CUT355FF/B
POWER SUPPLY, MEDICAL, AC-DC, 35W
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Open Frame Power Supplies
- Product Range: CUT35 Series
- No. of Outputs: 3 Output
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Approvals: Medical
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 3A
- Output Current - Output 2: 1A
- Output Current - Output 3: 650mA
- Output Voltage - Output 1: 5V
- Output Voltage - Output 2: 15V
- Output Voltage - Output 3: -15V
- Power Rating (Convection Cooling): 19.5W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 36.14 € |
| Current stock | 10+ |
| Lead time | 30 days |
## ~~TDKLambda~~ CUT35 Series ## **Dual or Triple Output 35W Low Profi le Power Supplies** ## **Features** - 2 x 4 x 1.06” footprint - Output 1 isolated from outputs 2 & 3 - No minimum loading - - Three year warranty ## **Key Market Segments & Applications** ## |Specifi cations|Specifi cations|Specifi cations| |---|---|---| |Specifi cations||| |**Model**<br>**CUT35-522**<br>**CUT35-5FF**||| |AC Input Voltage (1)<br>Input Frequency<br>DC Input Voltage<br>Inrush Current (cold start)<br>Power Factor<br>Input Current (100 / 200VAC)<br>Temperature Coeffi cient (-20 to +70°C)<br>Overcurrent Protection<br>Overvoltage Protection (2)<br>Effi ciency (Typical at 200VAC Input)<br>Hold Up Time (115 / 230V input)<br>Leakage Current (265VAC 50Hz)<br>Operating Temperature (3)<br>Storage Temperature<br>Operating Humidity (non condensing)<br>Cooling<br>Withstand Voltage<br>Isolation Resistance<br>Vibration (non operating)<br>Shock<br>Immunity<br>Safety Agency Certifi cations<br>Conducted & Radiated EMI<br>Weight (Typ)<br>Size (WxLxH)<br>Warranty|VAC<br>Hz<br>VDC<br>A<br>-<br>A<br>-<br>-<br>V<br>%<br>ms<br>mA<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>-<br>g<br>in (mm)<br>yrs|85 - 265VAC<br>47 - 63Hz<br>88 - 370VDC (No safety certifi cation)<br>13A at 100VAC, 32A at 230VAC<br>Meets EN61000-3-2<br>1 / 0.5<br>V1: <0.02%/°C, V2 & 3 <0.03%/°C<br>> 105%<br>V1: 5.7-7.0, V2: 13.8 - 16.8V<br>V1: 5.7-7.0, V2: 17.2 - 21.0V<br>81%<br>82%<br>20ms<br><0.3mA<br>Open Frame & /B:-20 to +70°C. Derate linearly to 70% load from +55 to +70°C<br>Cover:-20 to +60°C. Derate linearly to 70% load from +45 to +60°C<br>-30 to +85°C<br>5 - 95% RH<br>Convection<br>Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC,<br>V1 to V2 / V3 500VAC for 1 min.<br>>100M at 25C & 70%RH, Output to Ground 500VDC<br>10 - 55Hz: 19.6m/s2constant sweep 1 min X, Y, Z for 1 hour<br>< 196.1 m/s2(20G)<br>IEC61000-4-2 (lv 3, 4), -3 (lv3), -4 (lv 4), -5 (lv3, 4), -6 (lv 3), -8 (lv 4), -11<br>UL60950-1, CSA60950-1-07 (cTUVus), EN60950-1, CE Mark<br>ANSI/AAMI ES60601-1, CSA 60601-1 (cTUVus), IEC/EN60601-1 (2 x MOOP)<br>EN55011-B, FCC-B<br>Open frame: 90, Baseplate: 136, Cover: 175<br>Open Frame: 2 x 4 x 1.06”” (50.8 x 101.6 x 27)<br>Baseplate: 2.22 x 4.8 x 1.1”” (56.5 x 122 x 28)<br>Cover: 2.48 x 4.92 x 1.42”” (63.1 x 125 x 36)<br>Three Years| (1) Derate linearly to 60% load from 100VAC to 85VAC input when ambient is <-10°C (2) Cycle AC to reset (3) See derating curves in installation manual for all mounting orientatons 1-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm 86 ## CUT35 Series ## Model Selector |Model Selector|Model Selector|Model Selector|Model Selector|Model Selector|Model Selector|Model Selector|Model Selector|Model Selector| |---|---|---|---|---|---|---|---|---| |<br>Model Selector||||||||| |**Model**<br>**Adjust**<br>**Max**<br>**Max**<br>**Load Reg Line Reg**<br>**Ripple Noise**<br>**Voltage (V)**<br>**Range (V)**<br>**Current (A)**<br>**Power (W)**<br>**(mV)**<br>**(mV)**<br>**(mV)**||||||||| |CUT35-522|V 1<br>V2<br>V3|5V<br>+12V<br>-12V|5 - 5.25<br>Fixed<br>Fixed|3<br>1.2<br>0.85|15<br>20.4<br>20.4|100<br>600<br>600|50<br>240<br>240|120<br>150<br>150| |CUT35-522|V1<br>V2|5V<br>24V|5 - 5.25<br>Fixed|3<br>0.85|15<br>20.4|100<br>750|50<br>300|120<br>150| ||(Leave common terminal unconnected)|||||||| |CUT35-5FF|V1<br>V2<br>V3|5V<br>+15V<br>-15V|5 - 5.25<br>Fixed<br>Fixed|3<br>1<br>0.65|15<br>19.5<br>19.5|100<br>750<br>750|50<br>300<br>300|120<br>150<br>150| |CUT35-5FF|V1<br>V2|5V<br>30V|5 - 5.25<br>Fixed|3<br>0.65|15<br>19.5|100<br>750|50<br>300|120<br>150| ||(Leave common terminal unconnected)|||||||| Note CUT35 can be confi gured as a dual or single output. ## Outline Drawing |Options|Options| |---|---| |**Suffi x**|**Description**| |Blank|Open frame with JST connectors| |/A<br>/B|Cover with JST connectors<br>Baseplate with JST connectors| For Additional Information, please visit us.tdk-lambda.com/lp/products/cut75-series.htm 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 87 Revision P1.2: Mar 2017
Updated at February 9, 2023
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →