF delay<br>ON/OFF delay|—<br>—|D2<br>—|—<br>—|—<br>—|—<br>I|—<br>—|
|22<br>23|Single pulse generator<br>Memory latch|—<br>—|—<br>—|—<br>—|—<br>—|G<br>J|OS<br>—|
|24|True OFF delay|—|—|—|X|—|—|
## _**Notes**_
- 1 Applies to TRN model only.
- 2 Applies to TRF model only.
- 3 The E5-248 is battery powered and has three programmable trigger functions. This product may perform somewhat differently from the standard timing relays. Refer to the operator instructions for details.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-165**
3.8
## Control Relays and Timers
Timing Relays
## **Product Overview**
## **Timer Function Descriptions**
## **Function #1—Universal TR, TMR5, E5-248 Asymmetrical Flasher, Pause First 3 Repeat Cycle, OFF/ON Delay**
After the interval t2 has expired, the output relay switches into OFF position. The output relay is triggered at the ratio of t1:t2 until the supply voltage is interrupted.
When the supply voltage U is applied, the set interval t1 begins. After the interval t1 has expired, the output relay R switches into ON position and the set interval t2 begins.
**==> picture [239 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Output LED**<br>Output Relay (R) t1 t2 t1 t2 t1<br>**----- End of picture text -----**<br>
## **Function #2—Universal TR, TMR5, E5-248 Asymmetrical Flasher, Pulse First Repeat Cycle, ON/OFF Delay**
When the supply voltage U is applied, the output relay R switches into the ON position and the set interval t1 begins. After the interval t1 has expired, the output relay R switches into OFF position
and the set interval t2 begins. After the interval t2 has expired, the output relay switches into ON position. The output relay is triggered at the ratio of t1:t2 until the supply voltage is interrupted.
**==> picture [239 x 47] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Output LED**<br>Output Relay (R) t1 t2 t1 t2 t1<br>**----- End of picture text -----**<br>
## **Function #3—Universal TR ON Delay and OFF Delay with Control Contact**
interval t2 begins. After the interval t2 has expired, the output relay R switches into OFF position. If the control contact is opened before the interval t1 has expired, the interval already expired is erased and is restarted with the next cycle.
The supply voltage U must be constantly applied to the device. When the control contact S is closed, the set interval t1 begins. After the interval t1 has expired, the output relay R switches into ON position. If the control contact is opened, the set
**==> picture [242 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Trigger Signal (S)<br>Output LED**<br>Output Relay (R) t1 t2 <t1<br>**----- End of picture text -----**<br>
## **Function #4—Universal TR ON Delay and Single Shot Leading Edge Voltage Controlled**
switches into OFF position. If the supply voltage is interrupted before the interval t1 + t2 has expired, the interval already expired is erased and is restarted when the supply voltage is next applied.
When the supply voltage U is applied, the set interval t1 begins. After the interval t1 has expired, the output relay R switches into ON position and the set interval t2 begins. After the interval t2 has expired, the output relay
**==> picture [239 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Output LED**<br>Output Relay (R) t1 t2<br>**----- End of picture text -----**<br>
## **Function #5—Universal TR ON Delay and Single Shot Leading Edge Control Contact**
interval t2 begins. After the interval t2 has expired, the output relay R switches into OFF position. During the interval, the control contact is ignored. A new cycle can only be initiated when the cycle has been completed.
The supply voltage U must be constantly applied to the device. When the control contact S is closed, the set interval t1 begins. After the interval t1 has expired, the output relay R switches into ON position and the set
**==> picture [242 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Trigger Signal (S)<br>Output LED**<br>Output Relay (R) t1 t2<br>**----- End of picture text -----**<br>
## **Function #6—Universal TR Single Shot Leading and Single Shot Trailing Edge with Control Contact Asymmetrical Signal ON/OFF Delay**
The supply voltage U must be constantly applied to the device. When the control contact S is closed, the output relay R switches to the ON position and the set interval t1 begins. After the interval t1 has expired, the output relay R switches into OFF position. If the control contact S is opened, the
output relay again switches to the ON position and the set interval t2 begins. After the interval t2 has expired, the output relay R switches into OFF position. During the interval, the control contact is ignored. During the interval, the control contact can be operated any number of times.
**==> picture [242 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Trigger Signal (S)<br>Output LED**<br>Output Relay (R) t1 t2 t1 t2<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-166**
Control Relays and Timers
3.8
Timing Relays
## **Function #7—Universal TR Pulse Sequence Monitoring**
When the supply voltage U interval t2, the relay will is applied, the set interval t1 remain in the ON position. begins and the output relay If the control switch is not R switches to the ON closed and opened within position. After the interval the interval t2, the relay t1 has expired, the interval will change to the OFF t2 begins. As long as the position until supply control switch S is closed voltage U is interrupted and opened within the and reapplied.
**==> picture [242 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Trigger Signal (S)<br>Output LED**<br>Output Relay (R) t1 <t2 <t2 <t2 t2<br>**----- End of picture text -----**<br>
## **Function #8—Universal TR, TRN, TMR5, TMRP ON Delay, Power Triggered Delay ON Make**
R switches to the ON position. The relay will remain in that position until supply voltage U is interrupted.
When the supply voltage U is applied, the set interval t begins. After the interval t has expired, the output relay
**==> picture [238 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Output LED**<br>Output Relay (R) t <t<br>**----- End of picture text -----**<br>
## **Function #9—Universal TR, TRN, TMR5, TMRP Single Shot Leading Edge Voltage Controlled Interval ON/Interval (Power Start)**
When the supply voltage U The relay will remain in that is applied, the output relay R position until supply voltage U switches to the ON position is interrupted. If the supply and set interval t begins. voltage is interrupted prior to After the interval t has interval t timing out, the relay expired, the output relay R will immediately switch to the switches to the OFF position. OFF position.
|Input Power (U)<br>LED U/t*<br>Output LED**<br>Output Relay (R)||||||
|---|---|---|---|---|---|
|||||||
|||||||
||t|||<t||
## **Function #10—Universal TR, TRF, TMR5, TMRP, E5-248 OFF Delay/Signal OFF Delay Delay ON Release**
The supply voltage U must be constantly applied to the device. When the control contact S is closed, the output relay R switches to the ON position. When the control contact is opened, interval t begins. After the interval t has expired, the
output relay R switches to the OFF position. If the control contact S is closed before interval t expires, the output relay will remain in the ON position until the control switch opens, at which time the interval t will begin again.
**==> picture [242 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Trigger Signal (S)<br>Output LED**<br>Output Relay (R) t <t<br>**----- End of picture text -----**<br>
**Function #11—Universal TR, TRF, TMR5, TMRP, E5-248 Single Shot Leading Edge with Control Input Single Shot/One Shot (Signal Start)/Momentary Interval**
The supply voltage U must be constantly applied to the device. When the control contact S is closed, the output relay R switches to the ON position and the set interval t begins. After the
interval t has expired, the output relay R switches to the OFF position. The control contact is ignored during the interval t, and a new cycle cannot be started until the set interval t has timed out.
**==> picture [242 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Trigger Signal (S)<br>Output LED**<br>Output Relay (R) t t<br>**----- End of picture text -----**<br>
**Function #12—Universal TR Single Shot Trailing Edge with Control Input**
The supply voltage U must be constantly applied to the device. When the control contact S is closed and reopened, the output relay R switches to the ON position and the set interval t begins. After the interval t
has expired, the output relay R switches to the OFF position. The control contact is ignored during the interval t, and a new cycle must be started after the set interval t has timed out.
**==> picture [243 x 61] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Trigger Signal (S)<br>Output LED**<br>Output Relay (R) t t<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-167**
Control Relays and Timers
3.8
## Timing Relays
## **Function #13—Universal TR ON Delay Control Signal Start, Trailing Edge OFF**
The supply voltage U must **3** be constantly applied to the device. When the control switch S is applied, the set **3** interval t begins. After the interval t has expired, the **3** output relay R switches to the ON position. The relay
will remain in that position until the control switch opens. If the control switch is opened prior to interval t timing out, the relay will remain in the OFF position and any elapsed time will be erased.
**==> picture [243 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Trigger Signal (S)<br>Output LED**<br>Output Relay (R) t <t<br>**----- End of picture text -----**<br>
## **Function #14—Universal TR, TRN, TMR5, TMRP Flasher, Pause First Cycle 1 (Power Start, OFF First)**
When the supply voltage U has expired, the relay will is applied, the set interval t switch to the OFF position begins. After the interval t for the set interval t. This has expired, the output relay cycle will repeat at a 1:1 R switches to the ON ratio until supply voltage U position and set interval t will is interrupted. begin again. After interval t
**==> picture [239 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>LED U/t*<br>Output LED**<br>Output Relay (R) t t t t t <t<br>**----- End of picture text -----**<br>
## **Function #15—TMR5, TMRP, E5-248 Watchdog Retriggerable Single Shot**
switches to the OFF position. Closing the control switch during interval t will reset the time. Continuous cycling of the trigger signal at a rate faster than the preset time will cause the relay to remain in the ON position.
The supply voltage U must be constantly applied to the device. When the control switch S is applied, the relay switches to the ON position and the set interval t begins. After the interval t has expired, the output relay R
**==> picture [243 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>Trigger Signal (S)<br>Output Relay (R) t <t <t t<br>**----- End of picture text -----**<br>
## **Function #16—TRN, TMRP Flasher, ON First Cycle 3 (Power Start, ON First)**
When the supply voltage U After interval t has expired, is applied, the relay switches the relay will again switch to to the ON position and set the ON position for the set interval t begins. After the interval t. This cycle will interval t has expired, the repeat at a 1:1 ratio until output relay R switches to supply voltage U is the OFF position and set interrupted. interval t will begin again.
**==> picture [239 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>Output LED**<br>Output Relay (R) t t t t t t <t<br>**----- End of picture text -----**<br>
## **Function #17—TRF, E5-248 ON Delay Control Signal Start, Leading Edge OFF**
The supply voltage U must be constantly applied to the device. When the control switch S is applied, the set interval t begins. After the interval t has expired, the output relay R switches to the ON position. The relay will remain in that position
until the control switch has opened and closed. If the control switch is opened and closed prior to interval t timing out, the relay will remain in the OFF position and any elapsed time will be erased.
**==> picture [239 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>Trigger Signal<br>Output LED**<br>Output Relay (R) t t<br>**----- End of picture text -----**<br>
## **Function #18—TRF, E5-248 Flasher—Control Signal Start, Pause First**
After interval t has expired, the relay will switch to the OFF position for the set interval t. This cycle will repeat at a 1:1 ratio until supply voltage U is interrupted. The control switch is ignored during the cycle.
The supply voltage U must be constantly applied to the device. When the control switch S is closed, the set interval t begins. After the interval t has expired, the output relay R switches to the ON position and set interval t will begin again.
**==> picture [239 x 47] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>Trigger Signal<br>Output LED**<br>Output Relay (R) t t t t <t<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-168**
Control Relays and Timers
3.8
Timing Relays
## **Function #19—TRF, E5-248 Flasher—Control Signal Start, ON First**
The supply voltage U must again. After interval t has be constantly applied to the expired, the relay will again device. When the control switch to the ON position switch S is closed, the relay for the set interval t. This switches to the ON position cycle will repeat at a 1:1 and set interval t begins. ratio until supply voltage U After the interval t has is interrupted. The control expired, the output relay R switch is ignored during switches to the OFF position the cycle. and set interval t will begin
**==> picture [239 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>Trigger Signal<br>Output LED**<br>Output Relay (R) t t t t <t<br>**----- End of picture text -----**<br>
## **Function #20—TRF Signal ON/OFF Delay**
The supply voltage U must position. When the control be constantly applied to the switch is opened, the relay device. When the control will switch to the ON position switch S is closed, the relay again and the interval t will switches to the ON position begin. If the control switch is and set interval t begins. closed and opened within the After the interval t has interval t, the relay will remain expired with the control in the ON position until switch still closed, the output interval t has timed out after relay R switches to the OFF the control switch is opened.
**==> picture [239 x 47] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>Trigger Signal<br>Output LED**<br>Output Relay (R) t t <t t<br>**----- End of picture text -----**<br>
## **Function #21—TMRP ON/OFF Delay Make/Break with Control Switch Trigger**
The supply voltage U must be constantly applied to the device. When the control switch S is closed, the set interval t begins. After the interval t has expired, the output relay R switches to the ON position. When the
control switch is opened, interval t will begin again. After interval t has timed out, the relay will switch to the OFF position. If supply voltage U is removed at any time, the relay will return to the OFF position.
**==> picture [238 x 47] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>Trigger Signal<br>Output LED**<br>Output Relay (R) t t t<br>**----- End of picture text -----**<br>
## **Function #22—TMRP, E5-248 Single Pulse Generator, Voltage Controlled**
When the supply voltage U 0.5 seconds before returning is applied, the set interval t to the OFF position. Supply begins. After the interval t voltage U must be removed has expired, the relay will and reapplied to repeat the switch to the ON position for pulse.
**==> picture [240 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>Output LED**<br>Output Relay (R) t t<br>**----- End of picture text -----**<br>
## **Function #23—N/A Memory Latch Control Switch Make**
The supply voltage U must with every closure of the be constantly applied to the control switch S (leading device. Output changes state edge).
**==> picture [240 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>Trigger Signal<br>Output LED**<br>Output Relay (R)<br>**----- End of picture text -----**<br>
## **Function #24—TMR6 True OFF Delay**
When the supply voltage U is applied, the relay switches to the ON position. When supply power is removed, set time interval t begins. After
interval t has expired, the relay switches to the OFF position and will remain there until supply power U is applied again.
**==> picture [239 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Power (U)<br>Output Relay (R) t<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-169**
Control Relays and Timers
3.8
Timing Relays
**3**
## **Universal TR Series**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Universal TR Series||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-171**|
|Technical Data and Specifications . . . . . . . . . .|**V7-T3-171**|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-172**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-173**|
|TR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-174**|
|TMR5 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-177**|
|TMR6 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-181**|
|TMRP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-183**|
## **Universal TR Series**
## **Product Description**
Eaton’s Universal TR Series timers are our most flexible and cost-effective timing relays available. Products are available with up to seven user-selectable functions and seven user-selectable time ranges. Each unit is DIN rail mountable with a direct connection, eliminating the need for additional sockets. The Universal TR Series timers are available in SPDT and DPDT contact configurations, and have a compact IEC-style footprint and a universal input voltage range for AC and DC applications.
## **Application Description**
A timing relay is a simple form of time-based control, allowing the user to open or close the contacts based on a specified timing function. The Universal TR Series timers are equipped with a set of selector switches, which can easily be set to a specific function and time, thereby reducing the number of product variations required. The universal input voltage (either 12–240 Vac/Vdc or 24–240 Vac/Vdc, depending on the model) further reduces the number of product variations.
The Universal TR Series timers are ideal for highvariability operations, such as systems integrators, distributors, and small equipment manufacturers. The compact design saves panel space, and the low cost and high flexibility of the units reduce inventory requirements.
## **Features**
- Multiple user-selectable timing functions and timing ranges in a single unit reduce product variations and stock keeping units (SKUs)
- Universal input voltages from 12 or 24 to 240 Vac or Vdc eliminate the need to order and stock separate coil voltages
- Compact, DIN rail mountable case reduces panel size
- Advanced LED indication makes troubleshooting easy
- Staggered terminal locations allow access to lower-level terminals after wiring
- SPDT or DPDT contacts with 8A ratings
## **Standards and Certifications**
- cULus listed
- CE marked
- RoHS compliant
- IEC/EN 61812
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-170**
Control Relays and Timers
3.8
Timing Relays
## **Product Selection**
## **Universal TR Timing Relays**
|||**Universal TR Timing Relays**|**Universal TR Timing Relays**||
|---|---|---|---|---|
|**Single-Pole Model**||**Universal TR Timing Relays**|**Universal TR Timing Relays**|**Catalog**|
|aa<br>ee|||**Supply Voltage**<br>**4-Function**<br>24–240 Vac/Vdc<br>**7-Function**<br> ~~$$~~|**Description**<br>Compact DIN rail mount, SPDT|**Number**<br>**TRL04**|
|||24–240 Vac/Vdc|Compact DIN rail mount, SPDT|**TRL07**|
|||12–240 Vac/Vdc|Compact DIN rail mount, DPDT<br>Asymmetrical pulse generator, DPDT|**TRL27**<br>**TRW27**|
**3**
## **Technical Data and Specifications**
## **Universal TR Timing Relays**
|**Description**|**TRL04**|**TRL07**|**TRL27**|**TRW27**|
|---|---|---|---|---|
|Functions1|E, R, Wu, Bp|E, R, Wu, Bp, Ws, Wa, Es|E, R, Wu, Bp, Ws, Wa, Es|Ii, Ip, ER, Ewu, Ews, WsWa, Wt|
|Time range<br>**Input**|0.05 sec to 100 hours|0.05 sec to 100 hours|0.05 sec to 100 hours|0.05 sec to 100 hours|
|Supply voltage|24–240 Vac/Vdc|24–240 Vac/Vdc|12–240 Vac/Vdc|12–240 Vac/Vdc|
|Rated supply frequency|+10% /–15%|+10% /–15%|±10%|±10%|
|Rated consumption|4 VA (1.5W)|4 VA (1.5W)|6 VA (2W)|6 VA (2W)|
|Duty cycle<br>Reset time|100%<br>100 ms|100%<br>100 ms|100%<br>100 ms|100%<br>100 ms|
|Residual ripple for DC<br>dropout voltage|10%<br>>30% of rated supply voltage|10%<br>>30% of rated supply voltage|10%<br>>30% of rated supply voltage|10%<br>>30% of rated supply voltage|
|Overvoltage category|III (in accordance with IEC 60664-1)|III (in accordance with IEC 60664-1)|III (in accordance with IEC 60664-1)|III (in accordance with IEC 60664-1)|
|Rated surge voltage|4 kV|4 kV|4 kV|4 kV|
|**Output**|||||
|Contact configuration<br>Rated voltage|SPDT (one changeover contact)<br>250 Vac|SPDT (one changeover contact)<br>250 Vac|DPDT (two changeover contacts)<br>250 Vac|DPDT (two changeover contacts)<br>250 Vac|
|Switching capacity|2000 VA (8A/250V)|2000 VA (8A/250V)|2000 VA (8A/250V)|2000 VA (8A/250V)|
|Fusing|8A fast acting|8A fast acting|8A fast acting|8A fast acting|
|Mechanical life|20 x 10^6 operations|20 x 10^6 operations|20 x 10^6 operations|20 x 10^6 operations|
|Electrical life|2 x 10^5 operations at 1000 VA load,|2 x 10^5 operations at 1000 VA load,|2 x 10^5 operations at 1000 VA load,|2 x 10^5 operations at 1000 VA load,|
||resistive|resistive|resistive|resistive|
|Switching frequency|Max. 6/min. at 1000 VA resistive load|Max. 6/min. at 1000 VA resistive load|Max. 6/min. at 1000 VA resistive load|Max. 6/min. at 1000 VA resistive load|
||(in accordance with IEC 60947-5-1)|(in accordance with IEC 60947-5-1)|(in accordance with IEC 60947-5-1)|(in accordance with IEC 60947-5-1)|
|Overvoltage category|III (in accordance with IEC 60664-1)|III (in accordance with IEC 60664-1)|III (in accordance with IEC 60664-1)|III (in accordance with IEC 60664-1)|
|Rated surge voltage|4 kV|4 kV|4 kV|4 kV|
|**Control Signal**<br>Loadable|Yes|Yes|Yes|Yes|
|Maximum cable length<br>Trigger level (sensitivity)|10m<br>Automatic adaption to|10m<br>Automatic adaption to|10m<br>Automatic adaption to|10m<br>Automatic adaption to|
|Minimum control pulse length|supply voltage<br> DC 50 ms/AC 100 ms|supply voltage<br>DC 50 ms/AC 100 ms|supply voltage<br>DC 50 ms/AC 100 ms|supply voltage<br>DC 50 ms/AC 100 ms|
## _**Note**_
> 1 Refer to Function Code Cross-Reference Guide on **Page V7-T3-165** for function details.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-171**
Control Relays and Timers
3.8
Timing Relays
## **Universal TR Timing Relays, continued**
**3**
|**Description**|**TRL04**|**TRL07**|**TRL27**|**TRW27**|
|---|---|---|---|---|
|**Accuracy**|||||
|Base accuracy|±1% of maximum scale value|±1% of maximum scale value|±1% of maximum scale value|±1% of maximum scale value|
|Adjustment accuracy|<5% of maximum scale value|<5% of maximum scale value|<5% of maximum scale value|<5% of maximum scale value|
|Repetition accuracy<br>Temperature influence|<0.5% or ±5 ms<br><<br>~~0~~.01% /°C|<0.5% or ±5 ms<br><<br>0.01% /°C|<0.5% or ±5 ms<br><<br>~~0~~.01% /°C|<0.5% or ±5 ms<br><<br>0.01% /°C|
|**Physical**|||||
|Ambient temperature|–25 to 55°C|–25 to 55°C|–25 to 55°C|–25 to 55°C|
|Storage temperature|–25 to 70°C|–25 to 70°C|–25 to 70°C|–25 to 70°C|
|Relative humidity|15% to 85% (in accordance|15% to 85% (in accordance|15% to 85% (in accordance|15% to 85% (in accordance|
||with IEC 60721-3-3 Class 3K3)|with IEC 60721-3-3 Class 3K3)|with IEC 60721-3-3 Class 3K3)|with IEC 60721-3-3 Class 3K3)|
|Pollution degree|2, if built in 3 (in accordance|2, if built in 3 (in accordance|2, if built in 3 (in accordance|2, if built in 3 (in accordance|
||with IEC 60664-1)|with IEC 60664-1)|with IEC 60664-1)|with IEC 60664-1)|
|Housing material|Self-extinguishing plastic housing,|Self-extinguishing plastic housing,|Self-extinguishing plastic housing,|Self-extinguishing plastic housing,|
||IP40 rating|IP40 rating|IP40 rating|IP40 rating|
|Mounting|Mounted on DIN rail TS 35 according|Mounted on DIN rail TS 35 according|Mounted on DIN rail TS 35 according|Mounted on DIN rail TS 35 according|
||to EN 60715, any position|to EN 60715, any position|to EN 60715, any position|to EN 60715, any position|
|Terminal rating|Shockproof terminal connection|Shockproof terminal connection|Shockproof terminal connection|Shockproof terminal connection|
||according to VBG 4 (PZ1 required),<br>IP20 rating|according to VBG 4 (PZ1 required),<br>IP20 rating|according to VBG 4 (PZ1 required),<br>IP20 rating|according to VBG 4 (PZ1 required),<br>IP20 rating|
|Tightening torque|Max. 1 Nm|Max. 1 Nm|Max. 1 Nm|Max. 1 Nm|
## **Terminal Capacity**
## **Description**
1 x 0.5 to 2.5 mm[2] with/without multicore cable end
1 x 4 mm[2] without multicore cable end
2 x 0.5 to 1.5 mm[2] with/without multicore cable end
2 x 2.5 mm[2] flexible without multicore cable end
## **Wiring Diagrams**
**Single-Pole, Double-Throw Units (SPDT)— TRL04 and TRL07**
**==> picture [201 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
(+)<br>U =<br>(–)<br>S (Used only for<br>control switch<br>triggered functions)<br>15<br>A1 B1<br>A1 15<br>R<br>A2 16 18<br>A2<br>16 18<br>**----- End of picture text -----**<br>
**Double-Pole, Double-Throw Units (DPDT)— TRL27 and TRW27**
**==> picture [238 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
(+)<br>U =<br>(–)<br>S (Used only for<br>control switch<br>triggered functions)<br>15 25<br>A1 B1<br>A1 15 25<br>R R<br>A2 16 18 26 28<br>A2<br>16 18 26 28<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-172**
Control Relays and Timers
3.8
Timing Relays
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **17.5 mm (TRL04 and TRL07)**
**==> picture [233 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.77 3.43<br>(45.0) (87.0)<br>0.20 1.73<br>(5.0) (44.0) 0.69<br>2.36 (17.5)<br>(60.0)<br>**----- End of picture text -----**<br>
## **35 mm (TRL27 and TRW27)**
**==> picture [239 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.77 3.43<br>(45.0) (87.0)<br>0.20 1.73<br>(5.0) (44.0) 1.38<br>2.36 (35.0)<br>(60.0)<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-173**
Control Relays and Timers
3.8
Timing Relays
**3**
**==> picture [29 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
TR Series<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Universal TR Series . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-170**|
|TR Series||
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V7-T3-175**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-175**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-175**|
|Technical Data and Specifications . . . . . . . . . .|**V7-T3-176**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-176**|
|TMR5 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-177**|
|TMR6 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-181**|
|TMRP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-183**|
## **TR Series**
## **Product Description**
The upgraded TR Series Timing Relays are designed to meet most timing requirements by offering more flexibility in range of input voltage, timing range and functionality. Use a rotary switch to choose from 20 selectable time ranges from 0.1 second to 600 hours. We offer both a power triggered and signal triggered model—each with expanded operation modes. There is a green LED to indicate when power is ON and an orange LED when output is ON.
## **Features**
- 20 time ranges and 10 timing functions
- Time delays from 0.1 sec to 600 hrs
- Space-saving, compact package
- High repeat accuracy of ± 0.2%
- LED indication
- Standard 8- or 11-pin and 11-blade termination
- 2 Form C DPDT delayed output contacts
- 10A contact rating
## **Operation**
## **TRNP and TRNB**
**==> picture [166 x 216] intentionally omitted <==**
**----- Start of picture text -----**<br>
Internal Connections<br>1 2 3<br>4 5 4 5 6<br>3 6<br>7 8 9<br>2 7<br>1 8 A B<br>(–/+) (–/–)<br>(–/+) (–/–)<br>TRNP TRNB<br>TRFP and TRFB<br>Internal Connections<br>External External<br>Control Start Control Start<br>Signal Signal<br>1 2 3<br>6 7<br>4 [5] 8 4 5 6<br>3 9<br>7 8 9<br>2 10<br>1 11 A B<br>ian<br>(–/+) (–/–) (–/+) (–/–)<br>TRFP TRFB<br>**----- End of picture text -----**<br>
## **TRFP and TRFB**
## **Standards and Certifications**
- cULus listed
- CSA
- CE marked
- TUV TUV
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-174**
Control Relays and Timers
3.8
Timing Relays
## **Catalog Number Selection**
**==> picture [95 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
TR N P 240 AC<br>**----- End of picture text -----**<br>
**==> picture [343 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
Family Type Input Voltage<br>TR 24AD = 24 Vac<br>(50/60 Hz)/24 Vdc<br>Operational Mode 240AC = 100–240 Vac<br>(50/60 Hz)<br>N = Power Triggered F = Signal Triggered<br>A = ON delay A = ON delay, control signal start<br>B = Interval (leading edge OFF) Model Type<br>C = Flasher (pause first) B = Flasher, control signal start P = Pin/octal<br>D = Flasher (ON first) (pause first) B = Blade style<br>C = Flasher, control signal Start<br>(ON first)<br>D = Signal ON/OFF delay<br>E = OFF delay<br>F = Single shot leading edge with<br>control input<br>**----- End of picture text -----**<br>
## **Product Selection**
## **Accessories**
**Sockets for Use with TR Timers—Standard Pack of 10**
## **TR Plug-In Timing Relays—Power Triggered**
||**Octal**<br>**Catalog**|**Blade**<br>**Catalog**|
|---|---|---|
|**Coil Voltage**|**Number**|**Number**|
|24 Vac/Vdc|**TRNP24AD**|**TRNB24AD**|
|100–240 Vac|**TRNP240AC**|**TRNB240AC**|
|**Timing Relay**|**Terminal Style**|**Catalog**<br>**Number**|
|---|---|---|
|TRNP|8-pin octal|**D3PA2**|
|TRFP|11-pin octal|**D3PA3**|
|TRNB, TRFB|0.187 in solder/QC terminals|**D5PA2**|
||(blade style)||
**3**
## **TR Plug-In Timing Relays—Signal Triggered**
||**Octal**|**Blade**|
|---|---|---|
||**Catalog**|**Catalog**|
|**Coil Voltage**|**Number**|**Number**|
|24 Vac/Vdc|**TRFP24AD**|**TRFB24AD**|
|100–240 Vac|**TRFP240AC**|**TRFB240AC**|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-175**
Control Relays and Timers
3.8
**3**
## Timing Relays
## **Technical Data and Specifications**
## **General**
|**General**||
|---|---|
|**Description**|**Specification**|
|Operation system|Solid-state CMOS circuit|
|Time range|0.1 sec to 600 hours|
|Pollution degree|2 (IE60664-1)|
|Overvoltage category|III (IE60664-1)|
|Rated operational voltage||
|240 AC|100–240 Vac (50/60 Hz)|
|24 AC|24 Vac (50/60 Hz)/24 Vdc|
|12 DC<br>Voltage tolerance|12 Vdc|
|240 AC<br>24 AC|85–264 Vac (50/60 Hz)<br>20.4–26.4 Vac (50/60 Hz)/21.6–26.4 Vdc|
|12 DC|10.8–13.2 Vdc|
|Input OFF voltage|Rated voltage x 10% minimum|
|Ambient operating temperature|–4 to 149°F (–20 to 65°C)|
|Reset time|100 ms maximum|
|Repeat error|± 0.2%, ± 20 ms1|
|Voltage error<br>Temperature error|± 0.2%, ± 20 ms1<br>± 0.5%, ± 20 ms1|
|Setting error<br>Insulation resistance|± 10% maximum<br>100M ohm minimum (500 Vdc)|
|Dielectric strength||
|Between power and output terminals|2000 Vac, 1 minute|
|Between contacts of different poles|2000 Vac, 1 minute|
|Between contacts of same pole|1000 Vac, 1 minute|
|Vibration resistance|10–55 Hz amplitude 0.5 mm;|
||2 hrs in each of 3 axes|
|Shock resistance||
|Operating extremes<br>Damage limits —|10G|
|TRNP, TRFP<br>TRNB, TRFB|40G (3x in each of 3 axes)<br>10G (3x in each of 3 axes)|
|Power consumption (approx.)||
|240 AC|6.5 VA TRNP, TRNB/6.6 VA TRFP, TRFB|
|240 Vac/60 Hz|11.6 VA TRNP, TRNB/12.1 VA TRFP, TRFB|
|24 AC (AC/DC)|3.4 VA–1.7W TRNP, TRNB/3.5 VA–1.7W TRFP,|
||TRFB|
|12 DC|1.6W|
## **Dimensions**
Approximate Dimensions in Inches (mm) **TR Series Dimensions and Weights**
|**Description**|**Specification**|
|---|---|
|**Dimensions**||
|TRNP, TRFP|1.58H x 1.42W x 3.07D in. (40H x 36W x 77.9D mm)|
|TRNB, TRFB|1.58H x 1.42W x 2.95D in. (40H x 36W x 74.9D mm)|
|**Weights**||
|TRNP|87g|
|TRFP|89g|
|TRNB, TRFB|85g|
**==> picture [172 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.07 (77.9) 2.95 (74.9)<br>Pin (P) Type Blade (B) Type<br>**----- End of picture text -----**<br>
## _**Note**_
> 1 For the value of the error against a preset time, whichever value is larger should apply.
## **TR Series Contact Ratings**
|**TR Series Contact Ratings**||
|---|---|
|**Description**|**Specification**|
|Contact configuration<br>Allowable voltage/current|2 Form C, DPDT (delayed output)<br>240 Vac, 30 Vdc/10A|
|Max. permissible operating frequency|1800 cycles per hour|
|Rated load||
|Resistive|10A, 240 Vac/30 Vdc|
|Inductive|7A, 240 Vac/30 Vdc|
|Horsepower rating|1/6 hp 120 Vac, 1/3 hp 240 Vac|
|Life<br>Electrical|500,000 operations minimum (resistive)|
|Mechanical|50,000,000 operations minimum|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-176**
Control Relays and Timers
3.8
Timing Relays
## **TMR5 Series**
## **Contents**
## _**Description**_
|**Contents**<br>**_Description_**||
|---|---|
|**_Description_**|**_Page_**|
|Universal TR Series . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-170**|
|TR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-174**|
|TMR5 Series||
|Catalog Number Selection . . . . . . . . . . . . . . . .<br>Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-178**<br>**V7-T3-178**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Technical Data and Specifications . . . . . . . . . .|**V7-T3-178**<br>**V7-T3-179**|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-179**<br>**V7-T3-180**|
|TMR6 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>TMRP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-181**<br>**V7-T3-183**|
**3**
## **TMR5 Series**
## **Product Description**
The TMR5 Series Time Delay Relays are designed for a broad range of OEM applications. The TMR5 Series offers non-programmable plug-in style timers with a variety of functions available. Each unit offers a single function and single input voltage, and operates over a defined time delay range. Units with fixed time delays are also available. Eaton also offers customization capabilities for these timers—remote adjustments, special pin configurations, and more. Contact us to discuss your specific application and design of a custom timer.
## **Features**
- Single timing range for each unit
- Ranges available from 0.02 sec to 24 hours
- Wide variety of functions available
- Plugs into standard 8- or 11-pin socket
- 10A DPDT output contacts
- Can be easily customized to meet your needs
## **Standards and Certifications**
- cRUus
- UL listed (with Eaton socket)
- RoHS compliant
- CE marked
**==> picture [17 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
with<br>Eaton<br>socket<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-177**
Control Relays and Timers
3.8
Timing Relays
## **Catalog Number Selection**
**3**
All configurations from Catalog Number Selection are available.
## **TMR5 N 05 120**
**Input Voltage 120** = 120 Vac/Vdc **24** = 24 Vac/Vdc **12** = 12 Vac/Vdc **240** = 240 Vac/Vdc
- **Family Type**
- **TMR5**
- **Operational Mode**
- **8-Pin Octal Sockets 11-Pin Octal Sockets**
- **N** = ON delay **F** = OFF delay, control switch trigger **T** = Interval ON **C** = Single shot, control switch trigger **L** = Flasher-pause-first **W** = Watchdog, control switch trigger **R** = Repeat cycle[1] (retriggerable single shot) (OFF time first followed by **P** = OFF delay, power trigger ON time and repeating) **G** = Single shot, power trigger
- **Y** = Repeat cycle[1] **D** = Watchdog, power trigger (retriggerable (ON time first followed by single shot) OFF time and repeating)
**Timing Range**[2] **04** = 0.05–5 sec **05** = 0.1–10 sec **08** = 0.6–60 sec **12** = 3–300 sec **15** = 0.3–30 min **16** = 0.6–60 min **22** = 6 sec–10 min
## **Product Selection**
## **Accessories**
## **Accessories for Use with TMR5 Time Delay Relays**
## **TMR5 Time Delay Relays**
|**TMR5 Time Delay Relays**||
|---|---|
|**Input**<br>**Voltage**<br>**Socket**|**Timing**<br>**Range**<br>**Catalog**<br>**Number**|
|**ON Delay**||
|120 Vac/Vdc<br>8-pin<br>24 Vac/Vdc|0.1–10 sec<br>**TMR5N05120**|
||0.6–60 sec<br>**TMR5N08120**|
||0.1–10 sec<br>**TMR5N0524**|
||0.6–60 sec<br>**TMR5N0824**|
|**OFF Delay, Control Switch Trigger**||
|120 Vac/Vdc<br>11-pin<br>24 Vac/Vdc|0.1–10 sec<br>**TMR5F05120**|
||0.6–60 sec<br>**TMR5F08120**|
||0.1–10 sec<br>**TMR5F0524**|
||0.6–60 sec<br>**TMR5F0824**|
|**Interval ON**||
|120 Vac/Vdc<br>8-pin<br>24 Vac/Vdc|0.1–10 sec<br>**TMR5T05120**|
||0.6–60 sec<br>**TMR5T08120**|
||0.1–10 sec<br>**TMR5T0524**|
||0.6–60 sec<br>**TMR5T0824**|
|**Single Shot, Control Switch Trigger**||
|120 Vac/Vdc<br>11-pin<br>24 Vac/Vdc|0.1–10 sec<br>**TMR5C05120**|
||0.6–60 sec<br>**TMR5C08120**|
||0.1–10 sec<br>**TMR5C0524**|
||0.6–60 sec<br>**TMR5C0824**|
|**Repeat Cycle**<br>**(OFF Time First Followed by ON Time and Repeating)**||
|120 Vac/Vdc<br>8-pin<br>24 Vac/Vdc|0.1–10 sec<br>**TMR5R05120**|
||0.6–60 sec<br>**TMR5R08120**|
||0.1–10 sec<br>**TMR5R0524**|
||0.6–60 sec<br>**TMR5R0824**|
|**Repeat Cycle**<br>**(ON Time First Followed by OFF Time and Repeating)**||
|120 Vac/Vdc<br>8-pin<br>24 Vac/Vdc|0.1–10 sec<br>**TMR5Y05120**|
||0.6–60 sec<br>**TMR5Y08120**|
||0.1–10 sec<br>**TMR5Y0524**|
||0.6–60 sec<br>**TMR5Y0824**|
||||**Catalog**|
|---|---|---|---|
||**Description**|**Standard Pack**|**Number**|
||8-pin socket|10|**D3PA2**|
||11-pin socket|10|**D3PA3-A2**|
||Hold-down spring|10|**D65CHDS**|
## _**Notes**_
- 1 Indicates DUAL knob unit. All dual knob units can have independently selectable and adjustable ON and OFF times. If different ON and OFF times are desired, add two codes for time ranges in the part number. The first code listed indicates the first timing range of the unit (OFF time for R, ON time for Y) and the second code indicates the second timing range (ON time for R, OFF Time for Y).
- 2 Fixed time delay settings are available for orders of 50 pieces or more. Contact EatonCare for additional information at 877-ETN-CARE (386-2273).
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-178**
Control Relays and Timers
3.8
Timing Relays
## **Technical Data and Specifications**
## **TMR5 Time Delay Relays**
|**Description**|**Specification**|
|---|---|
|Voltage tolerance||
|AC operation|+10/–15% of nominal at 50/60 Hz|
|DC operation|+10/–15% of nominal|
|Load burden|2 VA|
|Setting accuracy||
|Maximum setting (adjustable)|+5%, –0%|
|Minimum setting (adjustable)|+0%, –50%|
|Fixed time delay||
|< 2 seconds|+1%|
|0.1–2 seconds|±5%|
|Repeat accuracy (constant voltage and temperature)||
|> 2 seconds delay|±0.1%|
|0.1–2 seconds delay|±2%|
|Reset time||
|ON Delay/interval/repeat cycle|0.1 second|
|OFF Delay/single shot/watchdog|0.04 second|
|Startup time (time from when power|is applied until unit is timing)|
|120 and 240V units|0.05 second|
|12, 24 and 48V units|0.08 second|
|Maintain function time (time unit|0.01 second|
|continues to time after power is||
|removed)||
|Temperature||
|12–120V input voltage|–18 to 150°F (–28 to 65°C)|
|240V input voltage|–18 to 122°F (–28 to 50°C)|
|Insulation voltage|2000V|
|Output contacts|DPDT 10A @ 240 Vac/30 Vdc,|
||1/2 hp @ 120/240 Vac (NO contacts)|
||1/3 hp @ 120/240 Vac (NC contacts)|
||B300 and R300; AC-15 and DC-13|
|Life||
|Mechanical|10,000,000 operations|
|Full load|100,000 operations|
## **Wiring Diagrams**
## **Wiring for 8-Pin Units Wiring for 11-Pin Control Switch Trigger Units**
**==> picture [226 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
Control<br>Switch<br>4 5<br>3 6 5 6 7<br>4 8<br>2 7<br>1 8 3 9<br>(DC)+ −(DC) 2 10<br>L1 L2 1 11<br>Input Voltage<br>(DC)+ (DC)−<br>L1 L2<br>Input Voltage<br>**----- End of picture text -----**<br>
## **Wiring for 11-Pin Power Trigger Units**
**==> picture [96 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power<br>+ Trigger * −<br>5 6 7<br>4 8<br>3 9<br>2 10<br>1 11<br>(DC)+ (DC)−<br>L1 L2<br>Input Voltage<br>* Should Be Same Voltage<br>as Input Voltage<br>**----- End of picture text -----**<br>
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-179**
Control Relays and Timers
3.8
Timing Relays
**3**
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **TMR5**
**==> picture [274 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dual Knob<br>Only<br>2.40<br>(61.0)<br>2.90 (73.7)<br>1.70<br>(43.2) 3.50 (88.9)<br>**----- End of picture text -----**<br>
## **D3PA2 Socket**
**==> picture [220 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
6–32 x 0.312 Combination<br>Head Screw and Pressure Clamping Plate<br>(8 places)<br>Two 0.165<br>2.14 (4.2) Dia.<br>(54.3) Slots<br>2.03<br>(51.6)<br>0.82 (20.8)<br>1 .30<br>(33.0) 0.58 (14.7)<br>1.60 0.97<br>(40.6) (24.6)<br>Max. Tolerances: ± 0.010 Max.<br> ± (0.25)<br>Unless Otherwise Shown<br>**----- End of picture text -----**<br>
## **D3PA3 Socket**
**==> picture [200 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
6–32 x 0.312 Combination<br>Head Screw and Pressure Clamp<br>(11 places)<br>Two 0.17<br>(4.3) Dia.<br>2.05 Holes<br>(52.1)<br>Max.<br>2.06 0.15 (3.8)<br>(52.3) 0.13–0.16 0.58 (14.7)<br> (3.2–4.0) 0.77 (19.6)<br>2.33 (59.2) 0.97<br>Max. (24.6)<br>Tolerances: ± 0.010<br> ± (0.25)<br>Unless Otherwise Shown<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-180**
Control Relays and Timers
3.8
Timing Relays
**==> picture [38 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
TMR6 Series<br>**----- End of picture text -----**<br>
## **Contents**
**==> picture [243 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Page|
|Universal TR Series . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-170|
|TR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-174|
|TMR5 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-177|
|TMR6 Series|
|Catalog Number Selection . . . . . . . . . . . . . . . .|V7-T3-182|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-182|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-182|
|Technical Data and Specifications . . . . . . . . . .|V7-T3-182|
|Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-182|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-182|
|TMRP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-183|
**----- End of picture text -----**<br>
**3**
## **TMR6 Series**
## **Product Description**
Most electronic time delay relays with an OFF delay function require input voltage to be applied continuously in order to operate correctly. However, there are many applications where this is not possible—-keeping a relay energized for some amount of time after input voltage has been removed. Eaton’s TMR6 true OFF delay product provides this function even when input voltage is removed. It duplicates the operation of the older OFF delay pneumatic time delay relays.
## **Operation**
## **Features**
- Provides OFF delay function without requiring input voltage during OFF time delay
## _**True OFF Delay**_
Upon application of input **Voltage must be applied for** voltage, the relay is **a minimum of 0.1 second to** energized. When the input **assure proper operation.** voltage is removed, the Any application of the input preset time begins. At the voltage during the preset end of the preset time, the time will keep the relay relay is de-energized. energized and reset the time delay. No external trigger switch is required.
- Duplicates operation of pneumatic OFF delay timers
- Each unit has eight timing ranges built in, covering 0.05 seconds to 30 minutes
## **True OFF Delay**
- Selecting a range is easy using a rotary switch (no math is required or DIP switches to set)
**==> picture [149 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input ON<br>Power<br>(Voltage)<br>OFF<br>ON<br>Output Delay<br>(Load)<br>OFF<br>**----- End of picture text -----**<br>
- Uses industry-standard 8-pin octal socket
- 10A DPDT output contacts
## _**Timing Ranges**_
Select one of the eight timing ranges using the selector knob, and then adjust the time within that range for an accurate delay setting.
## **Standards and Certifications**
- cRUus
## **Timing Ranges**
- UL listed (with Eaton socket)
- RoHS compliant
**==> picture [210 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Dial Setting|Timing Range||RoHS compliant|
|A|0.05–5 sec.|●|CE marked|
|a|
|a|B|0.1–10 sec.|
|C|0.3–30 sec.|
|OO|cehus|with|
|D|0.6–60 sec.|Eaton|
|socket|
|E|1.8–180 sec.|
|F|3–300 sec.|
|G|0.1–10 min.|
|H|0.3–30 min|
**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-181**
Control Relays and Timers
3.8
Timing Relays
**3**
## **Catalog Number Selection**
All configurations from Catalog Number Selection are available.
## **TMR6 X 00 120**
**==> picture [217 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
Family Type Input Voltage<br>TMR6 120 = 120 Vac/Vdc<br>24 = 24 Vac/Vdc<br>Operational Mode 240 = 240 Vac/Vdc<br>X = True OFF delay<br>Timing Range<br>00 = Programmable<br>**----- End of picture text -----**<br>
## **Product Selection**
## **Wiring Diagram**
## **Wiring for 8-Pin Units**
**==> picture [96 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 5<br>3 6<br>2 7<br>1 8<br>(DC)+ −(DC)<br>L1 L2<br>Input Voltage<br>**----- End of picture text -----**<br>
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **TMR6 True OFF Delay Relays**
|**TMR6 True OFF Delay Relays**||
|---|---|
|**Input**<br>**Voltage**<br>**Timing**<br>**Range**|**Catalog**<br>**Number**|
|**True OFF Delay**||
|120 Vac/Vdc<br>0.05 sec–30 min<br>(user selectable, 8 ranges)<br>24 Vac/Vdc<br>240 Vac/Vdc|**TMR6X00120**|
||**TMR6X0024**|
||**TMR6X00240**|
## **Accessories**
## **Accessories for Use with TMR6 Time Delay Relays**
|||**Catalog**|
|---|---|---|
|**Description**<br>8-pin socket|**Standard Pack**<br>10|**Number**<br>**D3PA2**|
|Hold-down spring|10|**D65CHDS**|
## **Technical Data and Specifications**
## **TMR6 Time Delay Relays**
|**Description**<br>Voltage tolerance|**Specification**|
|---|---|
|AC operation<br>DC operation|+10/–15% of nominal at 50/60 Hz<br>+10/–15% of nominal|
|Load burden|2 VA|
|Setting accuracy||
|Maximum setting (adjustable)|+5%, –0%|
|Minimum setting (adjustable)|+0%, –50%|
|Repeat accuracy (constant voltage<br>and temperature)|±0.1% or 50 ms, whichever is greater|
|Temperature<br>Insulation voltage|–18 to 150°F (–28 to 65°C)<br>2,000V|
|Output contacts|DPDT 10A @ 240 Vac/30 Vdc,<br>1/2 hp @ 120/240 Vac (NO contacts)|
||1/3 hp @ 120/240 Vac (NC contacts)|
||B300 and R300; AC-15 and DC-13|
|Life||
|Mechanical|2,000,000 operations|
|Full load|100,000 operations|
## **TMR6**
**==> picture [241 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.40<br>(61.0)<br>2.90 (73.7)<br>1.70<br>(43.2) 3.50 (88.9)<br>**----- End of picture text -----**<br>
## **D3PA2 Socket**
**==> picture [219 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
6–32 x 0.312 Combination<br>Head Screw and Pressure Clamping Plate<br>(8 places)<br>Two 0.165<br>2.14 (4.2) Dia.<br>(54.3) Slots<br>2.03<br>(51.6)<br>0.82 (20.8)<br>1 .30<br>(33.0) 0.58 (14.7)<br>1.60 0.97<br>(40.6) (24.6)<br>Max. Tolerances: ± 0.010 Max.<br> ± (0.25)<br>Unless Otherwise Shown<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-182**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.8
Timing Relays
## **TMRP Series**
## **Contents**
**==> picture [243 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Page|
|Universal TR Series . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-170|
|TR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-174|
|TMR5 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-177|
|TMR6 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-181|
|TMRP Series|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-184|
|Technical Data and Specifications . . . . . . . . . .|V7-T3-184|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-185|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|V7-T3-185|
**----- End of picture text -----**<br>
**3**
## **TMRP Series**
## **Product Description**
Eaton’s TMRP Series timers combine flexibility with ease of use and installation to make the most versatile timer in our offering. The thumbwheel setting design allows for quick selection and review of up to 10 timing functions and seven timing ranges. The TMRP units can be mounted in a 1/16 DIN cutout or on a DIN rail with our D3 series sockets. Input voltage is 12– 240 Vac/Vdc to work with all popular control voltages.
## **Application Description**
A timing relay is a simple form of time-based control, allowing the user to open or close the contacts based on a specified timing function. The TMRP series is equipped with a set of thumb-wheel style selector switches, which can easily be set to a specific function and time, thereby reducing the number of product variations required. The universal input voltage of 12–240 Vac/Vdc further reduces the number of product variations.
The TMRP timers are ideal for high-variability operations, such as systems integrators, distributors, and small equipment manufacturers. The flexible enclosure design allows for back-panel mounting, through-panel mounting, or DIN rail mounting.
## **Features**
- Multiple user-selectable ● Flexible design for backtiming functions and timing panel, through-panel ranges in a single unit (45 mm x 45 mm cutout), reduce product variations or DIN rail mounting and stock keeping units ● SPDT or DPDT contacts (SKUs)
- SPDT or DPDT contacts with 12A ratings
- Universal input voltages ● Plastic dust cover keeps from 12–240 Vac/Vdc out contaminants and eliminate the need to eliminates accidental set order and stock separate point changes coil voltages
- Use with standard Eaton
- ● Timing ranges up to 9990 D3 sockets—see Technical hours Data and Specifications
- Dual LED indication makes troubleshooting easy
## **LED Indicator**
**==> picture [206 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|LED Description|Function|
|Solid green “Input”|Supply voltage present|
|Solid red “Output”|Relay energized|
|Slowly flashing red “Output”|Timing cycle activated, relay not energized|
|Rapidly flashing red “Output”|Timing cycle activated, relay energized|
**----- End of picture text -----**<br>
## **Standards and Certifications**
- UL recognized
- CE marked
- RoHS compliant
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-183**
Control Relays and Timers
3.8
Timing Relays
## **Product Selection**
**3**
|**TMRP5100**|**TMRP Timing Relays**|**TMRP Timing Relays**||
|---|---|---|---|
||||**Catalog**|
||**Supply Voltage**|**Description**|**Number**|
||**10-Function**|||
||12–240 Vac/Vdc|Control switch trigger, DPDT|**TMRP5100**|
|||Control switch trigger, SPDT|**TMRP5101**|
|||Power trigger, DPDT|**TMRP5102**|
## **Technical Data and Specifications**
## **TMRP Timing Relays**
|**TMRP Timing Relays**||||
|---|---|---|---|
|**Description**|**TMRP5100**|**TMRP5101**|**TMRP5102**|
|Functions1|A, B, C, D, E, F, G, H, I, J|A, B, C, D, E, F, G, H, I, J|A, B, C|
|Time range<br>**Input**|0.1 sec to 9,990 hours|0.1 sec to 9,990 hours|0.1 sec to 9,990 hours|
|Supply voltage|12–240 Vac/Vdc|12–240 Vac/Vdc|12–240 Vac/Vdc|
|Supply voltage tolerance|±15%|±15%|±15%|
|Rated consumption|2.5 VA (2W) maximum|2.5 VA (2W) maximum|2.5 VA (2W) maximum|
|Reset time|150 ms|150 ms|150 ms|
|Reverse polarity protection|Yes|Yes|Yes|
|Operate time<br>Release time|25 ms maximum<br>25 ms maximum|25 ms maximum<br>25 ms maximum|25 ms maximum<br>25 ms maximum|
|Rated surge voltage|4 kV|4 kV|4 kV|
|**Output**||||
|Contact configuration|DPDT|SPDT|DPDT|
|Contact rating (AC)<br>Contact rating (DC)|12A resistive at 120, 240 UL 508<br>12A resistive at 30 UL 508|12A resistive at 120, 240 UL 508<br>12A resistive at 30 UL 508|12A resistive at 120, 240 UL 508<br>12A resistive at 30 UL 508|
|Contact rating horsepower|1/2 at 120 Vac, 1 at 240 Vac|1/2 at 120 Vac, 1 at 240 Vac|1/2 at 120 Vac, 1 at 240 Vac|
|Contact rating pilot duty|A300, 720 VA at 240 Vac|A300, 720 VA at 240 Vac|A300, 720 VA at 240 Vac|
|Minimum load|12V/100 mA|12V/100 mA|12V/100 mA|
|Contact material|Silver-nickel 90/10|Silver-nickel 90/10|Silver-nickel 90/10|
|Contact resistance|100 milliohms max. at 1A 12 Vdc|100 milliohms max. at 1A 12 Vdc|100 milliohms max. at 1A 12 Vdc|
|Mechanical life—full load<br>Electrical life—full load|10 million operations<br>100,000 operations|10 million operations<br>100,000 operations|10 million operations<br>100,000 operations|
|**Control Signal**||||
|Minimum control pulse length|50 ms minimum|50 ms minimum|50 ms minimum|
|**Accuracy**||||
|Repetition accuracy|0.10% at constant voltage and temperature|0.10% at constant voltage and temperature|0.10% at constant voltage and temperature|
|**Physical**||||
|Ambient temperature<br>Storage temperature|–10 to 55°C<br>–40 to 85°C|–10 to 55°C<br>–40 to 85°C|–10 to 55°C<br>–40 to 85°C|
|Mounting|Use with D3PA3 socket|Use with D3PA2 socket|Use with D3PA2 socket|
## _**Note**_
> 1 Refer to Function Code Cross-Reference Guide on **Page V7-T3-165** for function details.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-184**
Control Relays and Timers
3.8
Timing Relays
## **Wiring Diagrams**
**==> picture [349 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
TMRP5100 TMRP5101 TMRP5102<br>External Control Switch<br>4 5 4 5<br>3 6 3 6<br>5 6 7 2 7 2 7<br>4 8 1 8 1 8<br>3 9<br>2 10 INPUT INPUT<br>1 11<br>INPUT<br>External Control Switch<br>Instant if 6–7 Shorted<br>**----- End of picture text -----**<br>
**3**
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **TMRP Series**
**==> picture [383 x 191] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.88 0.06 2.83<br>(47.8) (1.5) (71.9)<br>OUTPUTINPUT R.045<br>(47.8)1.88 FUNCTION TIMESET BASETIME (44.7)1.76 8-Pin Octal Base<br>A 0 0 0 S<br>0.25 0.64<br>(6.4) (16.3)<br>3.15<br>(80.0)<br>11-Pin Octal Base<br>1 11<br>1 8<br>2 10<br>2 7<br>3 9<br>8<br>3 6<br>4<br>5 7<br>4 5<br>6<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-185**
Control Relays and Timers
3.9
Alternating Relays
**3**
## **D85 Series—Alternating Relays**
## **Product Description**
Alternating relays are used in applications where the optimization of load usage is required by equalizing the run time of two loads. They are also used where additional capacity is required in case of excess load requirements. This alternating action is initiated by a control switch— such as a float switch, manual switch, timing relay, pressure switch or other isolated contact. Each time the initiating switch is opened, the output relay contacts will change state, thus alternating the two loads. Two LED indicators show the status of the output relay.
The D851 and D852 Series Relays are used with one control switch and are available in either SPDT or DPDT output configurations with or without a selector switch to lock in one sequence. The D852X Series Relays are available in DPDT cross-wired output configurations for use with one or two control switches (LEAD and LAG).
The D853 Series is designed for use with three-switch applications (LEAD, LAG and STOP). The D853 Series combines a standard DPDT Cross-Wired alternating relay, contactor auxiliary contacts, and a control relay into one compact and economical product. This saves space and labor, while reducing the number of components needed. The D853 Series uses Sequence On– Simultaneous Off (S.O.S.O.) operation, where the two loads are energized sequentially, but remain on together until the STOP switch is opened. This device also protects against failure of the STOP and LEAD switches. If both switches fail, the two pump motors will be energized simultaneously when the LAG switch is closed.
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|D85 Series—Alternating Relays||
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-187**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-187**|
|Technical Data and Specifications . . . . . . . . . .|**V7-T3-188**|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-188**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V7-T3-190**|
## **Features**
Each of the D85 Series alternating relays is available with an optional threeposition selector switch, which allows the unit to alternate the two loads as normal, or lock the relay to one load or the other. By locking the alternating relay to one load, the other load can be removed for service without rewiring the first load for continuous operation. The selector switch has a low profile to prevent any accidental actuation.
- For duplex loads
- Works with one-, two-, or three-switch applications
- Compact plug-in design using industry standard sockets
- 10A SPDT or DPDT output configurations
- Optional low profile selector switch to lock in one sequence
- Two LEDs indicate relay status
- D853 Series replaces separate components in duplex panel—saving space and reducing labor
## **Standards and Certifications**
- CE
- cRUus
- UL listed 1
- RoHS compliant
## _**Note**_
- 1 When used with appropriate Eaton socket.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-186**
Control Relays and Timers
3.9
Alternating Relays
## **Product Selection**
## **D85 Series—Alternating Relays**[1]
|**D85 Series—Alternating Relays**|1|||
|---|---|---|---|
||**Control**||**Catalog**|
|**Output Contacts**|**Voltage**|**Socket**|**Number**|
|SPDT|12 Vac|8-pin|**D851NR**|
|SPDT|24 Vac|8-pin|**D851NT**|
|SPDT|120 Vac|8-pin|**D851NA**|
|SPDT|240 Vac|8-pin|**D851NB**|
|SPDT w/selector switch|12 Vac|8-pin|**D851LR**|
|SPDT w/selector switch|24 Vac|8-pin|**D851LT**|
|SPDT w/selector switch|120 Vac|8-pin|**D851LA**|
|SPDT w/selector switch|240 Vac|8-pin|**D851LB**|
|DPDT|12 Vac|11-pin|**D852NR**|
|DPDT|24 Vac|11-pin|**D852NT**|
|DPDT|120 Vac|11-pin|**D852NA**|
|DPDT|240 Vac|11-pin|**D852NB**|
|DPDT w/selector switch|12 Vac|11-pin|**D852LR**|
|DPDT w/selector switch|24 Vac|11-pin|**D852LT**|
|DPDT w/selector switch|120 Vac|11-pin|**D852LA**|
|DPDT w/selector switch|240 Vac|11-pin|**D852LB**|
|DPDT cross-wired|12 Vac|8-pin|**D852XNR**|
|DPDT cross-wired|24 Vac|8-pin|**D852XNT**|
|DPDT cross-wired|120 Vac|8-pin|**D852XNA**|
|DPDT cross-wired|240 Vac|8-pin|**D852XNB**|
|DPDT cross-wired w/selector switch|12 Vac|8-pin|**D852XLR**|
|DPDT cross-wired w/selector switch|24 Vac|8-pin|**D852XLT**|
|DPDT cross-wired w/selector switch|120 Vac|8-pin|**D852XLA**|
|DPDT cross-wired w/selector switch|240 Vac|8-pin|**D852XLB**|
**3**
## **Accessories**
## **D85 Series—Alternating Relays**
||**Standard**|**Catalog**|
|---|---|---|
|**Description**|**Pack**|**Number**|
|8-pin socket|10|**D3PA2**|
|11-pin socket|10|**D3PA3-A2**|
|Hold-down spring|10|**D65CHDS**|
## _**Note**_
1 Contact Eaton for relays for 3-switch applications (Lead-Lag-Stop).
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-187**
Control Relays and Timers
3.9
Alternating Relays
## **Technical Data and Specifications**
**D85 Series—Alternating Relays**
**3**
|**D85 Series—Alternating**|**Relays**|
|---|---|
|**Description**|**Specification**|
|Voltage tolerance<br>Load (burden)|+10%/-15% of control voltage at 50/60 Hz<br>Less than 3 VA|
|Output contacts<br>Mechanical life|10A resistive at 240 Vac / 30 Vdc, 1/2 hp at 120/240 Vac (NO), 1/3 hp at 120/240 Vac (NC)<br>10,000,000 operations|
|Electrical life<br>Temperature|100,000 operations<br>–20° to 150°F (–28° to 65°C)|
|Transient protection|10,000 volts for 20 microseconds|
|Indicator LEDs|2 LEDs marked LOAD A and LOAD B|
|Optional selector switch settings|ALTERNATE, LOCK LOAD A, LOCK LOAD B|
## **Wiring Diagrams**
**D851 Series Relays, SPDT**
**D852 Series Relays, DPDT**
**D852X Series Relays, DPDT Cross-Wired**
**D853 Series Relays, Three-Switch Applications**
**==> picture [499 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input Input Input Input Voltage<br>Voltage L1 Voltage L2 L1 Voltage L2 L1 Stop L2<br>L2 L1 Control Control<br>Switch Switch<br>4 5 4 5<br>23 4 5 67 34 5 6 7 89 Lag 32 1 8 67 LoadB Lag 32 1 8 67 LoadB<br>1 8 2 1 11 10 Lead Lead<br>Load A: Pin 2Load B: Pin 8 Load A: Pins 3 or 11Load B: Pins 1 or 9 LoadA LoadA<br>**----- End of picture text -----**<br>
**Typical Installations for SPDT and DPDT Alternating Relays, Standard Installation**
**==> picture [237 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L2<br>SPDT<br>1 O/L<br>2 M1<br>Control<br>Switch O/L<br>5<br>8 M2<br>4 3<br>**----- End of picture text -----**<br>
In the OFF state (standard installation), the control switch is open, the alternating relay is in the LOAD A position, and both loads (M1 and M2) are off. When the control switch closes, it energizes the first load (M1). The red LED marked “LOAD A” glows. As long as the control switch remains closed, M1 remains energized.
When the control switch opens, the first load (M1) is turned off and the alternating relay toggles to the LOAD B position. When the control switch closes again, it energizes the second load (M2). The red LED marked “LOAD B” glows.
**Typical Installations for SPDT and DPDT Alternating Relays, Anti-Bounce Installation**
**==> picture [239 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L2<br>M2<br>M2<br>M1<br>M1<br>SPDT<br>1<br>Control 2<br>Off Switch<br>5<br>8<br>4 3<br>**----- End of picture text -----**<br>
When the control switch opens, the second load (M2) is turned off, the alternating relay toggles back to the LOAD A position, and the process can be repeated again. On relays with DPDT contacts, two pilot lights can be used for remote indication of LOAD A or LOAD B status.
To eliminate any bounce condition of the control switch, the addition of a second switch (OFF) along with two auxiliary contacts is recommended as shown in the Anti-Bounce Installation.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-188**
Control Relays and Timers
3.9
Alternating Relays
**Typical Installations for DPDT Cross-Wired Alternating Relays, Standard Installation**
**==> picture [214 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L2<br>Cross-Wired<br>Lag<br>O/L<br>2<br>8 M1<br>Lead<br>1 O/L<br>7 M2<br>3 6<br>**----- End of picture text -----**<br>
In the OFF state, both the LEAD control switch and the LAG control switch are open, the alternating relay is in the LOAD A position, and both loads are off. When the LEAD control switch closes, it energizes the first load (M1). The red LED marked “LOAD A” glows. As long as the LEAD control switch remains closed, M1 remains energized. If the LAG control switch closes, it energizes the second load (M2).
When the LAG control switch opens, the second load (M2) is turned off. When the LEAD control switch opens, the first load (M1) is turned off and the alternating relay toggles to the LOAD B position.
**Typical Installations for DPDT Cross-Wired Alternating Relays, Anti-Bounce Installation**
**==> picture [211 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L2<br>M2<br>M2<br>M1<br>M1<br>Cross-Wired<br>Lag<br>2<br>8<br>Off Lead<br>1<br>7<br>3 6<br>**----- End of picture text -----**<br>
When the LEAD control switch closes, it turns on the second load (M2). The red LED marked “LOAD B” glows. If the LAG control switch closes, it will energize the first load (M1). When the LAG control switch opens, the first load (M1) is turned off. When the LEAD control switch opens, the second load (M2) is turned off, the alternating relay toggles back to the LOAD A position, and the process can be repeated again.
To eliminate any bounce condition of the control switch, the addition of a second switch (OFF) along with two auxiliary contacts is recommended as shown in the Anti-Bounce Installation.
**3**
## **Typical Installations for DPDT Cross-Wired Relays for Three-Switch Applications**
**==> picture [246 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
M1<br>L1<br>M1<br>L2 Motor<br>1<br>M1<br>L3<br>M2<br>L1<br>M2<br>L2 Motor<br>2<br>M2<br>L3<br>**----- End of picture text -----**<br>
In the OFF state, all three switches are open, the alternating relay is in the LOAD A position, and both loads are off. No action happens with the alternating relay or either load when the STOP switch closes. When the LEAD switch closes, Load #1 (M1) turns on. When the LAG switch closes, Load #2 (M2) turns on. Both loads remain on as long as all three switches are closed.
When the LAG switch opens, Load #2 (M2) remains on because the STOP switch is still closed. When the LEAD switch opens, Load #1 (M1) remains on because the STOP switch is still closed. When the STOP switch opens, both Load #1 (M1) and Load #2 (M2) are turned off simultaneously.
**==> picture [229 x 131] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lag<br>Switch<br>O/L<br>2<br>8 M1<br>Lead<br>Switch<br>O/L<br>1<br>7 M2<br>Stop<br>Switch<br>4<br>L1 3<br>L2 6<br>**----- End of picture text -----**<br>
The alternating relay toggles to the LOAD B position. The entire cycle is then repeated, but with Load #2 (M2) energized first followed by Load #1 (M1). This type of operation is known as “Sequence On–Simultaneously Off (S.O.S.O.)”—the two loads are energized sequentially, but remain on together until the STOP switch is opened.
If both the STOP switch and LEAD switch fail to close and turn on the first load, both loads will be turned on simultaneously when the LAG switch is closed.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-189**
3.9
Alternating Relays
**3**
## Control Relays and Timers
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **D85 Series—Alternating Relays**
**==> picture [241 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.4<br>(60)<br>2.9<br>(74)<br>1.7 3.1<br>(43) (79)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-190**
CA08100008E—April 2012 www.eaton.com
Control Relays and Timers
3.10
Safety Relays
## **Safety Relays**
## **Contents**
_**Description Page**_ Safety Relays **3** Product Selection . . . . . . . . . . . . . . . . . . . . . . . **V7-T3-192** Technical Data and Specifications . . . . . . . . . . **V7-T3-193 3** Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . **V7-T3-196**
## **Product Description**
Safety relays are intended to reliably monitor the signals from safety devices at all times and switch off quickly and reliably in an emergency. Single-channel and dual channel versions are available for the construction of safety applications. The internal logic of the safety relays monitors the safety circuits (emergency stop, guard door, and so on) and activates the enable paths in a fault-free condition. Upon actuation of the safety device or in the even of a fault, the enable paths are switched off. Any faults that occur in the control circuit, such as ground fault, cross connection fault or wire breakage are also detected.
## **Application Description**
Eaton’s ESR5 safety relays provide optimal safety and a high degree of reliability on plant machinery. Applications that meet the highest safety requirements in accordance with EN 954-1, EN ISO 13849-1 up to PL e and accordance with IEC 62061 up to SILCL 3 can be realized with the ESR5 safety relay.
Compatible with a wide variety of safety devices:
- Emergency stops
- Rope pulls
- Two-hand control stations
- Light curtain (OSSD)
- Gate enable device
- Safety switches
## **Standards and Certifications**
## **Features**
- Use for the highest ● UL 508; CSA-C22.2 No safety requirements in 14-95; CE Marked accordance with EN 954-1 ● UL/cUL file number: EN ISO 13849-1, E29184 IEC 62061 and EC 61508
- Degree of protection: IP20
- Suitable for the world market with UL, cUL certifications and TÜV Rhineland functional safety certifications
- TÜV Rhineland certified
- UL/cULus listed
- Applicable for EN 60204 stop categories 0 or 1
- Plug-in screw terminals for fast and fault-free replacement
- Multi-voltage versions (24–230 Vac/Vdc) for a flexible range of application
- Delayed and non-delayed contact expansions accommodate a wide variety of applications
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-191**
Control Relays and Timers
3.10
Safety Relays
## **Product Selection**
**3**
## **Technical Overview**
## **Safety Relays**
|**Safety Relays**|**Technical Overview**|**Technical Overview**|**Technical Overview**|||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|||||**Safety**||**Signal**|||**Removable**|||
||**Single**<br>**Channel**|**Dual**<br>**Channel**|**Safety**<br>**Output (NO)**|**Output (NO)**<br>**(Delayed)**|**Output**<br>**Delay**|**Output**<br>**(NC)**|**Feedback**<br>**Output**|**Control**<br>**Voltage**|**Terminal**<br>**Blocks**|**Type of**<br>**Unit**|**Catalog Number**|
|(eleelefen|■|—|4|—|—|1|—|24 Vac/Vdc|■|Main|**ESR5-NO-41-24VAC-DC**|
|i@] <br>oa<br>2TeTay|■<br>■<br>2<br>—<br>—<br>1<br>—<br>24 Vac/Vdc<br>■<br>Main<br>**ESR5-NO-21-24VAC-DC**<br>■<br>■<br>3<br>—<br>—<br>1<br>—<br>24 Vac/Vdc<br>■<br>Main<br>**ESR5-NO-31-24VAC-DC**<br>■<br>■<br>3<br>—<br>—<br>1<br>—<br>230 Vac<br>■<br>Main<br>**ESR5-NO-31-230VAC**<br> ~~a~~<br>~~mm~~|||||||||||
||■|■|3|—|—|1|—|24–230 Vac/Vdc|■|Main|**ESR5-NO-31-AC-DC**|
||■|■|2|2|0.1–30s|—|—|24 Vdc|■|Main|**ESR5-NV3-30**|
||—|■|2|—|—|1|—|24 Vac/Vdc|■|Main|**ESR5-NZ-21-24VAC-DC**|
||■<br>■|—<br>—|5<br>—|—<br>4|—<br>0.3–3s|1<br>1|1<br>1|24 Vac/Vdc<br>24 Vdc|■<br>■|Expansion<br>Expansion|**ESR5-NE-51-24VAC-DC**<br>**ESR5-VE3-42**|
## **Application Overview**
|**Emergency**|**Safety**|**Light Curtain/**|**Two-Hand Control**|**Contact**||**Cross Circuit**|**Monitored**||
|---|---|---|---|---|---|---|---|---|
|**Stop**<br>■<br>~~a~~|**Switches**<br>■<br>~~a~~|**OSSD**1<br>—<br>~~a~~|**(EN 574 Type III C)**<br>—<br>~~a~~|**Expansion**<br>—<br>~~a~~|**Off-Delayed**<br>—<br>~~a~~|**Recognition**<br>—<br>~~a~~|**Manual Reset**2<br>—<br>~~a~~|**Catalog Number**<br>**ESR5-NO-41-24VAC-DC**<br>~~a~~|
|■|■|—|—|—|—|■|—|**ESR5-NO-21-24VAC-DC**|
|■|■|—|—|—|—|■|—|**ESR5-NO-31-24VAC-DC**|
|■|■|—|—|—|—|■|■|**ESR5-NO-31-230VAC**|
|■|■|—|—|—|—|■|■|**ESR5-NO-31-AC-DC**|
|■|■|■|—|—|■|■|■|**ESR5-NV3-30**|
|—|■|—|■|—|—|■|—|**ESR5-NZ-21-24VAC-DC**|
|—|—|—|—|■|—|—|—|**ESR5-NE-51-24VAC-DC**|
|—|—|—|—|■|■|—|—|**ESR5-VE3-42**|
## **Application Overview, continued**
|**Single**|**Dual**|**Stop Category**|**Control Category**|**Achievable PL per**|**Achievable SIL per**||
|---|---|---|---|---|---|---|
|**Channel**|**Channel**|**EN 60204**|**to EN 954-1**|**ISO 13849-1**|**EN IEC 62061**|**Catalog Number**|
|■|—|0|2|PL d|SIL 3|**ESR5-NO-41-24VAC-DC**|
|■|■|0|4|PL e|SIL 3|**ESR5-NO-21-24VAC-DC**|
|■|■|0|4|PL e|SIL 3|**ESR5-NO-31-24VAC-DC**|
|■|■|0|4|PL e|SIL 3|**ESR5-NO-31-230VAC**|
|■<br>■|■<br>■|0<br>0/1|4<br>4|PL e<br>PL e|SIL 3<br>SIL 3|**ESR5-NO-31-AC-DC**<br>**ESR5-NV3-30**|
|—|■|0|4|PL e|SIL 3|**ESR5-NZ-21-24VAC-DC**|
|■|—|0|4|PL e|SIL 3|**ESR5-NE-51-24VAC-DC**|
|■|—|1|3|PL d|SIL 2|**ESR5-VE3-42**|
## _**Notes**_
1 Laser scanners or light curtains with OSSD outputs.
2 All main units can also be reset automatically or manually.
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-192**
Control Relays and Timers
3.10
Safety Relays
## **Technical Data and Specifications**
|**Safety Relay**<br>**Description**|**Unit**|**ESR5-NO-21_**|**ESR5-NO-41_**|**ESR5-NO-31-24VAC-DC**|**ESR5-NZ-21_**|
|---|---|---|---|---|---|
|**General**<br>Standards||EN ISO 13849-1, IEC 62061,|EN ISO 13849-1, IEC 62061,|EN ISO 13849-1, IEC 62061,|EN ISO 13849-1, IEC 62061,|
|||IEC 61508, DIN EN 50178,<br>UL/CUL listed|IEC 61508, DIN EN 50178,<br>UL/CUL listed|IEC 61508, DIN EN 50178,<br>UL/CUL listed|IEC 61508, DIN EN 50178,<br>UL/CUL listed|
|Type-dependent standards<br>Lifespan, mechanical—c (contacts)|x 106|—<br>10|—<br>10|—<br>10|EN 574 Part no. IIIC<br>10|
|Maximum operating frequency<br>Climatic proofing|Ops/h|3600<br>Cold according to|3600<br>Dry heat according to|3600<br>Cold according to|3600<br>Dry heat according to|
|||EN 60068-2-1, dry heat|EN60068-2-2, damp heat|EN 60068-2-1, dry heat|EN60068-2-2, damp heat|
|||according to EN60068-2-2,<br>damp heat according to|according to EN 60068-2-3|according to EN60068-2-2,<br>damp heat according to|according to EN 60068-2-3|
|Ambient temperature|°F (°C)|EN 60068-2-3<br>–4° to 131° (–20° to 55°)|–4° to 131° (–20° to 55°)|EN 60068-2-3<br>–4° to 131° (–20° to 55°)|–4° to 131° (–20° to 55°)|
|Ambient temperature storage<br>Mounting position|°F (°C)|–13° to 167° (–25° to 75°)<br>Any|–13° to 167° (–25° to 75°)<br>Any|–13° to 167° (–25° to 75°)<br>Any|–13° to 167° (–25° to 75°)<br>Any|
|Vibration resistance (IEC/EN 60068-2-6)||2g, frequency: 10–150 Hz,<br>amplitude: 0.15 mm|2g, frequency: 10–150 Hz,<br>amplitude: 0.15 mm|2g, frequency: 10–150 Hz,<br>amplitude: 0.15 mm|2 g, frequency: 10–150 Hz,<br>amplitude: 0.15 mm|
|Shock resistance (IEC 60068-2-27)<br>Protection type||—|—|—|—|
|Housing<br>Terminals||IP20<br>IP20|IP20<br>IP20|IP20<br>IP20|IP20<br>IP20|
|Protection against direct contact when<br>actuated from front (IEC 0106 Part 100)||Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|
|Weight<br>Terminal capacity|kg|0.17|0.22|0.17|0.22|
|Solid or flexible|mm2|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|
|Flexible with ferrule|mm2|1 x (0.25–2.5)|1 x (0.25–2.5)|1 x (0.25–2.5)|1 x (0.25–2.5)|
|||2 x (0.25–1)|2 x (0.25–1)|2 x (0.25–1)|2 x (0.25–1)|
|Solid or stranded|AWG|24–12|24–12|24–12|24–12|
|Terminal screw||||||
|Pozidriv screwdriver|Size|2|2|2|2|
|Flat-blade screwdriver|mm|0.6 x 3.5|0.6 x 3.5|0.6 x 3.5|0.6 x 3.5|
|Max. tightening torque|Nm|0.6|0.6|0.6|0.6|
|**Main Contacts**||||||
|Rated impulse withstand voltage—Uimp<br>Overvoltage category/pollution degree|Vac|6000|4000|4000|6000|
|Outside||III/2|III/2|III/2|III/2|
|Inside||—|—|—|—|
|Rated insulation voltage—Ui|Vac|250|250|250|250|
|Rated operating voltage—Ue|Vac|230|230|230|230|
|Rated operation current<br>AC-15||||||
|230V (360 ops./h)—Ie<br>230V (3600 ops./h)—Ie|A<br>A|5<br>3|4<br>3|5<br>3|4<br>3|
|DC-13<br>24V (360 ops./h)—Ie|A|6|4|6|4|
|24V (3600 ops./h)—Ie<br>Max. summation current of all poles|A|3|2.5|3|2.5|
|24 Vac/Vdc devices<br>230 Vac devices|A<br>A|72<br>—|72<br>—|72<br>—|72<br>—|
|Square of the total current<br>(and total current)||72 A2(6 + 6)|72 A2(4.2 + 4.2 + 4.2 + 4.2)|72 A2(4.9 + 4.9 + 4.9)|72 A2(6 + 6)|
|of all current paths||||||
|Short-circuit protection||||||
|Max. fuse|A gG/gL|10|6|10|6|
**3**
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-193**
3.10
**3**
## Control Relays and Timers
## Safety Relays
|**Safety Relay, continued**<br>**Description**|**Unit**|**ESR5-NO-21_**|**ESR5-NO-41_**|**ESR5-NO-31-24VAC-DC**|**ESR5-NZ-21_**|
|---|---|---|---|---|---|
|**Power Supply Circuit**||||||
|Actuating voltage 50/60 Hz|Vac|24|24|24|24|
|Actuating voltage—Us|Vdc|24|24|24|24|
|Voltage tolerance pick-up voltage|xe|0.85–1.1|0.85–1.1|0.85–1.1|0.85–1.1|
|Power consumption||||||
|AC operated 50/60 Hz|VA|—|—|—|—|
|AC operated 50/60 Hz|W|3.4|3.4|3.4|3|
|DC operated|W|1.6|1.6|1.6|1.5|
|Fuse for control circuit supply||||||
|24V||Short-circuit proof|Short-circuit proof|Short-circuit proof|Short-circuit proof|
|115/230V||—|—|—|—|
|**Control Circuit**||||||
|Rated output voltage|Vdc|24|24|24|24|
|Rated operational current<br>Resistance—R|mA|S12, S22: 30, S34: 45<br>50|S12: 65, S34: 40<br>22|S12, S22: 30, S34: 45<br>50|S11, S21: 60, Y2: 45<br>22|
|Short-circuit current<br>Response time|A<br>ms|2.3<br>100|2.3<br>65|2.3<br>100|2.3<br>50|
|Recovery time<br>Response time with reset monitoring—tA1|ms<br>ms|—<br>—|—<br>—|—<br>—|—<br>—|
|Response time without reset monitoring—tA2<br>Reset time—tR/tR1|ms<br>ms|100<br>Single-channel 45;|65<br>45|100<br>Single-channel 45;|50<br>20|
|Minimum on duration—tM|ms|dual-channel 10<br>—|—|dual-channel 10<br>—|—|
|Recovery time—tW<br>Synchronous monitoring time—tS|ms<br>ms|Approx. 1000<br>—|Approx. 1000<br>—|Approx. 1000<br>—|Approx. 1000<br>500|
|**Electromagnetic Compatibility (EMC)**||||||
|Emitted interference||EN 61000-6-4|EN 61000-6-4|EN 61000-6-4|EN 61000-6-4|
|Interference immunity||According to EN 61000-6-2,<br>EN 62061|According to EN 61000-6-2|According to EN 61000-6-2,<br>EN 62061|According to EN 61000-6-2|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-194**
Control Relays and Timers
3.10
Safety Relays
**3**
## **Safety Relay, continued**
|**Safety Relay, continued**|||||||
|---|---|---|---|---|---|---|
||||**ESR5-NO-31-24V-**||||
|**Description**<br>**General**|**Unit**|**ESR5-NO-31-230VAC**|**230VAC-DC**|**ESR5-NV3_**|**ESR5-VE3_**|**ESR5-NE-51_**|
|Standards||EN ISO 13849-1, IEC 62061,<br>IEC 61508, DIN EN 50178,|EN ISO 13849-1, IEC 62061,<br>IEC 61508, DIN EN 50178,|EN ISO 13849-1, IEC 62061,<br>IEC 61508, DIN EN 50178,|EN ISO 13849-1, IEC 62061,<br>IEC 61508, DIN EN 50178,|EN ISO 13849-1, IEC 62061,<br>IEC 61508, DIN EN 50178,|
|||UL/CUL listed|UL/CUL listed|UL/CUL listed|UL/CUL listed|UL/CUL listed|
|Type-dependent standards||EN 60204|EN 60204|EN 60204|—|—|
|||(if applicable)|(if applicable)|(if applicable)|||
|Lifespan, mechanical—c (contacts)|x 106|10|10|10|10|10|
|Maximum operating frequency|Ops/h|3600|3600|3600|900|3600|
|Climatic proofing||Dry heat according to|Dry heat according to|Cold in accordance with:|Dry heat according to|Dry heat according to|
|||EN60068-2-2, damp heat|EN60068-2-2, damp heat|EN 60068-2-1, dry heat in|EN60068-2-2, damp heat|EN60068-2-2, damp heat|
|||according to EN 60068-2-3|according to EN 60068-2-3|accordance with EN<br>60068-2-2, humidity|according to EN 60068-2-3|according to EN 60068-2-3|
|||||storage test in accordance|||
|||||with 60068-2-78|||
|Ambient temperature|°F (°C)|–4° to 131° (–20° to 55°)|–4° to 131° (–20° to 55°)|–4° to 113° (–20° to 45°)|–4° to 131° (–20° to 55°)|–4° to 131° (–20° to 55°)|
|Ambient temperature storage|°F (°C)|–13° to 167° (–25° to 75°)|–13° to 167° (–25° to 75°)|–13° to 167° (–25° to 75°)|–13° to 167° (–25° to 75°)|–13° to 167° (–25° to 75°)|
|Mounting position||Any|Any|Any|Any|Any|
|Vibration resistance (IEC/EN 60068-2-6)||2g, frequency: 10–150 Hz,|2g, frequency: 10–150 Hz,|2g, frequency: 10–150 Hz,|2g, frequency: 10–150 Hz,|2g, frequency: 10–150 Hz,|
|||amplitude: 0.15 mm|amplitude: 0.15 mm|amplitude: 0.15 mm|amplitude: 0.15 mm|amplitude: 0.15 mm|
|Shock resistance (IEC 60068-2-27)||—|—|—|—|—|
|Protection type|||||||
|Housing||IP40|IP40|IP20|IP20|IP20|
|Terminals||IP20|IP20|IP20|IP20|IP20|
|Protection against direct contact when<br>actuated from front (IEC 0106 Part 100)||Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|Finger- and back-of-hand<br>proof|
|Weight|kg|0.3|0.3|0.17|0.17|0.22|
|Terminal capacity|||||||
|Solid or flexible|mm2|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|1 x (0.2–2.5)<br>2 x (0.2–1)|
|Flexible with ferrule|mm2|1 x (0.25–2.5)<br>2 x (0.25–1)|1 x (0.25–2.5)<br>2 x (0.25–1)|1 x (0.25–2.5)<br>2 x (0.25–1)|1 x (0.25–2.5)<br>2 x (0.25–1)|1 x (0.25–2.5)<br>2 x (0.25–1)|
|Solid or stranded|AWG|24–12|24–12|24–12|24–12|24–12|
|Terminal screw|||||||
|Pozidriv screwdriver|Size|2|2|2|2|2|
|Flat-blade screwdriver|mm|0.6 x 3.5|0.6 x 3.5|0.6 x 3.5|0.6 x 3.5|0.6 x 3.5|
|Max. tightening torque<br>**Main Contacts**|Nm|0.6|0.6|0.6|0.6|0.6|
|Rated impulse withstand voltage—Uimp<br>Overvoltage category/pollution degree|Vac|6000|6000|4000|4000|4000|
|Outside<br>Inside||III/2<br>—|III/2<br>—|III/2<br>—|III/2<br>—|III/2<br>—|
|Rated insulation voltage—Ui<br>Rated operating voltage—Ue|Vac<br>Vac|250<br>230|250<br>230|250<br>230|250<br>230|250<br>230|
|Rated operation current<br>AC-15|||||||
|230V (360 ops./h)—Ie<br>230V (3600 ops./h)—Ie|A<br>A|4<br>3|4<br>3|—<br>3|5<br>3|4<br>3|
|DC-13|||||||
|24V (360 ops./h)—Ie|A|4|4|—|6|4|
|24V (3600 ops./h)—Ie|A|2.5|2.5|3|3|2.5|
|Max. summation current of all poles|||||||
|24 Vac/Vdc devices|A|50|50|49|50|50|
|230 Vac devices|A|50|50|—|—|—|
|Square of the total current<br>(and total current)||50 A2(4 + 4 + 4)|50 A2(4 + 4 + 4)|50 A2(4 + 4 + 4)|49 A2<br>(3.5 + 3.5 + 3.5 + 3.5)|50 A2<br>(3.7 + 3.7 + 3.7 + 3.7|
|of all current paths<br>Short-circuit protection||||||+ 3.7)|
|Max. fuse|A gG/gL|6|6|10|10|6|
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions** CA08100008E—April 2012 www.eaton.com
**V7-T3-195**
3.10
**3**
## Control Relays and Timers
## Safety Relays
## **Safety Relay, continued**
|**Safety Relay, continued**|||||||
|---|---|---|---|---|---|---|
||||**ESR5-NO-31-24V-**||||
|**Description**<br>**Power Supply Circuit**|**Unit**|**ESR5-NO-31-230VAC**|**230VAC-DC**|**ESR5-NV3_**|**ESR5-VE3_**|**ESR5-NE-51_**|
|Actuating voltage 50/60 Hz<br>Actuating voltage—Us|Vac<br>Vdc|230<br>—|24–230<br>230|—<br>24|—<br>24|24<br>24|
|Voltage tolerance pick-up voltage|xe|0.85–1.1|0.85–1.1|0.85–1.1|0.85–1.1|0.8–1.1|
|Power consumption|||||||
|AC operated 50/60 Hz<br>AC operated 50/60 Hz|VA<br>W|—<br>5.8|—<br>5.8|—<br>—|—<br>—|—<br>2.2|
|DC operated|W|2.9|2.9|1.8|2|2.2|
|Fuse for control circuit supply|||||||
|24V||—|Short-circuit proof|—|—|—|
|115/230V||Short-circuit proof|Short-circuit proof|—|—|—|
|**Control Circuit**|||||||
|Rated output voltage|Vdc|24|24|24|24|24|
|Rated operational current|mA|S10, S12, S22: 35, S34,<br>S35: 45|S10, S12, S22: 35, S34,<br>S35: 45|S12, S22: 3.5, S34, S35: 7|A1, A2: 84, K1/K2: 5|A1, A2: 92|
|Resistance—R||11|11|500|—|—|
|Short-circuit current|A|0.7|0.7|0.1|—|—|
|Response time|ms|250|250|150|20|20|
|Recovery time|ms|—|—|—|—|—|
|Response time with reset|ms|60|60|150|20|20|
|monitoring—tA1|||||||
|Response time without reset<br>monitoring—tA2|ms|250|250|150|20|20|
|Reset time—tR/tR1|ms|20|20|20 (non-delayed enable<br>paths); 100 (min. delayed|0.3–3 s (+50%)<br>adjustable|20|
|||||enable paths)|||
|Minimum on duration—tM|ms|—|—|—|—|—|
|Recovery time—tW<br>Synchronous monitoring time—tS|ms<br>ms|Approx. 1000<br>—|Approx. 1000<br>—|Approx. 330<br>—|Approx. 1000<br>—|—<br>—|
|**Electromagnetic Compatibility**<br>Emitted interference|**(EMC)**|EN 61000-6-4|EN 61000-6-4|EN 61000-6-4|EN 61000-6-4|EN 61000-6-4|
|Interference immunity||According to<br>EN 61000-6-2|According to<br>EN 61000-6-2|According to EN 61000-6-2,<br>EN 62061|According to<br>EN 61000-6-2|According to<br>EN 61000-6-2|
## **Dimensions**
Approximate Dimensions in Inches (mm)
## _**Safety Relays, Contact Expansion Modules**_
**ESR5_ 24 Vac/Vdc**
**==> picture [222 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.88<br>(22.5)<br>4.51<br>(114.5)<br>3.26 2.62 3.06 3.90<br>(82.8) (66.5) (77.6) (99.0)<br>3.74<br>0.26 (95.1)<br>(6.6)<br>**----- End of picture text -----**<br>
## **ESR5_ 230 Vac**
**==> picture [230 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.77<br>(45.0) 4.51<br>(114.5)<br>3.26 2.62 3.06 3.90<br>(82.8) (66.5) (77.6) (99.0)<br>3.74<br>0.26 (95.1)<br>(6.6)<br>**----- End of picture text -----**<br>
**Volume 7—Logic Control, Operator Interface and Connectivity Solutions**
**V7-T3-196**
CA08100008E—April 2012 www.eaton.com
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →