CUS1500M-24
POWER SUPPLY, AC-DC, 24V, 63A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Power Supply Applications:Medical; No. of Outputs:1Outputs; Output Power Max:1.512kW; Output Voltage - Output 1:24V; Output Current - Output 1:63A; Output Voltage - Outp 73AC4641
- No. of Outputs: 1Outputs
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 614.73 € |
| Current stock | 10+ |
| Lead time | 30 days |
CUS1500M Series ## 1500W Medical and Industrial Power Supplies https://product.tdk.com/en/power/cus-m www.emea.lambda.tdk.com/cus1500m The CUS1500M are 1500W rated AC-DC power supplies with output voltages from 12V to 48V. They are certified to IEC60601-1 3rd edition (medical) and IEC62368-1 with compliance to the EN60601-1-2:2015 Edition 4 immunity requirements. The series is also certified to EN62477-1 (OVC III). These 7-year warranty[(1)] products feature low acoustic noise (<45dBA) and meet both class B radiated and conduction EMI standards. Features include an isolated 5V 1A standby voltage, remote on/off and an output-low/fan-fail isolated signal. Up to five units can be connected in parallel for additional power. |**Features**|**Benefits**| |---|---| |• Low Audible Noise Fan (<45dBA)|• Quiet Operation| |• Medical Certification (2 x MoPP)|• Suitable for B and BF Rated Equipment| |• Class B Conducted and Radiated EMI|• Easier System Compliance| |• Compact 127 x 63 x 261mm (5 x 2.48 x 10.28”) Package|• Space Saving in End Equipment| |• Seven Year Warranty(1)|• Low Cost of Ownership| |**Model Selector**|**Model Selector**|||||||| |---|---|---|---|---|---|---|---|---| ||Output|Adjustment|Maximum|Maximum|Load|Line|Ripple|Efficiency| |Model|Voltage|Range|Current|Power|Reg|Reg|& Noise|(%)| ||(V)|(V)|(A)|(W)|(mV)|(mV)|(mV)|(115/230Vac)| |CUS1500M-12|12|10.2 -14.4|125|1500|96|48|150|82 / 85| |CUS1500M-15|15|12.8 - 18|100|1500|120|60|150|82 / 85| |CUS1500M-24|24|20.4 - 28.8|63|1512|144|96|180|85 / 88| |CUS1500M-36|36|30.6 - 43.2|42|1512|216|144|250|85 / 88| |CUS1500M-48|48|40.8 - 52.8|32|1536|288|192|300|85 / 88| |**CUS1500M-**|**12**|**/**|**RF**| |---|---|---|---| |Output voltage 12, 15, 24, 36, 48<br>blank<br>Dual fuses, air enters over input/output terminals<br>/CO2<br>Pcb coating<br>/SF<br>Single input fuse (Line)<br>/RF<br>Reverse fan, air exits over input/output terminals|||| Option combinations are available, please contact your local sales office CUS1500M Series 1 **==> picture [517 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---| |Model<br>CUS1500M||| |**Input**||| |Input Voltage Range|Vac|85 - 265(2)<br>| |Nominal Input Voltage Range|Vac|100 - 240 (Note: Safety certifed for 90-264Vac)<br>| |Input Frequency|Hz|47 - 63 (Note: Safety certifed for 50-60Hz)<br>| |DC Input Voltage Range|Vdc|120 - 340 (Note: Safety certifed for AC input only)| |Input Current (110/230VAC)|A|16 / 8| |Inrush Current at 100/200VAC (Cold Start)|A|60| |Leakage Current|uA|<300| |Power Factor (10/200VAC)|-|0.98 / 0.95| |Harmonic Compliance|-|Meets IEC61000-3-2| |Hold Up Time<br>|ms|20 typical| |Effciency|-|See model selector| |Conducted & Radiated EMI|-|EN55011 / EN55032-B, FCC Class B, VCCI-B| |Immunity|-|See immunity section| |Insulation Class<br>|-|Class I| |Safety Certifcations and Markings|-|IEC/ES/CSA/EN60601-1, IEC/UL/CSA/EN62368-1, 60950-1, EN62477-1 (OVC III), CE Mark and UKCA Mark| |**Immunity**||||| |---|---|---|---|---| |||||| |Test|Standard|Test Level|Criteria|Notes| |ESD|EN61000-4-2|3|B|-| |Radiated Susceptibility|EN61000-4-3|3|A|-| |Electrical Fast Transient Burst|EN61000-4-4|3|B|-| |Surge|EN61000-4-5|3 (4)|B|Level 4 common mode only| |Conducted Susceptibility<br>|EN61000-4-6|3|A|-| |Magnetic felds|EN61000-4-8|4|A|-| |ESD|IEC60601-1-2 Ed.4|4|A|-| |Radiated Susceptibility||3|A|-| |Electrical Fast Transient Burst||3|A|-| |Voltage Dips and<br>Input Interruptions|EN61000-4-11|0% for 1 cycle|A|| |||40% for 10/12 cycles|B|| |||70% for 25/30 cycles|B|-| |||0% for 250/300 cycles|B|-| ||IEC60601-1-2 Ed.4|0% for 1/2 cycle|A|-| |||0% for 1 cycle|A|-| |||70% for 25/30 cycles|B|Customer to consider essential performance of end equipment| |||0% for 250/300 cycles|B|-| |SEMI F47 Line Dip|SEMI F47|-|-|At input voltages > 200Vac| CUS1500M Series 2 **==> picture [516 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---| |Model<br>CUS1500M||| |**Output**||| |Switching Frequency (Converter)|kHz|83| |Line Regulation|mV|See model selector| |Load Regulation|mV|See model selector| |External Load Capacitance|uF|100,000 maximum| |Ripple & Noise<br>|mV|See model selector| |Temperature Coeffcient|%/°C|<0.02| |Minimum Load|-|No minimum load required| |Overcurrent Protection|%|>105, constant current style. After 5 seconds the unit will shutdown| |Overvoltage Protection|%|125 - 150 (115 - 125 for 48V model), cycle AC line to reset| |Overtemperature Protection|-|Yes, cycle the AC to reset| |Remote Sense|-|Yes| |Remote On/Off|-|Apply external or Standby voltage to enable output voltage| |DC Good / Fan Alarm|-|Isolated open collector signal, high on fail| |Standby Voltage|-|5V 1A isolated (always on)| |Indicators|-|Green LED indicates DC is OK<br>| |Parallel Operation|-|Up to fve units, see installation manual| |**Environmental**||| |Operating Temperature (-25°C start-up)|°C|-20 to +60, derate linearly to 60% load from 50 to 60<br>Reverse air (/RF): -20 to +70, derate linearly to 50% load from 50 to 70| |Storage Temperature|°C|-30 to +75| |Humidity (non condensing)|%RH|Operating: 20 - 90, Storage: 10 - 90| |Cooling|-|Internal variable speed fan <45dBA noise| |Altitude|m|5,000| |Withstand Voltage (For 1 minute)|Vac|Input to Ground 2,000 (1xMoPP), Input to Output 4,000 (2xMoPP),<br>Output to Ground 1,500 (1xMoPP) for 1 min.| |Isolation Resistance|MΩ|>100 at 25°C, 70%RH & 500VDC| |Vibration (Non-operating)|-|10 - 55Hz: 19.6m/s2(sweep 1 min) X, Y, Z for 1 hour| |Shock|-|< 196.1 m/s2| |**Other**||| |Weight (Typ)|g|3,000| |Size (LxWxH)|mm|261 x 127 x 63| |Size (LxWxH)|Inches|10.28 x 5 x 2.48| |Connectors|-|Screw terminal input and output. Signal connectors JST S10B-PHDSS| |MTBF - Telcordia SR-332 issue 3*|Hours|769,670| |Warranty|yrs|7(1)| Notes See website for detailed specifications, test methods and installation manual (1) The Americas and EMEA regions: 7 years. Other regions: 5 years. See applicable regional terms of sale. (2) Derate linearly to 80% load from 90 to 85Vac input. Safety certified for AC input only *24V output model, 25°C ambient, full load, 230Vac input CUS1500M Series 3 **==> picture [517 x 34] intentionally omitted <==** ## **Outline Drawing (/RF version has airflow direction reversed)** **==> picture [510 x 342] intentionally omitted <==** To view the complete outline drawing please visit https://product.tdk.com/info/en/documents/2doutline_pdf/cus1500m_out.pdf CUS1500M Series 4 ## **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr-powersolutions@tdk.com www.emea.lambda.tdk.com/fr ## **Italy Sales Office** Tel +39 02 61 29 38 63 tlf.it-powersolutions@tdk.com www.emea.lambda.tdk.com/it ## **Netherlands** tlf.nl-powersolutions@tdk.com www.emea.lambda.tdk.com/nl ## **TDK-Lambda Europe GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de ## **Austria Sales Office** Tel: +43 2256 655 84 tlg.at-powersolutions@tdk.com www.emea.lambda.tdk.com/at ## **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch-powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com ## **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en ## **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com ## **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn ## **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com ## **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com ## **TDK-Lambda Europe GmbH** Tel: Tel. +45 3222 8086 tlg.dk-powersolutions@tdk.com www.emea.lambda.tdk.com/dk ## **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk ## **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit https://product.tdk.com/en/power/ CUS1500M_260702 April 7th, 2026 V5 CUS1500M Series 5
Updated at June 4, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →