Image not available
Illustrative purposes only
CS10S-24N-0-A
AC/DC Enclosed Power Supply (PSU), Medical, 1 Outputs, 1 kW, 24 VDC, 41.6 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EXCELSYS / ADVANCED ENERGY
- Product type: AC / DC Enclosed Power Supplies
- SVHC: To Be Advised
- Product Range: CS1000 Series
- No. of Outputs: 1Outputs
- Output Power Max: 1kW
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 41.6A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 625.74 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **EXCELSYS CS1000 SERIES** FANLESS, 1U, HIGH EFFICIENCY 1000 W SINGLE OUTPUT POWER SUPPLIES = Advanced Energy’s CS1000, part of our Excelsys product line, is the latest addition to our fanless range of power supplies. The single output CS1000 delivers an incredible convection-cooled 1000 W in an open-frame U-channel form factor, eliminating acoustic noise detrimental to scientific and medical applications, and is ideal for applications sensitive to vibration or where fan cooling is not available. **AT A GLANCE** With an extensive features set including PMBus™, digital control/ communications and analog control, the CS1000 delivers industry leading levels of performance, efficiency, and reliability. ## **Power** ## **CS10S CS10M** **1000 W 1000 W** ## **Output Voltage** ## **PRODUCT HIGHLIGHTS** ## **No Fan Featured** - 1000 W with 100% natural convection - cooling - No base plate needed - No acoustic noise or vibrations ## **Reliability** - High input surge protection — 4 kV line to PE for harsh environments - Reverse energy protection — no blocking diodes required - User selectable (5 V / 12 V) 24 W always ON auxiliary power output - N+1 Redundancy Ready - Can be Paralleled for higher power - Optional Low Leakage (<150 uA) - Safety approved to 5000 m altitude - Programmable start-up state (Default - ON or Default OFF) - > 94% efficiency ## **Flexibility** - Analog and digital management — PMBus™ monitoring and control capability - Mounting options — base/side and DIN-Rail mounting ## **TYPICAL APPLICATIONS** ## **Medical** - Clinical diagnostic equipment, medical lasers, dialysis equipment, radiological imaging, clinical chemistry ## **Industrial** - Test and measurement, industrial machines, automation equipment, printing, telecommunications, audio equipment ## **Hi Rel** - Harsh industrial electronics, radar (navaland ground-based), communications, test and measurement **24 V, 48 V** **Cooling** **No fan featured, convection-cooled** ## **Parameters** **262 x 127 x 39.1 mm** **(10.3 x 5 x 1.5 in)** ## **Certifications** ## **Medical** > **IEC60601-1 3rd edition,** - **2 MOPP** - **Dual fused** ## **Industrial** - **IEC62368-1** - **ISO9001:2015** - **SEMI F471** - Five-year warranty **CS1000 SERIES** ## **MODELS** **==> picture [481 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> CS1000-24 CS1000-48<br>Power (W) 1000 1000<br>Output Voltage (V) 24 48<br>Output Current (A) 41.6 20.8<br>Medical Approval Yes Yes<br>UL/EN60601-1, 3rd Edition<br>Industrial Approval Yes Yes<br>UL/EN62368, 2nd Edition<br>Vnom (V) 24 48<br>Description Convection-cooled U-channel Convection-cooled U-channel<br>Output Adjustment Range (V) 22 to 28 44 to 56<br>Dynamic Vtrim Range (V) 22 to 28 44 to 56<br>Iout Imax (A) 41.6 20.8<br>Remote Sense Yes Yes<br>Power Good Yes Yes<br>AC Good Yes Yes<br>**----- End of picture text -----**<br> ## **ELECTRICAL SPECIFICATIONS** **==> picture [481 x 255] intentionally omitted <==** **----- Start of picture text -----**<br> Input<br>Parameter Conditions/Description Min Nom Max Units<br>AC Operating Input Range Universal input 47 to 440Hz 85 — 264 VAC<br>Nominal Input Voltage Range Universal input 47 to 440Hz 100 — 240 VAC<br>Extended AC Operating Range Maximum for 5 seconds — — 300 VAC<br>Input Current 90 VAC @ 600 W — 8 — A<br>Inrush Current 230 VAC @ 1000 W — — 25 A<br>Power Factor 120 VAC @ 800 W 0.95 0.98 — —<br>Undervoltage Lockout Shutdown 65<br>Voltage Sag 500 ms Ridethrough 65 74 VAC<br>Input Fuses Rating Dual Fused (Line and Neutral) 500VAC — 10 — A<br>Efficiency 230 VAC, 1000 W CS1000-24 — 94 — %<br>230 VAC, 1000 W CS1000-48 — 95 — %<br>Output<br>Power Rating See derating curves — — 1000 W<br>Minimum Load 0 — — A<br>Line Regulation — — 0.25 %<br>Load Regulation — — 0.5 %<br>**----- End of picture text -----**<br> **NOTES** 1. SEMI F47 compliant at input voltages > 180 VAC. Consult Advanced Energy for details. **2 advancedenergy.com** **CS1000 SERIES** ## **ELECTRICAL SPECIFICATIONS (CONTINUED)** **==> picture [482 x 476] intentionally omitted <==** **----- Start of picture text -----**<br> Output (Continued)<br>Parameter Conditions/Description Min Nom Max Units<br>Transient Response For 25% to 75% load change 0.5 A/uS: voltage deviation — — ±6 %<br>Ripple and Noise 20 MHz BW — — 1 %<br>Overvoltage Protection Autorecovery 110 — 140 %<br>Remote Sense Max line drop compensation — — 0.5 VDC<br>Rise Time Monotonic — — 10 ms<br>Turn-On Delay From AC — — 1000 ms<br>From Global Enable — 20 ms<br>Hold-Up Time For nominal output voltages at full load 16 — — ms<br>Overcurrent Protection Hiccup activation 105 120 130 %<br>Short Circuit Protection Yes, Autorecovery — — — —<br>Over Temperature Protection Yes, Autorecovery — — — —<br>Capacitive Load Nominal output voltages at full load — — 10 mF<br>Auxiliary Output<br>Parameter Conditions/Description Min Nom Max Units<br>Nominal Output Voltage Aux voltage option A 11.76 12 12.24 V<br>Aux voltage option B 4.75 5 5.25 V<br>Load Regulation — — ±0.8 %<br>Line Regulation For ±10% change from nominal line — — ±0.25 %<br>Maximum Output Current Aux voltage option A — — 1.96 A<br>Aux voltage option B — — 4.7 A<br>Maximum Output — — 1000 uF<br>Capacitive Load<br>Output Overcurrent Protection Hiccup 110 140 %<br>Short Circuit Protection Yes, autorecovery — — — —<br>Galvanic Isolation<br>Parameter Conditions/Description Min Nom Max Units<br>Reinforced (2 x MOPP); contact Advanced Energy for 4000 — — VAC<br>Input to Output<br>Hi-Pot instructions<br>Input to Case Basic (1 x MOPP) 1500 — — VAC<br>Output to Case Basic (1 x MOPP) 1850 — — VAC<br>Output to Aux Functional 1850 — — VDC<br>**----- End of picture text -----**<br> **advancedenergy.com 3** **CS1000 SERIES** ## **ELECTRICAL SPECIFICATIONS (CONTINUED)** **==> picture [481 x 202] intentionally omitted <==** **----- Start of picture text -----**<br> Reliabilty<br>Parameter Conditions/Description Min Nom Max Units<br>Reliability and MTBF MTBF of > 2,600 kHours, Telecordia SR-332, Issue 4 — 0.38 — Fpmh<br>Warranty 5 years — — — —<br>Environmental<br>Parameter Conditions/Description Min Nom Max Units<br>Operating Temperature Operates to specification below -20°C after 10 min warmup -40 — 85 °C<br>Storage Temperature -40 — 85 °C<br>— — — —<br>Derating See Derating Curves<br>Relative Humidity Non-condensing 5 — 95 %RH<br>Altitude — — 5000 m<br>810G: Method 514.6, Procedure I (General Vibration)<br>Vibration Category 4 Common Carrier (US Highway truck vibration exposure) Fig.514.6C-1<br>Category 4 Composite 2 wheeled trailer vibration exposure, Fig.514.6C-2<br>Category 4 Composite wheeled vehicle vibration exposure, Fig.514.6C-3<br>**----- End of picture text -----**<br> **==> picture [481 x 296] intentionally omitted <==** **----- Start of picture text -----**<br> Leakage Currents<br>Parameter Conditions/Description Nom Units<br>AC Leakage Current Input to Earth Ground — —<br>Normal Condition (High Line) Mains Voltage 264 VAC / 60 Hz 180 µA<br>Single Fault Condition (High Line) Mains Voltage 264 VAC / 60 Hz 350 µA<br>Touch Current<br>Normal Condition Mains Voltage 264 VAC / 60 Hz < 1 µA<br>Single Fault Condition Mains Voltage 264 VAC / 60 Hz 180 µA<br>EMC<br>Parameter Test Type/Conditions Performance Criteria<br>Radiated Emissions2 EN 55011, EN 55022 and FCC, Class B Compliant<br>Conducted Emissions EN 55011, EN 55022 and FCC, Class B Compliant<br>Power Line Harmonics EN 61000-3-2, Class A Compliant<br>Voltage Flicker EN 61000-3-3 Compliant<br>ESD EN 61000-4-2, level 4, 8 kV contact, 15 kV air A<br>Radiated Immunity EN 61000-4-3, level 2, 3 V/m A<br>Electrical Fast Transient EN 61000-4-4, level 4, ±4 kV A<br>Surge Immunity EN 61000-4-5, level 4, 2 kV DM, 4 kV CM A<br>Conducted RF Immunity EN 61000-4-6, level 3, 10 Vemf 150 KHz-80 MHz A<br>Power Frequency Magnetic Field EN 61000-4-8, level 4, 30 A/m A<br>**----- End of picture text -----**<br> **4 advancedenergy.com** **CS1000 SERIES** ## **ELECTRICAL SPECIFICATIONS (CONTINUED)** **==> picture [481 x 243] intentionally omitted <==** **----- Start of picture text -----**<br> Standards and Directives<br>Parameter Conditions/Description<br>EN60601-1 3rd Edition, UL60601-1, CSA601<br>5000 m (16,400 ft) altitude, 100 V to 240 ±10% VAC<br>IEC/EN/UL 60601-1, Edition 3 and All IEC 60601-1(2005), EN60601-1 (2006)<br>National Deviations ANSI/AAMI ES 60601-1 (2005)<br>CAN/CSA C22.2 No. 60601-1 (2008)<br>5,000 m (16,400 ft) altitude, 100 V to 240 VAC ±10%<br>IEC 62368-1 (2014) Edition 2<br>IEC 62368 Edition 2<br>5000 m (16,400 ft) altitude, 100 V to 240 ±10% VAC<br>IEC 60601-1-2 Edition 4 IEC 60601-1-2 (2014)<br>Protection Class Class I<br>WEEE Waste Electrical and Electronic Equipment Directive (WEEE) 2002/96/EC<br>Standards and Directives<br>ROHS EU DIRECTIVE 2011/65/EU RoHS compliancy<br>REACH Compliant<br>**----- End of picture text -----**<br> 2. Consult AE applications for system level compliance. **==> picture [481 x 213] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Data<br>Parameter Description Min<br>Dimensions (L x W x H) Without Lid 262 x 127 x 39.1 mm (10.3 x 5 x 1.5 in)<br>With Lid 262 x 127 x 40.8 mm (10.3 x 5 x 1.6 in)<br>Weight Nominal Weight 1.3 Kg<br>Connectors Description Mating Connectors (if applicable)<br>AC/DC input terminal block TYCO 2-1437667-5 —<br>AC/DC IEC input (Option) IEC 320 Inlet —<br>Main DC output terminal blocks TYCO 2-1437667-5 —<br>System Signal Connector J13 Molex 87831-1620 16-way Locking Molex 51110-1651; Non Locking Molex 51110-1650;<br>Crimp Terminal: Molex p/n 50394<br>—<br>Auxiliary Output Connector J12 Molex 104188-0210 2pin<br>PMBus Address and Auxiliary Molex 87758-1216 12-way Shorting Jumper: Harwin: M22-1900005<br>Select J17 Harwin-M22-2520605<br>Paralleling Header J14 Harwin: M22-2510205; Cvilux: Shorting Jumper: Harwin: M22-1900005<br>CH11022VA00-NH<br>**----- End of picture text -----**<br> **advancedenergy.com 5** **CS1000 SERIES** ## **MECHANICAL DRAWINGS** * Maximum screw penetration from base and sides must not exceed 2mm **6 advancedenergy.com** **CS1000 SERIES** ## **EFFICIENCY AND DERATING CURVES** **advancedenergy.com 7** **CS1000 SERIES** ## **INTERFACE** ## **Input Connectors** Standard (Screw Terminal) Option 1 (IEC Terminal) ## **Output Connectors** **==> picture [102 x 91] intentionally omitted <==** **----- Start of picture text -----**<br> JA<br>Viewed .<br>from rear of the unit<br>**----- End of picture text -----**<br> **==> picture [170 x 91] intentionally omitted <==** **----- Start of picture text -----**<br> / r =<br>Auxiliary Se a Auxiliary<br>4Vo . ' -Vo (GND)<br>**----- End of picture text -----**<br> **Signal Connectors** **8 advancedenergy.com** **CS1000 SERIES** ## **CONFIGURATION** **Example 1:** _CS10M-24N-0-A =_ Medical 24V nominal output voltage, Screw Terminal Input Connector and 12V Aux. **Example 2:** _CS10S-48P-1-B-L_ = Industrial 48V output, with Preset output voltage, IEC input Connector, 5V Aux and Lid **advancedenergy.com 9** ## **ABOUT ADVANCED ENERGY** Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. AE’s power solutions enable customer innovation in complex semiconductor and industrial thin film plasma manufacturing processes, demanding high and low voltage applications, and temperature-critical thermal processes. With deep applications know-how and responsive service and support across the globe, AE builds collaborative partnerships to meet rapid technological developments, propel growth for its customers and power the future of technology. For international contact information, visit advancedenergy.com Specifications are subject to change without notice. Not responsible for errors or omissions. ©2019 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy® and AE® are U.S. trademarks, and CoolX® is a U.S. and European trademark of Advanced Energy Industries, Inc. ENG-LV-CS1000-235-21-09.20
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →