Image not available
Illustrative purposes only
D2E097-BK80-02
BLOWERS - CENTRIFUGAL
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EBM PAPST / PARTNER STOCK
- Product type: Blowers
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 167.76 € |
| Current stock | 10+ |
| Lead time | 30 days |
**D2E097-BK80-02** ## Operating instructions ## **ebm-papst Mulfingen GmbH & Co. KG** Bachmühle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com ## **CONTENTS** ## **1. SAFETY REGULATIONS AND NOTES** **1** 1.1 Levels of hazard warnings - 1 - 1.2 Staff qualification 1 - 1.3 Basic safety rules 1 1.4 Electrical voltage 1 - 1.5 Safety and protective functions 2 - 1.6 Mechanical movement 2 - 1.7 Emission 2 - 1.8 Hot surface 2 - 1.9 Transport 2 - 1.10 Storage 2 - 1.11 Disposal 2 ## **2. PROPER USE** **3** ## **1. SAFETY REGULATIONS AND NOTES** Please read these operating instructions carefully before starting to work with the device. Observe the following warnings to prevent malfunctions or physical damage to both property and people. These operating instructions are to be regarded as part of this device. If the device is sold or transferred, the operating instructions must accompany it. These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. ## **1.1 Levels of hazard warnings** These operating instructions use the following hazard levels to indicate potentially hazardous situations and important safety regulations: ## **DANGER** Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with the measures is mandatory. ## **WARNING** Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Exercise extreme caution while working. ## **CAUTION** - Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property. ## **NOTE** ## **3. TECHNICAL DATA** - **4** - 3.1 Product drawing 4 - 3.2 Nominal data 5 - 3.3 Technical features 5 - 3.4 Mounting data 5 3.5 Transport and storage conditions 5 ## **4. CONNECTION AND START-UP** ## **6** - 4.1 Connecting the mechanical system 6 4.2 Connecting the electrical system 6 4.3 Connection of the cables 6 - 4.4 Connection screen 7 - 4.5 Checking the connections 8 4.6 Switch on device 8 4.7 Switching off the device 8 ## **5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 8 CAUSES AND REMEDIES** - 5.1 Cleaning 9 9 - 5.2 Safety test - A potentially harmful situation can occur and, if not avoided, can lead to property damage. ## **1.2 Staff qualification** The device may only be transported, unpacked, installed, operated, maintained and otherwise used by abled, qualified, trained and authorised technical staff. Only authorised specialists are permitted to install the device, to carry out a test run and to perform work on the electrical installation. ## **1.3 Basic safety rules** Any safety hazards stemming from the device must be re-evaluated once it is installed in the end device. Observe the following when working on the unit: - ; Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. ## **1.4 Electrical voltage** - ; Check the electrical equipment of the device at regular intervals, refer to chapter 5.2 Safety test. - ; Replace loose connections and defective cables immediately. ## **DANGER** **Electrical load on the device** - Risk of electric shock - →Stand on a rubber mat if you are working on an electrically charged device. ## **WARNING** **Terminals and connections have voltage even with a unit that is shut off** Electric shock - →Wait five minutes after disconnecting the voltage at all poles before opening the device. Item no. 11320-5-9970 · Revision 75315 · Release 2014-04-09 · Page 1 / 9 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com **D2E097-BK80-02** ## Operating instructions ## **CAUTION** ## **In the event of failure, there is electric voltage at the rotor and impeller** The rotor and impeller are base insulated. - →Do not touch the rotor and impeller once they are installed. ## **CAUTION** ## **The motor restarts automatically when operating voltage is applied, e.g. after a power failure.** ## **1.8 Hot surface** ## **CAUTION** ## **High temperature at the motor housing** Danger of burn injuries →Ensure that sufficient protection against accidental contact is provided. ## **1.9 Transport** Danger of injury - →Keep out of the danger zone of the device. - →When working on the device, switch off the mains supply voltage and secure the latter from being switched on again. - →Wait until the device stops. ## **1.5 Safety and protective functions** ## **DANGER** - **Missing safety device and non-functioning safety device** If there is no safety device, you could be seriously injured, for example if you reach into the running device or your hands are sucked into it. - →Operate the device only with a fixed and isolating safety protection and a fixed guard grille. The guard must withstand the kinetic energy of a fan blade detaching at maximum speed. - →The device is a built-in component. You, the owner/ operator, are responsible for providing adequate protection for the device. - →Shut down the device immediately if you detect a missing or ineffective protective feature. ## **NOTE** ## **Transport of device** - →Transport the device in its original packaging only. - →Secure the device so that it does not slip, e.g. by using a clamping strap. ## **1.10 Storage** - ; Store the device, partially or fully assembled, in a dry and weatherproof manner in the original packing in a clean environment. - ; Protect the device from environmental impacts and dirt until the final installation. - ; We recommend storing the device for a maximum up to one year to guarantee proper operation and longest possible service life. - ; Even devices explicitly suited for outdoor use are to be stored as described prior to being commissioned. - ; Maintain the storage temperature, see chapter 3.5 Transport and storage conditions. ## **1.11 Disposal** When disposing of the device, please comply with all relevant requirements and regulations applicable in your country. ## **1.6 Mechanical movement** ## **DANGER** ## **Rotating device** Body parts that come into contact with the rotor and impeller can be injured. - →Secure the device against accidental contact. - →Before working on the system/machine, wait until all parts have come to a standstill. ## **WARNING** ## **Rotating device** Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured. - →Do not wear any loose clothing or jewellery while working on rotating parts. - →Protect long hair by wearing a cap. ## **1.7 Emission** ## **WARNING** **Depending on the installation and operating conditions, a sound pressure level greater than 70 dB(A) may arise.** Danger of noise-induced hearing loss - →Take appropriate technical safety measures. - →Protect operating personnel with appropriate safety equipment, e.g. hearing protection. - →Also observe the requirements of local agencies. Item no. 11320-5-9970 · Revision 75315 · Release 2014-04-09 · Page 2 / 9 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com **D2E097-BK80-02** ## Operating instructions ## **2. PROPER USE** The device is exclusively designed as a built-in device for moving air according to its technical data. Any other or secondary use is deemed improper and constitutes a misuse of the device. Installations on the customer's side must meet the mechanical, thermal and service life-related stresses that can occur. ## **Proper use also includes:** - Moving air with a density of 1.2 kg/m³. - Using the device in accordance with the permitted ambient temperature, see chapter 3.5 Transport and storage conditions and chapter 3.2 Nominal data. - Operating the device with all protective features in place. - Minding the operating instructions. ## **Improper use** Using the device in the following ways is particularly prohibited and may cause hazards: - Operating the device with an imbalance, e.g. caused by dirt deposits or icing. - Moving air that contains abrasive particles. - Moving highly corrosive air, e.g. salt spray mist. Exceptions are devices that are intended for salt spray mist and protected accordingly. - Moving air that contains dust pollution, e.g. suctioning off saw dust. - Operating the device close to flammable materials or components. - Operating the device in an explosive atmosphere. - Using the device as a safety component or for taking on safetyrelated functions. - Operation with completely or partially disassembled or modified protective features. - In addition, all application options that are not listed under proper use. > Item no. 11320-5-9970 · Revision 75315 · Release 2014-04-09 · Page 3 / 9 ) ebmpapst ~~2~~ ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com **D2E097-BK80-02** ## Operating instructions ## **3. TECHNICAL DATA** ## **3.1 Product drawing** All measures have the unit mm. **1** Connection line PVC 4G 0.5 mm², 4 x brass lead tips crimped Item no. 11320-5-9970 · Revision 75315 · Release 2014-04-09 · Page 4 / 9 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com **D2E097-BK80-02** ~~rs~~ ## Operating instructions For cyclic speed loads, note that the rotating parts of the device are designed for maximum one million load cycles. If you have specific questions, contact ebm-papst for support. ## **3.2 Nominal data** ||**3.2 Nominal data**|**3.2 Nominal data**|**3.2 Nominal data**|**3.2 Nominal data**|For cyclic speed loads, note that the rotating parts of the device|For cyclic speed loads, note that the rotating parts of the device| |---|---|---|---|---|---|---| ||**3.2 Nominal data**<br>**Motor**<br>M2E052-BF<br>~~>~~||||For cyclic speed loads, note that the rotating parts of the device<br>are designed for maximum one million load cycles. If you have<br>specific questions, contact ebm-papst for support.<br> 0|| |||**Phase**|1~||**3.4 Mounting data**|| |||**Nominal voltage / VAC**<br>**Frequency / Hz**|230<br>50||For depth of screw, see chapter 3.1 Product drawing|| |**Type of data definition**<br>fa<br>**Valid for approval /**<br>**standard**<br>CE<br>**Speed / min-1**<br>1750<br>**Power input / W**<br>77<br>**Current draw / A**<br>0.34<br>**Motor capacitor /µF**<br>2<br>**Capacitor voltage / VDB**<br>400<br>**Capacitor standard**<br>P0(CE)<br>**Min. backpressure / Pa**<br>0<br>**Min. ambient temperature**<br>**/ °C**<br>-25<br>**Max. ambient**<br>**temperature**<br>**/ °C**<br>30<br>**Starting current / A**<br>0.36<br>ml = Max. load · me = Max. efficiency · fa = Running at free air<br>cs = Customer specs · cu = Customer unit<br>; Secure the mounting screws against accidentally coming loose (e.g.<br>by using self-locking screws).<br>**Strength class for**<br>**mounting screws**<br>8.8<br>You can obtain additional mounting data from the product drawing if<br>necessary.<br>**3.5 Transport and storage conditions**<br>; Use the device in accordance with its protection type.<br>**Max. permissible**<br>**ambient motor temp.**<br>**(transp./ storage)**<br>+ 80 °C<br>**Min. permissible**<br>**ambient motor temp.**<br>**(transp./storage)**<br>- 40 °C<br>~~ee~~<br>~~==—~~||||||| ||Subject to alterations|||||| ||**3.3 Technical features**|||||| |||**Mass**|1.45 kg|||| |||**Size**|97 mm|||| |||**Surface of rotor**|Uncoated|||| |||**Material of impeller**|Sheet steel,hot-galvanised|||| |||**Housing material**|Sheet steel,hot-galvanised|||| |||**Motor suspension**|Motor mounted via brackets on one side|||| |||**Direction of rotation**|Counter-clockwise,seen on rotor|||| |||**Type ofprotection**|IP 20|||| |||**Insulation class**|"B"|||| |||**Mounting position**|Any|||| |||**Condensate discharge**|None|||| |||**holes**<br>**Operation mode**<br>**Motor bearing**<br>**Touch current acc.**<br>**IEC 60990 (measuring**<br>**network Fig. 4, TN**<br>**system)**<br>**Motor protection**<br>**Protection class**<br>**Product conforming**<br>**to standard**|S1<br>Ball bearing<br>< 0.75 mA<br>Thermal overload protector (TOP) wired<br>internally<br>I (if protective earth is connected by<br>customer)<br>EN 60335-1; CE|||| Item no. 11320-5-9970 · Revision 75315 · Release 2014-04-09 · Page 5 / 9 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com **D2E097-BK80-02** ## Operating instructions ## **4. CONNECTION AND START-UP** ## **4.1 Connecting the mechanical system** ## **CAUTION** ## **Cutting and crushing hazard when removing the blower from the packaging** - →Carefully remove the blower from its packaging, only touching the housing. Make sure to avoid any shock. - →Wear safety shoes and cut-resistant safety gloves. - ; Check the device for transport damage. Damaged devices must no longer be installed. - ; Install the undamaged device according to your application. ## **4.2 Connecting the electrical system** ## **DANGER** ## **Electric voltage on the device** Electric shock - →Always install a protective earth first. - →Check the protective earth. ## **DANGER** ## **Incorrect insulation** Risk of fatal injury from electric shock - →Use only cables that meet the specified installation requirements for voltage, current, insulation material, load etc. - →Route cables such that they cannot be touched by any rotating parts. ## **CAUTION** ## **Electrical voltage** The device is a built-in component and features no electrically isolating switch. cable cross-section is at least AWG26/0.13 mm². ## **Earth wire contact resistance in accordance with EN 60335** Compliance with the impedance specifications in accordance with EN 60335 for the protective earth circuit must be verified in the end application. Depending on the installation situation, it may be necessary to install an additional protective earthing conductor via the additional protective earth connection point available on the device. ## **4.2.2 Voltage control** - With open loop speed control using transformers or electronic voltage regulators (e.g. phase angle control), excessive current may occur. In addition, noises can occur with phase angle control depending on the mounting situation. ## **4.2.3 Frequency inverter** Please use a frequency converter only after consultation with ebm-papst. - Fit sinusoidal filters that work on all poles (live-live and liveearth) between the frequency inverter and the motor for operation with frequency inverters. - Depending on how the device is installed, noises may occur. Heating of the motor due to use of a frequency converter must be checked in the application by the customer. ## **4.3 Connection of the cables** External leads are brought out of device. - ; First connect the "PE" (protective earth) connection. - Connect the lines according to your application. When doing so, observe chapter 4.4 Connection screen. - →Connect the device only to circuits that can be switched off using an all-pole disconnecting switch. - →When working on the device, you must switch off the system/machine in which the device is installed and secure it from being switched on again. ## **NOTE** ## **Water penetration into leads or wires** Water enters at the cable end on the customers side and can damage the device. - →Make sure that the cable end is connected in a dry environment. - Connect the device only to circuits that can be switched off using an all-pole disconnecting switch. ## **4.2.1 Prerequisites** - ; Check whether the data on the type plate agree with the connection data and the data of the operating capacitor. - ; Before connecting the device, ensure that the supply voltage matches the operating voltage of the device. - ; Only use cables designed for current according to the type plate. For determining the cross-section, follow the basic principles in accordance with EN 61800-5-1. The protective earth must have a cross-section equal to or greater than the outer conductor crosssection. We recommend the use of 105°C cables. Ensure that the minimum Item no. 11320-5-9970 · Revision 75315 · Release 2014-04-09 · Page 6 / 9 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com **D2E097-BK80-02** ## Operating instructions ## **4.4 Connection screen** |**U1**|blue| |---|---| |**Z**|brown| |**U2**|black| |**PE**|green/yellow| Item no. 11320-5-9970 · Revision 75315 · Release 2014-04-09 · Page 7 / 9 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com **D2E097-BK80-02** ## Operating instructions ## **4.5 Checking the connections** - ; Make sure that the power is off (all phases). - ; Secure it from being switched on again. - ; Check the correct fit of the connection lines. ## **4.6 Switch on device** The device may only be switched on if it has been installed properly and in accordance with its intended use, including the required safety mechanisms and professional electrical connection. This also applies for devices which have already been equipped with plugs and terminals or similar connectors by the customer. **WARNING Hot motor housing** Fire hazard - →Ensure that no combustible or flammable materials are located close to the blower. - ; Inspect the device for visible external damage and the proper function of the protective features before switching it on. - ; Check the air flow paths of the fan for foreign objects and remove any that are found. - ; Apply the nominal voltage to the voltage supply. ## **4.7 Switching off the device** - ; Disconnect the device from the supply voltage at the main switch for the supply line. - ; When disconnecting, be sure to disconnect the earth wire connection last. ## **5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES** Do not perform any repairs on your device. Return the device to ebmpapst for repair or replacement. **WARNING Terminals and connections have voltage even with a unit that is shut off** Electric shock - →Wait five minutes after disconnecting the voltage at all poles before opening the device. ## **CAUTION** **Electrical load on the capacitor after device is switched off** Electric shock, risk of injury - →Discharge the capacitors before working on the device. ## **CAUTION** **The motor restarts automatically when operating voltage is applied, e.g. after a power failure.** Danger of injury - →Keep out of the danger zone of the device. - →When working on the device, switch off the mains supply voltage and secure the latter from being switched on again. - →Wait until the device stops. - If the device remains out of use for some time, e.g. when in storage, we recommend switching the device on for at least two hours to allow any condensate to evaporate and to move the bearings. |the bearings.||| |---|---|---| |**Malfunction/error**|**Possible cause**|**Possible remedy**| |**Impeller running**<br>**roughly**|Imbalance in rotating<br>parts|Clean the device; if<br>imbalance is still<br>evident after<br>cleaning, replace the<br>device.<br>If you have<br>attached any weight<br>clips during cleaning,<br>make sure to<br>remove them<br>afterwards.| |**Motor does not turn**|Mechanical blockage|Switch off, de-<br>energise, and<br>remove mechanical<br>blockage.| ||Mains supply<br>voltage faulty|Check mains supply<br>voltage,<br>restore power<br>supply.| ||Faulty connection|De-energise, correct<br>connection, see<br>connection diagram.| ||Thermal overload<br>protector responded|Allow motor to cool<br>off, locate and rectify<br>cause of error, if<br>necessary cancel<br>restart lock-out| Item no. 11320-5-9970 · Revision 75315 · Release 2014-04-09 · Page 8 / 9 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com **D2E097-BK80-02** ## Operating instructions ||Unacceptable<br>operating point|Check operating point| |---|---|---| |**Overtemperature of**<br>**motor**|Ambient temperature<br>too high|Lower ambient<br>temperature ifpossible| ||Insufficient cooling|Improve cooling| If you have any other problems, contact ebm-papst. ## **5.1 Cleaning** **NOTE Damage to the device during cleaning.** Malfunction possible - →Do not clean the device using a water jet or high-pressure washer. - →Do not use any cleaners containing acids, bases or solvents. - →Do not use any pointed or sharp-edged objects to clean. ## **5.2 Safety test** |**5.2 Safety test**|||| |---|---|---|---| |**What has to**<br>**be tested?**|**How to test?**|**Frequency**|**Which**<br>**measure?**| |Check the<br>protective<br>casing against<br>accidental<br>contact for<br>damage and to<br>ensure that it is<br>intact|Visual inspection|At least every<br>6 months|Repair or<br>replacement of<br>the device| |Check the<br>device for<br>damage to<br>blades and<br>housing|Visual inspection|At least every<br>6 months|Replacement<br>of the device| |Mounting the<br>connection lines|Visual inspection|At least every<br>6 months|Fasten| |Mounting of<br>protective<br>earth connection|Visual inspection|At least every<br>6 months|Fasten| |Check the<br>insulation of<br>the wires for<br>damage|Visual inspection|At least every<br>6 months|Replace wires| |Impeller for<br>wear/deposits/<br>corrosion and<br>damage|Visual inspection|At least every<br>6 months|Clean or<br>replace impeller| Item no. 11320-5-9970 · Revision 75315 · Release 2014-04-09 · Page 9 / 9 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →