BM2R08MV1
Time Delay Relay, 0.5 s, 10 Days, Syrline BA2R Series, DPDT, 8 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET
- Product type: Time Delay Relays - Electromechanical
- Contact Voltage VDC:-; Time Min:0.5s; Time Max:10Days; Product Range:Syrline Series; Contact Configuration:DPDT; Contact Current:8A; Relay Mounting:DIN Rail; Contact Voltage VAC:
- SVHC: No SVHC (21-Jan-2025)
- Time Max: 10Days
- Time Min: 0.5s
- Product Range: Syrline BA2R Series
- Relay Mounting: DIN Rail
- Contact Current: 8A
- Relay Terminals: Screw
- Nom Input Voltage: 240VAC
- Timing Adjustment: Knob
- Contact Voltage VAC: 250V
- Contact Voltage VDC: -
- Approvals & Standards: CCC, CE, cULus
- Contact Configuration: DPDT
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 92.53 € |
| Current stock | 50+ |
| Lead time | 30 days |
## **BM2R** Timers Syrline 17.5 mm - 2 Relay 8A - › Multi Multi ~~-~~ function or mono function or mono- ~~f -~~ function unction › Multi . ~~-~~ range (12 function) hs › Multi MultiMulti ~~-~~ - ~~-~~ voltage 12 →240 V AC/DC voltagerange (1212 function)-240 V AC/DC › LED status indicator (relay version) LED status indicator (relay version) - ›› Possibility of external load connection in parallel to the control input3 control3Possibility- ~~-~~ wire PNP sensor compatible wire PNPinput of sensor external compatible load connection in parallel to the |Specifications|Specifications||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Functions||Delay||Output|Nominal rating|||||Connections||Supply voltage|||Code| |A - Ac - At - B - C - D - Di -||0,5 s →10 days|0,5 s →10 days|2 changeover|2 x 8 A||2 x 8 A|||Screw terminals||12 →240 V ∿/⎓|||BM2R08MV1| |H - Ht -N - TL - Tt||||relays|||||||||||| ||||||||||||||||| |Output relay|||||||||||||||| |Contact arrangement||||||2 CO (SPDT) (ChangeOver -Simple Pole Double Throw-)|||||2 CO (SPDT) (ChangeOver -Simple Pole Double Throw-)|||2 CO (SPDT) (ChangeOver -Simple Pole Double Throw-)|| |||||||R1: Follow timing function|R1: Follow timing function||||||||| |||||||R2: Follow timing function / Instantaneous|R2: Follow timing function / Instantaneous||||||||| |Maximum switching voltage||||||250 VAC/ 8 A resistive / 250 VDC / 0.3 A resistive|||||||||| |Switching current rate (resistive)||||||NO / NC : 8A 250 V AC / 8 A 30 VDC @ 25°C|||NO / NC : 8A 250 V AC / 8 A 30 VDC @ 25°C||||||| |||||||NO / NC : 5A 250 V AC / 5 A 30 VDC @ 60°C|||NO / NC : 5A 250 V AC / 5 A 30 VDC @ 60°C||||||| |Minimum switching contact||||||10 mA / 5 VDC|||10 mA / 5 VDC||||||| |Maximum switching power (resistive)||||||2000 VA / 80 W @ 25°C|||2000 VA / 80 W @ 25°C|2000 VA / 80 W @ 25°C|||||| |Electrical life||||||105cycles min at 250 VAC/ 8 A resistive|||cycles min at 250 VAC/ 8 A resistive||||||| |Maximum rate (at max switching power)||||||360 cycles /hour|||||||||| |Mechanical life||||||10 x 106cycles|||||||||| |Rated impulse voltage||||||5 kV (1.2/50µs)|||||||||| |Dielectric strength between coil / contacts|||Dielectric strength between coil / contacts|||IEC 60664-1: 5 kV /1 min / 1 mA / 50 Hz|||||||||| |Dielectric strength between open contacts|||Dielectric strength between open contacts|||2.5 kV /1 min / 1 mA / 50 Hz|2.5 kV /1 min / 1 mA / 50 Hz||||||||| ||||||||||||||||| |Timing|||||||||||||||| |Timing ranges (7 ranges)||||||0.5→10s, 0.05→1min, 0.5→10min, 0.05→1h, 0.5→10h, 0.05→1day,|||||||||| |||||||0.5→10days|||||||||| |Minimum pulse duration typically (relay version)|||Minimum pulse duration typically (relay version)|||IEC 1812-1: 30 ms|||||||||| |||||||100 ms with load|||||||||| |Maximum reset time by de-energisation typically (relay version)||||||IEC 1812-1: 120 ms||||IEC 1812-1: 120 ms|||||| |Repeatability||||||IEC 1812-1: ≤ ± 0,5 %||||IEC 1812-1: ≤ ± 0,5 %|||||| |Repetition accuracy with constant parameters||||||IEC 1812-1: ≤ ± 10 %||||IEC 1812-1: ≤ ± 10 %|||||| |Drift Temperature||||||≤ ± 0.05 % / °C|||||||||| |Voltage-dependent drift||||||≤ ± 0.2 % / V|||≤ ± 0.2 % / V||||||| **I** Timers **I 02** **I** www.crouzet-control.com |Supply|Supply| |---|---| |Multi-voltage power supply|12→240 V∿/⎓| |Operating range|15 %, +10 %| |Operating frequency (Hz)|50 / 60 Hz ± 5 %| |Galvanic isolation|No| |Max. absorbed power|Approx. 3 VA (V∿) 1.5 W (V⎓)| |Immunity from micro power cuts|10 ms| ||| |General characteristics|| |Insulation voltage, IEC 60664-1|300 V| |Installation category (acc. to IEC/EN 60664-1)|Overvoltage category III ; pollution degree 2| |Impulse voltage CEI/EN 60664-1|4 kV (1,2 / 50 µs)| |Clearance / Creepage distances|IEC 60664-1: 3 mm / 3.2 mm| |Breakdown voltage|EN-61812-1: 2,5 kV / 1 min / 1 mA / 50 Hz| |Insulation resistance|NFC 93 050: > 500 MΩ / 250 V⎓ / 1min| |Status indication|Un: green LED blinks when count, continuous ON when supplied<br>R: yellow LED continuous ON when the relay is ON| |Casing|DIN 43880: 17,5 mm| |Fixing: Symmetrical DIN rail|EN 50022: 35 mm| |Mounting position|All positions| |Housing material|Enclosure plastic type UL94 - V0| |Protection (IEC/EN 60529)|Housing: IP40 / Terminal block: IP20| |Terminal capacity Single-wire without ferrule|IEC 60947-1<br>1 x 0.5 →3.3 mm² (AWG 20 →AWG 12)<br>2 x 0.5 →1.5 mm² (AWG 20 →AWG 16)| |Max. tightening torque (Nm)|IEC 60947-1: 0,5 N.m / 4,4 lbf.in| |Operating temperature range (°C)|IEC 60068-2: -20 °C →+60 °C| |Storage temperature range (°C)|IEC 60068-2: -40 °C →+70 °C| |Relative humidity no condensation acc. to IEC/EN 60068-2-30|93 % without condensation| |Vibration resistance according to IEC/EN 60068-2-6|± 0.15 mm from 10 Hz →60 Hz 2g from 60 Hz →150 Hz| |Impact resistance|IEC 60068-2-27<br>15gn - 11ms ; 3 x 6 axis (output OFF)<br>5gn - 11ms ; 3 x 6 axis (Output ON)| |Drop to concrete floor|IEC 60068-2-32<br>High: 0.75m| |Weight: casing 17,5 mm|70 g<br>80 g with packaging| |Directives|2014/30/EU: EMC<br>2014/35/EU: low voltage| |Certifications|CE - cULus Listed Industrial Control Equipment - CCC| |Conformity to standards|CEI 60664-1: Insulation coordination for equipment within low-voltage<br>systems<br>CEI 61812-1/ Specified time relays for industrial use<br>UL 60947-4-1/ Industrial Control Equipment (NRNT- Industrial Control<br>Switches)| |Conformity with environmental directives|2015/863/UE: RoHS<br>1907/2006: Reach<br>2012/19/UE: WEEE| |Electromagnetic compatibility IEC 61000-6-2, IEC 61000-6-3,<br>IEC 61000-6-4|Immunity for industrial environment<br>Emission residential environment<br>Emission industrial environment| |Electromagnetic compatibility - Immunity to electrostatic discharges<br>acc to IEC/EN 61000-4-2|Level III Air ± 8 KV / Contact ± 6 KV| **I** Timers **I 03** **I** www.crouzet-control.com ## General characteristics |General characteristics|General characteristics| |---|---| |Immunity to radiated, radio-frequency, electromagnetic field acc.<br>IEC/EN 61000-4-3|Level III<br>10 V/m (80 M Hz to 1 G Hz) 80 % AM (1 k Hz)<br>3 V/m (1,4 →2 G Hz) 80 % AM (1K Hz)<br>1V/m (2 →2.7 G Hz) 80 % AM (1K Hz)| |Immunity to rapid transient bursts acc. to IEC/EN 61000-4-4|Level III direct ± 2 kV (power supply) / capacitive coupling clamp<br>± 1 KV (command input and outputs)| |Immunity to shock waves on power supply acc. to IEC/EN 61000-4-5|Level III<br>line-to-earth ± 2 kV / line-to-line ± 1kV| |Immunity to radio frequency in common mode acc. to<br>IEC/EN 61000-4-6|Level III<br>10 Vrms (0,15 →80 M Hz) 80 % AM (1 k Hz)| |Immunity to voltage dips and breaks acc. to IEC/EN 61000-4-11|Industrial Class II:<br>0 % residual voltage during 1cycle a.c. power ports<br>70 % residual voltage during 25/30 cycles a.c. power ports<br>0 % residual voltage, 250/300 cycles a.c. power ports<br>Residential:<br>0 % residual voltage during 10 cycle a.c.power ports<br>40 % residual voltage during 10 cycles a.c. power ports<br>70 % residual voltage during 10 cycles a.c. power ports<br>0 % residual voltage, 250/300 cycles a.c. power ports| |Mains-borne and radiated emissions acc. to EN 55022 (CISPR22),<br>EN55011 (CISPR11)|EN 55022 / CISPR22 Class B (IT equipment)<br>EN 55011 / CISPR11 Class B, Group 1 (Medical equipment)| |Curves|Curves| |---|---| |Function A Delay on energisation<br>R1: Follow timing function<br>R2: Follow timing function / Instantaneous|U<br>R2<br>R1/R2<br>T| |Function Ac Timing after closing and opening of control contact<br>R1: Follow timing function<br>R2: Follow timing function / Instantaneous|U<br>Y1<br>R1/R2<br>T<br>T<br>R2 inst.| |Function At Timing on energisation with memory<br>R1: Follow timing function<br>R2: Follow timing function / Instantaneous|U<br>Y1<br>R1/R2<br>t1<br>t2<br>~~T = t1+t2~~| |Function B Timing on impulse one shot<br>R1: Follow timing function<br>R2: Follow timing function / Instantaneous|~~T = t1+t2~~<br>U<br>R2<br>Y1<br>R1/R2<br>∞<br>T| |Function C Timing after impulse<br>R1: Follow timing function<br>R2: Follow timing function / Instantaneous|U<br>2R<br>Y1<br>R1/R2<br>∞<br>T| **I** Timers **I 04** **I** www.crouzet-control.com |Curves|Curves| |---|---| |Function D Flip-flop Pause start<br>R1: Follow timing function<br>R2: Follow timing function / Instantaneous|U<br>R2<br>T T<br>R1/R2| |Function Di Flip-flop Pulse start<br>R1: Follow timing function<br>R2: Follow timing function / Instantaneous|U<br>R2<br>T<br>Y1<br>R1/R2<br>T| |Function H Timing on energisation<br>R1: Follow timing function<br>R2: Follow timing function / Instantaneous|T<br>R1/R2<br>U<br>R2| |Function Ht Delay on energisation with memory<br>R1: Follow timing function<br>R2: Follow timing function / Instantaneous|t1<br>R1/R2<br>Y1<br>U<br>R2<br>t2<br>T = t1+t2| |Function N Watchdog<br>R1: Follow timing function<br>R2: Follow timing function / Instantaneous|T<br>R1/R2<br>Y1<br>U<br>R2<br>∞<br>T| |Function TL Impulse relay<br>R1: Follow timing function<br>R2: Follow timing function|8<br>8<br>8<br>U<br>Y1<br>R1/R2|
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →