CW9Z-CN1M
Cable, Flush Silhouette Touchless Switches, 1 m, 22 AWG, CW Series
- Manufacturer: IDEC
- Product type: Industrial Switch Accessories
- SVHC: No SVHC (15-Jan-2019)
- For Use With: IDEC CW Series Flush Silhouette Touchless Switches
- Product Range: CW Series
- Accessory Type: Cable
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 10.14 € |
| Current stock | 10+ |
| Lead time | 30 days |
ø22 CW Series Flush Silhouette Touchless Switches CW1H/CW4H ## Touchless Switches For indoor and outdoor use Suitable for hygiene protection ~~-)~~ APEM an IDEC company ## Touchless switches suitable for both indoor and outdoor use Plastic Degree of protection: IP65/67 suitable for outdoor use UL Type 4X (Outdoor) approved. Features weather-resistant material. Output and standby status feedback by LED illumination in two colors that can be externally controlled. Blue / Pure White color variation (made-to-order product) Color combination that can be recognized by majority of people regardless of individual differences in color vision. 2 The need for touchless switches to minimize the spread of viruses is increasing. The risk is especially high when an unspecified number of people touch the same surface. Touchless switches can be used in a wide range of applications to reduce the risk of contamination. ## Metal ## Sensing range (standard model) ## Standard model (diffuse reflective) **==> picture [163 x 39] intentionally omitted <==** **----- Start of picture text -----**<br> Approx. 270mm<br>Sensitivity Approx.<br>control 70 mm<br>**----- End of picture text -----**<br> Near-infrared reflectance. Hand detection distance adjustable from approx. 70 to 270mm. (*1) Suitable for applications that require a long range detection. *1) Sensing object: Human hand. See page 6 for "Detection distance range by object" for objects other than hands. Sensitivity control available for standard models only) ## Available soon ## Short range detection model (convergent reflective) ## Sensing range (short range detection model) **==> picture [49 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Approx. 5 to 30mm<br>**----- End of picture text -----**<br> Emits and receives light at an angle. Detects objects only within a specific distance range Sensing range approx. 5 to 30mm. Suitable for applications that require only short range detection. Avoids long range detection. Models with time delay available to prevent malfunction. *PNP models only **==> picture [161 x 76] intentionally omitted <==** **----- Start of picture text -----**<br> Hand near Hand far<br>ON<br>0.5 sec 2 sec<br>OFF<br>With timer<br>**----- End of picture text -----**<br> 3 Application Examples Public areas where unspecified number of people touch the same surface Public facilities ~~Mie~~ Elevators O00 0000 Reduces the risk of viruses and bacteria spreading in applications with frequent access. **==> picture [200 x 310] intentionally omitted <==** **----- Start of picture text -----**<br> Locations requiring hygiene measures<br>Air shower<br>Food machinery<br>As direct contact is not required, touchless switches can be<br>used in applications that minimize the spread of viruses.<br>**----- End of picture text -----**<br> **==> picture [198 x 27] intentionally omitted <==** **----- Start of picture text -----**<br> Locations requiring weather resistance<br>and durability<br>**----- End of picture text -----**<br> **==> picture [207 x 278] intentionally omitted <==** **----- Start of picture text -----**<br> Parking garages<br>ee<br>Parking ticket machines<br>|IFs<br>For use in a variety of applications, both indoors and outdoors.<br>**----- End of picture text -----**<br> **==> picture [188 x 310] intentionally omitted <==** **----- Start of picture text -----**<br> Frequently operated equipment<br>Machine equipment<br>Picking<br>Reduces operation fatigue when operating buttons and<br>improves switch life.<br>**----- End of picture text -----**<br> 4 ø22 CW Series Flush Silhouette Touchless Switches CW1H/CW4H ## Touchless switches reduce risk in public and shared spaces. - Suitable for indoor and outdoor use - Adjustable detection distance - Two-color LED illumination enables identification of output and standby - See website for details on approvals and standards. ## General Specifications |Control output|Control output|Non-contact (photoMOS relay) output<br>Load power supply voltage: 24V DC± 10% max.<br>(Load current: 100mA max.)<br>Voltage drop: 1.0V max. (Load current: 100mA max.)| |---|---|---| |Protection circuit||Voltage drop: 1.0V max. (Load current: 100mA max.)<br>Power supplyreverse connectionprotection| |Response time||ppyp<br>Turn-on ≤ 2.5ms,turn-off ≤ 1ms| |Delay<br>time|On-delay|0.5 ± 0.1s(with timer model)| ||Off-delay|2.0 ± 0.1s(with timer model)| |Materials|Bezel /<br>Main body|Black plastic :PA66<br>Metal: Aluminum alloy| ||Lens|PMMA| |Degree of protection||IP65/67, UL Type 4X (OUTDOOR USE)<br> *Front of the panel| |Weight||CW1H: 15gCW4H: 20g| |Operating temperature|When in use: -25 to +55°C<br>When storing: -35 to +70°C (no freezing)| |---|---| |Operating humidity|When in use: 35 to 95%RH<br>When storing: 35 to 95%RH (no condensation)<br>Diffuse reflection method| |Detection method|Diffuse reflection method| |Adjustable range of<br>maximum detection<br>distance|120 to 350mm<br>(White drawing paper 200 x 200mm square)<br>Approx. 70 to 270mm if the object is a hand<br>(reference value)| |Light source|Infrared LED| |Rated voltage|12 to 24V DC Allowable ripple rate ±10%| |Current draw|40mA maximum (main circuit)<br>20mA maximum (illumination part)| ## CW1H/CW4H Package Quantity: 1 |Name|Shape|Sensing method|Bezel specification|Illumination color<br>(LIGHT1 / LIGHT2)|Illumination<br>control method|Timer|Part No.| |---|---|---|---|---|---|---|---| |CW Series<br>Touchless Switches||Diffuse-reflective<br>~~|~~|Black plastic<br>~~|~~|Green / Red|PNP|Without<br>timer|CW1H-DM1NGR-C| ||||||NPN||CW1H-DM1NGR-C-N| ||||||PNP|With timer|CW1H-DM1TGR-C| |||||Blue / Pure white<br>|PNP|Without<br>timer<br>|CW1H-DM1NSPW-C| ||||||NPN<br>||CW1H-DM1NSPW-C-N<br>~~=~~| ||||Metal<br>~~|eS~~|Green / Red<br>~~eS~~|PNP<br>~~eS~~|Without<br>timer<br>~~eS~~|CW4H-DM1NGR-C<br>~~eS=~~| ||||||NPN<br>~~eS~~||CW4H-DM1NGR-C-N<br>~~eS=~~| ||||||PNP<br>~~eS~~|With timer<br>~~eS~~|CW4H-DM1TGR-C<br>~~eS=~~| |||||Blue / Pure white<br>~~eS~~|PNP<br>~~eS~~|Without<br>timer<br>~~eS~~|CW4H-DM1NSPW-C<br>~~eS=~~| ||||||NPN<br>~~eS~~||CW4H-DM1NSPW-C-N<br>~~eS=~~| • Dedicated cable for external connection is not supplied. (One each of locking ring and rubber washer is supplied) ## Accessories Package Name Shape Description Part No. Ordering No. Remarks Quantity CW9Z-CN200 200mm Semistripped Cable for 1 external AWG22 CW9Z-CN CW9Z-CN500 500mm connection 10 Cable length L (9.7) CW9Z-CN1M 50 1000mm 2.0 (*1) ~~2~~ Locking ring Polyamide CW9Z-LN CW9Z-LNPN05 1 ~~Se~~ — Resin (black) (5 pcs) ~~—OO~~ Rubber 1 For waterproofing between the t 0.5 Nitrile rubber CW9Z-WM CW9Z-WMPN10 mounting panel and the main body. washer (10 pcs) • Used to attach the unit to the panel. • Weight: Approx. 150g Locking ring 110 Metal (brass) MW9Z-T1 MW9Z-T1 1 wrench Sh ~~eens~~ *1) Made-to-order product *2) Contact IDEC for lengths other than 200mm, 500mm, and 1000mm. 5 ~~DEC~~ ø22 CW Series Flush Silhouette Touchless Switches CW1H/CW4H ## Nameplates **==> picture [492 x 178] intentionally omitted <==** **----- Start of picture text -----**<br> Name / Shape Description Part No. Ordering No. Package Quantity Remarks<br>ee Me es Pn tr<br>Nameplate • Marking plate HWNP (sold separately) is required.<br>CWAM • Degree of protection: IP65 2927 2.7<br>Legend • Attach the nameplate<br>Without Plastic with the switch actuator<br>CWAM CWAM 1<br>marking (Black) rubber washer attached.<br>plate<br>e a Bet aaa<br>7 0.7<br>i Oy |<br>Marking plate • White letters on black background<br>HWNP (*1) (*2) HWNP- 1 • Engraving area: W25 H7. 27<br>Aluminum i<br>HWNP- <br>(Black)<br>1<br>HWNP- PN10<br>= Photo: HWNP-35 lm (10 pcs) t=1.0mm<br>*1) Available in units of 1 piece, but standard prices vary.<br>*2) Specify the legend code below in place of in the part number.<br>ø22.2<br>12.1<br>30<br>14<br>12<br>**----- End of picture text -----**<br> ## Legend for marking plate |Code|Legend<br>Code|Code|Legend| |---|---|---|---| |0|Blank|4<br>STOP|STOP| |1|ON|31<br>OFF-ON|OFF-ON| |2|OFF|35<br>HAND-AUTO|HAND-AUTO| |3|START|53<br>HAND-OFF-AUTO|HAND-OFF-AUTO| ## Dimensions All dimensions in mm. ## Mounting Hole Layout All dimensions in mm. ## Main body **==> picture [486 x 347] intentionally omitted <==** **----- Start of picture text -----**<br> 2 35<br>Sensitivity control<br>Projector/receiver 16<br>center TOP<br>— iis ta<br>M22 P:1.0<br>3<br>Illumination part Rubber washer 7 Locking ring Connector for external connection — sp or t i<br>30<br>IEC60947-5-1 compliant<br>• Determine mounting centers to ensure easy<br>operation.<br>Characteristics<br>Detection area Detection distance range by object<br>450<br>50 Sensitivity volume<br>400 Max. Min.<br>40<br>30 Os 350 ———<br>20 Aes Sensitivity control (maximum) 300 oe<br>10 250<br>0 Sensitivity control (minimum)<br>200<br>-10<br>150<br>-20 ee<br>100<br>-30 Y<br>-40 X 50<br>Object: 200mm ×200mm White matte paper<br>-50 pSSR aseeon 0 omenPLATE s lH E SosoHIS =<br>0 50 100 150 200 250 300 350 400 450 Palm of Index White Black Polyethylene Natural rubber Synthetic Synthetic<br>Sensing distance X (mm) the hand finger paper paper gloves gloves (white) rubber (white) rubber (blue)<br>• Detection distance measured using the actual object (using gloves).<br>ø28 ø22.3 0.0+0.4<br>5.5<br>50<br>ø28 ø20.4<br>Sensing position Y (mm) Sensing distance (mm)<br>**----- End of picture text -----**<br> ## Characteristics ## Detection area - 200×200mm white and black paper used. 6 ~~DC~~ ø22 CW Series Flush Silhouette Touchless Switches CW1H/CW4H ## ~~ee~~ Safety Precautions - Turn off the power to the product before starting installation, removal, wiring, maintenance, or inspection. Failure to turn power off may cause electrical shock or fire. ## Instructions ~~eee~~ - Since the power reset time is 100ms, start use after 100ms when power is turned on. ## Wiring - Turn off the power to the product before starting wiring. - If the load and this product are connected to separate power supplies, be sure to turn on the power to this product first. - Wiring errors may cause damage to the internal circuit. Be sure to refer to the connection diagram. - Do not install or use the product in the following places as it may cause malfunction or damage. - Use within the range of the rated operating voltage. - When using a switching power supply for power, be sure to ground the FG terminal. - 1) Near induction equipment or heat sources - 2) Locations subject to high vibration or shock - 3) Dusty places - Avoid parallel wiring using piping or ducts with high-voltage lines or power lines (especially inverter power lines), as malfunction or damage may be caused due to inductive noise. - 4) Locations subject to harmful gases - 5) Locations directly exposed to water, oil, chemicals, etc. - 6) Locations where icing may occur - When long wiring is used or when power sources or electromagnetic equipment may affect the product, use individual wiring. - Install the sensor so that light from sunlight or fluorescent lamps does not directly reach the detection surface. - The illumination unit may light dimly due to inductive noise, etc. In this case, take countermeasures by connecting each terminals LIGHT1, LIGHT2, and PNP illumination control type to 0V, and by connecting the below shunt resistor between +V for NPN illumination control type. (See diagram below) - Mirror surfaces with high reflectivity and reflectors may cause extremely long detection distances at unexpected detection ranges. - Water droplets, dirt, etc., on the sensor surface may affect the detection performance, so wipe off with a soft cloth before use. ## Shunt resistor R - Since PMMA is used as the material for the optical part, do not use organic solvents such as ammonia, sodium hydroxide, alcohol, or thinner. |Resistance value|Rated current| |---|---| |20kΩ|0.25W minimum| **==> picture [494 x 243] intentionally omitted <==** **----- Start of picture text -----**<br> Caution Connection diagram<br>• Do not use a power supply outside the rated operating voltage range (*1)<br>or AC power. Otherwise explosion or burning may occur. LIGHT1 5 Pin No.<br>• Avoid continuous lighting of two LED illumination colors R (*1) 6 4 2<br>simultaneously, as it may cause damage to the product. LIGHT2 6 (*2) 5 3 1<br>Installationn R<br>2<br>• Tighten the locking ring to the recommended tightening torque +V0V 1 R :Shunt resistor<br>(1.2 N-m) with the optional locking ring wrench (MW9Z-T1). Install L : Load<br>on a flat surface. Mounting on a non-flat surface may damage the OUT 3 L : Overcurrent protection<br>product or impair its waterproof performance ge COM 4 o element such as a fuse<br>(100mA max.)<br>Pin No. Terminal no.<br>Rubber washer Locking ring (*3) 1 +V<br>5 2 0V<br>LIGHT1<br>R (*3) 3 OUT<br>Panel thickness 0.8 to 10mm (*2) 4 COM<br>at Locking ring LIGHT2 6 5 LIGHT1<br>» Projection surface oe recommended tightening torque G 1 R 6 LIGHT2<br>1.2N∙m +V<br>2 *1) NPN cannot be connected<br>• When multiple units are installed adjacent to each other, take into 0V<br>*2) Connect only when dim<br>consideration the mounting centers of the switches and the location OUT 3 L lighting countermeasures<br>of objects to be detected. COM 4 are required<br>▲▲<br>▲▲<br>▲<br>▲<br>▲<br>▲<br>Main circuit<br>▲<br>▲<br>Main circuit<br>▲<br>▲<br>▲<br>▲<br>▲▲<br>▲▲<br>▲<br>▲<br>**----- End of picture text -----**<br> ## Caution - Do not use a power supply outside the rated operating voltage range or AC power. Otherwise explosion or burning may occur. - Avoid continuous lighting of two LED illumination colors simultaneously, as it may cause damage to the product. ## Installationn - Tighten the locking ring to the recommended tightening torque (1.2 N-m) with the optional locking ring wrench (MW9Z-T1). Install on a flat surface. Mounting on a non-flat surface may damage the product or impair its waterproof performance - When multiple units are installed adjacent to each other, take into consideration the mounting centers of the switches and the location of objects to be detected. **==> picture [123 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> Object<br>Object<br>ON ON OFF<br>**----- End of picture text -----**<br> *3) PNP connection not recommended Compatible connectors for external connection |Parts|Part No.|Manufacturer| |---|---|---| |Crimpsocket|DF51K-6DS-2C(800)|Hirose Electric Co. Ltd.| |Socket for<br>crimping terminal|DF51K-22SCF (800)<br>or DF51K-22SC(800)|| - Be sure to read the instructions carefully before performing installation, wiring, or maintenance work. For details on mounting, wiring, and maintenance, see the instruction manual from the URL below. URL: https://product.idec.com/?product=CW-H 7 ## Ordering Terms and Conditions ## Thank you for using IDEC Products. By purchasing products listed in our catalogs, datasheets, and the like (hereinafter referred to as “Catalogs”) you agree to be bound by these terms and conditions. Please read and agree to the terms and conditions before placing your order ## 1. Notes on contents of Catalogs - (1) Rated values, performance values, and specification values of IDEC products listed in this Catalog are values acquired under respective conditions in independent testing, and do not guarantee values gained in combined conditions. - Also, durability varies depending on the usage environment and usage conditions. - (2) Reference data and reference values listed in Catalogs are for reference purposes only, and do not guarantee that the product will always operate appropriately in that range. - (3) The specifications / appearance and accessories of IDEC products listed in Catalogs are subject to change or termination of sales without notice, for improvement or other reasons. - (4) The content of Catalogs is subject to change without notice. ## 2. Note on applications - (1) If using IDEC products in combination with other products, confirm the applicable laws / regulations and standards. Also, confirm that IDEC products are compatible with your systems, machines, devices, and the like by using under the actual conditions. IDEC shall bear no liability whatsoever regarding the compatibility with IDEC products. - (2) The usage examples and application examples listed in Catalogs are for reference purposes only. Therefore, when introducing a product, confirm the performance and safety of the instruments, devices, and the like before use. Furthermore, regarding these examples, IDEC does not grant license to use IDEC products to you, and IDEC offers no warranties regarding the ownership of intellectual property rights or non-infringement upon the intellectual property rights of third parties. - (3) When using IDEC products, be cautious when implementing the following. - i. Use of IDEC products with sufficient allowance for rating and performance - ii. Safety design, including redundant design and malfunction prevention design that prevents other danger and damage even in the event that an IDEC product fails - iii. Wiring and installation that ensures the IDEC product used in your system, machine, device, or the like can perform and function according to its specifications - (4) Continuing to use an IDEC product even after the performance has deteriorated can result in abnormal heat, smoke, fires, and the like due to insulation deterioration or the like. Perform periodic maintenance for IDEC products and the systems, machines, devices, and the like in which they are used. - (5) IDEC products are developed and manufactured as general-purpose products for general industrial products. They are not intended for use in the following applications, and in the event that you use an IDEC product for these applications, unless otherwise agreed upon between you and IDEC, IDEC shall provide no guarantees whatsoever regarding IDEC products. - i. Use in applications that require a high degree of safety, including nuclear power control equipment, transportation equipment (railroads / airplanes / ships / vehicles / vehicle instruments, etc.), equipment for use in outer space, elevating equipment, medical instruments, safety devices, or any other equipment, instruments, or the like that could endanger life or human health - ii. Use in applications that require a high degree of reliability, such as provision systems for gas / waterworks / electricity, etc., systems that operate continuously for 24 hours, and settlement systems ## 3. Inspections We ask that you implement inspections for IDEC products you purchase without delay, as well as thoroughly keep in mind management/maintenance regarding handling of the product before and during the inspection. ## 4. Warranty - (1) Warranty period - The warranty period for IDEC products shall be one (1) year after purchase or delivery to the specified location. However, this shall not apply in cases where there is a different specification in the Catalogs or there is another agreement in place between you and IDEC. - (2) Warranty scope - Should a failure occur in an IDEC product during the above warranty period for reasons attributable to IDEC, then IDEC shall replace or repair that product, free of charge, at the purchase location / delivery location of the product, or an IDEC service base. However, failures caused by the following reasons shall be deemed outside the scope of this warranty. - i. The product was handled or used deviating from the conditions / environment listed in the Catalogs - ii. The failure was caused by reasons other than an IDEC product - iii. Modification or repair was performed by a party other than IDEC - iv. The failure was caused by a software program of a party other than IDEC - v. The product was used outside of its original purpose - vi. Replacement of maintenance parts, installation of accessories, or the like was not performed properly in accordance with the user’s manual and Catalogs - vii. The failure could not have been predicted with the scientific and technical standards at the time when the product was shipped from IDEC - viii. The failure was due to other causes not attributable to IDEC (including cases of force majeure such as natural disasters and other disasters) Furthermore, the warranty described here refers to a warranty on the IDEC product as a unit, and damages induced by the failure of an IDEC product are excluded from this warranty. ## 5. Limitation of liability The warranty listed in this Agreement is the full and complete warranty for IDEC products, and IDEC shall bear no liability whatsoever regarding special damages, indirect damages, incidental damages, or passive damages that occurred due to an IDEC product. ## 6. Service scope The prices of IDEC products do not include the cost of services, such as dispatching technicians. Therefore, separate fees are required in the following cases. - (1) Instructions for installation / adjustment and accompaniment at test operation (including creating application software and testing operation, etc.) (2) Maintenance inspections, adjustments, and repairs (3) Technical instructions and technical training - (4) Product tests or inspections specified by you The above content assumes transactions and usage within your region. Please consult with an IDEC sales representative regarding transactions and usage outside of your region. Also, IDEC provides no guarantees whatsoever regarding IDEC products sold outside your region. - iii. Use in applications where the product may be handled or used deviating from the specifications or conditions / environment listed in the Catalogs, such as equipment used outdoors or applications in environments subject to chemical pollution or electromagnetic interference. If you would like to use IDEC products in the above applications, be sure to consult with an IDEC sales representative. **22 FACTORIES** **75 YEARS OF EXPERIENCE 3,900 EMPLOYEES WORLDWIDE 100 000 + REFERENCES** ## **EMEA SALES & CUSTOMER SUPPORT** **Contact our safety specialists at eu.support@idec.com** ## **BENELUX** Belgicastraat 7/1 1930 ZAVENTEM Belgium BEL: (+32) 27 25 05 00 NL: (+31) (70) 799 91 51 be.sales@apem.com ## **FRANCE** 55, avenue Edouard Herriot BP1 82303 CAUSSADE Cedex (+33) 5 63 93 14 98 fr.commercial@apem.com ## **GERMANY** Gewerbehof Giesing Paulsdorfferstr. 34, 2. OG D-81549 MUNICH MUNICH: (+49) 89 45 99 11 0 HAMBURG: (+49) 40 253054 0 de.info@apem.com ## **ITALY** Via Marconi 147G 12030 MARENE (CN) (+39) 0172 74 3170 apem.italia@apem.com ## **SWEDEN** Torshamnsgatan 39 S-16440 KISTA (+46) 8 626 38 00 se.info@apem.com ## **UNITED KINGDOM** Drakes Drive LONG CRENDON, Bucks HP18 9BA England (+44) 1 844 202400 uk.sales@apem.com ## **eu.idec.com** in| **Follow us on LinkedIn** | **[Follow us on Youtube]** an IDEC company
Updated at April 23, 2026
Founded in 1945, IDEC is a globally recognized leader in industrial automation, machine safety, and control products. Renowned for pioneering innovations in Human-Machine Interface (HMI) systems, the company is dedicated to creating a safe and efficient harmony between advanced workplace technology and human operators. At the core of IDEC’s extensive portfolio is a comprehensive selection of high-performance relays designed for demanding industrial environments. This includes a broad range of electromechanical power relays, solid-state relays, contactors, and critical safety relays, supported by a wide array of specialized relay accessories to ensure reliable and efficient switching. Beyond switching components, IDEC provides complete solutions for modern control panels and automated systems. Their robust engineering extends to advanced panel displays and instrumentation, precision light sensors, and dependable AC/DC power converters. With additional offerings in industrial switches, visual signaling units, and DIN rail terminal blocks, IDEC equips engineers with the high-quality components required to build secure, next-generation automation infrastructure.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →