CUS30M12/A
POWER SUPPLY, AC-DC, 12V, 2.5A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Product Range: CUS30M Series
- No. of Outputs: 1Outputs
- Output Power Max: 30W
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Approvals: ITE, Household & Medical
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.5A
- Output Voltage - Output 1: 12V
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 25.33 € |
| Current stock | 10+ |
| Lead time | 30 days |
CUS30M & CUS60M Series ## Single Output 30 to 60W Medical & ITE Power Supplies www.us.tdk-lambda.com/lp/products/cus-m-series www.emea.tdk-lambda.com/cus30_60 The CUS30M and CUS60M are 2” x 3” footprint AC/DC power supplies with outputs ranging from 5V to 48V. They are certifi ed to IEC60601-1 3rd edition (medical), IEC60950-1 and IEC60335-1 with compliance to EN60601-1-2:2015 Edition 4 immunity requirements. Rated at 30W and 60W, these compact products meet class B conducted and radiated EMI in either a Class I or Class II (double insulated) construction, without the need for external fi ltering. |**Features**|**Benefi ts**| |---|---| |• 30 to 60W Convection Cooled|• Quite Operation| |• Medical Certifi cation (2 x MoPP)|• Suitable for B and BF Rated Equipment| |• Class B Conducted and Radiated EMI|• Easier System Compliance| |• Suitable for Class I and II Installations|• Flexible Utilisation| |• Compact 2” x 3” Footprint|• Space Saving in End Equipment| |• Enclosure, Mounting and Connection Options|• Versatile Application| ## **Model Selector** |Model|Output<br>Voltage (V)|Maximum<br>Current (A)|Maximum<br>Power (A)|Load<br>Reg (mV)|Line<br>Reg (mV)|Ripple Noise<br>(mV)(1)|Effi ciency<br>(typ) %(2)|Average Active<br>Effi ciency (typ) %(2)| |---|---|---|---|---|---|---|---|---| |CUS60M-5|5|6|30|100|20|120|81 / 81|81 / 79.5| |CUS30M-12|12|2.5|30|120|48|120|87 / 88|87 / 87| |CUS60M-12|12|5|60|120|48|120|87 / 88|87 / 86| |CUS30M-15|15|2|30|120|60|150|87 / 88|87 / 87| |CUS60M-15|15|4|60|120|60|150|87.5 / 87|87 / 86.5| |CUS30M-18|18|1.7|30.6|144|72|150|87 / 88|87 / 87| |CUS60M-18|18|3.25|60.3|144|72|150|88 / 88|87 / 87| |CUS30M-24|24|1.25|30|192|96|150|88 / 90|87 / 87| |CUS60M-24|24|2.5|60|192|96|150|89 / 90|88 / 87| |CUS30M-36|36|0.84|30.24|288|144|200|88 / 90|88 / 89| |CUS30M-48|48|0.63|30.24|384|192|200|88 / 90|88 / 89| |CUS60M-48|48|1.25|60|384|192|200|89 / 91|90 / 89| ## **Options** |**Options**<br>Suffi x|| |---|---| |Suffi x|Description| |Blank|Open frame, JST connectors| |/A|Cover, JST connectors. See website for derating| |/CO2|Open frame, JST connectors, pcb coating| |/M|Open frame, Molex 5195-03 & -04 mating connectors| |/P|Open frame, JST connectors, Pcb mount| |/S|Open frame, JST connectors, single fuse, (Line only)| CUS30M & CUS60M Series 1 **==> picture [511 x 34] intentionally omitted <==** ## **Specifi cations** **==> picture [511 x 220] intentionally omitted <==** **----- Start of picture text -----**<br> Model CUS30M CUS60M<br>Input<br> Input Voltage range V 85 - 264VAC (3)<br> Input Frequency Hz 47- 63Hz<br> Input Current (110/230VAC) A 0.6 / 0.4 5V: 0.7 / 0.5, 12-48V: 1.2 / 0.8<br> Inrush Current at 230VAC (typ) (Cold Start) A 30A at 115VAC, 60A at 230VAC<br> Leakage Current uA <0.25mA at 265VAC, 60Hz <0.2mA at 265VAC, 60Hz<br> Touch Current uA 100µA at 265VAC, 60Hz 60µA at 265VAC, 60Hz<br> Harmonic Compliance - Meets EN61000-3-2<br> No Load Power Consumption W <0.3W at 265VAC <0.5W at 265VAC<br> Hold Up Time (typ) at 115VAC Input ms 20 / 100<br> Effi ciency - See model selector<br> Average Effi ciency - See model selector. Measured at 25%, 50%, 75% and 100% load conditions<br> Conducted & Radiated EMI - EN55011-B, EN55032-B, FCC Class B<br> Immunity - IEC61000-4-2, IEC60601-1-2 Ed4. See immunity table<br> Insulation Class - Construction suitable for Class I or Class II installation<br> Safety Agency Certifi cations - EN/IEC/UL/ES/CSA60601-1, EN/IEC/UL/CSA60950-1, IEC60335-1, CE Mark<br>**----- End of picture text -----**<br> ## **Immunity** |**Immunity**|**Immunity**|**Immunity**|**Immunity**|**Immunity**| |---|---|---|---|---| |Test|Standard|Test Level|Criteria|Notes| |ESD|EN61000-4-2|3 & 4|A|Level 4 contact discharge only| |Radiated Susceptibility|EN61000-4-3|3|A|-| |Electrical Fast Transient Burst|EN61000-4-4|3|A|-| |Surge|EN61000-4-5|3 & 4|A|Level 4 common mode only| |Conducted Susceptibility|EN61000-4-6|3|A|-| |Magnetic f elds|EN61000-4-8|4|A|-| |Voltage Dips|EN61000-4-11|Class 3|B<br>A|100 - 120VAC<br>200 - 240VAC| |Short Interruptions|EN61000-4-11|Class 3|B|-| |Voltage Dips|EN60601-1-2:2015|Class 2|B<br>A|100 - 120VAC<br>200 - 240VAC| |Short Interruptions|EN60601-1-2:2015|Class 2|B|-| |SEMI F47 Line Dip|SEMI F47|-|-|At input voltages > 200VAC| CUS30M & CUS60M Series 2 **==> picture [511 x 34] intentionally omitted <==** **==> picture [512 x 415] intentionally omitted <==** **----- Start of picture text -----**<br> Specifi cations<br>Model CUS30M CUS60M<br>Output<br> Line Regulation mV See model selector<br> Load Regulation mV See model selector<br> Ripple & Noise mV See model selector<br> Temperature Coeffi cient %/°C <0.02%/°C<br> Minimum Load - No minimum load required<br> Overcurrent Protection - >105% of rated current. Class 2 Limited Power Source (4)<br> Overvoltage Protection (5) V > 115% of nominal output >120% of nominal output<br> Remote Sense No<br> Indicators - None<br> Parallel Operation - Not possible<br> Series Operation - Possible, see installation manual<br> Environmental<br> Operating Temperature (-30°C start-up) -20 to +70°C. Derate linearly to 50% load from +50 to +70°C (6)<br> Storage Temperature °C -40° to +85°C<br> Humidity (non condensing) %RH 10 - 95%RH (Operating & Storage)<br> Cooling - Convection<br> Altitude m 5,000m, derate operating ambient by 5°C/1000m above 3,000m<br> Withstand Voltage (For 1 minute) VAC Input to Ground 2kVAC (1xMOPP), Input to Output 4kVAC (2xMOPPs), Output<br>to Ground 1.5kVAC (1xMOPP) suitable for B & BF rated equipment<br> Isolation Resistance MΩ >100MΩ at 25°C, 70%RH & 500VDC<br> Vibration (Non Operating) - 10 - 55Hz: 19.6m/s [2] constant sweep 1 min X, Y, Z for 1 hour<br> Shock - < 196.1 m/s [2] , MIL-STD-810F<br> Other<br> Size (WxLxH) mm 50.8 x 76.2 x 24.2 50.8 x 76.2 x 26.7<br> Size (WxLxH) Inches 2 x 3 x 0.95 2 x 3 x 1.05<br> Connectors (JST) Input (CN1): B2P3-VH(LF)(SN) (Mates with VHR-3N housing).<br> Option code /M for Molex - Output (CN-51): B4P-VH(LF)(SN) (Mates with VHR-4N)<br> MTBF - Telcordia SR-332 issue 3 (7) Hours 8,008,742 6,324,138<br> Warranty yrs 3 years<br>**----- End of picture text -----**<br> ## Notes See website for detailed specifi cations, test methods and installation manual See installation manual for terminal pin and hand tool information (1) Ripple level increases at light loading to meet new effi ciency standards (2) 115/230VAC. Average effi ciency measured at 25, 50, 75 and 100% load (3) CUS30M: Derate linearly to 80% load from 115VAC to 85VAC. CUS60M-12, 18 & 48: Derate linearly to 80% load from 100VAC to 85VAC. CUS60M-15 derate linearly to 60% load from 100Vac (4) All models except CUS60M-5 (5) Cycle AC input to reset (6) CUS30M-48 and CUS60M-12: Derate linearly to 50% load from +45 to +70oC. CUS60M-15: 50% load from +40 to +70oC. Models with /A cover have additional derating, see website. (7) 24V output model, 25°C ambient, full load, 230VAC input CUS30M & CUS60M Series 3 ## **Mechanical Specifi cation** ## **Outline Drawing CUS30M Series (Open Frame)** ## **Mechanical Specifi cation** ## **Outline Drawing CUS60M Series (Open Frame)** CUS30M & CUS60M Series 4 **==> picture [232 x 39] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specifi cation<br>Outline Drawing CUS30M Series (Enclosed /A)<br>**----- End of picture text -----**<br> CUS30M & CUS60M Series 5 **==> picture [232 x 39] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specifi cation<br>Outline Drawing CUS60M Series (Enclosed /A)<br>**----- End of picture text -----**<br> CUS30M & CUS60M Seriess 6 ## **Mechanical Specifi cation** ## **Outline Drawing CUS30M Series (PCB Mount /P)** ## **Mechanical Specifi cation** ## **Outline Drawing CUS60M Series (PCB Mount /P)** ## **Mechanical Specifi cation** ## **Outline Drawing CUS30M Series (Molex /M)** CUS30M & CUS60M Series 7 ## **Mechanical Specifi cation** ## **Outline Drawing CUS60M Series (Molex /M)** CUS30M & CUS60M Series 8 www.us.tdk-lambda.com/lp/products/cus-m-series www.emea.tdk-lambda.com/cus30_60 CUS30-60M Jul 29, 2019 v1.2 CUS30M & CUS60M Series 10
Updated at February 9, 2023
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →