Image not available
Illustrative purposes only
CX380D5
SOLID STATE RELAY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA-CRYDOM / PARTNER STOCK
- Product type:
- SVHC: To Be Advised
- Product Range: CX Series
| Delivery and price | |
|---|---|
| Units per pack | 9 |
| Price | 31.83 € |
| Current stock | 1000+ |
| Lead time | 30 days |
## **| CX SERIES** ## PCB MOUNT SOLID STATE RELAYS ## Features - SIP SSR - Ratings of 5 A @ 660 VAC - SCR output for heavy industrial loads - AC or DC control - Zero-crossing (resistive loads) or random-fire (inductive loads) output - CE Compliant to EN60950-1 ## **PRODUCT SELECTION** |**Control Voltage**|**5 A**|**5 A**|**5 A**| |---|---|---|---| |**3-15 VDC**|CX240D5||| |**4-15 VDC**|~~|~~|CX380D5<br>~~|~~<br>~~|~~|CX480D5<br>~~|~~<br>~~|~~<br>~~|~~| |**15-32 VDC**|CXE240D5|CXE380D5|CXE480D5| |**18-36 VAC**|CXE240A5<br>~~|~~|~~|~~<br>~~|~~|~~|~~<br>~~|~~<br>~~|~~| |**90-140 VAC**|CX240A5||| Page 1 Copyright © 2023 Sensata Technologies, Inc. www.sensata.com ## **SPECIFICATIONS** ## Output[(1)] **==> picture [541 x 251] intentionally omitted <==** **----- Start of picture text -----**<br> Description CX240x5 CX380x5 CX480x5<br>Operating Voltage (47-63Hz) [Vrms] 12-280 48-530 48-660<br>Transient Overvoltage [Vpk] 600 1200 1200<br>Maximum Off-State Leakage Current @<br>0.1 0.1 0.1<br>Rated Voltage [mArms]<br>Minimum Off-State dv/dt @ Maximum<br>500 500 500<br>Rated Voltage [V/μsec] [2]<br>Maximum Load Current [Arms] 5 5 5<br>Minimum Load Current [Arms] 0.06 0.06 0.06<br>Maximum Surge Current (16.6msec) [Apk] 250 250 250<br>Maximum On-State Voltage Drop @ Rated<br>1.4 1.4 1.4<br>Current [Vpk]<br>Maximum I² t for Fusing (8.3msec) [A² sec] 260 260 260<br>Minimum Power Factor (at Maximum load) 0.5 0.5 0.5<br>HP rating UL 508/IEC60947[HP/KW]: 240VAC 0.25/0.18 0.25/0.18 0.25/0.18<br>HP rating UL 508/IEC60947[HP/KW]: 380VAC NA 0.33/0.25 0.33/0.25<br>HP rating UL 508/IEC60947[HP/KW]: 480VAC NA NA 0.5/0.37<br>**----- End of picture text -----**<br> ## Input[(1)] **==> picture [541 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> Description CX240Dx CX380/480Dx CXExxxDx CX240A5 CXE240A5<br>Nominal Voltage 5 VDC 5 VDC 24 VDC 120 VAC 24 VAC<br>Control Voltage Range 3-15 VDC 4-15 VDC 15-32 VDC 90-140 VAC 18-36 VAC<br>Minimum Turn-On Voltage 3.0 VDC 4.0 VDC 15.0 VDC 90.0 Vrms 18.0 Vrms<br>Drop Out Voltage 1.0 VDC 1.0 VDC 1.0 VDC 10.0 Vrms 2.0 Vrms<br>Typical Input Current 15 mAdc 15 mAdc 15 mAdc 10mArms 10mArms<br>Nominal Input Impedance 300 Ohm 240 Ohm 1500 Ohm 14.1K Ohm 2.1K Ohm<br>Maximum Turn-On Time [msec] [3] 1/2 Cycle 1/2 Cycle 1/2 Cycle 10 10<br>Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle 40 40<br>**----- End of picture text -----**<br> ## General[(1)] **==> picture [541 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> Description Parameters<br>Dielectric Strength, Input/Output (50/60Hz) 4000 Vrms<br>Minimum Insulation Resistance (@ 500 10 [9] Ohm<br>VDC)<br>Maximum Capacitance, Input/Output 10 pF<br>Ambient Operating Temperature Range -10°C to 80°C<br>Ambient Storage Temperature Range -10°C to 125°C<br>Weight (typical) 0.4 oz (11g)<br>Encapsulation Thermally Conductive Epoxy<br>Enclosure and PCB Meets the requirements of IEC60335-1<br>**----- End of picture text -----**<br> Page 2 Copyright © 2023 Sensata Technologies, Inc. www.sensata.com **WIRING DIAGRAMS** **==> picture [437 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> TRIGGER TRIGGER<br>CIRCUIT CIRCUIT<br>AC/DC<br>Converter<br>4 3 2 1 4 3 V2 1<br>-DC +DC AC AC<br>B A B A<br>AC AC AC AC<br>Load can be wired in location A or B<br>LOAD LOAD LOAD LOAD<br>**----- End of picture text -----**<br> ## **MECHANICAL SPECIFICATIONS** Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] ## **THERMAL DERATE INFORMATION** **==> picture [200 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> 6.0<br>5.0<br>4.0<br>3.0<br>2.0<br>1.0<br>0<br>20 40 60 80<br>Ambient Temperature (ºC)<br>Load Current (Amps)<br>**----- End of picture text -----**<br> Page 3 Copyright © 2023 Sensata Technologies, Inc. www.sensata.com **ORDERING OPTIONS** Example : CXE240D5R We **CX - E - 240 - D - 5 - R** ~~— EJ — — — LI~~ **Series** _| **CX Control Voltage** esee **Blank:** 3-15 VDC (240 and D suffix only) 4-15 VDC (380/480 and D suffix only) 90-140 VAC (A suffix only) **E:** 15-32 VDC (D suffix only) 18-36 VAC (A suffix only) **Operating Voltage** pf **240:** 12-280 VAC **380:** 48-530 VAC **480:** 48-660 VAC **Control Input Type D:** DC Input **A:** AC Input **Operating Rating 5:** 5 Amps **Switching Mode** **Blank:** Zero Voltage Turn-On **R:** Random Turn-on ~~:~~ Required for valid part number For options only and not required for valid part number ## **GENERAL NOTES** ~~@~~ (1) All parameters at 25°C unless otherwise specified (2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (3) Turn-On time for random turn-on versions is 0.01 msec (DC control Models) ## **AGENCY APPROVALS & CERTIFICATIONS** @ Designed in accordance with the requirements of IEC 62314 CE EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7 IEC60335-1: Resistance to heat and fire meets the requirements of section 30, evaluated by TUV SUD. Glow Wire Test, per requirements of IEC/EN 60695-2-10 and IEC/EN 60695-2-11 Ball Pressure Test, per requirements of IEC/EN 60695-10-2 **==> picture [241 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> E116949<br>LR 81689 (DC Control only)<br>**----- End of picture text -----**<br> Page 4 Copyright © 2023 Sensata Technologies, Inc. www.sensata.com **WARNINGS** ## RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** ## HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com. SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY, AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (877) 502 5500 – Option 2 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA Page 5 www.sensata.com Rev. 04/01/21 ECN 21039 FDE-07-01 Rev. B Copyright © 2023 Sensata Technologies, Inc.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →