CUT75-5FF
AC/DC Open Frame Power Supply (PSU), ITE, 3 Output, 75 W, 85V AC to 265V AC, Adjustable, Fixed
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:3 Output; Power Rating (Covection Cooling):75W; Power Rating (Forced Cooling):-; Input Voltage VAC:85V AC to 265V AC; Power Supply Output Type:Adjustable, Fixed; Output Voltage -
- SVHC: No SVHC (15-Jan-2018)
- Product Range: CUT75 Series
- No. of Outputs: 3 Output
- Output Power Max: 75W
- Input Voltage VAC: 85V AC to 265V AC
- Input Voltage AC Max: 265V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 8A
- Output Current - Output 2: 2.5A
- Output Current - Output 3: 1A
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: 15VDC
- Output Voltage - Output 3: -15VDC
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 75W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 74.95 € |
| Current stock | 10+ |
| Lead time | 30 days |
CUT75 Series https://product.tdk.com/en/power/cut www.emea.lambda.tdk.com/cut 75W Dual or Triple Output Low Profile Power Supplies The triple output CUT75 power supplies have two independent, isolated, converters, one for the main 5V output, and one for the auxiliary outputs. This topology provides several benefits - no minimum loading, enhanced load & line regulation and the ability to connect the auxiliary outputs in series to generate either a 24V or 30V output. The series is certified to both the IEC60601-1 and IEC62368-1 safety standards. Several mechanical configurations are available - open frame, an attached baseplate or with a baseplate and cover enclosure. Screw terminal blocks for the input and output connectors can also be selected. |**Features**|**Benefits**| |---|---| |• 3 x 5 Footprint With a Low 1.06” (27mm) Height|• Space Saving in End Equipment| |• Output 1 Isolated From Outputs 2 & 3|• Flexible Utilization| |• No Minimum Loading|• Reduced Load Regulation| |• Open Frame, Baseplate or Enclosed Formats|• Versatile Mounting| |• Three Year Warranty|• Low Cost of Ownership| |**Model Selector**<br>Model<br>Voltage<br>Adjustable<br>Max<br>Max<br>Load Reg<br>Line Reg<br>Ripple Noise<br>(V)<br>Range (V)<br>Current (A)<br>Power (W)<br>(mV)<br>(mV)(1)<br>(mV)(1)<br>V1<br>5<br>5 - 5.25<br>8.0<br>40.0<br>100<br>50<br>120<br>CUT75-522<br>V2<br>+12<br>Fixed<br>3.0<br>36.0<br>600<br>240<br>150<br>V3<br>-12<br>Fixed<br>1.0<br>600<br>240<br>150|**Model Selector**<br>Model<br>Voltage<br>Adjustable<br>Max<br>Max<br>Load Reg<br>Line Reg<br>Ripple Noise<br>(V)<br>Range (V)<br>Current (A)<br>Power (W)<br>(mV)<br>(mV)(1)<br>(mV)(1)<br>V1<br>5<br>5 - 5.25<br>8.0<br>40.0<br>100<br>50<br>120<br>CUT75-522<br>V2<br>+12<br>Fixed<br>3.0<br>36.0<br>600<br>240<br>150<br>V3<br>-12<br>Fixed<br>1.0<br>600<br>240<br>150|**Model Selector**<br>Model<br>Voltage<br>Adjustable<br>Max<br>Max<br>Load Reg<br>Line Reg<br>Ripple Noise<br>(V)<br>Range (V)<br>Current (A)<br>Power (W)<br>(mV)<br>(mV)(1)<br>(mV)(1)<br>V1<br>5<br>5 - 5.25<br>8.0<br>40.0<br>100<br>50<br>120<br>CUT75-522<br>V2<br>+12<br>Fixed<br>3.0<br>36.0<br>600<br>240<br>150<br>V3<br>-12<br>Fixed<br>1.0<br>600<br>240<br>150|**Model Selector**<br>Model<br>Voltage<br>Adjustable<br>Max<br>Max<br>Load Reg<br>Line Reg<br>Ripple Noise<br>(V)<br>Range (V)<br>Current (A)<br>Power (W)<br>(mV)<br>(mV)(1)<br>(mV)(1)<br>V1<br>5<br>5 - 5.25<br>8.0<br>40.0<br>100<br>50<br>120<br>CUT75-522<br>V2<br>+12<br>Fixed<br>3.0<br>36.0<br>600<br>240<br>150<br>V3<br>-12<br>Fixed<br>1.0<br>600<br>240<br>150|**Model Selector**<br>Model<br>Voltage<br>Adjustable<br>Max<br>Max<br>Load Reg<br>Line Reg<br>Ripple Noise<br>(V)<br>Range (V)<br>Current (A)<br>Power (W)<br>(mV)<br>(mV)(1)<br>(mV)(1)<br>V1<br>5<br>5 - 5.25<br>8.0<br>40.0<br>100<br>50<br>120<br>CUT75-522<br>V2<br>+12<br>Fixed<br>3.0<br>36.0<br>600<br>240<br>150<br>V3<br>-12<br>Fixed<br>1.0<br>600<br>240<br>150|**Model Selector**<br>Model<br>Voltage<br>Adjustable<br>Max<br>Max<br>Load Reg<br>Line Reg<br>Ripple Noise<br>(V)<br>Range (V)<br>Current (A)<br>Power (W)<br>(mV)<br>(mV)(1)<br>(mV)(1)<br>V1<br>5<br>5 - 5.25<br>8.0<br>40.0<br>100<br>50<br>120<br>CUT75-522<br>V2<br>+12<br>Fixed<br>3.0<br>36.0<br>600<br>240<br>150<br>V3<br>-12<br>Fixed<br>1.0<br>600<br>240<br>150|**Model Selector**<br>Model<br>Voltage<br>Adjustable<br>Max<br>Max<br>Load Reg<br>Line Reg<br>Ripple Noise<br>(V)<br>Range (V)<br>Current (A)<br>Power (W)<br>(mV)<br>(mV)(1)<br>(mV)(1)<br>V1<br>5<br>5 - 5.25<br>8.0<br>40.0<br>100<br>50<br>120<br>CUT75-522<br>V2<br>+12<br>Fixed<br>3.0<br>36.0<br>600<br>240<br>150<br>V3<br>-12<br>Fixed<br>1.0<br>600<br>240<br>150|**Model Selector**<br>Model<br>Voltage<br>Adjustable<br>Max<br>Max<br>Load Reg<br>Line Reg<br>Ripple Noise<br>(V)<br>Range (V)<br>Current (A)<br>Power (W)<br>(mV)<br>(mV)(1)<br>(mV)(1)<br>V1<br>5<br>5 - 5.25<br>8.0<br>40.0<br>100<br>50<br>120<br>CUT75-522<br>V2<br>+12<br>Fixed<br>3.0<br>36.0<br>600<br>240<br>150<br>V3<br>-12<br>Fixed<br>1.0<br>600<br>240<br>150|**Model Selector**<br>Model<br>Voltage<br>Adjustable<br>Max<br>Max<br>Load Reg<br>Line Reg<br>Ripple Noise<br>(V)<br>Range (V)<br>Current (A)<br>Power (W)<br>(mV)<br>(mV)(1)<br>(mV)(1)<br>V1<br>5<br>5 - 5.25<br>8.0<br>40.0<br>100<br>50<br>120<br>CUT75-522<br>V2<br>+12<br>Fixed<br>3.0<br>36.0<br>600<br>240<br>150<br>V3<br>-12<br>Fixed<br>1.0<br>600<br>240<br>150| |---|---|---|---|---|---|---|---|---| ||V2|+12|Fixed|3.0|36.0|600|240|150| ||V3|-12|Fixed|1.0||600|240|150| |CUT75-522|V1|5|5 - 5.25|8.0|40.0|100|50|120| ||V2|24|Fixed|1.0|24.0|750|300|150| ||(Leave common terminal unconnected)|||||||| |CUT75-5FF|V1|5|5 - 5.25|8.0|40.0|100|50|120| ||V2|+15|Fixed|2.5|37.5|750|300|150| ||V3|-15|Fixed|1.0||750|300|150| |CUT75-5FF|V1|5|5 - 5.25|8.0|40|100|50|120| ||V2|30|Fixed|1.0|30|750|300|150| ||(Leave common terminal unconnected)|||||||| Note, total power of V2 and V3 should not exceed specified maximum power. |**CUT75-**|**522**|**/**|**A**| |---|---|---|---| |blank<br>Open frame with JST connectors<br>/A<br>Cover with JST connectors<br>/B<br>Baseplate with JST connectors<br>/T<br>Open frame with screw connections<br>/TA<br>Cover with screw connections<br>/TB<br>Baseplate with screw connections<br>Output voltage see model selector|||| CUT75 Series 1 **==> picture [517 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---|---| |Model<br>CUT75-522<br>CUT75-5FF|||| |**Input**|||| |Input Voltage Range(1)|V|85 - 265Vac or 120 - 370Vdc*|| |Input Frequency|Hz|47 - 63|| |Input Current(100/200Vac)|A|2 / 1|| |Inrush Current at 200Vac (typ) (Cold Start)|A|36|| |Leakage Current (265Vac 50Hz)|mA|less than 0.3|| |Hold Up Time(typ) at 110/220Vac Input<br>|ms|20|| |Effciency (200Vac)|%|85|85| |Conducted & Radiated EMI|-|EN55011/EN55032-B, FCC Class B|| |Immunity<br>|-|IEC61000-4-2, -3, -4, -5, -6, -8, -11|| |Safety Certifcations and Markings|-|IEC/UL/CSA/EN62368-1, IEC/EN/ES/CSA60601-1, CE Mark and UKCA Mark|| ## **Immunity** |**Immunity**|**Immunity**|**Immunity**|**Immunity**|**Immunity**| |---|---|---|---|---| |Test|Standard|Test Level|Criteria|Notes| |ESD|EN61000-4-2|Air ±15kV and contact ±8kV|A|See IEC61000 immunity test report on website| |Radiated Susceptibility|EN61000-4-3|80M -1GHz: 10V/m<br>1.4 - 2.0GHz: 3V/m<br>2.0 - 2.7GHz: 1V/m|A|| |Electrical Fast Transient Burst|EN61000-4-4|±4kV|A|| |Surge|EN61000-4-5|Normal ±2kV<br>Common ±4kV|A|| |Conducted Susceptibility|EN61000-4-6|10Vrms|A|| |Magnetic Fields|EN61000-4-8|30A/m|A|| |Voltage Dips|EN61000-4-11|30% 500ms<br>60% 10ms<br>100% 20ms<br>100% 5000ms|B<br>B<br>B<br>B|| CUT75 Series 2 **==> picture [516 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---|---| |Model<br>CUT75-522<br>CUT75-5FF|||| |**Output**|||| |Output Voltage Adjustment|-|See model selector table|| |Switching Frequency|kHz|100|| |Load Regulation|-|See model selector table|| |Ripple & Noise<br>|-|See model selector table|| |Temperature Coeffcient|%/°C|V1: <0.02, V2 & 3 <0.03 (-20 to +70°C)|| |Minimum Load|-|No minimum load required|| |Overcurrent Protection|%|>105. Hiccup with auto recovery|| |Overvoltage Protection(2)|-|V1: 5.7-7.0, V2: 13.8 - 16.8|V1: 5.7-7.0, V2: 17.2 - 21.0| |Remote Sense|-|-|| |Remote On/Off|-|-|| |Parallel Operation|-|Not possible|| |Series Operation|-|Not possible|| |**Environmental**|||| |Operating Temperature(3)|°C|-20 to +70 (See derating drawing for open frame model)(3)|| |Operating Humidity|%RH|5 - 95 (Non Condensing)|| |Storage Temperature|°C|-30 to +85|| |Humidity (non condensing)|%RH|5 - 95|| |Cooling|-|Convection cooling|| |Altitude|m|3000|| |Withstand Voltage (For 1 minute)|Vac|Input to Ground: 2,000, Input to Output: 3,000, Output to Ground: 500, CH1 - V2/V3: 500|| |Vibration (Non operating)|-|10-55Hz (Sweep for 1min.)<br>19.6m/s2Constant X,Y,Z 1 hour each|| |Shock (Non operating, in package)|-|Less than 196.1m/s2, 11ms|| |**Other**|||| |Weight (Typ)|g|Open Frame: 210, Enclosed (/A): 400|| |Size (LxWxH)|mm|Open Frame: 127 x 76 x 27<br>Enclosed (/A): 130 x 82 x 38|| |Size (LxWxH)|Inches|Open Frame: 5.0 x 3 x 1.06<br>Enclosed (/A): 5.12 x 3.23 x 1.5<br>|| |Connectors|-|JST or screw terminal blocks (/T suffx)|| |MTBF - JEITA RCR-9102B(4)|Hours|169,333|| |Warranty|yrs|3|| ## Notes See website for detailed specifications, test methods and installation manual * Safety certified for AC input only (1) Derate linearly to 60% load from 100Vac to 85Vac input (2) Cycle AC to reset (3) See derating curves in installation manual for all mounting orientations and models (4) Part count method, Ground Fixed CUT75 Series 3 ## **CUT75 Open Frame Derating** ## **Outline Drawing CUT75 (Open Frame)** CUT75 Series 4 ## **Outline Drawing CUT75/T (Open Frame, Screw Terminals)** ## **Outline Drawing CUT75 /A (Enclosed)** CUT75 Series 5 **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr-powersolutions@tdk.com www.emea.lambda.tdk.com/fr **Italy Sales Office** Tel +39 02 61 29 38 63 tlf.it-powersolutions@tdk.com www.emea.lambda.tdk.com/it **Netherlands** tlf.nl-powersolutions@tdk.com www.emea.lambda.tdk.com/nl **TDK-Lambda Europe GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de **Austria Sales Office** Tel: +43 2256 655 84 tlg.at-powersolutions@tdk.com www.emea.lambda.tdk.com/at **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch-powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn ## **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com ## **TDK-Lambda Europe GmbH** Tel: Tel. +45 3222 8086 tlg.dk-powersolutions@tdk.com www.emea.lambda.tdk.com/dk **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit ~~ee~~ https://product.tdk.com/en/power/ CUT75-260862 April 7th, 2026 V2 CUT75 Series 6
Updated at April 27, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →