Image not available
Illustrative purposes only
C53TP50CH
SOLID STATE RELAYS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA/CRYDOM
- Product type:
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 264.47 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **53TP SERIES | IP20** PANEL MOUNT SOLID STATE RELAYS ## Features - 3-phase solid state relay - Ratings 25 A, 50 A per phase @ 48-530 VAC - 2 package styles IP20 or IP00 (See IP00 datasheet for more information) - SCR output for heavy industrial loads - AC or DC control - Zero voltage (resistive loads) or instantaneous (inductive loads) output - LED input status indicator - Transient protection built-in ## **PRODUCT SELECTION** |**Control Voltage**|**25 A**|**50 A**| |---|---|---| |**90-140 VAC**|B53TP25C|B53TP50C| |**180-260 VAC**|C53TP25C|C53TP50C| |**4-32 VDC**|D53TP25C|D53TP50C| |**18-36 VAC**|E53TP25C|E53TP50C| ## **SPECIFICATIONS** ## AC Output[(1)] |**Description**|**25 A**|**50 A**| |---|---|---| |**Operating Voltage (47-63 Hz) [Vrms]**|48-530|48-530| |**Transient Overvoltage [Vpk](2)**|1200|1200| |**Maximum Off-State Leakage Current @ Rated Voltage**<br>**[mArms]**|3|3| |**Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] (2)**|500|500| |**Maximum Load Current [Arms](3)**|25|50| |**Minimum Load Current [Arms]**|0.1|0.1| |**Maximum 1 Cycle Surge Current (50/60 Hz) [Apk]**|275/300|710/750| |**Maximum 1 Second Surge Current (50/60 Hz) [Apk]**|85|150| |**Maximum On-State Voltage Drop @ Rated Current [Vpk]**|1.35|1.35| |**Thermal Resistance Junction to Case (Rjc) [°C/W]**|0.24|0.12| |**Maximum 1/2 Cycle I²t for Fusing (50/60 Hz) [A² sec]**|380/370|2520/2320| |**Minimum Power Factor (with Maximum Load)**|0.5|0.5| |**UL/IEC 60947 Motor Control Ratings at 120V [HP/KW](4)**|0.75/0.56|1.5/1.11| |**UL/IEC 60947 Motor Control Ratings at 240V [HP/KW](4)**|1/0.74|3/2.22| |**UL/IEC 60947 Motor Control Ratings at 380V [HP/KW](4)**|2/1.48|5/3.7| |**UL/IEC 60947 Motor Control Ratings at 480V [HP/KW](4)**|3/2.22|7.5/5.55| Copyright © 2024 Sensata Technologies, Inc. www.sensata.com ## Input[(1)] **==> picture [542 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> Description D53 B53 C53 C53<br>Control Voltage Range 4-32 VDC 90-140 VAC 180-260 VAC 18-36 VAC<br>Minimum Turn-On Voltage 4.0 VDC 90 VAC 180 VAC 18 VAC<br>Minimum Turn-Off Voltage 1.0 VDC 10 VAC 10 VAC 2 VAC<br>Minimum Input Current (for on-state) 24 mA 7 mA 7 mA 15 mA<br>Maximum Input Current 35 mA 16 mA 20 mA 20 mA<br>Nominal Input Impedance Current Regulated Current Regulated Current Regulated Current Regulated<br>Maximum Turn-On Time [msec] [(5)] 8.33 20 20 20<br>Maximum Turn-Off Time [msec] 8.33 30 30 30<br>**----- End of picture text -----**<br> ## General[(1)] **==> picture [542 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> Description Parameters<br>Dielectric Strength, Input/Output/Base (50/60 Hz) 4000 Vrms<br>Minimum Insulation Resistance (@ 500 VDC) 10 [9] Ohms<br>Maximum Capacitance, Input/Output 8 pF<br>Ambient Operating Temperature Range -40ºC to 80ºC<br>Ambient Storage Temperature Range -40ºC to 125ºC<br>Weight (typical) 13.1 oz (370g)<br>Encapsulation NA<br>Terminals Hardware Furnished, mounted<br>Screws and Saddle clamps Zinc plated Steel<br>Input Terminal Screw Torque Range: [lb-in/Nm] 8-10 / 0.9-1.1<br>Output Terminal Screw Torque Range: [lb-in/Nm] 15-20 / 1.7-2.2<br>**----- End of picture text -----**<br> ## **THERMAL DERATE INFORMATION** **==> picture [494 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> DERATE CURVES: DERATE CURVES:<br>53TP IP20 25A 53TP IP20 50A<br>50<br>25 2.0˚C/W<br>1.5˚C/W 40<br>20<br>1.0˚C/W<br>1.5˚C/W<br>0.7˚C/W 30<br>15 1.0˚C/W<br>0.5˚C/W<br>0.7˚C/W<br>20<br>10 0.5˚C/W<br>0.2˚C/W<br>5 10<br>0<br>0<br>20 30 40 50 60 70 80<br>20 30 40 50 60 70 80<br>Ambient Temperature [°C]<br>Ambient Temperature [°C]<br>(Amperes) (Amperes)<br>Load Currect Per Channel Load Currect Per Channel<br>**----- End of picture text -----**<br> Page 2 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com ## **MECHANICAL SPECIFICATIONS** Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] **==> picture [255 x 275] intentionally omitted <==** **----- Start of picture text -----**<br> 4.0 [101.3]<br>3.6 [92.0]<br>5/L3 3/L2 1/L1<br>1.87 [47.6] 3.2 [79.7]<br>0.2 [5.1]<br>6/T3 4/T2 2/T1<br>0.8 [19.3]<br>1.5 [38.6]<br>1.45 [36.83]<br>4.09 [103.9]<br>**----- End of picture text -----**<br> **==> picture [548 x 289] intentionally omitted <==** **----- Start of picture text -----**<br> ORDERING OPTIONS Example : D53TP25CH-10<br>D 53TP 25 C H -10<br>Control Voltage<br>B: 90-140 VAC<br>C: 180-260 VAC<br>D: 4-32 VDC<br>E: 18-36 VAC<br>Series<br>53TP<br>Rated Load Current<br>25: 25 Amps<br>50: 50 Amps<br>Cover<br>C: Included (IP20)<br>Relay Options<br>Blank: Not included<br>H: Included<br>Relay Options Required for valid part number<br>Blank: Zero Voltage Turn-On For options only and not required for valid part<br>-10: Instantaneous Turn-On number<br>**----- End of picture text -----**<br> Page 3 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com ## **GENERAL NOTES** 1) All parameters at 25°C unless otherwise specified. - 2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 3) Heat sinking required, see page 3 for derating curves. 4) At 40°C Ambient temperature. 5) Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models) ## **AGENCY APPROVALS & CERTIFICATIONS** **==> picture [77 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> LR56339<br>E79183<br>**----- End of picture text -----**<br> Designed in accordance with the requirements of IEC 62314 EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: IEC 62314 IEC 60068-2-6 35mm / 10-55Hz IEC 60068-2-27 15G / 11ms IEC 1000-4-2 : Electrostatic Discharge – Level 3 IEC 1000-4-3 : Radiated Electromagnetic Noise – Level 3 IEC 1000-4-4 : Electrically Fast Transients – Level 3 IEC 1000-4-5 : Electrical Surges – Level 3 IEC 1000-4-6 : Conducted Electromagnetic Noise – Level 3 ## **WARNINGS** ## RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** ## HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Page 4 Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY, AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (800) 350 2727 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Copyright © 2024 Sensata Technologies, Inc. www.sensata.com Rev. 07/25/24 ECN 21039 FDE-07-01 Rev. B
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →