CUS600M1-28
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 1 Output, 602W, 400.4 W, 85V AC to 265V AC
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: CUS600M1 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 14.3A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 28V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
- Power Rating (Forced Cooling): 602W
- Power Rating (Convection Cooling): 400.4W
| Delivery and price | |
|---|---|
| Units per pack | 12 |
| Price | 143.37 € |
| Current stock | 10+ |
| Lead time | 30 days |
## CUS600M and CUS600M1 Series ## 3 x 5” 600W AC-DC Power Supplies https://product.tdk.com/en/power/cus-m www.emea.lambda.tdk.com/cus600m The compact CUS600M is packaged in the industry standard 3x5” footprint and can deliver 600W with forced air or 400W with a 600W peak power with convection cooling. With Medical & ITE certifications, the unit can used in both Class I & Class II (no ground wire) applications[(1)] . A 5V 2A standby voltage, remote on/off, remote sense and a Power Good signal is standard on the CUS600M. Options include an internal fan and output adjustment. The CUS600M1 models offer a reduced feature set for cost optimization. |**Features**|**Benefits**| |---|---| |• 400W (600W Peak) Convection Cooled|• Quiet Operation| |• 600W with Forced Air|• Can Utilize System Airflow or Integrated Fan| |• Medical Certifications (2 x MOPP)|• Suitable for B and BF Type Medical Equipment| |• Class B Conducted and Radiated EMI|• Easier System EMC Compliance| |• Suitable for Class I and Class II installations(1)|• Flexible Utilization| |• Compact 3 x 5 x 1.46” Size|• Space Saving in End Equipment| |• Enclosure & Other Options|• Versatile Application| ## **Model Selector** |||Nominal|Output Adjustment (V)|Output Adjustment (V)|Output Adjustment (V)|Maximum|Maximum||Maximum|Maximum||Peak|Peak|Maximum|Maximum|Maximum| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Model||Output<br>Voltage (V)|(Specify /ADJ option<br>Voltage (V)<br>suffix*)(2)|||Current<br>Convection (A)|Current<br>Convection (A)||Current<br>Forced Air (A)|||Current<br>(A)||Power<br>Convection (W)||Power<br>Forced Air (W)| |CUS600M-12||12|11.7 - 12.9|||33.4|||50.0|||50.0||400.8||600.0| |CUS600M-19||19|18.5 - 20.5|||21.1|||31.6|||31.6||400.9||600.4| |CUS600M-24||24|23.4 - 25.9|||16.7|||25.0|||25.0||400.8||600.0| |CUS600M-28||28|27.3 - 30.2|||14.3|||21.5|||21.5||400.4||602.0| |CUS600M-32||32|31.2 - 34.5|||12.5|||18.8|||18.8||400.0||601.6| |CUS600M-36||36|35.1 - 38.8|||11.1|||16.7|||16.7||399.6||601.2| |CUS600M-48||48|46.8 - 51.8|||8.4|||12.6|||12.6||403.2||604.8| |||||||||||||||||| |**CUS600M-**|**CUS600M-**||||||**12**||||**/**|||**EF**||| |||||||||||||||||| |Features||CUS600M-|CUS600M1-|||||||||||||| |Standby Voltage<br>Remote On/Off<br>Remote Sense||Yes|Not<br>Available||Output voltage 12, 19, 24, 28, 32, 36, 48||Output voltage 12, 19, 24, 28, 32, 36, 48||Output voltage 12, 19, 24, 28, 32, 36, 48||||blank<br>/EF<br>/ADJ|Open frame construction<br>Enclosed with end fan (exhaust air)*<br>Output adjustment potentiometer**||| |Power Good Signal|||||||||||||/SF|Single input fuse in line**||| - /EF model has /ADJ included (CUS600M only) - ** Not available for CUS600M1 models Other options are available, please contact sales CUS600M Series 1 **==> picture [516 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---| |Model<br>CUS600M||| |**Input**||| |Input Voltage Range (Operating)|Vac|85 - 265 (See derating curves)<br>| |Nominal Input Voltage Range|Vac|100 - 240 (Note: Safety certifed for 90-264Vac only)| |Input Frequency|Hz|47 - 63| |Input Current (110/230Vac)|A|< 6.0 / 3.0 (600W)| |Inrush Current at 230Vac (typ) (Cold Start)|A|<50| |Leakage Current|uA|<200uA at 265Vac 60Hz| |Touch Current (Enclosure Leakage)|uA|<100| |Power Factor (115/230Vac)|-|0.99 / 0.95| |Harmonic Compliance|-|Meets IEC61000-3-2 Class A| |No Load Power Consumption|W|<0.5W at 230Vac (Remote off and no load on 5Vsb)| |Hold Up Time (typ) at 115Vac Input<br>|ms|>22ms 400W load, >14ms 600W load| |Effciency|-|Up to 96%| |Conducted & Radiated EMI (Class I only(1))|<br>-|EN55032/EN55011-B (See installation / instruction manual for conditions)| |Immunity (Class I only(1))|-|Compliant with EN60601-1-2;2015 (Ed4), see immunity table| |Insulation Class<br>|-|Construction suitable for Class I or Class II installation(1)| |Safety Certifcations and Markings|-|IEC/EN/UL/CSA62368-1 and IEC/EN/ES/CSA60601-1. CE Mark and UKCA Mark| |**Immunity**|**Immunity**|**Immunity**|**Immunity**|**Immunity**| |---|---|---|---|---| |||||| |Test|Standard|Test Level|Criteria|Notes(1)(the power stated below is total power (main power + fan output))| |ESD|EN61000-4-2|4|A|-<br>| |Radiated Susceptibility|EN61000-4-3|3|A|Includes proximity feld requirements of EN60601-1-2:2015| |Electrical Fast Transient Burst|EN61000-4-4|4|A|(AC Port, 5kHz and 100kHz)| |Surge|EN61000-4-5|3|A|-| |Conducted Susceptibility<br>|EN61000-4-6|3|A|-| |Magnetic felds|EN61000-4-8|4|A|-| |Voltage Dips and<br>Input Interuptions|EN61000-4-11<br>Class 3 Industrial,<br>incl EN55024<br>(100Vac)|0% for 1/2 cycle<br>0% for 1 cycle<br>40% for 10/12 cycles<br>70% for 25/30 cycles<br>80% for 250/300 cycles<br>0% for 250/300 cycles|A<br>A/B<br>A/B<br>A/B<br> <br>A/B<br>B|-<br>A up to 330W, B above 330W<br>A up to 210W, B above 210W<br>A up to 500W, B above 500W<br>A up to 570W, B above 570W<br>-| ||EN61000-4-11<br>Class 3 Industrial,<br>incl EN55024<br>(240Vac)|<br>0% for 1/2 cycle<br>0% for 1 cycle<br>40% for 10/12 cycles<br>70% for 25/30 cycles<br>80% for 250/300 cycles<br>0% for 250/300 cycles|A<br>A/B<br>A/B<br>A<br> <br>A<br>B|-<br>A up to 330W, B above 330W<br>A up to 570W, B above 570W<br>-<br>-<br>-| ||EN60601-1-2:2015<br>(100Vac)|<br>0% for 1/2 cycle<br>0% for 1 cycle<br>70% for 25/30 cycles<br>0% for 250/300 cycles|A<br>A/B<br>A/B<br>B|Customer to consider essential performance of end equipment<br>A up to 330W, B above 330W<br>A up to 500W, B above 500W<br>-| ||EN60601-1-2:2015<br>(240Vac)|<br>0% for 1/2 cycle<br>0% for 1 cycle<br>70% for 25/30 cycles<br>0% for 250/300 cycles|A<br>A/B<br>A<br>B|Customer to consider essential performance of end equipment<br>A up to 330W, B above 330W<br>-<br>-| |SEMI F47 Line Dip|SEMI F47|-|-|At input voltages > 200Vac| CUS600M Series 2 **==> picture [516 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---| |Model<br>CUS600M||| |**Output**||| |Line Regulation|%|0.5% (85 - 265Vac)| |Load Regulation|%|1% (0 - 100% load)| |External Load Capacitance|uF|12-19V: 10,000, 24V: 8,000, 28V: 5,000, 32-36V: 4,000, 48V: 3,000| |Ripple & Noise<br>|mV|12V: 240mV, 19V - 28V: 360mV, 32V - 48V: 480mV| |Temperature Coeffcient|%/°C|±0.02%/°C| |Minimum Load|-|No minimum load required| |Overcurrent Protection|%|>105%. Hiccup mode, automatic recovery| |Overvoltage Protection|V|12V: 13.8-16.2, 19V: 21.8-25.7, 24V: 27.6-32.4, 28V:32.2-37.8, 32V: 36.8-43.2, 36V: 41.4-48.6, 48V: 55.2-64.8<br>Latching (unit shutdown), cycle AC input to reset| |Overtemperature Protection|-|Latching (unit shutdown), cycle AC input to reset| |Remote Sense|-|0.5V total compensation(2)| |Remote On/Off|-|Opto-isolated. Inhibit: Low = ON, High = OFF(2)| |Power Good|-|Combined AC Fail and DC OK opto isolated signal(2)| |Standby Voltage|-|Open frame version: 5V 2A, /EF version 5V 1.5A(2)| |Parallel Operation|-|Not possible| |**Environmental**||| |Operating Temperature|°C|-20°C to +70°C, see derating curves below| |Storage Temperature|°C|-40°C to +85°C| |Operating Humidity (non condensing)|%RH|10 - 95%RH| |Cooling|-|Convection cooling or forced air (2.7m/s). (/EF version, air exits from fan end)| |Altitude|m|5,000m. Operating, transportation and storage| |Withstand Voltage (For 1 minute)|Vac|Input to Ground 2kVAC (1xMOPP), Input to Output 4kVAC (2xMOPP),<br>Output to Ground 1.5kVAC (1xMOPP)| |Isolation Resistance|MΩ|>100MΩ at 25°C, 70%RH Output - FG 500VDC| |Vibration (Non Operating)|-|10-55Hz (1 min sweep). Maximum 19.6m/s2; x, y, z for 1 hour each| |Shock|-|<196m/s2| |**Other**||| |Weight (Typ)|g|Open frame: 470, /EF: 790| |Size (LxWxH)|mm|Open frame: 127 x 76.2 x37, /EF: 157 x 85 x 42.5| |Size (LxWxH)|Inches|Open frame: 5 x 3 x 1.46, /EF: 6.18 x 3.35 x 1.67| |Connectors|-|Input: JST VHR-5N, Output: M4 screws, Standby: JST XHP-2, Signals: JST PHDR-08VS| |Warranty|yrs|5| Notes: See website for detailed specifications, test methods and installation manual Specification parameters apply at 25°C ambient temperature unless otherwise stated. (1) Class II operation may require additional EMC filtering, contact factory for assistance. (2) Not available on the CUS600M1 models, see model selector CUS600M Series 3 ## **Mounting Orientation** ## **Airflow Direction** CUS600M Series 4 ## **Convection Cooling CUS600M-12** **(Zero load on Standby Voltage. Wide range input. Additional derating applies below 115Vac input)** ## **Convection Cooling CUS600M-19 to -48** **(Zero load on the Standby Voltage output. Wide range input. Additional derating applies below 115Vac input)** CUS600M Series 5 ## **Convection Cooling (All models)** **(Loading applied on the Standby Voltage output. Wide range input. Additional derating applies below 115Vac input)** ## **Convection Cooling CUS600M-12** **(Loading applied on the Standby Voltage output. 176 - 265Vac input. Additional derating applies below 115Vac input)** CUS600M Series 6 ## **Convection Cooling CUS600M-19 to -48V** **(Loading applied on the Standby Voltage output. 176 - 265Vac input. Additional derating applies below 115Vac input)** ## **Forced Air Cooling CUS600M-12 (2.7m/s)** **(Loading applied on the Standby Voltage output. Wide range input. Additional derating applies below 115Vac input)** CUS600M Series 7 ## **Forced Air Cooling CUS600M-19 to -48 (2.7m/s)** **(Loading applied on the Standby Voltage output. Wide range input. Additional derating applies below 115Vac input)** ## **CUS600M-xx/EF (End Fan)** CUS600M Series 8 ## **Derating versus Input Voltage** ## **(All models, all conditions)** CUS600M Series 9 ## **Mechanical Specification** **==> picture [220 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Outline Drawing CUS600M Open Frame Unit<br>**----- End of picture text -----**<br> ## **Mechanical Specification** **==> picture [226 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Outline Drawing CUS600M1 Open Frame Unit<br>**----- End of picture text -----**<br> CUS600M Series 10 **==> picture [516 x 35] intentionally omitted <==** ## **Outline Drawing CUS600M/EF (End Fan)** **==> picture [510 x 300] intentionally omitted <==** CUS600M Series 11 ## **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr-powersolutions@tdk.com www.emea.lambda.tdk.com/fr **Italy Sales Office** Tel: +39 02 61 29 38 63 tlf.it-powersolutions@tdk.com www.emea.lambda.tdk.com/it ## **Netherlands** ## **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com ## **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en tlf.nl-powersolutions@tdk.com www.emea.lambda.tdk.com/nl ## **TDK-Lambda Germany GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de ## **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com ## **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn ## **Austria Sales Office** Tel: +43 2256 655 84 tlg.at-powersolutions@tdk.com www.emea.lambda.tdk.com/at ## **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch-powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **Nordic Sales Office** ## **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com ## **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com Tel: +45 8853 8086 tlg.dk-powersolutions@tdk.com www.emea.lambda.tdk.com/dk ## **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk ## **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit ~~oe~~ https://product.tdk.com/en/power/ CUS600M_Datasheet_260593 June 18th, 2024 V10 CUS600M Series 12
Updated at April 27, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →