Image not available
Illustrative purposes only
C22G6
CARTRIDGE FUSES
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON / PARTNER STOCK
- Product type: Cartridge Fuses
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 6 |
| Price | 68.59 € |
| Current stock | 50+ |
| Lead time | 30 days |
## Cylindrical Fuse Links for Industrial Applications Class gG/gL and aM, 0.16 to 125A, 400 to 690Vac ## Class of Operation: gG-gL For general purpose applications aM For motor protection applications Fuse Holders: Refer to data sheet 2143 Standards/Approvals: IEC 60269 Catalogue Symbol: Class gG/gL |Catalogue Symbol:|Catalogue Symbol:|Catalogue Symbol:|Catalogue Symbol:| |---|---|---|---| |Class gG/gL|||| |Size (mm)|Without Indicator<br>(Example)|With Indicator<br>(Example)|With Striker*<br>(Example)| |8 x 31|C08G(amps)<br>(C08G4)|C08G(amps)I<br>(C08G4I)|N/A| |10 x 38|C10G(amps)<br>(C10G4)|C10G(amps)I<br>(C10G4I)|N/A| |14 x 51|C14G(amps)<br>(C14G4)|C14G(amps)I<br>(C14G4I)|C14G(amps)S*<br>(C14G4S)| |22 x 58|C22G(amps)<br>(C22G4)|C22G(amps)I<br>(C22G4I)|C22G(amps)S*<br>(C22G4S)| |Class aM|||| |8 x 31|C08M(amps)<br>(C08M4)|N/A|N/A| |10 x 38|C10M(amps)<br>(C10M4)|C10M(amps)I<br>(C10M4I)|N/A| |14 x 51|C14M(amps)<br>(C14M4)|C14M(amps)I<br>(C14M4I)|C14M(amps)S*<br>(C14M4S)| |22 x 58|C22M(amps)<br>(C22M12)|C22M(amps)I<br>(C22M12I)|C22M(amps)S*<br>(C22M12S)| Description: Cylindrical class gG-gL and aM fuse links are intended for industrial applications. Some industrial fuse links are available with an operated visible fuse indicator. Sizes 14 x 51, 22 x 58 in both class gG-gL and aM are also available with a built-in striker for micro-switch operation and remote indication. ## Packaging: MOQ: please contact our customer service department 00 44 (0) 1509 882 600 or bulesales@cooperindustries.com ## Technical Data: Rated voltage: from 400 to 690Vac Amps: 0.16 to 125A Rated breaking capacity: 20 to 120kA * Striker fuse links can operate a micro-switch for remote fuse link operated indication ## Dimensions - mm Fuse Links - with or without indicator ## Fuse Links with striker |Size<br>(mm)|A|B|C|D|E| |---|---|---|---|---|---| |14 x 51|14|51|13|8|4| |22 x 58|22|58|16|8|4| For striker fuse link applications use CH141DMS or CH221DMS fuse holders with micro-switch auxiliary contacts. 04-06-09 SB-SB09488 Form No Cylindrical Fuse Links Page 1 of 9 Data Sheet 720115 ## Cylindrical Fuse Links for Industrial Applications Class gG/gL, 0.5 to 125A, 400 to 690Vac ## Class gG/gL - Catalogue Numbers |Size (mm)|Current (A)|Catalogue Numbers<br>Without Indicator|Catalogue Numbers<br>With Indicator|Catalogue Numbers<br>With Striker|Voltage (V)|Breaking Capacity<br>(kA)| |---|---|---|---|---|---|---| |8x31|0.5|C08G0.5|-|-|400V|20kA| ||1|C08G1|-|-||| ||2|C08G2|C08G2I|-||| ||4|C08G4|C08G4I|-||| ||6|C08G6|C08G6I|-||| ||8|C08G8|C08G8I|-||| ||10|C08G10|C08G10I|-||| ||12|C08G12|C08G12I|-||| ||16|C08G16|C08G16I|-||| ||20|C08G20|C08G20I|-||| ||25|C08G25|C08G25I|-||| |10x38|0.5|C10G0.5|-|-|500V|120kA| ||1|C10G1|C10G1I|-||| ||2|C10G2|C10G2I|-||| ||4|C10G4|C10G4I|-||| ||6|C10G6|C10G6I|-||| ||8|C10G8|C10G8I|-||| ||10|C10G10|C10G10I|-||| ||12|C10G12|C10G12I|-||| ||16|C10G16|C10G16I|-||| ||20|C10G20|C10G20I|-||| ||25|C10G25|C10G25I|-||| ||32|C10G32|C10G32I|-|400V|| |14x51|1|C14G1|C14G1I|-|690V|80kA| ||2|C14G2|C14G2I|C14G2S||| ||4|C14G4|C14G4I|C14G4S||| ||6|C14G6|C14G6I|C14G6S||| ||8|C14G8|C14G8I|C14G8S||| ||10|C14G10|C14G10I|C14G10S||| ||12|C14G12|C14G12I|C14G12S||| ||16|C14G16|C14G16I|C14G16S||| ||20|C14G20|C14G20I|C14G20S||| ||25|C14G25|C14G25I|C14G25S||| ||32|C14G32|C14G32I|C14G32S|500V|120kA| ||40|C14G40|C14G40I|C14G40S||| ||50|C14G50|C14G50I|C14G50S|400V|| |22x58|2|C22G2|C22G2I|-|690V|80kA| ||4|C22G4|C22G4I|C22G4S||| ||6|C22G6|C22G6I|C22G6S||| ||8|C22G8|C22G8I|C22G8S||| ||10|C22G10|C22G10I|C22G10S||| ||12|C22G12|C22G12I|C22G12S||| ||16|C22G16|C22G16I|C22G16S||| ||20|C22G20|C22G20I|C22G20S||| ||25|C22G25|C22G25I|C22G25S||| ||32|C22G32|C22G32I|C22G32S||| ||40|C22G40|C22G40I|C22G40S||| ||50|C22G50|C22G50I|C22G50S||| ||63|C22G63|C22G63I|C22G63S||| ||80|C22G80|C22G80I|C22G80S|500V|120kA| ||100|C22G100|C22G100I|C22G100S||| ||125|C22G125|C22G125I|C22G125S|400V|| 04-06-09 SB-SB09488 Form No Cylindrical Fuse Links Data Sheet 720115 Page 2 of 9 ## Cylindrical Fuse Links for Industrial Applications Class gG/gL, 0.5 to 125A, 400 to 690Vac ## Class gG/gL - Time-Current Characteristics **==> picture [294 x 267] intentionally omitted <==** **----- Start of picture text -----**<br> > EOI<br>of ETI ACCT AANA<br>© EEE EH<br>2 A<br>rer A NNN TART<br>2 tt OA ARAL<br>BBS 8 5 ee eee a ee ee A'S SE<br>o2 HILLNNECACN NILE<br>2<br>568, 2 34568,. 2 34568,,<br>10' 10 10<br>Prospective Current (RMS A)<br>(s)<br>Time<br>Pre-Arcing<br>**----- End of picture text -----**<br> 04-06-09 SB-SB09488 Form No Cylindrical Fuse Links Page 3 of 9 Data Sheet 720115 ## Bussmann |<i Cylindrical Fuse Links for Industrial Applications Class gG/gL, 0.5 to 125A, 400 to 690Vac ## Class gG/gL - Cut-off Characteristics **==> picture [254 x 373] intentionally omitted <==** **----- Start of picture text -----**<br> IN |)Ra<br>8 ot<br>es ee ee ee = i<br>6 po ee<br>oe a<br>4 es<br>a<br>+e || | | VARAe<br>9} a Se<br>ee a a ee ee =<br>6 a 8 = a ee = OS — a<br>5 |Tereesoe<br>o | Aer<br>> | Zeer<br>er<br>ee<br>3 a}>—— ee SS| ee<br>Sas SS<br>6 — | 1 eer<br>5 ee Be) =e ee<br>fe a |<br>‘ a a a<br>Sel<br>40° 410° 3456 8<br>Prospective Current (RMS kA)<br>Peak)<br>(kA<br>Current<br>of<br>Value<br>Maximum<br>**----- End of picture text -----**<br> 04-06-09 SB-SB09488 Form No Cylindrical Fuse Links Page 4 of 9 Data Sheet 720115 ## Cylindrical Fuse Links for Industrial Applications Class gG/gL, 0.5 to 125A, 400 to 690Vac **==> picture [492 x 339] intentionally omitted <==** **----- Start of picture text -----**<br> Class gG/gL - I [2] t Values Class gG/gL - Watts Loss Values<br>5 ee oe<br>Size mm<br>Amp<br>——— ESSE Eee -— 8x31 10x38 14x51 22x58<br>_——— — -<br>————————SS 0.5 1.2 1.43<br>1 2.0 2.77 3.90<br>2 0.5 0.60 0.90 1.00<br>4 0.8 0.70 1.00 1.10<br>Sr_———SS Be 1068 1.11.31.0 0.850.751.00 1.151.001.30 1.301.101.50<br>12 1.2 1.30 1.70 1.80<br>a=e Se A a a ee (( 16 1.5 1.60 2.00 2.10<br>20 2.0 2.00 2.50 2.70<br>25 2.6 2.60 3.30 3.30<br>32 2.90 3.50 3.50<br>40 4.75 4.00<br>50 4.80 5.50<br>es ee 0<br>10, ce ce cee ee Ge ee ee ees coed el 6380 6.907.80<br>es ee ee er ee ee es er<br>100 9.00<br>———a ee<br>125 11.40<br>SSS — a<br>A, =ae, eS e ee rrreee<br>——— I ——————<br>—<br>CE<br>3<br>aa<br>ee<br>10° hPa heen ease<br>05 12 4 6 8 10 12 16 20 25 32 40 50 63 80 10 125<br>Rated Current (A)<br>2s)(A<br>Value<br>2It<br>**----- End of picture text -----**<br> **==> picture [186 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> Class gG/gL - Watts Loss Values<br>**----- End of picture text -----**<br> 04-06-09 SB-SB09488 Form No Cylindrical Fuse Links Data Sheet 720115 Page 5 of 9 ## Cylindrical Fuse Links for Industrial Applications Class aM, 0.16 to 125A, 400 to 690Vac ## Class aM - Catalogue Numbers |Size (mm)|Current (A)|Catalogue Numbers<br>Without Indicator|Catalogue Numbers<br>With Indicator|Catalogue Numbers<br>With Striker|Voltage (V)|Breaking Capacity<br>(kA)| |---|---|---|---|---|---|---| |8x31|1|C08M1|-|-|400V|20kA| ||2|C08M2|-|-||| ||4|C08M4|-|-||| ||6|C08M6|-|-||| ||8|C08M8|-|-||| |10x38|0.16|C10M0.16|-|-|500V|120kA| ||0.25|C10M0.25|-|-||| ||0.5|C10M0.5|-|-||| ||1|C10M1|C10M1I|-||| ||2|C10M2|C10M2I|-||| ||4|C10M4|C10M4I|-||| ||6|C10M6|C10M6I|-||| ||8|C10M8|C10M8I|-||| ||10|C10M10|C10M10I|-||| ||12|C10M12|C10M12I|-||| ||16|C10M16|C10M16I|-||| ||20|C10M20|C10M20I|-|400V|| ||25|C10M25|C10M25I|-||| |14x51|0.25|C14M0.25|-|-|500V|120kA| ||0.5|C14M0.5|-|-||| ||1|C14M1|C14M1I|-||| ||2|C14M2|C14M2I|C14M2S||| ||4|C14M4|C14M4I|C14M4S||| ||6|C14M6|C14M6I|C14M6S||| ||8|C14M8|C14M8I|C14M8S||| ||10|C14M10|C14M10I|C14M10S||| ||12|C14M12|C14M12I|C14M12S||| ||16|C14M16|C14M16I|C14M16S||| ||20|C14M20|C14M20I|C14M20S||| ||25|C14M25|C14M25I|C14M25S||| ||32|C14M32|C14M32I|C14M32S||| ||40|C14M40|C14M40I|C14M40S||| ||50|C14M50|C14M50I|C14M50S|400V|| |22x58|2|C22M2|C22M2I|-|690V|80kA| ||4|C22M4|C22M4I|||| ||6|C22M6|C22M6I|||| ||8|C22M8|C22M8I|||| ||10|C22M10|C22M10I|||| ||12|C22M12|C22M12I|C22M12S||| ||16|C22M16|C22M16I|C22M16S||| ||20|C22M20|C22M20I|C22M20S||| ||25|C22M25|C22M25I|C22M25S||| ||32|C22M32|C22M32I|C22M32S||| ||40|C22M40|C22M40I|C22M40S||| ||50|C22M50|C22M50I|C22M50S||| ||63|C22M63|C22M63I|C22M63S||| ||80|C22M80|C22M80I|C22M80S|500V|120kA| ||100|C22M100|C22M100I|C22M100S||| ||125|C22M125|C22M125I|C22M-125S|400V|| 04-06-09 SB-SB09488 Form No Cylindrical Fuse Links Data Sheet 720115 Page 6 of 9 ## Cylindrical Fuse Links for Industrial Applications Class aM, 0.16 to 125A, 400 to 690Vac ## Class aM - Time-Current Characteristics **==> picture [10 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> (s)<br>Pre-Arcing Time<br>**----- End of picture text -----**<br> Prospective Current (RMS A) 04-06-09 SB-SB09488 Form No Cylindrical Fuse Links Data Sheet 720115 Page 7 of 9 ## Cylindrical Fuse Links for Industrial Applications Class aM, 0.16 to 125A, 400 to 690Vac **==> picture [333 x 499] intentionally omitted <==** **----- Start of picture text -----**<br> Class aM - Cut-Off Characteristics<br>Ic (kA)<br>——rE————S,<br> ee<br>8 [ieee] [eee] [eee] EE Eee are ee ee nn<br>rr ee a) ee ee 2 ee ee<br>6 a ee ee ee<br>5 ee ee 2 ee ee ee<br>ar el ee i ee<br>‘ a<br>TT<br>5SS SD de el<br>8 eeeeee) ae A eee ee<br>orer<br>6 ee ee =<br>5 ee ee ee a as<br>4 a se a a<br>a N28rl 2 as<br>ge<br>f i<br>1 i<br>eS a a<br>aaa a ae ee aes ee ee ee ee SS Ss =<br>6 ee a os ee ee ee<br>5 | ee ee<br>4 |_ A-Aate t teettt T<br>|Z Teer TTT<br>EATer<br>2 TF | | pe aati<br>(345640" 8 40° 345645 Bo 2<br>Prospective Current (RMS kA)<br>(kA Peak)<br>Current<br>of<br>Value<br>Maximum<br>**----- End of picture text -----**<br> 04-06-09 SB-SB09488 Form No Cylindrical Fuse Links Page 8 of 9 Data Sheet 720115 ## Cylindrical Fuse Links for Industrial Applications Class aM, 0.16 to 125A, 400 to 690Vac ## Class aM - I[2] t Values ## Class aM - Watts Loss Values ||3<br>9|=|=<br>=<br>=|ee|ee|ee<br>a<br>-|Amp|8x31|Size mm<br>10x38|Size mm<br>14x51|22x58| |---|---|---|---|---|---|---|---|---|---|---|---| ||||||||0.16||0.24||| ||||||||0.25||0.36|0.41|| ||||||||0.5||0.49|0.69|| ||3(¢——______<br>=|||||===|1|0.10|0.10|0.14|| ||||||||2|0.16|0.18|0.24|0.29| |||||||a<br>-—|4<br>6<br>8|0.25<br>0.35<br>0.40|0.31<br>0.32<br>0.52|0.45<br>0.42<br>0.70|0.48<br>0.47<br>0.73| ||:<br>to —_—_———_________<br>aes|||ai<br> |||scence<br>i hol<br>a|10<br>12<br>16<br>20|0.65|0.55<br>0.63<br>0.92<br>0.96|0.53<br>0.88<br>1.16<br>1.23|0.74<br>0.83<br>1.21<br>1.29| ||||||||25||1.40|1.46|1.53| |I2t Value (A2s)||||||||| ||32<br>40<br>45<br>50|||2.04<br>2.60<br>2.85<br>2.90|2.13<br>3.40<br>3.48| ||8||ee||||63<br>80||||4.46<br>5.86| ||||||||100||||6.61| ||10<br>—|ee<br>oo<br>ha<br>stetl<br>SaaS SSSS SSS SS SS|||||125||||8.42| ||aif||ie a ee ee<br>12<br>4<br>6<br>8<br>10<br>12||16|ie<br>|<br>20<br>25<br>32<br>40 50<br>63<br>80 100 125|||||| ||w <br>a||Rated Current (A)<br> |OperatingIt<br>400<br>PreareingI"t||||||||| 04-06-09 SB-SB09488 Form No Cylindrical Fuse Links Data Sheet 720115 Page 9 of 9
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →