Image not available
Illustrative purposes only
CPP11-52-4.00A-OB-V
MAGNETIC HYDRAULIC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA / PARTNER STOCK
- Product type: Magnetic Hydraulic Circuit Breakers
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 9 |
| Price | 31.15 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Snapak® Series** Magnetic Circuit Protectors |_Introduction_|**•** **_55_**| |---|---| |_Handles_|**•** **_56_**| |_Configurations_|**•** **_61_**| |_Operating Characteristics_|**•** **_63_**| |_Delay Curves_|**•** **_64_**| |_Specifications_|**•** **_65_**| |_Hardware_|**•** **_66_**| |_Decision Tables_|**•** **_67_**| ## AIRPAX: | **T/R/PP/PR/CR/CPP/CPR Series** Hydraulic Magnetic Circuit Protectors (SNAPAK®) ## **INTRODUCTION** The Airpax™ SNAPAK® series is a snap-acting hydraulicmagnetic circuit protector that combines power switching and accurate, reliable circuit protection in one aesthetically pleasing package. The SNAPAK® combines the functions of three separate components: power switch, fuse and fuse holder. To the OEM, this means that only one item has to be mounted instead of three. Less assembly is required, inventory is cut by twothirds and greater panel density is obtainable with less clutter. In addition, the SNAPAK® can be operated at either DC or 50/60Hz, eliminating the need to specify, order and stock separate units. 400Hz units are also available. Since the SNAPAK® is snap-acting, it assures immediate opening and closing of the contacts. Its design also prevents operator “teasing” of the contacts and minimizes arcing. SNAPAK® circuit protectors are UL Recognized as supplementary protectors per UL STD. 1077, CSA Certified as supplementary protectors per CSA STD. C22.2 No. 235, TUV Approved as circuit breakers for equipment per STD. EN 60934, CCC Approved (customer must request product be manufactured in China) and CE Compliant. In addition, most versions are certified by UL to meet spacing requirements of IEC 950 for basic and functional insulation for front panel mounting. To enhance front-panel aesthetics, SNAPAK® is offered with paddle and rocker handles in six attractive colors and push-pull and push-to-reset actuators. Also offered is a variety of optional mounting hardware. The push-pull version is supplied with a black button with a white indicating band. Orientation of the button when marked with an amperage notation must be specified when using the fourth decision table. Push-to-reset is supplied with a contrasting color indicating shaft. In addition, SNAPAK® is offered in SPST and DPST configurations. The single pole satisfies most applications. The two-pole version is often used for extra safety in products that utilize high voltage or where current sensing and breaking of both sides of the line is required. Quick connect terminals are standard, UNC 8-32 or M4 screw terminals are available as additional termination options. Consult factory for details and exceptions. Typical applications include office appliances, electronic data processing, medical equipment, business machines, vending and amusement machines. Push-pull versions are particularly well suited for medical instrumentation, automotive production transfer lines and other applications where accidental turn off is unacceptable. For those applications which do not require circuit protection, SNAPAK® is offered in a power-switch-only configuration. **55** _SNAPAK_ _**®** Series - Introduction_ http://airpax.sensata.com Mounting Details with Locking Ring ## **TOGGLE ACTUATORS** **==> picture [136 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> .500 ± .010<br>.000<br>.355<br>[12.70 ± ].025<br>[9.02] .000<br>.125<br>[3.18]<br>**----- End of picture text -----**<br> ## without Locking Ring The SNAPAK® is available with paddle handles in six attractive colors. Engineered for safe, sure operation, the paddle handles may be specified in blue, white, red, green, yellow or black. **==> picture [166 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> .500 ± .010<br>.000<br>.222 ± 0.002<br>[12.70 ± ].025<br>[5.64 ± 0.05] .000<br>**----- End of picture text -----**<br> PANEL CUTOUT SHOWN ABOVE MAY BE MADE WITH GREENLEE RADIO CHASSIS PUNCH #733 x 1/2” DIA. Note: Mounting Tolerance ± .005 [.13] unless noted angles: ±5°. Dimensions in Brackets [ ] are millimeters. ## Single Pole, Toggle **==> picture [495 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> .680 ± 0.010<br>.125 ± 0.010<br>[17.27 ± 0.25] 1/2 - 32 THD<br>[3.17 ± 0.25]<br>2 15º<br>ON<br>1.125 ± 0.030 Paddle Handle 1.375 ± 0.010<br>.031<br>[28.58 ± 0.76] [34.93 ± 0.25]<br>[0.79] 1 LINE FLAT 15º OFF<br>0.500 ± 0.030<br>.250 .375 ± 0.010<br>[12.70 ± 0.76]<br>[6.35] [9.53 ± 0.25] 1.715 ± 0.030<br>[43.56 ± 0.76] .468 ± 0.010<br>[11.89 ± 0.25]<br>**----- End of picture text -----**<br> Two Pole, Toggle **==> picture [519 x 165] intentionally omitted <==** **----- Start of picture text -----**<br> 1.304 ± 0.010<br>.625 ± 0.010<br>.125 ± 0.010<br>[33.12 ± 0.25]<br>[15.88 ± 0.25] 1/2 - 32 THD<br>[3.17 ± 0.25]<br>POLE 1 POLE 2<br>2 4 15º<br>ON<br>1.125 ± 0.030 1.375 ± 0.010<br>.031 Paddle Handle<br>[28.58 ± 0.76] [34.93 ± 0.25]<br>[0.79] 1 LINE LINE 3 FLAT 15º OFF<br>0.500 ± 0.030<br>.250 .375 ± 0.010<br>[12.70 ± 0.76]<br>[6.35] [9.53 ± 0.25] 1.715 ± 0.030<br>[43.56 ± 0.76] .468 ± 0.010<br>[11.89 ± 0.25]<br>**----- End of picture text -----**<br> _SNAPAK_ _**®** Series - Handles_ **56** **==> picture [612 x 61] intentionally omitted <==** ## **ROCKER HANDLES WITH ILLUMINATION** SNAPAKs are offered in single and two pole rocker styles in a choice of black, white or gray body colors. Handle color in non-illuminated types may be black, red, white or orange. Neon or light emitting diode (LED) illumination may be specified with a variety of options. SNAPAK[®] circuit protectors with a second pole are available in paddle handle, push-pull, push-to-reset and rocker handle versions. **==> picture [134 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting Detail<br>.710 ± .010<br>.000<br>[18.03 ± ].025<br>.000<br>DIM. A<br>(SEE TABLE)<br>**----- End of picture text -----**<br> Rocker, Single Pole **==> picture [233 x 136] intentionally omitted <==** **----- Start of picture text -----**<br> 0.030 ± 0.325<br>0.125 ± 0.010<br>[8.26 ± 0.76]<br>[3.18 ± 0.25]<br>1.375 ± 0.010<br>1.125 ± 0.030<br>[34.93 ± 0.25]<br>[28.58 ± 0.76]<br>0.375 ± 0.010<br>[9.53 ± 0.25]<br>1.840 ± 0.030 0.093 ± 0.010<br>[46.74 ± 0.76] [2.36 ± 0.25]<br>**----- End of picture text -----**<br> **==> picture [286 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> 0.680 ± 0.010 0.770 ± 0.010<br>[17.27 ± 0.25] [19.56 ± 0.25]<br>2<br>1.560 ± 0.010 ON 0.972 ± 0.010<br>0.031 [39.62 ± 0.25] OFF [24.69 ± 0.25]<br>[0.79] 1 LINE<br>0.250<br>[6.35]<br>0.400 ± 0.010<br>[10.16 ± 0.25]<br>**----- End of picture text -----**<br> ## **HANDLE GUARDS** The SNAPAK[®] circuit protector is available with an optional handle guard as an integrated part of the snap-in mounting design. Available for rocker actuators, the guard helps in providing protection from accidental “turn-off.” Please refer to the SNAPAK[®] Part Number Decision Tables; fourth decision. Handle Guards, Single Pole **==> picture [71 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> 0.305 ± 0.010<br>[7.75 ± 0.25]<br>1.047 ± 0.010<br>[26.60 ± 0.25]<br>**----- End of picture text -----**<br> **==> picture [41 x 79] intentionally omitted <==** **==> picture [40 x 76] intentionally omitted <==** Handle Guards, Two Pole **==> picture [71 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> 0.305 ± 0.010<br>[7.75 ± 0.25]<br>1.047 ± 0.010<br>[26.60 ± 0.25]<br>**----- End of picture text -----**<br> **==> picture [41 x 79] intentionally omitted <==** **==> picture [53 x 91] intentionally omitted <==** _SNAPAK_ _**®** Series - Handles_ http://airpax.sensata.com **57** **==> picture [612 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> FRONT SNAP-IN MOUNT (STD) Mounting Detail<br>1.329 ± .010<br>.000<br>Panel Thickness 0.125 0.093 0.062<br>[33.76 ± ].025<br>[3.18] [2.36] [1.57] .000<br>Dimension “A” 1.460 1.420 1.385<br>[37.08] [36.07] [35.18] DIM. A<br>(SEE TABLE)<br>Note: Tolerance for Mtg. ± .005 (.13)<br>SNAPAK® (T/R/PP/PR CR/CPP/CPR)<br>**----- End of picture text -----**<br> ## Rocker, Two Pole **==> picture [533 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> 1.304 ± 0.010<br>0.125 ± 0.010 0.030 ± 0.325 [33.12 ± 0.25] 1.394 ± 0.010<br>[8.26 ± 0.76]<br>[3.18 ± 0.25] POLE 1 POLE 2 [35.41 ± 0.25]<br>2 4<br>1.375 ± 0.010 ON<br>1.125 ± 0.030 1.560 ± 0.010 0.972 ± 0.010<br>[34.93 ± 0.25]<br>[28.58 ± 0.76] 0.031 [39.62 ± 0.25] OFF [24.69 ± 0.25]<br>[0.79] 1 LINE LINE 3<br>0.375 ± 0.010<br>0.250<br>[9.53 ± 0.25]<br>1.840 ± 0.030 0.093 ± 0.010 [6.35]<br>0.400 ± 0.010<br>[46.74 ± 0.76] [2.36 ± 0.25] 0.625 ± 0.010<br>[10.16 ± 0.25]<br>[15.88 ± 0.25]<br>**----- End of picture text -----**<br> Illuminated Handle Single Pole **==> picture [38 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Two Pole<br>**----- End of picture text -----**<br> **==> picture [395 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> 2 LOAD 2 4 LOAD<br>1 LINE LINE 1 LINE LINE 3 LINE<br>RED (+), BLACK(–) RED (+), BLACK (-)<br>7.00 ± 0.50<br>7.00 ± 0.50<br>[177.8 ± 12.7]<br>[177.8 ± 12.7]<br>**----- End of picture text -----**<br> Note: Tolerance ± .005 [.13] unless noted angles: ±5°. Dimensions in Brackets [ ] are millimeters. _SNAPAK_ _**®** Series - Handles_ **58** **==> picture [612 x 61] intentionally omitted <==** ## **PUSH-PULL, PUSH-TO-RESET ACTUATOR** SNAPAK[®] may also be ordered with Push-Pull, or Pushto-Reset actuator buttons. As an option, the button can be embossed with the current rating (Push-Pull option only). Push-Pull, Single Pole Push-Pull, Two Pole **==> picture [287 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> 1.960 ± 0.030 .400 ± 0.010<br>[49.78 ± 0.76] [10.16 ± 0.25]<br>FLAT<br>Push-Pull Actuation<br>.375 ± 0.010 0.500 ± 0.030<br>[9.53 ± 0.25] 3/8 - 32 THD [12.70 ± 0.76] [OFF (SHOWN)]<br>WHITE BAND VISIBLE 0.250 ± 0.030<br>ON<br>IN OFF POSITION ONLY [6.35 ± 0.76]<br>**----- End of picture text -----**<br> **==> picture [275 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> 1.960 ± 0.030 .400 ± 0.010<br>[49.78 ± 0.76] [10.16 ± 0.25]<br>FLAT<br>Push-Pull Actuation<br>.375 ± 0.010 0.500 ± 0.030<br>[9.53 ± 0.25] 3/8 - 32 THD [12.70 ± 0.76] [OFF (SHOWN)]<br>WHITE BAND VISIBLE 0.250 ± 0.030<br>ON<br>IN OFF POSITION ONLY [6.35 ± 0.76]<br>**----- End of picture text -----**<br> **==> picture [477 x 367] intentionally omitted <==** **----- Start of picture text -----**<br> 1.125 ± 0.030<br>1.125 ± 0.030 .125 ± 0.010<br>[28.58 ± 0.76]<br>.125 ± 0.010 [28.58 ± 0.76] [3.18 ± 0.25]<br>[3.18 ± 0.25]<br>POLE 2 .250<br>.625 ± 0.010<br>[6.35]<br>.250 [15.88 ± 0.25]<br>POLE 1<br>.031 [6.35]<br>[.79]<br>.031<br>[.79]<br>1.375 ± 0.010<br>1.375 ± 0.010<br>[34.93 ± 0.25]<br>[34.93 ± 0.25]<br>.680 ± 0.010<br>1.304 ± 0.010<br>[17.27 ± 0.25]<br>[33.12 ± 0.25]<br>Mounting Detail Push-to-Reset Actuation<br>(Single Pole and Two Pole) (Single and Two Pole)<br>.162 ± 0.002<br>[4.11 ± 0.05] .375 ± .010.000<br>[9.53 ± ].025 0.76 ± 0.030<br>.000 OFF<br>[6.35 ± 0.25]<br>FLUSH ± 0.030<br>ON<br>Note: Tolerance ± .005 [.13] unless noted angles: ±5°. Dimensions in Brackets [ ] are millimeters. [FLUSH ± 0.25]<br>4 LINE 3<br>2 1 LINE<br>2 1 LINE<br>**----- End of picture text -----**<br> Note: Tolerance ± .005 [.13] unless noted angles: ±5°. Dimensions in Brackets [ ] are millimeters. _SNAPAK_ _**®** Series - Handles_ http://airpax.sensata.com **59** ## **SCREW TERMINALS** Available as straight screw terminals with UNC 8-32 and Metric M4 screw types, bus-type connect (flat) or upturned lugs (tabs), with UL, CSA and TÜV approvals available. Screw terminals are available for all handle options (rocker, toggle, push-pull, push-to-reset). Single pole only, series only, non-auxiliary switch configurations. **==> picture [85 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> Toggle<br>DIM. “A”<br>(SEE TABLE)<br>**----- End of picture text -----**<br> Push Button |**DIMENSION “A”**|**DIMENSION “A”**|**DIMENSION “A”**| |---|---|---| |**Handle Style**<br>**Screw Terminal**<br>**“A” Dimension**||| |Toggle<br>|Straight<br>|1.773 [45.03]<br>| |Push Button|Straight|2.180 [55.37]| |Rocker|Straight|2.058 [52.27]| **==> picture [41 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> DIM. “A”<br>(SEE TABLE)<br>**----- End of picture text -----**<br> Rocker **==> picture [67 x 22] intentionally omitted <==** **----- Start of picture text -----**<br> DIM. “A”<br>(SEE TABLE)<br>**----- End of picture text -----**<br> **==> picture [157 x 117] intentionally omitted <==** **----- Start of picture text -----**<br> Straight<br>0.597<br>[15.16]<br>1.067 0.374<br>[27.11] [9.50]<br>**----- End of picture text -----**<br> _SNAPAK_ _**®** Series - Handles_ **60** **==> picture [612 x 61] intentionally omitted <==** ## **CONFIGURATIONS** ## **Series Trip** The most popular configuration for magnetic protectors is the series trip where the sensing coil and the contacts are in series with the load being protected. In addition to providing conventional overcurrent protection, it is simultaneously used as an on-off switch. **==> picture [221 x 102] intentionally omitted <==** **----- Start of picture text -----**<br> Series Trip Two<br>Single Pole Pole<br>LOAD<br>2 LOAD 2 4<br>1 LINE LINE 1 LINE LINE 3<br>LINE<br>**----- End of picture text -----**<br> ## **Shunt Trip** The shunt trip is designed for controlling two separate loads with one assembly. The control is established by providing overload protection for the critical load. When the current through this load becomes excessive and reaches the trip point, the protector will open and remove power from both loads simultaneously. The current rating of both loads must not exceed the maximum contact rating. **==> picture [46 x 22] intentionally omitted <==** **----- Start of picture text -----**<br> Shunt Trip<br>Single Pole<br>**----- End of picture text -----**<br> Two Pole ( 1 pole shunt) **==> picture [247 x 107] intentionally omitted <==** **----- Start of picture text -----**<br> SHUNT LOAD SHUNT<br>2 4<br>LOAD LOAD<br>LINE 1 LINE LINE 3<br>LINE<br>WHITE LEAD WHITE LEAD<br>7.00 ± 0.50 7.00 ± 0.50<br>[177.8 ± 12.7] [177.8 ± 12.7]<br>**----- End of picture text -----**<br> ## **Relay Trip** This permits the overload sensing coil to be placed in a circuit which is electrically isolated from the contacts. The coil may be actuated by sensors monitoring pressure, flow, temperature, speed, etc. Other typical applications include crowbar, interlock and emergency/rapid shutdown circuitry. Trip may be accomplished by voltage or current, which must be removed after trip. Relay Trip (Note A) Single Pole Two Pole (1 pole relay) **==> picture [257 x 108] intentionally omitted <==** **----- Start of picture text -----**<br> 2 COILLOAD 2 4 LOAD COIL<br>COIL COIL<br>1 LINE LINE 1 LINE LINE 3<br>LINE<br>WHITE LEAD WHITE LEAD<br>7.00 ± 0.50 7.00 ± 0.50<br>[177.8 ± 12.7] [177.8 ± 12.7]<br>**----- End of picture text -----**<br> Note A: Coil Ratings to 5 amperes maximum. Contact ratings are 7.5 amperes at 50 Vdc and 250 Vac; 15 amperes at 120 Vac; 32 Vdc. Note: Tolerance ± .005 [.13] unless noted. Dimensions in Brackets [ ] are millimeters. _SNAPAK_ _**®** Series - Configurations_ http://airpax.sensata.com **61** Auxiliary Switch (Note B) Single Pole ## **Auxiliary Switch** This is furnished as an integral part of a series pole in single or, multi-pole assemblies. Isolated electrically from the protector s circuit, the switch works in unison with the power contacts and provides indication at a remote location of the protector’s ON-OFF status. ## **Voltage Trip** Sometimes called “dump circuits” or “panic trip circuits,” these units make it possible to open main power contacts with lower power inputs from one or more sources. This configuration is becoming increasingly more important for sensitive circuitry and denser packaging in automation systems. Available in series, shunt or relay configurations. **==> picture [224 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> 2<br>CN 0.093 0.040 [1.02] DIA. HOLE<br>C (FOR SOLDER ATTACHMENT)<br>N<br>O [2.36]<br>1 LINE<br>**----- End of picture text -----**<br> **==> picture [244 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> .100 to 20.0 amps, VDE, TÜV >20amps<br>NON-VDE & & U3 Construction<br>NON-TÜV >20amps<br>.560 ± 0.030<br>LOAD LOAD [14.22 ± 0.76]<br>C NC<br>NC NO<br>NO C<br>LINE LINE<br>BREAKER SHOWN BREAKER SHOWN<br>IN OFF POSITION IN OFF POSITION<br>**----- End of picture text -----**<br> Auxiliary Switch (Note B) Two Pole ## **Power Switch** In the event that over-current protection is not desired, the coil mechanism can be deleted, providing an excellent low cost single or double-pole power switch. Maximum current rating is 20 amps. **==> picture [223 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> 2 4<br>CN 0.093 0.040 [1.02] DIA. HOLE<br>C (FOR SOLDER ATTACHMENT)<br>N<br>O [2.36]<br>1 LINE LINE 3<br>**----- End of picture text -----**<br> **==> picture [245 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> .100 to 20.0 amps, VDE, TÜV >20amps<br>NON-VDE & & U3 Construction<br>NON-TÜV >20amps<br>.560 ± 0.030<br>LOAD LOAD<br>[14.22 ± 0.76]<br>C NC<br>NC NO<br>NO C<br>LINE LINE<br>BREAKER SHOWN BREAKER SHOWN<br>IN OFF POSITION IN OFF POSITION<br>**----- End of picture text -----**<br> Note B: Switch is located in the left hand pole (viewed from terminal end). _SNAPAK_ _**®** Series - Configurations_ **62** **==> picture [612 x 61] intentionally omitted <==** ## **OPERATING CHARACTERISTICS** ## **Inrush Pulse Tolerance** Many circuit protector applications involve a transformer turn-on, an incandescent lamp load, or a capacitor charge from a DC source. Each of these applications has one common factor: a steep transient of very high current amplitude and short duration. This takes the form of a spike or a single pulse and is the cause of most nuisance tripping associated with magnetic circuit breakers. SNAPAK[®] will withstand, without tripping, a single pulse of 8 milli-seconds duration (half sine wave configuration) and peak amplitude of 9 times its rating without the inertia wheel and 13 times its rating with an inertia wheel. (Not applicable to instant trip delays). ## **MAXIMUM DCR AND IMPEDANCE** |**MAXIMUM DCR AND IMPEDANCE**|**MAXIMUM DCR AND IMPEDANCE**|**MAXIMUM DCR AND IMPEDANCE**|**MAXIMUM DCR AND IMPEDANCE**| |---|---|---|---| |**Current Ratings**<br>**(Amps)**|**T/R/PP/PR**<br>**DC Resistance**|**T/R/PP/PR**<br>**50/60Hz Impedance**|**CR/CPP/CPR**<br>**DC Resistance**| |.100|175|181|274| |.500|6.34|6.63|9.77| |1.00|1.63|1.69|2.31| |2.00|.400|.425|.465| |3.00|.175|.188|.261| |4.00|.103|.106|.156| |5.00|.076|.078|.091| |7.50|.038|.039|.053| |10.0|.026|.028|.023| |12.5|.020|.021|.020| |15.0|.013|.014|.010| |20.0|.010|.011|.008| |25.0|||.004| |30.0|||.003| |_DCR and Impedance is measured after 1 hour at 100% rated current_<br>_using the Voltmeter-Ammeter Method._|||| ## **PULSE TOLERANCE** |**PULSE TOLERANCE**|**PULSE TOLERANCE**| |---|---| |**Delay**|**Pulse Tolerance**| |1, 2, 61, 62|*9 Times Rated Current| |3, 4, 61F, 62F|*13 Times Rated Current| |_* Units above 15 amps are derated to 8 and 12 times rated current_|| ## **PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)** |**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)**|**PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)**| |---|---|---|---|---|---|---|---| |**Delay**|**100%**|**135%**|**150% ***|**200%**|**400%**|**600%**|**800%**| |Instant|No Trip|MayTrip|.100 Max|.100 Max|.100 Max|.100 Max|.100 Max| |Fast|No Trip|.3 to 7|.2 to 5|.1 to 2|.03 to .50|.015 to .30|.010 to .150| |Slow|No Trip|3 to 70|2 to 40|1 to 15|.10 to 4.0|.015 to 2.0|.010 to .800| |_* Minimum trip for all instantaneous and 400Hz units._|||||||| _SNAPAK_ _**®** Series - Operating Characteristics_ http://airpax.sensata.com **63** **==> picture [204 x 364] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 INSTANT<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>135<br>PERCENT OF RATED CURRENT<br>10000<br>1000 FAST<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>135<br>PERCENT OF RATED CURRENT<br>TIME IN SECONDS MAY TRIP<br>TIME IN SECONDS MAY TRIP<br>**----- End of picture text -----**<br> ## **DELAY CURVES & SPECIFICATIONS** ## **400 Hz, DC, 50/60Hz Delay Curves (typ)** A choice of delays is offered for DC, 50/60Hz and 400Hz applications. Delays 0, 49, 59 and 69 provide fast-acting, instantaneous trip and are often used to protect sensitive electronic equipment (not recommended where known inrush exists). Delays 1, 41, 51 and 61 have a short delay for general purpose applications. Delays 2, 42, 52 and 62 are long enough to start certain types of motors and most transformer and capacitor loads. ## **Trip Free** Will trip open on overload, even when forcibly held on.This prevents operator from damaging the circuit by holding handle in the ON position. ## **Trip Indication** The operating handle moves forcibly and positively to the OFF position on overload. ## **Ambient Operation** Operates normally in temperatures between –40° C and +85°C. ## **Insulation Resistance** Not less than 100 megohms at 500Vdc. ## **Dielectric Strength** Withstands 1500 volts, 60Hz for 60 seconds or 1800Vac for one second between all electrically isolated terminals. ## **Endurance** **==> picture [206 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000 SLOW<br>100<br>10<br>1<br>.1<br>.01<br>.001<br>0 100 150 200 300 400 500 600 700 800 900 1000<br>135<br>PERCENT OF RATED CURRENT<br>MAY TRIP<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> Mechanical life in excess of 50,000 operations. In many applications, however, contact wear due to the electrical load determines unit life. At maximum electrical ratings, the SNAPAK[®] can perform 10,000 operations at rated current and voltage. Under UL 1077, the SNAPAK[®] can perform 50 operations at 150% of maximum rated current followed by 6,000 operations at maximum rated current. Under EN60934 the SNAPAK[®] can perform 6,000 electrical operations. After any endurance cycle, the breaker will calibrate and have working dielectric strength. _SNAPAK_ _**®** Series - Delay Curves_ **64** **==> picture [612 x 61] intentionally omitted <==** ## **AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)** |**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**|**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**|**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**|**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**|**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**|**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**|**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**|**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**|**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**|**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**|**AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS)**| |---|---|---|---|---|---|---|---|---|---|---| |**Voltage (Volts), Frequency (hz), Phase, Min Poles, TC, OL**||||||**Current (Amps)**||**Short Circuit Current Rating (Amps)**||| |||||||||||| |Voltage|Frequency (Hz)|Phase|Min. Poles|TC|OL|UL/CSA|TUV|UL 1077 & CSA|TUV|Notes| |32|DC|-|1|1|0|.10-30(3)|.10-20|U1, 1000|500|| |38|DC|-|1|1|0|.10-15|-|U2, 1000 / U1, 1000|-|PR only| |65|DC|-|1|1|0|.10-7.5|-|U2, 500 /U1, 500|-|| |65|DC|-|2|1|0|.10-15|-|U1, 1000|-|| |65|DC|-|2|1|0|.10-20|.10-20|U2, 500 / U1, 500|500|| |65(2)|DC|-|1|1|0|.10-30|.10-30|U2, 120|120|R, PP, PR only| |65(2)|DC|-|2 only|1|0|.10-25|-|U1, 100|-|R only| |65(2)|DC|-|2|1|0|.10-25|-|U2, 500|-|R only| |125|50/60|1|1|1|0|.10-20|7.6-20|U1, 1000|500|| |125|50/60|1|1|1|0|.10-30(3)|-|U1, 1000|-|T only| |125(2)|50/60|1|1|1|0|.10-30|-|U2, 1000|-|R, PP, PR only| |125(2)|50/60|1|1|1|1|.10-30|20.1-30|U3, 300(1)|500|R, PP, PR only| |120/240|50/60|1|2|2|0|.10-20(3)|-|U2, 1000|-|| |120/240|50/60|1|2|2|0|.10-30(3)|-|U1, 650|-|| |125/250|50/60|1|2|2|0|.10-20|-|U1, 1000|-|| |250|50/60|1|1|2|0|.10-20|.1-7.5|U1, 500|500|| |250|50/60|1|1|1|0|.10-7.5|-|C1, 1000(4)|-|| |250|50/60|1|2|2|0|.10-20|.10-20|U1, 1000|500|| |250(2)|50/60|1|2|1|1|.10-30|-|U3, 300|-|R only| |125|400|1|1|2|0|.10-20|-|U1, 1000|-|| |125/250|400|1|2|2|0|.10-20|-|U1, 1000|-|| |250|400|1|2|2|0|.10-20|-|U1, 1000|-|| |250|400|1|1|2|0|.10-7.5|-|U1, 1000|-|| |CR/CPP/CPR COMMUNICATIONS EQUIPMENT CIRCUIT BREAKERS||||||||||| |65|DC|-|1 only|-|-|.10-30|.10-30|1000|1000|| |80|DC|-|1 only|-|-|.10-30|.10-30|600|600|| |(1) Non-standard construction. “Fit For Further Use” approval; (2) Non-snap action design; (3) No auxiliary switch available above 20A; (4) With 30A max. series fuse||||||||||| ## General notes: All supplementary protectors are of the overcurrent (OC) type The family of protectors has been evaluated for end use application for use group (UG) A The terminals (FW) are suitable for factory wiring only (0) The maximum voltage ratings for which the protectors have been tested are shown in the chart The current is the amperage range that the protectors have been tested The tripping current (TC) for the protectors is either “1” (in the range of 125% to 135% of ampere rating) or “2” (more than 135% of ampere rating) The overload rating (OL) – designates whether the protector has been tested for general use or motor starting applications. 0 – tested at 1.5 times amp rating for general use 1 – tested at 6 times AC rating or 10 times DC rating for motor starting The short circuit current rating (SC) – The short circuit rating in amperes following a letter and number designating the test conditions and any calibration following the short circuit test is defined below: |**AUXILIARY SWITCH RATING**|**AUXILIARY SWITCH RATING**|**AUXILIARY SWITCH RATING**|**AUXILIARY SWITCH RATING**| |---|---|---|---| |**Silver**|||| |3.0 amps|@|120 VAC|–––| |1.5 amps|@|–––|32 VDC| |**Gold**|||| |.100 amps|@|32 VAC|32VDC| ||||| |**APPROXIMATE WEIGHT PER POLE**|||| |||Ounces|Grams| |Rocker Confguration||0.9|25| |Toggle, PP, PR||1.2|32| - C – Indicates short circuit test was conducted with series overcurrent protection U – Indicates short circuit test was conducted without series overcurrent protection - 1 – Indicates a recalibration was not conducted as part of the short circuit testing - 2 – Indicates a recalibration was performed as part of the short circuit testing - 3 – Indicates recalibration was performed along with the dielectric and voltage withstand for “Suitable for Further Use” rating Short Circuit Interrupting Capacity 1000 amperes maximum for UL and CSA, 500 amperes maximum for TUV. Consult factory for details. Handle and Body Material The handle and upper body material is polycarbonate and the lower body is PET. Chemical Resistance Handle and case may be cleaned with detergents or alcohols and should be restricted to outside surfaces only. Organic solvents are not recommended. Special attention should be given when solvents are used to remove excess flux from terminals. No oils or lubricants should be introduced into handle openings or onto bushing threads. IEC, UL, CSA, SEV, VDE, CCC, CE, TÜV Recognized by UL to STD-1077 and UL certified to spacing requirements of IEC 950 for basic and functional insulation for front panel mounting. Certified by CSA, file number LR26229 as recognized supplementary protectors, SEV approved, CCC approved, TÜV approved (including screw terminals) to EN60934. TUV approval of unmarked rocker handle option for appliance disconnect requires status of protectors to be indicated on the panel. Only TUV approved part numbers will be marked CE compliant. See shaded areas of part number decision tables for approved configurations and/or consult factory for exceptions and limitations. Shock Withstands 75G without tripping while carrying full rated current per MIL-STD-202, Method 213, Test Condition I. Instant trip breakers are tested at 80% of rated current. Vibration Time delayed units withstand 10G without tripping while carrying full rated current per MIL-STD-202, Method 204, Test Condition A. Instant trip breakers are tested at 80% of rated current. UL 489A Listed The CR, CPP and CPR are dimensionally the same as the popular R, PP and PR Snapack products, but provide UL listing to UL489A for Communications Equipment. Available only in single pole with DC trip time delays for series or series with silver auxiliary switch configurations. As a circuit breaker, the CR, CPP or CPR provides communication equipment manufacturers with a UL listed circuit breaker in an extremely compact package that meets the stringent environmental requirements of today’s marketplace. This makes the CR, CPP and CPR ideal for switching, transmission and wireless applications. _SNAPAK_ _**®** Series - Specifications_ http://airpax.sensata.com **65** **==> picture [87 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Paddle Handle Hardware<br>**----- End of picture text -----**<br> **==> picture [251 x 324] intentionally omitted <==** **----- Start of picture text -----**<br> ON<br>O O<br>F N<br>F<br>OFF<br>– A – B<br>Vertical Mount Horizontal Mount<br>0.680 0.125 0.680 0.180<br>[17.27] [3.18] [17.27] [4.57]<br>– 10 & –11 – 20 & –21<br>Knurled Nut Panel Dress Nut<br>0.625 0.680<br>0.125 0.031<br>[15.88] [17.27]<br>[3.18] [0.79]<br>– 31 – L<br>Hex Nut Locking Ring (Toggle)<br>**----- End of picture text -----**<br> ## **HARDWARE** ## **Indicator Plates** SNAPAK[®] toggle handle circuit protectors may be specified with indicator plates for either vertical or horizontal mounting.The “ON-OFF/O-I” plate is standard. ## Note 1: To allow for installation clearances, the minimum recommended distances between centers of panel openings should be: |**RECOMMENDED CENTER DISTANCES FOR PANEL OPENINGS**<br>Breaker Type<br>Distance, inches [mm]|**RECOMMENDED CENTER DISTANCES FOR PANEL OPENINGS**<br>Breaker Type<br>Distance, inches [mm]| |---|---| |<br>T11<br>T21|<br>0.750 [19.05]<br>1.375 [34.93]| |PP11 & PR11|0.750 [19.05]| |PP21 & PR21|1.375 [34.93]| |R11|0.805 [20.45]| |R21|1.429 [36.30]| Note 2: Torque on mounting hardware is not to exceed 25 inch-pounds for 1/2 inch bushings or 15 inch-pounds for 3/8 inch bushings. ## **Mounting Nuts (Toggle)** **==> picture [200 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> Push-Pull & Push-to-Reset Hardware<br>0.534 0.156<br>[13.56] 0.078 [3.96]<br>[1.98]<br>3/8 - 32 Panel Nut<br>Bright Nickel<br>0.500<br>0.156<br>[12.7]<br>[3.96]<br>3/8 - 32 Hex Nut<br>Bright Nickel<br>**----- End of picture text -----**<br> A choice of knurled, dress and hex nuts are available. All three are available in bright nickel. The knurled and dress nuts are also available in a matte black finish. Every SNAPAK[®] comes with a hex nut, but you may order the front panel nuts which will best enhance your design. ## **Miscellaneous Hardware** SNAPAK[®] circuit protectors with 1/2-32 thread may also be equipped with optional locking rings to prevent rotation of the unit after it is installed. ## **3/8 - 32 Hex Nut and Panel Nuts** The hardware will be supplied with each Push-Pull (PP) and Push-to-Reset (PR). ## **3/8 - 32 Panel Nut** This nut when reversed will provide alignment in .437 (11.1) and .468 (11.88) diameter round panel holes. Note: Tolerance ± .010 [.25] unless noted. Dimensions in brackets [ ] are millimeters. _SNAPAK_ _**®** Series - Hardware_ **66** **==> picture [612 x 61] intentionally omitted <==** ## **HOW TO ORDER** The ordering code for the SNAPAK[®] circuit protectors may be determined by following the steps in the decision tables shown here. The coding given permits a self-assigning part number, with certain limitations (due to the adaptability of magnetic protectors to complex circuits), requires a factory-assigned part number. The example shown is the code for a paddle handle, single pole (UL construction), series circuit protector designed for operation of a 50/60Hz/ DC circuit. A slow time delay and rating of 5 amperes has been indicated. Handle color is black, and a bright nickel knurled nut, vertical mount (ON-OFF) indicator plate and locking ring are to be supplied. To determine the ordering code for your particular SNAPAK[®] unit, simply follow the steps shown, then fill in the letters and/ or numbers in the boxes. Space is available on the circuit breaker label for your part number (up to 12 digits). You may then use your own part number to place an order or as a reference for further questions you may have. This option does require a factory assigned part number for traceability to your drawing or internal part number. **==> picture [417 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> 1 First Decision<br>Handle Poles Configurations* Terminals<br>T Paddle Handle 1 Single Pole † 0 Switch Only (Note E) Quick Connects (leave blank)<br>PP Push-Pull 4 Single Pole †† 1 Series Circuit Protector S Screw Terminals,<br>Single pole (-1) and series only<br>PR Push-To-Reset 2 Two Pole † 3 Shunt Circuit Protector<br>R Rocker 5 Two Pole †† 4 Relay Circuit Protector †††† (5th decision, group V - screw<br>terminal option is required<br>CR Rocker ** 5 Series w/ Silver Aux. Switch ††† when 1st decision "S" is<br>CPP Push-Pull ** 6 Series w/ Gold Aux. Switch ††† specified)<br>CPR Push to Reset ** 9 Mixed Construction [(] 2 Pole Only [)]<br> † UL & CSA Construction<br>**----- End of picture text -----**<br> - †† Non UL & CSA Construction ††† Auxilary Switch is located in the left hand pole (viewed from terminal end) †††† Does not meet spacings for many IEC / TUV equipment specs. Consult factory for additional information. - Multi-pole units with mixed construction, poles numbered left to right when viewed - from terminal end. Shunt or relay construction available in pole 2 only, other pole must be a series or switch only construction. - **UL 489A listed, available in 1 pole series or series w/silver aux. switch. DC delay only **==> picture [138 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> T11 - 2- 5.00A - 01-11AL- V<br>**----- End of picture text -----**<br> **==> picture [316 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 Second Decision<br>Frequency & Delay<br>-0 Instant DC-50/60 Hz<br>-1 Fast DC-50/60 Hz<br>-2 Slow DC-50/60 Hz<br> -3 Fast w/ Inertia Wheel<br>[ DC-50/60 Hz] 3 Third Decision<br>[-4 ] Slow w/ Inertia Wheel<br>[DC-50/60 Hz] Rated Current<br> -41* Fast 400 Hz***<br>-42* Slow 400 Hz* Circuit Breaker Construction<br>-49* Instant 400 Hz Use three numbers to print required<br>-51 Fast DC [+] current value between .100 amps<br>-52 Slow DC [+] minimum and 30.0 amps maximum.<br>-59 Instant DC+<br>For example, use:<br>-61 Fast 50/60 Hz* .100 or 2.00 or 10.0<br>-62 Slow 50/60 Hz*<br> Switch Only Construction<br>-69 Instant 50/60 Hz<br>- S Switch Pole or Special Delay -SW Maintained SPST & DPST<br>* 20 amps max for 400Hz Note: 20.0 amps max for 400 Hz units.<br>**For addition of Inertia Delay an "F" may<br> be added to delay 41, 42, 51, 52, 61, 62 only<br>+CR, CPP, CPR only available in these delays<br>**----- End of picture text -----**<br> Notes: - A A neon bulb is provided when specified for 120Vac and 250Vac operation. For operation at 120Vac a 33,000 ohm, 1/2 watt external resistor is required. At 250Vac a 100,000 ohm, 1 watt external resistor is required. - B An LED with 750 ft. L @ 20mA is provided in the center of the handle. Maximum power dissipation @ 25°C is 135mW. Continuous forward current is 20mA. Forward voltage, typical, is 1.6v at 20mA. Reverse current, typical, is 100mA @ 3.0 volts. An external resistor may be required to limit current to these values. - C When ordering Paddle Handles, you may choose one item from each hardware group to add to 5th decision if such items are desired. For example, “-11ALCA” would indicate a bright nickel knurled nut, plus a vertical mount indicator, plus a locking ring, plus #8-32 screw terminal, straight with tabs. - D All units except Rocker units will have (1) hex nut installed as standard hardware for the back of a panel. The choices in the fifth decision table are intended for the front or visible side of the panel and are offered for Paddle Handle configuration only. Push-Pull and Push-to-Reset configurations include one (1) panel nut and one (1) hex nut as standard hardware. - E Switch only — no current overload protection provided. - F. CCC Approval - If CCC is required on this product, please inform Sensata to have this product manufacturered in our China facility _SNAPAK_ _**®** Series - Decision Tables_ **67** 4 Fourth Decision ## [Rocker] > [Step 1: Choose Letter For Body Color] **B** Black **R** Black w/ Handle guard **G** Gray **[S]**[Gray w/ Handle guard] **W** White **[T]** White w/ Handle guard Example: “W...” For White Rocker Body (Rocker Style) Step: 2: Choose Handle Combinations Without Illumination Basic Handle Color[(w/o Markings)] - **01** Black **02** Red **06** White **07** Orange Example: “-W06” With Illumination Basic Handle Color & Light Choice (w/o Markings) - **101** Clear w/Neon[(] Note A[)] - **102** Clear w/Green Glow Neon[(] Note A[)] - **103** Clear w/Red LED[(] Note B[)] - **104** Clear w/4-8 Vdc Red LED - **105** Clear w/8-16 Vdc Red LED - **107** Clear w/Green LED (Note B) - **108** Clear w/4-8 Vdc Green LED - **109** Clear w/8-16 Vdc Green LED - **121** Transparent Red w/Neon (Note A) - **123** Transparent Red w/Red LED (Note B) - **124** Transparent Red w/Red LED 4-8 Vdc - **125** Transparent Red w/Red LED 8-16 Vdc - **161** Translucent White w/Neon[(] Note A[)] - **162** Translucent White w/ Green Glow Neon (Note A) - **171** Transparent Amber w/Neon[(] Note A[)] - **181** Transparent Smoke Gray w/Neon[(] Note A[)] - **182** Transparent Smoke Gray w/Green Glow Neon[(] Note A[)] - **183** Transparent Smoke Gray w/Red LED[(] Note B[)] - **184** Transparent Smoke Gray w/4-8 Vdc Red LED - **185** Transparent Smoke Gray w/8-16 Vdc Red LED - **187** Transparent Smoke Gray w/Green LED[(] Note B[)] - **188** Transparent Smoke Gray w/4-8 Vdc Green LED - **189** Transparent Smoke Gray w/8-16 Vdc Green LED Example: “-W124” If you prefer NO markings, then your handle decision is now complete. **==> picture [235 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> Step 3: Choose Handle Markings<br>Marked For Vertical Mount-After choice of 3 digit number in step 2 above.<br>ON<br> I ON I<br>OFFO OFF O<br>Add “ CV ” Add “ EV ” Add “ IV ”<br>for Combined for English markings. for Intíl.<br>markings. Example: "-W124EV" markings.<br>Marked For Horizontal Mount-After choice of 3 digit number in step 2 above.<br>OFFO ON I OFF ON I<br>Add “ CH ” Add “ EH ” Add “ IH ”<br>for Combined for English for International<br>markings. markings. markings.<br>Example “-W06EH”<br>If you have chosen a handle from this table, your 4th Decision and your<br>catalog part number are now complete (except if you require “-S” screw<br>terminal option from the 5th Decision Table.)<br>O<br>**----- End of picture text -----**<br> - Paddle[(] T[)] Handle Color - **-01** Black **-02** Red **-03** Yellow **-04** Green **-05** Blue **-06** White If you have chosen a handle from this table, your 4th Decision is now complete except for hardware options in 5th Decision Table. ## Push-Pull[(] PP, CPP and CPR[)] **-XX** No Button Markings desired (not available for CPP & CPR) **-OA** 5 Marked Buttons Available For These Amperages 0.1 1 10 **-OB** .25 2.5 15 0.5 5 17.5 **-OC** .75 7.5 20 If you have chosen a handle from this table, your 4th Decision & your catalog PN are now complete (except if you require “-S” screw terminal option from the 5th Decision Table.) Push-to-Reset (PR) **-XX** No Button Markings Only If you have chosen a handle from this table, your 4th Decision and your catalog PN are now complete (except if you require “-S” screw terminal option from the 5th Decision Table.) **==> picture [63 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> 5 Fifth Decision<br>**----- End of picture text -----**<br> ## Hardware & Accessories (Notes C and D) **==> picture [518 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> Group I Group II (Indicator Plate) Group V (Screw Terminal Options)<br>-00 No Outer Hardware Desired<br>-10-11 Black Knurled Nut Bright Nickel Knurled Nut -A [(] Vertical MountOff/On & O/I [)] * -C Straight TerminalSAE 8-32, Upturned Lugs (Tabs) -F Straight TerminalM4, Upturned Lugs (Tabs)<br>-20 Black Panel Dress Nut<br>-21 Bright Nickel Panel Dress Nut -B (Off/On & O/I)*Horizontal Mount -D Straight TerminalSAE 8-32, Bus-Type Connect (Flat) -H Straight TerminalM4, Bus-Type Connect (Flat)<br>-31 Bright Nickel Hex Nut<br>Group III<br>-L Locking Ring *Selection of A or B Indicator Plate Please select a screw terminal option if you<br> required for TUV and CCC. selected “S” in Decision 1<br>**----- End of picture text -----**<br> ## **T, V** = TÜV and CCC Approved The shaded areas denote CCC (if applicable) and CE compliant options. The V will be added to any part number formed entirely from shaded decisions. If non-shaded areas are selected, the unit will not be approved, nor CE compliant, but other approvals still apply. 20 amps max rating on units.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →