CSLA1DJ
SENSOR, -225A TO 225A, SINK/SOURCE
- Manufacturer: HONEYWELL
- Product type: Current Sensors
- SVHC: No SVHC (07-Jul-2017)
- Accuracy: -
- Product Range: CSLA Series
- Response Time: 3µs
- Primary Current: 225A
- Sensor Mounting: Through Hole
- Measured Current: AC / DC
- Sensor Output Type: Sink / Source
- Supply Voltage Range: 8VDC to 16VDC
- Supply Voltage DC Max: 16V
- Supply Voltage DC Min: 8V
- Current Sensor Technology: Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -25°C
- Current Measuring Range AC: -225A to 225A
- Current Measuring Range DC: -225A to 225A
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 27.93 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Interactive Catalog Replaces Catalog Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive Catalog. The Interactive Catalog is a power search tool that makes it easier to find product information. It includes more installation, application, and technical information than ever before. **Click this icon to try the new Interactive Catalog.** **Solid State Sensors** Linear Current Sensors CS Series ## **FEATURES** Linear output AC or DC current sensing Through-hole design Fast response time Output voltage isolation from input Minimum energy dissipation Maximum current limited only by conductor size Adjustable performance and built-in temperature compensation assures reliable operation Accurate, low cost sensing Operating temperature range –25 to 85 ° C Housing: PET polyester ## **LINEAR CURRENT SENSORS** MICRO SWITCH CS series linear current sensors incorporate our 91SS12-2 and SS94A1linear output Hall effect transducer (LOHET[TM] ). The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configuration as shown in mounting dimension figures 1, 1a, 2 and 2a. Normal mounting is with 0.375 inch long 4-40 screw and square nut (not provided) inserted in the housing or a 6-20 self-tapping screw. The combination of the sensor, flux collector, and housing comprises the holder assembly. These sensors are ratiometric. ## **ORDER GUIDE — BOTTOM MOUNT WITH 9SS SENSOR, SOURCE OUTPUT** |**Catalog**<br>**Listing**|**Mtg.**<br>**Dim.**<br>**Fig.**|**Supply**<br>**Volt.**<br>**(Volts DC)**|**Supply**<br>**Current**<br>**(mA Max.)**|**Sensed**<br>**Current**<br>**(Amps**<br>**Peak)**|**Offset**<br>**Volt.**<br>**(Volts**±**10%)**|**Sensitivity**<br>**mV N***<br>**At 12 VDC**|**Sensitivity**<br>**mV N***<br>**At 12 VDC**|**Offset**<br>**Shift**<br>**(%/**°**C)**|**Response**<br>**Time**<br>**(**µ**Sec.)**| |---|---|---|---|---|---|---|---|---|---| |||||||**Nominal**|±**TOL**||| |**CSLA1CD**|1|8 to 16|19|57|Vcc/2|49.6|5.8|±.05|3| |**CSLA1CE**|1|8 to 16|19|75|Vcc/2|39.4|4.4|±.05|3| |**CSLA1DE**|2|8 to 16|19|75|Vcc/2|39.1|4.8|±.05|3| |**CSLA1CF**|1|8 to 16|19|100|Vcc/2|29.7|2.7|±.05|3| |**CSLA1DG**|2|8 to 16|19|120|Vcc/2|24.6|2.1|±.05|3| |**CSLA1CH**|1|8 to 16|19|150|Vcc/2|19.6|1.8|±.05|3| |**CSLA1DJ**|2|8 to 16|19|225|Vcc/2|13.2|1.2|±.05|3| |**CSLA1EJ**|1a|8 to 16|19|225|Vcc/2|13.2|1.5|±.05|3| |**CSLA1DK**|2|8 to 16|19|325|Vcc/2|9.1|1.7|±.05|3| |**CSLA1EK**|1a|8 to 16|19|325|Vcc/2|9.4|1.3|±.05|3| |**CSLA1EL**|1a|8 to 16|19|625|Vcc/2|5.6|1.3|±.05|3| ## **BOTTOM MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT** |**Catalog**<br>**Listing**|**Mtg.**<br>**Dim.**<br>**Fig.**|**Supply**<br>**Volt.**<br>**(Volts DC)**|**Supply**<br>**Current**<br>**(mA Max.)**|**Sensed**<br>**Current**<br>**(Amps**<br>**Peak)**|**Offset**<br>**Volt.**<br>**(Volts**±**2%)**|**Sensitivity**<br>**mV N***<br>**At 8 VDC**|**Sensitivity**<br>**mV N***<br>**At 8 VDC**|**Offset**<br>**Shift**<br>**(%/**°**C)**|**Response**<br>**Time**<br>**(**µ**Sec.)**| |---|---|---|---|---|---|---|---|---|---| |||||||**Nominal**|±**TOL**||| |**CSLA2CD**|1|6 to 12|20|72|Vcc/2|32.7|3.0|±.02|3| |**CSLA2CE**|1|6 to 12|20|92|Vcc/2|26.1|2.1|±.02|3| |**CSLA2DE**|2|6 to 12|20|92|Vcc/2|25.6|2.2|±.02|3| |**CSLA2CF**|1|6 to 12|20|125|Vcc/2|19.6|1.3|±.02|3| |**CSLA2DG**|2|6 to 12|20|150|Vcc/2|16.2|1.1|±.02|3| |**CSLA2DJ**|2|6 to 12|20|225|Vcc/2|8.7|0.6|±.020|3| |**CSLA2DH**|2|6 to 12|20|235|Vcc/2|9.8|1.1|±.0125|3| |**CSLA2EJ**|1a|6 to 12|20|310|Vcc/2|7.6|0.7|±.0125|3| |**CSLA2DK**|2|6 to 12|20|400|Vcc/2|5.8|0.5|±.0125|3| |**CSLA2EL**|1a|6 to 12|20|550|Vcc/2|4.3|0.4|±.0125|3| |**CSLA2EM**|1a|6 to 12|20|765|Vcc/2|3.1|0.3|±.007|3| |**CSLA2EN**|1a|6 to 12|20|950|Vcc/2|2.3|0.2|±.007|3| NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. PDFINFO* Np a g e =- 0 5 8 number of turns **58** Honeywell Sensing and Control 1-800-537-6945 USA -815-235-6847 International 1-800-737-3360 Canada CS Series ## **Solid State Sensors** Linear Current Sensors ## **SIDE MOUNT WITH 9SS SENSOR, SOURCE OUTPUT** |**Catalog**<br>**Listing**|**Mtg.**<br>**Dim.**<br>**Fig.**|**Supply**<br>**Volt.**<br>**(Volts DC)**|**Supply**<br>**Current**<br>**(mA Max.)**|**Current**<br>**(Amps**<br>**Peak)**|**Sensed**<br>**Offset**<br>**Volt.**<br>**(Volts**±**10%)**|**Sensitivity**|**Sensitivity**|**Sensitivity**|**Sensitivity**| |---|---|---|---|---|---|---|---|---|---| |||||||**mV N***<br>**At 12 VDC**||**Offset**<br>**Shift**<br>**(%/**°**C)**|**Response**<br>**Time**<br>**(**µ**Sec.)**| |||||||**Nominal**|±**TOL**||| |**CSLA1GD**|2a|8 to 16|19|57|Vcc/2|49.6|5.8|±.05|3| |**CSLA1GE**|2a|8 to 16|19|75|Vcc/2|39.4|4.4|±.05|3| |**CSLA1GF**|2a|8 to 16|19|100|Vcc/2|29.7|2.7|±.05|3| ## **SIDE MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT** |**Catalog**<br>**Listing**|**Mtg.**<br>**Dim.**<br>**Fig.**|**Supply**<br>**Volt.**<br>**(Volts DC)**|**Supply**<br>**Current**<br>**(mA Max.)**|**Sensed**<br>**Current**<br>**(Amps**<br>**Peak)**|**Offset**<br>**Volt.**<br>**(Volts**±**2%)**|**Sensitivity**<br>**mV N***<br>**At 8 VDC**|**Sensitivity**<br>**mV N***<br>**At 8 VDC**|**Offset**<br>**Shift**<br>**(%/**°**C)**|**Response**<br>**Time**<br>**(**µ**Sec.)**| |---|---|---|---|---|---|---|---|---|---| |||||||**Nominal**|±**TOL**||| |**CSLA2GD**|2a|6 to 12|20|72|Vcc/2|32.7|3.0|±.02|8| |**CSLA2GE**|2a|6 to 12|20|92|Vcc/2|26.1|2.1|±.02|8| |**CSLA2GF**|2a|6 to 12|20|125|Vcc/2|19.6|1.3|±.02|8| |**CSLA2GG**|2a|6 to 12|20|150|Vcc/2|12.7|0.6|±.02|8| NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. *N = number of turns. ## **MOUNTING DIMENSIONS** (for reference only) **==> picture [35 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Figure 1<br>**----- End of picture text -----**<br> **==> picture [36 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Figure 2<br>**----- End of picture text -----**<br> **==> picture [16 x 2] intentionally omitted <==** **----- Start of picture text -----**<br> PDFINFO p a g e - 0 5 9<br>**----- End of picture text -----**<br> ## **Figure 1a** ## **Figure 2a** **==> picture [9 x 39] intentionally omitted <==** **----- Start of picture text -----**<br> Current<br>**----- End of picture text -----**<br> * Application consideration: The output is clamped at the high end. Clamping voltage may be as low as 9VDC. The output will not exceed the clamping voltage regardless of field strength or supply voltage. Honeywell Sensing and Control ° 1-800-537-6945 USA e+ 1-815-235-6847 International ° 1-800-737-3360 Canada **59**
Updated at April 22, 2026
Honeywell is a globally recognized leader in the design and manufacture of advanced sensing and switching solutions. Renowned for engineering components that deliver enhanced precision and ruggedness, Honeywell provides essential technologies for demanding applications across critical healthcare, aerospace, and industrial equipment. With a comprehensive portfolio built to address both basic and complex design challenges, the company stands at the forefront of reliable electronic component manufacturing. The core of our Honeywell offering is an extensive selection of high-performance sensors and transducers. This includes a robust lineup of pressure sensors and transducers engineered for accurate fluid and gas measurement in challenging environments. Furthermore, we provide a wide array of temperature sensors and specialized temperature sensing NTC thermistors designed for stable thermal management, alongside precision current sensors and load cells that deliver critical feedback for control systems. Beyond advanced sensing technology, Honeywell’s expertise extends to essential circuit protection and electromechanical components. Our selection encompasses power relays, thermal magnetic circuit breakers, and standard terminal blocks, ensuring safe and efficient power distribution. Whether integrating core components or sourcing specialized accessories, design engineers can rely on Honeywell for uncompromising quality and operational excellence.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →