CL11
Data Logger, 0-100%RH, 0 to 50°C Temp Range, Carbon Dioxide, Humidity & Temperature, 1 Channel
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ROTRONIC
- Product type:
- SVHC: No SVHC (04-Feb-2026)
- Display Type: LCD
- Product Range: -
- Data Interface: USB
- Maximum Samples: 40000 Samples
- Data Logger Type: Carbon Dioxide, Humidity & Temperature
- No. of Channels / Inputs: 1 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 603.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
CO 2 Measuring instruments ## **CO DISPLAY 2 /CL11/CP11** ## **Benefits** - Measures and logs CO2, relative humidity and temperature - Rotronic HYGROMER® IN-1 humidity sensor - Up to 40,000 data point memory ## **Applications** **==> picture [231 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> CP11<br>CO2 display CL11<br>**----- End of picture text -----**<br> - Indoor air quality: classrooms, kindergartens, meeting rooms, open-plan offices, shopping centers, fitness studios ## **General Information** **==> picture [488 x 335] intentionally omitted <==** **----- Start of picture text -----**<br> Order code CO2 Display CL11 CP11<br>Sensors / Calibration • HYGROMER [®] IN-1 humidity sensor<br>• Calibration of humidity possible at 35/80 %RH<br>• NDIR sensor with automatic calibration (ABC)<br>• Manual calibration of CO2 at 400 ppm<br>Display • Large, easy-to-read display of measured values Large display with backlight<br>• CO2 indicator for quick recognition of air quality<br>(GOOD/NORMAL/POOR)<br>• REC LED to indicate data<br>recording is in progress<br>• Display of date and time<br>Control panel Large buttons for easy operation of the measuring instrument<br>Connections • Port for USB stick for data downloads • Mini USB port for connection to a PC<br>• 12 VDC power supply • 5 VDC power supply, for connection of the optionally<br>available AC adapter<br>Guidelines for a healthy indoor climate<br>1000 1500 40 [50] 60 20 30<br>30 70<br>500 2000 20 80 10 40<br>oTeTe 10 90<br>0 2500 0 100 0 50<br>CO 2 [ppm] rh [%] T [°C]<br>a =| -_ =J a ry|<br>Recommendation: 800 - 1200 ppm Recommendation: 40 - 60 % Recommendation: 22 - 24 °C<br>Optimum: 800 ppm Winter: 30 % Winter: 21 °C<br>Maximum: 1400 ppm Summer: 60 % Summer: 26 °C<br>**----- End of picture text -----**<br> 1 **www.rotronic.com** ## **Technical Information** ||~~Bae~~|~~Bae~~|~~Bae~~| |---|---|---|---| ||CO2Display<br>~~Bae~~|CL11<br>~~Bae~~|CP11<br>~~Bae~~| |General Specifications<br>~~a~~|||| |Type<br>~~a~~<br>~~ee~~|Wall or benchtopdisplayunit<br>~~a~~|Benchtopdisplayunit<br>~~a~~|Handheld device<br>~~a~~| |Parameters<br>~~ee~~|CO2, relative humidity and temperature||CO2, relative humidity, temperature,<br>dewpoint & wet bulb temperature| |Application range<br>~~ee~~<br>~~a~~<br>~~es~~|0...50 °C/0...95 %rh,non-condensing<br>~~ee~~|0...50 °C/0...100 %rh,non-condensing<br>~~ee~~|| |Clock<br>~~a~~<br>~~es~~<br>~~ee~~|Real time clock with 4 min. battery backup<br>~~ee~~<br>~~ee~~|Real time clock with 2 min. battery<br>backup<br>~~ee~~<br>~~ee~~|Real time clock<br>~~ee~~<br>~~ee~~| |Alarm / Indicator<br>~~es~~<br>~~ee~~|Adjustable for CO2measurement (visual)<br>~~ee~~<br>~~ee~~|Adjustable for CO2measurement<br>(visual & audible)<br>~~ee~~<br>~~ee~~|Adjustable for CO2measurement<br>(audible)<br>~~ee~~<br>~~ee~~| |Instrument-Specific Data<br>~~eeee~~|||| |Current consumption<br>~~eG~~|700 mA<br>~~eG~~|50 mA<br>~~eG~~|40 mA<br>~~eG~~| |Warm-uptime|<1 min.||| |Memory capacity|• 19,500 values with time stamp<br>• Automatic recording<br>(%rh/°C/ppm)|• 40,000 values with time stamp<br>• Automatic recording<br>(%rh/°C/ppm)|• 18,000 values with time stamp<br>• Automatic recording (%rh/°C/ppm)<br>• 99 single values with time stamp<br>• Manual recording<br>(%rh/°C/DP/WBT/ppm)| |CO2Measurement<br>~~|~~|||| |Measurementprinciple|Infrared(NDIR)with automatic calibration(ABC)||| |Measuringrange<br>~~SI~~|0.....9999ppm<br>~~a~~<br>~~—]~~<br>~~SI~~||| |Accuracyat 23 °C ±5 K<br>~~ooo~~<br>~~SI~~|±30ppm ±5 % of the measured value@0...5000ppm<br>~~ooo~~<br>~~a~~<br>~~—]~~<br>~~SI~~||| |Resolution<br>~~ooo~~<br>~~SI~~|1ppm<br>~~ooo~~<br>~~a~~<br>~~—]~~<br>~~SI~~<br>~~ao~~||| |Adjustmentpoint<br>~~ooo~~<br>~~SI~~|400ppm<br>~~ooo~~<br>~~a~~<br>~~—]~~<br>~~SI~~<br>~~ao~~||| |Pressure dependence<br>~~SI~~|+1.6 % reading per kPa<br>~~a~~<br>~~—]~~<br>~~SI~~<br>~~ao~~||| |Null drift<br>~~SI~~<br>~~oo~~|<10ppm/year<br>~~a~~<br>~~—]~~<br>~~SI~~<br>~~ao~~<br>~~oo~~||| |Maintenance<br>~~oo~~|No maintenance(standard indoor applications)<br>~~oo~~<br>~~ear~~||| |HumidityMeasurement<br>~~oo~~<br>~~_——oeumae~~<br>~~ear~~|||| |Humiditysensor<br>~~_——oeumae~~|ROTRONIC HYGROMER®IN-1<br>~~_——oeumae~~<br>~~ear~~||| |Measuringrange<br>~~oo~~|0...100 %rh<br>~~ear~~<br>~~oo~~||| |Accuracyat 23 °C ±5 K<br>~~oo~~|±2 %rh(10…90 %rh),others ±5 %rh<br>~~oo~~||| |Resolution<br>~~oo~~|0.1 %rh<br>~~oo~~||| |Adjustmentpoints<br>~~oo~~|35,80 %rh<br>~~oo~~||| |Response time τ63<br>~~oo~~|<30 s,without filter<br>~~oo~~||| |Long-term stability<br>~~oo~~<br>~~ee~~|<1.5 %rh/year<br>~~oo~~||| |Temperature Measurement<br>~~ee~~<br>~~eeeSeaewcme'_—_—_|:~~|||| |Sensor<br>~~ee~~<br>~~eeeSeaewcme'_—_—_|:~~|NTC thermistor<br>~~eeeSeaewcme'_—_—_|:~~||| |Measuringrange<br>~~ee~~<br>~~So~~|-20...60 °C<br>~~So~~||| |Accuracyat 23 °C ±5 K<br>~~So~~<br>~~II~~|±0.3 K<br>~~So~~<br>~~IITTT~~||| |Resolution<br>~~II~~|0.1 °C<br>~~IITTT~~||| |Response time<br>~~II~~|4 s<br>~~IITTT~~||| |Software<br>~~II TTT~~<br>~~a~~|||| |HW4(SW21)<br>~~a~~|Available as download at www.rotronic.com<br>~~a~~<br>~~iaioeaomVm~~<br>~~roe~~||| |Conformities/Housing<br>~~a~~<br>~~a~~<br>~~iaioeaomVm~~<br>~~roe~~|||| |CE/EMC compatibility<br>~~a~~|EMC Directive 2014/30/EU,EN 61326-1:2012<br>~~a~~<br>~~iaioeaomVm~~<br>~~roe~~||| |Housingmaterial|ABS<br>~~iaioeaomVm~~<br>~~roe~~||| |Dimensions<br>~~a~~|330 x 250 x 50 mm|157 x 120 x 45 mm|76.7 x 41.8 x 233.9 mm| |Weight|1400g|200g|290g| 2 **www.rotronic.com** ## **Technical Information** **Dimensions CO2 Display** **==> picture [181 x 119] intentionally omitted <==** **----- Start of picture text -----**<br> 52<br>330<br>250<br>**----- End of picture text -----**<br> **==> picture [58 x 28] intentionally omitted <==** **----- Start of picture text -----**<br> 130<br>65<br>**----- End of picture text -----**<br> ## **Dimensions CL11** **==> picture [322 x 136] intentionally omitted <==** **----- Start of picture text -----**<br> 44 mm<br>120 mm<br>45 mm<br>62 mm<br>157 mm<br>85 mm<br>**----- End of picture text -----**<br> ## **Dimensions CP11** **==> picture [144 x 241] intentionally omitted <==** **----- Start of picture text -----**<br> 15<br>**----- End of picture text -----**<br> 3 **www.rotronic.com**
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →