CSP-3000-250
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 3 kW, 250 VDC, 12 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: CSP-3000 Series
- No. of Outputs: 1Outputs
- Output Power Max: 3kW
- Input Voltage VAC: 180V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 12A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 250VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 452.23 € |
| Current stock | 10+ |
| Lead time | 30 days |
**CSP - 3000 series** 3000W Power Supply with Single Output Dimension L * W * H 278 * 177.8 * 63.5(2U) mm 10.9 * 7 * 2.5 (2U) inch 278 * 177.8 * 63.5(2U) mm 10.9 * 7 * 2.5 (2U) inch nan) (> ARs UL62368-1 @ FAL CB IEC62368-1 CE EN62368-1 ■ **Features** ■ Applications • AC input 180~264VAC • Factory control or automation • Built-in active PFC function • Test and measurement • High efficiency up to 93% • Laser related machine • Forced air cooling by built-in DC fans • UV curing equipment • Output voltage / current programmable • Fish lamp • Active current sharing up to 9O00W(2+1) • Burn-in facility • Built-in remote ON-OFF control / auxiliary power / power OK signal • **==> picture [13 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> •<br>•<br>**----- End of picture text -----**<br> **==> picture [17 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> ℃ **==> picture [118 x 29] intentionally omitted <==** **----- Start of picture text -----**<br> ■ Model Encoding<br>CSP - 3000 - 250<br>**----- End of picture text -----**<br> _File Name:CSP-3000-SPEC 2019-07-17_ **CSP - 3000 series** 3000W Power Supply with Single Output ## **SPECIFICATION** ||**CSP-3000-120**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**CONSTANT CURRENT REGION**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.4**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**CURRENT SHARING**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>120V<br>25A<br>0 ~ 25A<br>3000W<br>800mVp-p<br>90 ~ 120V<br>±1.0%<br>±0.5%<br>±0.5%<br>1000ms, 80ms / 230VAC at full load<br>10ms at full load<br>180 ~ 264VAC 254 ~ 370VDC<br>47~63Hz<br>92%<br>20A/180VAC 16A/230VAC<br>Cold start 60A/230VAC<br><0.3mA / 240VAC<br>105 ~ 120% rated output power<br>127 ~ 150V<br>Constant current limiting with delay shutdown after 3 seconds, re-power to recover<br>265 ~ 315V<br>50 ~ 250V<br>420 ~ 500V<br>80 ~ 400V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover<br>-20 ~ +60℃(Refer to "Derating Curve")<br>24 ~ 120V<br>Please refer to the Function Manual.<br>20 ~ 90% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH non-condensing<br>±0.05%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>223.8K hrs min. Telcordia SR-332 (Bellcore) ; 75.1K hrs min. MIL-HDBK-217F (25℃)<br>278*177.8*63.5mm (L*W*H)<br>4Kg; 4pcs/16Kg/1.81CUFT<br>92.5%<br>93%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>1000mVp-p<br>125 ~ 250V<br>1200mVp-p<br>200 ~ 400V<br>250V<br>12A<br>0 ~ 12A<br>3000W<br>400V<br>7.5A<br>0 ~ 7.5A<br>3000W<br>**CSP-3000-250**<br>**CSP-3000-400**<br>1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedloadand25℃ofambienttemperature.<br>2.InthePVMode:Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor.<br>3.Tolerance:includessetuptolerance,lineregulationandloadregulation.<br>4.Turnofftheoutputwheninputvoltageislessthan160VAC.<br>5.<br>Thepowersupplyisconsideredacomponentwhichwillbeinstalledintoafinalequipment.AlltheEMCtestsarebeenexecutedbymountingtheunit on<br>a<br>mm*<br>mmmetalplatewith1mmofthickness.Thefinalequipmentmustbere-confirmedthatitstillmeetsEMCdirectives.<br>720<br>360<br>Forguidanceonhowto<br>performtheseEMCtests,pleasereferto“EMItestingofcomponentpowersupplies.”(asavailableonhttp://www.meanwell.com)<br>6.Theambienttemperaturederatingof3.5℃/1000mwithfanlessmodelsandof5℃/1000mwithfanmodelsforoperatingaltitudehigherthan2000m(6500ft).<br>**POWER FACTOR (Typ.)**<br>PF≧0.95/230VAC at full load<br>**SAFETY STANDARDS**<br>UL62368-1,Dekra seal EN62368-1, EAC TP TC004, GB4943.1<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**ENVIRONMENT**<br>**SAFETY &**<br>**FUNCTION**<br>**EMC**<br>**(Note 5)**<br>**PROTECTION**<br>**ALARM SIGNAL OUTPUT**<br>**REMOTE ON-OFF CONTROL**<br>**AUXILIARY POWER(AUX)**<br>Please refer to the Function Manual<br>Power OK signal. Please refer to the Function Manual<br>12V@0.4A<br>**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV)**<br>Please refer to the Function Manual.<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61204-3, EN61000-6-2<br>**Standard**<br>**Standard**<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class A<br>Class A<br>-----<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line<br>EN55032(CISPR32)/EN55011(CISPR11)<br>EN55032(CISPR32)/EN55011(CISPR11)<br>**SHORT CIRCUIT**<br>Shut down and latch off o/p voltage, re-power on to recover|**CSP-3000-120**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**CONSTANT CURRENT REGION**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.4**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**CURRENT SHARING**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>120V<br>25A<br>0 ~ 25A<br>3000W<br>800mVp-p<br>90 ~ 120V<br>±1.0%<br>±0.5%<br>±0.5%<br>1000ms, 80ms / 230VAC at full load<br>10ms at full load<br>180 ~ 264VAC 254 ~ 370VDC<br>47~63Hz<br>92%<br>20A/180VAC 16A/230VAC<br>Cold start 60A/230VAC<br><0.3mA / 240VAC<br>105 ~ 120% rated output power<br>127 ~ 150V<br>Constant current limiting with delay shutdown after 3 seconds, re-power to recover<br>265 ~ 315V<br>50 ~ 250V<br>420 ~ 500V<br>80 ~ 400V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover<br>-20 ~ +60℃(Refer to "Derating Curve")<br>24 ~ 120V<br>Please refer to the Function Manual.<br>20 ~ 90% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH non-condensing<br>±0.05%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>223.8K hrs min. Telcordia SR-332 (Bellcore) ; 75.1K hrs min. MIL-HDBK-217F (25℃)<br>278*177.8*63.5mm (L*W*H)<br>4Kg; 4pcs/16Kg/1.81CUFT<br>92.5%<br>93%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>1000mVp-p<br>125 ~ 250V<br>1200mVp-p<br>200 ~ 400V<br>250V<br>12A<br>0 ~ 12A<br>3000W<br>400V<br>7.5A<br>0 ~ 7.5A<br>3000W<br>**CSP-3000-250**<br>**CSP-3000-400**<br>1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedloadand25℃ofambienttemperature.<br>2.InthePVMode:Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor.<br>3.Tolerance:includessetuptolerance,lineregulationandloadregulation.<br>4.Turnofftheoutputwheninputvoltageislessthan160VAC.<br>5.<br>Thepowersupplyisconsideredacomponentwhichwillbeinstalledintoafinalequipment.AlltheEMCtestsarebeenexecutedbymountingtheunit on<br>a<br>mm*<br>mmmetalplatewith1mmofthickness.Thefinalequipmentmustbere-confirmedthatitstillmeetsEMCdirectives.<br>720<br>360<br>Forguidanceonhowto<br>performtheseEMCtests,pleasereferto“EMItestingofcomponentpowersupplies.”(asavailableonhttp://www.meanwell.com)<br>6.Theambienttemperaturederatingof3.5℃/1000mwithfanlessmodelsandof5℃/1000mwithfanmodelsforoperatingaltitudehigherthan2000m(6500ft).<br>**POWER FACTOR (Typ.)**<br>PF≧0.95/230VAC at full load<br>**SAFETY STANDARDS**<br>UL62368-1,Dekra seal EN62368-1, EAC TP TC004, GB4943.1<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**ENVIRONMENT**<br>**SAFETY &**<br>**FUNCTION**<br>**EMC**<br>**(Note 5)**<br>**PROTECTION**<br>**ALARM SIGNAL OUTPUT**<br>**REMOTE ON-OFF CONTROL**<br>**AUXILIARY POWER(AUX)**<br>Please refer to the Function Manual<br>Power OK signal. Please refer to the Function Manual<br>12V@0.4A<br>**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV)**<br>Please refer to the Function Manual.<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61204-3, EN61000-6-2<br>**Standard**<br>**Standard**<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class A<br>Class A<br>-----<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line<br>EN55032(CISPR32)/EN55011(CISPR11)<br>EN55032(CISPR32)/EN55011(CISPR11)<br>**SHORT CIRCUIT**<br>Shut down and latch off o/p voltage, re-power on to recover|**CSP-3000-120**|**CSP-3000-250**|**CSP-3000-400**| |---|---|---|---|---|---| |||**DC VOLTAGE**|120V|250V|400V| |||**RATED CURRENT**|25A|12A|7.5A| |||**CURRENT RANGE**|0 ~ 25A|0 ~ 12A|0 ~ 7.5A| |||**RATED POWER**|3000W|3000W|3000W| |||**RIPPLE & NOISE (max.)Note.2**|800mVp-p|1000mVp-p|1200mVp-p| |||**CONSTANT CURRENT REGION**|90 ~ 120V|125 ~ 250V|200 ~ 400V| |||**VOLTAGE TOLERANCENote.3**|±1.0%|±1.0%|±1.0%| |||**LINE REGULATION**|±0.5%|±0.5%|±0.5%| |||**LOAD REGULATION**|±0.5%|±0.5%|±0.5%| |||**SETUP, RISE TIME**|1000ms, 80ms / 230VAC at full load||| |||**HOLD UP TIME (Typ.)**|10ms at full load||| |||**VOLTAGE RANGENote.4**|180 ~ 264VAC 254 ~ 370VDC||| |||**FREQUENCY RANGE**|47~63Hz||| |||**POWER FACTOR (Typ.)**|PF≧0.95/230VAC at full load||| |||**EFFICIENCY (Typ.)**|92%|92.5%|93%| |||**AC CURRENT (Typ.)**|20A/180VAC 16A/230VAC||| |||**INRUSH CURRENT (Typ.)**|Cold start 60A/230VAC||| |||**LEAKAGE CURRENT**|<0.3mA / 240VAC||| |||**SHORT CIRCUIT**|Shut down and latch off o/p voltage, re-power on to recover||| |||**OVER CURRENT**|105 ~ 120% rated output power<br>Constant current limiting with delay shutdown after 3 seconds, re-power to recover||| |||**OVER VOLTAGE**|127 ~ 150V<br>265 ~ 315V<br>420 ~ 500V<br>Protection type : Shut down o/p voltage, re-power on to recover||| |||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover||| |||**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV)**|50 ~ 250V<br>80 ~ 400V<br>24 ~ 120V<br>Please refer to the Function Manual.||| |||**CURRENT SHARING**|Please refer to the Function Manual.||| |||**AUXILIARY POWER(AUX)**|12V@0.4A||| |||**REMOTE ON-OFF CONTROL**|Please refer to the Function Manual||| |||**ALARM SIGNAL OUTPUT**|Power OK signal. Please refer to the Function Manual||| |||**WORKING TEMP.**|-20 ~ +60℃(Refer to "Derating Curve")||| |||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +85℃, 10 ~ 95% RH non-condensing||| |||**TEMP. COEFFICIENT**|±0.05%/℃(0 ~ 50℃)||| |||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes||| |||**SAFETY STANDARDS**|UL62368-1,Dekra seal EN62368-1, EAC TP TC004, GB4943.1||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC||| |||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH||| |||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|**Parameter**|**Standard**|**Test Level / Note**| ||||Conducted|EN55032(CISPR32)/EN55011(CISPR11)|Class A| ||||Radiated|EN55032(CISPR32)/EN55011(CISPR11)|Class A| ||||Harmonic Current|EN61000-3-2|-----| ||||Voltage Flicker|EN61000-3-3|-----| ||||EN55024 , EN61204-3, EN61000-6-2||| ||||**Parameter**|**Standard**|**Test Level / Note**| ||||ESD|EN61000-4-2|Level 3, 8KV air ; Level 2, 4KV contact| ||||Radiated|EN61000-4-3|Level 3| ||||EFT / Burst|EN61000-4-4|Level 3| ||||Surge|EN61000-4-5|Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line| ||||Conducted|EN61000-4-6|Level 3| ||||Magnetic Field|EN61000-4-8|Level 4| ||||Voltage Dips and Interruptions|EN61000-4-11|>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods| ||||223.8K hrs min. Telcordia SR-332 (Bellcore) ; 75.1K hrs min. MIL-HDBK-217F (25℃)||| |||**DIMENSION**|278*177.8*63.5mm (L*W*H)||| |||**PACKING**<br>4Kg; 4pcs/16Kg/1.81CUFT<br>1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedloadand25℃ofambienttemperature.<br>2.InthePVMode:Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor.<br>3.Tolerance:includessetuptolerance,lineregulationandloadregulation.<br>4.Turnofftheoutputwheninputvoltageislessthan160VAC.<br>5.<br>Thepowersupplyisconsideredacomponentwhichwillbeinstalledintoafinalequipment.AlltheEMCtestsarebeenexecutedbymountingtheunit on<br>a<br>mm*<br>mmmetalplatewith1mmofthickness.Thefinalequipmentmustbere-confirmedthatitstillmeetsEMCdirectives.<br>720<br>360<br>Forguidanceonhowto<br>performtheseEMCtests,pleasereferto“EMItestingofcomponentpowersupplies.”(asavailableonhttp://www.meanwell.com)<br>6.Theambienttemperaturederatingof3.5℃/1000mwithfanlessmodelsandof5℃/1000mwithfanmodelsforoperatingaltitudehigherthan2000m(6500ft).|||| _File Name:CSP-3000-SPEC 2019-07-17_ **CSP - 3000 series** ## 3000W Power Supply with Single Output ## **Block Diagram** **==> picture [461 x 169] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 85KHz<br>PWM fosc : 100KHz<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& +V-V<br>PFC O.V.P.<br>CONTROL O.L.P.<br>PWM<br>DETECTION<br>O.T.P. CONTROL CIRCUIT P OK<br>LOAD CONTROLREMOTE RC<br>SHARING<br>CS<br>FAN<br>AUX RECTIFIERS<br>POWER & AUX POWER<br>FILTER (12V/0.4A)<br>**----- End of picture text -----**<br> **==> picture [105 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> Static Characteristics<br>**----- End of picture text -----**<br> ## **Derating Curve** **==> picture [487 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>100<br>90<br>80<br>80<br>70 60<br>60 50<br>40<br>50<br>20<br>40<br>180 190 200 210 220 250 264 -20 0 10 20 30 40 50 60 65 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ )<br>INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> ## **Efficiency vs Load (400V Model)** **==> picture [245 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> 94<br>92<br>90<br>88<br>86<br>84<br>82<br>80<br>78<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>EFFICIENCY (%)<br>**----- End of picture text -----**<br> - ※ The curve above is measured at 230VAC. _File Name:CSP-3000-SPEC 2019-07-17_ **CSP - 3000 series** 3000W Power Supply with Single Output ## **DRIVING METHODS OF LED MODULE** ※ I-V Operating Area ◎◎ **CSP-3000-120** ## ◎ **CSP-3000-250** **==> picture [443 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 130V 260V<br>1.36A, 250V 9A,250V<br>125V 12A, 250V<br>2.4A, 120V 15A,120V 240V<br>120V 25A, 120V<br>220V<br>115V<br>110V 200V<br>105V 180V<br>17A, 176.5V<br>100V 30A, 100V<br>160V<br>95V<br>140V<br>90V 30A, 90V<br>85V 2.4A, 90V 120V 17A, 125V<br>1.36A, 125V<br>80V 100V<br>0A 5A 10A 15A 20A 25A 30A 35A 0A 3A 6A 9A 12A 15A 18A<br>Recommended High Performance Region Allowed Operational Region Recommended High Performance Region Allowed Operational Region<br>**----- End of picture text -----**<br> Recommended High Performance Region Allowed Operational Region ## ◎ **CSP-3000-400** **==> picture [211 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> 430V<br>0.8A, 400V 5.25A,400V 7.5A, 400V<br>400V<br>370V<br>340V<br>10A, 300V<br>310V<br>280V<br>250V<br>220V<br>190V<br>0.8A, 200V 10A, 200V<br>160V<br>130V<br>100V<br>0A 1.5A 3A 4.5A 6A 7.5A 9A 10.5A 12A 13.5A 15A<br>Recommended High Performance Region Allowed Operational Region<br>**----- End of picture text -----**<br> _File Name:CSP-3000-SPEC 2019-07-17_ **CSP - 3000 series** ## 3000W Power Supply with Single Output ## **Function Manual** ## **1. Output Voltage/Current Programming** **==> picture [419 x 194] intentionally omitted <==** **----- Start of picture text -----**<br> ※ Mode Setting<br>CN1:<br>CONDITION MODE FUNCTION<br>SHORT PV MODE Output Voltage Programming<br>PIN5/PIN6<br>OPEN PC MODE Output Current Programming<br> PIN6<br> PIN5<br> PV/PC MODE CHOSE<br>CN1<br>max. PV/PC SET(SVR2)<br> PIN8<br> PIN7 PV/PC SET PIN6<br> PIN5 PV/PC ADJUST<br>CN2<br>**----- End of picture text -----**<br> ## ※ PV/PC Set adjustment - In the PV mode, the adjustable resistor (SVR2) can set the output voltage, the output voltage can be adjusted to 20-100% of the rated voltage. - In the PV mode, the pin7/pin8 at the CN2 terminal only accepts the input DC voltage to set the output voltage, - and the output voltage can be trimmed to 20-100% of the rated voltage. - ◎ When pin7/pin8 signal<2V,output voltage≧rated voltage 10%. - In the PC mode, the adjustable resistor (SVR2) can set the maximum constant current point. - In the PC mode, the maximum output constant current value can be set when the pin7/pin8 of the CN2 terminal accepts only the input DC voltage. - The output maximum constant current value can be trimmed by the CN2 terminal pin7/pin8 voltage (Vs), the relationship between voltage and current: Imax. *Vs/10V - The adj. min. current≧8%Imax, refer to PC range. - For fast output response, it is recommended to adjust through CN2 terminal PIN5/PIN6, - applying additive 10V PWM signal(frequency range 500Hz~1KHz). **==> picture [314 x 299] intentionally omitted <==** **----- Start of picture text -----**<br> V I<br>100 100<br>80 Non-Linear MODEL 120V 250V 400V 80 Non-Linear<br>60 PV Range 24 ~ 120V 50 ~ 250V 80 ~ 400V 60<br>40 40<br>20 20<br>(V)<br>2 4 6 8 10 2 4 6<br>EXTERNAL VOLTAGE (DC)<br>Vout<br>100<br>80 Non-Linear<br>60<br>40<br>MODEL 120V 250V 400V<br>8 PC Range 2.4 ~ 30A(max.) 1.4~ 17A(max.) 0.8 ~ 10A(max.)<br>0.8 4 6 8 10 V<br>8 40 60 80 100 %<br>EXTERNAL VOLTAGE (DC)/PWM<br>OUTPUT VOLTAGE SET (%) OUTPUT CURRENT SET (%)<br>OUTPUT VOLTAGE / CURRENT ADJ. (%)<br>**----- End of picture text -----**<br> **==> picture [255 x 132] intentionally omitted <==** **----- Start of picture text -----**<br> I<br>100<br>80 Non-Linear MODEL 120V 250V 400V<br>60 PC Range 6 ~ 30A(max.) 3.4~ 17A( max.) 2 ~ 10A(max.)<br>40<br>20<br>(V)<br>2 4 6 8 10<br>EXTERNAL VOLTAGE (DC)<br>OUTPUT CURRENT SET (%)<br>**----- End of picture text -----**<br> _File Name:CSP-3000-SPEC 2019-07-17_ **CSP - 3000 series** 3000W Power Supply with Single Output ## **2.Remote ON-OFF** ※ Remote ON-OFF is activated by the configuration with respect to CN1 as shown in the following diagram. **==> picture [51 x 24] intentionally omitted <==** **----- Start of picture text -----**<br> PIN3 RC<br> PIN1 RCG<br>CN1<br>**----- End of picture text -----**<br> Example 2.2(A): Using external voltage source **==> picture [175 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> AUX<br>12V<br>1KΩ RC<br>Internal<br>12V typ. SW<br>RCG<br>AUXG<br>**----- End of picture text -----**<br> Example 2.2(B): Using internal 12V auxiliary output **==> picture [380 x 297] intentionally omitted <==** **----- Start of picture text -----**<br> AUX<br>1KΩ RC<br>Internal<br>12V typ.<br>RCG<br>SW<br>AUXG<br>Example 2.2(C): Using internal 12V auxiliary output<br>AUX<br>1KΩ<br>1KΩ RC<br>Internal<br>12V typ. SW<br>RCG<br>AUXG<br>◎ Connection Method<br>Example 2.2(A) Example 2.2(B) Example 2.2(C)<br>Power supply output ON SW Open(open) SW Open(open) SW Close(short)<br>SW Logic<br>Power supply output OFF SW Close(short) SW Close(short) SW Open(open)<br>**----- End of picture text -----**<br> _File Name:CSP-3000-SPEC 2019-07-17_ **CSP - 3000 series** 3000W Power Supply with Single Output ## **3.Alarm Signal Output** ※ Alarm signal is sent out through " _P OK_ " & " _P OK GND_ " and _P OK2 & P OK GND2_ pins on CN1. Please acknowledge an external voltage source is required for this function. **==> picture [445 x 331] intentionally omitted <==** **----- Start of picture text -----**<br> PIN9(P-OK-GND) PIN4(P-OK-GND-2)<br>PIN7(P-OK) PIN2(P-OK-2)<br>CN1<br>Function Description Output of alarm(P OK, Relay Contact) Output of alarm(P OK2, TTL Signal)<br>The signal is "Low" when the power supply is above Low Low<br>80% of the rated output voltage, or, say, Power OK (0.5V max at 500mA) (0.5V max at 10mA)<br>P OK<br>The signal turns to be "High" when the power supply<br>High or open High or open<br>is under 80% of the rated output voltage, or, say,<br>Power Fail (External applied voltage, 500mA max.) (External applied voltage, 10mA max.)<br>Table 3.1 Explanation of alarm<br>P OK P OK2<br>R R<br>V 0.1uF V<br>P OK GND External voltage and R P OK GND2 External voltage and R<br>(The max. sink is 500mA and 20V) (The max. sink is 10mA and 30V)<br>Fig. 3.2 Internal circuit of P OK (Relay, total is 10W) Fig. 3.3 Internal circuit of P OK2 (Open collector method)<br>**----- End of picture text -----**<br> _File Name:CSP-3000-SPEC 2019-07-17_ **CSP - 3000 series** ## 3000W Power Supply with Single Output ## **4.Current Sharing** CSP-3000 has the built-in active current sharing function and can be connected in parallel, up to 3 units, to provide higher output power as exhibited below : - ※ The power supplies should be paralleled using short and large diameter wiring and then connected to the load. - ※ Difference of output voltages among parallel units should be less than 0.2V(Can Fine tune by SVR1). - ※ The total output current must not exceed the value determined by the following equation: Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9 - ※ When out current<( 50% rate current)×(Number of unit), the current shared among units may not be fully balanced. ◎ _CS+/CS-_ on CN1 are connected mutually in parallel(Note:CS+/CS- do not reverse connection). ◎ Under parallel operation, the "PV/PC" function is not available. **==> picture [446 x 426] intentionally omitted <==** **----- Start of picture text -----**<br> No.1(Master) Current Sharing condition<br>max. Output Voltage ADJ(SVR1)<br>+V<br>-V<br>+V<br>No.2(Slave) Load<br>-V<br>+V<br>-V<br>No.3(Slave)<br>+V<br>-V<br>**----- End of picture text -----**<br> _File Name:CSP-3000-SPEC 2019-07-17_ ## 3000W Power Supply with Single Output ## **CSP - 3000 series** **==> picture [504 x 595] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>Case No.982B Unit:mm<br>278<br>236.3 27<br>1 1 CN1 CN2<br>10 8 6 4 2 8 6 4 2<br>8-M4(Both Sides) L=5mm<br>9 7 5 3 1 7 5 3 1<br>236.3 27 19max.<br>4-M4 L=5mm<br>1 1<br>OUTPUT<br>Air flow<br>direction<br>INPUT<br>1 1<br>16max.<br>※ Mounting Instruction Chassis of CSP-3000<br>Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque Mounting Surface<br>1 M4 5mm 7~10Kgf-cm<br>※ Control Pin No. Assignment (CN1) : FJY 964-20531-180016 or equivalent<br>Mounting Screw<br>L<br>Mating Housing FJY 3521-1000205-1803 or equivalent<br>9 10<br>Terminal FJY 256-210000-22119 or equivalent<br>1 2<br>◎ CN1 are connected internally.<br>Pin No. Function Description<br>1 RCG Remote ON-OFF Ground<br>2 P-OK-2 Power OK Signal(TTL Signal)<br>3 RC Remote ON-OFF<br>4 P-OK-GND-2 Power OK Ground<br>5 GND PV/PC Mode Choose Ground<br>6 Mode PV/PC Mode Choose<br>7 P-OK Power OK Signal(Relay Contact)<br>8 CS+ Current Sharing Signal+<br>9 P-OK GND Power OK Ground<br>10 CS- Current Sharing Signal-<br>12.5<br>38 63.5<br>7.9<br>16<br>13<br>162 177.8<br>10<br>13<br>**----- End of picture text -----**<br> _File Name:CSP-3000-SPEC 2019-07-17_ **CSP - 3000 series** 3000W Power Supply with Single Output ※Control Pin No. Assignment (CN2) : FJY 964-20431-180016 or equivalent 7 8 Mating Housing FJY 3521-1000204-1803 or equivalent 1 2 Terminal FJY 256-210000-22119 or equivalent |**Pin No.**|**Function**|**Description**| |---|---|---| |1|12V AUXG|Auxiliary output GND| |2|12V AUX+|Auxiliary output+| |3|NC|| |4|NC|| |5|PV/PC+|PV/PC adjust+ for fast output response| |6|PV/PC-|PV/PC adjust- for fast output response| |7|SET+|PV/PC set+| |8|SET-|PV/PC set-| ※AC Input Terminal Pin No. Assignment Pin No. Assignment Diagram Maximum mounting torque 1 AC/L 2 AC/N 18Kgf-cm 3 FG ※DC Output Terminal Pin No. Assignment Pin No. Assignment Diagram Maximum mounting torque 1 V- 18Kgf-cm 2 V+ ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:CSP-3000-SPEC 2019-07-17_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →