CUS100ME-15/A
AC/DC Enclosed Power Supply (PSU), ITE & Medical, 1 Outputs, 100 W, 15 VDC, 6.66 A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:100W; Output Voltage - Output 1:15V; Output Current - Output 1:6.66A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage -
- SVHC: No SVHC (15-Jan-2018)
- Product Range: CUS100ME Series
- No. of Outputs: 1Outputs
- Output Power Max: 100W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 6.66A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 15VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 59.33 € |
| Current stock | 10+ |
| Lead time | 30 days |
CUS100ME Series 2 x 4” 100W AC-DC Power Supplies https://product.tdk.com/en/power/cus-m www.emea.lambda.tdk.com/cus100me The compact CUS100ME is packaged in the industry standard 2x4” footprint. The series can deliver 100W convection cooled at 50°C or up to 75W at 85°C with forced air. Conduction cooled, the CUS100M can deliver 100W at 70°C and 50W at 80°C. With Medical & ITE certifications, the unit can used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. Enclosure options include a baseplate, U channel or U channel with a cover. |**Features**|**Benefits**| |---|---| |• Up to 100W Utilizing Convection or Conduction Cooling|• Quiet Operation| |• Operation in Ambient Temperatures of up to 85°C|• Suitable for High Ambient Temperature Environments| |• Medical Certifications (2 x MOPP)|• Suitable for B and BF Type Medical Equipment| |• Class B Conducted and Radiated EMI|• Easier System EMC Compliance| |• Suitable for Class I and Class II installations|• Flexible Utilisation| |• Compact 2 x 4 x 1.24” Size|• Space Saving in End Equipment| |• Enclosure & Cooling Options|• Versatile Application| ## **Model Selector** |||Nominal|Nominal|Nominal|||Factory Set(1)||||Maximum|Maximum|||Maximum||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Model||Output|||||Output Voltage||||Current||||Power||| ||Voltage (V)|||Voltage (V)|Voltage (V)||Capability (V)|Capability (V)|||Convection (A)|||Convection (W)|||| |CUS100ME-12|||12||||12 - 13.2||||8.33||||100||| |CUS100ME-15|||15||||15 - 16.5||||6.66||||100||| |CUS100ME-18|||18||||18 - 19.8||||5.55||||100||| |CUS100ME-24|||24||||24 - 26.4||||4.16||||100||| |CUS100ME-28|||28||||28 - 30.8||||3.57||||100||| |CUS100ME-36|||36||||36 - 39.6||||2.77||||100||| |CUS100ME-48|||48||||48 - 50||||2.08||||100||| ||||||||||||||||||| |**CUS100ME-**|**12**|||**/**|||**U**||||**E**|||||**M**|| ||||||||||||||||||| |Output voltage 12, 15, 18, 24, 28, 36, 48||Output voltage 12, 15, 18, 24, 28, 36, 48|Output voltage 12, 15, 18, 24, 28, 36, 48|||blank open frame<br>U|blank open frame<br>U channel|||blank<br>E(2)|dual fuses<br>single input fuse in line||||blank JST connectors<br>M(2)Molex connectors||| |||||||A|U channel with cover||||||||||| |||||||B|baseplate||||||||||| Examples: CUS100ME-24/UEM, CUS100ME-12V5/A CUS100ME Series 1 **==> picture [516 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---| |Model<br>CUS100ME||| |**Input**||| |AC Input Voltage Range (Operating)|Vac|85 - 264(3)<br>| |Nominal Input Voltage Range|Vac|100 - 240(3)(Note: Safety certifed for 90 - 264Vac only)| |Input Frequency|Hz|47 - 63(4)| |Input Current (100Vac)|A|1.4| |Inrush Current at 230Vac (Cold Start)|A|<65| |Leakage Current|uA|<250 at 230Vac 63Hz| |Touch Current (Enclosure Leakage)|uA|<100| |Power Factor (115/230Vac)|-|>0.97 / 0.89 (100% load)| |Harmonic Compliance|-|Meets IEC61000-3-2 Class A| |No Load Power Consumption|W|<0.5 (230Vac)| |Hold Up Time|ms|>24| |Effciency<br>|%|Up to 94| |Average Effciency|%|>87. Measured at 25%, 50%, 75% and 100% load conditions| |Conducted & Radiated EMI|-|EN55032/EN55011-B (See application notes for conditions)| |Immunity|-|Compliant with EN60601-1-2;2015 (Ed4), see immunity table| |Insulation Class<br>|-|Construction suitable for Class I or Class II installation| |Safety Certifcations and Markings|-|IEC/EN/UL/CSA62368-1, 60950-1, IEC/EN60601-1, ES60601-1, CE Mark and UKCA Mark<br>Designed to meet IEC61010-1 and EN60335-1 compliant versions are available(2)| ## **Immunity** |**Immunity**|**Immunity**|**Immunity**|**Immunity**|**Immunity**| |---|---|---|---|---| |Test|Standard|Test Level|Criteria|Notes| |ESD|EN61000-4-2|4|A|-<br>| |Radiated Susceptibility|EN61000-4-3|3|A|Includes proximity feld requirements of EN60601-1-2:2015| |Electrical Fast Transient Burst|EN61000-4-4|4|A|(AC Port, 5kHz and 100kHz)| |Surge|EN61000-4-5|3|A|-| |Conducted Susceptibility<br>|EN61000-4-6|3|A|-| |Magnetic felds|EN61000-4-8|4|A|-| |Voltage Dips and<br>Input Interuptions|EN61000-4-11<br>Class 3 Industrial,<br>incl EN55024<br>(100Vac)|0% for 1/2 cycle<br>0% for 1 cycle<br>40% for 10/12 cycles<br>70% for 25/30 cycles<br>80% for 250/300 cycles<br>0% for 250/300 cycles|A<br>A<br>B<br>A<br> <br>A<br>B|-<br>-<br>-<br>-<br>-<br>-| ||EN61000-4-11<br>Class 3 Industrial,<br>incl EN55024<br>(240Vac)|<br>0% for 1/2 cycle<br>0% for 1 cycle<br>40% for 10/12 cycles<br>70% for 25/30 cycles<br>80% for 250/300 cycles<br>0% for 250/300 cycles|A<br>A<br>A<br>A<br> <br>A<br>B|-<br>-<br>-<br>-<br>-<br>-| ||EN60601-1-2:2015<br>(100Vac)|<br>0% for 1/2 cycle<br>0% for 1 cycle<br>70% for 25/30 cycles<br>0% for 250/300 cycles|A<br>A<br>A<br>B|-<br>-<br>-<br>-| ||EN60601-1-2:2015<br>(240Vac)|<br>0% for 1/2 cycle<br>0% for 1 cycle<br>70% for 25/30 cycles<br>0% for 250/300 cycles|A<br>A<br>A<br>B|-<br>-<br>-<br>-| |Ringwave Test|EN61000-4-12|3|A|-| |Voltage Fluctuations|EN61000-4-14|Class 3|A|-| |SEMI F47 Line Dip|SEMI F47|-|-|Consult factory| CUS100ME Series 2 **==> picture [516 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---| |Model<br>CUS100ME||| |**Output**||| |Line Regulation|%|<0.5 (90 - 264Vac)| |Load Regulation|%|<1 (0 - 100% load)| |Ripple & Noise<br>|%|<1% of nominal output for operating temperatures above 0°C<br>At -20°C: 12V model <4%, 15V & 18V model <3%, other models <2%| |Temperature Coeffcient|%/°C|±0.02%/°C| |Minimum Load|-|No minimum load required| |Overcurrent Protection|%|110 to 190%. Hiccup mode, automatic recovery| |Overvoltage Protection|-|115-140% of standard output voltage for each model, 48V model max 60V.<br>Latching (unit shutdown), cycle AC input to reset| |Remote Sense|-|None| |Fan Supply|-|None| |Parallel Operation|-|Not possible| |Series Operation|-|Please contact Technical Sales for guidance| |**Environmental**||| |Operating Temperature (-30°C start-up)|°C|-20°C to +85°C, see derating curves below for operation above +50°C| |Storage Temperature|°C|-40°C to +85°C| |Humidity (non condensing)|%RH|5 - 95%RH| |Cooling|-|Convection, conduction or forced air cooling. See derating curves below| |Altitude|m|5,000m| |Withstand Voltage|Vac|Input to Ground 1.5kVAC (1xMOPP), Input to Output 4kVAC (2xMOPP),<br>Output to Ground 1.5kVAC (1xMOPP)| |Isolation Resistance|MΩ|>100MΩ at 25°C, 70%RH & 500VDC| |Vibration (Non Operating)|-|2G, 10-500Hz for 1 hour| |Shock (Non Operating)|-|30G, 11ms half sine| |**Other**||| |Weight|g|Open Frame: 180g; /U: 240g; /A: 255g; /B: 220g| |Size (WxLxH)|mm|Open frame version: 50.8 x 101.6 x 31.5| |Size (WxLxH)|Inches|Open frame version: 2 x 4 x 1.24| |Connectors|-|Input: JST B2P3-VH, Output: JST B6P-VH| |Warranty|yrs|5| Notes: See website for detailed specifications, test methods and installation manual. Specification parameters apply at 25°C ambient temperature unless otherwise stated. (1) Output voltage is factory set and not user adjustable. Non-standard output versions may be subject to minimum order quantities and variations to specification. For all non-standard output voltage settings please consult Sales. (2) Subject to Minimum Order Quantities. Please contact Sales (3) Derate linearly to 90% load from 90 to 85Vac input. (4) For operation at 440Hz please consult Technical Sales. CUS100ME Series 3 ## **Outline drawing CUS100ME (Open Frame unit)** CUS100ME Series 4 ## **Outline drawing CUS100ME/U (U Channel) Option** CUS100ME Series 5 ## **Outline drawing CUS100ME/B (Baseplate) Option** CUS100ME Series 6 ## **Outline drawing CUS100ME/A (U Channel with cover) Option** CUS100ME Series 7 ## **Output Power vs Ambient Temperature (Convection/Conduction Cooled)** **==> picture [291 x 391] intentionally omitted <==** **----- Start of picture text -----**<br> @ 90Vac to 264Vac, derate by 10% at 85Vac<br>—— Open frame and /8 convection cooling,<br>—_ /U - U chassis option, convection cooling *4)<br>= = /A-U chassis with top cover, convection<br>—_ /U and /B - U chassis and Baseplate option,<br>= = /A- U chassis with top cover, cold plate<br>100<br>ag - : : h<br>!<br>10 - : |<br>Oo a 4. 4 4. n rn n<br>-20 -10 i] 10 20 30 40<br>Ambient Temperature (°C)<br>Output Power (W)<br>**----- End of picture text -----**<br> CUS100ME Series 8 **==> picture [510 x 365] intentionally omitted <==** **----- Start of picture text -----**<br> Output Power vs Ambient Temperature (Forced Air Cooled)<br>Ce<br>@ 90Vac to 264Vac, derate by 10% at 85Vac<br>—— Airflow im/'s *3)<br>100<br>80 +<br>70 =<br>60 - |<br>30<br>20<br>40 4 .<br>o | : : : :<br>-20 -10 0 10 20 30 40 50 60 fo &0 90)<br>Ambient Temperature (°C)<br>Output Power (W)<br>**----- End of picture text -----**<br> Notes: 1) 50mm above surface - 2) Not applicable - 3) Tested with airflow direction G (see Application Note) - 4) 50mm above surface, orientation A (see Application Note) no additional coldplate - 5) U chassis or Baseplate fixed on a coldplate (system chassis), orientation A (see Application Note) - /B baseplate option performance is the same as with the U chassis option for coldplate cooling CUS100ME Series 9 **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr-powersolutions@tdk.com www.emea.lambda.tdk.com/fr **Italy Sales Office** Tel +39 02 61 29 38 63 tlf.it-powersolutions@tdk.com www.emea.lambda.tdk.com/it **Netherlands** tlf.nl-powersolutions@tdk.com www.emea.lambda.tdk.com/nl **TDK-Lambda Europe GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de **Austria Sales Office** Tel: +43 2256 655 84 tlg.at-powersolutions@tdk.com www.emea.lambda.tdk.com/at **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch-powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn ## **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com ## **TDK-Lambda Europe GmbH** Tel: Tel. +45 3222 8086 tlg.dk-powersolutions@tdk.com www.emea.lambda.tdk.com/dk **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit https://product.tdk.com/en/power/ CUS100ME_260451 May 29th, 2025 V9 CUS100ME Series 10
Updated at June 4, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →