Image not available
Illustrative purposes only
CRF03-1AS
Reed Relay, SPST-NO, 3 VDC, CRF, Surface Mount, 70 ohm, 500 mA
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: STANDEXMEDER
- Product type: Reed Relays
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 5.86 € |
| Current stock | 10+ |
| Lead time | 30 days |
**MEDER electronic**
## **CRF Series**
7 GHz High Frequency Reed Relay for 50 Ω Impedance
## **DESCRIPTION**
## **FEATURES**
- Ceramic / thermoset molded package
- Patent pending
- Smallest in the industry
- No lead frame surface mount design eliminates skewing of leads and coplanarity issues
- Minimum path length for RF
- Up to 7 GHz switching frequencies
-
The MEDER CRF Reed Relay Series is a low-profile device made with a ceramic case that exactly matches the thermal coefficient of expansion of the Reed Switch glass and the reed lead to eliminate any potential packaging stress. Capable of switching up to 7 GHz with <40 ps rise times for digital operations, this leadless 50 Ohm reed relay is the smallest in the industry and switches into the billions of operations.
This Relay has 1 µ V typical thermal offset voltage. Measuring only 8.6 mm x 4.4 mm x 3.4 mm, the leadless design eliminates skewing of leads and coplanarity issues.
- Ability to switch fast pulses with rise times of 40 pico seconds or less
-
- Available with BGA
## **APPLICATIONS**
- Internal magnetic shield standard
- Very low profile
-
- Gold plated leads for high conductivity RF path
- Low thermal offset typical 1 µV
- TCE matching of all internal components
-
- Insulation resistance typical 1014 ohms
-
- 3 Volt option available
-
- Test and measurement
- Medical Equipment
- Telecommunications
-
- High frequency applications
-
## **DIMENSIONS (Non-BGA)**
*All dimensions in mm (inch)
**PIN OUT** (Top View)
## **PCB LAYOUT**
## **PAD LAYOUT**
(Bottom View)
**==> picture [126 x 79] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.60<br>[0.0472] _—_ 1.20 — [ØØ 0.0031]0.95 [0.1417] — [0.0197]0.50<br>[0.0276]0.70 10x R0.475[0.187] {|—<br>1.20<br>[0.0472]<br>0.95 3.125<br>[0.0374] [0.123]<br>a [0.378]9.60 e |<br>4.40<br>[0.1732] 1.45 [0.0571]<br>2.20 [0.0866] 1.475 [0.0581]<br>0.925 [0.0364]<br>**----- End of picture text -----**<br>
www.meder.com
**134**
**CRF Series**
**MEDER electronic**
7 GHz High Frequency Reed Relay for 50 Ω Impedance
## **DIMENSIONS (with BGA)**
*All dimensions in mm (inch)
**==> picture [133 x 36] intentionally omitted <==**
**PIN OUT** (Top View)
## **PAD / PCB LAYOUT**
(Bottom View)
## **POST REFLOW**
**==> picture [72 x 37] intentionally omitted <==**
**==> picture [67 x 31] intentionally omitted <==**
**==> picture [32 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
Höhe: max.<br>**----- End of picture text -----**<br>
## **ORDER INFORMATION**
## Part Number Example
CRF05 - 1AS
**05** is the nominal voltage **1A** is the contact form **S** is the solder ball option
|**ATION**||||
|---|---|---|---|
|Series|Nominal<br>Voltage|Contact<br>Form|Option|
|CRF|05-|1A|X|
|Options|||S*|
|* Solder Ball Option (non-BGA part number is CRF05-1A)||||
## **COIL DATA**
**==> picture [382 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
Contact Switch Coil Coil Pull-In Drop-Out Nominal<br>Form Model Voltage Resistance Voltage Voltage coil Power<br>VDC Ω VDC VDC mW<br>All Data<br>at 20 °C * Nom. Max. Min. Typ. Max. Max. Min. Typ.<br>1A 80 5 7.5 135 150 165 3.75 0.75 167<br>1A 80 3 5 63 70 77 2.25 0.45 129<br>* the pull-in / drop-out voltages and coil resistance will change at the rate 0,4% per [o] C<br>**----- End of picture text -----**<br>
www.meder.com
**135**
**CRF Series**
**MEDER electronic**
7 GHz High Frequency Reed Relay for 50 Ω Impedance
## **RELAY DATA**
**==> picture [334 x 463] intentionally omitted <==**
**----- Start of picture text -----**<br>
Switch Model → Contact 80<br>All Data at 20° C<br>Contact Form → Form A<br>Contact Ratings Conditions Min. Typ. Max. Units<br>Contact Ratings Any DC combination of V & A not to exceed their individual max.‘s. 10 W<br>Switching Voltage DC or peak AC 170 V<br>Switching Current DC or peak AC 0.5 A<br>Carry Current DC or peak AC 0.5 A<br>Bulk Resistance Through all plated material on 200 350 mΩ<br>substrate<br>Static Contact Resistance w/ 0.5 V & 50 mA 75 100 mΩ<br>Dynamic Contact Resistance Measured w/ 0.5 V & 50mA 100 150 mΩ<br>Insulation Resistance Across Contact 10 [10] 10 [12]<br>Ω<br>(100 Volts applied) Contact to coil and shield 10 [13] 10 [14]<br>Across Contact 210<br>Breakdown Voltage Coil to contact 1500 VDC<br>Operate Time incl. Bounce Measured w/ nominal voltage 0.1 ms<br>Release Time No coil suppression 0.02 ms<br>Across Contact 0.1<br>Capacitance (@ 10 kHz) Contact to coil and shield 0.7 pF<br>Life Expectancies<br>10 [6]<br>Switching 5 V - 10mA DC <10 pF stray cap. 1000<br>Cycles<br>For other load requirements, see the life test section on P. 120.<br>Environmental Data<br>Shock Resistance 1/2 Sine wave duration for 11 ms 50 g<br>Vibration Resistance From 10 - 2000 Hz 10 g<br>Ambient Temperature 10 [o] C/ minute max. allowable -40 125 oC<br>Storage Temperature 10 [o] C/ minute max. allowable -55 125 oC<br>Soldering Temperature 5 sec. dwell 260 oC<br>Material of Case Themoset / Ceramic<br>Material of pads Au plated<br>**----- End of picture text -----**<br>
www.meder.com
**136**
**MEDER electronic**
**CRF Series**
7 GHz High Frequency Reed Relay for 50 Ω Impedance
## **Insertion Loss:**
_Insertion loss tested to 7 GHz for the CRF Reed Relay. Horizontal full scale: 7.0 GHz. Vertical scale: 10 dB/div referenced from the 0 mark._
## **Copper Wire Insertion Loss:**
_Insertion loss tested to 7 GHz for the CRF Reed Relay but with the internal Reed Switch replaced with a bare copper wire. Horizontal full scale: 7.0 GHz. Vertical scale: 10 dB/div referenced from the 0 mark._
## **VSWR:**
_Voltage Standing Wave Ratio (VSWR) tested to 6.5 GHz for the CRF Reed Relays. Horizontal full scale: 6.5 GHz. Vertical scale: 1.0/div referenced from the bottom line 1.0 mark._
## **Isolation:**
_Isolation tested to 7 GHz for the CRF Reed Relay. Horizontal full scale: 7.0 GHz. Vertical scale: 10 dB/div referenced from the 0 mark._
www.meder.com
**137**
**MEDER electronic**
## **CRF Series**
## 7 GHz High Frequency Reed Relay for 50 Ω Impedance
## **Return Loss:**
## **Characteristic Impedance:**
_Return loss tested to 6.5 GHz for the CRF Reed Relay. Horizontal full scale: 6.5 GHz. Vertical scale: 10 dB/div referenced from the 0 mark._
_Represents the characteristic impedance going through the CRF Reed Relay. Waves 1 through 5 depict calibration points. Horizontal full scale: 750 ps. Vertical scale: 150 mUnit/div referenced from the 0 unit mark. The vertical scale measures the reflection coefficient._
## _1 - Short Before Relay_
## **Smith Chart:**
- _2 - Open Contacts_
- _3 - Close Contacts_
- _4 - Closed Contacts - Shorted_
- _5 - Closed Contacts - 50 Ohm_
/\
_Shows a Smith Chart plotted for frequencies to 4 GHz. The second dotted circle starting from the right is the 50 Ohm impedance point._
www.meder.com
**138**
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →