Image not available
Illustrative purposes only
CPS255-M
AC/DC Open Frame Power Supply (PSU), Medical, 1 Output, 250W @ 300LFM, 155 W, 90V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ARTESYN / ADVANCED ENERGY
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):155W; Power Rating (Forced Cooling):250W @ 300LFM; Input Voltage VAC:90V AC to 264V AC; Power Supply Output Type:Adjustable, Fixed;
- SVHC: To Be Advised
- Product Range: CPS250-M Series
- No. of Outputs: 1 Output
- Output Power Max: 250W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 6.45A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): 250W @ 300LFM
- Power Rating (Convection Cooling): 155W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 84.17 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **ARTESYN CPS250-M SERIES** 250 W AC-DC Power Supplies Advanced Energy's Artesyn CPS250-M series of single output open-frame AC-DC power supplies are offered in 12 V, 24 V, or 48 V outputs with +10% trim range. Each power supply comes with a 12 V fan output. All models feature ITE and medical safety approvals and accept a universal input of 90 to 264 VAC. Depending on operating conditions, its 2'' x 4'' x 1.29'' compact and high density design delivers up to 155 W of output power with free air convection cooling and up to 250 W with 300 LFM of forced air. These power supplies are ideal for light industrial systems as well as for medical applications. ## **SPECIAL FEATURES** ## **SAFETY** - EN 62368-1/60601-1 - Designed for forced air and natural convection cooling - UL/CSA 62368-1/60601-1 - Medical and ITE safety approvals, 2x MOPP - CSA - CE LVD Mark - Dual fused - CCC - Type BF ready - UKCA Mark - Active Power Factor Correction, 61000-3-2 compliant - ** CPS250-M tested according to the medical standard IEC 60601-1-2 4th Edition. - Built-in Class B EMI filter ## **AT A GLANCE** ## **Total Power:** **250 W** ## **Input Voltage:** **90 to 264 VAC** **# of Outputs:** **Single** - Less than 1U high - LPX100 enclosure kit available - < 500 mW no-load power consumption - Compact size: 2" x 4" x 1.3" - For use in Class I or Class II applications - Three-year warranty (consult factory for extended terms) ©2022 Advanced Energy Industries, Inc. **CPS250-M SERIES** ## **ELECTRICAL SPECIFICATIONS** **==> picture [479 x 292] intentionally omitted <==** **----- Start of picture text -----**<br> Input<br>Input voltage ra nge 90 to 264 VAC<br>Frequency 47 to 63 Hz (360 to 440 Hz with higher leakage)<br>Inrush current 70 Apk, < 1 ms, cold start<br>Efficiency 93% typical<br>Leakage current Specified for medical approvals<br>No load power < 500 mW<br>Output<br>Maximum power 250 W, forced-air cooling<br>155 W, free-air natural convection<br>Adjustment range -0%/+10%<br>Holdup time 10 ms @ 225 W<br>Fan output 12 V @ 500 mA<br>Standby output 5 V @ 100 mA (For CPS253-M1 only)<br>Control and Protection<br>Remote On/Off For CPS253-M1 only<br>DC OK For CPS253-M1 only<br>Overvoltage protection Latching/AC Recycle required to restart PSU<br>Overcurrent protection Auto-recovery<br>Short circuit protection Auto-recovery (impedance <50 mOhm)<br>Overtemperature protection Auto-recovery with hysteresis<br>**----- End of picture text -----**<br> ## **ENVIRONMENTAL SPECIFICATIONS** **==> picture [480 x 72] intentionally omitted <==** **----- Start of picture text -----**<br> Operating temperature -20 °C to +70 °C (derate at 50 °C), startup at -40 °C<br>Storage temperature -40 °C to +85 °C<br>Operating humidity 5% to 90% (non-condensing)<br>Non-operating humidity 5% to 95% (non-condensing)<br>Maximum altitude 5000 m (3000 m for medical), derating may apply<br>**----- End of picture text -----**<br> **2 advancedenergy.com** **CPS250-M SERIES** ## **OTHER SPECIFICATIONS** **==> picture [480 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> Isolation 4000 VAC (input to output)<br>1500 VAC (input to PE, output to PE)<br>Line harmonics 61000-3-2, Class A<br>Conducted EMI* Level B, CISPR 22 and FCC Part 15<br>Radiated EMI* Level B, CISPR 22 and FCC Part 15<br>Surge immunity Level 3, 61000-4-5, Criterion A<br>Medical EMC 60601-1-2, Edition 4 (cover may be required for some tests)<br>MTBF > 2.2 MHrs, 25 °C, 155 W Natural Convection, 115 VAC<br>(Telcordia, Issue 3, Method 1 Case 3) > 5.1 MHrs, 25 °C, 250 W Forced Air, 115 VAC<br>**----- End of picture text -----**<br> *Applies to Class I input with ground tabs tied to a common ground plane and connected to system ground. Consult Technical Reference Notes for details. ## **PIN ASSIGNMENTS** **==> picture [479 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> Connector Pin Number Designation Mating Conectors<br>J5 (AC input) 1 AC Input L1/Line Molex 09-50-8031 housing with 45570-3000 crimp or<br>3 AC Input L2/Neutral equivalent. AWG 20-18 wires.<br>Mounting Holes PE<br>J0 (DC output) 1 Main Output Return Molex 09-50-8061 housing with 45570-3000 crimp or<br>2 Main Output Return equivalent. AWG 20-18 wires.<br>3 Main Output Return<br>4 Main Output<br>5 Main Output<br>6 Main Output<br>BusBar (DC output) 1 Main Output Ring terminal: Tyco 35148 or KST RV3-4 or equivalent.<br>Applies to 12 V variant only 2 Main Output Return<br>J2 (Fan supply) 1 Fan Return Cvilux: CI0102S0000 housing; CI01T01MPP0 crimp<br>2 Fan Voltage Landwin: 2001S0200 housing; 2005T011V crimp<br>AWG # 30-24<br>J403 1 5 Vdc Standby Molex 504193-0500 with 504185-1000 crimp or<br>Applies to CPS253-M1 only 2 Standby Return equivalent. AWG 30-26 wires.<br>3 Remote Inhibit<br>4 DC OK<br>5 VFB (Feedback loop pin)<br>**----- End of picture text -----**<br> **advancedenergy.com 3** **CPS250-M SERIES** ## **MECHANICAL DRAWINGS - 12 V VARIANT** **==> picture [93 x 81] intentionally omitted <==** **==> picture [59 x 44] intentionally omitted <==** **==> picture [60 x 58] intentionally omitted <==** **4 advancedenergy.com** **CPS250-M SERIES** ## **MECHANICAL DRAWINGS - 24 V AND 48 V VARIANTS** **==> picture [93 x 78] intentionally omitted <==** **==> picture [56 x 43] intentionally omitted <==** **==> picture [58 x 56] intentionally omitted <==** **advancedenergy.com 5** **CPS250-M SERIES** ## **MECHANICAL DRAWINGS - CPS253-M1** **==> picture [408 x 357] intentionally omitted <==** **----- Start of picture text -----**<br> 32.77MAX Vo(+) 50.8 ASSY-J0<br>2.5MAX (2X)43.8 (2X)3.5<br>J2-PIN 1<br>Q501<br>SEE DETAIL A<br>J2<br>WARNING LABEL J 403<br>C12 SEE DETAIL B<br>T501<br>BARCODE<br>L2<br>M ODEL LABEL J5 -PIN 1 INPUT J5<br>PREFERRED EARTH<br>J403 - PIN1<br>Q 501<br>DETAIL A<br>(4X) 4<br>(2X)3.5<br>101.6<br>(2X)94.6<br>**----- End of picture text -----**<br> **==> picture [29 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> DETAIL B<br>**----- End of picture text -----**<br> ## Notes: OCP can not be adjusted on the fly. Default setting is for 250 W Forced Air. Unit should be turned off before trimpot adjustment. OCP does not vary linearly with the trimpot adjustment. It is either Full clockwise (250 W) or Full counter clockwise (155 W). Thermal Hot Spot Reference - Do not exceed indicated temperature limits to ensure operation is within the conponent thermal derating limits. Measure the component temperatures using K type thermocouples. Recommended Mounting Screw - M3.0 (4X) Pan head screw with teeth washer, 6 mm length, 6~8 Kgf-cm Torque. Unit weight 200 g max **==> picture [231 x 83] intentionally omitted <==** **----- Start of picture text -----**<br> Thermal Hot Spot Reference<br>Component Temperature Limit<br>L2 135 °C<br>T501 145 °C<br>Q501 120 °C<br>C12 95 °C<br>**----- End of picture text -----**<br> **6 advancedenergy.com** **CPS250-M SERIES** ## **OUTPUT POWER DERATING** **==> picture [478 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> Output Power Derating Output Power VS. Input Line<br>300 275<br>250 250<br>225<br>200<br>200<br>150 175<br>100 150<br>FORCED AIR 125 FORCED AIR<br>50<br>NATURAL CONVECTION 100 NATURAL CONVECTION<br>0 75<br>0 10 20 30 40 50 60 70 80 90 110 130 150 170 190 210 230 250 270<br>Ambient Temperature [°C] AC Input Line [Vac]<br>Output Power [Watts] Output Power [Watts]<br>**----- End of picture text -----**<br> Figure 1. Output Power vs. Ambient Temperature at Natural Convection and Forced Air Cooling [300 LFM]. Figure 2. Output Power vs. Input Line at Natural Convection and Forced Air Cooling [300 LFM]. ## **EFFICIENCY CURVES** **==> picture [229 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> CPS253‐M (12V) Efficiency Curve<br>96%<br>95%<br>94%<br>93%<br>92%<br>91%<br>90%<br>89%<br>88% 115 Vac<br>230 Vac<br>87%<br>86%<br>0 0.2 0.4 0.6 0.8 1<br>% of Rated Output Load<br>Efficiency<br>**----- End of picture text -----**<br> Figure 3. Typical Efficiency for 12 V Output **==> picture [230 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> CPS258‐M (48V) Efficiency Curve<br>96%<br>95%<br>94%<br>93%<br>92%<br>91%<br>90%<br>89%<br>88% 115 Vac<br>230 Vac<br>87%<br>86%<br>0 0.2 0.4 0.6 0.8 1<br>% of Rated Output Load<br>Efficiency<br>**----- End of picture text -----**<br> Figure 5. Typical Efficiency for 48 V Output **==> picture [231 x 335] intentionally omitted <==** **----- Start of picture text -----**<br> CPS255‐M (24V) Efficiency Curve<br>96%<br>95%<br>94%<br>93%<br>92%<br>91%<br>90%<br>89%<br>88% 115 Vac<br>230 Vac<br>87%<br>86%<br>0 0.2 0.4 0.6 0.8 1<br>% of Rated Output Load<br>Figure 4. Typical Efficiency for 24 V Output<br>Natural Convection Estimated Service Life vs Component Temp<br>150<br>100<br>Estimated Life<br>50<br>0<br>110 100 90 80 70 60 50<br>C12 Temperature [ °C]<br>Efficiency<br>Lifetime (KHrs)<br>**----- End of picture text -----**<br> Figure 6. Estimated Product Useful Life Based on C12 (bulk capacitor) Case Temperature **advancedenergy.com 7** **CPS250-M SERIES** ## **ORDERING INFORMATION** **==> picture [479 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> Model Output Minimum Max. Continuous Peak Load 1 Max. Continuous 2 Regulation3 Ripple (p-p)4<br>number voltage load Load (Free Air) (Free Air) Load (Forced Air)<br>CPS253-M 12 V 0 A 12.92 A 15.5 A 20.83 A ±2% 120 mV<br>CPS253-M1 12 V 0 A 12.92 A 15.5 A 20.83 A ± 2% 120 mV<br>CPS255-M 24 V 0 A 6.45 A 7.74 A 10.42 A ±2% 240 mV<br>CPS258-M 48 V 0 A 3.23 A 3.88 A 5.21 A ± 2% 480 mV<br>**----- End of picture text -----**<br> - 1 Peak Load current not to exceed 30 seconds with maximum 10% duty cycle. 2 Requires at least 300 LFM of airflow. 3 At 25 °C including factory setpoint, Line voltage and Load current variations. 4 Peak to peak ripple measured at the output terminals with 10 µF tantalum capacitor in parallel with 0.1 µF ceramic capacitor across the output & at 25 °C and output load ≥ 6 W. ## **ACCESSORIES AND CONNECTOR KITS** **==> picture [479 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> Part Number Description<br>70-841-032 CPS255-M (24 V) and CPS258-M (48 V): Complete mating connector kit for Input (J5); Output (J0) and 12 V fan supply (J2)<br>70-841-033 CPS253-M (12 V): Complete mating connector kit for Input (J5); DC busbar ring lugs and 12 V fan supply (J2)<br>CPS253-M1 (12 V + M1 option): Complete mating connector kit for Input (J5); DC busbar ring lugs; 12 V fan supply (J2) and<br>70-841-034<br>“-M1” optional features (J403)<br>**----- End of picture text -----**<br> **8 advancedenergy.com** **==> picture [596 x 270] intentionally omitted <==** ## **ABOUT ADVANCED ENERGY** Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. For international contact information, visit advancedenergy.com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2022 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc. ENG-CPS250-M-235-01 4.20
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →