Image not available
Illustrative purposes only
BK/MDM-1
SMD FUSES WITH CLIPS - HOLDERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON / PARTNER STOCK
- Product type: SMD Fuses
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 18 |
| Price | 16.84 € |
| Current stock | 500+ |
| Lead time | 30 days |
**Bussmann electrical full line catalog**
## **Protection**
Le Se ei NS Rr - i il ae 4 “ar ia { Hl i i **Introducing Bussmann by Eaton** 7 The protection you rely on. For more, visit Bussmann.com < aR ea eggs tTee et aI re ee hee Say Se eee
## Leadership in Circuit Protection.
## The only company that can provide a complete circuit protection solution for all applications.
## **Only Eaton can deliver...**
- The most diverse solutions to mitigate arc flash energy to keep people and equipment safe
- The smallest and most cost effective way to meet selective coordination requirements
- The most experienced, time-tested solutions to meet national & local code requirements
- The easiest specifications with the most tested fuse/circuit breaker and circuit breaker/circuit breaker series rated combinations
> • The only one-stop shop to solve your design challenges using our expertise and an unmatched portfolio
## The Eaton advantage.
## Powering business worldwide
As a global diversified power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses.
Eaton’s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, efficiently, safely and sustainably.
We provide integrated solutions that help make energy, in all its forms, more practical and accessible.
With 2012 sales of $16.3 billion, Eaton has approximately 103,000 employees around the world and sells products in more than 175 countries.
**Eaton.com**
## **Introducing Fuses Made Simple[™]**
**3**
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**Alternative Energy Vertical Market**
**==> picture [495 x 320] intentionally omitted <==**
**----- Start of picture text -----**<br>
56 63 289<br>PVM Midget XL Photovoltaic Modular<br>& PV Fuses o Fuses and Blocks Knifeblade<br>= Fuse Blocks<br>~y +<br>57 121 325<br>CUBEFuse™ Square Body, Power<br>PVCF & WCF BS and UL Distribution<br>High Speed Fuses Blocks<br>59 266 442<br>PVS-R RK5 Quik-Spec™ Surge Protection<br>PV Fuses Coordination Solutions<br>Photovoltaic and Wind<br>Panelboard<br>60<br>270<br>Ferrule<br>Photovoltaic A ibd Safety Switches<br>Fuses AC & DC<br>62 ae 274 eee<br>= wate<br>NH Fuses & Modular Fuse<br>Fuse Blocks Holders<br>**----- End of picture text -----**<br>
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**4**
**Data Centers Vertical Market**
¢ Circuit
_23_ Low-Peak™ CC Fuses _28_ CUBEFuse™ TCF & FCF _121_ Square Body, BS and UL High Speed Fuses
_125_ DFJ High Speed Fuses _266_ Quik-Spec™ Coordination Panelboard _325_ Power Distribution Blocks
_333_ DIN-Rail Terminal Blocks and Connectors
_380_ Compact Circuit Protectors _441_ Surge Protection Solutions – UL, IEC and LV
**5**
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**Oil & Gas/ Mining Vertical Market**
**==> picture [234 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
A Complete Line of u ro MANU Uae Circuit a<br>**----- End of picture text -----**<br>
**==> picture [455 x 331] intentionally omitted <==**
**----- Start of picture text -----**<br>
23 im 121 327<br>Low-Peak™ Square Body, Power<br>Fuses BS and UL Distribution<br>ion High Speed Fuses i Blocks<br>26 125 380<br>CUBEFuse™ DFJ Compact Circuit<br>TCF & FCF — ae High Speed ea Protectors<br>Fuses ty<br>. |<br>46 266 441<br>Fusetron™ Energy oo | Quik-Spec™ t 4. Surge Protection<br>Efficient Fuses Coordination Solutions<br>Panelboard – UL, IEC and LV<br>62 274<br>NH Fuses & (Pes Modular Fuse ae<br>Fuse Blocks Holders Ss @ o lw<br>99 289<br>Medium Modular<br>Voltage Fuses Knifeblade<br>Fuse Blocks<br>**----- End of picture text -----**<br>
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**6**
**Circuit Protection Products for the Electrical Industry**
## **Table of Contents**
**RED indicates NEW information**
Vertical Market Product Pages . . . . . . . . . . . . .4-6 Alternative energy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Data centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Oil & gas / mining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Peel and Stick Tabs . . . . . . . . . . . . . . . . . . . . . .11 Selecting Circuit Protection . . . . . . . . . . . . . .12-16 2011 NEC[®] guide to fuse selection for various applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-16 Low Voltage, Branch Circuit Rated Fuses . . .17-52 Holders & blocks for branch circuit rated fuses . . . . . . .18-20 Dimensions data for branch circuit rated fuses . . . . . . .21-22 Class CC LP-CC Low-Peak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 FNQ-R CC-Tron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 KTK-R Limitron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Class CF TCF, FCF & WCF CUBEFuse . . . . . . . . . . . . . . . . . . . . .26-31 CUBEFuse finger-safe holder system . . . . . . . . . . . . . . .32-33 Class G SC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Class J LPJ-_SP & LPJ-_SPI Low-Peak . . . . . . . . . . . . . . . . . . . . .35 JKS Limitron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 Class K5 & H NON (250V) & NOS (600V) One time . . . . . . . . . . . . . . . . .37 Class L KRP-C_SP Low-Peak . . . . . . . . . . . . . . . . . . . . . . . . . .38-39 KRP-CL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 KTU & KLU Limitron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Class RK1 LPN-RK_SP & LPN-RK_SPI (250V) Low-Peak . . . . . . . .41-43 LPS-RK_SP & LPS-RK_SPI (600V) Low-Peak . . . . . . . .41-43 KTN-R (250V) Limitron . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 KTS-R (600V) Limitron . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Class RK5 FRN-R (250V) Fusetron (Energy Efficient) . . . . . . . . . . . . . .46 FRS-R (600V) Fusetron (Energy Efficient) . . . . . . . . . . . . . .47 Class T JJN (300V) T-Tron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 JJS (600V) T-Tron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Edison & Rejection Base Plug Fuses Plug Fuses (S, SL, T, TL & W) . . . . . . . . . . . . . . . . . . . .50-51 MB Edison Base Circuit Breakers . . . . . . . . . . . . . . . . . . . .52 SA Rejection-base plug fuse adapters . . . . . . . . . . . . . . . .52
Solar Fuse Products . . . . . . . . . . . . . . . . . . .53-70 PVM (600Vdc) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 PVCF (600Vac/300Vdc) . . . . . . . . . . . . . . . . . . . . . . . .57-58 PVS-R (600Vac/dc) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 PV (1000Vdc) 10x38mm . . . . . . . . . . . . . . . . . . . . . . . . . .60 PV (1000/1100Vdc) 14x51mm . . . . . . . . . . . . . . . . . . . . .61 NH1 (1000Vdc) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 XL PV (1000Vdc) XL Size 01, 1, 2, 3 . . . . . . . . . . . . . . .63-65 PV (1300/1500Vdc) 14x65mm . . . . . . . . . . . . . . . . . . . . .66 XL PV (1200/1500Vdc) XL Size 01, 1, 2, 3 . . . . . . . . . .67-69 Low Voltage Supplementary Fuses . . . . . . . .71-84 Holders & blocks for supplemental fuses . . . . . . . . . . . .72-73 Cable (K Series) & Welder (64000/68000 Series) Limiters . .74 13⁄32" x 1 1⁄2" fast-acting fuses BAF, KTK & KLM . . . . . . . . . . .75 13⁄32" x 1 1⁄2" time-delay fuses FNM & FNQ . . . . . . . . . . . . . .76 13⁄32" x 1 3⁄8" fast-acting fuses BBS . . . . . . . . . . . . . . . . . . . .77 Pin indication fuses GBA/GLD, MIC & MIN, FNA, MIS & KAZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78-79 Limiters & blocks ANL & ANN . . . . . . . . . . . . . . . . . . . . . . .79 In-line size rejecting fuses and holders GLQ, GMQ, HLQ . . .80 In-line non-rejecting fuses and holders GLR, GMF, GRF, HLQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81 Automotive blade fuses and holders ATM, ATC, MAX . . .82-83 Automotive PCB fuse clips for ATM & ATC . . . . . . . . . . . . . .84 Electronic - PC Board and Small Dimension Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85-98 5 x 15mm Ferrule fuses C515, C516, C517, C518, C519, C520 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 5 x 20mm European (IEC) fuses S500, S501, S505, S506, GDA, GDB, GDC . . . . . . . .87-88 5 x 20mm North American (UL) fuses GMA, GMC, GMD- . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 1 5 ⁄4" Diameter x ⁄8" to 1" length ferrule fuses AGA, AGW, AGX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90 1 1 ⁄4" Diameter x 1 ⁄4" length fast-acting ferrule fuses ABC, AGC, GBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91 1 1 ⁄4" Diameter x 1 ⁄4" length time-delay ferrule fuses MDA, MDL, MDQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 PC Board mount fuse holders HTC-, HBH-, HBV-, HBW-, FBI, FBM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93-94 PC Board fuseclips HTC-_M, 1A_, 56_ . . . . . . . . . . . . .95-98
Bussmann circuit protection solutions comply with major industrial standards and agency requirements such as: BS, IEC, DIN, UL, NEMA, CSA, CE, C-UL, etc. and are manufactured at facilities that are ISO 9000 certified. This catalog is intended to present product data and provide technical information that will help the end user with design application. Bussmann reserves the right, without notice, to change design or construction or any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this catalog. Once a product has been selected, it should be tested by the user in all possible applications. Further, Bussmann takes no responsibility for errors or omissions contained in this catalog, or for mis-application of any Bussmann product. Extensive product information is available in the Bussmann product data sheets available on line at www.cooperbussmann.com/DatasheetsEle. ©2013 Bussmann
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**7**
**Circuit Protection Products for the Electrical Industry**
## **Table of Contents**
## **RED indicates NEW information**
Medium Voltage Fuses . . . . . . . . . . . . . . . .99-120 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 E-Rated fuses for transformers & feeders . . . . . . . . .101-104 E-Rated fuses: CL-14 & bolt-in . . . . . . . . . . . . . . . . .105-107 E-Rated fuses for potential & small power transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . .108-110 Potential transformer fuses . . . . . . . . . . . . . . . . . . . . . . .111 R-Rated fuses for motor circuit protection . . . . . . . . .112-114 British Standard IEC fuses for motor circuit protection . . .115 DIN IEC fuses for transformers . . . . . . . . . . . . . . . . . . . . .116 Expuision Fuse Links . . . . . . . . . . . . . . . . . . . . . . . .117-118 EEI-NEMA Type K & T, and Type H & N fuses . . . . . . . . . . .119 Fuseclips for medium voltage fuses . . . . . . . . . . . . . . . . .120 High Speed Semiconductor Fuses . . . . . .121-244 General Applications . . . . . . . . . . . . . . . . . . . . . . . . .122-123 North American fuses and accessories DFJ, FWA, FWH, FWJ, FWP, FWX, KAC, KBC, . . . .124-141 Square body fuses and accessories DIN 43 620, DIN 43 653, flush-end contact, French Style, US Style 170E, 170F, 170H, 170M . . . . . . . . . . . .142-213 British BS 88 fuses and accessories CT, ET, EET, FE, FEE, FM, FMM, LCT, LET, LMMT, LMT, MMT, MT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214-222 Ferrule fuses and accessories FWA, FWC, FWH, FWJ, FWK, FWL, FWP, FWS, FWX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223-244 IEC & British Standard Fuses . . . . . . . . . .245-264 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . .245-246 CSA Type P and Type D fuses CDN, CDS, PON . . . . . . . . .247 HRC Form II Class C Tron[™] fuses CGL . . . . . . . . . . . . . . . .248 HRCI Industrial ceramic body fuses CIF . . . . . . . . . . . . . . .249 HRCI-J Fast-acting fuses CJ . . . . . . . . . . . . . . . . . . . . . .250 MRCI-Miscellaneous Type K fuses CIH, CIK, CIL . . . . . . . . .251 HRC Form II Current-limiting fuses H07C, K07C, L09C, L14C, M09C, M14C, P09C, P11C, R11C . . . . . . . . . . .252 BS 88 British Standard low voltage fuses AAO, AC, AD, BAO, BC, BD, CD, CEO, DD, DEO, ED, EF, EFS, ESD, FF, FG, GF, GG, GH, NITD, NSD, OSD, SSD, STD . . . . . .253-254 DIN Type D and Neozed low voltage fuses D16, D27, D33, D125, NZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255 NH HRC Fuse links & bases NHG . . . . . . . . . . . . . . .256-259 Class gG/gL IEC 60 269 fuses C08G, C08M, C10G, C10M, C14G, C14M, C22G, C22M . . . . . . . . . . . . . . . . .260-262 HRC Fuse holders CAMaster, SAFEloc . . . . . . . . . . . . . . . .263
Quik-Spec™ Electrical Gear . . . . . . . . . . .265-272 Quik-Spec™ Coordination Panelboards . . . . . . . . . . .266-267 Quik-Spec™ Power Module™ Elevator Disconnect Switches & Panels PS, PMP . . . . . . . . . . . . . . . . .268-269 Quik-Spec™ DC Safety Switches BD . . . . . . . . . . . . . . . .270 Quik-Spec™ AC Safety Switches CF . . . . . . . . . . . . . . . .271 HVAC Disconnects B221, B222 . . . . . . . . . . . . . . . . . . . .272 Fuse Holders and Blocks . . . . . . . . . . . . . .273-322 CH Series global modular fuse holders - Class CC, midget & metric CHCC, CHPV, CHM, CH08, CH14, CH22 . . . . . . . . .274-277 Remote fuse monitoring - CH-PLCCH . . . . . . . . . . . . . . . .278 Comb-bus bar specifications and selection guide . . . . . . .279 Comb-bus bar features and installation guide . . . . . . . . . .280 CH Series Class J global modular fuse holders CH . . . . . .281 Optima - fuse holder module and disconnect switch . . . . .282 Optima fuse holder module . . . . . . . . . . . . . . . . . . . . . . .283 Optima NG 3-pole overcurrent protection module . . . .284-285 Safety J Class J (finger-safe) fuse holder JT, JTN . . . .286-287 SAMI™ fuse covers SAMI . . . . . . . . . . . . . . . . . . . . . . . .288 Modular Knifeblade Fuse Holders . . . . . . . . . . . . . . .289-290 Class R, H(K), 250 & 600V . . . . . . . . . . . . . . . . . .291-292 Class J, 600V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293 Class H(K) and R fuse blocks - 250V . . . . . . . . . . . . .294-295 Class H(K) and R fuse blocks - 600V . . . . . . . . . . . . .296-297 Class J fuse blocks J600, JP, JA Add-a-Pole . . . . . . .298-299 Class T fuse blocks - 300V . . . . . . . . . . . . . . . . . . . .300-301 Class T fuse blocks - 600V . . . . . . . . . . . . . . . . . . . .302-303 Add-on fuse blocks BCA, BMA . . . . . . . . . . . . . . . . . . . . .304 Class CC, Type M and Class G fuse blocks BC, BCCM, BG, BM, G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305 Modular fuse blocks BH . . . . . . . . . . . . . . . . . . . . . . . . . .306 Box cover units for plug fuses SCY, SKA, SOU, SOW, SOX, SOY, SRU, SRW, SRX, SRY, SSN, SSU, SSW, SSX, SSY, STY, . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .307 In-line fuse holders HFA, HFB, HHB, HHT, HM, HR, HRK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308-309 Tron[™] in-line fuse holders HEB, HEC, HEG, HEH, HEJ, HET, HEX, HEY, HEZ . . . . . . . . . . . . . . . . . . . . . . . . . . .309-311 Panel mounted fuse holders (including indicating) HJL, HK, HKP, HLD,HPC, HPD, HPF, HPG, HPM, HPS, HPS, HTB, HTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312-318 Fuse blocks for[1] ⁄4" x 1[1] ⁄4" and[1] ⁄4" x 1" fuses . . . . . . .319-320 Fuse blocks for[13] ⁄32" x 1[1] ⁄2" fuses . . . . . . . . . . . . . . . . . . .321 Rail mount fuse blocks & holders . . . . . . . . . . . . . . . . . . .322
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**8**
**Circuit Protection Products for the Electrical Industry**
## **Table of Contents**
## **RED indicates NEW information**
## Power Distribution Blocks . . . . . . . . . . . . .323-332
Power Distribution Block Selection Chart . . . . . . . . . . . . . .324 PDBFS Series finger-safe power distribution blocks . . . . .325 PDB Series power distribution blocks . . . . . . . . . . . . . . . .326 163 Series power terminal blocks . . . . . . . . . . . . . . .327-328 Series 11675 & 11725 power terminal blocks . . . . . . . . .329 Series 160, 162, 163 & 165 power terminal blocks . . . . .329 Series 162, 163 & 165 power stud terminal blocks . . . . . .330 Series 160, 162, 163 & 165 power splicer terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .330 Series 14002 (barrier) & 14004 (dead front) terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .331 Connectors . . . . . . . . . . . . . . . . . . . . . . . .333-378 DIN-Rail Feed through blocks (DS series) . . . . . . . . . . . . . . . . . . . .334 Feed through blocks (DP series) . . . . . . . . . . . . . . . .335-336 Mini feed through blocks (DM series) . . . . . . . . . . . . . . . .337 Double level blocks (DDP series) . . . . . . . . . . . . . . . . . . . .338 Disconnect blocks (DG series) . . . . . . . . . . . . . . . . . .339-340 Fuse holder blocks (F520 series) . . . . . . . . . . . . . . . .341-342 Internally jumpered blocks (DDNS series) . . . . . . . . . . . . .343 Test blocks (DTST2 series) . . . . . . . . . . . . . . . . . . . . . . . .343 Panel mount blocks . . . . . . . . . . . . . . . . . . . . . . . . .344-345 Short-Circuit Current Ratings (SCCRs) . . . . . . . . . . . .346-347 Top screw-on bridges . . . . . . . . . . . . . . . . . . . . . . . . . . .348 End brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349 Partition plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349 Jumper slides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .350 Top insertion bridges . . . . . . . . . . . . . . . . . . . . . . . . . . . .350 Side insertion bridges . . . . . . . . . . . . . . . . . . . . . . . .351-352 Mounting rails and brackets . . . . . . . . . . . . . . . . . . . . . . .353 Marking system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .354 Marking labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355-357 Feed through blocks (NDN series) . . . . . . . . . . . . . . .358-359 Feed through blocks (C-Rail series) . . . . . . . . . . . . . .360-361 Depluggable blocks . . . . . . . . . . . . . . . . . . . . . . . . .362-363 Multi-pole panel mount blocks . . . . . . . . . . . . . . . . . . . . .364 Quick connect blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . .365 Panel Mount Series TB100 2- to 36-Pole blocks . . . . . . . . . . . . . .366-367 Series TB200 & TB200HB 2- to 30-Pole blocks . . . . .368-369 Series TB300 & TB345 2- to 24-Pole blocks . . . . . . .370-371 Marking options and covers for double row series . . . . . . .372 Top & bottom marking strips for terminal blocks . . . . . . . .373 Series TB400 2- to 12-Pole blocks . . . . . . . . . . . . . . . . . .374 Series KU 2- to 12-Pole panel mount blocks . . . . . . . . . . .375 Series C7021 1- to 6-Pole block . . . . . . . . . . . . . . . . . . .376 Series C7024 1- to 12-Pole block . . . . . . . . . . . . . . . . . .377
Disconnects . . . . . . . . . . . . . . . . . . . . . . . .379-424 Compact Circuit Protector (CCP) disconnect switches 30A Class CC, Midget & 10x38 . . . . . . . . . . . . . . . . . . 380-381 30A 60A and 100A Class CF . . . . . . . . . . . . . . . . . . . . 382-383 CCPB - Compact Circuit Protector Base . . . . . . . . . . . . 384-385 UL 98 fused disconnect switches 30 to 800A Introduction & Agency Information . . . . . . . . . . . . . . . . . . . . 386 Product Line Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387 30A Compact Class CC & Class J . . . . . . . . . . . . . . . . 388-389 30A Class J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390-391 60A Compact Class J . . . . . . . . . . . . . . . . . . . . . . . . . 392-393 60A Class J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394-395 100A Class J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396-397 200A & 400A Class J . . . . . . . . . . . . . . . . . . . . . . . . . 398-400 600A Class J and 800A Class L. . . . . . . . . . . . . . . . . . 402-403 UL 98 non-fused disconnect switches 30 to 1200A Introduction & Agency Information . . . . . . . . . . . . . . . . . . . . 404 Product Line Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405 30A, 60A and 100A Compact . . . . . . . . . . . . . . . . . . . 406-407 100A, 200A and 400A Standard . . . . . . . . . . . . . . . . . 408-409 600A, 800A, 1000A and 1200A Standard . . . . . . . . . . 410-411 UL 508 non-fused disconnect switches 16 to 80A Introduction and Agency Information . . . . . . . . . . . . . . . . . . 412 Product Line Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413 16A, 25A, 40A, 63A and 80A Standard . . . . . . . . . . . . 414-416 Enclosed UL 98 & UL 508 disconnect switches Introduction & Agency Information . . . . . . . . . . . . . . . . . . . . 417 Fused UL 98 30A to 800A Enclosed Disconnects . . . . . . . . . . . . . . . 418-419 Non-Fused UL 98 30 to 1200A Enclosed Disconnects . . . . . . . . . . . . . . . 420-421 Non-Fused UL 508 16 to 80A Enclosed Disconnects . . . . . . . . . . . . . . . . . 422-423 Fused, dead front disconnect switches . . . . . . . . . . . . . . . . 424 Telecom Protection Devices . . . . . . . . . . .425-439 Telpower compact fused disconnect switch . . . . . . . . . . . .426 Telpower miniature fused disconnect switch . . . . . . . . . . .427 Fused disconnect switches for TPA fuses . . . . . . . . .428-429 Fused disconnect switches for TPS fuses . . . . . . . . . . . . .430 Fused disconnect switches . . . . . . . . . . . . . . . . . . . .431-437 Telpower specialty fuses . . . . . . . . . . . . . . . . . . . . . .438-439 Surge Protective Devices (SPD) . . . . . . . .441-460 SurgePOD HEAVY DUTY SPD . . . . . . . . . . . . . . . . . .442-445 SurgePOD PRO SPD . . . . . . . . . . . . . . . . . . . . . . . . .446-448 UL DIN-Rail - High SCCR SPDs 1-Pole, Type 2, BSPM_S2G . . . . . . . . . . . . . . . . . . .449-450 2-Pole, Type 2, BSPM_S3G . . . . . . . . . . . . . . . . . . .451-452
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**9**
**Circuit Protection Products for the Electrical Industry**
## **Table of Contents**
## **RED indicates NEW information**
## Surge Protective Devices (SPD) - (Continued)
3-Pole, Type 2, BSPM_WYG/DLG . . . . . . . . . . . . . . .453-454 4-Pole, Type 2, BSPM_WYNG/HLG . . . . . . . . . . . . . .455-456 UL DIN-Rail - Low Voltage AC/DC Power 1-Pole, Type 2, BSPM_LV . . . . . . . . . . . . . . . . . . . . .457-458 UL DIN-Rail - Low Voltage AC/DC Control 2-Pole, Type 3, BSPH2A_LV . . . . . . . . . . . . . . . . . . .459-460 IEC DIN-Rail - Class I 2-Pole, Class I, BSPS_TN/TT . . . . . . . . . . . . . . . . . .461-462 3-Pole, Class I, BSPS_TNC . . . . . . . . . . . . . . . . . . . .463-464 4-Pole, Class I, BSPS_TNS/TT . . . . . . . . . . . . . . . . .465-466 IEC DIN-Rail - Class II 1-Pole, Class II, BSPM_TN / BSPG_NPE . . . . . . . . . .467-468 2-Pole, Class II, BSPM_TN / BSPH_TT . . . . . . . . . . .469-470 3-Pole, Class II, BSPM_TNC . . . . . . . . . . . . . . . . . . .471-472 4-Pole, Class II, BSPM_TNS / BSPH_TT . . . . . . . . . .473-474 PV DIN-Rail - Lightning Arrester 1-Pole, PV Advance Lightning Arrester / BSPS_PV . . .475-476 PV DIN-Rail - SPDs 2-Module, PV HEAVY DUTY SPD / BSPH2_PV . . . . . .477-478 3-Module, PV HEAVY DUTY SPD / BSPH_YPV . . . . . .479-480 3-Module, PV PRO SPD / BSPP_YPV . . . . . . . . . . . . .481-482 Wind Power DIN-Rail - Class I 1-Pole, Class I, BSPS_WE . . . . . . . . . . . . . . . . . . . .483-484 Wind Power DIN-Rail - Class II 1-Pole, Class II, BSPM_WE / BSPS_WE . . . . . . . . . .485-486 2-Pole, Class II, BSPM_WE / BSPH_WE . . . . . . . . . .487-488 3-Pole, Class II, BSPM_WE . . . . . . . . . . . . . . . . . . . .489-490 4-Pole, Class II, BSPM_WE / BSPH_WE . . . . . . . . . .491-492 UL 4978 Data Signals SPDs . . . . . . . . . . . . . . . . . . . .493-501 SurgePOD™ Series, 150 to 550Vac MCOV . . . . . . . . .502-503 DIN-Rail TVS Series with holder . . . . . . . . . . . . . . . . . . . . .504 Accessories . . . . . . . . . . . . . . . . . . . . . . . .505-512 Bussmann service kits and assortments . . . . . . . . . .506-508 Clip clamps and rail adapters (DIN & American) . . . . . . . . .509 Spare fuse holders, pullers, testers and cabinets . . . . . . . .510 Fuse reducers and dummy "neutrals" . . . . . . . . . . . . . . . .511 Services & Application Guide . . . . . . . . . . . . . .513 Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .514 Custom Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .515 Application Guide . . . . . . . . . . . . . . . . . . . . . . . . . .516-525 Bussmann fuse technology . . . . . . . . . . . . . . . . . . . .516-522 Motor Circuit Branch Circuit Protection . . . . . . . . . . . . . . .523 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .524-526 Out-of-Stock Substitutions/Upgrades . . . . . . . . . . . . . . . .526 Commercial & industrial fuse applications . . . . . . . . . . . . .527 FUSEFinder cross reference . . . . . . . . . . . . . . . . . . . . . . .528 FC[2] Mobile App . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .530 Index by Part Number . . . . . . . . . . . . . . . .532-537 Low-Peak Upgrade . . . . . . . . . . . . . .Inside back cover
||**Catalog Sections**<br>**Page**|
|---|---|
||�**Low Voltage, Branch Circuit Rated Fuses...17**|
||�**Solar Fuse Products.....................................53**|
||�**Low Voltage Supplementary Fuses.............71**|
||�**Electronic - PC Board and Small**|
||**Dimension Fuses ..........................................85**|
||�**Medium Voltage Fuse and Fuse Links ........99**|
||�**High Speed Fuses.......................................121**|
||�**IEC & British Standard Fuses ....................245**|
||�**Quik-Spec™Electrical Gear.......................265**|
||�**Fuse Holders and Blocks...........................273**|
||�**Power Distribution & Terminal Blocks ......323**|
||�**Connectors .................................................333**|
||�**Disconnects................................................379**|
||�**Telecom Protection Devices (SPD)............425**|
||�**Surge Protective Devices...........................441**|
||�**Accessories................................................503**|
||�**Services & Application Guide ....................511**|
||�**Index by Part Number................................532**|
**10** For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
## **PEEL & STICK TABS Circuit Protection Products for the Electrical Industry Mark the products that are important to you.**
**==> picture [514 x 718] intentionally omitted <==**
**----- Start of picture text -----**<br>
Write Your Own<br>Descriptions Here<br>& Blocks & Blocks Index by Index by<br>Branch Circuit Low Voltage Low Voltage Branch Circuit Fuse Holders Fuse Holders Part Number Part Number<br>Products Solar Solar Products Product New New Product<br>& Terminal Blocks Power Distribution Power Distribution & Terminal Blocks<br>New New<br>Low Voltage Low Voltage Connectors Connectors Product Product<br>Supplementary Supplementary<br>New New<br>Product Product<br>Fuses Fuses<br>Electronic Electronic<br>Disconnects Disconnects<br>Fuses Fuses Devices Devices<br>Medium Voltage Medium Voltage Telecom Protection Telecom Protection<br>Fuses Fuses Devices Devices<br>High Speed High Speed<br>Surge Protection Surge Protection<br>IEC & British IEC & British Accessories Accessories<br>Standard Fuses Standard Fuses<br>Services & Services &<br>Quik-Spec™ Quik-Spec™<br>Electrical Gear Electrical Gear Application Guide Application Guide<br>**----- End of picture text -----**<br>
**11**
**Circuit Protection Products for the Electrical Industry**
## **Selecting Circuit Protection**
The following fuse selection guides are based on the 2011 NEC[®] and provided fuse recommendations for the various applications listed.
These are only suggestions. Final fuse selection should be performed only by qualified personnel able to fully assess an application’s circuit protection requirements. If you need assistance in selecting a fuse for a particular application, call
the Cooper Bussmann Application Engineering team for technical and application support Monday – Friday, 8:00 a.m. – 5:00 p.m. Central Time.
Application Engineering can be reached via phone and e-mail:
• Toll-free phone: 855-287-7626 (855-BUSSMANN)
• E-mail: fusetech@cooperindustries.com
## **Ballasts**
**==> picture [523 x 200] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse & Holder Recommendations<br>Indoor Fluorescent Consult fixture manufacturer for size and type. Fuse Holder(s) Fuse Holder(s)<br>GLR HLR GLQ HLQ<br>GMF GMQ<br>GRF<br>Fuse & Holder Recommendations<br>All Other (Mercury,<br>Sodium, etc.) Consult fixture manufacturer for size and type. Fuse Holder(s) Fuse Holder(s) Fuse Holder(s)<br>BAF HPF KTK-R HPS-RR SC 0-15 HPF-EE<br>KTK HPS FNQ-R HPF-RR HPS-EE<br>FNM LP-CC SC 20 HPF-JJ<br>FNQ HPS-JJ<br>KTQ HPS-L SC 25-30 HPF-FF<br>BBS HPF-L HPS-FF<br>Fuse & Holder Recommendations<br>Outdoor Mercury, Sodium, etc. Consult fixture manufacturer for size and type. Fuse Holder(s) Fuse Holder(s)<br>BAF HEB KTK-R HEY<br>KTK HEX FNQ-R<br>FNM HPC-D LP-CC<br>FNQ<br>**----- End of picture text -----**<br>
## **Capacitors (NEC[®] 460)**
|**Protected by**<br>**Time-Delay Fuses.**||~~150% t 175% f Fll Ld Ct~~||**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>0-250<br>LPN-RK_SP, FRN-R<br>0-600<br>LPS-RK_SP, FRS-R<br>LPJ_SP, LP-CC,<br>FNQ-R, TCF|**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>0-250<br>LPN-RK_SP, FRN-R<br>0-600<br>LPS-RK_SP, FRS-R<br>LPJ_SP, LP-CC,<br>FNQ-R, TCF|
|---|---|---|---|---|---|
|||~~o o u oa urren~~||||
|||||||
|**Protected by**<br>**Non-Time-Delay Fuses.**||~~250% t 300% f Fll Ld Ct~~||**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>0-250<br>KTN-R, NON<br>0-300<br>JJN<br>0-600<br>KTS-R, NOS<br>JKS, KTK-R<br>JJS, FCF_RN||
|||~~o o u oa urren.~~||||
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**12**
**Circuit Protection Products for the Electrical Industry**
## **Selecting Circuit Protection**
## **Electric Heat (NEC[®] 424)**
**Electric** ~~**Space Heating**~~ Size at 125% or next size lar60 amps for each subdivided load.ger but in no case larger than **Fuse RecommendationVolts Fuse(s)** 0-250 LPN-RK_SP FRN-R, NON 0-300 JJN 0-480 SC 25 to SC 60 0-600 LPS-RK_SP FRS-R, NOS 0-600 JJS 0-600 LPJ_SP, LP-CC **Electric Boilers with** Size at 125% or next size larger but in no case larger than FNQ-R, JKS, KTK-R, **Resistance Type Immersion** 150 amps for each subdivided load. TCF, SC[1] ⁄2 to SC 20, **Heating Elements in an ASME** FCF_RN **Rated and Stamped Vessel**
## **Mains, Feeders, Branches (NEC[®] 430)**
||||<br>~~N Mt Ld~~<br>~~100% of non-continuous load lus 125% of continuous load~~|<br>~~N Mt Ld~~<br>~~100% of non-continuous load lus 125% of continuous load~~|<br>~~N Mt Ld~~<br>~~100% of non-continuous load lus 125% of continuous load~~|<br>~~N Mt Ld~~<br>~~100% of non-continuous load lus 125% of continuous load~~|<br>~~N Mt Ld~~<br>~~100% of non-continuous load lus 125% of continuous load~~|**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>0-250<br>LPN-RK_SP, FRN-R<br>0-300<br>JJN<br>0-600<br>LPS-RK_SP, FRS-R<br>0-600<br>JJS<br>0-600<br>LPJ_SP, LP-CC<br>JKS, KTK-R, LPT|**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>0-250<br>LPN-RK_SP, FRN-R<br>0-300<br>JJN<br>0-600<br>LPS-RK_SP, FRS-R<br>0-600<br>JJS<br>0-600<br>LPJ_SP, LP-CC<br>JKS, KTK-R, LPT|
|---|---|---|---|---|---|---|---|---|---|
|**Feeder Circuits**<br>**(600A & Less)**||||~~N Mt Ld~~||~~100% of non-continuous load lus 125% of continuous load~~||||
|||||~~o oor oa~~||~~p .~~||||
|||||||||||
|||||||||||
|||||||||**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>0-25O<br>LPN-RK_SP, FRN-R<br>0-600<br>LPS-RK_SP, FRS-R<br>0-600<br>LPJ- SP, LP-CC||
||||~~Mt Ld~~<br>Loads and Other Loads<br>~~, g p~~<br>the sum of all the FLA for all other motors plus 100% of non-<br>continuous, non-motor load plus 125% of continuous, non-<br>motor load.<br>~~150%~~*~~of the FLA of largest motor (if there are two or more~~|||||||
|||||||~~150%~~*~~of the FLA of largest motor (if there are two or more~~||||
||||~~oor oas~~|||<br>motors of same size, one is considered to be the largest) plus<br>the sum of all the FLA for all other motors.||||
||||*A max. of 175% (or the next standard size if 175% does not<br>correspond to a standard size) is allowed for all but wound<br>rotor and all dc motors.|||||||
|**Main, Branch &**<br>**Feeder Circuits**<br>**(601-6000A)**||||||150% to 225% of full load current of largest motorplus 100%||**Fuse Recommendation**<br>**Volts**<br>**Fuse(s)**<br>0-600<br>KRP-C_SP||
|||||||of full load current of all other motors plus 125% of continuous<br>non-motor load plus 100% of non-continuous non-motor load.||||
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**13**
**Circuit Protection Products for the Electrical Industry**
## **Selecting Circuit Protection**
## **Motor Loads (NEC[®] 430)**
**==> picture [523 x 282] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse Sized For:<br>Fuse Recommendations<br>600V & Less Protected by Time- Backup Overload w/ Motor Starter & Short- 125% of motor FLA or next size larger. Volts Fuse(s)<br>Delay Fuses Circuit Protection 0-250 FRN-R<br>0-600 FRS-R<br>Fuse Recommendations<br>130% of motor FLA or next size larger. Volts Fuse(s)<br>0-250 LPN-RK_SP<br>0-600 LPS-RK_SP<br>175%* of motor FLA or next size larger. (If 175% does not<br>Short-Circuit Only correspond to a standard size). If this will not allow motor to Fuse Recommendations<br>start, due to higher than normal inrush currents or longer than<br>Volts Fuse(s)<br>normal acceleration times (5 sec. or greater), fuse may be<br>0-250 LPN-RK_SP, FRN-R<br>sized up to 225% or next size smaller.<br>0-600 LPS-RK_SP, FRS-R<br>LPJ_SP, TCF<br>Protected by Non- Max. of 300%* of motor FLA or next size larger (if 300% does Fuse Recommendations<br>Time Delay Fuses & all Class CC Fuses Short-Circuit Only to start due to higher than normal inrush currents or longernot correspond to a standard size). If this will not allow motor Volts 0-250 KTN-R, NON Fuse(s)<br>than normal acceleration times (5 sec. or greater), fuses 0-300 JJN<br>through 600 amps may be sized up to 400% or next size 0-600 KTS-R, NOS<br>smaller.<br>JJS<br>LP-CC, JKS, KTK-R,<br>*150% for wound rotor and all DC motors. LPT, FCF_RN<br>Above 600V Compare the min. melting time-current characteristics of the fuses with the time-current characteristics of the overload relay Fuse Recommendations Volts Fuse(s)<br>curve. The size fuse which is selected should be such that short.circuit protection is provided by the fuse and overload<br>2400 JCK, JCK-A, JCH<br>protection is provided by the controller overload relays.<br>4800 JCL, JCL-A, JCG<br>7200 JCR, 7.2 WKMSJ<br>**----- End of picture text -----**<br>
## **Solenoids (Coils)**
**Fuse Recommendation Branch Circuit** ~~Size at 125% or next size smaller.~~ **Volts Fuse(s) Fuses** 0-250 Best: LPN-RK_SP FRN-R 0-600 LPS-RK_SP FRS-R 0-600 LPJ_SP, LP-CC FNQ-R, TCF **Supplementary Fuse Recommendation Fuses** ~~Size at 125% or next size larger.~~ **Volts Fuse(s)** 0-32 MDL 9-30A, FNM 20-30A 0-125 MDA 25-30A, FNM 12-15A 0-250 MDL[1] ⁄16-8A, MDA[2] ⁄10-20A, FNM[1] ⁄10-10A, MDQ[1] ⁄100-7A 0-500 FNQ[1] ⁄10-30A
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**14**
**Circuit Protection Products for the Electrical Industry**
## **Selecting Circuit Protection**
## **Transformers 600V Nominal or Less (NEC[®] 450.3)**
**==> picture [523 x 398] intentionally omitted <==**
**----- Start of picture text -----**<br>
Optimum Protection NEC [®] Maximums<br>Note: Components on the secondary still<br>Primary need overcurrent protection Rated primary current less 125% or next size larger Max. 300% or next size smaller (See NEC [®] 430.72(C) for control circuit<br>Protection than 2 amps transformer maximum of 500%<br>Only<br>Rated primary current<br>greater than or equal to 2 125% or next size larger Max. 167% or next size smaller<br>amps but less than 9 amps<br>Rated primary current<br>greater than or equal to 9 125% or next size larger Max. of 125% or next larger*<br>amps<br>Primary and Without Thermal Rated secondary current A A<br>Overload<br>Secondary Protection less than 9 amps<br>Protection Maximum Fuse Size<br>Rated secondary current 9 B B % of Primary FLA<br>amps or greater (or next FLA size smaller)<br>A = 250%<br>B = 250%<br>With Thermal Transformer Rated secondary current C C C = 600%<br>Overload Protection Impedance of 6% or Less less than 9 amps Primary and secondary D = 600% E = 400%<br>fuses at 125% of prima-<br>F = 400%<br>ry and secondary FLA or<br>Rated secondary current 9 D next size larger D % of Secondary FLA<br>amps or greater A = 167% or next size smaller<br>B = 125% or next size larger*<br>Transformer E E C = 167% or next size smaller<br>Impedance of More Than 6% Rated secondary currentless than 9 amps D = 125% or next size larger*E = 167% or next size smaller<br>But Less Than F = 125% or next size larger*<br>10%<br>Rated secondary current 9 F F<br>amps or greater<br>*When 125% of FLA corresponds to<br>a standard rating, the next larger size<br>is not permitted.<br>Fuse Recommendations<br>Volts Fuse(s)<br>**----- End of picture text -----**<br>
**Fuse Recommendations Volts Fuse(s)** 250V LPN-RK_SP, FRN-R 600V KRP-C_SP, LPJ_SP, LPS-RK_SP, FNQ-R, FRS-R, TCF
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**15**
**Circuit Protection Products for the Electrical Industry**
## **Selecting Circuit Protection**
## **Transformers Over 600V Nominal (NEC[®] 450.3)**
|**Supervised**<br>**Installations**|||Primary<br>~~Ptti~~|||Primary at code max. of 250% or<br>~~t tdd i if 250% d t~~|Primary at code max. of 250% or<br>~~t tdd i if 250% d t~~|Primary at code max. of 250% or<br>~~t tdd i if 250% d t~~|Primary at code max. of 250% or<br>~~t tdd i if 250% d t~~|Primary at code max. of 250% or<br>~~t tdd i if 250% d t~~||**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>250V<br>LPN-RK_SP, FRN-R<br>600V<br>LPS-RK_SP, LPJ-_SP,<br>KRP-C_SP, FRS-R, FNQ-R,<br>TCF<br>2475V<br>JCD<br>2750V<br>JCX<br>2750/5500V<br>JCW<br>5500V<br>MV05, 5.5 ABWNA,<br>5.5 AMWNA, 5.5 FFN<br>7200V<br>7.2 AMWNA, 7.2 TDLSJ,<br>~~72 TFLSJ~~<br>Note: Components on the secondary still need<br>overcurrentprotection<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>225%<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary<br>~~600V or~~<br>Below<br>Secondary<br>~~600V or~~<br>Below|**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>250V<br>LPN-RK_SP, FRN-R<br>600V<br>LPS-RK_SP, LPJ-_SP,<br>KRP-C_SP, FRS-R, FNQ-R,<br>TCF<br>2475V<br>JCD<br>2750V<br>JCX<br>2750/5500V<br>JCW<br>5500V<br>MV05, 5.5 ABWNA,<br>5.5 AMWNA, 5.5 FFN<br>7200V<br>7.2 AMWNA, 7.2 TDLSJ,<br>~~72 TFLSJ~~<br>Note: Components on the secondary still need<br>overcurrentprotection<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>225%<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary<br>~~600V or~~<br>Below<br>Secondary<br>~~600V or~~<br>Below|**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>250V<br>LPN-RK_SP, FRN-R<br>600V<br>LPS-RK_SP, LPJ-_SP,<br>KRP-C_SP, FRS-R, FNQ-R,<br>TCF<br>2475V<br>JCD<br>2750V<br>JCX<br>2750/5500V<br>JCW<br>5500V<br>MV05, 5.5 ABWNA,<br>5.5 AMWNA, 5.5 FFN<br>7200V<br>7.2 AMWNA, 7.2 TDLSJ,<br>~~72 TFLSJ~~<br>Note: Components on the secondary still need<br>overcurrentprotection<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>225%<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary<br>~~600V or~~<br>Below<br>Secondary<br>~~600V or~~<br>Below|**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>250V<br>LPN-RK_SP, FRN-R<br>600V<br>LPS-RK_SP, LPJ-_SP,<br>KRP-C_SP, FRS-R, FNQ-R,<br>TCF<br>2475V<br>JCD<br>2750V<br>JCX<br>2750/5500V<br>JCW<br>5500V<br>MV05, 5.5 ABWNA,<br>5.5 AMWNA, 5.5 FFN<br>7200V<br>7.2 AMWNA, 7.2 TDLSJ,<br>~~72 TFLSJ~~<br>Note: Components on the secondary still need<br>overcurrentprotection<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>225%<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary<br>~~600V or~~<br>Below<br>Secondary<br>~~600V or~~<br>Below|**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>250V<br>LPN-RK_SP, FRN-R<br>600V<br>LPS-RK_SP, LPJ-_SP,<br>KRP-C_SP, FRS-R, FNQ-R,<br>TCF<br>2475V<br>JCD<br>2750V<br>JCX<br>2750/5500V<br>JCW<br>5500V<br>MV05, 5.5 ABWNA,<br>5.5 AMWNA, 5.5 FFN<br>7200V<br>7.2 AMWNA, 7.2 TDLSJ,<br>~~72 TFLSJ~~<br>Note: Components on the secondary still need<br>overcurrentprotection<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>225%<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary<br>~~600V or~~<br>Below<br>Secondary<br>~~600V or~~<br>Below|**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>250V<br>LPN-RK_SP, FRN-R<br>600V<br>LPS-RK_SP, LPJ-_SP,<br>KRP-C_SP, FRS-R, FNQ-R,<br>TCF<br>2475V<br>JCD<br>2750V<br>JCX<br>2750/5500V<br>JCW<br>5500V<br>MV05, 5.5 ABWNA,<br>5.5 AMWNA, 5.5 FFN<br>7200V<br>7.2 AMWNA, 7.2 TDLSJ,<br>~~72 TFLSJ~~<br>Note: Components on the secondary still need<br>overcurrentprotection<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>225%<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary<br>~~600V or~~<br>Below<br>Secondary<br>~~600V or~~<br>Below|**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>250V<br>LPN-RK_SP, FRN-R<br>600V<br>LPS-RK_SP, LPJ-_SP,<br>KRP-C_SP, FRS-R, FNQ-R,<br>TCF<br>2475V<br>JCD<br>2750V<br>JCX<br>2750/5500V<br>JCW<br>5500V<br>MV05, 5.5 ABWNA,<br>5.5 AMWNA, 5.5 FFN<br>7200V<br>7.2 AMWNA, 7.2 TDLSJ,<br>~~72 TFLSJ~~<br>Note: Components on the secondary still need<br>overcurrentprotection<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>225%<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary<br>~~600V or~~<br>Below<br>Secondary<br>~~600V or~~<br>Below|**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>250V<br>LPN-RK_SP, FRN-R<br>600V<br>LPS-RK_SP, LPJ-_SP,<br>KRP-C_SP, FRS-R, FNQ-R,<br>TCF<br>2475V<br>JCD<br>2750V<br>JCX<br>2750/5500V<br>JCW<br>5500V<br>MV05, 5.5 ABWNA,<br>5.5 AMWNA, 5.5 FFN<br>7200V<br>7.2 AMWNA, 7.2 TDLSJ,<br>~~72 TFLSJ~~<br>Note: Components on the secondary still need<br>overcurrentprotection<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary at<br>~~code max. of~~<br>225%<br>Secondary<br>Over 600V<br>Secondary at<br>~~code max. of~~<br>250%<br>Secondary<br>~~600V or~~<br>Below<br>Secondary<br>~~600V or~~<br>Below|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||~~roecon~~<br>Only|||~~nex sanar sze oes no~~<br>correspond to a standard rating||||||Secondary<br>Secondary at<br>~~d f~~||||||||
|||Primary<br>and||||||||||||||||||
||||Primary<br>and|||Transformer<br>~~Id L~~||||Primary<br>at code|||Secondary||Secondary at<br>~~d f~~|||||
|||Secondary<br>Protection|Secondary<br>Protection|||~~mpeance ess~~<br>Than or Equal to 6%||||max. of<br>300%|||Over 600V||~~coe max. o~~<br>250%|||||
||||||Primary<br>at code<br>Transformer<br>Impedance Greater|||||||||||||||
|||||||||||||~~code max. of~~<br>250%<br>Secondary at<br>~~d f~~<br>Secondary<br>~~600V or~~<br>Below||||||**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>250V<br>LPN-RK_SP, FRN-R<br>600V<br>LPS-RK_SP, LPJ-_SP,<br>KRP-C_SP, FRS-R, FNQ-R,<br>TCF<br>2475V<br>JCD<br>2750V<br>JCX<br>2750/5500V<br>JCW<br>5500V<br>MV05, 5.5 ABWNA,<br>5.5 AMWNA, 5.5 FFN<br>7200V<br>7.2 AMWNA, 7.2 TDLSJ,<br>~~72 TFLSJ~~||
|||||||Transformer<br>Impedance Greater||||Primary<br>at code|||Secondary||Secondary at<br>~~d f~~|||||
||||||max.of<br>300%<br>Than 6% But Less<br>Than 10%|Than 6% But Less<br>Than 10%||||max.of<br>300%|||Over 600V||~~coe max. o~~<br>225%|||||
|||||||||||||~~code max. of~~<br>250%<br>~~600V or~~<br>Below||||||||
|**Unsupervised**<br>**Installations**|||Transformer<br>~~Id L~~|||||Primary at code max. of<br>300% or next standard size|||||Secondary||Secondary at code max. of<br>250% or next standard size|||8300V<br>15500V<br>17500V<br>24000V<br>36000V<br>38000V|~~.~~<br>JCZ, JDZ, 8.25 FFN<br>MV155, 15.5 CAVH<br>17.5 CAV, 17.5 TDM<br>24 TDM, 24 TFM, 24 FFM<br>36 CAV, 36 TDQ, 36 TFQ<br>38 CAV|
||||~~mpeance ess~~<br>Than or Equal to 6%|||||if 300% does not corre-<br>spond to a standard rating|||||Over 600V||if 250% does not corre-<br>spond to a standard rating|||||
|||Primary at code max. of<br>300% or next standard size<br>Transformer<br>Impedance Greater||||||||||||||||||
|||||||||||||Secondary<br>Secondary at code max. of<br>225% or next standard size<br>if 125% does not corre-<br>spond to a standard rating<br> <br>Below||||||||
||||Transformer<br>Impedance Greater|||||Primary at code max. of<br>300% or next standard size|||||Secondary||Secondary at code max. of<br>225% or next standard size|||||
|||if 300% does not corre-<br>spond to a standard rating<br>Than 6% But Less<br>Than 10%|Than 6% But Less<br>Than 10%|||||if 300% does not corre-<br>spond to a standard rating|||||Over 600V||if 225% does not corre-<br>spond to a standard rating|||||
||||||||||||||Secondary<br>~~600V~~||Secondary at code max. of<br>125% or next standard size|||||
||||||||||||||~~or~~<br>Below||if 125% does not corre-<br>spond to a standard rating|||||
## **Solid State Devices (Diodes, SCRs, Triacs, Transistors)**
|**Short-Circuit**<br>**Protection**<br>**Only**||~~“F” “S” “K” & 170M Si f id t l i~~||**Fuse Recommendations**<br>**Volts**<br>**Fuse(s)**<br>0-130<br>FWA<br>0-250<br>FWX<br>0-500<br>FWH<br>0-600<br>FWC, KAC, KBC<br>0-700<br>FWP, 170M Series,<br>SPP<br>0-1000<br>FWJ, 170M Series,<br>SPJ|
|---|---|---|---|---|
|||~~, , , eres uses sze up o severa szes~~<br>larger than full load RMS or DC rating of device.|||
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
**16**
## **Low Voltage, Branch Circuit Rated Fuses**
||||||**Page**|
|---|---|---|---|---|---|
|**Fuse Holder & Block Selection Guide 18-20**||||**Fuse Holder & Block Selection Guide 18-20**|**Fuse Holder & Block Selection Guide 18-20**|
|**Class Fuse Dimensions**|||||**21-22**|
|**Fuses By Fuse Class**||||||
|**Class**||**Fuses**|**Volts**|||
|**CC . . . . . .**||LP-CC . . . . . . . . . . . . . . .|600V . . . . .||23|
|||FNQ-R . . . . . . . . . . . . . . .|600V . . . . .||24|
|||KTK-R . . . . . . . . . . . . . . . 600V . . . . .|KTK-R . . . . . . . . . . . . . . . 600V . . . . .||25|
|**CF . . . . . . .**||TCF* . . . . . . . . . . . . . . . .|600V . . . . .||26-27|
|||FCF. . . . . . . . . . . . . . . . . . 600V . . . . .|FCF. . . . . . . . . . . . . . . . . . 600V . . . . .||28-29|
|||WCF. . . . . . . . . . . . . . . . . 600V . . . . .|WCF. . . . . . . . . . . . . . . . . 600V . . . . .||30-31|
|||*Class J performance||||
|**CF . . . . . . .**||Holder System . . . . . . . . .|600V . . . . .||32-33|
|**G . . . . . . .**||SC . . . . . . . . . . . . . . . . . .|600/480V . .||34|
|**J . . . . . . .**||LPJ-_SP . . . . . . . . . . . . 600V . . . . .|. . . . . . . . . . . . 600V . . . . .||35|
|||LPJ-_SPI Indicator . . . . . 600V . . . . .|. . . . . 600V . . . . .||35|
|||JKS . . . . . . . . . . . . . . . . .|600V . . . . .||36|
|**K5 & H . . .**||NON . . . . . . . . . . . . . . . .|250V . . . . .||37|
|||NOS . . . . . . . . . . . . . . . . 600V . . . . .|NOS . . . . . . . . . . . . . . . . 600V . . . . .||37|
|**L . . . . . . .**||KRP-C_SP . . . . . . . . . . . .|600V . . . . .||38-39|
|||KRP-CL . . . . . . . . . . . . . .|600V . . . . .||39|
|||KLU . . . . . . . . . . . . . . . . .|600V . . . . .||40|
|||KTU . . . . . . . . . . . . . . . . .|600V . . . . .||40|
|**RK1 . . . . .**||LPN-RK_SP . . . . . . . . . . .|250V . . . . .||41-43|
|||LPN-RK_SPI Indicator . . .|250V . . . . .||41-43|
|||LPS-RK_SP . . . . . . . . . . .|600V . . . . .||41-43|
|||LPS-RK_SPI Indicator . . . 600V . . . . .|. . . 600V . . . . .||41-43|
|||KTN-R . . . . . . . . . . . . . . .|250V . . . . .||44|
|||KTS-R . . . . . . . . . . . . . . .|600V . . . . .||45|
|**RK5 . . . . .**||FRN-R (Energy Efficient). . . 250V . . . . .|||46|
|||FRN-R_ID (Energy Efficient).600V . . . . .|||46|
|||FRS-R (Energy Efficient). . . 600V . . . . .|||47|
|||FRS-R_ID (Energy Efficient).600V . . . . .|||47|
|**T . . . . . . .**||JJN . . . . . . . . . . . . . . . . .|300V . . . . .||48|
|||JJS . . . . . . . . . . . . . . . . .|600V . . . . .||49|
|**Plug Fuses**||W, SL, TL, S,||||
|||T, P, TC Series & MB||||
|||Edison Base Circuit||||
|||Breakers, SA . . . . . . . . .|125V . . . . .||50-52|
|**REDindicates NEWinformation**<br>—||||||
**17**
**Low Voltage, Branch Circuit Rated Fuses**
## **Holders & Blocks For Branch Circuit Rated Fuses**
**Class Fuses Volts Page** CC LP-CC 600V . . . . . . . . . . . . . . . . . . . . 23 FNQ-R 600V . . . . . . . . . . . . . . . . . . . . 24 KTK-R 600V . . . . . . . . . . . . . . . . . . . . 25
## **Holders**
- OPM-NG-SC3 3-pole, panel/DIN rail mount . . . . . . . . . . . . 284
- OPM-1038R 3-pole, panel/DIN rail mount . . . . . . . . . . . . . 283
- OPM-1038RSW 3-pole w/ switch, panel/DIN rail mount . . 282
- CHCC_D 1 to 3-pole, DIN rail mount . . . . . . . . . . . . . . . . . 274
- HPF-RR, front panel mount . . . . . . . . . . . . . . . . . . . . . . . 317
- • HPS-RR, front panel mount . . . . . . . . . . . . . . . . . . . . . . . 317
## **Blocks**
- BC Series, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . . 305
**==> picture [216 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
OPM-NG-SC3 OPM-1038R & CHCC_D<br>OPM-1038RSW<br>HPF-RR HPS-RR BC Series<br>**----- End of picture text -----**<br>
**Class Fuses Volts Page** G SC 600/480V . . . . . . . . . . . . . . . . . 34 **Holders**
- HP Series front panel accessible, front panel mount . . . . . 317
## **Blocks**
- BG Series, panel/DIN rail with adapters . . . . . . . . . . . . . . 305
**==> picture [150 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
HP Series<br>BG & G Series<br>**----- End of picture text -----**<br>
- G Series, panel/DIN rail with adapters . . . . . . . . . . . . . . . 305
**Class Fuses Volts Page** K5 & H NON 250V . . . . . . . . . . . . . . . . . . . . 37 NOS 600V . . . . . . . . . . . . . . . . . . . . 37 **Blocks** • Modular Knifeblade Fuse Blocks 250/600V, panel mount . . 289
- Modular Type Fuse Blocks 250/600V, panel mount . . . . . . 306
- H250 Series 1 to 3-pole 250V, panel mount . . . . . . . . . . . .294
- H600 Series 1 to 3-pole 600V, panel mount . . . . . . . . . . . 296
**==> picture [167 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
Modular Knifeblade Modular Type<br>H250 Series H600 Series<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**18**
**Low Voltage, Branch Circuit Rated Fuses**
## **Holders & Blocks For Branch Circuit Rated Fuses**
**Class Fuses Volts Page** L KRP-C_SP 600V . . . . . . . . . . . . . . . . . . . . 38 KRP-CL 600V . . . . . . . . . . . . . . . . . . . . 39 KLU 600V . . . . . . . . . . . . . . . . . . . . 40 KTU 600V . . . . . . . . . . . . . . . . . . . . 40
## **Blocks**
- 51215 1-pole, panel mount*
- 51235 3-pole, panel mount*
*Call our customer satisfaction team at 636-527-3877 for more information.
**==> picture [83 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
51215 51235<br>**----- End of picture text -----**<br>
## **Class**
**Class Fuses Volts Page** RK1 LPN-RK_SP 250V . . . . . . . . . . . . . . . . . . . . .41 LPS-RK_SP 600V . . . . . . . . . . . . . . . . . . . . .41 KTN-R 250V . . . . . . . . . . . . . . . . . . . . 44
## **Blocks**
- Modular Knifeblade Fuse Blocks 250/600V, panel mount . . .289
- R250 Series 1- to 3-pole 250V, panel mount . . . . . . . . . . . .294
**==> picture [234 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Modular Knifeblade R250 Series R600 Series<br>**----- End of picture text -----**<br>
- R600 Series 1- to 3-pole 600V, panel mount . . . . . . . . . . . .296
**Class Fuses Volts Page** RK5 FRN-R 250V . . . . . . . . . . . . . . . . . . . . 46
## **Blocks**
- Modular Knifeblade Fuse Blocks 250/600V, panel mount . . . 289
- R250 Series 1- to 3-pole 250V, panel mount . . . . . . . . . . . .294
- R600 Series 1- to 3-pole 600V, panel mount . . . . . . . . . . . .296
**==> picture [240 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Modular Knifeblade R250 Series R600 Series<br>**----- End of picture text -----**<br>
|**Class**<br>**Fuses**<br>**Volts**<br>**Page**|
|---|
|T<br>JJN<br>300V . . . . . . . . . . . . . . . . . . . . 48<br>JJS<br>600V . . . . . . . . . . . . . . . . . . . . 49<br>**Blocks**<br>• BH Series modular-style, panel mount (<60A) . . . . . . . . . . 306|
|• T300 Series 1 to 4-pole 300V, panel mount . . . . . . . . . . . .300|
|• T600 Series 1 to 3-pole 600V, panel mount . . . . . . . . . . . .302|
**==> picture [226 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
BH Series T300 Series T600 Series<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**19**
**Low Voltage, Branch Circuit Rated Fuses**
## **Holders & Blocks For Branch Circuit Rated Fuses**
**Class Fuses Volts Page** J, CF TCF*, FCF, WCF 600V . . . . . . . . . . . . . . . . 31 LPJ-SP 600V . . . . . . . . . . . . . . . . 35 JKS 600V . . . . . . . . . . . . . . . . 36
*Class J performance
## **Holders**
- TCFH CUBEFuse holder, panel/DIN-Rail mount . . . . . . . 32-33
- CH Series Class J modular 1- to 3-pole, panel/ DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
- Safety J™ Series modular holders, panel/DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286
## **Blocks**
- Modular Knifeblade Fuse Blocks 250/600V, panel mount . . 289
- Modular Type Fuse Blocks 600V, panel mount . . . . . . . . . .306
- J600 Series, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . 298
- JP Series pyramid blocks, panel mount . . . . . . . . . . . . . . .299
**==> picture [243 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
TCFH CH Series Safety J™ Series Modular Type<br>.<br> oe shee= =<br>L<br>bend ‘ ~' $ Se.<br>Modular J600 Series JP Series BH Series<br>Knifeblade<br>**----- End of picture text -----**<br>
- BH Series modular-style open blocks, panel mount . . . . . 306
**Class Fuses Volts Page** Plug Fuses W, SL*, TL, S*, T, P and TC Series 125V . . . . . . . . . . . . . . . . . . 50-52 **Box Cover Units** • Standard electrical box mounting . . . . . . . . . . . . . . . . . . . 307
*Use of SL & S rejection fuses requires SA adapters, see page 52
**==> picture [200 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse Only With Grounded With Switch<br>Outlet<br>**----- End of picture text -----**<br>
## **Fuse Reducers For Class R Fuses 250V**
## **Fuse Reducers For Class R Fuses 600V**
|**Equipment**<br>**Fuse Clip Amps**|**Desired Fuse**<br>**(Case) Amp Size**|**Catalog No.**<br>**(Pairs) 250V**|**Equipment**<br>**Fuse Clip Amps**|**Desired Fuse**<br>**(Case) Amp Size**|**Catalog No.**<br>**(Pairs) 600V**|
|---|---|---|---|---|---|
|60|30|NO.263-R|60|30|NO.663-R|
|100|30|NO.213-R|100|30|NO.216-R|
||60|NO.216-R||60|NO.616-R|
|200|60|NO.226-R|200|60|NO.626-R|
||100|NO.2621-R||100|NO.2621-R|
|400|100|NO.2641-R|400|100|NO.2641-R|
||200|NO.242-R||200|NO.642-R|
|600|100|NO.2661-R|600|100|NO.2661-R|
||200|NO.2662-R||200|NO.2662-R|
||400|NO.2664-R*||400|NO.2664-R*|
*Single reducer only (pair not required).
*Single reducer only (pair not required).
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**20**
**Low Voltage, Branch Circuit Rated Fuses**
## **Branch Circuit Rated Fuse Dimensions**
## **Class J Dimensions - in (mm)**
## **Low-Peak and Limitron Fuses LPJ & JKS — 600V**
|Amp Range<br>A<br>B<br>C<br>D|Amp Range<br>A<br>B<br>C<br>D|Amp Range<br>A<br>B<br>C<br>D|Amp Range<br>A<br>B<br>C<br>D|Amp Range<br>A<br>B<br>C<br>D||E<br>F<br>G<br>H<br>I|E<br>F<br>G<br>H<br>I|E<br>F<br>G<br>H<br>I|E<br>F<br>G<br>H<br>I|E<br>F<br>G<br>H<br>I|E<br>F<br>G<br>H<br>I|
|---|---|---|---|---|---|---|---|---|---|---|---|
|1-30<br>2.25 (57.2)<br>0.81 (20.6)<br>—<br>—||||||0.50 (12.7)<br>—<br>—<br>—<br>—||||||
|35-60<br>2.38 (60.3)<br>1.06 (27.0)<br>—<br>—||||||0.63 (15.9)<br>—<br>—<br>—<br>—||||||
|65-100<br>4.63 (117.5)<br>1.13 (28.6)<br>3.63 (92.1)<br>2.63 (66.7)||||||1.00 (25.4)<br>0.75 (28.6)<br>0.13 (3.2)<br>0.41 (10.4)<br>0.28 (7.1)||||||
|110-200<br>5.75 (146.1)<br>1.63 (41.4)<br>4.38 (111.1)<br>3.00 (76.2)||||||1.38 (34.9)<br>1.13 (28.6)<br>0.19 (4.8)<br>0.38 (9.5)<br>0.28 (7.1)||||||
|225-400<br>7.12 (181.0)<br>2.11 (53.6)<br>5.25 (133.3)<br>3.26 (82.8)||||||1.87 (47.6)<br>1.62 (41.2)<br>0.25 (6.4)<br>0.56 (14.2)<br>0.40 (10.3)||||||
|450-600<br>8.00 (203.2)<br>2.60 (66.0)<br>6.00 (152.4)<br>3.31 (84.0)||||||2.12 (54.0)<br>2.00 (50.8)<br>0.53 (13.5)<br>0.72 (18.3)<br>0.53 (13.5)||||||
|||||||||||||
|~~**A**~~<br>**B**<br>**E**<br>**1A to 60A**<br>||||||**A**<br>~~**C**~~<br>**D**|||||**B**<br>**F**<br>**G**<br>**I**|
|||~~**A**~~|**B**<br>**E**|||||||||
|||||||||||||
|||||||||||||
||||||||**H**||~~**E**~~|||
## **Class CC Dimensions - in (mm)**
**==> picture [199 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.5" (±0.031)<br>(38.1mm)<br>0.41" (±0.005)<br>(10.3mm)<br>**----- End of picture text -----**<br>
## **Class RK1 & RK5 Dimensions - in (mm)**
Basic dimensions are same as Class H (formerly NEC) One-Time (NON & NOS) and Superlag Renewable RES & REN fuses. NOTE: These fuses can be used to replace existing Class H, RK1 and RK5 fuses relating to dimensional compatibility.
|**Ferrule Styles**<br>**Amp**<br>**250V**<br>**600V**<br>**Range**<br>**A**<br>**B**<br>**A**<br>**B**<br>1⁄10-30<br>2 (50.8)<br>0.56 (14.3)<br>5.0 (127.0)<br>0.81 (20.6)<br>35-60<br>3(76.2)<br>0.81(20.6)<br>5.5(139.7)<br>1.06(27.0)<br>**Fusetron — (FRN-R & FRS-R)& Limitron — (KTN-R & KTS-R)**<br>**Amp**<br>**250V**<br>**600V**<br>**Range**<br>**A**<br>**B**<br>**A**<br>**B**<br>70-100<br>5.88 (149.2)<br>1.06 (26.9)<br>7.88 (200.0)<br>1.34 (34.0)<br>110-200<br>7.13(181.0)<br>1.56(39.6)<br>9.63(244.5)<br>1.84(46.7)<br>225-400<br>8.63(219.1)<br>2.38(60.5)<br>11.63(295.3)<br>2.59(65.8)<br>450-600<br>10.38(263.5)<br>2.88(73.2)<br>13.38(339.7)<br>3.13(79.5)<br>**Low-Peak — (LPN-RK & LPS-RK)**<br>**Amp**<br>**250V**<br>**600V**<br>**Range**<br>**A**<br>**B**<br>**A**<br>**B**<br>70-100<br>5.88 (149.2)<br>1.16 (29.5)<br>7.88 (200.0)<br>1.16 (29.5)<br>110-200<br>7.13(181.0)<br>1.66(42.2)<br>9.63(244.5)<br>1.66(42.2)<br>225-400<br>8.63(219.1)<br>2.38(60.5)<br>11.63(295.3)<br>2.38(60.5)<br>450-600<br>10.38 (263.5)<br>2.88 (73.2)<br>13.38 (339.7)<br>2.88 (73.2)|||||**B**|**B**|**B**|
|---|---|---|---|---|---|---|---|
||||~~**A**~~|||||
|||||||||
|||||||**B**||
|||||||||
|||||||||
||||~~**A**~~|||||
|||||||||
|||||||||
|||||||||
|||||||||
||||~~**A**~~|||||
|||||||||
|||||||||
|||||||||
|||||||||
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**21**
**Low Voltage, Branch Circuit Rated Fuses**
## **Branch Circuit Rated Fuse Dimensions**
## **Class L Dimensions - in (mm)**
## **Low-Peak and Limitron Fuses**
|**Amp**<br>**Range**<br>**A**<br>**B**<br>**C1**<br>**C2**<br>**D**|**Amp**<br>**Range**<br>**A**<br>**B**<br>**C1**<br>**C2**<br>**D**|**F**|**F**|**G**|**G**|**G**|**G**|**G**|**I**|**I**|**I**||**J1**<br>**J**|**J1**<br>**J**|**J1**<br>**J**|**J1**<br>**J**|**2**<br>**J3**|**2**<br>**J3**|**2**<br>**J3**|**2**<br>**J3**|**2**<br>**J3**|**2**<br>**J3**|**J4**<br>—<br>—<br>—<br>—<br>0.81 (20.6)<br>0.81 (20.6)<br>0.88 (22.2)<br>0.88 (22.2)<br>0.88 (22.2)|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|601-800<br>8.63 (219.1)<br>2.40 (61.0)<br>6.75 (171.5)<br>5.75 (146.1)<br>3.75 (95.3)||2.0||0 (50.8)<br>0.38|||||(9.5)<br>0.6|||3 (15.9)|—<br>—||||—|||||||
|801-1200<br>10.75 (273.1)<br>2.40 (61.0)<br>6.75 (171.5)<br>5.75 (146.1)<br>3.75 (95.3)||2.0||0 (50.8)<br>0.38|||||(9.5)<br>0.6|||3 (15.9)|—<br>—||||—|||||||
|1350-1600<br>10.75 (273.1)<br>3.00 (76.2)<br>6.75 (171.5)<br>5.75 (146.1)<br>3.75 (95.3)||2.3||8 (60.3)<br>0.44|||||(11.1)<br>0.6|||3 (15.9)|—<br>—||||—|||||||
|1800-2000<br>10.75 (273.1)<br>3.50 (88.9)<br>6.75 (171.5)<br>5.75 (146.1)<br>3.75 (95.3)||2.7||5 (69.9)<br>0.50|||||(12.7)<br>0.6|||3 (15.9)|—<br>—||||—|||||||
|<br> <br> <br> <br> <br>2001-2500<br>10.75 (273.1)<br>4.80 (122.0)<br>6.75 (171.5)<br>5.75 (146.1)<br>3.75 (95.3)||<br>3.5||<br> <br>0 (88.9)<br>0.75|||||<br> <br>(19.1)<br>0.6|||<br>3 (15.9)|1.75 (44.5)<br>1||||.38 (34.9)<br>0.88 (22.2)|||||||
|<br> <br> <br> <br> <br>3000<br>10.75 (273.1)<br>5.00 (127.0)<br>6.75 (171.5)<br>5.75 (146.1)<br>3.75 (95.3)||<br>4.0||<br> <br>0 (101.6)<br>0.75|||||<br> <br>(19.1)<br>0.6|||<br>3 (15.9)|<br> <br>1.75 (44.5)<br>1||||<br> <br>.38 (34.9)<br>0.88 (22.2)|||||||
|<br> <br> <br> <br> <br>3500-4000<br>10.75 (273.1)<br>5.75 (146.1)<br>6.75 (171.5)<br>5.75 (146.1)<br>3.75 (95.3)||<br>4.7||<br> <br>5 (120.7)<br>0.75|||||<br> <br>(19.1)<br>0.6|||<br>3 (15.9)|<br> <br>1.75 (44.5)<br>1||||<br> <br>.38 (34.9)<br>1.63 (41.3)|||||||
|<br> <br> <br> <br> <br>4500-5000<br>10.75 (273.1)<br>6.25 (158.8)<br>6.75 (171.5)<br>5.75 (146.1)<br>3.75 (95.3)||<br>5.2||<br> <br>5 (133.4)<br>1.00|||||<br> <br>(25.4)<br>0.6|||<br>3 (15.9)|<br> <br>1.75 (44.5)<br>1||||<br> <br>.38 (34.9)<br>1.63 (41.3)|||||||
|<br> <br> <br> <br> <br>6000<br>10.75 (273.1)<br>7.13 (181.0)<br>6.75 (171.5)<br>5.75 (146.1)<br>3.75 (95.3)||<br>5.7||<br> <br>5 (146.1)<br>1.00|||||<br> <br>(25.4)<br>0.6|||<br>3 (15.9)|<br> <br>1.75 (44.5)<br>1||||<br> <br>.38 (34.9)<br>1.63 (41.3)|||||||
|NOTE: KRP-CL (150A to 600A) fuses have same||||||||||||||||||||||||
||||||||||||||||||||||||~~**B**~~<br>~~**F**~~<br>**G**|
|<br>dimensions as 601-800A case size. KTU (200-600A)<br>have same dimensions, except tube 3” length x 2”<br>diameter (76.2 x 50.8mm); terminal 15⁄8” width x 11⁄4”<br>thick (41.3 x 31.8mm).||||||||||||||||||||||||
||**A**|**ll Slo**||**ts a**|**nd Holes**<br>**I**|||||**3**|||**J1**<br>**J3**||||**J2**<br>**J4**||||||~~**F**~~<br>**G**|
|||||||||||||||||||||||||
||||||||||**J1**|||**J2**||||||||||||
|||||||||||||**J4**||||||||||||
|||||||||||||||||||||||||
|||||||||||||||||||||||||
||**A**<br>|||||||||||||||||||||||
|||**A**<br>**C1**||||||||||||||||||||||
||||**1**|||||||||||||||||||||
|||||||**C**<br>|**2**|||||**1A**<br>**o**<br>**0A**||||||||||||
|||||**601A**<br>**to**<br>**800A**||||**801A**<br>**to**<br>**2000A**|||**200**<br>**t**<br>**300**|**1A**<br>**o**<br>**0A**|**3500A**<br>**to**<br>**4000A**||||**4500A**<br>**to**<br>**6000A**|||||||
|||||||||||||||||||||||||
|||||||||||||||||||||||||
||||||||||||||||||||||||~~**B**~~|
|||||||||||||||||||||||||
## **Class T Dimensions - in (mm)**
## **T-Tron Fuses**
## **JJN — 300V**
|Amp Range|A|B|C|D|
|---|---|---|---|---|
|1-30|0.88 (22.2)|0.41 (10.3)|—|—|
|35-60|0.88 (22.2)|0.56 (14.3)|—|—|
|70-100|2.16 (54.8)|0.75 (19.1)|1.56 (39.7)|0.84 (21.4)|
|110-200<br>225-400<br>450-600|2.44 (61.9)<br>2.75 (69.9)<br>3.06 (77.8)|0.88 (22.2)<br>1.00 (25.4)<br>1.25 (31.8)|1.69 (42.9)<br>1.84 (46.8)<br>2.03 (51.6)|0.84( 21.4)<br>0.86 (21.8)<br>0.88 (22.2)|
|601-800|3.38 (85.7)|1.75 (44.5)|2.22 (56.4)|0.89 (22.6)|
|801-1200|4.00 (101.6)|2.00 (50.8)|2.53 (64.3)|1.08 (27.4)|
## **JJS — 600V**
|Amp Range|A|B|C|D|
|---|---|---|---|---|
|1-30|1.50 (14.3)|0.56 (38.1)|—|—|
|35-60|1.56 (20.6)|0.81 (39.7)|—|—|
|70-100|2.95 (19.1)|0.75 (75.0)|2..36 (59.9)|1.64 (41.7)|
|110-200|3.25 (22.2)|0.88 (82.6)|2.50 (63.5)|1.66 (42.1)|
|225-400|3.63 (25.4)|1.00 (92.1)|2.72 (69.1)|1.73 (44.1)|
|450-600|3.98 (31.8)|1.25 (101.2)|2.96 (75.0)|1.78 (45.2)|
|601-800|4.33 (44.5)|1.75 (109.9)|3.17 (80.6)|1.88 (47.6)|
**==> picture [132 x 133] intentionally omitted <==**
JJS 35A to 60A
**==> picture [86 x 57] intentionally omitted <==**
JJN 70A to 1200A JJS 70A to 800A
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**22**
**Low Voltage, Branch Circuit Rated Fuses**
## **Low-Peak[™] Time-delay, Rejection-Type Fuses**
## **LP-CC Class CC**
## **Specifications**
**Description:** Time-delay, current-limiting, rejection-type fuse – 12 seconds (minimum) at 200% rated amps.
**Dimensions:**[13] ⁄32˝ x 1[1] ⁄2˝ (10.3 x 38.1mm). **Ratings:**
Volts — 600Vac (or less)
- 300Vdc ([1] ⁄2-2[1] ⁄2A & 20-30A)
- 150Vdc (2[8] ⁄10-15A)
Amps —[1] ⁄2-30A IR — 200kA RMS Sym. — 20kA DC
**Agency Information:** CE, Std. 248-4, Class CC, UL Listed, Guide JDDZ, File E4273, CSA Certified; Class 1422-02, File 53787.
## **Features and Benefits**
- Time-delay coupled with Class CC current-limiting response provides close sizing on small motor and relay circuits, and maximum component short-circuit current rating protection.
- 200kA interrupting rating provides high ratings for control circuit locations.
- Class CC rejection feature, with appropriate fuse block, prevents inserting lesser-rated supplementary fuses.
- Inventory consolidation of[13] ⁄32 x 1[1] ⁄2 inch supplementary fuses reduces SKU investment and minimizes potential for misapplying fuse.
- Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit.
## **Time Current Characteristics—Average Melt**
**==> picture [218 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
AMP<br>RATING<br>200 (|<br>100 AWAWW<br>ARAL— \ A A MWAA Y AYYY<br>— VAY \AY\\\E<br>DEANS<br>10<br>WH)nn ee) Vs Vea Yi VeenAWAWYYWe Ok \ |OQ<br>ees een) ht<br>1<br>feeeees eeeeee 10) Oe)ee ||OO eseeOe(||On Uo<br>TPEWA<br>TE AA<br>.1 WELW<br>TE AAW<br>EAA<br>ene Ve 0 Ve) eee nV<br>TE AW AWA<br>.01 THEE AWA<br>CURRENT IN AMPS<br>⁄/™ fl/¡º °/¡º 1 1⁄/¢ 3 3⁄/™4 4⁄/™6 8 10 12 15 20 25 30<br>TIME IN SECONDS<br>.4 1 10 100 1000<br>**----- End of picture text -----**<br>
## **Current Limitation Curves**
## **Typical Applications**
- Specialized Circuits
- Industrial Control
- Isolated, In-Line Fuse Holder
## **Catalog Numbers (Amps)**
|**Catalog Numbers (Amps)g Numbers (Amps) Numbers (Amps)(Amps)Amps)ps)s))**<br>LP-CC-1⁄2<br>LP-CC-2-1⁄2<br>LP-CC-71⁄2<br>~~oe~~|
|---|
|LP-CC-6⁄10<br>LP-CC-2-8⁄10<br>LP-CC-8|
|LP-CC-8⁄10<br>LP-CC-3<br>LP-CC-9<br>LP-CC-1<br>LP-CC-3-2⁄10<br>LP-CC-10<br>LP-CC-1-1⁄8<br>LP-CC-3-1⁄2<br>LP-CC-12<br>LP-CC-1-1⁄4<br>LP-CC-4<br>LP-CC-15<br>LP-CC-1-4⁄10<br>LP-CC-4-1⁄2<br>LP-CC-20<br>LP-CC-1-1⁄2<br>LP-CC-5<br>LP-CC-25<br>LP-CC-1-6⁄10<br>LP-CC-5-6⁄10<br>LP-CC-30<br>LP-CC-1-8⁄10<br>LP-CC-6<br>LP-CC-2<br>LP-CC-6-1⁄4<br>~~SEE~~<br>~~OO~~<br>~~—oo~~<br>~~a~~<br>~~a~~<br>~~oo) ~~|
|LP-CC-2-1⁄4<br>LP-CC-7|
• See page 18
**Recommended Fuse Holders & Blocks For Class CC Fuses**
**Data Sheet: 1023**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**23**
**Low Voltage, Branch Circuit Rated Fuses**
## **CC-Tron Rejection-type Fuses**
## **FNQ-R Class CC**
## **Time-Current Characteristic Curves—Average Melt**
|**Specifications**<br>**Description:**Time-delay, branch circuit,<br>rejection-type fuse.<br>**Dimensions:** 13⁄32˝ x 11⁄2˝ (10.3 x 38.1mm).<br>**Ratings:**|=|100|100|FNQ-R-1/2|FNQ-R-1|||FNQ-R-3|FNQ-R-3||FNQ-R-5|FNQ-R-5||FNQ-R-7-1/2|||||||||||AMP<br>RATING|AMP<br>RATING|AMP<br>RATING|AMP<br>RATING|AMP<br>RATING|AMP<br>RATING|AMP<br>RATING|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Volts — 600Vac (or less)||||||||||||||||||||||||||||||||
|— 300Vdc (15-20A)<br>— 32Vdc (Self Certified)<br>Amps —1⁄4-30A|3|||1h<br>OV<br>A||||||||||||||||||||||||||||
|IR — 200kA RMS Sym.||||||||||||||||||||||||||||||||
|— 20kA DC (15 & 20A only)||||||||||||||||||||||||||||||||
|**Agency Information:** CE, Std. 248-4, Class CC, UL|||10|||||||||||||||||||||||||||||
|Listed, Guide JDDZ, File E4273 CSA Certified,||||||||||||||||||||||||||||||||
|Class 1422-01, File 53787.||||||||||||||||||||||||||||||||
|**Features and Benefits**<br> Time-delay compatible with inrush characteristic of small<br>control transformers.<br> Current limitation at Class CC levels provides maximum<br>component short-circuit current rating protection.<br> 200kA interrupting rating provides high ratings for control<br>circuit locations.<br> Class CC rejection feature, with appropriate fuse block,<br>prevents inserting lesser-rated supplementary fuses.<br>**Typical Applications**||TIME IN SECONDS|1|YA AAT<br>ee<br>TNT ONY||||||||||||||||||||||||||||
|Line Protection, Small Control Transformers||||||||||||||||||||||||||||||||
|Industrial Control||0.01||||||||||||||||||||||||||||||
|Isolated, In-Line Fuse Holders||||||||||||||||||||||||||||||||
|**Catalog Numbers(Amps)**||||||||||||||||||||||||||||||||
|FNQ-R-1⁄4<br>FNQ-R-1-6⁄10<br>FNQ-R-6<br>FNQ-R-3⁄10<br>FNQ-R-1-8⁄10<br>FNQ-R-6-1⁄4<br>FNQ-R-4⁄10<br>FNQ-R-2<br>FNQ-R-7<br>FNQ-R-1⁄2<br>FNQ-R-2-1⁄4<br>FNQ-R-7-1⁄2<br>FNQ-R-6⁄10<br>FNQ-R-2-1⁄2<br>FNQ-R-8<br>0.01<br>~~TT~~INCI<br>~~TI~~AA||||||||||||||||||||||||||||||||
|FNQ-R-3⁄4<br>FNQ-R-2-8⁄10<br>FNQ-R-8⁄10<br>FQN-R-3|FNQ-R-9<br>FNQ-R-10||0.08<br>1||||||||||10<br>100<br>CURRENT IN AMPS|||||||||||200||300||400||500||
|FNQ-R-1<br>FNQ-R-3-2⁄10|FNQ-R-12|||||||||||||||||||||||||||||||
|FNQ-R-1-1⁄8<br>FNQ-R-3-1⁄2|FNQ-R-15|||||||||||||||||||||||||||||||
|FNQ-R-1-1⁄4<br>FNQ-R-4|FNQ-R-17-1⁄2|||||||||||||||||||||||||||||||
|FNQ-R-1-3⁄10<br>FNQ-R-4-1⁄2|FNQ-R-20|||||||||||||||||||||||||||||||
|FNQ-R-1-4⁄10<br>FNQ-R-5|FNQ-R-25|||||||||||||||||||||||||||||||
|FNQ-R-1-1⁄2<br>FNQ-R-5-6⁄10|FNQ-R-30|||||||||||||||||||||||||||||||
Amps —[1] ⁄4-30A IR — 200kA RMS Sym.
- Time-delay compatible with inrush characteristic of small control transformers.
- Current limitation at Class CC levels provides maximum component short-circuit current rating protection.
- 200kA interrupting rating provides high ratings for control circuit locations.
- Class CC rejection feature, with appropriate fuse block, prevents inserting lesser-rated supplementary fuses.
- Line Protection, Small Control Transformers
- Industrial Control
- Isolated, In-Line Fuse Holders
For superior electrical protection, Bussmann recommends upgrading FNQ-R fuse applications to Low-Peak LP-CC fuses See page 17.
**Recommended Fuse Holders & Blocks For Class CC 600V Fuses**
- See page 18
**Data Sheet: 1014**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**24**
**Low Voltage, Branch Circuit Rated Fuses**
## **Limitron[™] Rejection-type Fuses**
## **KTK-R Class CC**
## **Specifications**
**Description:** Fast-acting, branch circuit, rejection-type fuse. **Dimensions:**[13] ⁄32˝ x 1[1] ⁄2˝ (10.3 x 38.1mm).
**Time-Current Characteristic Curves—Average Melt** totaoe AMP 300 = 865 8 $2 288 RATING
**Ratings:**
Volts — 600Vac (or less) Amps —[1] ⁄10-30A
IR — 200kA RMS Sym.
**Agency Information:** CE, Std. 248-4, Class CC, UL Listed, Guide JDDZ, File E4273 CSA Certified, File 53787, Class 1422-02.
## **Features and Benefits**
- Current limitation at Class CC levels provides maximum component short-circuit current protection.
- 200kA interrupting rating provides high ratings for control circuit locations.
- Class CC rejection feature, with appropriate fuse block, prevents inserting lesser-rated supplementary fuses.
## **Typical Applications**
- Specialized Circuits
- Industrial Control
- Isolated, In-Line Fuse Holders (street lighting)
## **Catalog Numbers (Amps)**
|KTK-R-1⁄10|KTK-R-1|KTK-R-7|
|---|---|---|
|KTK-R-1⁄8|KTK-R-1-1⁄2|KTK-R-8|
|KTK-R-2⁄10|KTK-R-2|KTK-R-9|
|KTK-R-1⁄4|KTK-R-2-1⁄2|KTK-R-10|
|KTK-R-3⁄10|KTK-R-3|KTK-R-12|
|KTK-R-4⁄10|KTK-R-3-1⁄2|KTK-R-15|
|KTK-R-1⁄2|KTK-R-4|KTK-R-20|
|KTK-R-6⁄10|KTK-R-5|KTK-R-25|
|KTK-R-3⁄4|KTK-R-6|KTK-R-30|
For superior electrical protection, Bussmann recommends upgrading KTK-R fuse applications to Low-Peak LP-CC fuses See page 23.
**Recommended Fuse Holders & Blocks For Class CC Fuses**
• See page 18
**Data Sheet: 1015**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**25**
**Low Voltage, Branch Circuit Rated Fuses**
## **Time-Delay Low-Peak CUBEFuse[™] Finger-safe Fuse and Fuse Holder System**
## **TCF Class CF**
**==> picture [68 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Available With<br>Indication<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Finger-safe fuse and fuse holder system; dual-element, time-delay fuse; 10 seconds minimum operating time at 500% rated amps.
**Dimensions:** See Dimensions illustration.
**Poles:** 1-pole (gangable)
## **Ratings:**
Volts — 600Vac (or less)
- 300Vdc (or less)
|**Fuse Catalog Numbers Indicatin**|**Numbers Indicatin**|**Numbers Indicating (Amps)**||
|---|---|---|---|
|TCF6<br>TCF10|TCF25<br>TCF30|TCF50<br>TCF60|TCF100|
|TCF15|TCF35|TCF70||
|TCF17-1⁄2|TCF40|TCF80||
|TCF20|TCF45|TCF90||
|**Fuse Catalog Numbers Non-Indicatin**|**Numbers Non-Indicatin**|**Numbers Non-Indicating (Amps)**||
|TCF1RN<br>~~On~~|TCF17-1⁄2RN<br>~~On~~|TCF40RN<br>~~On~~|TCF80RN<br>~~On~~|
|TCF3RN|TCF20RN|TCF45RN|TCF90RN|
|TCF6RN|TCF25RN|TCF50RN|TCF100RN|
|TCF10RN|TCF30RN|TCF60RN||
|TCF15RN|TCF35RN|TCF70RN||
## Carton Quantity and Weight
|Amp<br>Rating|Carton<br>Qty.|Weight Per Carton|Weight Per Carton|
|---|---|---|---|
|||lbs|kg|
|TCF1-30A|12|1.39|0.63|
|TCF35-60A|12|1.42|0.65|
|TCF70-100A|6|1.74|0.79|
- Amps — 1-100A IR — 300kA RMS Sym. (UL)
- 200kA RMS Sym. (CSA)
- 100kA DC (UL & CSA)
**Agency Information:** CE, UL Listed Guide JFHR, File E4273, CSA Certified Fuse: Class 1422- 02, File 53787, UL Listed Fuse holder: Guide IZND, File E214079, CSA Certified Fuse holder: Class 6225-01, File 47235.
## **Features and Benefits**
- Separate overload and short-circuit elements provide time delay for sizing of high inrush loads linked with Class J current limitation.
Scan this tag to get the latest product information for the TCF CUBEFuse.
- Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit.
- Smallest footprint of any Class CC, J, T or RK fuse provides substantial space savings and installation flexibility.
- IEC 60529 and finger-safe rating provides enhanced workplace safety.
## **Typical Applications**
- Electrical Panelboards
- Machinery Disconnects
- Industrial Control
- Required Finger-Safe Systems
## **Recommended Fuse Holders For Class CF Fuses**
- See pages 32 and 33
## **Data Sheet: 9000 (fuses) and 9007 (holders)**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**26**
**Low Voltage, Branch Circuit Rated Fuses**
## **Time-Delay Low-Peak CUBEFuse[™] Finger-safe Fuse and Fuse Holder System**
## **Dimensions for CUBEFuse Fuse and Fuse Holder**
## **Current Limitation Curves**
||tT|tT|tT|tT|tT|tT|tT|
|---|---|---|---|---|---|---|---|
|Fuse<br>Amps|Dimensions - in (mm)<br>tT|||||||
||A<br>tT|B<br>tT|C<br>tT|D<br>tT|E<br>tT|F<br>tT|G<br>tT|
|1-15|1.88<br>(47.75)|0.75<br>(19.05)|1.00<br>(25.40)|0.23<br>(5.84)|0.04<br>(1.02)|0.63<br>(15.93)|0.28<br>(7.11)|
|171⁄2|1.88<br>(47.75)|0.75)<br>(19.05)|1.00<br>(25.40)|0.31<br>(7.87)|0.04<br>(1.02)|0.63<br>(15.93)|0.28<br>(7.11)|
|20|1.88<br>(47.75)|0.75)<br>(19.05)|1.00<br>(25.40)|0.31<br>(7.87)|0.04<br>(1.02)|0.63<br>(15.93)|0.28<br>(7.11)|
|25-30<br>~~Pf}~~|1.88<br>(47.75)<br>~~Pf}ff~~|0.75<br>(19.05)<br>~~ff~~|1.00<br>(25.40)<br>~~fffff~~|0.31<br>(7.87)<br>~~fff~~|0.04<br>(1.02)<br>~~fff~~|0.63<br>(15.93)<br>~~fff~~|0.28<br>(7.11)|
|35-40<br>~~Pf}~~|2.13<br>(54.10)<br>~~Pf}ff~~|1.00<br>(25.40)<br>~~ff~~|1.13<br>(28.58)<br>~~fffff~~|0.36<br>(9.10)<br>~~fff~~|0.04<br>(1.02)<br>~~fff~~|0.63<br>(15.93)<br>~~fff~~|0.38<br>(9.65)|
|45-50<br>~~Pf}~~|2.13<br>(54.10)<br>~~Pf} ff~~|1.00<br>(25.40)<br>~~ff~~|1.13<br>(28.58)<br>~~ff fff~~|0.44<br>(11.13)<br>~~fff~~|0.04<br>(1.02)<br>~~fff~~|0.63<br>(15.93)<br>~~fff~~|0.38<br>(9.65)|
|60<br>~~|~~<br>~~Ff~~|2.13<br>(54.10)<br>~~|~~<br>~~Ff~~|1.00<br>(25.40)<br>~~**|**~~<br>~~FfYT~~|1.13<br>(28.58)<br>~~YT~~|0.44<br>(11.13)<br>~~YTyy~~|0.04<br>(1.02)<br>~~yy~~|0.63<br>(15.93)<br>~~yy~~|0.38<br>(9.65)<br>~~yy~~|
|70<br>~~|~~<br>~~Ff~~|3.01<br>(76.45)<br>~~|~~<br>~~Ff~~|1.00<br>(25.40)<br>~~**|**~~<br>~~FfYT~~|1.26<br>(32.00)<br>~~YT~~|0.49<br>(12.45)<br>~~YTyy~~|0.06<br>(1.60)<br>~~yy~~|0.58<br>(14.78)<br>~~yy~~|0.38<br>(9.65)<br>~~yy~~|
|80-90<br>~~Ff~~<br>ef]|3.01<br>(76.45)<br>~~Ff~~<br>ef]fof|1.00<br>(25.40)<br>~~Ff YT~~<br>fof|1.26<br>(32.00)<br>~~YT~~<br>fof~~fp~~|0.49<br>(12.45)<br>~~YT yy~~<br>~~fp~~|0.06<br>(1.60)<br>~~yy~~<br>~~fpfp~~|0.58<br>(14.78)<br>~~yy~~<br>~~fp~~|0.38<br>(9.65)<br>~~yy~~<br>~~fp~~|
|100<br>ef]|3.01<br>(76.45)<br>ef]fof|1.00<br>(25.40)<br>fof|1.26<br>(32.00)<br>fof~~fp~~|0.57<br>(14.48)<br>~~fp~~|0.06<br>(1.60)<br>~~fpfp~~|0.58<br>(14.78)<br>~~fp~~|0.38<br>(9.65)<br>~~fp~~|
## **Time-Current Characteristic Curves–Average Melt**
**Data Sheet: 9000 (fuses) and 9007 (holders)**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**27**
**Low Voltage, Branch Circuit Rated Fuses**
## **UPS & Critical Application Fast-Acting CUBEFuse[™] Finger-safe Fuse**
## **FCF Class CF Fuse**
## **Features and Product Benefits**
- The world’s first finger-safe power fuse system.
- Smallest footprint of any class fuse including Class J, CC, T and RK.
- Class CF meets Class J fast-acting electrical performance requirements.
- Faster response to damaging faults to help reduce destructive thermal and magnetic forces.
- True fast-acting fuse construction.
- High interrupting rating to safely interrupt faults up to 300kA.
- No venting of arc or molten metal and gases during opening.
## Catalog Symbol: FCF_RN
- Low let-through currents under fault conditions.
Fast-Acting Fuse: 4 minutes maximum clearing time at 200% rated current for 1 to 30A fuse
6 minutes maximum clearing time at 200% rated current for 35 to 60A fuse
**Dimensions:** See Dimensions illustration.
**Poles:** 1-pole (gangable)
**Ratings:**
Volts — 600Vac (or less)
|**Fuse Catalog Numbers Non**|**Fuse Catalog Numbers Non**|**Fuse Catalog Numbers Non-Indicating (Amps)**|**Indicating (Amps)**|
|---|---|---|---|
|FCF1RN|FCF20RN|FCF45RN|FCF90RN|
|FCF3RN|FCF25RN|FCF50RN|FCF100RN|
|FCF6RN|FCF30RN|FCF60RN|–|
|FCF10RN|FCF35RN|FCF70RN|–|
|FCF15RN|FCF40RN|FCF80RN|–|
— 300Vdc (or less)
Amps — 1-100A
IR — 300kA RMS Sym. (UL)
- 200kA RMS Sym. (CSA)
- 50kA DC (UL & CSA)
**Agency Information:**
- UL Listed Fuse: Guide JFHR, File E4273
- CSA Certified Fuse: Class 1422- 02, File 53787
- CE compliance for the European Union low voltage directive
## **Other Ratings/Specifications:**
Watts Loss at rated current: FCF15RN: 3.48W
FCF30RN: 5.45W FCF60RN: 7.27W
Scan this tag to get the latest product information for the New FCF CUBEFuse.
## **Operating and Storage Temperature Range:**
- -40 to 80°C
## **Material Specifications:**
- Case: Glass filled PES (Polyethersulfone)
- Terminals: Copper alloy
- Terminal plating: Electroless tin
## **Carton Quantity and Weight**
|Amp<br>Rating|Carton<br>Qty.|Weight Per Carton|Weight Per Carton|
|---|---|---|---|
|||lbs|kg|
|FCF-1-30A|12|1.39|0.63|
|FCF-35-60A|12|1.42|0.65|
|FCF-70-100A|6|1.74|0.79|
## **Recommended Fuse Holders For Class CF Fuses**
• See pages 32 and 33
## **Data Sheet: 2147**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**28**
**Low Voltage, Branch Circuit Rated Fuses**
## **UPS & Critical Application Fast-Acting CUBEFuse[™] Finger-safe Fuse**
## **FCF_RN Dimensions – in (mm)**
**Current Limitation Curves**
**B** 100,000 **100A** 10,000 **60A 30A 15A** 1,000 **A** 100 **PROSPECTIVE SHORT CIRCUIT CURRENT (SYMMETRICAL RMS AMPS)** ~~Ee~~ **Time-Current Characteristic Curves–Average Melt 1000** Fuse Dimensions - in (mm) Amps A B C D E F G 1.88 0.75 1.00 0.23 0.04 0.63 0.28 1-15 (47.75) (19.05) (25.40) (5.84) (1.02) (15.93) (7.11) **100** 1.88 0.75 1.00 0.31 0.04 0.63 0.28 ~~coaeeeee~~ 20 e ~~ee!~~ (47.75) (19.05) (25.40) (7.87) (1.02) (15.93) (7.11) 1.88 0.75 1.00 0.31 0.04 0.63 0.28 25-30 (47.75) (19.05) (25.40) (7.87) (1.02) (15.93) (7.11) 2.13 1.00 1.13 0.36 0.04 0.63 0.38 **10** 35-40 ~~FERRERS~~ (54.10) (25.40) (28.58) (9.10) (1.02) (15.93) (9.65) ~~LH|\\\eee~~ 2.13 1.00 1.13 0.44 0.04 0.63 0.38 45-50 (54.10) (25.40) (28.58) (11.13) (1.02) (15.93) (9.65) 2.13 1.00 1.13 0.44 0.04 0.63 0.38 60 (54.10) (25.40) (28.58) (11.13) (1.02) (15.93) (9.65) **1** 3.01 1.00 1.26 0.49 0.06 0.58 0.38 ~~FEEEEEEA~~ 70 ~~AAT~~ (76.45) (25.40) (32.00) (12.45) (1.60) (14.78) (9.65) 3.01 1.00 1.26 0.49 0.06 0.58 0.38 80-90 (76.45) (25.40) (32.00) (12.45) (1.60) (14.78) (9.65) 100 3.01 1.00 1.26 0.57 0.06 0.58 0.38 **0.1** (76.45) (25.40) (32.00) (14.48) (1.60) (14.78) (9.65) ~~SSE UA~~
**==> picture [218 x 131] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>0.1<br>UA<br>0.01 AAA<br>CURRENT IN AMPS<br>1 10 100 1,000 10,000<br>**----- End of picture text -----**<br>
**Data Sheet: 2147**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**29**
**Low Voltage, Branch Circuit Rated Fuses**
## **– Wind Fast-Acting CUBEFuse[™] Finger-safe Fuse**
## **WCF Class CF Fuse**
## **Features and Product Benefits**
- Maximize uptime and reliability using fuses designed and listed to UL 248-1.
- Minimize chances of equipment failure and personnel injury when using full range fuses having the industry’s fastest response time to low-magnitude faults.
- Maximize return on investment with fuses proven to withstand harsh temperatures.
- Minimize design time, operating outage time and replacement cost with fuses qualified in excessively changing enviromental conditions.
- Simplify compatibility with readily available industry standard Class CF holders.
## Catalog Symbol: WCF_RN
Description: Finger-safe, fast-acting CUBEFuse for wind power generation.
Electrical Characteristics: Maximum clearing time at 200% rated current:
- 4 Minutes for 1 to 30A fuses
- 6 Minutes for 35 to 60A fuses
- Temperature Derating: Designed to maximize rated capacity in elevated environmental temperatures.
- Overload Protection: Proven to clear faults faster than the UL requirement.
- Power Loss: Minimal energy consumption leading to increased efficiency.
- 8 Minutes for 70 to 100A fuses
## Ratings:
Volts — 690Vac
Amps — 1-100A IR — 50kA AC (1-60A) IR — 30kA AC (70-100A)
## Agency Information:
## Catalog Numbers (amp rating)
**==> picture [227 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Non-Indicating Wind CUBEFuse|
|WCF1RN|WCF15RN|WCF35RN|WCF60RN|WCF100RN|
|WCF3RN|WCF20RN|WCF40RN|WCF70RN|—|
|WCF6RN|WCF25RN|WCF45RN|WCF80RN|—|
|WCF10RN|WCF30RN|WCF50RN|WCF90RN|—|
**----- End of picture text -----**<br>
- UL Recognized Fuse: Guide JFHR, File E56412
- cURus component certified C22.2
- CE compliance for the European Union low voltage directive
## Other Ratings/Specifications:
Watts Loss at Rated Current: WCF15RN: 3.48W WCF30RN: 5.45W WCF60RN: 7.27W WCF100RN: 11.50W
## Carton Quantity and Weight
**==> picture [142 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Amp|Carton|Weight Per Carton|
|Rating|Qty.|lbs|kg|
|WCF1-30A|12|1.39|0.63|
|WCF35-60A|12|1.42|0.65|
|WCF70-100A|6|1.74|0.79|
**----- End of picture text -----**<br>
## Operating and Storage Temperature Range: -40 to 90°C
## Material Specifications:
- Case: Glass filled PES (Polyethersulfone)
- Terminals: Copper alloy
- Terminal plating: Electroless tin
## Installation:
Fits 690V WCF holders as listed in the table
Application:
- Wind Systems:
- Transformer protection
- Pitch and speed control
Scan this tag to get the latest product information for the New WCF CUBEFuse.
- Turbine HVAC and lighting
## **Recommended Fuse Holders For Class CF Fuses**
- See pages 32 and 33
**Data Sheet: 9009**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**30**
**Low Voltage, Branch Circuit Rated Fuses**
## **– Wind Fast-Acting CUBEFuse[™] Finger-safe Fuse**
## **WCF_RN Dimensions – in (mm)**
|100<br>1,000<br>10,000<br>100<br>1,000<br>10,000<br>100,000<br>**INSTANTANEOUS PEAK LET THRU CURRENT IN AMPS**<br>**PROSPECTIVE SHORT CIRCUIT CURRENT**<br>**SYMMETRICAL RMS AMPS**<br>**A**<br>Fuse<br>Dimensions - in (mm)<br>Amps<br>A<br>B<br>C<br>D<br>E<br>F<br>G<br>35-40<br>2.13<br>1.00<br>1.13<br>0.36<br>0.04<br>0.63<br>0.38<br>(54.10)<br>(25.40)<br>(28.58)<br>(9.10)<br>(1.02)<br>(15.93)<br>(9.65)<br>45-50<br>2.13<br>1.00<br>1.13<br>0.44<br>0.04<br>0.63<br>0.38<br>(54.10)<br>(25.40)<br>(28.58)<br>(11.13)<br>(1.02)<br>(15.93)<br>(9.65)<br>60<br>2.13<br>1.00<br>1.13<br>0.44<br>0.04<br>0.63<br>0.38<br>(54.10)<br>(25.40)<br>(28.58)<br>(11.13)<br>(1.02)<br>(15.93)<br>(9.65)<br>70<br>3.01<br>1.00<br>1.26<br>0.49<br>0.06<br>0.58<br>0.38<br>(76.45)<br>(25.40)<br>(32.00)<br>(12.45)<br>(1.60)<br>(14.78)<br>(9.65)<br>80-90<br>3.01<br>1.00<br>1.26<br>0.49<br>0.06<br>0.58<br>0.38<br>(76.45)<br>(25.40)<br>(32.00)<br>(12.45)<br>(1.60)<br>(14.78)<br>(9.65)<br>100<br>3.01<br>1.00<br>1.26<br>0.57<br>0.06<br>0.58<br>0.38<br>(76.45)<br>(25.40)<br>(32.00)<br>(14.48)<br>(1.60)<br>(14.78)<br>(9.65)<br>Time-Current Characteristic Curves–Average Melt<br>**100A**<br>**60A**<br>**10A**<br>**15A**<br>**20A**<br>**30A**<br>**40A**<br>**50A**<br>**1A**<br>**3A**<br>**6A**<br>**0.01**<br>**0.1**<br>**1**<br>**10**<br>**100**<br>**1000**<br>**1**<br>**10**<br>**100**<br>**1,000**<br>**10,000**<br>**TIME IN SECONDS**<br>**CURRENT IN AMPS**<br>~~sii~~<br>~~sue cia~~<br>i<br>~~ee~~<br>~~SSeS LIN~~<br>~~ah ee~~<br>~~ore~~<br>~~ee~~<br>~~WI~~<br>~~AA~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|
||~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|
||~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|
||~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue~~|~~sii~~<br>~~sue cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|~~sii~~<br>~~cia~~|
||||||||~~sue~~|~~sue~~|~~sue~~|~~sue~~|~~sue~~|~~sue cia~~|~~cia~~|~~cia~~|~~cia~~|~~cia~~|~~cia~~|~~cia~~|~~cia~~|~~cia~~|
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|
||~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|
||~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|
||~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|
||~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|
||~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|
**Data Sheet: 2155**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**31**
**Low Voltage, Branch Circuit Rated Fuses**
## **CUBEFuse[™] Finger-safe Fuse Holder System**
## **CUBEFuse Fuse Holder**
## **Catalog Symbols:**
## **Ampacity**
**600V 690V (Wind) (holds any CUBEFuse)** TCFH30N TCFH30NW (1-30A) TCFH60N TCFH60NW (1-60A) TCFH100N TCFH100NW (1-100A)
**Construction:** Finger-safe
**Mounting:** 35mm DIN-Rail or panel mount
## **Ratings:**
Volts: 600V (UL, CSA) 690V (cURus - Wind version) Withstand Rating: 300kA RMS Sym. (UL) 200kA RMS Sym. (CSA) 100kA DC (UL & CSA) 50kA AC (cURus, 1-60A Wind version)
## **Agency Information:**
- UL Listed Fuse Holder: Guide IZLT, File E14853
- CSA Certified Fuse Holder: Class 6225-01, File 47235
- cURus component Certified
- CE compliance for the European Union low voltage directive
- **Operating and Storage Temperature Range:** -40 to 80°C
## **Material Specifications:**
- Holder case: Glass filled PBT
- Interface clips: Copper alloy
- Interface clip plating: Tin
- Terminals: Steel
- DIN Rail spring: Stainless steel
## **CUBEFuse™ Holder Applications**
|**CUBEFuse**<br>**Holder**<br>**Catalog**<br>**Number**|**Volts**|**CUBEFuse Type and Ampacity Range Per CUBEFuse Holder**<br>**Non-Indicating**<br>**Indicating**<br>**Time-Delay**<br>**Time-Delay**<br>**Fast-Acting**<br>**Photovoltaic**<br>**Wind**<br>**TCF_RN**<br>**TCF_**<br>**FCF_RN**<br>**PVCF_RN**<br>**WCF_RN**<br>1-30<br>6-30<br>1-30<br>—<br>—<br>1-60<br>6-60<br>1-60<br>35-60<br>—<br>1-100<br>6-100<br>1-100<br>35-100<br>—<br>—<br>—<br>—<br>—<br>1-30<br>—<br>—<br>—<br>—<br>1-60<br>—<br>—<br>—<br>—<br>1-100|**CUBEFuse Type and Ampacity Range Per CUBEFuse Holder**<br>**Non-Indicating**<br>**Indicating**<br>**Time-Delay**<br>**Time-Delay**<br>**Fast-Acting**<br>**Photovoltaic**<br>**Wind**<br>**TCF_RN**<br>**TCF_**<br>**FCF_RN**<br>**PVCF_RN**<br>**WCF_RN**<br>1-30<br>6-30<br>1-30<br>—<br>—<br>1-60<br>6-60<br>1-60<br>35-60<br>—<br>1-100<br>6-100<br>1-100<br>35-100<br>—<br>—<br>—<br>—<br>—<br>1-30<br>—<br>—<br>—<br>—<br>1-60<br>—<br>—<br>—<br>—<br>1-100|**CUBEFuse Type and Ampacity Range Per CUBEFuse Holder**<br>**Non-Indicating**<br>**Indicating**<br>**Time-Delay**<br>**Time-Delay**<br>**Fast-Acting**<br>**Photovoltaic**<br>**Wind**<br>**TCF_RN**<br>**TCF_**<br>**FCF_RN**<br>**PVCF_RN**<br>**WCF_RN**<br>1-30<br>6-30<br>1-30<br>—<br>—<br>1-60<br>6-60<br>1-60<br>35-60<br>—<br>1-100<br>6-100<br>1-100<br>35-100<br>—<br>—<br>—<br>—<br>—<br>1-30<br>—<br>—<br>—<br>—<br>1-60<br>—<br>—<br>—<br>—<br>1-100|**CUBEFuse Type and Ampacity Range Per CUBEFuse Holder**<br>**Non-Indicating**<br>**Indicating**<br>**Time-Delay**<br>**Time-Delay**<br>**Fast-Acting**<br>**Photovoltaic**<br>**Wind**<br>**TCF_RN**<br>**TCF_**<br>**FCF_RN**<br>**PVCF_RN**<br>**WCF_RN**<br>1-30<br>6-30<br>1-30<br>—<br>—<br>1-60<br>6-60<br>1-60<br>35-60<br>—<br>1-100<br>6-100<br>1-100<br>35-100<br>—<br>—<br>—<br>—<br>—<br>1-30<br>—<br>—<br>—<br>—<br>1-60<br>—<br>—<br>—<br>—<br>1-100|
|---|---|---|---|---|---|
|||**Non-Indicating**<br>**Time-Delay**<br>**TCF_RN**|**Indicating**<br>**Time-Delay**<br>**TCF_**|**Fast-Acting**<br>**FCF_RN**|**Photovoltaic**<br>**PVCF_RN**|
|TCFH30N|600|1-30|6-30|1-30|—|
|TCFH60N|600|1-60|6-60|1-60|35-60|
|TCFH100N|600|1-100|6-100|1-100|35-100|
|TCFH30NW|690|—|—|—|—|
|TCFH60NW|690|—|—|—|—|
|TCFH100NW|690|—|—|—|—|
## **Terminal Torque Ratings by Conductor and Holder Size (75°C Cu only)**
|**TCFH30N / TCFH30NW**|**TCFH30N / TCFH30NW**|**TCFH60N / TCFH60NW**|**TCFH60N / TCFH60NW**|**TCFH100N / TCFH100NW**|**TCFH100N / TCFH100NW**|
|---|---|---|---|---|---|
|**Single**|**Dual**|**Single**|**Dual**|**Single**|**Dual**|
|10-8AWG 25Lb-In|18-10AWG 25Lb-In*|14-10AWG 20Lb-In|18-10AWG 20Lb-In|18-10AWG 25Lb-In**|6AWG 45Lb-In†|
|18-12AWG 20Lb-In||8-4AWG 35Lb-In|8-6AWG 35Lb-In|8-1AWG 40Lb-In†||
- 18-10AWG Stranded, 14-18AWG solid
- ** Solid and stranded
- Stranded
**Data Sheet: 9007**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**32**
**Low Voltage, Branch Circuit Rated Fuses** get
## **CUBEFuse[™] Finger-safe Fuse Holder System**
## **Diamensions for CUBEFuse Fuse Holder**
## **CUBEFuse™ Holder Catalog Numbers**
|**Catalog**<br>**Number**|**CUBEFuse**<br>**Amp Range**|**Wire Range (Cu/AWG)**|**Wire Range (Cu/AWG)**|**Wire Range (Cu/AWG)**|**Wire Range (Cu/AWG)**|**Wire Range (Cu/AWG)**|**Wire Range (Cu/AWG)**|**Wire Range (Cu/AWG)**|
|---|---|---|---|---|---|---|---|---|
|||**Wire Range (Cu/AWG)**<br>**Single**|**Wire Range (Cu/AWG)**<br>**Dual**|**H**|**Dimensions - in (mm)**<br>**I**|**Dimensions - in (mm)**<br>**J**|**Dimensions - in (mm)**<br>**K**|**Dimensions - in (mm)**<br>**L**|
|TCFH30N<br>TCFH30NW|1-30|14-8|14-10|2.30<br>(58.5)|0.76<br> (19.37)|1.36<br> (34.24)|0.15<br> (3.76)|—<br>—|
|TCFH60N<br>TCFH60NW|1-60|14-4|10-6|2.60<br>(66.12)|1.03<br> (26.23)|1.60<br> (40.64)|0.17<br> (4.34)|—<br>—|
|TCFH100N<br>TCFH100NW|1-100|10-1|6|2.91<br>(73.81)|1.05<br> (26.74)|2.01<br> (50.93)|0.15<br> (3.81)|0.80<br> (20.39)|
**Data Sheet: 9007**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**33**
**Low Voltage, Branch Circuit Rated Fuses**
## **Time-delay Fuses**
## **SC Class G**
## **Time-Current Characteristic Curves—Average Melt**
## **Specifications**
**Description:** Fast-acting ([1] ⁄2-6A), time-delay (7-60A)fuse. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts — 600Vac ([1] ⁄2-20A) — 480Vac (25-60A) — 170Vdc ([1] ⁄2-20A) — 300Vdc (30 & 60A only)
Amps —[1] ⁄2-60A
IR — 100kA RMS Sym. — 10kA DC
## **Agency Information:** CE, Std. 248-
5, Class G, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-01, File 53787.
## **Features and Benefits**
- Current limiting for component protection, providing Class G energy-limitation for branch circuit protection.
- 100kA interrupting rating provides cost-effective branch circuit fusing.
- Variations in length help prevent overfusing.
## **Typical Applications**
- Fusible Branch Panelboards
- HVAC Branch Circuit Protection
## **Catalog Numbers (Amps)**
|SC-1⁄2|SC-2-1⁄2|SC-6|SC-12|SC-30|SC-50|
|---|---|---|---|---|---|
|SC-1<br>SC-1-1⁄2|SC-3<br>SC-4|SC-7<br>SC-8|SC-15<br>SC-20|SC-35<br>SC-40|SC-60|
|SC-2|SC-5|SC-10|SC-25|SC-45||
## **Dimensions -in (mm)**
|**Fuse Amps**<br>**Length**<br>**Diameter**<br>SC-1⁄2 to -15<br>1.31(33.3)<br>0.41”(10.4)<br>SC-20<br>1.41(35.8)<br>0.41”(10.4)<br>SC-25 to -30<br>1.62(41.2)<br>0.41”(10.4)<br>SC-35 to -60<br>2.25(57.1)<br>0.41”(10.4)<br>~~a~~|||A<br>(Length)<br>0.41"<br>(10.41mm)|
|---|---|---|---|
## **Current Limitation Curves**
**==> picture [251 x 191] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>10,000 fo 60<br>30<br>20<br>15<br>ett et<br>1,000 (Lee<br>La<br>Lo<br>A<br>100<br>RMS SYMMETRICAL CURRENTS IN AMPS<br>A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)<br>AMP RATING<br>CURRENT IN AMPS<br>INSTANTANEOUS PEAK LET-THROUGH<br>100 1,000 10,000 100,000<br>**----- End of picture text -----**<br>
**Recommended Fuse Holders & Blocks For Class G Fuses** • See page 18
**Data Sheet: 1024**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**34**
**Low Voltage, Branch Circuit Rated Fuses**
## **Low-Peak[™] Dual-element, Time-delay Fuses**
## **LPJ_SP Class J**
## _**Available With**_
## _**Indication**_
## **Specifications Description:**
Dual-element, time-delay fuse;
10 seconds (minimum) at 500% rated amps. Now available with optional indication on select ratings (see Catalog Numbers table).
**Dimensions:** See page 11 for Class J dimensions. **Ratings:**
Volts — 600Vac (or less)
— 300Vdc (or less)
Amps — 1-600A
IR — 300kA RMS Sym.
- 100kA DC
**Agency Information:** CE, UL Listed - Special Purpose*, Guide JFHR, File E56412, CSA Certified (200k AIR) Class J per CSA-22.2 No. 248.8, Class 1422-02, File 53787.
## **Features and Benefits**
- Separate overload and short-circuit elements provide time delay for sizing of high inrush loads linked with Class J current limitation.
- Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit.
- Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer.
## **Typical Applications**
- Power Panelboards
- Branch Circuit Breaker Panelboard Mains
- Machinery Disconnects
|•|Industrial Control<br>**Catalog Numbers (Amps)**<br>LPJ-1SP<br>LPJ-4-<br>1⁄2SP<br>LPJ-25SP**<br>LPJ-125SP**<br>LPJ-1-<br>1⁄4SP<br>LPJ-5SP<br>LPJ-30SP**<br>LPJ-150SP**<br>LPJ-1-<br>6⁄10SP<br>LPJ-5-<br>6⁄10SP<br>LPJ-35SP**<br>LPJ-175SP**<br>LPJ-1-<br>8⁄10SP<br>LPJ-6SP**<br>LPJ-40SP**<br>LPJ-200SP**<br>LPJ-2SP<br>LPJ-7SP**<br>LPJ-45SP**<br>LPJ-225SP**<br>LPJ-2-<br>1⁄4SP<br>LPJ-8SP**<br>LPJ-50SP**<br>LPJ-250SP**<br>LPJ-2-<br>1⁄2SP<br>LPJ-9SP**<br>LPJ-60SP**<br>LPJ-300SP**<br>LPJ-2-<br>8⁄10SP<br>LPJ-10SP**<br>LPJ-70SP**<br>LPJ-350SP**<br>LPJ-3SP<br>LPJ-12SP**<br>LPJ-80SP**<br>LPJ-400SP**<br>~~Ce~~<br>~~Oe~~<br>~~BS~~|Industrial Control<br>**Catalog Numbers (Amps)**<br>LPJ-1SP<br>LPJ-4-<br>1⁄2SP<br>LPJ-25SP**<br>LPJ-125SP**<br>LPJ-1-<br>1⁄4SP<br>LPJ-5SP<br>LPJ-30SP**<br>LPJ-150SP**<br>LPJ-1-<br>6⁄10SP<br>LPJ-5-<br>6⁄10SP<br>LPJ-35SP**<br>LPJ-175SP**<br>LPJ-1-<br>8⁄10SP<br>LPJ-6SP**<br>LPJ-40SP**<br>LPJ-200SP**<br>LPJ-2SP<br>LPJ-7SP**<br>LPJ-45SP**<br>LPJ-225SP**<br>LPJ-2-<br>1⁄4SP<br>LPJ-8SP**<br>LPJ-50SP**<br>LPJ-250SP**<br>LPJ-2-<br>1⁄2SP<br>LPJ-9SP**<br>LPJ-60SP**<br>LPJ-300SP**<br>LPJ-2-<br>8⁄10SP<br>LPJ-10SP**<br>LPJ-70SP**<br>LPJ-350SP**<br>LPJ-3SP<br>LPJ-12SP**<br>LPJ-80SP**<br>LPJ-400SP**<br>~~Ce~~<br>~~Oe~~<br>~~BS~~|Industrial Control<br>**Catalog Numbers (Amps)**<br>LPJ-1SP<br>LPJ-4-<br>1⁄2SP<br>LPJ-25SP**<br>LPJ-125SP**<br>LPJ-1-<br>1⁄4SP<br>LPJ-5SP<br>LPJ-30SP**<br>LPJ-150SP**<br>LPJ-1-<br>6⁄10SP<br>LPJ-5-<br>6⁄10SP<br>LPJ-35SP**<br>LPJ-175SP**<br>LPJ-1-<br>8⁄10SP<br>LPJ-6SP**<br>LPJ-40SP**<br>LPJ-200SP**<br>LPJ-2SP<br>LPJ-7SP**<br>LPJ-45SP**<br>LPJ-225SP**<br>LPJ-2-<br>1⁄4SP<br>LPJ-8SP**<br>LPJ-50SP**<br>LPJ-250SP**<br>LPJ-2-<br>1⁄2SP<br>LPJ-9SP**<br>LPJ-60SP**<br>LPJ-300SP**<br>LPJ-2-<br>8⁄10SP<br>LPJ-10SP**<br>LPJ-70SP**<br>LPJ-350SP**<br>LPJ-3SP<br>LPJ-12SP**<br>LPJ-80SP**<br>LPJ-400SP**<br>~~Ce~~<br>~~Oe~~<br>~~BS~~|
|---|---|---|---|
||LPJ-3-2⁄10SP<br>LPJ-15SP**|LPJ-90SP**|LPJ-450SP**|
||LPJ-3-1⁄2SP<br>LPJ-17-1⁄2SP**|LPJ-100SP**|LPJ-500SP**|
||LPJ-4SP<br>LPJ-20SP**|LPJ-110SP**|LPJ-600SP**|
## **Time-Current Characteristic Curves–Average Melt**
**==> picture [250 x 532] intentionally omitted <==**
**----- Start of picture text -----**<br>
AMP<br>RATING<br>300<br>200<br>On Weer ee ee | |<br>100<br>VON AV AA YL AAV YY<br>10<br>VOLO<br>1<br>EE<br>Seereeet a eee Oa tee VAa<br>NYE<br>.1<br>Pe AA<br>.01 EL<br>CURRENT IN AMPS<br>Current Limitation Curves<br>LPJ Current Limitation Curves<br>B<br>100,000<br>600A<br>400A<br>200A<br>100A<br>a<br>60A<br>10,000<br>30A<br>15A<br>eer<br>1,000<br>A for<br>100 PLEINVT TT TEETNETTI)<br>PROSPECTIVE SHORT-CIRCUIT CURRENT<br>SYMMETRICAL RMS AMPS<br>1A 3A 6A 10A 15A 30A 60A 80A 100A 125A 200A 250A 400A 600A<br>TIME IN SECONDS<br>1 10 100 1,000 10,000<br>TING<br>AMP RA<br>INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS<br>100 1,000 10,000 100,000 200,000 300,000<br>**----- End of picture text -----**<br>
*Meets all performance requirements of UL Standard 248-8 for Class J fuses. **Available with optional permanent replace fuse indication. To order, place “I” at end of catalog number. Example: LPJ-6SPI. Available with silver plated terminals. Add SP/ in front of Catalog Number.
## **Data Sheets: 1006 (0-60) and 1007 (70-600)**
## **With indication 1062 (6-60) and 1063 (70-600)**
## **Recommended Fuse Holders & Blocks For Class J Fuses**
• See page 20
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**35**
**Low Voltage, Branch Circuit Rated Fuses**
## **Limitron[™] Fast-acting Fuses**
## **JKS Class J**
## **Specifications**
**Description:** Fast-acting, current-limiting fuse.
**Dimensions:** See page 15 for Class J dimensions.
**Ratings:**
Volts — 600Vac (or less) Amps — 1-600A IR — 200kA RMS Sym.
**Agency Information:** CE, Std. 248-8, Class J, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787.
## **Features and Benefits**
- Current limitation for non-inductive circuits provides Class J current-limiting response to maximum ground fault and short-circuit conditions.
- 200kA interrupting rating provides high ratings at all circuit locations.
- Economical solutions for high-fault circuits.
## **Typical Applications**
- Power Panelboards
- Machinery Disconnects
## **Catalog Numbers (Amps)**
|**Catalog Numbers (Amps)g Numbers (Amps) Numbers (Amps)(Amps)Amps)ps)s))**|||
|---|---|---|
|JKS-1<br>JKS-15<br>JKS-2<br>JKS-20|JKS-70<br>JKS-80|JKS-225<br>JKS-250|
|JKS-3<br>JKS-25|JKS-90|JKS-300|
|JKS-4<br>JKS-30|JKS-100|JKS-350|
|JKS-5<br>JKS-35<br>JKS-110<br>JKS-400<br>JKS-6<br>JKS-40<br>JKS-125<br>JKS-450<br>JKS-8<br>JKS-45<br>JKS-150<br>JKS-500<br>JKS-10<br>JKS-50<br>JKS-175<br>JKS-600<br>JKS-12<br>JKS-60<br>JKS-200<br>~~a~~<br>~~——~~|||
For superior electrical protection, Bussmann recommends upgrading JKS fuse applications to Low-Peak LPJ fuses See page 35.
## **Recommended Fuse Holders & Blocks For Class J Fuses**
- See page 20
## **Data Sheet: 1026 (1-60) and 1027 (70-600)**
## **Time-Current Characteristic Curves—Average Melt**
**==> picture [229 x 612] intentionally omitted <==**
**----- Start of picture text -----**<br>
AMP<br>RATING<br>300<br>JKS<br>100<br>TINATALINN TTT<br>JVoo\V\ yyy<br>10 |\Vo\\\\\\\yyy<br>ill ane Vn nn<br>1 HATH A<br>AUN [NIN]<br>stadia een sa i oe weet<br>.1 RETANIAee ee ee<br>JN NLA AAT<br>FH I<br>PE TEATI<br>.01 TIHIE [TATA] TATIIRATAUATNNIA<br>CURRENT IN AMPS<br>Current Limitation Curves<br>B<br>400,000<br>a |<br>100,000<br>IN Et<br>600<br>400<br>200<br>HHH eat 100<br>60<br>10,000<br>30<br>[Area eat<br>A<br>pee HT<br>ae<br>1,000 lll<br>RMS SYMMETRICAL CURRENTS IN AMPS<br>A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)<br>30A 60A 100A 200A 400A 600A<br>TIME IN SECONDS<br>40 100 1,000 10,000<br>AMP RATING<br>INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS<br>1,000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
## **Current Limitation Curves**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**36**
**Low Voltage, Branch Circuit Rated Fuses**
## **One-time General Purpose Fuses**
**NON (250Vac/125Vdc) Class K5 & H NOS (600Vac) Class K5 & H**
## **NOS (600Vac) Catalog Numbers (Amps)**
**==> picture [296 x 270] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|NOS-1|NOS-12|NOS-70|NOS-200|
|NOS-2|NOS-15|NOS-75|NOS-225|
|NOS-3|NOS-20|NOS-80|NOS-250|
|NOS-4|NOS-25|NOS-90|NOS-300|
|NOS-5|NOS-30|NOS-100|NOS-350|
|NOS-6|NOS-35|NOS-110|NOS-400|
|NOS-7|NOS-40|NOS-125|NOS-450|
|NOS-8|NOS-45|NOS-150|NOS-500|
|NOS-9|NOS-50|NOS-175|NOS-600|
|———————|
|NOS-10|NOS-60|
|Recommended Fuse Reducers|
|250V|600V|
|Fuse|Clip|Catalog|Fuse|Clip|Catalog|
|Amp|Amp|Number|Amp|Amp|Number|
|Size|Size|(Pair)|Size|Size|(Pair)|
|30|60|NO.263|30|60|NO.663|
|30|100|NO.213|30|100|NO.216|
|60|100|NO.216|60|100|NO.616|
|60|200|NO.226|60|200|NO.626|
|100|200|NO.2621|100|200|NO.2621|
|100|400|NO.2641|100|400|NO.2641|
|200|400|NO.2642|200|400|NO.2642|
|100|600|NO.2661|100|600|NO.2661|
|200|600|NO.2662|200|600|NO.2662|
|400|600|NO.2664|400|600|NO.2664|
**----- End of picture text -----**<br>
## **Specifications**
**Description:** General purpose, non-current-limiting fuses. **Dimensions:** See page 15 for dimensions.
## **Ratings:**
Volts — **NON:**
- 250Vac
- 125Vdc (0-100A)
— **NOS:**
- 600Vac
- Amps —[1] ⁄8-600A
- IR — 50kA RMS Sym. (NON & NOS Class K5 0-60A)
- 10kA RMS Sym. (NON & NOS Class H65-600A)
- 50kA @ 125Vdc (NON Class K5 0-60A)
- 10kA @ 125Vdc (NON Class H 65-100A)
**Agency Information:** CE, UL Listed – 250V: Class K5 (0-60A), Std. 248-9, Class H (65-600A), Std. 248-6, (125Vdc: NON 0-100), 600V: Class K5 (0-60A), Std. 248-9, Class H (70-600A), Std. 248-6, Guide JDDZ, File E4273, CSA Certified – 250V: (0-12, 65-600)†, 600V: (0-600), Class 1421-01, File 53787.
† _For CSA Certified 15-60A Ratings, see PON Data Sheet 4126_
## **Features and Benefits**
- Original fuse providing circuit protection.
## **Typical Applications**
- Light Duty Circuit Locations
## **NON (250Vac) Catalog Numbers (Amps)**
**==> picture [222 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|NON-|[1]|⁄8|NON-5|NON-40|NON-175|
|NON-|[1]|⁄2|NON-6|NON-45|NON-200|
|NON-|[3]|⁄4|NON-6-|[1]|⁄4|NON-50|NON-225|
|NON-|[8]|⁄10|NON-7|NON-60|NON-250|
|NON-1|NON-8|NON-65|NON-300|
|NON-1-|[1]|⁄4|NON-9|NON-70|NON-350|
|NON-1-|[1]|⁄2|NON-10|NON-75|NON-400|
|NON-1-|[6]|⁄10|NON-12|NON-80|NON-450|
|NON-2|NON-15|NON-90|NON-500|
|NON-2-|[1]|⁄2|NON-20|NON-100|NON-600|
|NON-3|NON-25|NON-110|
|NON-3-|[2]|⁄10|NON-30|NON-125|
|NON-4|NON-35|NON-150|
**----- End of picture text -----**<br>
For superior electrical protection, Bussmann recommends upgrading NON (250Vac) and NOS (600Vac) fuse applications to Low-Peak LPN-RK (250Vac) and LPS-RK (600Vac) fuses See page 41.
## **Recommended Fuse Holders & Blocks For Class K5 & H 250V & 600V Fuses**
• See page 18
**Data Sheet: 1030**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**37**
**Low Voltage, Branch Circuit Rated Fuses**
## **Low-Peak[™] Time-delay Fuses**
## **KRP-C_SP Class L**
## **Specifications**
**Description:** Time-delay fuse – 4 seconds (minimum) at 500% rated amps. **Dimensions:** See page 16 for Class L dimensions.
## **Ratings:**
## **Catalog Numbers (Amps)**
KRP-C-601SP KRP-C-1000SP KRP-C-1800SP KRP-C-3500SP KRP-C-650SP KRP-C-1100SP KRP-C-1900SP KRP-C-4000SP KRP-C-700SP KRP-C-1200SP KRP-C-2000SP KRP-C-4500SP KRP-C-750SP KRP-C-1350SP KRP-C-2001SP KRP-C-5000SP KRP-C-800SP KRP-C-1400SP KRP-C-2400SP KRP-C-6000SP KRP-C-801SP KRP-C-1500SP KRP-C-2500SP KRP-C-900SP KRP-C-1600SP KRP-C-3000SP
Volts — 600Vac (or less) — 300Vdc (601-2000A) Amps — 601-6000A (use KRP-CL for current ratings under 601A)
IR — 300kA RMS Sym. — 100kA DC
**Agency Information:** CE, UL ListedSpecial Purpose (meets all performance requirements of UL Standard 248-10 for Class L fuses),Guide JFHR, File E56412, CSA Certified (200k AIR), Class 1422-02, File 53787, Class L per CSA C22.2, No. 248.10.
## **Features and Benefits**
- Time-delay of four seconds at five times rating allows closer sizing on large motor loads combined with Class L current limitation.
- Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit.
- Interrupting rating of 300kA RMS symmetrical provides adequate ratings without obsolescence for all electrical systems, big or small.
- Quality construction, using high-grade materials, provides lower watts loss and operating temperatures with superior arc quenching during current-limiting action.
## **Typical Applications**
- Large Distribution Switchboards
- Power Panelboards
- Large Machinery Disconnects
• See page 19
**Recommended Fuse Holders & Blocks For Class L Fuses**
**Data Sheets: 1008 and 1009**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**38**
**Low Voltage, Branch Circuit Rated Fuses**
## **Low-Peak[™] Time-delay Fuses**
**Time-Current Characteristic Curves—Average Melt**
## **Current Limitation Curves**
**==> picture [519 x 395] intentionally omitted <==**
**----- Start of picture text -----**<br>
1000,000<br>AMP B<br>RA TING<br>300<br>6,000A<br>5,000A<br>4,000A<br>3,000A<br>100 2,500A<br>2,000A<br>100,000 1,600A<br>1,200A<br>800A<br>601A<br>10<br>10,000<br>A<br>1<br>1,000<br>PROSPECITVE SHORT-CIRCUIT CURRENT<br>SYMMETRICAL RMS AMPS<br>.1<br>.01<br>Data Sheets: 1008 and 1009<br>CURRENT IN AMPS<br>800A 1200A 1600A 2000A 2500A 3000A 4000A 5000A 6000A<br>AMP RATING<br>INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS<br>TIME IN SECONDS<br>1,000 10,000 100,000 300,000<br>1,000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
## **KRP-CL Current-limiting, Time-delay Fuses**
## **Specifications**
**Description:** Current-limiting, time-delay fuse. **Dimensions:** See page 16 for Class L dimensions. **Ratings:**
Volts — 600Vac (or less)
Amps — 225-600A IR — 200kA RMS Sym.
- Class L case size for amp ratings from 225 to 600A allows downsize fusing of large Class L fused switches for improved circuit protection.
## **Typical Applications**
- Large Distribution Switchboards
- Power Panelboards
- Machinery Disconnects
## **Catalog Numbers (Amps)**
||KRP-CL-225|KRP-CL-350|KRP-CL-500|
|---|---|---|---|
||KRP-CL-250|KRP-CL-400|KRP-CL-600|
||KRP-CL-300|KRP-CL-450||
## **Features and Benefits**
- Time-delay of four seconds at five times rating allows closer sizing inductive loads coupled with an equivalent Class L current limitation.
## **Recommended Fuse Holders & Blocks For Class L Fuses**
- See page 19
## **Data Sheet: 1016**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**39**
**Low Voltage, Branch Circuit Rated Fuses**
## **Limitron[™] Fuses**
## **KTU Class L**
## **Specifications**
**Description:** Fast-acting, bolt-mount fuse.
**Dimensions:** See page 22 for Class L dimensions. **Ratings:**
Volts — 600Vac (or less) Amps — 601-6000A
IR — 200kA RMS Sym.
**Agency Information:** CE, Std. 248-10, Class L, UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-02, File 53787.
## **Features and Benefits**
- 200kA interrupting rating provides high ratings at all circuit locations.
- Economical solutions for high-fault circuits.
- Quality construction using high-grade materials provides lower watts loss and operating temperatures with superior arc quenching during current-limiting action.
## **KLU Class L**
## **Specifications**
**Description:** Time-delay, bolt-mount fuse - 5 seconds (minimum) at 500% rated amps. See KRP-CL for amp ratings below 601A.
**Dimensions:** See page 22 for Class L dimensions.
## **Ratings:**
Volts — 600Vac (or less) Amps — 601-4000A IR — 200kA RMS Sym.
**Agency Information:** CE, Std. 248-10, Class L, UL Listed, Guide JDDZ, File E4273, CSA Certified, CSA Class 1422-02, File 53787.
## **Features and Benefits**
- 200kA interrupting rating provides high ratings at all circuit locations.
- Economical solutions for high fault circuits.
## **Typical Applications**
## **Typical Applications**
- Large Distribution Switchboards
- Power Panelboards
## **Catalog Number (Amps)**
|KTU-601|KTU-1000|KTU-2001|
|---|---|---|
|KTU-650|KTU-1100|KTU-2400|
|KTU-700|KTU-1200|KTU-2500|
|KTU-750|KTU-1400|KTU-3000|
|KTU-800|KTU-1500|KTU-3500|
|KTU-801|KTU-1600|KTU-4000|
|KTU-850|KTU-1800|KTU-5000|
|KTU-900|KTU-2000|KTU-6000|
For superior electrical protection, Cooper Bussmann recommends upgrading KTU fuse applications to Low-Peak KRP-C fuses See page 38.
## **Recommended Fuse Holders & Blocks For Class L Fuses**
- See page 19
- Large Distribution Switchboards
- Power Panelboards
- Large Machinery Disconnects
## **Catalog Numbers (Amps)**
|KLU-601|KLU-1200|KLU-2500|
|---|---|---|
|KLU-650|KLU-1500|KLU-3000|
|KLU-700|KLU-1600|KLU-4000|
|KLU-800|KLU-1800||
|KLU-1000|KLU-2000||
For superior electrical protection, Cooper Bussmann recommends upgrading KLU fuse applications to Low-Peak KRP-C fuses See page 38.
## **Recommended Fuse Holders & Blocks For Class L Fuses**
- See page 19
**Data Sheet: 1010**
**Data Sheet: 1013**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**40**
**Low Voltage, Branch Circuit Rated Fuses**
## **Low-Peak[™] Dual-element, Time-delay Fuses**
## **LPN-RK_SP (250V) Class RK1**
## **LPS-RK_SP (600V) Class RK1**
**==> picture [68 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
Available With<br>Indication<br>**----- End of picture text -----**<br>
**Specifications Description:** Current-limiting, dual-element, time-delay fuse; 10 seconds (minimum) at 500% rated amps (8 seconds for 0-30A sizes). Now available with optional indication on select ratings (see Catalog Numbers table).
**Dimensions:** See page 15 for Class RK1 dimensions. **Ratings:**
## Volts **LPN-RK:**
- 250Vac (or less)
- 125Vdc (0-60A)
- 250Vdc (70-600A)
## **LPS-RK:**
- 600Vac (or less)
- 300Vdc
Amps —[1] ⁄10-600A
- IR — 300kA RMS Sym.
## **Typical Applications**
- Large Distribution Switchboards
- Power Panelboards
- Motor Control Centers
- Machinery Disconnect Switches
## **LPN Catalog Numbers (Amps)**
|LPN-RK-1⁄10SP<br>LPN-RK-15⁄100SP<br>LPN-RK-2⁄10SP<br>LPN-RK-3⁄10SP<br>LPN-RK-4⁄10SP<br>LPN-RK-1⁄2SP<br>LPN-RK-6⁄10SP|LPN-RK-3-1⁄2SP<br>LPN-RK-4SP<br>LPN-RK-4-1⁄2SP<br>LPN-RK-5SP<br>LPN-RK-5-6⁄10SP<br>LPN-RK-6SP<br>LPN-RK-6-1⁄4SP|LPN-RK-60SP**<br>LPN-RK-70SP**<br>LPN-RK-80SP**<br>LPN-RK-90SP**<br>LPN-RK-100SP**<br>LPN-RK-110SP**<br>LPN-RK-125SP**|
|---|---|---|
|LPN-RK-8⁄10SP|LPN-RK-8SP|LPN-RK-150SP**|
|LPN-RK-1SP|LPN-RK-9SP|LPN-RK-175SP**|
|LPN-RK-1-1⁄8SP<br>LPN-RK-1-1⁄4SP<br>LPN-RK-1-4⁄10SP<br>LPN-RK-1-6⁄10SP|LPN-RK-10SP<br>LPN-RK-12SP<br>LPN-RK-15SP<br>LPN-RK-17-1⁄2SP|LPN-RK-200SP**<br>LPN-RK-225SP**<br>LPN-RK-250SP**<br>LPN-RK-300SP**|
|LPN-RK-1-8⁄10SP|LPN-RK-20SP|LPN-RK-350SP**|
|LPN-RK-2SP|LPN-RK-25SP|LPN-RK-400SP**|
|LPN-RK-2-1⁄4SP|LPN-RK-30SP|LPN-RK-450SP**|
|LPN-RK-2-1⁄2SP|LPN-RK-35SP**|LPN-RK-500SP**|
|LPN-RK-2-8⁄10SP|LPN-RK-40SP**|LPN-RK-600SP**|
|LPN-RK-3SP|LPN-RK-45SP**||
|LPN-RK-3-2⁄10SP|LPN-RK-50SP**||
*Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses.
- **Available with optional indication. To order, place “I” at end of Catalog Number. Example: LPN-RK-35SPI.
- 0-60A fuses available with Nickel plate option. (Ex: LPS-RK30SPNP) 70-600A fuses available with Tin plate option. Example: LPS-RK-100SP-TP.
- 100kA DC
**Agency Information:** CE, UL Listed – Special Purpose*, Guide JFHR, File E56412, CSA Certified (200k AIR), Class RK1 per CSA C22.2, No. 248.12, Class 1422-02, File 53787.
## **Features and Benefits**
- Separate overload and short-circuit elements provide time delay for close sizing of high inrush loads linked with RK1 current-limitation and selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents widespread blackouts.
- Inventory consolidation of Class RK1, RK5 and H fuses for reduced SKU investment and minimizing potential for misapplying fuse.
- 300kA RMS symmetrical interrupting rating provides adequate ratings without obsolescence for all electrical systems, big or small.
- Insulated end caps reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing.
## **- LPS Catalog Numbers (Amps)**
|LPS-RK-1⁄10SP|LPS-RK-2-1⁄4SP|LPS-RK-10SP**|LPS-RK-100SP**|
|---|---|---|---|
|LPS-RK-2⁄10SP|LPS-RK-2-1⁄2SP|LPS-RK-12SP**|LPS-RK-110SP**|
|LPS-RK-3⁄10SP|LPS-RK-2-8⁄10SP|LPS-RK-15SP**|LPS-RK-125SP**|
|LPS-RK-4⁄10SP|LPS-RK-3SP|LPS-RK-17-1⁄2SP**|LPS-RK-150SP**|
|LPS-RK-1⁄2SP|LPS-RK-3-2⁄10SP|LPS-RK-20SP**|LPS-RK-175SP**|
|LPS-RK-6⁄10SP|LPS-RK-3-1⁄2SP|LPS-RK-25SP**|LPS-RK-200SP**|
|LPS-RK-8⁄10SP|LPS-RK-4SP|LPS-RK-30SP**|LPS-RK-225SP**|
|LPS-RK-1SP|LPS-RK-4-1⁄2SP|LPS-RK-35SP**|LPS-RK-250SP**|
|LPS-RK-1-1⁄8SP|LPS-RK-5SP|LPS-RK-40SP**|LPS-RK-300SP**|
|LPS-RK-1-1⁄4SP|LPS-RK-5-6⁄10SP|LPS-RK-45SP**|LPS-RK-350SP**|
|LPS-RK-1-4⁄10SP|LPS-RK-6SP**|LPS-RK-50SP**|LPS-RK-400SP**|
|LPS-RK-1-1⁄2SP|LPS-RK-6-1⁄4SP**|LPS-RK-60SP**|LPS-RK-450SP**|
|LPS-RK-1-6⁄10SP|LPS-RK-7SP**|LPS-RK-70SP**|LPS-RK-500SP**|
|LPS-RK-1-8⁄10SP|LPS-RK-8SP**|LPS-RK-80SP**|LPS-RK-600SP**|
|LPS-RK-2SP|LPS-RK-9SP**|LPS-RK-90SP**||
*Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses.
- **Available with optional replace fuse indication. To order, place “I” at end of Catalog Number. Example: LPS-RK-15SPI.
**Data Sheets: LPN-RK — 1003 (0-60) and 1004 (70-600) LPN-RK with indication — 1066 (70-600) LPS-RK — 1001 (0-60) and 1002 (70-600) LPS-RK with indication — 1061 (0-60) and 1064 (70-600)**
## **Recommended Fuse Holders & Blocks For Class RK1 Fuses**
• See page 19
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**41**
**Low Voltage, Branch Circuit Rated Fuses**
## **Low-Peak[™] Dual-element, Time-delay Fuses**
**Time-Current Characteristic Curves—Average Melt**
**==> picture [172 x 578] intentionally omitted <==**
**----- Start of picture text -----**<br>
LPN-RK AMP RATING<br>15 20 30 60 100 200 400 600<br>300<br>AUN TIK A TWIT EE<br>100<br>EAANIAAEA AINSI<br>=EAA<br>SOYA A<br>10<br>AE<br>ee \ |<br>1 ME<br>RRSAAAee AYA|<br>.1 AWE<br>SSSA<br>Re ae<br>= SAA<br>OTT AYENN<br>.01<br>CURRENT IN AMPS<br>LPS-RK<br>AMP RATING<br>20 30 60 100 200 400 600<br>300 [NENTNT RUATY TET TTT<br>100<br>10<br>“THIN AAA AAT<br>1 TVA<br>meee<br>PETE TAT<br>.1<br>PTT TATATEN TT TAT<br>.01 CPTI CANIN ACIN<br>CURRENT IN AMPS<br>TIME IN SECONDS<br>20 100 1,000<br>10,000<br>TIME IN SECONDS<br>20 100 1,000 10,000<br>**----- End of picture text -----**<br>
**Data Sheets: LPN-RK — 1003 (0-60) and 1004 (70-600) Data Sheets: LPS-RK — 1001 (0-60) and 1002 (70-600)**
**==> picture [204 x 283] intentionally omitted <==**
**----- Start of picture text -----**<br>
LPN-RK<br>AMP RATING<br>300 100 WAV\\ \\ | \\A\\ \\<br>LQ)<br>MQQQQ<br>10<br>WANA<br>ieeeeiiih Wn a (a Gan Vn \ ee \\<br>1 UA<br>VAYALY A\<br>.1 VAALAYA AY\<br>See aiiieees te ei Sees th See a l<br>\ \ \\<br>.01 FTIVAALTTNTT,AUT AN<br>RMS SYMMETRICAL CURRENT IN AMPS<br>/110 /15100 /210 /310 /4/110 2 /610 /810 1 /114 /1610 2 /212 /3210 4 5 /614 8 10 12<br>TIME IN SECONDS<br>.1 1 10 100 1,000<br>**----- End of picture text -----**<br>
**==> picture [197 x 259] intentionally omitted <==**
**----- Start of picture text -----**<br>
LPS-RK<br>AMP RATING<br>S\N<br>AAA<br>\ \<br>— VV VV VVYAN<br>o x CITI TTI \ SNTINN\ \ AIT\\\<br>CURRENT IN AMPS<br>/210 /12 /610 /114 2 /3210 /614 10<br>/110 /15100 /310 /410 /810 1 /1610 /212 4 5 8 12<br>TIME IN SECONDS<br>**----- End of picture text -----**<br>
**Recommended Fuse Holders & Blocks For Class RK1 Fuses** • See page 19
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**42**
**Low Voltage, Branch Circuit Rated Fuses**
## **Low-Peak[™] Dual-element, Time-delay Fuses**
## **Current Limitation Curves—LPN-RK**
**==> picture [252 x 247] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>400,000<br>100,000<br>600<br>400<br>200<br>100<br>60<br>10,000<br>30<br>A<br>1,000<br>RMS SYMMETRICAL CURRENTS IN AMPS<br>A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)<br>AMP RATING<br>INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS<br>1,000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
## **Current Limitation Curves—LPS-RK**
**==> picture [209 x 192] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS<br>**----- End of picture text -----**<br>
**Recommended Fuse Holders & Blocks For Class RK1 Fuses** • See page 19
**Data Sheets: LPN-RK — 1003 (0-60) and 1004 (70-600) Data Sheets: LPS-RK — 1001 (0-60) and 1002 (70-600)**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**43**
**Low Voltage, Branch Circuit Rated Fuses**
## **Limitron[™] Fast-acting Fuses**
## **KTN-R (250V) Class RK1**
## **Time-Current Characteristic Curves—Average Melt**
## **Specifications**
**Description:** Fast-acting, current-limiting fuse.
**Dimensions:** See page 21 for Class RK1 dimensions.
**Ratings:** Volts — 250Vac (or less) Amps — 1-600A IR — 200kA RMS Sym.
**Agency Information:** CE, Std. 248-12, Class RK1, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787.
## **Features and Benefits**
- Current limitation for non-inductive circuits provides Class RK1 current-limiting response to maximum ground fault and short-circuit conditions.
- 200kA interrupting rating provides high ratings at all circuit locations.
- Economical solutions for high-fault circuits.
## **Typical Applications**
- Panelboards
## **Catalog Numbers (Amps)**
|KTN-R-1<br>KTN-R-30<br>KTN-R-125<br>~~a~~|
|---|
|KTN-R-2<br>KTN-R-35<br>KTN-R-150<br>~~—~~|
|KTN-R-3<br>KTN-R-40<br>KTN-R-175<br>KTN-R-4<br>KTN-R-45<br>KTN-R-200<br>KTN-R-5<br>KTN-R-50<br>KTN-R-225<br>~~a~~<br>~~ee~~|
|KTN-R-6<br>KTN-R-60<br>KTN-R-250|
|KTN-R-8<br>KTN-R-70<br>KTN-R-300|
|KTN-R-10<br>KTN-R-75<br>KTN-R-350<br>KTN-R-12<br>KTN-R-80<br>KTN-R-400<br>KTN-R-15<br>KTN-R-90<br>KTN-R-450<br>~~ss~~<br>~~TTT TTTTTTTNW—OCYCT@LM®NWOL~~<br>~~ee~~<br>~~a~~|
|KTN-R-20<br>KTN-R-100<br>KTN-R-500<br>KTN-R-25<br>KTN-R-110<br>KTN-R-600<br>~~Tf~~<br>~~TTT >a~~<br>~~a~~|
## **Current Limitation Curves**
For superior electrical protection, Bussmann recommends upgrading KTN-R fuse applications to Low-Peak LPN-RK fuses See page 41.
**Recommended Fuse Holders & Blocks For Class RK1 Fuses**
• See page 19
**Data Sheet: 1043**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**44**
**Low Voltage, Branch Circuit Rated Fuses** SE
## **Limitron[™] Fast-acting Fuses**
## **KTS-R (600V) Class RK1**
## **Specifications**
**Description:** Fast-acting, current-limiting fuse.
**Dimensions:** See page 21 for Class RK1 dimensions.
## **Ratings:**
Volts — 600Vac (or less)
Amps — 1-600A
IR — 200kA RMS Sym.
**Agency Information:** CE, Std. 248-12, Class RK1, UL Listed, Guide JDDZ, File E54273, CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787.
## **Features and Benefits**
- Current limitation for non-inductive circuits provides Class RK1 current-limiting response to maximum ground fault and short-circuit conditions.
- 200kA interrupting rating provides high ratings at all circuit locations.
- Economical solutions for high-fault circuits.
## **Typical Applications**
- Panelboards
|**Catalog Numbers(Amps)**<br>KTS-R-1<br>KTS-R-30<br>KTS-R-125<br>KTS-R-2<br>KTS-R-35<br>KTS-R-150<br>KTS-R-3<br>KTS-R-40<br>KTS-R-175<br>KTS-R-4<br>KTS-R-45<br>KTS-R-200<br>~~es~~|**Catalog Numbers(Amps)**<br>KTS-R-1<br>KTS-R-30<br>KTS-R-125<br>KTS-R-2<br>KTS-R-35<br>KTS-R-150<br>KTS-R-3<br>KTS-R-40<br>KTS-R-175<br>KTS-R-4<br>KTS-R-45<br>KTS-R-200<br>~~es~~|**Catalog Numbers(Amps)**<br>KTS-R-1<br>KTS-R-30<br>KTS-R-125<br>KTS-R-2<br>KTS-R-35<br>KTS-R-150<br>KTS-R-3<br>KTS-R-40<br>KTS-R-175<br>KTS-R-4<br>KTS-R-45<br>KTS-R-200<br>~~es~~|
|---|---|---|
|KTS-R-5<br>KTS-R-6<br>KTS-R-8<br>KTS-R-10|KTS-R-50<br>KTS-R-60<br>KTS-R-70<br>KTS-R-75|KTS-R-225<br>KTS-R-250<br>KTS-R-300<br>KTS-R-350|
|KTS-R-12|KTS-R-80|KTS-R-400|
|KTS-R-15|KTS-R-90|KTS-R-450|
|KTS-R-20|KTS-R-100|KTS-R-500|
|KTS-R-25|KTS-R-110|KTS-R-600|
For superior electrical protection, Bussmann recommends upgrading KTN-R fuse applications to Low-Peak LPN-RK fuses See page 41.
**Recommended Fuse Holders & Blocks For Class RK1 Fuses**
• See page 19
## **Time-Current Characteristic Curves–Average Melt**
**==> picture [192 x 615] intentionally omitted <==**
**----- Start of picture text -----**<br>
AMPERE<br>RATING<br>300 VV y yyy<br>100<br>YY yy<br>ACA AA<br>yy yyy<br>10<br>VW VV<br>FA<br>VV VA<br>1<br>ICENTUILAT<br>.1<br>WME ALATA LAIN<br>ee NE VS<br>oenh oe oe VO<br>N\A<br>.01<br>RMS SYMMETRICAL CURRENT IN AMPERES<br>Current-Limitation Curves<br>400,000 eat eR B<br>100,000<br>IE| 600<br>400<br>200<br>Career 100<br>10,000 60<br>30<br>A<br>1,000 cil<br>RMS SYMMETRICAL CURRENTS IN AMPERES<br>A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 x SYMM RMS AMPS)<br>30A 60A 100A 200A 400A 600A<br>TIME IN SECONDS<br>40 100 1,000 10,000<br>AMPERE RATING<br>INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS<br>1,000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
## **Current-Limitation Curves**
**Data Sheet: 1044**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**45**
**Low Voltage, Branch Circuit Rated Fuses**
## **Fusetron[™] Energy Efficient, Dual-element, Time-delay Fuses**
## **FRN-R (250V) Class RK5**
## **Specifications**
**Description:** Dual-element, time-delay fuse – 10 seconds (minimum) at 500% rated amps (8 seconds for 0-30A sizes). Available with indication on select ratings (see Catalog Numbers table).
**Dimensions:** See page 15 for Class RK5 dimensions.
## **Ratings:**
Volts — 250Vac (or less)
— 125Vdc ([1] ⁄10-60A, 110-200A)
— 250Vdc (225-600A)
Amps —[1] ⁄10-600A _**AvailableWith**_ EAYFUSEelement a IR — 200kA RMS Sym. _**Indication**_ T LIMITINGN agOo= RK5 i — 20kA DC — oO Ns_
**Agency Information:** CE, Std. 248-12, Class RK5, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-01, File 53787.
## **Features and Benefits**
- Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA.
- 2:1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses.
- Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing.
## **Typical Applications**
- Power Panelboards
|• Motor Control Centers|• Motor Control Centers<br>**Catalog Numbers(Amps)**<br>FRN-R-1⁄10<br>FRN-R-2<br>FRN-R-10*<br>FRN-R-100<br>FRN-R-1⁄8<br>FRN-R-2-1⁄4<br>FRN-R-12*<br>FRN-R-110<br>FRN-R-15⁄100<br>FRN-R-2-1⁄2<br>FRN-R-15*<br>FRN-R-125<br>FRN-R-2⁄10<br>FRN-R-2-8⁄10<br>FRN-R-17-1⁄2*<br>FRN-R-150<br>• Combination Starters<br>• Machinery Disconnects<br>~~—_J_~~<br>~~a~~<br>~~—————E~~|• Motor Control Centers<br>**Catalog Numbers(Amps)**<br>FRN-R-1⁄10<br>FRN-R-2<br>FRN-R-10*<br>FRN-R-100<br>FRN-R-1⁄8<br>FRN-R-2-1⁄4<br>FRN-R-12*<br>FRN-R-110<br>FRN-R-15⁄100<br>FRN-R-2-1⁄2<br>FRN-R-15*<br>FRN-R-125<br>FRN-R-2⁄10<br>FRN-R-2-8⁄10<br>FRN-R-17-1⁄2*<br>FRN-R-150<br>• Combination Starters<br>• Machinery Disconnects<br>~~—_J_~~<br>~~a~~<br>~~—————E~~|• Motor Control Centers<br>**Catalog Numbers(Amps)**<br>FRN-R-1⁄10<br>FRN-R-2<br>FRN-R-10*<br>FRN-R-100<br>FRN-R-1⁄8<br>FRN-R-2-1⁄4<br>FRN-R-12*<br>FRN-R-110<br>FRN-R-15⁄100<br>FRN-R-2-1⁄2<br>FRN-R-15*<br>FRN-R-125<br>FRN-R-2⁄10<br>FRN-R-2-8⁄10<br>FRN-R-17-1⁄2*<br>FRN-R-150<br>• Combination Starters<br>• Machinery Disconnects<br>~~—_J_~~<br>~~a~~<br>~~—————E~~|
|---|---|---|---|
||FRN-R-1⁄4<br>FRN-R-3|FRN-R-20*|FRN-R-175|
||FRN-R-3⁄10<br>FRN-R-3-2⁄10<br>FRN-R-4⁄10<br>FRN-R-3-1⁄2<br>FRN-R-1⁄2<br>FRN-R-4|FRN-R-25*<br>FRN-R-30*<br>FRN-R-35*|FRN-R-200<br>FRN-R-225<br>FRN-R-250|
||FRN-R-6⁄10<br>FRN-R-4-1⁄2|FRN-R-40*|FRN-R-300|
||FRN-R-8⁄10<br>FRN-R-5|FRN-R-45*|FRN-R-350|
||FRN-R-1<br>FRN-R-5-6⁄10|FRN-R-50*|FRN-R-400|
||FRN-R-1-1⁄8<br>FRN-R-6|FRN-R-60*|FRN-R-450|
||FRN-R-1-1⁄4<br>FRN-R-6-1⁄4|FRN-R-70|FRN-R-500|
||FRN-R-1-4⁄10<br>FRN-R-7|FRN-R-75|FRN-R-600|
||FRN-R-1-1⁄2<br>FRN-R-7-1⁄2<br>FRN-R-1-6⁄10<br>FRN-R-8*|FRN-R-80<br>FRN-R-85||
||FRN-R-1-8⁄10<br>FRN-R-9*|FRN-R-90||
*Available with indication. To order, place “ID” at the end of the catalog number. Example: FRN-R-30ID
## **Time-Current Characteristic Curves—Average Melt**
**==> picture [191 x 489] intentionally omitted <==**
**----- Start of picture text -----**<br>
peeeofea tT a T eatTPT tacitTry T artaieestiee em r ererinartieee 4 ne se ec<br>sooff VATE aT VP TE EE e co<br>Stee et tS eel coe et eS S e S<br>sol}votNA FETTAIT TTT TNT TMT TTeee so<br>WATER AIAN A er<br>ee UATATE N<br>BESAACEREE4 WW YNEEE AREERkNEERIE R E<br>oe A ee<br>sol} ARTA ATT AREE e<br>“ERAE N<br>vot“SEACON EERIE REEooEE N,E<br>LT TET<br>aJUTtBLE E EEN EEEE EEAENTINTTTNEE E -AFACETED EEA E FF E,<br>ca E s<br>sf a TTTeeA PA TE AE VE e<br>eeB ee es oeuee ee COE OE , Oe O c<br>2Y t<br>v i TTT TTT TMT TTT es<br>PLETE TTT ATE PTT<br>LEC T<br>SEBSaeg a a a BEEF EEE| HEEEERI eE<br>pa<br>a<br>i eeea eee|tee teen eee ett ete Ee<br>NaA ee eeeAee en en<br>CETTNATIT ECE E TT T<br>a<br>6SEER PR E<br>atee| TTT rT riiiy TINT PNP TY NT RTT aeeNT TT eT<br>e e<br>I LTTE APPT TETYEATETTTPNTT<br>LL ETTATTATYEATETAT S EN E T ,<br>Current Limitation Curves<br>400,000 B<br>J<br>100,000 ee FRN-R il<br>600<br>Saar 400<br>of On 200<br>100<br>60<br>10,000 feee Zafer 30<br>erragea heZ cal<br>A<br>1,000<br>RMS Symmetrical Currents In Amps<br>A–B = Asymmetrical Available Peak (2.3 x Sym RMS Amps)<br>8 10 15 30 60 100 200 400 600<br>Amp Rating<br>Instantaneous Peak Let-Through Current Amps<br>1,000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
## **Current Limitation Curves**
For superior electrical protection, Bussmann recommends upgrading FRN-R fuse applications to Low-Peak LPN-RK fuses. See page 41.
## **Recommended Fuse Holders & Blocks For Class RK5 Fuses**
- See page 19
## **Recommended Fuse Reducers For Class R Fuses**
- See page 20
**Data Sheets: 1019 ([1] ⁄10-60) and 1020 (70-600) Data Sheet: 1169 (8-60) FRN-R with indication**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**46**
**Low Voltage, Branch Circuit Rated Fuses**
## **Fusetron[™] Energy Efficient, Dual-element, Time-delay Fuses**
## **FRS-R (600V) Class RK5**
## **Time-Current Characteristic Curves—Average Melt**
## **Specifications**
**Description:** Dual-element, time-delay fuse – 10 seconds (minimum) at 500% rated amps. Now available with optional indication on select ratings (see Catalog Numbers table).
**Dimensions:** See page 15 for Class RK5 dimensions. **Ratings:**
Volts — 600Vac (or less) Amps —[1] ⁄10-30A
IR — 200kA RMS Sym. — 20kA @300Vdc
Amps — 35-60A IR — 200kA RMS Sym.. — 20kA @250Vdc
_**Available**_ Amps — 65-600A _**With**_ IR — 200kA RMS Sym. _**Indication**_ — 20kA @250Vdc
**Agency Information:** CE, Std. 248-12,
Class RK5, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787.
## **Features and Benefits**
- 2:1 selective coordination ratio (within RK5 fuse family) prevents electrical shutdowns from extending beyond the failed circuit.
- Insulated end caps for 65-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing.
## **Typical Applications**
- Power Panelboards
• Motor Control Centers
|**Catalog Numbers(Amps)**<br>FRS-R-1⁄10<br>FRS-R-2<br>FRS-R-10*<br>FRS-R-100<br>FRS-R-1⁄8<br>FRS-R-2-1⁄4<br>FRS-R-12*<br>FRS-R-110<br>FRS-R-15⁄100<br>FRS-R-2-1⁄2<br>FRS-R-15*<br>FRS-R-125<br>FRS-R-2⁄10<br>FRS-R-2-8⁄10<br>FRS-R-17-1⁄2*<br>FRS-R-150<br>FRS-R-1⁄4<br>FRS-R-3<br>FRS-R-20*<br>FRS-R-175<br>FRS-R-3⁄10<br>FRS-R-3-2⁄10<br>FRS-R-25*<br>FRS-R-200<br>FRS-R-4⁄10<br>FRS-R-3-1⁄2<br>FRS-R-30*<br>FRS-R-225<br>FRS-R-1⁄2<br>FRS-R-4<br>FRS-R-35*<br>FRS-R-250<br>FRS-R-6⁄10<br>FRS-R-4-1⁄2<br>FRS-R-40*<br>FRS-R-300<br>FRS-R-8⁄10<br>FRS-R-5<br>FRS-R-45*<br>FRS-R-350<br>FRS-R-1<br>FRS-R-5-6⁄10<br>FRS-R-50*<br>FRS-R-400<br>FRS-R-1-1⁄8<br>FRS-R-6*<br>FRS-R-60*<br>FRS-R-450<br>FRS-R-1-1⁄4<br>FRS-R-6-1⁄4*<br>FRS-R-65<br>FRS-R-500<br>• Combination Starters<br>~~• Machinery Disconnects~~<br>~~TT~~<br>~~332377 0000505~~<br>~~HH~~<br>~~oo~~<br>~~**e**e~~<br>~~e~~<br>~~OT~~<br>~~TTT~~<br>~~iS~~|
|---|
|FRS-R-1-4⁄10<br>FRS-R-7*<br>FRS-R-70<br>FRS-R-600|
|FRS-R-1-1⁄2<br>FRS-R-7-1⁄2*<br>FRS-R-75<br>FRS-R-1-6⁄10<br>FRS-R-8*<br>FRS-R-80<br>FRS-R-18⁄10<br>FRS-R-9*<br>FRS-R-90|
*Available with indication. To order, place “ID” at the end of the catalog number. Example: FRS-R-7ID.
For superior electrical protection, Bussmann recommends upgrading FRS-R fuse applications to Low-Peak LPS-RK fuses. See page 41.
**Data Sheet: 1017 ([1] ⁄10-60), 1018 (65-600) Data Sheet: 1070 (6-60) FRS-R with Indication**
## **Current Limitation Curves**
**==> picture [223 x 242] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>400,000 eeee) FRS-R (600V) ae<br>100,000 eeeS SCNO|<br>a CSCS OO 7 SO 600A<br>aAa OOa OO«Oe2 400A<br>a ee<br>200A<br>100A<br>ee 2 60A<br>10,000 |eeP||yWe e erre 15A30A<br>Of eee eeeeeee<br>Ofns e Te e eee eeeee<br>| Ae ee ee<br>A VAp ae<br>1,000<br>RMS Symmetrical Currents In Amps<br>A–B = Asymmetrical Available Peak (2.3 x Sym RMS Amps)<br>Amp Rating<br>Instantaneous Peak Let-Through Current Amps<br>1,000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
**Recommended Fuse Holders & Blocks For Class RK5 Fuses**
- See page 19
**Recommended Fuse Reducers For Class R Fuses**
- See page 20
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**47**
**Low Voltage, Branch Circuit Rated Fuses**
## **T-Tron[™] Fast-acting Fuses**
## **JJN Class T**
## **Specifications**
**Description:** Fast-acting, current-limiting fuse.
**==> picture [234 x 42] intentionally omitted <==**
**----- Start of picture text -----**<br>
Time-Current Characteristic Curves—Average Melt<br>Seeretee oe<br>**----- End of picture text -----**<br>
**Dimensions:** See page 16 for Class T dimensions.
## **Ratings:**
Volts — 300Vac (or less) — 160Vdc (15-600A) — 170Vdc (601-1200A)
Amps — 1-1200A IR — 200kA RMS Sym. — 20kA DC @ 160Vdc
— 100kA DC @ 170Vdc
**Agency Information:** CE, Std. 248-15, Class T, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787.
## **Features and Benefits**
- Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer.
- Current limitation for non-inductive circuits provides Class T current-limiting response to maximum ground fault and short-circuit conditions.
- 200kA interrupting rating provides high ratings at all circuit locations.
- Small footprint allows more efficient use of available space.
## **Typical Applications**
- Large Apartment Complexes
- Multi-Family Meter Stacks
- VFD Line Protection
## **Catalog Numbers (Amps)**
|**Catalog Numbers (Amps)g Numbers (Amps) Numbers (Amps)(Amps)Amps))**||||
|---|---|---|---|
|JJN-1<br>JJN-15<br>JJN-40<br>JJN-80|JJN-150|JJN-300|JJN-600|
|JJN-2<br>JJN-20<br>JJN-45<br>JJN-90<br>JJN-175<br>JJN-350<br>JJN-700<br>JJN-3<br>JJN-25<br>JJN-50<br>JJN-100<br>JJN-200<br>JJN-400<br>JJN-800<br>JJN-6<br>JJN-30<br>JJN-60<br>JJN-110<br>JJN-225<br>JJN-450<br>JJN-1000<br>~~SO~~<br>_ _~~__— oo~~<br>~~eee~~||||
|JJN-10<br>JJN-35<br>JJN-70<br>JJN-125|JJN-250|JJN-500|JJN-1200|
## **Current Limitation Curves**
**==> picture [13 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
JJN<br>**----- End of picture text -----**<br>
## **Recommended Fuse Holders & Blocks For Class T Fuses**
• See page 19
**Data Sheet: 1025**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**48**
**Low Voltage, Branch Circuit Rated Fuses**
## **T-Tron[™] Fast-acting Fuses**
## **JJS Class T**
## **Specifications**
**Description:** Very fast-acting, current-limiting fuse.
**Dimensions:** See page 16 for Class T dimensions.
**==> picture [234 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
Time-Current Characteristic Curves—Average Melt <= =< it<br>JJS<br>**----- End of picture text -----**<br>
## **Ratings:**
Volts — 600Vac (or less) Amps — 1-800A
IR — 200kA RMS Sym.
**Agency Information:** CE, Std. 248-15, Class T, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787.
## **Features and Benefits**
- Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer.
- Current limitation for non-inductive circuits provides Class T current-limiting response to maximum ground fault and short-circuit conditions.
- 200kA interrupting rating provides high ratings at all circuit locations.
- Small footprint allows more efficient use of available space.
## **Typical Applications**
• Large Apartment Complexes
- Multi-Family Meter Stacks
- VFD Line Protection
**Catalog Numbers (Amps)**
**==> picture [251 x 67] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|JJS-1JJS-2|a|JJS-15JJS-20|JJS-40JJS-45|JJS-80JJS-90|JJS-150JJS-175|JJS-300JJS-350|JJS-600JJS-800|
|JJS-3|JJS-25|JJS-50|JJS-100|JJS-200|JJS-400|
|JJS-6|—__—————_|JJS-30|JJS-60|JJS-110|JJS-225|JJS-450|
|JJS-10|TTT|JJS-35|JJS-70|JJS-125|JJS-250|JJS-500|—_|
|zCOS|
**----- End of picture text -----**<br>
## **Current Limitation Curves**
**==> picture [13 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
JJS<br>**----- End of picture text -----**<br>
## **Recommended Fuse Holders & Blocks For Class T Fuses**
• See page 19
**Data Sheet: 1029**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**49**
**Low Voltage, Branch Circuit Rated Fuses**
## **Plug Fuses**
## **W Series**
## **Specifications**
**Description:** Fast-acting plug fuse.
**Dimensions:** Edison base plug. **Construction:** Brass threads with plastic body.
## **Ratings:**
Volts — 125Vac Amps —[1] ⁄2-12A
IR — 10kA RMS Sym.
**Agency Information:** CE, Std. 248-11, UL Listed, Guide JEFV, File E12112.
## **SL and TL Series**
## **Specifications**
**Description:** Time-delay, loaded link plug fuse.
## **Dimensions:**
SL — Rejection base TL — Edison base
## **Construction:**
SL — Plastic base with rejection threads
TL — Brass threads with plastic body
## **Ratings:**
Volts — 125Vac
Amps — 15-30A
## **Features and Benefits**
- Dependable, fast-acting circuit protection with 10kA interrupting rating for added safety when applied to existing plug fuse systems and 125-volt single-phase control circuits.
## **Typical Applications**
- Replacement only in existing systems.
- For general purpose circuit protection.
- Use for lighting and other non-motor circuits.
## **Catalog Numbers* (Amps)**
|W-1⁄2<br>W-1<br>W-1|W-18⁄10|W-2<br>W-3<br>W-4|W-21⁄2|W-6<br>W-6<br>W-7|W-61⁄2|W-10<br>W-12<br>W-DUMMY**|
|---|---|---|---|---|---|---|
|W-2||W-5||W-8|||
*W-15, W-20, W-25, and W-30 plug fuses obsoleted. Suggest replacing with either T-(Amp) or TL-(Amp) plug fuses.
- ** Non-conductive dummy base. Not a fuse.
IR — 10kA RMS Sym.
**Agency Information:** CE, Std. 248-11, UL Listed, Guide JEFV, File E12112.
## **Features and Benefits**
- Time-delay loaded link TL Series Edison base plug fuses pass motor overload starting currents without opening and allow closer sizing to motor load for added protection.
- Time-delay loaded link SL Series fuses provide a rejection feature (when used alone or with Fustat adapters to retrofit Edison base holders) to help prevent overfusing.
## **Typical Applications**
- Small motor and inductive load circuits with high in-rush current levels.
- Used with box cover units to provide equipment protection.
- Applications benefiting from fuse rejection (SL Series only).
## **SL Catalog Numbers (Amps)**
SL-15 SL-20 SL-25 SL-30
## **TL Catalog Numbers (Amps)**
TL-15 TL-20 TL-25 TL-30
## **Data Sheet: 1036**
**Recommended Fuse Holders For W Series Plug Fuses**
• See page 20
## **Data Sheets: 1033 (SL) & 1035 (TL)**
**Recommended Fuse Holders For SL & TL Series Plug Fuses**
- See page 20
- See page 52 for Fustat adapters for use with SL Series
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**50**
**Low Voltage, Branch Circuit Rated Fuses**
## **Plug Fuses**
## **S and T Series**
## **Specifications**
**Description:** Dual-element, time-delay plug fuse.
## **Dimensions:**
S — Rejection base T — Edison base
**Construction:**
S — Plastic base with rejection threads T — Brass threads with plastic body
## **Ratings:**
Volts — 125Vac
Amps — S Series:[1] ⁄4-30A — T Series:[3] ⁄10-30A
- IR — 10kA RMS Sym.
**Agency Information:** CE, Std. 248-11, Type S and T: UL Listed (0-6[1] ⁄4) Guide JFHR, File E56412 (7-30A) Guide JEFV, File E12112; CSA Certified, Class 1423-01, File 53787.
## **Features and Benefits**
- Time-delay, dual-element T Series Edison base plug fuses provide small motor overload protection when used with box cover units.
- Time-delay, dual-element S Series plug fuses provide a rejection feature (when used alone or with Fustat adapters to retrofit Edison base holders) to prevent overfusing of branch circuits.
## **Typical Applications**
## **P & TC Series**
**Specifications Description:**
P Series - Type P dual-element fuse TC Series - Type D dual-element, time-delay fuse
## **Dimensions:** Edison base
**Construction:** Brass threads with plastic body.
## **Ratings:**
Volts — 125Vac or less
Amps — 15-30A IR — 10kA
## **Agency Information:**
P Series - CSA Certified
TC Series - CSA Certified (Class 1423-01, File # 53787)
## **Features and Benefits**
P Series
- “P” Rating for Canadian applications.
- Non-time delay for non-inductive loads
- TC Series
- “D” Rating for Canadian applications
- Heavy duty TC fuses are industrial strength products, featuring dual-element construction.
- This spring loaded design provides superior short-circuit and overload protection.
- The TC fuses have more time-delay than the medium duty fuses in order to better protect industrial motors and residential circuits.
- S Series — Residential Load Centers
- T Series — Box Cover Units for small motor overload protection
- Applications benefiting from fuse rejection (S Series only)
## **S Series Catalog Numbers (Amps)**
|**S Series Catalog Numbers (Amps)**|**S Series Catalog Numbers (Amps)g Numbers (Amps) Numbers (Amps)**|**S Series Catalog Numbers (Amps)g Numbers (Amps) Numbers (Amps)**|**S Series Catalog Numbers (Amps)g Numbers (Amps) Numbers (Amps)(Amps)Amps)ps)s))**||||
|---|---|---|---|---|---|---|
|S-1⁄4|S-8⁄10|S-1-6⁄10|S-2-1⁄2|S-4|S-7|S-14|
|S-3⁄10|S-1|S-1-8⁄10|S-2-8⁄10|S-4-1⁄2|S-8|S-15|
|S-4⁄10<br>S-1⁄2|S-1-1⁄8<br>S-1-1⁄4|S-2<br>S-2-1⁄4|S-3<br>S-3-2⁄10|S-5<br>S-6|S-9<br>S-10|S-20<br>S-25|
|S-6⁄10|S-1-4⁄10|S-5-6⁄10|S-3-1⁄2|S-6-1⁄4|S-12|S-30|
|**T Series Catalo**|**T Series Catalog Numbers**|**Numbers**|**Numbers(Amps)**||||
|T-3⁄10|T-1-1⁄8|T-2-1⁄4|T-4|T-7|T-15||
|T-4⁄10|T-1-1⁄4|T-2-1⁄2|T-4-1⁄2|T-8|T-20||
|T-1⁄2|T-1-4⁄10|T-2-8⁄10|T-5|T-9|T-25||
|T-6⁄10|T-1-6⁄10|T-3|T-5-6⁄10|T-10|T-30||
|T-8⁄10|T-1-8⁄10|T-3-2⁄10|T-6|T-12|||
|T-1|T-2|T-3-1⁄2|T-6-1⁄4|T-14|||
**Data Sheet: 1032 (S) & 1034 (T) Recommended Fuse Holders For S & T Series Plug Fuses**
- See page 20
- See page 52 for Fustat adapters for use with S Series
## **Typical Applications**
- P Series — Non-inductive loads, residential load centers
- TC Series — Box Cover Units for small motor overload protection
|**P Series Catalo**|**P Series Catalog Numbers**|**Numbers(Amps)**|
|---|---|---|
|P-15|P-20|P-25<br>P-30|
|**TC Series Catalog Numbers(Amps)**|||
|TC-15|TC-20|TC-25<br>TC-30|
## **Data Sheet: 1039 (TC Series only)**
## **Recommended Fuse Holders For P & TC Series Plug Fuses**
• See page 20
- See page 52 for Fustat adapters for use with S Series
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**51**
**Low Voltage, Branch Circuit Rated Fuses**
## **Plug Fuses**
## **MB Edison Base Circuit Breakers**
## **SA Fustat Fuse Adapters**
## **Specifications**
**Description:** Adapters for using Type S and SL rejection fuses in Edison base fuse sockets.
## **Specifications**
**Description:** Edison base manual reset circuit breakers. **Dimensions:** Edison base
**Construction:** Brass threads with plastic body
## **Ratings:**
Volts — 125Vac only Amps — 15-20A
IR — 10kA RMS Sym. **Agency Information:** UL Listed, File E14942
## **Features and Benefits**
- Fit standard Edison base fuse receptacles.
- Resettable upon overload event.
## **Typical Applications***
- Replacing Edison base plug fuses in residential fuse panels.
- **Catalog Numbers* (Amps)**
MB-15 MB-20
**Agency Information:** UL Listed, File E12853; CSA Certified File #6225-01, File #47235.
## **Features and Benefits**
- Fustat adapters screw into the “Edison” thread fuse sockets of standard fuse boxes making it easy to retrofit existing fuse installations
- Available in various amp ratings to cover a wide range of rating requirements
## **Typical Applications**
- Plug fuse installations where it is desirable to restrict fuse amp ratings
## **Catalog Numbers (Amps)**
|SA-1*|SA-3-2⁄10*|SA-10*|
|---|---|---|
|SA-1-1⁄4*|SA-4*|SA-15**|
|SA-1-6⁄10*|SA-5*|SA-20**|
|SA-2*<br>SA-2-1⁄2*|SA-6-1⁄4*<br>SA-8*|SA-30**|
* Single motor circuits.
** Branch circuits.
* Not for use in box cover units or for inductive loads.
## **Fustat[®] Adapters for Small Motor Protection***
|**Adapter**|**Accepts Fuses**|
|---|---|
|SA-1|S-1 or smaller|
|SA-1-1⁄4|S-1-1⁄4 or smaller|
|SA-1-6⁄10|S-1-6⁄10 or smaller|
|SA-2|S-2 or S-1-8⁄10|
|SA-2-1⁄2|S-2-1⁄2 to S-1-8⁄10|
|SA-3-2⁄10|S-3-2⁄10 to S-1-8⁄10|
|SA-4|S-4 to S-3-1⁄2|
|SA-5|S-5 to S-3-1⁄2|
|SA-6-1⁄4|S-6-1⁄4 to S-3-1⁄2|
|SA-8|S-8 to S-7|
|SA-10|S-10 to S-7|
|SA-15|S-15 to S-7|
|SA-20|S-20|
|SA-30|S-30 to S-20|
* Both motor running and short-circuit protection.
## **Fustat[®] Adapters for Branch Circuit Protection**
|**Adapter**|**Accepts Fuses**|
|---|---|
|SA-15|S-15 to S-7|
|SA-20|S-20|
|SA-30|S-25|
|SA 30|S-30 to S-20|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**52**
## **Solar Fuse Products**
Scan this tag to get the latest product information for Solar Products.
|**Page**|
|---|
|**Fuse Holder & Block Selection Guide**<br>**54-55**|
|**Volt**<br>**Fuses**<br>**Size**|
|600Vdc . . . . . . . . .**PVM**. . . . . 13⁄32˝ x 11⁄2˝ . . . . . . . . . . . 56|
|600Vac /300Vdc . . .**PVCF**. . . . .CUBEFuse . . . . . . . . .57-58|
|600Vac/dc . . . . . . .**PVS-R**. . . .RK5. . . . . . . . . . . . . . . .59|
|1000Vdc . . . . . . . . **PV**. . . . . . .10x38mm . . . . . . . . . . . 60|
|1000/1100Vdc . . . .**PV**. . . . . . .14x51mm . . . . . . . . . . .61|
|1000Vdc . . . . . . . .**NH1**. . . . . .NH Size 1 . . . . . . . . . . . 62|
|1000Vdc . . . . . . . .**XL PV**. . . .XL Size 01, 1, 2, 3 . . .63-65|
|1300/1500Vdc . . . .**PV**. . . . . . .14x65mm . . . . . . . . . . . 66|
|1200/1500Vdc . . . .**XL PV**. . . .XL Size 01, 1, 2, 3 . . .67-69|
## **RED indicates NEW information**
**53**
**Solar Fuse Products**
## **Holders & Blocks For Branch Circuit Rated Fuses**
|**600 Volts**<br>**Fuses**|**Volts**|**Page**|
|---|---|---|
|Midget<br>PVM|600V|56|
|CF<br>CFPV<br>RK5<br>PVS-R|600V<br>600V|57<br>59|
|**Holders**|||
|• TCFH Series CUBEFuse holder||32|
|• CHM Series DIN-Rail mount holders<br>• HEB Series in-line holders||274<br>310|
|**Blocks**|||
|• Modular Knifeblade Fuse Blocks 250/600V, panel mount . . 289||Modular Knifeblade Fuse Blocks 250/600V, panel mount . . 289|
|• R600 Series RK5 open fuse blocks||296|
|• BM Series midget open fuse blocks||305|
CHM Series HEB Series TCFH Series
**==> picture [214 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
BM Series Modular R600 Series<br>Knifeblade<br>**----- End of picture text -----**<br>
|**1000 Volts**<br>**Fuses**|**Volts**|**Page**|
|---|---|---|
|10x38mm<br>PV-_A10|1000V|60|
|14x51mm<br>PV-_A14|1000/1100V|61|
|NH1<br>PV-_ANH|1000V|62|
|01XL<br>PV-_A-01XL<br>1XL<br>PV-_A-1XL<br>2XL<br>PV-_A-2XL|1000V<br>1000V<br>1000V|63<br>63<br>63|
|3L<br>PV-_A-3L|1000V|63|
|**Holders**<br>• CHPV Series 10x38 DIN-Rail mount holders|CHPV Series 10x38 DIN-Rail mount holders|274-277|
|• CH14 Series 14x51 DIN-Rail mount holders|CH14 Series 14x51 DIN-Rail mount holders|274-277|
|• HEB Series* 10x38 in-line holders||310|
|• SD1 Series** NH1 holders||63|
|* Self certified to 1000Vdc.|||
|** IEC only to 1000Vdc.|||
|**Blocks**|||
|• SD1XL-S Series 01XL & 1XL blocks||63|
|• SD2XL-S Series 2XL blocks||63|
|• SD3L-S Series 3L blocks||63|
**==> picture [226 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
CHPV Series CH14 Series HEB Series<br>C1 i<br>o*<br>SD1-D-PV Series SD1XL-S Series SD2XL-S Series<br>**----- End of picture text -----**<br>
**==> picture [53 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
SD3L-S Series<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**54**
**Solar Fuse Products**
## **Holders & Blocks For Branch Circuit Rated Fuses**
## **1500 Volts**
**1500 Volts Fuses Volts Page** 01XL PV-_A-01XL-15 1500V 63 1XL PV-_A-1XL-15 1500V 63 2XL PV-_A-2XL-15 1500V 63 3L PV-_A-3L-15 1500V 63 14x65mm PV-_A14* 1300/1500V 66
## **Blocks**
- SD1XL-S Series** 01XL & 1XL blocks 63
- • SD2XL-S Series** 2XL blocks 63 • SD3L-S Series** 3L blocks 63
SD1XL-S Series SD2XL-S Series SD3L-S Series
- Available with tags for bolt mounting or 10mm fixings for mounting in modular blocks for 10mm diameter fuses.
- ** IEC only to 1500Vdc.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**55**
**Solar Fuse Products**
## **13⁄32˝ x 1 1⁄2˝ Midget PV Fuses**
## **PVM**
**==> picture [324 x 324] intentionally omitted <==**
**----- Start of picture text -----**<br>
AMP<br>RATING<br>100<br>I SeSra eetigi a cet<br>10 SHH<br>as FA<br>1<br>STM NC<br>EE EE HH AAC Eee<br>.1 nim Ml<br>.01<br>CURRENT IN AMPS<br>5 A 8 A 10 A 15 A 20 A 30 A<br>TIME IN SECONDS<br>1 10 100 1,000<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** A range of UL 2579
fast-acting 600Vdc Midget fuses specifically designed to protect solor power systems in extreme ambient temperature, high cycling and low level fault current conditions (reverse current, multi-array fault). **Dimensions:**[13] ⁄32˝ x 1[1] ⁄2˝ (10.3 x 38.1mm).
## **Ratings:**
Volts — 600Vdc to UL 2579
Amps — 4-30A IR — 50kA DC (4-30A)
**Agency Information:** UL Listed 2579, Guide JFGA, File E335324, CSA Component Certified C22.2.
## **Features and Benefits**
- Specifically designed to protect solar power systems in extreme ambient temperature per UL 2579 listed
- Capable of withstanding high cycling and low level fault current conditions
## **Typical Applications**
- Solar Combiner Boxes
- Solar String Protectors
## **Power Loss (Watts)**
|Catalog Amp Power Loss<br>Number|Catalog Amp Power Loss<br>Rating|Catalog Amp Power Loss(Watts)<br>0.8 x In<br>1.0 x In<br>1.04<br>1.86<br>1.00<br>1.72<br>1.65<br>2.91|
|---|---|---|
|||0.8 x In|
|PVM-10|10|1.04|
|PVM-15|15|1.00|
|PVM-30|30|1.65|
In = Rated current
## **Catalog Numbers (Amps)**
|PVM-4|PVM-7|PVM-10|PVM-20|
|---|---|---|---|
|PVM-5|PVM-8|PVM-12|PVM-25|
|PVM-6|PVM-9|PVM-15|PVM-30|
## **Dimensions - (mm)**
**==> picture [56 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.5"<br>±0.031<br>(38.1mm)<br>y<br>0.407"<br>±0.005<br>al (10.3mm)<br>**----- End of picture text -----**<br>
**==> picture [233 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Fuse Holders & Blocks For the PVM Fuse<br>**----- End of picture text -----**<br>
• See page 54
**Data Sheet: 2153**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**56**
**Solar Fuse Products**
## **Fast-Acting CUBEFuse™**
## **PVCF Class CF Fuse**
## **Features and Product Benefits**
- Maximize uptime and reliability using fuses designed and listed to UL 2579: _Low Voltage Fuses - Fuses for Photovoltaic Systems_ .
- Minimize chances of equipment failure and personnel injury when using full range fuses having the industry’s fastest response time to low-magnitude faults.
- Maximize return on investment with fuses proven to withstand harsh temperatures.
- Minimize design time, operating outage time and replacement cost with fuses qualified in excessively changing enviromental conditions.
- Simplify compatibility with readily available industry standard Class CF holders.
## Catalog Symbol: PVCF_RN
Fast-Acting Fuse: 6 minutes maximum clearing time at 200% rated current for 30 to 60A fuse
- 8 minutes maximum clearing time at 200% rated current for 70 to 100A fuse
## **Ratings:**
- Temperature Derating: Designed to maximize rated capacity in elevated environmental temperatures.
- Overload Protection: Proven to clear faults faster than the UL requirement.
- Power Loss: Minimal energy consumption leading to increased efficiency.
Volts — 600Vac (Photovoltaic applications)
- 300Vdc
Amps — 35-100A
IR — 300kA RMS Sym. (UL)
- 200kA RMS Sym. (CSA)
|**Fuse Catalog Numbers Non-Indicatin**|**Numbers Non-Indicatin**|**Numbers Non-Indicating (Amps)**|
|---|---|---|
|PVCF35RN|PVCF50RN|PVCF80RN|
|PVCF40RN|PVCF60RN|PVCF90RN|
|PVCF45RN|PVCF70RN|PVCF100RN|
- 50kA DC (UL & CSA)
## **Agency Information:**
- UL 2579 Listed Fuse: Guide JFGA, File E335324
- CSA Certified Fuse: Class C22.2
## **Other Ratings/Specifications:**
## Watts Loss at Rated Current: PVCF35RN: 5.45W
PVCF60RN: 7.27W PVCF100RN: 11.50W
## **Operating and Storage Temperature Range:** -40 to 90°C **Material Specifications:**
- Case: Glass filled PES (Polyethersulfone)
- Terminals: Copper alloy
- Terminal plating: Electroless tin
Scan this tag to get the latest product information for the New PVCF CUBEFuse.
## **Carton Quantity and Weight**
|Amp<br>Rating|Carton<br>Qty.|Weight Per Carton|Weight Per Carton|
|---|---|---|---|
|||lbs|kg|
|PVCF-35-60A|12|1.42|0.65|
|PVCF-70-100A|6|1.74|0.79|
• See pages 32 and 33
**Recommended Fuse Holders For Class CF Fuses**
**Data Sheet: 2155**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**57**
**Solar Fuse Products**
## **Fast-Acting CUBEFuse™**
## **PVCF_RN Dimensions – in (mm)**
——
|Fuse<br>Amps<br>~~A~~|Dimensions - in (mm)<br>~~A~~|Dimensions - in (mm)<br>~~A~~|Dimensions - in (mm)<br>~~A~~|Dimensions - in (mm)<br>~~A~~|Dimensions - in (mm)<br>~~A~~|Dimensions - in (mm)<br>~~A~~|Dimensions - in (mm)<br>~~A~~|
|---|---|---|---|---|---|---|---|
||A<br>~~A~~|B<br>~~A~~|C<br>~~A~~|D<br>~~A~~|E<br>~~A~~|F<br>~~A~~|G<br>~~A~~|
|35-40<br>~~A~~|2.13<br>(54.10)<br>~~A~~|1.00<br>(25.40)<br>~~A~~|1.13<br>(28.58)<br>~~A~~|0.36<br>(9.10)<br>~~A~~|0.04<br>(1.02)<br>~~A~~|0.63<br>(15.93)<br>~~A~~|0.38<br>(9.65)<br>~~A~~|
|45-50<br>~~A~~|2.13<br>(54.10)<br>~~A~~|1.00<br>(25.40)<br>~~A~~|1.13<br>(28.58)<br>~~A~~|0.44<br>(11.13)<br>~~A~~|0.04<br>(1.02)<br>~~A~~|0.63<br>(15.93)<br>~~A~~|0.38<br>(9.65)<br>~~A~~|
|60|2.13<br>(54.10)|1.00<br>(25.40)|1.13<br>(28.58)|0.44<br>(11.13)|0.04<br>(1.02)|0.63<br>(15.93)|0.38<br>(9.65)|
|70|3.01<br>(76.45)|1.00<br>(25.40)|1.26<br>(32.00)|0.49<br>(12.45)|0.06<br>(1.60)|0.58<br>(14.78)|0.38<br>(9.65)|
|80-90<br>~~ee~~|3.01<br>(76.45)<br>~~ee~~|1.00<br>(25.40)<br>~~ee~~|1.26<br>(32.00)<br>~~ee~~|0.49<br>(12.45)<br>~~ee~~|0.06<br>(1.60)<br>~~ee~~|0.58<br>(14.78)<br>~~ee~~|0.38<br>(9.65)<br>~~ee~~|
|100<br>~~ee~~|3.01<br>(76.45)<br>~~ee~~|1.00<br>(25.40)<br>~~ee~~|1.26<br>(32.00)<br>~~ee~~|0.57<br>(14.48)<br>~~ee~~|0.06<br>(1.60)<br>~~ee~~|0.58<br>(14.78)<br>~~ee~~|0.38<br>(9.65)<br>~~ee~~|
## **Time-Current Characteristic Curves–Average Melt**
## **Current Limitation Curves**
**==> picture [403 x 337] intentionally omitted <==**
**----- Start of picture text -----**<br>
100,000<br>1000<br>SSSSSSeet aerated te metal eect 10,000 meeeFHFHe<br>100<br>1,000<br>sth,Si<br>A<br>10 HAHA 100 SS a<br>PROSPECTIVE SHORT CIRCUIT CURRENT<br> SYMMETRICAL RMS AMPS<br>Ses ees ceueennt<br>CUBEFuse Holders<br>1 TAR Catalog Numbers<br>(amps) Fits Fuse Holder<br>oe eeee Non-Indicating TCFH60N TCFH100N<br>PVCF35RN X X<br>PVCF40RN X X<br>PVCF45RN X X<br>0.1 PVCF50RN X X<br>PVCF60RN X X<br>Se ee ee ee PVCF70RN X<br>PVCF80RN X<br>PVCF90RN X<br>PVCF100RN X<br>tN ==<br>0.01 AW<br>CURRENT IN AMPS<br>35A 40A 50A 60A 100A<br>INSTANTANEOUS PEAK LET THRU CURRENT IN AMPS<br>100 1,000<br>TIME IN SECONDS<br>1 10 100 1,000 10,000<br>**----- End of picture text -----**<br>
**==> picture [251 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>100,000 emer<br>100A<br>10,000 meeeFHFHe e e eee ee 60A 50A 40A 35A<br>1,000<br>A<br>100 SS a<br>PROSPECTIVE SHORT CIRCUIT CURRENT<br>INSTANTANEOUS PEAK LET THRU CURRENT IN AMPS<br>100 1,000 10,000 100,000 300,000<br>**----- End of picture text -----**<br>
**Data Sheet: 2155**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**58**
**Solar Fuse Products** aga
## **Limitron™ Fast-acting Fuses**
## **Time-Current Characteristic Curves—Average Melt**
## **PVS-R (600Vac/dc) Class RK5**
**==> picture [513 x 323] intentionally omitted <==**
**----- Start of picture text -----**<br>
30A 60A 100A 200A 400A<br>1000<br>Specifications<br>Description: A range of UL 2579 fast-acting<br>600Vdc Class RK5 fuses specifically<br>designed to protect solar power systems in Sets ee Seri ae<br>extreme ambient temperature, high cycling<br>and low level fault current conditions (reverse 100<br>current, multi-array fault).<br>Seti i<br>Dimensions: See page 15 for Class RK5<br>dimensions. [ee<br>Ratings:<br>Volts — 600Vac to UL 248-12 10<br>=<br>600Vdc to UL 2579<br>Amps — 20-400A<br>BEicl.<br>IR — 200kA RMS Sym. AC<br>20kA DC (20-60A)<br>10kA DC (70-400A) 1<br>Agency Information: UL Std. 248-12, Class RK5, UL<br>Pot VN ied<br>Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579,<br>CSA Component Certified C22.2. =o Aer<br>Features and Benefits 0.1<br>Current limitation for non-inductive circuits provides Class siti<br>RK5 current-limiting response to ground fault and<br>short-circuit conditions. eae EN eat<br>Designed for the protection and isolation of photovoltaic<br>systems. 0.01 aiime Seni eee meni<br> mi thi ml<br>Typical Applications<br>Current in Amps<br>Designed<br>to meet the new<br>UL Photovoltaic Fuse<br>Standard<br>Time in Seconds<br>10 100 1,000 10,000 100,000<br>**----- End of picture text -----**<br>
- Current limitation for non-inductive circuits provides Class RK5 current-limiting response to ground fault and short-circuit conditions.
- Designed for the protection and isolation of photovoltaic systems.
- Photovoltaic systems
- Inverters
- Solar DC Safety Switches
- Recombiner Boxes
## **Catalog Numbers (Amps)**
|PVS-R-20|PVS-R-70|PVS-R-175|
|---|---|---|
|PVS-R-25|PVS-R-80|PVS-R-200|
|PVS-R-30|PVS-R-90|PVS-R-225|
|PVS-R-35|PVS-R-100|PVS-R-250|
|PVS-R-40|PVS-R-110|PVS-R-300|
|PVS-R-50|PVS-R-125|PVS-R-350|
|PVS-R-60|PVS-R-150|PVS-R-400|
## **Recommended Fuse Holders & Blocks For Class RK5 Fuses**
• See page 19
**Data Sheet: 4203**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**59**
**Solar Fuse Products**
## **10x38mm Photovoltaic Fuses**
## **PV**
## **Dimensions - mm**
## **Specifications**
**Class:** gPV
**Description:** A range of fuses specifically designed for the protection and isolation of photovoltaic strings. **Dimensions:**[13] ⁄32” x 1[1] ⁄2” (10.3 x 38.1mm).
**Ratings:** Volts — 1000Vdc Amps — 1-20A IR — 33kAdc IR (Min) — 1.3 x In
**Agency Information:** CCC pending, UL Listed E335324, IEC 60269-6, UL 2579, CSA.
## **Features and Benefits**
- Capable of interrupting low over currents associated with faulted PV strings.
- High DC voltage rating.
- Variety of mounting options for flexibility.
## **Catalog Numbers (Amps)**
**Current Energy Integrals I[2] t (A[2] s) Watts Loss Part Number Rating (Amps) Pre-Arcing Total at 1000V 0.8 In In** ~~ee~~ PV-1A10F 1 0.15 0.4 0.8 1.5 ~~a~~ PV-2A10F ~~ee~~ 2 1.2 3.4 0.6 1.0 ~~ee~~ PV-3A10F 3 4 11 0.8 1.3 ~~a~~ PV-3-5A10F ~~ee~~ 3.5 6.6 18 0.9 1.4 PV-4A10F 4 9.5 26 1.0 1.5 ~~po | a~~ PV-5A10F ~~ee~~ 5 19 50 1.0 1.6 ~~ee~~ PV-6A10F 6 30 90 1.1 1.8 ~~a~~ PV-8A10F ~~ee~~ 8 3 32 1.2 2.1 ~~ee~~ PV-10A10F 10 7 70 1.2 2.3 ~~a~~ PV-12A10F ~~ee~~ 12 12 120 1.5 2.7 PV-15A10F 15 22 220 1.7 2.9 ~~a~~ PV-20A10F 20 34 350 2.1 3.6
## **Time-Current Characteristic Curves—Average Melt**
**Recommended Fuse Holders & Blocks For Class RK5 Fuses**
- See page 19
**Data Sheet: 720110**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**60**
**Solar Fuse Products** Baa
## **14x51mm Photovoltaic Fuses**
## **14x51mm**
## **Dimensions - mm**
## **Specifications**
**Description:** A range of 14x51mm package fuse links specifically designed for protecting and isolating photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault).
**Dimensions:** See dimension illustration. **Construction:** Melamine tube with silver fuse element.
## **Ratings:**
**Time-Current Characteristic Curves—Average Melt**
Rated Volts — 1000Vdc (25 & 32A)
1100Vdc (15 & 20A)
Rated Breaking Capacity: 10kA
Amps — 15-32A
**Agency Information:** UL Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579,IEC 60269-6 gPV, CSA. CCC pending.
## **Features and Benefits**
- Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems
- High DC voltage rating
- Demonstrated performance in extreme temperature cycling conditions
## **Typical Applications**
• Photovoltaic systems
## **Catalog Numbers**
|Part<br>Number<br>~~—}~~|Current<br>Rating<br>(Amps)<br>~~—}~~|Rated<br>Voltage|EnergyIntegrats I2t(A2s)|EnergyIntegrats I2t(A2s)|Watts Loss|Watts Loss|
|---|---|---|---|---|---|---|
||||Pre-Arcing|Total at Rated<br>Voltage|0.8In|In|
|PV-15A14F<br>~~—}~~<br>~~4}~~|15<br>~~—}~~<br>~~4}~~|1100Vdc<br>~~4}~~|14<br>~~4}~~|265<br>~~4}~~|2.1<br>~~4}~~|4|
|PV-20A14F<br>~~—}~~<br>~~4}~~|20<br>~~—}~~<br>~~4}~~||27<br>~~4}~~|568<br>~~4}~~|2.7<br>~~4}~~|5|
|PV-25A14F<br>~~—}~~<br>~~4}~~|25<br>~~—}~~<br>~~4}~~|1000Vdc<br>~~4}~~|65<br>~~4}~~|943<br>~~4}~~|2.7<br>~~4}~~|5.1|
|PV-32A14F<br>~~4}~~|32<br>~~4}~~||120<br>~~4}~~|1740<br>~~4}~~|3.3<br>~~4}~~|6.2|
**Available Current (Amps), DC-Time Constant 1-3ms**
## **Recommended Fuse Holders & Blocks For Class RK5 Fuses**
- See page 19
**Data Sheet: 720132**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**61**
**Solar Fuse Products**
## **NH1 Photovoltaic Fuses**
## **Specifications**
**Description:** A range of NH fuse links specifically designed for protecting and isolating photovoltaic array combiners and disconnects. These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault). **Dimensions:** See dimension illustration. **Construction:** Melamine tube with silver fuse element.
**Dimensions - mm Size 1**
## **Ratings:**
Rated Volts — 1000Vdc Rated Breaking Capacity: 50kA
Amps — 32-160A **Agency Information:** UL Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579,IEC 60269-6 gPV, CSA. CCC pending.
## **Features and Benefits**
- Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems
- High DC voltage rating
- Variety of mounting options for flexibility
**Time-Current Characteristic Curves—Average Melt**
- Demonstrated performance in extreme temperature cycling conditions
## **Typical Applications**
• Photovoltaic systems
- Inverters
## **Catalog Numbers**
|Part<br>Number|Current<br>Rating<br>(Amps)|EnergyIntegrats I2t(A2s)|EnergyIntegrats I2t(A2s)|Watts Loss|Watts Loss|
|---|---|---|---|---|---|
|||Pre-Arcing|Total at<br>1000V|0.8In|In|
|PV-32ANH1|32|80|720|4.3|8.5|
|PV-40ANH1|40|185|1670|4.6|9|
|PV-50ANH1|50|400|3600|5.4|10.5|
|PV-63ANH1|63|470|4300|6.1|12|
|PV-80ANH1|80|640|5760|7.9|15.5|
|PV-100ANH1|100|1300|11,700|8.4|16.5|
|PV-125ANH1|125|2600|23,400|8.9|17.5|
|PV-160ANH1|160|5200|46,800|12.2|24|
## **Recommended NH1 Fuse Holders - SD(size)-D**
**Available Current (Amps), DC-Time Constant 1-3ms**
• See page 54
**Data Sheet: 720133**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**62**
**Solar Fuse Products**
## **XL Photovoltaic Fuses**
## **1000Vdc XL Style Photovoltaic Fuses**
## **Features and Benefits**
- Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems
- High DC voltage rating
- Variety of mounting options for flexbility
- Demonstrated performance in extreme temperature cycling conditions
## **Typical Applications**
- Photovoltaic systems
- Inverters
## **Recomended Fuse Holders**
- SD1XL-S (suitable for 01 and 1XL)
- SD2XL-S (suitable for 2XL)
- SD3L-S (suitable for 3L)
## **Specifications**
**Description:** A range of XL package fuses specifically designed for protecting and isolating photovoltaic array combiners and disconnects.
These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault).
**Dimensions:** See dimension illustration.
## **Ratings:**
Volts — 1000Vdc
Amps — 63 to 630A:
IR — 50kA @ 63 to 160A
— 33kA @ 200 to 315A
— 50kA @ 350 to 630A
**Agency Information:** — IEC 60269-6
**See Data Sheet 720146 for information on the SD__-S Fuse Holders.**
— RoHS compliant
— UL 2579
— CSA
— CCC (pending
|Part Number/Style<br>~~**e**~~<br>~~e~~<br>~~ee~~<br>~~ee~~|Part Number/Style<br>~~**e**~~<br>~~e~~<br>~~ee~~<br>~~ee~~|Body<br>Size<br>~~**e**~~<br>~~e~~<br>||Current<br>Rating (Amps)<br>~~**e**~~<br>||Volts<br>~~**e**~~f|Energy Integrals I2t (A2s)<br>f<br>~~es~~<br>~~ee~~|Energy Integrals I2t (A2s)<br>f<br>~~es~~<br>~~ee~~|Watts Loss<br>f<br>~~es~~<br>~~ee~~|Watts Loss<br>f<br>~~es~~<br>~~ee~~|
|---|---|---|---|---|---|---|---|---|
|Bladed<br>~~**e**~~<br>~~e~~<br>~~ee e~~<br>~~ee~~|Bolted<br>~~**e**~~<br>~~ee~~<br>~~ee~~||||Pre-Arcing<br>f<br>~~es~~<br>~~es ee~~|Total@1000V<br>f<br>~~es~~<br>~~ee~~<br>~~ee~~|0.8In<br>f<br>~~es~~<br>~~ee~~<br>ee|In<br>f<br>~~es~~|
|PV-63A-01XL<br>~~e~~<br>~~ee e~~<br>~~ee~~<br>ee|PV-63A-01XL-B<br>~~ee~~<br>~~ee~~<br>**e**~~**e**~~|01<br>~~e~~<br>|<br>~~**e**~~<br>**|**<br>~~**|**~~|63<br>|<br>**|**|1000Vdc<br>~~GQ~~|350<br>~~es~~<br>~~es ee~~<br>**e**see|2520<br>~~es~~<br>~~ee~~<br>~~ee~~<br>eeee|12<br>~~es~~<br>~~ee~~<br>ee<br>ee|24<br>~~es~~|
|PV-80A-01XL<br>~~ee e~~<br>~~ee~~<br>ee<br>ee|PV-80A-01XL-B<br>~~ee~~<br>**e**~~**e**~~<br>||80<br>|<br>**|**||660<br>~~es ee~~<br>**e**see|4752<br>~~ee~~<br>~~ee~~<br>eeee<br>~~e~~<br>ee|14<br>~~ee~~<br>ee<br>ee<br>~~e~~<br>ee|27<br>~~e~~|
|PV-100A-01XL<br>~~e~~<br>~~ee~~<br>ee<br>ee<br>~~ee~~|PV-100A-01XL-B<br>~~ee~~<br>**e**~~**e**~~<br>~~ee~~||100<br>|<br>**|**<br>~~**|**~~||1350<br>~~es ee~~<br>**e**see<br>~~**e**s~~|9720<br>~~ee~~<br>eeee<br>~~e~~<br>ee<br>~~ee~~|15<br>ee<br>ee<br>~~e~~<br>ee<br>~~ee~~|30<br>~~e~~|
|PV-125A-01XL<br>ee<br>ee<br>~~ee~~|PV-125A-01XL-B<br>**e**~~**e**~~<br>~~ee~~||125<br>**|**<br>~~**|**~~||1930<br>**e**see<br>~~**e**s~~<br>~~e ee~~|13,896<br>eeee<br>~~e~~<br>ee<br>~~ee~~<br>~~ee~~|20<br>ee<br>~~e~~<br>ee<br>~~ee~~<br>~~ee~~|40<br>~~e~~|
|PV-160A-01XL<br>ee <br>~~ee~~<br>~~ee~~|PV-160A-01XL-B<br> ~~ee~~||160<br>~~**|**~~<br>~~G~~||3900<br>~~**e**s~~<br>~~e ee~~<br>~~Q~~|28,080<br>ee <br>~~ee~~<br>~~ee~~|25<br> ee<br>~~ee~~<br>~~ee~~|44|
|PV-200A-1XL<br> <br>~~ee~~<br>~~es~~<br>~~ee~~<br>~~ee~~|PV-200A-1XL-B<br> ~~ee~~<br>~~es~~<br>~~ee~~|1<br>~~**|**~~<br>~~es~~<br>||200<br>~~**|**~~<br>~~es~~<br>~~G~~<br>||1000Vdc<br>~~es~~<br>~~GQ~~|9400<br>~~**e**s ~~<br>~~e ee~~<br>~~es~~<br>~~Q~~<br>~~ee ee~~|27,260<br> ~~ee~~<br>~~ee~~<br>~~es~~<br>~~ee~~|31<br>~~ee~~<br>~~ee~~<br>~~es~~<br>es|60<br>~~es~~|
|PV-200A-2XL<br>~~ee~~<br>~~ee~~<br>~~ee~~|PV-200A-2XL-B<br>~~ee~~<br>~~ee~~|2<br>|<br>~~|~~<br>~~e~~<br>**|**|200<br>~~G~~<br>|<br>~~|~~|1000Vdc<br>~~GQ~~|4152<br>~~Q~~<br>~~ee ee~~<br>~~es~~|31,000<br>~~ee~~<br>~~ee~~|29<br>es<br>~~ee~~|62|
|PV-250A-2XL<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~a~~|PV-250A-2XL-B<br>~~ee~~<br>~~ee~~<br>~~ee~~||250<br>~~G~~<br>|<br>~~|~~<br>~~|~~||7721<br>~~Q~~<br>~~ee ee~~<br>~~es~~<br>~~ee ee~~|57,000<br>~~ee~~<br>~~ee~~<br>~~ee~~|35<br>es<br>~~ee~~<br>~~ee~~|70|
|PV-315A-2XL<br>~~ee~~<br>~~ee~~<br>~~a~~<br>~~ee~~|PV-315A-2XL-B<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~~~**e**~~||315<br>|<br>~~|~~<br>~~|~~<br>**|**||17,600<br>~~ee ee~~<br>~~es~~<br>~~ee ee~~<br>~~**e**e~~|130,000<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|40<br>es<br>~~ee~~<br>~~ee~~<br>ee|75<br>e~~e~~|
|PV-350A-3L<br>~~ee~~<br>~~a~~<br>~~ee~~<br>ee|PV-350A-3L-B<br>~~ee~~<br>~~ee~~<br>~~ee~~~~**e**~~<br>e|3<br>~~|~~<br>~~e ~~<br>**|**<br>|<br>||350<br>~~|~~<br> ~~|~~<br>**|**|1000Vdc|30,885<br>~~es~~<br>~~ee ee~~<br>~~**e**e~~|160,700<br>~~ee ~~<br>~~ee~~<br>~~ee~~<br>~~s~~<br>ee|41<br> ~~ee~~<br>~~ee~~<br>ee<br>~~s~~<br>ee|90<br>e~~e~~<br>~~s~~|
|PV-400A-3L<br>~~ee~~<br>ee<br>ee|PV-400A-3L-B<br>~~ee~~~~**e**~~<br>e<br>ee||400<br>**|**<br>|||44,000<br>~~**e**e~~<br>~~es~~|230,000<br>~~ee~~<br>~~s~~<br>ee<br>~~es~~<br>**e**e|63<br>ee<br>~~s~~<br>ee<br>~~es~~<br>ee|100<br>e~~e~~<br>~~s~~<br>~~es~~|
|PV-500A-3L<br>~~ee~~<br>ee<br>ee|PV-500A-3L-B<br>~~ee~~~~**e**~~<br>e<br>ee<br>ee||500<br>**|**<br>|<br>|||48,300<br>~~**e**e ~~<br>~~es~~<br>ee|251,200<br> ~~ee~~ <br>~~s~~<br>ee<br>~~es~~<br>**e**e<br>e|71<br> ee <br>~~s~~<br>ee<br>~~es~~<br>ee<br>ee|138<br> e~~e~~<br>~~s~~<br>~~es~~|
|PV-630A-3L<br>ee<br>ee|PV-630A-3L-B<br>ee<br>ee||630<br>|<br>|||100,000<br>~~es~~<br>ee|520,000<br>ee<br>~~es~~<br>**e**e<br>e|92<br>ee<br>~~es~~<br>ee<br>ee|180<br>~~es~~|
**Data Sheet: 720134**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**63**
**Solar Fuse Products**
## **XL Photovoltaic Fuses for Solar Applications**
## **Dimensions - mm (not to scale)**
## **01XL Blade Size**
## **01XL Bolt Size**
## **1XL Blade Size**
## **1XL Bolt Size**
## **2XL Blade Size**
## **2XL Bolt Size**
## **3L Blade Size**
## **3L Bolt Size**
**Data Sheet: 720134**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**64**
**Solar Fuse Products** a
**Time Current Curves for 01XL and 1XL Time Current Curves for 2XL**
## **XL Photovoltaic Fuses for Solar Applications**
## **Available Current (Amps), DC-Time Constant 1-3ms**
**Available Current (Amps), DC-Time Constant 1-3ms**
**Time Current Curves for 3L**
**Available Current (Amps), DC-Time Constant 1-3ms**
**Data Sheet: 720134**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**65**
**Solar Fuse Products**
## **14x65mm Photovoltaic Fuses**
## **Specifications**
**Description:** A range of 14x65mm package fuse links specifically designed for protecting and isolating photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault). **Dimensions:** See dimension illustration. **Construction:** Melamine tube with silver fuse element.
## **Ratings:**
Rated Volts — 1300Vdc (25 & 32A) 1500Vdc (15 & 20A)
Rated Breaking Capacity: 10kA Amps — 15-32A
## **Dimensions - mm**
**Cylindrical PV - (amp rating) A14LF**
**==> picture [291 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cylindrical with Tags PV - (amp rating) A14L-T<br>90.07<br>88.07<br>77.12<br>75.12 15.22<br>69.34 15.02<br>67.34<br>|<br>Sf. 4.70 Te @<br>10.99<br>**----- End of picture text -----**<br>
**Agency Information:** UL Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579,IEC 60269-6 gPV, CSA. CCC pending.
## **Features and Benefits**
- Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems
- High DC voltage rating
- Demonstrated performance in extreme temperature cycling conditions
## **Typical Applications**
• Photovoltaic systems **Catalog Numbers**
**==> picture [221 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cylindrical with 10mm Fixings PV - (amp rating)<br>A14LF10F<br>86.77<br>84.77<br>14.22<br>14.02<br>Hoge<br>10.25 10.05<br>**----- End of picture text -----**<br>
|**Part Number**|**Part Number**|**Part Number**|**Current**<br>**Rating**<br>**(Amps)**|**Rated**<br>**Voltage**|**Energy Integrats Iat (A2s)**|**Energy Integrats Iat (A2s)**|**Watts Loss**|**Watts Loss**|
|---|---|---|---|---|---|---|---|---|
|**Cylindrical**|**Cylindrical**<br>**with Tags**|**Cylindrical with**<br>**10mm Fixings**|||**Energy Integrats I**<br>**Pre-Arching**|**Energy Integrats It (As)**<br>**Total at**<br>**Rated Voltage**|**0.8 In**|**In**|
|PV-15A14LF|**with Tags**<br>PV-15A14L-T|**10mm Fixings**<br>PV-15A14LF10F|**(Amps)**<br>15|1500Vdc|14|**Rated Voltage**<br>160|3.2|5.8|
|PV-20A14LF|PV-20A14L-T|PV-20A14LF10F|20||34|400|3.6|6.5|
|PV-25A14LF|PV-25A14L-T|PV-25A14LF10F|25|1300Vdc|65|550|4.1|7.5|
|PV-32A14LF|PV-32A14L-T|PV-32A14LF10F|32||105|900|5.7|10.4|
## **Time-Current Characteristic Curves—Average Melt**
Available Current (Amps), DC-Time Constant 1-3ms
**Data Sheet: 720139**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**66**
**Solar Fuse Products**
## **XL Photovoltaic Fuses**
## **1500Vdc XL Style Photovoltaic Fuses**
**Agency Information:** UL Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579, IEC 60269-6 gPV, CSA. CCC pending.
## **Features and Benefits**
- Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems
- High DC voltage rating
- Variety of mounting options for flexbility
- Demonstrated performance in extreme temperature cycling conditions
## **Typical Applications**
- Photovoltaic systems
- Inverters
## **Recomended Fuse Holders**
- SD1XL-S (suitable for 01 and 1XL)
- SD2XL-S (suitable for 2XL)
- SD3L-S (suitable for 3L)
## **Specifications**
**Description:** A range of XL package fuses specifically designed for protecting and isolating photovoltaic array combiners and disconnects.
These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault).
**Dimensions:** See dimension illustration.
## **Ratings:**
Volts — 1200Vdc (160A)
— 1500Vdc (50-125A, 200-400A) Amps — 63 to 400A:
IR — 33kA
**See Data Sheet 720146 for information on the SD__-S Fuse Holders.**
|Part Number/Style<br>~~—~~<br>~~|~~<br>~~es~~|Part Number/Style<br>~~—~~<br>~~|~~<br>~~es~~|Body<br>Size<br>~~|~~<br>||Current<br>Rating (Amps)<br>~~|~~<br>||Volts|Energy Integrals I2t (A2s)<br>~~ee~~|Energy Integrals I2t (A2s)<br>~~ee~~|Watts Loss<br>~~ee~~|Watts Loss<br>~~ee~~|
|---|---|---|---|---|---|---|---|---|
|Bladed<br>~~—~~<br>~~es~~<br>~~ee~~|Bolted<br>~~|~~<br>~~ee~~||||Pre-Arcing<br>~~ee~~<br>~~ee~~|Total@1000V<br>~~ee~~<br>~~ee~~|0.8In<br>~~ee~~<br>~~ee~~|In<br>~~ee~~|
|PV-50A-01XL-15<br>~~—~~<br>~~es~~<br>~~ee~~|PV-50A-01XL-B-15<br>~~|~~<br>~~ee~~|01<br>~~|~~<br>|<br>~~aa~~<br>~~a~~<br>~~e~~|50<br>~~|~~<br>||1500Vdc<br>~~aa~~<br>~~a~~|280<br>~~ee~~<br>~~ee~~|1450<br>~~ee~~<br>~~ee~~|6<br>~~ee~~<br>~~ee~~|26<br>~~ee~~|
|PV-63A-01XL-15<br>~~ee~~<br>~~aa~~|PV-63A-01XL-B-15<br>~~ee~~<br>~~aa~~||63<br>|<br>~~aa~~||420<br>~~ee ~~<br>~~aa~~|2250<br> ~~ee~~ <br>~~aa~~|17<br> ~~ee~~<br>~~aa~~|28<br>~~aa~~|
|PV-80A-01XL-15<br>~~a~~|PV-80A-01XL-B-15<br>~~a~~<br>e~~e~~||80<br>~~a~~||950<br>~~a~~<br>a<br>ee|5000<br>ee|18<br>ee|30<br>ee|
|PV-100A-01XL-15<br>es|PV-100A-01XL-B-15<br>es<br>e~~e~~||100||1250<br>ee|6500<br>ee|22<br>ee|38<br>ee|
|PV-125A-01XL-15<br>a|PV-125A-01XL-B-15<br>e~~e~~<br>a||125||2200<br>ee<br>ee|11,500<br>ee<br>ee|27<br>ee<br>ee|48<br>ee<br>ee|
|PV-160A-01XL-12<br>a|PV-160A-01XL-B-12<br>a||160|1200Vdc|5000|19,500|24|48|
|PV-100A-1XL-15<br>~~a~~|PV-100A-1XL-B-15<br>~~a~~|1<br>~~aa~~<br>~~a~~<br>|100|1500Vdc<br>~~aa~~<br>~~a~~|1250<br>~~a~~|6000<br>~~a~~|24<br>~~a~~|43<br>~~a~~|
|PV-125A-1XL-15<br>~~aa~~|PV-125A-1XL-B-15<br>~~aa~~||125<br>~~aa~~||1950<br>~~aa~~|9360<br>~~aa~~|25<br>~~aa~~|52<br>~~aa~~|
|PV-160A-1XL-15<br>~~a~~|PV-160A-1XL-B-15<br>~~a~~||160<br>~~a~~||4200<br>~~a~~<br>a|20,160|30|58|
|PV-200A-1XL-15<br>a<br>~~ee~~|PV-200A-1XL-B-15<br>a<br>~~eee~~||200<br>~~|~~||9400<br>a<br>~~ee~~|45,120<br>~~ee~~|31<br>~~ee~~|61|
|PV-125A-2XL-15<br>~~ee~~|PV-125A-2XL-B-15<br>~~eee~~|2<br> <br>~~aa~~<br>~~a~~<br>|125<br>~~|~~|1500Vdc<br>~~aa~~<br>~~a~~|2200<br>~~ee~~|11,000<br>~~ee~~|23<br>~~ee~~|43|
|PV-160A-2XL-15<br>~~ee ~~<br>~~aa~~|PV-160A-2XL-B-15<br> ~~eee ~~<br>~~aa~~||160<br> ~~|~~<br>~~aa~~||5000<br>~~ee ~~<br>~~aa~~|25,000<br> ~~ee~~<br>~~aa~~|26<br>~~ee~~<br>~~aa~~|50<br>~~aa~~|
|PV-200A-2XL-15<br>~~a~~|PV-200A-2XL-B-15<br>~~a~~||200<br>~~a~~||9300<br>~~a~~<br>a|36,000|28|56|
|PV-250A-2XL-15<br>a<br>~~ee~~|PV-250A-2XL-B-15<br>a<br>~~eee~~||250<br>~~|~~||13,700<br>a<br>~~ee~~|68,000<br>~~ee~~|38<br>~~ee~~|72|
|PV-250A-3L-15<br>~~ee~~|PV-250A-3L-B-15<br>~~eee~~|3<br> <br>~~e~~|250<br>~~|~~|1500Vdc|20,000<br>~~ee~~|61,000<br>~~ee~~|35<br>~~ee~~|62|
|PV-315A-3L-15<br>~~ee ~~<br>~~a~~|PV-315A-3L-B-15<br> ~~eee ~~<br>~~a~~<br>e~~e~~||315<br> ~~|~~||38,000<br>~~ee ~~<br>a<br>~~ee~~|116,000<br> ~~ee~~<br>~~ee~~|40<br>~~ee~~<br>~~ee~~|72<br>~~ee~~|
|PV-355A-3L-15<br>es|PV-355A-3L-B-15<br>es<br>e~~e~~||355||44,000<br>~~ee~~|136,000<br>~~ee~~|46<br>~~ee~~|84<br>~~ee~~|
|PV-400A-3L-15<br>ee|PV-400A-3L-B-15<br>e~~e~~<br>ee||400||58,000<br>~~ee~~<br>ee|177,000<br>~~ee~~<br>ee|50<br>~~ee~~<br>ee|91<br>~~ee~~<br>ee|
**Data Sheet: 720134**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**67**
**Solar Fuse Products**
## **XL Photovoltaic Fuses**
**Dimensions - mm Bladed - Size 01XL, 1XL, 2XL and 3L**
|Size|a<br>~~a~~<br>~~es~~|b<br>~~ee~~<br>~~es~~|c<br>~~ee~~<br>~~Gs~~|d<br>~~es~~<br>~~Gs~~|e<br>~~ee~~|f<br>~~es~~|g<br>~~es~~|h|i|j|
|---|---|---|---|---|---|---|---|---|---|---|
|01XL|193.8<br>~~a~~<br>~~es~~<br>~~es~~|127.8<br>~~ee~~<br>~~es~~|124.6<br>~~ee~~<br>~~Gs~~<br>~~es~~|128.6<br>~~es~~<br>~~Gs~~<br>~~es~~|20<br>~~ee ~~<br>~~es~~|7.9<br> ~~es~~|43<br>~~es~~|40.4|21.3|5.8|
|1XL|189.8<br>~~es~~<br>~~es~~|127.8<br>~~es ~~|119.6<br> ~~Gs~~<br>~~es~~|123.6<br>~~Gs~~<br>~~es~~|20<br>~~es~~|13.4|51|39.8|20|5.8|
|2XL|204.5<br>~~es~~<br>~~ee~~|128.5<br>ee|119.3<br>~~es~~<br>es~~es~~|123.3<br>~~es ~~<br>~~es~~|26<br> ~~es~~|14.38|59.2|47.9|20|5.8|
|3L|204.9<br>~~ee~~|127.5<br>ee|118.3<br>es~~es~~|122.3<br>~~es~~|32.3|18.7|73.5|60|22|6|
**Bladed - Size 01XL, 1XL, 2XL and 3L**
|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|Size<br>a<br>b<br>c<br>d<br>e<br>f<br>g<br>h<br>i<br>01XL<br>187.6<br>127.8<br>6<br>43<br>58.3<br>164.3<br>150.3<br>10.4<br>20<br>1XL<br>183.6<br>127.8<br>6<br>51<br>66.3<br>160.3<br>146.3<br>10.4<br>20<br>2XL<br>191.3<br>128.5<br>6<br>59.2<br>74.5<br>167.8<br>154.8<br>10.5<br>25<br>~~==========~~|
|---|---|---|---|---|---|---|---|---|---|---|---|
||**Bladed - Size 01XL, 1XL, 2XL and 3L**||||**Bladed - Size 01XL, 1XL, 2XL and 3L**|||||||
||e|[= ||4||||||-|||
|||JEcall|_~-.]]]||||||||||
|||=<br>d<br>—|Adapter|||||||||
|||||||ee||ee||||
|||Size<br>a|b||c|d|e|f|g|h||
|||3L<br>199.7|128.5||6|73.5|88.8|169.7|10.5|30||
**Data Sheet: 720134**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**68**
**Solar Fuse Products** aa
## **XL Photovoltaic Fuses**
## **Time Current Curves for 01XL - 1500Vdc**
## **Time Current Curves for 1XL - 1500Vdc**
Available Current (Amps), DC-Time Constant 1-3ms
**==> picture [186 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Available Current (Amps), DC-Time Constant 1-3ms<br>**----- End of picture text -----**<br>
## **Time Current Curves for 2XL - 1500Vdc**
**==> picture [186 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Available Current (Amps), DC-Time Constant 1-3ms<br>**----- End of picture text -----**<br>
**Time Current Curves for 3L - 1500Vdc**
**==> picture [210 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Available Current (Amps), DC-Time Constant 1-3ms<br>**----- End of picture text -----**<br>
**Data Sheet: 720134**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**69**
## easyID™ fuses and fuse holders
Find blown fuses fast and easy. Utilize LED technology to indicate a blown fuse.
**70**
## **Low Voltage Supplementary Fuses**
## **RED indicates NEW information**
## **Section Contents**
## **Page**
|**Fuse Holder & Block Selection Guide . . . . . 72-73**|
|---|
|**Cable limiters & welder limiters**|
|K Series cable limiters . . . . . . . . . 600V . . . . . . . . . . 74|
|64000 & 68000 welder limiters . . . 600V . . . . . . . . . . 74|
|**13⁄32˝ x 11⁄2˝ Fast-acting supplementary fuses**|
|BAF . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . 75|
|KTK . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 75|
|KLM . . . . . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . 75|
|**13⁄32˝ x 11⁄2˝ Time-delay supplementary fuses**|
|FNM . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . 76|
|FNQ . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . 76|
|**13⁄32˝ x 13⁄8˝ Fast-acting supplementary fuses**|
|BBS . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 77|
|**Pin indication fuses and actuator**|
|GBA . . . . . . . . . . . . . . . . . . . . . . 125V . . . . . . . . . . 78|
|GLD . . . . . . . . . . . . . . . . . . . . . . 125V . . . . . . . . . . 78|
|MIC . . . . . . . . . . . . . . 250V fast-acting. . . . . . . . . . . 78|
|MIN . . . . . . . . . . . . . . 250V fast-acting . . . . . . . . . . . 78|
|FNA . . . . . . . . . . . . . . 250V time-delay . . . . . . . . . . 78|
|MIS . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 79|
|KAZ . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 79|
|**Limiters**|
|ANN . . . . . . . . . . . . . . 125V fast-acting . . . . . . . . . 79|
|ANL . . . . . . . . . . . . . . 80Vdc time-delay . . . . . . . . . 79|
|4164 & 4164-FR . . . . . . . . . .fuse blocks . . . . . . . . . 79|
|**In-line size rejecting fuses and fuse holders**|
|GLQ . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 80|
|GMQ . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 80|
|**In-line non-rejecting fuses and fuse holders**|
|GLR . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 81|
|GMF . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 81|
|GRF . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 81|
|**Automotive blade-type fuses**|
|ATC . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 82|
|ATC-_ID . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 82|
|ATM . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . .<br>82|
|ATM-_ID . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . 82|
|ATM-LP . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 82|
|MAX . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . .<br>83|
|MAX-_ID . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . 83|
|**Automotive blade-type fuse holders**|
|HHC, HHD, HHF, HHG, ATC-FHID for ATC fuses . . . . 82|
|HHL, HHM, ATC-FHID for ATM fuses . . . . . . . . . . . . . 83|
|HHX for MAX fuses . . . . . . . . . . . . . . . . . . . . . . . . . . 83|
|PCB fuseclips for ATC/ATM blade, 5mm,1⁄4˝ &13⁄32˝|
|diameter fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84|
**71**
**Low Voltage Supplementary Fuses**
## **Holders & Blocks for Low Voltage Supplementary Fuses**
## **Limiters**
|**Catalog Number**<br>**Volts**<br>**Page**|
|---|
|K Series . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 74|
|68000 Series . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 74|
|64000 Series . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 74|
|ANN Fast acting limiter . . . . . . . . . 125Vac/80Vdc . . . . . . . . . . . . 79|
|ANL Time-delay limiter . . . . . . . . . 80Vdc . . . . . . . . . . . . . . . . . . 79|
## **Holders**
- CH Series Class J modular 1 to 3-pole, panel/DIN rail mount . .283
CH Series Safety J™ Modular H250 Series Series Type
- Safety J™ Series modular holders, panel/DIN rail mount . . . . .288
## **Blocks**
- Modular Type Fuse Blocks 250/600V, panel mount . . . . . . . . . 311
- • H250 Series 1- to 3-pole 250V, panel mount . . . . . . . . . . . . . .296
- H600 Series 1- to 3-pole 600V, panel mount . . . . . . . . . . . . . .299
## **Blocks**
- Modular Knifeblade Fuse Blocks 250/600V, panel mount . . . . 291
- • Modular Type Fuse Blocks 600V, panel mount . . . . . . . . . . . . 311 • J600 Series, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
**==> picture [241 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Modular Knifeblade H600 Series J600 Series<br>**----- End of picture text -----**<br>
- JP Series pyramid blocks, panel mount . . . . . . . . . . . . . . . . . 304
- BH Series modular-style open blocks, panel mount . . . . . . . . 311
## **Limiter Blocks - ANN & ANL**
- Blocks for 4164 & 4164-FR . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
**==> picture [231 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
JP Series BH Series 4164 & 4164-FR<br>**----- End of picture text -----**<br>
## **13⁄32˝ X 1 1⁄2˝ Fuses**
|**Catalog Number**<br>**Volts**<br>**Page**|
|---|
|BAF . . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . 75|
|KTK . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 75|
|KLM. . . . . . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . . . . . . . . . . 75|
|FNM . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . 76|
|FNQ . . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . . . . . . . . . . 76|
## **Holders**
- OPM-NG-SC3 3-pole, panel/DIN-Rail mount . . . . . . . . . . . . . . .286
- OPM-1038R 3-pole, panel/DIN-Rail mount . . . . . . . . . . . . . . . .285
- OPM-1038RSW 3-pole w/ switch, panel/DIN-Rail mount . . . . .284
- CH Series Global 1- to 3-pole, DIN-Rail mount . . . . . . . . . . . . .276
- HPG Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . . . .322
- HPC-D Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . .323
- • HPM Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . . .323 • HPS Series Panel mount fuse holder . . . . . . . . . . . . . . . . . . . .322
- HPF Series Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . 322
- HEB Series 1-Pole in-line fuse holder . . . . . . . . . . . . . . . . . . . .315
- HEX & HEY Series 2-Pole in-line fuse holders . . . . . . . . . . . . . 315
- NDNF1-WH Fuse holding rail mount terminal block . . . . . . . . . 327
## **Blocks**
- BM Series, panel/DIN-Rail with adapters . . . . . . . . . . . . . . . . . 310
- 3723, 3742 and 3743 multi-pole add-on fuse blocks . . . . . . . . 326
**==> picture [238 x 239] intentionally omitted <==**
**----- Start of picture text -----**<br>
OPM-NG-SC3 OPM-1038R & CH Series<br>OPM-1038RSW<br>2€ HPG oa HPM<br>HPC-D<br>HPS HPF HEB Series<br>oh "<br>a! a:<br>HEX & HEY NDNF1-WH BM Series<br>Series<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**72**
**Low Voltage Supplementary Fuses**
## **Holders & Blocks for Low Voltage Supplementary Fuses**
## **13⁄32˝ X 1 3⁄8˝ Fuses**
## **Catalog Numbers**
**Catalog Numbers Volts Page** BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 77
## **Holder**
- HPS-L Panel mount holder . . . . . . . . . . . . . . . . . . . . . . . . . . .322
## **Blocks**
- BM Series, panel/DIN rail with adapters . . . . . . . . . . . . . . . . . .310
**==> picture [156 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
HPS-L BM Series<br>**----- End of picture text -----**<br>
- 3723, 3742 and 3743 multi-pole add-on fuse blocks . . . . . . . .326
## **Pin Indicating Fuses**
|**1⁄4˝ X 11⁄4˝ Fuse Catalog Numbers**<br>**Volts**<br>**Page**|
|---|
|GBA1⁄4" X 11⁄4" . . . . . . . . . . . . . . . . . . . . .125V . . . . . . . . . . . . . . .78<br>GLD1⁄4" X 11⁄4" . . . . . . . . . . . . . . . . . . . . .125V . . . . . . . . . . . . . . .78<br>MIC13⁄32" X 11⁄2" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 78<br>MIN13⁄32" X 11⁄2" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 78<br>FNA13⁄32" X 11⁄2" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 78<br>MIS13⁄32" X 2" . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 79<br>KAZ13⁄32" X 2" . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 79|
## **Holders**
- 1⁄4" X 1 1⁄4": HLD Panel mount visual indication . . . . . . . . . . . . .321
- 1⁄4" X 1 1⁄4": HK Series Panel mount lamp indicating . . . . . . . . . .321
## **Blocks**
- 1⁄4" X 1 1⁄4": Series 8000 for visual indication . . . . . . . . . . . . . . .324
- 13⁄32" X 1 1⁄2": 1-Pole signal block cat. # 3839 (not shown in catalog)*
- 13⁄32" X 2": 1-Pole signal block cat. # 2778 (not shown in catalog)*
**==> picture [16 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
HLD<br>**----- End of picture text -----**<br>
**==> picture [156 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
<< HK Series<br>Series 8000 dee<br>**----- End of picture text -----**<br>
- 13⁄32" X 2": 2-Pole signal block cat. # 2837 (not shown in catalog)*
- 13⁄32" X 2": 3-Pole signal block cat. # 2838 (not shown in catalog)*
- *Call our customer satisfaction team at 636-527-3877 for more information.
## **Automotive Blade-type Fuses**
## **Catalog Numbers Volts Page**
ATC . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . . . . . . 82 ATM . . . . . . . . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . . . . . . 82 MAX . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 83
## **Holders**
- ATC: HHC, HHD, HHF, HHG & ATC-FHID In-line holders . . . . . . 82
- ATM: HHL, HHM & ATM-FHID In-line holders . . . . . . . . . . . . . 83
- • MAX: HHX In-line holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
easyID™ HHC, HHD, HHF HHL & HHM HHX Illuminating Holders & HHG
## **In-Line Rejecting and Non-Rejecting Fuses**
## **Catalog Number**
**Volts Page**
GLQ rejecting fuse . . . . . . . . . . . . . . . . .300V . . . . . . . . . . . . . . . 80 GMQ rejecting fuse . . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 80 GLR non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 81 GMF non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 81 GRF non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 81
## **Holders**
- GLQ & GMQ: HLQ Rejection holder . . . . . . . . . . . . . . . . . . . . . 80
- GLR, GMF & GRF: HLR & HLR-2A non-rejection holders . . . . . .81
HLQ[3 ] Fuse Holders
HLR Fuse Holder
For product data sheets, visitwww.cooperbussmann.com/DatasheetsEle
**73**
**Low Voltage Supplementary Fuses**
## **Cable Limiters & Welder Limiters**
## **K Series**
## **64000 & 68000 Series**
## **Specifications**
## **Specifications**
**Description:** Cable limiters.
**Description:** Welder limiters.
## **Ratings:**
**Ratings:** Volts — 600Vac (or less) IR — 200kA RMS Sym.
Volts — 600Vac IR — 200kA RMS Sym. @ 600Vac
**Agency Information:** UL Listing: KDM, KDR, KDP and KFM, KCM, KCM-B and KCR.
## **Features and Benefits**
- Current-limiting devices designed specially for use on welder circuits only
- Time-current characteristics are designed to hold on the intermittent overloading encountered in welder operation, while providing short-circuit protection to the circuit and equipment
## **Features and Benefits**
- Sizes and ratings available to meet many applications.
- Welder limiters have excess current capacity in the operating range as needed for this type of service
## **Typical Applications**
- Protecting low voltage distribution and service entrance cables against short-circuit currents.
## **Typical Applications**
## **Catalog Numbers**
- Welder circuits
- **Copper Cable Limiter — 600 Volts**
- Because welder limiters have special characteristics, they are not intended for application on general-use circuits
|**Catalog**|**Cable**|**Catalog**|**Cable**||• Because welder limiters have special characteristics, they|• Because welder limiters have special characteristics, they|
|---|---|---|---|---|---|---|
|**Number**|**Size**|**Number**|**Size**||are not intended for application on general-use circuits||
|**Tubular Terminals**|||||||
|KCY<br>#4<br>KCF<br>4/0<br>KCZ<br>#3<br>KCH<br>250 MCM<br>**Catalog Numbers**<br>**Catalog**<br>**Fuse Holder**<br>**Nominal**<br>~~a~~|||||||
|KCA<br>KCB<br>KCC|#2<br>#1<br>1/0|KCJ1, 2<br>KCM1, 2, 3, KCM-B1<br>KCV|350 MCM<br>500 MCM<br>600 MCM||**Numbers**<br>**Type**<br>68300<br>Class H|**Amp Rating**<br>300|
|KCD1, 2|2/0|KCR1, 2|750 MCM||68600<br>Class H|600|
|KCE|3/0|KCS|1000 MCM||||
||||||64200<br>Class J|200|
|**Tubular Terminal and Offset Bolt**<br>KQV<br>#12||**Tubular Terminal and Offset Bolt-Type Terminal**<br>KDD1|2/0||64300<br>Class J|300|
|KQV|#12|KDD1|2/0|
|---|---|---|---|
|KQT|#10|KDE|3/0|
|KFZ|#8|KDF|4/0|
|KIG|#6|KDH|250 MCM|
|KDY|#4|KDJ1, 2|350 MCM|
|KDA|#2|KDM1,2,3|500 MCM|
|KDB|#1|KDU|600 MCM|
|KDC|1/0|KDR1,2|750 MCM|
|**Compression Connector Rod and Tubular Terminals**||||
|KEX|4/0|KQO|350 MCM|
|KFH-A|250 MCM|KDT2|500 MCM|
|***Center Bolt-Type Terminal and Off**|**Type Terminal and Off-Set Bolt-Type Terminal**|||
|KPF|4/0|KDP1|500 MCM|
|KFT1|250 MCM|KFM1|750 MCM|
|KEW1|350 MCM|||
1*Copper or aluminum cable; sizes of all other limiters pertain to copper only. KFM copper only.UL Listed (File E90818).
- 2Available with shrink tube “_V” suffix.
3Available with molded rubber boots. Add “–B” to end of part number.
## **Accessories**
Boots can be purchased separately. For KCM BOOT-KCM For KDM BOOT-KDM
Installation tools can be purchased separately from Thomas and Betts
- Crimp Tool: TBM-14M • Die: 15506 KDM/15515 KDR
**Recommended Fuse Blocks For 68000 & 64000 Series limiters**
• See page 72
**Data Sheet: 1045**
**Data Sheet: 1042**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**74**
**Low Voltage Supplementary Fuses**
## **13⁄32˝ x 1 1⁄2˝ Fast-acting Fuses**
## **BAF**
## **Specifications**
**Class:** Supplemental **Description:** Fast-acting supplementary fuse.
**Dimensions:**[13] ⁄32˝ x 1[1] ⁄2 ˝ (10.3 x 38.1mm).
## **Ratings:**
Volts — 250Vac (or less) Amps —[2] ⁄10-30A
- IR — 10kA @ 125Vac ([2] ⁄10-30A)
- 35A ([2] ⁄10-1A @ 250Vac)
- 100A (1[1] ⁄2-3A @ 250Vac)
- 200A (4-10A @ 250Vac)
- 750A (12A- 15A @ 250Vac)
- 200A (20-30A @ 250Vac)
**Agency Information:** CE, Std. 248-14, UL 0-15/250V, Guide JDYX, File E19180 CSA Certified, 0-15/250V, Class 1422-01, File 53787.
## **Features and Benefits**
- Low cost supplemental protection of 125V and 250V non-inductive circuits.
- Upgrade with LP-CC product to reduce SKU investment and minimize potential arc-flash hazards. (and minimize potential for misapplying fuse.)
## **Typical Applications**
- General Purpose Circuits
- Lighting Circuit Protection
- Meter Circuits
## **Catalog Numbers (Amps)**
|BAF-1⁄4|BAF-2-1⁄2|BAF-9|
|---|---|---|
|BAF-1⁄2|BAF-3|BAF-10|
|BAF-6⁄10|BAF-4|BAF-12|
|BAF-8⁄10|BAF-5|BAF-15|
|BAF-1|BAF-6|BAF-20|
|BAF-1-1⁄2|BAF-6-1⁄4|BAF-25|
|BAF-1-8⁄10|BAF-7|BAF-30|
|BAF-2|BAF-8||
## **KTK**
**Specifications Class:** Supplemental **Description:** Fastacting supplementary fuse.
**Dimensions:**[13] ⁄32˝ x 1[1] ⁄2˝ (10.3 x 38.1mm).
**Ratings:**
Volts — 600Vac (or less)
Amps —[1] ⁄10-30A
IR — 100kA RMS Sym. (UL) **Agency Information:** CE, Std. 248-14, UL Listed, Guide JDYX, File E19180.
## **Features and Benefits**
- Low cost supplemental protection of 600V or less non-inductive circuits.
- Upgrade with LP-CC product to reduce SKU investment and minimize potential arc flash hazards.
## **Typical Applications**
- Control Circuits
- Lighting Circuit Protection
- Meter Circuits
## **Catalog Numbers (Amps)**
600Vac - UL Listed and CSA
|KTK-1⁄10<br>KTK-1⁄8<br>KTK-2⁄10|KTK-3⁄4<br>KTK-1<br>KTK-1-1⁄4|KTK-4<br>KTK-5<br>KTK-6|KTK-12<br>KTK-15<br>KTK-20|KTK-50*|
|---|---|---|---|---|
|KTK-1⁄4<br>KTK-3⁄10|KTK-1-1⁄2<br>KTK-2|KTK-7<br>KTK-7-1⁄2|KTK-25<br>KTK-30||
|KTK-4⁄10|KTK-2-1⁄2|KTK-8|KTK-35*||
|KTK-1⁄2|KTK-3|KTK-9|KTK-40*||
|KTK-6⁄10|KTK-3-1⁄2|KTK-10|KTK-45*||
*Rated for no more than 24A continuous.
## **KLM**
## **Specifications**
**Class:** Supplemental **Description:** Full range, fast-acting, DC midget fuse.
**Dimensions:**[13] ⁄32˝ x 1[1] ⁄2˝ (10.3 X 38.1mm).
**Ratings:**
Volts — 600Vac/dc
Amps —[1] ⁄10-30A
IR — 100kA AC
— 50kA DC
**Agency Information:** CE, UL Listed: STD. 248-14,
(FILE #E19180), CSA Certified, C22.2 NO. 248. 14 (CLASS #1422-01, FILE #53787).
## **Features and Benefits**
- Full range, fast-acting, 600Vac/dc midget fuse.
- Minimum interrupting rating or 200% rated current at 600Vdc.
## **Typical Applications**
- DC Control Circuits Requiring Fast-Acting Fuses.
- Solar power energy sources - use the Bussmann PVM fuse for DC ratings up to 600Vdc.
## **Catalog Numbers (Amps) - KLM**
|KLM-1⁄10|KLM-3⁄4|KLM-5|KLM-20|
|---|---|---|---|
|KLM-1⁄8|KLM-1|KLM-6|KLM-25|
|KLM-2⁄10|KLM-1-1⁄2|KLM-8|KLM-30|
|KLM-1⁄4|KLM-2|KLM-10||
|KLM-3⁄10|KLM-3|KLM-12||
|KLM-1⁄2|KLM-4|KLM-15||
*All have interrupting rating of 10,000A at 125V.
For superior electrical protection, Bussmann recommends upgrading BAF and fuse applications to Low-Peak LP-CC fuses See page 23.
**Data Sheet: 2011 (0-30)**
For superior electrical protection, Bussmann recommends upgrading KTK fuse applications to Low-Peak LP-CC fuses See page 23.
**Data Sheet: 1011**
**Data Sheet: 2020**
**Recommended fuse blocks/fuse holders for[13] ⁄32” x 1[1] ⁄2” fuses**
• See page 72
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**75**
**Low Voltage Supplementary Fuses**
## **13⁄32˝ x 1 1⁄2˝ Time-delay Fuses**
## **FNM**
## **Specifications**
**Class:** Supplemental **Description:** Time-delay supplementary fuse.
**Dimensions:**[13] ⁄32˝ x 1[1] ⁄2˝ (10.3 x 38.1mm).
## **Ratings:**
Volts — 250Vac (or less) Amps —[1] ⁄10-30A
- IR — 35A ([1] ⁄10-1A @ 250Vac) — 100A (1[1] ⁄8-3[1] ⁄2A @ 250Vac)
- 200A (4-10A @ 250Vac)
- 10kA ([1] ⁄10-10A @ 125Vac) — 10kA (12-30A @ 250Vac)
**Agency Information:** CE, Std. 248-14, UL Listed, 0-30/250Vac; File E19180, Guide JDYX, CSA Certified, 1-30/250Vac; Class 1422-01, File 53787.
## **Features and Benefits**
- Low cost supplemental protection of 125V and 250V inductive circuits.
## **FNQ**
## **Specifications**
**Class:** Supplemental **Description:** Time-delay supplementary fuse. **Dimensions:**[13] ⁄32˝ x 1[1] ⁄2˝ (10.3 x 38.1mm).
## **Ratings:**
Volts — 500Vac (or less)
Amps —[1] ⁄10-30A
IR — 10kA RMS Sym.
**Agency Information:** CE, Std. 248-14, UL Listed, Guide JDYX, File E19180 CSA Certified, Class 1422-01, File 53787.
## **Features and Benefits**
- Low cost supplemental protection of transformers and relays at 500V or less.
## **Typical Applications**
- Control Transformer 480V Primary Protection
- Lighting Circuit Protection
- Meter Circuits
## **Catalog Numbers (Amps)**
## **Typical Applications**
- General Purpose Circuits
- Lighting Circuit Protection
- Meter Circuits
- Upgrading to LP-CC product will reduce SKU investment and minimize potential for misapplying fuse
|FNQ-1⁄10|FNQ-4⁄10|FNQ-1-1⁄2|FNQ-3-1⁄2|FNQ-7|FNQ-20|
|---|---|---|---|---|---|
|FNQ-1⁄8|FNQ-1⁄2|FNQ-1-6⁄10|FNQ-4|FNQ-8|FNQ-25|
|FNQ-15⁄100|FNQ-6⁄10|FNQ-2|FNQ-4-1⁄2|FNQ-9|FNQ-30|
|FNQ-3⁄16|FNQ-8⁄10|FNQ-2-1⁄4|FNQ-5|FNQ-10||
|FNQ-2⁄10|FNQ-1|FNQ-2-1⁄2|FNQ-5-6⁄10|FNQ-12||
|FNQ-1⁄4|FNQ-1-1⁄8|FNQ-3|FNQ-6|FNQ-14||
|FNQ-3⁄10|FNQ-1-1⁄4|FNQ-3-2⁄10|FNQ-6-1⁄4|FNQ-15||
## **Catalog Numbers (Amps)**
|**Catalog Numbers (Amps)g Numbers (Amps) Numbers (Amps)**|**Catalog Numbers (Amps)g Numbers (Amps) Numbers (Amps)**|**Catalog Numbers (Amps)g Numbers (Amps) Numbers (Amps)(Amps)Amps)ps)s))**||||
|---|---|---|---|---|---|
|FNM-1⁄10|FNM-1⁄2|FNM-1-1⁄2|FNM-3|FNM-6|FNM-15|
|FNM-1⁄8|FNM-6⁄10|FNM-1-6⁄10|FNM-3-2⁄10|FNM-6-1⁄4|FNM-20|
|FNM-15⁄100|FNM-3⁄4|FNM-1-8⁄10|FNM-3-1⁄2|FNM-7|FNM-25|
|FNM-2⁄10|FNM-1|FNM-2|FNM-4|FNM-8|FNM-30|
|FNM-1⁄4|FNM-1-1⁄8|FNM-2-1⁄4|FNM-4-1⁄2|FNM-9||
|FNM-3⁄10|FNM-1-1⁄4|FNM-2-1⁄2|FNM-5|FNM-10||
|FNM-4⁄10|FNM-1-4⁄10|FNM-2-8⁄10|FNM-5-6⁄10|FNM-12||
For superior electrical protection, Bussmann recommends upgrading FNM and FNQ fuse applications to Low-Peak LP-CC fuses See page 23.
## **Recommended fuse blocks and fuse holders for**
## **13⁄32˝ x 1 1⁄2˝ fuses**
- See page 72
For superior electrical protection, Bussmann recommends upgrading FNM and FNQ fuse applications to Low-Peak LP-CC fuses See page 23.
## **Recommended fuse blocks and fuse holders for**
## **13⁄32˝ x 1 1⁄2˝ fuses**
- See page 72
**Data Sheet: 2028**
**Data Sheet: 1012**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**76**
**Low Voltage Supplementary Fuses**
## **13⁄32˝ x 1 3⁄8˝ Fast-acting Fuses**
## **BBS**
## **Specifications**
**Class:** Supplemental **Description:** Fast-acting supplementary fuse. **Dimensions:**[13] ⁄32˝ x 1[3] ⁄8˝
(10.3 x 34.9mm). **Construction:** Fiber cartridge.
## **Ratings:**
Volts — 600Vac ([1] ⁄10-5A) — 250Vac (6 - 10A)
— 48Vac (12-30A)
Amps —[1] ⁄10-30A IR — 10kA RMS Sym.
**Agency Information:** CE, Std. 248-14, UL Listed, 0-5A/600V, Guide JDYX, File E19180, CSA Certified, 0-5A/600V, Class 1422-01, File 53787.
## **Features and Benefits**
- Low cost supplemental protection of non-inductive circuits
- Reduced interchangeability with other supplemental fuses minimizes misapplication
## **Typical Applications**
- Control Circuits
- Lighting Ballasts
- Meter Circuits
## **Catalog Numbers (Amps)**
|BBS-1⁄10|BBS-8⁄10|BBS-4|BBS-15|
|---|---|---|---|
|BBS-2⁄10|BBS-1|BBS-5|BBS-20|
|BBS-1⁄4|BBS-1-1⁄2|BBS-6|BBS-25|
|BBS-4⁄10|BBS-1-6⁄10|BBS-7|BBS-30|
|BBS-1⁄2|BBS-1-8⁄10|BBS-8||
|BBS-6⁄10|BBS-2|BBS-10||
|BBS-3⁄4|BBS-3|BBS-12||
## **Recommended fuse blocks/fuse holders for[13] ⁄32˝ x 1[3] ⁄8˝ fuses**
• Page 73
**Data Sheet: 2010 (0-30A)**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**77**
**Low Voltage Supplementary Fuses**
## **Pin Indication Fuses**
## **GBA**
## **GLD**
## **Specifications**
**Class:** Supplemental **Description:** Fast-acting, pin indication fuse.
**Dimensions:**[1] ⁄4˝ x 1[1] ⁄4˝ (6.6 x 31.7mm) 3AG.
## **Ratings:**
Volts — See Agency Info below Amps —[1] ⁄2-15A
IR — See Agency Info below **Agency Information:** CE, Std. 24814, UL Listed, 0-5A/125Vac, 10,000 AIC, Guide JDYX, File E19180, UL Recognized, 6A/125Vac, 1000AIC 8-15A/50Vac/dc, 300 AIC Guide JDYX2, File E19180, CSA Certified: 0-5A/125Vac, 10,000 AIC Class 1422-01, File 53787.
## **Features and Benefits**
- Type GBA has a “red” pin indicator providing visual identification of failed circuits, resulting in faster troubleshooting (reduced circuit downtime).
- Type GLD has a plated pin to activate transmitting a electrical signal to indicate the location of opened circuits, resulting in reduced downtime.
## **Typical Applications**
- Control Circuits
- Electronic Circuits
## **GLD Catalog Numbers (Amps)**
|GLD-1⁄2|GLD-2|GLD-6|
|---|---|---|
|GLD-3⁄4|GLD-3|GLD-10|
|GLD-1|GLD-4|GLD-12|
|GLD-1-1⁄2|GLD-5|GLD-15|
## **GBA Catalog Numbers (Amps)**
|GBA-1⁄2|GBA-2|GBA-8|
|---|---|---|
|GBA-3⁄4|GBA-3|GBA-10|
|GBA-1|GBA-4|GBA-15|
|GBA-1-1⁄2|GBA-5||
**Recommended fuse blocks/fuse holders for[1] ⁄4˝ x 1[1] ⁄4˝ indicating fuses**
- Page 73
**Data Sheet: 2012**
## **MIC & MIN**
## **Specifications**
**Class:** Supplemental **Description:** Fastacting, pin indication fuse.
## **Dimensions:**
13⁄32˝ x 1 1⁄2˝ (10.3 x 38.1mm) 5AG.
## **Ratings:**
Volts — 250Vac (1-15A)
— 32Vac (20-30A)
Amps — 1-30A IR — 35A (1A @250Vac)
— 100A (2-3A @250Vac) — 200A (5-10A @250Vac) — 750A (15A @250Vac)
- 10kA (20-30A @32V)
- 35A (1A @250Vac)
**Agency Information:** CE, Std. 248-14, MIC—0-15A UL Listed, 125Vac/10kA IR Guide JDYX, File E19180, MIN—1-5A CSA Certified, Class 1422-01, File 53787.
## **Features and Benefits**
• Type MIN has a “red” pin indicator providing visual identification of failed circuits, resulting in faster trouble shooting (reduced circuit downtime). • Type MIC has silver-plated pin transmitting an electrical signal indicating location of a failed circuit, resulting in faster troubleshooting (reduced circuit downtime).
## **Typical Applications**
- Control Circuits
- PLC Circuits
- Electronic Circuits
## **MIC Catalog Numbers (Amps)**
|MIC-1|MIC-5|MIC-20|
|---|---|---|
|MIC-2|MIC-10|MIC-25|
|MIC-3|MIC-15|MIC-30|
## **MIN Catalog Numbers (Amps)**
|MIN-1|MIN-5|MIN-20|
|---|---|---|
|MIN-2|MIN-10|MIN-25|
|MIN-3|MIN-15|MIN-30|
**Recommended signal block for**
**13⁄32˝ x 1 1⁄2˝ indicating fuses**
- Page 73
**Data Sheet: 2047**
## **FNA**
## **Specifications**
**Class:** Supplemental **Description:** Time-delay, pin indication fuse. **Dimensions:**[13] ⁄32˝ x 1[1] ⁄2˝ (10.3 x 38.1mm).
## **Ratings:**
Volts — 250Vac ([1] ⁄10-[8] ⁄10A)
- 125Vac (1-15A)
- 32Vac (20-30A)
Amps —[1] ⁄10-30A
IR — 35A ([1] ⁄10-[8] ⁄10A @ 250Vac)
- 10kA ([1] ⁄10-15A @ 125Vac)
- 1kA (20-30A @ 32V)
**Agency Information:** CE, Std. 24814, UL Listed[1] ⁄10-[8] ⁄10A, IR 35A@ 250V, IR 10kA@ 125V , 1-15A, IR 10kA@ 125V, Guide JDYX, File 19180, CSA Certified, 0-[8] ⁄10A/250V, 1-10A/125V, Class 1422-01, File 53787.
## **Features and Benefits**
- FNA has a pin indicator providing visual identification of failed circuits, resulting in reduced circuit downtime.
- Time-delay response allows close sizing on control transformers and relays
## **Typical Applications**
- Control Circuits
- Electronic Circuits
## **Catalog Numbers (Amps)**
|FNA-1⁄10<br>FNA-1⁄8|FNA-8⁄10<br>FNA-1|FNA-2-1⁄2<br>FNA-2-8⁄10|FNA-6-1⁄4<br>FNA-7|
|---|---|---|---|
|FNA-15⁄100|FNA-1-1⁄8|FNA-3|FNA-8|
|FNA-2⁄10|FNA-1-1⁄4|FNA-3-2⁄10|FNA-9|
|FNA-1⁄4|FNA-1-4⁄10|FNA-3-1⁄2|FNA-10|
|FNA-3⁄10|FNA-1-1⁄2|FNA-4|FNA-12*|
|FNA-4⁄10|FNA-1-6⁄10|FNA-4-1⁄2|FNA-15*|
|FNA-1⁄2<br>FNA-6⁄10|FNA-1-8⁄10<br>FNA-2|FNA-5<br>FNA-5-6⁄10|FNA-20*<br>FNA-25*|
|FNA-3⁄4|FNA-2-1⁄4|FNA-6|FNA-30|
*12-30A versions are dual-tube construction
## **Recommended signal block for**
**13⁄32˝ x 1 1⁄2˝ indicating fuses**
- Page 73 **Data Sheet: 2029**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**78**
**Low Voltage Supplementary Fuses**
## **Pin Indication Fuse and Actuator, and Limiters**
## **ANN & ANL Limiters**
## **Specifications**
**Description:** Circuit limiters. **ANN:** Very fast-acting limiter. **ANL:** Non-time delay limiter. **Dimensions:**[7] ⁄8˝ x 3[3] ⁄16˝ (22.2 x 81.0mm).
**Ratings:**
## **ANN:**
Volts — 125Vac — 80Vdc Amps — 10-800A
IR — 2500A @ 125Vac — 2700A @ 80Vdc
## **ANL:**
Volts — 80Vdc Amps — 35-750A IR — 2700A @ 80Vdc
## **Agency Information:**
**ANN:** 35-400A @ 125Vac, IR=2500A and 500A @ 80Vdc, IR=2700A: UL Recognized Guide JFHR2, File E56412; CSA Certified Class 1422-30, File 53787, CE for 35-400A.
**ANL:** UL Recognized, CSA Certified, 35-750A @ 80Vdc, IR = 2700A, Guide JFHR2, File E56412, Class 1422-30, File 53787, SAE J1171.
## **Features and Benefits**
- Fast-acting circuit protection (ANN).
- • Time-delay sizing for inductive circuits (ANL).
- Window shows limiter status.
**Typical Applications**
- Fork lifts, Marine, Aviation
## **ANN Catalog Numbers (Amps)**
|ANN-10|ANN-90|ANN-225|ANN-400|
|---|---|---|---|
|ANN-35<br>ANN-40|ANN-100<br>ANN-125|ANN-250<br>ANN-275|ANN-500<br>ANN-600|
|ANN-50|ANN-150|ANN-300|ANN-700|
|ANN-60|ANN-175|ANN-325|ANN-800|
|ANN-80|ANN-200|ANN-350||
## **ANL Catalog Numbers (Amps)**
|ANL-35<br>ANL-40<br>ANL-50<br>ANL-60|ANL-125<br>ANL-130<br>ANL-150<br>ANL-175|ANL-250<br>ANL-275<br>ANL-300<br>ANL-325|ANL-500<br>ANL-600<br>ANL-675<br>ANL-750|
|---|---|---|---|
|ANL-80<br>ANL-100|ANL-200<br>ANL-225|ANL-350<br>ANL-400||
## **MIS**
## **KAZ**
## **Specifications**
**Specifications Description:** Non-fuse actuator.
**Class:** Supplemental **Description:** Non timedelay pin indication fuse. **Dimensions:**[13] ⁄32˝ x 2˝
**Dimensions:**[13] ⁄32˝ x 2˝
(10.3 x 50.8mm).
**Ratings:**
(10.3 x 50.8mm).
Volts — 600Vac
## **Ratings:**
Amps — N/A
Volts — 600Vac Amps — 1-12A IR — 200kA
IR — 200kA
**Agency Information:** CE, UL Listed, Guide JDVS, File E58836.
## **Features and Benefits**
• Type MIS has a pin indicator providing visual identification of failed circuits, resulting in faster troubleshooting (reduced circuit downtime).
## **Features and Benefits**
- Bussmann signal blocks 2778, 2837
or 2838 with KAZ actua-
tors mounted in parallel with fuses having a rating of 50A or larger to provide blown fuse dropout of shunt-trip fused switches.
• Type MIS can be used in circuits rated 600V or less.
• Type MIS has an interrupting rating of 200kA.
- Type KAZ can be used in circuits rated 600V or less.
- Type KAZ has an interrupting rating of 200kA.
## **Typical Applications**
- 480V Control Circuits
- • PLC Circuits
## **Typical Applications**
- Large, Shunt-Trip Fused Switches
## **Catalog Numbers (Amps)**
- Fuse Protected Circuits Rated 50A or Larger With Shunt-Trip Devices.
|MIS-1<br>MIS-2|MIS-4<br>MIS-5|MIS-10<br>MIS-12|
|---|---|---|
|MIS-3<br>**Test Specifications**<br>**Fuse**<br>All|MIS-8<br>**Test Specifications**<br>**Load**<br>110%|**Opening Time**<br>0 4 hrs. (min.)|
|1-5A|150%|0 6 min. (max.)|
|6-12A|150%|12 min. (max.)|
## **Catalog Number: KAZ**
## **Recommended signal block for 13⁄32˝ x 2˝ indicating fuses**
## **Recommended signal block for 13⁄32˝ x 2˝ indicating fuses** • Page 73
- Page 73
## **Data Sheet: 2021**
## **4164 & 4164-FR Limiter Blocks**
## **Specifications**
**Description:** Limiter fuse blocks for ANL & ANN.
## **Ratings:**
- 4164 furnished with nylon inserted locknuts
Volts — 125Vac
- 4164-FR furnished with standard hex nuts **Dimensions:** Length: 3.38˝
- 80Vdc
- 32Vdc (Self Certified)
Width: 0.95˝ Height: 1.62˝ Studs center to center: 2.43˝
Amps — 10-800A **Poles:** 1 - stud terminal
## **Data Sheets: 2023 (ANN), 2024 (ANL)**
**Data Sheet: 2133**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**79**
**Low Voltage Supplementary Fuses**
## **In-line Size Rejecting Fuses and Fuse Holders**
## **GLQ**
## **Specifications**
**Class:** Supplemental **Description:** Fast-acting, size-rejecting in-line fuse. **Construction:** Glass tube.
## **Ratings:**
Volts — 300Vac (or less) Amps — 1-10A IR — 10kA
**Agency Information:** CE, Std. 248-14, UL Listed (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787).
## **Features and Benefits**
- In-Line, fast-acting circuit protection.
- Rejection feature prevents overfusing.
## **Typical Applications**
- In-line Lighting Ballast Protection
## **GMQ**
## **Specifications**
**Class:** Supplemental **Description:** Time-delay, size-rejecting in-line fuse. **Construction:** Ceramic tube.
## **Ratings:**
Volts — 300Vac (or less) Amps —[1] ⁄2-6[1] ⁄4A
IR — 10kA
**Agency Information:** CE, Std. 248-14, UL Listed (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787)
## **Features and Benefits**
- In-line, fast-acting circuit protection.
- • Rejection feature prevents overfusing.
## **Typical Applications**
- In-Line Lighting Ballast Protection
## **Catalog Numbers (Amps) and Rejection Holders**
|**1, 2**|**1, 2**|
|---|---|
|**Fuse**<br>**Holder1, 2**|**Fuse**<br>**Holder1, 2**|
|GLQ-1<br>HLQ-1-6⁄10|GLQ-3<br>HLQ-3-2⁄10|
|GLQ-1-1⁄2<br>HLQ-1-6⁄10|GLQ-4<br>HLQ-5|
|GLQ-1-6⁄10<br>HLQ-1-6⁄10|GLQ-5<br>HLQ-5|
|GLQ-2<br>HLQ-3-2⁄10|GLQ-9<br>HLQ-10|
|GLQ-2-1⁄2<br>HLQ-3 -2⁄10|GLQ-10<br>HLQ-10|
- 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10A, 300Vac.
- 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030” to 0.042”.
- Do not put tension on line (rear) terminal of fuse holder.
## **Catalog Numbers (Amps) and Rejection Holders**
|**Fuse**<br>**Holders1, 2**|**Fuse**<br>**Holders3, 4**|
|---|---|
|GMQ-1⁄2<br>HLQ-1⁄2|GMQ-2-1⁄2<br>HLQ-3-2⁄10|
|GMQ-6⁄10<br>HLQ-1-6⁄10|GMQ-3<br>HLQ-3-2⁄10|
|GMQ-8⁄10<br>HLQ-1-6⁄10|GMQ-3-2⁄10<br>HLQ-3-2⁄10|
|GMQ-1<br>HLQ-1-6⁄10|GMQ-4<br>HLQ-5|
|GMQ-1-1⁄4<br>HLQ-1-6⁄10|GMQ-6<br>HLQ-8|
|GMQ-1-6⁄10<br>HLQ-1-6⁄10|GMQ-6-1⁄4|
|GMQ-2<br>HLQ-3-2⁄10||
- 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10A, 300Vac.
- 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030” to 0.042”
- Do not put tension on line (rear) terminal of fuse holder.
**Data Sheet: 2033**
**Data Sheet: 2030**
**3 HLQ Fuse Holders for both GLQ & GMQ fuses.**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**80**
**Low Voltage Supplementary Fuses**
## **In-line Non-rejecting Fuses and Fuse Holders**
## **GLR**
## **Specifications**
**Class:** Supplemental **Description:** Fast-acting, non-rejection, in-line fuse. **Construction:** Glass tube.
## **Ratings:**
Volts — 300Vac (or less) Amps —[3] ⁄16-15A
IR — 10kA
**Agency Information:** CE, Std. 248-14, UL Listed, 0-15A/300Vac (Guide JDYX, File E19180), CSA Certified, 0-10A/300V (Class 1422-01, File 53787).
## **Features and Benefits**
- In-line, fast-acting circuit protection.
## **Typical Applications**
- In-Line Lighting Ballast Protection
## **Catalog Numbers (Amps) and Non-Rejection Holders**
|**1, 2***|**1, 2***|
|---|---|
|**Fuse**<br>**Holder1, 2***|**Fuse**<br>**Holder1, 2***|
|GLR-1⁄2<br>HLR|GLR-6<br>HLR|
|GLR-1<br>HLR|GLR-7<br>HLR|
|GLR-1-1⁄2<br>HLR|GLR-8<br>HLR|
|GLR-1-6⁄10<br>HLR|GLR-9<br>HLR|
|GLR-2<br>HLR|GLR-10<br>HLR|
|GLR-3<br>HLR|GLR-12<br>HLR|
|GLR-4<br>HLR|GLR-15<br>HLR-2A|
|GLR-5<br>HLR||
- 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac.
- 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030˝ to 0.042˝.
- **For two leads (one each for line and loadside) order HLR-2A, 15A, 300V**
- An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes _WITHOUT_ leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
- Do not put tension on line (rear) terminal of fuse holder.
## **GMF**
## **GRF**
**Specifications Class:** Supplemental **Description:** Time-delay, non-rejection, in-line fuse. **Construction:** Glass tube.
## **Ratings:**
Volts — 300Vac (or less) Amps —[3] ⁄10-10A
IR — 10kA
**Agency Information:** CE, Std. 248-14 0-10A, UL Listed (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787).
## **Features and Benefits**
- In-line, time-delay circuits protection.
## **Typical Applications**
- In-Line Lighting Ballast Protection
## **Catalog Numbers (-Amps) and Non-Rejection Holders**
|**Fuse**<br>**Holder1, 2***|**Fuse**<br>**Holder1, 2***|
|---|---|
|GMF-3⁄10<br>HLR|GMF-3<br>HLR|
|GMF-1⁄2<br>HLR|GMF-3-2⁄10<br>HLR|
|GMF-6⁄10<br>HLR|GMF-4<br>HLR|
|GMF-8⁄10<br>HLR|GMF-5<br>HLR|
|GMF-1<br>HLR|GMF-6-1⁄4<br>HLR|
|GMF-1-1⁄4<br>HLR|GMF-10<br>HLR|
|GMF-1-6⁄10<br>HLR|GRF-7<br>HLR|
|GMF-2<br>HLR|GRF-8<br>HLR|
|GMF-2-1⁄2<br>HLR|GRF-10<br>HLR|
|GMF-2-8⁄10<br>HLR||
- 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac.
- 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030˝ to 0.042˝.
## ***For two leads order HLR-2A, 15A, 300V**
- An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes _WITHOUT_ leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
- Do not put tension on line (rear) terminal of fuse holder.
**Data Sheet: 2032**
## **Data Sheet: 2031**
## — **HLR-2A Fuse Holder HLR Fuse HolderFuse Holder**
## **HLR Fuse HolderFuse Holder**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**81**
**Low Voltage Supplementary Fuses**
## **Automotive Blade-type Fuses & Holders**
**==> picture [59 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
ATC Fuse<br>**----- End of picture text -----**<br>
**==> picture [122 x 80] intentionally omitted <==**
**----- Start of picture text -----**<br>
Available<br>With<br>S Indication &<br>(Actual Size)<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Fast-acting blade fuse.
**Construction:** Colored plastic housing with zinc fuse element. **Ratings:**
Volts — 32Vdc Amps — 1-40A IR — 1000A
**Agency Information:** UL Recognized, (3-40A) (Guide JFHR2, File E56412), SAE Standard J1284.
## **Features and Benefits**
- Color coded plastic housing for easy identification of fuse ratings
- **Typical Applications**
- Automotive
## **Catalog Numbers (Amps)**
|**Non-Indicating**<br>ATC-1<br>ATC-2<br>ATC-3<br>ATC-4<br>ATC-5<br>ATC-7-1/2|***Indicating**<br>ATC-3ID<br>ATC-5ID<br>ATC-7-1/2ID|**Color**<br>Black<br>Gray<br>Violet<br>Pink<br>Tan<br>Brown|
|---|---|---|
|ATC-10|ATC-10ID|Red|
|ATC-15<br>ATC-20<br>ATC-25<br>ATC-30<br>ATC-35<br>ATC-40|ATC-15ID<br>ATC-20ID<br>ATC-25ID<br>ATC-30ID<br>ATC-35ID<br>ATC-40ID|Blue<br>Yellow<br>Clear<br>Green<br>Blue-Green<br>Orange|
**==> picture [61 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
ATM Fuse<br>**----- End of picture text -----**<br>
**HHC, HHD, HHF, HHG & ATC-FHID**
_**Available With**_ ~* ¢ e _**Indication**_ / wT ATM ATM-LP (Actual Size)
**==> picture [34 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
LED Indicator<br>**----- End of picture text -----**<br>
## **Specifications**
_**easy**_ **ID™ LED Indicating Holder**
**Description:** Fast-acting blade fuse. **Construction:** Colored plastic housing with zinc fuse element.
## **Specifications**
**Description:** In-line fuse holders for ATC[™] Blade-Type fuses.
## **Ratings:**
Volts — 32Vdc Amps — 2-30A IR — 1000A
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 32Vdc
## **Features and Benefits**
Amps:— 80% continuous of fuse rating. See Catalog Numbers table for individual fuses sizes.
- Color coded plastic housing for easy identification of fuse ratings
## **Typical Applications**
- Automotive
## **Catalog Numbers**
|Catalog|Fuse Holder|Fuse|Electrical||
|---|---|---|---|---|
|Numbers<br>HHC<br>HHD<br>HHF<br>HHG<br>ATC-FHID|Description<br>Yellow<br>Black<br>Black w/ cover<br>Black w/ cover<br>Indicating Holder<br>Black w/ cover|Amps <br>1-20<br>1-30<br>1-20<br>1-30<br>1-20|Connection<br>#16 black leadwire<br>#12yellow leadwire<br>#16yellow leadwire<br>#12yellow leadwire<br>#16 black leadwire|**Catalog Numbers(Amps)**<br>**Non-Indicating**<br>***Indicating**<br>**Low-Profile**<br>ATM-2<br>ATM-3<br>ATM-3ID<br>ATM4<br>~~===~~|
**Non-Indicating *Indicating Low-Profile Color** ATM-2 Gray ATM-3 ATM-3ID Violet ATM-4 Pink ATM-5 ATM-5ID ATM-5LP Tan ATM-7-[1] /2 ATM-7-[1] /2ID ATM-7-[1] /2LP Brown ATM-10 ATM-10ID ATM-10LP Red ATM-15 ATM-15ID ATM-15LP Blue ATM-20 ATM-20ID ATM-20LP Yellow ATM-25 ATM-25ID ATM-25LP Clear ATM-30 ATM-30ID ATM-30LP Green ~~===~~ *Call Bussmann Customer Satisfaction for ordering information.
A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended.
## **HHC & HHD Dimensions - in**
~~0.78"~~ 0.364"
~~0.91" 0.5" ht~~ 0.38" 0.30" ~~F~~ 0.25" ~~——~~ 4.0"[+] 0.25" 1.125" 4.0"[+] 0.25" ~~a~~
*Call Bussmann Customer Satisfaction for ordering information.
**Data Sheet: 2048**
**Data Sheet: 2009**
**Data Sheet: 2107**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**82**
**Low Voltage Supplementary Fuses** Ba
## **Automotive Blade-type Fuses & Holders**
**==> picture [143 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
HHL, HHM & ATM-FHID<br>**----- End of picture text -----**<br>
**==> picture [34 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
LED Indicator<br>**----- End of picture text -----**<br>
_**easy**_ **ID™ LED Indicating Holder**
## **Specifications**
**Description:** In-line fuse holders for ATM Fuses.
## **Ratings:**
Volts: — 32Vdc Amps: — 80% continuous of fuse rating. See Catalog Numbers table for individual fuses sizes.
**Catalog Numbers Catalog Fuse Holder Fuse Electrical Numbers Description Amps Connection** HHL Black w/ cover 2-20 #16 black leadwire, 4˝ length stripped to[1] /4˝ HHM Black w/ cover 2-30 #12 red leadwire, 4˝ length stripped to[1] /4˝ ATM-FHID[Indicating Holder] 2-20 #16 black leadwire ~~——~~ Black w/ cover A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended.
**HHL & HHM Dimensions - in**
**==> picture [149 x 45] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.56"<br>.59"<br>.25" .25"<br>4.75" 4.75" .41"<br>**----- End of picture text -----**<br>
**==> picture [29 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HHX<br>**----- End of picture text -----**<br>
**==> picture [153 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
MAX Maxi–Fuse<br>Available<br>With<br>Indication<br>(Actual Size)<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Fast-acting blade fuse. **Construction:** Colored plastic housing with zinc fuse element.
## **Specifications**
**Description:** In-line fuse holders for MAXI Fuses.
## **Ratings:**
## **Ratings:**
Volts — 32Vdc
Volts: — 32Vdc
Amps — 20-80A (non-indicating) 20-100A (indicating) IR — 1000A
Amps: — 80% continuous of fuse rating. See Catalog Numbers table for individual fuses sizes.
## **Features and Benefits**
**==> picture [341 x 188] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|•|Color coded plastic housing for easy|Catalog Numbers|
|identification of fuse ratings|CatalogNumbers|DescriptionFuse Holder|AmpsFuse|ConnectionElectrical|
|Typical Applications|HHX|Black w/ cover|20-60|#6 red leadwire,|
|•|Automotive|5˝ with blunt ends|
|A fuse must be properly and fully inserted into the holder to|
|Catalog Numbers (Amps)|provide a solid connection. Poor or improper insertion of thefuse can result in failure of the fuse and holder, thus notfuse can result in failure of the fuse and holder, thus not|
|Non-Indicating|*Indicating|Color|protecting the device for which it was intended.|
|MAX-20|MAX-20ID|Yellow|—|Dimensions - in|
|MAX-25|Gray|3.35"|
|MAX-30|MAX-30ID|Green|
|MAX-35|Brown|
|6.70|"|6.70|"|
|MAX-40|MAX-40ID|Orange|
|MAX-50|MAX-50ID|Red|
|MAX-60|MAX-60ID|Blue|.265" DIA. HOLE|
|MAX-70|MAX-70ID|Tan|
|MAX-80|MAX-80ID|Clear|
|MAX-100ID|Purple|
**----- End of picture text -----**<br>
A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of thefuse can result in failure of the fuse and holder, thus notfuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended.
**==> picture [128 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.35"<br>6.70 " 6.70 "<br>1.37"<br>.265" DIA. HOLE<br>**----- End of picture text -----**<br>
*Call Bussmann Customer Satisfaction for ordering information.
**Recommended in-line fuse holder for blade type fuses** • Page 83
**Data Sheet: 2049**
**Data Sheet: 2129**
**Data Sheet: 2128**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**83**
**Low Voltage Supplementary Fuses**
## **Automotive Blade-type PCB Fuseclips**
## **ATM Fuses**
## **1A5778 Series**
Dimensional Data
## **ATC Fuses (0 to 20 Amps) 1A5600 Series**
Dimensional Data
**==> picture [106 x 203] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.90<br>0.075<br>3.96<br>0.156<br>4.98<br>0.196<br>11.18<br>0.440<br>1.57<br>0.062<br>3.18<br>0.125<br>1.57<br>0.062<br>3.66 2.18<br>0.144 0.086<br>3.66 4.47 3.66<br>0.144 0.176 0.144<br>0.065 ± 0.0021.65 ± 0.05 DIA. HOLE<br>(TYP-4)<br>MOUNTING LAYOUT FOR 2 CLIPS<br>**----- End of picture text -----**<br>
MATERIAL: BRASS, NICKEL PLATED, THICK0.0120.30
## **Data Sheet: 2131**
## **1A5779 Series**
**==> picture [167 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
14.68<br>0.578 1.24<br>0.049<br>4.75<br>0.187<br>BASE<br>FUSECLIPS<br>8.64<br>0.340<br>3.18<br>0.125<br>2.54<br>0.100<br>1.45<br>0.057<br>3.66 1.57<br>0.144 0.062<br>**----- End of picture text -----**<br>
**==> picture [244 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
(7.49mm).295" Catalog Clip<br>Number Mat.* Finish<br>.330" Satin<br>(8.38mm) 1A5600 Cart.<br>Brass Finish Tin<br>.053"<br>(1.35mm)<br>(3.81mm).150" (5.08mm).200" (2.03 0.08" ± ±0.25mm) 0.01"<br>.090"<br>(2.29mm)<br>**----- End of picture text -----**<br>
**==> picture [71 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data Sheet: 2131<br>**----- End of picture text -----**<br>
## **1A5780 Series**
**==> picture [72 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensional Data<br>**----- End of picture text -----**<br>
**==> picture [167 x 215] intentionally omitted <==**
**----- Start of picture text -----**<br>
19.30<br>0.760<br>4.45<br>0.175 3.18<br>0.125<br>BASE<br>6.88<br>0.271 FUSECLIPS<br>6.35<br>0.250<br>11.10<br>0.437<br>1.27<br>0.050<br>5.08 4.06 5.08<br>0.200 0.160 0.200<br>0.100 ± 0.0022.54 ± 0.05 DIA. HOLE<br>(TYP-4)<br>MOUNTING LAYOUT<br>**----- End of picture text -----**<br>
**==> picture [127 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
SPECIFICATIONS<br>FUSECLIPS . . . . . . . . BRASS, NICKEL PLATED<br>BASE MATERIAL . . . . . GLASS FILLED NYLON,<br>UL RATED 94V-0<br>CURRENT RATING . . . . . 15 AMPS<br>VOLTAGE RATING . . . . . 500V AC<br>TEMPERATURE RATING . . -50ºC TO 145ºC -58ºF 292ºF<br>**----- End of picture text -----**<br>
*Spg. Br. - Spring Bronze; BeCu - Beryllium Copper; Cart. Brass - Cartridge Brass
**==> picture [218 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.66 4.47 3.66<br>0.144 0.176 0.144 SPECIFICATIONS<br>FUSECLIPS . . . . . . . . BRASS, NICKEL PLATED<br>BASE MATERIAL . . . . . GLASS FILLED NYLON,<br>UL RATED 94V-0<br>0.065 ± 0.0021.65 ± 0.05 DIA. HOLE CURRENT RATING . . . . . 15 AMPS<br>(TYP-4) VOLTAGE RATING . . . . . 500V AC<br>MOUNTING LAYOUT TEMPERATURE RATING . . -50ºC-58ºF TO 145ºC292ºF<br>**----- End of picture text -----**<br>
***For RoHS compliant version add “-R” option code suffix to part number.
**Data Sheet: 2131**
**Data Sheet: 2131**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**84**
## **Electronic - PC Board and Small Dimension Fuses & Accessories**
## **Section Contents**
|**Section Contents**|**Section Contents**|
|---|---|
|**Page**||
|5 x 15mm ferrule fuses . . . . . . . . . . . . . . . . . . . . . . 86|5 x 15mm ferrule fuses . . . . . . . . . . . . . . . . . . . . . . 86|
|5 x 20mm European (IEC) ferrule fuses . . . . . . . . 87-88||
|5 x 20mm North American (UL) ferrule fuses . . . . .|89|
|1⁄4˝ Dia. x5⁄8˝ to 1˝ length ferrule fuses . . . . . . . . . . .|90|
|1⁄4˝ Dia. x 11⁄4˝ length fast-acting ferrule fuses . . . . . .|91|
|1⁄4˝ Dia. x 11⁄4˝ length time-delay ferrule fuses . . . . . .|92|
|PCB mount fuse holders . . . . . . . . . . . . . . . . . . . 93-94||
|PCB fuseclips for 5mm dia. fuses . . . . . . . . . . . . . .|95|
|PCB fuseclips for1⁄4˝ dia. fuses . . . . . . . . . . . . . . . 96-97||
|PCB fuseclips for1⁄4˝,9⁄32˝,13⁄32˝ &9⁄16˝ fuses . . . . . . . .|98|
Scan this tag to get the latest product information for Electronic Fuses and Accessories.
**85**
**Electronic — PCB & Small Dimension Fuses**
## **5 x 15mm Ferrule Fuses**
**C515 (axial leads) C518 (axial leads) C517 (axial leads) C519 C520 Specifications Description:** Fast-acting **Specifications Specifications** fuse. **Description: Description: Construction:** Glass tube. Time-delay fuse. Fast-acting fuse. **Dimensions: Dimensions: Ratings:** Volts — 350Vac* 5 x 15mm 5 x 15mm (0.197” X 0.591”). (0.197” X 0.591”). — 32Vdc (Self Certified) **Construction: Construction:** Glass tube. Glass tube. Amps — 3A **Ratings:** a, **Ratings:** IR — 100A @ 350Vac Volts — 125Vac (3.5Volts — 250Vac — 100A @ 7A) — 32Vdc (Self 250Vac — 250Vac Certified) — 10kA @ (125mA-3A) e¢ Amps — 100mA-5A fF 125Vac ~« — 32Vdc (Self Certified) IR — 35A (100mA-750mA @ *350Vac/100A IR is UL Recognized **Agency Information:** CE, UL Listing Amps — 125mA-7A 250Vac) File E19180, Guide JDYX, CSA IR — 25A (350mA @ 600Vac) — 10kA (100mA-5A @ 125Vac) Certification File 53787, Class — 35A (125mA-1A @ 250Vac) — 100A (1.5-3.5A @ 250Vac) 1422-01, UL Recognized, File E19180, Guide JDYX2.
- 10kA (100mA-5A @ 125Vac) — 100A (1.5-3.5A @ 250Vac) — 200A (4-5A @ 250Vac)
- 35A (125mA-1A @ 250Vac) — 100A (1.25-3A @ 250Vac) — 400A (3.5-7A @ 125Vac)
- Small footprint saves space in equipment.
**Agency Information:** CE,
UL Recognized File E19180, Guide JDYX2CSA Certification File 53787, Class 1422-01.
- 10kA (125mA-3A @ 125Vac)
- Fast-acting for maximum component protection.
**Agency Information:** CE, UL Listed File E19180, Guide JDYX 125mA-250mA and 375mA-3A, UL Recognized, File E19180, Guide JDYX2, 350mA and 3.5A-7A, CSA Certification File 53787, Class 1422-01, 125mA-250mA and 375mA-3A.
- 350Vac rating for 277V ballast circuit protection.
## **Features and Benefits**
- Small footprint saves space in equipment.
## **Typical Applications**
- Fast-acting for maximum component protection.
- • Available in ferrule and axial leaded configurations
- Electronic Circuits
- Printed Circuit Boards
- Electronic Ballast Protection
## **Features and Benefits**
**Catalog Number (Amps) With Axial Leads** C517-3-R
- Time-delay for closer sizing on inductive circuits.
## **Typical Applications**
- Electronic Circuits
## **Typical Application**
- Printed Circuit Boards
- Electronic Circuits
- Printed Circuit Boards
## **Catalog Numbers (Amps)**
## **With Axial Leads**
## **Catalog Numbers (Amps)**
## **With Axial Leads**
|C515-125-R|C515-800-R|C515-2.5-R|
|---|---|---|
|C515-250-R|C515-1-R|C515-3-R|
|C515-350-R|C515-1.25-R|C515-3.5-R|
|C515-375-R|C515-1.5-R|C515-4-R|
|C515-500-R|C515-1.6-R|C515-5-R|
|C515-600-R|C515-2-R|C515-6-R|
|C515-750-R|C515-2.25-R|C515-7-R|
|**Without Axial Leads**|**Without Axial Leads**||
|C519-125-R|C519-750-R|C519-2.25-R|
|C519-250-R|C519-1-R|C519-2.5-R|
|C519-350-R|C519-1.25-R|C519-3-R|
|C519-375-R|C519-1.5-R|C519-3.5-R|
|C519-500-R|C519-1.6-R|C519-4-R|
|C519-600-R|C519-2-R|C519-5-R|
**Data Sheet: 2006 (C515) & 2007 (C519)**
|C518-100-R|C518-750-R|C518-4-R|
|---|---|---|
|C518-125-R|C518-2-R|C518-5-R|
|C518-250-R|C518-2.5-R||
|C518-375-R|C518-3-R||
|C518-500-R|C518-3.5-R||
|**Without Axial Leads**|**Without Axial Leads**||
|C520-100-R|C520-750-R|C520-3.5-R|
|C520-125-R|C520-1.5-R|C520-4-R|
|C520-250-R|C520-2-R|C520-5-R|
|C520-375-R|C520-2.5-R||
|C520-500-R|C520-3-R||
**Data Sheet: 2026 (C518) & 2027 (C520)**
**Data Sheet: 2025**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**86**
**Electronic — PCB & Small Dimension Fuses** cei
## **5 x 20mm European (IEC) Ferrule Fuses**
## **S500-V (GDB-V)* (axial leads) S500 (GDB)***
**Specifications Description:** Fastacting, low-breaking capacity fuse.
## **Construction:**
Glass tube, nickelplated brass endcaps (silver-plated endcaps, 32-125mA).
@>
## **Ratings:**
Volts — 250Vac (or less)
— 32Vdc (Self Certified)
Amps — 32mA-10A
IR — See catalog table
**Agency Information:** CE, cURus, SEMKO, VDE, BSI, IMQ, CCC. See data sheet for complete agency information. Not all approvals apply to all ratings.
## **Features and Benefits**
- Fast-acting for maximum protection, conforms to IEC 60127-2 (160mA-10A).
## **Typical Applications**
- Electronic Circuits
## **Catalog Numbers (Amps)**
|**Catalog**<br>**Numbers**<br>S500-32-R<br>S500-40-R|**IR**<br>**(Amps)**<br>35<br>35|**I2t**<br>0.000047<br>0.00011|**Max Voltage**<br>**Drop (mV)**<br>3200<br>2500|
|---|---|---|---|
|S500-50-R|35|0.00020|2400|
|S500-63-R|35|0.00057|2000|
|S500-80-R<br>S500-100-R<br>S500-125-R<br>S500-160-R<br>S500-200-R<br>S500-250-R<br>S500-315-R<br>S500-400-R<br>S500-500-R<br>S500-630-R<br>S500-800-R|35<br>35<br>35<br>35<br>35<br>35<br>35<br>35<br>35<br>35<br>35|0.0012<br>0.003<br>0.005<br>0.008<br>0.016<br>0.028<br>0.058<br>0.018<br>0.018<br>0.035<br>0.067|1200<br>1100<br>1000<br>2000<br>1700<br>1400<br>1300<br>1100<br>220<br>220<br>190|
|S500-1-R|35|0.60|200|
|S500-1.25-R|35|0.84|200|
|S500-1.6-R|35|1.6|190|
|S500-2-R<br>S500-2.5-R<br>S500-3.15-R<br>S500-4-R<br>S500-5-R|35<br>35<br>35<br>40<br>50|4.2<br>6.1<br>13<br>22<br>42|150<br>150<br>130<br>130<br>120|
|S500-6.3-R|63|69|120|
|S500-8-R|80|-|120|
|S500-10-R|100|—-|120|
## **Options**
Axial leads, put “V” in P/N, *When ordering GDB version, do not add “-R” suffix to part number.
**Data Sheet: 2052 (S500), 2015 (GDB)**
**S501-V (GDA-V)* (axial leads) S501 (GDA)***
**Specifications Description:** Fastacting, high-breaking capacity fuse.
**Construction:**
Ceramic tube, nickel-plated brass endcaps (silverplated endcaps 50mA-400mA). **Ratings:** Volts — 250Vac (or less) >
Volts — 250Vac (or less) — 32Vdc (Self Certified) Amps — 50mA-10A**
IR — 1500A @ 250Vac
**Agency Information:** CE, cURus, SEMKO, VDE, IMQ, CCC, CSA, BSI.
See data sheet for complete agency information. Not all approvals apply to all ratings.
**Features and Benefits**
- Fast-acting for maximum protection.
- High break capacity for use in higher fault energy electronic circuitry.
- Conforming to IEC standards.
## **Typical Applications**
- Electronic Circuits
|**Catalog Numbers (Amps)**<br>**Catalog**<br>**Numbers**|**Catalog Numbers (Amps)**<br>**Typical Voltage**<br>**I2t**<br>**Drop (mV)**|**Catalog Numbers (Amps)**<br>**Typical Voltage**<br>**I2t**<br>**Drop (mV)**|
|---|---|---|
|S501-50-R|0.0017|9000|
|S501-63-R|0.0005|3300|
|S501-80-R|0.0011|2600|
|S501-100-R|0.0018|2300|
|S501-125-R|0.0037|1900|
|S501-160-R|0.008|1600|
|S501-200-R|0.020|1350|
|S501-250-R|0.027|1300|
|S501-315-R|0.010|1400|
|S501-400-R|0.018|1200|
|S501-500-R<br>S501-630-R<br>S501-800-R<br>S501-1-R|0.038<br>0.064<br>0.097<br>0.146|1050<br>1200<br>490<br>330|
|S501-1.25-R|0.313|297|
|S501-1.6-R|0.748|239|
|S501-2-R|2.0|205|
|S501-2.5-R|3.9|190|
|S501-3.15-R<br>S501-4-R|8.1<br>14|160<br>160|
|S501-5-R<br>S501-6.3-R|25<br>48|155<br>150|
|S501-8-R|N/A|N/A|
|S501-10-R|N/A|N/A|
## **Options**
Axial leads, put “V” in P/N.
*When ordering GDA version, do not add “-R” suffix to part number.
**GDA is not available above 6.3A.
**Data Sheet: 2051 (S501), 2014 (GDA)**
## **S505-V (axial leads)**
## **S505**
**Specifications Description:** Timedelay, high-breaking capacity fuse.
**Construction:**
Ceramic tube, silverplated brass endcaps.
## **Ratings:**
Volts — 250Vac (or less) — 32Vdc (Self Certified) — 500mA-12A @
Amps — 500mA-12A
IR — 1500A @ 250Vac
**Agency Information:** UL, CSA, SEMKO, VDE, BSI, IMQ, PSE/JET, CCC, EK, FIMKO.
See data sheet for complete agency information. Not all approvals apply to all ratings.
## **Features and Benefits**
- Time-delay performance ideal for inductive circuits.
- Conforming to IEC standards.
## **Typical Applications**
- Electronic Circuits
## **Catalog Numbers (Amps)**
|**Catalog**<br>**Numbers**|**Typical**<br>**I2t**|**Max Voltage**<br>**Drop (mV)**|
|---|---|---|
|S505-500-R|0.188*|295|
|S505-800-R|0.632*|189|
|S505-1-R|1.28|152.5|
|S505-1.25-R|2.22|150|
|S505-1.6-R|6.78|125|
|S505-2-R|9.60|118.5|
|S505-2.5-R|16.60|115|
|S505-3.15-R|36.60|102.5|
|S505-4-R|38.45*|86.5|
|S505-5-R|71.30*|77.5|
|S505-6.3-R|197|75|
|S505-8-R|311|75|
|S505-10-R|397|72|
|S505-12-R|713.7*|77|
*The typical I[2] t value was measured at 10 times of rated current under DC.
## **Options**
Axial leads, put “V” in P/N.
**Data Sheet: 2037**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**87**
**Electronic — PCB & Small Dimension Fuses**
## **5 x 20mm European (IEC) Ferrule Fuses**
## **S505H (S505H-V)***
## **(axial leads)**
**Specifications Description:** Timedelay, high-breaking capacity fuse.
## **Construction:**
Ceramic tube, nickelplated brass endcaps.
## **Ratings:**
Volts — 600Vac/400Vdc
- 500mA-5A
- 6.3A-10A
- 500Vac/400Vdc
Amps — 500mm-10A
IR — 35A @ 250Vac
**Agency Information:** cURus, CCC, CQC, TUV, PSE/JET.
See data sheet for complete agency information. Not all approvals apply to all ratings.
## **Features and Benefits**
- Time-delay, high breaking capacity
- Conforming to IEC standards
## **Typical Applications**
- Power supplies - adapters
- Desktops/notebooks
## **Catalog Numbers (Amps)**
|**Catalog**<br>**Numbers**|**Typical**<br>**I2t (A2s)1**|**Max Voltage**<br>**Drop (mV)3**|
|---|---|---|
|S505H-500-R|0.188|295|
|S505H-800-R|0.632|189|
|S505H-1-R|1.28|153|
|S505H-1.25-R|2.22|150|
|S505H-1.6-R|6.78|125|
|S505H-2-R|11.44|128|
|S505H-2.5-R|24.23|126|
|S505H-3.15-R|43.55|121|
|S505H-4-R|38.45|90|
|S505H-5-R|71.3|89|
|S505H-6.3-R|111.4|80|
|S505H-8-R|228.2|76|
|S505H-10-R|349.5|72|
1. Typical Pre-Arc I[2] t: Measured at 10In DC.
2. - Breaking Capacity of 250VAC/1500A is tested by all agency approvals, test condition is 250Vac, PF: 0.7-0.8.
- Breaking Capacity of Max. voltage is tested by UL, PF:1.
- Breaking Capacity Test of DC is tested by UL under Capacitor Bank 4800mF (for 400V, 1500A) 2400mF (for 400V, 500A).
3. Typical Voltage Drop: Voltage drop is measured under ambient 20°C with rated current.
## **Options**
Axial leads, put “V” in P/N.
**S506-V (GDC-V)* (axial leads) S506 (GDC)***
**Specifications Description:** Timedelay, low-breaking he ' capacity fuse. **Construction:** Glass tube, nickel-plated brass endcaps. **Ratings:** Volts — 250Vac (or less) — 32Vdc (Self Certified) Amps — 32mA-15A** IR — 35A @ 250Vac ros **Agency Information:** UR, CSA, cURus, SEMKO, VDE, BSI, IMQ, PSE/JET, CCC.
See data sheet for complete agency information. Not all approvals apply to all ratings.
## **Features and Benefits**
- Time-delay compatibility for inductive circuits
- Conforming to IEC standards
## **Typical Applications**
- Electronic Circuits
|**Catalog Numbers (Amps)**|**Catalog Numbers (Amps)**||
|---|---|---|
|**Catalog**<br>**Numbers**<br>S506-32-R|**Typical**<br>**I2t**<br>0.0051|**Max Voltage**<br>**Drop (mV)**<br>1050|
|S506-40-R|0.0072|920|
|S506-50-R|0.0095|800|
|S506-63-R|0.021|760|
|S506-80-R|0.038|580|
|S506-100-R|0.045|490|
|S506-125-R|0.063|390|
|S506-160-R|0.093|320|
|S506-200-R|0.114|340|
|S506-250-R|0.265|270|
|S506-315-R|0.621|250|
|S506-400-R|0.872|210|
|S506-500-R|0.827|140|
|S506-630-R|1.33|150|
|S506-800-R|2.78|75|
|S506-1-R|6.45|87.5|
|S506-1.25-R<br>S506-1.6-R<br>S506-2-R|10.05<br>21.7<br>31.6|86<br>82<br>77|
|S506-2.5-R<br>S506-3.15-R<br>S506-4-R|59.4<br>96.4<br>71.8|72.5<br>68.5<br>67|
|S506-5-R|142.5|60.5|
|S506-6.3-R|237.6|54|
|S506-8-R|255.8|55|
|S506-10-R|450|54|
|S506-12.5-R|1019.5|45|
|S506-15-R|1091.7|65.5|
## **Options**
Axial leads, put “V” in P/N.
- *When ordering GDC version, do not add
- “-R” suffix to part number.
- **GDC series is not available above 6.3A.
**Data Sheet: 2016 (GDC), 4332 (S506)**
**Data Sheet: 4406**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**88**
**Electronic — PCB & Small Dimension Fuses** grt
## **5 x 20mm North American (UL) Ferrule Fuses**
**GMA-V (axial leads) GMC-V (axial leads) GMD-V (axial leads) GMA GMC GMC-10A GMD GMD Specifications Specifications Specifications Description: Description:** Medium **Description:** TimeFast-acting fuse. time-delay fuse. delay fuse. **Dimensions: Dimensions:** 5 x 20mm **Dimensions:** 5 x 20mm (0.197” x 0.788”). 5 x 20mm (0.197” x 0.788”). **Construction:** Glass (0.197” x 0.788”). **Construction:** tube, nickel-plated brass **Construction:** Glass tube, endcaps. Glass tube, nickelo ~~on~~ nickel-plated brass **Ratings:** plated brass endcaps. Volts — 250Vac (63mAendcaps. **Ratings:** 3.15A) **Ratings:** Volts — 250Vac (63mA-2.5A) > — 125Vac (3.5-10A) — Volts — 250Vac ys — 125Vac (3.15-15A) — 32Vdc (Self Certified)
- 32Vdc (Self Certified)
- 32Vdc (Self Certified)
Amps — 125mA-4A
Amps — 63mA-10A
- IR — 10kA (125mA-3A @ 125Vac, p.f. = 0.7-0.8)
Amps — 63mA-15A
- IR — 35A (63mA- 1A @ 250Vac, p.f. = 0.7-0.8)
- IR — 35A (63mA- 1A @ 250Vac, p.f. = 0.7-0.8)
- 10kA (4A @ 125Vac, p.f. = 1.0)
- — 35A (125mA-1A @ 250Vac, p.f. = 0.7-0.8)
- 10kA (63mA-6A @ 125Vac, p.f. = 0.7-0.8)
- 10kA (63mA-6A @ 125Vac, p.f. = 0.7-0.8)
- 100A (1.25-3.15A @ 250Vac, p.f. = 0.7-0.8)
- 100A (1.25-2.5A @ 250Vac, p.f. = 0.7-0.8)
- 100A (1.2A-3.A @ 250Vac, p.f. = 0.7-0.8)
- 200A (6.3-10A @ 125Vac, p.f. = 1.0)
- 200A (7-8A @ 125Vac, p.f. = 1.0)
- 200A (4A @ 250Vac, p.f. = 1.0)
- 150A (10-15A @ 125Vac, p.f. = 1.0)
**Agency Information:** CE, Std. 248-14, UL Listed Guide JDYX, File E19180, 0-6.3A, UL Recognized, Guide JDYX2, File E19180, 7-8A, CSA Certified, Class 1422-01, File 53787, 0-6.3A.
**Agency Information:** CE, UL Listed Guide JDYX, File E19180, 125mA-3A, UL Recognized, Guide JDYX2, File E19180, 4A, CSA Certified, Class 1422-01, File 53787, 0-4A, PSE/JET. File 1641-31003-1001, 1.2A-4A.
**Agency Information:** CE, Std. 248-14 UL Listed Guide JDYX, File E19180, 0-6A, UL Recognized, Guide JDYX2, File E19180, 7-15A, CSA Certified, Class 1422-01,File 53787, 0-6.
## **Features and Benefits**
- Conforming to UL standards.
## **Features and Benefits**
## **Typical Applications**
## **Features and Benefits**
- Fast-acting for maximum protection.
- Electronic Circuits
• Time-delay compatibility for inductive circuits.
## **Typical Applications**
- Conforming to UL standards.
## **Catalog Numbers (Amps)**
- Electronic Circuits
## **With Axial Leads**
## **Typical Applications**
|GMC-V-63-R<br>GMC-V-80-R|GMC-V-500-R<br>GMC-V-600-R|GMC-V-2.5<br>GMC-V-3.15|||**Typical Applications**<br>• Electronic Circuits|**Typical Applications**<br>Electronic Circuits||
|---|---|---|---|---|---|---|---|
|GMC-V-100-R|GMC-V-630-R|GMC-V-3.5||||||
|GMC-V-125-R<br>GMC-V-150-R|GMC-V-750-R<br>GMC-V-800-R|GMC-V-4<br>GMC-V-5|||**Catalog Numbers (Amps)**<br>**With Axial Leads**|||
|GMC-V-200-R|GMC-V-1-R|GMC-V-6|||GMD-V-125-R|GMD-V-500-R|GMD-V-1.5-R|
|GMC-V-250-R|GMC-V-1.25-R|GMC-V-6.3|||GMD-V-150-R|GMD-V-600-R|GMD-V-1.6-R|
|GMC-V-300-R|GMC-V-1.5-R|GMC-V-7|||GMD-V-200-R|GMD-V-630-R|GMD-V-2-R|
|GMC-V-315-R|GMC-V-1.6-R|GMC-V-8|||GMD-V-250-R|GMD-V-750-R|GMD-V-2.5-R|
|GMC-V-400-R|GMC-V-2-R|GMC-V-10|||GMD-V-300-R|GMD-V-800-R|GMD-V-3-R|
|**Without Axial Leads**|||||GMD-V-315-R|GMD-V-1-R|GMD-V-4-R|
|GMC-63mA|GMC-500-R|GMC-2.5-R|||GMD-V-375-R|GMD-V-1.2-R||
|GMC-80mA|GMC-600-R|GMC-3.15-R|||GMD-V-400-R|GMD-V-1.25-R||
|GMC-100mA|GMC-630-R|GMC-3.5-R|||**Without Axial Leads**|**Without Axial Leads**||
|GMC-125mA|GMC-750-R|GMC-4-R|||GMD-125-R|GMD-500-R|GMD-1.5-R|
|GMC-150mA|GMC-800-R|GMC-5-R|||GMD-150-R|GMD-600-R|GMD-1.6-R|
|GMC-200mA|GMC-1-R|GMC-6-R|||GMD-200-R|GMD-630-R|GMD-2-R|
|GMC-250mA|GMC-1.25-R|GMC-6.3-R|||GMD-250-R|GMD-750-R|GMD-2.5-R|
|GMC-300mA|GMC-1.5-R|GMC-7-R|||GMD-300-R|GMD-800-R|GMD-3-R|
|GMC-315mA|GMC-1.6-R|GMC-8-R|||GMD-315-R|GMD-1-R|GMD-4-R|
|GMC-400mA<br>GMC-2-R<br>**Data Sheet: 4395**||GMC-10-R|||GMD-375-R<br>GMD-1.2-R<br>GMD-400-R<br>GMD-1.25-R<br>**Data Sheet:2019**|||
## **Catalog Numbers (Amps)**
## **With Axial Leads**
|GMA-V-63-R|GMA-V-800-R|GMA-V-4-R|
|---|---|---|
|GMA-V-100-R|GMA-V-1-R|GMA-V-5-R|
|GMA-V-125-R|GMA-V-1.25-R|GMA-V-6-R|
|GMA-V-200-R|GMA-V-1.5-R|GMA-V-7-R|
|GMA-V-250-R|GMA-V-1.6-R|GMA-V-8-R|
|GMA-V-300-R|GMA-V-2-R|GMA-V-10-R|
|GMA-V-500-R|GMA-V-2.5-R|GMA-V-15-R|
|GMA-V-600-R|GMA-V-3.15-R||
|GMA-V-750-R|GMA-V-3.5-R||
|**Without Axial Leads**|||
|GMA-63-R|GMA-800-R|GMA-4-R|
|GMA-100-R|GMA-1-R|GMA-5-R|
|GMA-125-R|GMA-1.25-R|GMA-6-R|
|GMA-200-R|GMA-1.5-R|GMA-7-R|
|GMA-250-R|GMA-1.6-R|GMA-8-R|
|GMA-300-R|GMA-2-R|GMA-10-R|
|GMA-500-R|GMA-2.5-R|GMA-15-R|
|GMA-600-R|GMA-3.15-R||
|GMA-750-R|GMA-3.5-R||
|**Data Sheet: 2017**|||
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**89**
**Electronic — PCB & Small Dimension Fuses**
## **1 5 ⁄4˝ Dia. x ⁄8˝ to 1˝ Length Ferrule Fuses**
## **AGA**
## **AGW**
## **AGX**
**Specifications Description:** Fast-acting fuse.
**Specifications Specifications Specifications Description:** Fast-acting **Description:** Fast-acting **Description:** Fast-acting fuse. fuse. fuse. **Dimensions: Dimensions:**[1] ⁄4˝ x[7] ⁄8˝ **Dimensions:**[1] ⁄4˝ x 1˝ 5 4˝ x ˝ x 5 ⁄8˝ (6.4 x 22.2mm). (6.4 x 25.4mm). (6.4 x 15.9mm). **Construction:** Glass **Construction:** Glass tube. **Construction:** Glass tube. tube. **Ratings: Ratings: Ratings:** Volts — 250Vac ([1] ⁄16-20A) Volts — 125Vac (or less) ie Volts — 32Vac — 125Vac (25-30A) — 32Vdc (Self Certified) — 32Vdc (Self Certified) — 32Vdc ([1] ⁄16-30A) Amps — 1-30A Amps — 1-30A Amps —[1] ⁄16-30A IR — 10kA (1-1[[1]] ⁄2A @ 125Vac)2A @ 125Vac)A @ 125Vac) **Features and Benefits** IR — 35A ([1] ⁄16-1A @ 250Vac)
## **Dimensions:**
1⁄4˝ x ˝ x 5
(6.4 x 15.9mm).
**Construction:** Glass tube.
**Ratings:**
- Amps — 1-30A
IR — 10kA (1-1[[1]] ⁄2A @ 125Vac)2A @ 125Vac)A @ 125Vac) — 200A (2-5A @ 125Vac) — 1000A (6-30A @ 32Vac)
## **Features and Benefits**
- 10kA ([1] ⁄16-10A @ 125Vac)
- Fast-acting for maximum protection.
- 200A (15-20A @ 125Vac)
## **Typical Applications**
**Agency Information:** CE, Std. 24814, UL File E19180, UL Listed, Guide JDYX 0-3[1] ⁄2A UL Recognized, Guide JDYX2 12-30A.
- 100A (25-30A @ 125Vac)
- Electronic Circuits
- 1000A (8-30A @ 32Vac)
## **Catalog Numbers (Amps)**
**Agency Information:** cULus: AGX 0-10A (Guide JDYX, File E 19180 and
|AGW-1<br>AGW-1-1⁄2|AGW-4<br>AGW-5|AGW-15<br>AGW-20|
|---|---|---|
|AGW-2|AGW-6|AGW-25|
|AGW-2-1⁄2|AGW-7-1⁄2|AGW-30|
|AGW-3|AGW-10||
## **Features and Benefits**
Guide JDYX7, File E19180), UL Recognized Card: AGX 15-30A (Guide JDYX2, File E19180), CSA Component Acceptance Card : AGX 15-30A (Class No. 1422-01, File 53787)
- Fast-acting for maximum protection.
- Size rejects insertion of other fuse types.
## **Typical Applications**
- Electronic Circuits
## **Features and Benefits**
- Size rejects insertion of other fuse types.
## **Catalog Numbers (Amps)**
|AGA-1|AGA-5|AGA-15|
|---|---|---|
|AGA-1-1⁄2|AGA-6|AGA-20|
|AGA-2|AGA-7|AGA-25|
|AGA-2-1⁄2|AGA-7-1⁄2|AGA-30|
|AGA-3|AGA-10||
## **Typical Applications**
• Electronic Circuits
## **Catalog Numbers (Amps)**
|AGX-1⁄4|AGX-1-1⁄2|AGX-8|
|---|---|---|
|AGX-3⁄10|AGX-2|AGX-10|
|AGX-3⁄8|AGX-2-1⁄2|AGX-15|
|AGX-4⁄10|AGX-3|AGX-20|
|AGX-1⁄2|AGX-4|AGX-25|
|AGX-3⁄4|AGX-5|AGX-30|
|AGX-1|AGX-6||
|AGX-1-1⁄4|AGX-7||
**==> picture [246 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data Sheet: 2040 Data Sheet: 2041<br>**----- End of picture text -----**<br>
**Data Sheet: 2039**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**90**
**Electronic — PCB & Small Dimension Fuses** Baa
## **1 1 ⁄4˝ Dia. x 1 ⁄4˝ Length Fast-acting Ferrule Fuses**
## **AGC (AGC-V axial leads)**
**Specifications Description:** Fast-acting fuse. ˝ **Dimensions:**[1] ⁄4˝ x 1[1] ⁄4 (6.4 x 31.7mm).
## **Construction:** Glass
tube with nickel-plated brass endcaps.
## **Ratings:**
Volts — 250Vac ([1] ⁄20-10A) — 32Vac (12-30A) — 32Vdc (Self Certified) @
Amps —[1] ⁄20-30A IR — 35A ([1] ⁄20-1A @ 250Vac) — 100A (1[1] ⁄4-3A @ 250Vac) — 200A (4-10A @ 250Vac)
- 10kA ([1] ⁄20-10A @ 125Vac) — 1000A (12-30A @ 32Vac)
**Agency Information:** CE, UL Listed, Guide JDYX, File E19180, 0-10A UL Recognized, Guide JDYX2, File E19180, 12-30A CSA Certification, Class 1422-01, File 053787,[1] ⁄20-30A.
## **Features and Benefits**
- Original electronic glass tube fuse.
- Fast-acting for maximum protection.
- Wide amp/volt ratings allow versatility of protecting electronic circuits.
## **Typical Applications**
- Electronic Circuits
## **Catalog Numbers (Amps)**
## **With Axial Leads**
|AGC-V-1⁄20-R|AGC-V-1-1⁄4-R|AGC-V-8-R|
|---|---|---|
|AGC-V-1⁄10-R|AGC-V-1-1⁄2-R|AGC-V-9-R|
|AGC-V-1⁄8-R<br>AGC-V-3⁄16-R<br>AGC-V-2⁄10-R<br>AGC-V-1⁄4-R|AGC-V-2-R<br>AGC-V-2-1⁄4-R<br>AGC-V-2-1⁄2-R<br>AGC-V-3-R|AGC-V-10-R<br>AGC-V-12-R<br>AGC-V-14-R<br>AGC-V-15-R|
|AGC-V-3⁄10-R<br>AGC-V-3⁄8-R<br>AGC-V-1⁄2-R<br>AGC-V-3⁄4-R|AGC-V-4-R<br>AGC-V-5-R<br>AGC-V-6-R<br>AGC-V-7-R|AGC-V-20-R<br>AGC-V-25-R<br>AGC-V-30-R|
|AGC-V-1-R|AGC-V-7-1⁄2-R||
|**Without Axial Leads**|**Without Axial Leads**||
|AGC-1⁄20-R|AGC-1-1⁄4-R|AGC-8-R|
|AGC-1⁄10-R|AGC-1-1⁄2-R|AGC-9-R|
|AGC-1⁄8-R|AGC-2-R|AGC-10-R|
|AGC-3⁄16-R|AGC-2-1⁄4-R|AGC-12-R|
|AGC-2⁄10-R|AGC-2-1⁄2-R|AGC-14-R|
|AGC-1⁄4-R|AGC-3-R|AGC-15-R|
|AGC-3⁄10-R|AGC-4-R|AGC-20-R|
|AGC-3⁄8-R|AGC-5-R|AGC-25-R|
|AGC-1⁄2-R|AGC-6-R|AGC-30-R|
|AGC-3⁄4-R|AGC-7-R||
|AGC-1-R|AGC-7-1⁄2-R||
## **ABC (ABC-V axial leads)**
## **GBB (GBB-V axial leads)**
**Specifications Specifications Description:** Fast-acting fuse. **Description:** Very **Dimensions:** fast-acting fuse. 1 1 ⁄4˝ x 1 ⁄4˝ (6.4 x 31.7mm). **Dimensions:** 1 1 ⁄4˝ x 1 ⁄4˝ **Construction:** Ceramic tube (6.4 x 31.7mm). with nickel-plated brass endcaps. **Construction: Ratings:** Ceramic cartridge with Volts — 250Vac/125Vdc ([1] ⁄4-15A, 20-30A)[*] et nickel-plated brass endcaps. — 250Vac (18A) **Ratings:**
- 32Vdc (Self Certified)
Volts — 250Vac/125Vdc
Amps —[1] ⁄4-30A
Amps — 1-30A
IR** — 35A ([1] ⁄4-1A @ 250Vac)
- IR — 200A @ 250Vac
- 100A (1[1] ⁄2-3A @ 250Vac)
- 200A (20-30A @ 125Vac/dc)
- 200A (4-10A @ 250Vac)
- 10,000A (1A -15A @ 125Vac/dc)
- 750A (12-15A @ 250Vac)
- 400A (18-20A @ 250Vac)
## **Agency Information:**
- 10kA ([1] ⁄4-15A @ 125Vac)
CE, Std. 248-14, UL Recognized, 1-30,125Vdc/250Vac, File E56412, Guide JFHR2, CSA Accepted, 1-30, 125Vdc/250Vac, File 53787, Class 1422-30.
- 1kA (18-30A @ 125Vac)
- 10kA ([1] ⁄4-15, 20A @ 125Vdc)
- 400A (25-30A @ 125Vdc)
- 200A (25-30A @ 250Vac)
*CSA approvals for 25A and 30A are at 125Vac – IR 1000A and Vdc – IR 400A (IR 1000A at 75Vdc)
## **Features and Benefits**
• Very fast-acting performance allows protection of highly sensitive electronic circuitry.
**Interrupting ratings measured at 70% – 80% power factor on AC. The interrupting ratings for 18A and 20A were measured at 85%-95% power factor on AC. The interrupting ratings for 25A and 30A were measured at 89% power factor on AC.
**Agency Information:** CE, Std. 248-14 UL Listed, Guide JDYX File E19180, 1 ⁄4-15A; UL Recognized, Guide JDYX2, File E19180, 18-30A; CSA Certification, Class 1422-01 & 1422-30, File 53787, 1 ⁄4-30A.
## **Typical Applications**
- Electronic Circuits
## **Catalog Numbers (Amps)**
|**With Axial Leads**<br>GBB-V-1-R<br>GBB-V-1-1⁄4-R<br>GBB-V-2-R<br>GBB-V-3-R|GBB-V-6-R<br>GBB-V-7-R<br>GBB-V-8-R<br>GBB-V-9-R|GBB-V-15-R<br>GBB-V-20-R<br>GBB-V-25-R<br>GBB-V-30-R|
|---|---|---|
|GBB-V-4-R|GBB-V-10-R||
|GBB-V-5-R<br>GBB-V-12-R<br>**Without Axial Leads**<br>GBB-1-R<br>GBB-6-R||GBB-15-R|
|GBB-1-1⁄4-R|GBB-7-R|GBB-20-R|
|GBB-2-R<br>GBB-3-R|GBB-8-R<br>GBB-9-R|GBB-25-R<br>GBB-30-R|
|GBB-4-R|GBB-10-R||
|GBB-5-R|GBB-12-R||
## **Features and Benefits**
- Ceramic body allows for higher amp/volt rating combinations.
## **Typical Applications**
- Electronic Circuits
## **Catalog Numbers (Amps)**
## **With Axial Leads**
|ABC-V-1⁄4-R|ABC-V-3-R|ABC-V-12-R|
|---|---|---|
|ABC-V-<br>1⁄2-R|ABC-V-4-R|ABC-V-15-R|
|ABC-V-<br>3⁄4-R|ABC-V-5-R|ABC-V-18-R|
|ABC-V-1-R|ABC-V-6-R|ABC-V-20-R|
|ABC-V-1-1⁄2-R|ABC-V-7-R|ABC-V-25-R|
|ABC-V-2-R|ABC-V-8-R|ABC-V-30-R|
|ABC-V-2-1⁄2-R|ABC-V-10-R||
|~~**Without Axial Leads**~~|||
|ABC-1⁄4-R|ABC-3-R|ABC-12-R|
|ABC-1⁄2-R|ABC-4-R|ABC-15-R|
|ABC-3⁄4-R|ABC-5-R|ABC-18-R|
|ABC-1-R|ABC-6-R|ABC-20-R|
|ABC-1-1⁄2-R|ABC-7-R|ABC-25-R|
|ABC-2-R|ABC-8-R|ABC-30-R|
|ABC-2-1⁄2-R|ABC-10-R||
|**Data Sheet: 2000**|**Data Sheet: 2000**||
**Data Sheet: 2013**
**Data Sheet: 2001**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**91**
**Electronic — PCB & Small Dimension Fuses**
## **1 1 ⁄4˝ Dia. x 1 ⁄4˝ Length Time-delay Ferrule Fuses**
**MDL-V (axial leads) MDQ-V (axial leads) MDL MDQ Specifications Specifications Description: Description:** Time-delay fuse. Dual-element, **Dimensions:**[1] ⁄4˝ x 1[1] ⁄4˝ time-delay fuse. ˝ (6.4 x 31.7mm). **Dimensions:**[1] ⁄4˝ x 1[1] ⁄4 **Construction:** Glass (6.4 x 31.7mm). tube with nickel-plated **Construction:** Glass brass endcaps. T tube with nickel-plated oi brass endcaps.
(6.4 x 31.7mm).
## **Construction:** Glass
tube with nickel-plated brass endcaps.
## **Ratings:**
## **Ratings:**
Volts — 250Vac ([1] ⁄16-8A)
Volts — 250Vac ([1] ⁄100-7A) — 32Vac (7[1] ⁄2-15A) — 32Vdc (Self Certified) Amps —[1] ⁄100-15A
- 32Vac (9-30A)
- 32Vdc (Self Certified)
Amps —[1] ⁄16-30A
- IR* — 35A ([1] ⁄16-1A @ 250Vac)
- IR — 35A ([1] ⁄100-1A @ 250Vac)
- 100A (1[1] ⁄4-3A @ 250Vac)
- 100A (1[1] ⁄4-3A @ 250Vac) — 200A (4-7A @ 250Vac)
- 200A (4-8A @ 250Vac)
- 10000A ([1] ⁄16-8A @ 125Vac)
- 1000A (7[1] ⁄2-12A @ 32Vac)
- 1000A (9-30A @ 32Vac)
**Agency Information:** Std. 248-14, UL Listed, File E19180; Guide JDYX,[1] ⁄16-7A CSA Certification, File 47233, Class 1422-01,[1] ⁄16 -7A, UL Recognized, Guide JDYX2, File E19180, 7.1-30A.
*Interrupting ratings were measured at 70% – 80% power factor on AC, and at a time constant described in UL 198L.
**Agency Information:** CE, UL Listed, Guide JDYX, File E19180,[1] ⁄16-8A; CSA Certification Class 1422-01,[1] ⁄16-8A; UL Recognized, Guide JDYX2, File E19180, 9-30A; CSA Component Acceptance, Class 142230, 9-30A.
## **Features and Benefits**
- Dual-element design allows closer sizing to inductive circuits than any other fuses.
## **Features and Benefits**
- Time-delay allows close sizing on inductive circuits.
## **Typical Applications**
- Electronic Relay and Control Circuits
## **Catalog Numbers (Amps)**
## **Typical Applications**
- Electronic Circuits
## **With Axial Leads**
|MDQ-V-1⁄100|MDQ-V-3⁄10|MDQ-V-1-1⁄2|MDQ-V-5|
|---|---|---|---|
|MDQ-V-1⁄32|MDQ-V-3⁄8|MDQ-V-1-6⁄10|MDQ-V-6|
|MDQ-V-1⁄16|MDQ-V-4⁄10|MDQ-V-1-8⁄10|MDQ-V-6-1⁄4|
|MDQ-V-1⁄10|MDQ-V-1⁄2|MDQ-V-2|MDQ-V-7|
|MDQ-V-1⁄8|MDQ-V-6⁄10|MDQ-V-2-1⁄4|MDQ-V-7-1⁄2|
|MDQ-V-15⁄100<br>MDQ-V-175⁄1000|MDQ-V-3⁄4<br>MDQ-V-8⁄10|MDQ-V-2-1⁄2<br>MDQ-V-2-8⁄10|MDQ-V-8<br> MDQ-V-9|
|MDQ-V-3⁄16|MDQ-V-1|MDQ-V-3|MDQ-V-10|
|MDQ-V-2⁄10|MDQ-V-1-2⁄10|MDQ-V-3-2⁄10|MDQ-V-12|
|MDQ-V-1⁄4<br>**Without Axial Leads**<br>MDQ-1⁄100<br>MDQ-1⁄32<br>MDQ-1⁄16<br>MDQ-1⁄10<br>MDQ-1⁄8|MDQ-V-1-1⁄4<br>**Without Axial Leads**<br>MDQ-3⁄10<br>MDQ-3⁄8<br>MDQ-4⁄10<br>MDQ-1⁄2<br>MDQ-6⁄10|MDQ-V-4<br>MDQ-1-1⁄2<br>MDQ-1-6⁄10<br>MDQ-1-8⁄10<br>MDQ-2<br>MDQ-2-1⁄4|MDQ-15<br>MDQ-5<br>MDQ-6<br>MDQ-6-1⁄4<br>MDQ-7<br>MDQ-7-1⁄2|
|MDQ-15⁄100|MDQ-3⁄4|MDQ-2-1⁄2|MDQ-8|
|MDQ-175⁄1000|MDQ-8⁄10|MDQ-2-8⁄10|MDQ-9|
|MDQ-3⁄16|MDQ-1|MDQ-3|MDQ-10|
|MDQ-2⁄10<br>MDQ-1⁄4|MDQ-1-2⁄10<br>MDQ-1-1⁄4|MDQ-3-2⁄10<br>MDQ-4|MDQ-12<br>MDQ-15|
## **Catalog Numbers (Amps)**
## **With Axial Leads**
|MDL-V-1⁄16-R|MDL-V-1-R|MDL-V-7-R|
|---|---|---|
|MDL-V-1⁄10-R|MDL-V-1-1 ⁄4-R|MDL-V-8-R|
|MDL-V-1⁄8-R<br>MDL-V-2⁄10-R|MDL-V-1-1⁄2-R<br>MDL-V-2-R|MDL-V-9-R<br>MDL-V-10-R|
|MDL-V-3⁄16-R|MDL-V-2-1⁄4-R|MDL-V-12-R|
|MDL-V-1⁄4-R|MDL-V-2-1⁄2-R|MDL-V-15-R|
|MDL-V-3⁄10-R|MDL-V-3-R|MDL-V-20-R|
|MDL-V-3⁄8-R|MDL-V-4-R|MDL-V-25*|
|MDL-V-1⁄2-R|MDL-V-5-R|MDL-V-30*|
|MDL-V-3⁄4-R|MDL-V-6-R||
|**Without Axial Leads**|**Without Axial Leads**||
|MDL-1⁄16-R|MDL-1-R|MDL-7-R|
|MDL-1⁄10-R<br>MDL-1⁄8-R|MDL-1-1⁄4-R<br>MDL-1-1⁄2-R|MDL-8-R<br>MDL-9-R|
|MDL-2⁄10-R|MDL-2-R|MDL-10-R|
|MDL-3⁄16-R|MDL-2-1⁄4-R|MDL-12-R|
|MDL-1⁄4-R|MDL-2-1⁄2-R|MDL-15-R|
|MDL-3⁄10-R|MDL-3-R|MDL-20-R|
|MDL-3⁄8-R|MDL-4-R|MDL-25*|
|MDL-1⁄2-R|MDL-5-R|MDL-30*|
*MDL-25 & MDL-30 are not available in RoHS compliant construction.
**Data Sheet: 2044**
## **MDA-V (axial leads) MDA**
## **Specifications**
**Description:** Time-delay fuse. **Dimensions:**[1] ⁄4˝ x 1[1] ⁄4˝ (6.35 x 31.75mm).
**Construction:** Ceramic tube with nickel-plated brass endcaps.
## **Ratings:**
Volts — 250Vac (or less) — 125Vdc (20A- 30A) — 32Vdc (Self Certified) Amps —[1] ⁄4-30A
IR** — 35A ([1] ⁄4-1A @ 250Vac)
- 100A (1[1] ⁄2-2A @ 250Vac)
- 200A (2[1] ⁄2-10A @ 250Vac)
- 750A (12-15A @ 250Vac)
- 1500A (20-30A @ 250Vac)
- 10kA ([1] ⁄4-30A @ 125Vac)
— 10kA (20-30A @ 125Vdc) **Interrupting ratings were measured at 70% – 80% power factor on AC, and at a time constant described in UL 248.
**Agency Information:** CE, Std. 248-14, UL Listed, Guide JDYX, File E19180, 0-20A CSA Certification, Class 1422-01, File 53787, 0-20A. UL Recognized, Guide JDYX2, File E19180, 25-30A, CSA Component Acceptance, Class 1422-30, 25-30A
## **Features and Benefits**
- Ceramic body allows for higher amp/volt rating combinations.
- Inventory consolidation by replacing MDL fuses allows for reduced SKU investment and minimizing potential for misapplying fuse.
## **Typical Applications**
- Electronic Circuits
## **Catalog Numbers (Amps)**
## **With Axial Leads**
|MDA-V-1⁄4-R|MDA-V-3-R|MDA-V-12-R|
|---|---|---|
|MDA-V-1⁄2-R|MDA-V-4-R|MDA-V-15-R|
|MDA-V-3⁄4-R|MDA-V-5-R|MDA-V-20-R|
|MDA-V-1-R|MDA-V-6-R|MDA-V-25-R|
|MDA-V-1-1⁄2-R|MDA-V-7-R|MDA-V-30-R|
|MDA-V-2-R|MDA-V-8-R||
|MDA-V-2-1⁄2-R|MDA-V-10-R||
|**Without Axial Leads**|**Without Axial Leads**||
|MDA-<br>1⁄4-R|MDA-3-R|MDA-12-R|
|MDA-<br>1⁄2-R|MDA-4-R|MDA-15-R|
|MDA-<br>3⁄4-R|MDA-5-R|MDA-20-R|
|MDA-1-R|MDA-6-R|MDA-25A-R|
|MDA-1-<br>1⁄2-R|MDA-7-R|MDA-30A-R|
|MDA-2-R|MDA-8-R||
|MDA-2-<br>1⁄2-R|MDA-10-R||
**Data Sheet: 2002**
**Data Sheet:2004**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**92**
**Electronic — PCB & Small Dimension Fuses** gi
## **PC Board Mount Fuse Holders**
## **HTC-45M**
## **HTC-50M**
**==> picture [56 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HTC-60M<br>**----- End of picture text -----**<br>
## we th =
## **PCB Vertical Mount**
## **PCB Horizontal Mount**
## **PCB Stand-Off Mount**
## **Specifications**
**Description:** PCB vertical mount bayonet cap and fuse holder. **Dimensions:** See Dimensions illustration.
## **Specifications**
## **Specifications**
**Description:** PCB horizontal mount bayonet cap and fuse holder.
**Description:** Four-leg PCB stand-off fuse holder.
**Dimensions:** See Dimensions illustration.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
See Specifications table.
**Ratings:**
## **Ratings:**
## **Agency Information:**
See Specifications table.
Volts: — 250V Amps: — 6.3A
See Specifications table notes 1, 2, 5.
**Agency Information:** See Specifications table notes 1, 2.
## **Agency Information:**
**Dimensions - in (mm)**
See Specifications table notes 1, 4. 1.303" Mounting Holes **Dimensions - in (mm)** (33.1mm) **Dimensions - in (mm)** 1.303" Mounting Holes (33.1mm) 0.051" 0.002" +_ Dia. (Typ.) HTC-65M (4-Leg) 0.394" (1.30 + 0.05mm)_ ~~**.886"**~~ **.354"** Printed Circuit (10.0mm) (22.5mm) (9.0mm) Board 0.051"[+] _ 0.002" Dia. (Typ.) 0.394" **.551"** (1.30 + 0.05mm)_ Printed Circuit (10.0mm) (3.5mm) **.10** ~~ct)~~ Board ~~i~~ ‘ ~~+ HB~~ 0.512" **.138"** (13.0mm) 0.512" (3.5mm) S (13.0mm)13.0mm)) **4** S mm) (15.0mm) **.591"** 0.461" **.102"** Dia. Hole (11.7mm) 0.461" (2.6mm) **.051"** Dia. Hole
**==> picture [522 x 122] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.512"<br>S (13.0mm)13.0mm)) 4<br>S mm) (15.0mm) .591"<br>0.461" .102" Dia. Hole<br>(11.7mm) 0.461" (2.6mm) .051" Dia. Hole<br>(11.7mm) (1.3mm)<br>Data Sheet 2110 Data Sheet 2110 Data Sheet 2110<br>7oiele<br>U<br>U E<br>F E<br>F<br>**----- End of picture text -----**<br>
**Specifications Terminals** — Tin-plated brass with 3mm (HTC-35M, -55M) and 4.8mm (HTC-70M).
**Shock Safety** — PC2 (fuse holders). **Agency Information:**
1) cURus: Guide 1ZLT2 & IZLT8, File E14853 2) VDE: 40004457
**Molded Materials** — High temperature thermoplastic that meets the flammability ratings of UL 94VO; Glow Wire Test: 960°C per IEC 695-2-1.
3) VDE: 40004458
4) VDE: 40004459
**Solderability** — In accordance with IEC 68-2-20. **Electrical** — Contact Resistance: _<10mW; Insulation Resistance: _>10MW; Dielectric Strength _>2000Vac.
5) VDE: 40004463
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**93**
**Electronic — PCB & Small Dimension Fuses**
## **PC Board Mount Fuse Holders**
**==> picture [517 x 378] intentionally omitted <==**
**----- Start of picture text -----**<br>
HBH-I (for [1] ⁄4˝ x 1 [1] ⁄4˝ fuses) HBV-I (for [1] ⁄4˝ x 1 [1] ⁄4˝ fuses) HBW-I (for [1] ⁄4˝ x 1 [1] ⁄4˝ fuses)<br>HBH-M (for 5 x 20mm fuses) HBV-M (for 5 x 20mm fuses) HBW-M (for 5 x 20mm fuses)<br>PCB Horizontal PCB Vertical Mount PCB Vertical Mount<br>Mount with Stability Pins without Stability<br>Pins<br>Specifications Specifications<br>Description: PCB Description: PCB<br>Specifications<br>horizontal mount vertical mount fuse<br>Description: PCB<br>fuse holder. holder with stability vertical mount fuse<br>Dimensions: See h pins. \ holder without stability \<br>Dimensions Dimensions: See pins.<br>illustration. Dimensions illustration.<br>Dimensions: See Dimensions<br>Ratings: Ratings: illustration.<br>See Specifications table. See Specifications Ratings:<br>table.<br>See Specifications table.<br>Dimensions - in (mm)<br>Dimensions - in (mm)<br>Dimensions - in (mm)<br>\ \<br>0.531"<br>0.200" (13.5mm)<br>a (5.0mm) 0.510" iF<br>0.510" 0.100" Dia. 4 Holes 0.200" (13.0mm) 0.050" 0.400"<br>(13.0mm) (2.54mm) (5.0mm) Dia. 2 Holes (1.3mm) (10.0mm)<br>0.531" Panel PC Board<br>2mm 4s.onm)4assem)Al (gare 7 (13.5mm) Jn - rs A<br>ee) | 1.855"<br>1.855" 0.400" (47.0mm)<br>eteo24ggo"te) O-1mm) 9.040" Hb.sss"minooetete || | [|] (47.0mm) 0.050" Dia. 2 Holes Lo (10.0mm)<br>(1.3mm)<br>(6.1mm) 4mm min: Panel PC Board |.<br>0.040"<br>0.040" (1.05mm)<br>= (152mm) (1.05mm) ~ a<br>0.580"<br>0.580" (14.9mm)<br>Panel PC Board (14.9mm) —<br>Data Sheet: 2118 Data Sheet: 2118 Data Sheet: 2118<br>HBW<br>HBV<br>**----- End of picture text -----**<br>
**==> picture [198 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
FBI FBM<br>**----- End of picture text -----**<br>
**Fuse Holder Caps (Fit all three shown above)**
## **Specifications**
Electrical Ratings: UL — 16A @ 250V; CSA — 12A @ 250V; VDE — 6.3A @ 250V; SEMKO — 10A @ 250V Insulation resistance — 10 megohm at 500Vdc. Contact resistance — less than 0.005 ohms @ 200mV. Dielectric strength — over 200V/mil. Molded Material: High dielectric molded phenolic with a UL 94V0 flammability rating. Fuse Carrier & Knob: Spring-loaded, bayonet-type. Tin plated brass. Screwdriver slotted.
Mounting: “Kicked” terminals (all models) and stabilizer pins on HBV & HBW models for increased stability. Temperature Rating (RTI): Body: 150ºC, Knob: 130ºC Agency Information: CE, UL Recognized — Guide IZLT2, File EI4853; CSA Certified — Class 6225-01, File 47235 VDE — 4009241 (HBV, HBW) SEMKO — 800444
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**94**
**Electronic — PCB & Small Dimension Fuses**
## **PC Board Fuseclips for 5mm Diameter Fuses**
## **HTC-15M, HTC-140M**
## **PCB Mounted Fuse Holder & Snap-On Cover**
Voltage Rating: 250V, 6.3A, 1.6W
HTC-15M (fuse holder), HTC-140M (natural cover), HTC-150M* (transparent cover)
**Agency Information:** See Specifications table notes 1, 3 on bottom of page 65
*Available in bulk only. Use this format: BK/HTC-150M
**Data Sheet: 2110**
**==> picture [247 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.217 "<br>(26.6mm) 1.047 " (9.0mm) 0.345 " (13.5mm) 0.531 " (5.5mm) Mounting Holes<br>(14.5mm) 0.571 " HTC-140M Cover (22.0mm) 0.866 " 0.177 " 0.059 " [+] _ 0.002"(22.60mm) Dia. (Typ.)0.890 "<br>(4.5mm) (1.50 [_ ][+] .05mm)<br>**----- End of picture text -----**<br>
**==> picture [557 x 516] intentionally omitted <==**
**----- Start of picture text -----**<br>
HTC-200M 0.177" (8.1mm) 0.319" (12.7mm) 0.50"<br>(4.5mm)<br>PCB Mounted Fuseclip 0.929" (3.99mm) 0.157"<br>0.61" (23.6mm)<br>Construction: Tin-plated bronze (15.5mm)<br>Tape and Fan Fold packed (0.79mm) 0.031" (5.5mm) 0.217" (0.3mm) 0.012"<br>Ammo Pack (AP/HTC-200M) 1000 pieces per box 0.50" 0.50"<br>Data Sheet: 2110 (12.7mm) (12.7mm)<br>4.32mm<br>HTC-210M<br>2.54mm 8.73mm 2.29mm 2.54mm<br>6.26mm<br>PCB Mounted Fuseclip with End Stops 3.91mm<br>Data Sheet: 2110 6.22mm 2.85mm 1.46mm 2.54mm<br>1A3399 Series<br>PCB Fuseclips with End Stops & Straight Leads (2.9mm)0.115" (0.062"1.6mm) (3.2mm)0.125" (5.7mm)0.225" (1.6mm)0.030"<br>Catalog Numbers Clip Material* Finish<br>1A3399-01 Beryllium copper* Silver<br>1A3399-04-R Beryllium copper* Bright tin (6.5mm)0.254" (6.0mm)0.237" 0.060" 0.125" 0.188"<br>1A3399-10-R Spring bronze Bright tin (1.5mm) (3.2mm) (4.8mm)<br>*Beryllium copper recommended for amps higher than 15 amps.<br>Data Sheet: 2131<br>1A5018 Series 0.180"<br>(4.57mm) 0.440"<br>PCB High Profile Fuseclips with End Stops & Straight Leads (11.2mm)<br>Catalog Numbers Clip Material* Finish<br>0.230"<br>1A5018-7 Spring bronze Silver (5.84mm) 0.047" 0.140" 0.180"<br>1A5018-10-R Spring bronze Bright tin (1.2mm) (3.7mm) (4.6mm)<br>*Beryllium copper recommended for amps higher than 15 amps.<br>Data Sheet: 2131<br>1A5601 Series 0.344" [+] 0.015" 0.246" 0.250"<br>(8.73mm [+] 0.38mm) (6.3mm) (6.35mm)<br>PCB Fuseclips (0-7A) 0.344" [+] 0.015"<br>Catalog Number Clip Material Finish (8.73mm [+] 0.38mm)<br>1A5601 Cartridge brass Bright tin<br>Data Sheet: 2131 (3.58mm 0.141" [+][+] 0.38mm)0.015" (1.5mm)0.060" (6.75mm)0.266"<br>(0.56mm 0.022" [+][+] 0.002" 0.05mm) (0.81mm 0.05mm)0.032" ++ 0.002"<br>1A5602 Series 0.219"<br>(5.57mm)<br>PCB Fuseclips (0-7A)<br>Catalog Number Clip Material Finish (12.70mm)0.500" (6.35mm)0.250" (3.56mm)0.140"<br>1A5602 Cartridge brass Bright tin 0.093"<br>Data Sheet: 2131 0.216" (2.36mm) 0.047"<br>(5.48mm) LEGS TO FIT (1.19mm)<br>IN 0.052" (1.3mm) DIA.<br>HOLES ON CENTER<br>BUSS BUSS BUSS<br>Fuses<br>Electronic<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**95**
**Electronic — PCB & Small Dimension Fuses**
## **PC Board Fuseclips for[1] ⁄4˝ Diameter Fuses**
**==> picture [525 x 605] intentionally omitted <==**
**----- Start of picture text -----**<br>
1A3398 Series (2.6mm)0.250" (7.1mm) (6.2mm)0.245" (3.94mm)0.155"<br>(6.35mm)<br>PCB Fuseclips without End Stops with Straight Leads 0.410"<br>Catalog Numbers Clip Material Finish (10.4mm) 0.102" Dia.(2.6mm) (7.1mm)0.280"<br>1A3398-07-R Cartridge brass Bright tin<br>Data Sheet: 2131 (1.5mm)0.060"0.320" (3.6mm)0.140" (7.1mm)0.280"<br>(8.13mm)<br>1A1907 Series<br>PCB Fuseclips with End Stops & Straight Leads 0.102" Dia.(2.6mm) (7.1mm)0.280" 0.245" (3.94mm)0.155"<br>Catalog Numbers Clip Material* Finish 0.255" (6.2mm)<br>(6.5mm)<br>1A1907-02 Cartridge brass None/bright dipped 0.410" 0.102" Dia. 0.280"<br>1A1907-03-R High Performance Copper* Bright tin (10.4mm) (2.6mm) (7.1mm)<br>1A1907-05 High Performance Copper* Silver<br>1A1907-06-R*High Performance Copper recommended for amps higher than 15A.Cartridge brass Bright tin (1.5mm)0.060"0.320" (3.6mm)0.140" (7.1mm)0.280"<br>Data Sheet: 2131<br>(8.13mm)<br>1A4533 Series 0.245" 0.155" 0.102"<br>(6.2mm) (3.94mm) (2.6mm)<br>PCB Fuseclips without End Stops or Angled Out Leads<br>0.410"<br>Catalog Numbers Clip Material* Finish (10.4mm)<br>1A4533-01-R High Performance Copper* Bright tin 0.255" (8.13mm)0.320 " (7.11mm)0.280"<br>1A4533-06-R Cartridge brass Bright tin (6.5mm) 0.150" 0.228"<br>*High Performance Copper recommended for amps higher than 15A. Data Sheet: 2131 (1.5mm)0.060" (3.81mm) (5.79mm)(8.20mm)0.323"<br>1A4534 Series 0.245" 0.155" 0.102"<br>(6.2mm) (3.94mm) (2.6mm)<br>PCB Fuseclips with End Stops & Angled Out Leads<br>Catalog Numbers Clip Material* Finish (10.4mm)0.410"<br>1A4534-01-R High Performance Copper* Bright tin 0.255" (8.13mm)0.320 " (7.11mm)0.280"<br>1A4534-06-R*High Performance Copper recommended for amps higher than 15A. Data Sheet: 2131 Cartridge brass Bright tin (6.5mm)(1.5mm)0.060" (3.81mm)0.150" (5.79mm)(8.20mm)0.228"0.323"<br>1A1119 Series<br>0.132"<br>0.285" (3.4mm)<br>Fuseclips with End Stops & Angled In Leads (7.24mm)<br>Catalog Numbers Clip Material* Finish (10.67mm)0.420" 0.187"<br>1A1119-04-R High Performance Copper* Bright tin (4.8mm) 0.312"<br>1A1119-05 High Performance Copper* Silver 0.250" 0.290" (7.9mm)<br>1A1119-10-R Cartridge brass Bright tin (6.5mm)0.080" (3.9mm)0.155" (7.4mm)0.360"<br>*High Performance Copper recommended for amps higher than 15A. (2.03mm) (9.14mm)<br>Data Sheet: 2131<br>1A1120 Series<br>PCB Fuseclips without End Stops or Angled In Leads 0.272”<br>[6.91]<br>Catalog Numbers 1A1120-02 Cartridge brass Clip Material* None/bright dipped Finish 0.250” CL [10.16±0.25]0.400”±.010 Ø [3.3mm±0.08]0.130”±.003 0.187”[4.75] 0.312”[7.92]<br>1A1120-05 High Performance Copper* Silver [6.35] 0.155”±.010<br>[3.94±0.25]<br>1A1120-06-R High Performance Copper* Bright tin 0.080”[2.03] 0.290”±.010<br>1A1120-09-R Cartridge brass Bright tin 0.320”[8.13] 0.363”±.003 [7.37±0.25]<br>*High Performance Copper recommended for amps higher than 15A. [9.22±0.08]<br>**----- End of picture text -----**<br>
*High Performance Copper recommended for amps higher than 15A. **Data Sheet: 2131**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**96**
**Electronic — PCB & Small Dimension Fuses**
## **PC Board Fuseclips for[1] ⁄4˝ Diameter Fuses**
## **5681 & 5682 Series**
|**5681 & 5682 Series**|**5681 & 5682 Series**|**5681 & 5682 Series**|**5681 & 5682 Series**|**5681 & 5682 Series**|**5681 & 5682 Series**|**5681 & 5682 Series**|**5681 & 5682 Series**|**5681 & 5682 Series**|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|<br>**PCB Fuseclips with Mounting Holes For1⁄4˝ Diameter Fuses**<br>**Dimensions (Inches)**<br>**Catalog**<br>**End**<br>**Clip**<br>**B(To**<br>**C**<br>**D**<br>**E**<br>**Hole**<br>**Number**<br>**Stop**<br>**Mat.****<br>**Finish**<br>**End Stop)**<br>**(Contact)**<br>**(Height)**<br>**(Width)**<br>**Dia.**<br>**Ref.**<br>5681-01<br>BeCu<br>Silver<br>5681-08<br>No<br>Spg. Br.<br>Nickel<br>†<br>0.265<br>0.41<br>0.32<br>0.132 Fig. 2<br>5681-15-R<br>Spg. Br.<br>Bright Tin<br>5682-01<br>BeCu<br>Silver<br>0.108<br>5682-02<br>BeCu<br>Silver<br>5682-11-R<br>Yes<br>BeCu<br>Bright Tin<br>0.131<br>0.262<br>0.41<br>0.32<br>0.132 Fig. 1<br>5682-41-R<br>Spg. Br.<br>Bright Tin<br>0.106<br>5682-44-R<br>Spg. Br.<br>Bright Tin<br>0.132|||||||||||||||
||||||||||B||||||
|**Catalog**<br>**Number**|**End**<br>**Stop**|**Clip**<br>**Mat.****|**Finish**||||||||||||
|||||**B(To**<br>**End Stop)**|**C**<br>**(Contact)**|**D**<br>**(Height)**|**E**<br>**(Width)**|**Hole**<br>**Dia.**|||||||
|5681-01|No|BeCu|Silver|†|0.265|0.41|0.32|0.132|||||||
|5681-08||Spg. Br.|Nickel||||||||||||
|5681-15-R||Spg. Br.|Bright Tin||||||||||||
|5682-01|Yes|BeCu|Silver|0.108|0.262|0.41|0.32|0.132|||||||
|5682-02||BeCu|Silver|0.131|||||||||||
|5682-11-R||BeCu|Bright Tin||||||||||||
|5682-41-R||Spg. Br.|Bright Tin|0.106|||||||||||
|5682-44-R||Spg. Br.|Bright Tin|0.132|||||||||||
||||||||||||||||
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**97**
**Electronic — PCB & Small Dimension Fuses**
## **PC Board Fuseclips for[9] ⁄32˝,[13] ⁄32˝ and[9] ⁄16˝ Diameter Fuses**
## **5672 & 5674 Series**
**PCB Fuseclips with Mounting Holes For[9] ⁄32˝ Diameter Fuses**
|**Catalog**<br>**End**<br>**Clip**||||**B(To**|**Dimensions (Inches)**<br>**C**<br>**D**<br>**E**|**Dimensions (Inches)**<br>**C**<br>**D**<br>**E**|**Dimensions (Inches)**<br>**C**<br>**D**<br>**E**|**Hole**||
|---|---|---|---|---|---|---|---|---|---|
|**Number**<br>**Stop**<br>**Mat.****<br>**Finish**||||**End Stop)**|**(Contact)**|**(Height)**|**(Width)**|**Dia.**|**Ref.**|
|5672-11<br>No<br>Spg. Br.<br>Bright Tin||ht Tin||†|0.362|0.52|0.38|0.172|Fig. 2|
|5674-01<br>BeCu<br>Silver||||||||||
|5674-10<br>Yes<br>BeCu<br>Bright Tin<br>0.168<br>0.356<br>0.52<br>0.38<br>0.172 Fig. 1<br>5674-41<br>Spg. Br.<br>Bright Tin<br>**1A3400 Series*****<br>**For**<br>**13/32˝ Diameter Fuses**<br>With End Stops & Straight Leads<br>0.050"<br>0.437"<br>**Dimensional Data**<br>~~SHE~~||||||||||
|(1.27mm)<br>(11.1mm)||||||||||
|0.218"<br>(5.54mm)||||||||||
|||||||||||
|0.142" Dia.||||||||||
|(3.61mm)||||||||||
|0.710"<br>(18.03mm)<br>0.080"<br>(2.03mm)<br>0.470"<br>(11.94mm)<br>0.470"<br>(11.94mm)<br>0.380"<br>(9.65mm)<br>~~oe~~||||||||||
|1A3400-09 & 1A3400-10|||||||||1A3400-12|
**==> picture [83 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>C<br>**----- End of picture text -----**<br>
**==> picture [189 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
D<br>o e<br>E<br>e -<br>Figure 1<br>**----- End of picture text -----**<br>
|Specifications:|Specifications:|||
|---|---|---|---|
|Catalog|Clip||Amp|
|Number|Material|Finish|Rating|
|1A3400-09|SpringBronze|Bright Tin|20A Max.|
|1A3400-10|Beryllium Copper|Silver|30A Max.|
|1A3400-12|SpringBrass|Bright Tin|15A Max.|
***For RoHS compliant version add “-R” option code suffix to part number.
## **5956 & 5960 Series**
**PCB Fuseclips with Mounting Holes For[13] ⁄32˝ Diameter Fuses**
**Dimensions (Inches) Catalog End Clip B (To C D E Hole Number Stop Mat.** Finish End Stop) (Contact) (Height) (Width) Dia. Ref.** C 5956-16 No Spg. Br. Bright Tin † 0.312 0.71 0.47 0.172 Fig. 2 5960-07 BeCu Silver 0.168 0.196 5960-09 BeCu Silver 0.20 0.172 5960-44 ~~=~~ Spg. Br. Nickel 0.20 ~~,~~ 0.197 ~~EL~~ 5960-51 Yes Spg. Br. Bright Dip* 0.168 0.387 0.71 0.47 0.196 Fig. 1 5960-53 Spg. Br. Bright Dip* 0.20 0.172 5960-61-R Spg. Br. Bright Tin 0.168 0.196 D 5960-62-R Spg. Br. Bright Tin 0.168 0.132 5960-63-R Spg. Br. Bright Tin 0.20 0.172 5960-64-R Spr. Br. Bright Tin 0.20 0.128 S ~~y E a ae~~ **5591 & 5592 Series PCB Fuseclips with Mounting Holes For[9] ⁄16˝ Diameter Fuses** Figure 2 **Dimensions (Inches) Catalog End Clip B (To C D E Hole Number Stop Mat.** Finish End Stop) (Contact) (Height) (Width) Dia. Ref.** 5591-42 Spg. Br. Bright Dip* Yes 0.26 0.51 0.89 0.60 0.172 Fig. 1 5591-52-R Spg. Br. Bright Tin ~~St~~ 5592-01 No BeCu Silver 0.252 0.56 0.875 0.60 0.20 Fig. 2 * Bright Dip is actually treated bare metal with no plating. ** Spg. Br. — Spring Bronze; BeCu — Beryllium Copper. † Hole in center of both clip and contact area. **Data Sheet: 2132**
**Data Sheet: 2132**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**98**
## **Medium Voltage Fuses**
## **Section Contents**
**Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100**
## **E-Rated Fuses**
For transformers & feeders . . . . . . . . . . . . . . . . . . 101-104 CL-14 & bolt-in . . . . . . . . . . . . . . . . . . . . . . . . . . . .105-107 For potential & small power transformers . . . . . . . . 108-110 **PT fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 R-Rated fuses for motor circuit protection . .112-114 British IEC fuses for motor circuit protection . . . 115 DIN IEC fuses for transformer protection . . . . . . 116 Expuision Fuse Links . . . . . . . . . . . . . . . . . . 117-118 EEI-NEMA Type K & T and Type H & N fuses . . . 119 Fuseclips for medium and high voltage fuses . . .120**
Scan this tag to get the latest product information for Medium Voltage Fuses.
**99**
**Medium Voltage Fuses**
## **Medium Voltage Fuses**
## **Worldwide Circuit Protection Solutions**
Bussmann is a world-leading supplier of medium voltage fuses. Each product is backed by an efficient worldwide distribution network with unrivaled service and technical support. Bussmann circuit protection solutions comply with major international standards: ANSI, BS, DIN, IEC and UL.
## **Fuse Types**
Medium voltage fuses generally fit into two categories – expulsion fuses and current limiting fuses. The definitions per ANSI C37.40 are:
within this range. It is possible for the fuse to be exposed to an overcurrent lower than the value given by the one hour criteria. In that case, a different overcurrent protection device would be required to interrupt the overcurrent.
3. Back-up – defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum interrupting rating current down to the minimum interrupting current.” The minimum interrupting current is the lowest current that the fuse will be able to clear properly. This creates a need to place a low current interrupting device, such as motor overloads, in series with the back-up rated fuse.
## **E- and R-Rated Fuses**
Expulsion Fuse: “A vented fuse in which the expulsion effect of the gases produced by internal arcing, either alone or aided by other mechanisms results in current interruption.” Expulsion fuses will limit the duration of an overcurrent event, but they will not limit the magnitude of fault current.
Current Limiting Fuse: “A fuse unit that, when in its currentresponsive element is melted by a current within the fuse’s specified current-limiting range, abruptly introduces a high resistance to reduce current magnitude and duration, resulting in subsequent current interruption.” A current limiting fuse will reduce the magnitude a fault current as well as limit the duration of the overcurrent event when operating in its current limiting range. Bussmann offers a broad range of current limiting fuses for protection of feeders, transformers and motor circuits designed to ANSI, BS, DIN and IEC standards.
## **Medium Voltage Current Limiting Fuses**
Current limiting fuses are classified into three categories:
1. Full Range – defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the minimum continuous current that causes the melting of the fusible element(s), when the fuse is applied at the maximum ambient temperature specified by the manufacturer.” It is able to interrupt any current that will melt its element.
In North America, current limiting fuses typically fall into the category of E-Rated fuses and R-Rated fuses. Bussmann also offers a wide range of current limiting fuses designed to BS, DIN and IEC standards.
E-Rated fuses are used to protect feeder circuits, power transformers and potential transformers. E-Rated fuses have defined current response times specified by ANSI C37.46. E-Rated fuses 100A and below must melt in 300sec at an rms current within the range of 200% to 240% of the continuous current rating. E-Rated fuses above 100A must melt in 600sec at an rms current within the range of 240% to 264% of the continuous current rating of the fuse. Bussmann offers a wide variety of full range and general purpose E-Rated fuses from 2.4kV up to 38kV.
R-Rated fuses are back-up fuses that provide short-circuit protection for motor circuits. They are applied with MV motor starters which provide the overload protection for the circuit. R-Rated fuses also have defined current response times specified by ANSI C37.46. R-Rated fuses will melt in a range of 15 – 35sec at a current equal to 100 times the “R” rating. Bussmann offers 2.4kV, 5.08kV, 7.2kV and 8.3kV R-Rated fuses for motor circuit protection.
2. General Purpose – defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the current that causes melting of the fusible element(s) in one hour.” Not all currents fall
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**100**
**Medium Voltage Fuses**
## **E-Rated Fuses for Transformers and Feeders**
## **MV055**
## **Specifications**
**Description:** E-rated medium, voltage current-limiting fuses for transformer and feeder protection.
**Dimensions:** See Catalog Numbers table.
**Construction:** Silver ribbon element surrounded by silica filler housed in a fiberglass tube and plated endcaps. An epoxy paint protects the fuse tube from the surrounding environment.
## **Ratings:**
Volts: — 5.5kV (10-450A)
Amps: — 5-450A (5.5kV)
IR: — 50kA Sym. Max
**Agency Information:** Meets E requirements per ANSI C37.46, Meets full range requirements per ANSI C37.40.
## **Features and Benefits**
- MV055 Standard clip center distance of 12 inches with 2 and 3 inch barrel diameters for retrofitting in existing hardware
- Open fuse indicator for ease in troubleshooting
- Full range rating with 50KA Interrupting Rating
## **5.5kV Catalog Numbers**
|**5.5kV Catalog Numbers**<br>**Catalog**<br>**Numbers**|**5.5kV Catalog Numbers**<br>**Amp**<br>**Rating**<br>~~ee~~|**5.5kV Catalog Numbers**<br>**Min**<br>**Melt**<br>**I2t**<br>~~ee~~|**Max**<br>**Clear**<br>**I2t**|**Dimensions (in)***<br>**Clip**<br>**Length**<br>**Dia.**<br>**Center Barrels**<br>15.75<br>3<br>12<br>1<br>15.75<br>3<br>12<br>1<br>15.75<br>3<br>12<br>2<br>15.75<br>12<br>~~1~~<br>~~1~~<br>2<br>2<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|**Dimensions (in)***<br>**Clip**<br>**Length**<br>**Dia.**<br>**Center Barrels**<br>15.75<br>3<br>12<br>1<br>15.75<br>3<br>12<br>1<br>15.75<br>3<br>12<br>2<br>15.75<br>12<br>~~1~~<br>~~1~~<br>2<br>2<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|**Dimensions (in)***<br>**Clip**<br>**Length**<br>**Dia.**<br>**Center Barrels**<br>15.75<br>3<br>12<br>1<br>15.75<br>3<br>12<br>1<br>15.75<br>3<br>12<br>2<br>15.75<br>12<br>~~1~~<br>~~1~~<br>2<br>2<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|
|---|---|---|---|---|---|---|
|||||**Length**|**Clip**<br>**Dia.**<br>**Center**|**Clip**<br>**Center **|
|MV055F1CAX10E|10<br>~~ee~~|850<br>~~ee~~|8,000||||
|MV055F1CAX15E|15<br>~~ee~~|2,070<br>~~ee~~<br>~~ee~~|8,000<br>11,000||||
|MV055F1CAX20E|20<br>~~ee ~~<br>~~ee~~|2,370<br> ~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|23,000<br>~~ee~~<br>~~ee~~|~~ee~~|||
|MV055F1CAX25E|25<br>~~ee~~<br>~~ee~~<br>~~ee~~|4,650<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~**ee**~~|31,000<br>~~ee~~<br>~~ee~~<br>~~ee~~|~~ee~~|~~1~~||
|MV055F1CAX30E|30<br>~~ee~~<br>~~ee~~<br>~~ee~~|9,490<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~**ee**~~|45,000<br>~~ee~~<br>~~ee~~<br>~~ee~~|~~ee~~|~~1~~||
|MV055F1CAX40E|40<br>~~ee~~<br>~~ee~~|9,490<br>~~ee~~<br>~~**ee**~~<br>~~ee~~|45,000<br>~~ee~~||||
|MV055F1CAX50E|50<br>~~ee~~<br>~~es~~|13,600<br>~~**ee**~~<br>~~es~~<br>~~ee~~<br>~~ee~~|90,000<br>~~es~~||||
|MV055F1CAX65E|65<br>~~es~~<br>~~ee~~|30,700<br>~~es~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|181,000<br>~~es~~<br>~~ee~~<br>~~ee~~|~~ee~~|||
|MV055F1DAX10E|10<br>~~ee~~<br>~~ee~~<br>~~ee~~|850<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~e~~~~**e**~~|8,000<br>~~ee~~<br>~~ee~~<br>~~ee~~|15.75<br>~~ee~~|3|12|
|MV055F1DAX15E|15<br>~~ee~~<br>~~ee~~<br>~~ee~~|2,070<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~e~~~~**e**~~<br>~~e~~|12,000<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|~~ee~~<br>~~ee~~|||
|MV055F1DAX20E|20<br>~~ee~~<br>~~ee~~<br>~~es~~|2,370<br>~~ee~~<br>~~e~~~~**e**~~<br>~~e~~<br>~~ee~~<br>|23,000<br>~~ee~~<br>~~ee~~|~~ee~~|||
|MV055F1DAX25E|25<br>~~ee~~<br>~~ee~~<br>~~es~~<br>~~ee~~|4,650<br>~~e~~~~**e**~~<br>~~e~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|31,000<br>~~ee~~<br>~~ee~~|~~ee~~|||
|MV055F1DAX30E|30<br>~~ee~~<br>~~es~~<br>~~ee~~|9,490<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|45,000<br>~~ee~~||||
|MV055F1DAX40E|40<br>~~es ~~<br>~~ee~~|9,490<br>~~ee~~<br> ~~ee~~<br>~~ee~~<br>~~ee~~|45,000|15.75||12|
|MV055F1DAX50E|50<br> <br>~~ee~~<br>~~ee~~|13,600<br> ~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|90,000<br>~~ee~~||||
|MV055F1DAX65E|65<br>~~ee~~<br>~~ee~~<br>~~es~~|30,700<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>|181,000<br>~~ee~~<br>~~ee~~||||
|MV055F1DAX80E|80<br>~~ee~~<br>~~ee~~<br>~~es~~|54,600<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|270,000<br>~~ee~~<br>~~ee~~||||
|MV055F1DAX100E|100<br>~~ee~~<br>~~es~~|116,200<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|580,000<br>~~ee~~||2||
|MV055F1DAX125E|125<br>~~es ~~<br>~~ee~~<br>~~ee~~|167,400<br>~~ee~~<br> ~~ee~~<br>~~ee~~<br>~~ee~~<br>~~**ee**~~|600,000<br>~~ee~~|15.75|3|12|
|MV055F1DAX150E|150<br>~~ee~~<br>~~ee~~|218,700<br>~~ee~~<br>~~ee~~<br>~~**ee**~~|786,000<br>~~ee~~||||
|MV055F1DAX175E|175<br>~~ee~~<br>~~ee~~|227,900<br>~~ee~~<br>~~**ee**~~<br>~~ee~~|1,100,000<br>~~ee~~||||
|MV055F1DAX200E|200<br>~~ee~~<br>~~ee~~|297,600<br>~~**ee**~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|1,520,000<br>~~ee~~<br>~~ee~~|~~ee~~|||
|MV055F2DAX250E|250<br>~~ee~~<br>~~ee~~<br>~~ee~~|669,600<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~**ee**~~|2,400,000<br>~~ee~~<br>~~ee~~<br>~~ee~~|15.75<br>~~ee~~|3|12|
|MV055F2DAX300E|300<br>~~ee~~<br>~~ee~~<br>~~ee~~|874,800<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~**ee**~~|3,149,000<br>~~ee~~<br>~~ee~~<br>~~ee~~|~~ee~~|||
|MV055F2DAX350E|350<br>~~ee~~<br>~~ee~~|911,600<br>~~ee~~<br>~~**ee**~~|4,376,000<br>~~ee~~||||
|MV055F2DAX400E|400<br>~~ee~~<br>~~ee~~|1,190,400<br>~~**ee**~~<br>~~ee~~<br>~~ee~~|6,071,000<br>~~ee~~||||
|MV055F2DAX450E|450<br>~~ee~~<br>~~ee~~|1,555,000<br>~~ee~~<br>~~ee~~<br>~~ee~~|9,796,000<br>~~ee~~<br>~~ee~~||||
1” = 25.4mm Recommended Fuse Clips - see page 120
- Double pulsed at 90% of minimum I[2] t to establish manufacturing reliability
## **MV055 Typical Applications**
- 5.0kV Transformer Primary Protection
- 5.0kV Feeder Circuit Protection
- 5.0kV Voltage Switches
- 5.0kV Metal-enclosed Switchgear
## **Dimensions - in**
## **Diagram 1**
## **Diagram 2**
**Data Sheet: 6700**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**101**
**Medium Voltage Fuses**
## **E-Rated Fuses for Transformers and Feeders**
## **MV155**
**Specifications Description:** E-rated medium, voltage current-limiting fuses for transformer and feeder protection.
**Dimensions:** See Catalog Numbers table.
**Construction:** Silver ribbon element surrounded by silica filler housed in a fiberglass tube and plated endcaps. An epoxy paint protects the fuse tube from the surrounding environment.
## **Ratings:**
Volts: — 15.5kV (5-200A) Amps: — 5-200A (15.5kV)
IR: — 50kA Sym. Max
**Agency Information:** Meets E requirements per ANSI C37.46, Meets full range requirements per ANSI C37.40.
## **Features and Benefits**
- MV155 Standard clip center distance of 15 and 18 inches with 2 and 3 inch barrel diameters for retrofitting in existing hardware
- Open fuse indicator for ease in troubleshooting
- Full range rating with 50kA Interrupting Rating
- Double pulsed at 90% of minimum I[2] t to establish manufacturing reliability
## **Data Sheet: 6700**
## **15.5kV Catalog Numbers**
|**15.5kV Catalog Numbers**<br>**Catalog**<br>**Numbers**|**15.5kV Catalog Numbers**<br>**Amp**<br>**Rating**|**15.5kV Catalog Numbers**<br>**Min**<br>**Melt**<br>**I2t**|**Max**<br>**Clear**<br>**I2t**|**Dimensions***<br>**Clip**<br>**Length**<br>**Dia.**<br>**Center Barrels**<br>18.75<br>15<br>1<br>1<br>18.75<br>3<br>15<br>1<br>18.75<br>3<br>15<br>2<br>21.75<br>3<br>18<br>1<br>21.75<br>3<br>18<br>2<br>18.75<br>~~2~~<br>15<br>1<br>~~2~~<br>2<br>1<br>~~18~~<br>~~21.75~~<br>~~ee~~<br>~~ee~~|**Dimensions***<br>**Clip**<br>**Length**<br>**Dia.**<br>**Center Barrels**<br>18.75<br>15<br>1<br>1<br>18.75<br>3<br>15<br>1<br>18.75<br>3<br>15<br>2<br>21.75<br>3<br>18<br>1<br>21.75<br>3<br>18<br>2<br>18.75<br>~~2~~<br>15<br>1<br>~~2~~<br>2<br>1<br>~~18~~<br>~~21.75~~<br>~~ee~~<br>~~ee~~|**Dimensions***<br>**Clip**<br>**Length**<br>**Dia.**<br>**Center Barrels**<br>18.75<br>15<br>1<br>1<br>18.75<br>3<br>15<br>1<br>18.75<br>3<br>15<br>2<br>21.75<br>3<br>18<br>1<br>21.75<br>3<br>18<br>2<br>18.75<br>~~2~~<br>15<br>1<br>~~2~~<br>2<br>1<br>~~18~~<br>~~21.75~~<br>~~ee~~<br>~~ee~~|
|---|---|---|---|---|---|---|
|||||**Length**|**Dia.**|**Clip**<br>**Center **|
|MV155F1CBX5E|5|180|2,900|18.75|1|15|
|MV155F1CBX7E|7|850|2,900<br>8,000||||
|MV155F1CBX10E|10|850|8,000||||
|MV155F1CBX15E|15|2,070|12,000||||
|MV155F1CBX20E|20|2,370|23,000||||
|MV155F1CBX25E|25<br>~~a~~|2,370<br>4,650<br>~~a~~|23,000<br>31,000<br>~~ee~~||||
|MV155F1CBX30E|30<br>~~a ~~<br>~~a~~|9,490<br> ~~a ~~<br>|45,000<br> ~~ee~~<br>||||
|MV155F1DBX10E|10<br>~~ajf~~|850<br>~~jf~~|8,000<br>~~jf~~|18.75|3|15|
|MV155F1DBX15E|15<br>~~jf~~<br>~~a~~|2,070<br>~~jf~~<br>~~a~~|12,000<br>~~jf~~||||
|MV155F1DBX20E|20<br>~~a ~~<br>~~ee~~|2,370<br> ~~a~~<br>~~ee~~|23,000<br>~~ee~~||||
|MV155F1DBX25E|25<br>~~ee~~<br>~~a~~|4,650<br>~~ee~~<br>|31,000<br>~~ee~~<br>|18.75||15|
|MV155F1DBX30E|30<br>~~aee~~<br>~~a~~|9,490<br>~~ee~~<br>~~ee~~|45,000<br>~~ee~~||||
|MV155F1DBX40E|40<br>~~ee~~<br>~~a~~|9,490<br>~~ee~~<br>~~ee~~|45,000<br>~~ee~~||||
|MV155F1DBX50E|50<br>~~a~~<br>~~a~~<br>~~re~~|9,490<br>13,600<br>~~ee~~<br>~~a~~<br>~~ee~~|45,000<br>90,000<br>~~ee~~|~~ee~~|||
|MV155F1DBX65E|65<br>~~a ~~<br>~~re~~|30,700<br> ~~a~~<br>~~ee~~|181,000<br>~~ee~~|~~ee~~|||
|MV155F1DBX80E|80<br>~~re~~<br>~~a~~|54,600<br>~~ee~~<br>~~a~~|270,000<br>~~ee~~|~~ee~~|||
|MV155F1DBX100E|100<br>~~a ~~<br>~~jf~~<br>~~a~~|116,200<br> ~~a~~<br>~~jf~~<br>~~ee~~|600,000<br>~~jf~~||||
|MV155F2DBX125E|125<br>~~jf~~<br>~~a~~|123,000<br>~~jf~~<br>~~ee~~|677,000<br>~~jf~~|18.75|3<br>~~2~~|15|
|MV155F2DBX150E|150<br>~~a~~<br>~~ee~~|218,700<br>~~ee~~<br>~~ee~~|1,287,000<br>~~ee~~||~~2~~||
|MV155F2DBX175E|175<br>~~ee~~<br>~~aa~~|314,700<br>~~ee~~<br>~~aa~~|1,689,000<br>~~ee~~<br>~~aa~~||||
|MV155F2DBX200E|200<br>~~aa~~<br>~~a~~<br>~~ee~~|465,100<br>~~aa~~<br>~~aa~~<br>~~ee~~|2,405,000<br>~~aa~~<br>~~ee~~|~~ee~~|||
|MV155F1DCX65E|65<br>~~a~~<br>~~ee~~<br>~~a~~|30,700<br>~~aa~~<br>~~ee~~<br>~~ee~~|181,000<br>~~ee~~|21.75<br>~~ee~~|3|18|
|MV155F1DCX80E|80<br><br>~~ee~~<br>~~a~~|54,600<br>~~a~~<br>~~ee~~<br>~~ee~~|270,000<br>~~ee~~|~~ee~~|||
|MV155F1DCX100E|100<br>~~a~~<br>~~ee~~|116,200<br>~~ee~~<br>~~ee~~|600,000<br>~~ee~~||||
|MV155F2DCX125E|125<br>~~ee~~<br>~~a ee~~<br>~~a~~|123,000<br>~~ee~~<br>~~ee~~<br>~~el~~<br>|677,000<br>~~ee~~<br>~~ee~~<br>|21.75<br>~~21.75~~|3|18<br>~~18~~|
|MV155F2DCX150E|150<br>~~a ee~~<br>~~ee~~<br>~~a~~|218,700<br>~~ee~~<br>~~ee~~<br>~~el~~<br>|1,287,000<br>~~ee~~<br>~~ee~~<br>|~~21.75~~||~~18~~|
|MV155F2DCX175E|175<br>~~a~~|314,700<br>~~el~~<br>~~ee~~|1,689,000<br>~~ee~~||||
|MV155F2DCX200E|200<br>~~a ~~<br>~~rs~~|465,100<br>~~el~~<br> ~~ee~~<br>~~rs~~|2,405,000<br>~~ee~~<br>~~rs~~||||
*1” = 25.4mm.
Recommended Fuse Clips - see page 120
## **MV155 Typical Applications**
- 15.0kV Transformer Primary Protection
- 15.0kV Feeder Circuit Protection
- 15.0kV Voltage Switches
- 15.0kV Metal-enclosed Switchgear
## **Dimensions - in**
## **Diagram 1**
## **Diagram 2**
**Data Sheet: 6701**
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**102**
**Medium Voltage Fuses**
## **E-Rated Fuses for Transformer & Feeders**
## **JCX, JCY, JCU, JCZ and JDZ**
**Specifications Description:** Indoor/enclosure E-rated medium voltage, currentlimiting fuses for feeders and power transformers with blown fuse indication.
**Dimensions:** See Catalog Numbers table.
## **Features and Benefits**
- Physically dimensioned for retrofitting in existing hardware
- Open fuse indicator for ease in troubleshooting
- Full range ANSI classification
## **Typical Applications**
- Medium Voltage Transformer Primary Protection
- Medium Voltage Feeder Circuit Protection
- Medium Voltage Switches
- Medium Voltage Metal-enclosed Switchgear
**Construction:** plated ferrules.
## **Ratings:**
Volts: — 2750-8300V - See Catalog Numbers table for details
- Amps: —[1] ⁄2-750A
- IR: — 40-63kA Sym
- 60-100kA ASYM
- See Catalog Numbers table for details
|**Catalog Numbers**<br>~~ee~~|**Catalog Numbers**<br>~~ee~~|~~ee~~|~~ee~~|~~es~~<br>~~ee~~|~~es~~<br>~~ee~~|||
|---|---|---|---|---|---|---|---|
|**Catalog Numbers**<br>**Catalog**<br>**Numbers**<br>~~ee~~|**Catalog Numbers**<br>**Amp**<br>**Rating**<br>~~ee~~<br>~~a~~|**Maximum**<br>**Design Voltage**<br>~~ee~~<br>~~Ce~~|**Construction**<br>~~ee~~<br>~~Ce~~|**Maximum Interrupting Capacity**<br>~~es~~<br>~~ee~~||**Dimensions- in (mm)**||
|||||**Amps (Asym.)**<br>~~es~~|**Amps (Sym.)**<br>~~ee~~|**Length**|**Diameter**|
|**2400V; E-Rated; Indoor/Enclosure**<br>~~ee~~<br>~~ee~~<br>~~Ce~~<br>~~a~~|||~~ee~~<br>~~Ce~~|~~es~~|~~ee~~|||
|**2400V; ERated; Indoor/Enclosure**<br>JCX-1E|**Rated; Indoor/Enclosure**<br>1<br>~~a~~|**Rated; Indoor/Enclosure**<br>2750<br>~~Ce~~|Single<br>~~Ce~~|60,000|40,000|9.19 (233.38)|2 (50.8)|
|JCX-2E|2<br>~~a~~|2750<br>~~Ce~~|Single<br>Single<br>~~Ce~~|60,000<br>60,000|40,000<br>40,000|9.19 (233.38)<br>9.19 (233.38)|2 (50.8)<br>2 (50.8)|
|JCX-3E|3<br>~~a~~<br>~~a~~|2750<br>~~Ce~~<br>~~a~~|Single<br>Single<br>~~Ce~~<br>~~OO~~|60,000<br>60,000<br>~~Oooo~~|40,000<br>40,000<br>~~Oooo~~|9.19 (233.38)<br>9.19 (233.38)<br>~~Oooo~~|2 (50.8)<br>2 (50.8)|
|JCX-5E|5<br>~~a~~<br>~~Oo~~|2750<br>~~a~~<br>~~Oo~~|Single<br>Single<br>~~Oo~~<br>~~OO~~<br>~~oo~~|60,000<br>~~Oo~~<br>~~Oooo~~<br>~~OO~~|40,000<br>~~Oo~~<br>~~Oooo~~<br>~~ooo~~|9.19 (233.38)<br>~~Oo~~<br>~~Oooo~~<br>~~ooo~~|2 (50.8)|
|JCX-7E<br>~~POE~~|7<br>~~Oo~~<br>~~Oo~~<br>~~POE~~|2750<br>~~Oo~~<br>~~Oo~~<br>~~POE~~|Single<br>Single<br>~~Oo~~<br>~~OO ~~<br>~~Oo~~<br>~~oo~~<br>~~OO~~|60,000<br>~~Oo~~<br> ~~Oooo~~<br>~~Oo~~<br>~~OO~~<br>~~Oooo~~|40,000<br>~~Oo~~<br>~~Oooo~~<br>~~Oo~~<br>~~ooo~~<br>~~Oooo~~|9.19 (233.38)<br>9.19 (233.38)<br>~~Oo~~<br>~~Oooo~~<br>~~Oo~~<br>~~ooo~~<br>~~Oooo~~|2 (50.8)<br>2 (50.8)|
|JCX-10E<br>~~POE~~|10<br>~~Oo~~<br>~~Oo~~<br>~~POE~~|2750<br>~~Oo~~<br>~~Oo~~<br>~~POEoo~~|Single<br>Single<br>~~Oo~~<br>~~oo ~~<br>~~Oo~~<br>~~OO~~<br>~~I~~|60,000<br>~~Oo~~<br> ~~OO~~<br>~~Oo~~<br>~~Oooo~~<br>~~EET~~|40,000<br>~~Oo~~<br>~~ooo~~<br>~~Oo~~<br>~~Oooo~~<br>~~EET~~|9.19 (233.38)<br>9.19 (233.38)<br>~~Oo~~<br>~~ooo~~<br>~~Oo~~<br>~~Oooo~~<br>~~EET~~|2 (50.8)<br>2 (50.8)|
|JCX-15E<br>~~POE~~|15<br>~~Oo~~<br>~~POE~~|2750<br>~~Oo~~<br>~~POEoo~~|Single<br>Single<br>~~Oo~~<br>~~OO~~<br>~~I~~|60,000<br>80,000<br>~~Oo~~<br>~~Oooo~~<br>~~EET~~|40,000<br>50,000<br>~~Oo~~<br>~~Oooo~~<br>~~EET~~|9.19 (233.38)<br>9.5 (241.3)<br>~~Oo~~<br>~~Oooo~~<br>~~EET~~|2 (50.8)<br>2.1 (53.34)|
|JCX-20E<br>~~POE~~|20<br>~~POE~~<br>~~a~~|2750<br>~~POE oo~~<br>~~a~~|Single<br>~~OO ~~<br>~~I~~<br>~~a~~|80,000<br> ~~Oooo~~<br>~~EET~~<br>~~a~~|50,000<br>~~Oooo~~<br>~~EET~~<br>~~a~~|9.5 (241.3)<br>~~Oooo~~<br>~~EET~~<br>~~a~~|2.1 (53.34)|
|JCX-25E|25<br>~~a~~<br>~~a~~|2750<br>~~a~~<br>~~a~~|Single<br>Single<br>~~a~~<br>~~a~~|80,000<br>~~a~~<br>~~a~~|50,000<br>~~a~~<br>~~a~~|9.5 (241.3)<br>9.5 (241.3)<br>~~a~~<br>~~a~~|2.1 (53.34)<br>2.1 (53.34)|
|JCX-30E|30<br>~~a~~<br>~~a~~|2750<br>~~a~~<br>~~a~~|Single<br>Single<br>~~a~~<br>~~a~~|80,000<br>~~a~~<br>~~a~~|50,000<br>~~a~~<br>~~a~~|9.5 (241.3)<br>10.81 (276.35)<br>~~a~~<br>~~a~~|2.1 (53.34)<br>3 (76.2)|
|JCX-40E|40<br>~~a~~<br>~~a~~|2750<br>~~a~~<br>~~a~~|Single<br>Single<br>~~a~~<br>~~a~~|80,000<br>80,000<br>~~a~~<br>~~a~~|50,000<br>50,000<br>~~a~~<br>~~a~~|10.81 (276.35)<br>10.81 (276.35)<br>~~a~~<br>~~a~~|3 (76.2)<br>3 (76.2)|
|JCX-50E<br>~~POE~~|50<br>~~a~~<br>~~OO~~<br>~~POE~~|2750<br>~~a~~<br>~~OO~~<br>~~POE~~|Single<br>Single<br>~~a~~<br>~~OO~~<br>~~OO~~|80,000<br>80,000<br>~~a~~<br>~~OO~~<br>~~Oooo~~|50,000<br>50,000<br>~~a~~<br>~~OO~~<br>~~Oooo~~|10.81 (276.35)<br>10.81 (276.35)<br>~~a~~<br>~~OO~~<br>~~Oooo~~|3 (76.2)<br>3 (76.2)|
|JCX-65E<br>~~POE~~|65<br>~~OO~~<br>~~Oo~~<br>~~POE~~|2750<br>~~OO~~<br>~~Oo~~<br>~~POEOo~~|Single<br>Single<br>~~OO~~<br>~~Oo~~<br>~~OO~~<br>~~oT EE~~|80,000<br>~~OO~~<br>~~Oo~~<br>~~Oooo~~<br>~~EE~~|50,000<br>~~OO~~<br>~~Oo~~<br>~~Oooo~~<br>~~EE~~|10.81 (276.35)<br>~~OO~~<br>~~Oo~~<br>~~Oooo~~<br>~~ETT~~|3 (76.2)|
|JCX-80E<br>~~POE~~|80<br>~~Oo~~<br>~~POE~~|2750<br>~~Oo~~<br>~~POEOo~~|Single<br>Single<br>~~Oo~~<br>~~OO~~<br>~~oT EE~~|80,000<br>~~Oo~~<br>~~Oooo~~<br>~~EE~~|50,000<br>~~Oo~~<br>~~Oooo~~<br>~~EE~~|10.81 (276.35)<br>10.81(276.35)<br>~~Oo~~<br>~~Oooo~~<br>~~ETT~~|3 (76.2)<br>3(76.2)|
|JCX-100E<br>~~POE~~|100<br>~~POE~~<br>~~a~~|2750<br>~~POE Oo~~<br>~~a~~|Single<br>~~OO ~~<br>~~oT EE~~<br>~~a~~|80,000<br> ~~Oooo~~<br>~~EE~~<br>~~a~~|40,000<br>~~Oooo~~<br>~~EE~~<br>~~a~~|10.81(276.35)<br>~~Oooo~~<br>~~ETT~~<br>~~a~~|3 (76.2)|
|JCX-125E|125<br>~~a~~<br>~~a~~|2750<br>~~a~~<br>~~a~~|Single<br>~~a~~<br>~~a~~|80,000<br>~~a~~<br>~~a~~|50,000<br>~~a~~<br>~~a~~|10.81 (276.35)<br>~~a~~<br>~~a~~|3 (76.2)|
|JCX-150E|150<br>~~a~~<br>~~a~~|2750<br>~~a~~<br>~~a~~|Single<br>Single<br>~~a~~<br>~~a~~|80,000<br>~~a~~<br>~~a~~|50,000<br>~~a~~<br>~~a~~|10.81 (276.35)<br>~~a~~<br>~~a~~|3 (76.2)|
|JCX-200E|200<br>~~a~~<br>~~a~~|2750<br>~~a~~<br>~~a~~|Single<br>Single<br>~~a~~<br>~~a~~|80,000<br>~~a~~<br>~~a~~|50,000<br>~~a~~<br>~~a~~|10.81 (276.35)<br>10.81 (276.35)<br>~~a~~<br>~~a~~|3 (76.2)<br>3 (76.2)|
|JCX-225E|225<br>~~a~~<br>~~a~~|2750<br>~~a~~<br>~~a~~|Single<br>Single<br>~~a~~<br>~~a~~|80,000<br>~~a~~<br>~~a~~|50,000<br>~~a~~<br>~~a~~|10.81 (276.35)<br>10.81 (276.35)<br>~~a~~<br>~~a~~|3 (76.2)<br>3 (76.2)|
|JCX-250E/280X<br>~~Ne~~|250/280<br>~~a~~<br>~~a~~<br>~~Ne~~|2750<br>~~a~~<br>~~a~~<br>|Single<br>Double<br>~~a~~<br>~~a~~<br>|80,000<br>80,000<br>~~a~~<br>~~a~~<br>|50,000<br>50,000<br>~~a~~<br>~~a~~<br>|10.81 (276.35)<br>10.81 (276.35)<br>~~a~~<br>~~a~~<br>|3 (76.2)<br>3 (76.2)|
|JCX-300E/325X<br>~~Ne~~|300/325<br>~~a~~<br>~~Ne~~|2750<br>~~a~~<br>|Double<br>~~a~~<br>|80,000<br>~~a~~<br>|50,000<br>~~a~~<br>|10.81 (276.35)<br>~~a~~<br>|3 (76.2)|
|JCX-350X<br>~~Ne~~|350<br>~~Ne~~|2750<br>|Double<br>|80,000<br>|50,000<br>|10.81 (276.35)<br>10.81(276.35)<br>|3 (76.2)<br>3(76.2)|
|JCX-400X<br>~~Ne~~|400<br>~~Nea~~|2750<br>~~a~~|Double<br>~~a~~|80,000<br>~~a~~|50,000<br>~~a~~|10.81(276.35)<br>~~a~~|3(76.2)|
|JCX-450X<br>|450<br>~~a~~<br>~~a~~|2750<br>~~a~~<br>~~a~~|Double<br>~~a~~<br>~~a~~|80,000<br>~~a~~<br>~~a~~|50,000<br>~~a~~<br>~~a~~|10.81 (276.35)<br>~~a~~<br>~~a~~|3 (76.2)|
|**5500V; E-Rated; Indoor/Enclosure**|**Rated; Indoor/Enclosure**<br>~~a~~|**Rated; Indoor/Enclosure**<br>~~a~~|~~a~~|~~a~~|~~a~~|~~a~~||
Contact Bussmann for the latest product information on E-Rated fuses for transformer and feeder protection. Recommended fuseclips: see page 120 - 1A0065, 9078A67G04, A3354730
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**103**
**Medium Voltage Fuses**
## **E-Rated Fuses for Transformer & Feeders**
## **- Catalog Numbers: E Rated; Indoor/Enclosure**
|<br>**Catalog**<br>**Numbers**|<br>**Amp**<br>**Rating**|<br>**Maximum**<br>**Design Voltage**|<br>**Construction**|**Maximum Interrupting Capacity**|**Maximum Interrupting Capacity**|**Dimensions- in (mm)**|**Dimensions- in (mm)**|
|---|---|---|---|---|---|---|---|
|||||**Amps. (Asym.)**|**Amps. (Sym.)**|**Length**|**Diameter**|
|<br>**5500V; E-Rated; Indoor/Enclosure**||||||||
|<br>JCU-10E|<br>10|<br>5500|Single|80,000|50,000|17.81 (452.4)|3 (76.2)|
|JCU-15E|15|5500|Single|80,000|50,000|<br>12.88 (327.0)|<br>2.1 (53.34)|
|JCU-20E|20|5500|Single|80,000|50,000|<br>12.88 (327.0)|<br>2.1 (53.34)|
|JCU-25E|25|5500|Single|80,000|50,000|<br>12.88 (327.0)|<br>2.1 (53.34)|
|JCU-30E|30|5500|Single|100,000|63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-40E|40|5500|Single|100,000|63,000|17.88 (454.15)|3 (76.20)|
|JCU-50E|50|5500|Single|100,000|63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-65E|60|5500|Single|100000|63000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-80E|80|5500|Single|,<br>100,000|,<br>63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-100E|100|5500|Single|100,000|63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-125E|125|5500|Single|100,000|63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-150E|150|5500|Single|100000|63000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-175E|175|5500|Single|,<br>100,000|,<br>63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-200E|200|5500|Single|100,000|63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-250E|250|5500|Single|100,000|63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-300E|300|5500|Double|100,000|63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-350E|350|5500|Double|100,000|63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-400E|400|5500|Double|100,000|63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-450E|450|5500|Double|100,000|63,000|<br>17.88 (454.15)|<br>3 (76.20)|
|JCU-600E|600|5500|*|80,000|50,000|<br>28.81 (731.77)|<br>4 (101.60)|
|JCU-750E|750|5500|*|80,000|50,000|<br>28.81 (731.77)|<br>4 (101.60)|
|**8300V; E-Rated; Indoor/Enclosure**||||<br>||||
|JCZ-15E|15|8300|Single|80,000|50,000|15.51 (393.95)|2.1 (53.34)|
|JCZ-20E|20|8300|Single|80,000|50,000|<br>15.51 (393.95)|<br>2.1 (53.34)|
|JCZ-25E|25|8300|Single|80,000|50,000|<br>15.51 (393.95)|<br>2.1 (53.34)|
|JCZ-30E|30|8300|Single|80,000|50,000|<br>17.88 (454.15)|<br>3 (76.2)|
|JCZ-40E|40|8300|Single|80,000|50,000|<br>17.88 (454.15)|<br>3 (76.2)|
|JCZ-50E|50|8300|Single|80,000|50,000|<br>17.88 (454.15)|<br>3 (76.2)|
|JCZ-65E|65|8300|Single|80,000|50,000|<br>17.88 (454.15)|<br>3 (76.2)|
|JCZ-80E|80|8300|Single|80,000|50,000|<br>17.88 (454.15)|<br>3 (76.2)|
|JCZ-100E|100|8300|Single|80,000|50,000|<br>17.88 (454.15)|<br>3 (76.2)|
|JCZ-125E|125|8300|Single|80,000|50,000|<br>17.88 (454.15)|<br>3 (76.2)|
|JCZ-150E|150|8300|Single|80,000|50,000|<br>17.88 (454.15)|<br>3 (76.2)|
|JCZ-200E|200|8300|Double|80,000|50,000|<br>17.88 (454.15)|<br>3 (76.2)|
|JDZ-20E|20|8300|Single|80,000|50,000|<br>15.88 (403.2)|<br>3 (76.2)|
|JDZ-25E|25|8300|Single|80,000|50,000|15.88 (403.2)|3 (76.2)|
|JDZ-30E|30|8300|Single|80,000|50,000|15.88 (403.2)|3 (76.2)|
|JDZ-40E|40|8300|Single|80,000|50,000|<br>15.88 (403.2)|<br>3 (76.2)|
|JDZ-50E|50|8300|Single|80,000|50,000|<br>15.88 (403.2)|<br>3 (76.2)|
|JDZ-65E|65|8300|Single|80,000|50,000|<br>15.88 (403.2)|<br>3 (76.2)|
|JDZ-80E|80|8300|Double|80,000|50,000|<br>15.88 (403.2)|<br>3 (76.2)|
|JDZ-100E|100|8300|Double|80,000|50,000|<br>15.88 (403.2)|<br>3 (76.2)|
|JDZ-125E|125|8300|Double|80,000|50,000|<br>15.88 (403.2)|<br>3 (76.2)|
|Recommended fuseclips: see page 120 - 1A0065, 9078A67G04, A3354730<br>General Notes:||||<br>||||
1. All fuses are fitted with a striker pin which can be used for indication or tripping purposes.
2. The fuses are suitable for use either indoors or outdoors.
3. These fuses are interchangeable with corresponding fuses produced by most other leading North American manufacturers. Contact Bussmann for the latest product information on E-Rated fuses for transformer and feeder protection.
- *Bolt on mounting
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**104**
**Medium Voltage Fuses**
## **E-Rated Fuses: CL-14 & Bolt-In**
## **ECL055**
## **Specifications**
**Description:** E-rated medium voltage, current-limiting fuses for transformer and feeder protection.
**Construction:** Filament wound, glass epoxy fuse tube, with silica filler, and silver-plated copper terminals and endcaps containing a silver element in a double concentric helical configuration.
## **Catalog Numbers**
## **Ratings:**
|**Ratings:**|**Catalog Numbers**||
|---|---|---|
|**Ratings:**<br>Volts: — 5.5kV<br>Amps: — 10-900A<br>IR: — 63kA Sym. Max<br>**Agency Information:** Meets E requirements per ANSI<br>C37.46, Meets General Purpose requirements per ANSI<br>C37.40.<br>**Features and Benefits**<br>• Clip-lock and bolt-in style available in double and triple<br>barrel fuse designs for application flexibility<br>• The filament wound, glass epoxy fuse tube provides<br>moisture protection for the fuse. This makes Cooper<br>Bussmann medium voltage fuses suitable for both indoor<br>and outdoor application (outdoor applications require<br>installation inside an appropriate enclosure)<br>• Open fuse indication (indicator travel distance is 16mm)<br>easily integrates into automation schemes<br>• 50/60Hz operating frequency make these fuses applicable<br>world-wide|**Catalog**<br>**Amp**<br>**IR**<br>**# of**<br>**Numbers**<br>**Rating**<br>**Voltage**<br>**Max Sym.**<br>**Barrels**<br>ECL055-10E<br>10<br>5.5kV<br>63kA<br>1<br>ECL055-15E<br>15<br>–<br>ECL055-20E<br>20<br>–<br>ECL055-25E<br>25<br>–<br>ECL055-30E<br>30<br>–<br>ECL055-40E<br>40<br>–<br>ECL055-50E<br>50<br>–<br>ECL055-65E<br>65<br>–<br>ECL055-80E<br>80<br>–<br>ECL055-100E<br>100<br>–<br>ECL055-125E<br>125<br>–<br>ECL055-150E<br>150<br>–<br>ECL055-200E<br>200<br>–<br>ECL055-250E<br>250<br>–<br>ECL055-300E<br>300<br>–<br>2<br>ECL055-400E<br>400<br>–<br>ECL055-450E<br>450<br>–<br>ECL055-500E<br>500<br>–<br>ECL055-600E<br>600<br>–<br>ECL055-750E<br>750<br>–<br>3<br>ECL055-900E<br>900<br>–<br>1<br>~~2~~<br>3<br>63kA<br>~~re~~<br>~~a~~<br>~~rf|_|~~<br>~~re~~<br>~~a~~<br>~~a~~<br>~~ee~~<br>~~a~~<br>~~ee~~<br>~~:~~<br>~~a~~<br>~~a~~<br>~~ee~~<br>~~a~~<br>~~re~~<br>~~ee~~<br>~~ee~~<br>~~a~~<br>~~aa|~~|**Style**<br>Clip-Lock<br>Bolt-In<br>Clip-Lock<br>~~Clip-Lock~~<br>Bolt-In|
|**Typical Applications**|**Catalog Number Construction (Example)**||
|• 5.0kV Transformer Primary Protection|**Catalog Number**<br>**Voltage Rating**<br>**Amp Rating**||
|• 5.0kV Feeder Circuit Protection|ECL<br>055<br>500E||
|•5.0kV Voltage Switches|055 = 5.5 kV||
- 5.0kV Transformer Primary Protection
- 5.0kV Feeder Circuit Protection
- 5.0kV Voltage Switches
- 5.0kV Metal-enclosed Switchgear
## **Catalog Number Cross Reference**
## **Dimensions - in**
|**Bussmann**<br>**Catalog Numbers**|**Mersen**<br>**New Catalog #**|**Mersen**<br>**Old Catalog #**|
|---|---|---|
|ECL055-10E|A055C1DORO-10E<br>~~ee~~|225-007-937|
|ECL055-15E|A055C1DORO-15E<br>~~ee~~|225-007-938|
|ECL05515E<br>ECL055-20E|A055C1DORO15E<br>A055C1DORO-20E<br>~~ee~~|225007938<br>225-007-939|
|ECL055-25E|A055C1DORO-25E|225-007-940|
|ECL055-30E<br>ECL055-40E<br>~~Ce~~|A055C1DORO-30E<br>A055C1DORO-40E<br>~~Ce~~|225-007-941<br>225-007-942|
|ECL055-40E<br>ECL055-50E<br>ECL055-65E<br>~~Ce~~|A055C1DORO-40E<br>A055C1DORO-50E<br>A055C1DORO-65E<br>~~Ce~~|225-007-942<br>225-007-943<br>225-007-944|
|ECL055-65E<br>~~Ce~~|A055C1DORO-65E<br>~~Ce~~|225-007-944|
|ECL055-80E|A055C1DORO-80E|225-007-945|
|ECL05580E<br>ECL055-100E<br>~~——a~~|A055C1DORO80E<br>A055C1DORO-100E<br>~~——a~~|225007-945<br>225-007-946|
|ECL055-125E<br>~~——a~~|A055C1DORO-125E<br>~~——a~~|225-007-947|
|ECL055-150E<br>~~——a~~|A055C1DORO-150E<br>~~——a~~<br>~~Ld~~|225-007-948|
|ECL055-200E|A055C1DORO-200E<br>~~Ld~~|225-007-949|
|ECL055-250E|A055C1DORO-250E|225-007-950|
|ECL055-300E<br>ECL055-400E|A055C1DORO-300E<br>A055C1DORO-400E<br>~~a~~|225-007-951<br>225-007-952|
|ECL055400E<br>ECL055-450E<br>ECL055500E|A055C1DORO400E<br>A055C2DORO-450E<br>A055C2DORO500E<br>~~a~~|225007952<br>225-007-953<br>225007954|
|ECL055-500E<br>ECL055-600E<br>~~-——~~|A055C2DORO-500E<br>A055C2DORO-600E<br>~~a~~<br>~~-——~~|225-007-954<br>225-007-955<br>~~-——~~|
|ECL055-750E<br>ECL055-900E<br>~~-——~~|A055B3DORO-750E<br>A055B3DORO-900E<br>~~-——~~|A055X750E-4<br>A055X900E-4<br>~~-——~~|
## **Single Barrel**
## **Double Barrel**
## **Data Sheet: 9002**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**105**
**Medium Voltage Fuses**
## **E-Rated Fuses: CL-14 & Bolt-In**
## **ECL083**
## **Specifications**
**Description:** E-rated medium voltage, current-limiting fuses for transformer and feeder protection.
**Construction:** Filament wound, glass epoxy fuse tube, with silica filler, and silver-plated copper terminals and endcaps containing a silver element in a double concentric helical configuration.
## **Ratings:**
Volts: — 8.3kV
Amps: — 65-350A
IR: — 50kA
**Agency Information:** Meets E requirements per ANSI C37.46, Meets General Purpose requirements per ANSI C37.40.
## **Features and Benefits**
- Clip-lock and bolt-in style available in double and triple barrel fuse designs for application flexibility
- The filament wound, glass epoxy fuse tube provides moisture protection for the fuse. This makes Cooper Bussmann medium voltage fuses suitable for both indoor and outdoor application (outdoor applications require installation inside an appropriate enclosure)
- Open fuse indication (indicator travel distance is 16mm) easily integrates into automation schemes
- 50/60Hz operating frequency make these fuses applicable world-wide
## **Typical Applications**
- 8.0kV Transformer Primary Protection
- 8.0kV Feeder Circuit Protection
- 8.0kV Voltage Switches
- 8.0kV Metal-enclosed Switchgear
## **Catalog Number Construction (Example)**
**Catalog Number Voltage Rating Amp Rating** ECL 083 300E 083 = 8.3 kV
|PC|PC|PC|PC|PC|PC|PC|
|---|---|---|---|---|---|---|
|**Electrical Characteristics**<br>PC~~—~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~ft|~~|||||||
|**Part Number**<br>PC~~—~~<br>~~|~~<br>~~————~~|**Amps**<br>~~|~~<br>|**Volts**<br>~~|~~<br>|**IR Max**<br>**Sym.**<br>~~|~~<br>|**# of**<br>**Barrels**<br>~~ft~~<br>|**Figure**<br>**#**<br>~~ft|~~<br>|**Style**<br>~~|~~<br>|
|ECL083-65E<br>~~—~~<br>~~|~~<br>~~————~~|65<br>~~|~~<br>|8.3kV<br>~~|~~<br>|50kA<br>~~|~~<br>|1<br>~~ft~~<br>|1<br>~~ft |~~<br>|Clip-Lock<br>~~|~~<br>|
|ECL083-80E<br>~~————~~|80<br>|8.3kV<br>|50kA<br>|1<br>|1<br>|Clip-Lock<br>|
|ECL083-100E<br>~~————|~~|100<br>~~|~~|8.3kV<br>~~|~~|50kA<br>~~|~~|1<br>~~|~~|1<br>~~|~~|Clip-Lock<br>~~|~~|
|ECL083-125E<br>~~|~~|125<br>~~|~~|8.3kV<br>~~|~~|50kA<br>~~|~~|1<br>~~|~~|1<br>~~|~~|Clip-Lock<br>~~|~~|
|ECL083-150E<br>~~|~~<br>~~|~~|150<br>~~|~~<br>~~|~~|8.3kV<br>~~|~~<br>~~|~~|50kA<br>~~|~~<br>~~|~~|1<br>~~|~~<br>~~|~~|1<br>~~|~~<br>~~|~~|Clip-Lock<br>~~|~~<br>~~|~~|
|ECL083-175E<br>~~|~~|175<br>~~|~~|8.3kV<br>~~|~~|50kA<br>~~|~~|1<br>~~|~~|1<br>~~|~~|Clip-Lock<br>~~|~~|
|ECL083-200E<br>~~|~~<br>~~—~~|200<br>~~|~~<br>~~—~~|8.3kV<br>~~|~~<br>~~—~~|50kA<br>~~|~~<br>~~—~~|2<br>~~|~~<br>~~—~~|2<br>~~|~~<br>~~—~~|Clip-Lock<br>~~|~~<br>~~—~~|
|ECL083-250E<br>~~—~~|250<br>~~—~~|8.3kV<br>~~—~~|50kA<br>~~—~~|2<br>~~—~~|2<br>~~—~~|Clip-Lock<br>~~—~~|
|ECL083-300E<br>~~—~~<br>~~es~~|300<br>~~—~~|8.3kV<br>~~—~~|50kA<br>~~—~~|2<br>~~—~~|2<br>~~—~~|Clip-Lock<br>~~—~~|
|ECL083-350E<br>~~—~~<br>~~es~~|350<br>~~—~~|8.3kV<br>~~—~~|50kA<br>~~—~~|2<br>~~—~~|2<br>~~—~~|Clip-Lock<br>~~—~~|
## **Catalog Number Cross Reference**
|**Bussmann**<br>**Catalog Numbers**|**Mersen**<br>**New Catalog #**|**Mersen**<br>**Old Catalog #**|
|---|---|---|
|ECL083-65E|N/A|N/A|
|ECL083-80E|N/A|N/A|
|ECL083-100E|N/A|N/A|
|ECL083-125E|N/A|N/A|
|ECL083-150E|N/A|N/A|
|ECL083-175E|N/A|N/A|
|ECL083-200E|N/A|N/A|
|ECL083-250E|N/A|N/A|
|ECL083-300E|N/A|N/A|
|ECL083-350E|N/A|N/A|
## **Dimensions - in**
**Single Barrel**
## **Double Barrel**
**Data Sheet: 9007**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**106**
**Medium Voltage Fuses** ee:
## **E-Rated Fuses: CL-14**
## **ECL155**
## **Specifications**
**Description:** E-rated medium voltage, current-limiting fuses for transformer and feeder protection.
**Construction:** Filament wound, glass epoxy fuse tube, with silica filler, and silver-plated copper terminals and endcaps containing a silver element in a double concentric helical configuration.
## **Ratings:**
Volts: — 15.5kV
Amps: — 10-300A
IR: — 63kA Sym. (10-200A)
— 50kA Sym. (250-300A)
**Agency Information:** Meets E requirements per ANSI C37.46, Meets General Purpose requirements per ANSI C37.40.
## **Features and Benefits**
- Clip-lock double barrel fuse design assures positive installation
- The filament wound, glass epoxy fuse tube provides moisture protection for the fuse. This makes Cooper Bussmann medium voltage fuses suitable for both indoor and outdoor application (outdoor applications require installation inside an appropriate enclosure)
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Amp**<br>**Rating**|**Voltage**|**IR Voltage**<br>**Max Sym.**|**# of**<br>**Barrels**|**Style**|
|---|---|---|---|---|---|
|ECL155-10E|10|15.5kV|63KA|1|Clip-Lock|
|ECL155-15E|15|||||
|ECL155-20E|20|||||
|ECL155-25E|25|||||
|ECL155-30E|30|||||
|ECL155-40E|40|||~~1~~||
|ECL155-50E|50||~~63kA~~|~~1~~||
|ECL155-65E|65|15.5kV|~~63kA~~||Clip-Lock|
|ECL155-80E|80||||Clip|
|ECL155-100E|100|||||
|ECL155-125E|125|||||
|ECL155-150E|150|||2||
|ECL155-200E|200|||||
|ECL155-250E|250||50kA<br>50kA|2||
|ECL155-300E|300||50kA|||
- Open fuse indication (indicator travel distance is 16mm) easily integrates into automation schemes
- 50/60Hz operating frequency make these fuses applicable world-wide
## **Typical Applications**
**Catalog Number Construction (Example) Catalog Number Voltage Rating Amp Rating** ECL 155 300E 155 = 15.5 kV
- 15.0kV Transformer Primary Protection
- 15.0kV Feeder Circuit Protection
- 15.0kV Voltage Switches
- 15.0kV Metal-enclosed Switchgear
## **Dimensions - in**
## **Single Barrel** ~~[ti“‘i‘~~ OOCOC ~~CSC~~
## **Double Barrel**
## **Catalog Number Cross Reference**
|**Bussmann**<br>**Catalog Numbers**|**Mersen**<br>**New Catalog #**|**Mersen**<br>**Old Catalog #**|
|---|---|---|
|**Catalog Numbers**<br>ECL155-10E|**New Catalog #**<br>A155C1DORO-10E<br>~~ee~~|**Old Catalog #**<br>225-007-967|
|ECL155-15E|A155C1DORO-15E<br>~~ee~~<br>~~-_———_~~|225-007-968|
|ECL155-20E|A155C1DORO-20E<br>~~-_———_~~|225-007-969|
|ECL155-25E|A155C1DORO-25E<br>~~-_———_~~<br>~~——~~|225-007-970|
|ECL155-30E<br>~~ET~~|A155C1DORO-30E<br>~~——~~<br>~~ET~~|225-007-971|
|ECL155-40E<br>~~ET~~|A155C1DORO-40E<br>~~——~~<br>~~ET~~|225-007-972|
|ECL155-50E<br>ECL155-65E<br>ECL15580E<br>~~ET~~|A155C1DORO-50E<br>A155C1DORO-65E<br>A155C1DORO80E<br>~~——~~<br>~~ET~~<br>~~-——_~~|225-007-973<br>225-007-974|
|ECL155-80E<br>ECL155-100E<br>ECL155-125E|A155C1DORO-80E<br>A155C1DORO-100E<br>A155C2DORO-125E<br>~~-——_~~|225-007-975<br>225-007-976<br>225-007-977|
|ECL155-125E|A155C2DORO-125E|225-007-977|
|ECL155-150E|A155C3DORO-150E|225-007-978|
|ECL155150E<br>ECL155-200E|A155C3DORO150E<br>A155C3DORO-200E|225007978<br>225-007-979|
|ECL155-250E|A155C3DORO-250E|225-007-980|
|ECL155-300E|A155C3DORO-300E|225-007-981|
**==> picture [72 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data Sheet: 9004<br>**----- End of picture text -----**<br>
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**107**
**Medium Voltage Fuses**
## **E-Rated Fuses for Potential & Small Power Transformers**
## **AB, AD, AM and CAV**
## **Ratings:**
Volts: — 5.5-38kV Amps: — 0.5-15A IR: — 40kA-80kA Sym.
- See Catalog Numbers table for details
## **Features and Benefits**
- Sized for retrofitting in existing hardware
## **Specifications**
**Description:** Indicating and non-indicating E-Rated medium voltage, current-limiting fuses for potential and small power transformers.
**Dimensions:** See Catalog Numbers table.
Dimension Illustration on the following page
- Space saving size
## **Typical Applications**
- Primary protection of medium voltage potential transformers
- Primary protection of small medium voltage service transformers
- Primary protection of small medium voltage control transformers
## **Catalog Numbers: E-Rated PT Fuses, Indicating & Non-Indicating**
## 3.6kV; E-Rated PT Fuse; Non-indicating
|3.6kV; E-Rated PT Fuse; Non-indicating||
|---|---|
|Catalog<br>Amp<br>Rated<br>Dimensions|Spare Parts|
|Number<br>Rating<br>Voltage<br>IR RMS Sym.<br>Length<br>Diameter<br>Clip Centers|(Clips)|
|3.6CAV2<br>2<br>3.6kV<br>50kA<br>8.66 (220)<br>1.63 (41.3)<br>7.46 (189.48)|1A0835|
|3.6ABWNA3.15<br>3.15<br>3.6kV<br>50kA<br>5.6 (142.2)<br>1 (25.4)<br>4.42 (112.2)|A3354705|
|3.6ABWNA6.3<br>3.15<br>3.6kV<br>50kA<br>5.6 (142.2)<br>1 (25.4)<br>4.42 (112.2)|A3354705|
|3.6ABCNA3.15<br>3.15<br>3.6kV<br>50kA<br>7.69 (195.3)<br>1 (25.4)<br>6.51 (165.3)|A3354705|
|3.6ABCNA6.3<br>6.3<br>3.6kV<br>50kA<br>7.69 (195.3)<br>1 (25.4)<br>6.51 (165.3)|A3354705|
|3.6ABCNA10<br>10<br>3.6kV<br>50kA<br>7.69 (195.3)<br>1 (25.4)<br>6.51 (165.3)|A3354705|
|5.5kV; E-Rated PT Fuse; Indicating & Non-indicating||
|Catalog<br>Amp<br>Rated<br>Dimensions|Spare Parts|
|Number<br>Rating<br>Voltage<br>IR RMS Sym.<br>Length<br>Diameter<br>Clip Centers<br>~~Po~~|(Clips)|
|5.5CAVH0.5E<br>0.5<br>5.5kV<br>63kA<br>7.375 (187.3)<br>1.63 (41.3)<br>6.18 (156.84)<br>~~CG~~|1A0835|
|5.5CAVH1E<br>1<br>5.5kV<br>63kA<br>7.375 (187.3)<br>1.63 (41.3)<br>6.18 (156.84)<br>~~CG~~|1A0835|
|5.5CAVH2E<br>2<br>5.5kV<br>63kA<br>7.375 (187.3)<br>1.63 (41.3)<br>6.18 (156.84)<br>~~CG~~|1A0835|
|5.5CAV15E<br>15<br>5.5kV<br>63kA<br>7.375 (187.3)<br>1.63 (41.3)<br>6.18 (156.84)<br>~~CG~~|1A0835|
|5.5ABWNA0.5E<br>0.5<br>5.5kV<br>50kA<br>5.6 (142.2)<br>1 (25.4)<br>4.42 (112.2)<br>~~CG~~|A3354705|
|5.5ABWNA1E<br>1<br>5.5kV<br>50kA<br>5.6 (142.2)<br>1 (25.4)<br>4.42 (112.2)<br>~~CG~~|A3354705|
|5.5ABWNA2E<br>2<br>5.5kV<br>50kA<br>5.6 (142.2)<br>1 (25.4)<br>4.42 (112.2)<br>~~CG~~|A3354705|
|5.5ABWNA3E<br>3<br>5.5kV<br>50kA<br>5.6 (142.2)<br>1 (25.4)<br>4.42 (112.2)<br>~~CG~~|A3354705|
|5.5ABWNA5E<br>5<br>5.5kV<br>50kA<br>5.6 (142.2)<br>1 (25.4)<br>4.42 (112.2)<br>~~CG~~|A3354705|
|5.5AMWNA0.5E<br>0.5<br>5.5kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>~~CG~~|1A1837|
|5.5AMWNA1.0E<br>1<br>5.5kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>~~CG~~|1A1837|
|5.5AMWNA2.0E<br>2<br>5.5kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>~~CG~~|1A1837|
|5.5AMWNA3.0E<br>3<br>5.5kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>~~CG~~|1A1837|
|5.5AMWNA4.0E<br>4<br>5.5kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>~~CG~~|1A1837|
|5.5AMWNA5.0E<br>5<br>5.5kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>~~eG~~|1A1837|
|Type CAVH are fitted with a striker pin for indication||
|7.2kV; E-Rated PT Fuse; Non-indicating||
|Catalog<br>Amp<br>Rated<br>Dimensions<br>Number<br>Rating<br>Voltage<br>IR RMS Sym.<br>Length<br>Diameter<br>Clip Centers<br>7.2CAV2<br>2<br>7.2kV<br>63kA<br>8.66 (220)<br>1.63 (41.3)<br>7.46 (189.48)<br>7.2CAV4<br>4<br>7.2kV<br>63kA<br>8.66 (220)<br>1.63 (41.3)<br>7.46 (189.48)<br>7.2CAV6<br>6<br>7.2kV<br>63kA<br>8.66 (220)<br>1.63 (41.3)<br>7.46 (189.48)<br>7.2CAV10<br>10<br>7.2kV<br>63kA<br>8.66 (220)<br>1.63 (41.3)<br>7.46 (189.48)<br>7.2ABWNA3.15<br>3.15<br>7.2kV<br>45kA<br>5.6 (142.2)<br>1 (25.4)<br>4.42 (112.2)<br>7.2ABWNA6.3<br>6.3<br>7.2kV<br>45kA<br>5.6 (142.2)<br>1 (25.4)<br>4.42 (112.2)<br>7.2ABCNA3.15<br>3.15<br>7.2kV<br>45kA<br>7.69 (195.3)<br>1 (25.4)<br>6.51 (165.3)<br>7.2ABCNA6.3<br>6.3<br>7.2kV<br>45kA<br>7.69 (195.3)<br>1 (25.4)<br>6.51 (165.3)<br>7.2AMWNA0.5E<br>0.5<br>7.2kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>7.2AMWNA1.0E<br>1<br>7.2kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>7.2AMWNA2.0E<br>2<br>7.2kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>7.2AMWNA3.0E<br>3<br>7.2kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>7.2AMWNA4.0E<br>4<br>7.2kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>7.2AMWNA5.0E<br>5<br>7.2kV<br>50kA<br>5.6 (142.2)<br>0.81 (20.6)<br>4.79 (121.6)<br>~~Pe~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa GG~~<br>~~a~~<br>~~Qa ~~~~**GG**~~<br>~~a~~<br>~~Qa~~<br>~~GD~~<br>~~GG~~|Spare Parts<br>(Clips)<br>1A0835<br>1A0835<br>1A0835<br>1A0835<br>A3354705<br>A3354705<br>A3354705<br>A3354705<br>1A1837<br>1A1837<br>1A1837<br>1A1837<br>1A1837<br>1A1837|
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**108**
**Medium Voltage Fuses**
## **E-Rated Fuses for Potential & Small Power Transformers**
## **Dimension Illustration**
**==> picture [210 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
Length<br>Clip Centers<br>Diameter<br>**----- End of picture text -----**<br>
## **Catalog Numbers: E-Rated PT Fuses, Indicating & Non-Indicating**
## 12kV; E-Rated PT Fuse; Non-indicating
|Catalog<br>Number|Amp<br>Rating|Rated<br>Voltage|IR RMS Sym.|Dimensions|Dimensions|Dimensions|Spare Parts<br>(Clips)|
|---|---|---|---|---|---|---|---|
|||||Length|Diameter|Clip Centers||
|12CAV2|2|12kV|<br>40kA|8.66 (220)|1.63 (41.3)|7.46 (189.48)|1A0835|
|12ABCNA3.15|3.15|12kV|45kA|7.69 (195.3)|1 (25.4)|6.51 (165.3)|A3354705|
## 15.5kV; E-Rated PT Fuse; Indicating & Non-indicating
|Catalog<br>Number|Amp<br>Rating|Rated<br>Voltage|IR RMS Sym.|Dimensions|Dimensions|Dimensions|Spare Parts<br>(Clips)|
|---|---|---|---|---|---|---|---|
|||||Length|Diameter|Clip Centers||
|15.5CAV(H)0.5E|0.5|15.5kV|<br>80kA|12.87 (326.9|1.63 (41.3)|1.2 (30.5)|1A0835|
|15.5CAV(H)1E|1|15.5kV|80kA|12.87 (326.9|1.63 (41.3)|1.2 (30.5)|1A0835|
|15.5CAV(H)2E|2|15.5kV|80kA|12.87 (326.9|1.63 (41.3)|1.2 (30.5)|1A0835|
|15.5CAV3E|3|15.5kV|80kA|12.87 (326.9|1.63 (41.3)|1.2 (30.5)|1A0835|
|15.5CAV5E|5|15.5kV|80kA|<br>12.87 (326.9|<br>1.63 (41.3)|<br>1.2 (30.5)|1A0835|
|15.5CAV7E|7|15.5kV|80kA|<br>12.87 (326.9|<br>1.63 (41.3)|<br>1.2 (30.5)|1A0835|
|Type CAVH are fitted with a striker pin for indication||||||||
## 17.5kV; E-Rated PT Fuse; Non-indicating
|Catalog<br>Number|Amp<br>Rating|Rated<br>Voltage|IR RMS Sym.|Dimensions|Dimensions|Dimensions|Spare Parts<br>(Clips)|
|---|---|---|---|---|---|---|---|
|||||Length|Diameter|Clip Centers||
|17.5CAV2|2|17.5kV|<br>40kA|8.66 (220)|1.63 (41.3)|7.46 (189.48)|1A0835|
|17.5CAV4|4|17.5kV|40kA|8.66 (220)|1.63 (41.3)|7.46 (189.48)|1A0835|
|17.5CAV6|6|17.5kV|40kA|8.66 (220)|1.63 (41.3)|7.46 (189.48)|1A0835|
|17.5CAV10|10|17.5kV|40kA|8.66 (220)|1.63 (41.3)|7.46 (189.48)|1A0835|
|17.5ABGNA3.15|3.15|17.5kV|35kA|14.13 (358.9)|1 (25.4)|12.95 (328.9)|A3354705|
## 24kV; E-Rated PT Fuse; Non-indicating
|Catalog<br>Number|Amp<br>Rating|Rated<br>Voltage|IR RMS Sym.|Dimensions|Dimensions|Dimensions|Spare Parts<br>(Clips)|
|---|---|---|---|---|---|---|---|
|||||Length|Diameter|Clip Centers||
|24CAV2|2|24kV|<br>40kA|13.39 (340.1)|1.63 (41.3)|12.19 (309.62)|1A0835|
|24CAV3|3|24kV|40kA|<br>13.39 (340.1)|<br>1.63 (41.3)|<br>12.19 (309.62)|1A0835|
|24CAV4|4|24kV|40kA|<br>13.39 (340.1)|<br>1.63 (41.3)|<br>12.19 (309.62)|1A0835|
|24ABGNA3.15|3.15|24kV|25kA|<br>14.13 (358.9)|<br>1 (25.4)|<br>12.95 (328.9)|A3354705|
## 36kV; E-Rated PT Fuse; Non-indicating
|Catalog<br>Number|Amp<br>Rating|Rated<br>Voltage|IR RMS Sym.|Dimensions|Dimensions|Dimensions|Spare Parts<br>(Clips)|
|---|---|---|---|---|---|---|---|
|||||Length|Diameter|Clip Centers||
|36CAV2|2|36kV|<br>40kA|17.32 (439.9)|1.63 (41.3)|16.12 (409.44)|1A0835|
|36CAV4|4|36kV|40kA|<br>17.32 (439.9)|<br>1.63 (41.3)|<br>16.12 (409.44)|1A0835|
|36ABGNA3.15|3.15|36kV|31.5kA|<br>14.13 (358.9)|<br>1 (25.4)|<br>12.95 (328.9)|A3354705|
|38kV; E-Rated PT Fuse; Indicating & Non-indicating||||||||
|Catalog<br>Number|Amp<br>Rating|Rated<br>Voltage|IR RMS Sym.|Dimensions|||Spare Parts<br>(Clips)|
|||||Length|Diameter|Clip Centers||
|38CAVH0.5E|0.5|38kV|<br>40kA|17.32 (439.9)|1.63 (41.3)|16.12 (409.44)|1A0835|
|38CAVH1E|1|38kV|40kA|<br>17.32 (439.9)|<br>1.63 (41.3)|<br>16.12 (409.44)|1A0835|
|38CAVH2E|2|38kV|40kA|<br>17.32 (439.9)|<br>1.63 (41.3)|<br>16.12 (409.44)|1A0835|
|38CAV4E|4|38kV|40kA|<br>17.32 (439.9)|<br>1.63 (41.3)|<br>16.12 (409.44)|1A0835|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**109**
**Medium Voltage Fuses**
## **E-Rated, PT Fuses for Potential & Small Power Transformers**
## **JCD, JCW, JCQ, JCI & JCT**
## **Specifications**
**Description:** Indicating and nonindicating E-rated medium voltage, current-limiting fuses for potential and small power transformers.
**Dimensions:** See Catalog Numbers table.
## **Features and Benefits**
- Sized for retrofitting in existing hardware
- Space saving size
## **Typical Applications**
- Primary protection of medium voltage potential transformers
- Primary protection of small medium voltage service transformers
- Primary protection of small medium voltage control transformers
**Construction:** Plated ferrules.
**Ratings:**
Volts: — 2.4-15.5kV (See Catalog Numbers table for details)
Amps: —[1] ⁄2-10A IR: — 25-80kA Sym — 40-130kA ASYM
- See Catalog Numbers table for details
|2.4kV; E-Rated PT Fuse; Non-indicating|
|---|
|Catalog<br>Amp<br>Rated<br>Dimensions<br>Spare Parts<br>Number<br>Rating<br>Voltage<br>IR RMS Sym.<br>Length<br>Diameter<br>Clip Centers<br>(Clips)<br>JCD-1-2E<br>0.5<br>2.4kV<br>63kA<br>4.49 (114)<br>0.8 (20)<br>3.86 (98)<br>1A1837<br>JCD-1E<br>1<br>2.4kV<br>40kA<br>4.49 (114)<br>0.8 (20)<br>3.86 (98)<br>1A1837<br>JCD-2E<br>2<br>2.4kV<br>40kA<br>4.49 (114)<br>0.8 (20)<br>3.86 (98)<br>1A1837<br>JCD-5E<br>5<br>2.4kV<br>25kA<br>4.49 (114)<br>0.8 (20)<br>3.86 (98)<br>1A1837<br>~~==~~|
|2.4/5.5kV; E-Rated PT Fuse; Non-indicating|
|Catalog<br>Amp<br>Rated<br>Dimensions<br>Spare Parts<br>Number<br>Rating<br>Voltage<br>IR RMS Sym.<br>Length<br>Diameter<br>Clip Centers<br>(Clips)<br>JCW-1/2E<br>0.5<br>2.4kV/5.5kV<br>40kA<br>7.31 (185)<br>1.56 (39.7)<br>5.93 (150.6)<br>1A0835<br>JCW-1E<br>1<br>2.4kV/5.5kV<br>40kA<br>7.31 (185)<br>1.56 (39.7)<br>5.93 (150.6)<br>1A0835<br>JCW-2E<br>2<br>2.4kV/5.5kV<br>40kA<br>7.31 (185)<br>1.56 (39.7)<br>5.93 (150.6)<br>1A0835<br>JCW-3E<br>3<br>2.4kV/5.5kV<br>40kA<br>7.31 (185)<br>1.56 (39.7)<br>5.93 (150.6)<br>1A0835<br>JCW-4E<br>4<br>2.4kV/5.5kV<br>40kA<br>7.31 (185)<br>1.56 (39.7)<br>5.93 (150.6)<br>1A0835<br>JCW-5E<br>5<br>2.4kV/5.5kV<br>40kA<br>7.31 (185)<br>1.56 (39.7)<br>5.93 (150.6)<br>1A0835<br>~~eee~~|
|5.5kV; E-Rated PT Fuse; Indicating|
|Catalog<br>Amp<br>Rated<br>Dimensions<br>Spare Parts<br>Number<br>Rating<br>Voltage<br>IR RMS Sym.<br>Length<br>Diameter<br>Clip Centers<br>(Clips)<br>JCQ-3E<br>3<br>5.5kV<br>130kA<br>9.5 (241.3)<br>1.6 (40.6)<br>8.12 (206)<br>1A0835<br>JCQ-5E<br>5<br>5.5kV<br>130kA<br>9.5 (241.3)<br>1.6 (40.6)<br>8.12 (206)<br>1A0835<br>JCQ-10E<br>10<br>5.5kV<br>130kA<br>9.5 (241.3)<br>1.6 (40.6)<br>8.12 (206)<br>1A0835<br>~~——————~~|
|8.3kV; E-Rated PT Fuse; Indicating|
|Catalog<br>Amp<br>Rated<br>Dimensions<br>Spare Parts<br>Number<br>Rating<br>Voltage<br>IR RMS Sym.<br>Length<br>Diameter<br>Clip Centers<br>(Clips)<br>JCI-3E<br>3<br>8.3kV<br>80kA<br>12.88 (327)<br>1.6 (40.6)<br>11.5 (292)<br>1A0835<br>JCI-5E<br>5<br>8.3kV<br>80kA<br>12.88 (327)<br>1.6 (40.6)<br>11.5 (292)<br>1A0835<br>JCI-10E<br>10<br>8.3kV<br>80kA<br>12.88 (327)<br>1.6 (40.6)<br>11.5 (292)<br>1A0835<br>~~ee~~<br>~~ee~~<br>~~ee~~|
|15.5kV; E-Rated PT Fuse; Indicating|
|Catalog<br>Amp<br>Rated<br>Dimensions<br>Spare Parts<br>Number<br>Rating<br>Voltage<br>IR RMS Sym.<br>Length<br>Diameter<br>Clip Centers<br>(Clips)<br>JCT-3E<br>3<br>15.5kV<br>80kA<br>17.5 (444.5)<br>1.6 (40.6)<br>16.12 (409.4)<br>1A0835<br>JCT-5E<br>5<br>15.5kV<br>80kA<br>17.5 (444.5)<br>1.6 (40.6)<br>16.12 (409.4)<br>1A0835<br>JCT-10E<br>10<br>15.5kV<br>80kA<br>17.5 (444.5)<br>1.6 (40.6)<br>16.12 (409.4)<br>1A0835<br>~~—————~~|
|**Data Sheet: 6002**|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**110**
**Medium Voltage Fuses**
## **PT Fuses**
## **HVA, HVB, HVJ, HVL, HVR, HVT, HVU, HVW & HVX**
## **Specifications**
**Test Specifications Basic Catalog Numbers Load / Opening Time** HVA, HVB, HVJ, HVL 110% / 4 Hours (min) 135% / 1 Hour (max) HVR, HVT, HVU, HVW, HVX 100% / 4 Hours (min) 150% / 1 Hour (max) ~~—+ ——~~
**Description:** Medium voltage, non-time delay, fast-acting fuses.
**Dimensions:** See Basic Catalog Numbers table.
## **Ratings:**
Volts: — 1-10kV (See Basic Catalog Numbers table) Amps: —[1] ⁄16-10A (See Basic Catalog Numbers table)
## **Features and Benefits**
- Physical size varies with electrical rating of fuse to prevent over-fusing.
- Space saving size.
## **Typical Applications**
- Medium Voltage Instrument Protection
- Medium Voltage Circuit Protection
## **Fuse blocks:** 4528, 4529
## **Voltage Rating:** 1000 to 10,000V
|**Basic Catalog**|**Fuse Block**|**Fuse Clip**|
|---|---|---|
|**Numbers**|**Catalog Number**|**Catalog Number**|
|HVA, HVR|4528|5960|
|HVB, HVT<br>HVJ, HVU<br>HVL, HVX|4529<br>N/A<br>N/A|5960<br>4180<br>4180|
|Use #8 screws on blocks 4528 and 4529.|||
## **Basic**
|**Basic**||||||
|---|---|---|---|---|---|
|**Catalog**<br>**Number**|**kV**|**Amp Ratings**|**Maximum S.C.**|**Dimensions - in(mm)**||
|||||**Diameter**|**Length**|
|HVA|1|**Amp Ratings**<br>1⁄16,1⁄10,1⁄8,2⁄10,1⁄4,3⁄10,3⁄8,1⁄2,<br>3⁄4, 1, 11⁄2, 2, 3, 4, 6, 10|20kW DC/30kVA AC|0.41 (10.4)|**Length**<br>3 (76.1)|
|HVB|2.5|1⁄2,3⁄4, 1, 11⁄2, 2, 3|20kW DC/30kVA AC|0.41 (10.4)|4.5 (114.2)|
|HVJ|5|1⁄16,1⁄8,1⁄4,1⁄2,3⁄4, 11⁄2, 2, 4, 6, 10|20kW DC/30kVA AC|0.81 (20.6)|5 (126.9)|
|HVL|10|1⁄16,1⁄8,1⁄4,1⁄2, 1, 11⁄2, 2, 3|20kW DC/30kVA AC|0.81 (20.6)|10 (254)|
|HVR|1|1⁄2, 1, 2, 3, 4, 5|kVA-500 AC only|0.41 (10.4)|3 (76.2)|
|HVW|1.2|1, 2, 3, 4, 5, 8|kVA-12,000 AC only|0.41 (10.4)|2.25 (57.1)|
|HVT|2.5|1⁄2, 1, 2, 3, 5|kVA-1250 AC only|0.41 (10.4)|4.5 (114.2)|
|HVU|5|1⁄2, 1, 2, 3, 4, 5|kVA-2500 AC only|0.81 (20.6)|5 (126.9)|
|HVX|10|1⁄2, 1, 3, 5|kVA-5,000 AC only|0.41 (10.4)|10.0 (253.8)|
## **Catalog Number Build-A-Code**
Basic Catalog Number Amps _ _ _ _ _ _ _ _
**Data Sheet: 6003**
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**111**
**Medium Voltage Fuses**
## **R-Rated Fuses for Motor Circuit Protection**
**JCG, JCH, JCK, JCK-A, JCK-B, JCL, JCL-A, JCL-B, JCR-A, & JCR-B**
## **Specifications**
**Description:** Indoor/enclosure R-Rated medium voltage, current-limiting fuses for motor circuit protection.
**Dimensions:** See Dimensions illustrations.
## **Ratings:**
**Agency Information:** UL Recognized: 2540Vac — JCK, JCK-A, 5080Vac — JCL, JCL-A, UL Recognized (Guide #MSSS2, File #E96676).
## **Features and Benefits**
- Physically dimensioned for retrofitting in existing hardware
- Open fuse indicator for ease in troubleshooting
- Available with optional Cutler Hammer[®] hookeye for ease of insertion and removal
- Classified as back-up fuses for current-limited protection of medium voltage motor controllers
## **Typical Applications**
- Medium Voltage Motor Controllers
Volts: — 2.4-7.2kV (See Catalog Numbers table for details)
- Amps: — 25-450A (See Catalog Numbers table for details) IR: — 50kA Sym
- 80kA ASYM
- See Catalog Numbers table for details
## **Dimensions - mm (in)**
**==> picture [338 x 80] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 1 INDICATOR<br>Showing Fuse is Open<br>0.38"<br>(9.5mm)<br>C INDICATOR<br>L y A |} Showing Fuse ®<br>is Open B<br>— — _<br>**----- End of picture text -----**<br>
**==> picture [38 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 2<br>**----- End of picture text -----**<br>
**Figure 3**
## **Data Sheet 6001**
For product data sheets, visit For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**112**
**Medium Voltage Fuses**
## **R-Rated Fuses for Motor Circuit Protection**
## **Catalog Numbers: R-Rated; Indoor/Enclosure**
|**Catalog**<br>**Numbers**|**Amp**<br>**Ratings**|**Maximum**<br>**Design Voltage**|**Dimensions - in(mm)***|**Dimensions - in(mm)***|**Dimensions - in(mm)***|**Construction**|**Max Int. Cap.**<br>**Amps (Asym.)**|**Amps**<br>**(Sym.)**|**Min Int. Cap.**<br>**Amps (Sym.)**|
|---|---|---|---|---|---|---|---|---|---|
||||**A**|**B**|**C**|||||
|<br> <br><br> <br>**2400V(See Figure 1)**||||||||||
|JCK-2R|70|2540|11.24 (285.5)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|165|
|JCK-3R|100|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|220|
|JCK-4R|130|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|320|
|JCK-5R|150|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|410|
|JCK-6R|170|2540|11.24 (285.5)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|480|
|JCK-9R|200|2540|11.24(285.5)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|720|
|JCK-12R|230|2540|11.24 (285.5)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|970|
|JCK-18R|390|2540|<br>11.24(285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Double|80,000|50,000|1,430|
|JCK-24R|450|2540|11.24 (285.5)|3.0 (76.2)|3.0 (76.2)|Double|80,000|50,000|1,880|
|**2400V — With Westinghouse Ampguard Hookeye (See Figure 1)**||||||||||
|JCK-A-2R|70|2540|11.24 (285.5)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|165|
|JCK-A-3R|100|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|220|
|JCK-A-4R|130|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|320|
|JCK-A-5R|150|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|410|
|JCK-A-6R|170|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|480|
|JCK-A-9R|200|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|720|
|JCK-A-12R|230|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|970|
|JCK-A-18R|390|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Double|80,000|50,000|1,430|
|JCK-A-24R|450|2540|<br>11.24 (285.5)|<br>3.0 (76.2)|<br>3.0 (76.2)|Double|80,000|50,000|1,880|
|<br> <br> <br><br><br><br>**2400V — Bolt-On(See Figures 2 & 3)**||||||||||
|JCK-B-30|25|2540|14.18(360.2)|12.81(325.4)|-|Single|80,000|50,000|90|
|JCK-B-2R|70|2540|14.18 (360.2)|12.81 (325.4)|-|Single|80,000|50,000|170|
|JCK-B-3R|100|2540|<br>14.18 (360.2)|<br>12.81(325.4)|-|Single|80,000|50,000|245|
|JCK-B-4R|130|2540|14.18 (360.2)|12.81 (325.4)|-|Single|80,000|50,000|340|
|JCK-B-5R|150|2540|14.18 (360.2)|12.81 (325.4)|-|Single|80,000|50,000|430|
|JCK-B-6R|170|2540|<br>14.18 (360.2)|<br>12.81 (325.4)|-|Single|80,000|50,000|500|
|JCK-B-9R|200|2540|<br>14.18 (360.2)|<br>12.81 (325.4)|-|Single|80,000|50,000|1,000|
|JCK-B-12R|230|2540|<br>14.18 (360.2)|<br>12.81 (325.4)|-|Single|80,000|50,000|1,250|
|JCK-B-18R|390|2540|<br>14.18 (360.2)|<br>12.81 (325.4)|3.56 (90.4)|Double|80,000|50,000|1,700|
|JCK-B-24R|450|2540|<br>14.18 (360.2)|<br>12.81 (325.4)|<br>3.56 (90.4)|Double|80,000|50,000|1,210|
|<br> <br> <br>**2400V— Hermetically Sealed, For Use with Ampguard Motor Starters (See Figure 1)**||||||||||
|JCH-30|<br>25|<br>2540|<br>10.81 (275.6)|<br>3.0 (76.2)|<br>3.0 (76.2)|<br>Single|<br>80,000|<br>50,000|90|
|JCH-2R|70|2540|10.81 (275.6)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|170|
|JCH-3R|100|2540|<br>10.81 (275.6)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|245|
|JCH-4R|130|2540|<br>10.81 (275.6)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|340|
|JCH-5R|150|2540|<br>10.81 (275.6)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|430|
|JCH-6R|170|2540|<br>10.81 (275.6)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|500|
|JCH-9R|200|2540|<br>10.81 (275.6)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|1,000|
|JCH-12R|230|2540|<br>10.81 (275.6)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|1,250|
|JCH-18R|390|2540|<br>10.81 (275.6)|<br>3.0 (76.2)|<br>3.0 (76.2)|Double|80,000|50,000|1,700|
|JCH-24R|450|2540|<br>10.81 (275.6)|<br>3.0 (76.2)|<br>3.0 (76.2)|Double|80,000|50,000|2,100|
|**4800V (See Figure 1)**||||||||||
|<br>JCL-2R|<br>70|<br>5080|15.76(400.3)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|165|
|JCL-3R|100|5080|15.76(400.3)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|220|
|JCL-4R|130|5080|15.76 (400.3)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|320|
|JCL-5R|150|5080|15.76 (400.3)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|410|
|JCL-6R|170|5080|15.76 (400.3)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|480|
|JCL-9R|200|5080|<br>15.76 (400.3)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|720|
|JCL-12R|230|5080|<br>15.76 (400.3)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|970|
|JCL-18R|390|5080|15.76 (400.3)|3.0 (76.2)|3.0 (76.2)|Double|80,000|50,000|1,430|
|JCL-24R|450|5080|15.76 (400.3)|3.0 (76.2)|3.0 (76.2)|Double|80,000|50,000|1,880|
• See previous page Figure 2 for single construction and Figure 3 for double construction information. Recommended fuseclips: see page 120 - 1A0065, A3354730, 9078A67G04.
**Data Sheet: 6001**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**113**
**Medium Voltage Fuses**
## **R-Rated Fuses for Motor Circuit Protection**
## **Catalog Numbers: R-Rated; Indoor/Enclosure**
|**Catalog**<br>**Numbers**|**Amp**<br>**Ratings**|**Maximum**<br>**Design Voltage**|**Dimensions - in(mm)**|**Dimensions - in(mm)**|**Dimensions - in(mm)**|**Construction**|**Max Int. Cap.**<br>**Amps (Asym.**|**Amps**<br>**(Sym.)**|**Min Int. Cap.**<br>**Amps (Sym.)**|
|---|---|---|---|---|---|---|---|---|---|
||||**A**|**B**|**C**|||||
|**4800V — With Westinghouse **|||**Ampguard Hookeye (See Figure 1)**|||||||
|JCL-A-2R|70|5080|15.76(400.3)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|165|
|JCL-A-3R|100|5080|15.76 (400.3)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|220|
|JCL-A-4R|130|5080|15.76(400.3)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|320|
|JCL-A-5R|150|5080|15.76(400.3)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|410|
|JCL-A-6R|170|5080|15.76(400.3)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|480|
|JCL-A-9R|200|5080|15.76(400.3)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|720|
|JCL-A-12R|230|5080|15.76 (400.3)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|970|
|JCL-A-18R|390|5080|15.76 (400.3)|3.0 (76.2)|3.0 (76.2)|Double|80,000|50,000|1,430|
|JCL-A-24R|450|5080|15.76(400.3)|3.0(76.2)|3.0(76.2)|Double|80,000|50,000|1,880|
|**4800V — Bolt-On (See Figures 2 & 3)**||||||||||
|JCL-B-30|30|5080|19.25(488.9)|17.88(454.1)|-|Single|80,000|50,000|95|
|JCL-B-2R|70|5080|19.25(488.9)|17.88(454.1)|-|Single|80,000|50,000|180|
|JCL-B-3R|100|5080|19.25(488.9)|17.88(454.1)|-|Single|80,000|50,000|270|
|JCL-B-4R|130|5080|19.25(488.9)|17.88(454.1)|-|Single|80,000|50,000|350|
|JCL-B-5R|150|5080|19.25(488.9)|17.88(454.1)|-|Single|80,000|50,000|450|
|JCL-B-6R|170|5080|19.25(488.9)|17.88(454.1)|-|Single|80,000|50,000|540|
|JCL-B-9R|200|5080|19.25 (488.9)|17.88 (454.1)|-|Single|80,000|50,000|700|
|JCL-B-12R|230|5080|19.25 (488.9)|17.88 (454.1)|-|Single|80,000|50,000|1,000|
|JCL-B-18R|390|5080|<br>19.25(488.9)|<br>17.88(454.1)|3.31(84.1)|Double|80,000|50,000|1,450|
|JCL-B-24R|450|5080|19.25(488.9)|17.88(454.1)|3.31(84.1)|Double|80,000|50,000|2,000|
|**4800V— Hermetically Sealed, For Use with Ampguard Motor Starters (See Figure 1)**||||||||||
|JCG-30|<br>30|<br>5080|<br>15.91 (404.1)|<br>3.0 (76.2)|<br>3.0 (76.2)|<br>Single|<br>80,000|<br>50,000|95|
|JCG-2R|70|5080|<br>15.91 (404.1)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|180|
|JCG-3R|100|5080|<br>15.91 (404.1)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|270|
|JCG-4R|130|5080|<br>15.91 (404.1)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|350|
|JCG-5R|150|5080|<br>15.91 (404.1)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|450|
|JCG-6R|170|5080|<br>15.91 (404.1)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|540|
|JCG-9R|200|5080|<br>15.91 (404.1)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|700|
|JCG-12R|230|5080|<br>15.91 (404.1)|<br>3.0 (76.2)|<br>3.0 (76.2)|Single|80,000|50,000|1,000|
|JCG-A-18R|390|5080|<br>15.91 (404.1)|<br>3.0 (76.2)|<br>3.0 (76.2)|Double|80,000|50,000|1,450|
|JCG-A-24R|450|5080|<br>15.91(404.1)|<br>3.0(76.2)|<br>3.0(76.2)|Double|80,000|50,000|2,000|
|**7200V — With Ampguard Hookeye (See Figure 1)**||||||||||
|JCR-A-2R|70|8300|15.85(402.6)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|160|
|JCR-A-3R|100|8300|15.85 (402.6)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|250|
|JCR-A-4R|130|8300|15.85 (402.6)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|325|
|JCR-A-5R|150|8300|15.85 (402.6)|3.0 (76.2)|3.0 (76.2)|Single|80,000|50,000|390|
|JCR-A-6R|170|8300|<br>15.85(402.6)|<br>3.0(76.2)|<br>3.0(76.2)|Single|80,000|50,000|500|
|JCR-A-9R|200|7200|15.85(402.6)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|750|
|JCR-A-12R|230|7200|15.85(402.6)|3.0(76.2)|3.0(76.2)|Single|80,000|50,000|1,000|
|JCR-A-18R|390|7200|15.85(402.6)|3.0(76.2)|3.0(76.2)|Double|80,000|50,000|1,450|
|JCR-A-24R|450|7200|15.85(402.6)|3.0(76.2)|3.0(76.2)|Double|80,000|50,000|2,500|
|**7200V — Bolt-On(See Figures 2 & 3)**||||||||||
|JCR-B-2R|70|8300|19.25 (488.9)|17.88 (454.1)|-|Single|80,000|50,000|160|
|JCR-B-3R|100|8300|19.25 (488.9)|17.88 (454.1)|-|Single|80,000|50,000|250|
|JCR-B-4R|130|8300|19.25 (488.9)|17.88 (454.1)|-|Single|80,000|50,000|325|
|JCR-B-5R|150|8300|<br>19.25 (488.9)|<br>17.88 (454.1)|-|Single|80,000|50,000|390|
|JCR-B-6R|170|8300|<br>19.25 (488.9)|<br>17.88 (454.1)|-|Single|80,000|50,000|500|
|JCR-B-9R|200|7200|19.25 (488.9)|17.88 (454.1)|-|Single|80,000|50,000|750|
|JCR-B-12R|230|7200|19.25 (488.9)|17.88 (454.1)|-|Single|80,000|50,000|1,000|
|JCR-B-18R|390|7200|<br>19.25 (488.9)|<br>17.88 (454.1)|3.31 (84.1)|Double|80,000|50,000|1,450|
|JCR-B-24R|450|7200|<br>19.25(488.9)|<br>17.88(454.1)|<br>3.31(84.1)|Double|80,000|50,000|2,500|
Recommended fuseclips: see page 120 - 1A0065, A3354730, 9078A67G04.
**Data Sheet: 6001**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**114**
**Medium Voltage Fuses**
## **British Standard Dimensioned IEC Fuses for Motor Circuit Protection**
The Bussmann range of motor fuses are designed to meet the specific requirements necessary for motor protection. During the starting cycle of direct on-line motors, the fuse elements will reach a considerably higher temperature than during normal operation; (this is due to the high amount of current the motor will draw as it starts, typically, six times its normal load current value). This results in expansion and contraction of the fuse elements and could cause premature operation of the fuse.
Bussmann motor fuses encompass an advanced design to minimize this effect. This therefore, negates the need to over specify the fuse rating due to high values of motor starting current.
Bussmann motor fuses operate extremely quickly under heavy fault currents, resulting from the time / current characteristic. Low power dissipation ensures low temperature rise, important in multi-tier starters for example. Switching (arc), voltages are lower than permitted values, therefore, 5.5kV fuses are also suitable for 4.8kV and 2.4kV circuits.
## **Table of Ratings**
|**Basic Cat.**<br>**Number**|**Volts**|**Breaking**<br>**Capacity**|**Amp Ratings**|**Dimensions - in(mm)**<br>~~ee~~<br>~~ee~~|**Dimensions - in(mm)**<br>~~ee~~<br>~~ee~~|**Dimensional Standard**<br>~~ee~~|
|---|---|---|---|---|---|---|
|||||**Length**<br>~~ee~~|**Diameter**<br>~~ee~~||
|3.6WJON6|3.6kV<br>~~GG~~<br>~~a Ge~~|50kA<br>~~GG~~<br>~~Ge~~|5,6.3,10,16,20,25,31.5,40,50<br>~~GG~~<br>~~**GG**~~|7.56(192)<br>~~ee~~<br>~~GG~~<br>~~**GG**~~|1.4(35.6)<br>~~ee~~<br>~~GG~~<br>~~**GG**~~|BS 2692(TA1)Interchangeable with GEC Type K2 PA<br>~~ee~~<br>~~GG~~<br>~~**GG**~~|
|3.6WDOH6|3.6kV<br>~~GG~~<br>~~a Ge~~|50kA<br>~~GG~~<br>~~Ge~~|50, 63, 80, 100, 125<br>~~GG~~<br>~~**GG**~~|7.56 (192)<br>~~GG~~<br>~~**GG**~~|2 (50.8)<br>~~GG~~<br>~~**GG**~~|BS 2692 (TA1) or DIN 43625<br>~~GG~~<br>~~**GG**~~|
|3.6WFOH6|3.6kV<br>~~a Ge~~<br>~~De~~|50kA<br>~~Ge~~<br>~~De~~|160, 200<br>~~**GG**~~|7.56 (192)<br>~~**GG**~~|3 (76.2)<br>~~**GG**~~|BS 2692 (TA1) or DIN 43625<br>~~**GG**~~|
|3.6WDLSJ|3.6kV<br>~~De~~<br>~~a~~|50kA<br>~~De~~<br>|50,63,80,100,125<br>|11.5(292.1)<br>|2(50.8)<br>|DIN 43625|
|3.6WFLSJ|3.6kV<br>~~aPO~~|50kA<br>~~PO~~|160,200<br>~~PO~~|11.5(292.1)<br>~~PO~~|3(76.2)<br>~~PO~~|DIN 43625|
|3.6WDFHO|3.6kV<br>~~PO~~<br>~~a~~|50kA<br>~~PO~~<br>|50,63,80,100,125<br>~~PO~~<br>|10(254)<br>~~PO~~<br>|2(51)<br>~~PO~~<br>|BS 2692(TA2)|
|3.6WFFHO<br>~~Po~~|3.6kV<br>~~eG~~<br>~~Po~~|50kA<br>~~eG~~<br>|160,200<br>~~eG~~<br>|10(254)<br>~~eG~~<br>|3(76.2)<br>~~eG~~<br>|BS 2692(TA2)|
|3.6WKFHO<br>~~Po~~|3.6kV<br>~~eG~~<br>~~Po~~|50kA<br>~~eG~~<br>|250,315,355,400<br>~~eG~~<br>|10(254)<br>~~eG~~<br>|3(76.2)<br>~~eG~~<br>|BS 2692(TA2)|
|5.5VFNHA<br>~~Po~~|5.5kV<br>~~PoPO~~|60kA<br>~~PO~~|2R-6R<br>~~PO~~|15.86(402.8)<br>~~PO~~|3(76.2)<br>~~PO~~|ANSI R-Rated|
|5.5VKNHA<br>|5.5kV<br>~~PO~~<br>~~GG~~|60kA<br>~~PO~~<br>~~GG~~|9R-24R<br>~~PO~~<br>~~GG~~|15.86 (402.8)<br>~~PO~~<br>~~GG~~|3 (76.2)<br>~~PO~~<br>~~GG~~|ANSI R-Rated|
|7.2WFNHO|7.2kV<br>~~GG~~<br>~~Po~~|40kA<br>~~GG~~<br>~~Po~~|25, 31.5, 40, 50, 63, 80, 100, 125, 160<br>~~GG~~<br>~~Po~~|15.86 (402.8)<br>~~GG~~<br>~~Po~~|3 (76.2)<br>~~GG~~<br>~~Po~~|BS 2692 (TA4)|
|7.2WKNHO|7.2kV<br>~~Po~~<br>~~a~~|40kA<br>~~Po~~<br>|200,224,250,315<br>~~Po~~<br>|15.86(402.8)<br>~~Po~~<br>|3(76.2)<br>~~Po~~<br>|BS 2692(TA4)|
|7.2WFMSJ|7.2kV<br>~~aPo~~|63kA<br>~~Po~~|25,31.5,40,50,63,80,125,160<br>~~Po~~|17.40(442)<br>~~Po~~|3(76.2)<br>~~Po~~|DIN 43625|
|7.2WKMSJ|7.2kV<br>~~Po~~<br>~~PO~~|63kA<br>~~Po~~<br>~~PO~~|200,224,250,315,355<br>~~Po~~<br>~~PO~~|17.40(442)<br>~~Po~~<br>~~PO~~|3(76.2)<br>~~Po~~<br>~~PO~~|DIN 43625|
## **Catalog Number Build-A-Code**
kV Basic Catalog Number
Amps
_ _ _ _ _ _ _ _ _ _ _
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**115**
**Medium Voltage Fuses**
## **DIN Dimensioned IEC Fuses for Transformer Protection**
## **DIN Dimension Fuses**
## **To Spec. DIN 43625**
## **Specifications**
**Catalog Symbol:** See Basic Catalog Numbers table. **Description:** DIN dimension fuses to Specification DIN 43625 covering current-limiting fuses with performance in compliance with IEC 60282-1. These are in accordance with the R10 and, in some cases, the R20 series of preferred numbers.
**Dimensions:** See Catalog Numbers table.
- Volts: — See voltage associated with the Basic Catalog Numbers in the table.
- Amps: — See amp rating associated with the Basic Catalog Numbers in the table.
- IR: — See IR associated with the Basic Catalog Numbers in the table.
**Agency Information:** Comply with DIN dimensional standard DIN 43625, VDE 0670 part 4, VDE 0670 part 40Z and with IEC 60282-1 (2005).
## **Features and Benefits**
- DIN dimensioned for retrofitting in existing hardware
- Open fuse indicator for ease in troubleshooting
## **Catalog Number Build-A-Code**
kV Basic Catalog Number Amps
- Designed for use in IEC equipment
## **Typical Applications**
• Medium Voltage IEC designed equipment
_ _ _ _ _ _ _ _ _ _ _
|as|||||
|---|---|---|---|---|
|**kV**<br>as<br>~~_=_—_—S=S===~~|**Catalog Numbers**<br><br>~~=_—_—S=S===~~|**Amp Ratings**<br><br>~~=_—_—S=S===~~|**Dimensions - in (mm) Diameter x Length**<br><br>~~=_—_—S=S===~~|**IR RMS Sym**<br>|
|3.6<br>as<br>~~_=_—_—S=S===~~<br>~~———~~|3.6ADOSJ(amp)<br>~~es~~<br>~~=_—_—S=S===~~|6.3,10,16,20,25, 31.5,40<br>~~QO~~<br>~~=_—_—S=S===~~|2.00x 7.56 (51 x 192)<br>~~QO~~<br>~~=_—_—S=S===~~|40kA<br>~~QO~~|
||3.6WDOSJ(amp)<br>~~es~~<br>~~=_—_—S=S===~~|50, 63, 80,100,125<br>~~QO~~<br>~~=_—_—S=S===~~|2.00x 7.56 (51 x 192)<br>~~QO~~<br>~~=_—_—S=S===~~|50kA<br>~~QO~~<br>~~es~~|
||3.6WFOSJ(amp)<br>~~es~~<br>~~=_—_—S=S===~~<br>~~———~~|160,200<br>~~QO~~<br>~~=_—_—S=S===~~|3.00x 7.56 (76x 192<br>~~QO~~<br>~~=_—_—S=S===~~||
||3.6ADLSJ(amp)<br>~~=_—_—S=S===~~<br>~~———~~|25,40<br>~~=_—_—S=S===~~|2.00x 11.50 (51 x 292)<br>~~=_—_—S=S===~~||
||3.6WDLSJ(amp)<br>~~=_—_—S=S===~~<br>~~———~~|50, 63, 80,100,125<br>~~=_—_—S=S===~~|2.00x 11.50 (51 x 292)<br>~~=_—_—S=S===~~||
||3.6WFLSJ(amp)<br>~~=_—_—S=S===~~<br>~~———~~|160,200<br>~~=_—_—S=S===~~|3.00x 11.50 (76X 292)<br>~~=_—_—S=S===~~||
||3.6WKLSJ(amp)<br>~~=_—_—S=S===~~<br>~~———~~<br>~~es~~|250, 315,400<br>~~=_—_—S=S===~~<br>~~es~~|3.00x 11.50 (76X 292)<br>~~=_—_—S=S===~~<br>~~es~~<br>~~_~~||
|7.2<br>~~_=_—_—S=S===~~<br>~~SSS~~<br>~~SSS~~|7.2TDLSJ(amp)<br>~~=_—_—S=S===~~<br>~~es~~<br>~~SSS~~|6.3,10,16,20,25, 31.5,40, 50, 63<br>~~=_—_—S=S===~~<br>~~es~~<br>~~SSS~~|2.00x 11.50 (51 x 292)<br>~~=_—_—S=S===~~<br>~~es~~<br>~~SSS~~<br>~~_~~|40kA<br>~~es~~<br>~~SSS~~<br>~~SSS~~|
||7.2TFLSJ(amp)<br>~~SSS~~|80,100,125,160<br>~~SSS~~|3.00x 11.50 (76x 292)<br>~~SSS~~<br>~~_~~||
||7.2WKMSJ(amp)<br>~~SSS~~<br>~~SSS~~|200,225,250, 315, 355<br>~~SSS~~<br>~~SSS~~|3.00x 17.41(76x 442)<br>~~SSS~~<br>~~_~~<br>~~SSS~~||
|12<br>~~SSS~~<br>~~OO~~|12TDLEJ(amp)<br>~~SSS~~|6.3,10,16,20,25, 31.5,40, 50, 63<br>~~SSS~~|2.00x 11.50 (51 x 292)<br>~~_~~<br>~~SSS~~|63kA<br>~~SSS~~|
||12THLEJ(amp)<br>~~SSS~~|80,100<br>~~SSS~~|2.52 x 11.50 (64 x 292)<br>~~SSS~~||
||12TKLEJ(amp)<br>~~SSS~~<br>~~OO~~|125<br>~~SSS~~<br>~~OO~~|3.00x 11.50 (76x 292)<br>~~SSS~~<br>~~OO~~||
||12TXLEJ(amp)*<br>~~SSS~~<br>~~OO~~|160,200<br>~~SSS~~<br>~~OO~~|3.50x 11.50 (88x 292)<br>~~SSS~~<br>~~OO~~||
|17.5<br>~~SSS~~<br>~~OO~~|17.5TDLSJ(amp)*<br>~~SSS~~<br>~~OO~~|6.3,10,16,20,25, 31.5,40<br>~~SSS~~<br>~~OO~~|2.00x 11.50 (51 x 292)<br>~~SSS~~<br>~~OO~~|35.5kA<br>~~SSS~~|
||17.5TFLSJ(amp)*<br>~~OO~~<br>~~——~~|50<br>~~OO~~<br>~~——~~|3.00x 11.50 (76x 292)<br>~~OO~~||
||17.5TDMEJ(amp)<br>~~OO~~<br>~~——~~|6.3,10,16,20,25, 31.5,40, 50, 63<br>~~OO~~<br>~~——~~|2.00x 17.41(51 x 442)<br>~~OO~~|50kA|
||17.5THMEJ(amp)<br>~~OO~~<br>~~——~~|80,100<br>~~OO~~<br>~~——~~|2.52 x 17.41(64 x 442)<br>~~OO~~||
||17.5TKMEJ(amp)<br>~~OO~~<br>~~——~~|125<br>~~OO~~<br>~~——~~|3.00x 17.41(76x 442)<br>~~OO~~||
|24<br>~~OO~~<br>~~_———SS=—=__——~~<br>~~—————____....~~|24TDMEJ(amp)<br>~~OO~~<br>~~——~~<br>~~———SS=—=__——~~|6.3, 10, 16, 20, 25, 31.5, 40, 50<br>~~OO~~<br>~~——~~<br>~~———SS=—=__——~~|2.00 x 17.41 (51 x 442)<br>~~OO~~<br>~~———SS=—=__——~~|50kA<br>~~———SS=—=__——ee~~|
||24THMEJ(amp)<br>~~———SS=—=__——~~|63<br>~~———SS=—=__——~~|2.52 x 17.41 (64 x 442)<br>~~———SS=—=__——~~||
||24TFMEJ(amp)<br>~~———SS=—=__——~~|80, 100*1<br>~~———SS=—=__——~~|3.00 x 17.41 (76 x 442)<br>~~———SS=—=__——~~||
||24TXMEJ(amp)*<br>~~———SS=—=__——~~<br>~~—————____....~~|1252, 160<br>~~———SS=—=__——~~<br>~~—————____....~~|3.46 x 17.41 (88 x 442)<br>~~———SS=—=__——~~<br>~~—————____....~~|31.5kA<br>~~———SS=—=__——ee~~|
|36<br>~~_———SS=—=__——~~<br>~~—————____....~~|36TDQSJ(amp)<br>~~———SS=—=__——~~<br>~~—————____....~~|3.153, 6.3, 10, 16, 20, 25<br>~~———SS=—=__——~~<br>~~—————____....~~|2.00 x 21.16 (51 x 537)<br>~~———SS=—=__——~~<br>~~—————____....~~|35.5kA<br>~~———SS=—=__——ee~~|
||36TFQSJ(amp)<br>~~—————____....~~|31.5, 40, 50<br>~~—————____....~~|3.00 x 21.16 (76 x 537)<br>~~—————____....~~||
||36TXQEJ(amp)*<br>~~—————____....~~<br>~~eG~~|63<br>~~—————____....~~<br>~~eG~~|3.46 x 21.16 (88 x 537)<br>~~—————____....~~<br>~~eG~~|20kA<br>~~eG~~|
- 1-IR RMS Sym is 63kA
- 2-IR RMS Sym is 40kA
- 3-IR RMS Sym is 20kA
## **Dimensions - In (mm)**
**==> picture [339 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
Striker In<br>Operated Position<br>0.59"<br>15.0mm<br>1.77"<br>45.0mm<br>eee Length 1.34" 1.02"<br>For Diameter and Length Dimensions See Table Above 34.0mm 26.0mm<br>Diameter<br>**----- End of picture text -----**<br>
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**116**
**Medium Voltage Fuses** gg
## **Expulsion Fuse Links for Use in High Voltage Distribution Cut-Outs**
## **Specifications**
**Description:** Expulsion fuse links available in a wide range of options from 15kV to 72kV in ANSI T&K characteristics.
## **Ratings:**
Volts: — 15 to 72kV Amps: — 1 to 100A Breaking Capacity: depends on voltage but is approximately 8kA
## **Agency Information:**
Type T: complies with ANSI C37-42 Type K: complies with ANSI C37-42
## **Features and Benefits**
- Wide range of options available from 15kV to 72kV in ANSI T & K characteristics.
- Extra rapid option also available.
## **Packaging:**
Up to and including 50A: 25 in a carton From 60A to 100A: 10 in a carton To avoid incorrect replacement the fuse links have colour coded labels: Pink label: Type XA Yellow label: Type K Green label: Type T
## **Typical Applications:**
- Primary side transformer protection
- Feeder protection
- Capacitor bank protection
## **Use of Application**
Expulsion fuse links current ratings should be selected on the basis of maximum expected transient no damage currents rather than on full load current. In addition, the selection of higher current ratings will reduce the possibility of supply interruption due to transient surges such as those due to lightning strikes.
Links should be handled with a reasonable degree of care when installing. Excessively rough handling may damage the element.
It is normal, under certain fault conditions, for arc extinguishing material and/or metal particles to be expelled from the fuse assembly. It is therefore recommended that reasonable precautions be taken to prevent the installation being approached by unauthorised persons.
## **How to order - Parts Referencing System**
|**How to order - Parts Referencing System**|**How to order - Parts Referencing System**|||
|---|---|---|---|
|Rated<br>Voltage<br>(kV)|1st Letter<br>Type of Current Characteristics|2nd Letter<br>Type of Termination|Rated<br>Current<br>(A)|
|15<br>25<br>46<br>72|T = complies with ANSI C 37-42 requirements for slow<br>acting T characteristics<br>K = complies with ANSI C 37-42 requirements for fast<br>acting K characteristics<br>XA = this type of expulsion fuse link has an extra rapid<br>characteristic. It is suitable for applications where a<br>high degree of system protection is required at the<br>expense of discrimination<br>S = Solid links rated at 100A are also available in both<br>button head and universal versions for fitting into<br>expulsion fuse carriers where required. These can be<br>ordered in a similar way using the abbreviation S, e.g.<br>15SB, etc|= complies with ANSI C 37-42 requirements for slow<br>B = a fixed NEMA button head link<br>U = a universal link, with double tail and slip off<br>NEMA button head<br>D = double tailed link without NEMA button<br>head<br>BR = as pattern B but the button head is<br>attached via a 1/4 UNF thread to allow use of<br>an extension rod.<br>See outline drawings opposite page for<br>reference|1, 2, 3, 4, 5,<br>6, 7.5, 8, 10,<br>12, 15, 20,<br>25, 30, 40,<br>50, 60, 65,<br>75, 80, 100|
S = Solid links rated at 100A are also available in both button head and universal versions for fitting into expulsion fuse carriers where required. These can be ordered in a similar way using the abbreviation S, e.g. 15SB, etc
Thus a typical ordering reference for a 15kV NEMA Type K, button head 30A fuse link would be 15KB30 expulsion fuse link.
The fuse link assembly for a given range is standard to all rated voltages. The exception is that the tail length is varied to suit the dimensions of expulsion carrier of different ratings.
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**117**
**Medium Voltage Fuses**
## **Expulsion Fuse Links for Use in High Voltage Distribution Cut-Outs**
## **Dimensions - mm (in)**
|Type kV|A|Notes: Type BR is similar to button|
|---|---|---|
|15kV|533 (21”)|head shown, except that the button<br>head is attached via a1⁄4 UNF thread.|
|25kV|660 (26”)|Tails can be cut to any length.|
|46kV|787 (31”)||
|72kV|1016 (40”)||
## **1-50A**
**==> picture [38 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
60-100A<br>**----- End of picture text -----**<br>
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**118**
**Medium Voltage Fuses**
## **EEI-NEMA Type K & T and Type H & N**
## **FL: Type H and EEI-NEMA Type K & T Fuses**
## **Catalog Numbers**
**EEI-NEMA and High-Surge Universal Tin Element Fuses for Cutouts — Rated to 27kV**
**Non-Removable Button-Head For Standard Open or Enclosed Cutouts**
## **Specifications**
**Description:** Medium voltage fuses: Type H (high surge), EEI-NEMA Type K (fast-acting), EEI-NEMA Type T (slow-acting).
## **Ratings:**
Amps: — 1-200A (See Catalog Numbers tables)
## **Features and Benefits**
- Wide range of EEI-NEMA type fuse links for use in open fuse cutouts
- Voltage ratings up to 27kV.
- Can be coordinated with other overcurrent protective devices for sectionalizing to isolate feeder branches.
## **Typical Applications**
- Medium Voltage Fused Cutouts
## **High-Surge Type H Fuses**
High-surge, Type H fuses are manufactured in ratings of 1, 2, 3, 5, and 8A. They have been developed principally for primary fusing of small-sized transformers. Type H links are manufactured in the universal buttonhead design.
## **Type N Fuses**
Type N fuses conform to previous NEMA standards and have been superseded by Type K and T links. Type N fuses are manufactured in the universal button design in ratings of 5 through 200A for use in NEMA standard dimensioned cutouts rated through 27kV.
|**Type H**|**EEI-NEMA**|**EEI-NEMA**||
|---|---|---|---|
|**Type H**<br>**(High**<br>**Surge)**|**EEI-NEMA**<br>**Type K**<br>**(Fast)**|**EEI-NEMA**<br>**Type T**<br>**(Slow)**|**Amps**|
|**Surge)**<br>FL11H1|**(Fast)**<br>FL11K1|**(Slow)**<br>FL11T1|**Amps**<br>1|
|FL11H2|FL11K2|FL11T2|2|
|FL11H3|FL11K3|FL11T3|3|
|FL11H5|FL11K5|FL11T5|5|
|—|FL11K6|FL11T6|6|
|FL11H8|FL11K8|FL11T8|8|
|—|FL11K10|FL11T10|10|
|—|FL11K12|FL11T12|12|
|—|FL11K15|FL11T15|15|
|—|FL11K20|FL11T20|20|
|—|FL11K25|FL11T25|25|
|—|FL11K30|FL11T30|30|
|—|FL11K40|FL11T40|40|
|—|FL11K50|FL11T50|50|
|—|FL11K65|FL11T65|65|
|—|FL11K80|FL11T80|80|
|—|FL11K100|FL11T100|100|
|—|FL11K140|FL11T140|140|
|—|FL11K200|FL11T200|200|
Removable Button-Head For Cutouts Requiring Removable-Button Links
## **Catalog Numbers**
|**EEI-NEMA**<br>**Type K**<br>**(Fast)**|**EEI-NEMA**<br>**Type T**<br>**(Slow)**|**Amps**|
|---|---|---|
|FL3K1|FL3T1|1|
|FL3K2|FL3T2|2|
|FL3K3|FL3T3|3|
|FL3K5|FL3T5|5|
|FL3K6|FL3T6|6|
|FL3K8|FL3T8|8|
|FL3K10|FL3T10|10|
|FL3K12|FL3T12|12|
|FL3K15|FL3T15|15|
|FL3K20|FL3T20|20|
|FL3K25|FL3T25|25|
|FL3K30|FL3T30|30|
|FL3K40|FL3T40|40|
|FL3K50|FL3T50|50|
|FL3K65|FL3T65|65|
|FL3K80|FL3T80|80|
|FL3K100|FL3T100|100|
|FL3K140|FL3T140|140|
|FL3K200|FL3T200|200|
Adapter-type removable-button links with ferrule adapter to convert to double-leader links are available in K and T types. Order by description.
## **EEI-NEMA Type K Universal Silver-Element Fuses for Cutouts — Rated through 27kV**
**Non-Removable Button-Head For Standard Open or Enclosed Cutouts**
|**EEI-NEMA**||
|---|---|
|**EEI-NEMA**<br>**Type K**|**Amps**|
|**Type K**<br>FL12K8|**Amps**<br>8|
|FL12K10|10|
|FL12K12|12|
|FL12K15|15|
|FL12K25|25|
|FL12K50|50|
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**119**
**Medium Voltage Fuses**
## **Fuseclips for Medium & High Voltage Fuses**
## **Recommended Fuseclips for Medium Voltage Fuses**
|**Catalog**<br>**Numbers**<br>A3354710<br>A3354730<br>A3354745<br>Fuseclips are for single barrel applications only. Are not sold in pairs.|**Fuse**<br>**Diameter -**<br>**in(mm)**<br>2(50.8)<br>3 (76)<br>1.77 (45)<br>Fuseclips are for single barrel applications only. Are not sold in pairs.|**A**<br>3.749<br>4.139<br>3.50<br>Fuseclips are for single barrel applications only. Are not sold in pairs.|**B**<br>1.979<br>2.449<br>2.50<br>Fuseclips are for single barrel applications only. Are not sold in pairs.|**Clip Dimensions (in)**<br>**C**<br>**D**<br>**E**<br>2.009<br>1.189<br>4.539<br>3.009<br>1.189<br>5.639<br>1.77<br>1.19<br>4.50<br>Fuseclips are for single barrel applications only. Are not sold in pairs.|**F**<br>1.509<br>1.509<br>1.50|**G**<br>0.399<br>0.399<br>0.38|C<br>B<br>(\~~a~~<br>\Wo»<br>©<br>| I<br>Nee,|A||||~~D~~|||G<br>~~F~~<br>i~~e~~<br>~~> ~~<br>~~pao~~|~~E~~<br>|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
**==> picture [470 x 234] intentionally omitted <==**
**----- Start of picture text -----**<br>
1A0065 i Giovt (10 Ga.) 270303<br>3˝ Diameter Clip DIN Fuseclip<br>A<br>0.99"<br>25.0mm<br>f4ago}Viz Ie | (ih @ 0 : P :<br>| cPygepo8, enone -<br>H CPupseyon,SPRING Reon 7<br>4.06"<br>; {1.560}39.62 - 103mm 7| |<br>34.10 + | |<br>| | [466] =<br>| 26.92 I UW<br>{4.000}<br>—H<br>2 CUP ASSEMSLIES PER PACKAGE.<br>DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. 10.8mm0.43"<br>A<br>**----- End of picture text -----**<br>
**9078A67G04 3˝ Diameter Clip**
2 Cup assemblies per package. Dimensions shown are for reference only.
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**120**
## **High Speed Fuses**
## **Section Contents**
**Page**
General Applications . . . . . . . . . . . . . . . . . . . . . . .122-123 North American fuses & accessories . . . . . . . . . . .124-141 DFJ - High speed Class J fuse . . . . . . . . . . . . . . . . . .125 Square Body fuses & accessories . . . . . . . . . . . . 142-213 BS 88 fuses & accessories . . . . . . . . . . . . . . . . . .214-222 Ferrule fuses & accessories. . . . . . . . . . . . . . . . . .223-243
Scan this tag to get the latest product information for High Speed Fuses.
**==> picture [6 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
TM<br>**----- End of picture text -----**<br>
**121**
**High Speed Fuses**
## **General Applications**
## **Rated Voltage**
The AC voltage rating of Bussmann fuses is given in volts rms. Fuses tested to IEC are tested at 5% above their rated voltage. British Style BS 88 fuses are tested at 10% above its rated voltage. UL recognition tests are performed at the rated voltage.
## **Rated Current**
Rated current is given in amps rms. Bussmann fuses can continuously carry the rated current.
## **Melting Characteristic**
|The melting<br>characteristic<br>shows the virtual<br>melting time in<br>seconds as a<br>function of the<br>prospective current<br>in amps rms. The<br>fuses are specially<br>constructed for<br>short-circuit<br>protection against<br>high level fault<br>currents. Loading<br>and operation of<br>the fuse in the non-<br>continuous/dashed<br>section of the melt<br>curve must be<br>avoided. The curve<br>can also be read<br>as the real melting<br>time as a function<br>of the RMS value<br>of the pre-arc current.<br>10<br>4<br>10<br>3<br>10<br>2<br>2<br>4<br>6<br>2<br>6<br>4<br>100<br>2<br>6<br>4<br>10<br>1<br>2<br>6<br>4<br>2<br>6<br>4<br>2<br>6<br>4<br>6<br>4<br>2<br>6<br>2<br>4<br>Virtual Pre-Arcing Time In Seconds<br>10<br>–4<br>10<br>–3<br>10–2<br>10–1|10<br>1<br>**2**<br>4<br>6<br>8<br>**2**<br>102<br>4<br>6<br>8 103<br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br>Prospective Current In Amperes RMS|
|---|---|
|||
**==> picture [247 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
Clearing Integrals 1.5<br>K<br>The total clearing I [2] t at 1.0<br>rated voltage and at<br>power factor of 15% are<br>given in the electrical<br>0.5<br>characteristics. For<br>0.4<br>other voltages, the<br>clearing I [2] t is found by 0.3<br>multiplying by correction<br>factor, K, given as a 0.2 E<br>function of applied g<br>working voltage, Eg, 100 200 300 400 500 600 660<br>(rms).<br>**----- End of picture text -----**<br>
**==> picture [248 x 424] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power Factor X<br>For other power factor 1.0<br>values, the total clearing<br>integral can be<br>calculated as a multiple<br>0.9<br>of the clearing integrals,<br>the correction factor K<br>and the correction factor<br>X. 0.8<br>Arc Voltage 0.7 0.1 0.2 0.3 0.4 0.5<br>This curve gives the COS �<br>1.4<br>peak arc voltage, UL, 1.2 UL<br>which may appear 10 [3]<br>across the fuse during its 9<br>8<br>operation as a function 7<br>of the applied working 6<br>voltage, Eg, (rms) at a 5<br>power<br>4<br>factor of 15%.<br>3 Eg<br>Power Losses 200 300 400 500 600 660<br>Watts loss at rated 1.0<br>current is given in the 0.8 Kp<br>electrical characteristics. 0.6<br>0.5<br>The curve allows the<br>0.4<br>calculation of the power<br>0.3<br>losses at load currents<br>lower than the rated 0.2<br>current. The correction<br>factor, Kp , is given as a 0.1 Ib<br>function of the RMS load 30 40 50 60 70 80 90 100%<br>current, Ib , in % of the<br>rated current .<br>**----- End of picture text -----**<br>
## **Cut-Off Current**
A fuse operation relating to short-circuits only. When a fuse operates in its current-limiting range, it will clear a short-
**==> picture [253 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [5]<br>10 [4]<br>10 [3] A<br>B<br>2 ≈ 10 2102 10 [3] 10 [4] 10 [5] 10 [6]<br>Prospective Current in Amps RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
circuit in less than[1] ⁄2 cycle. Also, it will limit the instantaneous peak let-through current to a value substantially less than
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**122**
**High Speed Fuses**
## **General Applications**
that obtainable in the same circuit if that fuse were replaced with a solid conductor of equal impedance. A asymmetrical current B symmetrical current
## **Parallel Connection**
When fuses are connected in parallel it is recommended that the applied voltage does not exceed 0.9 UN (the rated voltage of the fuse). This is due to the fact that the energy released within the fuses may be unevenly shared between the parallel connected barrels.
When fuses are connected in parallel, one must take into account that the current sharing is not necessarily equal. And it must be checked, that the maximum load current is not exceeded.
## **Series Connection**
Fuses in series may not equally divide the applied voltage. It is recommended that series connected fuses should only be operated at fault currents that yield melting times less than 10 ms and a recovery voltage per fuse of less than or equal to 0.9 UN (the rated voltage of the fuse).
## **Mounting Guidance**
The recommendations below have to be followed when mounting a Bussmann fuse with end plate threaded holes.
1. Screw in studs: 5 N•m Max, 3 N•m Min
2. Attachment of the fuse to bussbar by means of nut and washer:
|washer:|||
|---|---|---|
|**Thread**|**Torque**|**(N•m)***|
|**Configuration**<br>5⁄16” –18, M8<br>3⁄8” –16, M10|**Max**<br>25<br>45|**Min**<br>20<br>40|
|3⁄8” –24|45|40|
|1⁄2” –13, M12<br>1⁄2” –20<br>*1 N•m = 0.7375 lb-ft|65<br>65|50<br>50|
## **Overloads**
The design of Bussmann fuses is such that they can be operated under rather severe operating conditions imposed by overloads (any load current in excess of the maximum permissible load current).
In applications, there will be a maximum overload current, Imax, which can be imposed on the fuse with a corresponding duration and frequency of occurrence.
Time durations fall into two categories:
1. Overloads longer than one second
2. Overloads less than one second termed “impulse” loads.
The following table gives general application guidelines which, in the expression Imax < (% factor) x It. It is the
melting current corresponding to the time “t” of the overload duration as read from the time-current curve of the fuse. The guidelines in the table below determine the acceptability of the selected fuses for a given Imax[.]
**Frequency of Occurrence Overloads (> 1 sec) Impulse Loads (< 1 sec)** Less than once per month Imax < 80% x It Imax < 70% x It Less than twice per week Imax < 70% x It Imax < 60% x It Several times per day Imax < 60% x It —
When impulse loads are an intrinsic/normal parameter of the load current either as single pulse or in trains of pulses or when their level is higher than the melting current at 0.01 seconds (per time-current curve), contact Bussmann for application assistance.
In addition to the parameters set forth in the preceding table, the RMS value of the load current as calculated for any period of 10 minutes or more should not exceed the maximum permissible load current.
Furthermore, it is important that a fuse should not be applied in the non-continuous/dashed portion of the associated time-current curve.
Any time-current combination point which falls in the non-continuous/dashed portion of the time-current curve is beyond the capability of the fuse to operate properly.
## **DC Operation**
Depending upon the short-circuit time constant and the magnitude of the prospective short-circuit current, the dc voltage at which a fuse can be applied may be less than its ac rating. Long time constants require a lower dc voltage. Conversely, however, higher available prospective shortcircuit currents result in faster fuse openings and thus permit a fuse to be operated at a higher DC voltage.
|Consult Bussmann for<br>additional information and<br>application assistance<br>when fuses have to<br>operate under DC<br>conditions.<br>**Load Current Versus**|1.0<br>0.9<br>0.8<br>Reduction|1.0<br>0.9<br>0.8<br>Reduction|1.0<br>0.9<br>0.8<br>Reduction|Factor|Factor||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**Conductor Cross**<br>**Section**|0.5||0.6|0.7|0.8||0.9||1.0||
|Reduction of ermissible|||≈ (IEC|cross|section)||||||
Reduction of permissible
load current when the conductor cross section is less than that given in IEC Publication 269-1 & 4 valid for Bussmann high speed fuses.
## **Application Assistance**
If you have application problems or need a fuse outside our standard program, please contact the nearest Bussmann representative. Phone numbers are shown on the back cover.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**123**
**High Speed Fuses**
## **North American Fuses**
## **Introduction**
|**North American Contents**|**North American Contents**|||
|---|---|---|---|
|**Catalog**<br>**Number**<br>DFJ|**Volts**<br>600|**Amp**<br>**Range**<br>1-600|**Page**<br>125|
|FWA|130|1000-4000|126-127|
|FWA|150|70-1000|128-129|
|FWX|250|35-2500|130-131|
|FWH<br>KAC<br>KBC<br>FWP|500<br>600<br>600<br>700|35-1600<br>1-1000<br>35-800<br>5-1200|132-133<br>134<br>135<br>136-138|
|FWJ|1000|35-2000|139-140|
## **Accessories**
Fuse Bases 141
|**North American Fuse Ranges**|**North American Fuse Ranges**|**North American Fuse Ranges**||
|---|---|---|---|
|**Amps**<br>1000-4000|**Volts**<br>130|**AC**<br>X|**DC**<br>X|
|70-1000|150|X|X|
|35-2500<br>35-1600<br>1-1000|250<br>500<br>600|X<br>X<br>X|X<br>X<br>—|
|5-1200|700|X|X|
|40-600|800|—|X|
|35-2000|1000|X|—|
## **General Information**
Bussmann offers a complete range of North American blade and flush-end style fuses and accessories. Their design and construction were optimized to provide:
- Low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
- Low arc voltage
- Excellent DC performance
North American style fuses provide an excellent solution for medium power applications. While there are currently no published standards for these fuses, the industry has standardized on mounting centers that accept Bussmann fuses.
## **Voltage Rating**
All Bussmann North American style fuses are tested at their rated voltage. Bussmann should be consulted for applications exceeding those values.
## **Accessories**
External and internal open fuse indication is available for selected portions of the North American line. Fuse blocks are available for most applications.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**124**
**High Speed Fuses**
## **Drive Fuse High Speed Fuses**
## **DFJ Class J**
## **Time-Current Characteristic Curves—Average Melt**
## **Specifications**
**Description:** High speed, current-limiting fuse. The Bussmann Drive Fuse will provide maximum protection for AC and DC drives and controllers and meet NEC[®] branch circuit protection requirements. The Drive Fuse has the lowest I[2] t of any branch circuit fuse to protect power semiconductor devices that utilize diodes, GTOs, SCRs and SSRs.
**Dimensions:** See page 21 for Class J dimensions. **Construction:** Melamine tube with silver fuse element.
## **Ratings:**
Volts — 600Vac (or less), 450Vdc (or less)
Amps — 1-600A
IR — 200kA RMS Sym., 100kA DC
**Agency Information:** CE, Std. 248-8, Class J, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787.
## **Current Limitation Curves**
## **Features and Benefits**
- Easily coordinated with existing and new variable speed drives and electric controllers.
- Standard Class J dimensions allowing the use of readily available fuse blocks, holders, and switches.
- Allows the lowest let-thru energy of any branch circuit overcurrent protective device.
## **Typical Applications**
- Protection of AC and DC drives
• Equipment using power semiconductor devices
|**Catalog Numbers(Amps)**<br>DFJ-1<br>DFJ-15<br>DFJ-70<br>DFJ-225<br>DFJ-2<br>DFJ-20<br>DFJ-80<br>DFJ-250<br>DFJ-3<br>DFJ-25<br>DFJ-90<br>DFJ-300<br>DFJ-4<br>DFJ-30<br>DFJ-100<br>DFJ-350<br>DFJ-5<br>DFJ-35<br>DFJ-110<br>DFJ-400<br>DFJ-6<br>DFJ-40<br>DFJ-125<br>DFJ-450<br>DFJ-8<br>DFJ-45<br>DFJ-150<br>DFJ-500<br>DFJ-10<br>DFJ-50<br>DFJ-175<br>DFJ-600<br>~~ee~~<br>~~a~~<br>~~ee~~|
|---|
|DFJ-12<br>DFJ-60<br>DFJ-200|
**Data Sheet: 1048**
For product data sheets, visit www.cooperbussmann.com/datasheetsele
**125**
**High Speed Fuses**
## **North American — FWA 130V: 1000-4000A**
## **Arc Voltage**
## **FWA**
**==> picture [9 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
UL<br>**----- End of picture text -----**<br>
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%.
## **Specifications**
**Description:** North American style flush-end high speed fuses. **Dimensions:** See Dimensions illustrations.
300 may appear across the fuse during its operation as a function of the 200 | applied working voltage, Eg, (rms) at a power 100 Ba factor of 15%. E g aa **Power Losses** 50 100 150 Watts loss at rated current is given in the electricalcharacteristics. The curve 1.00.8 SSS Kp allows the calculation of 0.6 0.5 the power losses at load 0.4 SE A currents lower than the rated current. The 0.3 PPP Yee correction factor, Kp, is 0.2 given as a function of the RMS load current, Ib, in % CVE of the rated current. 0.1 CELL Ibb 30 40 50 60 70 80 90 100%
## **Ratings:**
Volts: — 130Vac
Amps: — 1000-4000A
IR: — 200kA RMS Sym.
— 50kA @130Vdc
**Agency Information:** CE, UL Recognized JFHR2.E91958 on 1000-2000A fuses
## **Electrical Characteristics**
## **Total Clearing I[2] t**
The total clearing I[2] t at 1.5 K correction factor, Kp, is 0.2 given as a function of the rated voltage and at power 1.0 Saceeeenes RMS load current, Ib, in % CVE factor of 15% are given in of the rated current. 0.1 CELL Ibb the electrical 30 40 50 60 70 80 90 100% characteristics. For othervoltages, the clearing I[2] t is 0.5 SEE EEE **Catalog Numbers Electrical Characteristics** found by multiplying by 0.3 SCOOT **I[2] t (A[2] Sec)** correction factor, K, givenas a function of applied 0.150.2 BERRPT TE eT TE TT Eg FWA-1000AH **CatalogNumbers Rated CurrentRMS** 1000 **-Amps Pre** 170000 **-arc at 130VClearing** 460000 **WattsLoss** 60 working voltage, Eg, (rms). 26 65 104 130 FWA-1200AH 1200 270000 730000 70 FWA-1500AH 1500 520000 1400000 78 FWA-2000AH 2000 860000 2400000 108 FWA-2500AH 2500 1500000 4100000 130 FWA-3000AH 3000 2100000 5700000 150 — ~~AP~~ FWA-4000AH 4000 3400000 9200000 257 • Watts loss provided at rated current. **Dimensions - in** • See accessories on page 141. **Catalog Number Fig. B C D Thread Depth** FWAFWAFWA---1000AH2500AH4000AH--2000AH3000AH 112 2.03.03.5 1.01.51.5 ——1.5 Tapped Tapped Tapped[3][1][1] ⁄⁄⁄822”-”-”-24 x 20 x 20 x[1][1][1] ⁄⁄⁄222””” • **Features and Benefits** Excellent DC performance 1mm = 0.0394˝ / 1˝ = 25.4mm • Low arc voltage and low energy let-through (I[2] t) • Low watts loss Fig. 1: 1000-3000A Fig. 2: 4000A • Superior cycling capability **Typical Applications** • DC Common bus 1.875 • DC Drives 1.875 • Power converters/rectifiers • Reduced voltage starters ~~( L~~ | ~~| _ <>~~ D ~~) —~~ B O® ~~©~~ \\-* C B C | o J)» | @ o//—
**Data Sheet: 720001**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**126**
**High Speed Fuses**
## **North American — FWA 130V: 1000-4000A**
## **FWA 1000-4000A: 130V**
## **Time-Current Curve**
**==> picture [252 x 401] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4 FWA-1000AH<br>FWA-1200AH<br>2 FWA-1500AH<br>FWA-2000AH<br>10 [2]<br>FWA-2500AH<br>6<br>FWA-3000AH<br>4<br>FWA-4000AH<br>2<br>10 [1]<br>6<br>4<br>2<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>10 [3] 2 4 6 8 10 [4] 2 4 6 8 105<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [360 x 192] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>10 [5]<br>6<br>4<br>2<br>FWA-4000AH<br>FWA-3000AH<br>10 [4] FWA-2500AH<br>FWA-2000AH<br>FWA-1500AH<br>6 FWA-1200AH<br>FWA-1000AH<br>4<br>2<br>10 [3]<br>10 [3] 2 4 6 10 [4] 2 4 6 10 [5] 2 4 6<br>Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785301<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**127**
**High Speed Fuses**
## **North American — FWA 150V: 70-1000A**
## **FWA**
## **Arc Voltage**
This curve gives the peak UL **Specifications Description:** North American style arc voltage, UL, which may 300 stud-mount fuses. appear across the fuse during its operation as a **Dimensions:** See Dimensions function of the applied 200 illustrations. 2 Hee working voltage, Eg, (rms) **Ratings:** at a power factor of 15%. 100 Volts:— 150Vac/dc* E **Power Losses** g ae Amps:— 70-1000A IR:— 100kA Sym. (70-400A) | Watts loss at rated current 50 100 150 1.0 — 200kA Sym. (450-1000A) is given in the electricalcharacteristics. The curve 0.8 === Kp — 20kA @150Vdc (70-800A) allows the calculation of 0.6 0.5 — 100kA @ 80Vdc (70-1000A) the power losses at load 0.4 FERRE *1000A rated @ 80Vdc. currents lower than the 0.3 a4 **Agency Information:** CE, UL Recognized JFHR2.E91958 rated current. The correction factor, Kp, is 0.2 LYEty **Electrical Characteristics** given as a function of the 1.5 a AAT **Total Clearing I[2] t** K RMS load current, Ib, in %of the rated current. 0.1 AEE Ib 1.0 L ET The total clearing I[2] t at rated 30 40 50 60 70 80 90 100% **Catalog Numbers** voltage and at power factor So **Electrical Characteristics** of 15% are given in the 0.5 **Rated I[2] t (A[2] Sec)** electrical characteristics. For HEE 1) **Catalog Current Clearing Watts** other voltages, the clearing 0.3 **Number** FWA-70B **RMS-** 70 **Amps Pre-** 470 **arc at 150V** 4000 **Loss** 6.9 I[2] t is found by multiplying by 0.2 IA] 2) | | | Tt | FWA-80B 80 670 6000 7.7 correction factor, K, given as Fi tT TT tt FWA-100B 100 1200 12000 9.0 Eg FWA-125B 125 1870 18000 11.2 a function of applied working 0.1522 PTET 70 TTT 102 Ty 150 FWA-150B 150 2700 26000 13.5 voltage, Eg, (rms). 1) 500-1000A Range FWA-200BFWA-250B 200250 47807470 4500070000 17.622.5 2) 70-400A Range FWA-300B 300 10760 100000 27.0 FWA-350B 350 15700 140000 30.6 FWA-400B 400 20300 180000 35.2 FWA-500A 500 39000 120000 35.0 **Dimensions - in** FWA-600A 600 46000 140000 47.0 FWA-700A 700 75000 220000 49.0 Fig. 1: 70-400A FWA-800A 800 92000 280000 58.0 FWA-1000A 1000 170000 510000 60.0 2.656 ~~_ TTT~~ 2.188 • Watts loss provided at rated current. • See accessories on page 141. 1.936 1.156 0.125 **Features and Benefits** • ~~SE —_—— 7 <~~ Excellent DC performance 0.750 0.312 1.000 • Low arc voltage and low energy let-through (I[2] t) ~~el~~ • Low watts loss ~~ek~~ el 0.438 ~~©~~ ® • Superior cycling capability Fig. 2: 500-1000A **Typical Applications** • DC Common bus 3.500 • DC Drives 2.438 • Power converters/rectifiers 1.250 0.250 • Reduced voltage starters ~~hr = al~~ ae 1.000 1.500 ” L\ ~~le~~ 0.406 l e ~~l L~~ O 1mm = 0.0394” / 1” = 25.4mm
**Data Sheet: 720002**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**128**
**High Speed Fuses**
## **North American — FWA 150V: 70-1000A**
## **FWA 70-1000A: 150V**
## **Time-Current Curve**
**==> picture [218 x 349] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4 FWA-500A<br>FWA-600A<br>2 FWA-700A<br>FWA-800A<br>10 [2] FWA-1000A<br>6<br>4<br>2<br>10 [1]<br>6<br>4<br>2<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6 FWA-70A<br>4 FWA-80A<br>FWA-100A<br>2 FWA-125A<br>FWA-150A<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6 FWA-200A<br>4 FWA-250A<br>FWA-300A<br>2 FWA-350A<br>FWA-400A<br>10 [–4]<br>10 [2] 2 4 6 8 103 2 4 6 8 104<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [252 x 206] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [6]<br>6<br>4<br>FWA-400A<br>FWA-350A<br>2 FWA-300A<br>FWA-250A<br>10 [4] FWA-200A<br>FWA-150A<br>6 FWA-100A<br>4<br>2<br>10 [3]<br>6 FWA-80A<br>4 FWA-70A<br>2<br>10 [2]<br>2 4 6 2 4 6 2 4 6 2<br>10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Data Sheet: 35785310**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**129**
**High Speed Fuses**
## **North American — FWX 250V: 35-2500A**
## **FWX**
## **Specifications**
**Description:** North American style stud-mount and flush-end fuses.
**Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts:— 250Vac/dc
Amps:— 35-2500A
IR:— 200kA RMS Sym.
50kA@250Vdc (35-800A)
**Agency Information:** CE, UL Recognized JFHR2.E56412 & CSA Component Acceptance file Class 1422-30, (53787) on 35-800A fuses (50kA IR @250Vdc).
**Electrical** 1.5 **Characteristics** K §======——= 1.0 **Total Clearing I[2] t** The total clearing I[2] t at rated voltage and at power factor 0.5 LbLfa 1) | | ft tT PACT of 15% are given in the 4RRRREREEE 2) electrical characteristics. 0.3 For other voltages, the 0.2 PEPE Scceeeee8 clearing I[2] t is found by 0.15 Eg multiplying by correction 75 LTTE 125 TET 200 250 et 300 factor, K, given as a 1) 35-800A Range function of applied working 2) 1000-2500A Range voltage, Eg, (rms).
## **Dimensions - in**
|||||||||||**Tapped**|
|---|---|---|---|---|---|---|---|---|---|---|
|**Amp**||||||||||**Thread**|
|**Range**|**Fig. A**<br>**B**||**C**|**D**|**E**|**F**|**G**|**H**|**J**|**Depth**|
|35-60|1|3.19 0.81|1.59|2.59|2.25|0.34|0.63|0.13|0.52|—|
|70-200|1|3.13 1.22|1.59|2.44|2.19|0.34|1.00|0.19|0.47|—|
|225-600|1|3.84 1.50|1.59|2.94|2.25|0.41|1.00|0.25|0.75|—|
|700-800|1|3.84 2.00|1.59|3.03|2.28|0.41|1.50|0.25|0.78|—|
|1000-1200|2|2.59 3.00|1.50|—|—|—|—|—|—|3⁄8”-24 x1⁄2”|
|1500-2500|3|2.59 3.50|1.50|1.50|—|—|—|—|—|3⁄8”--24 x1⁄2”|
|1mm = 0.0394” / 1” = 25.4mm||1mm = 0.0394” / 1” = 25.4mm|||||||||
Fig. 1: Fig. 2: Fig. 3: 35-800A 1000-1200A 1500-2500A J fh ~~for~~ oo A im A my ~~t~~ S A D E C D B C B C F ~~ran~~ G H ~~‘©~~ B
## **Arc Voltage**
**==> picture [243 x 239] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.4<br>This curve gives the peak 1.2 UL<br>10 [3] ==<br>arc voltage, UL, which may<br>800<br>appear across the fuse<br>during its operation as a 600<br>function of the applied 500<br>working voltage, Eg, (rms) 400 1)<br>at a power factor of 15%. 300<br>2)<br>Power Losses 200 pit Eg<br>Watts loss at rated current is 50 100 150 | 200 250<br>given in the electrical char 1) 35-800A Range2) 1000-2500A Range<br>acteristics. The curve allows 1.00.8 oe Kp<br>the calculation of the power<br>0.6<br>losses at load currents lower 0.5 oo one<br>than the rated current. The 0.4 ooo 40<br>0.3 Pt | Yi [|<br>correction factor, Kp , is<br>given as a function of the 0.2<br>RMS load current, Ib , in % Pt IAL | tT<br>ATE<br>of the rated current . 0.1 Ib<br>30 40 50 60 70 80 90 100%<br>**----- End of picture text -----**<br>
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%.
## **Power Losses**
## **Catalog Numbers**
|**Catalog Numbers**<br>**Catalog**<br>**Number**|**Catalog Numbers**<br>**Electrical Characteristics**|**Catalog Numbers**<br>**Electrical Characteristics**|**Catalog Numbers**<br>**Electrical Characteristics**|**Catalog Numbers**<br>**Electrical Characteristics**|
|---|---|---|---|---|
||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**||**Watts**<br>**Loss**|
|||**Pre-arc**|**Clearing**<br>**at 250V**||
|FWX-35A<br>FWX-40A<br>FWX-45A<br>FWX-50A<br>FWX-60A<br>FWX-70A<br>FWX-80A<br>FWX-90A<br>FWX-100A<br>FWX-125A<br>FWX-150A<br>FWX-175A<br>FWX-200A<br>FWX-225A<br>FWX-250A<br>FWX-275A<br>FWX-300A<br>FWX-350A<br>FWX-400A<br>FWX-450A<br>FWX-500A<br>FWX-600A<br>FWX-700A<br>FWX-800A<br>FWX-1000AH<br>FWX-1200AH<br>FWX-1500AH<br>FWX-1600AH<br>FWX-2000AH<br>FWX-2500AH|**RMS-Amps**<br>35<br>40<br>45<br>50<br>60<br>70<br>80<br>90<br>100<br>125<br>150<br>175<br>200<br>225<br>250<br>275<br>300<br>350<br>400<br>450<br>500<br>600<br>700<br>800<br>1000<br>1200<br>1500<br>1600<br>2000<br>2500|50<br>60<br>80<br>100<br>140<br>330<br>430<br>570<br>740<br>1130<br>1620<br>2170<br>2790<br>3210<br>3960<br>4720<br>6000<br>10600<br>14500<br>22100<br>28000<br>41100<br>48800<br>59000<br>44000<br>92000<br>120000<br>160000<br>320000<br>670000|230<br>310<br>390<br>520<br>740<br>1400<br>1850<br>2450<br>3150<br>4850<br>6950<br>9300<br>12000<br>14700<br>18100<br>21600<br>27300<br>48600<br>66100<br>101000<br>128000<br>188000<br>190000<br>230000<br>360000<br>750000<br>880000<br>1200000<br>2300000<br>4700000|4.2<br>5.2<br>5.7<br>6.0<br>8.1<br>7.2<br>8.1<br>9.0<br>10.0<br>12.5<br>15.7<br>18.5<br>22<br>24<br>27<br>31<br>32<br>39<br>44<br>49<br>54<br>62<br>72<br>84<br>100<br>103<br>140<br>140<br>151<br>163|
## **Typical Applications**
## **Features and Benefits**
- DC Common bus
- Excellent DC performance
- DC Drives
- Low arc voltage and low energy let-through (I[[2]] t)
- energy let-through (I[[2]] t) • Power converters/rectifiers
- • Superior cycling capability • Reduced voltage starters
**Data Sheet: 720005**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**130**
**High Speed Fuses**
## **North American — FWX 250V: 35-2500A**
## **FWX 1000-2500A(H): 250V**
## **FWX 35-800A: 250V**
## **Time-Current Curve**
## **Time-Current Curve**
**==> picture [252 x 272] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>10 [3]<br>FWX-200A<br>FWX-350A<br>10 [2] FXW-400A<br>FWX-500A<br>FWX-600A<br>FWX-800A<br>10 [1]<br>10 [0]<br>FWX-35A<br>FWX-40A<br>10 [–1] FWX-60A<br>FWX-70A<br>FWX-100A<br>FWX-150A<br>10 [–2]<br>10 [–3]<br>10 [–4]<br>2 10 [2] 10 [3] 10 [4]<br>Prospective Current In Amps RMS<br>Virtual Pre-arcing Time In Seconds<br>**----- End of picture text -----**<br>
**==> picture [233 x 380] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2 FWX-1000AH<br>10 [2] FWX-1200AH<br>FWX-1500AH<br>6<br>4 FWX-1600AH<br>FWX-2000AH<br>2 FWX-2500AH<br>10 [1]<br>6<br>4<br>2<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [[–3]]<br>6<br>4<br>2<br>10 [[–4]]<br>10 [[3]] 2 4 6 8 10 [[4]] 2 4 6 8 1055<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [511 x 280] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [5]<br>10 [[–3]]<br>B<br>6<br>4<br>2<br>FWX-800A<br>FWX-600AFWX-400AFWX-300A 10 [[–4]] 10 [[3]] 2 4 6 8 10 [[4]] 2 4 6 8 1055<br>FWX-200A Prospective Current In Amps RMS<br>10 [4]<br>Peak Let-Through Curve<br>10 [5]<br>6<br>FWX-2500AH<br>4 FWX-2000AH<br>10 [3] FWX-1600AH<br>FWX-150AFWX-100AFWX-70A 2 FWX-1500AHFWX-1200AH<br>FWX-60A FWX-1000AH<br>A FWX-45AFWX-35A<br>10 [4]<br>6<br>4<br>10 [2]<br>10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS 2<br>10 [3]<br>10 [3] 2 4 6 10 [4] 2 4 6 10 [5] 2 4 6<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Data Sheet: 35785299**
**Data Sheet: 359**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**131**
**High Speed Fuses**
## **North American — FWH 500V: 35-1600A**
## **FWH**
## **Arc Voltage**
**Arc Voltage** 2.0 UL This curve gives the peak 1.6 arc voltage, UL, which 1 1.2 may appear across the 10[3] fuse during its operation 800 a ee ee eee es eS ee ee as a function of theapplied 600 2) working voltage, Eg, (rms) 500 ——— at a power 1) 400 factor of 15%. Annee 300 Eg **Power Losses** 100 200 300 400 500 1) 35-200 & 1000-1600A Range Watts loss at rated 2) 225-800A Range TTS 1.0 current is given in the 0.8 SS Kp SSS electrical characteristics. 0.6 ee The curve allows the 0.5 Yr | | [|[[A]] i Pe calculation of the power 0.4 Pt t| | YI | | losses at load currents 0.3 Ft] lower than the rated current. The correction 0.2 PT YLYi tL| | factor, Kp, is given as a function of the RMS load ATI current, Ib, in % of therated current.rated current. 0.1 30 ALLEL 40 50 60 70 80 90Ib100%
## **Specifications**
**Description:** North American style stud-mount fuses.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 500Vac/dc (35-800A only)
Amps: — 35-1600A
IR: — 200kA Sym.
— 50kA @ 500Vdc (35-800A)
**Agency Information:** CE, UL Recognition JFHR2.E91958 FWH-_B (35-200A, 1000-1200A), JFHR2.E56412 FWH-_A (225-600A), CSA Component Acceptance Class 1422-30, File 53787 (35-1600A).
## **Electrical Characteristics**
**==> picture [477 x 350] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|1.5|
|Total Clearing I|[[2]]|t|K|factor, Kp, is given as a|
|The total clearing I|[2]|t at rated|1.0|§2===>>===|function of the RMS load|
|0.1|
|voltage and at power factor of|SEER|30|40|50|60|70|80|
|current, Ib, in % of therated current.rated current.|
|15% are given in the electricalcharacteristics. For other|0.5|LI]PCR|]|amt|tT|Catalog Numbers|
|found by multiplying by voltages, the clearing I|[2]|t is|0.30.2|LAATAEE|1)|||tL|tL|EL|Catalog|CurrentRated|Electrical CharacteristicsI|[2]|t (A|[2]|Sec)Clearing|Watts|
|correction factor, K, given as a|ACCEL|2)|Numbers|RMS-Amps|Pre-arc|at 500V|Loss|
|function of applied working|0.15|PLETE|EET|TT|Eg|FWH-35BFWH-40B|3540|3476|150320|87.5|
|voltage, Eg, (rms).|100|250|400|500|FWH-45B|45|105|450|7.5|
|1) 35-800A Range|
|2) 1000-1600A Range|FWH-50B|50|135|670|7.5|
|FWH-60B|60|210|900|9.9|
|FWH-70B|70|210|900|10.6|
|Dimensions - in|
|FWH-80B|80|305|1400|12.7|
|FWH-90B|90|360|1600|15|
|Range|Fig.|A|B|C|D|E|F|G|H|J|
|-6060|1|3.188|0.813|1.593|2.541|2.193|0.344|0.719|0.125|0.518|FWH-100B|100|475|2000|17|
|-100100|1|3.625|0.947|1.736|2.853|2.807|0.352|0.750|0.125|0.375|FWH-125B|125|800|3500|25|
|-200200|1|3.625|1.156|1.836|2.892|2.768|0.344|1.000|0.188|0.406|FWH-150B|150|1100|4600|30|
|-400400|1|4.340|1.500|2.090|3.440|2.750|0.410|1.000|0.250|0.750|FWH-175B|175|1450|6200|35|
|-600600|1|4.340|2.000|2.090|3.530|2.780|0.410|1.500|0.250|0.780|FWH-200B|200|1900|8500|40|
|-800800|1|6.340|2.500|2.090|4.970|3.440|0.530|2.000|0.380|1.300|FWH-225A|225|4600|23300|39|
|-12001200|1|6.969|3.000|3.219|5.465|4.475|0.625|2.375|0.438|1.120|FWH-250A|250|6300|32200|41|
|-16001600|2|See Drawing|FWH-275A|275|7900|40300|46|
|FWH-300A|300|9800|49800|51|
|1mm = 0.0394” / 1” = 25.4mm|
|FWH-325A|325|13700|63800|53|
|FWH-350A|350|14500|72900|58|
|Fig. 1: 35-1200A|FWH-400A|400|19200|96700|65|
|A|FWH-450A|450|24700|127000|74|
|D|FWH-500A|500|29200|149000|84|
|E|
|C|H|FWH-600A|600|41300|206000|108|
|(<——|——»|"||ae|FWH-700A|700|55000|298000|120|
|FWH-800A|800|76200|409000|129|
|G|F|B|FWH-1000A|1000|92000|450000|145|
|a|FWH-1200A|1200|122000|600000|180|
|fee|l|jekk|J|e|r|\|FWH-1400A|1400|200000|1000000|210|
|Fig. 2: 1400-1600A|1|0.219|FWH-1600A|1600|290000|1400000|230|
|• Watts loss provided at rated current. • See accessories on page 141.|
**----- End of picture text -----**<br>
## **Total Clearing I[[2]] t**
**==> picture [259 x 264] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Amp|
|Range|Fig.|A|B|C|D|E|F|G|H|J|
|35-6060|1|3.188|0.813|1.593|2.541|2.193|0.344|0.719|0.125|0.518|
|70-100100|1|3.625|0.947|1.736|2.853|2.807|0.352|0.750|0.125|0.375|
|125-200200|1|3.625|1.156|1.836|2.892|2.768|0.344|1.000|0.188|0.406|
|225-400400|1|4.340|1.500|2.090|3.440|2.750|0.410|1.000|0.250|0.750|
|450-600600|1|4.340|2.000|2.090|3.530|2.780|0.410|1.500|0.250|0.780|
|700-800800|1|6.340|2.500|2.090|4.970|3.440|0.530|2.000|0.380|1.300|
|1000-12001200|1|6.969|3.000|3.219|5.465|4.475|0.625|2.375|0.438|1.120|
|1400-16001600|2|See Drawing|
|1mm = 0.0394” / 1” = 25.4mm|
|Fig. 1: 35-1200A|
|A|
|D|
|E|
|C|H|
|(<——|——»|"||ae|
|G|F|B|
|a|
|fee|l|jekk|J|e|r|\|
|Fig. 2: 1400-1600A|
|1|0.219|
|0.125|0.5|3.219|0.625|
|See|1.625|
|1.750|
|3.5|
|F|lee|O|O|o|ot|
|1|||e|2|©|o|——*|
|0.75|
|6.219|4.25|
|a|8.969|ee|
**----- End of picture text -----**<br>
## **Features and Benefits**
## **Typical Applications**
- Excellent DC performance
- DC Common bus
- Low arc voltage and low energy let-through (I[2] t)
- DC Drives
- Power converters/rectifiers
- Superior cycling capability
- Reduced voltage starters
## **Data Sheet: 720007**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**132**
**High Speed Fuses**
## **North American — FWH 500V: 35-1600A**
## **FWH 35-200A(B) & 900-1600A(A): 500V**
## **FWH 250-800A: 500V**
## **Time-Current Curve**
## **Time-Current Curve**
**==> picture [523 x 375] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4] 10 [3]<br>6<br>4<br>2<br>10 [3]<br>6 10 [2]<br>4<br>2 FWH-300A<br>FWH-400A<br>10 [2] FWH-500A<br>FWH-600A<br>6 FWH-800A<br>4<br>10 [1]<br>2 FWH-900A<br>FWH-1000A<br>10 [1] FWH-1200A<br>6 FWH-1400A<br>4 FWH-1600A<br>2<br>10 [0]<br>10 [0] FWH-80B<br>6 FWH-90B<br>4 FWH-100B<br>FWH-125B<br>2 FWH-35B FWH-150B<br>FWH-40B FWH-175B<br>10 [–1] 6 FWH-45BFWH-50B FWH-200B 10 [–1]<br>4 FWH-60B<br>FWH-70B<br>2<br>10 [–2]<br>6<br>4 10 [–2]<br>2<br>10 [–3]<br>6<br>4<br>2 10 [–3]<br>10 [–4]<br>2 4 6 8 2 4 6 8 2 4 6 8<br>10 [2] 10 [3] 10 [4]<br>Prospective Current In Amps RMS<br>10 [–4]<br>10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
## **Peak Let-Through Curve**
**==> picture [523 x 206] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [5] 10 [5]<br>FWH-1600A B<br>6 FWH-1400A<br>FWH-1200A<br>4 FWH-1000A<br>2<br>10 [4] 10 [4]<br>6<br>4 FWH-800AFWH-600A<br>FWH-500A<br>FWH-400A<br>2 FWH-300AFWH-250A<br>10 [3] 10 [3]<br>FWH-200B<br>6 FWH-150B<br>FWH-125B<br>4 FWH-100B A<br>FWH-80B<br>FWH-60B<br>2 FWH-50B<br>FWH-40B<br>FWH-35B<br>10 [2] 10 [2]<br>2 4 6 2 4 6 2 4 6 2 10 [2] 10 [3] 10 [4] 10 [5]<br>10 [2] 10 [3] 10 [4] 10 [5] Prospective Short-Circuit Current Symmetrical RMS<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current Peak Let-Through Current<br>**----- End of picture text -----**<br>
## **Data Sheet: 360**
**Data Sheet: 35785304**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**133**
**High Speed Fuses**
## **North American — KAC 600V: 1-1000A**
## **KAC**
## **Specifications**
**Description:** North American style stud-mount fuses. These 600V fuses are supplied as replacements only. For new installations, Bussmann recommends the 700V FWP Series fuse.
**Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts:— 600Vac
Amps:— 1-1000A
IR:— 200kA RMS Sym.
**Agency Information:** CE, UL Recognition JFHR2.E56413 on 1-600A only.
## **Catalog Numbers (Amps)**
|KAC-1|KAC-25|KAC-175|
|---|---|---|
|KAC-2|KAC-30|KAC-200|
|KAC-3<br>KAC-4<br>KAC-5|KAC-35<br>KAC-40<br>KAC-45|KAC-225<br>KAC-250<br>KAC-300|
|KAC-6|KAC-50|KAC-350|
|KAC-7|KAC-60|KAC-400|
|KAC-8|KAC-70|KAC-450|
|KAC-9<br>KAC-10|KAC-80<br>KAC-90|KAC-500<br>KAC-600|
|KAC-12|KAC-100|KAC-700|
|KAC-15<br>KAC-17.5|KAC-110<br>KAC-125|KAC-800<br>KAC-1000|
|KAC-20|KAC-150||
• See accessories on page 141.
## **Features and Benefits**
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- Power converters/rectifiers
- Reduced voltage starters
## **Dimensions - in**
|**Range**<br>1-30A|**Fig.**<br>1|**A**<br>2.875|**B1**<br>2.500|**B2**<br>–|**B3**<br>–|**C**<br>1.875|**D**<br>0.406|**E**<br>–|**F**<br>0.563|**G**<br>0.063|**H**<br>0.257|
|---|---|---|---|---|---|---|---|---|---|---|---|
|35-60A|2|4.375|–|3.750|3.500|2.750|0.625|0.343|0.813|0.094|0.468|
|70-100A|2|5.000|–|4.063|3.656|2.750|0.750|0.406|1.000|0.125|0.609|
|110-200A|2|5.140|–|4.390|3.766|2.906|1.000|0.406|1.500|0.188|0.718|
|225-400A|2|6.182|–|4.815|4.565|3.000|1.625|0.562|2.000|0.250|0.687|
|450-800A|1|6.250|4.750|–|–|3.063|2.000|–|2.500|0.250|0.563|
|1000A|1|7.250|4.750|–|–|3.063|2.750|–|3.500|0.375|0.563|
1mm = 0.0394˝ / 1˝ = 25.4mm
Fig. 1: 1-30 & 450-1000A
**==> picture [247 x 202] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>B1<br>C G<br>i, Zs<br>D F<br>[ee H<br>Fig. 2: 35-400A<br>A<br>B2<br>B3<br>C G<br>D E F<br>H<br>**----- End of picture text -----**<br>
**Data Sheet: 720009**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**134**
**High Speed Fuses** yy yyy
## **North American — KBC 600V: 35-800A**
## **KBC**
## **Specifications**
**Description:** North American style stud-mount and flush-end fuses. These 600V fuses are supplied as replacements only. For new installations, Bussmann recommends the 700V FWP Series fuse.
**Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts: — 600Vac Amps: — 35-800A
IR: — 200kA RMS Sym.
## **Catalog Numbers (Amps)**
|KBC-35<br>KBC-100|KBC-300|
|---|---|
|KBC-40<br>KBC-110|KBC-350|
|KBC-45<br>KBC-125<br>KBC-50<br>KBC-150<br>KBC-60<br>KBC-175|KBC-400<br>KBC-450<br>KBC-500|
|KBC-70<br>KBC-200|KBC-600|
|KBC-80<br>KBC-225<br>KBC-800<br>KBC-90<br>KBC-250<br>• See accessories on page 141.<br>**Features and Benefits**<br>•Low arc voltage and low energy let-through (I<br>~~ee~~||
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- Power converters/rectifiers
- Reduced voltage starters
**Agency Information:** CE, UL Recognition JFHR2.E56412 on 35-600A only.
## **Dimensions - in**
## **Amp**
|**Amp**|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**Range**|**Fig. **|**A**|**B**|**C**|**D**|**E**|**F**|**G**<br>**H**|**H**|**I**|
|**Range**<br>35-60A|**Fig.**<br>1|4.375|3.750|3.500|2.750|0.343|0.625|0.813 0.094|0.094|0.468|
|70-100A|2|See Drawing|||||||||
|110-200A|1|See Drawing<br>4.406|See Drawing<br>3.719|3.594|2.906|0.312|0.875|1.219 0.187|0.187|0.375|
|225-400A|1|5.125|4.188|3.563|2.906|0.406|1.000|1.500 0.250|0.250|0.719|
|450-600A|1|5.125|4.389|3.687|2.875|0.406|1.500|2.000 0.250|0.250|0.757|
|800A|3|See Drawing|||||||||
1mm = 0.0394” / 1” = 25.4mm
Fig. 1: 35-60 and 110-600A
A B C E D H F G ~~ue~~ I ~~L~~ O Fig. 2: 70-100A ~~——~~ w ~~a~~ e ~~‘~~ Te ~~l~~ J ~~e~~ l Fig. 3: 800A 4.000 3.750 ‹/•" - 24 ≈ ⁄/™" ~~|~~ ° 0.750 2.500 2.859 [ ~~LL ©:~~ 0.750
**Data Sheet: 720010**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**135**
**High Speed Fuses**
## **North American — FWP 700V: 5-1200A**
## **FWP**
## **Specifications**
**Description:** North American style stud-mount fuses. **Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts: — 700Vac/dc
Amps: — 5-1200A
IR: — 200kA RMS Sym. — 50kA @700Vdc
**Agency Information:** CE, UL Recognition JFHR2.E91958 FWP-_B (5-100A, 700-1200A), JFHR2.E56412 FWP-_A (125-600A) & CSA Component Acceptance file Class 1422-30, (53787) on 5-800A
**Electrical Characteristics** 1.5 K {========= **Total Clearing I[2] t** 1.0 BEES SS The total clearing I[2] t at rated =ss-—S7ee5 2) voltage and at power factor of 0.5 eT [| 15% are given in the electrical LtTey[yet characteristics. For other 1) 0.3 ple[aneeeen] Tt tt found by multiplying by voltages, the clearing I[2] t is 0.2 rAtLiYTtt 3) tT **t** t correction factor, K, given as 0.15 FELT EELttLLtt| Eg a function of applied working 316 460 604 700 1) 35-100A Range voltage, Eg, (rms). 2) 125-600A Range 3) 700-1200A Range
## **Dimensions - in**
|**Amp**||||||||||
|---|---|---|---|---|---|---|---|---|---|
|**Range**|**Fig.**<br>~~a~~|**Fig.**<br>**A**<br>~~a~~<br>~~es~~|**B**<br>~~es~~|**C**<br>~~es~~|**D**<br>~~es~~|**E**<br>~~es~~<br>~~es~~|**F**<br>~~eses~~|**G**|**H**<br>**I**|
|**Range**<br>5-30|**Fig.**<br>1<br>~~a~~<br>~~a~~|**Fig.**<br>2.870<br>~~a~~<br>~~es~~<br>~~a~~<br>~~es~~|0.563<br>~~es~~<br>~~es~~|1.855 <br>~~es~~<br>~~es~~|2.477<br>~~es~~<br>~~es~~|2.477<br>2.477 <br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~|0.250 0.405<br>~~eses~~<br>~~eses~~|0.405 0.063|0.063 0.250|
|35-60|1<br>~~a~~<br>~~a~~<br>~~a~~|4.375<br>~~a~~<br>~~es ~~<br>~~a~~<br>~~es~~<br>~~a~~<br>~~es~~|0.813<br> ~~es~~<br>~~es~~<br>~~es~~|2.750 <br>~~es~~<br>~~es~~<br>~~es~~|3.708<br>~~es~~<br>~~es~~<br>~~es~~|3.708<br>3.312 <br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~|0.344 0.725<br>~~es es~~<br>~~eses~~<br>~~eses~~|0.725 0.125|0.125 0.542|
|70-100|1<br>~~a~~<br>~~a~~<br>~~a~~|4.406<br>~~a~~<br>~~es ~~<br>~~a~~<br>~~es~~<br>~~a~~<br>~~es~~|0.947<br> ~~es~~<br>~~es~~<br>~~es~~|2.594 <br>~~es~~<br>~~es~~<br>~~es~~|3.625<br>~~es~~<br>~~es~~<br>~~es~~|3.625<br>3.563 <br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~|0.344 0.750<br>~~es es~~<br>~~eses~~<br>~~eses~~|0.750 0.125|0.125 0.375|
|125-200|1<br>~~a~~<br>~~a~~<br>~~a~~|5.090<br>~~a~~<br>~~es ~~<br>~~a~~<br>~~es~~<br>~~a~~<br>~~es~~|1.500<br> ~~es~~<br>~~es~~<br>~~es~~|2.840 <br>~~es~~<br>~~es~~<br>~~es~~|4.190<br>~~es~~<br>~~es~~<br>~~es~~|4.190<br>3.500 <br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~|0.410 1.000<br>~~es es~~<br>~~eses~~<br>~~eses~~|1.000 0.250|0.250 0.750|
|225-400|1<br>~~a~~<br>~~a~~<br>~~a~~|5.090<br>~~a~~<br>~~es ~~<br>~~a~~<br>~~es~~<br>~~a~~<br>~~es~~|2.000<br> ~~es~~<br>~~es~~<br>~~es~~|2.840 <br>~~es~~<br>~~es~~<br>~~es~~|4.280<br>~~es~~<br>~~es~~<br>~~es~~|4.280<br>3.530 <br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~|0.410 1.500<br>~~es es~~<br>~~eses~~<br>~~eses~~|1.500 0.250|0.250 0.780|
|450-600|1<br>~~a~~<br>~~a~~<br>~~pf-—_t~~|7.090<br>~~a~~<br>~~es ~~<br>~~a~~<br>~~es~~<br>~~pf-—_t~~|2.500<br> ~~es~~<br>~~es~~<br>~~pf-—_tff~~|2.840 <br>~~es~~<br>~~es~~<br>~~ff~~|5.720<br>~~es~~<br>~~es~~<br>~~ff~~|5.720<br>4.190 <br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~ff~~|0.530 2.000<br>~~es es~~<br>~~eses~~|2.000 0.380|0.380 1.300|
|700-800|1<br>~~a~~<br>~~pf-—_t~~|6.630<br>~~a~~<br>~~es ~~<br>~~pf-—_t~~|2.000<br> ~~es~~<br>~~pf-—_tff~~|2.844 <br>~~es~~<br>~~ff~~|5.562<br>~~es~~<br>~~ff~~|5.562<br>5.062 <br>~~es~~<br>~~es~~<br>~~ff~~|0.625 1.500<br>~~es es~~|1.500 0.250|0.250 0.875|
|900-1000|1000 2<br>~~pf-—_t~~|See Drawing<br>~~pf-—_tff~~||||||||
|1200|3<br>~~pf-—_t~~<br>~~[|~~|See Drawing<br>See Drawing<br>~~pf-—_t ff~~<br>~~[|~~||||||||
**==> picture [243 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fig. 1: 5-800A Fig. 2: 900-1000A Fig. 3: 1200A<br>3.500<br>1.375<br>J 0.125<br>f[0o a it [so 0.500 t<br>9.590 6.840 3.844<br>5.966 3.844 10.844<br>A M D n E C |) 7.594 5.154 ty cd o l<br>1.031 0.625<br>1.625<br>0.625 1.750<br>K t aTahle 2.750 e 0.750<br>“ TO F V e 0.5 4.250<br>~ G 3.500 Kt T A N ,<br>H ' @&<br>B<br>_ (o x e<br>**----- End of picture text -----**<br>
## **Arc Voltage**
**==> picture [245 x 249] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 2<br>UL<br>This curve gives the peak arc 1.6 —-<br>voltage, UL, which may 1.41.2 [|ee|ldee ee<br>appear across the fuse 10 [3] ae 1) eeae<br>during its operation as afunction of the applied 8 L_—_——————[| 2) |{ [{|]<br>working voltage, Eg, (rms) at 65<br>a power factor of 15%. 4 Pf fT<br>Power Losses 3 Eg<br>Watts loss at rated current is 300 400 500 600 700<br>1) 125-600A Range<br>given in the electrical 2) 35-100 & 700-1200A Range<br>characteristics. The curve<br>1.0<br>allows the calculation of the 0.8 EEE Kp<br>currents lower than the ratedpower losses at load power losses at load 0.60.5 SERS<br>0.4 Ft | | ¥ I | |<br>current. The correction factor,<br>0.3 FiT tTYi}[i]<br>Kp, is given as a function of<br>the RMS load current, Ib, in 0.2 TALE<br>% of the rated current.<br>TAT<br>0.1 ALLELE Ib<br>30 40 50 60 70 80 90 100%<br>**----- End of picture text -----**<br>
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the currents lower than the ratedpower losses at load power losses at load current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
## **Catalog Numbers**
|**Catalog Numbers**<br>**Catalog**<br>**Numbers**|**Catalog Numbers**<br>**Electrical Characteristics**|**Catalog Numbers**<br>**Electrical Characteristics**|**Catalog Numbers**<br>**Electrical Characteristics**|**Catalog Numbers**<br>**Electrical Characteristics**|
|---|---|---|---|---|
||**Rated**<br>**Current**<br>**RMS-Amps**|**Electrical Characteristics**<br>**I2t (A2 Sec)**||**Watts**<br>**Loss**|
|||**Pre-arc**|**Clearing**<br>**at 700V**||
|FWP-5B<br>FWP-10B<br>FWP-15B<br>FWP-20B<br>FWP-25B<br>FWP-30B<br>FWP-35B<br>FWP-40B<br>FWP-50B<br>FWP-60B<br>FWP-70B<br>FWP-80B<br>FWP-90B<br>FWP-100B<br>FWP-125A<br>FWP-150A<br>FWP-175A<br>FWP-200A<br>FWP-225A<br>FWP-250A<br>FWP-300A<br>FWP-350A<br>FWP-400A<br>FWP-450A<br>FWP-500A<br>FWP-600A<br>FWP-700A<br>FWP-800A<br>FWP-900A<br>FWP-1000A<br>FWP1200A|**Amps**<br>5<br>10<br>15<br>20<br>25<br>30<br>35<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>125<br>150<br>175<br>200<br>225<br>250<br>300<br>350<br>400<br>450<br>500<br>600<br>700<br>800<br>900<br>1000<br>1200|1.6<br>3.6<br>10<br>26<br>44<br>58<br>34<br>76<br>135<br>210<br>305<br>360<br>415<br>540<br>1800<br>2900<br>4200<br>5500<br>7700<br>10500<br>17600<br>23700<br>31000<br>36400<br>45200<br>66700<br>54000<br>78000<br>91500<br>120000<br>195000|10<br>20<br>75<br>180<br>340<br>450<br>160<br>320<br>600<br>950<br>2000<br>2400<br>2700<br>3500<br>7300<br>11700<br>16700<br>22000<br>31300<br>42500<br>71200<br>95600<br>125000<br>137000<br>170000<br>250000<br>300000<br>450000<br>530000<br>600000<br>1100000|1.5<br>4<br>5.5<br>6<br>7<br>9<br>12<br>12<br>12<br>15.5<br>18<br>21<br>25<br>27<br>28<br>32<br>35<br>43<br>45<br>48<br>58<br>65<br>78<br>94<br>107<br>122<br>125<br>140<br>150<br>170<br>190|
• Watts loss provided at rated current. • See accessories on page 141.
## **Features and Benefits**
## **Typical Applications**
- Excellent DC performance
- DC Common bus
- Low arc voltage and low energy let-through (I[2] t)
- DC Drives
- Superior cycling capability • Power converters/rectifiers
- Reduced voltage starters
## **Data Sheet: 720012**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**136**
**High Speed Fuses**
## **North American — FWP 700V: 5-1200A**
## **FWP 5-30A(B): 700V**
## **Time-Current Curve**
**==> picture [252 x 312] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>10 [2]<br>6<br>4<br>2<br>10 [1]<br>6<br>4<br>2<br>10 [0]<br>6<br>4 FWP-5B<br>FWP-10B<br>2 FWP-15B<br>FWP-20B<br>10 [–1] FWP-25B<br>6 FWP-30B<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4] 2 4 6 8 10 [1] 2 4 6 8 10 [2] 2 4 6 8 103<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
## **FWP 35-100A(B) & 700-1200A(A): 700V**
## **Time-Current Curve**
**==> picture [253 x 307] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>FWP-700A<br>10 [2] FWP-800A<br>6 FWP-900A<br>4 FWP-1000A<br>FWP-1200A<br>2<br>10 [1]<br>6 FWP-35B<br>4 FWP-40B<br>2 FWP-50B<br>FWP-60B<br>10 [0] FWP-70B<br>6 FWP-80B<br>4 FWP-90B<br>FWP-100B<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>2 4 6 8 10 [2] 2 4 6 8 10 [3] 2 4 6 8 104<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [523 x 232] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4] 10 [6]<br>FWP-1200A<br>6 6 FWP-1000A<br>4 FWP-800A<br>4 FWP-700A<br>2<br>FWP-30BFWP-25B 2<br>10 [3]<br>6 10 [4]<br>4<br>6<br>2 4<br>FWP-20B<br>FWP-15B<br>10 [2] FWP-10BFWP- 5B 2<br>6<br>4 10 [3]<br>2 6<br>FWP-100B<br>10 [1] 4 FWP-70B<br>10 [1] 2 4 6 10 [2] 2 4 6 10 [3] 2 4 6 10 [4] 2 4 6 10 [5] 2 FWP-60B<br>Prospective Short-Circuit Current 2 FWP-50B<br>FWP-40B<br>FWP-35B<br>10 [2]<br>2 4 6 2 4 6 2 4 6 2<br>10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current<br>Peak Let-Through Current<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Data Sheet: 35785316**
**Data Sheet: 35785308**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**137**
**High Speed Fuses**
## **North American — FWP 700V: 5-1200A**
## **FWP 150-600A: 700V**
## **Time-Current Curve**
**==> picture [252 x 331] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [3]<br>10 [2]<br>FWP-150A<br>FWP-200A<br>FWP-300A<br>10 [1] FWP-400A<br>FWP-600A<br>10 [0]<br>10 [–1]<br>10 [–2]<br>10 [–3]<br>10 [–4]<br>10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Current In Amperes RMSProspective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [252 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [5]<br>B<br>10 [4]<br>FWP-600A<br>FWP-400A<br>FWP-300A<br>FWP-200A<br>FWP-150A<br>10 [3]<br>A<br>10 [2]<br>10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
## **Data Sheet: 361**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**138**
**High Speed Fuses**
## **North American — FWJ 1000V: 35-2000A**
## **FWJ**
## **Arc Voltage**
**Arc Voltage** 2000 **Specifications** This curve gives the peak arc 1600 UL **Description:** North American ry voltage, UL, which may ~~ALL~~ style stud-mount fuses. appear across the fuse 1200 — during its operation as a ~~AL~~ **Dimensions:** See Dimensions function of the applied 800 illustration. -FWJ-300A ~~ALLELE~~ working voltage, Eg, (rms) **Ratings:** at a power factor of 15%. 400 Volts: — 1000Vac/800Vdc Eg 8) **Power Losses** ALLL TT Amps: — 35-2000A KJ TELE 200 600 ETI 1000 1400 1800 IR: — 25kA (35-200A) Watts loss at rated current is — 100kA (250-2000A) read given in the electrical characteristics. The curve 1.00.8 SESS Kp — 50kA @ 800Vdc allows the calculation of the 0.6 (35-200A, 450-600A) 0.5 power losses at load **Agency Information:** CE, UL 10ae| currents lower than the 0.4 SERPt | |yt Recognition JFHR8.E91958 on rated current. The 0.3 || | Yt | | 35-600A only. correction factor, Kp, is 0.2 EYEE| given as a function of the **Electrical Characteristics** RMS load current, Ib, in % ATH of the rated current. 0.1 ALE Ib **Total Clearing I[2] t** 1.5 30 40 50 60 70 80 90 100% voltage and at power factor ofThe total clearing I[2] t at rated 1.0 REESE K **Catalog NumbersRated Electrical CharacteristicsI2t (A2 Sec)** 15% are given in the electrical **Catalog Current Clearing Watts** characteristics. For other **Numbers RMS-Amps Pre-arc at 1000V Loss** voltages, the clearing I[2] t is 0.5 [bri| | tt tt FWJ-35AFWJ-40A 3540 210300 20002500 78 found by multiplying by Pitt FWJ-50A 50 470 3500 10 0.3 correction factor, K, given asa function of applied working 0.2 PTPt **t** tT TTTT| tT tTtttt|tt TTI FWJ-60AFWJ-70AFWJ-80A 607080 15501100670 690050009700 121311 voltage, Eg, (rms). 0.15 PLETE ETT TT Eg FWJ-90A 90 1900 12000 14 200 500 800 1000 FWJ-100A 100 2800 17500 15 FWJ-125A 125 4800 35000 16 FWJ-150A 150 6300 45000 25 **Dimensions - in** FWJ-175A 175 7500 65000 30 **Amp** FWJ-200A 200 11700 80000 32 **Range Fig. A B C D E F G H I** FWJ-250A 250 16000 112000 50 35-60 ~~Ge~~ 1 5.000 0.940 3.110 4.235 4.180 0.352 0.750 0.125 0.380 FWJ-300A 300 23500 164000 56 70-100 1 4.932 1.125 3.085 4.266 4.156 0.352 1.000 0.188 0.407 FWJ-350A 350 33000 231000 62 125-200 1 5.685 1.526 3.261 4.803 4.055 0.445 1.000 0.250 0.819 FWJ-400A 400 47000 330000 67 250-400 ~~Ge~~ 1 5.768 2.000 3.500 4.811 4.150 0.433 1.500 0.250 0.764 FWJ-500A 500 39500 329000 95 500-600 ~~Ge~~ 1 7.201 2.500 3.465 5.984 4.706 0.562 2.000 0.375 1.201 FWJ-600A 600 61000 520000 105 800-2000 ~~a~~ 1 6.811 3.500 3.312 5.472 4.962 0.625 2.750 0.500 0.880 FWJ-800A 800 87000 500000 182 1mm = 0.0394” / 1” = 25.4mm FWJ-1000A 1000 190000 1100000 206 FWJ-1200A 1200 370000 2100000 240 Fig. 1: 35-2000A FWJ-1400A 1400 470000 2700000 248 A FWJ-1600A 1600 700000 4000000 267 D FWJ-1800A 1800 925000 5300000 239 E FWJ-2000A 2000 1330000 7600000 244 C H • Watts loss provided at rated current. ~~—‘<—_i~~ __, ~~.~~ ” ~~i~~ e ~~nt~~ • See accessories on page 141. **Features and Benefits** G F B • Excellent DC performance • ~~vel~~ Low arc voltage and low energy let-through (I[2] t) y* ~~fei~~ J aN • Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
**Data Sheet: 720027**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**139**
**High Speed Fuses**
## **North American — FWJ 1000V: 35-2000A**
## **FWJ 35-600A: 1000V**
## **Time-Current Curve**
## **FWJ 800-2000A: 1000V**
## **Time-Current Curve**
**==> picture [523 x 340] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4] 10 [4]<br>6 6<br>4 4<br>2 2<br>10 [3] 10 [3]<br>6 6<br>4 4<br>2 2<br>10 [2]<br>10 [2]<br>64 FWJ-200AFWJ-250A 64 FWJ-800A<br>FWJ-300A 2 FWJ-1000A<br>2 FWJ-350A FWJ-1200A<br>FWJ-400A 10 [1] FWJ-1400A<br>10 [1] 6 FWJ-500A 64 FWJ-1600AFWJ-1800A<br>4 FWJ-600A FWJ-2000A<br>2<br>2<br>10 [0]<br>10 [0] 6<br>6 4<br>4 2<br>2 10 [–1]<br>10 [–1] 6<br>4<br>6<br>4 FWJ-40A 2<br>FWJ-50A<br>2 FWJ-60A 10 [–2]<br>FWJ-70A 6<br>10 [–2] FWJ-80A 4<br>64 FWJ-90AFWJ-100A 2<br>2 FWJ-125A 10 [–3]<br>FWJ-150A 6<br>10 [–3] FWJ-175A 4<br>6 2<br>4<br>10 [–4]<br>2 2 4 6 8 10 [3] 2 4 6 8 10 [4] 2 4 6 8 105<br>10 [–4] 10 [2] 2 4 6 8 10 [3] 2 4 6 8 104 Prospective Current In Amperes RMSProspective Current in Amps<br>Prospective Current In Amps RMS Data Sheet: 35785309<br>Virtual Pre-Arcing Time In Seconds<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [271 x 226] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>FWJ-2000A<br>FWJ-1800A<br>10 [5] FWJ-1600A<br>FWJ-1400A<br>6 FWJ-1250AFWJ-1000A<br>FWJ-600A<br>4 FWJ-800A<br>FWJ-400A<br>FWJ-500A<br>FWJ-350A<br>2 FWJ-300AFWJ-250A<br>FWJ-200A<br>FWJ-175A<br>10 [4] FWJ-150A<br>FWJ-125A<br>FWJ-100A<br>6 FWJ-90A<br>FWJ-80A<br>4 FWJ-70AFWJ-60A<br>FWJ-50A<br>FWJ-40A<br>2<br>10 [3]<br>6<br>4<br>2<br>10 [2]<br>2 4 6 2 4 6 2 4 6 2 4 6<br>10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
## **Data Sheet: 35785303**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**140**
**High Speed Fuses**
## **North American Fuse Accessories**
## **Fuse Bases (Blocks)**
## **Modular Style**
Bussmann offers a comprehensive line of fuse bases that provide the user with design and manufacturing flexibility. Two identical half bases make up a Bussmann modular fuse base. These “split” units can be panel mounted any distance apart to accommodate any length fuse.
## **Stud Type (Not sold in pairs)**
The simpler design is the C5268 Series modular fuse base. With this design, the fuse terminal and cable (with termination) are mounted on the same stud, minimizing labor needed for installation. The stud type base is available in the configuration shown in the table below.
|**Catalog**|**Max Fuse**|**Stud**|**Stud Dia.**|
|---|---|---|---|
|**Number**|**Amp Rating**|**Height (in)**|**& Threads**|
|C5268-1|200|1.00|5⁄16˝-18|
|C5268-2|200|1.75|5⁄16˝-18|
|C5268-3|200|0.75|5⁄16˝-18|
|C5268-4|100|1.00|1⁄4˝-20|
|C5268-5|100|1.75|1⁄4˝-20|
## **Connector Type**
Bussmann also offers a modular style fuse base that utilizes a tin-plated connector (for wire termination and heat dissipation) and a plated-steel stud (for fuse mounting). The connector type fuse base is available in the configurations shown below. Consult Bussmann for additional product details.
|details.||||
|---|---|---|---|
|**Modular**|**Max**|**Max Fuse**|**Data Sheet**|
|**Base Style**|**Voltage**|**Amp Rating**|**Number**|
|1BS101|600|100|1206|
|1BS102|600|400|1207|
|1BS103|600|400|1208|
|1BS104|600|600|1209|
|BH-0xxx|700|100|1200|
|BH-1xxx|2500|400|1201|
|BH-2xxx|5000|400|1202|
|BH-3xxx|1250|700|1203|
Refer to page 306 for BH style holders.
## **Fixed Center Base Style**
Bussmann offers a comprehensive line of fixed mount style fuse bases under the trademark TRON[™] rectifier fuse blocks. The cable and fuse connections are similar to the stud type fuse base — both are mounted on the same stud. Consult Bussmann for complete product details.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**141**
**High Speed Fuses**
## **Square Body Fuses**
## **Introduction**
|**Application Information**|**Application Information**||**143-144**|
|---|---|---|---|
|**Volts**<br>**(IEC/UL)**|**Size**|**Class**|**Fuse Style**<br>**Page**|
|**(IEC/UL)**<br>690/700|000,00<br>~~|~~<br>~~|~~|aR<br>~~|~~|**Fuse Style**<br>**Page**<br>DIN 43 653<br>145-147|
|||aR<br>~~|~~<br>~~|~~<br>~~|~~|Flush End Contact<br>145-147|
|||aR<br>~~|~~<br>~~||~~<br>~~|~~|DIN 43 620<br>148-149|
||1*, 1, 2, 3<br>~~|~~<br>~~||~~<br>~~**|**~~|aR<br>~~||~~<br>~~||~~|DIN 43 653<br>150-151|
|||aR<br>~~|||~~|Flush End Contact<br>152-153|
|||aR<br>~~||~~<br>~~|~~<br>~~**|**~~|US Style<br>154-155<br>|
|||aR<br>~~|~~<br>~~**|**~~|US Style<br>French Style<br>156-157<br>|
|||aR<br>~~**|**|~~|French Style<br>Fuse Curves<br>158-159<br>~~|~~|
||1*, 2, 3<br><br>~~a~~|aR<br>~~|~~<br>~~a~~|DIN 43 620<br>160-162<br>~~|~~|
||4<br>~~a~~<br>~~a~~|aR<br>~~a~~<br>~~a~~|Flush End Contact<br>163-164|
||23, 24<br>~~a~~<br>~~a~~|aR<br>~~a~~<br>~~a~~|Flush End Contact<br>165-166|
||00, 1, 2, 3<br>~~a~~<br>~~a~~|aR<br>~~a~~<br>~~a~~|DIN 43 620<br>168-171|
|1000|00<br>~~a~~<br>~~a~~<br>~~|~~|aR<br>~~a~~<br>~~a~~<br>~~|~~|DIN 43 653<br>172-173|
||1*, 1, 2, 3<br>~~a~~<br>~~||~~<br>~~**|**~~|aR<br>~~a~~<br>~~||~~|DIN 43 653<br>174-175|
|||aR<br>~~|||~~|Flush End Contact<br>176-177|
|||aR<br>~~||~~<br>~~|~~<br>~~**|**~~|US Style<br>178-179|
|||aR<br>~~|~~<br>~~**|**~~|US Style<br>Fuse Curves<br>180-181|
||4<br>~~**|**~~<br>~~a~~<br>~~|~~|aR<br>~~**|**~~<br>~~a~~<br>~~ee~~<br>~~|~~|Flush End Contact<br>182-184|
||24<br>~~a~~<br>~~a~~<br>~~|~~|aR<br>~~a~~<br>~~a~~<br>~~ee~~<br>~~|~~|Flush End Contact<br>185-186|
|1250/1300|1*, 1, 2, 3<br>~~a~~<br>~~||~~<br>~~**|**~~|aR<br>~~a~~<br>~~ee~~<br>~~||~~|DIN 43 653<br>187-188|
|||aR<br>~~ee~~<br>~~|||~~|Flush End Contact<br>189-190|
|||aR<br>~~||~~<br>~~|~~<br>~~**|**~~|US Style<br>191-192|
|||aR<br>~~|~~<br>~~**|**~~|US Style<br>Fuse Curves<br>193-194|
||4<br>~~**|**~~<br>~~a~~|aR<br>~~**|**~~<br>~~a~~<br>~~ee~~|Flush End Contact<br>195-197|
||23<br>~~a~~<br>~~a~~|aR<br>~~a~~<br>~~a~~<br>~~ee~~|Flush End Contact<br>198-199|
|1000-2000|5<br>~~a~~<br>~~a~~|aR<br>~~a~~<br>~~ee~~<br>~~a~~|Flush End Contact<br>200|
|DC Fuses|~~a~~<br>~~|~~|~~a~~<br>~~|~~|201-211|
|**Accessories**|**Page**|
|---|---|
|Indicator System|212|
|Fuse Bases|213|
|**Square Body Fuse Ranges**|**Square Body Fuse Ranges**|**Square Body Fuse Ranges**||
|---|---|---|---|
|**Amps**|**Volts**|**AC**|**DC**|
|10-7500|690|X|—|
|50-1400|1250|X|—|
## **General Information**
Designed and tested to:
- IEC 60269: Part 4
- UL Recognized
Bussmann offers a complete range of square body style fuses and accessories. Their unique design and construction provide:
- Minimal energy let-through (I[2] t)
- Low operating temperature
- Low watts loss
Square body style fuses are a very attractive solution for high power applications which require a compact design with superior performance. The construction and design of square body style fuses make it easy for Bussmann to manufacture custom products. Our cataloged offering provides only a sample of the wide variety of product which is available.
Each square body style fuse is available with a number of different end fittings. Options include:
- DIN 43 653
- DIN 43 620
- Flush End (Metric/US)
- French Style
- US Style
## **Voltage Rating**
All Bussmann square body style fuses are tested to IEC 60269: Part 4. This standard requires a test voltage which is 5% higher than the rated voltage. In North America, fuses are required to clear only their rated voltage.
## **Accessories**
Square Body style fuses are available with three different open fuse indicator systems. Options include visual indication and indication utilizing a microswitch. Fuse blocks are also available for most applications.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**142**
**High Speed Fuses**
## **Square Body Applications**
## **Maximum Permissible Load Current**
The rated current value of Bussmann fuses is based on the ambient temperature in the space immediately below the fuse of 20°C. The following graph gives correction factors (k) for a range of temperatures (–40°C to +80°C). Maximum permissible continuous load currents can be calculated by applying the following formula:
**Ib** ≤ **In** ≈ **k** ≈ **(1 + 0.05 V) x Kb**
where
- **Ib = Maximum permissible continuous load current**
- **In = Rated current of fuse**
- **k = Temperature correction factor v = Velocity of cooling air in m/s (max. 5 m/s). Kb = Fuse load constant 1.0**
## **Temperature Correction Curve**
**==> picture [253 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
k<br>1.4<br>1.2<br>1<br>0.8<br>0.6<br>–40 –20 0 20 40 60 80 C<br>**----- End of picture text -----**<br>
The maximum permissible continuous load current Ib of a fuse can be checked empirically (i.e., by satisfying the formula below) by making simple voltage and temperature measurements under actual operating conditions after the fuse has been installed in its operating location and loaded at the calculated Ib value:
**E2** ≈ **(0.92 + 0.004t)** ≤ **N E1**
where
- **E1 = Voltage drop across fuse after 5 seconds E2 = Voltage drop across fuse after 2 hours**
- **t = Air temperature at start of test (°C)**
- **N = Constant**
|**Constant**||
|---|---|
|**Fuse Rated Voltage (IEC) **|**N**|
|690|1.5|
|1250|1.6|
> **[Body Cross Section ]** Standard fuse program includes barrels with different cross sections.
|**Size**|**000**|**00**|**1**|**1**|**2**|**3**|**4**|
|---|---|---|---|---|---|---|---|
|Maximum<br>Cross-section<br>(mm)|21 ≈ 36|30 ≈ 47|45 ≈ 45|53 ≈ 53|61 ≈ 61|76 ≈ 76|105 ≈ 105|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**143**
**High Speed Fuses**
## **Square Body Applications**
## **Example Application of Square Body High Speed Fuses Subject to Overload and Impulse Loading**
Select a short-blade indicating fuse with indicator/adapter to permit the use of a single-pole microswitch for remote indication and determine if the fuse selected will meet the following application parameters.
## **Application Parameters**
**Load Currents Expected**
|**Load Type**|**Duration**|**Frequency of Occurrence**|**Amps**|
|---|---|---|---|
|(1)Normal|Continuous|—|300A|
|(2)Overload|60 Seconds|Once Per Hour|500A|
|(3a)<br>(3b)Overload|10 Seconds<br>2-3 Times Per Week<br>20 Seconds(max.) Once Per Month||700A|
|(4)Impulse|0.5 Seconds|Less Than Once Per Month|1100A|
|**Voltage Data**||||
|(5) Voltage Applied to Fuse During Fault Conditions|||400V|
|(+10%)||||
## **Temperature Data**
(6) Temperature Inside Cubicle in Which Fuse is Located (Natural Convection Cooling Only) 60°C
## **Thyrister Data**
(7) Thyrister Peak Voltage Withstand 1000V (8) Thyrister I[2] t Withstand at 10 Milliseconds* 90,000A[2] s
*Note: The I[2] t withstand of the thyrister may be given for other impulse durations (i.e., 1.5 ms, 3.5 ms, or 8.3 ms); however, the stated fuse I[2] t is valid for all impulse durations of 10 ms or less.
## **Application Procedure**
|**Ste**|**p**<br>**Procedure**<br>**Remarks**|
|---|---|
|(1)<br>mo|Select a short-blade fuse to permit<br>1.1 Taking into consideration only the<br>unting of microswitch 170H0069<br>continuous load current and ambient<br>temperature, from Table on page 127<br>—<br>tentatively select fuse 170M3669<br>400A, 690V).|
|(2)|Determine I2t (total clearing) at 440V.<br>2.1 See Table, page 127. Note I2t is<br>105,000A2s at rated voltage of 690V.<br>2.2 From the figure on page 126, note that<br>OK<br>correction factor K = 0.65.<br>2.3 I2t660V ≈K = I2t440V<br>105,000≈0.65 = 68,250|
|(3)<br>at 4|Determine maximum arc voltage<br>3.1 From the figure on page 126, note that<br>40V<br>maximum voltage at 440V is 900V<br>OK|
|(4)<br>con|Determine maximum permissible<br>4.1 Per page 115 data,<br>tinuous load current Ib.<br>Ib = In ≈ k ≈ (1 + 0.05V) ≈ Kb<br>—<br>Ib = 400A ≈ 0.8 ≈ (1 + 0) ≈ 1<br>Ib = 320A|
|(5)<br>exp<br>Det<br>loa<br>ma<br>(Ite<br>(Ite<br>(Ite<br>(Ite|Plot a “line profile” showing the<br>5.0 Calculate Imax per Table,<br>ected load and overload currents.<br>High Speed Fuse Application Guide<br>—<br>ermine that overload and impulse<br>page 16, for each overload and impulse<br>d currents do not exceed their<br>load.<br>ximumpermissible values.|
||m 2)<br>5.1Imax < 60% ≈ It<br>500A < 60%≈950A<br>OK<br>500A < 570A|
||m 3a)<br>5.2 Imax < 60% ≈ It<br>700A < 60% ≈ 1360A<br>OK<br>700A < 780A|
||m 3b)<br>5.3 Imax < 70% ≈ It<br>700A < 70% ≈ 1150A<br>OK<br>700A < 805A|
||m 4)<br>5.4 Imax < 70% ≈ It<br>1100A < 70% ≈ 1800A<br>OK<br>1100A < 1260A|
**==> picture [179 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
170M3669 (400A)<br>103<br>102<br>A A<br>101<br>10 [0]<br>10–1<br>10–2 102 103<br>Current In Amperes<br>Time In Seconds<br>Profile Line<br>**----- End of picture text -----**<br>
## **Calculation of Watt Loss**
From the Table on page 127, watt loss at 400 amps is 60 watts. The continuous load current of 300A is 75% of rated current (400A). From page 126, the correction factor Kp = 0.5.
Watt Loss 75% = Watt Loss 100% ≈ Kp = 60W ≈ 0.5 = 30 watts
## **Special Fuses**
Other high speed fuses are available from Bussmann with voltage ratings of 380 to 10,000V and current ratings up to 10,000A in a single unit configuration. Fuses can be supplied with open fuse, “pin” indicators. Various types of microswitches are also available (see page 212).
The tentatively selected fuse 170M3669 with microswitch 170H0069 meets all application parameters; no further selection would be necessary.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**144**
**High Speed Fuses** ee
## **Square Body DIN 43 653 — 690V/700V (IEC/UL): 10-400A**
## **690V/700V (IEC/UL) 10-400A**
## =
## **Specifications**
**Description:** Square body DIN 43-653 stud mount high speed fuses.
**Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 690Vac (IEC) — 700Vac (UL)
Amps: — 10-400A
IR: — 200kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2, CSA Certified: Class 53787, File 1422-30 on Size 000.
**Electrical Characteristics** 1.5 **Total Clearing I[2] t** K 1.0 ~~SERRE~~ The total clearing I[2] t at rated voltage and at power factor of 15% are given 0.5 ~~ee~~ in the electrical 0.4 ~~Ter~~ characteristics. For other 0.3 ~~~~] tT | tf~~ voltages, the clearing I[2] t is found by multiplying by 0.2 ~~PE tT~~ E correction factor, K, given ~~Pt~~ tT ~~ed~~ yt g as a function of applied 100 200 300 400 500 600 690
working voltage, Eg,(rms). (rms).
**==> picture [244 x 286] intentionally omitted <==**
**----- Start of picture text -----**<br>
working voltage, Eg,(rms). 1.41.2 UL<br>10 [3] ee<br>Arc Voltage 9<br>8<br>This curve gives the 7<br>peak arc voltage, UL, 6 =zene<br>which may appear 5 eT<br>across the fuse during<br>4<br>its operation as a Ey<br>E<br>function of the applied 3 g<br>working voltage, Eg, 200 FE 300 400 500 600 690<br>(rms) at a power factor of 15%.<br>1.0<br>K<br>0.8 p<br>Power Losses<br>0.6<br>a<br>Watts loss at rated 0.5<br>0.4 Pt | | yd] |<br>current is given in the<br>electrical characteristics. 0.3 PTTEEEYET TT<br>The curve allows the<br>0.2 | YA|<br>calculation of the power<br>losses at load currents<br>lower than the rated current. The correction 0.1 Ib<br>30 40 50 60 70 80 90 100%<br>factor, Kp, is given as a /CLELE<br>function of the RMS load current, Ib, in % of the rated<br>current.<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
## **Dimensions - mm**
|**Dimensions - mm**|||||
|---|---|---|---|---|
|Type-U/80,-/80,-TN/80|||||
|**Size**<br>**D**<br>**E**|**F**|**G**|**H**|**K**|
|000<br>40<br>21|20|51|8|2|
|00<br>51<br>30<br>1mm = 0.0394” / 1” = 25.4mm|28|67|10|2|
- DC Drives
- Power converters/rectifiers
## **For Other Voltage Ratings in This Body Style**
- See page 172 (1000V)
## **Dimensions (mm)**
**==> picture [484 x 163] intentionally omitted <==**
**----- Start of picture text -----**<br>
54 Type 00B/60, 00BTN/60<br>Indicator * 1mm = 0.0394” / 1” = 25.4mm<br>M8<br>D<br>K 6<br>lL , E fpi :<br>30 64<br>54 Max<br>G i 100 a<br>78<br>48<br>E H F 62<br>ao el ct<br>* Indication for Size 00 fuses is a red pin.<br>**----- End of picture text -----**<br>
Indicator
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**145**
**High Speed Fuses**
## **Square Body DIN 43 653 — 690V/700V (IEC/UL): 10-400A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**||||||
|---|---|---|---|---|---|---|---|---|---|
|<br>**Catalog Numbers**<br>|||||<br>**Size**|**Electrical Characteristics**||||
|**-U/80**<br>**Without**<br>**Indicator**|<br>**-/80**<br>**Visual**<br>**Indicator**|<br>**-TN/80**<br>**Type T**<br>**Indicator**<br>**for Micro**|**00B/60**<br>**Visual**<br>**Indicator**|**00BTN/60**<br>**Type T**<br>**Indicator**<br>**for Micro**||||||
|||||||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**||**Watts**<br>**Loss**|
||||||||<br>**Pre-arc**|<br>**Clearing**<br>**at 660V**||
|170M1308<br>170M1309<br>170M1310<br>170M1311<br>170M1312<br>170M1313<br>170M1314<br>170M1315<br>170M1316<br>170M1317<br>170M1318<br>170M1319<br>170M1320<br>170M1321<br>170M1322|170M1358<br>170M1359<br>170M1360<br>170M1361<br>170M1362<br>170M1363<br>170M1364<br>170M1365<br>170M1366<br>170M1367<br>170M1368<br>170M1369<br>170M1370<br>170M1371<br>170M1372|170M1408<br>170M1409<br>170M1410<br>170M1411<br>170M1412<br>170M1413<br>170M1414<br>170M1415<br>170M1416<br>170M1417<br>170M1418<br>170M1419<br>170M1420<br>170M1421<br>170M1422|||000|10<br>16<br>20<br>25<br>32<br>40<br>50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315|3.8<br>7.2<br>11.5<br>19<br>40<br>69<br>115<br>215<br>380<br>695<br>1200<br>2300<br>4200<br>7750<br>12000|25.5<br>48<br>78<br>130<br>270<br>460<br>770<br>1450<br>2550<br>4650<br>8500<br>16000<br>28000<br>51500<br>80500|3.0<br>5.5<br>7<br>9<br>10<br>12<br>15<br>16<br>19<br>24<br>28<br>32<br>37<br>42<br>52|
||170M2608<br>170M2609<br>170M2610<br>170M2611<br>170M2612<br>170M2613<br>170M2614<br>170M2615<br>170M2616<br>170M2617<br>170M2618<br>170M2619<br>170M2620<br>170M2621|170M2658<br>170M2659<br>170M2660<br>170M2661<br>170M2662<br>170M2663<br>170M2664<br>170M2665<br>170M2666<br>170M2667<br>170M2668<br>170M2669<br>170M2670<br>170M2671|170M2708<br>170M2709<br>170M2710<br>170M2711<br>170M2712<br>170M2713<br>170M2714<br>170M2715<br>170M2716<br>170M2717<br>170M2718<br>170M2719<br>170M2720<br>170M2721|170M2758<br>170M2759<br>170M2760<br>170M2761<br>170M2762<br>170M2763<br>170M2764<br>170M2765<br>170M2766<br>170M2767<br>170M2768<br>170M2769<br>170M2770<br>170M2771|00|25<br>32<br>40<br>50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400|19<br>28.5<br>50<br>95<br>170<br>310<br>620<br>1000<br>1900<br>3400<br>6250<br>10000<br>13500<br>18000|130<br>195<br>360<br>640<br>1200<br>2100<br>4150<br>6950<br>13000<br>23000<br>42000<br>68500<br>91500<br>125000|6<br>7<br>9<br>10<br>12<br>15<br>20<br>25<br>30<br>35<br>45<br>55<br>60<br>70|
- Watts loss provided at rated current.
- Microswitch indicator ordered separately.
- See accessories on pages 212-213.
- For fuse curves see page 147.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**146**
**High Speed Fuses**
## **Square Body Size 000, 00 — 690V/700V (IEC/UL): 10-400A**
## **Size 000 — 10-315A: 690V Time-Current Curve**
**==> picture [252 x 568] intentionally omitted <==**
**----- Start of picture text -----**<br>
104<br>103<br>102<br>A<br>101 A<br>10 [0]<br>10 [–1]<br>10 [–2]<br>10 [–3]<br>1x10 [–4]<br>1x10 [1] 10 [2] 10 [3] 10 [4]<br>Prospective Current In Amps RMS<br>Peak Let-Through Curve<br>104 315A 250A<br>B 200A160A<br>125A<br>100A<br>80A<br>63A<br>50A<br>40A<br>32A<br>25A<br>20A<br>10 [3] 16A<br>10A<br>10 [2]<br>A<br>2x10 [1]<br>1x10 [1] 10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>10A 16A 20A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 250A 315A<br>Virtual Pre-Arcing Time In Seconds<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
## **Size 00 — 25-400A: 690V Time-Current Curve**
**==> picture [253 x 560] intentionally omitted <==**
**----- Start of picture text -----**<br>
104<br>103<br>10 [2]<br>A<br>101 A<br>10 [0]<br>10–1<br>10 [–2]<br>10 [–3]<br>1x10–4 1x101 102 103 104<br>Prospective Current in Amps RMS<br>Peak Let-Through Curve<br>104 400A 350A 315A250A<br>B 200A<br>160A<br>125A<br>100A<br>80A<br>63A<br>50A<br>40A<br>32A<br>25A<br>10 [3]<br>10 [2]<br>A<br>2x10 [1]<br>1x10 [1] 10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 250A 315A 350A 400A<br>Virtual Pre-Arcing Time In Seconds<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Data Sheet: 172056312**
**Data Sheet: 17056310**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**147**
**High Speed Fuses**
## **Square Body DIN 43 620 — 690V (IEC/UL): 10-315A**
## **690V (IEC/UL) 10-315A**
## **Specifications**
**Description:** Square body DIN 43 620 blade style high speed fuses. **Dimensions:** See dimensions illustration.
**Ratings:**
## **Arc Voltage**
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of theapplied working voltage, Eg, (rms) at a power factor of 15%.
Volts: — 690Vac Amps: — 10-315A
IR: — 200kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2. & CSA Component Acceptance file Class 1422-30, (53787)
## **Electrical**
## **Characteristics**
## **Total Clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Power Losses**
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **Dimensions - mm**
**==> picture [250 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
DIN 000 Type T<br>1mm = 0.0394” / 1” = 25.4mm ‘«— 54 Max<br>Indicator<br>Ta<br>*<br>15<br>yy<br>48 79<br>+ 21 | 1, 6<br>4+ =<br>_— 35 —<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**148**
**High Speed Fuses**
## **Square Body DIN 43 620 — 690V (IEC/UL): 10-315A**
## **Catalog Numbers**
|**Catalog Numbers**|**Size**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|
|**DIN**<br>**Type T**<br>**Indicator**<br>**for Micro**||||||
|||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**||**Watts**<br>**Loss**|
||||**Pre-arc**|**Clearing**<br>**at 660V**||
|170M1558D<br>170M1559D<br>170M1560D<br>170M1561D<br>170M1562D<br>170M1563D<br>170M1564D<br>170M1565D<br>170M1566D<br>170M1567D<br>170M1568D<br>170M1569D<br>170M1570D<br>170M1571D|000|**Amps**<br>10<br>16<br>20<br>25<br>32<br>40<br>50<br>63<br>80<br>100<br>125<br>160<br>200<br>250|4<br>7<br>11.5<br>19<br>40<br>65<br>115<br>215<br>380<br>695<br>1180<br>2300<br>4350<br>7900|27<br>51<br>82.5<br>140<br>285<br>490<br>815<br>1550<br>2700<br>4950<br>8250<br>16500<br>31000<br>56000|2.5<br>4<br>5<br>6<br>7<br>8.5<br>9.5<br>11.5<br>15<br>16.5<br>21.5<br>25<br>29.5<br>35.5|
|170M1572D|00|315|12000|84500|45|
## **Size 000 — 10-315A: 690V**
## **Time-Current Curve**
- Watts loss provided at rated current.
• Microswitch indicator ordered separately. See accessories on pages 212-213.
## **Rated Current**
The rated current of this fuse range has been given with copper conductors that have a current density of 1.3A/mm[2] (IEC 60269-4). For conductor cross section according to IEC 60269-1, the fuses with a rated current higher than 125A must be derated. Please contact Bussmann for application assistance.
## **Peak Let-Through Curve**
**Data Sheet: 72056310**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**149**
**High Speed Fuses**
## **Square Body DIN 43 653 — 690V/700V (IEC/UL): 40-2000A**
## **690V/700V (IEC/UL) 40-2000A**
## **Arc Voltage**
**==> picture [249 x 260] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 1.41.2 UL a a<br>This curve gives the peak 10 [3] eee<br>arc voltage, UL, which 9<br>may appear across thefuse during its operation 876 Lr| 7,[ft| [[ff| |<br>working voltage, Eg, (rms)as a function of theapplied 5 Ane<br>at a power factor of 15%. 4<br>Teer<br>E<br>3 200 tt 300 400 | 500 600 i 690g<br>Power Losses 1.0<br>0.8 Kp<br>Watts loss at rated current SSS<br>0.6<br>is given in the electrical 0.5 Yr {| [ [| [A | |<br>characteristics. The curve 0.4 a<br>allows the calculation ofthe power losses at load 0.3 TEEYLL<br>currents lower than the 0.2 TALL<br>rated current. The OEE<br>correction factor, Kp, is<br>given as a function of the 0.1 ALL ELL Ib<br>RMS load current, Ib, in % 30 40 50 60 70 80 90 100%<br>of the rated current.<br>**----- End of picture text -----**<br>
## **Specifications**
Description: Square body DIN 43 653 stud-mount high speed fuses. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 690Vac (IEC)
— 700Vac (UL)
Amps: — 40-2000A
IR: — 200kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2, CSA Certified: Class 53787, File 1422-30.
## **Electrical Characteristics**
## **Total Clearing I[2] t**
**==> picture [118 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.5<br>K<br>2) 1)<br>1.0<br>ft}| |<br>==<br>0.5 | eT]<br>0.4 cet | | [|| ld| Cdof<br>0.3 FET<br>0.2 Baa<br>E<br>TELL g<br>100 200 300 400 500 600 690<br>1) Rated voltage 600V<br>2) Rated voltage 550V<br>**----- End of picture text -----**<br>
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **Dimensions - mm**
|**Size**<br>1*|**A**<br>50|**B**<br>104|**B****<br>134|**C**<br>78|**C****<br>108|**D*****<br>58|**E**<br>45|**H**<br>22|
|---|---|---|---|---|---|---|---|---|
|1|50|108|138|78|108|66|53|25|
|2|50|108|138|78|108|75|61|25|
|3|51|109|139|78|108|90|76|30|
## **For Other Voltage Ratings in This Body Style**
- See pages 174 (1000V) and 187 (1250V/1300V)
**Valid for fuses type -/110, -TN/110.
Type -KN/80, -KN/110
***Microswitch.
1mm = 0.0394” / 1” = 25.4mm
**==> picture [516 x 166] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>A<br>Type -/80, -TN/80, -/110, -TN/110.<br>C<br>> A i e =<br>H<br>= YY<br>+ o e H t 11 e<br>D<br>11<br>D E B<br>E my B f e = |<br>6<br>6<br>E<br>E<br>SL poy a.<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**150**
**High Speed Fuses**
## **Square Body DIN 43 653 — 690V/700V (IEC/UL): 40-2000A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**Catalog Numbers**||||||**Size**||**Electrical Characteristics**|||
|**-/80**<br>**Visual**<br>**Watts**<br>**Indicator**|**-TN/80**<br>**Type T**<br>**Indicator**<br>**for Micro**|**-KN/80**<br>**Type K**<br>**Indicator**<br>**for Micro**|**-/110**<br>**Visual**<br>**for Micro**|**-TN/110**<br>**Type T**<br>**Indicator**<br>**for Micro**|**-KN/110**<br>**Type K**<br>**Indicator**<br>**-KN/80**||||||
||||||||**Rated**<br>**RMS-Amps**|**I2t (A2 Sec)**||**Clearing**<br>**Loss**|
|||||||||**Current**<br>**Pre-arc**|**at 660V**||
|170M3008<br>170M3009<br>170M3010<br>170M3011<br>170M3012<br>170M3013<br>170M3014<br>170M3015<br>170M3016<br>170M3017<br>170M3018<br>170M3019<br>170M3020<br>170M3021<br>170M3022<br>170M3023|170M3058<br>170M3059<br>170M3060<br>170M3061<br>170M3062<br>170M3063<br>170M3064<br>170M3065<br>170M3066<br>170M3067<br>170M3068<br>170M3069<br>170M3070<br>170M3071<br>170M3072<br>170M3073|170M3108<br>170M3109<br>170M3110<br>170M3111<br>170M3112<br>170M3113<br>170M3114<br>170M3115<br>170M3116<br>170M3117<br>170M3118<br>170M3119<br>170M3120<br>170M3121<br>170M3122<br>170M3123|170M3158<br>170M3159<br>170M3160<br>170M3161<br>170M3162<br>170M3163<br>170M3164<br>170M3165<br>170M3166<br>170M3167<br>170M3168<br>170M3169<br>170M3170<br>170M3171<br>170M3172<br>170M3173|170M3208<br>170M3209<br>170M3210<br>170M3211<br>170M3212<br>170M3213<br>170M3214<br>170M3215<br>170M3216<br>170M3217<br>170M3218<br>170M3219<br>170M3220<br>170M3221<br>170M3222<br>170M3223|170M3258<br>170M3259<br>170M3260<br>170M3261<br>170M3262<br>170M3263<br>170M3264<br>170M3265<br>170M3266<br>170M3267<br>170M3268<br>170M3269<br>170M3270<br>170M3271<br>170M3272<br>170M3273|1*|40<br>50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630|40<br>77<br>115<br>185<br>360<br>550<br>1100<br>2200<br>4200<br>7000<br>10000<br>15000<br>21000<br>27000<br>34000<br>48500|270<br>515<br>770<br>1250<br>2450<br>3700<br>7500<br>15000<br>28500<br>46500<br>68500<br>105000<br>140000<br>180000<br>230000<br>325000|9<br>11<br>14<br>18<br>21<br>26<br>30<br>35<br>40<br>50<br>55<br>60<br>65<br>70<br>75<br>80|
|170M4008<br>170M4009<br>170M4010<br>170M4011<br>170M4012<br>170M4013<br>170M4014<br>170M4015<br>170M4016<br>170M4017<br>170M4018<br>170M4019|170M4058<br>170M4059<br>170M4060<br>170M4061<br>170M4062<br>170M4063<br>170M4064<br>170M4065<br>170M4066<br>170M4067<br>170M4068<br>170M4069|170M4108<br>170M4109<br>170M4110<br>170M4111<br>170M4112<br>170M4113<br>170M4114<br>170M4115<br>170M4116<br>170M4117<br>170M4118<br>170M4119|170M4158<br>170M4159<br>170M4160<br>170M4161<br>170M4162<br>170M4163<br>170M4164<br>170M4165<br>170M4166<br>170M4167<br>170M4168<br>170M4169|170M4208<br>170M4209<br>170M4210<br>170M4211<br>170M4212<br>170M4213<br>170M4214<br>170M4215<br>170M4216<br>170M4217<br>170M4218<br>170M4219|170M4258<br>170M4259<br>170M4260<br>170M4261<br>170M4262<br>170M4263<br>170M4264<br>170M4265<br>170M4266<br>170M4267<br>170M4268<br>170M4269|1|200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>‡900|1650<br>3100<br>6200<br>8500<br>13500<br>17000<br>25000<br>34000<br>52000<br>69500<br>105000<br>155000|11500<br>21000<br>42000<br>59000<br>91500<br>120000<br>170000<br>230000<br>350000<br>465000<br>725000<br>‡850000|45<br>55<br>58<br>60<br>65<br>70<br>72<br>75<br>80<br>85<br>95<br>100|
|170M5008<br>170M5009<br>170M5010<br>170M5011<br>170M5012<br>170M5013<br>170M5014<br>170M5015<br>170M5016<br>170M5017<br>170M5018|170M5058<br>170M5059<br>170M5060<br>170M5061<br>170M5062<br>170M5063<br>170M5064<br>170M5065<br>170M5066<br>170M5067<br>170M5068|170M5108<br>170M5109<br>170M5110<br>170M5111<br>170M5112<br>170M5113<br>170M5114<br>170M5115<br>170M5116<br>170M5117<br>170M5118|170M5158<br>170M5159<br>170M5160<br>170M5161<br>170M5162<br>170M5163<br>170M5164<br>170M5165<br>170M5166<br>170M5167<br>170M5168|170M5208<br>170M5209<br>170M5210<br>170M5211<br>170M5212<br>170M5213<br>170M5214<br>170M5215<br>170M5216<br>170M5217<br>170M5218|170M5258<br>170M5259<br>170M5260<br>170M5261<br>170M5262<br>170M5263<br>170M5264<br>170M5265<br>170M5266<br>170M5267<br>170M5268|2|400<br>450<br>500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250|11000<br>15500<br>21500<br>28000<br>41000<br>60500<br>86000<br>125000<br>180000<br>245000<br>365000|74000<br>105000<br>145000<br>190000<br>275000<br>405000<br>575000<br>840000<br>1250000<br>1600000<br>2400000|65<br>70<br>75<br>80<br>90<br>95<br>105<br>110<br>115<br>120<br>130|
|170M6008<br>170M6009<br>170M6010<br>170M6011<br>170M6012<br>170M6013<br>170M6014<br>170M6015<br>170M6016<br>170M6017<br>170M6018<br>170M6019<br>170M6020<br>170M6021|170M6058<br>170M6059<br>170M6060<br>170M6061<br>170M6062<br>170M6063<br>170M6064<br>170M6065<br>170M6066<br>170M6067<br>170M6068<br>170M6069<br>170M6070<br>170M6071|170M6108<br>170M6109<br>170M6110<br>170M6111<br>170M6112<br>170M6113<br>170M6114<br>170M6115<br>170M6116<br>170M6117<br>170M6118<br>170M6119<br>170M6120<br>170M6121|170M6158<br>170M6159<br>170M6160<br>170M6161<br>170M6162<br>170M6163<br>170M6164<br>170M6165<br>170M6166<br>170M6167<br>170M6168<br>170M6169<br>170M6170<br>170M6171|170M6208<br>170M6209<br>170M6210<br>170M6211<br>170M6212<br>170M6213<br>170M6214<br>170M6215<br>170M6216<br>170M6217<br>170M6218<br>170M6219<br>170M6220<br>170M6221|170M6258<br>170M6259<br>170M6260<br>170M6261<br>170M6262<br>170M6263<br>170M6264<br>170M6265<br>170M6266<br>170M6267<br>170M6268<br>170M6269<br>170M6270<br>170M6271|3|500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250<br>1400<br>1500<br>1600<br>†1800<br>‡2000|14000<br>19500<br>31000<br>44500<br>69500<br>100000<br>140000<br>190000<br>290000<br>370000<br>460000<br>580000<br>880000<br>1150000|95000<br>135000<br>210000<br>300000<br>465000<br>670000<br>945000<br>1300000<br>1950000<br>2450000<br>3100000<br>3900000<br>†5250000<br>‡6350000|95<br>100<br>105<br>110<br>115<br>120<br>125<br>130<br>140<br>155<br>160<br>160<br>165<br>175|
†Rated voltage (IEC) 600V.
- ‡Rated voltage (IEC) 550V.
- Watts loss provided at rated current.
- Microswitch indicator ordered separately. See accessories on pages 212-213.
- For fuse curves see pages 158 and 159.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**151**
**High Speed Fuses**
## **Square Body Flush End Contact — 690V/700V (IEC/UL): 40-2000A**
## **690V/700V (IEC/UL) 40-2000A**
## **Specifications**
**Description:** Square body flush end contact high speed fuses. **Dimensions:** See dimensions illustrations.
## **Ratings:**
Volts: — 690Vac (IEC) — 700Vac (UL)
Amps: — 40-2000A
IR: — 200kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2, CSA Certified: Class 53787, File 1422-30.
## **Electrical Characteristics**
**==> picture [118 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.5<br>K 2) 1)<br>1.0<br>SEEEED<br>aoa<br>0.5 | AA |<br>0.4 eat<br>0.3 PT [rl] | dT CC<br>0.2 Ttyy |<br>E<br>-ECELL g<br>100 200 300 400 500 600 690<br>1) Rated voltage 600V.<br>2) Rated voltage 550V<br>**----- End of picture text -----**<br>
## **Total Clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Arc Voltage**
**==> picture [240 x 258] intentionally omitted <==**
**----- Start of picture text -----**<br>
This curve gives the peak 1.41.2 UL a<br>10 [3] eee<br>arc voltage, UL, which 9<br>may appear across the 8<br>fuse during its operation 7<br>6 Lz, [| | | |<br>as a function of theapplied<br>5<br>working voltage, Eg, (rms) pf<br>at a power factor of 15%. 4<br>Pt tT yy<br>E<br>g<br>3 et<br>| | fe<br>200 300 400 500 600 690<br>Power Losses 1.0<br>K<br>0.8 Pe p<br>Watts loss at rated current<br>0.6<br>is given in the electrical 0.5 oe<br>characteristics. The curve 0.4 aa ae<br>allows the calculation ofthe power losses at load 0.3 Sn/4n<br>currents lower than the 0.2<br>rated current. The oeA<br>given as a function of thecorrection factor, Kp, is 0.1 PEELE/ Ib<br>RMS load current, Ib, in % 30 40 50 60 70 80 90 100%<br>of the rated current.<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See pages 176 (1000V) and 189 (1250V/1300V)
## **Dimensions - mm**
|Type-B/-,|Type-B/-,|,-BKN/-,-G/-,-GKN/-|,-BKN/-,-G/-,-GKN/-|,-BKN/-,-G/-,-GKN/-|||
|---|---|---|---|---|---|---|
|**Size**|**A**|**B**<br>**D**<br>**E**|**F**|**F** (in)**|**G**|**H**|
|1*|50|51<br>59<br>45|M8|5⁄16” -18 UNC-2B|5|ø17|
|1|50|51<br>69<br>53|M8|5⁄16” -18 UNC-2B|8|ø20|
|2|50|51<br>77<br>61|M10|3⁄8” -16 UNC-2B|10|ø24|
|3|51|53<br>92<br>76|M12|1⁄2” -13 UNC-2B|10|ø30|
|**Valid for fuses type -G/- & -GKN/-.|**Valid for fuses type -G/- & -GKN/-.|**Valid for fuses type -G/- & -GKN/-.|||||
|NB: B = 65 for:|NB: B = 65 for:|Size 2, 1100-1250A|||||
|||Size 3, 1600-2000A|||||
1mm = 0.0394” / 1” = 25.4mm
**==> picture [216 x 195] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>D<br>E A<br>—<br>— re<br>F<br>E H<br>a o<br>LL<br>JR G<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**152**
**High Speed Fuses**
## **Square Body Flush End Contact — 690V/700V (IEC/UL): 40-2000A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|||||||
|---|---|---|---|---|---|---|---|---|---|
|**Catalog Numbers**||||**Size**|**Electrical Characteristics**|||||
|**-B/-**<br>**Visual**<br>**Indicator**|**-BKN/-**<br>**Type K**<br>**Indicator**<br>**for Micro**|**-G/-**<br>**Visual**<br>**Indicator**|**-GKN/-**<br>**Type K**<br>**Indicator**<br>**for Micro**|||||||
||||||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**|||**Watts**<br>**Loss**|
|||||||**Pre-arc**||**Clearing**<br>**at 660V**||
|170M3408<br>170M3409<br>170M3410<br>170M3411<br>170M3412<br>170M3413<br>170M3414<br>170M3415<br>170M3416<br>170M3417<br>170M3418<br>170M3419<br>170M3420<br>170M3421<br>170M3422<br>170M3423|170M3458<br>170M3459<br>170M3460<br>170M3461<br>170M3462<br>170M3463<br>170M3464<br>170M3465<br>170M3466<br>170M3467<br>170M3468<br>170M3469<br>170M3470<br>170M3471<br>170M3472<br>170M3473|170M3508<br>170M3509<br>170M3510<br>170M3511<br>170M3512<br>170M3513<br>170M3514<br>170M3515<br>170M3516<br>170M3517<br>170M3518<br>170M3519<br>170M3520<br>170M3521<br>170M3522<br>170M3523|170M3558<br>170M3559<br>170M3560<br>170M3561<br>170M3562<br>170M3563<br>170M3564<br>170M3565<br>170M3566<br>170M3567<br>170M3568<br>170M3569<br>170M3570<br>170M3571<br>170M3572<br>170M3573|1*|40<br>50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630|1<br>2<br>4<br>7<br>10<br>15<br>21<br>27<br>34<br>48|40<br>77<br>115<br>185|270<br>515<br>770<br>1250|9<br>11<br>14<br>18<br>21<br>26<br>30<br>35<br>40<br>50<br>55<br>60<br>65<br>70<br>75<br>80|
||||||||360<br>550<br>100<br>200<br>200<br>000<br>000<br>000<br>000<br>000<br>000<br>500|2450<br>3700<br>7500<br>15000<br>28500<br>46500<br>68500<br>105000<br>140000<br>180000<br>230000<br>325000||
|170M4408<br>170M4409<br>170M4410<br>170M4411<br>170M4412<br>170M4413<br>170M4414<br>170M4415<br>170M4416<br>170M4417<br>170M4418<br>170M4419|170M4458<br>170M4459<br>170M4460<br>170M4461<br>170M4462<br>170M4463<br>170M4464<br>170M4465<br>170M4466<br>170M4467<br>170M4468<br>170M4469|170M4508<br>170M4509<br>170M4510<br>170M4511<br>170M4512<br>170M4513<br>170M4514<br>170M4515<br>170M4516<br>170M4517<br>170M4518<br>170M4519|170M4558<br>170M4559<br>170M4560<br>170M4561<br>170M4562<br>170M4563<br>170M4564<br>170M4565<br>170M4566<br>170M4567<br>170M4568<br>170M4569|1|200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>‡900|1<br>3<br>6<br>8<br>13<br>17<br>25<br>34<br>52<br>69<br>105<br>155|650<br>100<br>200<br>500<br>500<br>000<br>000<br>000<br>000<br>500<br>000<br>000|11500<br>21000<br>42000<br>59000<br>91500<br>120000<br>170000<br>230000<br>350000<br>465000<br>725000<br>‡850000|45<br>55<br>58<br>60<br>65<br>70<br>72<br>75<br>80<br>85<br>95<br>100|
|170M5408<br>170M5409<br>170M5410<br>170M5411<br>170M5412<br>170M5413<br>170M5414<br>170M5415<br>170M5416<br>170M5417<br>170M5418|170M5458<br>170M5459<br>170M5460<br>170M5461<br>170M5462<br>170M5463<br>170M5464<br>170M5465<br>170M5466<br>170M5467<br>170M5468|170M5508<br>170M5509<br>170M5510<br>170M5511<br>170M5512<br>170M5513<br>170M5514<br>170M5515<br>170M5516<br>170M5517<br>170M5518|170M5558<br>170M5559<br>170M5560<br>170M5561<br>170M5562<br>170M5563<br>170M5564<br>170M5565<br>170M5566<br>170M5567<br>170M5568|2|400<br>450<br>500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250|11000<br>15500<br>21500<br>28000<br>41000<br>60500<br>86000<br>125000<br>180000<br>245000<br>365000||74000<br>105000<br>145000<br>190000<br>275000<br>405000<br>575000<br>840000<br>1250000<br>1600000<br>2400000|65<br>70<br>75<br>80<br>90<br>95<br>105<br>110<br>115<br>120<br>130|
|170M6408<br>170M6409<br>170M6410<br>170M6411<br>170M6412<br>170M6413<br>170M6414<br>170M6415<br>170M6416<br>170M6417<br>170M6418<br>170M6419<br>170M6420<br>170M6421|170M6458<br>170M6459<br>170M6460<br>170M6461<br>170M6462<br>170M6463<br>170M6464<br>170M6465<br>170M6466<br>170M6467<br>170M6468<br>170M6469<br>170M6470<br>170M6471|170M6508<br>170M6509<br>170M6510<br>170M6511<br>170M6512<br>170M6513<br>170M6514<br>170M6515<br>170M6516<br>170M6517<br>170M6518<br>170M6519<br>170M6520<br>170M6521|170M6558<br>170M6559<br>170M6560<br>170M6561<br>170M6562<br>170M6563<br>170M6564<br>170M6565<br>170M6566<br>170M6567<br>170M6568<br>170M6569<br>170M6570<br>170M6571|3|500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250<br>1400<br>1500<br>1600<br>†1800<br>‡2000|14000<br>19500<br>31000<br>44500<br>69500<br>100000<br>140000<br>190000<br>290000<br>370000<br>460000<br>580000<br>880000<br>1150000||95000<br>135000<br>210000<br>300000<br>465000<br>670000<br>945000<br>1300000<br>1950000<br>2450000<br>3100000<br>3900000<br>†5250000<br>‡6350000|95<br>100<br>105<br>110<br>115<br>120<br>125<br>130<br>140<br>155<br>160<br>160<br>165<br>175|
†Rated voltage (IEC) 600V.
‡Rated voltage (IEC) 550V.
- Watts loss provided at rated current.
- Microswitch indicator ordered separately. See accessories on pages 212-213. • For fuse curves see pages 158 and 159.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**153**
**High Speed Fuses**
## **Square Body US Style — 690V/700V (IEC): 40-2000A**
## **690V/700V (IEC) 40-2000A**
## **Specifications**
**Description:** Square body US style high speed fuses. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 690Vac (IEC)
— 700Vac (UL)
Amps: — 40-200A
IR: — 200kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2, CSA Certified: Class 53787, File 1422-30.
## **Electrical Characteristics**
**==> picture [118 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.5<br>K 2) 1)<br>1.0 SCOCCE<br>S=S>se<br>( | wow |] fl<br>0.5 LeT] [| ft<br>0.4 et!<br>0.3 -~ {| | || [| [ Cd|<br>0.2 1) Rated voltage 600V. Z<br>2) Rated voltage 550V |<br>100 200 300 400 500 600 690<br>**----- End of picture text -----**<br>
## **Total Clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Arc Voltage**
**==> picture [246 x 260] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 1.4<br>a<br>This curve gives the peak 1.210 [3] eee UL<br>arc voltage, UL, which 9<br>may appear across the 8<br>fuse during its operationas a function of theapplied 76 eaean<br>working voltage, Eg, (rms)at a power factor of 15%. 54 FI<br>E<br>g<br>3 P| ft | fl<br>200 300 400 500 600 690<br>Power Losses 1.0<br>Kp<br>0.8 | -_+ + +++ 4<br>Watts loss at rated current<br>0.6<br>is given in the electrical 0.5 Se<br>characteristics. The curve<br>0.4 || | | Y | | |<br>allows the calculation of<br>0.3 {| | Vi | [|<br>the power losses at loadcurrents lower than the 0.2 PELL<br>rated current. The<br>correction factor, Kp, is 0.1 ELE Ib<br>given as a function of the<br>30 40 50 60 70 80 90 100%<br>RMS load current, Ib, in % °<br>of the rated current.<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
## **Dimensions - mm**
Type -FU/-, -FKE/-, FU/115-, -FKE/115
|**Size**|**A**|**B**|**B****|**C1**|**C1****|**C2**|**C2** **|**D**|**E**|**H**|**I**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|1*|50|110|148|85|123|72|110|59|45|20|10|
|1|50|136|157|104|126|78|100|69|53|25|14|
|2|50|135|159|105|125|78|99|77|61|25|14|
|3|51|135|155|106|125|77|97|92|76|36|16|
**Valid for fuses type -FU/115 & -FKE/115.
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See pages 178 (1000V) and 191 (1250V/1300V)
1mm = 0.0394” / 1” = 25.4mm
B
**==> picture [83 x 45] intentionally omitted <==**
**----- Start of picture text -----**<br>
; 6<br>A —>|<br>**----- End of picture text -----**<br>
D C1 E C2 ~~=i~~ E I H
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**154**
**High Speed Fuses**
## **Square Body US style — 690V/700V (IEC): 40-2000A**
## **Catalog Numbers**
|**Catalog Numbersg Numbers Numbers**|**Catalog Numbersg Numbers Numbers**|**Catalog Numbersg Numbers Numbers**|**Catalog Numbersg Numbers Numbers**||||||
|---|---|---|---|---|---|---|---|---|
|**Catalog Numbers**||||**Size**|**Electrical Characteristics**||||
|**-FU/-**<br>**Without**<br>**Indicator**|**Catalog Numbers**<br>**-FKE/-**<br>**Type K**<br>**Indicator**<br>**for Micro**|**Catalog Numbers**<br>**-FU/115**<br>**Without**<br>**Indicator**|**-FKE/115**<br>**Type K**<br>**Indicator**<br>**for Micro**||||||
||||||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**||**Watts**<br>**Loss**|
|||||||**t (A**<br>**Pre-arc**|**t (ASec)**<br>**Clearing**<br>**at 660V**||
|170M3608<br>170M3609<br>170M3610<br>170M3611<br>170M3612<br>170M3613<br>170M3614<br>170M3615<br>170M3616<br>170M3617<br>170M3618<br>170M3619<br>170M3620<br>170M3621<br>170M3622<br>170M3623|170M3658<br>170M3659<br>170M3660<br>170M3661<br>170M3662<br>170M3663<br>170M3664<br>170M3665<br>170M3666<br>170M3667<br>170M3668<br>170M3669<br>170M3670<br>170M3671<br>170M3672<br>170M3673|170M3708<br>170M3709<br>170M3710<br>170M3711<br>170M3712<br>170M3713<br>170M3714<br>170M3715<br>170M3716<br>170M3717<br>170M3718<br>170M3719<br>170M3720<br>170M3721<br>170M3722<br>170M3723|170M3758<br>170M3759<br>170M3760<br>170M3761<br>170M3762<br>170M3763<br>170M3764<br>170M3765<br>170M3766<br>170M3767<br>170M3768<br>170M3769<br>170M3770<br>170M3771<br>170M3772<br>170M3773|1*|**Amps**<br>40<br>50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630|40<br>77<br>115<br>185<br>360<br>550<br>1100<br>2200<br>4200<br>7000<br>10000<br>15000<br>21000<br>27000<br>34000<br>48500|270<br>515<br>770<br>1250<br>2450<br>3700<br>7500<br>15000<br>28500<br>46500<br>68500<br>105000<br>140000<br>180000<br>230000<br>325000|9<br>11<br>14<br>18<br>21<br>26<br>30<br>35<br>40<br>50<br>55<br>60<br>65<br>70<br>75<br>80|
|170M4608<br>170M4609<br>170M4610<br>170M4611<br>170M4612<br>170M4613<br>170M4614<br>170M4615<br>170M4616<br>170M4617<br>170M4618<br>170M4619<br>ALLELE<br>~~LTTE~~|170M4658<br>170M4659<br>170M4660<br>170M4661<br>170M4662<br>170M4663<br>170M4664<br>170M4665<br>170M4666<br>170M4667<br>170M4668<br>170M4669<br>ALLELE<br>~~LTTE~~|170M4708<br>170M4709<br>170M4710<br>170M4711<br>170M4712<br>170M4713<br>170M4714<br>170M4715<br>170M4716<br>170M4717<br>170M4718<br>170M4719<br>ALLELE<br>~~LTTE~~|170M4758<br>170M4759<br>170M4760<br>170M4761<br>170M4762<br>170M4763<br>170M4764<br>170M4765<br>170M4766<br>170M4767<br>170M4768<br>170M4769<br>ALLELE<br>~~LTTE~~|1<br>ALLELE<br>~~LTTE~~|200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>‡900<br>ALLELE<br>~~LTTE~~|1650<br>3100<br>6200<br>8500<br>13500<br>17000<br>25000<br>34000<br>52000<br>69500<br>105000<br>155000<br>ALLELE<br>~~LLL~~|11500<br>21000<br>42000<br>59000<br>91500<br>120000<br>170000<br>230000<br>350000<br>465000<br>725000<br>‡850000<br>ALLELE<br>~~LLL~~|45<br>55<br>58<br>60<br>65<br>70<br>72<br>75<br>80<br>85<br>95<br>100<br>ALLELE<br>~~LLL~~|
|170M5608<br>170M5609<br>170M5610<br>170M5611<br>170M5612<br>170M5613<br>170M5614<br>170M5615<br>170M5616<br>170M5617<br>170M5618<br>~~LTTE~~|170M5658<br>170M5659<br>170M5660<br>170M5661<br>170M5662<br>170M5663<br>170M5664<br>170M5665<br>170M5666<br>170M5667<br>170M5668<br>~~LTTE~~|170M5708<br>170M5709<br>170M5710<br>170M5711<br>170M5712<br>170M5713<br>170M5714<br>170M5715<br>170M5716<br>170M5717<br>170M5718<br>~~LTTE~~|170M5758<br>170M5759<br>170M5760<br>170M5761<br>170M5762<br>170M5763<br>170M5764<br>170M5765<br>170M5766<br>170M5767<br>170M5768<br>~~LTTE~~|2<br>~~LTTE~~|‡900<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250<br>~~LTTE~~|11000<br>15500<br>21500<br>28000<br>41000<br>60500<br>86000<br>125000<br>180000<br>245000<br>365000<br>~~LLL~~|‡850000<br>74000<br>105000<br>145000<br>190000<br>275000<br>405000<br>575000<br>840000<br>1250000<br>1600000<br>2400000<br>~~LLL~~|65<br>70<br>75<br>80<br>90<br>95<br>105<br>110<br>115<br>120<br>130<br>~~LLL~~|
|170M6608<br>170M6609<br>170M6610<br>170M6611<br>170M6612<br>170M6613<br>170M6614<br>170M6615<br>170M6616<br>170M6617<br>170M6618<br>170M6619<br>170M6620<br>170M6621<br>~~LTTE~~<br>LATED|170M6658<br>170M6659<br>170M6660<br>170M6661<br>170M6662<br>170M6663<br>170M6664<br>170M6665<br>170M6666<br>170M6667<br>170M6668<br>170M6669<br>170M6670<br>170M6671<br>~~LTTE~~<br>LATED|170M6708<br>170M6709<br>170M6710<br>170M6711<br>170M6712<br>170M6713<br>170M6714<br>170M6715<br>170M6716<br>170M6717<br>170M6718<br>170M6719<br>170M6720<br>170M6721<br>~~LTTE~~<br>LATED|170M6758<br>170M6759<br>170M6760<br>170M6761<br>170M6762<br>170M6763<br>170M6764<br>170M6765<br>170M6766<br>170M6767<br>170M6768<br>170M6769<br>170M6770<br>170M6771<br>~~LTTE~~<br>LATED|3<br>~~LTTE~~<br>LATED|500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250<br>1400<br>1500<br>1600<br>†1800<br>‡2000<br>~~LTTE ~~<br>LATED|14000<br>19500<br>31000<br>44500<br>69500<br>100000<br>140000<br>190000<br>290000<br>370000<br>460000<br>580000<br>880000<br>1150000<br> ~~LLL~~<br>LATED|95000<br>135000<br>210000<br>300000<br>465000<br>670000<br>945000<br>1300000<br>1950000<br>2450000<br>3100000<br>3900000<br>†5250000<br>‡6350000<br>~~LLL~~<br>LATED|95<br>100<br>105<br>110<br>115<br>120<br>125<br>130<br>140<br>155<br>160<br>160<br>165<br>175<br>~~LLL~~<br>LATED|
- Microswitch indicator ordered separately. See accessories on pages 212-213.
- For fuse curves see pages 158 and 159.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**155**
**High Speed Fuses**
## **Square Body French Style — 690V/700V (IEC/UL): 40-1500A**
## **690V/700V (IEC/UL) 40-1500A**
## **Specifications**
**Description:** Square body French style high speed fuses.
**Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 690Vac (IEC) — 700Vac (UL) Amps: — 40-1500A IR: — 200kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2 & CSA Component Acceptance file Class 1422-30, (53787) on Sizes (1, 2, 3) only
**==> picture [118 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.5<br>K<br>1.0 =<br>(|====— =é<br>0.5 fF | | P|] [ |<br>0.4 | |+ |Py| |Tt |[ CC<br>0.3 PTC<br>0.2 Pt | |dd<br>E<br>WEEE g<br>100 200 300 400 500 600 690<br>**----- End of picture text -----**<br>
## **Electrical Characteristics**
## **Total Clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Arc Voltage**
**==> picture [246 x 260] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 1.4<br>This curve gives the peak 1.210 [3] oo UL |tT<br>arc voltage, UL, which 9 ee<br>may appear across the 8<br>7 fta |] |<br>fuse during its operation | [fit]<br>as a function of theapplied 6<br>5 A<br>working voltage, Eg, (rms)<br>at a power factor of 15%. 4 P| | | fe<br>E<br>g<br>3 |tti<br>200 300 400 500 600 690<br>Power Losses 1.00.8 TTT Kp<br>Watts loss at rated current ee<br>is given in the electrical 0.60.5 Yr | {| [ [A _][ |]<br>characteristics. The curve 0.4 aaa<br>allows the calculation of 0.3 4<br>the power losses at load<br>currents lower than the 0.2<br>rated current. The L|<br>ey<br>correction factor, Kp, isgiven as a function of the 0.1 YW Ib<br>RMS load current, Ib, in % 30 ALLEL 40 50 60 70 80 90 100%<br>of the rated current.<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **Dimensions - mm**
|Type-E/-,-EKN/-<br>**Size**<br>**A**<br>**B**<br>**C**<br>1*<br>50<br>102<br>76<br>1<br>50<br>111<br>86<br>2<br>50<br>126<br>91<br>3<br>51<br>126<br>91|**D**<br>59<br>69<br>77<br>92|**E**<br>45<br>53<br>61<br>76|**H**<br>18<br>25<br>30<br>36|**I**<br>9<br>11<br>13<br>13|**J**<br>13<br>11<br>12<br>13|
|---|---|---|---|---|---|
|1mm = 0.0394” / 1” = 25.4mm||||||
**==> picture [238 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>A<br>T E 7<br>+ Vy H<br>> I Ke<br>D<br>J<br>E B<br>Sh 6<br>E<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**156**
**High Speed Fuses**
## **Square Body French Style — 690V/700V (IEC/UL): 40-1500A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|450A<br> 550A<br> 700A<br> 900A<br><br>**Catalog Numbers**<br>**-E/**<br>**-EKN/-**<br>**Type T**<br>**Type K**<br>**Indicator**<br>**Indicator**<br>**For Micro**<br>**for Micro**<br>**Size**|||||||**Electrical Characteristics**||||||||||||||
|<br>**-E/**<br>**Type T**<br>**Indicator**<br>**For Micro**|||||||||||||||||||||
||||||||**Rated**||**I2t (A2 Sec)**||||||||||||
|||450A<br> 550A<br> 700A<br> 900A<br><br> <br>**Indicator**<br>**for Micro**<br>**Size**|||||1100A<br>A<br><br>**Current**<br>**RMS-Amps**||<br>**Pre-arc**|||<br>**Clearing**<br>**at 660V**||||||||**Watts**<br>**Loss**|
|101<br>10<br>2<br>10<br>3<br>104<br>econds<br>170M3308<br>170M3309<br>170M33~~10~~<br>170M33~~11~~<br>170M33~~12~~<br>170M3313<br>170M33~~14~~<br>170M33~~15~~<br>170M33~~16~~<br>170M33~~17~~<br>170M33~~18~~<br>170M33~~19~~<br>170M33~~20~~<br>170M33~~21~~||400A <br>500A <br>630A <br>800A <br><br>170M3358<br>170M3359<br>|||||1000<br>1250<br><br>40<br>50<br>||40<br>77<br>|||270<br>515<br>~~770~~<br>~~1250~~<br>~~2450~~<br>3700<br>~~7500~~<br>~~15000~~<br>~~28500~~<br>~~46500~~<br>~~68500~~<br>~~105000~~<br>~~140000~~<br>~~180000~~||||||||9<br>11<br>14<br>18<br>21<br>26<br>30<br>35<br>40<br>50<br>55<br>60<br>65<br>70|
||~~10~~<br>|~~1~~<br>|~~70~~<br>|~~3~~<br>|~~6~~<br>|~~0~~<br>|~~63~~<br>|||~~1~~<br>|~~5~~<br>|||||||~~0~~<br>|||
||~~1~~||~~70~~|~~3~~|~~6~~|~~1~~|~~80~~|||~~1~~|~~5~~||||||||||
||~~12~~|~~1~~|~~70~~|~~3~~|~~6~~|~~2~~|~~100~~|||~~3~~|~~0~~||||~~2~~|||~~0~~|||
||13<br>|1<br>|70M<br>|3<br>|36<br>|3<br>|125<br>|||55<br>|0<br>||||3<br>|7<br>|0<br>|0<br>|||
||~~14~~<br>|~~1~~<br>|~~70~~<br>|~~3~~<br>|~~36~~<br>|~~4~~<br><br>~~*~~|~~160~~<br>|||~~11~~<br>|~~0~~<br>||||~~7~~<br>|~~5~~<br>|~~0~~<br>|~~0~~<br>|||
||~~15~~|~~1~~|~~70~~|~~3~~|~~6~~|~~5~~<br>~~1~~|~~200~~|||~~22~~|~~0~~|||~~1~~|~~5~~|||~~0~~|||
||~~6~~||~~70~~|~~3~~|~~6~~|~~6~~|~~250~~|||~~42~~|~~0~~|||~~2~~|||||||
||~~17~~|~~1~~|~~70M~~|~~3~~|~~36~~|~~7~~|~~315~~|||~~700~~|~~0~~|||~~4~~|~~6~~|~~5~~|~~0~~|~~0~~|||
||~~18~~<br>|~~1~~<br>|~~70M~~<br>|~~3~~<br>|~~36~~<br>|~~8~~<br>|~~A~~<br>~~350~~<br>|||~~1000~~<br>|~~0~~<br>|||~~6~~<br>|~~8~~<br>|~~5~~<br>|~~0~~<br>|~~0~~<br>|||
||~~19~~|~~1~~|~~70~~|~~3~~|~~6~~|~~A~~<br>~~9~~|~~400~~|||~~150~~|~~0~~||~~1~~|~~0~~|~~5~~|||~~0~~|||
||||||||||||||||||||||
||~~0~~<br>~~21~~|~~1~~|~~70~~<br>~~70M~~|~~3~~<br>~~3~~|~~7~~<br>~~37~~|~~0~~<br>~~1~~|~~450~~<br>~~500~~|||~~210~~<br>~~2700~~|~~0~~<br>~~0~~||~~1~~<br>~~1~~|~~4~~<br>~~8~~|~~0~~|~~0~~|~~0~~|~~0~~|||
|10–1<br>100<br>Virtual Pre-Arcing Time In S<br>170M43<br>170M43<br>170M43<br>170M43<br>170M43<br>170M43<br>170M43<br>170M43<br>170M43<br>170M43<br>170M43|~~08~~|~~1~~|~~70M~~|~~4~~|~~35~~|~~8~~|~~200~~|||~~165~~|~~0~~|||~~1~~|~~1~~|~~5~~|~~0~~|~~0~~||45<br>55<br>58<br>60<br>65<br>70<br>72<br>75<br>80<br>85<br>95|
||~~09~~|~~1~~|~~70~~|~~4~~|~~5~~|~~9~~|~~250~~|||~~31~~|~~0~~|||~~2~~|~~1~~|||~~0~~|||
||||||||||||||||||||||
||~~10~~<br>~~11~~|~~1~~<br>~~1~~|~~70~~<br>~~70M~~|~~4~~<br>~~4~~|~~6~~<br>~~36~~|~~0~~<br>~~1~~|~~315~~<br>~~350~~|||~~62~~<br>~~850~~|~~0~~<br>~~0~~|||~~4~~<br>~~5~~|~~2~~<br>~~9~~|~~0~~|~~0~~|~~0~~<br>~~0~~|||
||~~12~~|~~1~~|~~70M~~|~~4~~|~~36~~|~~2~~|~~400~~|||~~1350~~|~~0~~|||~~9~~|~~1~~|~~5~~|~~0~~|~~0~~|||
||~~3~~||~~70~~|~~4~~|~~6~~|~~3~~<br>~~1~~|~~450~~|||~~170~~|~~0~~||~~1~~|~~2~~|||||||
||||||||||||||||||||||
||14<br>~~15~~|1<br>~~1~~|70<br>~~70M~~|4<br>~~4~~|36<br>~~36~~|4<br>~~5~~|500<br>~~550~~|||2500<br>~~3400~~|0<br>~~0~~||1<br>~~2~~|7<br>~~3~~|0<br>~~0~~|0<br>~~0~~|0<br>~~0~~|0<br>~~0~~|||
||~~16~~|~~1~~|~~70M~~|~~4~~|~~36~~|~~6~~|~~630~~|||~~5200~~|~~0~~||~~3~~|~~5~~|~~0~~|~~0~~|~~0~~|~~0~~|||
||||||||||||||||||||||
||~~7~~||~~70~~|~~4~~|~~6~~|~~7~~|~~700~~|||~~695~~|~~0~~||~~4~~|~~6~~|||||||
||18|1|70M|4|36|8|800|||10500|0||7|2|5|0|0|0|||
|1x10<br>1x10–4<br>10<br>–3<br>10<br>–2<br>170M53~~08~~<br>170M53~~09~~<br>170M53~~10~~<br>170M5311<br>170M53~~12~~<br>170M53~~13~~<br>170M5314<br>170M5315<br>170M5316|~~08~~|~~1~~|~~70~~|~~5~~|~~35~~|~~8~~|~~400~~|||~~110~~|~~0~~|||~~7~~|~~4~~||~~0~~|~~0~~||0<br>5<br>65<br>70<br>75<br>80<br>90<br>95<br>105<br>110<br>115|
||~~09~~|~~1~~|~~70M~~|~~5~~|~~35~~|~~9~~|~~450~~|||~~1550~~|~~0~~||~~1~~|~~0~~|~~5~~|~~0~~|~~0~~|~~0~~|||
||||||||||||||||||||||
||~~10~~|~~1~~|~~70~~|~~5~~|~~36~~|~~0~~|~~500~~|||~~215~~|~~0~~||~~1~~|~~4~~|~~5~~|||~~0~~|||
||11<br>~~12~~|1<br>~~1~~|70M<br>~~70~~|5<br>~~5~~|36<br>~~6~~|1<br>~~2~~<br>~~2~~|550<br>~~630~~|||2800<br>~~410~~|0<br>~~0~~||1<br>~~2~~|9<br>~~7~~|0<br>|0<br>|0<br>|0<br>~~0~~|||
||~~13~~|~~1~~|~~70~~|~~5~~|~~36~~|~~3~~|~~700~~|||~~605~~|~~0~~||~~4~~|~~0~~|~~5~~||~~0~~|~~0~~|||
||||||||||||||||||||||
||14|1|70|5|36|4|800|||8600|0||5|7|5|0|0|0|||
||15|1|70M|5|36|5|900|||12500|0||8|4|0|0|0|0|||
|||2<br>10<br>3<br>170M5366|||||1000||10<br>4<br>180000||||||||||||
|170M6308<br>170M6309<br>170M6310<br>170M6311<br>170M6312<br>170M6313<br>170M6314<br>170M6315<br>170M6316<br>170M6317<br>170M6318||Prospecti<br>170M6358<br>170M6359<br>170M6360|||||ve Current In Amper<br>500<br>550<br>630||es RMS<br>14000<br>19500<br>31000|||95000<br>135000<br>210000||||||||95<br>100<br>105|
|||170M6361<br>170M6362<br>170M6363<br>3|||||700<br>800<br>900||44500<br>69500<br>100000|||300000<br>465000<br>670000||||||||110<br>115<br>120|
|||170M6364<br>170M6365|||||1000<br>1100||140000<br>190000|||945000<br>1300000||||||||125<br>130|
|||170M6366<br>170M6367<br>170M6368|||||1250<br>1400<br>1500||290000<br>370000<br>460000|||1950000<br>2450000<br>3100000||||||||140<br>155<br>160|
- Watts loss provided at rated current.
- Microswitch indicator ordered separately. See accessories on pages 212-213.
- For fuse curves see pages 158 and 159.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**157**
**High Speed Fuses**
## **Square Body, French Style - Size 1*, 1 — 690V/700V (IEC/UL): 40-2000A Size 1* — 40-630A: 690V Size 1 — 200-900A: 690V Time-Current Curve Time-Current Curve**
## **Peak Let-Through Curve**
**==> picture [247 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
105<br>B<br>poolTTee7 550A450A350A [630A][500A][400A] 315A<br>ee —_ 250A 200A<br>104 4]: @M@XZ—2sees — 160A100A [125A]<br>80A<br>eee 63A40A 50A<br>Pt ee eee<br>en eee eet<br>epee eee eal<br>103 eee |<br>a<br>ey A eae es eee a ee ee<br>| AC5 e ne<br>2x102 1x10 AT 2 OUT 103 TEP 104 105 106<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**==> picture [251 x 556] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4] | | | | |<br>ee ee<br>a a AY<br>103<br>a LAA<br>Po ey<br>eeee<br>10 [2]<br>_———— rerrr<br>A A<br>Sees emesis pune tne Sa eee<br>E+ ee ihe et HE EH<br>10 [1] Po TEVA AATP<br>| | AIIMET<br>——S==S=S == =. =.= += =. = ==.=e<br>SeAt| A<br>pf tT TAY AVANT<br>100 BRE ALANA<br>PEE<br>SSS SSS eS ree<br>aa aa a|OW 0<br>10 [–1]<br>}—_|ee ft TPA A A<br>10–2 El Ee<br>SSS ener eee as Ss EE<br>[TAA<br>10–3 PRNRRA HF<br>FHRRR EE<br>1x10 [–4] NUNN<br>1x10 NE [2] ENN 10 [3] 10 [4] ANGI 10 [5]<br>Prospective Current In Amps<br>Peak Let-Through Curve<br>105<br>B<br>900A<br>Ieee 700A [800A]<br>J AA eeeiyee —_ 550A450A [630A][500A]<br>350A [400A] 315A<br>a en) Gee Se: —_ 250A<br>200A<br>104<br> EBasaa&ay‘_-reP44 W’a<br>a ey a<br>Pt EE Ae eee<br>eer TTT<br>10 [3] ey mE<br>A |<br>EA A<br>|ooALA Ty<br>2x102 1x10 Za 2 103 104 105 106<br>900 amp fuse is derated to 550V (IEC).<br>315A 50A630A00A800A<br>200A 250A 350A400A450A500A5 7 900A<br>Virtual Pre-Arcing Time In Seconds<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
## **Data Sheet: 17056316**
**Data Sheet: 17056314**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**158**
**High Speed Fuses**
## **Square Body, French Style - Size 2, 3 — 690V/700V (IEC/UL): 40-2000A**
**Size 2 — 400-1250A: 690V Time-Current Curve**
**==> picture [261 x 551] intentionally omitted <==**
**----- Start of picture text -----**<br>
104<br>103<br>10 [2]<br>A A<br>101<br>10 [0]<br>10 [–1]<br>10–2<br>10 [–3]<br>1x10 [–4] 1x102 103 104 105<br>Prospective Current In Amps RMS<br>Peak Let-Through Curve<br>106<br>B<br>1250A<br>105 1000A800A [1100A] 900A700A<br>630A500A400A 550A450A<br>104<br>A<br>2x103 1x103 104 105 106 107<br>Prospective Short-Circuit Current Symmetrical RMS<br>450A 550A 700A 900A<br>400A 500A 630A 800A 1000A1100A1250A<br>Virtual Pre-Arcing Time In Seconds<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Size 3 — 500-2000A: 690V Time-Current Curve**
**==> picture [253 x 568] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>103<br>102<br>A A<br>10 [1]<br>10 [0]<br>10 [–1]<br>10 [–2]<br>10 [–3]<br>1x10 [–4]<br>1x10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Current In Amps RMS<br>Peak Let-Through Curve<br>106<br>B<br>105 1800A1500A1250A1000A800A [2000A][1600A][1400A][1100A] 900A700A<br>630A<br>500A 550A<br>104<br>A<br>2x103 1x103 104 105 106 107<br>Prospective Short-Circuit Current Symmetrical RMS<br>1800A fuse is derated to 600V (IEC).<br>2000A fuse is derated to 550V (IEC).<br>630A 800A 1000A<br>500A 50A5 00A7 00A9 1100A 1250A400A 1500A1 600A 1800A1 2000A<br>Virtual Pre-Arcing Time In Seconds<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
## **Data Sheet: 17056320**
**Data Sheet: 17056318**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**159**
**High Speed Fuses**
## **Square Body DIN 43 620 — 690V/700V (IEC/UL): 40-1000A**
## **690V/700V (IEC/UL) 40-1000A**
## **Specifications**
**Description:** Square body DIN 43 620 blade style high speed fuses.
**Dimensions:** See dimensions illustration.
## **Ratings:**
Volts:— 690Vac (IEC) — 700Vac (UL) Amps:— 40-1000A IR:— 200kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
## **Electrical**
## **Characteristics**
## **Total Clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Arc Voltage**
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of theapplied working voltage, Eg, (rms) at a power factor of 15%.
## **Power Losses**
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Full Range Fuses in This Body Style**
- See page 168
## **Dimensions (mm)**
Type DIN 1*, DIN 2, DIN 3 Size ~~a~~ A B D E F H 1* 69 135 58 45 40 20 2 69 150 71 55 48 26 ~~Oe~~ 3 68 150 88 76 60 33 1mm = 0.0394” / 1” = 25.4mm Oo
**==> picture [240 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
«——— A ——>|<br>a Indicator<br>-J =<br>H<br>7<br>D<br>F B<br>— =<br>Po)<br>E 6<br>fa ) | | 7<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**160**
**High Speed Fuses**
## **Square Body DIN 43 620 — 690V/700V (IEC/UL): 40-600A**
## **Catalog Numbers**
|**Catalog Numbers**|**Size**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|
|**Catalog Numbers**<br>**DIN Type T**<br>**Indicator**<br>**for Micro**||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2Sec)**||**Watts**<br>**Loss**|
||||**Pre-arc**|**Clearing**<br>**at 660V**||
|170M3808D<br>170M3809D<br>170M3810D<br>170M3811D<br>170M3812D<br>170M3813D<br>170M3814D<br>170M3815D<br>170M3816D<br>170M3817D<br>170M3818D<br>170M3819D<br>170M4863D<br>170M4864D<br>170M4865D<br>170M4866D<br>170M4867D|1*|**Amps**<br>40<br>50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630<br>700|40<br>78<br>120<br>185<br>360<br>550<br>1150<br>2300<br>4350<br>7300<br>10000<br>16000<br>21500<br>27000<br>33500<br>48500<br>69500|285<br>550<br>850<br>1350<br>2600<br>3900<br>8250<br>16500<br>31000<br>52000<br>73000<br>115000<br>155000<br>190000<br>240000<br>345000<br>495000|4<br>4.5<br>6.5<br>8.5<br>10<br>11<br>12<br>12.5<br>16<br>20<br>21.5<br>60<br>26.3<br>28.5<br>33<br>37.5<br>39|
|170M5808D<br>170M5809D<br>170M5810D<br>170M5811D<br>170M5812D<br>170M5813D<br>170M5814D<br>170M5820D<br>170M5816D<br>170M5817D|2|400<br>450<br>500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100|11000<br>16000<br>21500<br>29000<br>41000<br>60500<br>86000<br>125000<br>180000<br>245000|79000<br>115000<br>155000<br>215000<br>295000<br>430000<br>610000<br>895000<br>1300000<br>1750000|29<br>32<br>34<br>36<br>42<br>43<br>48<br>52<br>53<br>56|
|170M6808D<br>170M6809D<br>170M6810D<br>170M6811D<br>170M6812D<br>170M6813D<br>170M6814D<br>170M6892D<br>170M8554D<br>170M8555D<br>170M8556D<br>170M8557D|3|500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250<br>1400<br>1500<br>1600|14000<br>19500<br>31000<br>45000<br>69500<br>100000<br>140000<br>190000<br>300000<br>380000<br>470000<br>585000|99500<br>140000<br>220000<br>320000<br>490000<br>720000<br>985000<br>1400000<br>2150000<br>2700000<br>3350000<br>4150000|43<br>44<br>45<br>46<br>48<br>50<br>56<br>57<br>61<br>70<br>72<br>74|
• Watts loss provided at rated current. • Microswitch indicator ordered separately. See accessories on pages 212-213.
## **Size 1* — 40-630A: 690V**
## **Time-Current Curve**
## **Peak Let-Through Curve**
• For fuse curves see page 162.
## **Rated Current**
The rated current of this fuse range has been given with copper conductors that have a current density of 1.3A/mm[2] (IEC 60269-4). For conductor cross section according to IEC 60269-1, the fuses must be derated. Please contact Bussmann for application assistance.
**Data Sheet: 17056314**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**161**
**High Speed Fuses**
## **Square Body DIN 43 620 — 690V/700V (IEC/UL): 40-1000A**
**Size 2 — 400-1250A: 690V Time-Current Curve**
**Size 3 — 500-2000A: 690V Time-Current Curve**
**Peak Let-Through Curve**
**Peak Let-Through Curve**
**Data Sheet: 17056320**
**Data Sheet: 17056318**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**162**
**High Speed Fuses**
## **Square Body Flush End Contact — 690/700V (IEC/UL): 1000-4000A**
## **690V (IEC) 1000-4000A**
## **Specifications**
**Description:** Square body flush end contact high speed fuses. **Dimensions:** See dimensions illustrations.
## **Ratings:**
Volts: — 690Vac Amps: — 1000-4000A
IR: — 200kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
## **Electrical Characteristics**
## **Total Clearing I[2] t**
**==> picture [118 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.5<br>K 1)<br>1.0<br>0.5 =a<br>0.4 CeLLer<br>0.3 im {| | [ |<br>0.2 Pt tT |<br>E<br>g<br>Ft | ft tf<br>100 200 300 400 500 600 690<br>1) Rated voltage 500V<br>**----- End of picture text -----**<br>
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Arc Voltage**
**==> picture [244 x 266] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.4<br>This curve gives the peak 1.2 UL<br>10 [3] =| |PET<br>arc voltage, UL, which 9<br>a<br>may appear across the 8<br>fuse during its operationas a function of the 76 er7rd<br>applied working voltage, 5<br>Eg, (rms) at a power 4 P| | |<br>factor of 15%.<br>E<br>g<br>3 tt<br>ft fe<br>200 300 400 500 600 690<br>Power Losses<br>1.0<br>K<br>Watts loss at rated 0.8 === p<br>current is given in the 0.6 a a<br>electrical characteristics. 0.5<br>The curve allows the 0.4 P| | | yy]<br>calculation of the power 0.3<br>losses at load currents<br>lower than the rated 0.2 FEE<br>current. The correction<br>EE<br>factor, Kp, is given as afunction of the RMS load 0.1 Dannaal Ib<br>30 40 50 60 70 80 90 100%<br>current, Ib, in % of the<br>rated current.<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
## **Dimensions - mm**
- - - - Type 4B/ , 4BKN/ , 4G/ , 4GKN/
**==> picture [247 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
Size F (in) G<br>4B M10 10 deep 33<br>4G 1⁄2” -13 UNC-2B 10 deep 38<br>1mm = 0.0394” / 1” = 25.4mm<br>105<br>F Ø4<br>ay).<br>G 105<br>leeeeeee ened | 15<br>— Ø56<br>53 67<br>**----- End of picture text -----**<br>
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See pages 182 (1000V) and 195 (1250V)
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**163**
**High Speed Fuses**
## **Square Body Flush End Contact — 690V (IEC): 1000-4000A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**||||||||
|---|---|---|---|---|---|---|---|---|---|
|**Catalog Numbers**|||**Size**|**Electrical Characteristics**||||||
|**-BKN/-**<br>**-B/-**<br>**Type K**<br>**Visual**<br>**Indicator**<br>**Indicator**<br>**for Micro**|**-G/-**<br>**Visual**<br>**Indicator**|**-GKN/-**<br>**Type K**<br>**Indicator**<br>**for Micro**||||||||
|||||**Rated Current RMS**||**I2t (A2** **Sec)**||**Watts Loss**||
|||||**Norm.**<br>**Cool.**|**Liquid**<br>**Cool.**|**Pre-arc**|**Clearing**<br>**at 660V**|**Norm.**<br>**Cool.**|**Liquid**<br>**Cool.**|
|170M7058<br>170M7078<br>170M7059<br>170M7079<br>170M7060<br>170M7080<br>170M7061<br>170M7081<br>170M7062<br>170M7082<br>170M7063<br>170M7083<br>170M7064<br>170M7084<br>170M7065<br>170M7085<br>170M7066<br>170M7086|170M7098<br>170M7099<br>170M7100<br>170M7101<br>170M7102<br>170M7103<br>170M7104<br>170M7105<br>170M7106|170M7118<br>170M7119<br>170M7120<br>170M7121<br>170M7122<br>170M7123<br>170M7124<br>170M7125<br>170M7126|4|1000<br>1250<br>1400<br>1600<br>2000<br>2500<br>3000<br>3500<br>†4000|1350<br>1700<br>1900<br>2200<br>2700<br>3400<br>4100<br>4700<br>†5400|76000<br>145000<br>205000<br>305000<br>600000<br>1200000<br>2000000<br>3250000<br>4700000|505000<br>965000<br>1400000<br>2050000<br>3950000<br>7800000<br>13500000<br>22000000<br>†28000000|175<br>195<br>205<br>220<br>245<br>275<br>305<br>325<br>355|315<br>355<br>375<br>405<br>445<br>495<br>555<br>585<br>640|
†Rated voltage (IEC) 500V.
- Watts loss provided at rated current.
• Liquid Cool. = Liquid cooling. Temperature on the terminals not to exceed 60°C. • Microswitch indicator ordered separately. See accessories on pages 212-213.
## **Size 4 — 1000-4000A: 690V Time-Current Curve**
**==> picture [541 x 367] intentionally omitted <==**
**----- Start of picture text -----**<br>
Peak Let-Through Curve<br>10 [4] 10 [6]<br>B<br>10 [3] 4000A<br>3500A<br>2500A [3000A]<br>2000A [2200A]<br>10 [5] 1600A<br>1400A<br>1250A<br>102 1000A<br>A<br>A<br>10 [1] 104<br>A<br>100 2x103<br>1x103 104 105 106 107<br>Prospective Short-Circuit Current Symmetrical RMS<br>10 [–1] 4000A fuse is derated to 500V (IEC).<br>10–2<br>10 [–3]<br>1x10–4<br>1x10 [3] 10 [4] 10 [5] 10 [6]<br>Prospective Current in Amps RMS<br>2000A 3500A<br>1000A 1250A 1400A1600A 2200A 2500A 3000A 4000A<br>Peak Let-Through Current<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
**Data Sheet: 17056328**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**164**
**High Speed Fuses**
## **Square Body Flush End Contact Size 23, 24 — 660V (IEC): 1000-7500A**
## **660V (IEC) 1000-7500A**
## **Arc Voltage**
## **Specifications**
**Description:** High speed square body fuses, for the protection of the power rectifier section of the equipment.
**Dimensions:** See dimensions illustrations.
**Ratings:**
Volts: — 660Vac Amps: — 1000-4000A IR: — 300kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
## **Electrical Characteristics**
**==> picture [193 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
Total clearing I [2] t<br>a \<br>te SSS: ‘a<br>ee<br>SSMAEeei oO<br>o2 PET EET EEE<br>100 «2000Pt300 ttte!400 oss 02“CET1000 OOO<br>Size 23 Size 24<br>**----- End of picture text -----**<br>
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
**==> picture [152 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Size 23 Size 24<br>**----- End of picture text -----**<br>
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg , (rms) at a power factor of 15%.
## **Power Losses**
**==> picture [185 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
30405060 Size 23 70 80 op qoom kg —G5—ha—na Size 24 9<br>**----- End of picture text -----**<br>
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
## **Features and Benefits**
- Low watts loss
- Superior cycling capability
## **For Other Voltage Ratings in This Body Style**
- See pages 185 (1000V) and 198 (1250V)
## **Typical Applications**
- Power converters/rectifiers
- Reduced voltage starters
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**165**
**High Speed Fuses**
## **Square Body Flush End Contact Size 23, 24 — 660V**
## **(IEC): 1000-7500A**
|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|**-BU/55**<br>**Visual**<br>**Indicator**<br>**Catalogue Number**<br>**Electrical Characteristics**<br>**I**<br>**2t (A**<br>**2Sec)**<br>**-BKE/55**<br>**Type K**<br>**Indicator**<br>**-BKN/55**<br>**Type K**<br>**Indicator**<br>**-GU/55**<br>**Visual**<br>**Indicator**<br>**-GKE/55**<br>**Type K**<br>**Indicator**<br>**-GKN/55**<br>**Type K**<br>**Indicator**<br>**Watt**<br>**Loss**<br>**(W)**<br>**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**<br>**Fuse**<br>**Size**<br>**Pre-arc**<br>**Clearing**<br>**at 660V**<br>170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938<br>1000<br>79,000<br>530,000<br>170.0<br>170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939<br>1100<br>95,000<br>635,000<br>185.0<br>170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940<br>1250<br>155,000<br>1,050,000<br>190.0<br>170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941<br>1400<br>200,000<br>1,350,000<br>210.0<br>170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942<br>1500<br>240,000<br>1,650,000<br>215.0<br>23<br>170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943<br>660<br>1600<br>315,000<br>2,150,000<br>220.0<br>170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944<br>1800<br>450,000<br>3,050,000<br>230.0<br>170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945<br>2000<br>625,000<br>4,200,000<br>240.0<br>170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946<br>2200<br>805,000<br>5,400,000<br>255.0<br>170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947<br>2500<br>1,250,000<br>8,350,000<br>265.0<br>170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948<br>3000<br>2,250,000<br>15,500,000<br>285.0<br>170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949<br>600<br>3500<br>3,450,000<br>21,000,000<br>315.0<br>170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950<br>550<br>4000<br>5,000,000<br>27,500,000<br>340.0<br>Re<br>~~[|~~<br>~~esa~~<br>~~EEL~~<br>~~po~~|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||Data Sheet: 170K6326|||||||||||||
|**Catalog Numbers:**||||||||||||||
||||**Catalogue Number**|||**Electrical Characteristics**||||||||
||**Fuse**<br>**Size**|**-BU/60**<br>**without**<br>**Indicator**|**-BKN/60**<br>**Type K**<br>**Indicator**|**-GU/60**<br>**without**<br>**Indicator**|**-GKN/60**<br>**Type K**<br>**Indicator**|**Rated**<br>**Voltage**<br>**(V)**<br>**Rated**<br>**Current**<br>**RMS-Amp**|**I**<br>**2t (A**<br>**2Sec)**<br>**Pre-arc**<br>**Clearing at**<br>**660V**|||**Watts**<br>**Loss**<br>**(W)**||||
|||170M7138|170M7158|170M7198|170M7218|2000|340000||2300000|340||||
|||170M7139|170M7159|170M7199|170M7219|2500|650000||4350000|390||||
|||170M7140|170M7160|170M7200|170M7220|3000|1100000||7300000|430||||
|||170M7141|170M7161|170M7201|170M7221|3500|1800000||12000000|460||||
|||170M7142|170M7162|170M7202|170M7222|4000|2700000||18000000|490||||
||24|170M7143|170M7163|170M7203|170M7223|690<br>4500|3800000||25500000|520||||
|||170M7144|170M7164|170M7204|170M7224|5000|5450000||36500000|540||||
|||170M7145|170M7165|170M7205|170M7225|5500|7400000||49500000|560||||
|||170M7146|170M7166|170M7206|170M7226|6000|9600000||64000000|580||||
|||170M7147|170M7167|170M7207|170M7227|6500|12500000||83000000|600||||
|||170M7148|170M7168|170M7208|170M7228|7000|15000000||100000000|630||||
|||170M7149|170M7169|170M7209|170M7229|500<br>7500|18500000||†93000000|660||||
† A[2] s @ 500V Data Sheet: 170K6332
## **Dimensions - mm**
## **Size 23**
Type – BU/ 55, - BKE/ 55, - BKN/ 55, - GU/ 55, - GKE/ 55, - GKN/ 55
## **Size 24**
Type – BU/ 55, - BKE/ 55, - BKN/ 55, - GU/ 55, - GKE/ 55, - GKN/ 55
**Size A** 23G 2x2 M10 23B 3/8” 16UNC-2B
**Size A** 24BKN 2x3 M12 24GKN 2x3[1] /2” 16UNC-2B
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**166**
**High Speed Fuses**
## **Square Body Flush End Contact Size 23, 24 — 660V (IEC): 1000-7500A**
## **Size 23 — 10000-4000A: 660V**
**Time-Current Curve**
## **Size 24 — 2000-7500A: 660V**
**Time-Current Curve**
**==> picture [124 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**==> picture [125 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**Peak Let-Through Curve**
## **Peak Let-Through Curve**
**Data Sheet: Available upon request**
**Data Sheet: Available upon request**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**167**
**High Speed Fuses**
## **Square Body DIN 43 620 — 690V (IEC): 10-800A Class gR — Full Range Fuses**
## **690V (IEC) 10-800A**
## **Specifications**
**Description:** Square body DIN 43 620 blade style high speed fuses. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 690Vac (IEC) Amps: — 10-800A
IR: — 300kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
## **Electrical**
## **Characteristics**
**Total clearing I[[2]] t** 1,5 K The total clearing I[2] t at 1,0 rated voltage and at power ~~|~~ factor of 15% are given in the electrical 0,5 ~~in~~ characteristics. For other 0,4 ~~Pf ft~~ voltages, the clearing I[2] t is 0,3 ~~TT~~ found by multiplying by ~~PPT~~ correction factor, K, given 0,2 ~~i~~ Eg as a function of applied 200 300 400 500 600 700 working voltage, Eg, (rms).
## **Total clearing I[[2]] t**
## **Arc Voltage**
**==> picture [243 x 253] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>UL<br>2,5 ee ee ee ee<br>This curve gives the 2<br>peak arc voltage, UL, 1,81,6<br>which may appear 1,41,2 pf==|_| |_|<br>across the fuse during 10 [3]<br>its operation as a 8 ee<br>function of the applied 76<br>, 5<br>working voltage Eg a d<br>(rms) at a power factor 4<br>of 15%. 3 a Eg<br>200 300 400 500 600 700<br>Power Losses<br>Watts loss at rated current 1,0 K<br>0,8 p<br>is given in the electrical 0,7 FEES<br>characteristics. The curve 0,6<br>EEE<br>allows the calculation ofthe power losses at load 0,50,4 | tf | | vy ft<br>currents lower than the 0,3<br>rated current. The<br>correction factor, Kp, is 0,150,2 7<br>given as a function of the FEE<br>RMS load current, Ib, in %of the rated current. 0,130 40 50 60 70 80 90 100% D4GEREE Ib<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Operating Class aR Fuses in This Body Style**
- See page 160
## **Dimensions - mm**
Type DIN 00, DIN 1, DIN 2, DIN 3 **Size A B Max D Max E F Min H** 00 49 78.5 60 30 35 15 1 68 135 66 52 40 20 2 68 150 74 60 48 25 3 68 150 89 75 60 32 1 mm = 0.0394” 1” = 25.4 mm
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**168**
**High Speed Fuses**
## **Square Body DIN 43 620 — 690V (IEC): 10-800A Class gR — Full Range Fuses**
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Size**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|
|**Type T**<br>**Indicator**<br>**For Micro**||**RMS**<br>**Amp**<br>**Rating***|**I2t (A2 **|**Sec)**|**Watts**<br>**Loss**|
||||**Pre-arc**|**Clearing**<br>**at 600V**||
|170M2691<br>170M2692<br>170M2693<br>170M2694<br>170M2695<br>170M2696<br>170M2697<br>170M2698<br>170M2699<br>170M2700<br>170M2701<br>170M2702|00|**Rating**<br>10<br>16<br>20<br>25<br>32<br>40<br>50<br>63<br>80<br>100<br>125<br>160|3.8<br>7.2<br>13<br>24<br>53<br>95<br>185<br>345<br>695<br>1250<br>2300<br>4350|20<br>38<br>70<br>125<br>275<br>490<br>1000<br>1800<br>3600<br>6650<br>12000<br>22500|3.5<br>5.5<br>6<br>8<br>9<br>10<br>11<br>14<br>16<br>19<br>23<br>29|
|170M4176<br>170M4177<br>170M4178<br>170M4179<br>170M4180<br>170M4181<br>170M4182<br>170M4183<br>170M4184<br>170M4185<br>170M4186|1|50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400|135<br>245<br>500<br>950<br>1850<br>3450<br>6750<br>13500<br>26000<br>34000<br>48500|705<br>1300<br>2600<br>4850<br>9500<br>18000<br>34500<br>70500<br>135000<br>175000<br>250000|12<br>15<br>17<br>20<br>23<br>28<br>31<br>35<br>41<br>45<br>48|
|170M5881<br>170M5882<br>170M5883<br>170M5884<br>170M5885<br>170M5886<br>170M5887<br>170M5888<br>170M5889|2|200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630|5650<br>10000<br>19500<br>26000<br>39500<br>55500<br>73000<br>100000<br>150000|29000<br>52500<br>105000<br>135000<br>205000<br>290000<br>375000<br>515000<br>770000|33<br>40<br>46<br>50<br>53<br>59<br>66<br>70<br>79|
|170M6080<br>170M6081<br>170M6082<br>170M6083<br>170M6084<br>170M6085<br>170M6086<br>170M6087|3|350<br>400<br>450<br>500<br>550<br>630<br>700<br>800|23000<br>34000<br>48500<br>64000<br>84500<br>125000<br>160000<br>245000|120000<br>175000<br>250000<br>330000<br>435000<br>645000<br>840000<br>1300000|55<br>59<br>62<br>67<br>70<br>85<br>93<br>99|
*The RMS amp rating of this fuse range is given with open fuse bases connected to copper conductors according to IEC 60269, Part 1, table 10. When used in enclosed fuse bases/ disconnects, derating factors have to be observed. Please contact Bussmann for application assistance.
- Watts loss provided at rated current.
- Microswitch ordered separately. See accessories on page 212-213. • For fuse curves see pages 170 and 171.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**169**
**High Speed Fuses**
## **Square Body, DIN 43 620 - Size 00, 1 — 690V (IEC): 10-800A Class gR — Full Range Fuses**
## **Size 00 — 10-160A: 690V Time-Current Curve**
## **Size 1 — 50-400A: 690V Time-Current Curve**
**==> picture [231 x 516] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>10 [3]<br>10 [2]<br>10<br>1s<br>10 [-1]<br>10 [-2]<br>10 [-3]<br>10 [-4]<br>10 10 [2] 10 [3] 10 [4]<br>Prospective Current In Amp RMS<br>Peak Let-Through Curve<br>10 [5]<br>10 [4]<br>10 [3]<br>2x10 [2]<br>10 10 [2] 10 [3] 10 [4] Amp 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>160A<br>125A100A<br>80A 63A<br>50A40A<br>32A25A<br>20A16A<br>10A<br>63A 100A 160A<br>80A 125A<br>16A 25A 40A<br>10A 20A 32A 50A<br>Virtual Pre-arcing Time In Seconds<br>Peak Let-Through Current In Amperes<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [232 x 512] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>10 [3]<br>10 [2]<br>10<br>1s<br>10 [-1]<br>10 [-2]<br>10 [-3]<br>10 [-4]<br>5x10 [1] 10 [2] 10 [3] 10 [4] 5x10 [4]<br>Prospective Current In Amp RMS<br>Peak Let-Through Curve<br>10 [5]<br>10 [4]<br>10 [3]<br>2x10 [2]<br>10 10 [2] 10 [3] 10 [4] Amp 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>400A350A<br>315A250A<br>200A160A<br>125A100A<br>80A 63A<br>50A<br>250A 350A<br>400A<br>63A 100A 160A<br>50A 80A 125A 200A<br>Virtual Pre-arcing Time In Seconds<br>Peak Let-Through Current In Amperes<br>315A<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**170**
**High Speed Fuses**
## **Square Body, DIN 43 620 - Size 2, 3 — 690V (IEC): 10-800A Class gR — Full Range Fuses**
## **Size 2 — 200-630A: 690V Time-Current Curve**
## **Size 3 — 350-800A: 690V Time-Current Curve**
**==> picture [496 x 515] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4] 10 [4]<br>10 [3] 10 [3]<br>10 [2] 10 [2]<br>10 10<br>1s 1s<br>10 [-1] 10 [-1]<br>10 [-2] 10 [-2]<br>10 [-3] 10 [-3]<br>10 [-4] 10 [-4]<br>10 [2] 10 [3] 10 [4] 10 [5] 10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Current In Amp RMS Prospective Current In Amp RMS<br>Peak Let-Through Curve Peak Let-Through Curve<br>10 [5] 10 [5]<br>10 [4] 10 [4]<br>10 [3] 10 [3]<br>2x10 [2] 2x10 [2]<br>10 [2] 10 [3] 10 [4] 10 [5] Amp 10 [6] 10 [2] 10 [3] 10 [4] 10 [5] Amp 10 [6]<br>Prospective Short-Circuit Current Symmetrical RMS Prospective Short-Circuit Current Symmetrical RMS<br>800A<br>550A700A450A 400A630A00A<br>350A<br>630A<br>550A 500A<br>450A 100A<br>350A 315A<br>250A 200A<br>500A 630A<br>400A 500A 630A 800A<br>350A 450A 550A 700A<br>200A 315A 400A<br>250A 350A 450A 550A<br>Virtual Pre-arcing Time In Seconds Virtual Pre-arcing Time In Seconds<br>Peak Let-Through Current In Amperes Peak Let-Through Current In Amperes<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**171**
**High Speed Fuses**
## **Square Body DIN 43 653 — 1000V (IEC): 20-315A**
## **1000V (IEC) 20-315A**
**==> picture [109 x 111] intentionally omitted <==**
## **Specifications**
Description: Square body DIN 43 653 stud-mount high speed fuses.
**Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 1000Vac (20-250A) — 900Vac (315A)
Amps: — 20-315A IR: — 150kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
## **Electrical Characteristics**
## **Total clearing I[2] t**
|**oa cearng**<br>The total clearing I2t at rated<br>voltage and at power factor<br>of 15% are given in the<br>electrical characteristics. For<br>other voltages, the clearing<br>I2t is found by multi-plying by<br>correction factor, K, given as<br>a function of applied working<br>voltage, Eg, (rms).<br>1,5<br>1,0<br>0,5<br>0,4<br>0,3<br>0,2<br>2<br> <br>**Dimensions - mm**<br>Type 00TN/80–00/80|K|||~~*~~||
|---|---|---|---|---|---|
|||||||
|||||||
|||||||
|||||||
|||||||
|||||||
|||||||
|||||||
||||||Eg|
|||||||
|<br>**ize**<br>**Max A**<br>**B**<br>**C**<br>**D**<br>**Max E**<br>**F**<br>**G**<br>**H**||||||
|0/80<br>54<br>98<br>78<br>51<br>30<br>28<br>10||||||
|0TN/80<br>54<br>98<br>78<br>51<br>30<br>28<br>67<br>10||||||
|mm = 0.0394” / 1” = 25.4mm||||||
**==> picture [250 x 257] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 2,53 U L<br>This curve gives the peak 2<br>arc voltage, UL, which may 1,81,6<br>appear across the fuse 1,41,2<br>during its operation as a 10 [3]<br>function of the applied 87<br>working voltage Eg, (rms)at a power factor of 15%. 65<br>4<br>3 Eg<br>200 400 600 800 1000<br>Power Losses<br>1,0<br>Watts loss at rated current 0,8 Kp<br>is given in the electrical 0,7<br>characteristics. The curve 0,6<br>0,5<br>allows the calculation of<br>0,4<br>the power losses at load<br>currents lower than the 0,3<br>rated current. The<br>0,2<br>correction factor, Kp, is 0,15<br>given as a function of the<br>RMS load current, Ib, in % 0,1 Ib<br>of the rated current. 30 40 50 60 70 80 90 100%<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See page 145 (690V/700V)
**==> picture [59 x 49] intentionally omitted <==**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**172**
**High Speed Fuses**
## **Square Body DIN 43 653 — 1000V (IEC): 20-315A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**||**Electrical**|**Electrical**|**Characteristics**|**Characteristics**|**Characteristics**|
|---|---|---|---|---|---|---|---|
|<br>**00/80**<br>**Visual**<br>**Indicator for **<br>**Micro**|<br>**00TN/80**<br>**Type T**<br> **Indicator for**<br>**Micro**|**Size**|**Rated**<br>**Voltage **|**Rated**<br>**Current**<br> **RMS Amps**|**I2t (A2 Sec)**||**Watts**<br>**Loss**|
||||||**Pre-arc**|**Clearing**<br>**at Rated**<br>**Voltage**||
|170M4802<br>170M4803<br>170M4804<br>170M4805<br>170M4806<br>170M4807<br>170M4808<br>170M4809<br>170M4810<br>170M4811<br>170M4812<br>170M4813<br>170M4814<br>170M4815|170M4822<br>170M4823<br>170M4824<br>170M4825<br>170M4826<br>170M4827<br>170M4828<br>170M4829<br>170M4830<br>170M4831<br>170M4832<br>170M4833<br>170M4834<br>170M4835|00|1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>900|20<br>25<br>32<br>35<br>40<br>50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315|20<br>30<br>55<br>69<br>100<br>170<br>280<br>500<br>950<br>1500<br>3000<br>5600<br>10000<br>18000|140<br>210<br>390<br>500<br>690<br>1200<br>2000<br>3500<br>6850<br>11500<br>22000<br>40500<br>74000<br>115000|5<br>7<br>9<br>10<br>11<br>13<br>18<br>22<br>25<br>33<br>37<br>40<br>48<br>58|
|• Watts loss provided at rated current.||||||||
• Microswitch ordered separately. See accessories on page 212-213.
## **Size 00 — 20-315A: 1000V Time-Current Curve**
**==> picture [232 x 296] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>10 [3 ]<br>10 [2]<br>10<br>1s<br>10 [-1 ]<br>10 [-2 ]<br>10 [-3 ]<br>10 [-4 ]<br>10 10 [2 ] 10 [3 ] 10 [4]<br>Prospective Current In Amp RMS<br>125A 200A 315A<br>*<br>100A 160A 250A<br>25A 35A 50A 80A<br>20A 32A 40A 63A<br>Virtual Pre-arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [240 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4 ]<br>10 [3 ]<br>10 [2]<br>2x10<br>10 10 [2 ] 10 [3 ] 10 [4 ] Amp 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMSProspective Short-Circuit Current symmetrical RMS<br>* 315A fuse is derated to 900V<br>315A 250A<br>200A 160A<br>125A 100A<br>80A 63A<br>50A 40A<br>35A 32A<br>25A 20A<br>Peak Let-Through Current In Amperes<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**173**
**High Speed Fuses**
## **Square Body DIN 43 653 — 1000V (IEC): 50-1400A**
## **1000V (IEC) 50-1400A**
**==> picture [109 x 110] intentionally omitted <==**
## **Specifications**
**Description:** Square body mount high speed fuses. **Dimensions:** See dimensions illustrations.
Ratings: Volts: — 1000Vac. Amps:— 50-1400A
IR: — 125kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
## **Electrical**
## **Characteristics**
**==> picture [248 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
Total clearing I [2] t 1,5 K<br>The total clearing I [2] t at *<br>1,0<br>rated voltage and at power<br>factor of 15% are given in<br>the electrical 0,5<br>characteristics. For other 0,4<br>voltages, the clearing I [2] t is 0,3<br>found by multiplying by<br>correction factor, K, given 0,2<br>as a function of applied Eg<br>500 600 700 800 900 1000<br>working voltage, Eg, (rms).<br>*Rated voltage 900V<br>**----- End of picture text -----**<br>
**==> picture [248 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 2,53 UL<br>This curve gives the peak 2<br>1,8<br>arc voltage, UL, which 1,6<br>1,4<br>may appear across the 1,2<br>10 [3]<br>fuse during its operation 8<br>as a function of the 7<br>6<br>applied working voltage 5<br>Eg, (rms) at a power factor 4<br>of 15%. 3 Eg<br>5 00 60 0 7 00 800 9 00 10 0 0<br>Power Losses<br>1,0<br>Watts loss at rated current 0,8 Kp<br>is given in the electrical 0,70,6<br>characteristics. The curve 0,5<br>allows the calculation of 0,4<br>the power losses at load 0,3<br>currents lower than the<br>0,2<br>rated current. The<br>0,15<br>correction factor, Kp, isgiven as a function of the 0,130 40 50 60 70 80 90 100%Ib<br>RMS load current, Ib, in %<br>of the rated current.<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See pages 150 (690V/700V) and 187 (1250V/1300V)
## **Dimensions - mm**
|Type –KN/110|Type –KN/110|Type –KN/110|||||||
|---|---|---|---|---|---|---|---|---|
|**Size**|**A**|**B**|**C**|**Max D1 E**||**G**|**H**|**I**|
|1*KN/110|80|138|108|61|43|6|22|11|
|1KN/110|80|138|108|69|51|6|25|11|
|2KN/110|80|138|108|77|59|6|25|11|
|3KN/110|81|139|108|92|74|6|30|11|
|Type –TN/110|Type –TN/110|Type –TN/110|||||||
|---|---|---|---|---|---|---|---|---|
|**Size**|**A**|**B**|**C**|**Max D2 E**||**G**|**H**|**I**|
|1*TN/110|80|138|108|61|43|6|22|11|
|1TN/110|80|138|108|69|51|6|25|11|
|2TN/110|80|138|108|75|59|6|25|11|
|3TN/110|81|139|108|90|74|6|30|11|
|1mm = 0.0394”||/ 1” =|25.4mm||||||
## Type-KN/110
Type-TN/110
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**174**
**High Speed Fuses**
## **Square Body DIN 43 653 — 1000V (IEC): 50-1400A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|||||||
|---|---|---|---|---|---|---|---|
|**Catalog Numbers**|||**Electrical Characteristics**|||||
|<br>**-KN/110**<br>**Type K**<br>**Indicator for**<br>**Micro**|<br>**-TN/110**<br>**Type T**<br>**Indicator for**<br>**Micro**|**Size**|**Rated**<br>**Voltage**|**Rated**<br>**Current**<br>**RMS**<br>**Amps**|**I2t (A2 Sec)**||**Watts**<br>**Loss**|
||||||<br>**Pre-arc**|**Clearing**<br>**at Rated**<br>**Voltage**||
|170M3965<br>170M3966<br>170M3967<br>170M3968<br>170M3969<br>170M3970<br>170M3971<br>170M3972<br>170M3973<br>170M3974<br>170M3975|170M3981<br>170M3982<br>170M3983<br>170M3984<br>170M3985<br>170M3986<br>170M3987<br>170M3988<br>170M3989<br>170M3990<br>170M3991|1*|1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000|50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400|135<br>215<br>460<br>860<br>1450<br>2850<br>4950<br>9550<br>21500<br>29000<br>42000|815<br>1300<br>2750<br>5100<br>8600<br>17500<br>29500<br>57000<br>130000<br>175000<br>250000|20<br>25<br>30<br>35<br>40<br>45<br>48<br>50<br>60<br>65<br>70|
|170M4965<br>170M4966<br>170M4967<br>170M4968<br>170M4969<br>170M4970<br>170M4971<br>170M4972<br>170M4973<br>170M4974|170M4980<br>170M4981<br>170M4982<br>170M4983<br>170M4984<br>170M4985<br>170M4986<br>170M4987<br>170M4988<br>170M4989|1|1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000|160<br>200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630|2200<br>4150<br>7750<br>16500<br>21500<br>31000<br>44500<br>63000<br>84500<br>125000|13500<br>24500<br>46000<br>98500<br>130000<br>185000<br>265000<br>375000<br>500000<br>755000|40<br>45<br>52<br>60<br>65<br>70<br>80<br>85<br>90<br>98|
|170M5966<br>170M5967<br>170M5968<br>170M5969<br>170M5970<br>170M5971<br>170M5972<br>170M5973<br>170M5974<br>170M5975|170M5981<br>170M5982<br>170M5983<br>170M5984<br>170M5985<br>170M5986<br>170M5987<br>170M5988<br>170M5989<br>170M5990|2|1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000|250<br>315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800|6750<br>13500<br>16500<br>26000<br>35500<br>49500<br>66000<br>93500<br>130000<br>195000|40000<br>81500<br>99000<br>155000<br>210000<br>295000<br>390000<br>555000<br>770000<br>1200000|65<br>75<br>80<br>85<br>90<br>95<br>100<br>110<br>115<br>125|
|170M8614<br>170M8615<br>170M8616<br>170M8617<br>170M8618<br>170M8619<br>170M8620<br>170M8621<br>170M8622<br>170M8623<br>170M8624<br>170M8625<br>170M8626<br>170M8627|170M8629<br>170M8630<br>170M8631<br>170M8632<br>170M8633<br>170M8634<br>170M8635<br>170M8636<br>170M8637<br>170M8638<br>170M8639<br>170M8640<br>170M8641<br>170M8642|3|1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>900|315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250<br>1400|9200<br>13000<br>19000<br>27000<br>37500<br>52000<br>82500<br>115000<br>170000<br>250000<br>340000<br>460000<br>575000<br>795000|54500<br>77500<br>115000<br>160000<br>225000<br>310000<br>490000<br>700000<br>1050000<br>1500000<br>2050000<br>2750000<br>3400000<br>4200000|90<br>95<br>105<br>107<br>110<br>115<br>120<br>125<br>135<br>145<br>150<br>155<br>175<br>185|
- Watts loss provided at rated current.
- Microswitch ordered separately. See accessories on page 212-213.
- For fuse curves see pages 180 and 181.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**175**
**High Speed Fuses**
## **Square Body Flush End Contact — 1000V (IEC): 50–1400A**
## **1000V (IEC) 50–1400A**
## **Specifications**
**Description:** Square body flush end contact high speed fuses. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 1000Vac. Amps: — 50-1400A
IR: — 150kA (Est. 300kA) RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
## **Electrical**
**==> picture [128 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
1,5<br>K<br>1,0 | *<br>rr rrfj edfdee eee<br>es ee<br>0,5 ee ee ee<br>0,4 | | | |<br>0,3 Pot<br>0,2 || | tT<br>Eg<br>500 | ot 600 700 tt|tT 800 900 1000<br>*Rated voltage 900V<br>**----- End of picture text -----**<br>
## **Characteristics**
## **Total clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Arc Voltage**
**==> picture [245 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 2,53 rs UL<br>This curve gives the peak 2<br>1,8 pf {| [{|_|]<br>arc voltage, UL, which may 1,6<br>1,4<br>appear across the fuse 1,2 ==S==<br>10 [3]<br>during its operation as a 8<br>function of the applied 7<br>6 oe<br>working voltage Eg, (rms) 5 a<br>at a power factor of 15%. 4 a<br>3 Eg<br>5 00 60 0 7 00 800 9 00 10 0 0<br>Power Losses 1,00,8 | Kp EE =EF4]<br>Watts loss at rated currentis given in the electricalcharacteristics. The curve 0,70,60,50,4 aPrapt | tp yt<br>allows the calculation of 0,3 Lt | yt tf<br>the power losses at load<br>0,2<br>currents lower than the<br>0,15<br>rated current. The<br>Ib<br>correction factor, Kp, is 0,130 HEHE 40 50 60 70 80 90 100%<br>given as a function of the YET ETT<br>RMS load current, Ib, in %<br>of the rated current.<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See pages 152 (690V/700V) and 189 (1250V/1300V)
## **Dimensions - mm**
Type –BKN/- and –GKN/-
|**Size**|**A**|**B**|**Max D E**|**Max D E**|**F**|**F* (in)**|**Min G**|**H**|
|---|---|---|---|---|---|---|---|---|
|1*BKN/75+GKN/75|72.5|74|61|43|M8|5⁄16” –18 UNC-2B|5|ø17.5|
|1BKN/75+GKN/75|73.2|74|69|52|M8|5⁄16” –18 UNC-2B|8|ø20|
|2BKN/75+GKN/75|73.2|74.4|77|59|M10|3⁄8” –16 UNC-2B|10|ø24|
|3BKN/75+GKN/75|73.3|75.4|92|74|M12|1⁄2” –13 UNC-2B|10|ø30|
|3BKN/90+GKN/90|80.3|91.4|92|74|M12|1⁄2” –13 UNC-2B|10|ø30|
|* Valid for fuses type –GKN/-.|||||||||
|1mm = 0.0394” / 1” = 25.4mm|||||||||
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**176**
**High Speed Fuses**
## **Square Body Flush End Contact — 1000V (IEC): 50–1400A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|||||||
|---|---|---|---|---|---|---|---|
|**Catalog Numbers**|||**Electrical Characteristics**|||||
|<br>**-BKN/-**<br>**Type K**<br>**Indicator for **<br>**Micro**|<br>**-GKN/-**<br>**Type K**<br> **Indicator for**<br>**Micro**|**Size**|**Rated**<br>**Voltage**|**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**||**Watts**<br>**Loss**|
||||||<br>**Pre-arc**|<br>**Clearing**<br>**at Rated**<br>**Voltage**||
|170M3951<br>170M3952<br>170M3953<br>170M3954<br>170M3955<br>170M3956<br>170M3957<br>170M3958<br>170M3959<br>170M3960<br>170M3961|170M3921<br>170M3922<br>170M3923<br>170M3924<br>170M3925<br>170M3926<br>170M3927<br>170M3928<br>170M3929<br>170M3930<br>170M3931|1*|1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000|50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400|135<br>215<br>460<br>860<br>1450<br>2850<br>4950<br>9550<br>21500<br>29000<br>42000|815<br>1300<br>2750<br>5100<br>8600<br>17500<br>29500<br>57000<br>130000<br>175000<br>250000|20<br>25<br>30<br>35<br>40<br>45<br>48<br>50<br>60<br>65<br>70|
|170M4951<br>170M4952<br>170M4953<br>170M4954<br>170M4955<br>170M4956<br>170M4957<br>170M4958<br>170M4959<br>170M4960|170M4921<br>170M4922<br>170M4923<br>170M4924<br>170M4925<br>170M4926<br>170M4927<br>170M4928<br>170M4929<br>170M4930|1|1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000|160<br>200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630|2200<br>4150<br>7750<br>16500<br>21500<br>31000<br>44500<br>63000<br>84500<br>125000|13500<br>24500<br>46000<br>98500<br>130000<br>185000<br>265000<br>375000<br>500000<br>755000|40<br>45<br>52<br>60<br>65<br>70<br>80<br>85<br>90<br>98|
|170M5952<br>170M5953<br>170M5954<br>170M5955<br>170M5956<br>170M5957<br>170M5958<br>170M5959<br>170M5960<br>170M5961|170M5922<br>170M5923<br>170M5924<br>170M5925<br>170M5926<br>170M5927<br>170M5928<br>170M5929<br>170M5930<br>170M5931|2|1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000|250<br>315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800|6750<br>13500<br>16500<br>26000<br>35500<br>49500<br>66000<br>93500<br>130000<br>195000|40000<br>81500<br>99000<br>155000<br>210000<br>295000<br>390000<br>555000<br>770000<br>1200000|65<br>75<br>80<br>85<br>90<br>95<br>100<br>110<br>115<br>125|
|170M8600<br>170M8601<br>170M8602<br>170M8603<br>170M8604<br>170M8605<br>170M8606<br>170M8607<br>170M8608<br>170M8609<br>170M8610<br>170M8611<br>170M8612** <br>170M8613**|170M8500<br>170M8501<br>170M8502<br>170M8503<br>170M8504<br>170M8505<br>170M8506<br>170M8507<br>170M8508<br>170M8509<br>170M8510<br>170M8511<br> 170M8512**<br> 170M8513**|3|1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>1000<br>900|315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250<br>1400|9200<br>13000<br>19000<br>27000<br>37500<br>52000<br>82500<br>115000<br>170000<br>250000<br>340000<br>460000<br>575000<br>795000|54500<br>77500<br>115000<br>160000<br>225000<br>310000<br>490000<br>700000<br>1050000<br>1500000<br>2050000<br>2750000<br>3400000<br>4200000|90<br>95<br>105<br>107<br>110<br>115<br>120<br>125<br>135<br>145<br>150<br>155<br>175<br>185|
**Overall length is 90mm, for all other fuses the overall length is 75mm.
- Watts loss provided at rated current.
- Microswitch ordered separately. See accessories on page 212-213.
- For fuse curves see pages 180 and 181.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**177**
**High Speed Fuses**
## **Square Body US style — 1000V (IEC): 50-1400A**
## **1000V (IEC) 50-1400A**
## **Specifications**
**Description:** Square body US style high speed fuses. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 1000Vac. Amps: — 50-1400A
IR: — 150kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
## **Electrical Characteristics**
**==> picture [250 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
Characteristics<br>Total clearing I [[2]] t 1,5 K<br>The total clearing I [2] t at rated 1,0 *<br>coo<br>voltage and at power factor<br>of 15% are given in the<br>electrical characteristics. For 0,5 =<br>other voltages, the clearing 0,4 LF | |ft<br>I [2] t is found by multiplying by 0,3 TTT<br>correction factor, K, given as<br>Ft<br>a function of applied 0,2 Eg<br>Pot || |ft tl|<br>working voltage, Eg, (rms). 500 600 700 800 900 1000<br>*Rated voltage 900V<br>**----- End of picture text -----**<br>
## **Total clearing I[[2]] t**
## **Arc Voltage**
**==> picture [247 x 247] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>This curve gives the peak 2,52 ee UL ee ee<br>arc voltage, UL, which 1,81,6<br>may appear across the 1,4<br>1,2<br>fuse during its operation 10 [3]<br>as a function of the applied 8<br>7<br>working voltage Eg, (rms) 6 ——<—<——<br>at a power factor of 15%. 5 ee eeee<br>4 a<br>3 Eg<br>5 00 60 0 7 00 800 9 00 10 0 0<br>Power Losses<br>1,0<br>K<br>Watts loss at rated current 0,8 | p He+-++—+ +4<br>is given in the electrical 0,7 ee<br>0,6<br>characteristics. The curveallows the calculation of 0,50,4 Lee| ee| | ytee| |<br>the power losses at load 0,3<br>currents lower than the<br>rated current. The 0,2<br>correction factor, Kp, is 0,15 iieanie<br>given as a function of the 0,1 YELLE Ib<br>RMS load current, Ib, in % 30 HHH 40 50 60 70 80 90 100%<br>of the rated current.<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
## **Dimensions - mm**
- Reduced voltage starters
Type –FKE/115
|**Size**|**B**|**C1**|**C2**|**D**|**E**|**H**|**I**|
|---|---|---|---|---|---|---|---|
|1*FKE/115|156|130|101|59|45|20|10|
|1FKE/115<br>2FKE/115|160<br>160|127<br>127|102<br>102|69<br>77|53<br>61|25<br>25|14<br>14|
|3FKE/115|159|128|101|92|76|36|16|
## **For Other Voltage Ratings in This Body Style**
- See pages 154 (690V/700V) and 191 (1250V/1300)
1mm = 0.0394” / 1” = 25.4mm
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**178**
**High Speed Fuses**
## **Square Body US style — 1000V (IEC): 50-1400A**
## **Catalog Numbers**
|**Catalog Numbers**|**Size**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|
|<br>**-FKE/115**<br>**Type K**<br>**Indicator for**<br>**Micro**||||||
|||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**||**Watts**<br>**Loss**|
||||**Pre-arc**|**Clearing**<br>**at 1000V**||
|170M3531<br>170M3532<br>170M3533<br>170M3534<br>170M3535<br>170M3536<br>170M3537<br>170M3538<br>170M3539<br>170M3540<br>170M3541|1*|50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400|135<br>215<br>460<br>860<br>1450<br>2850<br>4950<br>9550<br>21500<br>29000<br>42000|815<br>1300<br>2750<br>5100<br>8600<br>17500<br>29500<br>57000<br>130000<br>175000<br>250000|20<br>25<br>30<br>35<br>40<br>45<br>48<br>50<br>60<br>65<br>70|
|170M4531<br>170M4532<br>170M4533<br>170M4534<br>170M4535<br>170M4536<br>170M4537<br>170M4538<br>170M4539<br>170M4540|1|160<br>200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630|2200<br>4150<br>7750<br>16500<br>21500<br>31000<br>44500<br>63000<br>84500<br>125000|13500<br>24500<br>46000<br>98500<br>130000<br>185000<br>265000<br>375000<br>500000<br>755000|40<br>45<br>52<br>60<br>65<br>70<br>80<br>85<br>90<br>98|
|170M5531<br>170M5532<br>170M5533<br>170M5534<br>170M5535<br>170M5536<br>170M5537<br>170M5538<br>170M5539<br>170M5540|2|250<br>315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800|6750<br>13500<br>16500<br>26000<br>35500<br>49500<br>66000<br>93500<br>130000<br>195000|40000<br>81500<br>99000<br>155000<br>210000<br>295000<br>390000<br>555000<br>770000<br>1200000|65<br>75<br>80<br>85<br>90<br>95<br>100<br>110<br>115<br>125|
|170M8531<br>170M8532<br>170M8533<br>170M8534<br>170M8535<br>170M8536<br>170M8537<br>170M8538<br>170M8539<br>170M8540<br>170M8541<br>170M8542<br>170M8543<br>170M8544*|3|315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250<br>1400|9200<br>13000<br>19000<br>27000<br>37500<br>52000<br>82500<br>115000<br>170000<br>250000<br>340000<br>460000<br>575000<br>795000|54500<br>77500<br>115000<br>160000<br>225000<br>310000<br>490000<br>700000<br>1050000<br>1500000<br>2050000<br>2750000<br>3400000<br>4200000*|90<br>95<br>105<br>107<br>110<br>115<br>120<br>125<br>135<br>145<br>150<br>155<br>175<br>185|
* Rated voltage 900V.
- Watts loss provided at rated current.
- Microswitch ordered separately. See accessories on pages 212-213.
- For fuse curves see pages 180 and 181.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**179**
**High Speed Fuses**
## **Square Body, US style - Size 1*, 1 — 1000V (IEC): 50-1400A**
## **Size 1* — 50-400A: 1000V Time-Current Curve**
## **Size 1 — 160-630A: 1000V Time-Current Curve**
**==> picture [500 x 528] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>10 [3 ]<br>10 [2]<br>10<br>1s<br>1s<br>10 [-1 ]<br>10 [-1 ]<br>10 [-2]<br>10 [-2 ]<br>10 [-3 ] 10 [-3 ]<br>10 [-4 ] 10 [-4 ]<br>5x10 [1 ] 10 [2] 10 [3 ] 10 [4 ] 5x10 [4] 10 [2] 10 [3 ] 10 [4 ] 10 [5]<br>Prospective Current In Amp RMS<br>Prospective Current In Amp RMS<br>Peak Let-Through Curve Peak Let-Through Curve<br>10 [5] 10 [5]<br>10 [4 ] 10 [4 ]<br>10 [3] 10 [3]<br>2x10 [2] 2x10 [2]<br>10 [2] 10 [3 ] 10 [4 ] 10 [5 ] Amp 10 [6] 10 [2] 10 [3 ] 10 [4 ] 10 [5 ] Amp 10 [6]<br>Prospective Short-Circuit Current Symmetrical RMS Prospective Short-Circuit Current Symmetrical RMS<br>400A<br>350A 315A<br>250A 200A<br>160A 125A<br>100A 80A<br>630A 50A<br>630A 550A<br>500A 450A<br>400A 350A<br>315A 250A<br>200A 160A<br>200A 315A 400A 200A 400A 500A 630A<br>100A 160A 250A 350A<br>315A<br>250A 350A 450A 550A<br>50A 80A 125A<br>63A<br>160A<br>Virtual Pre-arcing Time In Seconds<br>Virtual Pre-arcing Time In Seconds<br>Peak Let-Through Current In Amperes Peak Let-Through Current In Amperes<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**180**
**High Speed Fuses**
## **Square Body, US style - Size 2, 3 — 1000V (IEC): 50-1400A**
## **Size 2 — 250-800A: 1000V Time-Current Curve**
## **Size 3 — 315-1400A: 1000V Time-Current Curve**
**==> picture [231 x 296] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>10 [3 ]<br>10 [2]<br>10<br>1s<br>10 [-1 ]<br>10 [-2 ]<br>10 [-3 ]<br>10 [-4 ]<br>10 [2] 10 [3 ] 10 [4 ] 10 [5]<br>Prospective Current In Amp RMS<br>250A 350A 450A 550A 700A<br>315A 400A 500A 630A 800A<br>Virtual Pre-arcing Time In Seconds<br>**----- End of picture text -----**<br>
**==> picture [231 x 296] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>10 [3 ]<br>10 [2]<br>10<br>1s<br>10 [-1 ]<br>10 [-2 ]<br>10 [-3 ]<br>10 [-4 ]<br>10 [2] 10 [3 ] 10 [4 ] 10 [5]<br>Prospective Current In Amp RMS<br>350A 700A 900A 1100A 1400A*<br>800A 1000A 1250A<br>450A 550A<br>315A 400A 500A 630A<br>Virtual Pre-arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [221 x 158] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [5]<br>10 [4 ]<br>10 [3]<br>2x10 [2 ]<br>10 [2] 10 [3 ] 10 [4 ] 10 [5 ] Amp 10 [6]<br>Prospective Short-Circuit Current Symmetrical RMS<br>800A 700A<br>630A<br>500A 550A 450A<br>400A 315A 350A 250A<br>Peak Let-Through Current In Amperes<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [220 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [5]<br>10 [4 ]<br>10 [3]<br>2x10 [2 ]<br>10 [2] 10 [3 ] 10 [4 ] 10 [5 ] Amp 10 [6]<br>Prospective Short-Circuit Current Symmetrical RMS<br>1400A1100A * 1250A 1000A<br>900A 800A<br>700A 630A<br>550A 500A<br>450A 400A<br>350A 315A<br>Peak Let-Through Current In Amperes<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**181**
**High Speed Fuses**
## **Square Body Flush End Contact Size 4 — 1000V (IEC): 1000-2700A**
## **1000V (IEC) 1000-2700A**
## **Specifications**
**Description:** Square body DIN 43 620 blade style high speed fuses.
**Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 1000Vac (IEC) Amps: — 1000-2700A
IR: — 125kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
## **Electrical Characteristics**
## **Total clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Arc Voltage**
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied , working voltage Eg (rms) at a power factor of 15%.
## **Power Losses**
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See pages 163 (690V/700V) and 195 (1250V)
## **Catalog Numbers**
**==> picture [333 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog Number Electrical Characteristics<br>-BKN/95 -SBKN/90 Rated Rated I2t (A2Sec) Watt<br>Fuse Type K Type K Voltage Current Clearing Loss<br>Size Indicator Indicator (V) RMS-Amp Pre-arc at 1000V (W)<br>— 170M7542 1000 180000 1100000 195<br>— 170M7031 1100 250000 1500000 200<br>170M7636 170M7548 1500 600000 3600000 250<br>170M7639 170M7034 1700 850000 5000000 260<br>4 170M7963 170M7544 1000 2000 1450000 8600000 270<br>170M7090 170M7035 2200 2000000 12000000 280<br>170M7640 170M7036 2500 3000000 18000000 295<br>170M7658 170M7037 2700 3700000 22000000 310<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**182**
**High Speed Fuses**
## **Square Body Flush End Contact Size 4 — 1000V (IEC): 1000-2700A**
## **Dimensions - mm**
Type 4BKN/ 95
Type 4SBKN/ 95
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**183**
**High Speed Fuses**
## **Square Body Flush End Contact Size 4 — 1000V (IEC): 1000-2700A**
## **Size 4 — 1000-2700A: 660V**
**Time-Current Curve**
**==> picture [125 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**Data Sheet: Available upon request**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**184**
**High Speed Fuses**
## **Square Body Flush End Contact Size 24 — 1000V (IEC): 2000-5000A**
## **1000V (IEC) 2000-5000A**
**Arc Voltage**
## **Specifications**
**Description:** High speed square body fuses, for the protection of the power rectifier section of the equipment.
**Dimensions:** See dimensions illustration.
**Ratings:** Volts: — 1000Vac Amps: — 2000-5000A IR: — 300kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
**==> picture [172 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
B00 B00 7000 200 #400 600 Boo<br>2000-3500A 4200-5000A<br>**----- End of picture text -----**<br>
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg , (rms) at a power factor of 15%.
## **Electrical Characteristics**
## **Total clearing I[2] t**
**==> picture [174 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
2000-3500A 4200-5000A<br>**----- End of picture text -----**<br>
**Power Losses**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Typical Applications**
## **Features and Benefits**
• Power converters/rectifiers
- Low watts loss
- Reduced voltage starters
- Superior cycling capability
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
**For Other Voltage Ratings in This Body Style** • See pages 165 (660V) and 198 (1250V)
**Dimensions - mm**
## **Catalog Numbers**
|**Fuse**<br>**Size**|**Cat. Number**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|---|
||**-BKN/85**<br>**Type K**<br>**Indicator**|**Rated**<br>**Voltage**<br>**(V)**|**Rated**<br>**Current**<br>**RMS-Amp**|**I**<br>**2t (A**<br>**2Sec)**||**Watt**<br>**Loss**<br>**(W)**|
|||||**t (A**<br><br>**Pre-arc**|**Sec)**<br>**Clearing at**<br>**1000V**||
|24|170M7608<br>170M7680<br>170M7567<br>170M7568<br>170M7569<br>170M7498<br>170M7488<br>170M7622|1000|2000<br>3000<br>3200<br>3500<br>4000<br>4200<br>4500<br>5000|885000<br>2900000<br>3300000<br>4500000<br>6800000<br>8000000<br>10000000<br>14000000|5700000<br>19000000<br>20000000<br>27000000<br>40000000<br>47500000<br>59000000<br>82500000|345<br>430<br>440<br>450<br>475<br>485<br>495<br>540|
Data Sheet: 170K7540, 170K8514
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**185**
## **High Speed Fuses** by E.TeN **Square Body Flush End Contact Size 24 — 1000V (IEC): 2000-5000A Size 24 — 2000-3500A: 1000V Size 24 — 4200-5000A: 1000V**
**Size 24 — 2000-3500A: 1000V Size 24 — 4200-5000A: 1000V Time-Current Curve Time-Current Curve**
**==> picture [124 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**==> picture [125 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**Peak Let-Through Curve**
## **Peak Let-Through Curve**
**==> picture [145 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data Sheet: Available upon request<br>**----- End of picture text -----**<br>
**==> picture [145 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data Sheet: Available upon request<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**186**
**High Speed Fuses** a
## **Square Body DIN 43 653 — 1250V/1300V (IEC/UL): 50-1400A**
## **1250V/1300V (IEC/UL) 50-1400A**
## **Arc Voltage**
**Arc Voltage** 3 2.5 UL This curve gives the peak eeeoe arc voltage, UL, which 1.8 may appear across the 1.4 fuse during its operation 10[3] as a function of theapplied 8 working voltage, Eg, (rms) 6 at a power factor of 15%. 5 = 4 ee T **Power Losses** 3 Eg 400 600 800 1000 1200 1400 Watts loss at rated current “ is given in the electrical 1.0 characteristics. The curve 0.8 te Kp allows the calculation of 0.6 St ea the power losses at load 0.5 currents lower than the 0.4 | [| | | hy ft rated current. The correction factor, Kp, is 0.3 (CTYTAT given as a function of the 0.2 RMS load current, Ib, in % of the rated current. 0.1 ALLEL Ib 30 Att 40 50 60 70 80 90 100%
## **Specifications**
**Description:** Square body DIN 43 653 stud-mount high speed fuses.
**Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 1250Vac (IEC) — 1300Vac (UL)
Amps: — 50-1400A
IR: — 100kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2, CSA Certified: Class 53787, File 1422-30.
## **Electrical Characteristics**
**==> picture [141 x 203] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.5<br>K<br>1.25 ee,<br>1.0<br>———<br>0.5 ee<br>0.4 ee ee eeee<br>0.3 | | | UT<br>0.2 | | Tf yl<br>E<br>a g<br>400 600 800 1000 1200 1400<br>Dashed lines (- - - - - -) apply to the following<br>amperages:.<br>Size Amps.<br>1* 400A<br>1 500-630A<br>2 630-1000A<br>3 800-1400A<br>**----- End of picture text -----**<br>
## **Total Clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See pages 150 (690V/700V) and 176 (1000V)
## **Dimensions - mm**
**==> picture [253 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type -/110, -TN/110<br>Size A B D** E H 108<br>1* 80 138 58 45 20 A<br>1 80 138 66 53 25<br>2 80 138 75 61 25<br>3 ee 81 139 90 76 30<br>**Microswitch.<br>1mm = 0.0394” / 1” = 25.4mm<br>H<br>| 11 le<br>D<br>E B<br>6<br>E<br>**----- End of picture text -----**<br>
**==> picture [219 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type -KN/110<br>Size A B D E H<br>1* 80 138 58 45 20<br>1 80 138 66 53 25<br>2 80 138 75 61 25<br>3 OO 81 139 90 76 30<br>1mm = 0.0394” / 1” = 25.4mm<br>C<br>A<br>H<br>11<br>D<br>E B<br>6<br>E<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**187**
**High Speed Fuses**
## **Square Body DIN 43 653 — 1250V/1300V (IEC/UL): 50-1400A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**||||||||
|---|---|---|---|---|---|---|---|---|
|**Catalog Numbers**|||||||||
|<br>**-/110**<br>**Visual**<br>**Indicator**|<br>**-TN/110**<br>**Type T**<br>**Indicator**<br>**for Micro**|**-KN/110**<br>**Type K**<br>**Indicator**<br>**for Micro**|**Size**||**Electrical Characteristics**||||
|||||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**|||**Watts**<br>**Loss**|
||||||**Pre-arc**|**Clearing**<br>**at 1000V**|**Clearing**<br>**at 1250V**||
|170M3138<br>170M3139<br>170M3140<br>170M3141<br>170M3142<br>170M3143<br>170M3144<br>170M3145<br>170M3146<br>170M3147<br>170M3148|170M3188<br>170M3189<br>170M3190<br>170M3191<br>170M3192<br>170M3193<br>170M3194<br>170M3195<br>170M3196<br>170M3197<br>170M3198|170M3238<br>170M3239<br>170M3240<br>170M3241<br>170M3242<br>170M3243<br>170M3244<br>170M3245<br>170M3246<br>170M3247<br>170M3248|1*|50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400|135<br>215<br>420<br>750<br>1450<br>2600<br>5150<br>9200<br>18500<br>27000<br>53000|815<br>1300<br>2500<br>4450<br>9000<br>16000<br>31000<br>54500<br>115000<br>165000<br>265000|1100<br>1750<br>3350<br>5950<br>11500<br>21000<br>41000<br>73000<br>150000<br>220000<br>335000|15<br>20<br>25<br>30<br>35<br>40<br>45<br>55<br>60<br>65<br>70|
|170M4138<br>170M4139<br>170M4140<br>170M4141<br>170M4142<br>170M4143<br>170M4144<br>170M4145<br>170M4146<br>170M4147|170M4188<br>170M4189<br>170M4190<br>170M4191<br>170M4192<br>170M4193<br>170M4194<br>170M4195<br>170M4196<br>170M4197|170M4238<br>170M4239<br>170M4240<br>170M4241<br>170M4242<br>170M4243<br>170M4244<br>170M4245<br>170M4246<br>170M4247|1|160<br>200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630†|1900<br>3800<br>7750<br>15000<br>20000<br>29500<br>42000<br>69500<br>95000<br>130000|11500<br>22500<br>46000<br>90000<br>125000<br>175000<br>250000<br>340000<br>465000<br>660000|15500<br>30000<br>61500<br>120000<br>165000<br>235000<br>335000<br>435000<br>590000|45<br>50<br>60<br>65<br>70<br>75<br>80<br>85<br>95<br>100|
|170M5138<br>170M5139<br>170M5140<br>170M5141<br>170M5142<br>170M5143<br>170M5144<br>170M5145<br>170M5146<br>170M5147<br>170M5148<br>170M5149<br>170M5150|170M5188<br>170M5189<br>170M5190<br>170M5191<br>170M5192<br>170M5193<br>170M5194<br>170M5195<br>170M5196<br>170M5197<br>170M5198<br>170M5199<br>170M5200|170M5238<br>170M5239<br>170M5240<br>170M5241<br>170M5242<br>170M5243<br>170M5244<br>170M5245<br>170M5246<br>170M5247<br>170M5248<br>170M5249<br>170M5250|2|250<br>280<br>315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>900†<br>1000†|6500<br>9350<br>13000<br>16500<br>23000<br>34000<br>48000<br>62000<br>115000<br>160000<br>245000<br>360000<br>480000|38500<br>55500<br>77500<br>97500<br>140000<br>205000<br>285000<br>370000<br>575000<br>795000<br>1200000<br>1750000<br>2350000|51500<br>74500<br>105000<br>135000<br>180000<br>270000<br>380000<br>495000<br>730000<br>1050000<br>1550000|65<br>70<br>75<br>80<br>85<br>90<br>95<br>100<br>110<br>115<br>120<br>125<br>135|
|170M6138<br>170M6139<br>170M6140<br>170M6141<br>170M6142<br>170M6143<br>170M6144<br>170M6145<br>170M6146<br>170M6147<br>170M6148<br>170M6149<br>170M6150<br>170M6151|170M6188<br>170M6189<br>170M6190<br>170M6191<br>170M6192<br>170M6193<br>170M6194<br>170M6195<br>170M6196<br>170M6197<br>170M6198<br>170M6199<br>170M6200<br>170M6201|170M6238<br>170M6239<br>170M6240<br>170M6241<br>170M6242<br>170M6243<br>170M6244<br>170M6245<br>170M6246<br>170M6247<br>170M6248<br>170M6249<br>170M6250<br>170M6251|3|315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800‡<br>900‡<br>1000‡<br>1100‡<br>1250†<br>1400†|9500<br>13500<br>19500<br>31000<br>39000<br>55000<br>83500<br>115000<br>205000<br>305000<br>450000<br>575000<br>810000<br>1250000|58000<br>81500<br>120000<br>185000<br>235000<br>325000<br>495000<br>705000<br>995000<br>1500000<br>2150000<br>2800000<br>3950000<br>6000000|77500<br>110000<br>160000<br>245000<br>310000<br>435000<br>665000<br>940000<br>1300000<br>1900000<br>2750000<br>3600000|85<br>90<br>95<br>100<br>105<br>110<br>115<br>120<br>125<br>130<br>135<br>140<br>145<br>150|
- †Rated voltage (IEC) 1100V.
- ‡Rated voltage (IEC) 1250V.
- Watts loss provided at rated current.
- Microswitch indicator ordered separately. See accessories on pages 212-213. • For fuse curves see pages 193 and 194.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**188**
**High Speed Fuses**
## **Square Body Flush End Contact — 1250V/1300V (IEC/UL): 50-1400A**
## **1250V/1300V (IEC/UL) 50-1400A**
## **Specifications**
**Description:** Square body flush end contact high speed fuses. **Dimensions:** See dimensions illustrations.
## **Ratings:**
Volts: — 1250Vac (IEC) — 1300Vac (UL)
Amps: — 50-1400A
IR: — 100kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2, CSA Certified: Class 53787, File 1422-30.
## **Electrical**
## **Characteristics**
**==> picture [128 x 192] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.5<br>K<br>1.25<br>1.0<br>a<br>0.5 =o<br>0.4 Ff<br>0.3 | |<br>0.2 | {| ft| ftffff [Ut]<br>E<br>TET g<br>400 600 800 1000 1200 1400<br>Dashed lines (- - - - - -) apply to the<br>following amperages:.<br>Size Amps.<br>1* 400A<br>1 500-630A<br>2 630-1000A<br>3 800-1400A<br>**----- End of picture text -----**<br>
## **Total Clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Arc Voltage**
**==> picture [239 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 3<br>2.5 UL<br>This curve gives the peak ==<br>arc voltage, UL, which 1.8<br>may appear across the 1.4<br>fuse during its operation 10 [3]<br>as a function of theapplied 8<br>working voltage, Eg, (rms) 6<br>at a power factor of 15%. 5<br>4<br>E<br>3 es g<br>400 600 800 1000 1200 1400<br>Power Losses<br>1.0<br>Watts loss at rated current 0.8 SEES Kp<br>is given in the electrical 0.6 =e<br>allows the calculation ofcharacteristics. The curve 0.50.4 Pt | | Yt | |<br>the power losses at load 0.3 Pt tl|_Yi||<br>currents lower than the<br>[ALLE<br>rated current. The 0.2<br>correction factor, Kp, is<br>given as a function of the Ib<br>0.1 ALLELE<br>RMS load current, Ib, in % 30 ATF 40 50 60 70 80 90 100%<br>of the rated current.<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
**For Other Voltage Ratings in This Body Style**
- See pages 152 (690V/700V) and 176 (1000V)
## **Dimensions - mm**
Type -BKN/-, -GKN/-
**==> picture [329 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Size|Type|A|B|D|E|F|F** (in)|G|H|
|1*|BKN + GKN/75|74|75|59|45|M8|5⁄16”|- 18 UNC-2B|5|Ø17|
|1*|BKN/80|80|81|59|45|M8|5|Ø17|B|
|1|BKN + GKN/75|74|75|69|53|M8|5⁄16”|- 18 UNC-2B|8|Ø20|
|1|BKN/80|80|81|69|53|M8|8|Ø20|
|2|BKN + GKN/75|74|75|77|61|M10|3⁄8”|- 16 UNC-2B|10|Ø24|
|2|BKN/80|80|81|77|61|M10|10|Ø24|
|2|BKN + GKN/90|80|91|77|61|M10|3⁄8”|- 16 UNC-2B|10|Ø24|
|3|BKN + GKN/75|74|76|92|76|M12|1⁄2”|- 13 UNC-2B|10|Ø30|
|3|BKN/80|81|83|92|76|M12|10|Ø30|
|3|BKN + GKN/90|81|91|92|76|M12|1⁄2”|- 13 UNC-2B|10|Ø30|
|**Valid for fuses type -GKN/-.|
|1mm = 0.0394” / 1” = 25.4mm|D|
|E|A|
**----- End of picture text -----**<br>
**==> picture [205 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
D<br>E A<br>— F <—<br>E at oF H<br>J G ine<br>**----- End of picture text -----**<br>
1mm = 0.0394” / 1” = 25.4mm
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**189**
**High Speed Fuses**
## **Square Body Flush End Contact — 1250V/1300V (IEC/UL): 50-1400A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**Catalog Numbers**|||||||**Electrical Characteristics**||||
|<br>**-BKN/75**<br>**Type K**<br>**Indicator**<br>**for Micro**|<br>**-BKN/80**<br>**Type K**<br>**Indicator**<br>**for Micro**|**-BKN/90**<br>**Type K**<br>**Indicator**<br>**for Micro**|**-GKN/75**<br>**Type K**<br>**Indicator**<br>**for Micro**|**-GKN/90**<br>**Type K**<br>**Indicator**<br>**for Micro**|**Size **|**Rated**<br>**Current**<br>**RMS-**<br> **Amps**||||**Watts**<br>**Loss**|
||||||||**I2t (A2Sec)**||||
||||||||**Pre-arc**|**Clearing**<br>**at 1000V**|**Clearing**<br>**at 1250V**||
|170M3388<br>170M3389<br>170M3390<br>170M3391<br>170M3392<br>170M3393<br>170M3394<br>170M3395<br>170M3396<br>170M3397|170M3438<br>170M3439<br>170M3440<br>170M3441<br>170M3442<br>170M3443<br>170M3444<br>170M3445<br>170M3446<br>170M3447<br>170M3448||170M3488<br>170M3489<br>170M3490<br>170M3491<br>170M3492<br>170M3493<br>170M3494<br>170M3495<br>170M3496<br>170M3497||1*|50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350<br>400|135<br>215<br>420<br>750<br>1450<br>2600<br>5150<br>9200<br>18500<br>27000<br>53000|815<br>1300<br>2500<br>4450<br>9000<br>16000<br>31000<br>54500<br>115000<br>165000<br>265000|1100<br>1750<br>3350<br>5950<br>11500<br>21000<br>41000<br>73000<br>150000<br>220000<br>335000|15<br>20<br>25<br>30<br>35<br>40<br>45<br>55<br>60<br>65<br>70|
|170M4388<br>170M4389<br>170M4390<br>170M4391<br>170M4392<br>170M4393<br>170M4394<br>170M4395†<br>170M4396‡<br>170M4397‡|170M4438<br>170M4439<br>170M4440<br>170M4441<br>170M4442<br>170M4443<br>170M4444<br>170M4445<br>170M4446<br>170M4447†||170M4488<br>170M4489<br>170M4490<br>170M4491<br>170M4492<br>170M4493<br>170M4494<br>170M4495†<br>170M4496‡<br>170M4497‡||1|160<br>200<br>250<br>315<br>350<br>400<br>450<br>500<br>550<br>630|1900<br>3800<br>7750<br>15000<br>20000<br>29500<br>42000<br>69500<br>95000<br>130000|11500<br>22500<br>46000<br>90000<br>125000<br>175000<br>250000<br>340000<br>465000<br>660000|15500<br>30000<br>61500<br>120000<br>165000<br>235000<br>335000<br>435000<br>590000|45<br>50<br>60<br>65<br>70<br>75<br>80<br>85<br>95<br>100|
|170M5388<br>170M5389<br>170M5390<br>170M5391<br>170M5392<br>170M5393<br>170M5394<br>170M5395<br>170M5396†<br>170M5397‡<br>170M5398‡|170M5438<br>170M5439<br>170M5440<br>170M5441<br>170M5442<br>170M5443<br>170M5444<br>170M5445<br>170M5446<br>170M5447†<br>170M5448‡|170M5494<br>170M5495<br>170M5496<br>170M5497<br>170M5498<br>170M5499<br>170M5500|170M5588<br>170M5589<br>170M5590<br>170M5591<br>170M5592<br>170M5593<br>170M5594<br>170M5595<br>170M5596†<br>170M5597‡<br>170M5598‡|170M5644<br>170M5645<br>170M5646<br>170M5647<br>170M5648<br>170M5649<br>170M5650|2|250<br>280<br>315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>900†<br>1000†|6500<br>9350<br>13000<br>16500<br>23000<br>34000<br>48000<br>62000<br>115000<br>160000<br>245000<br>360000<br>480000|38500<br>55500<br>77500<br>97500<br>140000<br>205000<br>285000<br>370000<br>575000<br>795000<br>1200000<br>1750000<br>2350000|51500<br>74500<br>105000<br>135000<br>180000<br>270000<br>380000<br>495000<br>730000<br>1050000<br>1550000|65<br>70<br>75<br>80<br>85<br>90<br>95<br>100<br>110<br>115<br>120<br>125<br>135|
|170M6338<br>170M6339<br>170M6340<br>170M6341<br>170M6342<br>170M6343<br>170M6344<br>170M6345<br>170M6346†<br>170M6347‡<br>170M6348‡<br>170M6349‡|170M6538<br>170M6539<br>170M6540<br>170M6541<br>170M6542<br>170M6543<br>170M6544<br>170M6545<br>170M6546<br>170M6547†<br>170M6548†<br>170M6549‡|170M6494<br>170M6495<br>170M6496¥<br>170M6497¥<br>170M6498¥<br>170M6499¥<br>170M6500<br>170M6501|170M6588<br>170M6589<br>170M6590<br>170M6591<br>170M6592<br>170M6593<br>170M6594<br>170M6595<br>170M6596†<br>170M6597‡<br>170M6598‡<br>170M6599‡|170M6644<br>170M6645<br>170M6646¥<br>170M6647¥<br>170M6648¥<br>170M6649¥<br>170M6650<br>170M6651|3|315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>900<br>1000<br>1100<br>1250†<br>1400†|9500<br>13500<br>19500<br>31000<br>39000<br>55000<br>83500<br>115000<br>205000<br>305000<br>450000<br>575000<br>810000<br>1250000|58000<br>81500<br>120000<br>185000<br>235000<br>325000<br>495000<br>705000<br>995000<br>1500000<br>2150000<br>2800000<br>3950000<br>6000000|77500<br>110000<br>160000<br>245000<br>310000<br>435000<br>665000<br>940000<br>1300000<br>1900000<br>2750000<br>3600000|85<br>90<br>95<br>100<br>105<br>110<br>115<br>120<br>125<br>130<br>135<br>140<br>145<br>150|
†Rated voltage (IEC) 1100V.
‡Rated voltage (IEC) 1000V.
¥Rated voltage (IEC) 1250V.
- Watts loss provided at rated current.
- Microswitch indicator ordered separately. See accessories on pages 212-213.
- For fuse curves see pages 193 and 194.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**190**
**High Speed Fuses**
## **Square Body US Style — 1250V/1300V (IEC/UL): 50-1400A**
## **1250V/1300V (IEC/UL) 50-1400A**
## **Specifications**
**Description:** Square body US style high speed fuses. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 1250Vac (IEC)
— 1300Vac (UL)
Amps: — 50-1400A
IR: — 100kA RMS Sym. **Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2, CSA Certified: Class 53787, File 1422-30.
**==> picture [239 x 179] intentionally omitted <==**
**----- Start of picture text -----**<br>
Electrical 1.5<br>K<br>1.25 ee ee ee es<br>Characteristics<br>1.0<br>=SSa=<br>Total Clearing I [2] t eee ae ee<br>The total clearing I [2] t at 0.5 cr | | | TT |<br>rated voltage and at power 0.4 a<br>factor of 15% are given in 0.3 i ee<br>the electrical<br>characteristics. For other 0.2 asin<br>E<br>voltages, the clearing I [2] t is | | tT ft tt g<br>found by multiplying by 400 600 800 1000 1200 1400<br>Dashed lines (- - - - - -) apply to the<br>correction factor, K, given as following amperages:.<br>a function of applied working Size Amps.<br>1* 400A<br>voltage, Eg, (rms). 1 500-630A<br>2 630-1000A<br>3 800-1400A<br>**----- End of picture text -----**<br>
## **Arc Voltage**
**==> picture [239 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 3<br>2.5 UL<br>This curve gives the peak | |}eeeteet<br>1.8 ee eee<br>arc voltage, UL, which<br>may appear across the 1.4 L-r | [| ‘Cl |<br>fuse during its operation 10 [3] a | | d[ dT J<br>as a function of theapplied 8 a=———i=Pe ee ee eee<br>working voltage, Eg, (rms) 6<br>5<br>at a power factor of 15%. a<br>4<br>E<br>3 g<br>400 600 800 1000 1200 1400<br>Power Losses<br>1.0<br>Watts loss at rated current 0.8 Kp<br>area arena<br>SS<br>is given in the electrical 0.6<br>characteristics. The curve 0.5 r | | | [A | |<br>allows the calculation of 0.4 | [| | | hy ft<br>the power losses at load 0.3 PiT i] Yytl | fl<br>currents lower than the<br>rated current. The 0.2<br>HEE<br>correction factor, Kp, is 7 Z|<br>given as a function of the 0.1 Ib<br>VAnEEEE<br>RMS load current, Ib, in % 30 40 50 60 70 80 90 100%<br>of the rated current.<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See pages 153 (690V/700V) and 178 (1000V)
**Dimensions - mm** Type -FU/115, -FKE/115
**==> picture [237 x 158] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>6<br>FF<br><— A —><br>D C1<br>E C2<br>PS FAT<br>E I H<br>1 |) ° fer:<br>**----- End of picture text -----**<br>
**Size B C1 C2 D E H I** 1* 156 130 101 59 45 20 10 1 160 127 102 69 53 25 14 ~~a~~ 2 160 127 102 77 61 25 14 ~~a~~ 3 159 128 101 92 76 36 16 FF 1mm = 0.0394” / 1” = 25.4mm
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**191**
**High Speed Fuses**
## **Square Body US Style — 1250V/1300V (IEC/UL): 50-1400A**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|||||||
|---|---|---|---|---|---|---|---|
|**Catalog Numbers**||**Size**||**Electrical Characteristics**||||
|<br>**-FU/115**<br>**Without**<br>**Indicator**|<br>**-FKE/115**<br>**Type K**<br>**Indicator**<br>**for Micro**|||||||
||||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**|||**Watts**<br>**Loss**|
|||||**Pre-arc**|<br>**Clearing**<br>**at 1000V**|**Clearing**<br>**at 1250V**||
|170M3688<br>170M3689<br>170M3690<br>170M3691<br>170M3692<br>170M3693<br>170M3694<br>170M3695<br>170M3696<br>170M3697|170M3738<br>170M3739<br>170M3740<br>170M3741<br>170M3742<br>170M3743<br>170M3744<br>170M3745<br>170M3746<br>170M3747|1*|50<br>63<br>80<br>100<br>125<br>160<br>200<br>250<br>315<br>350|135<br>215<br>420<br>750<br>1450<br>2600<br>5150<br>9200<br>18500<br>27000|815<br>1300<br>2500<br>4450<br>9000<br>16000<br>31000<br>54500<br>115000<br>165000|1100<br>1750<br>3350<br>5950<br>11500<br>21000<br>41000<br>73000<br>150000<br>220000|15<br>20<br>25<br>30<br>35<br>40<br>45<br>55<br>60<br>65|
|170M4688<br>170M4689<br>170M4690<br>170M4691<br>170M4692<br>170M4693<br>170M4694<br>170M4695<br>170M4696<br>170M4697|170M4738<br>170M4739<br>170M4740<br>170M4741<br>170M4742<br>170M4743<br>170M4744<br>170M4745<br>170M4746<br>170M4747|1|160<br>200<br>250<br>315<br>350<br>400<br>450<br>500†<br>550†<br>630‡|1900<br>3800<br>7750<br>15000<br>20000<br>29500<br>42000<br>69500<br>95000<br>130000|11500<br>22500<br>46000<br>90000<br>125000<br>175000<br>250000<br>340000<br>465000<br>660000|15500<br>30000<br>61500<br>120000<br>165000<br>235000<br>335000|45<br>50<br>60<br>65<br>70<br>75<br>80<br>85<br>95<br>100|
|170M5688<br>170M5689<br>170M5690<br>170M5691<br>170M5692<br>170M5693<br>170M5694<br>170M5695<br>170M5696<br>170M5697<br>170M5698<br>170M5699<br>170M5700|170M5738<br>170M5739<br>170M5740<br>170M5741<br>170M5742<br>170M5743<br>170M5744<br>170M5745<br>170M5746<br>170M5747<br>170M5748<br>170M5749<br>170M5750|2|250<br>280<br>315<br>350<br>400<br>450<br>500<br>550<br>630<br>700†<br>800†<br>900‡<br>1000‡|6500<br>9350<br>13000<br>16500<br>23000<br>34000<br>48000<br>62000<br>115000<br>160000<br>245000<br>360000<br>480000|38500<br>55500<br>77500<br>97500<br>140000<br>205000<br>285000<br>370000<br>575000<br>795000<br>1200000<br>1750000<br>2350000|51500<br>74500<br>105000<br>135000<br>180000<br>270000<br>380000<br>495000<br>730000|65<br>70<br>75<br>80<br>85<br>90<br>95<br>100<br>110<br>115<br>120<br>125<br>135|
|170M6688<br>170M6689<br>170M6690<br>170M6691<br>170M6692<br>170M6693<br>170M6694<br>170M6695<br>170M6696<br>170M6697<br>170M6698†<br>170M6699†<br>170M6700‡<br>170M6701‡|170M6738<br>170M6739<br>170M6740<br>170M6741<br>170M6742<br>170M6743<br>170M6744<br>170M6745<br>170M6746<br>170M6747<br>170M6748†<br>170M6749†<br>170M6750‡<br>170M6751‡|3|315<br>350<br>400<br>450<br>500<br>550<br>630<br>700<br>800<br>900<br>1000¥<br>1100¥<br>1250¥<br>1400¥|9500<br>13500<br>19500<br>31000<br>39000<br>55000<br>83500<br>115000<br>205000<br>305000<br>450000<br>575000<br>810000<br>1250000|58000<br>81500<br>120000<br>185000<br>235000<br>325000<br>495000<br>705000<br>995000<br>1500000<br>2150000<br>2800000<br>3950000<br>6000000|77500<br>110000<br>160000<br>245000<br>310000<br>435000<br>665000<br>940000<br>1300000<br>1900000|185<br>90<br>95<br>100<br>105<br>110<br>115<br>120<br>125<br>130<br>135<br>140<br>145<br>150|
- †Rated voltage (IEC) 1100.
- ‡Rated voltage (IEC) 1000V.
- ¥ UL Recognition at 1000V.
- Watts loss provided at rated current.
- Microswitch indicator ordered separately. See accessories on pages 212-213. • For fuse curves see pages 193 and 194.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**192**
**High Speed Fuses**
## **Square Body Size 1*, 1 — 1250V/1300V (IEC/UL): 50-1400A**
**Size 1* — 50-400A:1250V Time-Current Curve**
## **Size 1 — 160-630A: 1250V**
## **Time-Current Curve**
**==> picture [493 x 536] intentionally omitted <==**
**----- Start of picture text -----**<br>
10) =F SS 104 | | |<br>0 EAN Ep 103 a eS<br>poe eee a<br>eeNN ae EAT)0 OE DE<br>Semel VSN SeaSUNOS Safi nialoc Babt AvPegee<br>102<br>\ \ \ \\\\\ ly nn } tT A TTY IANA ; Tey A<br>10 [1 ]<br>eA WE AIA Ste<br>AAA WE EAA}<br> etSee ASEEL VA ——— 10 [0 ] PAM=e AMATee<br>oe eeFETon elaslele\ sl e \e\ls 0 Errnan |—— a a eee ce<br>meee sle\ele\ ele\é mmaaiill 10–1 a<br>ee OVE SE (8 [218 |S Sa FHEE<br>EA WM es Oe A<br>10 [–2 ]<br>. QUA ARRAY pot TE TET TTA AK ANAAAOAAND<br>10 [–3 ]<br>PERERA PEE NARA<br>WAQAAY \ \ N<br>RRR NSS<br>10"10° EEA10° 10° 10° 1x10 [–4 ] 1x10 PE 2 103 ANAS 104 CTT 105<br>Prospective Current In Amp RMS<br>Prospective Current in Amp r.m.s.<br>Peak Let-Through Curve Peak Let-Through Curve<br>10 [5] 10 [5]<br>B B<br>400A 630A500A [550A]<br>ptee PP AA ee 350A315A250A200A CnAA ee | 400A315A250A — [450A][350A]<br>een ae pat ee Cl 160A125A esA Y (LeercS 5 200A160A<br>10 [4] 100A80A 10 [4]<br>63A<br>50A<br>1 a2ees Ln AR Sateth<br>103 | [|] | | ieeee TT Till UINNeeLI | UI| 10 [3] |a| AE AT | TEa lll<br>AIH A EE EE LZ A<br>2x102 1x10 Viti [2] 10Prospective Short-Circuit Current Symmetrical RMS [3] FT PT 10 [4] TEE 10 [5] 10 [6] 2x10 [2] 1x10 Ye 2 10Prospective Short-Circuit Current Symmetrical RMS3 104 105 106<br>630A fuse is derated to 1100V (IEC).<br>00A 550A<br>160A 200A 250A 315A 350A 400A 450A 5 630A<br>Virtual Pre-Arcing Time In Seconds<br>Peak Let-Through In Amperes<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
## **Data Sheet: 17056632**
**Data Sheet: 17056630**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**193**
**High Speed Fuses**
## **Square Body Size 2, 3 — 1250V/1300V (IEC/UL): 50-1400A**
## **Size 2 — 250-1000A: 1250V**
## **Time-Current Curve**
**Size 3 — 315-1400A: 1250V Time-Current Curve**
**==> picture [230 x 318] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4 ] FA<br>LO hp<br>10 [3 ]<br>pT | ETE ETT<br>ATRL<br>10 [2 ] PeESEEee<br>ee ee ed A SA id<br>EO<br>\ \ A<br>10 [1 ]<br>PAA<br>10 [0 ] SSS SSS Sete n ee tee as 2 — eee<br>eeeeeeree SE ELC ARLE TE a 8 Seen meen<br>a A<br>10 [–1 ]<br>a<br>10–2<br>ECHRN ANGDANS\<br>10 [–3 ] RRA<br>TEAR RRA<br>1x10 [–4 ] 1x10 Sd 2 1 103 NSN 104 NNNUI 105<br>Prospective Current In Amp RMS<br>250A 280A 315A 350A 400A 450A 500A 550A 630A 700A 800A 900A 1000A<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
## **Peak Let-Through Curve**
**==> picture [251 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [5] B 1000A800A 900A<br>eePOPHaAeEERE EF i 630A500400A315A250A — A 700A550A450A350A280A<br>ane C err ee = —<br>104<br>a a et<br>Lt Ze<br>a) a |<br>103 ap+} PA tt ff|<br>A<br>ay<br>LZ<br>2x102 1x10 VT 2 103 TT] 104 105 106<br>Prospective Short-Circuit Current Symmetrical RMS<br>900-1000A fuses are derated to 1100V (IEC).<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**==> picture [125 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
1250-1400A fuses are derated to 1100V (IEC).<br>**----- End of picture text -----**<br>
## **Data Sheet: 17056636**
**Data Sheet: 17056634**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**194**
**High Speed Fuses**
## **Square Body Flush End Contact Size 4 — 1250V (IEC): 1400-2500A**
## **1250V (IEC) 1400-2500A**
## **Specifications**
**Description:** High speed square body fuses, for the protection of the power rectifier section of the equipment. **Dimensions:** See dimensions illustration.
**Ratings:**
Volts: — 1250Vac (IEC) Amps: — 1400-2500A IR: — 125kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized E125085.JFHR2.
## **Electrical Characteristics**
## **Total clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Arc Voltage**
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied , working voltage Eg (rms) at a power factor of 15%.
## **Power Losses**
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See pages 163 (690V/700V) and 182 (1000V)
## **Catalog Numbers**
|**Fuse**<br>**Size**|**Catalog Number**|**Catalog Number**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|---|---|
||**-BKN/105**<br>**Type K**<br>**Indicator**|**-SBKN/105**<br>**Type K**<br>**Indicator**|**Rated**<br>**Voltage**<br>**(V)**|**Rated**<br>**Current**<br>**RMS-Amp**|**I**<br>**2t (A**<br>**2Sec)**||**Watt**<br>**Loss**<br>**(W)**|
||||||**t (A**<br><br>**Pre-arc**|**Sec)**<br>**Clearing**<br>**at 1250V**||
|4|170M7217<br>170M7597<br>170M7676<br>170M7532<br>170M7633<br>170M7592<br>170M7107<br>170M7595|170M7512<br>170M7510<br>170M7511<br>170M7976<br>170M7513<br>170M7546<br>170M7516<br>170M7978|1250|1400<br>1500<br>1700<br>1800<br>2000<br>2200<br>2400<br>2500|800000<br>1000000<br>1400000<br>1700000<br>2300000<br>3100000<br>4000000<br>4500000|5000000<br>6200000<br>8700000<br>11000000<br>14500000<br>19500000<br>25000000<br>28000000|195<br>200<br>220<br>225<br>235<br>245<br>255<br>260|
Data Sheet: 170K6640 , 170K6642
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**195**
**High Speed Fuses**
## **Square Body Flush End Contact Size 4 — 1250V (IEC): 1400-2500A**
## **Dimensions - mm**
Type 4BKN/ 105
**==> picture [16 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
106.6<br>**----- End of picture text -----**<br>
Type 4SBKN/ 105
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**196**
**High Speed Fuses**
## **Square Body Flush End Contact Size 4 — 1250V (IEC): 1400-2500A**
## **Size 4 — 1400-2400A: 1250V**
**Time-Current Curve**
## **Size 4 — 2300-2500A: 1250V Time-Current Curve**
**==> picture [125 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**==> picture [124 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**Peak Let-Through Curve**
**Peak Let-Through Curve**
**Data Sheet: Available upon request**
**==> picture [145 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data Sheet: Available upon request<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**197**
**High Speed Fuses**
## **Square Body Flush End Contact Size 23— 1250V (IEC/UL): 630-2800A**
## **1250V (IEC) 630-2800A**
## **Specifications**
**Description:** High speed square body fuses, for the protection of the power rectifier section of the equipment.
**Dimensions:** See dimensions illustration.
## **Ratings:**
## **Arc Voltage**
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied , working voltage Eg (rms) at a power factor of 15%.
Volts: — 1250Vac (IEC) Amps: — 630-2800A
IR: — 125kA RMS Sym.
**Agency Information:** CE, Designed and tested to IEC 60269: Part 4. UL Recognized.
## **Electrical**
## **Characteristics**
## **Total clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Power Losses**
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **For Other Voltage Ratings in This Body Style**
- See pages 165 (660V) and 185 (1000V)
## **Catalog Numbers**
|**Fuse**<br>**Size**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|---|---|---|---|---|---|
||**-BU/75**<br>**without**<br>**Indicator**|**-BKE/75**<br>**Type K**<br>**Indicator**|**-BKN/75**<br>**Type K**<br>**Indicator**|**-BU/80**<br>**without**<br>**Indicator**|**-BKE/80**<br>**Type K**<br>**Indicator**|**-BKN/80**<br>**Type K**<br>**Indicator**|**Rated**<br>**Voltage**<br>**(V)**|**Rated**<br>**Current**<br>**RMS-Amp**|**I**<br>**2t (A**<br>**2Sec)**||**Watts**<br>**Loss**<br>**(W)**|
||||||||||**t (A**<br><br>**Pre-arc**|**Sec)**<br>**Clearing at**<br>**1250V**||
|23|170M6775<br>170M6776<br>170M6777<br>170M6805<br>170M6778<br>170M6779<br>170M6780<br>170M6781<br>170M6782<br>170M6783|170M6795<br>170M6796<br>170M6797<br>170M6807<br>170M6798<br>170M6799<br>170M6800<br>170M6801<br>170M6802<br>170M6803|170M6785<br>170M6786<br>170M6787<br>170M6806<br>170M6788<br>170M6789<br>170M6790<br>170M6791<br>170M6792<br>170M6793|170M6784<br>170M6815|170M6804<br>170M6833|170M6794<br>170M6827|1250|630<br>700<br>800<br>900<br>1000<br>1100<br>1250<br>1400<br>1600<br>1800<br>2000<br>2200|38000<br>54000<br>78000<br>120000<br>155000<br>220000<br>330000<br>460000<br>820000<br>1200000<br>1800000<br>2300000|310000<br>440000<br>640000<br>980000<br>1250000<br>1750000<br>2700000<br>3800000<br>5200000<br>7600000<br>11000000<br>14500000|170<br>180<br>190<br>200<br>210<br>220<br>230<br>240<br>250<br>260<br>270<br>280|
|||||170M6816<br>170M6817|170M6834<br>170M6835|170M6828<br>170M6829|1100|2500<br>2800|3200000<br>5000000|†16000000<br>†24000000|290<br>300|
† A[2] s @ 1000V Data Sheet: 170K6638
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**198**
**High Speed Fuses**
## **Square Body Flush End Contact Size 23— 1250V (IEC/UL): 630-2800A**
## **Dimensions - mm**
## **Size 23 — 630-2800A: 1250V Time-Current Curve**
**==> picture [124 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**199**
**High Speed Fuses**
## **Square Body Flush End Contact Size 5— 1000V-2000V: 1800-5000A**
## **1000V (IEC) 1800-5000A**
## **Specifications**
**Description:** High speed square body fuses, for the protection or isolation for components such as diodes, silicon controlled rectifiers (SCRs), Gate torn-Off Thyristors (GTOs) and IGBTs. **Dimensions:** See dimensions illustration.
**Ratings:**
Volts: — 1000-2000Vac (IEC) Amps: — 1800-5000A
IR: — 300kA RMS Sym. estimated, 197kA tested **Agency Information:** Consult Bussmann. bulehighspeedtechnical@cooperindustries.com
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- AC and DC drives
- High power converters/rectifiers
## **Dimensions - mm (in)**
This dimension drawing is an example of the range of size 5 fuses available.
**Contact Bussmann for available parts and technical information.**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**200**
**High Speed Fuses**
## **Square Body DC Fuses — 750Vdc: 63-500A**
## **750Vdc 63-500A**
## **Specifications**
**Description:** High speed fuses, for the protection of DC circuits in equipment. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 750Vdc
Amps: — 63-500A
IR: — 750Vdc IR: 100kA, L/R = 100 ms.
- 1000Vdc IR: 100kA, L/R = 40 ms
**Agency Information:** Consult Cooper Bussmann.
## **Electrical Characteristics**
## **Arc Voltage**
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg.
## **Power Losses**
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC common bus
- DC drives
- Power converters/rectifiers
- Reduced voltage starters
## **Catalog Numbers**
|**Fuse**<br>**Size**|**Catalog Numbers**|**Catalog Numbers**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|
||**-BK/130**|**-EK/-**|**Rated**<br>**Voltage**<br>**(Vdc)**|**Rated**<br>**Current**<br>**RMS-Amp**|**Watt**<br>**Loss**<br>**(W)**|
|1*|170E3577<br>170E3578<br>170E3579<br>170E3580<br>170E3581|170E3583<br>170E3584<br>170E3585<br>170E3586<br>170E3587|750|63<br>80<br>100<br>125<br>160|10.0<br>13.0<br>16.0<br>21.0<br>26.0|
|1|170E5417<br>170E5418|170E5420<br>170E5421||200<br>250|37.0<br>46.0|
|2|170E8335<br>170E8336<br>170E8337|170E8345<br>170E8346<br>170E8347||250<br>315<br>400|47.0<br>57.0<br>73.0|
|3|170E9681|170E9685||500|91.0|
Data Sheet: Size 1*: 170K3620 Size 1: 170K3622 Size 2: 170K3624 Size 3: 170K3626 Microswitch: 170H0069, 170H3027 (gold)
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**201**
**High Speed Fuses**
## **Square Body DC Fuses — 750Vdc: 63-500A**
## **Dimensions - mm**
Type –BK/ 130
|**Size/Type**<br>**A**<br>**B**<br>**D**|
|---|
|1*BK/130<br>129<br>43<br>61|
|1 BK/130<br>130<br>51<br>69<br>2 BK/130<br>130<br>59<br>77<br>3 BK/130<br>131<br>74<br>90<br>~~|~~<br>~~I~~<br>~~a~~<br>~~q~~<br>~~]~~<br>ses<br>@Iy|
Type –EK/ -
**==> picture [467 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
| — Size/Type A B C D E F G H I J<br>Oo ae 1* EK/155 124 156 129 180 43 36 41 9 9 18<br>J 1 EK/165 124 166 129 191 51 37 41 11 14 25<br>2 EK/170 124 170 129 205 59 42 48 13 21 30<br>ca 3 EK/170 125 170 130 206 74 51 56 13 20 36<br>**----- End of picture text -----**<br>
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**202**
## **High Speed Fuses** Bussmannby EzT-N ~~OO~~ eeeeeeeeee—CSC“‘“=#A **Square Body DC Fuses — 750Vdc: 63-500A Square Body DC Fuse — 63-160A: 750V Square Body DC Fuse — 200-250A: 750V Time-Current Curve Time-Current Curve**
**==> picture [125 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**==> picture [124 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**Peak Let-Through Curve**
## **Peak Let-Through Curve**
**Data Sheet: Available upon request**
**Data Sheet: Available upon request**
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**203**
**High Speed Fuses**
## **Square Body DC Fuses — 750Vdc: 63-500A**
## **Square Body DC Fuse — 250-400A: 750V**
## **Time-Current Curve**
## **Square Body DC Fuse — 500A: 750V Time-Current Curve**
**==> picture [124 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**==> picture [125 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**Peak Let-Through Curve**
## **Peak Let-Through Curve**
**==> picture [145 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data Sheet: Available upon request<br>**----- End of picture text -----**<br>
**Data Sheet: Available upon request**
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**204**
**High Speed Fuses**
## **Square Body DC Fuses — 1200Vdc: 160-420A**
## **1200Vdc 160-420A**
## **Specifications**
**Description:** High speed fuses that provide superior protection in light and heavy harsh DC traction applications as 1200Vdc and below circuits, and as DC link/power converters. **Dimensions:** See dimensions illustration. **Ratings:**
Volts: — 1200Vdc Amps: — 160-420A
## **Power Losses**
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
IR: — 1200Vdc = 100kA L/R: 15 ms.
**Agency Information:** Consult Cooper Bussmann.
## **Electrical**
## **Characteristics**
## **Arc Voltage**
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg.
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **Catalog Numbers**
|**Fuse**<br>**Type**|**Cat.Numbers**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|---|
||**-SKNB/140**<br>**Type K**<br>**Indicator**|**Rated**<br>**Voltage**<br>**(Vdc)**|**Rated**<br>**Current**<br>**RMS-Amp**|**Max I2t (A2Sec) @ 1000Vdc**||**Watts**<br>**Loss**<br>**(W)**|
|||||**L/R = 15ms**|**L/R = 45ms**||
|2SKN / 140|170F8230<br>170F8231<br>170F8232<br>170F8233<br>170F8234<br>170F8235|1200|160<br>200<br>250<br>315<br>400<br>420|12000<br>20000<br>43000<br>87000<br>180000<br>215000|20000<br>35000<br>75000<br>150000<br>310000<br>375000|75.0<br>85.0<br>94.0<br>104.0<br>120.0<br>122.0|
Data Sheet: 170K5520 Microswitch: 170H0069, 170H3027 (gold)
## **Dimensions - mm**
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**205**
**High Speed Fuses**
## **Square Body DC Fuses — 1200Vdc: 160-420A**
## **Square Body DC Fuse — 160-420A: 1200V Time-Current Curve**
**==> picture [124 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**Data Sheet: Available upon request**
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**206**
**High Speed Fuses**
## **Square Body DC fuses — 2000Vdc: 10-125A**
## **2000Vdc 10-125A**
## **Specifications**
**Description:** High speed fuses for the protection of DC circuits in equipment. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 1200Vdc
Amps: — 160-420A
IR: — 1200Vdc = 100kA L/R: 15 ms.
**Agency Information:** Consult Bussmann.
## **Power Losses**
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The
correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
## **Features and Benefits**
## **Electrical**
## **Characteristics**
## **Arc Voltage**
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg.
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **Catalog Numbers**
|**Fuse**<br>**Type**|**Cat. Number**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**||**Fuse**<br>**Type**|**Cat. Number**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|---|---|---|---|---|
||**-SKN/246**<br>**Type K**<br>**Indicator**|**Rated**<br>**Voltage**<br>**(Vdc)**|**Rated**<br>**Current**<br>**RMS-Amp**|**Watt**<br>**Loss**<br>**(W)**|||**-SKN/246**<br>**Type K**<br>**Indicator**|**Rated**<br>**Voltage**<br>**(Vdc)**|**Rated**<br>**Current**<br>**RMS-Amp**|**Watt**<br>**Loss**<br>**(W)**|
|1*SKN/246|170E3976<br>170E3970<br>170E3950<br>170E3951<br>170E3952<br>170E3953<br>170E3954<br>170E3955<br>170E3956|2000|10<br>16<br>20<br>25<br>32<br>40<br>50<br>63<br>80|7<br>11<br>13<br>17<br>22<br>27<br>34<br>43<br>50||1*SKN/246|170E3937<br>170E3938<br>170E3939<br>170E3940<br>170E3941<br>170E3942<br>170E3943<br>170E3944<br>170E3945|2000|20<br>25<br>32<br>40<br>50<br>63<br>80<br>100<br>125|13<br>16<br>20<br>25<br>32<br>40<br>51<br>64<br>80|
## **Dimensions - mm**
Data Sheet: 170K4538 Microswitch: 170H0239, 170H3030 (gold)
Data Sheet: 170K4900 Microswitch: 170H0239, 170H3030 (gold)
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**207**
**High Speed Fuses**
## **Square Body DC fuses — 2000Vdc: 10-125A**
## **Square Body DC Fuses — 10-80A: 2000V Time-Current Curve**
## **Square Body DC Fuses — 20-125A: 2000V Time-Current Curve**
**==> picture [124 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**==> picture [124 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
## **Peak Let-Through Curve**
**Data Sheet: Available upon request**
**Data Sheet: Available upon request**
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**208**
**High Speed Fuses**
## **Square Body DC Fuses — 4000Vdc: 20-450A**
## **4000Vdc 20-450A**
## **Specifications**
**Description:** High speed fuses for the protection of DC circuits in equipment. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 4000Vdc Amps: — 20-450A IR: — 60kA L/R: 25 ms. **Agency Information:** Consult Bussmann.
## **Power Losses**
Watts loss at rated current is given in the electrical characOd teristics. The curve allows the calculation of the power loss0.30.2 es at load currents lower than 04 the rated current. The correction factor, Kp, is given 20 as a function of the RMS load current, Ib, in % of the rated current.
## **Features and Benefits**
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
## **Electrical**
## **Characteristics**
## **Arc Voltage**
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg.
- Low watts loss
- Superior cycling capability
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **Catalog Numbers**
|**Fuse**<br>**Type**|**Cat. Numbers**|**Cat. Numbers**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|
||**-SKN/394**<br>**Type K**<br>**Indicator**|**Rated**<br>**Voltage**<br>**(Vdc)**|**Rated**<br>**Current**<br>**RMS-Amp**|**Watts**<br>**Loss**<br>**(W)**|
|1*SKN/394|170E3914<br>170E3915<br>170E3916<br>170E3917<br>170E3918<br>170E3919<br>170E3984<br>170E3933<br>170E3922|4000|20<br>25<br>32<br>40<br>50<br>63<br>80<br>100<br>125|23<br>28<br>34<br>45<br>57<br>72<br>91<br>114<br>143|
|2 SKN/394|170E8882<br>170E8883<br>170E8884||160<br>200<br>250|182<br>228<br>285|
|2//2SKN/394|170E8885<br>170E8886<br>170E8887<br>170E8888||315<br>350<br>400<br>450|360<br>400<br>455<br>515|
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**209**
**High Speed Fuses**
## **DC Fuses — 4000Vdc: 20-450A**
## **Dimensions - mm**
Type 1* SKN/ 394
Type 2SKN/ 394
Type 2/ / SKN/ 394
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**210**
**High Speed Fuses**
## **Square Body DC Fuses — 4000Vdc: 20-450A**
## **Square Body DC Fuses — 20-125A: 2000V**
## **Time-Current Curve**
## **Square Body DC Fuses — 160-450A: 4000V Time-Current Curve**
**==> picture [125 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
**==> picture [125 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current in Amps RMS<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
## **Peak Let-Through Curve**
**Data Sheet: Available upon request**
**Data Sheet: Available upon request**
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**211**
**High Speed Fuses**
## **Square Body Fuse Accessories**
## **Indicator Systems**
Typower ZILOX fuses are available with three different indicator systems.
## **1. Visual Indicator**
The indicator situated in one cover plate is clearly visible as soon as the fuse has operated. The minimum voltage for operating the indicator is 20V.
## **2. Type T Indicator**
The indicator is situated on one cover plate with a cover plate tag to accommodate an auxiliary switch. The minimum voltage for operating the indicator is 20V. A special low voltage indicator (1.5V) is available on request.
## **3. Type K Indicator**
This indicator is situated on the fuse body. It is covered by an adapter for snap-on mounting of an auxiliary switch. The operating voltage of the indicator is 1.5V. As a matter of safety, the factory mounted adapter must not be removed from the fuse.
## **Microswitch**
The Typower ZILOX fuses with either type T indicator or type K indicator can be equipped with a microswitch for remote electrical indication of fuse operations. All microswitches have one normally open and one normally closed contact. Ratings are 2A, 250Vac.
||**6.3 x 0.8mm**|**2.8 x 0.5mm**|**Indicator**|
|---|---|---|---|
|**Microswitch**|**6.3 x 0.8mm**<br>**Lugs**|**2.8 x 0.5mm**<br>**Lugs**|**Indicator**<br>**Type**|
|170H0235|**Lugs**<br>X|**Lugs**|**Type**<br>T|
|170H0236|X||T|
|170H0237||X|T|
|170H0238||X|T|
|170H0069|X||K|
|**Size**|**DIN 43 653**<br>**Type T**|**Type K**|**DIN 43 620**<br>**Type T**|**Type K**|**French Style**<br>**Type T**|**Type K**|**Flush End**<br>**Type T**|**Type K**|**US Style**<br>**Type K**|
|---|---|---|---|---|---|---|---|---|---|
|000|**Type T**<br>170H0236|**Type K**|**Type T**<br>170H0236|**Type K**|**Type T**|**Type K**|**Type T**|**Type K**|**Type K**|
||170H0238||170H0238|||||||
|00|170H0235||||||170H0235|||
||170H0237||||||170H0237|||
|1*|170H0235|170H0069|170H0235||170H0236|170H0069||170H0069|170H0069|
||170H0237||170H0237||170H0238|||||
|1|170H0235|170H0069|||170H0236|170H0069||170H0069|170H0069|
||170H0237||||170H0238|||||
|2|170H0235|170H0069|170H0235||170H0236|170H0069||170H0069|170H0069|
||170H0237||170H0237||170H0238|||||
|3|170H0235|170H0069|170H0236||170H0236|170H0069||170H0069|170H0069|
||170H0237||170H0238||170H0238|||||
|4||||||||170H0069||
|23||||||||170H0069||
|24||||||||170H0069||
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**212**
**High Speed Fuses**
## **Square Body Fuse Accessories**
## **Fuse Bases (Blocks)**
## **DIN 43 653 Fuse Bases**
For the Typower ZILOX fuses according to DIN 43 653, the following fuse bases are available:
|**Catalog**<br>**Number**|**Max**<br>**Volts**|**Amp**<br>**Rating**|**Center**<br>**Distance**|
|---|---|---|---|
|170H3003|1000|**Rating**<br>630|80mm|
|170H3004|1000|1250|80mm|
|170H3005|1400|630|110mm|
|170H3006|1400|1250|110mm|
The fuse bases rated 1250A can also be used for the fuses with higher rated current if the maximum load current is derated according to the table below:
|**Fuse Amp**|**Max Amp Load**|**Max Amp Load**||
|---|---|---|---|
|**Rating**|**In Fuse Base**|||
|1400|1325|||
|1500|1400|||
|1600|1500|||
|1800|1650|||
|2000|1800|||
|**Fixed Center**|**Max**|**Max. Fuse**|**Fuse**|
|**Base Style**|**Volts**|**Amp Rating**|**Size**|
|170H1007|1000|400|00, 000|
|170H1013|660|200|0000,000|
UL Recognized to UL 512.
## **Universal Fuse Bases**
For the Typower ZILOX fuses according to DIN 43 653, French style and North American style, the following fuse bases are available:
|**Modular**|**Max**|**Max. Fuse**||
|---|---|---|---|
|**Modular**<br>**Base Style**|**Max**<br>**Volts**|**Max. Fuse**<br>**Amp Rating**|**Data Sheet**|
|**Base Style**<br>1BS101|600|**Amp Rating**<br>100|1206|
|1BS102|600|400|1207|
|1BS103|600|400|1208|
|1BS104|600|600|1209|
|BH-0xxx|700|200|1200|
|BH-1xxx|2500|400|1201|
|BH-2xxx|5000|400|1202|
|BH-3xxx|1250|700|1203|
Modular fuse bases are UL Recognized to UL 512 and meet the spacing requirements of UL 347. Contact your Bussmann sales representative for more complete ordering information.
## **DIN 43 620 Fuse Bases**
|**Size**|**Part Number**|
|---|---|
|000-00|SB00-D|
|1*, 1|SB1-D|
|2,3|SB2-D|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**213**
**High Speed Fuses**
## **British BS 88 Fuses**
## **Introduction**
|**British BS 88 Contents**<br>**Fuse**<br>**Volts**|**British BS 88 Contents**<br>**Amp**<br>**Range**|**Page**|
|---|---|---|
|240|6-900|215-217|
|690|6-710|218-221|
|**Accessories**|||
|Indicator System & Fuse Bases|stem & Fuse Bases|222|
## **General Information**
Designed and tested to:
- BS 88: Part 4
- IEC 269: Part 4
- UL Recognized
Bussmann offers the industry’s widest range of British style semiconductor fuses and accessories.
Bussmann British style products use innovative arc quenching techniques and high grade materials to provide:
- Minimal energy let-through (I[2] t)
|**British BS 88 Fuse Ranges**|**British BS 88 Fuse Ranges**|**British BS 88 Fuse Ranges**|
|---|---|---|
|**Amps**|**Vac**|**Vdc**|
|6-900|240|150|
|6-710|690|500|
- Excellent DC performance
- Good surge withstand profile
British style fuses are typically found in equipment manufactured in the United Kingdom or British Commonwealth countries. However, North American manufacturers have begun to specify British style fuses — particularly in UPS applications at 240V or less — to take advantage of their size, performance and cost benefits.
## **Voltage Rating**
All Bussmann British style fuses are tested to IEC 269: Part 4. This standard requires a test voltage which is 5% higher than the rated voltage. In North America, fuses are required to clear only their rated voltage.
## **Accessories**
Trip-indicator fuses are available for use in parallel with the main fuse. Indicator fuses can be attached to the associated fuselink, or mounted separately in panel-mounted fuseclips. In addition, a push-on adapter and microswitch attachment are available, to provide remote indication. Fuse blocks are also available for most applications.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**214**
**High Speed Fuses** |
## **British BS 88 — 240V: 6-900A**
**==> picture [521 x 258] intentionally omitted <==**
**----- Start of picture text -----**<br>
LCT, LET, LMT, LMMT Arc Voltage 750 UL<br>This curve gives the peak<br>Specifications<br>Description: stud-mount fuses.BS 88 style arc voltage, UL, whichmay appear across the 500 Ty 1)<br>fuse during its operation 2)<br>Dimensions: See dimensions<br>as a function of theapplied<br>illustrations.<br>working voltage, Eg, (rms) 250<br>Ratings: a eS at a power factor of 15%. pZan<br>Volts: — 240Vac/150Vdc<br>E<br>Amps: — 6-900A g<br>Power Losses 100 200 300<br>IR: — 200kA RMS Sym.<br>1) LCT<br>Agency Information: CE, Designed and tested to: BS 88 Watts loss at rated current 2) LET, LMT, LMMT<br>Part 4, IEC 269 Part 4, UL Recognized. All fuses above have is given in the electrical 1.0 Kp<br>been tested at 318Vac. Consult Bussmann for specific ULRecognition status. characteristics. The curveallows the calculation of 0.80.60.5 SSse=c2<br>the power losses at load<br>Electrical Characteristics currents lower than the 0.4<br>Total Clearing I [[2]] t 1.61.4 K rated current. The correc- 0.3<br>tion factor, Kp, is given as 0.2<br>The total clearing I [[2]] t at rated 1.2 a function of the RMS load<br>voltage and at power factor 1.0 current, Ib, in % of the<br>of 15% are given in the electrical characteristics. Forelectrical characteristics. For 0.8 =o- rated current. 0.1 30 EECEEE 40 50 60 70 80 90Ib100%<br>**----- End of picture text -----**<br>
**Total Clearing I[[2]] t** 1.41.61.4 K The total clearing I[[2]] t at rated 1.2 voltage and at power factor 1.0 0.8 =oof 15% are given in the electrical characteristics. Forelectrical characteristics. For other voltages, the clearing 0.6 1) I[2] t is found by multiplying by 0.4 SATS correction factor, K, given as 0.2 a function of applied working oe 2) Eg voltage, Eg, (rms). 50 100 150 200 250 1) LCT 2) LET, LMT, LMMT
## **Catalog Numbers**
## **Electrical Characteristics**
|**Catalog**<br>**Numbers**|**Type**|**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2** **Sec)**|**I2t (A2** **Sec)**|**I2t (A2** **Sec)**|**Watts**<br>**Loss**|
|---|---|---|---|---|---|---|
||||**Pre-arc**|**t (ASec)**<br>**Clearing**<br>**Clearing**|||
|||||**at 120V**|**at 240V**||
|6LCT<br>10LCT<br>12LCT<br>16LCT<br>20LCT|LCT|6<br>10<br>12<br>16<br>20|2<br>3.8<br>7<br>20<br>25|6<br>12<br>22<br>50<br>80|9<br>22<br>32<br>100<br>160|1.0<br>2.5<br>2.5<br>2.5<br>4.0|
|25LET<br>32LET<br>35LET<br>50LET<br>63LET<br>80LET<br>100LET<br>125LET<br>160LET<br>180LETa|LET|25<br>32<br>35<br>50<br>63<br>80<br>100<br>125<br>160<br>180|18<br>32<br>50<br>100<br>180<br>300<br>600<br>600<br>1100<br>1600|120<br>200<br>320<br>500<br>1100<br>1900<br>3800<br>3800<br>7000<br>12000|250<br>450<br>600<br>1400<br>2200<br>3800<br>7500<br>7500<br>16000<br>29000|4.0<br>5.0<br>5.0<br>7.0<br>9.0<br>10.0<br>10.0<br>16.0<br>20.0<br>21.0|
|160LMT<br>200LMT<br>250LMT<br>315LMT<br>355LMT<br>400LMT<br>450LMT|LMT|160<br>200<br>250<br>315<br>355<br>400<br>450|1100<br>1500<br>3200<br>6000<br>8000<br>14000<br>18000|7000<br>10000<br>20000<br>35000<br>50000<br>70000<br>100000|16000<br>20000<br>40000<br>75000<br>100000<br>160000<br>220000|17.0<br>28.0<br>28.0<br>35.0<br>35.0<br>40.0<br>42.0|
|400LMMT<br>500LMMT<br>630LMMT<br>710LMMT<br>800LMMT<br>900LMMT|LMMT|400<br>500<br>630<br>710<br>800<br>900|6000<br>14000<br>24000<br>32000<br>52000<br>75000|35000<br>80000<br>150000<br>200000<br>300000<br>400000|80000<br>170000<br>300000<br>460000<br>600000<br>800000|60.0<br>64.0<br>75.0<br>77.0<br>82.0<br>97.0|
## **Dimensions - mm**
Fig. 2: LET
Fig. 1: LCT
**==> picture [249 x 268] intentionally omitted <==**
**----- Start of picture text -----**<br>
7.1<br>4<br>5.5<br>26.2 41.8 56<br>28 38 47<br>9.7<br>12.7<br>6.4 17.7<br>8.4 19.1 Fig. 4: LMMT<br>8.7<br>Fig. 3: LMT 25.4<br>1mm = 0.0394” / 1” = 25.4mm c 25.4 on eh 31 59 84<br>31 59 84<br>13.5<br>13.5 10.3<br>ie 10.3<br>41 A ?<br>83<br>38.1<br>Indicator (Optional) 38<br>**----- End of picture text -----**<br>
- Watts loss provided at rated current.
- Note: 7LET, 10LET, 12LET and 16LET are available for replacement purposes on existing equipment.
- See accessories on page 222.
## **Features and Benefits**
## **Typical Applications**
- Excellent cycling capability
- DC Common bus
- Excellent DC performance
- AC and DC drives
- Low arc voltage and low energy let-through (I[2] t)
- Power converters/rectifiers
- Reduced voltage starters
**Data Sheet: 720004**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**215**
**High Speed Fuses**
## **British BS 88 — 240V: 6-900A**
## **LCT 6-20A: 240V**
## **Time-Current Curve**
**==> picture [220 x 300] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2 6LCT<br>10LCT<br>10 [2]<br>12LCT<br>6 16LCT<br>4<br>20LCT<br>2<br>10 [1]<br>6<br>4<br>2<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>2 4 6 8 10 [1] 2 4 6 8 10 [2] 2 4 6 8 103<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
**Data Sheet: 35785296**
## **LET 25-180A: 240V**
**Time-Current Curve**
**==> picture [253 x 316] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>10 [2]<br>6 80LET<br>4 100LET<br>125LET<br>2 160LET<br>10 [1] 180LETa<br>6<br>4<br>25LET<br>2 32LET<br>10 [0] 35LET<br>6 50LET<br>4 63LET<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4] 10 [1] 2 4 6 8 10 [2] 2 4 6 8 103<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
**Data Sheet: 35785293**
**Peak Let-Through Curve**
**==> picture [252 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>10 [5] 900LMMT<br>6 800LMMT710LMMT<br>4 630LMMT<br>450LMT<br>400 & 500LMMT<br>2 355LMT<br>315LMT<br>10 [4] 250LMT<br>180LET<br>6 200LMT<br>4 160LET & LMT125 & 100LET<br> 80LET<br>2<br>10 [3]<br>6<br>4<br>2 63LET50LET<br>35LET<br> 10 [2] 32LET<br>25LET<br>6 20LCT16LCT<br>4 12LCT<br>10LCT<br> 6LCT<br>2<br>SYMMETRICAL FAULT<br>FULLY ASYMMETRICAL FAULT<br> 10 [1]<br>10 [1] 2 4 6 10 [2] 2 4 6 10 [3] 2 4 6 10 [4] 2 4 6 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**216**
**High Speed Fuses**
## **British BS 88 — 240V: 6-900A**
## **LMT 160-450A: 240V**
## **Time-Current Curve**
**==> picture [252 x 336] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>160LMT<br>10 [2] 200LMT<br>6 250LMT<br>4 315LMT<br>2 355LMT<br>400LMT<br>10 [1] 450LMT<br>6<br>4<br>2<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>10 [2] 2 4 6 8 10 [3] 2 4 6 8 104<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
**Data Sheet: 35785294**
## **LMMT 400-900A: 240V**
## **Time-Current Curve**
**==> picture [253 x 340] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>400LMMT<br>10 [2] 500LMMT<br>6 630LMMT<br>4 710LMMT<br>2 800LMMT<br>900LMMT<br>10 [1]<br>6<br>4<br>2<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>10 [2] 2 4 6 8 10 [3] 2 4 6 8 104<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
**Data Sheet: 35785295**
## **Peak Let-Through Curve**
**==> picture [252 x 213] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>10 [5] 900LMMT<br>6 800LMMT710LMMT<br>4 630LMMT<br>450LMT<br>400 & 500LMMT<br>2 355LMT<br>315LMT<br>10 [4] 250LMT<br>180LET<br>6 200LMT<br>4 160LET & LMT125 & 100LET<br> 80LET<br>2<br>10 [3]<br>6<br>4<br>2 63LET50LET<br>35LET<br> 10 [2] 32LET<br>25LET<br>6 20LCT16LCT<br>4 12LCT<br>10LCT<br> 6LCT<br>2<br>SYMMETRICAL FAULT<br>FULLY ASYMMETRICAL FAULT<br> 10 [1]<br>10 [1] 2 4 6 10 [2] 2 4 6 10 [3] 2 4 6 10 [4] 2 4 6 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**217**
**High Speed Fuses**
## **British BS 88 — 690V: 6-710A**
## **CT, ET, FE, EET, FEE, FM, FMM, MT, MMT**
## **Specifications**
**Description:** BS 88 style stud-mount fuses.
**Dimensions:** See dimensions illustrations.
## **Ratings:**
Volts: — 690Vac/500Vdc Amps: — 6-710A
IR: — 200kA RMS Sym.
**Agency Information:** CE, Designed and tested to: BS 88 Part 4, IEC 269 Part 4, UL Recognized. MT and MMT — 350Vdc (IEC) rating. Consult Bussmann for UL Recognition status.
## **Electrical Characteristics**
**==> picture [122 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.6<br>K<br>1.4<br>1.2<br>1.00.8 | | | Lz |]<br>0.6 TEA<br>0.4 Eeceaml|<br>1)<br>2)<br>0.2 fa | | |<br>E<br>g<br>| | [| |[|<br>200 300 400 500 600 690<br>1) CT, ET, EET, FE, FEE, MT, MMT<br>2) FM, FMM<br>**----- End of picture text -----**<br>
## **Total Clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
## **Arc Voltage**
**==> picture [245 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
UL<br>This curve gives the 1500 | | ty<br>1)<br>peak arc voltage, UL,<br>which may appear<br>1000<br>across the fuse during its 2)<br>operation as a function<br>of the applied working 500<br>voltage, Eg, (rms) at a<br>power factor of 15%.<br>E<br>g<br>Power Losses ACIP 200 400 600 660<br>1) CT<br>Watts loss at rated 2) ET, FE, EET, FEE, FM, FMM<br>current is given in the 1.0<br>electrical characteristics. 0.8 Kp<br>The curve allows the 0.6<br>calculation of the power 0.5<br>losses at load currents 0.4<br>lower than the rated 0.3 HEE<br>current. The correction<br>0.2<br>factor, Kp, is given as a<br>function of the RMS load<br>current, Ib, in % of the 0.1 SACELLE Ib<br>rated current. 30 40 50 60 70 80 90 100%<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Excellent cycling capability
- Excellent DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **Dimensions - mm**
**==> picture [508 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fig. 1: CT Fig. 2: ET, FE Fig. 3: EET, FEE Fig. 4: FM, MT Fig. 5: FMM, MMT<br>8.7<br>7.1 25.4 25.4<br>4<br>5.5<br>rit 9 Be 48 63.5 77 46 70 94 gj 50 A 113 a 50 A 113<br>54.8 64.3 74.6<br>14<br>11.9<br>9.7 13.5 10.3<br>We 12.7 MB 31.8 ta ee<br>10.3<br>6.4 17.1 3 7<br>8.7 nC 8.7 er 19.1 era 19 © 7 t 41 8 Ee 83<br>yo 7G: CS °@! 3 8. 1 :<br>38<br>1mm = 0.0394” / 1” = 25.4mm Figs. 4 & 5 “A” Dimensions<br>Type “A”<br>FM 80-85mm<br>FMM 80-85mm<br>MT 85mm<br>MMT 85mm<br>**----- End of picture text -----**<br>
**Data Sheet: 720024**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**218**
**High Speed Fuses**
## **British BS 88 — 690V: 6-710A**
## **Catalog Numbers**
## **CT 6-20, ET 25-80A: 690V**
|||||**Electrical**|**Characteristics**|**Characteristics**||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||**Catalog**||**Rated**<br>**Current**||**I2t (A2 Sec)**<br>**Clearing**<br>**Clearing**||**Watts**|**Time-Current**||||||||||||||**Curve**||||||||||||||||||||||||||||||||||||||
||**Numbers**|**Type**|**RMS-Amps**|**Pre-arc**|**at 415V**|**at 660V**|**Loss**||104|||||||||||||||||||||||||||||||||||||||||||||||||||
||6CT||6|1.8|8.5|12|2||6|||||||||||||||||||||||||||||||||||||||||||||||||||
||10CT||10|7|30|48|3||4|||||||||||||||||||||||||||||||||||||||||||||||||||
||12CT|CT|12|10|40|65|3||2|||||||||||||||||||||||||||||||||||||||||||||||||||
||16CT<br>20CT||16<br>20|16<br>32|66<br>150|110<br>220|7<br>7||103<br>6|||||||||||||||||||||||||||||||||||||||||||||||||||
||25ET||25|25|150|250|7||4||||||||||||||||||||||||||||||||||||25ET|||||||||||||||
||32ET||32|32|190|350|11||2||||||||||||||||||||||||||||||||||||32ET|||||||||||||||
||35ET<br>40ET<br>45ET|ET|35<br>40<br>45|52<br>103<br>103|310<br>600<br>680|500<br>900<br>1100|11<br>9<br>11||6<br>4<br>102||||||||||||||||||||||||||||||||||||56ET<br>45ET<br>40ET<br>35ET|||||||||||||||
||56ET<br>63ET<br>80ET<br>35FE<br>40FE<br>45FE<br>50FE<br>63FE<br>71FE<br>80FE|FE|56<br>63<br>80<br>35<br>40<br>45<br>50<br>63<br>71<br>80|135<br>171<br>360<br>33<br>52<br>76<br>103<br>135<br>210<br>250|950<br>1200<br>2500<br>130<br>180<br>270<br>380<br>480<br>600<br>900|1500<br>2000<br>4000<br>200<br>300<br>450<br>600<br>750<br>950<br>1500|14<br>16<br>18<br>9<br>9<br>11<br>11<br>12<br>17<br>20|Virtual Pre-Arcing Time In Seconds|2<br>6<br>4<br>100<br>2<br>6<br>4<br>101<br>2|||||||||10CT<br>12CT<br>16CT<br>20CT<br>6CT|||||||||||||||||||||||||||80ET<br>63ET|||||||||||||||
||90FE||90|360|1300|2100|20|10–1||||||||||||||||||||||||||||||||||||||||||||||||||||
||100FE<br>90EET||100<br>90|470<br>490|1800<br>3000|2800<br>4500|23<br>19||4<br>6|||||||||||||||||||||||||||||||||||||||||||||||||||
||110EET<br>140EET|EET|110<br>140|600<br>1050|4000<br>7000|6500<br>12000|27<br>35|2<br>10–2||||||||||||||||||||||||||||||||||||||||||||||||||||
||160EET||160|1500|10000|17000|39||6|||||||||||||||||||||||||||||||||||||||||||||||||||
||100FEE<br>120FEE||100<br>120|400<br>540|1600<br>1900|2400<br>3100|24<br>32||4<br>2|||||||||||||||||||||||||||||||||||||||||||||||||||
||140FEE<br>160FEE|FEE|140<br>160|850<br>1000|2500<br>3700|3800<br>5700|36<br>46|6<br>10–3||||||||||||||||||||||||||||||||||||||||||||||||||||
||180FEE<br>200FEE||180<br>200|1400<br>1900|5300<br>7100|8400<br>11400|46<br>52||2<br>4|||||||||||||||||||||||||||||||||||||||||||||||||||
||180FM<br>200FM||180<br>200|1400<br>2600|7500<br>10500|13500<br>18500|40<br>40|10–4||2|||||4||||6|||8||101||||**2**|||||||4<br>6<br>8|||102|||||**2**|||||4||||6||8|||103|||
||225FM||225|3700|14500|26500|44||||||||||||||||||||Prospective Current In Amps RMS|||||||||||||||||||||||||||||||||
||250FM|FM|250|5200|20500|37500|48|||||||||||||||||||||||||||||||||||||||||||||||||||||
||280FM||280|7000|30500|55000|48|||||||||||||||||||||||||||||||||||||||||||||||||||||
||315FM||315|10000|40000|77000|55|||||||||||||||||||||||||||||||||||||||||||||||||||||
||350FM<br>400FMM<br>450FMM<br>500FMM<br>550FMM|FMM|350<br>400<br>450<br>500<br>550|15000<br>10000<br>15000<br>20000<br>30000|60000<br>40000<br>60000<br>82000<br>120000|105000<br>72500<br>105000<br>150000<br>215000|55<br>85<br>90<br>100<br>100|4<br>6<br>**Peak**||||**Let-Through**|||||||||||||||**Curve**|||||||||710MMT<br>630MMT<br>560MMT||||||||||||||||||||||||
||630FMM||630|45000|180000|310000|100||2|||||||||||||||||||||||||||500MMT<br>450MMT||||||||||||||||||||||||
||700FMM<br>160MT<br>180MT||700<br>160<br>180|60000<br>2400<br>3800|245000<br>15000<br>25000|420000<br>25000<br>38000|120<br>26<br>26||6<br>105|||||||||||||||||||||315MT 355MT 400MMT<br>280MT 355MMT<br>250MT 315MMT<br>280MMT<br>200MT<br>180MT 225MMT||||||||||||||||||||||||||||||
||200MT||200|6000|40000|58000|27||4||||||||||||||||||||||||||160MT 200MMT<br>180MMT|||||||||||||||||||||||||
||250MT<br>280MT<br>315MT<br>355MT<br>180MMT<br>200MMT<br>225MMT<br>280MMT<br>315MMT<br>355MMT<br>400MMT<br>450MMT|MT<br>MMT|250<br>280<br>315<br>355<br>180<br>200<br>225<br>280<br>315<br>355<br>400<br>450|11500<br>16500<br>19000<br>22000<br>1650<br>2200<br>3700<br>6600<br>8600<br>13500<br>21000<br>30000|80000<br>100000<br>125000<br>160000<br>12000<br>16000<br>26000<br>47000<br>62000<br>97000<br>150000<br>220000|110000<br>150000<br>180000<br>200000<br>18000<br>23000<br>40000<br>70000<br>91000<br>140000<br>220000<br>320000|32<br>35<br>42<br>51<br>42<br>42<br>42<br>47<br>51<br>54<br>60<br>57|Peak Let-Through Current|2<br>6<br>4<br>2<br>6<br>4<br>2<br>103<br>104||||||||||||||||||||||||||||||||||80ET<br>63ET<br>56ET|||||||||160EET<br>140EET<br>110EET<br>90EET||||||||
||500MMT<br>560MMT<br>630MMT<br>710MMT||500<br>560<br>630<br>710|42000<br>60000<br>68500<br>78000|300000<br>430000<br>500000<br>600000|450000<br>640000<br>720000<br>850000|64<br>64<br>86<br>105||4<br>6<br>102||||||||||||||||||||||||||20CT<br>16CT<br>12CT<br>10CT<br>6CT||||||||45ET<br>40ET<br>35ET<br>32ET<br>25ET|||||||||||||||||
|•|Watts loss provided at rated current.||||||||2|||||||||||||||||||||||||||||||||||||||||||||||||||
|•<br>•|Note: FC, 8ET, 12ET, 15ET, 20ET, 65EET and 75EET are available for replacement<br>purposes on existing equipment.<br>See accessories on page 222.||||||||101<br>101|||2||||4||6|||102||||2||4|||6||||103||2<br>4|6|||||104||2|||4|6|||105||||2|||||
||||||||||||||||||||||||Prospective Short-Circuit Current Symmetrical||||||||||||||||||||RMS|||||||||||||||||
**Data Sheet: 35785312**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**219**
**High Speed Fuses**
## **British BS 88 — 690V: 6-710A**
## **EET 90-160A, MT 160-355A: 690V**
**Time-Current Curve**
**==> picture [231 x 296] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6 160MT<br>4 180MT<br>200MT<br>2 250MT<br>10 [2] 280MT<br>315MT<br>6 355MT<br>4<br>2<br>10 [1]<br>6 90EET<br>4 110EET<br>140EET<br>2 160EET<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4] 2 4 6 8 10 [2] 2 4 6 8 10 [3] 2 4 6 8 104<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
**Data Sheet: 35785313**
## **MMT 180-710A: 690V**
## **Time-Current Curve**
**==> picture [253 x 336] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>400MMT<br>10 [3] 450MMT<br>6 500MMT<br>4 560MMT<br>630MMT<br>2 710MMT<br>10 [2]<br>6<br>4<br>2 180MMT<br>200MMT<br>10 [1] 225MMT<br>6 280MMT<br>4 315MMT<br>355MMT<br>2<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>10 [2] 2 4 6 8 10 [3] 2 4 6 8 104<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
**Data Sheet: 35785311**
**Peak Let-Through Curve**
**==> picture [253 x 221] intentionally omitted <==**
**----- Start of picture text -----**<br>
6<br>4 710MMT630MMT<br>560MMT<br>2 500MMT450MMT<br>315MT 355MT 400MMT<br>280MT 355MMT<br>10 [5] 250MT 315MMT<br>280MMT<br>6 180MT 225MMT 200MT<br>4 160MT 200MMT180MMT<br>2<br>10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>160EET<br>4 140EET<br>110EET<br>80ET 90EET<br>2 63ET<br>56ET<br>10 [2] 6 20CT16CT12CT10CT6CT 45ET40ET35ET32ET25ET<br>4<br>2<br>10 [1] 10 [1] 2 4 6 10 [2] 2 4 6 10 [3] 2 4 6 10 [4] 2 4 6 10 [5] 2<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**220**
**High Speed Fuses**
## **British BS 88 — 690V: 6-710A**
## **FE 35-100A & FM 180-350A: 690V FEE 100-200A & FMM 400-700A: 690V**
## **Time-Current Curve**
**==> picture [252 x 340] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>180FM<br>10 [2] 200FM<br>6 220FM<br>4 250FM<br>280FM<br>2 315FM<br>10 [1] 350FM<br>6<br>4<br>2<br>35FE<br>10 [0] 40FE<br>6 45FE<br>4 50FE<br>63FE<br>2 71FE<br>80FE<br>10 [–1] 90FE<br>6 100FE<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>2 4 6 8 10 [2] 2 4 6 8 10 [3] 2 4 6 8 104<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Time-Current Curve**
**==> picture [237 x 337] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>400FMM<br>10 [2] 450FMM<br>6 500FMM<br>4 550FMM<br>630FMM<br>2 700FMM<br>10 [1]<br>6 100FEE<br>4 120FEE<br>140FEE<br>2 160FEE<br>180FEE<br>10 [0] 200FEE<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>10 [2] 2 4 6 8 10 [3] 2 4 6 8 104<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
## **Peak Let-Through Curve**
**==> picture [500 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [5] 8 700FMM<br>6 6 630FMM550FMM<br>4 500FMM<br>4 450FMM<br>2 350FM 400FMM<br>315FM<br>10 [4] 6 280FM250FM225FM200FM 2<br>4 180FM<br>2 10 [4]<br>8<br>10 [3] 6<br>6<br>4 4<br>2<br>100FE<br>90FE 2<br>10 [2] 80FE<br>71FE<br>6 63FE50FE<br>4 45FE40FE 10 [3]<br>35FE 8 200FEE<br>2 180FEE<br>6 160FEE<br>10 [1] 140FEE<br>10 [1] 2 4 6 10 [2] 2 4 6 10 [3] 2 4 6 10 [4] 2 4 6 10 [5] 2 4 120FEE<br>Prospective Short-Circuit Current Symmetrical RMS 100FEE<br>2 10 [2] 2 4 6 10 [3] 2 4 6 10 [4] 2 4 6 10 [5] 2<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
## **Data Sheet: 35785292**
**Data Sheet: 35785314**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**221**
**High Speed Fuses**
## **British BS 88 Fuse Accessories**
## **Indicator System**
## **CL1 Panel Mount Clips**
**==> picture [493 x 366] intentionally omitted <==**
**----- Start of picture text -----**<br>
Trip-Indicators CL1 Panel mount fuse clips<br>are available for mounting a Ne, Ve<br>Trip-indicators are available for use in parallel with the trip-indicator when mounting<br>main fuse. They can either be attached to the associated directly on the fuse is<br>fuse or mounted separately in panel mounted fuse clips, impractical. Order part<br>reference CL1. A push-on adapter and microswitch number CL1.<br>attachment is available for use with the trip indicator to<br>give the facility of remote indication, reference MAI.<br>Fuse ratings of 20A and below cannot usually<br>Trip-Indicator<br>accommodate a trip-indicator.<br>Dimensions - mm<br>When a trip-indicator is to be attached to the main fuse an<br>accessory pack comprising a pair of mounting clips and an C6 21B E0.8 F 6.35<br>- = =r<br>appropriate trip indicator would be required. The clips are<br>snapped onto the fuse end caps and the indicator is<br>pressed into clips as shown.<br>es A D 6.8<br>Electrical Specifications<br>Ref. Dim. “A” (mm) RMS Volts<br>Type TI500 TI700 TI250 37.6 250<br>Maximum RMS Voltage 500 700 TI500 47.5 500<br>Maximum Peak Voltage 700 1000 TI600 55.7 600<br>Maximum DC Voltage 130 350 TI700 61.8 700<br>Cold Resistance (ohms) 0.3 0.45 TI1100 98.4 1100<br>Maximum permissible steady-state current 1.5A 1.5A TI1500 120.6 1500<br>Interrupting Capacity (RMS Symm.) 100,000 100,000 TI2000 147.5 2000<br>TI2500 198.3 2500<br>Pre-Arcing I [2] t 23 23<br>Total I [2] t (max volts) 46 46<br>CL1 Panel Mount Clip 6.0 8.7<br>Dimensions - mm<br>Fuse Indicator Kits<br>14<br>RMS For use<br>Kit. Ref. Details Volts with Fuse Ref.<br>EC-250 Fuse Mount 250 LET<br>MC250 Indicator Kits 250 LMT & LMMT 50.8<br>EC-600 (Includes one 660 FE, FEE & ET, FEE & ET FEE & ET<br>MC600 indicator 660 FM & FMM<br>B<br>—— |<br>**----- End of picture text -----**<br>
## **Trip-Indicators**
Trip-indicators are available for use in parallel with the main fuse. They can either be attached to the associated fuse or mounted separately in panel mounted fuse clips, reference CL1. A push-on adapter and microswitch attachment is available for use with the trip indicator to give the facility of remote indication, reference MAI.
Fuse ratings of 20A and below cannot usually accommodate a trip-indicator.
When a trip-indicator is to be attached to the main fuse an accessory pack comprising a pair of mounting clips and an appropriate trip indicator would be required. The clips are snapped onto the fuse end caps and the indicator is pressed into clips as shown.
## **Electrical Specifications**
**Fuse Indicator Kits**
**RMS For use Kit. Ref. Details Volts with Fuse Ref.** EC-250 Fuse Mount 250 LET MC250 Indicator Kits 250 LMT & LMMT EC-600 (Includes one 660 FE, FEE & ET, FEE & ET FEE & ET MC600 indicator 660 FM & FMM ~~=~~ MC700 and two clips) ~~——~~ 700 MT & MMT **Microswitch Adapter – MAI** We offer a microswitch, complete with adapter for securing the indicator. The microswitch is provided with double pole, single throw contacts, having both a normally open and a normally closed position. A special material has been employed in the construction of the adapter to provide reliable operation in the range of temperatures associated with standard operating conditions and during fuse operation.
## **Terminal Arrangement**
**==> picture [105 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
NO<br>NC<br>re<br>NC<br>Le NO<br>Dimensions in mm<br>**----- End of picture text -----**<br>
## **Microswitch and Adapter Type MAI**
|**Current Rating:**<br>AC 50/60Hz resistive load @ 250V RMS<br>AC 50/60Hz resistive load @ 127V RMS|4A<br>6A|
|---|---|
|DC, resistive load @ 110Vdc<br>DC,resistive load @ 30Vdc|0.7A DC<br>2A DC|
|**Maximum Working Voltage:**<br>Contact-to-contact (RMS)<br>Contact-to-contact(RMS)|1000V<br>1500V|
|**Maximum DC Volts:**|110Vdc|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**222**
**High Speed Fuses**
## **Ferrule Fuses**
## **Table of Contents**
|**Basic Catalog**||**Amp**||
|---|---|---|---|
|**Number**|**Volts**|**Range**|**Page**|
|FWA<br>FWX<br>FWH|150<br>250<br>500|5-60<br>1-50<br>0.25-30|224-225<br>226-227<br>228-231|
|FWC|600|6-32|232-233|
|FWP<br>FWK<br>FWJ|690V/700<br>750<br>1000|1-100<br>5-60<br>20-30|234-237<br>238-239<br>240-241|
|FWL/FWS|1250/1500/2000|2-30|242|
## **Accessories**
Fuse Holders
241
|**Ferrule Fuse Ranges**<br>**Volts**|**Ferrule Fuse Ranges**<br>**Amps**|**AC**|**DC**|
|---|---|---|---|
|150<br>250<br>500<br>600<br>700 (22 x 58mm)<br>700 (14 x 51mm)|5-60<br>1-50<br>0.25-30<br>6-32<br>20-100<br>1-50|X<br>X<br>X<br>X<br>X<br>X|X<br>X<br>X<br>X<br>—<br>X|
|750|5-60|X|X|
|1000|20-30|X|X (800Vdc)|
|1250<br>1500<br>2000|20-30<br>8-15<br>2-6|X<br>X<br>X|X (1000Vdc)<br>X (1000Vdc)<br>X (1000Vdc)|
## **General Information**
Bussmann offers a full line of ferrule style (cylindrical clip-mounted) fuses, designed and tested to meet standards and requirements in various locations around the world. Their unique design and construction provide:
- Superior cycling capability
- Low energy let-through (I[2] t)
Ferrule fuses provide an excellent solution for small UPS, small ac drives and other low power applications where space is at a premium.
## **Voltage Rating**
All Bussmann ferrule fuses — except 690V — have been tested at their rated voltage. The 690V ferrule fuse has been tested to the IEC 60269 standard, which requires clearing at the rated voltage +5%.
## **Accessories**
Ferrule fuses may be mounted in fuseclips, fuse holders, fuse blocks or fused switches. A variety of products are available. Please consult Bussmann Application Engineering to discuss your requirement.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**223**
**High Speed Fuses**
## **Ferrule — FWA 150V: 5-60A**
## **FWA 5-30A (10 x 38mm) 35-60A (21 X 51mm)**
## **Arc Voltage**
This curve gives the peak UL arc voltage, UL, which 300 may appear across the fuse during its operation as a function of theapplied 200 working voltage, Eg, (rms) at a power factor of 15%. 100 E g 50 100 150 **Power Losses** 1.0 Watts loss at rated current 0.8 Kp SeoSs== is given in the electricalcharacteristics. The curve 0.60.5 ee allows the calculation of 0.4 | tt | yt the power losses at load 0.3 PiT i] Yytl | ff currents lower than the rated current. The correction factor, Kp, is 0.2 _eeeen given as a function of the 0.1 — Ib RMS load current, Ib, in % 30 40 50 60 70 80 90 100% of the rated current.
## **Specifications**
**Description:** Ferrule style high speed fuses.
**Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 150Vac/dc Amps: — 5-60A IR: — 100kA Sym. **Agency Information:** CE, UL Recognition JFHR2.E91958
## **Electrical Characteristics**
|**Dimensions - in (mm)**<br>**Amp**<br>**Dimensions**<br>**Range**<br>**A**<br>**B**<br>**C**<br>5-30<br>1.5 (38.1)<br>0.375 (9.5)<br>0.406 (10.3)<br>35-60<br>2.0(50.8)<br>0.625(15.9)<br>0.811(20.6)<br>A<br>C<br>**Total Clearing I2t**<br>The total clearing I2t at<br>rated voltage and at power<br>factor of 15% are given in<br>the electrical<br>characteristics. For other<br>voltages, the clearing I2t is<br>found by multiplying by<br>correction factor, K, given<br>as a function of applied<br>working voltage, Eg, (rms).<br>150<br>102<br>70<br>22<br>1.5<br>1.0<br>0.5<br>0.3<br>0.2<br>0.15<br>Eg<br>K<br>1)<br>2)<br>1) 5-30A Range<br>2) 35-60A Range<br>ascneeen<br>KTITT Yi |<br>| ft<br>SEV4GRee<br>LALIT<br>tt<br>VTittt<br>|<br>et tt~~_ ~~<br>~~ime~~|**Dimensions - in (mm)**<br>**Amp**<br>**Dimensions**<br>**Range**<br>**A**<br>**B**<br>**C**<br>5-30<br>1.5 (38.1)<br>0.375 (9.5)<br>0.406 (10.3)<br>35-60<br>2.0(50.8)<br>0.625(15.9)<br>0.811(20.6)<br>A<br>C<br>**Total Clearing I2t**<br>The total clearing I2t at<br>rated voltage and at power<br>factor of 15% are given in<br>the electrical<br>characteristics. For other<br>voltages, the clearing I2t is<br>found by multiplying by<br>correction factor, K, given<br>as a function of applied<br>working voltage, Eg, (rms).<br>150<br>102<br>70<br>22<br>1.5<br>1.0<br>0.5<br>0.3<br>0.2<br>0.15<br>Eg<br>K<br>1)<br>2)<br>1) 5-30A Range<br>2) 35-60A Range<br>ascneeen<br>KTITT Yi |<br>| ft<br>SEV4GRee<br>LALIT<br>tt<br>VTittt<br>|<br>et tt~~_ ~~<br>~~ime~~|**Dimensions - in (mm)**<br>**Amp**<br>**Dimensions**<br>**Range**<br>**A**<br>**B**<br>**C**<br>5-30<br>1.5 (38.1)<br>0.375 (9.5)<br>0.406 (10.3)<br>35-60<br>2.0(50.8)<br>0.625(15.9)<br>0.811(20.6)<br>A<br>C<br>**Total Clearing I2t**<br>The total clearing I2t at<br>rated voltage and at power<br>factor of 15% are given in<br>the electrical<br>characteristics. For other<br>voltages, the clearing I2t is<br>found by multiplying by<br>correction factor, K, given<br>as a function of applied<br>working voltage, Eg, (rms).<br>150<br>102<br>70<br>22<br>1.5<br>1.0<br>0.5<br>0.3<br>0.2<br>0.15<br>Eg<br>K<br>1)<br>2)<br>1) 5-30A Range<br>2) 35-60A Range<br>ascneeen<br>KTITT Yi |<br>| ft<br>SEV4GRee<br>LALIT<br>tt<br>VTittt<br>|<br>et tt~~_ ~~<br>~~ime~~||currents lower than the<br>rated current. The correction factor, Kp, is<br>correction factor, Kp, is<br>given as a function of the<br>RMS load current, Ib, in %<br>of the rated current.<br>**Catalog Numbers**<br>**Electrical Characteristics**<br>**I2t (A2** **Sec)**<br>**Rated**<br>**Catalog**<br>**Current**<br>**Clearing**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Pre-arc**<br>**at 150V**<br>**Loss**<br>FWA-5A10F<br>5<br>1.6<br>8<br>1<br>FWA-10A10F<br>10<br>3.6<br>16<br>2.7<br>FWA-15A10F<br>10 x 38mm<br>15<br>14<br>55<br>3.3<br>FWA-20A10F<br>(13⁄32” x 11⁄2”)<br>20<br>33<br>130<br>3.8<br>FWA-25A10F<br>25<br>58<br>220<br>4.9<br>FWA-30A10F<br>30<br>100<br>400<br>4.9<br>FWA-35A21F<br>35<br>75<br>800<br>4.5<br>FWA-40A21F<br>21 x 51mm<br>40<br>100<br>1000<br>5.1<br>FWA-45A21F<br>(<br>13⁄16” x 2”)<br>45<br>130<br>1300<br>6<br>FWA-50A21F<br>50<br>170<br>1600<br>7.3<br>FWA-60A21F<br>60<br>250<br>2400<br>8.0<br>• Watts loss provided at rated current.<br>• See accessories on page 243.<br>**Features and Benefits**<br>• Excellent cycling capability and DC performance<br>• Low arc voltage and low energy let-through (I2t)<br>• Low watts loss in a compact size<br>0.2<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ibb<br>_eeeen<br>—<br> ~~manent~~|currents lower than the<br>rated current. The correction factor, Kp, is<br>correction factor, Kp, is<br>given as a function of the<br>RMS load current, Ib, in %<br>of the rated current.<br>**Catalog Numbers**<br>**Electrical Characteristics**<br>**I2t (A2** **Sec)**<br>**Rated**<br>**Catalog**<br>**Current**<br>**Clearing**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Pre-arc**<br>**at 150V**<br>**Loss**<br>FWA-5A10F<br>5<br>1.6<br>8<br>1<br>FWA-10A10F<br>10<br>3.6<br>16<br>2.7<br>FWA-15A10F<br>10 x 38mm<br>15<br>14<br>55<br>3.3<br>FWA-20A10F<br>(13⁄32” x 11⁄2”)<br>20<br>33<br>130<br>3.8<br>FWA-25A10F<br>25<br>58<br>220<br>4.9<br>FWA-30A10F<br>30<br>100<br>400<br>4.9<br>FWA-35A21F<br>35<br>75<br>800<br>4.5<br>FWA-40A21F<br>21 x 51mm<br>40<br>100<br>1000<br>5.1<br>FWA-45A21F<br>(<br>13⁄16” x 2”)<br>45<br>130<br>1300<br>6<br>FWA-50A21F<br>50<br>170<br>1600<br>7.3<br>FWA-60A21F<br>60<br>250<br>2400<br>8.0<br>• Watts loss provided at rated current.<br>• See accessories on page 243.<br>**Features and Benefits**<br>• Excellent cycling capability and DC performance<br>• Low arc voltage and low energy let-through (I2t)<br>• Low watts loss in a compact size<br>0.2<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ibb<br>_eeeen<br>—<br> ~~manent~~|currents lower than the<br>rated current. The correction factor, Kp, is<br>correction factor, Kp, is<br>given as a function of the<br>RMS load current, Ib, in %<br>of the rated current.<br>**Catalog Numbers**<br>**Electrical Characteristics**<br>**I2t (A2** **Sec)**<br>**Rated**<br>**Catalog**<br>**Current**<br>**Clearing**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Pre-arc**<br>**at 150V**<br>**Loss**<br>FWA-5A10F<br>5<br>1.6<br>8<br>1<br>FWA-10A10F<br>10<br>3.6<br>16<br>2.7<br>FWA-15A10F<br>10 x 38mm<br>15<br>14<br>55<br>3.3<br>FWA-20A10F<br>(13⁄32” x 11⁄2”)<br>20<br>33<br>130<br>3.8<br>FWA-25A10F<br>25<br>58<br>220<br>4.9<br>FWA-30A10F<br>30<br>100<br>400<br>4.9<br>FWA-35A21F<br>35<br>75<br>800<br>4.5<br>FWA-40A21F<br>21 x 51mm<br>40<br>100<br>1000<br>5.1<br>FWA-45A21F<br>(<br>13⁄16” x 2”)<br>45<br>130<br>1300<br>6<br>FWA-50A21F<br>50<br>170<br>1600<br>7.3<br>FWA-60A21F<br>60<br>250<br>2400<br>8.0<br>• Watts loss provided at rated current.<br>• See accessories on page 243.<br>**Features and Benefits**<br>• Excellent cycling capability and DC performance<br>• Low arc voltage and low energy let-through (I2t)<br>• Low watts loss in a compact size<br>0.2<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ibb<br>_eeeen<br>—<br> ~~manent~~|currents lower than the<br>rated current. The correction factor, Kp, is<br>correction factor, Kp, is<br>given as a function of the<br>RMS load current, Ib, in %<br>of the rated current.<br>**Catalog Numbers**<br>**Electrical Characteristics**<br>**I2t (A2** **Sec)**<br>**Rated**<br>**Catalog**<br>**Current**<br>**Clearing**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Pre-arc**<br>**at 150V**<br>**Loss**<br>FWA-5A10F<br>5<br>1.6<br>8<br>1<br>FWA-10A10F<br>10<br>3.6<br>16<br>2.7<br>FWA-15A10F<br>10 x 38mm<br>15<br>14<br>55<br>3.3<br>FWA-20A10F<br>(13⁄32” x 11⁄2”)<br>20<br>33<br>130<br>3.8<br>FWA-25A10F<br>25<br>58<br>220<br>4.9<br>FWA-30A10F<br>30<br>100<br>400<br>4.9<br>FWA-35A21F<br>35<br>75<br>800<br>4.5<br>FWA-40A21F<br>21 x 51mm<br>40<br>100<br>1000<br>5.1<br>FWA-45A21F<br>(<br>13⁄16” x 2”)<br>45<br>130<br>1300<br>6<br>FWA-50A21F<br>50<br>170<br>1600<br>7.3<br>FWA-60A21F<br>60<br>250<br>2400<br>8.0<br>• Watts loss provided at rated current.<br>• See accessories on page 243.<br>**Features and Benefits**<br>• Excellent cycling capability and DC performance<br>• Low arc voltage and low energy let-through (I2t)<br>• Low watts loss in a compact size<br>0.2<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ibb<br>_eeeen<br>—<br> ~~manent~~|
|---|---|---|---|---|---|---|---|
||B<br>~~Se~~|||• Used with finger-safe holders/blocks<br>**Typical Applications**||||
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
**Data Sheet: 720003**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**224**
**High Speed Fuses**
## **Ferrule — FWA 150V: 5-60A**
## **FWA 5-30A: 150V (10 x 38mm)**
## **Time-Current Curve**
## **FWA 35-60A: 150V (21 x 51mm)**
## **Time-Current Curve**
**==> picture [518 x 340] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4 ] 10 [4]<br>6 6<br>4 4<br>2 2<br>10 [3 ] 10 [3]<br>6 6<br>4 4<br>2 2<br>10 [2 ] 10 [2]<br>FWA-35A21F<br>6 6 FWA-40A21F<br>4 4 FWA-45A21F<br>2 2 FWA-50A21F<br>FWA-60A21F<br>10 [1 ] 10 [1]<br>6 FWA-5A10F 6<br>4 FWA-10A10F 4<br>FWA-15A10F<br>2 FWA-20A10F 2<br>FWA-25A10F<br>10 [0 ] FWA-30A10F 10 [0]<br>6 6<br>4 4<br>2 2<br>10 [–1 ] 10 [–1]<br>6 6<br>4 4<br>2 2<br>10 [–2 ] 10 [–2]<br>6 6<br>4 4<br>2 2<br>10 [–3 ] 10 [–3]<br>6 6<br>4 4<br>2 2<br>10 [–4 ] 10 [–4]<br>2 4 6 8 101 2 4 6 8 10 [2 ] 2 4 6 8 103 10 [1] 2 4 6 8 10 [2] 2 4 6 8 103<br>Prospective Current In Amps RMS Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
**Peak Let-Through Curve**
**==> picture [240 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>FWA-30A10F<br>2 FWA-25A10F<br>FWA-20A10F<br>10 [3] FWA-15A10F<br>6<br>4<br>2<br>FWA-12A10F<br>FWA-10A10F<br>10 [2] FWA-5A10F<br>6<br>4<br>2<br>10 [1]<br>2 4 6 2 4 6 2 4 6 2 4 6 2<br>10 [1] 10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Peak Let-Through Curve**
**==> picture [262 x 208] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>FWA-60A21F<br>6 FWA-50A21F<br>4 FWA-45A21F<br>FWA-40A21F<br>FWA-35A21F<br>2<br>10 [3]<br>6<br>4<br>2<br>10 [2]<br>6<br>4<br>2<br>10 [1]<br>2 4 6 2 4 6 2 4 6 2 4 6 2<br>10 [1] 10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
## **Data Sheet: 35785305**
**Data Sheet: 35785317**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**225**
**High Speed Fuses**
## **Ferrule — FWX 250V (UL): 1-50A**
## **FWX (14 x 51mm)**
## **Arc Voltage**
**==> picture [242 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 1.4<br>1.2 UL<br>This curve gives the 10 [3] CEE<br>peak arc voltage, UL,<br>800<br>which may appear ———<br>across the fuse during 600<br>its operation as a 500<br>function of the applied 400<br>1)<br>working voltage, Eg, 300 =ane<br>(rms) at a power factor 2)<br>of 15%. 200 Zan Eg<br>50 100 150 200 250<br>Power Losses<br>1.0<br>Watts loss at rated current 0.8 Kp<br>SSS2<br>is given in the electricalcharacteristics. The curve 0.60.5 soon<br>allows the calculation of 0.4 | | | | hy<br>the power losses at load 0.3 4<br>currents lower than the<br>rated current. The correction factor, Kp, is 0.2 LYtt<br>given as a function of the 0.1 Ib<br>osALE EEL<br>RMS load current, Ib, in % 30 40 50 60 70 80 90 100%<br>of the rated current.<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Ferrule style high speed fuses. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 250Vac/dc Amps: — 1-50A
IR: — 200kA RMS Sym.
— 50kA @ 250Vdc
**Agency Information:** CE, UL Recognition JFHR2.E91958 1-50A & CSA Component Acceptance file Class 1422-30, 1422-90 (53787) 5-30A
## **Electrical**
|**Electrical**|**Electrical**|**Electrical**|**Electrical**|the power losses at load<br>0.3<br>4|
|---|---|---|---|---|
|**Electrical**<br>**Characteristics**<br>**Total Clearing I2t**<br>The total clearing I2t at<br>rated voltage and at power<br>factor of 15% are given in<br>the electrical<br>characteristics. For other<br>voltages, the clearing I2t is<br>found by multiplying by<br>correction factor, K, given<br>as a function of applied<br>working voltage, Eg, (rms).<br>**Dimensions - mm (in)**<br>50.8<br>(2.000")<br>14.3<br>(0.563")<br>1.5<br>1.0<br>0.5<br>0.3<br>0.2<br>0.15<br>75<br>125<br>300<br>200<br>250<br>Eg<br>K<br>1)<br>2)<br>.__=---——==<br>BEEeeSSece<br>Sos> 7denne<br>[lLrae|<br>| | | tl<br>rhe tT<br>|<br>| Tt |<br>PELE<br>PTT tT<br>yt tT<br>PT TT TT yy ty~~_~~TH<br>~~— 4~~<br>~~fe~~||||the power losses at load<br>currents lower than the<br>rated current. The correction factor, Kp, is<br>correction factor, Kp, is<br>given as a function of the<br>RMS load current, Ib, in %<br>of the rated current.<br>**Catalog Numbers**<br>**Electrical Characteristics**<br>**Rated**<br>**I2t (A2Sec)**<br>**Catalog**<br>**Current**<br>**Clearing**<br>**Watts**<br>**Number**<br>**Size**<br>**RMS-Amps**<br>**Pre-arc**<br>**at 250V**<br>**Loss**<br>FWX-1A14F<br>1<br>—<br>—<br>—<br>FWX-2A14F<br>2<br>—<br>—<br>—<br>FWX-3A14F<br>3<br>—<br>—<br>—<br>FWX-4A14F<br>4<br>—<br>—<br>—<br>FWX-5A14F<br>14 x 51mm<br>5<br>1.6<br>13<br>1.3<br>FWX-10A14F<br>(9⁄16” x 2”)<br>10<br>3.6<br>24<br>3.4<br>FWX-15A14F<br>15<br>14<br>83<br>3.8<br>FWX-20A14F<br>20<br>33<br>200<br>4.6<br>FWX-25A14F<br>25<br>58<br>300<br>5.3<br>FWX-30A14F<br>30<br>100<br>500<br>5.9<br>FWX-50A14F<br>50<br>200<br>1800<br>5.7<br>• Watts loss provided at rated current.<br>• (250Vdc/Interrupting rating 50kA) UL Recognition & CSA Component Acceptance on 5<br>through 30A only. Consult Bussmann for additional ratings.<br>• See accessories on page 243.<br>0.3<br>0.2<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ibb<br>4<br>LYtt<br>tt<br>osALE EEL<br>ALE EELEEL<br>THT|
|||||**Features and Benefits**<br>• Excellent cycling capability and DC performance<br>• Low arc voltage and low energy let-through (I2t)|
||15.5<br>(0.610")<br>~~—~~|||• Low watts loss in a compact size<br>• Used with finger-safe holders/blocks|
## **Characteristics**
## **Total Clearing I[2] t**
## **Dimensions - mm (in)**
- Used with finger-safe holders/blocks
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
**Data Sheet: 720006**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**226**
**High Speed Fuses**
## **Ferrule — FWX 250V (UL): 1-50A**
## **FWX 1-30A: 250V (14 x 51mm)**
## **Time-Current Curve**
**==> picture [69 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current In Amps RMS<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [63 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
Prospective Current In Amps RMS<br>**----- End of picture text -----**<br>
**Data Sheet: 35785302**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**227**
**High Speed Fuses**
## **Ferrule — FWH 500V: 0.25-30A**
## **FWH (6 x 32mm)**
|**FWH (6 x 32mm)**|**FWH (6 x 32mm)**|**FWH (6 x 32mm)**|**FWH (6 x 32mm)**|
|---|---|---|---|
|**FWH (6 x 32mm)**<br>**Specifications**<br>**Description:** Ferrule style high<br>speed fuses.<br>**Dimensions:** See dimensions<br>illustrations.<br>**Ratings:**<br>Volts: — 500Vac (0.25-6.3A)<br>500Vdc (2-5A)<br>Amps: — 0.25-30A<br>IR: — 50kA at ≥ 20% pf (0.25-20A)<br>— 20kA at ≥ 20% pf (25-30A)<br>**Agency Information:** CE, UL Recognition JFHR2.E91958<br>0.25-30A, CSA Component Acceptance file Class 1422-30,<br>**Catalog Numbers**<br>**Electrical Characteristics**<br>**Rated**<br>**I2t (A2 Sec)**<br>**Catalog**<br>**Current**<br>**Clearing**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Pre-arc**<br>**at 500V**<br>**Loss**<br>FWH-.250A6F<br>0.25*<br>0.01<br>0.05<br>2.7<br>FWH-.500A6F<br>0.5*<br>0.05<br>0.25<br>1.2<br>FWH-001A6F<br>1*<br>0.4<br>2<br>1.7<br>FWH-002A6F<br>2*<br>1.3<br>3.5<br>3.2<br>FWH-3.15A6F<br>3.15*<br>3.1<br>7.7<br>2.9<br>FWH-005A6F<br>5*<br>15<br>40<br>2.1<br>FWH-6.30A6F 6 x 32mm<br>6.3*<br>36<br>90<br>2.3<br>FWH-007A6F<br>(<br>1⁄4” x 1<br>1⁄4”)<br>7*<br>50<br>125<br>2.5<br>FWH-010A6F<br>10**<br>9.9<br>139<br>2.86<br>FWH-12.5A6F<br>12.5**<br>20<br>60<br>3.53<br>FWH-015A6F<br>15**<br>44<br>146<br>3.08<br>FWH-016A6F<br>16**<br>48<br>177<br>4.48<br>FWH-020A6F<br>20**<br>75<br>259<br>4.26<br>FWH-025A6F<br>25**<br>126<br>345<br>—<br>FWH-030A6F<br>30**<br>145<br>430<br>—<br>*300% minimum opening current at rated voltage.<br>~~Tin~~||||
|1422-90 (53787) 0.25-7A<br>**Opening Times**|**200% minimum opening current at rated voltage.<br>• Consult Bussmann for DC ratings.<br>• See accessories on page 243.|||
|**Amp Ratings**<br>**150%**<br>**200%**<br>**300%**<br>0.25-7<br>> 30 min<br>< 30 min<br>≤ 10 sec|**Features and Benefits**|||
|10-30<br>< 30 min<br>< 30 min<br>≤ 10 sec|• Excellent cycling capability and DC performance|Excellent cycling capability and DC performance||
- Excellent cycling capability and DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss in a compact size
## **Dimensions - mm (inches)**
|31.8<br>(1.25")|||6.4<br>(0.25")|
|---|---|---|---|
|||||
|||||
||3.2|||
||(0.125")|||
- Used with finger-safe holders/blocks
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
**Data Sheet: 720038**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**228**
**High Speed Fuses**
## **Ferrule — FWH 500V: 0.25-30A**
## **FWH 0.25-7A: 500V (6 x 32mm)**
## **Time-Current Curve**
**==> picture [262 x 285] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4 FWH-002A6F<br>FWH-3.15A6F<br>2<br>FWH-005A6F<br>10 [3] FWH-6.30A6F<br>6 FWH-007A6F<br>4<br>2<br>10 [2]<br>6<br>4<br>2<br>10 [1]<br>6<br>4<br>2<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6 FWH-.250A6F<br>4 FWH-.500A6F<br>FWH-001A6F<br>2<br>10 [–2]<br>4x10 [–3]<br>.2 .4 .6 .8 10 [0] 2 4 6 8 10 [1] 2 4 6 8 10 [2] 2<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **FWH 10-30A: 500V (6 x 32mm) Time-Current Curve**
**==> picture [253 x 325] intentionally omitted <==**
**Data Sheet: 35785256**
**Data Sheet: 50955**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**229**
**High Speed Fuses**
## **Ferrule — FWH 500V: 1-30A**
## **FWH (14 x 51mm)**
## **Arc Voltage**
**==> picture [248 x 233] intentionally omitted <==**
**----- Start of picture text -----**<br>
Arc Voltage 2.0<br>1.6 SS UL<br>This curve gives the peakarc voltage, UL, which may 1.2 ee—<br>appear across the fuse 10 [3] a a ee<br>during its operation as a 800 eea ae<br>function of the applied 600 aa<br>working voltage, Eg, (rms) 500 | ot [|]<br>at a power factor of 15%. 400 [z|| |<br>Power Losses 300 Eg<br>100 200 300 400 500<br>Watts loss at rated current<br>1.0<br>is given in the electrical 0.8 ====—-= Kp<br>allows the calculation of thecharacteristics. The curve 0.60.5 er<br>power losses at load 0.4 | | | | hy Yt<br>currents lower than the 0.3 P| | Yi |<br>rated current. The correction 0.2 tA<br>tt<br>factor, Kp, is given as a<br>function of the RMS load ATI<br>current, Ib, in % of the rated 0.1 Ib<br>current. 30 ALLL 40 50 60 70 80 90 100%<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Ferrule style high speed fuses. **Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 500Vac Amps: — 1-30A IR: — 200kA RMS Sym. — 50kA @500Vdc
**Agency Information:** CE, UL Recognition 1- 30A & CSA Component Acceptance file Class 1422-30, (53787) on: 5 - 30A.
## **Electrical Characteristics**
|**Electrical Characteristics**|**Electrical Characteristics**|currents lower than the<br>rated current. The correction<br>factor, Kp, is given as a<br>0.3<br>0.2<br>P|<br>|<br>Yi |<br>tA<br>tt<br>ATI|currents lower than the<br>rated current. The correction<br>factor, Kp, is given as a<br>0.3<br>0.2<br>P|<br>|<br>Yi |<br>tA<br>tt<br>ATI|currents lower than the<br>rated current. The correction<br>factor, Kp, is given as a<br>0.3<br>0.2<br>P|<br>|<br>Yi |<br>tA<br>tt<br>ATI|currents lower than the<br>rated current. The correction<br>factor, Kp, is given as a<br>0.3<br>0.2<br>P|<br>|<br>Yi |<br>tA<br>tt<br>ATI|
|---|---|---|---|---|---|
|**Dimensions - mm (inches)**<br>**Total Clearing I2t**<br>The total clearing I2t at rated<br>voltage and at power factor<br>of 15% are given in the<br>electrical characteristics. For<br>other voltages, the clearing<br>t is found by multiplying by<br>correction factor, K, given as<br>a function of applied working<br>voltage, Eg, (rms).<br>500<br>400<br>250<br>100<br>1.5<br>1.0<br>0.5<br>0.3<br>0.2<br>0.15<br>Eg<br>K<br>§=========<br>lr |<br>|<br>| |<br>|<br>|<br>| |<br>Lt tt tt tt tt~~~ ~~<br>Lt Tt Tt tt TT<br>Lt tt tt Tt<br>| I<br>FTTETTT<br>Tt||factor, Kp, is given as a<br>function of the RMS load<br>current, Ib, in % of the rated<br>current.<br>**Catalog Numbers**<br>**Electrical Characteristics**<br>**Rated**<br>**I2t (A2 Sec)**<br>**Catalog**<br>**Current**<br>**Clearing**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Pre-arc**<br>**at 500V**<br>**Loss**<br>FWH-1A14F<br>14 x 51mm<br>1<br>—<br>—<br>—<br>FWH-2A14F<br>(9⁄16” x 2”)<br>2<br>—<br>—<br>—<br>FWH-3A14F<br>3<br>—<br>—<br>2.3<br>FWH-4A14F<br>4<br>—<br>—<br>—<br>FWH-5A14F<br>5<br>1.6<br>6.4<br>1.5<br>FWH-6A14F<br>6<br>1.6<br>6.4<br>1.5<br>FWH-10A14F<br>10<br>3.6<br>13<br>4<br>FWH-12A14F<br>12<br>—<br>—<br>—<br>FWH-15A14F<br>15<br>10<br>40<br>5.5<br>FWH-20A14F<br>20<br>26<br>96<br>6<br>FWH-25A14F<br>25<br>49<br>191<br>7<br>FWH-30A14F<br>30<br>58<br>232<br>9<br>• Watts loss provided at rated current.<br>• See accessories on page 243.<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ibb<br>ATI<br>ALLL<br> TET||||
|50.8<br>(2.000")<br>14.3<br>(0.563")<br>~~op~~ O||**Features and Benefits**<br>• Excellent cycling capability and dc performance<br>• Low arc voltage and low energy let-through (I2t)<br>• Low watts loss in a compact size<br>• Used with finger-safe holders/blocks||||
|15.5<br>(0.610")<br>~~S~~e~~e~~||**Typical Applications**||||
## **Total Clearing I[2] t**
The total clearing I[2] t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I[2] t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
**Dimensions - mm (inches)**
- DC common bus
- DC drives
- Power converters/rectifiers
- Reduced voltage starters
**Data Sheet: 720008**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**230**
**High Speed Fuses**
## **Ferrule — FWH 500V: 1-30A**
## **FWH 1-30A: 500V (14 x 51mm)**
## **Time-Current Curve**
**==> picture [298 x 374] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>10 [2]<br>FWH-5A14F<br>6<br>FWH-10A14F<br>4<br>FWH-15A14F<br>2 FWH-20A14F<br>FWH-25A14F<br>10 [1] FWH-30A14F<br>6<br>4<br>2<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>2 4 6 8 10 [1] 2 4 6 8 10 [2] 2 4 6 8 103<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [265 x 187] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>FWH-30A14F<br>FWH-25A14F<br>10 [3]<br>6<br>4<br>2<br>FWH-20A14F<br>FWH-15A14F<br>10 [2] FWH-10A14F<br>FWH-5A14F<br>6<br>4<br>2<br>10 [1]<br>2 4 6 2 4 6 2 4 6 2 4 6 2<br>10 [1] 10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Data Sheet: 35785298**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**231**
**High Speed Fuses**
## **Ferrule — FWC 600V: 6-32A**
## **FWC (10 x 38mm)**
2.0 voltage, Eg, (rms). UL 1.6 **Arc Voltage** 1.2 This curve gives the peak 10[3] arc voltage, UL, which 800 may appear across the as a function of theappliedfuse during its operation 600500 ——— 400 | |OT working voltage, Eg, (rms)at a power 300 eee{| Eg factor of 15%. 200 300 400 | 500 600 | 1.0 **Power Losses** 0.8 Kp === Watts loss at rated 0.60.5 7 current is given in theelectrical characteristics. 0.4 || | | ve 0.3 calculation of the powerThe curve allows the 0.2 P|Se/EEee| Yi | ft losses at load currents lower than the rated current. The correction 0.1 ALLTEL Ib factor, Kp, is given as a 30 At 40 50 60 70 80 90 100% function of the RMS load current, Ib, in % of the rated current.
## **Specifications**
**Description:** Ferrule style high speed fuses. **Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 600Vac/700Vdc (6-25A)
600Vac (30-32A)
Amps: — 6-32A
IR: — 200kA RMS Sym.
- 50kA @ 700Vdc (6-25A)
**Agency Information:** CE, UL Recognition JFHR8.E91958 6-32A. & CSA Component Acceptance file Class 1422-30, (53787) on (6-32A)
## K FREESE
## **Electrical Characteristics**
**Total Clearing I[[2]] t** 1.5 K The total clearing I[2] t at rated 1.0 voltage and at power factor of 15% are given in the electrical characteristics. For 0.5 other voltages, the clearing I[2] t is found by multiplying by 0.3 Pt tT ET TT tT 0.2 Lt tt |ttt correction factor, K, given as Pt tT tt Tt TT| YT a function of applied working 0.15 PITT Egg TE tt tI tI 100 250 400 500 600
## **Total Clearing I[[2]] t**
**Catalog Numbers**
correction factor, K, given as 0.2 tT tt Tt | YT **Rated Electrical CharacteristicsI[2] t (A[2] Sec)** a function of applied working 0.15 PITT Egg **Catalog Current Clearing Watts** 100 250 TE 400 tt tI tI 500 600 **Numbers Size RMS-Amps Pre-arc at 600V Loss** FWC-6A10F 6 4 30 1.5 FWC-8A10F 8 6 50 2.0 FWC-10A10F 10 9 70 2.5 FWC-12A10F 10 x 38mm 12 15 120 3.0 **Dimensions - mm (in)** FWC-16A10F (13⁄32” x 11⁄2”) 16 25 150 3.5 FWC-20A10F 20 34 260 4.8 38.1 10.3 FWC-25A10F 25 60 390 6.0 (1.500") (0.406") FWC-30A10FFWC-32A10F 3032 9595 600600 7.57.5 • Watts loss provided at rated current. • See accessories on page 243. **Features and Benefits** • Excellent cycling capability and DC performance can ~~_ O CCEPET.~~ • Low arc voltage and low energy let-through (I[2] t) 9.5 • Low watts loss in a compact size ~~ao~~ (0.375")
- Used with finger-safe holders/blocks
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
**Data Sheet: 720011**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**232**
**High Speed Fuses**
## **Ferrule — FWC 600V: 6-32A**
## **FWC 6-32A: 600V (10 x 38mm)**
## **Time-Current Curve**
**==> picture [305 x 360] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6 FWC-6A10F<br>4 FWC-8A10F<br>FWC-10A10F<br>2 FWC-12A10F<br>10 [2] FWC-16A10F<br>6 FWC-20A10F<br>4 FWC-25A10F<br>FWC-30A10F & FWC-32A10F<br>2<br>10 [1]<br>6<br>4<br>2<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>10 [1] 2 4 6 8 10 [2] 2 4 6 8 103<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [255 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6 FWC-30A10F & FWC-32A10F<br>4 FWC-25A10F<br>FWC-20A10F<br>FWC-16A10F<br>2<br>10 [3]<br>6<br>4<br>2<br>FWC-12A10F<br>FWC-10A10F<br>10 [2] FWC-8A10F<br>FWC-6A10F<br>6<br>4<br>2<br>10 [1]<br>2 4 6 2 4 6 2 4 6 4 6 2<br>10 [1] 10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Data Sheet: 35785306**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**233**
**High Speed Fuses**
## **Ferrule — FWP 690V/700V (IEC/UL): 1-50A, Striker Optional**
## **FWP (14 x 51mm)**
## **Arc Voltage**
|**Specifications**<br>**Description:** Ferrule style high<br>speed fuses with and without<br>indicating striker.<br>**Dimensions:** See dimensions<br>illustrations.<br>**Ratings:**<br>Volts: — 690Vac (IEC)<br>— 700Vac (UL)<br>— 800Vdc (5-50A)<br>Amps: — 1-50A<br>IR: — 200kA RMS Sym.<br>— 50kA @800Vdc<br>**Agency Information:** CE, UL Recognition JFHR2.E91958,<br>CSA Component Acceptance file Class 1422-30, 1422-90<br>(53787) for versions without indicator only. Designed and<br>tested to IEC 60269: Part 4.<br>**Electrical**<br>**Characteristics**<br>**Total Clearing I2t**<br>The total clearing I2t at<br>rated voltage and at power<br>factor of 15% are given in<br>the electrical<br>characteristics. For other<br>voltages, the clearing I2t is<br>found by multiplying by<br>correction factor, K, given<br>as a function of applied working<br>K<br>1.4<br>1.2<br>1.0<br>0.6<br>0.8<br>0.7<br>0.9<br>0.5<br>0.4<br>0.3<br>200<br>300<br>400<br>500<br>600<br>700<br>Eg<br>1)<br>2)<br>1) 5-30A Range<br>2) 32-50A Range<br>FWP with<br>striker option.<br>7?<br>i<br>,<br>/<br>=<br>===<br>|Ler<br>|<br>|<br>|<br>| |Cd<br>P|<br>|<br>|<br>[.|**Specifications**<br>**Description:** Ferrule style high<br>speed fuses with and without<br>indicating striker.<br>**Dimensions:** See dimensions<br>illustrations.<br>**Ratings:**<br>Volts: — 690Vac (IEC)<br>— 700Vac (UL)<br>— 800Vdc (5-50A)<br>Amps: — 1-50A<br>IR: — 200kA RMS Sym.<br>— 50kA @800Vdc<br>**Agency Information:** CE, UL Recognition JFHR2.E91958,<br>CSA Component Acceptance file Class 1422-30, 1422-90<br>(53787) for versions without indicator only. Designed and<br>tested to IEC 60269: Part 4.<br>**Electrical**<br>**Characteristics**<br>**Total Clearing I2t**<br>The total clearing I2t at<br>rated voltage and at power<br>factor of 15% are given in<br>the electrical<br>characteristics. For other<br>voltages, the clearing I2t is<br>found by multiplying by<br>correction factor, K, given<br>as a function of applied working<br>K<br>1.4<br>1.2<br>1.0<br>0.6<br>0.8<br>0.7<br>0.9<br>0.5<br>0.4<br>0.3<br>200<br>300<br>400<br>500<br>600<br>700<br>Eg<br>1)<br>2)<br>1) 5-30A Range<br>2) 32-50A Range<br>FWP with<br>striker option.<br>7?<br>i<br>,<br>/<br>=<br>===<br>|Ler<br>|<br>|<br>|<br>| |Cd<br>P|<br>|<br>|<br>[.|This curve gives the peak<br>arc voltage, UL, which<br>may appear across the<br>fuse during its operation<br>as a function of theapplied<br>working voltage, Eg, (rms)<br>at a power factor of 15%.<br>**Power Losses**<br>Watts loss at rated current<br>is given in the electrical<br>characteristics. The curve<br>allows the calculation of<br>the power losses at load<br>currents lower than the<br>rated current. The<br>correction factor, Kp, is<br>given as a function of the<br>RMS load current, Ib, in %<br>of the rated current.<br>**Catalog Numbers**<br>**Rated**<br>**I2t (A2 Sec)**<br>**Catalog**<br>**Current**<br>**Minimum**<br>**Clearing At**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Melting**<br>**Rated Voltage**<br>**Loss**<br>Without Striker<br>FWP-1A14F<br>1<br>—<br>—<br>—<br>FWP-2A14F<br>2<br>—<br>—<br>—<br>FWP-2.5A14F<br>2.5<br>—<br>—<br>—<br>FWP-3A14F<br>3<br>—<br>—<br>—<br>FWP-4A14F<br>4<br>—<br>—<br>—<br>FWP-5A14F<br>14 x 51mm<br>5<br>1.6<br>11.0<br>1.5<br>FWP-10A14F<br>(9⁄16" x 2")<br>10<br>3.6<br>38.5<br>4<br>FWP-15A14F<br>15<br>8.6<br>70<br>5.5<br>FWP-20A14F<br>20<br>26.0<br>230<br>6<br>UL<br>1.4<br>1.2<br>103<br>6<br>8<br>7<br>9<br>5<br>4<br>3<br>200<br>300<br>400<br>500<br>600<br>700<br>Eg<br>Kp<br>1.0<br>0.8<br>0.4<br>0.5<br>0.6<br>0.3<br>0.2<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ib<br>**Electrical Characteristics**<br>EEE<br>=————<br>| {|<br>|<br>|<br>[| |<br>P|<br>|<br>|[|<br>Pt ft ft|<br>=—————<br>ss<br>Ft tt Yt<br>|<br>||<br>|<br>Yi | [|<br>|<br>IA Et|<br>Att tt<br>~~LLL~~|This curve gives the peak<br>arc voltage, UL, which<br>may appear across the<br>fuse during its operation<br>as a function of theapplied<br>working voltage, Eg, (rms)<br>at a power factor of 15%.<br>**Power Losses**<br>Watts loss at rated current<br>is given in the electrical<br>characteristics. The curve<br>allows the calculation of<br>the power losses at load<br>currents lower than the<br>rated current. The<br>correction factor, Kp, is<br>given as a function of the<br>RMS load current, Ib, in %<br>of the rated current.<br>**Catalog Numbers**<br>**Rated**<br>**I2t (A2 Sec)**<br>**Catalog**<br>**Current**<br>**Minimum**<br>**Clearing At**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Melting**<br>**Rated Voltage**<br>**Loss**<br>Without Striker<br>FWP-1A14F<br>1<br>—<br>—<br>—<br>FWP-2A14F<br>2<br>—<br>—<br>—<br>FWP-2.5A14F<br>2.5<br>—<br>—<br>—<br>FWP-3A14F<br>3<br>—<br>—<br>—<br>FWP-4A14F<br>4<br>—<br>—<br>—<br>FWP-5A14F<br>14 x 51mm<br>5<br>1.6<br>11.0<br>1.5<br>FWP-10A14F<br>(9⁄16" x 2")<br>10<br>3.6<br>38.5<br>4<br>FWP-15A14F<br>15<br>8.6<br>70<br>5.5<br>FWP-20A14F<br>20<br>26.0<br>230<br>6<br>UL<br>1.4<br>1.2<br>103<br>6<br>8<br>7<br>9<br>5<br>4<br>3<br>200<br>300<br>400<br>500<br>600<br>700<br>Eg<br>Kp<br>1.0<br>0.8<br>0.4<br>0.5<br>0.6<br>0.3<br>0.2<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ib<br>**Electrical Characteristics**<br>EEE<br>=————<br>| {|<br>|<br>|<br>[| |<br>P|<br>|<br>|[|<br>Pt ft ft|<br>=—————<br>ss<br>Ft tt Yt<br>|<br>||<br>|<br>Yi | [|<br>|<br>IA Et|<br>Att tt<br>~~LLL~~|This curve gives the peak<br>arc voltage, UL, which<br>may appear across the<br>fuse during its operation<br>as a function of theapplied<br>working voltage, Eg, (rms)<br>at a power factor of 15%.<br>**Power Losses**<br>Watts loss at rated current<br>is given in the electrical<br>characteristics. The curve<br>allows the calculation of<br>the power losses at load<br>currents lower than the<br>rated current. The<br>correction factor, Kp, is<br>given as a function of the<br>RMS load current, Ib, in %<br>of the rated current.<br>**Catalog Numbers**<br>**Rated**<br>**I2t (A2 Sec)**<br>**Catalog**<br>**Current**<br>**Minimum**<br>**Clearing At**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Melting**<br>**Rated Voltage**<br>**Loss**<br>Without Striker<br>FWP-1A14F<br>1<br>—<br>—<br>—<br>FWP-2A14F<br>2<br>—<br>—<br>—<br>FWP-2.5A14F<br>2.5<br>—<br>—<br>—<br>FWP-3A14F<br>3<br>—<br>—<br>—<br>FWP-4A14F<br>4<br>—<br>—<br>—<br>FWP-5A14F<br>14 x 51mm<br>5<br>1.6<br>11.0<br>1.5<br>FWP-10A14F<br>(9⁄16" x 2")<br>10<br>3.6<br>38.5<br>4<br>FWP-15A14F<br>15<br>8.6<br>70<br>5.5<br>FWP-20A14F<br>20<br>26.0<br>230<br>6<br>UL<br>1.4<br>1.2<br>103<br>6<br>8<br>7<br>9<br>5<br>4<br>3<br>200<br>300<br>400<br>500<br>600<br>700<br>Eg<br>Kp<br>1.0<br>0.8<br>0.4<br>0.5<br>0.6<br>0.3<br>0.2<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ib<br>**Electrical Characteristics**<br>EEE<br>=————<br>| {|<br>|<br>|<br>[| |<br>P|<br>|<br>|[|<br>Pt ft ft|<br>=—————<br>ss<br>Ft tt Yt<br>|<br>||<br>|<br>Yi | [|<br>|<br>IA Et|<br>Att tt<br>~~LLL~~|
|---|---|---|---|---|
|voltage, Eg, (rms).||FWP-25A14F<br>25<br>FWP-30A14F<br>30|46.5<br>375<br>7<br>58<br>485<br>9||
|||FWP-32A14F<br>32|68<br>600<br>7.6||
|**Dimensions - mm (in)**||FWP-40A14F<br>40<br>FWP-50A14F<br>50|84<br>750<br>8<br>200<br>1800<br>9||
|**Without Striker**||With Striker*|||
|||FWP-10A14FI<br>10|3.6<br>38.5<br>4||
|50.8<br>(2.000")<br>14.3<br>(0.563")<br>~~TDO~~|~~O~~|FWP-15A14FI<br>15<br>FWP-20A14FI<br>14 x 51mm<br>20<br>FWP-25A14FI<br>(9⁄16” x 2”)<br>25<br>FWP-30A14FI<br>30<br>FWP-32A14FI<br>32<br>FWP-40A14FI<br>40<br>FWP-50A14FI<br>50|8.6<br>70<br>5.5<br>26.0<br>230<br>6<br>46.5<br>375<br>7<br>58<br>485<br>9<br>68<br>600<br>7.6<br>84<br>750<br>8<br>200<br>1800<br>9||
Amps: — 1-50A
**Agency Information:** CE, UL Recognition JFHR2.E91958, CSA Component Acceptance file Class 1422-30, 1422-90 (53787) for versions without indicator only. Designed and tested to IEC 60269: Part 4.
## **Without Striker**
**==> picture [240 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
50.8 14.3<br>(2.000") (0.563")<br>TD O<br>15.5<br>te (0.610")<br>With Striker<br>59 (2.323")<br>51 (2.00")<br>14.3<br>(0.563") 13 (0.511")<br>o - -©- SEES<br>5 (0.197")<br>**----- End of picture text -----**<br>
*Striker range is 600Vdc only
- Watts loss provided at rated current.
- See accessories on page 243.
## **With Striker**
## **Features and Benefits**
- Excellent cycling capability and DC performance
- Low arc voltage and low energy let-through ([I2] t)
- Low watts loss in a compact size
- Used with finger-safe holders/blocks
## **Data Sheet: 720025**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**234**
**High Speed Fuses**
## **Ferrule — FWP 690V/700V (IEC/UL): 1-50A, Striker Optional**
## **Without Striker FWP 5-50A: 660V/700V (14 x 51mm)**
## **Time-Current Curve**
**==> picture [252 x 336] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>FWP-25A14F<br>10 [2] FWP-30A14F<br>6 FWP-32A14F<br>4 FWP-40A14F<br>FWP-50A14F<br>2<br>10 [1]<br>6<br>4<br>2<br>10 [0]<br>6<br>4 FWP-5A14F<br>FWP-10A14F<br>2 FWP-15A14F<br>FWP-20A14F<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>2 4 6 8 10 [1] 2 4 6 8 10 [2] 2 4 6 8 103<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [252 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>FWP-50A14F<br>6 FWP-40A14F<br>4 FWP-32A14F<br>FWP-30A14F<br>FWP-25A14F<br>2<br>10 [3]<br>6<br>4<br>2<br>FWP-20A14F<br>10 [2] FWP-15A14FFWP-10A14F<br>FWP-5A14F<br>6<br>4<br>2<br>10 [1]<br>10 [1] 2 4 6 10 [2] 2 4 6 10 [3] 2 4 6 10 [4] 2 4 6 10 [5] 2<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Data Sheet: 35785307**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**235**
**High Speed Fuses**
## **Ferrule — FWP 690V/700V (IEC/UL): 20-100A, Striker Optional**
## **FWP (22 x 58mm)**
## **Specifications**
**Description:** Ferrule style high speed fuses with and without indicating striker.
**Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 690Vac (IEC)
**==> picture [209 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
— 700Vac (UL)<br>FWP with<br>— 500Vac striker<br>option.<br>**----- End of picture text -----**<br>
- 500Vdc (20-100A)
Amps: — 20-100A IR: — 200kA RMS Sym.
- 50kA @ 500Vdc
**Agency Information:** CE, UL Recognition JFHR2.E91958, CSA Component Acceptance file Class 1422-30, 1422-90 (53787)
## **Electrical**
## **Characteristics**
**==> picture [240 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.4<br>Total Clearing I [2] t 1.2 K<br>1.0<br>rated voltage and at powerThe total clearing I [2] t at 0.90.8 rrrs ee ee ee a<br>factor of 15% are given in 0.7 fF {| |<br>0.6 ee<br>the electrical<br>characteristics. For other 0.5 ae<br>voltages, the clearing I [2] t is 0.4 a7| [| |<br>found by multiplying by Eg<br>correction factor, K, given 0.3 TTT<br>as a function of applied 200 300 400 500 600 700<br>working voltage, Eg, (rms).<br>**----- End of picture text -----**<br>
## **Dimensions - mm (in)**
## **Without Striker**
**==> picture [174 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
58.0 22.2<br>(2.283") (0.875")<br>mene<br>15.0<br>ke (0.591")<br>66 (2.598")<br>58 (2.283")<br>5<br>(0.197") 16 (0.630"<br>=a<br>| ae<br>@ /FEEE<br>22.2 (0.874")<br>**----- End of picture text -----**<br>
## **With Striker**
## **Arc Voltage**
**Arc Voltage** 1.4 This curve gives the peak 1.210[3] UL arc voltage, UL, which 9 ypSS may appear across the 8 fuse during its operation 7 as a function of theapplied 6 working voltage, Eg, (rms) 5 ooo at a power factor of 15%. 4 Pe E g 3 200 TET 300 400 500 600 700 **Power Losses** 1.0 Watts loss at rated current Kp 0.8 ====—— is given in the electricalcharacteristics. The curve 0.60.5 ee, allows the calculation of 0.4 P| | tT YI | the power losses at load 0.3 | [ {|Vit|] currents lower than therated current. The 0.2 LYLE correction factor, Kp, is given as a function of the Att 1 RMS load current, Ib, in % 0.1 YELLE Ib of the rated current. 30 40 50 60 70 80 90 100%
## **Catalog Numbers**
|||**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|
|**Catalog**<br>**Numbers**|**Size**|**Electrical Characteristics**<br>**t (ASec)**||||
|||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2** **Sec)**||**Watts**<br>**Loss**|
||||**Minimum**<br>**Melting**|**Clearing At**<br>**Rated Voltage**||
|Without Striker<br>FWP-20A22F<br>FWP-25A22F<br>FWP-32A22F<br>FWP-40A22F<br>FWP-50A22F<br>FWP-63A22F<br>FWP-80A22F<br>FWP-100A22F|22 x 58mm<br>(7⁄8" x 29⁄32")|20<br>25<br>32<br>40<br>50<br>63<br>80<br>100*|19.0<br>34.0<br>53.5<br>68<br>135<br>280<br>600<br>1100|260<br>410<br>605<br>750<br>1600<br>3080<br>6600<br>12500|5<br>6<br>8<br>9<br>9.5<br>11<br>13.5<br>16|
|With Striker<br>FWP-20A22FI<br>FWP-25A22FI<br>FWP-32A22FI<br>FWP-40A22FI<br>FWP-50A22FI<br>FWP-63A22FI<br>FWP-80A22FI<br>FWP-100A22FI|22 x 58mm<br>(7⁄8" x 29⁄32")|20<br>25<br>32<br>40<br>50<br>63<br>80<br>100*|19.0<br>34.0<br>53.5<br>68<br>135<br>280<br>600<br>1100|260<br>410<br>605<br>750<br>1600<br>3080<br>6600<br>12500|5<br>6<br>8<br>9<br>9.5<br>11<br>13.5<br>16|
*IEC/UL Voltage rating 690/700
## **Features and Benefits**
- Excellent cycling capability and DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss in a compact size
- Used with finger-safe holders/blocks
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
## **Data Sheet: 720026**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**236**
**High Speed Fuses**
## **Ferrule — FWP 690V/700V (IEC/UL): 20-100A, Striker Optional**
## **Without Striker FWP 20-100A: 660V/700V (22 x 58mm)**
## **Time-Current Curve**
**==> picture [252 x 528] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>FWP-50A22F<br>10 [2] FWP-63A22F<br>6 FWP-80A22F<br>4 FWP-100A22F<br>2<br>10 [1]<br>6<br>4<br>2 FWP-20A22F<br>FWP-25A22F<br>10 [0] FWP-32A22F<br>6 FWP-40A22F<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3 ]<br>6<br>4<br>2<br>10 [–4]<br>10 [1] 2 4 6 8 10 [2] 2 4 6 8 103<br>Prospective Current In Amps RMS<br>Peak Let-Through Curve<br>10 [4]<br>FWP-100A22F<br>6 FWP-80A22F<br>FWP-63A22F<br>4 FWP-50A22F<br>2<br>10 [3]<br>6 FWP-40A22F<br>4 FWP-32A22F<br>FWP-25A22F<br>FWP-20A22F<br>2<br>10 [2]<br>10 [2] 2 4 6 10 [3] 2 4 6 10 [4] 2 4 6 10 [5] 2<br>Prospective Short-Circuit Current Symmetrical RMS<br>Virtual Pre-Arcing Time In Seconds<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Data Sheet: 35785291**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**237**
**High Speed Fuses**
## **Ferrule — FWK 750V: 5-60A**
## **FWK 5-30A (20 x 127mm 35-60A (25 x 146mm)**
## **Specifications**
**Description:** Ferrule style high speed fuses. **Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts: — 750Vac
- 750Vdc (Time constant = 10-15mS)
Amps: — 5-60A
## **Features and Benefits**
- Excellent cycling capability and DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss in a compact size
- Used with finger-safe holders/blocks
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
IR: — 45kA RMS Sym.
## **Agency Information:** CE
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Size**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|
|||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**||
||||**Pre-arc**|**Clearing**<br>**at 750Vdc**|
|FWK-5A20F<br>FWK-8A20F<br>FWK-10A20F<br>FWK-15A20F<br>FWK-20A20F<br>FWK-25A20F<br>FWK-30A20F|20 x 127mm<br>(13⁄16” x 5”)|**Amps**<br>5<br>8<br>10<br>15<br>20<br>25<br>30|8.5<br>50<br>95<br>100<br>125<br>400<br>800|16<br>100<br>200<br>240<br>315<br>1100<br>2600|
|FWK-30A20F<br>FWK-35A25F<br>FWK-40A25F<br>FWK-50A25F<br>FWK-60A25F|25 x 146mm<br>(1” x 53⁄4”)|30<br>35<br>40<br>50<br>60|800<br>1300<br>1600<br>3100<br>5900|2600<br>4300<br>5300<br>12000<br>24000|
Recommended fuseholders for 20x127, -2, -3 Recommended fuseclips for 20x127, 1A1837 Recommended fuseclips for 25x146, A3354705
## **Dimensions - mm (in)**
Fig. 1: 5-30A
127.0 20.5 (5.000") (0.807") — ~~ee~~ t) 16.0 ~~a~~ (0.630") ©
Et) 16.0 ~~a~~ (0.630") © Fig. 2: 35-60A 146.05 25.4 (5.75") (1") ~~To©~~ 20.64 (0.813")
**Data Sheet: 720039**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**238**
**High Speed Fuses**
## **Ferrule — FWK 750V: 5-60A**
## **FWK 750V: 5-30A (20 x 127mm) 35-60A (25 x 146mm)**
## **Time-Current Curve**
**==> picture [270 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2 FWK-15A20F<br>FWK-20A20F<br>10 [3] FWK-25A20F<br>6 FWK-30A20F<br>4 FWK-40A25F<br>2 FWK-50A25F<br>FWK-60A25F<br>10 [2]<br>6<br>4<br>2<br>10 [1]<br>6<br>4<br>2<br>10 [0]<br>6<br>4 FWK-5A20F<br>2 FWK-8A20F<br>FWK-10A20F<br>10±1<br>6<br>4<br>2<br>10±2<br>4x10±3<br>2 4 6 8 10 [1] 2 4 6 8 10 [2] 2 4 6 8 10 [3]<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
**Data Sheet: 720028**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**239**
**High Speed Fuses**
## **Ferrule — FWJ 1000V: 20-30A**
## **FWJ (14 x 67mm)**
## **Arc Voltage**
**Arc Voltage** 2000 This curve gives the peak 1600 LYELL UL arc voltage, UL, which may appear across the 1200 TUT fuse during its operation as a function of theapplied 800 ACL working voltage, Eg, (rms)at a power factor of 15%. 400 ACT E g LEELA 200 600 1000 1400 1800 **Power Losses** 1.0 Watts loss at rated current 0.8 SSS Kp is given in the electricalcharacteristics. The curve 0.60.5 ee allows the calculation of 0.4 aa a the power losses at load 0.3 currents lower than therated current. The 0.2 PtTATtT Yi ft | correction factor, Kp, is | given as a function of the 0.1 Ib RMS load current, Ib, in % 30 fo 40 50 60 70 80 90 100% of the rated current. ALLITT
## **Specifications**
**Description:** Ferrule style high speed fuses.
**Dimensions:** See dimensions illustration.
## **Ratings:**
Volts: — 1000Vac/800Vdc Amps: — 20-30A
- IR: — 25kA RMS Sym. — 20kA @ 800Vdc
**Agency Information:** CE, UL Recognized JFHR2.E91958
## **Electrical**
|**Characteristics**<br>**Total Clearing I2t**<br>The total clearing I2t at<br>rated voltage and at power<br>factor of 15% are given in<br>the electrical<br>characteristics. For other<br>voltages, the clearing I2t is<br>found by multiplying by<br>correction factor, K, given<br>as a function of applied<br>working voltage, Eg, (rms).<br>1000<br>800<br>500<br>200<br>1.5<br>1.0<br>0.5<br>0.3<br>0.2<br>0.15<br>Eg<br>K<br>j=========<br>==s=SSSS==<br>He<br>pee<br>PTEEELLE<br>Pttt tT **t**t yt<br>Ptttt<br>t yt<br>a|**Characteristics**<br>**Total Clearing I2t**<br>The total clearing I2t at<br>rated voltage and at power<br>factor of 15% are given in<br>the electrical<br>characteristics. For other<br>voltages, the clearing I2t is<br>found by multiplying by<br>correction factor, K, given<br>as a function of applied<br>working voltage, Eg, (rms).<br>1000<br>800<br>500<br>200<br>1.5<br>1.0<br>0.5<br>0.3<br>0.2<br>0.15<br>Eg<br>K<br>j=========<br>==s=SSSS==<br>He<br>pee<br>PTEEELLE<br>Pttt tT **t**t yt<br>Ptttt<br>t yt<br>a|||allows the calculation of<br>the power losses at load<br>currents lower than therated current. The<br>rated current. The<br>correction factor, Kp, is<br>given as a function of the<br>RMS load current, Ib, in %<br>of the rated current.<br>**Catalog Numbers**<br>**Electrical Characteristics**<br>**Rated**<br>**I2t (A2 Sec)**<br>**Catalog**<br>**Current**<br>**Clearing**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Pre-arc**<br>**at 1000V**<br>**Loss**<br>FWJ-20A14F<br>14 x 67mm<br>20<br>25<br>220<br>9<br>FWJ-25A14F<br>(9⁄16” x 25⁄8”)<br>25<br>33<br>350<br>11<br>FWJ-30A14F<br>30<br>52<br>450<br>14<br>• Watts loss provided at rated current.<br>0.4<br>0.3<br>0.2<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ibb<br>aa a<br>PtTATtT tT Yi ft ||<br>TATtT|<br>fo<br>ALLITTITT<br> ~~i Py~~|allows the calculation of<br>the power losses at load<br>currents lower than therated current. The<br>rated current. The<br>correction factor, Kp, is<br>given as a function of the<br>RMS load current, Ib, in %<br>of the rated current.<br>**Catalog Numbers**<br>**Electrical Characteristics**<br>**Rated**<br>**I2t (A2 Sec)**<br>**Catalog**<br>**Current**<br>**Clearing**<br>**Watts**<br>**Numbers**<br>**Size**<br>**RMS-Amps**<br>**Pre-arc**<br>**at 1000V**<br>**Loss**<br>FWJ-20A14F<br>14 x 67mm<br>20<br>25<br>220<br>9<br>FWJ-25A14F<br>(9⁄16” x 25⁄8”)<br>25<br>33<br>350<br>11<br>FWJ-30A14F<br>30<br>52<br>450<br>14<br>• Watts loss provided at rated current.<br>0.4<br>0.3<br>0.2<br>0.1<br>30<br>40<br>50<br>60<br>70<br>80<br>90 100%<br>Ibb<br>aa a<br>PtTATtT tT Yi ft ||<br>TATtT|<br>fo<br>ALLITTITT<br> ~~i Py~~|
|---|---|---|---|---|---|
|**Dimensions - mm (in)**|**Dimensions - mm (in)**||||• See accessories on page 243.|
|66.7<br>(2.626")<br>14.5<br>(0.571")<br>~~— —~~<br>~~fe~~|||||**Features and Benefits**<br>• Excellent cycling capability and DC performance<br>• Low arc voltage and low energy let-through (I2t)<br>• Low watts loss in a compact size|
||||||• Used with finger-safe holders/blocks|
||||||**Typical Applications**|
||||||• DC Common bus|
||15.9<br>(0.625")<br>~~=~~||||• DC Drives<br>•Power converters/rectifiers|
## **Characteristics**
## **Total Clearing I[2] t**
**Dimensions - mm (in)**
- Power converters/rectifiers
- Reduced voltage starters
## **Fuseclips:**
- Catalog Number: 5591 (see data sheet 2132)
**Data Sheet: 35785031**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**240**
**High Speed Fuses**
## **Ferrule — FWJ 1000V: 20-30A**
## **FWJ 20-30A: 1000V (14 x 67mm)**
## **Time-Current Curve**
**==> picture [231 x 375] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2<br>10 [3]<br>6<br>4<br>2<br>10 [2]<br>6<br>4<br>2<br>10 [1]<br>6<br>4<br>FWJ-20A14F<br>2 FWJ-25A14F<br>FWJ-30A14F<br>10 [0]<br>6<br>4<br>2<br>10 [–1]<br>6<br>4<br>2<br>10 [–2]<br>6<br>4<br>2<br>10 [–3]<br>6<br>4<br>2<br>10 [–4]<br>10 [1] 2 4 6 8 10 [2] 2 4 6 8 103<br>Prospective Current In Amps RMS<br>Virtual Pre-Arcing Time In Seconds<br>**----- End of picture text -----**<br>
## **Peak Let-Through Curve**
**==> picture [238 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 [4]<br>6<br>4<br>2 FWJ-30A14F<br>FWJ-25A14F<br>FWJ-20A14F<br>10 [3]<br>6<br>4<br>2<br>10 [2]<br>6<br>4<br>2<br>10 [1]<br>2 4 6 2 4 6 2 4 6 2 4 6 2<br>10 [1] 10 [2] 10 [3] 10 [4] 10 [5]<br>Prospective Short-Circuit Current Symmetrical RMS<br>Peak Let-Through Current<br>**----- End of picture text -----**<br>
**Data Sheet: 35785315**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**241**
**High Speed Fuses**
## **Ferrule — FWS/FWL 1000Vdc: 2-30A**
## **FWS 2-15A (20 x 127mm) FWL 20-30A (20 x 127mm)**
## **Specifications**
**Description:** Ferrule style full range fuses.
**Dimensions:** See dimensions illustrations.
## **Ratings:**
Volts: — 1200Vac (FWL 20-30A) — 1400Vac (FWS 8-15A) — 2100Vac (FWS 2-6A)
## **Features and Benefits**
- Excellent cycling capability and DC performance
- Low arc voltage and low energy let-through (I[2] t)
- Low watts loss in a compact size
- Used with finger-safe holders/blocks
## **Typical Applications**
- DC Common bus
- DC Drives
- Power converters/rectifiers
- Reduced voltage starters
- Traction aux circuits
- Capacitor protection
- 1000Vdc (FWL/FWS 2-30)
- Amps: — 2-30A
- IR: — 45kA RMS Sym.
- 30kA @ 1000Vdc
## **Agency Information:** CE, IEC 60077
## **FWL/FWS 2-30A: 1000Vdc 2-30A (20 x 127mm)**
## **Time-Current Curve**
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Size**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|
|---|---|---|---|---|---|
|||**Rated**<br>**Current**<br>**RMS-Amps**|**I2t (A2 Sec)**||**Watts**<br>**Loss**|
||||**Pre-arc**|**Clearing**<br>**at 1000Vdc**||
|FWS-2A20F<br>FWS-6A20F<br>FWS-8A20F<br>FWS-10A20F<br>FWS-12A20F<br>FWS-15A20F|20 x 127mm<br>(13⁄16” x 5”)|2<br>6<br>8<br>10<br>12<br>15|0.8<br>27<br>64<br>118<br>170<br>209|2.4<br>81<br>192<br>277<br>380<br>500|4.4<br>6.7<br>7.6<br>3.0<br>3.4<br>5.0|
|FWL-20A20F<br>FWL-25A20F<br>FWL-30A20F|20 x 127mm<br>(<br>13⁄16” x 5”)|20<br>25<br>30|675<br>1200<br>1850|1550<br>2760<br>4300|5.9<br>6.5<br>7.5|
- ADD “I” to catalog number for indicating version.
- Enclosed finger-safe fuse holder – CH127
- See accessories on page 243.
• Watts loss provided at rated current.
**==> picture [213 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions - mm (in)<br>127.0 20.5<br>k*——— (5.000") — | (0.807") —»|<br>16.0<br>— { (0.630")<br>**----- End of picture text -----**<br>
## **Indicating Version – Dimensions - mm (in)**
**==> picture [215 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
8.0<br>(0.315")<br>127.0 20.5<br>(5.000") (0.807")<br>2.0<br>16.0<br>2.0<br>(0.630") | S<br>(0.079")<br>Data Sheet: 720040<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**242**
**High Speed Fuses**
## **Ferrule Fuse Accessories**
## **Fuse Holders**
## **Specifications**
**Catalog Symbol:** CH Series **Description:** DIN-Rail mount fuse holders
## **Agency Information:**
UL File E14853, Guide IZLT Listed, IZLT2 Recognized CSA: File 47235, CHPV and CHM - Class 6225-30, CHCC - Class 6225-01
**Ratings:** 600V/30A (UL) 690V/32A (IEC)
## **Features and Benefits**
## **Fuse Blocks**
**Specifications Catalog Symbol:** J70100, J70032
**Description:** Fuse blocks for 22x58mm & 14x51mm fuses.
## **Ratings:**
Volts: — 700Vac/dc Amps: — 32-100A
Withstand: — 200kA RMS Sym.
**Agency Information:** CE, UL Recognized, Guide IZLT2, File E14853
**Flammability Rating:** UL 94V0
- Finger-safe design - No exposed contacts
- DIN-Rail mount (35mm) - Fits standard mounting rails
- Optional open fuse indication lights tells fuse status at a glance
- Handle/fusepuller easily installs and removes fuses
- Available in single and multi-pole configurations
- Wire ready lugs and spade terminal connections save installation time
- CE marking
- Available up to 1000Vdc
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Fuse**<br>**Size**|**Amps**|**Poles**|**Max Wire**<br>**Size**|**Terminations**|
|---|---|---|---|---|---|
|J70032-1CR||**Amps**<br>32|1|#2||
|J70032-2CR|14x51|32|2|#2|Box Lug w/|
|J70032-3CR||32|3|#2|Box Lug w/<br>Retaining Clip<br>Box Lugw/|
|J70100-1CR||100|1|#2|Retaining Clip<br>Retaining Clip|
|J70100-2CR|22x58<br>22x58|100|2|#2||
|J70100-3CR||100|3|#2||
- PLC device available for remote monitoring
## **Typical Applications**
- Switchboard panel, control consoles, small motors, transformers, and similar applications
## **Recommended Cooper Bussmann Fuse Types**
Class CC North American Class CC Fuses - LP-CC, FNQ-R, KTK-R
- 10 x 38 North American Midget Fuses - FNQ, KTK, AGU, BAF, BAN, FNM, FWA, FWC, & PV
- 14 x 51 FWX, FWH, FWP & NON
- 22 x 58 FWP
See pages 274-280 for CH Series fuse holder information.
**Data Sheet: 2053**
**Data Sheet: 1211**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**243**
## High speed fuses
Faster lead-time. Better protection. More energy efficient.
**244**
**IEC & British Standard Fuses**
## **IEC and British Standard Fuses**
## **Section Contents**
**Page**
**==> picture [255 x 349] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Application Data . . . . . . . . . . . . . . . . . . . . .245-246|
|CSA Type P and Type D fuses|
|(CDS, CDN & PON) . . . . . . . . . . . . . . . . . . . . . . . . . . . .247|
|Tron|[™]|HRC Form II Class C fuses|
|(CGL Form II Class C) . . . . . . . . . . . . . . . . . . . . . . . . . . 248|
|HRCI Industrial ceramic body fuses (CIF21 HRCI-CA &|
|CIF06 HRCI-CB)|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249|
|HRCI-J Fast-acting fuses (CJ HRCI-J) . . . . . . . . . . . . . . . 250|
|HRCI-Miscellaneous Type K fuses (CIH, CIK &|
|CIL HRCI-MISC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|251|
|HRC Form II current-limiting fuses . . . . . . . . . . . . . . . . . .252|
|BS 88 British Standard low voltage fuses (SSD, NSD,|
|ESD & STD, NITD, AAO, BAO, OSD, CEO,|
|DEO BS 88 Part 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253|
|BS 88 British Standard low voltage fuses (AC, AD, BC,|
|BD, CD, DD, ED, EFS & EF, FF, FG, GF, GG,|
|GH BS 88) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254|
|DIN Style Type D (D16, D27, D33, D125 Type D) . . . . . . 255|
|Neozed low voltage fuses (NZ01, NZ02 Type D0) . . . . . .|255|
|NH HRC Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . .|256-259|
|Class gG/gL IEC Industrial ferrule fuses (C08G, C08M,|
|C10G, C10M, C14G, C14M, C22G, C22M)|. . . . . . . . . . 260|
|Class aM IEC Industrial ferrule fuses (C08M, C10M,|
|C14M, C22M) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261|
|Class aM & gG/gL IEC Industrial ferrule fuses with striker|
|(C14G_S, C22G_S, C14M_S, C22M_S) . . . . . . . . . . . . . 262|
|HRC fuse holders|
|CAMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263|
|SAFEloc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263|
**----- End of picture text -----**<br>
## **Application Data**
The standard range of fuses for low voltage industrial and general purpose applications meet the requirements of BS 88 and IEC 60269. By using advanced fuse technology, current ratings up to 400A have compact dimensions, but retain standard dimensional and performance requirements. These designs are for 315/240V systems. The standard range of fuses are available from 2-1250A in the following tag forms: Offset Blade - Offset Bolted - Center Bolted.
Supplementary ranges cover applications up to 660Vac and 500Vdc including those with nonstandard tag fixings.
Bussmann fuses are manufactured under quality systems independently assessed to BS 5750 (ISO 9002) and appropriate ratings carry the ASTA 20 endorsement.
Selecting fuses is relatively simple and effective. The following notes cover the majority of applications. For further information contact our Application Engineers at toll free phone: 855-287-7626 (855-BUSSMANN).
## **Circuit Loading**
The current rating of the fuse should not be less than the full load current of the circuit. The circuit should be so designed that small overloads of long duration will not be of frequent occurrence.
## **Cable Ratings & Protection**
There is an increasing move away from 70°C PVC insulation to materials that are more environmentally friendly, for example 90°C XLPE. The ratings of fusegear, switches, accessories, etc. are generally based upon the equipment being connected to conductors intended to be operated at a temperature not exceeding 70°C in normal service.
In view of the above, it is recommended that the practice of designs based upon conductor temperatures of 70°C be regarded as the norm. The equipment manufacturer should be consulted to ascertain the reduction of nominal current rating of the equipment if conductor temperatures exceeding 70°C are used. In addition, an overriding factor is often voltage drop.
Fuses with gG characteristics protect associated cables against both overload and short-circuit current, provided that the current rating of the fuse 1N is equal or less than the current carrying capacity of the cable 1z.
Scan this tag to get the latest product information for IEC and British Standard Fuses.
In motor circuits, the motor starter will provide the overload protection and the fuses will provide the short-circuit protection. The maximum fuse size that can be used depends upon the type of cable used and is determined using the appropriate K factor. The following table gives the maximum sizes of fuses that are recommended for two popular cables with copper conductors, 70°C PVC (K = 115) and 90°C thermosetting (K = 143).
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**245**
**IEC & British Standard Fuses**
## **Application Data for BS Low Voltage Fuses**
|**Cable Size (mm2)**|**Max. Fuse Rating (amps)**|**Max. Fuse Rating (amps)**|
|---|---|---|
||**K= 115**|**K= 143**|
|<br>1|16|16|
|1,5|20|25*|
|2.5|32*|32*|
|4|50*|50*|
|6|63*|63*|
|10|100*|125*|
|16|125*|160*|
|25|200*|250*|
|35|315*|355*|
|50|400*|500|
|70|560|630|
|95|710|800|
|120|800|1000|
* Extended Motor Circuit dual ratings can be used.
## **Protection Against Electrical Shock**
For a TN System, a disconnecting time not exceeding 5s is permitted for a distribution circuit. The maximum values of earth fault loop impedance (Zs) of 240V for Bussmann gG fuses to BS 88: Parts 2 and 6 are:
|**Rating (A)**<br>**Zs (Ohms) **|**Rating (A)**<br>**Zs (Ohms)**|**Rating (A) Zs (Ohms)**|
|---|---|---|
|<br> <br>6<br>14|<br> <br>50<br>1.1|<br>250<br>0.16|
|10<br>7.7|63<br>0.86|315<br>0.13|
|16<br>4.3|80<br>0.60|400<br>0.096|
|20<br>3.0|100<br>0.44|500<br>0.073|
|25<br>2.4|125<br>0.35|630<br>0.054|
|32<br>1.9|160<br>0.27|800<br>0.044|
|40<br>1.4|200<br>0.20||
## **Ambient Temperature**
The derating, in terms of current, of 0.5% per °C above an ambient of 35°C is recommended.
## **Interrupting Rating**
The standardized interrupting rating values are 80kA for voltages of 415Vac and above, and 40kA for DC applications. The 240Vac designs have an interrupting rating of 50kA.
## **Coordination Ratio**
All fuses to BS 88 Parts 2 and 6 will give a coordination ratio of 2:1; and for most practical situations a ratio of 1.6:1 (two steps in the R10 series). Example: an upstream fuse rated at 160A will coordinate with a downstream fuse rated at 100A.
## **Current and Energy Limitation**
The range of fuses have pre-arcing I[2] t values towards the bottom limits of BS 88 Parts 2 and 6. This ensures excellent current and energy limitation. They also have lower power losses at rated current. This assists in the appropriate interchangeability with other makes of fuses.
## **Transformers**
When fuses are used on the primary side of transformers, the normal fuse current rating should be at least twice the nominal transformer primary current.
## **Fluorescent Lighting**
The normal fuse current rating should be at least twice the normal full load current of the maximum number of lights to be simultaneously switched.
## **Capacitor Circuits**
For power factor correction in capacitor circuits, the fuse should be chosen with a current rating greater than 1.5 times the rated capacitor current. This takes into account the high inrush current, circuit harmonics and capacitor tolerances.
## **Motor Circuits**
In motor circuits, the fuse has to withstand the motor's starting current and often requires a higher rating than the motor's full load current. Coordination recommendations are made by the manufacturers of motor starters in accordance with IEC 60947-4-1. To get Type 2 coordination with fuses, tests are performed with the latest gG or gM fuses to BS 88 or IEC 60269 that have pre-arcing I[2] t values towards the bottom of specified limits. This means that Bussmann fuses are suitable to provide Type 2 coordination.
Extended dual ratings of motor circuit protection fuses with gM characteristics are available in most popular fuse sizes to extend the use of associated equipment with appropriate economies. In the majority of applications, gG fuses are used. It is not essential to use gM fuses for motor circuit protection, they simply extend the utilization of standard equipment.
Below is a table of recommended fuses at 415V. In most applications, the run-up time is less than 5 seconds and duty is infrequent - no more than twice per hour. The next larger rating should be used for more demanding applications.
|**Rating Motor**|**Rating Motor**|**Direct On-line**|**Direct On-line**|**Asst. Start**<br>**Standard**<br>**(gG)**|
|---|---|---|---|---|
|||**Standard**<br>**(gG)**|**Motor Circuit**<br>**(gM)**||
|<br>kW|<br>A|A|A|A|
|0.25|0.8|4|-|2|
|0.37|1.1|4|-|2|
|0.55|1.5|6|-|4|
|0.75|2.0|6|-|4|
|1.1|3 0|10|-|6|
|1.5|3.6|16|-|0 1|
|2.2|5.0|16|-|0 1|
|3.0|6.5|20|-|6 1|
|4.0|8.4|20|-|6 1|
|5.5|11.0|25|20M25|2 20|
|7.5|15.0|40|32M40|25|
|11.0|20.0|50|32M50|32|
|15.0|27.0|63|32M63|40|
|18.5|33.0|80|63M80|50|
|22.0|38.0|80|63M80|50|
|30.0|54.0|100|63M100|80|
|37.0|66.0|125|100M125|80|
|45.0|79.0|160|100M160|100|
|55.0|98.0|160|100M160|100|
|75.0|135.0|250|200M250|160|
|90.0|155.0|250|200M250|160|
|110.0|185.0|315|200M315|200|
|132.0|220.0|355|315M400|250|
|150.0|250.0|355|315M400|315|
|185.0|310.0|450|400M500|355|
|200.0|335.0|500|4 00M500|400|
|225.0|375.0|560|-|400|
|250.0|415.0|560|-|450|
|280.0|460.0|630|-|500|
|335.0|562.0|710|-|630|
|355.0|596.0|800|-|710|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**246**
**IEC & British Standard Fuses** Basen
## **CSA Type P and Type D Fuses**
## **CDS, CDN & PON Type P & D**
## **Specifications**
**Description:** CSA time-delay Type D & P fuses.
**Dimensions:** See Catalog Numbers table and Dimensions illustration.
## **Ratings:**
Volts: — 250Vac (CDN & PON)
— 600Vac (CDS)
Amps: — 10-600A
IR: — 10kA minimum
**Agency Information:** CE, CSA Certified to C22.2 No. 59.1.
## **Features and Benefits**
- Economical fuse in a variety of ratings for applications not requiring time-delay.
**Dimensions** ~~—— A B 1 p [Ty~~ © Ferrule Design—1 through 60A
## **Typical Applications**
- Lighting, heating and other circuits not subject to temporary surges and where available short-circuit current are relatively low.
## **Basic Catalog Numbers**
## **Time-Delay CSA Type “D” Fuses**
|**Catalog**<br>**Numbers**|**Volts**|**Amp**<br>**Ratings**|
|---|---|---|
|CDN|250Vac|**Ratings**<br>Below 10A use FRN-R 10, 12, 15, 20, 25, 30,|
|||Below 10A use FRNR 10, 12, 15, 20, 25, 30,<br>35, 40, 45, 50, 60, 70, 80, 90, 100|
|||110, 125, 150, 175, 200, 225, 250, 300, 350, 400,|
|||110, 125, 150, 175, 200, 225, 250, 300, 350, 400,<br>450, 500, 600|
|||Below 10A use FRS-R 10, 12, 15, 20, 25, 30,|
|||35, 40, 45, 50, 60|
|CDS|600Vac|70, 80, 90, 100, 110, 125, 150, 175, 200,|
|||225, 250, 300, 350, 400, 450, 500, 600|
~~A B~~ C ~~D or~~ F E
|CDN|250Vac<br>110, 125, 150, 175, 200, 225, 250, 300, 350, 400,<br>450, 500, 600<br>Below 10A use FRS-R 10, 12, 15, 20, 25, 30,<br>35, 40, 45, 50, 60<br>70, 80, 90, 100, 110, 125, 150, 175, 200,|250Vac<br>110, 125, 150, 175, 200, 225, 250, 300, 350, 400,<br>450, 500, 600<br>Below 10A use FRS-R 10, 12, 15, 20, 25, 30,<br>35, 40, 45, 50, 60<br>70, 80, 90, 100, 110, 125, 150, 175, 200,|250Vac<br>110, 125, 150, 175, 200, 225, 250, 300, 350, 400,<br>450, 500, 600<br>Below 10A use FRS-R 10, 12, 15, 20, 25, 30,<br>35, 40, 45, 50, 60<br>70, 80, 90, 100, 110, 125, 150, 175, 200,|F<br>110, 125, 150, 175, 200, 225, 250, 300, 350, 400,<br>~~or~~|F<br>110, 125, 150, 175, 200, 225, 250, 300, 350, 400,<br>~~or~~|F<br>110, 125, 150, 175, 200, 225, 250, 300, 350, 400,<br>~~or~~|E<br>~~or~~|||
|---|---|---|---|---|---|---|---|---|---|
|CDS|600Vac<br>70, 80, 90, 100, 110, 125, 150, 175, 200,<br>225, 250, 300, 350, 400, 450, 500, 600|||Knife Blade—70 through 600A|||E|||
|**One-Time CSA Type “P” Fuses**||||||||||
|**Catalog**<br>**Number**|**Amp**<br>**Volts**<br>**Ratings**|||||||||
|PON|250Vac<br>15, 20, 25, 30, 35, 40, 45, 50, 60|||||||||
|**Catalog Numbers**<br>**Basic Catalog**<br>**Number**<br>**Amp**<br>**A**<br>**and Volts**<br>**Ratings**<br>**Overall**<br>1-30<br>2.0 (50.8)<br>35-60<br>3.0 (76.2)<br>CDN/PON 250Vac<br>70-100<br>5.88 (149.4)<br>110-200<br>7.3 (185.4)<br>225-400<br>8.63 (219.2)<br>450-600<br>10.38 (263.7)<br>~~== ~~|||**Dimensions in(mm)**<br>**B Max**<br>**C Min**<br>**D Min**<br>**E**<br>**F**<br>**Diameter**<br>**Blade Length**<br>**Barrel Length**<br>**Blade Thickness**<br>**Blade Width**<br>0.56 (14.3)<br>—<br>—<br>—<br>—<br>0.81 (20.6)<br>—<br>—<br>—<br>—<br>—<br>1.0 (25.4)<br>—<br>0.13 (3.2)<br>0.75 (19.1)<br>—<br>1.38 (34.9)<br>4.13 (104.8)<br>0.19 (4.8)<br>1.13 (28.6)<br>—<br>1.88 (47.6)<br>4.63 (117.5)<br>0.25 (6.4)<br>1.63 (41.3)<br>—<br>2.25 (57.2)<br>5.19 (131.8)<br>0.25 (6.4)<br>2 (50.8)<br> ~~SSS~~|||||**Fuses**|**IEC & British**|
|||1-30<br>5.0 (127.0)|0.81 (20.6)|—|—|—|—|||
|||35-60<br>5.5 (139.7)|1.06 (27.0)|—|—|—|—|||
|CDS 600Vac||70-100<br>7.88 (200.2)<br>110-200<br>9.63 (244.6)|—<br>—|1.0 (25.4)<br>1.38 (34.9)|—<br>6.13 (115.6)|0.13 (3.2)<br>0.19 (4.8)|0.75 (19.1)<br>1.13 (28.6)|||
|||225-400<br>11.63 (295.4)|—|1.88 (47.6)|7.13 (118.1)|0.25 (6.4)|1.63 (41.3)|||
|||450-600<br>13.38 (339.9)|—|2.25 (57.2)|8.19 (208.0)|0.25 (6.4)|2 (50.8)|||
## **To Order**
To order, specify Basic Catalog Number and amp rating. Example: CDN-30
**Data Sheet: 4126**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**247**
**IEC & British Standard Fuses**
## **Tron[™] HRC Form II Class C Fuses**
**==> picture [55 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions<br>**----- End of picture text -----**<br>
## **CGL Form II Class C**
## **Specifications**
**==> picture [496 x 440] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.22" 0.22" 0.81"<br>Description: Current-limiting HRCII-C fuses (5.56mm) (5.56mm) (20.64mm)<br>designed to withstand inrush currents on<br>typical motor start-ups while offering high (50.8mm) 2.0" 0.34" (1.59mm) 0.06"<br>current limitation in the short-circuit region. 2.80" (8.73mm) 0.94"<br>Dimensions: See Dimensions illustrations. (71.04mm) 3.31" (23.81mm)<br>(84.14mm)<br>Ratings: CGL 1-30<br>Volts: — 600Vac/250Vdc (1-30A) 0.22" 0.22" 0.81"<br>Amps: — 1-600A (5.56mm) (5.56mm) (20.64mm)<br>IR: — 200kA (40,000A DC)<br>2.0" 0.06"<br>Agency Information: CE, CSA Certified, (50.8mm) 2.80" (12.7mm) 0.50" (1.59mm) 1.06"<br>C22.2 No. 106. (71.04mm) (26.92mm)<br>3.5"<br>(88.9mm)<br>Features and Benefits CGL 35-60<br>• Close sizing to loads allows using smaller and less costly<br>switches 0.343" 0.343" 1.34"<br>• Provides a higher degree of short-circuit protection (8.71mm) (8.71mm) (34.04mm)<br>• Helps protect motors against burnout from overloads<br>Typical Applications (60.72mm) 2.393.64" " (19.05mm) 0.75" (2.29mm) 1.375"0.09"<br>• For use in circuits subject to surge currents such as those (92.47mm) 4.31" (34.93mm)<br>caused by motors, transformers and other inductive loads (109.54mm)<br>CGL 70-100<br>-<br>Catalog Numbers ( Amps)<br>CGL-1 CGL-40 CGL-175 0 .343" 0.343<br>CGL-2 CGL-45 CGL-200 (8.71mm) (8.71mm)<br>CGL-3 CGL-50 CGL-225<br>CGL-4 CGL-60 CGL-250<br>CGLCGLCGL---61015 CGLCGLCGL---809070 CGLCGLCGL---350400300 (109.22mm)(76.2mm) 3.00"4.30" (19.05mm) 0.75" (38.1mm) 1.50" (3.18mm) 0 .125"<br>5.31"<br>CGL-20 CGL-100 CGL-450 (134.87mm)<br>CGL-25 CGL-110 CGL-500 CGL 110-200<br>CGL-30 CGL-125 CGL-600 0.19"<br>CGL-35 CGL-150 0.38" 1.0" (4.76mm)<br>(9.53mm) (25.4mm)<br>1.0"<br>(25.4mm)<br>3.0" 2.38"<br>(76.2mm) (60.33mm)<br>5.25"<br>(133.35mm)<br>8.19"<br>BEC (207.96mm)<br>**----- End of picture text -----**<br>
**==> picture [241 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
CGL 225-400<br>0.41" 1.0"<br>(10.32mm) (25.4mm)<br>1.0"<br>(25.4mm) .60"<br>3.0" (15.24mm) 0.375 "<br>(76.2mm) (9.53mm)<br>imag (133.35mm) 5.25"8.19" e (76.2mm) 3.00"<br>(207.96mm)<br>CGL 450-600<br>**----- End of picture text -----**<br>
**Data Sheet: 4125**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**248**
**IEC & British Standard Fuses** ag
## **HRCI Industrial Ceramic Body Fuses**
## **CIF21 HRCI-CA**
## **Specifications**
**Description:** The HRCI-CA fuse provides both overload and short-circuit protection to HRCI requirements. Offset blades for bolt-on mounting. CIF21 fuse fits the Cooper Bussmann CAMaster fuse holder (see data sheet 4132).
**Dimensions:** See Dimensions illustration.
**Construction:** Ceramic body.
## **Ratings:**
Volts: — 600Vac/250Vdc Amps: — 1-30A
IR: — 200kA RMS Sym.
**Agency Information:** CE, CSA C22.2, No. 106-M92. **Mounting:** Bolt-on.
## **Catalog Numbers**
|**Catalog Numbers**<br>**Catalog**<br>**Numbers**|**Catalog Numbers**<br>**Amp**<br>**Ratings**|
|---|---|
|1CIF21|**Ratings**<br>1|
|1CIF21<br>3CIF21|1<br>3|
|3CIF21<br>6CIF21|3<br>6|
|6CIF21<br>10CIF21|6<br>10|
|10CIF21<br>15CIF21|10<br>15|
|15CIF21<br>20CIF21|15<br>20|
|20CIF21<br>25CIF21|20<br>25|
|25CIF21<br>30CIF21|25<br>30|
## **CIF06 HRCI-CB**
## **Specifications**
**Description:** A miniature industrial fuse that provides both short-circuit and overload protection and the CIF06 fits the 30A SAFEloc fuse holder.
**Dimensions:** See Dimensions illustration.
**Construction:** Ground ceramic body with plated end caps.
## **Ratings:**
Volts: — 600Vac/250Vdc
Amps: — 1-30A
IR: — 200kA RMS Sym.
**Agency Information:** CE, CSA C22.2 No. 106-M92 (3-30A only).
**Mounting:** Clip-in offset blades.
## **Catalog Number**
|**Catalog**<br>**Numbers**|**Amp**<br>**Ratings**|
|---|---|
|1CIF06|1|
|3CIF06|3|
|6CIF06|6|
|10CIF06|10|
|15CIF06|15|
|20CIF06|20|
|25CIF06|25|
|30CIF06|30|
## **Features and Benefits**
- Close sizing to loads allows using smaller and less costly switches
- Provides a higher degree of short-circuit protection
- Helps protect motors against burnout from overloads
## **Features and Benefits**
- Close sizing to loads allows using smaller and less costly switches
- Provides a higher degree of short-circuit protection
- Helps protect motors against burnout from overloads
## **Typical Applications**
- For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads
## **Typical Applications**
- For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads
## **Dimensions - in (mm)**
## **Dimensions - in (mm)**
~~2.15 (54.5) 2.38 (60.4) se 1.44 (35.5) 1.44 (35.5)~~ 0.19 (4.7) 0.44 (11.1) 0.54 (13.8) 0.5 (12.7) G ~~et~~ t—ie ~~;~~ | ~~(ooo~~ 0.54 (13.8) 0.03 (3.5) ~~UWL 1.75 (44.5)~~ 0.03 (0.81) 0.14 (3.5) ~~oo~~
**Data Sheet: 4128**
**Data Sheet: 4127**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**249**
**IEC & British Standard Fuses**
## **HRCI-J Fast-acting Fuses**
## **CJ HRCI-J**
## **Specifications**
**Description:** HRCI-J fast-acting fuses are industrial duty fuses with the excellent current-limiting characteristics of fast-acting HRCI-J fuses to limit damage to equipment and installations by the thermal and magnetic energy associated with a large short-circuit fault current. Overload characteristics limit cable damage due to low overload currents.
**Dimensions:** See Catalog Numbers table and Dimensions illustrations.
## **Dimensions**
**==> picture [223 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
1CJ to 60CJ A<br>B B<br>C<br>70CJ to 600CJ<br>E A<br>K F<br>J<br>H<br>C D<br>B<br>G<br>**----- End of picture text -----**<br>
**Construction:** Ceramic body fuse.
## **Ratings:**
Volts: — 600Vac (or less), 250Vdc Amps: — 1-600A
IR: — 200kA
**Agency Information:** CSA C22.2 No. 106 M92; Designed to BS 88:2, IEC 60269-2.
## **Catalog Numbers**
|**Catalog Numbers**<br>**Catalog**<br>**Numbers**|**Catalog Numbers**<br>**Amp**<br>**Ratings**|**Catalog Numbers**<br>**Dimensions- in (mm)**|**Catalog Numbers**<br>**Dimensions- in (mm)**|**Catalog Numbers**<br>**Dimensions- in (mm)**|**Catalog Numbers**<br>**Dimensions- in (mm)**|**Catalog Numbers**<br>**Dimensions- in (mm)**|**Catalog Numbers**<br>**Dimensions- in (mm)**|**Catalog Numbers**<br>**Dimensions- in (mm)**|**Catalog Numbers**<br>**Dimensions- in (mm)**|**Catalog Numbers**<br>**Dimensions- in (mm)**|**Catalog Numbers**<br>**Dimensions- in (mm)**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|||**A**|**B**|**C**|**D**|**E**|**in (mm)**<br>**F**|**G**<br>**H**|**H**|**J**|**K**|
|1CJ<br>3CJ<br>6CJ<br>10CJ<br>15CJ<br>20CJ<br>25CJ<br>30CJ|1<br>3<br>6<br>10<br>15<br>20<br>25<br>30|2.25 (57)|0.5 (12.7)|0.81 (20.6)|—|—|—|—<br>—|—|—|—|
|35CJ<br>40CJ<br>45CJ<br>50CJ<br>60CJ|35<br>40<br>45<br>50<br>60|2.38 (60)|0.63 (16)|1.06 (27)|—|—|—|—<br>—|—|—|—|
|70CJ<br>80CJ<br>90CJ<br>100CJ|70<br>80<br>90<br>100|4.63 (117)|3.63 (92)|1.13 (28)|0.75 (19)|0.13 (3.2)|1 (25.4)|0.5 (12.7)<br>0.28 (7.1)|0.28 (7.1)|0.38 (9.5)|2.63 (67)|
|110CJ<br>125CJ<br>150CJ<br>175CJ<br>200CJ|110<br>125<br>150<br>175<br>200|5.75 (146)|4.38 (111)|1.63 (41)|1.13 (28.6)|0.19 (4.8)|1.38 (35)|0.69 (17.5)<br>0.28 (7.1)|0.28 (7.1)|0.38 (9.5)|3 (76)|
|225CJ<br>250CJ<br>300CJ<br>350CJ<br>400CJ|225<br>250<br>300<br>350<br>400|7.13 (181)|5.25 (133)|2.13 (54)|1.63 (41)|0.25 (6.3)|1.88 (47.6)|0.94 (24)<br>0.41 (10.3)<br>~~ee~~|0.41 (10.3)|0.53 (13.5)|3.38 (86)|
|450CJ<br>500CJ<br>600CJ|450<br>500<br>600<br>~~ee~~|8 (203)<br>~~ee~~|6 (152)<br>~~ee~~|2.63 (66)<br>~~ee~~|2 (51)<br>~~ee~~|0.38 (9.5)<br>~~ee~~|2.13 (54)<br>~~ee~~|1 (25.4)<br>0.53 (13.5)<br>~~ee~~<br>~~ee~~|0.53 (13.5)<br>~~ee~~|0.69 (17.5)<br>~~ee~~|3.75 (96)|
**Data Sheet: 4129**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**250**
**IEC & British Standard Fuses** ee
## eee eee eee ee eee ee ee eee eee eee **HRCI - Miscellaneous Type K Fuses**
## **CIH, CIK & CIL HRCI-MISC**
## **Specifications**
**Description:** HRI fuses provide both overload and short-circuit protection, featuring offset blades for bolt down mounting.
**Dimensions:** See Catalog Numbers table and Dimensions illustration.
**Construction:** Ceramic body. **Ratings:** Volts: — 600V Amps: — 1-100A IR: — 200kA@600V
**Agency Information:** CE, CSA C22.2 No. 106 M92.
**Dimensions**
**==> picture [544 x 442] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|F|J|
|K|D|A|G|E|
|7a|
|B|
|G|
|L|H|
|C|
|(The CIL14 has a rejection hole, not a slot as shown above.)|
|Catalog Numbers|
|Catalog|Amp|Dimensions - in (mm)|
|Numbers|Ratings|A Max|B Max|C Max|D Nom|E Nom|F Nom|G Nom|H Nom|J Max|K Nom|L Max|
|1CIH07|1|2.25 (57)|0.94 (24)|3.38 (86)|0.38 (9.2)|0.04 (1.0)|2.88 (73)|0.21 (5.2)|0.31 (8)|1 (25.4)|0.10 (2.6)|2.38 (60)|
|3CIH07|————————|3|
|6CIH07|6|
|10CIH07|—|10|
|2.25 (57)|0.94 (24)|3.38 (86)|0.38 (9.2)|0.04 (1.0)|2.88 (73)|0.21 (5.2)|0.31 (8)|1 (25.4)|0.10 (2.6)|2.38 (60)|
|15CIH07|15|
|20CIH07|20|
|25CIH07|25|
|30CIH07||=e|30|
|35CIK07|35|2.28 (58)|1.06 (27)|3.56 (91)|0.5 (12.7)|0.05 (1.2)|2.88 (73)|0.21 (5.2)|0.41 (10.5)|1.09 (28)|0.13 (3.2)|2.38 (61)|
|40CIK07|40|2.28 (58)|1.06 (27)|3.56 (91)|0.5 (12.7)|0.05 (1.2)|2.88 (73)|0.21 (5.2)|0.41 (10.5)|1.09 (28)|0.13 (3.2)|2.38 (61)|
|50CIK07|50|
|60CIK07|60|
|80CIL14|=|80|2.75 (70)|1.44 (37)|4.38 (111)|0.75 (19)|0.09 (2.5)|3.69 (94)|0.34 (8.7)|0.41 (10.5)|1.5 (38.5)|—|2.91 (74)|
|90CIL14|90|2.75 (70)|1.44 (37)|4.38 (111)|0.75 (19)|0.09 (2.5)|3.69 (94)|0.34 (8.7)|0.41 (10.5)|1.5 (38.5)|—|2.91 (74)|
|100CIL14|—|100||i|||tet|tt|ft|
|||||cE|mE|
|Recommended Fuse Holders|
|Fuse|Fuse Holder|
|1-30A|CM30CF|
|—t|35-60A|CM60CF|
|Data Sheet: 4130|
|For product data sheets, visit www.cooperbussmann.com/DatasheetsEle|
**----- End of picture text -----**<br>
**251**
**IEC & British Standard Fuses**
## **HRC Form II Current-limiting Fuses**
## **HRC Form II**
## **Dimensions**
**==> picture [527 x 607] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|F|J|
|Specifications|G|A|D|E|
|Description:|HRC|Form II|B|H07C|
|(Offset Blades)|
|current-limiting fuses.|H|
|per|C|
|Dimensions:|See Catalog|
|Numbers table and Dimensions|F|J|
|illustrations.|A|E|
|Construction:|Ceramic body.|G|D|K07C/K07CR/|
|B|L14C/M14C|
|Ratings:|(Offset Blades)|
|th|H|
|Volts:|— 600Vac (or less)|fle|C|
|— 250Vdc|
|Amps:|— 2-600A|C|B|
|A|
|IR:|— 200kA RMS Sym.|G|Hea|H|D|tik|L09C/M09C/P09C|
|Agency Information:|CE, CSA C22.2 No.106M1992;|(Center Blades)|
|BS 88:2, IEC 60269:2.|
|F|E|
|1|Te|©|
|Typical Applications|
|•|Used to protect motor control circuits, together with|
|contactors and overload protection relays to provide Type 2|K|AF|K|B|
|coordination - per IEC 60947-4.|G|D|P11C/R11C|
|(Center Blades)|
|H|E|
|Laie|C|
|Catalog Numbers|
|Catalog|Amp|Dimensions - in (mm)|
|Numbers|Ratings|A|B|C|D|E|F|G|H|J|K|CSA Category|
|2H07C|2|1.38 (35)|0.56 (14)|3.38 (85)|0.38 (9)|0.06 (1.2)|2.88 (73)|0.22 (5.6)|0.31 (8)|0.56 (14)|—|HRCII-C|
|4H07C|4|
|6H07C|6|
|10H07C|10|1.38 (35)|0.56 (14)|3.38 (85)|0.38 (9)|0.56 (14)|—|
|15H07C|15|
|20H07C|20|HRCII-C|
|25H07C|25|0.06 (1.2)|2.88 (73)|0.22 (5.6)|0.31 (8)|
|30H07C|30|
|40K07C|40|2.19 (56)|0.88 (22)|3.44 (87)|0.5 (13)|0.06 (1.2)|2.88 (73)|0.22 (5.6)|0.31 (8)|0.88 (22)|—|HRCII-C|
|50K07C|50|3.44 (87)|—|
|60K07C|60|2.19 (56)|0.88 (22)|0.5 (13)|0.88 (22)|
|80K07CR|80|2.19 (56)|0.88 (22)|3.75 (95)|3.75 (95)|0.5 (13)|0.06 (1.2)|2.88 (73)|0.22 (5.6)|0.31 (8)|0.88 (22)|—|—|HRCII-MISC|HRCII-MISC|
|100K07CR|tH|100|THE|
|80L14C|80|2.38 (60)|2.38 (60)|0.88 (21.4)|0.88 (21.4)|4.38 (111)|0.56 (14.3)|0.56 (14.3)|0.13 (3.2)|0.13 (3.2)|3.69 (94)|0.34 (8.7)|0.44 (11)|1 (25.4)|1 (25.4)|—|—|HRCII|HRCII-C|-C|
|100L14C|100|
|125M14C|||125|2.56 (65)|1.5 (38)|4.38 (111)4.38 (111)|Ff|0.75 (19)|0.09 (2.4)|3.69 (94)3.69 (94)|0.34 (8.7)|0.44 (11)|PF|—|tT|—|HRCII-MISC|
|150M14C|150|2.56 (65)|1.5 (38)|0.75 (19)|0.09 (2.4)|0.44 (11)|—|—|
|200M14C|See|200|||HRCII-MISC|
|80L09C|80|2.38 (60)|2.38 (60)|0.88 (21.4)|0.88 (21.4)|5 (127)|5 (127)|0.56 (14)|0.56 (14)|0.13 (3.2)|4.38 (111)|0.34 (8.7)|0.44 (11)|—|—|—|—|HRCII-MISC|
|100L09C125M09C|ee|100125|2.56 (65)|ee|1.5 (38)|5.38 (136)|ee|0.75 (19)|0.13 0.13 (3.2)(3.2)|4.38 (111)|0.34 (8.7)|0.34 (8.7)||eo|0.56 (14)|||—|—|HRCII-C|
|150M09C|150|2.56 (65)|1.5 (38)|0.75 (19)|0.56 (14)|—|—|HRCII-C|
|200M09C|200|4.38 (111)|
|250P09C|250|3.06 (178)|2.31 (59)|5.38 5.38 (136)(136)|1 (25.4)|0.19 (4.8)|4.38 (111)|0.34 (8.7)|0.5 (13)|—|—|HRCII-MISC|
|300P09C|300|0.19 (4.8)|0.5 (13)|—|—|HRCII-MISC|
|350P09C|350|
|400P09C|aH|400|Tr|
|250P11C|250|3.06 (178)|3.06 (178)|2.31 (59)|2.31 (59)|8.25 (210)|1 (25.4)|0.19 (5)|5.25 (133)|0.41 (10)|0.63 (16)|—|1 (25)|HRCII-C|
|300P11C|300|1 (25.4)|—|
|0.19 (5)|1 (25)|
|350P11C|350|
|400P11C|S||400|8.25 (210)|_|5.25 (133)|0.41 (10)|aie|0.63 (16)|HRCII-C|
|450R11C|450|3.19 (81)|2.88 (73)|8.25 (210)|1 (25.4)|0.25 (6.3)|5.25 (133)|0.41 (10)|0.63 (16)|—|1 (25)|HRCII-C|
|500R11C|500|3.19 (81)|2.88 (73)|0.25 (6.3)|—|1 (25)|
|600R11C|=e|600|rE|
|Be|EH|LL|EH|
**----- End of picture text -----**<br>
**Data Sheet: 4131**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**252**
**IEC & British Standard Fuses**
## **BS 88 British Standard Low Voltage Fuses**
## **SSD, NSD, ESD BS 88 Part 1**
## **Specifications**
**Description:** The NSD and ESD are low voltage fuses complying with general purpose gG characteristics.
**Construction:** Ceramic body.
## **Ratings:**
Volts: — 240-550Vac (See Catalog Numbers table)
Amps: — 2-63A (See Catalog Numbers table)
- 20M25-63M100A Motor Starter ratings (See Catalog Numbers table)
- IR: — 33kA (SSD)
- 80kA (NSD, ESD)
**Agency Information:** CE, Meets the requirements of BS 88 Part 1 and IEC 60269-1.
**Mounting:** Offset blades.
## **STD, NITD, AAO, BAO, OSD, CEO, DEO BS 88 Part 1**
## **Specifications**
**Description:** The STD to DEO types are low voltage fuses complying with general purpose gG characteristics.
**Construction:** Ceramic body.
## **Ratings:**
- Volts: — 240-550Vac (See Catalog Numbers table)
- Amps: — 2-200A (See Catalog Numbers table)
- 20M25-200M315A Motor Starter ratings (See Catalog Numbers table)
- IR: — 33kA (STD)
- 80kA (NITD, AAO, BAO, CEO, DEO)
**Agency Information:** CE, Meets the requirements of BS 88 Part 1 and IEC 60269-1.
**Basic Catalog Numbers Mounting:** Offset bolted blades. **Basic Max AC CatalogNumbers** SSD 2, 4, 6, 10, 16, 20, 25, 32 **AmpRatings RatinVoltage** 240 **gs BS 88Ref.** E1 • **Typical Applications** The STD type are used in 240V street lighting cut-outs NSD 2, 4, 6, 10, 16, 20, 25, 32, 550 F1 • NITD to DEO types used for industrial and general purpose 20M25*, 20M32*, 20M36*, 32M36*, 32M40*,32M50*, 32M63* 415415 F1F1 applications ESD 2, 4, 6, 10, 16, 25, 3240, 50, 63, 63M80, 63M100* 415550 F2F2 **Basic CataloBasic g Numbers Max AC** *“M” indicates motor starter ratings. **Catalog Amp Voltage BS 88 Numbers Ratings Ratings Ref. To Order** STD 2, 4, 6, 10, 16, 20, 25, 32 240 — NITD 2, 4, 6, 10, 16, 20, 25, 32 550 — To order, specify Basic Catalog Number and amp rating. Example: SSD-20 20M25*, 20M32*, 32M40*, 32M50*, 32M63* 415 — AAO 2, 4, 6, 10, 16, 20, 25, 32, 32M40*, 32M50*, 32M63* 550 — **Recommended Fuse Holders** BAO 40, 50, 63, 63M80*, 63M100* 550 A3 CEO 32, 40, 50, 63, 80, 100 550 A4 **Basic Fuse Holder Catalog** 100M125*, 100M160*, 100M200* 415 A4 **Catalog Numbers Numbers** DEO 125, 160, 200, 200M250*, 200M315* 415 — NSD 32NNSF OSD 80, 100 550 — ~~as~~ ESD 63ENSF ~~=~~ 100M125*, 100M160* 415 — *“M” indicates motor starter ratings. **To Order** To order, specify Basic Catalog Number and amp rating. Example: BAO-16 **Recommended Fuse Blocks & Holders Basic Fuse Block/Holder Catalog Numbers Catalog Numbers** NITD CM32FC AAO CM32F BAO CM63F OSD CM100F CEO BH-0111 **Data Sheets 4123 (STD), 4106 (NITD), 4109 (AAO), 4112 Data Sheets 4105 (SSD), 4100 (NSD) and 4101 (ESD) (BAO), 4107 (OSD), 4115 (CEO) and 4117 (DEO)** For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**253**
**IEC & British Standard Fuses**
## **BS 88 British Standard Low Voltage Fuses**
## **AC, AD, BC, BD, CD, DD, ED, EFS BS 88**
## **EF, FF, FG, GF, GG, GH BS 88**
## **Specifications**
**Description:** Low voltage fuses that comply with general purpose gG characteristics and available up to 400A with two hole mount and up to 1250A with four hole mount.
## **Specifications**
**Description:** Low voltage fuses complying with general purpose gG characteristics and available up to 400A with two hole mount and up to 1250A with four hole mount. **Construction:** Ceramic body.
**Construction:** Ceramic body. **Ratings:**
Volts: — 415/550Vac, 250Vdc (See Catalog Numbers table)
## **Ratings:**
Volts: — 415/550Vac, 250/400Vdc (See Catalog Numbers table for details) Amps: — 355-1250
Amps: — 2-400A (See Catalog Numbers table)
- 63M80-400M500A Motor Starter ratings (See Catalog Numbers table)
IR: — See Catalog Numbers table **Agency Information:** CE, Meets the requirements of BS 88 Parts 1 and 2 and IEC269-1.
IR: — See Catalog Numbers table
**Agency Information:** CE, Meets the requirements of BS 88 Parts 1 and 2 and IEC 60269-1.
**Mounting:** Center bolted blades, four-hole mount.
**Mounting:** Center bolted blades, two-hole mount.
## **Basic Catalog Numbers**
## **Basic Catalog Numbers**
|**Basic Catalog Numbers**|**Basic Catalog Numbers**|||**Basic**<br>**Interrupting**<br>**Max Voltage**|
|---|---|---|---|---|
|**Basic**<br>**Catalog**<br>**Numbers**<br>AC<br>AD<br>BC<br>BD|**Interrupting**<br>**Max Voltage**<br>**Amp**<br>**Ratings**<br>**Ratings**<br>**Ratings**<br>**AC**<br>**DC**<br>**AC**<br>**DC**<br>2, 4, 6, 10, 16, 20, 25, 32<br>80kA<br>40kA<br>550<br>250<br>2, 4, 6, 10, 16, 20, 25, 32<br>80kA<br>40kA<br>550<br>250<br>40, 50, 63<br>80kA<br>40kA<br>550<br>250<br>63M80*, 63M100*<br>80kA<br>—<br>550<br>—<br>40, 50, 63<br>80kA<br>40kA<br>550<br>250<br>~~r~~~~**e**~~<br>~~c~~<br>~~———~~<br>~~ee ee ee~~<br>~~ee~~<br>~~ee eee~~<br>~~GG~~|**BS 88**<br>**Ref.**<br>—<br>—<br>—<br>—<br>—||**Catalog**<br>**Amp**<br>**Ratings**<br>**Ratings**<br>**BS 88**<br>**Numbers**<br>**Ratings**<br>**AC**<br>**DC**<br>**AC**<br>**DC**<br>**Ref.**<br>EF<br>355, 400<br>80kA<br>—<br>415<br>—<br>C1<br>400M500*<br>80kA<br>—<br>550<br>—<br>—<br>FF<br>450, 500, 560, 630<br>80kA<br>40kA<br>550<br>400<br>C2<br>FG<br>450, 500, 560, 630<br>80kA<br>40kA<br>550<br>400<br>—<br>GF<br>710, 800<br>80kA<br>40kA<br>550<br>250<br>C3<br>GG<br>710, 800<br>80kA<br>40kA<br>550<br>250<br>—|
|CD<br>DD<br>ED<br>EFS|1000, 1250<br>80kA<br>—<br>550<br>—<br>—<br>GH<br>710, 800, 1000, 1250<br>80kA<br>—<br>550<br>—<br>—<br>*“M” indicates motor starter ratings.*“M” indicates motor starter ratings.<br>**To Order**<br>To order, specify Basic Catalog Number and amp rating. Example: FG-450<br>80, 100, 100M125*, 100M160*,<br>80kA<br>—<br>415<br>—<br>B1<br>100M200*, 100M200*<br>125, 160, 200,<br>80kA<br>—<br>415<br>—<br>B2<br>200M250*, 200M315*<br>250, 315, 355, 400, 315M400*<br>80kA<br>—<br>415<br>—<br>B3<br>400M500*<br>80kA<br>—<br>550<br>—<br>B4<br>125, 160, 200, 250, 315<br>80kA<br>415<br>—<br>—<br>~~eee~~<br>~~ee~~<br>~~ee eee~~<br>~~ee~~<br>~~ee eee~~||||
To order, specify Basic Catalog Number and amp rating. Example: FG-450
*“M” indicates motor starter ratings.
## **To Order**
To order, specify Basic Catalog Number and amp rating. Example: BC-40
## **Recommended Fuse Blocks & Holder**
|**Basic Fuse**|**Block/Holder**|
|---|---|
|**Catalog Numbers**|**Catalog Numbers**|
|AC|BH-0111 Modular fuse block|
|AD|200DF Fuse holder|
|BC|BH-0111 Modular fuse block|
|BD|200DF-L|
|CD|200DF-L|
|DD|200DF-L|
|ED|BH-1131 Modular fuse block|
**Data Sheets 4110 (AC), 4111 (AD), 4113 (BC), 4114 (BD), 4116 (CD), 4118 (DD), 4119 (ED) and 4121 (EFS)**
**Data Sheets 4120 (EF), 4102 (FF), 4122 (FG), 4103 (GF), 4104 (GG) and 4108 (GH)**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**254**
**IEC & British Standard Fuses** nn:
## **DIN Style Type D and Neozed Low Voltage Fuses**
**D16, D27, D33, D125 Type D Specifications Description:** DIN style Type D low voltage fuses. **Dimensions:** See Catalog Numbers table and Dimensions illustrations. **Construction:** Ceramic body. **Ratings:** 35
**Ratings:**
Volts: — 500Vac
Amps: — 2-100A
IR: — 100kA
**Agency Information:** CE, “D” type fuses complying with DIN 49360 Part 2 and DIN 49515, operating class gL.
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Amp**<br>**Ratings**|**Dimension**<br>**“D”(mm)**|**Color**<br>**Code**|**Figure**<br>**Number**|
|---|---|---|---|---|
|2D16<br>4D16<br>6D16<br>10D16<br>16D16<br>20D16<br>25D16|2<br>4<br>6<br>10<br>16<br>20<br>25|6<br>6<br>6<br>8<br>10<br>12<br>14|Pink<br>Brown<br>Green<br>Red<br>Grey<br>Blue<br>Yellow|1|
|2D27<br>4D27<br>6D27<br>10D27<br>16D27<br>20D27<br>25D27|2<br>4<br>6<br>10<br>16<br>20<br>25|6<br>6<br>6<br>8<br>10<br>12<br>14|Pink<br>Brown<br>Green<br>Red<br>Grey<br>Blue<br>Yellow|2|
|35D33<br>50D33<br>63D33|35<br>50<br>63|16<br>18<br>20|Black<br>White<br>Copper|3|
|80D125<br>100D125|80<br>100|5<br>7|Silver<br>Red|4|
## **NZ01, NZ02 Type D0**
## **Specifications**
**Description:** Low voltage Neozed fuses suitable for use on 250Vdc systems.
**Dimensions:** See Catalog Numbers table and Dimensions illustration.
**Construction:** Ceramic body.
## **Ratings:**
Volts: — 400Vac Amps: — 2-63A
IR: — 100kA
**Agency Information:** CE **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Amp**<br>**Ratings**|**Dimension**<br>**“D” (mm)**|**Color**<br>**Code**|
|---|---|---|---|
|2NZ01|2|11|Pink|
|4NZ01|4|11|Brown|
|6NZ01|6|11|Green|
|10NZ01|10|11|Red|
|16NZ01|16|11|Grey|
|20NZ02|20|15|Grey<br>Blue|
|25NZ02|25|15|Yellow|
|35NZ02|35|15|Black|
|50NZ02|50|15|White|
|63NZ02|63|15|Copper|
## **Dimensions - mm**
**==> picture [28 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
D<br>36<br>**----- End of picture text -----**<br>
Additional Fuse links: Quick acting fuselinks in body sized D16, D27, D33 and D125 rated 2-100A. Reference number suffixed Q, i.e. 10D27Q. Voltage rating 500V. Gauge rings and keys can also be supplied.
**Dimensions - mm**
**==> picture [222 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 1 Figure 2 Figure 3 Figure 4<br>**----- End of picture text -----**<br>
**Data Sheet: 4124**
**Data Sheet: 4124**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**255**
**IEC & British Standard Fuses**
## **NH HRC Fuses**
## **___NHG___B**
**Specifications Class:** gG/gL **Description:** DIN square bodied, dual indication industrial fuses.
**Construction:** Steatite insulator, corrosionproof (aluminum) metal parts with full-contact, silver-plated copper blades.
**Sizes:** DIN 000 to 4. **Selectivity Ratio:** 1:1.6 up to 500Vac.
## **Ratings:**
Volts: — 500Vac/250Vdc — 690Vac/250Vdc Amps: — 2-1250A IR: — 120kA Frequency: — 50Hz
Operating Frequency: — 45-62Hz **Agency Information:** IEC 60269, VDE0636, DIN 43620 Part 1 to 4, VDE Mark and CE.
|**Fuse Blocks**|**Size**<br>~~oo~~|
|---|---|
|SB00-D|000-00|
|SB1-D|1*, 1|
|SB2-D|02, 2, 03, 3|
## **Dimensions - mm**
**Fuse a2 b c1 c2 D e1 e2 e3 e4 f Size a1 (max) a3 a4 (nom) (± 8) (nom) (nom) (max) (max) (max) (nom) (max)** 000 ~~Ga~~ 78.5 ± 1.5 54 ~~GO~~ 45 ± 1.5 49 ± 1.5 15 35 10 2 ± 0.5 41 21 16 6 8 00 ~~a~~ 78.5 ± 1.5 ~~GG~~ 54 45 ± 1.5 49 ± 1.5 15 35 11 7.0 ± 0.5 ~~OO~~ 48 30 25 ~~|~~ 6 15 0 ~~eG~~ 125 ± 2.5 68 ~~|~~ 62 +3/-1.5 68 +1.5/-3 15 35 11 ~~GO~~ 2.5 ± 0.5 48 30 25 6 15 01 ~~a~~ 135 ± 2.5 ~~GG~~ 75 62 ± 2.5 68 ± 2.5 15 40 11 2.5 ± 0.5 48 30 25 6 15 1 ~~eG~~ 135 ± 2.5 75 ~~|~~ 62 ± 2.5 68 ± 2.5 20 40 11 ~~GO~~ 2.5 ± 0.5 53 52 25 6 15 02 ~~a~~ 150 ± 2.5 ~~GG~~ 75 62 ± 2.5 68 ± 2.5 20 48 11 2.5 ± 0.5 53 52 25 6 15 2 ~~eG~~ 150 ± 2.5 75 ~~|~~ 62 ± 2.5 68 ± 2.5 25 48 11 ~~GO~~ 2.5 ± 0.5 61 60 25 6 15 03 ~~a~~ 150 ± 3 ~~GG~~ 75 62 ± 2.5 68 ± 2.5 25 60 11 2.5 ± 0.5 61 60 25 6 15 3 ~~eG~~ 150 ± 3 75 ~~|~~ 62 ± 2.5 68 ± 2.5 32 60 11 ~~GO~~ 3.0 ± 0.5 75 70 25 6 18 4 200 84 80 90 50 85 11 3 120 87 — 8 30
**Data Sheet 4173**
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**256**
**IEC & British Standard Fuses**
## **NH HRC Fuses**
|||||Rated|gG/gL Dual Indicator||
|---|---|---|---|---|---|---|
|||||Current|Voltage Conducting|Carton|
|500Vac /2|250Vdc||Size|(Amps)|MetalGrippingLugs|Quantity|
|||||2|2NHG000B|3|
|||||4|4NHG000B|3|
|||||6|6NHG000B|3|
|||||10|10NHG000B|3|
|||||16|16NHG000B|3|
|||||20|20NHG000B|3|
|||||25|25NHG000B|3|
||||000|32|32NHG000B|3|
|||||35|35NHG000B|3|
|||||40|40NHG000B|3|
|||||50|50NHG000B|3|
|||||63|63NHG000B|3|
|||||80|80NHG000B|3|
|||||100|100NHG000B|3|
||||00|125|125NHG00B|3|
|||||160|160NHG00B|3|
|||||10|10NHG0B|3|
|||||16|16NHG0B|3|
|||||20|20NHG0B|3|
|||||25|25NHG0B|3|
|||||32|32NHG0B|3|
|||||35|35NHG0B|3|
||||0|40|40NHG0B|3|
|||||50|50NHG0B|3|
|||||63|63NHG0B|3|
|||||80|80NHG0B|3|
|||||100|100NHG0B|3|
|||||125|125NHG0B|3|
|||||160|160NHG0B|3|
|||||10|10NHG01B|3|
|||||16|16NHG01B|3|
||pels<br>‘T60A,|||20<br>20NHG01B<br>3<br>25<br>25NHG01B<br>3<br>32<br>32NHG01B<br>3<br>~~a~~<br>~~ee~~|||
||ie|||35|35NHG01B|3|
||=||01|40<br>40NHG01B<br>3<br>50<br>50NHG01B<br>3<br>63<br>63NHG01B<br>3<br>~~OO~~|||
|||||80|80NHG01B|3|
|||||100|100NHG01B|3|
|||||125|125NHG01B|3|
|||||160|160NHG01B|3|
|||||200|200NHG1B|3|
||||1|224|224NHG1B|3|
|||||250|250NHG1B|3|
|||||35|35NHG02B|3|
|||||40|40NHG02B|3|
||||02|50<br>63<br>80<br>100<br>125|50NHG02B<br>63NHG02B<br>80NHG02B<br>100NHG02B<br>125NHG02B|3<br>3<br>3<br>3<br>3|
|||||160|160NHG02B|3|
|||||200|200NHG02B|3|
|||||224|224NHG02B|3|
|||||250|250NHG02B|3|
|||||315|315NHG2B|3|
||||2|355|355NHG2B|3|
||os|400<br>400NHG2B<br>3<br>250<br>250NHG03B<br>3<br>315<br>315NHG03B<br>3<br>~~ee~~|||||
||=||03|355<br>355NHG03B<br>3<br>400<br>400NHG03B<br>3<br>~~oo~~|||
||||3|500|500NHG3B|3|
|||||630|630NHG3B|3|
|||||500|500NHG4G|1|
||||4|630|630NHG4G|1|
|||Single Indicator||800|800NHG4G|1|
|||Slotted End||1000|1000NHG4G|1|
||||Tags|1250|1250NHG4G|1|
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**257**
**IEC & British Standard Fuses**
## **NH HRC Fuses**
||||Rated|gG/gL Dual Indicator|||
|---|---|---|---|---|---|---|
||||Current|Voltage Conducting|Carton||
|690Vac /2|250Vdc|Size|(Amps)|MetalGrippingLugs|Quantity||
||||2|2NHG000B-690|3||
||||4|4NHG000B-690|3||
||||6|6NHG000B-690|3||
||||10|10NHG000B-690|3||
|||000|16|16NHG000B-690|3||
||ng&<br>a te<br>=||20<br>20NHG000B-690<br>3<br>25<br>25NHG000B-690<br>3<br>32<br>32NHG000B-690<br>3<br>35<br>35NHG000B-690<br>3<br>~~OO~~<br>~~CS~~||||
||||40|40NHG000B-690|3||
||||50|50NHG00B-690|3||
|||00|63|63NHG00B-690|3||
||||80|80NHG00B-690|3||
||||100|100NHG00B-690|3||
||||6|6NHG0B-690|3||
||||10|10NHG0B-690|3||
||||16|16NHG0B-690|3||
||||20|20NHG0B-690|3||
||||25|25NHG0B-690|3||
|||0|32|32NHG0B-690|3||
||mal<br>20a,<br>ae Bee||35<br>40<br>50<br>63|35NHG0B-690<br>40NHG0B-690<br>50NHG0B-690<br>63NHG0B-690|3<br>3<br>3<br>3||
||||80|80NHG0B-690|3||
||||100|100NHG0B-690|3||
||||50|50NHG1B-690|3||
||||63|63NHG1B-690|3||
||||80|80NHG1B-690|3||
|||1|100|100NHG1B-690|3||
||||125|125NHG1B-690|3||
||||160|160NHG1B-690|3||
||||200|200NHG1B-690|3||
||||63|63NHG2B-690|3||
||||80|80NHG2B-690|3||
||||100|100NHG2B-690|3||
||||125|125NHG2B-690|3||
|||2|160|160NHG2B-690|3||
||||200<br>~~a~~|200NHG2B-690<br>~~a~~|3<br>~~a~~|~~a~~|
||Sry||224|224NHG2B-690|3||
||400A,=<br>Ge|250<br>250NHG2B-690<br>3<br>315<br>315NHG2B-690<br>3<br>250<br>250NHG3B-690<br>3<br>~~TO~~<br>~~i——«_~~ i~~_ iS~~<br>~~NO~~<br>~~or,~~|||||
||||315|315NHG3B-690|3||
|||3|355|355NHG3B-690|3||
||||400|400NHG3B-690|3||
||||425|425NHG3B-690|3||
||||500|500NHG3B-690|3||
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**258**
**IEC & British Standard Fuses**
## **NH Fuse Bases**
**SB*-D, SB*-S Up to 690V / 160 - 1250A Sizes 00, 0, 1, 2, 3, 4**
Description: NH fuse bases with thermoplastic bodies. DIN-Rail and screw mounting (siz e 4 screw fix). Range of protection accesories for live parts in order to obtain IP20 protection standard.
## Ratings:
- Volts: up to 690Vac
- Amps: 2 to 1250A
Applications: Protection of industrial circuits and electrical apparatus
Standards and Approvals: IEC 60269, DIN 43620
## **Part Numbers**
|Size<br>~~fle~~|Poles<br>~~fle~~|Current<br>(Amps)<br>~~fle~~|Part Numbers<br>~~fle~~<br>~~a~~|Carton<br>Quantity<br>~~fle~~<br>~~|.~~|Compatible<br>Fuse Size<br>~~fle~~<br>~~|.~~|
|---|---|---|---|---|---|
||||DIN Screw<br>~~fle~~<br>~~a~~|||
|00|1|160A<br>~~P|~~|SB00-D<br>~~a~~|3<br>~~|.~~|000 & 00<br>~~|.~~|
||3<br>~~P|~~||TB00-D<br>TB00-D-IP20<br>~~ff~~|1<br>~~ff~~||
|0<br>~~|~~|1<br>~~P|~~<br>~~||~~|160A<br>~~P|~~<br>~~|~~|SB0-D<br>~~ff~~<br>~~eee~~|3<br>~~ff~~<br>~~eee~~|0<br>~~eee~~|
||3<br>~~||~~||TB0-D<br>~~eee~~|1<br>~~eee~~||
|1<br>~~|~~<br>~~|~~|1<br>~~| |~~<br>~~||~~|250A<br>~~|~~<br>~~|~~|SB1-D<br>~~eee ~~<br>~~eee~~|3<br> ~~eee~~<br>~~eee~~<br>~~ee~~|01 & 1<br>~~eee~~|
||3<br>~~||~~||TB1-D<br>~~eee~~|1<br>~~eee~~<br>~~ee~~||
|2<br>~~|~~<br>~~|~~|1<br>~~| |~~<br>~~||~~|400A<br>~~|~~<br>~~|~~|SB2-D<br>~~eee~~<br>~~ee~~|3<br>~~eee~~<br>~~ee~~<br>~~eee~~|02 & 2<br>~~eee~~|
||3<br>~~||~~||TB2-D<br>~~ee~~|1<br>~~eee~~||
|3<br>~~|~~<br>~~AP~~|1<br>~~| |~~|630A<br>~~|~~<br>~~AP~~|SB3-D<br>~~ee ~~|3<br> ~~eee~~|03 & 3<br>~~eee~~<br>~~AP~~|
||3<br>~~AP~~||TB3-D<br>~~AP~~|1<br>~~AP~~||
|4<br>~~AP~~|1<br>~~AP~~|1250A<br>~~AP~~|SB4-S (Screw<br>Connection only)<br>~~AP~~|3<br>~~AP~~|4<br>~~AP~~|
## **Neutral**
|**Neutral**||||
|---|---|---|---|
|Size|Current<br>(Amps)|Part Ref|Carton<br>Quantity|
|NH00|160|SL00|3|
|NH0|160|SL0||
|NH1|250|SL1||
|NH2|400|SL2||
|NH3|630|SL3||
|NH4|1000|SL4||
## **Fuse extraction handle**
|Size|Part Ref|Carton<br>Quantity|
|---|---|---|
|C00-3|FEH|1|
## **Protection accessories**
|Size|Current<br>(Amps)|Separation Partition<br>4|Separation Partition<br>4|Fuse Casing<br>5|Fuse Casing<br>5|Terminal Cover<br>1|Terminal Cover<br>1|Separator<br>3|Separator<br>3|
|---|---|---|---|---|---|---|---|---|---|
|||Part<br>Ref|Carton<br>Quantity|Part<br>Ref|Carton<br>Quantity|Part<br>Ref|Carton<br>Quantity|Part<br>Ref|Carton<br>Quantity|
|NH00*<br>NH0<br>NH1<br>NH2<br>NH3|160A<br>160A<br>250A<br>400A<br>630A|SP00*<br>SP0<br>SP1-2<br>SP1-2<br>SP3|2<br>2<br>2<br>2<br>2|FC00*<br>FC0<br>FC1-2<br>FC1-2<br>FC3|3<br>3<br>3<br>3<br>3|CS00*<br>CS0<br>CS1<br>CS2<br>CS3|6<br>6<br>6<br>6<br>6|BC00*<br>BC0<br>BC1-2<br>BC1-2<br>BC3|2<br>2<br>2<br>2<br>2|
* For single pole only
## **IP Protection Kits**
## **Microswitch**
|Part Reference|Description||Part Ref<br>Carton Quantity||
|---|---|---|---|---|
|TB00-D-IP20|Complete triplepole fuse base IP20 rated||||
|FPK0-3P<br>FPK1-3P|IP20 kit for TB0-D fuse base<br>IP20 kit for TB1-D fuse base||BVL-50<br>1<br>Microswitch suitable for the following NH Fuse links:<br>- 400 Volts gG/gL||
|FPK2-3P|IP20 kit for TB2-D fuse base||- 500 Volts gG/gL and aM||
|FPK3-3P|IP20 kit for TB3-D fuse base||- 690 Volts gG/gL and aM||
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**259**
**IEC & British Standard Fuses**
## **Class gG/gL IEC 60269 Industrial Ferrule Fuses**
## 8 x 31mm: 400Vac, 0.5 - 25A
## 10 x 38mm: 500Vac, 0.5 - 32A
## 14 x 51mm: 400Vac - 500Vac - 690Vac, 1 - 50A
## 22 x 58mm: 400Vac - 500Vac - 690Vac, 2 - 125A
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**260**
**IEC & British Standard Fuses**
## **Class aM IEC Industrial Ferrule Fuses - Class aM IEC 60269**
## 8 x 31mm: 400Vac, 1 - 8A
10 x 38mm: 400Vac - 550Vac, 0.16 - 25A cormOMO-16 | **R** 0.16at **e** d | Rate **e** d See
## 14 x 51mm: 690Vac - 500Vac, 0.25 - 50A
## 22 x 58mm: 400Vac - 500Vac - 690Vac, 2 - 125A
Neutral Links
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**261**
**IEC & British Standard Fuses**
## **Class aM & gG/gL IEC Industrial Ferrule Fuses with Striker**
## **Class gG/gL with Striker**
|**Catalog Number**<br>**With Striker**|**Amp**<br>**Rating**|**Watts Loss**<br>**(W)**|**Voltage**<br>**(AC)**|**Interrupting**<br>**Rating (kA)**|
|---|---|---|---|---|
|C14G2S|2|0.24|500|120|
|C14G4S<br>C14G6S|4|0.45|||
|C14G6S|6|0.42|||
|C14G8S|8|0.70|||
|C14G10S|10|0.53|||
|C14G12S|12|0.88|~~500~~|~~120~~|
|C14G16S|16|1.16|~~500~~|~~120~~|
|C14G20S|20|1.23|||
|C14G25S|25<br>~~ee~~|1.46<br>~~|~~|||
|C14G32S|32<br>~~ee~~|2.04<br>~~|~~|||
|C14G40S|40<br>~~ee~~<br>~~rs~~|3.34<br>~~|~~<br>~~rs~~|||
|C14G50S|50<br>~~rs~~<br>~~a|~~|3.04<br>~~rs~~<br>~~|~~|400||
|**Catalog Number**<br>**With Striker**|**Amp**<br>**Rating**<br>~~a |~~|**Watts Loss**<br>**(W)**<br>~~|~~|**Voltage**<br>**(AC)**|**Interrupting**<br>**Rating (kA)**|
|C22G4S|4|0.48|690|80|
|C22G6S|6|0.47|||
|C22G8S|8|0.73|||
|C22G10S|10|0.74|||
|C22G12S|12|0.83|||
|C22G16S|16<br>~~ee~~|1.21<br>~~|~~|~~690~~|~~80~~|
|C22G20S|20<br>~~ee~~|1.29<br>~~|~~|~~690~~|~~80~~|
|C22G25S|25<br>~~ee~~<br>~~se~~|1.53<br>~~|~~<br>~~se~~|||
|C22G32S|32<br>~~se~~|2.13<br>~~se~~|||
|C22G40S|40<br>~~se~~|3.40<br>~~se~~|||
|C22G50S|50|3.48|||
|C22G63S|63|4.46|||
|C22G80S|80|5.86|**500**|120<br>120|
|C22G100S|100|6.61|||
|C22G125S|125|8.42|400||
## **Class aM with Striker**
## **14 X 51**
## **22 X 58**
|**Catalog Number**<br>**With Striker**|**Amp**<br>**Rating**|**Watts Loss**<br>**(W)**|**Voltage**<br>**(AC)**|**Interrupting**<br>**Rating (kA)**|
|---|---|---|---|---|
|C14M1S|1|0.14|500|120|
|C14M2S|2|0.24|||
|C14M4S|4|0.45|||
|C14M6S|6|0.42|||
|C14M8S|8|0.70|||
|C14M10S|10|0.53|500|120|
|C14M12S|12<br>~~a~~<br>~~|~~|0.88<br>~~a~~<br>~~|~~|500|120|
|C14M16S|16<br>~~a~~<br>~~|~~|1.16<br>~~a~~<br>~~|~~|||
|C14M20S|20<br>~~a~~<br>~~|~~<br>~~rs~~|1.23<br>~~a~~<br>~~|~~<br>~~rs~~|||
|C14M25S|25<br>~~rs~~<br>~~ee~~|1.46<br>~~rs~~<br>~~ee~~|||
|C14M32S|32<br>~~po~~|2.04<br>~~po~~|||
|C14M40S|40<br>~~po~~<br>~~ee~~|3.34<br>~~po~~<br>~~ee~~|||
|C14M50S|50<br>~~ee~~|3.04<br>~~ee~~|400||
|**Catalog Number**<br>**With Striker**|**Amp**<br>**Rating**|**Watts Loss**<br>**(W)**|**Voltage**<br>**(AC)**|**Interrupting**<br>**Rating (kA)**|
|C22M2S|2|0.29|690|80|
|C22M4S|4|0.48|||
|C22M6S|6|0.47|||
|C22M8S|8|0.73|||
|C22M10S|10|0.74|||
|C22M12S|12|0.83|~~690~~||
|C22M16S|16|1.21|~~690~~|~~80~~|
|C22M20S|20|1.29||~~80~~|
|C22M25S|25|1.53|||
|C22M32S|32|2.13|||
|C22M40S|40|3.40|||
|C22M50S|50<br>~~ee~~|3.48<br>~~ee~~|||
|C22M63S|63<br>~~ee~~<br>~~rs~~<br>~~es~~|4.46<br>~~ee~~<br>~~rs~~<br>~~ee~~|~~500~~<br>~~ee~~||
|C22M80S|80<br>~~rs~~<br>~~es~~|5.86<br>~~rs~~<br>~~ee~~|500<br>~~500~~<br>~~ee~~|120|
|C22M100S|100<br>~~es~~<br>~~rs~~|6.61<br>~~ee~~<br>~~rs~~|~~ee~~|~~120~~|
|C22M125S|125<br>~~rs~~<br>~~|~~|8.42<br>~~rs~~<br>~~|~~|400|~~120~~|
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
**262**
**IEC & British Standard Fuses**
## **HRC Fuse Holders**
## **CAMaster**
## **Specifications Catalog Symbol:**
See table below. **Description:** The CAMaster HRC fuse holder features a unique cam-action for easy fuse removal while allowing significantly improved contact pressure between fuse carrier and base contact that enhances
electrical performance. A range of lockable safety carriers for the fuse holder (catalog reference: LSC), are available.
## **Ratings:**
Volts: — 690V
Amps: — 30-100A (See Catalog Number table for details) **Agency Information:** CE, CSA C22.2 No. 39; IEC 269 AND BS 88.
**Mounting:** 35mm DIN-Rail or single screw mounting.
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Amp**<br>**Ratings**|**Details For:**|**Fuse**<br>**Accepted**|
|---|---|---|---|
|CM20CF|30|HRCI-CA Applications|_CIF21|
|CM30CF|30|HRCII Applications|_H07C|
|CM60CF|60||_K07C|
|CM100CF|100||_K07CR|
## **Accessory Catalog Numbers for CAMaster Units**
|**Catalog**<br>**Numbers**|**Amp**<br>**Ratings**|**Details**|**Fuse Holder**<br>**Accepted**|
|---|---|---|---|
|20BS|30|Back Stud|CM20CF|
|32BS|30||CM30CF|
|60/100BS|60/100||CM60/100CF|
|GLP|All|GangingLink Kit|3-Pole|
|NI|All|660V Neon Indicator|—|
|20LSC|30|Security Carrier with Clip|CM20CF|
|30LSC|30||CM30CF|
|60/100LSC|60/100A||CM60/100CF|
## **SAFEloc**
**Specifications Catalog Symbol:**
See table below. **Description:** The SAFEloc HRC fuse holders (for use with HRCI-CB fuses) provides a positive, stressfree fuse fitting
and locks it in position to ensure safe insertion and withdrawal from the base. Base contacts are fully shrouded to help protect against electric shock. Shrouds utilize simple slide/snap action allowing access to the contact terminal screws.
## **Ratings:**
Volts: — 600V
Amps: — 30-60A (See Catalog Number table for details) **Agency Information:** CE, Designed to accommodate the compact range of offset blade fuse to CSA C22.2 No. 106, HRCI-CB.
**Mounting:** 35mm DIN-Rail or single screw mounting.
## **Catalog Numbers***
|**Catalog**|**Amp**||**Fuse**|
|---|---|---|---|
|**Catalog**<br>**Numbers**<br>C30F|**Amp**<br>**Ratings**|**Connection**<br>Front|**Fuse**<br>**Accepted**|
|C30F|30|Front|_CIF06|
|C30BS||Back||
|C30FBS||Front-Back||
|C60F|60|Front|EK-Amp|
|C60BS||Back||
|C60FBS||Front-Back||
*For use with HRCI-CB Fuses.
**Data Sheet: 4133**
**Data Sheet: 4132**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**263**
## Quik-Spec coordination | panelboards
The new Quik-Spec coordination panelboard with a footprint up to 40% smaller than other fusible panelboards is now available up to 1200A
**264**
## **Quik-Spec[™] Electrical Gear**
## **Section Contents**
**Page**
**Quik-Spec Coordination Panel Boards . . . . . . . . . 266-267 Quik-Spec Power Module Switches and Panels . . 268-269 Quik-Spec DC Safety Switches . . . . . . . . . . . . . . . . . . 270 Quik-Spec AC Safety Switches . . . . . . . . . . . . . . . . . . 271 A/C Disconnects - Fused and Non-Fused . . . . . . . . . . .272**
**RED indicates NEW information** [
Scan this tag to get the latest product information for Quik-Spec Coordination Panel Boards.
**265**
**Quik-Spec[™] Electrical Gear**
## **30-400A Quik-Spec™ Coordination Panelboard**
## **Specifications**
**Description:** Configurable fusible panelboard with 30-400A mains and branches from 1-100A rated 600Vac.
## **Ratings:**
Volts:— 600Vac (or less), 125Vdc (or less)** Bus Amps:— 30, 60, 100, 200, 225 or 400A
## **Options:**
Main: — MLO (main lug only)
- Fused disconnect switch
- Non-fused disconnect switch
Enclosure: — NEMA 1 or 3R
- Standard size panelboard (20˝ W x 5˝ D x various heights)*
- For other ratings consult factory
Panel: — Feed; Top & Bottom***
- Mounting; Surface or Flush****
- Door/Trim; Regular or Door-in-Door****
- Branch: — Circuits; Up to 18, 30 and 42*
- Amps; Up to 100A
- Type; 1-, 2- and 3-Pole
Fuse: — Six-fuse spare fuse compartment
- Time-delay or UPS/critical applications (fast-acting) CUBEFuse™
Assembly
SCCR:— 200kA, 100kA or 50kA AC,100kA or 20kA@125Vdc*
Through-Lugs
& Loadside
Disconnect:— Feed-Through - single and double
- Fused loadside disconnect, ≥100A-≤200A (400A panels only)
Neutrals:— 200A and 400A Unbonded and Bonded
Ground:— Non-Isolated or Isolated
- *Depending on configuration
- **125Vdc rating applicable to 40 amp or less CCPBs on MLO panels only.
- ***Top feed not available on NEMA 3R enclosure
- ****Flush mount and Door-in-Door not available with NEMA 3R enclosure
**Agency Information:** UL Listed to UL 67, complies with NFPA 70 (NEC[®] ; National Electric Code),
## **Features and Benefits:**
- UL and CSA listing makes it easy to address NEC[®] selective coordination requirements in an all fused system
- Value-engineered for greater flexibility with up to 400A mains, 200kA SCCR, 100A branches with 18, 30 and 42 branch positions
- Same size footprint as traditional circuit breaker panelboards and 40% smaller than standard fusible panelboards: 20˝ W x 5[3] ⁄4˝ D x various heights (depending on configuration)
- Increase safety with current-limiting finger-safe Low-Peak CUBEFuse that reduces arc flash hazard levels
- Quik-Quote online configurator makes specifying and ordering easy – delivers a full bill of material and submittal drawings for an entire project
- Available for 10 day shipment with QuikShip™ service
## **Ordering:**
The QSCP is factory configured to the specific electrical system. Contact your Bussmann distributor or representative to place your order. Have all relevant electrical and circuit information on hand.
QuikShip – 10 Business Day Shipment
**Data Sheet: 1159**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**266**
a **Quik-Spec[™] Electrical Gear**
## **600-1200A Quik-Spec™ Coordination Panelboard**
## **Specifications**
**Description:** Fusible panelboard with 600, 800 and 1200A mains and branches from 1-600A, rated 600Vac.
## **Ratings:**
Volts:— 600Vac (or less), 125Vdc Amps:— 600, 800 and 1200A
## **Options:**
Main: — Main lug only
Enclosure: — NEMA 1 floor mount
Branch: — 1-, 2- and 3-pole, 15-600A branch disconnect
- Fuse: — Time-delay, non-indicating (Class CF TCF_R and/or Class J LPJ_SP)
- Time-delay, indicating (Class CF TCF_ and/or Class J LPJ_SPI)
- Fast-acting, non-indicating (Class CF TCF_RN and/or Class J JKS)
- DFJ high speed Class J fuses
**Agency Information:** Complies with NFPA 70 (NEC[®] ; National Electrical Code[®] ) UL Listed to UL 67,
## **Features and Benefits:**
- Configurable panelboards with options for 600, 800 and 1200A mains and branches from 1-600A all rated 200kA SCCR at 600Vac
- Smallest standard fusible panelboards in the industry
- Featuring the finger-safe UL Class CF CUBEFuse with 1-600A ampacity rejection features (1-100A)
- Available with time-delay or UPS/Critical application fast-acting fuses
## **Configuration and Dimension Chart**
• UL listing makes it simple to address NEC[®] selective
coordination system requirements in an all fused system
- Quik-Quote online configurator makes specifying and ordering easy – delivers a full bill of material and submittal drawings for an entire project
## **Ordering:**
The QSCP is factory configured to the specific electrical system. Contact your Bussmann distributor or representative to place your order. Have all relevant electrical and circuit information on hand.
QuikShip – 10 Business Day Shipment
|**Panel**<br>**Ampacity**<br>600A<br>800A<br>1200A|**Branch Configurations**|**Dimension**<br>**(inches)**<br>**H**<br>**W**<br>**D**<br>65<br>27<br>15<br>89<br>38<br>15<br>65<br>38<br>15<br>89<br>38<br>15<br>89<br>38<br>15<br>102<br>38<br>15|**Dimension**<br>**(inches)**<br>**H**<br>**W**<br>**D**<br>65<br>27<br>15<br>89<br>38<br>15<br>65<br>38<br>15<br>89<br>38<br>15<br>89<br>38<br>15<br>102<br>38<br>15|
|---|---|---|---|
|||**(inches)**<br>**H**|**(inches)**<br>**W**|
||(18) 1-100A|65|27|
||(18) 1-100A+200A single|||
||(18) 1-100A+200A twin|||
||(18) 1<br>200A single+200A single|||
||200A single200A single<br>200A single+200A twin|||
||200A single<br>200A twin+200A twin|||
||(2) 300A single|89|38|
||(2) 300A single<br>(18) 1-100A+200A single|65|38|
||(18) 1200A single<br>(18) 1-100A+200A twin|||
||(18) 1<br>(2) 200A twin|||
||(2) 200A twin<br>(18) 1-100A+400A single|89|38|
||(18) 1400A single<br>200A twin+400A single|||
||400A single<br>(2) 400A single|||
||(2) 400A single<br>(18) 1-100A+600A single|89|38|
||(18) 1600A single<br>(3) 200A twin|||
||(3) 200A twin<br>200A twin+600A single|||
||600A single<br>(2) 200A twin+400A single|||
||(3) 400A single|102|38|
||(3) 400A single<br>600A single+400A single+200A single|||
||600A single400A single200A single<br>600A single+400A single+200A twin|||
||600A single400A single<br>(2) 600A single|||
**Data Sheet: 1171**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**267**
**Quik-Spec[™] Electrical Gear**
## **Quik-Spec™ Power Module — All-in-one Elevator Disconnect**
## **PS & PMP**
## **Typical Applications:**
- Elevator Disconnects
## **Bussmann Quik-Spec Power Module**
## **Specifications**
**Description:** Fusible power switch or panel with shunt trip and fire safety interface to allow for single point tie in with fire alarm system.
## **Ratings:**
Volts:— 600Vac, 3Ø
Amps:— 30-400A (PS)
- 30-200A (PMP feeder switches)
- 400-800A (PMP main switches*)
Assembly
- Computer Room Shunt Trip Disconnect
- Fire Safety Interface Relay
## **Accessories:**
- For added safety, use the Bussmann SAMI™ fuse covers to improve maintenance personnel protection (OSHA 1910.333, paragraph C)
## **Ordering:**
The Bussmann Quik-Spec™ Power Module Switch and Panel are factory configured to the specific application. Contact your Bussmann representative to place your order. Have all relevant electrical and circuit information on hand.
SCCR:— 200kA RMS
- *Contact Bussmann for applications greater than 800A.
**Agency Information:** Complies with NFPA 70 (NEC[®] ; National Electrical Code[®] ),
- Elevator Shutdown – ANSI/ASME A17.1, 2.8.3.3.2
## **PS***
The Quik-Spec™ Power Module Switch (PS) for single elevator applications.
- NEC[®] 620.51(B) (Elevator Shutdown)
- – NEC[®] 240.12 (Orderly Shutdown)
- Shunt Trip Voltage Monitoring – NFPA 72, 6.16.4.4
- Selective Coordination – NEC[®] 620.62
- Auxiliary Contact (Hydraulic Elevator) – NEC[®] 620.91(C)
- Power Module Switch (PS); UL Listed (UL 98) Enclosed and Dead front switch Guide 96NK3917, File E182262, NEMA 1, UL 50 Listed enclosure**, cUL per Canadian Standards C22.2, No. 0-M91-CAN/CSA
- C22.2, No. 4-M89 Enclosed switch.
- **NEMA 12, 3R, and 4 enclosures also available
- Power Module Panel (PMP); UL 98 Enclosed and Deadfront Switches.
## **PMP***
Power Module™ Panel (PMP) for multiple elevator applications.
## **Features and Benefits:**
- Internally powered, relay activated shunt trip system
- Mechanically interlocked auxiliary contact
- Self-contained adherence to elevator consensus standards, NFPA 70 (NEC[®] ). NFPA 72, ANSI/ASME 17.1
- Shunt trip capability
- Selective coordination
- Fire safety signal interface
- Shunt trip voltage monitoring
- Component protection via Bussmann Low-Peak™ Class J fuses
- UL 98 Listed for 200kA short-circuit current rating
- Lockable in the open position with three-lock capability
**==> picture [82 x 29] intentionally omitted <==**
**----- Start of picture text -----**<br>
Scan this tag to get the<br>latest videos for the<br>Power Module.<br>**----- End of picture text -----**<br>
- Optional key-test switch and optional pilot light for easy inspection
- No annual calibration or testing of overcurrent protection required
- Padlockable for service-work safety and open-door “override” for troubleshooting
*Fused main disconnect requires Class J fuses, not supplied with switch.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**268**
**Quik-Spec[™] Electrical Gear**
## **Quik-Spec™ Power Module — All-in-one Elevator Disconnect**
## **Hydraulic Elevators**
Hydraulic elevators need battery backup to help prevent stranding passengers. To keep the elevator from moving when it’s been manually shut down for maintenance, the NEC[®] requires battery backup be connected to the elevator disconnecting means through an auxillary contact.
However, an unintended consequence can be passengers getting stranded because of devices that open automatically (circuit breakers and disconnects utilizing a
molded case switch with a trailing fuse block) will operate with a fault on their loadside. That operation also disables the battery backup and strands passengers. That’s why the Power Module has a non-automatic fusible shunt trip switch. If the Power Module has a fault on its loadside, the fuses open and the battery stays enabled. Thus the Power Module ensures that battery power is enabled when the passengers need it to exit - and disabled to allow safe maintenance of the elevator and hoistway.
|**Scenario**|**Battery**<br>**Lowering**<br>**Required**|**Reason**|**Offered By**<br>**Power**<br>**Module™**|**Offered By**<br>**Other Elevator**<br>**Disconnects**|
|---|---|---|---|---|
|Power failure|Yes|Need to lower elevator to allowpassengers to exit.|Yes|Yes|
|Fire in shaft or<br>machine room|No|Recall is initiated by smoke detector and lowers elevator to<br>a safe floor. Batterynot needed.|Yes|Yes|
|Disconnect manually<br>opened|No|Worker to perform maintenance. Elevator must remain<br>stationarytoprevent injury.|Yes|Yes|
|Fault on loadside of<br>disconnect|Yes|Need to lower elevator to allow passengers to exit.|Yes|No|
## **Quik-Spec™ Power Module Switch Catalog Numbering System**
> Power Module Switch Catalog Number System PS 1 T48 R1 K G N1 B F1 U PS = Power Module Switch Amp Rating[†] 3 = 30A 1 = 100A 4 = 400A 6 = 60A 2 = 200A Control Transformer*[†] T20 = 208 Volt T48 = 480 Volt T24 = 240 Volt T60 = 600 Volt Fire Safety Interface Relay (3PDT, 10A, 12V)[†] R1 = 120Vac Coil R2 = 24Vdc Coil
Optional Key Test Switch K = Key Optional Pilot Light ON G = Green R = Red W = White Optional Neutral Lug[†][†] N6 = 30-60A N2 = 200A N1 = 100A N4 = 400A Auxiliary Contacts[†] B = 2 NO/NC Fire Alarm Voltage Monitoring Relay (To Monitor Shunt Trip Voltage) F1 = Single-Pole F3 = Three-Pole** Optional NEMA Enclosures (Type 1 Standard With No Suffix Designation Required) U = Type 3R Z = Type 12 Y = Type 4
* 100Va with Primary and Secondary fusing (120V Secondary) ** Only for use with R1 option † Required equipment. †† Neutral lug rating should be equal to or greater than the switch amp rating.
## Quik-Ship Program: Switch - 3 Days, Panel - 10 Days!
Ship-direct service within three business days for Power Module Switches (PS_) and 10 business days for Power Module Panels (PMP_).
- Three day PS_ shipment requires ordering from catalog numbers shown.
** 10 Day PMP_ shipment covers NEMA 1 enclosures with the ampacities shown and all requirements for relay type (AC or DC), accessory options and number of switches. To order PMP_, contact your Bussmann representative with all relevant electrical and circuit information, we do the rest.
**==> picture [220 x 75] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power Module Switch* Power Module Panel**<br>Cat Numbers Amps Volts Cat. Numbers Amps<br>PS6T48R1KGBF3-X 60A 480V PMP-400-X 400A<br>PS1T48R1KGBF3-X 100A 480V PMP-600-X 600A<br>PS1T20R1KGBF3-X 100A 208V PMP-800-X 800A<br>PS2T48R1KGBF3-X 200A 480V<br>PS2T20R1KGBF3-X 200A 208V<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**269**
**Quik-Spec[™] Electrical Gear**
## **Quik-Spec™ DC Safety Switch**
## **Isolating DC Circuits Has Never Been Easier** _**or**_ **Safer**
- Flexibility of Application
- Enhanced Finger-Safe Design
- Flange Handle Operation
- Current-Limiting Fuses Reduce Arc Flash Hazard
- Meets UL and NEC[®] Requirements
NEC 690.17 Compliant Label
Warns that the switch terminals may be energized in the open position
## High Visibility Padlockable Handle
Easy to operate with gloves and up to three padlocks to protect maintenance personnel
## Visible Switch Contacts
Positive visual identification of switch state
## Door Interlock
Prevents opening door while energized, but can be manually overridden for testing or inspection.
## Clear Polycarbonate Deadfront
Covers energized parts to provide added protection against electrical hazards. Lineside stays in place during fuse servicing.
## Fused Version For Added Protection
## NEMA 3R, 12 & 4X Enclosures
Meet many application requirements. 3R and 4X stainless steel well suited for isolating outdoor solar power installations
Fuse clips located on switch center pole to ensure both clips are de-energized in OFF position. Meets NEC[®] Article 690.16 that requires isolating the fuse from all potential supply sources. Cooper Bussmann recommends using the Limitron fast-acting, current limiting PVS-R Class RK5 fuse (order separately.)
## Conduit Knockouts
For easy conductor installation
## **Type 3R Dimensions**
## **Dimensions - in**
Amps A B C Main Lug Capacity Neutral Lug Capacity ISC 30 16.35 8.87 9.89 #2 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 19.2 60 16.35 8.87 9.89 #2 AWG- #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 38.4 100 22.15 11.84 9.89 1/0 AWG- #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 64.0 200 28.27 16.66 11.26 250kcmil - #6 AWG Al/Cu #2 AWG - #14 AWG Al/Cu 128.0 **Type 12 & 4X Dimensions** Amps A B C Main Lug Capacity Neutral Lug Capacity ISC 30 & 60 14.14 8.76 10.22 #2 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 19.2 Non-fusible 30 & 60 19.08 8.76 10.22 #2 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 19.2 Fusible 100 24.95 11.79 10.22 1/0 AWG- #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 64.0 200 35.38 16.95 11.63 250kcmil - #6 AWG Al/Cu #2 AWG - #14 AWG Al/Cu 128.0 ~~semi)~~ DC Safety Switch Catalog Numbering System Use this build-a-code to specify the exact Quik-Spec DC Safety Switch you need.
BD 1 6 1 F R Prefix Voltage Type BD = Heavy Duty 6 = 600Vdc F = Fusible with DC Safety Switch neutral N = Non-fusible with neutral Poles Amps Enclosure Type 1 = 1-Pole 1 = 30A R = NEMA 3R 2 = 60A D = NEMA 12 3 = 100A W = NEMA 4X 4 = 200A Stainless ~~et~~ **270** For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**==> picture [103 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
Typical Wiring Diagram<br>Fused Non-Fused<br>Line Line<br>Neutral Neutral<br>Load Load<br>**----- End of picture text -----**<br>
**Quik-Spec[™] Electrical Gear**
## **Quik-Spec™ Safety Switch**
## **Bussmann Quik-Spec™ Safety Switch**
## Standard Features:
- Extended line terminal shield and finger-safe 30, 60, or 100A Bussmann CUBEFuse
- 200kA short-circuit current rating
- Visible double break quick-make, quick-break rotary blade mechanism
- Triple padlocking capability
- Mechanically interlocked door
- 600Vac/250Vdc maximum
## Optional Features:
- Viewing window for visible blades and open fuse indication
- NEMA 1, 3R, 12, 4X (stainless)
- Suitable for use as service equipment (with neutral kit)
## **Dimensions - inches (mm)***
## **NEMA 1 & 3R**
## **Specifications**
**Description:** The Bussmann Quik-Spec™ Safety Switch equipped with finger-safe Low-Peak CUBEFuse provides superior safety and reliability for industrial customers.
Utilizing the Bussmann Class CF Low-Peak CUBEFuse, the Quik-Spec Safety Switch provides Class J fuse performance characteristics that can help mitigate incident energy and arc-flash hazard, and offers excellent component protection. The Bussmann CUBEFuse requires no tools to install or replace.
## **Agency Information:**
- UL 98 standard for enclosed deadfront switches.
- UL 50 standard for en ~~c~~ losures for ~~el~~ ectrical equipment.
- NEMA KS 1.
- UL Listed, File E5239.
- cUL Listed to C22.2 No.4-M89.
*See Data Sheet 1156 for 4X and 12 dimension information and maximum horsepower ratings.
**==> picture [460 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
Quik-Spec [™] Safety Switch Catalog Numbering System<br>CF 3 6 1 F G K W<br>Switch Type Voltage Fusible Series Window (Optional)<br>CF CUBEFuse=Heavy Duty™ 6 =600Vac FN = Fusible=Fusible with K = Switch W = Window<br>Safety Switch Neutral*<br>Poles Amp Enclosure Type<br>3 = 3-Pole 1 = 30A G = NEMA 1<br>2 = 60A R = NEMA 3R<br>*Suitable for service entrance use 3 = 100A D = NEMA 12<br>with neutral kit installed. W = NEMA 4X Stainless<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**271**
**Quik-Spec[™] Electrical Gear**
## **A/C Disconnects — Fused and Non-fused**
## **Series B22__**
## **Specifications**
**Description:** Fused and non-fused rainproof pullout air conditioner units.
**Dimensions:** See Catalog Numbers table.
**Construction:** NEMA 3R metal housing with weather resistant coating.
**Wire Range:** 14-3 AWG, Al/Cu
## **Ratings:**
Phase: — Single, 2-wire Volts: — 240Vac
Amps: — 30-60A **Agency Information:** UL Listed to UL 1429, cUL Certified, UL Guide WGEW
## **Features and Benefits**
- A/C disconnects meet NEC[®] Code Requirements under articles 440.14. GFCI units meet NEC[®] Code Requirements under articles 210.63, 210.8, and 406.8(B)(1).
- NEMA 3R rainproof enclosures withstand outdoor environment.
**==> picture [206 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Metallic Fused Disconnect Metallic Non-Fused Disconnect<br>**----- End of picture text -----**<br>
Metallic Non-Fused Disconnect with Weather ResistantTamper Resistant GFCI Receptacle.
- Padlockable with two-position pullout handle to lock safety shield when in the ON position. (Not available on GF or NA units.) For added safety, pullout handle can be stored in the compartment in the off position.
## **Typical Applications**
- Residential, light industrial/commercial A/C and heat pump service.
- Spas/whirlpools, swimming pools, pump houses.
- Suitable for service entrance equipment applications with field installable ground bar, kit number DPFG.
## **Catalog Numbers**
## **Fused**
|**Fused**<br>**Catalog Numbers**<br>**Description**|**Disconnect**<br>**Rating**|~~**Max Hp Rating**~~|~~**Max Hp Rating**~~|**Wire Range**<br>**60 or 75°C Cu/Al**|**Enclosure**<br>**Type**|**Fuse**<br>**Class**|**Approx. Dimensions (in)**|**Approx. Dimensions (in)**|**Approx. Dimensions (in)**|
|---|---|---|---|---|---|---|---|---|---|
|||~~**Max Hp Rating**~~<br>**120V**|~~**Max Hp Rating**~~<br>**240V**||||**Approx. Dimensions (in)**<br>**Height **|**Approx. Dimensions (in)**<br> **Width **|**Approx. Dimensions (in)**<br> **Depth**|
|B221-30F<br>30A, Pullout<br>B221-30FGF<br>30A, Pullout w/ GFCI<br>B221-30FGFWRTR<br>30A, Pullout w/ WRTR-<br>Rated GFCI<br>B222-60F<br>60A, Pullout<br>B222-60FGF<br>60A, Pullout w/ GFCI<br>B222-60FGFWRTR<br>60A, Pullout w/ WRTR-<br>Rated GFCI|30A<br>30A<br>30A<br>60A<br>60A<br>60A|1.5<br>1.5<br>1.5<br>3<br>3<br>3|3<br>3<br>3<br>10<br>10<br>10|#14-3<br>#14-3<br>#14-3<br>#14-3<br>#14-3<br>#14-3|NEMA 3R<br>NEMA 3R<br>NEMA 3R<br>NEMA 3R<br>NEMA 3R<br>NEMA 3R|H or R<br>H or R<br>H or R<br>H or R<br>H or R<br>H or R|83⁄4<br>13<br>13<br>83⁄4<br>13<br>13|53⁄8<br>71⁄2<br>71⁄2<br>53⁄8<br>71⁄2<br>71⁄2|27⁄8<br>43⁄4<br>43⁄4<br>27⁄8<br>43⁄4<br>43⁄4|
|**Non-Fused**<br>B222-60NF<br>60A, Pullout<br>B222-60NFGF<br>60A, Pullout w/ GFCI<br>B222-60NFGFWRTR<br>60A, Pullout w/ WRTR-<br>Rated GFCI<br>B222-60NFNA<br>60A, Switch|60A<br>60A<br>60A<br>60A|3<br>3<br>3<br>*|10<br>10<br>10<br>10|#14-3<br>#14-3<br>#14-3<br>#14-3|NEMA 3R<br>NEMA 3R<br>NEMA 3R<br>NEMA 3R|*<br>*<br>*<br>*|83⁄4<br>113⁄4<br>113⁄4<br>83⁄4|53⁄8<br>61⁄2<br>61⁄2<br>53⁄8|27⁄8<br>41⁄2<br>41⁄2<br>35⁄8|
30 and 60A pullout replacement handle: 96-3258-4.
- *Upstream overcurrent protective device (OPCD) not to exceed 60A.
**Data Sheet: 1143**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**272**
## **Fuse Holders and Blocks**
|**Section Contents Page**|
|---|
|**CH Series Global Modular fuse holders**|
|**and accessories . . . . . . . . . . . . . . . . . . . . . 274-280**|
|Remote Fuse Monitoring - CH-PLCCH . . . . . . . . . . . . 278|
|Comb-Bus bar specifications and selection guide . . . .279|
|Comb-Bus bar features and installation guide . . . . . . 280|
|CH Series Class J modular fuse holders . . . . . . . . . . . . 281|
|OPM-1038 3-pole fuse holders with|
|disconnect switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282|
|OPM-1038 3-pole fuse holders . . . . . . . . . . . . . . . . . . . 283|
|OPMNGA- 3-pole Class CC and13⁄32˝ X 11⁄2˝|
|fuse overcurrent protection modules . . . . . . . . . . .284-285|
|JT(N)60030 & JT(N)600600 Safety J™ Class J|
|fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286-287|
|SAMI™ fuse covers . . . . . . . . . . . . . . . . . . . . . . . . . . . 288|
|Modular Knifeblade Fuse Holders<br>289-290|
|Class R, H(K), 250 & 600V . . . . . . . . . . . . . . . . . 291-292|
|Class J, 600V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293|
|H250 & R250 Series 250V Class H (K) and|
|R fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . .294-295|
|H600 & R600 600V Class H (K) and|
|R fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . .296-297|
|J600 Series Class J fuse blocks . . . . . . . . . . . . . . . . . 298|
|JP Series Class J fuse blocks . . . . . . . . . . . . . . . . . . . . 299|
|T300 300V Class T fuse blocks . . . . . . . . . . . . . . . 300-301|
|T600 600V Class T fuse blocks . . . . . . . . . . . . . . . 302-303|
|BCA Series Class CC add-a-pole modular|
|fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304|
|BMA Series13⁄32˝ X 11⁄2˝ fuse add-a-pole modular|
|fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304|
|BC Series Class CC fuse blocks . . . . . . . . . . . . . . . . . .305|
|BM Series Type M13⁄32˝ X 11⁄2˝ fuse blocks . . . . . . . . . . . 305|
|BG & G Series Class G fuse blocks . . . . . . . . . . . . . . .305|
|BH Series high speed fuse modular fuse blocks . . . . . 306|
|Class H & J modular fuse blocks . . . . . . . . . . . . . . . . . .306|
|Plug fuse box cover units . . . . . . . . . . . . . . . . . . . . . . .307|
|HFB & HEB-10 in-line fuse holders|
|for1⁄4˝ X 11⁄4˝ fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . .308|
|HHB & HRK universal in-line fuse holders for|
|1⁄4˝ dia. fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308|
|HR & HM Series in-line fuse holders for1⁄4˝ dia. fuses . . 309|
|HFA Series waterproof in-line fuse holders|
|for1⁄4˝ X 11⁄4˝ fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . .309|
|HHT Series in-line fuse holders for|
|5 X 15 to 20mm fuses . . . . . . . . . . . . . . . . . . . . . . . . .309|
|Tron™in-line fuse holders(New HEZ). . . . . . . . . . . . 309-311|
|Panel mounted fuse holders for 5 X 20mm fuses . . . . . . .312|
|Panel mounted fuse holders for1⁄4˝ X 11⁄4˝ fuses . . . . . . . .313|
|Panel mounted fuse holders for 5 X 20mm and|
|1⁄4˝ X 11⁄4˝ fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314-315|
|Panel mounted fuse holders for indicating type fuses . . 316|
|Panel mounted fuse holders for|
|13⁄32˝ X 15⁄16˝ to 11⁄2˝ fuses . . . . . . . . . . . . . . . . . . . . . . . . .317|
|Panel mounted fuse holders for|
|13⁄32˝ X 11⁄2˝ fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318|
|Fuse blocks for1⁄4˝ X 11⁄4˝ fuses . . . . . . . . . . . . . . . . . . . . 319<br>Fuse blocks for1⁄4˝ X 1˝ fuses . . . . . . . . . . . . . . . . . . . . . .320<br>Fuse blocks for13⁄32˝ X 11⁄2˝ fuses . . . . . . . . . . . . . . . . . . . .321<br>Rail mount fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . . 322<br>**REDindicates NEWinformation**<br>~~TT~~|
**273**
**Fuse Holders and Blocks**
## **Global Modular Fuse Holders**
## **CH Series - 8x32, 10x38, 14x51, 22x58, Class CC**
## **Specifications**
**Description:** The ‘CH’ line of modular fuse holders accommodates many fuses from around the world, including North American Class-CC, Midget, Class gR, aR HSF, and IEC Industrial Ferrule (Class gG and aM) in four physical sizes: 8x32, 10x38, 14x51 and 22x58mm.
Agency Information: UL File E14853
Guide IZLT Listed, IZLT2 Recognized CSA: File 47235, CHPV and CHM - Class 6225-30, CHCC - Class 6225-01
Ratings:
600V/30A (UL) 690V/32A (IEC)
Wire Range: #18 to #4 (0.8mm[2] to 21.1mm[2] )
Torque Ratings: 30 Lb-In (3.4 N•m) maximum
Flammability Ratings: UL 94V0, self-extinguishing
Storage & Operating Temperature Range:
- -20ºC to +90ºC (indicating)
- -20ºC to +120ºC (non-indicating)
## **Features/Benefits**
- High SCCR rated, UL Listed Class CC holder with indicator option for 600Vac/dc and 48Vdc.
- UL Recognized midget and 10 x 38 holders with factory assembled neutral pole option.
- Agency ratings up to 1000Vdc for use with solar PV fuses.
- Available remote PLC indication with the CH-PLC module.
- Terminals rated for use with 75ºC or 90ºC wire, fine stranded wire, spade terminals and comb-bus bars. Use any higher temperature rated wire with appropriate derating.
- Complete range of UL Listed and high SCCR rated 1-phase and 3-phase finger-safe comb-bus bars and power feed lugs.
|**Series &**<br>**Size**<br>~~|~~|**Catalog Number**<br>~~————~~|**Catalog Number**<br>~~————~~|**Voltage &**<br>**Current**<br>~~————|~~|**Agency**<br>**Markings**<br>f~~j~~|**Number**<br>**of Poles**<br>~~j~~<br>~~|~~|**Terminal**<br>**Rating**<br>~~ff~~|**SCCR**<br>**Rating**<br>~~ff~~|**Cooper Bussmann**<br>**Fuses**<br>~~ff~~|
|---|---|---|---|---|---|---|---|---|
||**With**<br>**Indicator**<br>**Catalog Number**<br>~~————~~|**Without**<br>**Indicator**<br>**Catalog Number**<br>~~————~~|||||||
|**CHM**<br>**10x38**<br>**and**<br>**Midget**<br>~~| ~~<br>~~—~~|CHM1DIU<br>~~————~~<br>~~==ln=~~|CHM1DU<br>~~————~~<br>~~==ln=~~|UL<br>600V/30A;<br>IEC<br>690V/32A<br>~~———— |~~<br>~~==ln=~~|**Markings**<br>cURus; IEC<br>60269-2<br>f~~j~~<br>~~==ln=~~|1<br>~~j~~<br>~~|~~<br>~~==ln=~~|1 pole + 1<br>**Rating**<br>Solid,<br>Stranded,<br>Fine<br>Stranded,<br>Spade<br>Lug, Comb<br>Bus Bar;<br>Single and<br>Dual Wire;<br>75ºC and<br>90ºC Cu<br>wire<br> ~~ff~~|**Rating**<br>Lug, Comb<br>Single and<br>100kA<br>rms sym<br>~~ff~~|FNQ, KLM, FNM,<br>KTK, BAF, FWA,<br>DCM, C10 SERIES,<br>AGU, BAN, FWC<br>~~ff~~|
||CHM2DIU<br>~~————~~<br>~~———~~<br>~~==ln=~~|CHM2DU<br>~~————~~<br>~~———~~<br>~~==ln=~~|||2<br>~~j~~<br>~~|~~<br>~~rsSY~~<br>~~==ln=~~||||
||CHM3DIU<br>~~————~~<br>~~———~~<br>~~==ln=~~|CHM3DU<br>~~————~~<br>~~———~~<br>~~==ln=~~|||3<br>~~j~~<br>~~|~~<br>~~rsSY~~<br>~~rsd~~<br>~~==ln=~~||||
||CHM4DIU<br> ~~————~~<br>~~———~~<br>~~==ln=~~|CHM4DU<br>~~————~~<br>~~———~~<br>~~==ln=~~|||4<br>~~j~~<br>~~| ~~<br>~~rsSY~~<br>~~rid~~<br>~~==ln=~~||||
||CHM1DNIU<br>~~———~~<br>~~==ln=~~|CHM1DNU<br>~~———~~<br>~~==ln=~~||60269-2<br>~~==ln=~~|1 pole + 1<br>neutral<br>~~rsSY~~<br>~~==ln=~~||||
||CHM3DNIU<br>~~———~~<br>~~==ln=~~|CHM3DNU<br>~~———~~<br>~~==ln=~~|||3 poles +<br>1 neutral<br>~~rsSY~~<br>~~==ln=~~||||
||CHM1DI-48U<br>~~==ln=~~<br>~~—~~|~~==ln=~~<br>~~—~~|UL 48Vdc/30A;<br>IEC<br>48Vdc/32A<br>~~==ln=~~<br>~~pf~~|UL 48Vdc/30A;<br>~~==ln=~~<br>~~pf~~|1<br>~~==ln=~~<br>~~pf~~||||
||~~—~~|CHM1DNXU<br>~~—~~|IEC 690V/32A<br>~~pf~~|IEC60269-2<br>~~pf~~|1 neutral<br>~~pf~~||n/a<br>Single and<br>Dual Wire;|n/a|
|**CHPV**<br>~~—~~|CHPV1IU<br>~~—~~<br>~~—_~~|CHPV1U<br>~~—~~<br>~~—_~~|UL & IEC;<br>1000Vdc/30A<br>~~pf~~|UR, CSA,<br>UL4248-18,<br>IEC60269-1<br>~~pf~~<br>~~eS~~|1<br>~~pf~~||Dual Wire;<br>33kA rms<br>sym<br>~~fo~~|Solar PV series<br>~~fo~~|
||CHPV2IU<br>~~—~~<br>~~—_~~|CHPV2U<br>~~—~~<br>~~—_~~|||2<br>~~pf~~<br>~~|~~<br>~~eS~~||||
|**CHCC**<br>**Class CC**<br>~~ees~~|CHCC1DIU<br>~~—_~~<br>~~ees~~|CHCC1DU<br>~~—_~~<br>~~ees~~|UL 600V/30A<br>~~ees~~|UL 48Vdc/30A<br>cULus<br>~~ees~~<br>~~eS~~|1<br>~~ees~~<br>~~eS~~||200kA<br>rms sym<br>~~fo~~|LP-CC, FNQ-R,<br>KTK-R<br>~~fo~~|
||CHCC2DIU<br>~~—_~~<br>~~ees~~|CHCC2DU<br>~~—_~~<br>~~ees~~|||2<br>~~ees~~<br>~~eS~~<br>~~rsd~~||||
||CHCC3DIU<br>~~—_~~<br>~~ees~~|CHCC3DU<br>~~—_~~<br>~~ees~~|||3<br>~~ees~~<br>~~eS~~<br>~~rsd~~||||
||~~—_~~<br>~~ees~~|CHCC1DI-48U<br>~~—_~~<br>~~ees~~|UL 48Vdc/30A<br>~~ees~~||1<br>~~ees~~<br>~~eS~~<br>~~rCSY~~||||
**Fuse Holders and Blocks**
## **Rail Mount Fuse Blocks and Holders**
**==> picture [480 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
CHM & CHMI CHCC & CHCCI CHPV & CHPVI<br>on =>. -————-.<br>e\ (8.3-21.1mm(((((0.82.0.8-2.0mm0.8-2.0mm3.3-5.2mm18-14 AWG18-14 AWG14-10 AWG12-10 AWG18-16 AWGWire Range8-4 AWG0 Indication Min Voltage: 90V -- Degree of Protection IP20Rated: 600V, 30A 50/60Hz 5N/A1.3mm.2mmDO NOT OPEN UNDER LOAD 200kA RMS SYM 3W USE MIDGET / 10X38 FUSE 690Vac 120kA 3W 75ºC OR 90ºC CU WIRE IEC: 60269-2 32ASeries: CHM [2][2][2][2][2] ))))) [2] ) Comb BusConductorStranded,StrandedStTerminalSpadeSolid,rTypeFineanded ConductorsSingleSingleNo. ofDual 25 in-lbs20 in-lbs30 in-lbs2.8 Nm3.4 NmTorque2.3 Nm ©On )Fn U \ © Q (8.3-21.1mm((0.8(((2.3.3-5.2mm0.8-2.0mm0.8-2.0mm18-14 AWG18-14 AWG18-16 AWG14-10 AWG12-10 AWGWire Range8-4 AWG0 Indication Min Voltage: 90V -- Degree of Protection IP20Rated: 600V, 30A 50/60Hz N/A1.3mm5.2mmDO NOT OPEN UNDER LOAD Series: CHCC 75ºC OR 90ºC CU WIRE 200kA RMS SYM USE CLASS CC FUSE [2][2][2][2][2] ))))) [2] ) Comb BusConductorStranded,StrandedStTerminalSpadeSolid,rTypeFineanded ConductorsSingleSingleNo. ofDual 30 in-lbs20 in-lbs25 in-lbs3.4 Nm2.8 NmTorque2.3 Nm Oo]o m XQ © Rated: 1000Vdc, 30A 33kA RMS SYM (8.3-21.1mm(0.8((((0.8-2.0mm2.3.3-5.2mm0.8-2.0mm18-16 AWG14-10 AWG12-10 AWG18-14 AWG18-14 AWGWire Range8-4 AWG0--USE PHOTOVOLTAIC 10X38 FUSE Indication Min Voltage: 90V 1.3mm5N/A Degree of Protection IP20 .2mmDO NOT OPEN UNDER LOAD 1000Vdc 33kA 3.5W 75ºC OR 90ºC CU WIRE Series: CHPV [2][2][2][2][2] IEC: 60269-1 32A ))))) [2] ) Comb BusConductorStranded,StStrandedTerminal UL4248-18 SpadeSolid,rTypeFineanded ConductorsSingleSingleNo. ofDual 25 in-lbs20 in-lbs30 in-lbs3.4 Nm2.8 NmTorque2.3 Nm o© m1F u<br>\ at R GB13539 | \.@. GB13539 R 4GY1 GB13539<br>° MADE INCHINA “ity 4 / r 430PMADE INCHINA “€ii© 1 | \\ €. MADE IN Ome CHINA Thi 5 yy ,|<br>**----- End of picture text -----**<br>
**==> picture [59 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
Features<br>**----- End of picture text -----**<br>
**==> picture [290 x 211] intentionally omitted <==**
**----- Start of picture text -----**<br>
Hole for Wire OptionalOpen Fuse<br>Security Tag Indicator<br>Label Slot<br>4mm Self-Extinguishing,<br>Lockout UL 94V0 Rated<br>Feature in Polyester<br>Fuse Carrier Material<br>Captive, Fully<br>Backed Out<br>Phil-Slot Screw<br>Spade lug<br>connection<br>6mm Wire<br>Toolless Clamp Lug and<br>Ganging of open bus bar<br>Multiple connection<br>Poles (#4 to #18)<br>Toolless DIN Rail<br>Mounting Wire Strip<br>Length<br>Indicator<br>**----- End of picture text -----**<br>
## **Multi-Pole Ganging**
Use multi-pole connection kit part number JV-L to gang multiple poles together. One JV-L kit is sufficient to gang up to 4 poles.
**For additional information see reorder #3185**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**275**
**Fuse Holders and Blocks**
## **Rail Mount Fuse Blocks and Holders**
## **Dimensional Data - mm (in)**
**==> picture [89 x 233] intentionally omitted <==**
**----- Start of picture text -----**<br>
61.83<br>[ 2.434 ]<br>18.59<br>[ 0.732 ] —————<br>\<br>\<br>42.58<br>[ 1.676 ]<br>52.83<br>[ 2.080 ]<br>83.19<br>[ 3.275 ]<br>**----- End of picture text -----**<br>
**==> picture [176 x 164] intentionally omitted <==**
**----- Start of picture text -----**<br>
70<br>[ 2.756 ]<br>52.5<br>[ 2.067 ]<br>35<br>[ 1.378 ]<br>17.5<br>[ 0.689 ]<br>p e ppp<br>]<br>73.88 [ 2.909<br>**----- End of picture text -----**<br>
**==> picture [40 x 67] intentionally omitted <==**
**----- Start of picture text -----**<br>
7.0<br>[ 0.276 ]<br>9<br>[ 0.354 ]<br>**----- End of picture text -----**<br>
## **Removing Instructions**
**==> picture [116 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
1. Press down on top<br>of DIN-Rail<br>~~<br>2. Rotate out<br>on the bottom<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**276**
**Fuse Holders and Blocks**
## **Global Modular Fuse Holders**
PV UL IEC Class J 30A 8x32 IEC 14x51 IEC 22x58 IEC
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|
|---|---|---|---|---|---|---|---|---|---|
|Without<br>Indication|With*<br>Indication|Size|Max<br>Voltage<br>& Current|IEC|UL|Phase Configuration|No. of<br>17.5mm<br>Modules|Wire Range|Maximum Torque|
|CH081D<br>CH081DNX|CH081DI<br>-|CH08<br>8x32|IEC<br>400Vac<br>25A|•<br>•||1-pole<br>1 Neutral Pole|1<br>1|1-16mm2 (18-8 AWG)|2.5 N•m (22LB-In)|
|CH081DNS|CH081DNSI|||•||1-pole + Neutral|1|1-10mm2 (18-8 AWG)|2.0 N•m (17.5LB-In)|
|CH081DN<br>CH082D<br>CH083D<br>CH083DNS<br>CH083DN<br>CH084D|CH081DNI<br>CH082DI<br>CH083DI<br>CH083DNSI<br>CH083DNI<br>CH084DI|||•<br>•<br>•<br>•<br>•<br>•||1-pole + Neutral<br>1-pole + Neutral<br>2-pole<br>3-pole<br>3-pole + Neutral<br>3-pole + Neutral<br>4-pole|2<br>2<br>3<br>3<br>4<br>4|(18-8 AWG)<br>1-16mm2 (18-8 AWG)|2.0 N•m (17.5LB-In)<br>2.5 N•m (22LB-In)|
|CHM1DU<br>CHM2DU<br>CHM3DU<br>CHM4DU<br>CHM1DNU<br>CHM3DNU|CHM1DIU<br>CHM2DIU<br>CHM3DIU<br>CHM4DIU<br>CHM1DNIU<br>CHM3DNIU|CHM<br>10X38<br>and<br>Midget|UL<br>600V/30A;<br>IEC<br>690V/32A|•<br>•<br>•<br>•<br>•<br>•<br>•<br>•|*<br>*<br>*<br>*<br>*<br>*<br>*|1-pole<br>2-pole<br>3-pole<br>4-pole<br>1-pole + Neutral<br>3-pole + Neutral<br>1-pole<br>1-pole + Neutral|1<br>2<br>3<br>4<br>2<br>4<br>1<br>2|1-21mm2 (18-4 AWG)|3.4 N•m (30LB-In)|
|–|CHM1DI-48U||UL 48Vdc/30A;<br>IEC<br>48Vdc/32A|||||||
|CHM1DNXU|–||IEC 690V32A|||||||
|CHPV1U<br>CHPV2U|CHPV1IU<br>CHPV2IU|CHPV|UL & IEC;<br>1000Vdc/30A|•<br>•|†††<br>†††<br>**<br>**<br>**<br>**|1-pole<br>2-pole<br>1-pole<br>2-pole<br>3-pole<br>1-pole|1<br>2<br>1<br>2<br>3<br>1|1-21mm2 (18-4 AWG)|3.4 N•m (30LB-In)|
|CHCC1DU<br>CHCC2DU<br>CHCC3DU|CHCC1DIU<br>CHCC2DIU<br>CHCC3DIU|CHCC<br>Class CC|UL<br>600V/30A|||||||
|CHCC1DI-48U|–||UL 48Vdc/30A|||||||
|CH141D<br>CH141DMS<br>CH141DNX<br>CH141DN<br>CH142D<br>CH143D<br>CH143DMS<br>CH143DN<br>CH143DNMS<br>CH144D|CH141DI<br>-<br>-<br>CH141DNI<br>CH142DI<br>CH143DI<br>-<br>CH143DNI<br>-<br>CH144DI|CH14<br>14x51|UL<br>600Vac/dc<br>40A<br>(5 Watt)<br>IEC<br>690Vac,<br>50A|•<br>•<br>•<br>•<br>•<br>•<br>•<br>•<br>•<br>•|†<br>†|1-pole<br>1-pole + Microswitch<br>1 Neutral Pole<br>1-pole + Neutral<br>2-pole<br>3-pole<br>3-pole + Microswitch<br>3-pole + Neutral<br>3-pole + Neutral + Microswitch<br>4-pole|1.5<br>1.5<br>1.5<br>3<br>3<br>4.5<br>4.5<br>6<br>6<br>6|2.5-16mm2 (14-6 AWG)|3.0 N•m (26LB-In)|
|CH221D<br>CH221DMS<br>CH221DNX<br>CH221DN<br>CH222D<br>CH223D<br>CH223DMS<br>CH223DN<br>CH223DNMS<br>CH224D|Not<br>Available<br>with<br>local<br>neon<br>indication<br>(remote<br>microswitch<br>only)|CH22<br>22x58|UL<br>600Vac/dc,<br>100A<br>(9.5 Watt)<br>IEC<br>690Vac,<br>125A|•<br>•<br>•<br>•<br>•<br>•<br>•<br>•<br>•<br>•|†<br>†<br>†<br>†|1-pole<br>1-pole + Microswitch<br>1 Neutral Pole<br>1-pole + Neutral<br>2-pole<br>3-pole<br>3-pole + Microswitch<br>3-pole + Neutral<br>3-pole + Neutral + Microswitch<br>4-pole|2<br>2<br>2<br>4<br>4<br>6<br>6<br>8<br>8<br>8|2.5-50mm2 (14-1 AWG)|4.0 N•m (35LB-In)|
|**Class J**<br>_easy_ID™ Indication|Neon<br>Indication|||||||||
|CH30J1<br>CH30J2<br>CH30J3|CH30J1I<br>CH30J2I<br>CH30J3I|CH30J<br>30A<br>Class J|UL/CSA<br>600Vac||††<br>††<br>††|1-pole<br>2-pole<br>3-pole|—<br>—<br>—|1-50mm2 (18-1 AWG)|1-8 AWG 4.0 N•m (35LB-In)<br>10-18 AWG 2.7N•m (24LB-IN)|
|CH60J1<br>CH60J2<br>CH60J3|CH60J1I<br>CH60J2I<br>CH60J3I|CH60J<br>60A<br>Class J|UL/CSA<br>600Vac||††<br>††<br>††|1-pole<br>2-pole<br>3-pole|—<br>—<br>—|1-50mm2 (18-1 AWG)|1-8 AWG 4.0 N•m (35LB-In)<br>10-18 AWG 2.7N•m (24LB-In)|
|† UL Recognized (cURus)<br>†† UL LIsted (cULus)<br>††† UL Recognized, Standard 4248-18, CSA<br>For further details see Data Sheets 2053 (CH08, CHM, CHCC, CH14 AND CH22) and 2144 (CHJ Class J)<br>*90V miminum required for illumination<br>***12V mininum required for illumination||||||||||
- UL Recognized (cURus) †† UL LIsted (cULus) ††† UL Recognized, Standard 4248-18, CSA For further details see Data Sheets 2053 (CH08, CHM, CHCC, CH14 AND CH22) and 2144 (CHJ Class J)
- *90V miminum required for illumination
- ***12V mininum required for illumination
**For additional information see reorder #3185**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**277**
**Fuse Holders and Blocks**
## **Global Modular Fuse Holders - Remote Fuse Monitoring Accessory CH-PLC**
## **Make it Simple with Bussmann resettable**
**three-phase remote fuse monitor that integrates with a Programmable Logic Controller (PLC) or other monitoring and control equipment.**
## **Specifications:**
- **Power Input** : 24Vdc / 5mA
- **Sensing Voltage** : 600V/30mA
- **Output Signals** : Digital 0Vdc (Low), 24Vdc (High)
- 0Vdc Low – Fuse is good
- 24Vdc High – Fuse has opened
- When the fuse opens, the output signal is sent high and will remain high until the unit is reset
- **Rated Impulse Voltage** : 8kV
- **Local Indication** : Two distinct LEDs indicate unit power (green) and open fuse (red). Upon the replacement of the fuse, the actuation of the reset switch will reset the open fuse LED
- **Flammability Rating** : UL 94V0
## **Wiring:**
- For power, signal and ground connections use 22-24AWG (0.25mm[2] ) 300V rated wire
## **Emissions and Immunity Testing:**
- Electrostatic Discharge IEC 61000-4-2
- Electrical Fast Transient/Burst IEC 6100-4-4
- Surge Immunity IEC61000-4-5
## **Packaging:**
- The CH-PLC is packaged individually
- A single unit monitors up to three phases
- Package includes 0.11” (2.8mm) quick connects for power, signal and ground connections
## **Minimum Circuit Voltage:**
- Minimum circuit voltage required across the CH holder is 100Vac for the remote indication device to operate
## **Installation Technique:**
- Mounts on the left side of the fuse holder and mechanically interlocks with the fuse holder switch handle with hardware provided
## **IP20 Rating:** Yes
## **Environmental Data:**
- Storage and Operating Temperature: -20°C to 75°C
## **Agency Information:**
- UL 508
- cULus to CSA Standard 22.2 No.14
## **PLC Programming:**
- The CH-PLC signal line is designed to provide a digital input to a PLC I/O card.
- Programmable Logic Control program must be written to properly interpret the input signal to the PLC.
- The PLC program should check for consecutive high signals before taking action on a critical process.
_**De-energize all circuits before installing or removing any CH-PLC devices and follow all prescribed safety procedures.**_ **For additional information see reorder #3185**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**278**
**Fuse Holders and Blocks**
## **Global Modular Fuse Holders - Comb-Bus Bar Specifications and Selection Guide**
## **Specifications**
**Agency Information:** UL 508, File E195399 **Pitch:** 17.8mm
**SCCR:** 10kA (default)
100kA (with upstream Class J 200A fuses)
**Max Current:** 100A (power feed from end; 200A (power feed from center)
**Max Voltage:** 600Vac/dc (three phase)
1000Vdc/600Vac (single phase)
## **Features and Benefits**
- Easily distribute power in single-phase or three-phase configurations
- Flexible cut-to-length solutions without compromising on the product’s finger-safe features
- 100kA SCCR (Short-Circuit Current Rating) when protected by a 200A Class J fuse
- Single-phase bus bars rated to 1000Vdc and 100A in end-fed configuration (200A for center-fed configuration)
- Three-phase bus bars rated to 600Vac/dc and 100A in end-fed configuration (200A for center-fed configuration)
- Power feed terminals for single-phase and three-phase service
## **Selection Guide**
|Part Number|Description|
|---|---|
|BB1P100M3|Single-phase 1000Vdc busbar, 100A, 3 pins, assembled endcap|
|BB1P100M6|Singlephase 1000Vdc busbar, 100A, 3 pins, assembled endcap<br>Single-phase 1000Vdc busbar, 100A, 6 pins, assembled endcap|
|BB1P100M9|Singlephase 1000Vdc busbar, 100A, 6 pins, assembled endcap<br>Single-phase 1000Vdc busbar, 100A, 9 pins, assembled endcap|
|BB1P100M12|Singlephase 1000Vdc busbar, 100A, 9 pins, assembled endcap<br>Single-phase 1000Vdc busbar, 100A, 12 pins, assembled endcap|
|BB1P100M15|Singlephase 1000Vdc busbar, 100A, 12 pins, assembled endcap<br>Single-phase 1000Vdc busbar, 100A, 15 pins, assembled endcap|
|BB1P100M57|Singlephase 1000Vdc busbar, 100A, 15 pins, assembled endcap<br>Single-phase 1000Vdc cuttable busbar, 100A, 57 pins, without endcap|
|BB3P100M6|Singlephase 1000Vdc cuttable busbar, 100A, 57 pins, without endcap<br>Three-phase 600V busbar, 100A, 6 pins, assembled endcap|
|BB3P100M9|phase 600V busbar, 100A, 6 pins, assembled endcap<br>Three-phase 600V busbar, 100A, 9 pins, assembled endcap|
|BB3P100M12|phase 600V busbar, 100A, 9 pins, assembled endcap<br>Three-phase 600V busbar, 100A, 12 pins, assembled endcap|
|BB3P100M15|phase 600V busbar, 100A, 12 pins, assembled endcap<br>Three-phase 600V busbar, 100A, 15 pins, assembled endcap|
|BB3P100M57|phase 600V busbar, 100A, 15 pins, assembled endcap<br>Three-phase 600V cuttable busbar, 100A, 57 pins, without endcap|
|ECAP1P|phase 600V cuttable busbar, 100A, 57 pins, without endcap<br>Single-phase busbar endcap|
|ECAPMP|Singlephase busbar endcap<br>Three-phase busbar endcap|
|PWR35MM|phase busbar endcap<br>35mm2 feeder terminal for three-phase busbar (115A, 1000Vac/dc)|
|FSCVR|phase busbar (115A, 1000Vac/dc)<br>Spare contact safety protection covers|
|PWR1PLP|Spare contact safety protection covers<br>Single-phase low-profile feeder terminal (115A, 1000Vac/dc)|
|PWR50MM|Singlephase lowprofile feeder terminal (115A, 1000Vac/dc)<br>50mm2 direct feed terminal (1000Vac/dc)|
## **For additional information see reorder #3185**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**279**
**Fuse Holders and Blocks**
## **Global Modular Fuse Holders - Comb-Bus Bar Features and Installation Guide**
## **Typical Installation Example**
**==> picture [98 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power Feed Terminals<br>Comb-Bus Bar<br>Modular Fuse Holders<br>**----- End of picture text -----**<br>
**==> picture [438 x 306] intentionally omitted <==**
**----- Start of picture text -----**<br>
Typical Dimensional Data<br>Three-phase Single-phase<br>JUUU Ts eT oe<br>ECAP1P ECAPM P FSCV R P W R 1 PLP<br>Mt URS fy<br>. Na t | a A<br>PWR35MM PWR50MM<br>**----- End of picture text -----**<br>
**==> picture [184 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
For additional information see reorder #3185<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/D ~~a~~ tasheetsEle
**280**
**Fuse Holders and Blocks** a
## **Class J Modular Fuse Holders**
## **CH _ _ J _**
## **Specifications**
**Description:** IP20 finger-safe, 1- to 3-pole Class J fuse holder with DIN-Rail or panel mounting.
## **Ratings:**
Volts: — 600Vac/dc (or less) Amps: — 30A (30A version) — 60A (60A version) SCCR: — 200kA **Wire Range:** Cu solid and stranded conductors with single (1-18AWG) and dual (3-18AWG) wire ratings. See Catalog Numbers table for details. **Torque Rating:** 10-18AWG 24 lb-in. 1-8AWG 35 lb-in.
**Poles:** 1-, 2- or 3-Pole.
## **Storage & Operating Temperature Range*:**
- -20°C to 75°C.
**Agency Information:** CE, UL 4248/CSA 22.2 No. 4248.P UL Listed, Guide IZLT, File E14853.
**Flammability Rating:** UL 94V0.
**30 Amp Version**
## **60 Amp Version**
## **Catalog Numbers**
See Catalog Numbers table below.
## **Features and Benefits**
- Choice of local fuse indication; _easy_ ID™ viewing window (for seeing indicator on LPJ-SPI indicating fuse) or neon lamp.
- Versatile 1-, 2- and 3-pole versions for 0-30A and 35-60A fuses with dual wire rated connections simplify wiring.
- Improved electrical safety with IP20 finger-safe construction with lock-out/tag-out feature. 3-phase fuse extraction assures all phases are opened for service work.
## **Dimensions (mm):**
|**Fuse Size**|**Poles**|**W**|**D**|**H**|
|---|---|---|---|---|
|0-30A|1|32|70|115|
||2|64|70|115|
||3|96|70|115|
|35-60A|1|40|83|125|
||2|80|83|125|
||3|120|83|125|
- Flexible panel/35mm DIN-Rail mounting mounting options
- *For fuse selection on applications above or below 25ºC, consult derating charts in Bussmann publication “Selecting Protective Devices” (SPD).
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**# of**<br>**Poles**|**Local**<br>**Indication**|**Amp**<br>**Rating**|**Volts**<br>**(AC/DC) **|**IP20**<br> **Finger-Safe **|**AWG Single**<br> **Wire Range**|**Padlockable**|**Mounting**|
|---|---|---|---|---|---|---|---|---|
|CH30J1<br>CH30J1I<br>CH30J2<br>CH30J2I<br>CH30J3<br>CH30J3I|1<br>1<br>2<br>2<br>3<br>3|_easy_ID**<br>Neon Lamp***<br>_easy_ID**<br>Neon Lamp***<br>_easy_ID**<br>Neon Lamp***|30|600|Yes|1-18|Yes|35mm DIN/ Panel|
|CH60J1<br>CH60J1I<br>CH60J2<br>CH60J2I<br>CH60J3<br>CH60J3I|1<br>1<br>2<br>2<br>3<br>3|_easy_ID**<br>Neon Lamp***<br>_easy_ID**<br>Neon Lamp***<br>_easy_ID**<br>Neon Lamp***|60|600|Yes|1-18|Yes|35mm DIN/ Panel|
** _easy_ ID™ viewing window, requires use of Bussmann LPJ_SPI permanent indication fuses.
- *** Indication non-fuse dependent, minimum voltage 90Vac/115Vdc.
**Data Sheet: 2144**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**281**
**Fuse Holders and Blocks**
## **Optima[™] Fuse Holder Module and Disconnect Switch**
## **OPM-1038 With Disconnect Switch**
## **Features/Benefits**
- Padlockable with finger-safe terminals for safety. Qualified as IP20 per IEC 60529.
- Cam-action handle for easy module removal, offered with Class CC rejection clips or European 10 x 38mm clips to meet global needs
- Wire ready with 35mm DIN-Rail or screw panel mounting (#8 screw, 1[1] ⁄4” long) saves installation time
- Fuse indication lights with option for remote fuse status available. See Data Sheet for additional wiring details.
## **Typical Applications**
## **Catalog Number Build-A-Code**
Communication
Series Fuse Type Communication **O P M - 1 0 3 8 S W** Moo =86ooo **Blank** = 10 x **C** = 38mm or[13] ⁄32” x 1-[1] ⁄2” Communication Feature **R** = Class CC
## **Specifications**
**Description:** 3-pole load break modular fuse holder and disconnect switch for[13] ⁄32 x 1[1] ⁄2˝ (10 x 38mm) fuses. **Dimensions:** See Dimensions illustration.
**Poles:** 3
**Agency Information:** CE, UL (see table), CSA Certified, C22.2 No. 39, Class 6225-01, File 47235, IEC (see table). **Flammability Rating:** UL 94V0.
|**Horsepower Rating of Switch**<br>Volts<br>240<br>480<br>3-Phase<br>HP<br>5<br>10<br>**Recommended Fuse Types**<br>**Class CC**<br>**Midget (Non-Rejection)**<br>~~Bo~~|600<br>15<br>**European**|600<br>15<br>**European**|
|---|---|---|
|LP-CC<br>KTK||C10M|
|KTK-R<br>FNM||C10G|
|FNQ-R<br>FNQ|||
- Industrial Control
- Process Control Systems
- Automated Warehouse Systems
- Individual Control Circuits
## **Dimensions**
**==> picture [241 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.72∑ ( ± .045)<br>(145.3mm) (± 1.14)<br>4.25∑ ( ± 0.03)<br>(35.0mm) = 1.38∑ (10.9mm) ( 0.43∑ ( ± 0.03) ± 0.76) r 2T14T 26T3 (108.0mm) ( — ± 0.76) 1L13L25L3 CommunicationPort0.740.27∑∑ (18.8mm)(6.9mm) (44.7mm) 1.76∑<br>0.31∑ (7.9mm)<br>0.57∑ ( ± 0.03)<br>(14.5mm) (± 0.76)<br>(95.0mm) ( 3.74∑ ( ±± 0.03) 0.76)<br>(80.5mm) 3.17∑ (5.8mm) 0.23∑ CommunicationPort0.50∑ (12.7mm)<br>0.44∑ (11.2mm)<br>(5.6mm) 0.224∑ (33.3mm) (1.312 ± 0.01)∑ Panel MountingHole Pattern(47.2mm) 1.86∑<br>= Panel MountingHole Pattern(± 0.25) — (91.4mm) 3.60∑ —J<br>BUSS<br>**----- End of picture text -----**<br>
## **Physical Characteristics**
- Small size matches 45mm IEC starter width
- Accepts #8-18 AWG stranded, #10-18 AWG solid wire
- 3-pole
- Handle and shaft required for through the door operation
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Electrical Rating**|**SCCR****<br>**Rating**|**Clips**|**Remote Open**<br>**Fuse Indication**|**UL Information**<br>**Std.**|**File**|**Guide**|**IEC**|**CE**|
|---|---|---|---|---|---|---|---|---|---|
|OPM-1038SW|30A, 600Vac UL/CSA<br>32A, 660Vac IEC|*|Non-rejection,<br>10x38mm or<br>13⁄32”x 11⁄2”|No|Recognized<br>UL 508|E161278|NLRV2|IEC 60947-3|Yes|
|OPM-1038RSW|30A, 600Vac UL/CSA|100kA|Rejection,<br>Class CC|No|Listed<br>UL 508|E161278|NLRV||Yes|
|OPM-1038SWC|30A, 600Vac UL/CSA<br>32A, 660Vac IEC|*|Non-rejection,<br>10x38mm or<br>13⁄32”x 11⁄2”|Yes|Recognized<br>UL 508|E161278|NLRV2|IEC 60947-3|No|
|OPM-1038RSWC|30A, 600Vac UL/CSA|100kA|Rejection,<br>Class CC|Yes|Listed<br>UL 508|E161278|NLRV||No|
*Rating varies depending on fuse used in module; 100kA maximum
**Short-Circuit Current Rating
## **Data Sheet: 1103**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**282**
**Fuse Holders and Blocks** Ba
## **Optima[™] Fuse Holder Module**
## **OPM-1038**
## **Features/Benefits**
- Padlockable with finger-safe terminals for safety. Qualified as IP20 per IEC 529.
- Cam-action handle for easy module removal.
- Offered with Class CC rejection clips or European 10 x 38mm clips to meet global needs
- Wire ready with 35mm DIN-Rail or screw panel mounting (#8 screw, 1[1] ⁄4˝ long) saves installation time
- Fuse indication lights with option for remote fuse status indication. See Data Sheet for additional wiring details.
## **Catalog Number Build-A-Code**
## **Typical Applications**
- Industrial Control
Series Fuse Type Communication
**==> picture [117 x 21] intentionally omitted <==**
**Blank** = 10 x C = 38mm or Communication 13⁄32˝ x 1 1⁄2˝ Feature **R** = Class CC
## **Specifications**
**Description:** 3-pole modular fuse holder for[13] ⁄32” x 1[1] ⁄2” (10 x 38mm) fuses.
**Dimensions:** See Dimensions illustration.
**Poles:** 3
**Agency Information:** CE, UL (see table), CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235, IEC (see table).
**Flammability Rating:** UL 94V0.
## **Recommended Fuse Types**
**Class CC Midget (Non-Rejection) European** LP-CC KTK C10M KTK-R FNM C10G FNQ-R FNQ
## **Physical Characteristics**
- Small size matches 45mm IEC starter width
- Accepts #8-18 AWG stranded, #10-18 AWG solid wire
- 3-pole
- Process Control Systems
- Automated Warehouse Systems
- Individual Control Circuits
## **Dimensions**
**==> picture [241 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.22∑ ( ± 0.03)<br>(81.8mm) (± 0.76)<br>2T1 Communication<br>IL1 Port<br>(44.7mm) 1.76∑ ( a ± 0.03) (± 0.7 )4T2 -_ 3L2 0.27∑ (6.9mm)<br>6T3 5L3 0.74∑ (18.8mm)<br>0.31∑ (7.9mm)<br>3.60∑ ( ± 0.03)<br> (91.4mm) (± 0.76)<br>0.57 “o ∑ t k<br>(14.5mm)<br>ety<br>3.74∑ ( ± 0.03) 3.17∑<br>(95.0mm) (80.5mm)<br>(± 0.76) Communication<br>Port<br>(41.9mm) 1.65∑ ( ± 0.03) (± 0.76) o |e ee (5.8mm) 0.23∑ b be 0.50∑ (12.7mm)<br>AR 0.44∑ (11.2mm)<br>(5.6mm)0.224" (1.312 ± 0.0∑1) (91.4mm) 3.60∑ ( ± 0. (± 03) 0.76)<br>(33.3mm)(± 0.25) 1.86∑ ( ± 0.03)<br>Panel Mount (47.2mm)<br>Hole Pattern (± 0.76)<br>Panel Mount<br>ry pe Hole Pattern<br>BUSS<br>**----- End of picture text -----**<br>
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Electrical Rating**|**SCCR****<br>**Rating**|**Clips**|**Remote Open**<br>**Fuse Indication**|**UL Information**<br>**Std.**|**File**|**Guide**|**IEC**|**CE**|
|---|---|---|---|---|---|---|---|---|---|
|OPM-1038|30A, 600Vac/dc UL/CSA<br>(Max 3 Watts per fuse)<br>32A,660V IEC|*|Non-rejection,<br>10 x 38mm or<br>13⁄32˝ x 11⁄2˝|No|Recognized<br>UL 4248|E14853|IZLT2|IEC 60269-2-1|Yes|
|OPM-1038R|30A, 600Vac/dc UL/CSA|200kA|Rejection,<br>Class CC|No|Listed<br>UL 4248|E14853|IZLT||Yes|
|OPM-1038C|30A, 600Vac/dc UL/CSA<br>(Max 3 Watts per fuse)<br>32A,660V IEC|*|Non-rejection,<br>10 x 38mm or<br>13⁄32˝ x 11⁄2˝|Yes|Recognized<br>UL 4248|E14853|IZLT2|IEC 60269-2-1|No|
|OPM-1038RC|30A, 600Vac/dc UL/CSA|200kA|Rejection,<br>Class CC|Yes|Listed<br>UL 4248|E14853|IZLT||No|
*Rating varies depending on fuse used in module; 200kA maximum.
**Short-Circuit Current Rating
**Data Sheet: 1102**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**283**
**Fuse Holders and Blocks**
## **Optima[™] Three-pole Overcurrent Protection Module**
**Fuse Holder Wire Range:** — 75°Cu Only — #18-12 Single/Dual, torque 15lb-in — #10-8 Single/Dual, torque 20lb-in — Dual wire with same gauge and type
## **OPM-NG-**
— 75°Cu Only — #18-12 Single/Dual, torque 15lb-in — #10-8 Single/Dual, torque 20lb-in — Dual wire with same gauge and type 75 ~~AWu~~ º Cu Only ~~[mm2] (N•m)/lb-in~~ AWG [mm2] (N•m)/lb-in SolidSolid #18-8 x 1#18-8 x 11-6 x 11-6 x 1 18-12 Single/Dual18-12 Single/Dual #18-8 x 2#18-8 x 21-6 x 21-6 x 2Strld15lb-in (1.7 N#18-8 x 1•m) 1-6 x 1Stranded #18-8 x 1 1-6 x 1 #18-8 x 2#18-8 x 21-6 x 21-6 x 2 10-10-8 Sin8 Single/Dualgle/Dual FerFe **r** rulesules 1-4 x 11-4 x 1 20lb-20 **in** (2.5 N•m)-lb (2.5 N•m) **Specifications** ~~2°~~ 1-4 x 21-4 x 2 **Description: Input Power Terminal Wire Range: OPM-NG-SC3:** 3-pole Class CC fuse holder for use with **Wiring** Solid (1) #14 to #2 (1.5 to 25mm[[2]] ) conductor or Class CC fuses (Bussmann Types LP-CC, Conductor (2) #14 to #6 (1.5 to 10mm[[2]] ) conductors FNQ-R, KTK-R). Stranded (1) #14 to #2 (1.5 to 25mm[[2]] ) conductor or
## **Specifications Description:**
**Wiring** Solid (1) #14 to #2 (1.5 to 25mm[[2]] ) conductor or Conductor (2) #14 to #6 (1.5 to 10mm[[2]] ) conductors Stranded (1) #14 to #2 (1.5 to 25mm[[2]] ) conductor or Conductor (2) #12 to #6 (2.5 to 10mm[2] ) conductors **Tightening** Connector 20lb-in (2.2 N•m) ~~——~~ **Torque:** Screw Clamp 15lb-in (1.7 N•m) **Materials:** — **Housing:** Thermoplastic - ULV2
- **OPM-NG-SM3:** 3-pole fuse holder for use with[13] ⁄32˝ x 1[1] ⁄2˝ and 10.3 x 38mm fuses (Bussmann Types: 13⁄32˝ x 11⁄2˝; KTK, FNQ, KLM, 10 x 38mm; FWA, FWC, C10G_ _, C10M_ _).
## **Ratings:**
- **Clip:** Tin-plated copper alloy
Volts: — OPM-NG-SC3: 600Vac (or less)
- **Contact lubricant:** Fluoroether grease
- OPM-NG-SM3: 600Vac (or less) UL and CSA 30A
- **Saddle screw:** Plated steel
- OPM-NG-SM3: 690Vac (or less) IEC 32A
- **DIN rail springs:** Stainless steel
- Amps: — OPM-NG-SC3: 0-30A
- OPM-NG-SM3: 0-30A
## **Optional Accessories:**
SCCR:— OPM-NG-SC3: 200kA
— OPM-NG-SM3: Same as fuse IR, 200kA maximum **Agency Information:** CE, UL; OPM-NG-SC3 UL Listed, UL 4248, File E14853, Guide IZLT. OPM-NG-SM3, UL Recognized, UL 4248, File E14853, Guide IZLT2. CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235. IEC 60947-3 Utilization Category AC20B.
**Handling & Storage Temperature:** -10° to 65°C.
## **Features/Benefits**
- 45mm width matches IEC starters
- 35mm DIN-Rail or panel mounting feature. Maximum screw size #8 (M4)
- Pressure plate terminations with dual-wire rated terminals (see Wire Table) and optional auxiliary contacts
- Integrated collapsible handle and fuse carrier cannot be removed from holder base
- Padlockable and IP20 finger-safe to IEC60529
## **Typical Applications**
- Mass Produced Control Systems
## **Comb Bar (Max current rating = 63A)**
GV2G245A46 2 circuit, 45mm between same phases GV2G254A46 2 circuit, 54mm between same phases GV2G272A46 2 circuit, 72mm between same phases GV2G345A46 3 circuit, 45mm between same phases GV2G354A46 3 circuit, 54mm between same phases GV2G445A46 4 circuit, 45mm between same phases GV2G454A46 4 circuit, 54mm between same phases GV2G472A46 4 circuit, 72mm between same phases GV2G554A46 5 circuit, 54mm between same phases
## **Input Terminal Block (Max current rating = 63A)**
GV2G05 Input/Feed Through Power Terminal, Supports feed through to another system, DIN-Rail mount only GVG09 Input Power Terminal
## **Cover**
|**Cover**||
|---|---|
|GV1G10|Protective Cover for unused terminals on comb bar|
|**Auxiliary Contacts**<br>GVAE11|**Contacts**<br>NO/NC|
|GVAE20|NO/NO|
- Process Control Systems
- Automated Warehouse Systems
- Individual Control Circuits
**Data Sheet: 1109**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**284**
**Fuse Holders and Blocks**
## **Optima[™] Three-pole Overcurrent Protection Module**
**==> picture [99 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Optional Accessories<br>**----- End of picture text -----**<br>
**Dimensions** - mm (± 0.38) / in (± .015)
**Data Sheet: 1109**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**285**
**Fuse Holders and Blocks**
## **Class J (Finger-safe) Fuse Holders**
## **Safety J™ — JT(N)60030 & JT(N)60060**
## **Specifications**
**Description:** Indicating and non-indicating finger-safe, DIN-Rail mount fuse holders for use with Class J fuses - (Bussmann LPJ, JKS).
**Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts: — 600Vac
Amps: — 0-60A (JT(N)60060)
- 0-30A (JT(N)60030)
SCCR:— 200kA RMS Sym.
- 300kA self certified using Bussmann LPJ_SP fuses
**Agency Information:** CE, Listed to UL 4248: Guide IZLT, File 14853, CSA Certified: Class 6225-01, File 47235. IP20 per IEC 60529.
**30 Amp Version**
**60 Amp Version**
## **Flammability Rating:** UL 94V0.
**Indication:** Min voltage: 90Vac, 115Vdc; neon lamp “ON” when fuse opens, voltage source and current path are present.
**Terminations:** 30A dual port torque 20lb-in, 60A single port torque 45lb-in, terminal construction, tin-plated copper alloy.
**Wire Size:** JT(N)60030 - rated for 75°C, AWG#18-#8; Cu only, JT(N)60060 - rated for 75°C, AWG#14-#4; Cu only.
(Note: For JT(N)60030 use both stranded or solid, in a variety of dual wire combinations of same wire size and type.)
## **Features and Benefits**
- Short-Circuit Current Rating of 300kA with Bussmann LPJ___SP fuses.
- Rapid, flexible 35 mm DIN-Rail mounting.
- One piece interlocking design for assembling multiple pole blocks reduces inventory costs.
- Removable fuse carrier allows fuse replacement away from base while maintaining finger-safe rating.
## **Typical Applications**
- Industrial Controls
- Process Controls
- Small HP VFDs
## **Catalog Numbers**
|**Catalog Numbers**|**Amps**|**Indication**|
|---|---|---|
|JT60030|30|Non-indicating|
|JT60060|60|Non-indicating|
|JTN60030|30|Indicating (Neon)|
|JTN60060|60|Indicating (Neon)|
## **Data Sheet: 1152**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**286**
**Fuse Holders and Blocks** a
## **Class J (Finger-safe) Fuse Holders**
## **Dimensions for JT60030 & JTN60030 — in (mm)**
**==> picture [426 x 209] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.14 1.05<br>(29.0) (26.7) BUSS BUSS BUSS<br>JT60030 JT60030 JT60030<br>Slot Din-rail 600VAC0 – 30A 600VAC0 – 30A 600VAC0 – 30A<br>USE CLASS J USE CLASS J USE CLASS J<br>FUSES FUSES FUSES<br>[nel .07 —— DO NOT REMOVEUNDER LOAD DO NOT REMOVEUNDER LOAD DO NOT REMOVEUNDER LOAD<br>(1.8) 1.23<br>1 pole<br>Shown without fuse MOUNTING (69.9)2.75 — 2 pole (31.2) (61.3)2.42<br>pullout cover 3 pole 3.60<br>(91.4)<br>a a =I<br>2.52<br>(64.1)<br>Leo ee<br>**----- End of picture text -----**<br>
## **Dimensions for JT60060 & JTN60060 — in (mm)**
**==> picture [432 x 232] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.31 1.25 BUSS BUSS BUSS<br>(33.3) (31.8) JT60060 JT60060 JT60060<br>Slot freq, | Din-rail fSTaleat USE CLASS J600VAC35 – 60A USE CLASS J600VAC35 – 60A USE CLASS J600VAC35 – 60A<br>FUSES FUSES FUSES<br>DO NOT REMOVEUNDER LOAD DO NOT REMOVEUNDER LOAD DO NOT REMOVEUNDER LOAD<br>e .10 ip<br>3.10 (2.6) 1 pole (38.1)1.52<br>(78.7) 2 pole 2.96<br>(75.2)<br>MOUNTING 3 pole 4.40<br>(111.7)<br>Shown without fuse<br>pullout cover a a = ed<br>3.06<br>orl [0 f) (77.7) HsAATHyi<br>**----- End of picture text -----**<br>
JT(N)600 Series fuse blocks can be dovetailed together within the same current rating to provide multiple pole block configurations.
NOTE: JT(N)60030 cannot be dovetailed to JT(N)60060.
**Data Sheet: 1152**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**287**
**Fuse Holders and Blocks**
## **SAMI™ Fuse Covers**
## **SAMI™Series**
**==> picture [244 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
SAMI-1I SAMI-2I SAMI-3I SAMI-4I<br>a WW<br>SAMI-6I SAMI-7I SAMI-8I<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Indicating and non-indicating fuse covers for Class J, RK1, RK5, H, K5, CC, G (0-30A) and midget-type fuses. Indicating feature requires a minimum of 90Vac or 115Vdc to illuminate lamp. One cover required for each pole. **WARNING:** To avoid electrical shock, turn power off before installing, removing or servicing.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — Non-Indicating - 0-600Vac/dc — Indicating - 90 to 600Vac -115 to 600Vdc
Amps: — 0-100A
**Agency Information:** CE, UL Listed; SAMI-1I through SAMI-6I, SAMI-8I and SAMI-9I, SAMI-1N through SAMI-6N, SAMI-8N and SAMI-9N, UL Recognized; Guide JDVS2, File E58836, SAMI-7I and SAMI-7N, CSA Certified, File LR47235-93C.
## **Catalog Numbers**
|**Catalog**<br>**Numbers***|**Description**|**Dimensions - in**<br>**A**<br>**B**|**Dimensions - in**<br>**A**<br>**B**|**C**|
|---|---|---|---|---|
|SAMI-1_|600V, J (0-30A) and 600V, T (35-60A)**|5.02|1.03|1.94|
||250V, RK, K5, H (35-60A)||||
|SAMI-2_|600V, RK, K5, H(0-30A)|7.03|1.30|2.07|
|SAMI-3_|600V, J(65-100A)|7.03|1.30|2.33|
|SAMI-4_|250V,RK,K5,H(65-100A)|8.20|1.30|2.18|
|SAMI-5_|600V,RK,K5,H(35-60A)|8.20|1.30|2.18|
|SAMI-6_|600V, J(35-60A)|4.98|1.17|2.14|
|SAMI-7_|600V, Midget, Class CC, G(0-30A)|3.82|0.75|1.72|
|SAMI-8†_|600V,RK††,K5,H(65-100A)|10.38|1.50|2.33|
|SAMI-9_|250V, RK, K5, H (0-30A) and 600V,|3.82|0.75|1.72|
||T (0-30A)||||
## **Features and Benefits**
- Insulated cover allows field conversion of fuses mounted in open fuse blocks to dead front configuration.
- Optional open fuse indicating light aids in system troubleshooting.
- Units are re-usable.
- Allows visual marking of line and load side of fuses.
## **Typical Applications**
- Class H, R and J fuse blocks up to 100A
- Class T fuse blocks up to 60A
- Class CC, G and Midget, 30A fuse blocks
## **Dimensions**
**==> picture [238 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
S S So SS SS<br>TEST PROBE TEST PROBE B<br>A C<br>= — L- 5<br>FUSE<br>LOAD SAMI -2 Buss LINE<br>**----- End of picture text -----**<br>
*For indicating cover, add suffix “I”, for non-indicating cover, add suffix “N”. Example: SAMI-7I = Indicating, SAMI-7N = Non-indicating.
**Available in non-indicating only. †SAMI-8A adapter available for small Fusetron[™] body design. SAMI-8I and SAMI-8N come standard with adapter (SAMI-8A). ††Not for use with KTS-R fuses.
**Data Sheet: 1204 (Trimming Guides: 12041, 12042, 12043, 12044, 12045, 12046, 12048, 12049)**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**288**
**Fuse Holders and Blocks**
## **Modular Knifeblade Fuse Blocks**
## **Class R, H(K), & J Applications up to 600 Amps**
## **Specifications**
## Ratings:
Volts: — 250V, 600V Amps: — 70-600A SCCR: — 200kA (Class R & J) 10kA (Class H & K)
## Agency Information:
Blocks: UL - Listed cULus E14853 – IZLT & IZLT7 CSA - Certified 47235 – 6225-01
Covers: UL - Listed UL E58836 – JDVS2 CSA - Certified 47235 – 6225-01
## Flammability Ratings:
Blocks: UL 94V0, self-extinguishing Covers: UL 94HB, self-extinguishing
## Operating & Storage Temperature Range:
Blocks -40ºC to 120ºC
- Covers non-indicating covers -40ºC to 120ºC indicating covers -20ºC to 90ºC
## Materials:
Base – Thermoplastic Box Lug – Tin-plated aluminum
## **Features and Benefits**
- Integral dovetails allow snapping together multiple poles at point-of-use for greater application flexibility
- Factory assembled two- and three-pole configurations available
- Up to four mounting holes per pole increase installation flexibility
- Standard phase barriers between poles for additional safety
- Design meets UL creep and clearance requirements for Industrial Control Circuits (UL 508 and UL 845)
- 200 to 600A blocks meet the higher UL creep and clearance requirements for Industrial Power Distribution Standards (UL 98, UL 69, UL 489, UL 891 and UL 869A)
- Optional IP20 finger-safe covers available on entire knifeblade fuse block product line:
- High-clarity see-through covers allow for inspecting wire terminations or thermography measurements without removing cover
- Probe holes included for easy, safer testing and troubleshooting
- Built-in lockout/tagout feature improves safety
- Standard fuse clip reinforcing springs enhance electrical contact
## **Typical Applications**
- Critical power, factory automation, renewable energy, HVAC, building/elevator controls, building entrance, process industries
## Wire:*
Cu/Al – 75ºC/90ºC (100 - 200A) Cu/Al – 75ºC only (400 - 600A)
*Higher temperature rated wire can be used with appropriate derating.
Scan this tag to get the latest product information for the Modular Knifeblade Fuse Blocks.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**289**
**Fuse Holders and Blocks**
## **Modular Knifeblade Fuse Blocks Part Number Table**
|CatalogNumber|CatalogNumber|Covers*|Covers*|Volts|Fuse Range<br>(amps)|Number<br>of Poles|Wire Range<br>(solid and stranded)***|Wire Range<br>(fine stranded Cu)|Torque<br> N•m (Lb-in)|Cooper Bussmann<br>Fuses|
|---|---|---|---|---|---|---|---|---|---|---|
|Class H(K)|Class R|w/o Indication|w/ Indication||||||||
|HM25100-1CR|RM25100-1CR|CVR-RH-25100|CVRI-RH-25100|250|70-<br>100|1|–<br>1/0-3 AWG; (2) Cu 4-6 AWG<br>4-6 AWG; (2) Cu 8 AWG<br>8 AWG; (2) Cu 10-14 AWG<br>Cu 10-14 AWG;Al 10-12 AWG|1-3 AWG<br>4-6 AWG<br>8 AWG<br>–<br>–|6.2 (55)<br>5.6 (50)<br>5.1 (45)<br>4.5 (40)<br>4.0(35)|Class H(K):<br>NON<br>Class R:<br>LPN-RK_SP<br>PN-RK_SPI**<br>FRN-R<br>KTN-R|
|HM25100-2CR|RM25100-2CR|||||2|||||
|HM25100-3CR|RM25100-3CR|||||3|||||
|HM25200-1CR|RM25200-1CR|CVR-RH-25200|CVRI-RH-25200||110-<br>200|1|250 MCM-1 AWG<br>2-6 AWG; (2) Cu 2-6 AWG|3/0-1 AWG<br>2-6 AWG|42 (375)<br>31 (275)||
|HM25200-2CR|RM25200-2CR|||||2|||||
|HM25200-3CR|RM25200-3CR||||||||||
|HM25400-1CR|RM25400-1CR|CVR-RH-25400|CVRI-RH-25400||225-<br>400|1|600kcmil<br>500kcmil-4 AWG<br>(2) Cu 3/0 - 4 AWG<br>(2)Al 3/0 - 4 AWG|N/A|57 (500)<br>51 (450)<br>57 (500)<br>34(300)||
|HM25400-2CR|RM25400-2CR|||||2|||||
|HM25400-3CR|RM25400-3CR|||||3|||||
|HM25600-1CR|RM25600-1CR|CVR-RH-25600|CVRI-RH-25600||450-<br>600|1|(2) 500kcmil-4 AWG|N/A|51 (450)||
|HM25600-2CR|RM25600-2CR|||||2|||||
|HM25600-3CR|RM25600-3CR|||||3|||||
|HM60100-1CR|RM60100-1CR|CVR-RH-60100 <br> CVR-RH-60200|CVRI-RH-60100<br> CVRI-RH-60200|600|70-<br>100|1|–<br>1/0-3 AWG; (2) Cu 4-6 AWG<br>4-6 AWG; (2) Cu 8 AWG<br>8 AWG; (2) Cu 10-14 AWG<br>Cu 10-14 AWG;Al 10-12 AWG|1-3 AWG<br>4-6 AWG<br>8 AWG<br>–<br>–|6.2 (55)<br>5.6 (50)<br>5.1 (45)<br>4.5 (40)<br>4.0(35)|Class H(K):<br>NOS<br>Class R:<br>LPS-RK_SP<br>PS-RK_SPI**<br>FRS-R<br>KTS-R<br>KWS-R<br>PVS-R|
|HM60100-2CR|RM60100-2CR|||||2|||||
|HM60100-3CR|RM60100-3CR|||||3|||||
|HM60200-1CR|RM60200-1CR||||110-<br>200|1|250 MCM-1 AWG<br>2-6 AWG; (2) Cu 2-6 AWG|3/0-1 AWG<br>2-6 AWG|42 (375)<br>31 (275)||
|HM60200-2CR|RM60200-2CR|||||2|||||
|HM60200-3CR|RM60200-3CR||||||||||
|HM60400-1CR|RM60400-1CR|CVR-RH-60400|CVRI-RH-60400||225-<br>400|1|600kcmil<br>500kcmil-4 AWG<br>(2) Cu 3/0 - 4 AWG<br>(2)Al 3/0 - 4 AWG|N/A|57 (500)<br>51 (450)<br>57 (500)<br>34(300)||
|HM60400-2CR|RM60400-2CR|||||2|||||
|HM60400-3CR|RM60400-3CR|||||3|||||
|HM60600-1CR|RM60600-1CR|CVR-RH-60600|CVRI-RH-60600||450-<br>600|1|(2) 500kcmil-4 AWG|N/A|51 (450)||
|HM60600-2CR|RM60600-2CR|||||2|||||
|HM60600-3CR|RM60600-3CR|||||3|||||
*Covers sold serarately. Blown fuse indication requires 90 volts minimum and closed circuit to operate.
**With easyID™ blown fuse indication. ***Ratings for copper and aluminum wire except where otherwise noted.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**290**
**Fuse Holders and Blocks** Bt
## **250V Class R & H(K) Dimensional Specifications**
## **Dimensions - mm (in)**
70- 100A
110- 200A
**==> picture [54 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
225- 400A<br>**----- End of picture text -----**<br>
## 450- 600A
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**291**
**Fuse Holders and Blocks**
## **600V Class R & H(K) Dimensional Specifications**
## **Dimensions - mm (in)**
## 70- 100A
## 110- 200A
225- 400A
450- 600A
For engineering drawings, go to www.cooperbussmann.com/KnifebladeFuseBlocks
**292**
**Fuse Holders and Blocks** na
## **Class J Dimensional Specifications**
## **Dimensions - mm (in)**
## 70- 100A
## 110- 200A
## 225- 400A
## 450- 600A
For engineering drawings, go to www.cooperbussmann.com/KnifebladeFuseBlocks
**293**
**Fuse Holders and Blocks**
## **Class H(K) and R Fuse Blocks – 250V**
## **H250 & R250 Series**
## **Specifications**
## **Descriptions:**
- **H250 Series:** 1-, 2- and 3-pole fuse blocks for use with Class H fuses.
- **R250 Series:** 1-, 2- and 3-pole fuse blocks for use with Class
- R fuses (Bussmann LPNRK and FRN-R and KTN-R fuses).
- **Dimensions:** See Dimensions illustrations.
## **Ratings:**
- Volts: — 250Vac/dc (H250 & R250 Series)
Amps: —[1] ⁄10-100A
- SCCR: — H250 Series; 10kA RMS Sym.
- R250 Series; 200kA RMS Sym.
**Agency Information:** CE, UL Listed UL 4248, Guide IZLT, File E14853; CSA Certified, Class 6225-01, File 47235. **Flammability Rating:** UL 94V0.
## **Features and Benefits**
- H250 fuse blocks provide one, two and three pole housing for Class H, K and R fuses at 250Vac.
- H250 fuse blocks are listed with a Short-Circuit Current Rating of 10kA RMS Sym.
- R250 fuse blocks provide 1-, 2- and 3-pole housing for Class R fuses at 250Vac.
- R250 fuse blocks are listed with a Short-Circuit Current Rating of 200kA RMS Sym.
## **Typical Applications**
- 250Vac/dc or less Control Systems
- 250Vac/dc or less Industrial Control
- 250Vac/dc or less Industrial Control Circuits
## **Recommended DIN-Rail adapters for the[1] ⁄10-30A series**
- see page 509.
**Class H Fuseblocks (250V) Catalog Data (for NON and REN Fuses)**
|**Amps**|**Poles**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Figure**<br>**Number**|**Wire**<br>**Range**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||**Screw**|||||**Box Lug w/**||||||
|||**Catalog**<br>**Number**|**—**|**Clip with**<br>**Reinforced**<br>**Spring**|**Pressure**<br>**Plate**|**Pressure Plate**<br>**& Clip with**<br>**Reinforced Spring**|**—**|**Clip with**<br>**Reinforced**<br>**Spring**|**Copper**<br>**Only**|**0.25˝**<br>**Quick**<br>**Connect**|||
|1⁄10<br>to<br>30|1|H25030-1|S SR|S SR|P PR|P PR|C|CR|—|Q|1|C, CR #2-14 Cu, #2-12 Al<br>P, PR #10-18 Cu Only<br>Q N/A<br>S,SR #10-18 Cu Only|
||2|H25030-2|S SR|S SR|P PR|P PR|C CR|C CR|—|—|2||
||3|H25030-3|S SR|S SR|P PR|P PR|C CR|C CR|—|—|3||
|31<br>to<br>60|1|H25060-1|—|—|—|—|C|CR|CO|—|4|C, CR #2-14 Cu, #2-8 Al<br>CO #2-14 Cu Only|
||2|H25060-2|— —|— —|— —|— —|C|CR|CO|—|5||
||3|H25060-3|— —|— —|— —|— —|C|CR|CO|—|6||
|61<br>to<br>100|1|H25100-1|— SR|— SR|— —|— —|— CR|— CR|—|—|7|CR #1/0-8 Cu/Al<br>SR #8W/ Ring Terminal|
||2|H25100-2|— SR|— SR|— —|— —|—|CR|—|—|8||
||3|H25100-3|— SR|— SR|— —|— —|— CR|— CR|—|—|9||
~~OEE~~ **Data Sheet: H250 Series, 1112; R250 Series, 1110 294** For engineering drawings, go to www.cooperbussmann.com/KnifebladeFuseBlocks
**Fuse Holders and Blocks**
## **Class H(K) and R Fuse Blocks – 250V**
**Class R Fuseblocks (250V) Catalog Data (for LPN-RK, FRN-R and KTN-R Fuses)**
|**Poles**<br>**Amps**|**Poles**<br>**Amps**|<br>**Scre**<br>**Catalog**<br>**Number**<br>**—**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|
|---|---|---|---|---|
||||**w w/**<br>**Box Lug w/**<br>**0.25”**<br>**Pres.**<br>**Clip**<br>**Quick**<br>**Plate**<br>**—**<br>**Cu Only**<br>**Conne**||
||||**Pres.**<br>**Plate**<br>**—**||
|1⁄10<br>to<br>30|1<br>2<br>3|R25030-1<br>SR|PR<br>CR|COR<br>QR*|
|||R25030-2<br>SR|PR<br>CR|COR<br>—|
|||R25030-3<br>SR|PR<br>CR|COR<br>—|
|31<br>to<br>60|1<br>2<br>3|R25060-1<br>—|—<br>CR|—<br>—|
|||R25060-2<br>—|—<br>CR|—<br>—|
|||R25060-3<br>—|—<br>CR|—<br>—|
|61<br>to<br>100|1<br>2<br>3|R25100-1<br>—|—<br>CR|—<br>—|
|||R25100-2<br>—|—<br>CR|—<br>—|
|||R25100-3<br>—|—<br>CR|—<br>—|
## **Dimensions – in 250V[1] ⁄10 to 30A**
**==> picture [359 x 445] intentionally omitted <==**
**----- Start of picture text -----**<br>
3"<br>2.05"<br>2.5"<br>1.41"0.22" 0.17 " 1.09" 0.75" 0.41" 0.95"1.25" 0.25" 2 SPACES AT 0.95" - 1.91"<br>1.27"<br>3.03"<br>0.5"<br>1.52"<br>0.22" DIAMETER 0.55" 0.55"<br>FIGURE 1. FIGURE 2. FIGURE 3.<br>250V, 31A to 60A<br>2.81 4.125<br>1.73 1.5 0.5 1 .31 0.5 1.3 1 1 .3 1<br>0.27 0.5 0.5 0.5<br>0.22 x 0.41 0.22 x 0.41 0.22 x 0.41<br>4.25 1.25G<br>1.5<br>FIGURE 4. FIGURE 5. FIGURE 6.<br>250V, 61A to 100A<br>3.38" 4.94"<br>2.06" 1.81" 0.59" 1.56" 0.59" 1.56" 1.56"<br>0.25" 0.62" 0.62" 0.62"<br>0.28" DIA. x<br>0.5" C'BORE<br>7.36"<br>3.125"<br>2.38"<br>2.125"<br>FIGURE 7. FIGURE 8. FIGURE 9.<br>**----- End of picture text -----**<br>
**==> picture [205 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data Sheet: H250 Series, 1112; R250 Series, 1110<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**295**
**Fuse Holders and Blocks**
## **Class H(K) and R Fuse Blocks – 600V**
## **H600 & R600 Series**
## **Specifications Descriptions:**
**H600 Series:** fuse blocks for use with 1-, 2- and 3-pole Class H fuses.
- **R600 Series:** fuse blocks for use with 1-, 2- and 3-pole
- Class R fuses (Bussmann LPS-RK, FRS-R, PVS-R and KTS-R fuses).
- **Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts: — 600Vac/dc (H600 & R600 Series)
Amps: —[1] ⁄10-100A
SCCR: — H600 Series; 10kA RMS Sym.
- R600 Series; 200kA RMS Sym.
**Agency Information:** CE, UL Listed UL 4248, Guide IZLT, File E14853; CSA Certified, Class 6225-01, File 47235. **Flammability Rating:** UL 94V0.
> **H60030-3C** ~~&~~ **H60030-2PR**
> **Features and Benefits** & • H600 fuse blocks provide one-, two- and three-pole housing for Class H, K and R fuses at 600Vac.
- H600 fuse blocks are listed with a Short-Circuit Current Rating of 10kA RMS Sym.
- R600 fuse blocks provide one-, two- and three-pole housing for Class R fuses at 600Vac.
- R600 fuse blocks are listed with a Short-Circuit Current Rating of 200kA RMS Sym.
## **Typical Applications**
- 600Vac/dc or less Control Systems
- 600Vac/dc or less Industrial Control
- 600Vac/dc or less Individual Control Circuits
**Class H Fuseblocks (600V) Catalog Data (for NOS and RES Fuses)**
|**Amps**|**Poles**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Terminal Type (Suffix No.)**|**Figure**<br>**Number**|**Wire**<br>**Range**|
|---|---|---|---|---|---|---|---|---|---|---|
|||**Screw**|||||**Box Lug w/**||||
|||**Catalog**<br>**Number**|**—**|**Clip with**<br>**Reinforced**<br>**Spring**|**Pressure**<br>**Plate**|**Pressure Plate**<br>**& Clip with**<br>**Reinforced Spring**|**—**|**Clip with**<br>**Reinforced**<br>**Spring**|||
|1⁄10<br>to<br>30|1|H60030-1|S SR|S SR|P PR|P PR|C|CR|1|C, CR #2-14 Cu, #2-12 Al<br>P, PR, S, SR #10-18 Cu Only|
||2|H60030-2|S SR|S SR|P PR|P PR|C CR|C CR|2||
||3|H60030-3|S SR|S SR|P PR|P PR|C CR|C CR|3||
|31<br>to<br>60|1|H60060-1|—|—|—|—|C|CR|4|C, CR #2-14 Cu, #2-8 Al|
||2|H60060-2|— —|— —|— —|— —|C|CR|5||
||3|H60060-3|— —|— —|— —|— —|C|CR|6||
|61<br>to<br>100|1|H60100-1|— —|— —|— —|— —|— CR|— CR|7|CR #1/0-8 Cu/Al|
||2|H60100-2|— —|— —|— —|— —|—|CR|8||
||3|H60100-3|— —|— —|— —|— —|— CR|— CR|9||
**Data Sheet: H600 Series, 1113; R600 Series, 1111**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**296**
**Fuse Holders and Blocks**
## **Class H(K) and R Fuse Blocks – 600V**
## **Class R Fuseblocks (600V) Catalog Data (for LPS-RK, FRS-R, PVS-R and KTS-R Fuses)**
|**Amps**|**Poles**|**Te**<br>**Sc**<br>**Catalog**<br>**Number**<br>**—**|**rminal Type (Suffix No.)**|**rminal Type (Suffix No.)**|**rminal Type (Suffix No.)**|
|---|---|---|---|---|---|
||||**rew w/**|**Box Lug w/**<br>**Clip**<br><br>**—**<br>**Cu Only**<br>||
||||**Pres.**<br>**Plate**|**—**||
|1⁄10<br>to<br>30|1<br>2<br>3|R60030-1<br>SR|PR|CR|—|
|||R60030-2<br>SR|PR|CR|COR|
|||R60030-3<br>SR|PR|CR|COR|
|31<br>to<br>60|1<br>2<br>3|R60060-1<br>—|—|CR|—|
|||R60060-2<br>—|—|CR|—|
|||R60060-3<br>—|—|CR|—|
|61<br>to<br>100|1<br>2<br>3|R60100-1<br>—|—|CR|—|
|||R60100-2<br>—|—|CR|—|
|||R60100-3<br>—|—|CR|—|
## **Dimensionals – in**
## **600V,[1] ⁄10 to 30A**
**==> picture [369 x 443] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.90 4.25<br>1.73 1.54 0.25 1.56 0.25 1.56 1.56<br>0.26 0.62 0.62 0.62<br>0.28 x 0.5 0.28 x 0.5 0.28 x 0.5<br>6.25 3.13<br>1.56<br>FIGURE 1. FIGURE 2. FIGURE 3.<br>600V, 31 to 60A 3.38" 4.94"<br>2.06" 1.81" 0.59" 1.56" 0.59" 1.56" 1.56"<br>0.25" 0.62" 0.62" 0.62"<br>0.28" DIA. x<br>0.5" C'BORE<br>7.36"<br>3.125"<br>2.38"<br>2.125"<br>FIGURE 4. FIGURE 5. FIGURE 6.<br>600V, 61 to 100A<br>2.22<br>2 .38 0.88 0.67 4.03 1 .8 1 0.67 1 .8 1 5.84 1 .8 1<br>0.34 0.88 0.88<br>0.28 x 0.5<br>0.28 x 0.5 0.28 x 0.5<br>9.5<br>4.25<br>2.63<br>FIGURE 7. FIGURE 8. FIGURE 9.<br>**----- End of picture text -----**<br>
## **Data Sheet: H600 Series, 1113; R600 Series, 1111**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**297**
**Fuse Holders and Blocks**
## **Class J Fuse Blocks**
## **J600 Series**
## **Specifications**
**Description:** 1-, 2- or 3-pole fuse blocks for use with Class J fuses (Bussmann LPJ, DFJ and JKS).
**Dimensions:** See Dimensions illustrations.
**Construction:** Thermoplastic.
**Poles:** 1 to 3
## **Ratings:**
Volts: — 600Vac/dc Amps: —[1] ⁄2-100A
SCCR: — 200kA RMS Sym.
**Agency Information:** CE, UL Listed, UL 4248, Guide IZLT, File E14853, CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235.
**Flammability Rating:** UL 94V0.
**Mounting:** Accepts DIN-Rail adapter DRA-1. See page 507.
## **Features and Benefits**
- J600 fuse blocks provide one-, two- and three-pole housing for Class J fuses at 600Vac.
- J600 fuse blocks are listed with a Short-Circuit Current Rating of 200kA RMS Sym.
## **Typical Applications**
- 600Vac/dc or less Control Systems
- 600Vac/dc or less Industrial Control
## **Catalog Numbers**
- 600Vac/dc or less Individual Control Circuits
|**Screw†**|**Pressure**<br>**Plate†**|**Box**<br>**Lug**|**og**<br>**Box Lug w/**<br>**Retaining Clip**|**p**<br>**Amps**|**Poles**|**Fig.**<br>**No.**|**Wire**<br>**Range**|
|---|---|---|---|---|---|---|---|
|J60030-1S*<br>~~a~~|J60030-1P<br>~~a~~|J60030-1C|J60030-1CR††||1<br>~~ee~~|1<br>~~ee~~|C, CR #2-14 Cu, #2-8 Al<br>COR #2-14 Cu Only<br>P, PR, S, SR #10-14 Cu Only|
|J60030-2S*<br>~~a~~<br>~~——~~<br>~~a~~|J60030-2P<br>~~a~~<br>~~——~~<br>~~a~~|J60030-2C<br>~~——~~|J60030-2CR††|1⁄2-30<br>1⁄2-30|2<br>~~ee~~<br>~~|~~|2<br>~~ee~~<br>||
|J60030-3S*<br>~~——~~<br>~~a~~<br>~~a~~|J60030-3P<br>~~——~~<br>~~a~~<br>~~a~~|J60030-3C<br>~~——~~|J60030-3CR††||3<br>~~||~~<br>~~|~~|3<br>~~|~~<br>||
|—<br>~~a~~<br>~~a~~<br>~~1~~|—<br>~~a~~<br>~~a~~<br>~~1~~|J60060-1C<br>~~1~~|J60060-1CR††<br>~~1~~|~~1OE~~|1<br>~~||~~<br>~~||~~<br>~~OE~~|1<br>~~|~~<br>~~|~~<br>~~OE~~|14 Cu Only<br>C, CR, #2-14 Cu/Al<br>COR #4-14 Cu Only|
|—<br>~~a~~<br>~~1~~<br>~~a~~|—<br>~~a~~<br>~~1~~<br>~~a~~|J60060-2C<br>~~1~~|J60060-2CR††<br>~~1~~|31-60<br>31-60<br>~~1OE~~|2<br>~~||~~<br>~~OE~~<br>~~|~~|2<br>~~|~~<br>~~OE~~<br>||
|—<br>~~1~~<br>~~a~~<br>~~-——+—}+——j_~~<br>~~Po~~|—<br>~~1~~<br>~~a~~<br>~~-——+—}+——j_~~<br>~~Po~~|J60060-3C<br>~~1~~<br>~~-——+—}+——j_~~<br>~~Po~~|J60060-3CR††<br>~~1~~<br>~~-——+—}+——j_~~<br>~~Po~~|~~1OE~~<br>~~-——+—}+——j_~~<br>~~Po~~|3<br>~~OE~~<br>~~||~~<br>~~}#+~~|3<br>~~OE~~<br>~~|~~<br>~~+~~||
|—<br>~~1~~<br>~~a~~<br>~~-——+—}+——j_~~<br>~~Po~~|—<br>~~1~~<br>~~a~~<br>~~-——+—}+——j_~~<br>~~Po~~|—<br>~~1~~<br>~~-——+—}+——j_~~<br>~~Po~~|J60100-1CR<br>~~1~~<br>~~-——+—}+——j_~~<br>~~Po~~|61-100<br>~~61-100~~<br>~~1 OE~~<br>~~-——+—}+——j_~~<br>~~Po~~|1<br>~~OE~~<br>~~||~~<br>~~}#+~~|4<br>~~OE~~<br>~~|~~<br>~~+~~|COR 1/0-8 Cu Only<br>CR, CRQ 1/0-8 Cu/Al|
|—<br>~~-——+—}+——j_~~<br>~~Po~~|—<br>~~-——+—}+——j_~~<br>~~Po~~|—<br>~~-——+—}+——j_~~<br>~~Po~~|J60100-3CR††<br>~~-——+—}+——j_~~<br>~~Po~~|~~61-100~~<br>~~-——+—}+——j_~~<br>~~Po~~|3<br>~~|~~<br>~~}#+~~<br>~~a~~|5<br>~~|~~<br>~~+~~<br>~~a~~||
††Copper only connections available by changing “CR” suffix to “COR”.
*No UL, No CSA Certification
## **Dimensions - in (±0.015)**
**==> picture [507 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
1⁄2 - 60A 61-100A<br>2.415" 1.702 3.202 4.702<br>.750 2.250 .750 2.250 .2.28" 30" .94 " 1.583" 5"<br>adel heed eco le eee<br>.22"<br>Al lalal (alah) 6.28" (= fee Dia. ae<br>Hel! enter) L e be n CL d e r CL 4.005 Prt .5"C'Bore<br>PL HOE WIC eOO,-) [ Key 3.14" eg<br>Hay Pa t an) Heater | r<br>— 1 .500 bk 1.75" sk 1.5" 4<br>FIGURE 1. FIGURE 2. FIGURE 3. FIGURE 4. FIGURE 5.<br>**----- End of picture text -----**<br>
**Data Sheet: 1114**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**298**
**Fuse Holders and Blocks**
## **Class J Fuse Blocks**
## **JP Series**
## **Specifications**
**Description:** Pyramid style 3-pole fuse block for use with Class J fuses (Bussmann LPJ, DFJ, JKS).
**Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts: — 600Vac/dc
Amps: — 0-30A
SCCR: — 200kA RMS Sym.
**Agency Information:** CE, UL Listed, UL 4248, Guide IZLT, File E14853, CSA Certified, C22.2 No. 39, Class 4225-04, File 47235.
## **Flammability Rating:** UL 94V0.
**Mounting:** Panel or 35mm DIN-Rail mount.
To order DIN-Rail: Part# NDNA 100 (1 meter) or NDNA 200 (2 meter).
## **Catalog Numbers**
||||**Mounting**||||
|---|---|---|---|---|---|---|
|**Catalog**<br>**Numbers**<br>**Panel**|**Panel**|**With**<br>**DIN**<br>**Rail**<br>**Adapter***|**Screws**<br>**with**<br>**Pressure**<br>**ter* Plate**|**Box**|||
|||||**Aluminum**|**Copper**<br>**Only**|**Wire Range**|
|JP60030-3PR<br>X|||X|||#10-14 Cu Only|
|JP60030-3CR<br>X||||X||14 Cu Only<br>#2-14 Cu/Al|
|JP60030-3COR<br>X|||||X|#2-14 Cu Only|
|JP60030-3PRA||X|X|||14 Cu Only<br>#10-14 Cu Only|
|JP60030-3CRA||X||X||14 Cu Only<br>#2-14 Cu/Al|
|JP60030-3CORA||X|||X|#2-14 Cu Only|
*Adapter only for DIN-Rail - Cat No. JPA-3.
## **Dimensions - in ± 0.015” (± 0.40mm)**
**==> picture [235 x 212] intentionally omitted <==**
**----- Start of picture text -----**<br>
DIN-RAIL MOUNTING SCREW 8" (203.2mm) APART<br>END STOPS - PREVENT BLOCK MOVEMENT WHEN CHANGING FUSES<br>4.00" MAX.<br>(101.6mm)<br>3.75" (0.02)<br>(95.3mm (0.50)<br>1.88"<br>(47.6mm)<br>1.19"<br>(30.2mm)<br>2.38"<br>(60.4mm)<br>3.29"<br>aad (83.6mm)<br>**----- End of picture text -----**<br>
**==> picture [205 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.78"<br>3.06" (70.6mm)<br>(77.8mm)<br>3.13"<br>(79.5mm)<br>ADAPTOR<br>FOR 35mm<br>SYMMETRICAL<br>DIN-RAIL<br>MOUNTING<br>**----- End of picture text -----**<br>
**Data Sheet:1108**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**299**
**Fuse Holders and Blocks**
## **Class T Fuse Blocks – 300V**
## **T300**
## **Specifications**
**Description:** T300 (300V) fuse blocks for use with Class T fuses (Bussmann JJN).
**Dimensions:** See Dimensions illustrations.
**Poles:** 1 to 4
**Ratings:**
Volts: — 300Vac/dc Amps: —[1] ⁄2 - 600A
**==> picture [44 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
T30100-1CR<br>**----- End of picture text -----**<br>
**==> picture [44 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
T30030-2CR<br>**----- End of picture text -----**<br>
SCCR:— 200kA RMS Sym.
**Agency Information:** CE, UL Listed UL 4248, Guide IZLT, File E14853, CSA Certified, Class 6225-01, File 47235. **Flammability Rating:** UL 94V0.
## **Features and Benefits**
- Provide 1-, 2- and 3-pole housing for 300Vac Class T fuses.
**==> picture [39 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
T30600-1C<br>**----- End of picture text -----**<br>
- Short-Circuit Current Rating of 200kA RMS Sym.
- Class T fuse blocks have a small foot print, providing substantial space savings in equipment
## **Typical Applications**
- 300Vac/dc or less Control Systems
- 300Vac/dc or less Individual Control Circuits
**Catalog Numbers Catalog Numbers Fig. Screw Box Lug Amps Poles No. Wire Range** T30030-2SR T30030-2CR 1/2-30 2 1 T30030-3SR T30030-3CR 1⁄2-30 3 SR #10-18 Cu CR #6-14 Cu/Al T30030-4SR T30030-4CR 4 ~~1~~ T30060-2SR T30060-2CR 31-60 2 1 CR #2-14 Cu/Al T30060-3SR T30060-3CR 31-60 3 T30060-4SR T30060-4CR 4 SR #10-18 Cu Only — T30100-1CR 61-100 1 2 — T30100-2CR 61-100 2 2 1/0-8 Cu/Al — T30100-3CR 3 — T30200-1C 101-200 1 3 ~~101-200~~ 250kcmil-6 Cu/Al — T30200-3C 3 4 — T30400-1C 201-400 1 5 600kcmil-2/0 Cu/Al ~~a~~ — T30600-1C 401-600 1 6 (2) 600kcmil-4/0 Cu/Al **Dimensions - in Figure 1.[1] ⁄2-60A** 1.63" ~~1.63"~~ **A** 0.72" 1.20" **B** 0.72" ~~BS~~ 0.16" 0.69" ~~bea~~ **X Z** ~~Fe~~ 0.16" **Catalog Dimensions - in** |_ ~~|~~ wan © A PEN | ~~SRD,~~ r) L ~~o~~ **Number A B C** T30030-2 2.41 — 1.03 T30060-2 2.41 — 1.03 T30030-3 3.44 1.03 2.06 0.91" 2.75" 2.5" 0.91" T30060-3 3.44 1.03 2.06 T30030-4 4.47 2.06 3.09 T30060-4 4.47 2.06 3.09 **T30030-S X Z T30060-C SECTION X-X** ~~"~~ I ~~L~~ 0.44" **Full** | **SECTION Z-Z** ~~lL~~ 0.20" **Radius C**
**Data Sheet: 1115**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**300**
**Fuse Holders and Blocks**
## **Class T Fuse Blocks – 300V**
## **Figure 2. 61 to 100A**
## **Figure 3. 101 to 200A**
**==> picture [490 x 181] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.69" (1 POLE) 6" 0.05"<br>3.09" (2 POLE)<br>2.06" 4.5" (3 POLE) 3"<br>0.84 " 1.41 " (2 POLE) 1.125"<br>2.81" (3 POLE)<br>1.25" 2.25"<br>X Z<br>1.69" 0.28" DIAMETER<br>0.22" DIA. 0.63" C'BORE 0.5" DEEP<br>0.52" C'BORE<br>0.55" DEEP<br>2.25"<br>4.78"<br>REF.<br>3.06"<br>2.56"<br>2.39" 1.94"<br>0.81"<br>X Z<br>0.38"<br>0.75"<br>**----- End of picture text -----**<br>
**Figure 5. 201 to 400A**
**Figure 4. 200A**
**==> picture [524 x 228] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.87" 6"<br>1.695" 3"<br>.996"<br>1.25" 2.25"<br>1.125"<br>0.63"<br>0.28" DIAMETER<br>A 2.75" 0.63" C'BORE 0.5" DEEP<br>A<br>1.84"<br>0.282" DIAMETER THRU HOLE<br>0.625" C'BORE 0.438" DEEP<br>3.06"<br>2.38"<br>2.375" 0.81"<br>0.625"<br> 4.46"<br>**----- End of picture text -----**<br>
**Figure 6. 401 to 600A**
**==> picture [506 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.75" 2.03"<br>2.88"<br>1.5" 3.44"<br>2" 3" 3"<br>0.75"<br>0.33" DIAMETER<br>0.75" C'BORE 0.5" DEEP<br>**----- End of picture text -----**<br>
**Data Sheet: 1115**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**301**
**Fuse Holders and Blocks**
## **Class T Fuse Blocks – 600V**
## **T600**
## **Specifications**
**Description:** T600 (600V) fuse blocks for use with Class T fuses (Bussmann JJS).
**Dimensions:** See Dimensions illustrations.
**Poles:** 1 to 3
## **Ratings:**
Volts: — 600Vac/dc Amps: —[1] ⁄2 - 600A SCCR:— 200kA RMS Sym.
**Agency Information:** CE, UL Listed UL 4248, Guide IZLT, File E14853, CSA Certified, Class 6225-01, File 47235. **Flammability Rating:** UL 94V0.
## **Features and Benefits**
- Provide 1-, 2- and 3-pole housing for 600Vac Class T fuses.
- Short-Circuit Current Rating of 200kA RMS Sym.
- Class T fuse blocks have a small foot print, providing substantial space savings in equipment
## **Typical Applications**
- 600Vac/dc or less Control Systems
- 600Vac/dc or less Individual Control Circuits
**==> picture [182 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
T60600-1C<br>T30030-2CR<br>**----- End of picture text -----**<br>
## **Catalog Numbers**
|**Screw**|**Box Lug**<br>**Amps**|**Amps**|**Fig.**<br>**Poles No.**|**Poles No.**|**Wire Range**|
|---|---|---|---|---|---|
|T60030-1SR|T60030-1CR||1|1<br>1|SR #10-18 Cu<br>CR #2-14 Cu/Al|
|T60030-2SR|T60030-2CR<br>1/2|1/2**-30**<br>1⁄2|2|||
|T60030-3SR|T60030-3CR||3|||
|T60060-1SR|T60060-1CR||1|2<br>2|CR #2-14 Cu/Al<br>SR #10-18 Cu Only|
|T60060-2SR|T60060-2CR<br>31|31-60|2|||
|T60060-3SR|T60060-3CR<br>31-60|31-60|3|||
|—|T60100-1C||1|3<br>3|2/0-14 Cu/Al|
|—|T60100-2C<br>61<br>~~61-100~~|61-100<br>~~61-100~~|2|||
|—|T60100-3C<br>~~61-100~~|~~61-100~~|3|||
|—|T60200-1C<br>101<br>~~101-200~~|101-200<br>~~101-200~~|200<br>1|4<br>~~4~~|250kcmil-6 Cu/Al|
|—|1B0089*<br>~~101-200~~|~~101-200~~|3|||
|—|T60400-1C<br>201|201-400|400<br>1|5|600kcmil-2/0 Cu/Al|
|—|T60600-1C<br>401|401-600|600<br>1|6|(2) 600kcmil-4/0 Cu/Al|
* UL Listed, Guide IZLT, File E14853, CSA Certified Class 6225-01, File 21455M18
## **Dimensions - in**
**Figure 1.[1] ⁄2 to 30A**
**==> picture [459 x 261] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.44" 1.44" 2.59" 3.75"<br>0.5" 0.55" 0.33" 0.55" 1.16" 0.33" 0.55" 2.31" 0.33"<br>0.22" DIAMETER<br>Rs Tan TA TAA. A<br>0.33" 0.5" C'BORE<br>3.19" 1.563"<br>1.42"<br>a? U td Uistit | UistUist ist<br>Figure 2. 31 to 60A<br>1.75" 1.81" 3.34" 4.86"<br>0.5" 0.59" 0.63" 0.59" 1.53" 0.63" 0.59" 3.06" 0.63"<br>0.22" DIAMETER<br>ja a n Tan ce ASSESS! 1<br>0.5" C'BORE<br>2.94" 1.63"<br>1.47"<br>Data Sheet: 1116<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**302**
**Fuse Holders and Blocks**
## **Class T Fuse Blocks – 600V**
## **Figure 3. 61 to 100A**
**==> picture [291 x 216] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.69" (1 POLE)<br>3.09" (2 POLE)<br>4.5" (3 POLE)<br>0.84 " 1.41 " (2 POLE)<br>2.81" (3 POLE)<br>X Z 0.78"<br>0.22" DIA.<br>0.52" C'BORE<br>0.55" DEEP<br>2.34"<br>REF.<br>2.39"<br>X Z<br>SECTION Z-Z<br>0.38"<br>0.75"<br>**----- End of picture text -----**<br>
## **Figure 4. 101 to 200A**
**Figure 5. 201 to 400A**
**==> picture [523 x 196] intentionally omitted <==**
**----- Start of picture text -----**<br>
6" 0.05" 6"<br>3"<br>3"<br>1.125"<br>1.25" 2.25"<br>1.25" 2.25"<br>1.125"<br>2.5" 0.28" DIAMETER 0.63"<br>0.63" C'BORE 0.5" DEEP<br>0.28" DIAMETER<br>0.63" C'BORE 0.5" DEEP<br>2.72"<br>3.06"<br>2.56"<br>1.94"<br>0.81"<br>3.06"<br>2.38"<br>0.81"<br>**----- End of picture text -----**<br>
## **Figure 6. 401 to 600A**
**==> picture [470 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
6.75" 2.95"<br>3.38"<br>1.5" 3.44"<br>2" 3" 3"<br>0.75"<br>0.33" DIAMETER<br>0.75" C'BORE 0.5" DEEP<br>**----- End of picture text -----**<br>
**Data Sheet: 1116**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**303**
**Fuse Holders and Blocks**
## **Add-a-pole Fuse Blocks**
**BCA Series - Class CC fuses BMA Series -[13] ⁄32" X 1[1] ⁄2" fuses**
## **Dimensions in ± 0.015" (0.38mm)**
Adder Block **Specifications** 5 **Description:** 1-, 2 and 3-pole fuse blocks for use with Class CC fuses (BCA Series use Bussmann he LP-CC, KTK-R, and FNQ-R), or with standard[13] ⁄32" x 1[1] ⁄2" fuses (BMA Series use Bussmann KTK, FNQ, PVN, FNM, 1-Pole BAF, PV and AGU) Both Series use an Lc; "adder block" to form multi-pole segmented blocks to achieve the desired number of poles. **Dimensions:** See Dimensions illustration. 2-Pole
**Poles:** 1 to 3.
**Wire Range:** #10-#18 Cu only.
**Terminals:** Screw/quick connect* or pressure plate/quick connect*.
## **Ratings:**
Volts: — 600Vac/dc 3-Pole Amps: —[1] ⁄10-30A SCCR: — BCA Series: LA] 200kA RMS Sym. a \ a BMA Series: aS 4 By 10kA RMS Sym. r a = Fe
## **Agency Information:**
**BCA Series:** CE, UL Listed, UL 4248, Guide IZLT, File E14853.
CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235. **BMA Series:** CE, UL Recognized, UL 4248, Guide IZLT2, File E14853. CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235.
## **Flammability Rating:** UL 94V0
*Quick connect rated for 20A maximum.
## **Catalog Numbers**
## **BCA Series**
|**BCA Series**|||
|---|---|---|
|**Catalog Numbers**|**Poles**|**Terminal Type**|
|BCA603ASQ|Adder Block|Screw w/ quick connect|
|BCA6031SQ|1|Screw w/ quick connect|
|BCA6032SQ|2|Screw w/ quick connect|
|BCA6033SQ|3|Screw w/ quick connect|
|BCA603APQ|Adder Block|Pressure plate w/ quick connect|
|BCA6031PQ|1|Pressure plate w/ quick connect|
|BCA6032PQ|2|Pressure plate w/ quick connect|
|BCA6033PQ|3|Pressure plate w/ quick connect|
## **BMA Series**
|**BMA Series**|||
|---|---|---|
|**Catalog Numbers**|**Poles**|**Terminal Type**|
|BMA603ASQ|Adder Block|Screw w/ quick connect|
|BMA6031SQ|1|Screw w/ quick connect|
|BMA6032SQ|2|Screw w/ quick connect|
|BMA6033SQ|3|Screw w/ quick connect|
|BMA603APQ|Adder Block|Pressure plate w/ quick connect|
|BMA6031PQ|1|Pressure plate w/ quick connect|
|BMA6032PQ|2|Pressure plate w/ quick connect|
|BMA6033PQ|3|Pressure plate w/ quick connect|
**Data Sheets: BCA Series 1154, BMA Series 1155**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**304**
**Fuse Holders and Blocks**
## **Class CC, Type M and Class G Fuse Blocks**
## **BC Series**
## **BM Series Type M**
## **BG & G Series**
## **Specifications**
**Description:** Class CC fuse blocks for use with Class CC fuses ( Bussmann LP-CC, KTK-R, and FNQ-R).
**Dimensions:** See Data Sheet 1105 **Poles:** 1 to 3
## **Ratings:**
Volts: — 600V Amps: —[1] ⁄10-30A
SCCR:— 200kA RMS Sym.
**Agency Information:** CE, UL Listed (Guide IZLT, File E14853), CSA (Class 6225-01, File 47235) **Flammability Rating:** UL 94V0
**DIN-Rail Adapters:** See page 413 for DRA-1 & DRA-2
## **Catalog Numbers**
|**Data Sheet: 1105**<br>**Screw**<br>BC6031S<br>BC6032S<br>BC6033S|**Data Sheet: 1105**<br>**Terminal T**<br>**Screw**<br>**with**<br>**Quick**<br>**Pressure**<br>**Connect***<br>**Plate**<br>BC6031SQ<br>BC6031P<br>BC6032SQ<br>BC6032P<br>BC6033SQ<br>BC6033P|**l Type**<br>**Pressure**<br>**Plate w/**<br>**Quick**<br>**Connect***<br>BC6031PQ<br>BC6032PQ<br>BC6033PQ BC6033B|**Box**<br>**Lug**<br>BC6031B<br>BC6032B<br>BC6033PQ BC6033B|**Poles**<br>1<br>2<br>3|
|---|---|---|---|---|
## **BCCM Series**
**Description:** 3-pole fuse block for use with (2) Class CC fuses and (1)[13] ⁄32” x 1[1] ⁄2” fuse
## **Specifications**
**Description:** Supplementary fuse blocks for use with any[13] ⁄32” x 1[1] ⁄2” fuses (Bussmann KTK, PVM, FNQ, FNM, BAF, PV, and AGU).
**Dimensions:** See Data Sheet 1104 **Poles:** 1 to 3
**DIN-Rail Adapters:** See page 413 for DRA-1 & DRA-2
**Ratings:**
Volts: — 600Vac/dc
Amps: —[1] ⁄10-30A SCCR:— 10kA RMS Sym.
**Agency Information:** CE, UL Recognized (Guide IZLT2, File E14853), CSA (Class 6225-01, File 47235).
**Flammability Rating:** UL 94V0.
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|||
|---|---|---|---|---|
||**Terminal Type**||||
|**Screw**|**Pressure**||||
|**with**<br>**Quick**<br>**Connect***<br>BM6031SQ<br>BM6032SQ<br>BM6033SQ|**Plate w/**<br>**Quick**<br>**Connect***<br>BM6031PQ<br>BM6032PQ<br>BM6033PQ||**Box**<br>**Lug**<br>BM6031B<br>BM6032B<br>BM6033B|**Poles**<br>1<br>2<br>3|
## **Recommended Cover Puller**
- PF1-WH (White) • PF1-BK (Black)
## **Specifications**
**Description:** Class G fuse blocks for use with Class G fuses (Bussmann SC). **Dimensions:** See Data Sheet 1106
**Poles:** 1 to 3
## **Ratings:**
Volts: — 600Vac/dc (0-20A)
- 480Vac/dc (25-60A)
Amps: — 1-60A (See Catalog Numbers table)
SCCR: — 100kA RMS Sym.
**Agency Information:** CE, UL Listed 35-60A (Guide IZLT, File E14853), UL Recognized 1-30A, (Guide IZLT2, File E14853), CSA (Class 6225-01, File 47235). **DIN-Rail Adapters:** See page 413 for DRA-1 & DRA-2.
## **Catalog Numbers**
|||**Terminal Type**|**Terminal Type**|||
|---|---|---|---|---|---|
|**Screw**|**Pressure**|||||
|**with**|**Plate w/**||**Box Lug**|||
|**Quick**|**Quick**|**Box**|**w/retaining**|||
|**Connect***|**Connect***|**Lug**|**clip**|**Amps**|**Poles**|
|BG3011SQ|BG3011PQ|BG3011B|—|1|1|
|BG3012SQ|BG3012PQ|BG3012B|—|to<br>1-15|2|
|BG3013SQ|BG3013PQ|BG3013B|—|15|3|
|BG3021SQ|BG3021PQ|BG3021B|—|20|1|
|BG3022SQ<br>BG3023SQ|BG3022PQ<br>BG3023PQ|BG3022B<br>BG3023B|—<br>—|20|2<br>3|
|BG3031S<br>BG3032S<br>BG3033S|BG3031P<br>BG3032P<br>BG3033P|BG3031B<br>BG3032B<br>BG3033B|—<br>—<br>—|25<br>to<br>30<br>25-30|1<br>2<br>3|
|—<br>—|—<br>—|—<br>—|G30060-1CR<br>G30060-2CR|35<br>to<br>35-60|1<br>2|
|—|—|G30060-3C|G30060-3CR|60|3|
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Terminal**<br>**Type**|
|---|---|
|BCCM6033SQ|Screw with Quick-Connect*|
|BCCM6033PQ|Pressure Plate w/Quick-Connect*|
*Quick-connect terminal rated for 20A max.
## **Recommended Cover Puller**
- PF1-WH (White)
- PF1-BK (Black)
## **Recommended Cover Puller**
- PF1-WH (White)
- PF1-BK (Black)
**Data Sheet: 1104**
**Data Sheet: 1106**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**305**
**Fuse Holders and Blocks**
## **Modular Fuse Blocks**
## **BH Series**
**==> picture [248 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Modular Type Fuse blocks for Class H &<br>J Fuses<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** 3-Pole only, modular type fuse blocks for Class H & J fuses with standard reinforced retaining clips. **Ratings:**
## **Specifications**
**Description:** For use with Bussmann high speed fuses. **Ratings:**
- SCCR: — 200kA RMS Sym. or fuse IR, whichever is lower.
**Agency Information:** CE, UL Recognized, Guide EZLT2, File No. E14853 up to 700V, CSA Certified, Class 6225-01, File No. 47235 up to 700V.
## **BH Series Features and Benefits**
- BH fuse blocks provide a wide range of mounting configurations for Bussmann high speed fuses.
- BH fuse blocks have a Short-Circuit Current Rating of any installed fuse up to 200kA RMS Sym.
- Volts: — 250V (0-60A See Catalog Numbers table) — 600V (35-60A See Catalog Numbers table)
- Amps: — 0-60A @ 250Vac/dc (See Catalog Numbers table) — 35-60A@600V (See Catalog Numbers table)
SCCR: — Class J 200kA, Class H 10kA
**Agency Information:** CE, UL Recognized, Guide IZLT2, File E14853, CSA Certified, Class 6225-01, File 47235.
## **Class H & J Features and Benefits**
• H & J modular fuse blocks provide three pole 30 and 60 amp ratings for specific client requirements for separate line and load fuse clip configurations.
## **Typical Applications**
- Up to 60A, space confined, control circuits
## **Typical Applications**
- Solid State Control Circuits
|• Solid State Control Circuits|• Solid State Control Circuits|||||**Catalog Numbers**|**Catalog Numbers**||||
|---|---|---|---|---|---|---|---|---|---|---|
|• VFDs||||||**Fuse**||||**Fig.**|
|• UPS Systems|||||**Screw**<br>11241-3SR*|**Pressure Plate Class**<br>11241-3PR*<br>H|**Volts**<br>250<br>~~250~~||**Amps**<br>60<br>~~60~~|**No.**<br>1|
|**Catalog Numbers**<br>BH-0001<br>BH-0122<br>BH-0002<br>BH-1001<br>BH-0003<br>BH-1002<br>BH-0111<br>BH-1003<br>BH-0112<br>BH-1131<br>BH-0113<br>BH-1132<br>BH-0121<br>BH-1133|BH-2001<br>BH-2002<br>BH-2003<br>BH-2031<br>BH-2032<br>BH-2033<br>BH-3003|BH-3004<br>BH-3033<br>BH-3144<br>BH-3145|||11242-3SR<br>11242-3PR<br>11241-3SR<br>11241-3PR<br>600<br>11242-3SR**<br>11242-3PR**<br>11239-3SR<br>11239-3PR<br>11240-3SR**<br>11240-3PR**<br>11241-3SR<br>11241-3PR<br>J<br>600<br>11239-3SR*<br>11239-3PR*<br>Note: Order two blocks per fuse (matched or mixed.)<br>*11239 and 11241 have wire terminals and mounting holes located under fuse. (Figure 1)<br>~~H~~<br>~~J~~<br>~~600~~|||35<br>60<br>35<br>60<br>*11239 and 11241 have wire terminals and mounting holes located under fuse. (Figure 1)<br>~~60~~<br>~~35~~||2<br>1<br>2<br>1<br>2<br>1<br>1<br>*11239 and 11241 have wire terminals and mounting holes located under fuse. (Figure 1)|
- VFDs
- UPS Systems
Note: Order two blocks per fuse (matched or mixed.) *11239 and 11241 have wire terminals and mounting holes located under fuse. (Figure 1)
**11240 and 11242 have wire terminals and mounting holes located at end of fuse. (Figure 2)
**Refer to the data sheet numbers below for the catalog code description information.**
**Data Sheet: (BH-0) 1200; (BH-1) 1201; (BH-2) 1202; (BH-3) 1203**
Figure 1
Figure 2
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**306**
**Fuse Holders and Blocks**
## **Box Cover Units for Plug Fuses**
## **SOU, SRU, SSN, SSU, SOW, SRW, SSW, SOX, SRX, SSX, SOY, SRY, SSY, SSY-RL, SSY-L, STY, SCY & SOY-B**
## **Specifications**
**Description:** Box covers for standard electrical boxes that provide fused outlet, fused switch or circuit fuse protection. **Ratings:**
Volts: — 125V/250V (See Catalog Numbers table) Amps: — 0-15A (See Catalog Numbers table)
**Agency Information:** CE, See Catalog Numbers table.
## **Features/Benefits**
- Bussmann Box Cover Units provide a low-cost method of controlling and protecting small motors when used with Bussmann Type T, Fusetron[™] , dual-element fuses.
- Provide low-cost supplementary protection and disconnection of 125V or less, single phase circuits.
## **Typical Applications**
- Fractional Horsepower, 125 Volt Single-Phase Motor Circuits
- General 125 Volt Supplemental Circuits
**==> picture [194 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
SOU SRU SSU<br>STY<br>**----- End of picture text -----**<br>
SSN
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Type Box**<br>~~a~~|**Fuse holder3**<br>~~a~~|**Fuse holder3**<br>~~a~~|**Receptacle**<br>**Outlet to Load**|**Receptacle**<br>**Outlet to Load**|**Switch**<br>**Control1**|**Switch**<br>**Light2**|**Motor**<br>**Size**<br>**(Max)**|**General Data**|**Agency4**<br>**Listing/**<br>**Certification**|
|---|---|---|---|---|---|---|---|---|---|---|
|||**Single **<br>~~a~~|**Double**|**125V**|**250V**||||||
|SOU|**Type Box**<br>~~a~~<br>~~a~~|**Single**<br>X<br>~~a~~<br>~~a~~<br>~~a~~|~~a~~||||**Light**|**(Max)**<br>3⁄4hp|125V, 15A|UL, CSA|
|SRU|21⁄4"Handy<br>21⁄4"Handy<br>~~a~~|X<br>~~a~~<br>~~a~~|~~a~~|X||||hp<br>1⁄2hp|125V, 15A|UL|
|SSU<br>~~Bo~~|Handy<br>~~a~~<br>~~Bo~~|X<br>~~a~~<br>~~A~~<br>|~~a~~<br>|||X<br>||hp<br>1⁄2hp<br>|125Vac, (do not use on dc), 15A<br>|UL, CSA|
|SOW<br>~~Bo~~|~~a~~<br>~~Bo~~|X<br>~~a~~<br>~~A~~<br>~~ee~~|~~a~~<br>~~ee~~|~~ee~~|~~ee~~|~~ee~~|~~ee~~|hp<br>3⁄4hp<br>~~ee~~|125Vac, (do not use on dc), 15A<br>125V, 15A<br>~~ee~~|UL, CSA|
|SRW<br>~~Bo~~|23⁄4"Switch<br>23⁄4"Switch<br>~~Bo ~~|X<br>~~A~~<br> ~~ee~~<br>~~a~~|~~ee~~<br>|X<br>~~ee~~<br>|~~ee~~<br>|~~ee~~<br>|~~ee~~<br>|hp<br>1⁄2hp<br>~~ee~~<br>|125V, 15A<br>~~ee~~<br>|UL|
|SSW<br>~~Bo~~|~~Bo ~~|X<br>~~A~~<br> <br>~~aPo~~|~~Po~~|~~Po~~|~~Po~~|X<br><br>~~Po~~|~~Po~~|hp<br>1⁄2HP<br><br>~~Po~~|125Vac, (do not use on dc), 15A<br><br>~~Po~~|UL, CSA|
|SOX<br>~~Bo~~|~~Bo ~~<br>~~a~~|X<br>~~A~~<br> <br>~~Po~~<br>~~a~~<br>~~a~~|~~Po~~<br>~~a~~|~~Po~~|~~Po~~|~~Po~~|~~Po~~|3⁄4hp<br><br>~~Po~~|125Vac, (do not use on dc), 15A<br>125V, 15A<br><br>~~Po~~|UL, CSA|
|SRX|4"Octagon<br>4"Octagon<br>~~a~~|X<br>~~a~~<br>~~a~~|~~a~~|X||||hp<br>1⁄2hp|125V, 15A|UL|
|SSX|Octagon<br>~~a~~|X<br>~~a~~<br>~~A~~|~~a~~|||X||hp<br>1⁄2hp|125Vac, (do not use on dc), 15A|UL, CSA|
|SOY|~~a~~|X<br>~~a~~<br>~~A~~<br>~~a~~|~~a~~|||||hp<br>3⁄4hp|125Vac, (do not use on dc), 15A<br>125V, 15A|UL, CSA|
|SRY||X<br>~~a~~<br>~~a~~||X<br>||||hp<br>1⁄2hp<br>|125V, 15A<br>|UL|
|SSY||X<br>~~aPo~~|~~Po~~|~~Po~~|~~Po~~|X<br>~~Po~~|~~Po~~|hp<br>1⁄2hp<br>~~Po~~|125Vac, (do not use on dc), 15A<br>~~Po~~|UL, CSA|
|SSY-RL|4"Square<br>4"Square|X<br>~~Po~~<br>~~a~~|~~Po~~|X<br>~~Po~~|~~Po~~|X<br>~~Po~~|X<br>~~Po~~|hp<br>1⁄2hp<br>~~Po~~|125Vac, (do not use on dc), 15A<br>125Vac, (do not use on dc), 15A<br>~~Po~~|—|
|STY3|Square<br>Square|~~a~~|X|||X||hp<br>1⁄2hp|125Vac, (do not use on dc), 15A<br>125Vac, (do not use on dc), 15A|UL|
|SCY|||X|||X(2)||hp<br>1⁄2hp (2)|125Vac, (do not use on dc), 15A<br>125Vac, (do not use on dc),<br>can protect two motors, 15A|UL|
|SOY-B<br>~~Po~~|~~Po~~|~~a~~|X|||||3⁄4hp|can protect two motors, 15A<br>125V, protects two motors, 15A|UL|
|SSN<br>~~Po~~|Single Gang<br>~~Po~~|X<br>~~a~~||X||X||hp<br>1⁄2hp|125V, protects two motors, 15A<br>Weatherproof model, 15A|UL|
- 1 Switch turns power to fused load OFF or ON.
- 2 Switch light indicates power to load (dark when switch OFF or fuse open).
- 3 Double pole switch opens both sides of circuit. Can be used for two separate motors with common switch or a single motor ([3] ⁄4Hp, 250Vac max.).
- 4 UL Guide JAMZ, File IE6491; CSA Class 6225-01, File 47235.
**Data Sheet: 1129**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**307**
**Fuse Holders and Blocks**
## **In-line Fuse Holders for[1] ⁄4" x[7] ⁄8" to 1[1] ⁄4" Fuses**
**HFB & HFB-10**
**==> picture [28 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HHB<br>**----- End of picture text -----**<br>
**==> picture [29 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HRK<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Water-resistant in-line fuse holder for[1] ⁄4" x 1[1] ⁄4" fuses.
**Dimensions:** See Dimensions illustration.
**Construction:** Thermoplastic rubber body with tin-plated, copper contacts. **Ratings:**
Volts: — 32V Amps: — 30A max
## **Catalog Numbers**
**Catalog Numbers Description** HFB* Standard Pack (10-in) BK/HFB Bulk Pack (100-in) BK/1A2294 HFB Replacement Contact Clip 1A2294-01 HFB-10** Replacement Contact Clip
*HFB accepts #12 to #18 wire leads (not provided). See Data Sheet for recommended crimp tools. **HFB-10 accepts #10 wire leads (not provided). See Data Sheet for recommended crimp tools.
## **Features/Benefits**
- Simple assembly with one-piece thermoplastic (important information molded into body)
- High visibility yellow color for easy identification in dark or hard-to-access locations
- Ideal for shock and vibration environments; withstands many organic solvents; temperature range - 40/+150°C
## **Typical Applications**
- Supplemental, Low Voltage, Low Amperage Control Circuits
## **Dimensions - in (mm)**
**==> picture [100 x 47] intentionally omitted <==**
**----- Start of picture text -----**<br>
3"<br>(76.2mm)<br>0.75"<br>(19.1mm)<br>**----- End of picture text -----**<br>
## **Specifications**
## **Specifications**
**Description:** Universal in-line fuse holder for[1] ⁄4" x[7] ⁄8", 1" and 1[1] ⁄4" fuses.
**Description:** Universal in-line fuse holder for[1] ⁄4" x[7] ⁄8" to 1[1] ⁄4" fuses.
**Dimensions:** See Dimensions illustration.
**Dimensions:** See Dimensions illustration.
**Construction:** 8" (203mm) #14 lead wires.
**Construction:** Nylon body with tinplated, copper contacts.
## **Ratings:**
## **Ratings:**
Volts: — 32V Amps: — 30A max
Volts: — 32V Amps: — 15A max
**Flammability Rating:** UL 94V2.
## **Features and Benefits**
**Pull Force:** 5lbs minimum to separate fuse holder housing with fuse installed.
- HRK Universal in-line fuse holder for 1 7 1 ⁄4" x ⁄8", 1" and 1 ⁄4" fuses with #14
- lead wires.
## **Features and Benefits**
- RoHS compliant
- HHB Universal in-line fuse holder for 1 7 1 ⁄4" x ⁄8", 1" and 1 ⁄4" fuses.
## **Typical Applications**
- Supplemental, Low Voltage, Low Amperage Control Circuits
## **Typical Applications**
- Supplemental, Low Voltage, Low Amperage Control Circuits
## **Catalog Number**
**Catalog Amp Number Rating Volts Fuse Description** HRK-R* 15 32 1⁄4" diameter fuses of different lengths.
**Catalog Numbers Holder — without leads* - RoHS compliant Catalog Numbers Description** HHB-R Standard Pack (10-in) BK/HHB-R Bulk Pack (100-in)
*Three springs furnished with fuse holder to accommodate different length[1] ⁄4" fuses.
*Accepts #12 to #16 wire leads (not provided with basic fuse holder). See Data Sheet for recommended crimp tools. **Dimensions - in (mm)**
**Holder — with pre-attached #14 Insulated lead wires - Not RoHS compliant unless** ~~2.19"~~ **noted** (55.6mm) **Catalog Numbers19" Length 8" Length WireColor** (19.1mm)0.75" BK/HHB-Y419 BK/HHB-Y408 Yellow 0.69" BK/HHB-R419 BK/HHB-R408** Red (17.5mm) BK/HHB-B419 BK/HHB-B408 Black ~~1.56"~~ 0.38" ~~ile~~ (39.7mm) (9.5mm) **RoHS compliant. **Dimensions - in (mm)**
**Fuse Length Fuse Holder Length “L”** 7⁄8" (AGW) 2.100 Max 1" (AGX) 2.250 Max ~~1~~[1] ~~⁄4~~ " ~~(AGC, MDL) 2.420 Max~~
**==> picture [4 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
L<br>**----- End of picture text -----**<br>
0.53" (13.5mm)
**Data Sheet: 2102**
**Data Sheet: 2103**
**Data Sheet: 2111**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**308**
**Fuse Holders and Blocks**
## **In-line Fuse Holders**
## **HR and HM Series**
**==> picture [69 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HFA Series<br>**----- End of picture text -----**<br>
**==> picture [70 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HHT Series<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** In-line fuse holders for SFE and[1] ⁄4" dia. x various length fuses. **Dimensions:** See Dimensions illustration.
## **Specifications**
## **Specifications**
**Ratings:**
**Description:** In-line fuse holders for 5 x 15mm or 5 x 20mm fuses. **Dimensions:** See Dimensions illustration.
**Description:** In-line water-resistent fuse holders for[1] ⁄4" x 1[1] ⁄4" fuses. **Dimensions:** See Dimensions illustration.
Volts: — 32V Amps: — 20A
## **Features and Benefits**
- HR and HM Universal in-line fuse holder for SFE and various length[1] ⁄4" diameter fuses with #14 lead wires.
## **Ratings:**
**Construction:** Black thermoplastic body with brass contacts, wire: 16 AWG, red.
Volts: — 250V Amps: — 20A
## **Ratings:**
## **Typical Applications**
Volts: — 32V
- Supplemental, Low Voltage, Low Amperage Control Circuits
Refer to data sheet for recommend crimp tools
Amps: — 5A (5 x 15mm)
— 10A (5 x 20mm) **Catalog Numbers Catalog Numbers CatalogNumbers FuseIncludes & SizeWire Length CatalogNumbers Terminals Catalog Numbers** HRJ* SFE-20 HFA Crimp #12 - #16 **Catalog Number Fuse Size** HRI SFE-14 HFA-HH* 1⁄4" Quick Connect HHT 5 x 15mm & 5 x 20mm HRH SFE-9 *No UL Recognition. HRE SFE-7[1] ⁄2 19” of #14 HRG SFE-6 **Data Sheet: 2115 Data Sheet: 2138** HRF SFE-4 HMJHMI ** SFESFE--2014 **HEG Series HEH Series** HMH SFE-9 HME SFE-7[1] ⁄2 8” of #14 HMG SFE-6 HMF SFE-4 * Also available as in-line fuse holder only with lead wire contacts, HRJ-LESS-Fuse. ** Also available as in-line fuse holder only with lead wire contacts, HMJ-LESS-Fuse. HHJ-A For[1] ⁄4" x 1[1] ⁄4" fuse, no wire or fuse ~~a~~ included, accepts #18 - #22 wire. ~~.~~ HHJ-B For[1] ⁄4" x 1[1] ⁄4" fuse, no wire or fuse **Specifications Specifications** included, accepts #12 - #16 wire. **Description:** Single-pole, non-break- **Description:** Single-pole, nonHHI-B For[1] ⁄4" x 1[1] ⁄16" fuse, no wire or fuse away, in-line fuse holders for Type SC breakaway, in-line fuse holders for included, accepts #12 - #16 wire. fuses, 480V (or less). Type SC fuses (Also fuse types BBS **Replacement Contacts** & KTQ, nominal size[13] ⁄32" x 1[3] ⁄8").
## **Ratings:**
**Catalog Number Symbol** 9838 HHJ-A 9841 HHJ-B
## **Ratings:**
Volts: — 600V
Volts: — 600V
Amps: — 0-15A
Amps: — 0-20A
**Fuse Size:**[13] ⁄32" x 1.31"
## **Dimensions - in (mm)**
**Agency Information:** CSA - 15A.
**Catalog Number** HEG-AA
**==> picture [144 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.19"<br>(55.6mm)<br>0.75"<br>(19.1mm)<br>0.69"<br>(17.5mm)<br>1.56" 0.38"<br>(39.7mm) (9.5mm)<br>**----- End of picture text -----**<br>
**Catalog Numbers** HEH-AA, HEH-AD
## **Optional Boots:**
**Optional Boots:** 2A0660 Single Conductor 2A0661 Two Conductor
2A0660 Single Conductor 2A0661 Two Conductor
**Data Sheet: 2124**
**Data Sheet: 2124**
**Data Sheet: 2122**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**309**
**Fuse Holders and Blocks**
## **Tron[™] In-line Fuse Holders**
**HEC Series Specifications** i **Description:** Single-pole, non-breakaway, in-line fuse holders for Type SC-25, & SC-30 fuses, size 13⁄32" x 1 5⁄8".
## **Ratings:**
Volts: — 480V Amps: — 0-30A
**Catalog Numbers** HEC-AA, HEC-RW-RLB-R
**Optional Boots:** 2A0660 Single Conductor 2A0661 Two Conductor
**HEJ Series HEB Series Specifications** AN **Specifications Description:** Single-pole, **Description:** non-breakaway, in-line fuse in-line fuse holders for any holders for Type SC and Type 13⁄32" x 1 1⁄2" fuses (typically⁄32" x 1 1⁄2" fuses (typically32" x 1 1⁄2" fuses (typically" x 1 1⁄2" fuses (typically1⁄2" fuses (typically⁄2" fuses (typically2" fuses (typically" fuses (typically HVW fuses, size[13] ⁄32" x 2[1] ⁄4". fuse types: BAF, FNM, FNQ, **Ratings:** and KTK[[1]] ⁄1010 - 30A). Volts: — 480V **Ratings:** Amps: — 35-60A Type SC Volts: — 600V —[1] ⁄2-6A Type HVW Amps: — 0-30A
**Description:** Single-pole in-line fuse holders for any 13⁄32" x 1 1⁄2" fuses (typically⁄32" x 1 1⁄2" fuses (typically32" x 1 1⁄2" fuses (typically" x 1 1⁄2" fuses (typically1⁄2" fuses (typically⁄2" fuses (typically2" fuses (typically" fuses (typically fuse types: BAF, FNM, FNQ, and KTK[[1]] ⁄1010 - 30A).
**Catalog Numbers** See Page 311
## **Catalog Numbers**
HEJ-AA, HEJ-AB, HEJ-AC, HEJ-BB, HEJ-JJ, HEJ-JK, HEJ-LL, HEJ-LLB, HEJ-CC, HEJ-DD, HEJ-WW, HEJ-PP, HEJ-QQ
## **Optional Boots:**
2A0660 Single Conductor 2A0661 Two Conductor
## **Optional Boots:**
**==> picture [119 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
HEX Series<br>Specifications OF<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Double-pole inline fuse holders for[13] ⁄32" x 1[1] ⁄2" fuses (typically fuse types BAF, FNM, FNQ, and KTK 1 ⁄10 - 30A).
**Ratings:**
Volts: — 600V Amps: — 0-30A
## **Catalog Numbers**
HEX-AA, HEX-AB, HEX-AC, HEX-AD, HEX-AE, HEX-AW, HEX-AW-DRLC-A, HEX-AW-DRYC, HEX-AW-RLC-A, HEX-AW-RYC, HEX-AY, HEX-BB, HEX-CC, HEX-JJ, HEX-JK, HEX-JW-DRYC, HEX-KK
2A0660 Single Conductor 2A0661 Two Conductor
## **Data Sheet: 2124**
**Data Sheet: 2123**
**HEZ Series HEY Series** +e **Specifications Specifications**
**Description:** Waterproof (IPX7), single-pole Class CC in-line fuse holders. Holds Bussmann fuse types: LP-CC, FNQ-R and KTK-R.
**Description:** Double-pole
in-line fuse holders for KTKR fuses with optional breakaway receptacle, polarized, and accepting Class CC branch circuit fuses (Bussmann KTK-R, FNQ-R & LP-CC; 600V or less, 200kA IR).
## **Ratings:**
Volts: — 600V (or less) Amps: — Up to 30A*
**Ratings:**
## **Conductors: Lineside & Loadside****
Volts: — 600V Amps: — 0-30A
#12 to #8 Crimp terminal #12 to #3 Setscrew terminal
## **Catalog Numbers**
*Amp rating limited by conductor size and fuse sizing when used with insulating boots
HEY-AA, HEY-AB, HEY-AC, HEYAD, HEY-AE, HEY-AL, HEY-AWDRLC-A, HEY-AW-DRLC-B, HEYAW-DRYC, HEY-BB, HEY-JJ
**See details in non-breakaway and breakaway specifications
**Data Sheet: 2126**
## **Data Sheet: 2130**
**Data Sheet: 2127**
**HET Series**
## **Specifications**
**Description:** Single-pole in-line fuse holders for 13⁄32" x 1 1⁄2" fuses with a permanently solid neutral identified by white plastic coupling nut.
## **Catalog Numbers**
HET-AA, HET-AB, HET-AW, HETAW-RLC-A, HET-AW-RLC-B, HETAW-RLC-C, HET-AW-RLC-J, HETAW-RYC, HET-BB, HET-BW-RLC-B, HET-BW-RYC, HET-JJ, HET-JK, HET-JW, HET-JW-RLC-J, HET-JWRYC, HET-KK
**Data Sheet: 2125**
**Data Sheet: 2126**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**310**
**Fuse Holders and Blocks**
## **For HEB Holders Only**
Directions: To select complete holder P/N, work from left to right starting with loadside terminal options and then lineside terminal options. Then determine breakaway or non-breakaway style.
|**Loadside Terminal**|**Loadside Terminal**|**Loadside Terminal**|**Loadside Terminal**|**Loadside Terminal**|**Lineside Terminal**|**Lineside Terminal**|**Lineside Terminal**|**Lineside Terminal**|**Lineside Terminal**|**Available P/N’s**|**Available P/N’s**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|**Terminal**<br>**Type**|**Wire Size**|**No. of**<br>**Wires per**<br>**Terminal**|**Solid**<br> **Wire**|**Stranded**<br>**Wire**|**Terminal**<br>**Type**|**Wire Size**|**No. of**<br>**Wires per**<br>**Terminal**|**Solid**<br> **Wire**|**Stranded**<br>**Wire**|**Non-Breakaway**<br>**P/N**<br>**(Boots not included)**|**Breakaway**<br>**P/N**<br>**(Boots included)**|
|Copper #12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||Copper #12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||HEB-AA(1)(2)<br>(3)|HEB-AW-RLC-A(1)(2)<br>(3)|
|Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||Copper<br>#6<br>1<br>Y<br>Y<br>Crimp<br>#10<br>2<br>Y<br>Y|||||HEB-AB(2)<br>|HEB-AW-RLC-B<br>|
|Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||Copper<br>#4<br>1<br>N<br>Y<br>Crimp<br>#8<br>2<br>Y<br>Y<br>(4)|||||HEB-AC(2)|HEB-AW-RLC-C(4)|
|Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||<br>Copper<br>#2<br>1<br>N<br>Y<br>Crimp<br>#6<br>2<br>Y<br>Y|||||HEB-AD(2)|N/A|
|Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||Copper<br>2/0<br>1<br>N<br>Y<br>Crimp<br>#3<br>2<br>N<br>Y|||||HEB-AE(2)|N/A|
|Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||Copper<br>#12 to #3<br>1<br>Y<br>Y<br>Setscrew|||||HEB-AJ|HEB-AW-RLC-J|
|Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||Copper<br>#12 to #3<br>2<br>Y<br>Y<br>Setscrew|||||HEB-AK|HEB-AW-RYC|
|Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||Aluminum<br>#12 to #2<br>1<br>Y<br>Y<br>Setscrew|||||HEB-AL|HEB-AW-RLA|
|Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||Aluminum<br>#12 to #2<br>2<br>Y<br>Y<br>Setscrew|||||HEB-AY|HEB-AW-RYA|
|Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||Aluminum<br>#1, #2<br>1<br>N<br>Y<br>Crimp|||||HEB-AR|N/A|
|Copper<br>#6<br>1<br>Y<br>Y<br>Crimp<br>#10<br>2<br>Y<br>Y|||||Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||HEB-BA(2)|HEB-BW-RLC-A|
|Copper<br>#6<br>1<br>Y<br>Y<br>Crimp<br>#10<br>2<br>Y<br>Y|||||Copper<br>#6<br>1<br>Y<br>Y<br>Crimp<br>#10<br>2<br>Y<br>Y|||||HEB-BB(2)|HEB-BW-RLC-B|
|Copper<br>#6<br>1<br>Y<br>Y<br>Crimp<br>#10<br>2<br>Y<br>Y|||||Copper<br>#4<br>1<br>N<br>Y<br>Crimp<br>#8<br>2<br>Y<br>Y|||||HEB-BC(2)|N/A|
|Copper<br>#6<br>1<br>Y<br>Y<br>Crimp<br>#10<br>2<br>Y<br>Y|||||Copper<br>#2<br>1<br>N<br>Y<br>Crimp<br>#6<br>2<br>Y<br>Y|||||HEB-BD(2)|N/A|
|Copper<br>#4<br>1<br>N<br>Y<br>Crimp<br>#8<br>2<br>Y<br>Y|||||Copper<br>#4<br>1<br>N<br>Y<br>Crimp<br>#8<br>2<br>Y<br>Y|||||HEB-CC(2)|N/A|
|Copper<br>#2<br>1<br>N<br>Y<br>Crimp<br>#6<br>2<br>Y<br>Y|||||Copper<br>#2<br>1<br>N<br>Y<br>Crimp<br>#6<br>2<br>Y<br>Y|||||HEB-DD(2)|N/A|
|Copper<br>#20, #18<br>1<br>Y<br>Y<br>Crimp|||||Copper<br>#12 to #8<br>1<br>Y<br>Y<br>Crimp<br>#12<br>2<br>Y<br>Y|||||HEB-ZA|N/A|
|Copper<br>#12 to #3<br>1<br>Y<br>Y<br>Setscrew|||||Copper<br>#12 to #3<br>1<br>Y<br>Y<br>Setscrew|||||HEB-JJ|HEB-JW-RLC-J|
|Copper<br>#12 to #3<br>1<br>Y<br>Y<br>Setscrew|||||Copper<br>#12 to #3<br>2<br>Y<br>Y<br>Setscrew|||||HEB-JK|HEB-JW-RYC|
|Copper<br>#12 to #3<br>1<br>Y<br>Y<br>Setscrew|||||Aluminum<br>#12 to #2<br>1<br>Y<br>Y<br>Setscrew|||||HEB-JL|N/A|
|Copper<br>#12 to #3<br>1<br>Y<br>Y<br>Setscrew|||||Aluminum<br>#12 to #2<br>2<br>Y<br>Y<br>Setscrew|||||HEB-JY|N/A|
|Aluminum<br>#12 to #2<br>1<br>Y<br>Y<br>Setscrew|||||Aluminum<br>#12 to #2<br>1<br>Y<br>Y<br>Setscrew|||||HEB-LL|HEB-LW-RLA|
|Aluminum<br>#8<br>1<br>N<br>Y<br>Crimp<br>#6<br>1<br>Y<br>N|||||Aluminum<br>#8<br>1<br>N<br>Y<br>Crimp<br>#6<br>1<br>Y<br>N|||||HEB-NN|N/A|
|Aluminum<br>#6<br>1<br>N<br>Y<br>Crimp<br>#4<br>1<br>Y<br>N|||||Aluminum<br>#6<br>1<br>N<br>Y<br>Crimp<br>#4<br>1<br>Y<br>N|||||HEB-PP(2)<br>|N/A|
|Aluminum<br>#3, #4<br>1<br>N<br>Y<br>Crimp<br>#2<br>1<br>Y<br>N|||||Aluminum<br>#3, #4<br>1<br>N<br>Y<br>Crimp<br>#2<br>1<br>Y<br>N|||||HEB-QQ(2)|N/A|
|Aluminum<br>#1, #2<br>1<br>N<br>Y<br>Crimp|||||Aluminum<br>#1, #2<br>1<br>N<br>Y<br>Crimp|||||HEB-RR(2)|N/A|
|Aluminum<br>1/0<br>1<br>N<br>Y<br>Crimp|||||Aluminum<br>1/0<br>1<br>N<br>Y<br>Crimp|||||HEB-TT(2)|N/A|
|SolidTerminal #8 to #12<br>1<br>Y<br>N<br>for aluminum<br>connector<br>#10 to #14<br>1<br>N<br>Y|||||SolidTerminal #8 to #12<br>1<br>Y<br>N<br>for aluminum<br>connector<br>#10 to #14<br>1<br>N<br>Y|||||HEB-SS|N/A|
|**Data Sheet: 21**<br>(1)UL Recognized, Guide IZLT2, File E14853<br>(2)CSA Certified, Class 6225-01, File 47235<br>(3)CE<br>(4)HEB-AW-RLC-C is for (1) #4 stranded wire only.<br>Contact your local Bussmann representative for other possible<br>terminations not listed.<br>Insulating boots for single conductor-2A0660<br>Dual conductor-2A0661||||||||||||
**Data Sheet: 2127**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**311**
**Fuse Holders and Blocks**
## **Panel Mounted Fuse Holders for 5 x 20mm Fuses**
## **HTC-35M**
## **Ratings:**
Volts: — 250Vac Amps: — 10A UL, 6.3A VDE **Fuse Access:** Threaded cap
## **HTC-40M**
## **Ratings:**
Volts: — 250Vac Amps: — 10A UL, 6.3A VDE **Fuse Access:** Screwdriver slot
## **HTC-55M**
## **Ratings:**
Volts: — 250Vac Amps: — 10A UL, 6.3A VDE **Fuse Carrier:** Bayonet type
## **HTC-70M**
**Ratings:**
Volts: — 250Vac Amps: — 10A UL, 6.3A VDE **Fuse Carrier:** Bayonet type
**==> picture [334 x 328] intentionally omitted <==**
**----- Start of picture text -----**<br>
37.5mm 3.0x0.51mm 12.00mm +0.0–0.1<br>Ø16mm<br>4mm<br>5.5mm 11mm Data Sheet: 2110<br>37.5mm 3.0x0.51mm 12.00mm +0.0–0.1<br>6.5mm<br>Data Sheet: 2110<br>36mm 3.0x0.51mm 12.00mm +0.0–0.1<br>Ø16mm<br>0.5mm 4mm<br>5.5mm 11mm Data Sheet: 2110<br>35.5mm 10.2mm 12.00mm +0.0–0.1<br>Ø16mm<br>4.8x0.51mm<br>0.5mm 4mm<br>5.5mm 11mm Data Sheet: 2110<br>Ø15mm +0.0–0.1<br>12.70mm<br>Ø22mm Ø15mm +0.0–0.1<br>12.70mm<br>Ø15mm +0.0–0.1<br>12.70mm<br>Ø15mm +0.0–0.1<br>12.70mm<br>**----- End of picture text -----**<br>
## **Specifications**
**Terminals: Molded Materials:**
Tin-plated brass.
High temperature thermoplastic that meets the flammability ratings of UL 94V0; Glow Wire Test: 960°C per IEC 60695-2-1.
**Solderability:** In accordance with IEC 68-2-20. **Agency Information:** cURus, VDE **Electrical:** Contact Resistance: ≤ 10 megohm; Insulation Resistance: ≥ 10MΩ; Dielectric Strength ≥ 2000Vac. **Shock Safety:** PC2 (fuse holders). **Packaging:** Standard Qty 10 (No Prefix), Bulk Qty 100 (Prefix Catalog Number with BK/).
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**312**
**Fuse Holders and Blocks**
## **Panel Mounted Fuse Holders for[1] ⁄4" x 1[1] ⁄4" Fuses**
**==> picture [123 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
HKP, HKP-L, HKP-W<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Standard fuse holders. **Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 250V Amps: — 30A **Catalog Numbers Catalog Fuse Numbers Description** HKP — HKP-L HKP w/ 2250V stand-off barrier HKP-W HKP w/ drip-proof knob
## **Dimensions - in (mm)**
## **Data Sheet: 2106**
**HKP-BBHH, HKP-HH and HKP-LW-HH**
## **Specifications**
" **Description:** Fuse holders with[1] ⁄4 quick-connects.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
**==> picture [157 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
Volts: — 250V<br>Amps: — 15A<br>Catalog Numbers<br>Catalog Fuse<br>Numbers Description<br>HKP-BBHH HKP w/ [1] ⁄4" quick-connects, nut and washer<br>assembled.<br>HKP-HH HKP w/ [1] ⁄4" quick-connect.<br>HKP-LW-HH HKP w/ drip-proof knob, 2250V stand-off<br>barrier and [1] ⁄4" quick-connects.<br>**----- End of picture text -----**<br>
## **Dimensions - in (mm)**
**==> picture [71 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data Sheet: 2106<br>**----- End of picture text -----**<br>
**==> picture [51 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HKP-OO<br>**----- End of picture text -----**<br>
**Specifications Description:** Snap-lock fuse holders. **Dimensions:** See Dimensions illustration.
## **Ratings:**
**==> picture [141 x 227] intentionally omitted <==**
**----- Start of picture text -----**<br>
Volts: — 250V<br>Amps: — 30A<br>Catalog Numbers<br>Catalog Fuse<br>Number Description<br>HKP-OO HKP with snap-lock<br>Dimensions - in (mm)<br>.75" 1.56"<br>(19.1mm) (39.7mm)<br>eee (21.7mm).855" 1.17" | ZI ma |<br>Ns .800" i = |_|= ‘<br>(20.3mm)<br>Punched Mounting Hole<br>.890"<br>(22.6mm)<br>.811"<br>(20.6mm)<br>FUSE FUSE<br>ESUF<br>**----- End of picture text -----**<br>
**==> picture [71 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data Sheet: 2106<br>**----- End of picture text -----**<br>
## **Specifications**
**Terminals:** Bayonet-type knob. Vibration resistant. For panels up to[5] ⁄16" (7.9mm) thick. **Agency Information:** CE (HKP, HKP-L, HKP-W, HKP-OO), UL Recognized — Guide IZLT2, File E14853, CSA Certified — Class 6225-01, File 47235
**Replacement Parts:**
Cap: 9435-1/2 Plastic Nut: BK/1A4287 (100 pieces minimum) Metal Nut: BK/1A4806-2 (100 pieces minimum) Washer: 9732
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**313**
**Fuse Holders and Blocks**
## **Panel Mounted Fuse Holders for 5 x 20mm and[1] ⁄4" x 1[1] ⁄4" Fuses**
## **HTB Series**
## **Specifications**
**Description:** Fuse holders with knob-type carriers. **Dimensions:** See Dimensions illustrations.
**Construction:** High temperature, flame retardant thermoplastic; UL Component Recognized; UL 94V0; mounting nut, spacer-black polycarbonate. Terminals: tin-plated brass.
**Electrical Data:** Insulation resistance (per IEC #257) — 10,000 ohms @ 500Vdc; contact resistance (per IEC #257) — 0.005 ohms Max @ 1A; standoff voltage (per IEC #257) — 480V/Mil @ 0.125” thickness.
**Agency Information:** CE, UL Recognized — Guide IZLT2, File E14853,[1] ⁄4˝ dia fuse @ 20A, 5mm dia fuse @16A @ 250V, CSA — 16A @ 250V Class 6225-01 File 47235; VDE Certified: 136128, HTB-XXM, SEMKO Certification: Ref. #0146149/01, HTB-XXM.
## **Replacement Parts**
**Mounting:** Withstands 15 to 20 Lb-In torque to mounting nut when mounting fuse holder to panel.
**Environmental:** Operating temperature range -55°C to 85°C.
## **Dimensional Data - in (mm)**
|**Knob Type Carrier**<br>Common Dimensions:<br>Length (Knob Type) - 1.69"<br>(42.9mm) Plus In-Line Terminal<br>NOTE: Plus In-Line Terminal|**Knob Type Carrier**<br>Common Dimensions:<br>Length (Knob Type) - 1.69"<br>(42.9mm) Plus In-Line Terminal<br>NOTE: Plus In-Line Terminal|Maximum<br>Panel<br>Thickness|Terminal Options|Terminal Options|Terminal Options|Terminal Options|Carrier Options|Carrier Options|
|---|---|---|---|---|---|---|---|---|
||||Solder/<br>3⁄16" Quick-Connect||1⁄4" Quick-Connect||||
||||In-Line|Rt. Angle|In-Line|Rt. Angle|1⁄4" x 11⁄4" 5 x 20mm<br>(“I” Equals Inches)|" 5 x 20mm<br> (“M” Equals Metric)|
||||||||Knob Knob|Knob Knob|
||||**0.34"**<br>(8.7mm)<br>~~f+|~~|**0.33"**<br>(8.3mm)<br>~~|Th~~|**0.47"**<br>(11.9mm)|**0.45"**<br>(11.5mm)<br>~~J}~~|~~N~~||
|**1.125"**<br>(28.6mm)<br>**0.47"**<br>(11.9mm)<br>**0.09" NOM.**<br>(2.4mm)<br>Bi||0.30”<br>7.62mm|HTB-22I-R<br>~~f+ |~~|HTB-24I-R<br>~~| Th~~|HTB-26I-R|HTB-28I-R<br>~~J}~~|X<br>~~N~~||
||||HTB-22M-R|HTB-24M-R|HTB-26M-R|HTB-28M-R||X|
|**0.69**~~**"**~~<br>(17.5mm)|**0.91"**<br>(23.0mm)|0.125”<br>3.18mm|HTB-42I-R|HTB-44I-R|HTB-46I-R|HTB-48I-R|X||
||||HTB-42M-R|HTB-44M-R|HTB-46M-R|HTB-48M-R||X|
|**0.67"**<br>(17.1mm)|**0.92"**<br>(23.4mm)|0.30”<br>7.62mm|HTB-62I-R|HTB-64I-R|HTB-66I-R|HTB-68I-R|X||
||||HTB-62M-R|HTB-64M-R|HTB-66M-R|HTB-68M-R||X|
|**1.125"**<br>(28.6mm)<br>**0.47"**<br>(11.9mm)||0.125”<br>3.18mm|HTB-82I-R|HTB-84I-R|HTB-86I-R|HTB-88I-R|X||
||||HTB-82M-R|HTB-84M-R|HTB-86M-R|HTB-88M-R||X|
Fuse holders and fuse carriers may be ordered separately.
**Data Sheet: 2119**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**314**
**Fuse Holders and Blocks**
## **Panel Mounted Fuse Holders for 5 x 20mm and[1] ⁄4" x 1[1] ⁄4" Fuses**
## **HTB Series**
**==> picture [514 x 614] intentionally omitted <==**
**----- Start of picture text -----**<br>
HTB Series bi he<br>Dimensional Data - in (mm)<br>Screwdriver Type Carrier Terminal Options<br>Solder/ Carrier Options<br>3⁄16" Quick-Connect 1⁄4" Quick-Connect<br>Maximum 1⁄4" x 1 1⁄4" 5 x 20mm<br>Panel In-Line Rt. Angle In-Line Rt. Angle (“I” Equals Inches) (“M” Equals Metric)<br>Thickness Screwdriver Screwdriver<br>Common Dimensions:<br>(Screwdriver Slotted)<br>1.75" (44.5mm)NOTE: Plus In-Line Terminal (8.7mm) 0.34" (8.3mm) 0.33" (11.9mm) 0.47" (11.5mm) 0.45"<br>0.17" 1.58" 0.30” HTB-32I-R HTB-34I-R HTB-36I-R HTB-38I-R X<br>_ (4.37mm) _| (40.03mm) BEE<br>7.62mm HTB-32M-R HTB-34M-R HTB-36M-R HTB-38M-R X<br>HTB-3<br>es | ee<br>(10.31mm) 0.41" (34.13mm) 1.34" 0.125” HTB-52I-R HTB-54I-R HTB-56I-R HTB-58I-R X<br>3.18mm HTB-52M-R HTB-54M-R HTB-56M-R HTB-58M-R X<br>HTB-5<br>0.17" 1.59"<br>(4.37mm) (40.08mm) 0.125” HTB-92I-R HTB-94I-R HTB-96I-R HTB-98I-R X<br>ibe)<br>HTB-9 3.18mm HTB-92M-R HTB-94M-R HTB-96M-R HTB-98M-R X<br>ey eee<br>Catalog Number Build-A-Code<br>HTB- FUSE CARRIER ONLY<br>S P<br>Packing<br>Blank (Std.) – 10 fuse holders Fuse Carrier Splash Proof<br>in a carton Product I — 1/4˝ x 1 1/4˝ Cap with O-Ring<br>BK – 100 fuse holders in a Symbol M — 5 x 20mm (Optional on Knob<br>Fo FPPR FE<br>cardboard shelf package Holders Only) Packaging Product Fuse Carrier<br>(Blank) – Std. Symbol I — 1/4˝ x 1 1/4˝<br>Body Configuration and Mounting Rear Terminal Configuration BK/ – Bulk FT — Knob Type M — 5 x 20mm<br>Knob Holders 2 — Solder / 3/16˝ Quick-Connect -R (For 20, 40, 60,<br>2 — Low Profile (Rear Panel Hex-Nut) (In-Line) and 80 Series<br>4 — High Profile 4 — Solder / 3/16˝ Quick-Connect Only)<br>6 — * (Front Panel Hex-Nut) (Right Angle) RoHS ST — Screwdriver<br>8 — Low Profile (Snap-In) 6 — 1/4˝ Quick-Connect (In-Line) Compliant Slotted (For 30,<br>Screwdriver Slotted Holders 8 — 1/4˝ Quick-Connect (Right Angle) 50, and 90 Series<br>3 — Low Profile Only)<br>5 — High Profile<br>T 9 — Low Profile (Snap-In) F<br>*Profile varies with panel thickness. Holder installs through rear of panel.<br>**----- End of picture text -----**<br>
**Data Sheet: 2119**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**315**
**Fuse Holders and Blocks**
## **Panel Mounted Fuse Holders for Indicating Type Fuses**
**==> picture [63 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HK Series<br>**----- End of picture text -----**<br>
**==> picture [26 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HLD<br>**----- End of picture text -----**<br>
**==> picture [25 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HJL<br>**----- End of picture text -----**<br>
## **Specifications**
## **Specifications**
## **Specifications**
**Description:** Pin indicating for 1 1 ⁄4" x 1 ⁄4" fuses. **Dimensions:** See Dimensions illustration.
**Description:** Neon lamp indicating for 1 ⁄4" x 1" fuses. **Dimensions:** See Dimensions illustration.
**Description:** Neon and incandescent lamp indicating for[1] ⁄4" x 1[1] ⁄4" fuses **Dimensions:** See Dimensions illustration.
## **Ratings:**
**Ratings:** Volts: — 250V Amps: — 15A
## **Ratings:**
Volts: — 250V Amps: — 15A **Agency Information:** CE, UL Recognized, File E14853, Guide IZLT2.
Volts: — 250V Amps: —15A (HKL, HKL-X) — 20A (HKR, HKT, HKU, HKX) **Agency Information:** CE, UL Recognized, (Guide IZLT2, File E14853), CSA Certified (Class 6225-01, File 47235).
**Agency Information:** None
**Catalog Number Catalog Lamp Knob Number* Volts Color Type** HJL 90 to 250 Clear Oct *Use with AGX or MKB fuses, for panels up to[1] ⁄8" thick.
|**Catalog Numbers**<br>**Catalog**<br>**Numbers***<br>HLD|**Catalog Numbers**<br>**Terminals**<br>Solder terminals|
|---|---|
|HLD-HH|1⁄4"quick-connect terminals|
**==> picture [510 x 365] intentionally omitted <==**
**----- Start of picture text -----**<br>
-HH 1⁄4" quick-connect terminals Catalog Numbers<br>*Use w/GBA, GLD Fuses. Dimensions - in (mm) Catalog Lamp<br>Numbers Volts Knob Color/Type<br>Dimensions - in (mm) 2.5" Max. (63.5mm Max.)(HLD) (71.4mm)(30.2mm) 2.81" 1.19" HKLHKLHKRHKT*-****X* 90901322----2502502230 Clear/FSClear/OctAmber/OctAmber/Oct<br>0.86" 0.81" HKU** 4-6 Red/Oct<br>(21.8mm) Washer (20.6mm) HKX** 22-33 Amber/FS<br>* Neon lamp — UL Recognized and CSA Certified.<br>Octagonal Sides<br>0.69" ** Incandescent lamp.<br>(17.5mm)<br>Punched Mounting Hole<br>Octagonal Sides 2.75" Max. (HLD-HH)<br>re (69.9mm Max.) .630" [+] 4 .005" OS<br>(16.0mm [+] .13mm)<br>0.505" ± 0.005”<br>(16.0mm ± 0.13mm) .590" [+] .003" 2.81"<br>0.473" ± 0.005” (14.6mm [+] .08mm) Flat-Sides (71.4mm)1.19"<br>(12.0mm ± 0.13mm) (30.2mm)<br>O! Punched Mounting Hole —one a<br>0.81"<br>(20.6mm)<br>Octagonal Sides<br>Punched Mounting Hole<br>.630" [+] .005"<br>(16.0mm [+] .13mm)<br>.573" [+] .003"<br>oa (14.6mm [+] .08mm)<br>Data Sheet: 2120 Data Sheet: 2121 Data Sheet: 2105<br>**----- End of picture text -----**<br>
*Use w/GBA, GLD Fuses.
## **Dimensions - in (mm)**
**Data Sheet: 2120**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**316**
**Fuse Holders and Blocks** a
## **Panel Mounted Fuse Holders for[13] ⁄32" x 1[5] ⁄16" to 1[1] ⁄2" Fuses**
**==> picture [26 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
HPF<br>**----- End of picture text -----**<br>
**==> picture [27 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HPS<br>**----- End of picture text -----**<br>
**==> picture [29 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HPG<br>**----- End of picture text -----**<br>
**==> picture [28 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
HPD<br>**----- End of picture text -----**<br>
**==> picture [66 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
#10 wire max<br>for solder connection<br>**----- End of picture text -----**<br>
## **Specifications**
**Specifications Description:** Standard fuse holders with _**bayonet-type knob**_ for[13] ⁄32" x 1[5] ⁄16" to 1[1] ⁄2" fuses.
**Description:** Standard fuse holders with _**screw-type knob**_ for[13] ⁄32" x 1[5] ⁄16" to 1[1] ⁄2" Fuses.
**Dimensions:** See Dimensions illustration.
**Dimensions:** See Dimensions illustration.
**Agency Information:** CE, UL Recognized, Guide IZLT2, File E14853; CSA Certified, Class 6225-01, File 47235.
**Agency Information:** CE, UL Recognized, Guide IZLT2, File E14853; CSA Certified, Class 6225-01, File 47235.
**Flammability Rating:** UL 94HB. **Terminals:** Combination[1] ⁄4" quick-connect/solder terminals.
**Flammability Rating:** UL 94HB.
**Terminals:** Combination[1] ⁄4" quickconnect/solder terminals.
## **Catalog Numbers**
## **Catalog Numbers**
|**Catalog**<br>**Numbers**<br>HPF<br>HPF-C<br>HPF-L<br>HPF-EE<br>HPF-JJ<br>HPF-FF1|**Amp**<br>**Ratings **<br>302<br>303<br>5<br>15<br>20<br>302|**Volts AC **<br>600<br>6003<br>600<br>600<br>600<br>480|**Fuse Description**<br>11⁄2"(38.1mm)<br>11⁄2"(38.1mm) clear knob.<br>BBS,13⁄32"x 13⁄8"fuses.<br>SC 0-15,13⁄32"x 15⁄16"fuses.<br>SC 20,13⁄32"x 113⁄32"fuses.<br>SC 25 & 30,13⁄32"x 15⁄8"fuses.|
|---|---|---|---|
|HPF-RR|302|600|KTK-R, LP-CC & FNQ-R|
|HPF-WT|302|600|Class CC fuses.<br>Splash-proof knob.13⁄32" x 11⁄2"|
||||(38.1mm)|
|**Catalog**<br>**Symbol**<br>HPS<br>HPS-L<br>HPS-EE*<br>HPS-JJ*<br>HPS-F-EE1|**Amp**<br>**Ratings **<br>30 2 3<br>5<br>15<br>20<br> 15|**Volts AC Fuse Description**<br>600<br>13⁄32"x 11⁄2"<br>600<br>BBS,13⁄32"x 13⁄8"fuses.<br>600<br>SC 0-15,13⁄32"x 15⁄16"fuses.<br>600<br>SC 20,13⁄32"x 113⁄32"fuses.<br>600<br>Sleeve on body, leaded for<br>13⁄32"x 15⁄16"fuses.|**Volts AC Fuse Description**<br>600<br>13⁄32"x 11⁄2"<br>600<br>BBS,13⁄32"x 13⁄8"fuses.<br>600<br>SC 0-15,13⁄32"x 15⁄16"fuses.<br>600<br>SC 20,13⁄32"x 113⁄32"fuses.<br>600<br>Sleeve on body, leaded for<br>13⁄32"x 15⁄16"fuses.|
|---|---|---|---|
|HPS-FF*1|30 2|480|SC 25 & 30,13⁄32"x 15⁄8"fuses.|
|HPS-RR*1|30 2|600|KTK-R, LP-CC, FNQ-R Class<br>CC fuses.|
- *-EE, -JJ, -FF and -RR versions are UL Recognized for applications requiring branch circuit protection. 1 No CSA Certification
- 1 No CSA Certification
- 2 20A max when used with quick-connect terminals. 3 HPF-C ratings for CSA-15A, 250V
- 2 20A max when used with quick-connect terminals. 3 HPS rated at 250V for CSA
## **Dimensions - in (mm)**
## **Dimensions - in (mm)**
**==> picture [336 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
With Fuse<br>2.81" Max.<br>(71.4mm)<br>With Fuse<br>2.81"<br>1.00" 1.31" 1.78" (71.4mm)<br>(25.4mm) (33.3mm) (45.2mm) 0.88"<br>(22.2mm)<br>(28.6mm) 1.125" 0.180" DIA.(4.6mm) 2.69 (22.2mm)(68.3mm)0.88"" Max. (45.2mm)1.78" (Typ.2) 0.250" (6.35 ±± .08mm) 0.003"<br>Without Fuse<br> 0.250" ± .003" 0.180" 0.80"<br> (6.35 ± .08mm) (4.6mm) (20.2mm)<br> (Typ.2) (28.6mm) 1.125" 2.41"<br>(64.3mm)<br>Without Fuse<br>FUESSEUF FUES<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Standard fuse holders with _**bayonet-type knob**_ for[13] ⁄32" x 1[1] ⁄2" fuses.
**Dimensions:** See Dimensions illustrations.
**Agency Information:** CE, UL Recognized, (Guide IZLT2, File E14853).
**Flammability Rating:** UL 94V0 - fuse holder body UL 94HB - Knob.
|**Catalog Numbers**<br>**Catalog**<br>**Amp**|**Catalog Numbers**<br>**Catalog**<br>**Amp**|**Catalog Numbers**<br>**Catalog**<br>**Amp**||
|---|---|---|---|
|**Numbers **|**Ratings**|**Volts AC**|**Fuse Description**|
|HPG*<br>HPG-EE*|301<br> 15|600<br>600|13⁄32"x 11⁄2"fuses<br>SC 0-15,13⁄32"x 15⁄16"fuses.|
|HPD**|301|600|13⁄32"x 11⁄2"fuses|
- 1 20A max when used with quick-connect terminals.
*HPG and HPG-EE has combination[1] ⁄4" quick-connect/solder terminals on both side (load) and rear (line) terminals.
**HPD has combination[1] ⁄4" quick-connect/solder terminal on side (load) terminal only. Rear (line) terminal is[3] ⁄16" shorter than HPG. Rear terminal solder only.
## **Dimensions - in (mm)**
**==> picture [150 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.81"<br>HPG, HPG-EE (71.4mm)<br>0.88"<br>(22.2mm)<br>1.125"<br>(28.6mm)<br>© O t =-<br>HPD<br>**----- End of picture text -----**<br>
**Data Sheet: 2113**
**Data Sheet: 2108**
**Data Sheet: 2114**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**317**
**Fuse Holders and Blocks**
## **Panel Mounted Fuse Holders for[13] ⁄32" x 1[1] ⁄2" Fuses**
## **HPM**
**==> picture [41 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HPC-D<br>**----- End of picture text -----**<br>
**==> picture [34 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
HPS2<br>**----- End of picture text -----**<br>
**==> picture [66 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
#10 wire max<br>for solder connection<br>**----- End of picture text -----**<br>
## **Specifications**
**Description:** Standard fuse holder with _**screw-type knob**_ for[13] ⁄32" x 1[1] ⁄2" fuses.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 600Vac/dc Amps: — 30A[1]
> 1 20A max when used with quick-connect terminals.
**Agency Information:** CE, UL Recognized, Guide IZLT2, File E14853; CSA Certified, Class 6225-01, File 47235.
**Flammability Rating:** UL 94HB.
## **Catalog Numbers**
**Catalog Numbers Description** HPM 1⁄4" quick-connect/solder HPM-D Splash-resistant knob[2]
> 2 HPM-D has 1⁄4" quick-connect/solder terminal on rear (load) terminal only. The side (line) terminal is[1] ⁄4" quickconnect only.
## **Dimensions - in (mm)**
**==> picture [110 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
With Fuse<br>(69.5mm)2.73" =<br>0.94"<br>(23.8mm)<br>—_[ 1.41" ==o .<br>(30.6mm)<br>Ypo, = | I<br>2.594"<br>(65.89mm)<br>Without Fuse<br> 0.250" ± 0.003"<br> (6.35 ± 0.08mm)<br>**----- End of picture text -----**<br>
**Nut Torque:** 30 lb-in. **Replacement Knob:** Catalog Number: BK/9789-Y2 (50 pieces)
## **Specifications**
**Description:** Fuse holder with _**screw-type knob**_ for[13] ⁄32" x 1[1] ⁄2" fuses. Supplied with O-ring and panel gasket. **Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 600Vac/dc Amps: — 30A[1]
> 1 20A max when used with quick-connect terminals.
**Agency Information:** CE, UL Recognized, Guide IZLT2, File E14853. **Flammability Rating:** UL 94HB.
## **Catalog Numbers**
**Catalog Number Description** HPC-D Mount in panels up to[1] ⁄4" thick. Replacement knob - BK/9987SA
## **Dimensions - in (mm)**
**==> picture [148 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
With Fuse<br>2.48"<br>(63.1mm)<br>0.88"<br>(22.2mm)<br>1.775"<br>(45.1mm) :<br>= x KO]<br>Awe 0.180"<br>(4.6mm)<br>1.120"<br>(30.5mm)<br>Mounting Hole Mounting Hole<br>Flange Rear of Panel Flange Front of Panel<br>1.031" [+] 0.003"<br>(26.2mm [+] 0.08mm)<br>;<br>0.187" [+] 0.002"<br>(4.75mm [+] 0.05mm)<br>1.312" [+] 0.003" 1.312" [+] 0.003"<br>(33.3mm [+] 0.08mm) 0.890" [+] 0.003" (33.3mm [+] 0.08mm)<br>t i f (22.6mm - [+] 0.08mm) |<br>**----- End of picture text -----**<br>
**Data Sheet: 2109**
## **Specifications**
**Description:** For fuse size[13] ⁄32" x 1[1] ⁄2", meeting UL 1598 requirement that both poles be removed simultaneously. **Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 600V@30A Amps: — 0-30A[1]
> 1 20A max when used with quick-connect terminals.
**Agency Information:** UL 4248 recognized, (Guide IZLT2, File E14853), CSA certified: (Class 6225-01, File 47235). **Flammability Rating:** UL 94V0. **Terminals:**[1] ⁄4” quick-connect/solder.
## **Catalog Numbers**
## **Catalog**
## **Numbers**
HPS2 Standard 10-in carton BK/HPS2 Bulk 100-in carton
## **Dimensions - in (mm)**
**==> picture [123 x 55] intentionally omitted <==**
**----- Start of picture text -----**<br>
(6.0mm)<br>Panel Mount Hole Dimensions SEPg ESa<br>**----- End of picture text -----**<br>
**Data Sheet: 2140**
**Data Sheet: 2112**
**318** For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**Fuse Holders and Blocks** LLL
## **Fuse Blocks for[1] ⁄4" x 1[1] ⁄4" Fuses**
## **Series 8000**
## **Single-Pole Fuse Blocks**
## **Specifications**
**Description:** Single-pole fuse block for[1] ⁄4" x 1[1] ⁄4" (6.4 x 31.8mm) size fuses.
**Dimensions:** See Dimensions illustrations.
## **Specifications**
" **Description:** Bolt-in and snap-in mounting for[1] ⁄4" x 1[1] ⁄4 fuses.
**Construction:** Blocks are molded flame retarded thermoplastic. Clips are spring-bronze.
## **Ratings:**
Volts: — 300V
Amps: — 25A (See Catalog Numbers table)
**Agency Information:** CE, UL Recognized ; File E14853, Guide IZLT2, CSA Certified Class 6225-01, File 47235. **Anti-Rotation Pin:** Single-pole blocks may be ordered without the anti-rotational pin simply by adding an “X” to the number of poles (Example: BK/S-8000-1X).
**Carton Quantity:** 10; shelf package: 100.
**Bulk Carton:** Single-pole and 2-pole fuse blocks – 1,000; Multiple-pole fuse blocks – 3- to 8-pole: 200; 9- to 12-pole: 50. When ordering bulk quantities, prefix “BK/” to catalog number: (Example: BK/S-8001-1-SNP).
**Catalog Numbers Bolt-in Mounting Basic Catalog Agency Poles Numbers Series Terminal Angle Maximums (Suffix)** S-80018000 Solder 0° UL 25A 1 - 12 S-8002- ~~8000~~ 40° CSA 21A SS--81018102-8100 ~~8100~~ Connect3⁄16" Quick 400°° CSA 13AUL 20A S-82018200 1⁄4" Quick 0° UL 20A 1 - 12 S-82028200 Connect 40° CSA 16A S-8203Side S-83018300 Screw — UL 30A ~~8300~~ CSA 25A **Snap-in Mounting** ~~ea~~ **Catalog Agency Poles Numbers Series Terminal Angle Maximums (Suffix)** S-8001-1-SNP 8000 Solder 0° UL 25A Available S-8002-1-SNP ~~8000~~ 40° CSA 21A Availableonly in SS--81018102--11--SNPSNP 8100 ~~8100~~ Connect3⁄16" Quick 400°° CSA 13AUL 20A polesingleonly insingle S-8201-1-SNP 8200 ~~8200~~ 1⁄4" Quick 0° UL 20A pole S-8203-1-SNP Connect Side CSA 16A
## **Catalog Number Build-A-Code**
**Catalog Code BK/ S-8 0 00 -00** Prefix fo ~~r _y~~ Bulk Packing Series 8000 Product Line Type Terminal “0”-Solder “1”- ‹ ¡§∑ Quick Connect “2” - ⁄ ¢∑ Quick Connect “3” - Screw
**==> picture [64 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal Angle<br>“01” - straight (0,)<br>“02”- 40<br>“03” - side*<br>Number of Poles (1-12)<br>*Available only in single pole<br>**----- End of picture text -----**<br>
**Construction:** Bakelite base width[1] ⁄2" (12.7mm); springbronze, bright tin-lead plate clips.
## **Ratings:**
Volts: — 250V
Amps: — 30A
**4405 - 0° Solder terminals with integral terminal and clip**
## **Dimensions - in (mm)**
**==> picture [133 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.31"<br>(58.7mm)<br>re (17.5mm)0.69" (6.7mm)0.27"<br>1.63"<br>(41.3mm)<br>**----- End of picture text -----**<br>
**4406 - Side solder terminal**
**==> picture [121 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
4574 - Spare fuse block<br>Dimensions - in (mm)<br>1.63"<br>(41.3mm)<br>(17.5mm)0.69" (6.7mm)0.27"<br>**----- End of picture text -----**<br>
## **2499 - Side quick-connect**
**Agency Information:** UL Recognized, Guide IZLT2, File E14853
**Terminals:**[1] ⁄4" (6.4mm); 15A, 250V
## **Dimensions - in (mm)**
**==> picture [129 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.63" 0.75"<br>(41.3mm) (19.1mm)<br>(18.3mm)0.72" (6.7mm)0.27"<br>0.5"<br>(12.7mm)<br>**----- End of picture text -----**<br>
Note: Mounting screw hole diameter is 0.147" (3.7mm). Counterbore diameter, 0.636" (8.0mm). Max Mounting Screw No. 6.
**Data Sheet: 2101**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**319**
**Fuse Holders and Blocks**
## **Fuse Blocks for[1] ⁄4" x 1" Fuses**
## **3828 Series**
## **4520 and 4393**
## **Specifications**
**Description:** Fuse block for[1] ⁄4" x 1" (6.4 x 25.4mm) fuses with solder terminals.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 250V Amps: — 30A
**Mounting:** Mounting screw hole diameter is 0.147" (3.7mm), diameter. Max mounting screw No. 6.
## **Catalog Numbers**
|**Catalog Numbers**|**Poles**|***Base Length- in (mm)**|***Base Length- in (mm)**|
|---|---|---|---|
|3828-1<br>3828-2|1<br>2|1⁄2(12.7)<br>11⁄8 (28.6)||
|3828-3|3|13⁄4 (44.5)||
|3828-4|4|23⁄8 (60.3)||
|3828-5|5|3 (76.2)||
|3828-6|6|35⁄8 (92.1)||
|3828-7|7|41⁄4 (108.0)||
|3828-8|8|47⁄8 (123.8)||
|3828-10|10|61⁄8 (155.6)||
|3828-12|12|73⁄8 (187.3)||
*Small phenolic base, base width 1[3] ⁄8" (34.9mm)
## **Specifications**
**Description:** Single-pole fuse block for[1] ⁄4" x 1" fuses. **Dimensions:** See Dimensions illustrations. **Construction:** Bakelite with[1] ⁄2" (12.7mm) width base. Spring-bronze, bright tin-lead plated clips.
## **Ratings:**
Volts: — 250V Amps: — 30A
**Mounting:** Mounting screw hole diameter is 0.147" (3.7mm), counterbore 0.636" (8.0mm) diameter. Max mounting screw No. 6.
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|
|---|---|
|**Catalog**||
|**Numbers**|**Description**|
|4520|Integral clip and straight solder terminals|
|4393|Spare fuse block|
## **No. 4520 - Integral clip and straight solder terminals**
**Dimensions - in (mm)**
**Dimensions - in (mm)**
**==> picture [411 x 88] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.88"<br>(47.6mm)<br>1.94"<br>(49.2mm)<br>“ F A a ,<br>0.63"<br>(15.9mm) (15.2mm) .598" (4.8mm) .188"<br>0.19" 1.38" 1.38"<br>EE (4.8mm) (34.9mm) Be (34.9mm)<br>**----- End of picture text -----**<br>
## **No. 4393 - Spare fuse block**
**Dimensions - in (mm)**
**==> picture [145 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.38"<br>(34.9mm)<br>0.188"<br>0.598" (4.8mm)<br>(15.2mm)<br>a2<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**320**
**Fuse Holders and Blocks** Ba
## **Blocks for[13] ⁄32" X 1[1] ⁄2" Fuses**
## **3743**
## **3835 Series**
## **4421 and 4515**
## **Specifications**
## **Specifications**
**Description:** Add-on fuse blocks for 13⁄32" X 1 1⁄2" (10.3 X 38.1mm) fuses. Single pole blocks lock into each other and can be added at any time. Each has a single end barrier. **Dimensions:** See Dimensions illustration.
**Description:** Multiple pole fuse blocks for[13] ⁄32" X 1[1] ⁄2" (10.3 X 38.1mm) fuses. **Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 250Vac/dc Amps: — 30A
## **Specifications**
**Description:** Single pole fuse blocks for[13] ⁄32" X 1[1] ⁄2" (10.3 X 38.1mm) fuses. **Dimensions:** See Dimensions illustration.
## **Ratings:**
**Agency Information:** CE
Volts: — 600Vac/dc
## **Catalog Numbers**
Amps: — 30A
**==> picture [457 x 309] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog Base* Width illustration.<br>CE, UL Numbers Poles In (mm)<br>3835-1 1 27⁄32 (21.4) Ratings:<br>38353835--23 23 1 2 [13][25] ⁄⁄1632 (46.0)(70.6) Volts: — 250Vac/dc (or less)<br>3835-4 4 3 [3] ⁄4 (95.2) Amps: — 30A<br>38353835--56 56 4 5 [23][11] ⁄⁄3216 (119.9)(144.5) Agency Information: CE<br>3835-7 7 6 [21] ⁄32 (169.0)<br>3835-8 8 7 [5] ⁄8 (193.7) 2.5"<br>3835-9 9 8 [19] ⁄32 (218.8) (63.5mm)<br>3835-10 10 9 [9] ⁄16 (242.9)<br>3835-12 12 11 [1] ⁄2 (292.1)<br>*Base length: 2 [3] ⁄4" (69.9mm) (22.78mm)0.897" (4.8mm)0.19"<br>0.84" 1.29" Dimensions - in (mm)<br>1.63"<br>0.500" (69.9mm) 2.75" (41.3mm)<br>3 7 4 2 1.125" (25.4mm)1.0" (6.4mm)0.25" 4421—Solder Terminals<br>HE o AaELE<br>Base width [5] ⁄8" (15.9mm)<br>oe<br>2.56" 0.25"<br>Note: Mounting screw hole diameter is a (65.1mm) 2.56"<br>0.148" (3.7mm). Countersink, 0.313"<br>0.323" (7.9mm). Max. mounting screw No. 6. (22.78mm) 0.897" (4.8mm)0.19"<br>(8.2mm)<br>0.25"<br>(28.6mm)1.125"1.125" | (6.4mm) ( EBL<br>0.78"<br>(19.8mm) 0.144" 4515—Screw Terminals<br>1.34"<br>i (34.1mm) Base width [3] ⁄4" (19mm)<br>**----- End of picture text -----**<br>
**Agency Information:** CE, UL Recognized Guide IZLT2, File E14853.
## **3742—End Barrier Only**
**==> picture [129 x 65] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.56" 0.323"<br>(65.1mm) (8.2mm)<br>0.25"<br>(28.6mm)1.125"1.125" (6.4mm)<br>0.78"<br>(19.8mm) 0.144"<br>1.34"<br>i (34.1mm)<br>**----- End of picture text -----**<br>
Note: Mounting screw hole diameter is 0.147" (3.7mm). Countersink, 0.312" (7.9mm). Max. mounting screw No. 6.
## **3723—Block and end barrier " marking strip. Length is 9[3] ⁄8 (23.8cm).**
Note: Mounting screw hole is 0.147" (3.7mm) dia. Counterbore, 0.636" (8mm) dia. Max. mounting screw No. 6.
**Data Sheet: 2104**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**321**
**Fuse Holders and Blocks**
## **Rail Mount Fuse Blocks and Holders**
## **NDNF1-WH**
## **Specifications**
**Description:** Fuse holding rail mount terminal block.
**Circuit Jumper:** JF1, 2 circuits **Fuse Size:**[13] ⁄32" X 1[1] ⁄2"* (KTK, FNQ, PVM). **Poles:** 1
**Wire Range:** AWG #8-22 Cu. **Ratings:**
Volts: — 600V Amps: — 30A
**Mounting Options** : 35mm DIN-Rail, C-rail **Fuse Pullers** : • PF1 (standard)
• neon or incandescent bulb
*LPF1 (lighted neon or incandescent bulb). **Torque Rating** : 18 lb-in **Operating Temperature** : 105°C
## **Catalog Numbers**
**Catalog Number Color** NDNF1-WH White **Fuse Pullers (Optional):** PF1
## **Lighted neon or incandescent lamp:**
**Catalog**
|**Catalog**||
|---|---|
|**Numbers**|**Voltage**|
|LPF1-24|24|
|LPF1-120|120|
|LPF1-120-C|120|
|LPF1-220|220|
|LPF1-440|440|
## **NDNLFD1-WH**
## **Specifications**
**Description:** Rail mount fuse holder.
**Circuit Jumper:** JF1, 2 circuits.
" **Fuse Size:**[1] ⁄4" X 1[1] ⁄4 (Bussmann AGC, MDL or equivalent). **Poles:** 1 **Wire Range:** AWG #8-22 Cu. **Ratings:**
Volts: — 600V Amps: — 30A (NDND1 non-fused) — 15A (NDNFD1, 600V/CSA, fused) — 15A (NDNLFD1*fused, indicating) *WH24 - 24V White, WH-90Vdc-600Vdc, 115Vac-600Vac White **Agency Information:** CE **Mounting Options** : 35mm DIN-Rail, C-rail **Marking Tape** : MT12-1-2 **Torque Rating** : 18 lb-in **Operating Temperature** : 105°C **Agency Information** : CSA File 15364
## **Catalog Numbers**
|**Catalog**||||
|---|---|---|---|
|**Number**||**Color**|**Indicator**|
|NDND1-WH||White|NO|
|NDNFD1-WH||White|NO|
|NDNLFD1-WH||White|90Vdc-600Vdc|
||||115Vac-600Vac|
|NDNLFD1-WH 24|WH 24|White|24V|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**322**
## **Power Distribution & Terminal Blocks**
**==> picture [251 x 182] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Section Contents|Page|
|Selection table for SCCR PDBs & Power|
|terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324|
|Power distribution blocks|
|Series PDBFS enclosed, with high SCCR . . . . . . . . . . . .325|
|Series PDB with high SCCR . . . . . . . . . . . . . . . . . . . . . 326|
|Power terminal blocks|
|Series 163 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327-328|
|Series 11675 2- to 12-Pole quick-connect|. . . . . . . . . . . 329|
|Series 11725 2- to 4-Pole quick-connect|. .|. . . . . . . . . . 329|
|Series 160, 162, 163 & 165|. . . . . . . . . . . . . . . .|. . . . . . 329|
|Series 162, 163 & 165 power stud terminal blocks . . . 330|
|Series 160, 162, 163 & 165 power splicer blocks|. . . .|330|
|Series 14002 Barrier terminal blocks. . . . . . . . .|. . . .|. 331|
|Series 14004 Dead front terminal block . . . . . . . . . . . .331|
**----- End of picture text -----**<br>
Scan this tag to get the latest product information for the Power Distribution Blocks.
**323**
**Power Distribution & Terminal Blocks**
## **Selection Table for SCCR Power Distribution Blocks and Power Terminal Blocks**
## **Short-Circuit Current Rated Power Distribution Blocks**
Bussmann offers three distinctly different styles of shortcircuit current rated power distribution blocks (PDBs) and power terminal blocks (PTBs) to match different application needs. The differences are whether the power distribution blocks are enclosed or not, and whether they are UL 1953 Listed PDBs or UL 1059 Recognized PTBs, which have different minimum spacing requirements. The table on this page can assist in the selection of the right series for your application requirements.
## **Why these are important?**
Control Panels. Marking the SCCR on Industrial Control Panels (NEC[®] 409.110), Industrial Machinery Electrical Panels (NEC[®] 607.3(A)), and HVAC equipment (NEC[®] 440.4(B)) is required by the National Electrical Code. PDBs or PTBs not marked with a SCCR, typically are the weakest link and may limit an assembly to no more than 10kA SCCR. The PDBFS and PDB Series have increased spacing required where used in feeder circuits in equipment listed to UL508A (UL1059 PTBs must be evaluated for proper spacings). Also, for building wiring systems, the PDBFS Series and PDB Series power distribution blocks can be used to meet the new 2013 NEC[®] requirements in section 376.56(B) for PDBs in wireways.
Assembly short-circuit current ratings (SCCRs) are now required in the 2011 NEC[®] and UL 508A Listed Industrial
## **Selection Table**
|**Description**|**Catalog**<br>**Page**|**UL**|**Enclosed **|**High**<br> **SCCR***|**Spacing****<br>**1” Air**<br>**2” Surface**|**Industrial**<br>**Control**<br>**Panels**<br>**UL 508A**<br>**Branch**<br>**Circuit**|**Industrial**<br>**Control**<br>**Panels**<br>**UL 508A**<br>**Feeder**<br>**Circuit**|**HVAC**<br>**UL**<br>**1995**|**Wireways**<br>**NEC®**<br>**376.56(B)**<br>**(Requires**<br>**UL 1953)**|
|---|---|---|---|---|---|---|---|---|---|
|Series PDBFS|325|UL 1953 Listed|Yes†|Yes|Yes|Yes|Yes|Yes|Yes|
|Series PDB|326|UL 1953 Listed|No***|Yes|Yes|Yes|Yes|Yes|Yes<br>w/optional<br>cover|
†IP20 Finger-safe under specific conditions, see datasheet 1149.
- *When protected by proper fuse class with maximum ampere rating specified or less.
- **See **PDB Spacing Requirements for Equipment** table below.
- ***Optional covers are available. Not IP20, but provide a safety benefit.
- ****No, except: Yes, if single pole units installed with proper spacings.
**PDB & PTB Minimum Spacing**
|**UL Standard**<br>~~=~~|**Spacing between**<br>**live parts of**<br>**opposite polarity**<br>~~=~~|**Spacing between**<br>**live parts of**<br>**opposite polarity**<br>~~=~~|**Spacing between**<br>**live parts and**<br>**grounded parts**<br>**or enclosure**<br>**@600V**<br>~~=~~|
|---|---|---|---|
||**Through air**<br>**@600V**<br>~~=~~|**Over surface**<br>**@600V**<br>~~=~~||
|508A Feeder<br>Circuits<br>~~=~~|1˝<br>~~=~~|2˝<br>~~=~~|1˝<br>~~=~~|
|508A Branch<br>Circuits<br>~~=~~|3⁄8˝<br>~~=~~|1⁄2˝<br>~~=~~|1⁄2˝<br>~~=~~|
|1995 HVAC<br>~~=~~|3⁄8˝<br>~~=~~|1⁄2˝<br>~~=~~|1⁄2˝<br>~~=~~|
Series PDB ane
Series PDBFS
**Data Sheet: 1049**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**324**
**Power Distribution & Terminal Blocks**
## **Series PDBFS of Power Distribution Blocks**
## **Feature/Benefits**
- •Enclosed, safer installation; IP20 finger-safe under specific conditions
- High short-circuit current ratings up to 200kA: PDBs do not have to be the weak link in achieving high SCCR for an industrial control panel
- Small footprint saves panel space
- Listed to UL 1953 which has minimum spacing requirements at 600V of at least 1” through air and 2” over surface required for feeders in UL 508A Industrial Control Panels
- For 2D CAD drawings visit www.cooperbussmann.com
## **Agency/Standards**
- UL Listed 1953, Guide QPQS, File E256146
- CSA Certified, Class 6228-01, File 47235
- IEC 60947-7-1
- IEC 60529, IP20 (finger-safe) under specific wiring conditions
## **Electrical**
- 600Vac/dc (UL 1953), 690Vac/dc (IEC)
- IP20 finger-safe under specific conditions
- Short-circuit current ratings up to 200kA, see table
- Ampacities up to 760 amps
- Cu wire range 14 AWG to 500 kcmil or 2.5 to 240 mm[2]
## **Mechanical**
- DIN-Rail or panel mount; PDBFS330 & PDBFS504 panel mount only
- Captive termination screws; screws do not get misplaced
- Wire ready: captive termination screws shipped backed out to save time on conductor installations
- Sliding DIN-Rail latch for easy mounting
- Single pole, gang mountable for multiple pole applications with interlocking dovetail accessory (optional)
- Flammability, UL 94V0
- Tin-plated Al connectors suitable for Cu conductors
- Elongated hole for panel mounting; easier mounting with greater flexibility in matching up with drilled panel holes
- Part 2A1279: Interlocking dovetail pin accessory One pin interlocks two units, two pins to interlock three units
- DIN-Rail end anchors required to prevent damage to block when torquing
## **Series PDBFS**
|**Electrical**<br>~~fy~~<br>~~Pet}oof~~|**Electrical**<br>~~fy~~<br>~~Pet}oof~~|**Terminal Copper Conductor Capability Short-Circuit Current Ratin**<br>~~fy~~<br>~~at~~|**Terminal Copper Conductor Capability Short-Circuit Current Ratin**<br>~~fy~~<br>~~at~~|**Terminal Copper Conductor Capability Short-Circuit Current Ratin**<br>~~fy~~<br>~~at~~|**Short-Circuit Current Rating Data**<br>~~at~~|**Short-Circuit Current Rating Data**<br>~~at~~|**Short-Circuit Current Rating Data**<br>~~at~~|**Short-Circuit Current Rating Data**<br>~~at~~|**Short-Circuit Current Rating Data**<br>~~at~~|**Short-Circuit Current Rating Data**<br>~~at~~|**Short-Circuit Current Rating Data**<br>~~at~~|
|---|---|---|---|---|---|---|---|---|---|---|---|
|||**Line Load**<br>~~fy~~<br>~~t}oof~~|**Line Load**<br>~~fy~~<br>~~t}ooffT~~|**Configuration**<br>~~at~~<br>~~fT~~|**Conductors Max Fuse Class & Amp****<br>~~at~~<br>~~fTLEE~~||**Conductors Max Fuse Class & Amp****<br>~~LEEEL~~||||~~EL~~|
|**Catalog**<br>~~fy~~<br>~~Pe~~|~~fy~~<br>~~t}oof~~|~~fy~~<br>~~t}oof~~|~~fy~~<br>~~t}ooffT~~|~~at~~<br>~~fT~~|~~at~~<br>~~fTLEE~~|~~at~~<br>~~LEE~~|~~LEE~~|~~LEE~~|~~EL~~|~~EL~~|~~EL~~|
|**Number**<br>**(All Single**<br>**Pole)**<br>~~Pe~~|**Amps**<br>~~t}oof~~|**Wire Range**<br>~~t}oof~~|**Wire Range**<br>~~t}ooffT~~|**Openings per Pole**<br>**Line Load**<br>~~fT~~|**Line**<br>**AWG or**<br>**kcmil**<br>~~fTLEE~~|**Load**<br>**AWG or**<br>**kcmil**<br>~~LEE~~|**J**<br>**LPJ**<br>~~LEE~~|**T**<br>**JJS**<br>**JJN**<br>~~LEE~~|**RK1**<br>**LPS-RK**<br>**LPN-RK**<br>~~EL~~|**RK5**<br>**FRS-R**<br>**FRN-R**<br>~~EL~~|**SCCR**<br>~~EL~~|
|PDBFS204<br>~~Pe ~~|175A<br> ~~t}oof~~|2/0 to 8 AWG<br>70 to 10 mm2<br>~~t}oof~~|2/0 to 8 AWG<br>70 to 10 mm2<br>~~t}oof fT~~|~~fT~~<br>:<br>|O||2/0 to 8<br>~~fT LEE~~|2/0 to 8<br>~~LEE~~<br>ee|200<br>~~LEE~~<br>ee|200<br>~~LEE ~~<br>ee|100<br> ~~EL~~<br>ee|60<br>~~EL~~<br>ee|200kA<br>~~EL~~<br>ee|
|PDBFS220<br>~~ee~~|175A<br>~~ee~~|2/0 to 8 AWG<br>70 to 10 mm2<br>~~ee~~|4 to 14 AWG<br>25 to 2.5 mm2<br>~~ee~~|OO<br>|O|<br>~~OO~~|2/0 to 8<br>~~OO~~|4 to 12<br>ee<br>~~ee~~<br>|200<br>ee<br>~~ee~~<br>|200<br>ee<br>~~ee eee ee~~<br>|100<br>ee<br>~~eee ee~~<br>|60<br>ee<br>~~eee ee~~<br>|200kA<br>ee<br>|
|||||||4 to 14<br>ee <br>~~ee~~<br>~~OO~~|175<br>ee<br>~~ee~~<br>|175<br>ee<br>~~ee eee ee~~<br>|100<br>ee<br>~~eee ee~~<br>|30<br>ee<br>~~eee ee~~<br>|100kA<br>ee<br>|
||||||||200<br> ee <br>~~ee~~<br>~~OO~~|200<br> ee <br>~~ee eee ee~~<br>~~OO~~|100<br> ee <br>~~eee ee~~<br>~~OO~~|60<br> ee <br>~~eee ee~~<br>~~OO~~|50kA<br> ee<br>~~OO~~|
|PDBFS303<br>~~ee~~|310A<br>~~ee~~|350kcmil to 6 AWG <br>185 to 16 mm2<br>~~ee~~|350kcmil to 6 AWG<br>185 to 16 mm2<br>~~ee ~~|~~OO~~<br>000<br>|O]|350 to 6<br>~~OO~~|350 to 6 <br>~~ee~~<br>~~OO~~<br>ee|400<br>~~ee~~<br>~~OO~~<br>ee|400<br>~~ee eee ee~~<br>~~OO~~<br>ee|200<br>~~eee ee~~<br>~~OO~~<br>ee|100<br>~~eee ee~~<br>~~OO~~<br>es|200kA<br>~~OO~~|
|PDBFS330<br>~~ee~~<br>>)|380A<br>~~ee~~<br>>)|500kcmil to 6 AWG<br>240 to 16 mm2<br>~~ee~~<br>>)|2 to 14 AWG<br>35 to 2.5 mm2<br>~~ee ~~<br>>)|<br>000<br>|O]<br>coool<br>eds|500 to 6<br><br>|TCE<br>SSS|2 to 6<br>~~ee~~<br><br>ee<br>—_————EE|400<br>~~ee~~<br><br>ee<br>—_————EE|400<br>~~ee eee ee~~<br><br>ee<br>—_————EE|200<br>~~eee ee~~<br><br>ee<br>—_————EE|100<br>~~eee ee~~<br><br>es<br>—_————EE|200kA<br><br>—_————EE|
|||||||2 to 14<br>ee <br>—_————EE<br>TCE<br>SSS|200<br>ee<br>—_————EE<br>a<br>SSS|200<br>ee<br>—_————EE<br>SSS|100<br>ee<br>—_————EE<br>ee<br>SSS|60<br>es<br>—_————EE<br>ee<br>SSS|50kA<br>—_————EE<br>SSS=|
||||||||175<br> ee <br>—_————EE<br>a<br>TCEdT<br>SSS|175<br> ee <br>—_————EE<br>dT<br>SSS|100<br> ee <br>—_————EE<br>ee<br>SSS|30<br> es<br>—_————EE<br>ee<br>SSS|100kA<br>—_————EE<br>SSS=|
|PDBFS377<br>>)|570A<br>>)|300kcmil to 4 AWG<br>150 to 12 mm2<br>>)|4 to 14 AWG<br>25 to 2.5 mm2<br>>)|coool <br>eds|300<br>|TCE<br>SSS|4 to 8<br>—_————EE<br>TCE<br>SSS|600<br>—_————EE<br>a<br>TCEdT<br>SSS|600<br>—_————EE<br>dT<br>SSS|400<br>—_————EE<br>ee <br>SSS|200<br>—_————EE<br> ee<br>SSS|200kA<br>—_————EE<br>SSS=|
||||||300 to 4<br> | TCE<br>SSS|4<br>TCE<br>SSS|400<br>TCEdT<br>SSS|400<br>dT<br>SSS|200<br>SSS|100<br>SSS|100kA<br>SSS=|
|||||||4 to 14<br>TCE<br>SSS|200<br>TCE dT<br>SSS|200<br>dT<br>SSS|100<br>SSS|60<br>SSS|50kA<br>SSS=|
|PDBFS500<br>|620A <br>|350kcmil to 4 AWG <br>185 to 12 mm2<br>|350kcmil to 4 AWG<br>185 to 12 mm2<br>|eds|350 to 4<br>SSS|350 to 4 <br>SSS|600<br>SSS|600<br>SSS|400<br>SSS|200<br>SSS|200kA<br>SSS=|
|PDBFS504<br>Pesta|760A<br>Pesta|500kcmil to 6 AWG <br>240 to 16 mm2<br>Pesta|500kcmil to 6 AWG<br>240 to 16 mm2<br>Pesta|<br>PF|500<br>=<br>PFot|500<br>=<br>otUE|600<br>=<br>UE|800*<br>=<br>|600<br>=<br>|200<br>=<br>|200kA<br>=<br>|
||||||500 to 6<br> =<br>PFot|500 to 6 <br>=<br>otUE|600<br>=<br>UETE|600<br>=<br>TE|400<br>=<br>TE|200<br>=<br>TE|100kA<br>=<br>TE|
** Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30, KTK-R-30) or less are suitable for all SCCRs in this table.
**Data Sheet: 1049**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**325**
**Power Distribution & Terminal Blocks**
## **Series PDB of Power Distribution Blocks**
## **Electrical**
- 600Vac/dc (UL 1953)
- Short-circuit current ratings up to 200kA, see table
- Wire range 14 AWG to 350 kcmil Cu
- Spacing between uninsulated opposite polarities or ground meets UL 1953 which requires at least 1” through air and 2” over surface
- Ratings available with circuit breakers
## **Mechanical**
- Panel mount
## **Feature/Benefits**
- High short-circuit current ratings up to 200kA. These PDBs do not have to be the weak link in achieving high SCCR for an industrial control panel
- Listed to UL 1953 which has minimum spacing requirements at 600V of at least 1” through air and 2” over surface required for feeder in UL 508A Industrial Control Panels
- For 2D CAD drawings visit www.cooperbussmann.com
## **Agency/Standards**
• UL Listed 1953, Guide QPQS, File E256146
- Flammability, UL 94V0
- Tin-plated Al connectors suitable for Cu conductors
## **Optional covers**
- Covers are ordered for each individual pole, i.e., three 1-pole covers for 3-pole block, see table A.
Except PDB321 blocks have one cover for 1-, 2- or 3-pole versions, see table B.
|**Table A**|**Table A**|**Table B**||
|---|---|---|---|
|**Block**<br>PDB2XX-(pole):<br>PDB3XX-(pole):|**Cover**<br>CPB162-1<br>CPDB-1|**Block**<br>PDB321-1<br>PDB321-2|**Cover**<br>CPDB-1<br>CPDB-2|
|||PDB321-3|CPDB-3|
## **Series PDB**
|~~ane~~|~~ane~~|**Terminal Copper Conductor Capability Short-Circuit Current Ratin**<br>~~oO~~<br>~~ane~~<br>~~ee~~|**Terminal Copper Conductor Capability Short-Circuit Current Ratin**<br>~~oO~~<br>~~ane~~<br>~~ee~~|**Terminal Copper Conductor Capability Short-Circuit Current Ratin**<br>~~oO~~<br>~~ane~~<br>~~ee~~|**Short-Circuit Current Rating Data**<br>~~oOS$9oro-~~|**Short-Circuit Current Rating Data**<br>~~oOS$9oro-~~|**Short-Circuit Current Rating Data**<br>~~oOS$9oro-~~|**Short-Circuit Current Rating Data**<br>~~oOS$9oro-~~|**Short-Circuit Current Rating Data**<br>~~oOS$9oro-~~|**Short-Circuit Current Rating Data**<br>~~oOS$9oro-~~|**Short-Circuit Current Rating Data**<br>~~oOS$9oro-~~|
|---|---|---|---|---|---|---|---|---|---|---|---|
|||**Line Load**<br>~~ane~~|**Line Load**<br>~~ee~~|**Configuration**<br>~~oO~~<br>~~ee~~|**Conductors Max Fuse Class & Amp***<br>~~oO~~||**Conductors Max Fuse Class & Amp***<br>~~S$9oro-~~||||~~S$9oro-~~|
|**Catalog**<br>~~ane~~|~~ane~~|~~ane~~|~~ee~~|~~oO~~<br>~~ee~~|~~oO~~|~~oO~~|~~S$9oro-~~|~~S$9oro-~~|~~S$9oro-~~|~~S$9oro-~~|~~S$9oro-~~|
|**Number**<br>**-Pole**<br>~~ane~~|**Amps**<br>~~ane~~|**Wire Range**<br>~~ane~~|**Wire Range**<br>~~ee~~|**Openings per Pole**<br>**Line Load**<br>~~oO~~<br>~~ee~~|**Line**<br>**AWG or**<br>**kcmil**<br>~~oO~~|**Load**<br>**AWG or**<br>**kcmil**<br>~~oO~~|**J**<br>**LPJ**<br>~~S$9oro-~~|**T**<br>**JJS**<br>**JJN**<br>~~S$9oro-~~|**RK1**<br>**LPS-RK**<br>**LPN-RK**<br>~~S$9oro-~~|**RK5**<br>**FRS-R**<br>**FRN-R**<br>~~S$9oro-~~|**SCCR**<br>~~S$9oro-~~|
|PDB204-1<br>PDB204-3<br>~~ane~~|175A<br>~~ane~~|2/0 - 8 AWG<br>~~ane~~|2/0 - 8 AWG<br>~~ee~~|~~oO~~<br>~~ee~~|2/0 - 8<br>~~oO~~|2/0 - 8<br>~~oO ~~|200<br> ~~S$9oro-~~|200<br>~~S$9oro-~~|200<br>~~S$9oro-~~|60<br>~~S$9oro-~~|200kA<br>~~S$9oro-~~|
|PDB220-1<br>PDB220-3|175A<br>~~fo~~|2/0 - 8 AWG<br>~~foff~~|4 - 14 AWG<br>~~ff~~|OO<br>lO|ss<br>~~ofeh~~|2/0 - 8<br>~~Pt~~|4 - 12<br>~~ee~~<br>~~pt~~|200<br>ee<br>~~pt~~|200<br>ee<br>~~pt~~|200†<br>ee<br>~~pt~~|60†<br>ee|200kA<br>ee|
|||||||14<br>~~ee~~ <br>~~pt~~<br>~~PtPp~~|175†<br> ee <br>~~pt~~|175†<br> ee<br>~~pt~~|100†<br>ee <br>~~pt~~|60†<br> ee|100kA<br> ee|
||||||||200†<br>~~pt~~<br>~~i~~<br>~~Pp~~|200†<br>~~pt~~<br>~~Pppp~~|100†<br>~~pt~~<br>~~pp~~|60†<br>~~pp~~|50kA|
|PDB280-1<br>PDB280-3<br>Pt|175A<br>Pt<br>~~fo~~|2/0 - 8 AWG<br>Pt<br>~~foff~~|1/4-20 X 3/4 STUD<br>Pt<br>~~ff~~|~~ofeh~~|2/0 - 8<br>~~Pt~~|Stud<br>~~PtPp~~|200<br>~~Pp~~|200<br>~~Pppp~~|100<br>~~pp~~|60<br>~~pp~~|200kA|
|PDB321-1<br>PDB321-2<br>PDB321-3<br>Pt|175A<br>Pt<br>~~fo~~|2/0 - 8 AWG<br>Pt<br>~~fo ff~~|4 - 14 AWG<br>Pt<br>~~ff ~~|~~ofeh ~~<br>— <br>LO[sss|2/0 - 8<br> ~~Pt~~<br>|4 -12<br>~~Pt Pp~~<br>~~ep~~<br>|400<br>~~Pp~~<br>~~ep~~<br>es|400<br>~~Pp pp~~<br>~~ep~~<br>|200†<br>~~pp~~<br>~~ep~~<br>|100†<br>~~pp~~<br>~~ep~~<br>|200kA<br>~~ep~~<br>|
||||||||400†<br>~~ep~~<br>es|400†<br>~~ep~~<br>|400†<br>~~ep~~<br>|100†<br>~~ep~~<br>|100kA<br>~~ep~~<br>|
|||||||14<br> ~~ep~~<br>~~a~~|175†<br>~~ep~~<br>es~~a~~|175†<br>~~ep~~<br>~~a~~|100†<br>~~ep~~<br>~~a~~|60†<br>~~ep~~<br>~~a~~|100kA<br>~~ep~~<br>~~a~~|
|PDB323-1<br>PDB323-3|310A|300kcmil - 4 AWG|4 - 12 AWG||300 - 4|4 - 8<br>~~a~~<br>ee|400<br>~~a~~|400<br>~~a~~|200†<br>~~a~~|100†<br>~~a~~|200kA<br>~~a~~|
||||||||400†<br>~~a~~<br>ee|400†<br>~~a~~<br>ee|400†<br>~~a~~<br>ee|100†<br>~~a~~<br>ee|100kA<br>~~a~~<br>ee|
|||||||10 - 12<br>ee|175†<br>ee|175†<br>ee|100†<br>ee|60†<br>ee|100kA<br>ee|
|PDB370-1<br>PDB370-3|310A|350kcmil - 4 AWG|4 - 14 AWG|Ole]|350 - 4|4 - 8<br>ee <br>~~Pt~~|400<br> ee <br>~~Pt~~|400<br> ee<br>~~Pt~~|200†<br>ee|100†<br>ee|200kA<br> ee|
|||||||10 - 14<br>~~Pt~~|400†<br>~~Pt~~|400†<br>~~Pt~~|400†|100†|100kA|
||||||||175†<br>~~Pt~~|175†<br>~~Pt~~|100†|60†|100kA|
|PDB371-1<br>PDB371-3|310A|350kcmil - 4 AWG|(6) 2 - 12 AWG<br>(3) 1/0-12|—<br>OE:|350 - 4|1/0 - 6<br>~~es~~<br>PF|400<br>~~es~~<br>es|400<br>~~es~~|200†<br>~~es~~|100†<br>~~es~~|200kA<br>~~es~~|
||||||||400†<br>~~es~~<br>es<br>PF||400†<br>~~es~~<br>|||400†<br>~~es~~<br>|<br>ft|100†<br>~~es~~<br>ft|100kA<br>~~es~~<br>|
|||||||8 - 12<br>PF|175<br>†<br>es<br>PF||175<br>†<br>|||100<br>†<br>|<br>ft|60<br>†<br>ftft|100kA<br>ft|
Ampacities 75ºC per NEC® Table 310.16 and UL508A Table 28.1
- Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30_SP, KTK-R-30) or less are suitable for all these SCCR in this table.
- †Higher SCCR may be available, check data sheet 1049.
**Data Sheet: 1049**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**326**
**Power Distribution & Terminal Blocks** Ba
## **Series 163 Power Terminal Blocks**
## **163 Series**
Replaces Bussmann 164 Series
## **Specifications**
**Description:** Power terminal block. **Dimensions:** See Dimensions illustrations.
**Construction:** Tin-plated aluminum connectors. **Poles:** 1- to 3-Poles, See Catalog Numbers table on the following page.
**Wire Range:** See Catalog Numbers table on the following page.
**Ratings:**
Volts: — 600Vac/dc
Amps: — See catalog Numbers table on the following page. SCCR:— 10kA per UL 508A table SB4.1 (except for select Supplied with (4) #4 thread-cutting products noted in table) screws assembled as shown **Agency Information:** CE, UL Recognized: Guide XCFR2, UL E62622, General Industrial Class per UL1059, CSA Certified: CSA 053787 **Flammability Rating:** UL 94V0 — 4.14" Textured surface for marking ~~—~~ **Dimensions** CPDB-1 (single pole) 2.10" 3-pole CPDB-2 (two pole) 3.72" 5.20" CPDB-3 (three pole) 5.34"
**==> picture [284 x 188] intentionally omitted <==**
**----- Start of picture text -----**<br>
3-pole<br>5.20"<br>2-pole<br>3.58"<br>1-pole<br>1.96"<br>.31"<br>fo<br>4.00" 3.37"<br>0.97" 1.62" 3.32"<br>3.25"<br>Mtg. hole 0.21 x 0.41,<br>c'bore 0.42 x 0.62 x 0.12 deep<br>**----- End of picture text -----**<br>
**(See Following Page for Ratings)**
**Data Sheet: 1049**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**327**
**Power Distribution & Terminal Blocks**
## **Series 163 Power Terminal Blocks**
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**|
|---|---|---|---|---|
|Basic<br>Catalog<br>Wire Size<br>Amps/<br>Numbers<br>(Poles)Lineside<br>(Poles)Loadside<br>Pole<br>Line/Load|||||
|16301*<br>250kcmil-6 AWG Cu Only<br>250kcmil-6 AWG Cu Only<br>255|||||
|16303<br>350kcmil-6 AWG Cu-Al<br>350kcmil-6 AWG Cu-Al<br>310|||||
|16306<br>500kcmil-6 AWG Cu-Al<br>500kcmil-6 AWG Cu-Al<br>380|||||
|16321**<br>2/0-14 AWG CU, 2/0-8Al<br>(6)4-14 AWG Cu, 4-8 AWG Al<br>175|||||
|16323**<br>350kcmil-6 AWG Cu-Al<br>(6)4-14 AWG Cu, 4-12 AWG Al<br>310|||||
|16325<br>(2)2/0-14 AWG Cu, 2/0-8 AWG Al<br>(6)4-14 AWG Cu, 4-8 AWG Al<br>350|||||
|16330<br>500kcmil-6 AWG Cu-Al<br>(6)2-14 AWG Cu, 2-12 AWG Al<br>380|||||
|16332<br>350kcmil-6 AWG Cu-Al<br>(3) 2-14 AWG Cu, 2-8 AWG Al<br>310<br>(2)1/0-14 AWG Cu, 1/0-8 AWG Al|||||
|16335<br>500kcmil-6 AWG Cu-Al<br>(3) 2-14 AWG Cu, 2-8 AWG Al<br>380<br>(2)1/0-14 AWG Cu, 1/0-8 AWG Al|||||
|16370**<br>350kcmil-6 AWG Cu-Al<br>(12)4-14 AWG Cu, 4-12 AWG Al<br>310|||||
|16371**<br>350kcmil-6 AWG Cu-Al<br>(6) 2-14 AWG Cu, 2-8 AWG Al<br>310<br>(3)1/0-14 AWG Cu, 1/0-8 AWG Al|||||
|16372<br>350kcmil-6 AWG Cu-Al<br>(21)10-14 AWG Cu, 10 AWG Al<br>310|||||
|16373<br>350kcmil-6 AWG Cu-Al<br>(14) 10-14 AWG Cu, 10 AWG Al<br>310<br>(3)1/0-14 AWG Cu-Al|||||
|16375<br>600kcmil-2 AWG Cu-Al<br>(12)4-14 AWG Cu, 4-12 AWG Al<br>420|||||
|16376<br>600kcmil-2 AWG Cu-Al<br>(6) 2-14 AWG Cu, 2-8 AWG Al<br>420<br>(3)1/0-14 AWG Cu, 1/0-8 AWG Al|||||
|16377<br>(2)300kcmil-4 AWG Cu-Al<br>(12)4-14 AWG Cu, 4-12 AWG Al<br>570|||||
|16378<br>500kcmil-6 AWG Cu-Al<br>Stud Size(2)1/4-20 x 1<br>380|||||
|16383<br>500kcmil-6 AWG Cu-Al<br>Stud Size(1)3/8-16 x 1<br>380|||||
|16390<br>3⁄8-16 x 11⁄8 Stud Size<br>3⁄8-16 x 11⁄8 Stud Size<br>250|||||
|16394<br>1⁄2-13 x 11⁄16 Stud Size<br>1⁄2-13 x 11⁄16 Stud Size<br>400|||||
|16395<br>3⁄8-16 x 17⁄16 Stud Size<br>(2)1⁄4-20 x9⁄16 Stud Size<br>310|||||
*Copper connectors for use with copper wire only.
**SCCR up to 200kA
## **Ordering Information**
163 Series blocks are available in 1-, 2- or 3-poles. To order: Basic Catalog Number + Number of poles. Examples: 16301-1 = one-pole block
16301-3 = three-pole block
**Data Sheet: 1049**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**328**
**Power Distribution & Terminal Blocks**
## **Power Terminal Blocks**
## **Series 11675**
## **Specifications**
**Description:** Screw connection line side, (3) 0.250" quick-connect load side power terminal block.
**Poles:** 2- to 12-poles.
**Wire Range:** 8 – 14 AWG Cu.
**Ratings:**
Volts: — 250Vac/dc
Amps: — Up to 40A
SCCR:— 10kA per UL 508A table SB4.1
**Agency Information:** CE, Guide XCFR2, UL E62622; CSA 47235.
**Torque Rating:** 9 lb-in max.
## **Catalog Numbers**
|**Catalog**||**Catalog**||
|---|---|---|---|
|**Numbers**|**Poles**|**Numbers**|**Poles**|
|11675-2|2|11675-8|8|
|11675-3|3|11675-9|9|
|11675-4<br>11675-5<br>11675-6<br>11675-7|4<br>5<br>6<br>7|11675-10<br>11675-11<br>11675-12|10<br>11<br>12|
## **Series 11725**
## **Specifications**
**Description:** Screw connection line side, (4) 0.250" quick-connect load side power terminal block.
**Poles:** 2-, 3- or 4-poles. **Wire Range:** 2 – 14 AWG Cu/8 AWG Al.
**Ratings:**
Volts: — 600Vac/dc
Amps: — Up to 70A
SCCR:— 10kA per UL 508A table SB4.1
**Agency Information:** CE, UL Guide XCFR2, E62622; CSA 47235.
**Torque Rating:** 45 lb-in max.
## **Catalog Numbers**
|**Catalog**<br>**Numbers**|**Poles**|
|---|---|
|11725-2|2|
|11725-3|3|
|11725-4|4|
## **Series 160, 162, 163 & 165**
## **Specifications**
**Description:** Power terminal blocks.
**Construction:** Molded black thermoplastic.
**Wire Range:** See Catalog Numbers table.
## **Poles:**
Series 160: 2-, 3- or 4-poles
Series 162, 163 and 165: 1-, 2- or 3-poles
## **Ratings:**
Volts: — 600Vac/dc
Amps: — Up to 1520A
SCCR:— 10kA per UL 508A table SB4.1 (except for select products noted in table)
**Agency Information:** CE, Guide XCFR2, UL E62622 General Industrial Class per UL 1059; CSA Class 6228-01, File 53787.
**Flammability Rating:** UL 94V0.
## **Catalog Numbers**
||**Catalog Numbers**|**Catalog Numbers**||**Connector**||
|---|---|---|---|---|---|
||**Catalog**|**Line**|**Load**|**Material &**|**Agency**|
||**Numbers Connection**|**Numbers Connection**|**Connection**|**Ampacity**|**Information**|
||16021*|2/0-#14Cu, 2/0-#8Al|(6)#4-#14Cu, #4-#8Al|175A|UL/CSA|
||16023*|350kcmil-#6Cu/Al|(6)#4-#14Cu, #4-#12Al|310A|UL/CSA|
||16220**|2/0-#14Cu, 2/0-#8Al|(4)#4-#14Cu, #4-#8Al|175A|UL/CSA|
||16321**<br>16323**|2/0-#14Cu, 2/0-#8Al<br>350kcmil-#6Cu/Al|(6)#4-#14Cu, #4-#8Al<br>(6)#4-#14Cu, #4-#12Al|175A<br>310A|UL/CSA<br>UL/CSA|
|16325<br>(2)2/0-#14Cu, 2/0-#8Al<br>16330<br>500kcmil-#6Cu/Al<br>16332<br>350kcmil-#6Cu/Al<br>16335<br>500kcmil-#6Cu/Al<br>~~—— a,~~|||(6)#4-#14Cu, #4-#8Al<br>(6)#2-#14Cu, #2-#12Al<br>(3)#2-#14Cu, #2-#8Al<br>(2)1/0-#14Cu, 1/0-#8Al<br>(3)#2-#14Cu, #2-#8Al<br>~~aH,~~|350A<br>380A<br>310A<br>380A<br>~~Oawqwr oo~~|UL/CSA<br>UL/CSA<br>UL/CSA<br>UL/CSA<br>~~oo~~|
||16370**<br>16371**|350kcmil-#6Cu/Al<br>350kcmil-#6Cu/Al|(2)1/0-#14Cu, 1/0-#8Al<br>(12)#4-#14Cu, #4-#12Al<br>(6)#2-#14Cu, #2-#8Al|310A<br>310A|UL/CSA<br>UL/CSA|
||16372|350kcmil-#6Cu/Al|(3)1/0-#14Cu, 1/0-#8Al<br>(21)#10-#14Cu, #10Al|310A|UL/CSA|
||16373<br>16375|350kcmil-#6Cu/Al<br>600kcmil-#2Cu/Al|(3)1/0-#14Cu/Al<br>(14)#10-#14Cu, #10Al<br>(12)#4-#14Cu, #4-#12Al|310A<br>420A|UL/CSA<br>UL/CSA|
||16376|600kcmil-#2Cu/Al|(6)#2-#14Cu, #2-#8Al<br>(3)1/0-#14Cu, 1/0-#8Al|420A|UL/CSA|
||16377<br>16400|(2)300kcmil-#4Cu/Al<br>(4)500kcmil-#6Cu/Al|(12)#4-#14Cu, #4-#12Al<br>(22)#2-#14Cu/Al|570A<br>1520A|UL/CSA<br>UL/CSA|
||16528|(2)600kcmil-#2Cu/Al|(4)3/0-#6Cu/Al<br>(4)#4-#14Cu/Al|840A|UL/CSA|
||16530<br>16541|(2)500kcmil-#6Cu/Al<br>(1)500kcmil-#6Cu/Al|(12)#4-#14Cu/Al<br>(21)#6-#14Cu/Al|760A<br>380A|UL/CSA<br>UL/CSA|
*160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165) have mounting holes within barriers. See Data Sheet for dimensional drawings.
**SCCR up to 200kA
## **How To Order**
Catalog Number + # of Poles
Example: 16021 – 3 (complete part number)
## **Optional Covers:**
160 Series: CPB160 - (pole) 162 Series: CPB162 - (pole) 163 Series: CPDB- (pole) 165 Series: CPDB165 (1 for each pole)
**Data Sheets: 1117 (Series 160, 162, 165); 1148 (Series 163)**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**329**
**Power Distribution & Terminal Blocks**
## **Power Terminal Blocks: Stud & Splicer**
## **Series 162, 163 & 165**
## **Specifications**
**Description:** Power stud terminal blocks.
**Construction:** Molded black thermoplastic.
**Poles:** 1-, 2- or 3-poles.
**Wire Range:** See Catalog Numbers table.
## **Ratings:**
Volts: — 600Vac/dc
Amps: — Up to 760A
SCCR:— 10kA per UL 508A table SB4.1 (except where noted)
**Agency Information:** CE, Guide XCFR2, UL E62622
General Industrial Class per UL 1059; CSA Class 6228-01, File 53787.
## **Flammability Rating:**
UL 94V0.
## **Stud Block Catalog Numbers**
|**Stud Block Catalog Numbers**<br>**Catalog**<br>**Numbers**|**Stud Block Catalog Numbers**<br>**Line**<br>**Connection (Poles)**|**Stud Block Catalog Numbers**<br>**Load**<br>**Connection (Poles)**|**Material &**<br>**Ampacity**|**Connector**<br>**Agency**<br>**Information**|**Connector**<br>**Agency**<br>**Information**|
|---|---|---|---|---|---|
|**Connector to Stud**||||||
|16280*|2/0-#14Cu-Al|1⁄4-20 X3⁄4 Stud|Al-175A|UL|—|
|16281|2/0-#14Cu-Al|1⁄4-20 Tapped hole|Al-175A|UL|—|
|16378|500kcmil-#6Cu-Al|(2)1⁄4-20 x 1 Stud|Al-380A|UL|CSA|
|16383|500kcmil-#6Cu-Al|(1)3⁄8-16 x 1 Stud|Al-380A|UL|CSA|
|16582|(2)500kcmil-#6Cu-Al|(2)3⁄8-16 x 15⁄8 Stud|Al-760A|UL|CSA|
|**Stud to Stud**||||||
|16290|1⁄4-20 x3⁄4 Stud|1⁄4-20 x3⁄4 Stud|Cu-175A|UL|—|
|16390|3⁄8-16 x 11⁄8 Stud|3⁄8-16 x 11⁄8 Stud|Cu-250A|UL|CSA|
|16394|1⁄2-13 x 11⁄16 Stud|1⁄2-13 x 11⁄16 Stud|Cu-400A|UL|CSA|
|16395|3⁄8-16 x 17⁄16 Stud|(2)1⁄4-20 x9⁄16 Stud|Cu-310A|UL|CSA|
|16591|3⁄8-16 x 17⁄16 Stud|(2)3⁄8-16 x 17⁄16 Stud|Cu-400A|UL|CSA|
|16593**|1⁄2-13 X 1 Stud|1⁄2-13 X 1 Stud|Cu-600A|UL|CSA|
|Nuts are not supplied with blocks||||||
*SCCR up to 200kA
## **Series 160, 162, 163 & 165**
## **Specifications**
**Description:** Power splicer terminal blocks.
**Construction:** Molded black thermoplastic. **Wire Range:** See Catalog Numbers table. **Poles:** Series 160: 2-, 3- or 4-poles
Series 162, 163 and 165: 1-, 2- or 3-poles
## **Ratings:**
Volts: — 600Vac/dc
Amps: — Up to 760A
SCCR:— 10kA per UL 508A table SB4.1 (except for select products noted in table)
**Agency Information:** CE, Guide XCFR2, UL E62622 General Industrial Class per UL 1059; CSA Class 6228-01, File 53787.
**Flammability Rating:** UL 94V0.
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**||**Connector**||
|---|---|---|---|---|
|**Catalog**|**Line**|**Load**|**Material &**|**Agency**|
|**Numbers Connection**|**Numbers Connection**|**Connection**|**Ampacity**|**Information**|
|16000*|2/0-#8Cu/Al|2/0-#8Cu/Al|Al-175A|UL|
|16003*|250kcmil-#6Cu Only|250kcmil-#6Cu Only|Cu-255A|UL|
|16005*|350kcmil-#6Cu/Al|350kcmil-#6Cu/Al|Al-310A|UL|
|16200|#2-#14Cu, #2-#8Al|#2-#14Cu, #2-#8Al|Al-115A|UL|
|16201|1/0-#14Cu Only|1/0-#14Cu Only|Cu-150A|UL|
|16204**|2/0-#8Cu/Al|2/0-#8Cu/Al|Al-175A|UL|
|16301|250kcmil-#6Cu Only|250kcmil-#6Cu Only|Cu-255A|UL/CSA|
|16303|350kcmil-#6Cu/Al|350kcmil-#6Cu/Al|Al-310A|UL/CSA|
|16306|500kcmil-#6Cu/Al|500kcmil-#6Cu/Al|Al-380A|UL/CSA|
|16500|(2)350kcmil-#4Cu/Al|(2)350kcmil-#4Cu/Al|Al-620A|UL/CSA|
|16504|(2)500kcmil-#6Cu/Al|(2)500kcmil-#6Cu/Al|Al-760A|UL/CSA|
|*160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165)||*160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165)||*160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165)|
|have mounting holes within barriers. See Data Sheet for dimensional drawings.|||||
**SCCR up to 200kA
** 1-Pole not available
## **How To Order**
Catalog Number + # of Poles
Example: 16000 – 3 (complete part number)
## **Optional Covers:**
160 Series: CPB160 - (pole) 162 Series: CPB162 - (pole)
163 Series: CPDB - (pole)
165 Series: CPDB165 (1 for each pole) - new style CPB165 - (pole) - old style
**For Short-circuit current rated stud power distribution blocks, go to the Series PDB and Series 162 & 163 with high SCCR.**
## **How To Order**
Catalog Number + # of Poles Example: 16000 – 3 (complete part number)
## **Optional Covers:**
160 Series: CPB160 - (pole) 162 Series: CPB162 - (pole) 163 Series: CPDB - (pole)
165 Series: CPDB165 (1 for each pole) - new style CPB165 - (pole) - old style
**For Short-circuit current rated and/or finger-safe splicer blocks, go to the Series PDBFS, Series PDB or Series 162 & 163 with high SCCR.**
**Data Sheets: 1117 (Series 160, 162, 165); 1148 (Series 163)**
**Data Sheets: 1117 (Series 162, 165); 1148 (Series 163)**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**330**
**Power Distribution & Terminal Blocks** Bat
## **Power Terminal Blocks: Barrier & Dead Front**
## **Series 14002**
## **Specifications**
**Description:** Barrier terminal block. **Poles:** 2- to 6-poles. **Wire Range:** 2 – 14 AWG Cu/8 AWG Al.
**Ratings:**
Volts: — 600Vac/dc Amps: — 115A SCCR:— 10kA per UL 508A table SB4.1
**Agency Information:** CE, Guide XCFR2, UL E62622; CSA 47235.
**Torque Ratings*:** 2-3, 50 lb-in; 4-6, 45 lb-in; 8, 40 lb-in; 10-14, 35 lb-in.
*Consult factory for torque ratings for CP and Q options.
**Marking:** Marking strip optional, consult factory.
## **Options For Load Side Connector**
CP: Sems pressure plate, rated 60A, 600V Q: Quick-Connect, rated 50A, 600V
To order options, enter letter code in front of Catalog Number: i.e., CP14002-2.
|**Catalog Numbers**||
|---|---|
|**Catalog**<br>**Numbers**<br>**Poles**|**Catalog**<br>**Numbers**<br>**Poles**|
|14002-2<br>2|14002-5<br>5|
|14002-3<br>3|14002-6<br>6|
|14002-4<br>4||
## **Series 14004**
## **Specifications**
**Description:** Dead front terminal block.
**Poles:** 2- to 12-poles.
**Wire Range:** 4 – 14 AWG Cu/ 8 AWG Al.
**Ratings:**
Volts: — 600Vac/dc Amps: — 90A SCCR:— 10kA per UL 508A table SB4.1 **Agency Information:** CE, Guide XCFR2, UL E62622; CSA 47235.
**Marking:** Marking strip optional, consult factory.
## **Catalog Numbers**
|**Catalog Numbers**<br>**Catalog**|**Catalog**|
|---|---|
|**Catalog**<br>**Numbers**<br>**Poles**|**Catalog**<br>**Numbers**<br>**Poles**|
|14004-2<br>2|14004-8<br>8|
|14004-3<br>3|14004-9<br>9|
|14004-4<br>4|14004-10<br>10|
|14004-5<br>5|14004-11<br>11|
|14004-6<br>6|14004-12<br>12|
|14004-7<br>7||
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**331**
>, af X y ry i i DIN-Rail terminal blocks
Ratings up to 200kA SCCR fea ture multiple bridging options for point of use configuration
**332**
## **Connectors**
## **Section Contents**
Scan this tag to get the latest product information for the New Family of Terminal blocks and Accessories.
**==> picture [246 x 546] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Page|
|DIN-Rail Terminal Blocks|
|Feed through blocks (DS series) . . . . . . . . . . . . . . . . . . 334|
|Feed through blocks (DP series)|. . . . . . . . . . . . . . 335-336|
|Mini feed through blocks (DM series)|. . . . . . . . . . . . . . 337|
|Double level blocks (DDP series). . . . . . . . . . . . . . . . . . 338|
|Disconnect blocks (DG series)|. . . . . . . . . . . . . . . . 339-340|
|Fuse holder blocks (F520 series) . . . . . . . . . . . . . . 341-342|
|Internally jumpered blocks (DDNS series) . . . . . . . . . . . 343|
|Test blocks (DTST2 series)|. . . . . . . . . . . . . . . . . . . . . . 343|
|Panel mount blocks. . . . . . . . . . . . . . . . . . . . . . . . . 344-345|
|Short-Circuit Current Ratings (SCCRs)|. . . . . . . . . 346-347|
|Accessories|
|Top screw-on bridges . . . . . . . . . . . . . . . . . . . . . . . . . . . 348|
|End brackets|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349|
|Partition plates|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349|
|Jumper slides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350|
|Top insertion bridges|. . . . . . . . . . . . . . . . . . . . . . . . . . . 350|
|Side insertion bridges . . . . . . . . . . . . . . . . . . . . . . . 351-352|
|Mounting rails and brackets . . . . . . . . . . . . . . . . . . . . . . 353|
|BussScribe Marking System|
|Marking system|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354|
|Marking labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355-357|
|Compact Blocks|
|Feed through blocks (NDN series) . . . . . . . . . . . . . 358-359|
|Feed through blocks (C-Rail series) . . . . . . . . . . . . 360-361|
|Depluggable blocks. . . . . . . . . . . . . . . . . . . . . . . . . 362-363|
|Multi-pole panel mount blocks|. . . . . . . . . . . . . . . . . . . . 364|
|Quick connect blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . 365|
|Double row terminal blocks|
|Series TB100 2- to 36-Pole blocks . . . . . . . . . . . .|366-367|
|Series TB200 & TB200HB 2- to 30-Pole blocks . . 368-369|
|Series TB300 & TB345 2- to 24-Pole blocks . . . .|370-371|
|Marking options and covers for double row|
|series|. . . . . . . . . . . . . . . . . . . . . . . . .|. . . . . . .|372|
|Top & bottom marking strips for terminal|
|blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|373|
|Series TB400 2- to 12-Pole blocks|. . . . . . . . . . .|374|
|Series KU 2- to 12-Pole Panel mount blocks. . . . 375|
|Power feed through terminal blocks|
|Series C7021 1- to 6-Pole block|. . . . . . . . . . . . . . . . . . 376|
|Series C7024 1- to 12-Pole block|. . . . . . . . . . . . . . . . . 377|
**----- End of picture text -----**<br>
## **RED indicates NEW information**
Scan this tag to get access to the Terminal Blocks Cross Reference Search.
**333**
**Connectors**
## **Feed Through Blocks**
**==> picture [490 x 569] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|DS20|DS30|DS50|
|Approval|Approval|Approval|
|Technical Data|UL|IEC|Technical Data|UL|IEC|Technical Data|UL|IEC|
|Rated voltage|600V|1000V|Rated voltage|600V|1000V|Rated voltage|600V|1000V|
|Rated current|20A|24A|Rated current|30A|32A|Rated current|50A|41A|
|Conductor cross section, flexible(AWG/mm2)|22~12 / 0.5~2.5|Conductor cross section, flexible(AWG/mm2)|22~10 / 0.5~4|Conductor cross section, flexible(AWG/mm2)|22~10 / 0.5~4|
|The DS Series features a compact|
|design that saves wiring space|Conductor cross section, flexible(AWG/mm2)|22~12 / 0.5~2.5|Conductor cross section, flexible(AWG/mm2)|22~10 / 0.5~4|Conductor cross section, flexible(AWG/mm2)|20~8 / 0.5~6|
|on the control panel. Accessories|
|include marking labels, partition|Rated impulse withstand voltage|6kV|Rated impulse withstand voltage|6kV|Rated impulse withstand voltage|8kV|
|plates as well as side and top|Torque(N•m)|0.4|Torque(N•m)|0.6|Torque(N•m)|1.2|
|insertion bridges. Designed for|
|Torque(lb-in)|3.5|Torque(lb-in)|5.3|Torque(lb-in)|10.6|
|35mm DIN and 32mm G-Type rails.|
|Screw|M2.5|Screw|M3|Screw|M4|
|IEC60947-7-1 & UL 1059 compliant..|Wire strip length(mm)|9~11|Wire strip length(mm)|9~11|Wire strip length(mm)|12~14|
|WxHxD(mm)|5.1|x|39.6|x|40.5|WxHxD(mm)|6.1|x|39.6|x|40.3|WxHxD(mm)|8|x|45|x|41.7|
|Colors|Cat. No.|Colors|Cat. No.|Colors|Cat. No.|
|e|Grey|DS20-GY|©|Grey|DS30-GY|Grey|DS50-GY|
|e|Blue|DS20-BU|©|Blue|DS30-BU|e|Blue|DS50-BU|
|e|Black|DS20-LK|e|Black|DS30-LK|e|Black|DS50-LK|
|Block|Red|DS20-RD|Red|DS30-RD|Red|DS50-RD|
|(2S|e|e|e|
|e|Orange|DS20-OR|e|Orange|DS30-OR|Orange|DS50-OR|
|e|Yellow|DS20-YW|©|Yellow|DS30-YW|e|Yellow|DS50-YW|
|e|Green|DS20-GN|e|Green|DS30-GN|Green|DS50-GN|
|Accessories|Cat. No.|Accessories|Cat. No.|Accessories|Cat. No.|
|e|Grey|DS20-GY-ND|e|Grey|DS20-GY-ND|e|Grey|DS50-GY-ND|
|e|Blue|DS20-BU-ND|e|Blue|DS20-BU-ND|Blue|DS50-BU-ND|
|e|Black|DS20-LK-ND|e|Black|DS20-LK-ND|e|Black|DS50-LK-ND|
|End cover|sX|e|Red|DS20-RD-ND|e|Red|DS20-RD-ND|e|Red|DS50-RD-ND|
|e|Orange|DS20-OR-ND|©|Orange|DS20-OR-ND|Orange|DS50-OR-ND|
|e|Yellow|DS20-YW-ND|e|Yellow|DS20-YW-ND|e|Yellow|DS50-YW-ND|
|e|Green|DS20-GN-ND|e|Green|DS20-GN-ND|e|Green|DS50-GN-ND|
|Small partition|DKNSPS-001|DKNSPS-001|DKNSPS-002|
|2-pole|DSS2-5N-02P|2-pole|DSS4N-02P|2-pole|DSS6N-02P|
|3-pole|DSS2-5N-03P|3-pole|DSS4N-03P|3-pole|DSS6N-03P|
|Top Insertion bridge|4-pole|DSS2-5N-04P|4-pole|DSS4N-04P|4-pole|DSS6N-04P|
|10-pole|DSS2-5N-10P|10-pole|DSS4N-10P|10-pole|DSS6N-10P|
|2-pole|CSC-2-502PN|2-pole|CSC-402PN|2-pole|CSC-602PN|
|3-pole|CSC-2-503PN|3-pole|CSC-403PN|3-pole|CSC-603PN|
|Side Insertion bridge|4-pole|CSC-2-504PN|4-pole|CSC-404PN|4-pole|CSC-604PN|
|10-pole|CSC-2-510PN|10-pole|CSC-410PN|10-pole|CSC-610PN|
|2-pole|N/A|2-pole|N/A|2-pole|N/A|
|Top Screw-on bridge|3-pole|N/A|3-pole|N/A|3-pole|N/A|
|4-pole|N/A|4-pole|N/A|4-pole|N/A|
|10-pole|N/A|10-pole|N/A|10-pole|N/A|
|Marking label|||1|2|3|4|5|6|7|TM26CB|TM27CB|TM28CB|
|(an)|DRL32MMG|DRL32MMG|DRL32MMG|
|Mounting Rail|LS|DRL35MMHI|DRL35MMHI|DRL35MMHI|
|DRL35MMLO|DRL35MMLO|DRL35MMLO|
|Tool|
**----- End of picture text -----**<br>
## DS Series
The DS Series features a compact design that saves wiring space on the control panel. Accessories include marking labels, partition plates as well as side and top insertion bridges. Designed for 35mm DIN and 32mm G-Type rails.
IEC60947-7-1 & UL 1059 compliant..
For more information, visit www.cooperbussmann.com/DatasheetsEle
**334**
**Connectors**
## **Feed Through Blocks**
**==> picture [490 x 578] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|DP25|DP35|DP45|
|Approval|Approval|Approval|
|Technical Data|UL|IEC|Technical Data|UL|IEC|Technical Data|UL|IEC|
|Rated voltage|600V|630V|Rated voltage|600V|630V|Rated voltage|600V|500V|
|Rated current|25A|24A|Rated current|35A|32A|Rated current|45A|41A|
|Conductor cross section, flexible(AWG/mm2)|22~12 / 0.5~2.5|Conductor cross section, flexible(AWG/mm2)|22~10 / 0.5~4|Conductor cross section, flexible(AWG/mm2)|20~8 / 0.5~6|
|The DP Series features a generous|
|design allowing for more wiring|Conductor cross section, flexible(AWG/mm2)|22~12 / 0.5~2.5|Conductor cross section, flexible(AWG/mm2)|22~10 / 0.5~4|Conductor cross section, flexible(AWG/mm2)|20~8 / 0.5~6|
|space and access. Additionally, this|Rated impulse|8kV|Rated impulse|8kV|Rated impulse|8kV|
|series features a larger wire contact|withstand voltage|withstand voltage|withstand voltage|
|area and larger conducting elements.|Torque(N•m)|0.8|Torque(N•m)|0.8|Torque(N•m)|1.8|
|Accessories include marking labels,|
|Torque(lb-in)|7.1|Torque(lb-in)|7.1|Torque(lb-in)|15.9|
|partition plates, side insertion bridge|
|and top screw-on bridge for|Screw|M3|Screw|M3|Screw|M4|
|improved reliability. Comes with|Wire strip length(mm)|10~12|Wire strip length(mm)|10~12|Wire strip length(mm)|12~14|
|matching shaped grounding blocks.|WxHxD(mm)|5.1|x|47.6|x|58.9|WxHxD(mm)|6.1|x|47.6|x|58.9|WxHxD(mm)|8|x|47.6|x|58.9|
|Designed for 35mm DIN and 32mm|Colors|Cat. No.|Colors|Cat. No.|Colors|Cat. No.|
|e@|Grey|DP25-GY|e|Grey|DP35-GY|e@|Grey|DP45-GY|
|IEC60947-7 and UL1059 compliant.|e|Blue|DP25-BU|°|Blue|DP35-BU|Blue|DP45-BU|
|e|Black|DP25-LK|e|Black|DP35-LK|e|Black|DP45-LK|
|e|Red|DP25-RD|e|Red|DP35-RD|e|Red|DP45-RD|
|Block|(|)|°¢|Orange|DP25-OR|e|Orange|DP35-OR|e|Orange|DP45-OR|
|e|Yellow|DP25-YW|e|Yellow|DP35-YW|Yellow|DP45-YW|
|e|Green|DP25-GN|e|Green|DP35-GN|e|Green|DP45-GN|
|Accessories|Cat. No.|Accessories|Cat. No.|Accessories|Cat. No.|
|i, ee,|
|e@|Grey|DP25-GY-ND|e|Grey|DP25-GY-ND|e|Grey|DP25-GY-ND|
|e|Blue|DP25-BU-ND|e|Blue|DP25-BU-ND|Blue|DP25-BU-ND|
|e|Black|DP25-LK-ND|e|Black|DP25-LK-ND|e|Black|DP25-LK-ND|
|End cover|fr|e|Red|DP25-RD-ND|e|Red|DP25-RD-ND|e|Red|DP25-RD-ND|
|e|Orange|DP25-OR-ND|e|Orange|DP25-OR-ND|Orange|DP25-OR-ND|
|e|Yellow|DP25-YW-ND|e|Yellow|DP25-YW-ND|e|Yellow|DP25-YW-ND|
|e|Green|DP25-GN-ND|e|Green|DP25-GN-ND|e|Green|DP25-GN-ND|
|Partition|‘a|DKSPS-001|DKSPS-001|DKSPS-001|
|Small partition|4|DKSPS-002|DKSPS-002|DKSPS-002|
|2-pole|N/A|2-pole|N/A|2-pole|N/A|
|3-pole|N/A|3-pole|N/A|3-pole|N/A|
|Top Insertion bridge|i|4-pole|N/A|4-pole|N/A|4-pole|N/A|
|10-pole|N/A|10-pole|N/A|10-pole|N/A|
|2-pole|CSC-2-502P|2-pole|CSC-402P|2-pole|CSC-602P|
|Side Insertion bridge|Hi|3-pole4-pole|CSC-2-503PCSC-2-504P|3-pole4-pole|CSC-303PCSC-404P|3-pole4-pole|CSC-603PCSC-604P|
|10-pole|CSC-2-510P|10-pole|CSC-410P|10-pole|CSC-610P|
|2-pole|DS2-5-02P|2-pole|DS4-02P|2-pole|DS6-02P|
|Top Screw-on bridge|3-pole|DS2-5-03P|3-pole|DS4-03P|3-pole|DS6-03P|
|be|4-pole|DS2-5-04P|4-pole|DS4-04P|4-pole|DS6-04P|
|10-pole|DS2-5-10P|10-pole|DS4-10P|10-pole|DS6-10P|
|Marking label|CO|1|2|3|4|5|6|7|TM26CB|TM27CB|TM28CB|
|on)|DRL32MMG|DRL32MMG|DRL32MMG|
|Mounting Rail|LS|DRL35MMHI|DRL35MMHI|DRL35MMHI|
|DRL35MMLO|DRL35MMLO|DRL35MMLO|
|Tool|Cc>——|©|a|0.4 x 2.5mm|0.5 x 3mm|0.8 x 4mm|
**----- End of picture text -----**<br>
## DP Series
The DP Series features a generous design allowing for more wiring space and access. Additionally, this series features a larger wire contact area and larger conducting elements. Accessories include marking labels, partition plates, side insertion bridge and top screw-on bridge for improved reliability. Comes with matching shaped grounding blocks. Designed for 35mm DIN and 32mm G-Type rails.
IEC60947-7 and UL1059 compliant.
For more information, visit www.cooperbussmann.com/DatasheetsEle
**335**
**Connectors**
## **Feed Through Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**336**
**Connectors**
## **Mini Feed Through Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**337**
**Connectors**
## **Double Level Blocks**
## **Disconnect Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**338**
**Connectors**
## **Grounding Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**339**
**Connectors**
## **Grounding Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**340**
**Connectors**
## **Fuse Holder Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**341**
**Connectors**
## **Fuse Holder Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**342**
**Connectors**
## **Internally Jumpered Blocks**
**==> picture [30 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
DDNS10<br>**----- End of picture text -----**<br>
## DDNS Series
|DDNS Series|||||**DDNS10**|**DDNS10**|
|---|---|---|---|---|---|---|
|The DDNS10 is an internally|||||**Approval**||
|jumpered terminal block. Internally|jumpered terminal block. Internally||||**Technical Data**|UL<br>IEC|
|jumpered double-level terminal<br>blocks provide high-density power|blocks provide high-density power||||Rated voltage<br>Rated current|300V<br>630V<br>10A<br>17.5A|
|distribution in 3-in/1-out or 2-in/2-out|||||||
|or 1-in/3-out options with a single<br>block. Add top and side insertion|||||Conductor cross-<br>section, solid<br>(AWG/mm<br>2)|22~14 / 0.5~1.5|
|bridges to achieve any connection<br>topology. IEC60947-7 and UL1059<br>compliant.|||||Conductor cross-<br>section, flexible<br>(AWG/mm<br>2)<br>Rated impulse<br>withstand voltage<br>Torque(N•m)<br>Torque(lb-in)<br>Screw<br>Wire strip length(mm)<br>WxHxD(mm)|22~14 / 0.5~1.5<br>8kV<br>0.4<br>3.5<br>M2.5<br>6~7<br>5.1 x 46.8 x 58.9|
|Block|||||**Colors**<br> Grey<br>**Accessories**<br>e|**Cat. No.**<br>DDNS10-GY<br>**Cat. No.**|
|End cover<br>P~~R~~||||Grey<br>DDNS10-GY-ND<br> 8<br>~~Oe~~|||
|Partition|||||||
|Small partition|||||2-pole<br>N/A<br>~~a~~||
||||||3-pole|N/A|
|Top Insertion bridge|||||4-pole|N/A|
||||||10-pole|N/A|
||||||2-pole<br>3-pole|CSC-2-502P<br>CSC-2-503P|
|Side Insertion bridge|||||4-pole|CSC-2-504P|
||||||10-pole|CSC-2-510P|
|Top Screw-on bridge<br>te|||||2-pole<br>3-pole<br>4-pole<br>10-pole|DS2-5-02P<br>DS2-5-03P<br>DS2-5-04P<br>DS2-5-10P|
|Marking label<br>1<br>2<br>3<br>4<br>5<br>6<br>7<br>LO||||a||TM26CB|
|Mounting Rail<br>a)<br>WW||||||DRL32MMG<br>DRL35MMHI<br>DRL35MMLO<br>es|
|Tool||||||0.4 x 2.5mm|
The DDNS10 is an internally jumpered terminal block. Internally jumpered double-level terminal blocks provide high-density power distribution in 3-in/1-out or 2-in/2-out or 1-in/3-out options with a single block. Add top and side insertion bridges to achieve any connection topology. IEC60947-7 and UL1059 compliant.
## **Test Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**343**
**Connectors**
## **Panel Mount Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**344**
**Connectors**
## **Panel Mount Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**345**
**Connectors**
## **Short-Circuit Current Ratings (SCCRs)**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**346**
**Connectors** a
## **Short-Circuit Current Ratings (SCCRs)**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**347**
**Connectors**
## **Accessories**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**348**
**Connectors**
## **Accessories**
## End Brackets
**==> picture [441 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
BRKT-ND BRKT-NDSCRW BRKT-NDSCRW2 BRKT-NDSCRW3<br>a ny<br># Pei = [a] =a Fh : ;<br>Use with DRL35MMHI Use with DRL35MMHI Use with DRL35MMHI Use with DRL35MMHI<br>DRL35MMLO DRL35MMLO DRL35MMLO DRL35MMLO<br>Torque(N•m) N/A Torque(N•m) 0.5 Torque(N•m) 0.78 Torque(N•m) 1.8<br>Torque(lb-in) N/A Torque(lb-in) 4.4 Torque(lb-in) 6.9 Torque(lb-in) 15.9<br>Screw N/A Screw M3 Screw M3 Screw M4<br>Dimensions - mm Dimensions - mm Dimensions - mm Dimensions - mm<br>**----- End of picture text -----**<br>
## Partition Plates
**==> picture [409 x 266] intentionally omitted <==**
**----- Start of picture text -----**<br>
DKSPS-001 DKSPS-002 DKSPS-006<br>Use with DP25 DP35 Use with DP25 DP35 Use with DTST2<br>DP45 DP60 DP45 DP60<br>DIS10<br>DKNSPS-001 DKNSPS-002 DKNSPS-003 DKNSPS-004<br>Use with DS20 DS30 Use with DS50 Use with DP100 Use with DP150<br>**----- End of picture text -----**<br>
For more information, visit www.cooperbussmann.com/DatasheetsEle
**349**
**Connectors**
## **Accessories**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**350**
**Connectors**
## **Accessories**
## Side Insertion Bridges
**==> picture [425 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
CSC-2-5XXP CSC-4XXP CSC-6XXP CSC-10XXP<br>.<br>— i} ——z a el El<br>Use with DP25 Use with DP35 Use with DTST2 DP45 Use with DP60<br>DIS10 P20S DDP30<br>DDNS10<br>Poles (XX) 02, 03, 04, 10 Poles (XX) 02, 03, 04, 10 Poles (XX) 02, 03, 04, 10 Poles (XX) 02, 03, 04, 10<br>**----- End of picture text -----**<br>
## **Dimensions - mm**
**Dimensions - mm Dimensions - mm Dimensions - mm**
**==> picture [423 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
CSC-16XXP CSC-35XXP CSC-95XXP CSC-2-5XXPN<br>naa rt<br>—e SSSa —— *<br>P<br>% = ”<br>Use with DP100 Use with DP150 Use with DP230 Use with DS20<br>Poles (XX) 02, 03, 04, 10 Poles (XX) 02, 03, 04, 10 Poles (XX) 02, 03, 04, 10 Poles (XX) 02, 03, 04, 10<br>**----- End of picture text -----**<br>
## **Dimensions - mm Dimensions - mm Dimensions - mm Dimensions - mm**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**351**
**Connectors**
## **Accessories**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**352**
**Connectors**
## **Accessories**
**==> picture [170 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mounting Rails and Brackets<br>**----- End of picture text -----**<br>
**==> picture [435 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
DRL15MM* DRL32MMG* DRL35MMLO* DRL35MMHI*<br>(15mm DIN-Rail) (32mm G-Type) (35mm DIN-Rail - Low Profile) (35mm DIN-Rail - High Profile)<br>/ fi/ a<br>NFTA Series** NRA Series** BRKT-ANGL BRKT-FLT<br>(C-Rail) (C-Rail) (Angle Bracket) (Flat Bracket)<br>**----- End of picture text -----**<br>
*Available in 1 meter lengths only.
- **Cut to length. Consult Bussmann for details.
For more information, visit www.cooperbussmann.com/DatasheetsEle
**353**
**Connectors**
## **BussScribe Marking System**
**DPLT-001SET DPLT-SPLT PLOTTER PENS PLOTTER SET SUPPORT PLATE DPLT-PEN** (Tip 0.25mm) **DPLT-PEN2** (Tip 0.35mm) j ~~4~~ **Description Description** • Pen is installed manually Support plate adjustable to accommodate various Disposable black ink cartridge pen. • USB interface to PC sizes of marking labels. The support plate is Single pen per pack.
## **Description**
Support plate adjustable to accommodate various sizes of marking labels. The support plate is universal and suitable for TM2xCB marking label series. Each plotter set includes one support plate, additional plates are available separately.
- Pen is installed manually
- USB interface to PC
- 110-240Vac power supply
- WINDOWS[®] Operation System
System Kit Includes:
- Plotter Pens
- Support Plate
- Software
- Plotter
- Power Supplies
- USB Cable
## Marking Label Selection Chart
|**Part Number**<br>**TM20CB**|**Length (mm)**<br>5.8|**Width (mm)**<br>5.1|**Line x Row**<br>20 x 10|**Number of Tags**<br>200|**Applicable Block Part Numbers**<br>F20T0P,<br>DM20,<br>P20S, P25G, 2P25G|
|---|---|---|---|---|---|
|**TM21CB**|5.8|6.1|20 x 10|200|DDP30,<br>DM30,<br>P30S|
|**TM22CB**|5.8|8.0|20 x 8|160|DM50,<br>P65S|
|**TM26CB**|12|5.1|12 x 12|144|DS20,<br>DP25,<br>DG25,<br>DDNS10,<br>DIS10|
|**TM27CB**|12|6.1|12 x 10|120|DS30,<br>DP35,<br>DG35|
|**TM28CB**|12|8.0|12 x 7|84|DS50,<br>DP45, DP60, DP100, DP150, DP230,<br>DG60, DG100, DG150, DG230,<br>F520ST, F520STLED, F520DDST,<br>DTST2|
For more information, visit www.cooperbussmann.com/DatasheetsEle
**354**
**Connectors Marking Label Ordering Method (typical)**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**355**
**Connectors**
## **Marking Label Ordering Method (typical)**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**356**
**Connectors**
## **Marking Label Ordering Method (typical)**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**357**
**Connectors**
## **NDN Series Feed Through Blocks**
**==> picture [447 x 436] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|NDNV4|NDN3|NDN63|
|Approval|Approval|Approval|
|Technical Data|Technical Data|Technical Data|
|Rated voltage|600V|Rated voltage|600V|Rated voltage|600V|
|Rated Current|30A|Rated Current|30A|Rated Current|65A|
|Center spacing, in (mm)|0.25 / 6.35|Center spacing, in (mm)|0.3 / 7.62|Center spacing, in (mm)|0.375 / 9.52|
|Conductor cross-|Conductor cross-|Conductor cross-|
|section, flexible|22~10 / 0.5~6|section, flexible|22~10 / 0.5~6|section, flexible|18~6 / 1~16|
|(AWG/mm2)|(AWG/mm2)|(AWG/mm2)|
|Number of Poles|4|Number of Poles|3|Number of Poles|3|
|Circuits per foot|48|Circuits per foot|38|Circuits per foot|30|
|Torque(N•m)|2|Torque(N•m)|2|Torque(N•m)|4|
|Torque(lb-in)|18|Torque(lb-in)|18|Torque(lb-in)|35|
|Screw|#6-32|Screw|#6-32|Screw|#10-32|
|WxHxD(mm)|25.4|x|34|x|42.4|WxHxD(mm)|23.9 x 33.3 x 42.4|WxHxD(mm)|29.7 x 36.8 x 42.4|
|Colors|Cat. No.|Colors|Cat. No.|Colors|Cat. No.|
|OO|White (Standard)|NDNV4-WH|White (Standard)|NDN3-WH|White (Standard)|NDN63-WH|
|Black|NDNV4-BK|Black|NDN3-BK|Black|NDN63-BK|
|Block|Yellow|NDNV4-YE|Blue|NDN3-BL|Yellow|NDN63-YE|
|a|ee|
|a|Yellow|NDN3-YE|
|Red|NDN3-RE|
|Accessories|Cat. No.|Accessories|Cat. No.|Accessories|Cat. No.|
|Jumper|4 circuits|JN4|2 circuits|JNDN3|2 circuits|JN3|
|Marking Tape|MTC6|MT12-1-2|MT12-1-2|
|35mm DIN-Rail|DRL35MML0|35mm DIN-Rail|DRL35MML0|35mm DIN-Rail|DRL35MML0|
|DRL35MMHI|DRL35MMHI|DRL35MMHI|
|Mounting|C-Rail|NFTA Series|C-Rail|NFTA Series|C-Rail|NFTA Series|
|C-Rail (low profile)|NRA Series|C-Rail (low profile)|NRA Series|C-Rail (low profile)|NRA Series|
|Modular Option|N/A|N/A|N/A|
|Dimensions - in (mm)|Dimensions - in (mm)|Dimensions - in (mm)|
|(25.40)1.00|MarkingTape|
|1.67|c|1.47|1.23|s,|Pa|
|(42.41)|(37.33)|(31.24)|1.47|1.50|
|(37.33)|(38.10)|
|||4+|P|a|te|r|a|TI|1.67|LA|BI|1.67|
|1.34|(42.41)|(42.41)|
|(34.04)|
|a|Bee|e|e|
|“Zz|a|a|
|Pale|0.94|1.31|1|.17|1.45|
|(23.87)|(33.27)|(29.71)|(36.83)|
**----- End of picture text -----**<br>
## NDN Series
The NDN Series features a compact line of rail-mounted terminal blocks suitable for both 35mm DIN-Rail or C-Rail applications. Products easily snap onto the mounting rail for a quick, simple, low-cost solution. Available accessories include jumpers and marking tape.
UL E62622 CSA File 15364
CSA File 47235 (NDN1, NDN111)
For more information, visit www.cooperbussmann.com/DatasheetsEle
**358**
**Connectors** I
## **NDN Series Feed Through Blocks**
**==> picture [230 x 431] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|NDN1|NDN111|
|Approval|Approval|
|Technical Data|Technical Data|
|Rated voltage|600V|Rated voltage|600V|
|Rated Current|90A|Rated Current|90A|
|Center spacing in (mm)|0.635 / 16.31|Center spacing in (mm)|0.635 / 16.31|
|Conductor cross-|Conductor cross-|
|section, flexible|18~2 / 1~35|section, flexible|18~2 / 1~35|
|(AWG/mm2)|(AWG/mm2)|
|Number of Poles|1|Number of Poles|3|
|Circuits per foot|18|Circuits per foot|18|
|Torque(N•m)|3.6|Torque(N•m)|3.6|
|Torque(lb-in)|32|Torque(lb-in)|32|
|Screw|1/4-28|Screw|1/4-28|
|WxHxD(mm)|15 x 30.3 x 43.5|WxHxD(mm)|47.5 x 36.6 x 43.5|
|Colors|Cat. No.|Colors|Cat. No.|
|White (Standard)|NDN1-WH|White (Standard)|NDN111-WH|
|Black|NDN111-BK|
|Blue|NDN111-BL|
|Yellow|NDN111-YE|
|Red|NDN111-RE|
|Accessories|Cat. No.|Accessories|Cat. No.|
|2 circuits|JN1|
|MT12-1-2|MT12-1-2|
|35mm DIN-Rail|DRL35MML0|35mm DIN-Rail|DRL35MML0|
|DRL35MMHI|DRL35MMHI|
|C-Rail|NFTA Series|C-Rail|NFTA Series|
|Co|C-Rail (low profile)|NDN1A-WH NRA Series|C-Rail (low profile)NDN111A-WH, NDN111A-BK, NDN111A-YENRA Series|
|Dimensions - in (mm)|Dimensions - in (mm)|
|Mtg. holes|
|0.18 (4.57) dia.|
|0.28 (7.11) c'bores|
|1.46|
|(37.13)|
|1.71|
|(43.48)|
|1.71|1.32|
|(43.48)|(33.68)|
|Dovetail|0.62|
|Option|(15.75)|
|1.87|
|(47.50)|
|DovetailOption|(14.99)0.59|(36.31)1.43|n|i|n|)|(36.57)1.44|||
**----- End of picture text -----**<br>
For more information, visit www.cooperbussmann.com/DatasheetsEle
**359**
**Connectors**
## **C-Rail Feed Through Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**360**
**Connectors**
## **C-Rail Feed Through Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**361**
**Connectors**
## **Depluggable Blocks**
**==> picture [456 x 472] intentionally omitted <==**
**----- Start of picture text -----**<br>
15188 15288 PLU3<br>Approval Approval Approval<br>Technical Data Technical Data Technical Data<br>Rated voltage 600V Rated voltage 600V Rated voltage 600V<br>Rated Current 30A Rated Current 65A Rated Current 40A<br>Center spacing in (mm) 0.375 / 9.52 Center spacing in (mm) 0.54 / 13.7 Center spacing in (mm) 0.39 / 9.91<br>Conductor cross- Conductor cross- Conductor cross-<br>section, flexible 16~12 / 1.5~4 section, flexible 16~6 / 1.5~16 section, flexible 22~8 / 0.5~10<br>(AWG/mm2) (AWG/mm2) (AWG/mm2)<br>Number of Poles 3 or 4 Number of Poles 3 Number of Poles 3<br>Circuits per foot 32 Circuits per foot 22 Circuits per foot 28<br>Torque(N•m) 1.4 Torque(N•m) 2.3 Torque(N•m) 2<br>Torque(lb-in) 12 Torque(lb-in) 20 Torque(lb-in) 18<br>Screw #6-32 Screw #8-32 Screw #8-32<br>WxHxD(mm) WxHxD(mm) WxHxD(mm)<br>3-Pole 30.2 x 49.3 x 47.8 43.2 x 49.3 x 47.9 31.8 x 47.0 x 45.6<br>4-Pole 39.2 x 49.3 x 47.8 N/A N/A<br>Colors Cat. No. Colors Cat. No. Colors Cat. No.<br>= White (Standard) 15188-3 White (Standard) 15288 White (Standard) PLU3-WH<br>White (Standard) 15188-4 Black PLU3-BK<br>Block C N Yellow PLU3-YE<br>Accessories Cat. No. Accessories Cat. No. Accessories Cat. No.<br>eses ee<br>Jumper 2 circuits 15188J-2-J 2 circuits JN3<br>MT12-1-2<br>Marking Tape<br>35mm DIN-Rail DRL35MMLO 35mm DIN-Rail DRL35MMLO C-Rail (AL) NFTA Series<br>DRL35MMHI DRL35MMHI C-Rail (low profile) NRA Series<br>Mounting<br>Reverse Wiring 15188-_R Reverse Wiring 15288-R<br>Locking 15188-_S Screw Together 15288-ST<br>Configurable Option Reverse; Locking 15188-_RS Locking 15288-S<br>Options offered for both pole lengths Options may be combined<br>Dimensions - in (mm) Dimensions - in (mm) Dimensions - in (mm)<br>In-Line Wiring Direction 3 Pole = 1.19 (30.22)4 Pole = 1.56 (39.62) In-Line Wiring Direction (13.7) 0.54 for ST option (43.2) (58.4) 1.70 2.30<br>S E oe asl 1.25<br>(31.75)<br>(49.27)1.94 (49.27) 1.94<br>0.59 1.79<br>(14.98) (45.64)<br>Reverse Wiring Direction 3 Pole = 1.19 (30.22) 4 Pole = 1.56 (39.62) (9.52) 0.375 (5.58) 0.22 Reverse Wiring Direction (43.2) 1.70 (31.75) 1.25 (31.75) 1.25 (46.99) 1.85<br>(49.27) 1.94 (49.27)1.94<br>**----- End of picture text -----**<br>
## Depluggable Blocks
Depluggable terminal blocks are available for both 35mm DIN-Rail and C-Rail applications. These blocks provide a simple depluggable* option for panel wiring applications with the convenience of quick, easy, snap-on installation. Product accessories, such as jumpers and marking tape, are available for most products.
UL E62622
CSA File 15364
CSA File 47235 (15188 Series)
*Not for use as a load break disconnect.
For more information, visit www.cooperbussmann.com/DatasheetsEle
**362**
**Connectors** a
## **Depluggable Blocks**
|**PLU1**<br>**Approval**|**PLU1**<br>**Approval**|||**PSU1**<br>**Approval**|**PSU1**<br>**Approval**||
|---|---|---|---|---|---|---|
|**Technical Data**<br>Rated voltage<br>Rated Current<br>Center spacing in (mm)<br>Conductor cross-<br>section, flexible<br>(AWG/mm<br>2)<br>Number of Poles<br>Circuits per foot<br>Torque(N•m)<br>Torque(lb-in)<br>Screw<br>WxHxD(mm)<br>1-Pole<br>2-Pole<br>3-Pole|600V<br>70A<br>0.625 / 15.88<br>18~4 / 1.0~25<br>1 - 3<br>19<br>3.6<br>32<br>1/4 - 28<br>18.5 x 47.0 x 45.6<br>34.0 x 47.0 x 45.6<br>49.5 x 47.0 x 45.6|||**Technical Data**<br>Rated voltage<br>Rated Current<br>Center spacing in (mm)<br>Conductor cross-<br>section, flexible<br>(AWG/mm<br>2)<br>Number of Poles<br>Circuits per foot<br>Torque(N•m)<br>Torque(lb-in)<br>Screw<br>WxHxD(mm)<br>1-Pole<br>2-Pole<br>3-Pole|600V<br>45A<br>0.625 / 15.88<br>Ring Terminals<br>Only<br>1 - 3<br>19<br>2.7<br>24<br>#10-32<br>18.5 x 49.1 x 62.1<br>34.4 x 49.1 x 62.1<br>50.3 x 49.1 x 62.1||
|**Colors**<br>**Cat. No.**<br> White (1-Pole)<br>PLU1-WH<br> White (2-Pole)<br>PLU11-WH<br> White (3-Pole)<br>PLU111-WH<br>**Accessories**<br>**Cat. No.**<br>**Colors**<br>**Cat. No.**<br> White (1-Pole)<br>PSU1-WH<br> White (2-Pole)<br>PSU11-WH<br> White (3-Pole)<br>PSU111-WH<br>**Accessories**<br>**Cat. No.**<br>a|||||||
|2 circuits|JN1||||||
||MT12-1-2||||MT12-1-2||
|C-Rail (AL)|NFTA Series|||C-Rail (AL)|NFTA Series||
|C-Rail (low profile)|NRA Series|||C-Rail (low profile)|NRA Series||
**==> picture [221 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions - in (mm) Dimensions - in (mm)<br>1.85 1.93<br>(47.49) 1.87 (37.59) 1.48 (46.99) (15.88)0.625 (37.64) 1.48 (49.12)<br>2.44<br>(62.10)<br>is<br>1.30<br>ie (31.75) 1.25 (11.10) 0.43 (33.00)<br>**----- End of picture text -----**<br>
For more information, visit www.cooperbussmann.com/DatasheetsEle
**363**
**Connectors**
## **Multi-Pole Panel Mount Blocks**
|Panel Mount Blocks|**KT3**|**KT3**||**KT4**||||**PLK3**|**PLK3**||
|---|---|---|---|---|---|---|---|---|---|---|
|Multi-pole panel mount terminal|**Approval**|||**Approval**||||**Approval**|||
|blocks provide a compact, high|**Technical Data**|||**Technical Data**||||**Technical Data**|||
|density circuit connection solution|Rated voltage|600V||Rated voltage|600V|||Rated voltage|600V||
|without the necessity of a mounting|Rated Current|40A||Rated Current|30A|||Rated Current|40A||
|rail. These products are designed to|||||||||||
|be nested together to form one string|Center spacing in (mm)|0.39 / 9.91|0.39 / 9.91|Center spacing in (mm)|0.25 / 6.35|0.25 / 6.35||Center spacing in (mm)|0.39 / 9.91|0.39 / 9.91|
|of circuit connections.|Conductor cross-|||Conductor cross-||||Conductor cross-|||
|CSA 15364 (excluding PLK3)|section, flexible<br>(AWG/mm<br>2)<br>Number of Poles<br>Circuits per foot<br>Torque(N•m)<br>Torque(lb-in)<br>Screw<br>WxHxD(mm)|22~8 / 0.5~10<br>3<br>28<br>2<br>18<br>#8-32<br>59.5 x 31.8 x 31.0||section, flexible<br>(AWG/mm<br>2)<br>Number of Poles<br>Circuits per foot<br>Torque(N•m)<br>Torque(lb-in)<br>Screw<br>WxHxD(mm)|22~10 / 0.5~6<br>4<br>48<br>2<br>18<br>#6-32<br>43.8 x 34.0 x 32.2|||section, flexible<br>(AWG/mm<br>2)<br>Number of Poles<br>Circuits per foot<br>Torque(N•m)<br>Torque(lb-in)<br>Screw<br>WxHxD(mm)|22~8 / 0.5~10<br>3<br>28<br>2<br>18<br>#8-32<br>65.7 x 46.9 x 45.5||
|Jumper<br>Block<br>c~~a~~)|**Colors**<br>**Cat. No.**<br> White (Standard)<br>KT3-WH<br> Black<br>KT3-BK<br> Red<br>KT3-RE<br>**Accessories**<br>**Cat. No.**<br>2 circuits<br>JN3<br>**Colors**<br>**Cat. No.**<br> White*<br>KT4-WH-A<br> White*<br>KT4-WH-B<br> Black<br>KT4-BK<br>**Accessories**<br>**Cat. No.**<br>4 circuits<br>JN4<br>**Colors**<br>**Cat. No.**<br> White (Standard)<br>PLK3-WH<br>**Accessories**<br>**Cat. No.**<br>2 circuits<br>JN3<br>=<br>e@<br>O<br>oO<br>e<br>e<br>SSES||||||||||
|Marking Tape||MT12-1-2|||MTC6||||MT12-1-2||
|Mounting|Mounting Foot|KAD||||||Mounting Foot|KAD||
**==> picture [118 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Panel Mount Blocks<br>**----- End of picture text -----**<br>
Multi-pole panel mount terminal blocks provide a compact, high density circuit connection solution without the necessity of a mounting rail. These products are designed to be nested together to form one string of circuit connections.
UL E62622 CSA 15364 (excluding PLK3)
**==> picture [354 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions - in (mm) Dimensions - in (mm) Dimensions - in (mm)<br>0.98 0.37<br>(47.63) 1.87 (31.75) 1.25 (6.35) 0.25 (24.99) (9.40)<br>w i n ce | el 1.46 0.56<br>(31.04) 1.22 0.62 1.26 (37.22) (14.22)<br>i e (15.88) (32.23)<br>#8 screw clearance 1.79<br>KAD (45.52)<br>end mtg.<br>adapter ccsisc ll (31.75) 1.25 7 a ur aa=<br>2.34 1.25 (34.04) 1.34 (46.86) 1.84<br>ees (59.51) (31.75) 4<br>*The KT4 products are designed to be nested<br> together to form one string of circuit<br> connections. When used in series, order<br>t b KT4 WH A d KT4 WH B<br>**----- End of picture text -----**<br>
For more information, visit www.cooperbussmann.com/DatasheetsEle
**364**
**Connectors**
## **Quick Connect Blocks**
For more information, visit www.cooperbussmann.com/DatasheetsEle
**365**
**Connectors**
## **Double Row Terminal Blocks**
## **Series TB100**
## **Specifications**
**Rating** : 30A, 300V*
**Center Spacing** : 0.375˝ or 3/8˝ (9.52mm)
**Wire Range** : #14 - 22 AWG Cu
**==> picture [48 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB100-08<br>**----- End of picture text -----**<br>
**Screw Size** : #6-32 philslot screws
**Torque Rating** : 9 lb-in
**Distance Between Barriers** : 0.30˝ (7.62mm)
**Mounting** : #6 screws
- **Operating Temperature** : 130°C (266°F) max., -40°C (-40°F) min.
**==> picture [62 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB100-04SP<br>**----- End of picture text -----**<br>
**Materials** : Molded base: Black, UL rated 94V0 thermoplastic
Terminal plating: Tin over brass; Screws: Zinc-plated steel
**Breakdown Voltage** : 3600V
**Agency Information** : UL File E62622/CSA File 47235; IEC Compliance; CE Certified
* Max rating shown; some options may be rated lower.
## **Dimensions - in**
|**PolesA**<br>**B**|**PolesA**<br>**B**|**Poles**<br>**A**<br>**B**|
|---|---|---|
|**Poles A**<br>**B**<br>~~_~~|**Poles A**<br>**B**<br>~~_~~|**Poles**<br>**A**<br>**B**|
|02<br>1.40<br>1.12<br>~~____~~|14<br>5.90<br>5.62<br>~~____~~|26<br>10.40<br>10.12|
|03<br>1.78<br>1.50<br>~~____~~|15<br>6.28<br>6.00<br>~~____~~|27<br>10.78<br>10.50|
|04<br>2.16<br>1.88<br>~~___~~|16<br>6.66<br>6.38<br>~~___~~|28<br>11.16<br>10.88|
|05<br>2.53<br>2.25<br>~~_____~~|17<br>7.03<br>6.75<br>~~_____~~|29<br>11.53<br>11.25|
|06<br>2.90<br>2.62<br>~~_____~~|18<br>7.40<br>7.12<br>~~_____~~|30<br>11.90<br>11.62|
|07<br>3.28<br>3.00<br>~~__~~|19<br>7.78<br>7.50<br>~~__ee~~|31<br>12.28<br>12.00|
|08<br>3.66<br>3.38<br>~~__~~|20<br>8.16<br>7.88<br>~~__ee~~|32<br>12.66<br>12.38|
|09<br>4.03<br>3.75<br>|21<br>853<br>8.25<br>~~ee~~|33<br>1303<br>12.75|
|09<br>4.03<br>3.75<br>10<br>4.40<br>4.12<br>|21<br>8.53<br>8.25<br>22<br>8.90<br>8.62<br>~~ee~~<br>~~J~~|33<br>13.03<br>12.75<br>34<br>13.40<br>13.12|
|11<br>4.78<br>4.50|23<br>9.28<br>9.00<br>~~J~~|35<br>13.78<br>13.50|
|11<br>4.78<br>4.50<br>12<br>5.16<br>4.88<br>~~Co~~|23<br>9.28<br>9.00<br>24<br>9.66<br>9.38<br>~~J~~<br>~~Co~~|35<br>13.78<br>13.50<br>36<br>14.16<br>13.88|
|13<br>5.53<br>5.25<br>~~Co~~|25<br>10.03<br>9.75<br>~~J~~<br>~~Co~~||
**==> picture [64 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB100- in (mm)<br>**----- End of picture text -----**<br>
**==> picture [204 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>0.14 0.14<br>B<br>(3.5) (3.5)<br>a aicsicsisisisisioiai eaan<br>0.88<br>0.31 (7.9)<br>(22.3)<br>1 REPS ERR<br>po rt p t Ft 0.375 Fh FF 0.3 F 0 E) —<br>0.17 dia. | i (9.5) (7.6) +| | -<br>(4.3)<br>0.41<br>0.25 (6.3) (10.4)<br>- [HSSSSSesesh] (O/][QY/J[QJ[I@JJa{J[ja{la/iajjca<br>**----- End of picture text -----**<br>
## **Catalog Number Build-A-Code**
Series Poles Screw Options Marking/Cover Hardware Options ~~**o**~~ **TB100** — ~~o oooo}.~~ 4goooo **02** to **36** Blank - steel philslot, zinc-plated **L1** to **L6 QC1** to **QC20** - quick connects **00** - screws shipped bulk Marking Options (See page 318) **B** - brass philslot, nickel-plated Marker Strips (See page 319) **SP** - steel Sems philslot, zinc-plated Special Markings (See page 319) **Custom Options**** Covers (See page 318) **J101** - flat slip-on jumper (2 position only)
- **0J2** - over barrier jumpers
- **0J4** - over barrier jumpers
****** Contact factory for pole configuration.
For more information, visit www.cooperbussmann.com/DatasheetsEle
**366**
**Connectors**
## **Double Row Terminal Blocks**
## **Screw Options**
**==> picture [141 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
B SP<br>Brass Philslot Steel SEMS<br>Nickel-Plated Philslot Zinc-Plated<br>**----- End of picture text -----**<br>
## **Hardware Options**
**Quick Connects – Assembled:** Terminals 0.187” x 0.020”. Maximum current rating 13 amps. For other orientations, contact Bussmann.
**==> picture [242 x 40] intentionally omitted <==**
**==> picture [358 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC1 QC2 QC3 QC4 QC5 QC6 QC7<br>QC8 QC9 QC10 QC11 QC12 QC13<br>QC14 QC15 QC16 QC17 QC18 QC19 QC20<br>**----- End of picture text -----**<br>
**Quick Connects – Bulk:** minimum order per part number – 100 pieces.
**==> picture [322 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC101-J QC102-J QC103-J<br>Flat – none QC 45° – none QC 90° – none<br>QC104-J QC105-J QC106-J QC107-J QC108-J QC109-J<br>Flat – Flat Flat – QC 45° Flat – QC 90°QC 45° – QC 45° QC 45° – QC 90°QC 90° – QC 90°<br>**----- End of picture text -----**<br>
**Jumpers – Bulk:** minimum order per part number – 100 pieces. Contact Bussmann for jumper assembly.
**==> picture [208 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
J101 OJ2 OJ4<br>Flat slip-on Slip-on over barrier Closed over barrier<br>(Bulk: J101-J) (Bulk: OJ2-J) (Bulk: OJ4-J)<br>**----- End of picture text -----**<br>
For more information, visit www.cooperbussmann.com/DatasheetsEle
**367**
**Connectors**
## **Double Row Terminal Blocks**
## **Series TB200 & TB200HB**
**Specifications Ratings:** Volts: — 300V* (TB200)
— 600V* (TB200HB)
Amps: — 30A*
**Center Spacing** : 0.437˝ or 7/16˝ (11.10mm)
**Wire Range** : #12 - 22 AWG Cu **Screw Size** : #6-32 philslot screws
**Torque Rating** : 9 lb-in
**Distance Between Barriers** : 0.353˝ (8.97mm)
**Mounting** : #6 screws
**==> picture [63 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB200-10SP<br>|<br>r<br>TB200HB-06<br>**----- End of picture text -----**<br>
**Operating Temperature** : 130°C (266°F) max., -40°C (-40°F) min.
TB200 - in (mm)
**Materials** : Molded base: Black, UL rated 94V0 thermoplastic
**==> picture [501 x 266] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|A|
|Terminal plating: Tin over brass; Screws: Zinc-plated steel|
|0.16|0.16|
|B|
|Breakdown Voltage|: 4800V|(4.0)|(4.0)|
|Agency Information|: UL File E62622, CSA File 47235 &|0.44 (11.2)|1.12|
|(28.4)|
|15364; IEC Compliance; CE Certified|
|* Max rating shown; some options may be rated lower.|Dimensions - in|0.17 dia. (4.3)|(11.1) 0.437|0.35(8.9) 3|—|
|Poles|A|B|Poles|A|B|Poles|A|B|.|0.56|
|02|1.63|1.31|12|6.00|5.68|22|10.37|10.06|0.31 (7.8)|i|(14.2)|(]|
|03|2.07|1.75|13|6.44|6.12|23|10.81|10.50|:|
|04|2.51|2.18|14|6.87|6.56|24|11.25|10.93|
|05|2.94|2.62|15|7.31|7.00|25|11.68|11.37|TB200HB|
|06|3.38|3.06|16|7.75|7.43|26|12.12|11.81|
|07|3.82|3.50|17|8.19|7.87|27|12.56|12.25|A|
|08|4.25|3.93|18|8.62|8.31|28|13.00|12.68|
|09|4.69|4.37|19|9.06|8.75|29|13.44|13.12|0.16|B|0.16|
|(4.0)|(4.0)|
|10|5.13|4.81|20|9.50|9.18|30|13.87|13.56|
|Saeeesoeet|
|11|5.57|5.25|21|9.94|9.62|||
|1” = 25.4mm.|0.44 (11.2)|(22.8)0.90|(34.8)1.37|
|0.437|0.353|
|0.17 dia.|s|i|e|(11.1)|(8.9)|1|Fe|0.17 x 0.22 slots|
|(4.3)|(4.3 x 5.6)|
|an a|
|0.75|
|0.33 (8.4)|7_eeeeteeeeL=|(19.0)|
**----- End of picture text -----**<br>
## **Catalog Number Build-A-Code**
Series Poles Screw Options Marking/Cover Hardware Options —oooo00ooolUlU™U™U™C~«CNW.COCOC~C~‘“(‘(<(<Ci;iCQTT— **TB** — oo ~~wes~~ **200** - Standard **02** to **30** Blank - Steel philslot, zinc-plated **L1** to **L6** - Marking Options (See page 318) **QC1** to **QC20** - Quick connects **200HB** - High barrier **00** - Screws shipped bulk Special Markings (See page 318)
- **L1** to **L6** - Marking Options (See page 318) **QC1** to **QC20** - Quick connects Special Markings (See page 318) Covers (See page 318) Marking Strips (See page 319) **Custom Options****
- **B** - Brass philslot, nickel-plated **BS** - Brass Sems philslot, nickel-plated **SP** - Steel Sems philslot, zinc-plated **P** - Steel Sems (P-style) **ST** - Stainless steel, philslot **SS** - Stainless steel Sems, philslot
- **J201** - Flat slip-on jumper (2 position only)
- **0J3** - Over barrier jumpers
- **0J5** - Over barrier jumpers **0J7** - Over barrier jumpers
****** Contact factory for pole configuration
For more information, visit www.cooperbussmann.com/DatasheetsEle
**368**
**Connectors**
## **Double Row Terminal Blocks**
## **Screw Options**
**==> picture [421 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
B BS SP P ST SS<br>Brass Philslot Brass SEMS Steel SEMS Steel SEMS Stainless Steel Stainless Steel<br>Nickel-Plated Philslot Nickel-Plated Philslot Zinc-Plated (P-Style) Philslot SEMS Philslot<br>Bulk: B001-7016-J B001-7019-J B001-7007-J B001-7000-J F507-J B001-7085-J<br>**----- End of picture text -----**<br>
## **Hardware Options**
**Quick Connects – Assembled:** Terminals 0.25” x 0.031”. Maximum current rating 20 amps. For other orientations, contact Bussmann.
**==> picture [242 x 39] intentionally omitted <==**
**==> picture [356 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC1 QC2 QC3 QC4 QC5 QC6 QC7<br>QC8 QC9 QC11 QC10 QC12 QC13<br>QC14 QC15 QC16 QC17 QC18 QC19 QC20<br>**----- End of picture text -----**<br>
**Quick Connects – Bulk:** minimum order per part no. – 100 pieces.
**==> picture [312 x 64] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC201-J QC202-J QC203-J<br>QC 45° – blank Flat – blank QC 90° – blank<br>QC204-J QC205-J QC206-J QC207-J QC208-J QC209-J<br>Flat – Flat Flat – QC 45° Flat – QC 90° QC 45° – QC 45° QC 45° – QC 90° QC 90° – QC 90°<br>**----- End of picture text -----**<br>
**Jumpers – Bulk:** minimum. order per part no. – 100 pieces. Contact Bussmann for jumper assembly.
**==> picture [212 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
J201 OJ3 OJ5<br>Flat slip-on Slip-on over Closed over<br>(not available on TB200HB) barrier for TB200HB barrier for TB200HB<br>(Bulk: J201-J) (Bulk: OJ3-J) (Bulk: OJ5-J)<br>**----- End of picture text -----**<br>
**==> picture [47 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
OJ7<br>Closed over<br>barrier for TB200<br>(Bulk: OJ7-J)<br>**----- End of picture text -----**<br>
For more information, visit www.cooperbussmann.com/DatasheetsEle
**369**
**Connectors**
## **Double Row Terminal Blocks**
## **Series TB300 & TB345**
**Specifications Ratings:**
Volts: — 600V* Amps: — 30A* (TB300) — 45A (TB345)
**Center Spacing** : 0.562” or 9/16” (14.28mm) **Wire Range** : #8 - 22 AWG Cu
**Screw Size** : TB300 – #8-32 philslot screws
TB345 – #10-32 philslot screws
**Torque Rating** : #8 screws - 16 lb-in;
#10 screws - 20 lb-in
**==> picture [62 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB300-08<br>TB345-06SP<br>**----- End of picture text -----**<br>
**Distance Between Barriers** : 0.41” (10.5mm)
**Mounting** : TB300 – #8 screws; TB345 – #10 screws **Operating Temperature** : 130°C (266°F) max., -40°C (-40°F) min.
**Material** : Molded base: Black, UL rated 94V0 thermoplastic Terminal plating: Tin over brass; Screws: Zinc-plated steel **Breakdown Voltage** : 7500V
**Agency Information** : UL File E62622, CSA File 47235; IEC Compliance; CE Certified
* Max rating shown; some options may be rated lower.
|**Poles**<br>**A**<br>**B**|**Poles**<br>**A**<br>**B**|**Poles**<br>**A**<br>**B**|
|---|---|---|
|02<br>2.13<br>1.69|10<br>6.62<br>6.19|18<br>11.12<br>10.68|
|03<br>2.69<br>2.25|11<br>7.18<br>6.75|19<br>11.68<br>11.25|
|04<br>3.25<br>2.81|12<br>7.75<br>7.31|20<br>12.24<br>11.81|
|05<br>3.81<br>3.37|13<br>8.31<br>7.87|21<br>12.80<br>12.37|
|06<br>4.37<br>3.94|14<br>8.87<br>8.44|22<br>13.37<br>12.93|
|07<br>4.94<br>4.50|15<br>9.43<br>9.00|23<br>13.93<br>13.50|
|08<br>5.50<br>5.06|16<br>9.99<br>9.56|24<br>14.49<br>14.06|
|09<br>6.06<br>5.62|17<br>10.56<br>10.12||
TB300 & TB345 - in (mm)
**==> picture [240 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
8-32 binding head screw - TB 300<br>10-32 binding head screw - TB 345<br>A<br>0.22<br>B<br>(5.6)<br>4 SEES ——T<br>0.50 (12.7) (22.8) 0.90 (33.8) 1.33<br>0.56<br>(14.2) 0.56 0.412 0.21 x 0.25 slots<br>0.21dia. nae (14.2) (10.4) dk (5.3 x 6.3)<br>(5.3)<br>0.81<br>0.33 (8.4) (20.5)<br>.HbR REESE=<br>**----- End of picture text -----**<br>
## **Catalog Number Build-A-Code**
Series Poles Screw Options **TB** — ~~“poo oo coo~~ **300** = 8-32 screw **02** to **24 Blank** = Steel philslot, zinc-plated **345** = 10-32 screw **00** = Screws shipped bulk
- **00** = Screws shipped bulk
- **B** = Brass philslot, nickel-plated **BS** = Brass Sems philslot, nickel-plated (TB300 only)
~~oo~~ Marking/Cover ~~oooo—~~ Hardware Options **L1** to **L6** Marking Options (pg 318) **QC1** to **QC20** = Quick connects (TB300 only) Special Markings (pg 318) Covers (pg 318) Marking Strips (pg 319)
- **SP** = Steel Sems philslot, zinc-plated (TB300 only)
**ST** = Stainless steel, philslot
**Custom Options J301** = Flat slip-on jumper **OJ6** = Over barrier jumper **OJ11** = Over barrier jumper
For more information, visit www.cooperbussmann.com/DatasheetsEle
**370**
**Connectors**
## **Double Row Terminal Blocks**
## **Screw Options**
**==> picture [313 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
B BS SP ST<br>Brass Philslot Brass SEMS Steel SEMS Stainless Steel<br>Nickel-Plated Philslot Nickel-Plated Philslot Zinc-Plated Philslot<br>TB300 Blk: B001-7018-J B001-7015-J B001-7017-J B001-7063-J<br>TB345 Blk: B500-023-028-J B001-7064-J<br>**----- End of picture text -----**<br>
## **Hardware Options**
**Quick Connects – Assembled:** TB300 only. Terminals 0.25” x 0.031”. Maximum current rating 20 amps. For other orientations, contact Bussmann.
**==> picture [242 x 39] intentionally omitted <==**
**==> picture [356 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC1 QC2 QC3 QC4 QC5 QC6 QC7<br>QC8 QC9 QC10 QC11 QC12 QC13<br>QC14 QC15 QC16 QC17 QC18 QC19 QC20<br>**----- End of picture text -----**<br>
**Quick Connects – Bulk:** (*TB300 only) minimum order per part number. – 100 pieces.
**==> picture [338 x 65] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC201-J QC202-J QC203-J<br>Flat – blank QC 45° – blank QC 90° – blank<br>QC204-J QC205-J QC206-J QC207-J QC208-J QC209-J<br>Flat – Flat Flat – QC 45° Flat – QC 90° QC 45° – QC 45° QC 45° – QC 90° QC 90° – QC 90°<br>**----- End of picture text -----**<br>
**Jumpers – Bulk:** minimum order per part number – 100 pieces. Contact Bussmann for jumper assembly.
J301 OJ6 OJ11 Flat slip-on(TB300 only) Closed over barrier Slip-on over barrier (Bulk: J301-J) (Bulk: OJ6-J) (Bulk: OJ11-J)
For more information, visit www.cooperbussmann.com/DatasheetsEle
**371**
**Connectors**
## **Marking Options and Covers for Double Row Terminal Blocks**
**==> picture [524 x 197] intentionally omitted <==**
**----- Start of picture text -----**<br>
Standard Marking<br>Standard markings are applied directly to the side(s) of a 1 2 3 3 2 1<br>block. The standard marking color is white. The standard<br>numeral height is 0.125 inches (3.17mm). L1 L2 L3<br>Note: Blocks marked on both sides require a different code<br>for each side. Example: Style L1 on one side of the block<br>requires Style L2 on the other side to ensure common<br>terminal marking. To order, add appropriate suffix (L1, L2, L3,<br>L4, L5 and/or L6) to block catalog number in the proper<br>L4 L5 L6<br>sequence.<br>Special Marking K MASTER 3AC G REDBLUBLK 3<br>Special markings are available at an additional charge<br>Drawing(s) must be submitted to ensure accuracy of part<br>required. Consult Bussmann for price and delivery.<br>Note: Marking is not available on TB400 Series OUTPUT 134 GND M 300VMAX<br>1 2 3<br>3 2 1<br>20A 4<br>INPUT 134 MB<br>1 2 3 3 2 1<br>5<br>A<br>**----- End of picture text -----**<br>
## **Covers**
Covers prevent personnel, screws and foreign items from contacting live terminals, and are available in white or clear plastic. Two cover clips are supplied with each cover. The cover width is 1.31 inches (33.3mm).
All covers must be ordered separately.
Example: 10 position cover, white, TB100 Series = Catalog Number **X12010** .
**==> picture [253 x 122] intentionally omitted <==**
## **Catalog Number Build-A-Code**
**==> picture [373 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
Series Cover Strip Poles High Barrier Option Only<br>X<br>120 - TB100/white 02 to 36 (TB100) HB = High Barrier<br>119 - TB100/clear 02 to 30 (TB200/TB200HB)<br>220 - TB200/TB200HB - white 02 to 24 (TB300/TB345)<br>219 - TB200/TB200HB - clear<br>320 - TB300 & TB345 - white<br>319 - TB300 & TB345 - clear<br>**----- End of picture text -----**<br>
Note: Covers are not available on TB400 Series.
Cover Clips – Bulk
Part Number **DD1-J** – TB100 Series **DD2-J** – TB200 Series **DD2HB-J** – TB200HB Series **DD3-J** – TB300 Series
For more information, visit www.cooperbussmann.com/DatasheetsEle
**372**
**Connectors**
## **Top & Bottom Marking Strips for Double Row Terminal Blocks**
**==> picture [253 x 126] intentionally omitted <==**
## **Top Marker Strips**
Top mounting marker strips are available in white (opaque) plastic. Two cover clips are supplied with each marker strip.
All top marker strips must be ordered separately.
Example: 12 position cover, TB200, 0.032” x 0.312” = Catalog Number **X20312** .
Example: 12 position cover, TB200HB, 0.06” x 0.50” = Catalog Number **X23312HB** .
## **Catalog Number Build-A-Code**
Poles High Barrier Option Only **02** to **36** (TB100) **HB** = High Barrier **02** to **30** (TB200/TB200HB) **02** to **24** (TB300/TB345)
Series Top Marker Strip **X 133** - TB100 (0.060 thk x 0.500 w) **103** - TB100 (0.032 thk x 0.312 w) **233** - TB200/TB200HB (0.060 thk x 0.500 w) **203** - TB200/TB200HB (0.032 thk x 0.312 w) **333** - TB300 & TB345 (0.060 thk x 0.500 w) **303** - TB300 & TB345 (0.032 thk x 0.380 w)
Note: Marking Strips are not available on TB400 Series
## **Bottom Marker Strips**
Bottom mounting marker strips are made of black PVC, 0.030” thick. Space is available to handle most marking situations. All marker strips must be ordered separately.
To order, specify part number and required marking orientation: (BF) bottom forward, (BR) bottom reverse, (TF) top forward, or (TR) top reverse. Consult factory for specials.
Example: 13 position strip, TB100 with no markings, space for marking one side = Catalog Number **X10513** .
Standard numeral height is 0.125”. Standard markings are 0-99. Special markings are available on special order. Drawing(s) must be submitted to ensure accuracy of part required.
**==> picture [253 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
Space for marking one side Space for marking two sides<br>**----- End of picture text -----**<br>
## **Dimensions (in)**
|**Dim.**|**TB100**|**TB200**|**TB200HB **|**TB300**|**TB345**|**TB400**|
|---|---|---|---|---|---|---|
|A|1.13|1.37|1.62|1.58|1.58|N/A|
|B|1.38|1.62|1.81|1.81|1.81|N/A|
## **Catalog Number Build-A-Code**
Series Bottom Marker Strip **X**
**105** = TB100/marking one side **101** = TB100/marking both sides
- **205** = TB200/marking one side **201** = TB200/marking both sides **295** = TB200HB/marking one side **291** = TB200HB/marking both sides **305** = TB300 & TB345/marking one side **301** = TB300 & TB345/marking both sides
Poles
**02** to **36** (TB100) **02** to **30** (TB200/TB200HB) **02** to **24** (TB300/TB345)
Orientation **BF** = Bottom forward **BR** = Bottom reverse **TF** = Top forward **TR** = Top reverse
Note: Marking Strips are not available on TB400 Series.
For more information, visit www.cooperbussmann.com/DatasheetsEle
**373**
**Connectors**
## **Double Row Terminal Blocks**
## **Series TB400**
**Specifications Ratings:** Volts: — 600V Amps: — 75A
**Center Spacing** : 0.687˝ or 11/16˝ (17.45mm) **Wire Range** : #6-14 AWG Cu **Screw Size** : #10-32 philslot screws **Torque Rating** : 20 lb-in
**==> picture [48 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB400-05<br>**----- End of picture text -----**<br>
**Distance Between Barriers** : 0.56˝ (14.3mm)
**Mounting** : #10 screws
**Operating Temperature** : 130°C (266°F) max., -40°C (-40°F) min.
**Material** : Molded base: Black, UL rated 94V0 thermoplastic Terminal plating: Tin over brass; Screws: Zinc-plated steel
## TB400 - in (mm)
**Breakdown Voltage** : 7500V
**Agency Information** : UL File E62622, CSA File 47235; IEC Compliance; CE Certified
## **Dimensions - in**
|**Poles**<br>**A**<br>**B**<br>**Poles**<br>**A**<br>**B**<br>**Poles**<br>**A**<br>**B**<br>02<br>2.51<br>2.06<br>06<br>5.26<br>4.81<br>10<br>8.01<br>7.56<br>03<br>3.20<br>2.75<br>07<br>5.95<br>5.50<br>11<br>8.70<br>8.25<br>04<br>3.89<br>3.44<br>08<br>6.64<br>6.19<br>12<br>9.39<br>8.94|
|---|
|**Screw Options**<br>05<br>4.58<br>4.13<br>09<br>7.33<br>6.88<br>1” = 25.4mm.<br>~~Be~~<br>e<br>&|
B ST Brass Philslot Stainless Steel Nickel-Plated Philslot Bulk: B500-023-028-J B001-7064-J
**==> picture [223 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>B<br>0.22<br>(5.6)<br>0.15 dia.<br>(3.8)<br>0.625 1.12<br>(15.9) (28.4)<br>eile<br>0.22 dia. (5.6)<br>0.68 7 0.687 0.562<br>(17.4) (17.4) (14.3)<br>1.81<br>(46.0)<br>i eel Thy<br>0.76<br>0.46 (11.7) (19.3)<br>“(RBBB ieo<br>1.34<br>. =<br>(34.0)<br>**----- End of picture text -----**<br>
## **Hardware Options**
OJ14: Closed over barrier (Bulk:OJ14-J)
## **Catalog Number Build-A-Code**
Series Poles Screw Options Marking Custom Options SS ~~EERE~~ **TB400** ~~TEE=T=~~ – EIa/= = **02** to **12 Blank** = Steel philslot, zinc-plated Not available **OJ14*** - Jumper over barrier **00** = Screws shipped bulk **B** = Brass philslot, nickel-plated **ST** = Stainless steel, philslot
*Contact factory for pole configuration.
For more information, visit www.cooperbussmann.com/DatasheetsEle
**374**
**Connectors**
## **Double Row Terminal Blocks**
## **Series KU**
**Specifications Ratings:** Volts:— 600V Amps:— 60A*
**Center Spacing** : 0.625˝ (15.88mm)
**Number of Poles** : 2- to 12-poles Wire Range** : #6-22 AWG Cu
**Screw Size:** #10-32
**Torque Rating:** 20 lb-in **Distance Between Barriers:** 0.437˝ (11.09mm)
**Mounting** : Panel Mount
**Material** : Molded base: Black, UL rated 94V1 Noryl Terminal plating: Nickel over brass
**Operating Temperature** : 105°C max.
**Agency Information** : UL File E62622, CSA File 47235 * 60A rating achieved with #6 copper wire crimped to ring terminal. ** Only even number pole configurations (3-pole = exception).
**Dimensions - in KU KUX Only Poles A B A** 02 2.50 1.62 2.00 03 3.12 2.25 2.62 ~~Oc~~ 04 3.75 2.87 3.25 06 5.00 4.12 4.50 ~~Ce~~ 08 6.25 5.37 5.75 10 7.50 6.62 7.00 12 8.75 7.87 8.25 1” = 25.4mm.
**==> picture [225 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
Series KU - in (mm)<br>B<br>0.62<br>(15.9)<br>2.00 1.50<br>(50.8) (38.1)<br>#10 screw<br>clearance<br>—_<br>W ISI N | | 1.2 5 A<br>0.43 (31.8)<br>(11.1)<br>a o n<br>0.50<br>(12.7)<br>e ee!<br>A<br>-<—— ——+ F<br>**----- End of picture text -----**<br>
## **Accessories*****
**==> picture [200 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
MTMU## NUM## JU12 NUE NUC##<br>Molded Marking Tape Molded Marking Jumper End Piece for NUC Cover<br>Matte Finish Tape 12 Circuits<br>**----- End of picture text -----**<br>
***Accessories must be orderd seperately.
## **Catalog Number Build-A-Code - KU Series**
Series Poles Screw Options – ~~Sooco ocooo~~ **KU** = Standard block **02** to **12 00** = Screws shipped bulk **KUX** = Short block **W** = Brass washer head, **KURL** = Standard w/removable link nickel-plated **KUXRL** = Short block w/removable link **P** = Steel screw w/pressure plate zinc-plated **BP** = Brass philslot, nickel-plated
~~oo~~ Covers ~~coo~~ Marking Strip **WC** = Top cover & **MT** = Matte finish 2 end plates **NU** = Numbered 1 to 12, horizontal **NUV** = Numbered 1 to 12, vertical **PT[†]** = Marker strip for cover
## **Catalog Number Build-A-Code - KU__SC Series**
Series Poles Screw Options – ~~qg000. cogo~~ **KUSC** = Standard w/shorting strap **02 to 12 00** = Screws shipped bulk & 4 shorting screws **W** = Brass washer head, **KUXSC** = Short block w/shorting strap nickel-plated & 4 Shorting screws **P** = Steel screw w/pressure plate zinc-plated **BP** = Brass philslot, nickel-plated
~~oo~~ Covers ~~ooo~~ Marking Strip **WC** = Top cover & **PT[†]** = Marker strip for cover 2 end plates **†** Requires WC cover option
For more information, visit www.cooperbussmann.com/DatasheetsEle
**375**
**Connectors**
## **Power Feed Through Terminal Blocks**
## **Series C7021**
**Specifications Description:** Power feed through terminal block with two rows 1 ⁄4-20 studs capable of accommodating the industry standard two-hole compression lugs on both studs in parallel.
## **Ratings:**
Volts: — 300V
Amps: — 115/175A* per pole
**Center Spacing:** 0.690" (17.5mm).
**Wire Range:** AWG #3/0-8.
**Poles:** 1- to 6-poles.
**Bolt Hole Spacing:** 0.625" or[5] ⁄8” (15.88mm).
**Stud:** Standard[1] ⁄4-20 stud (tin-plated brass) or optional M6 stud.
**Mounting:** #6 thread cutting screws (not included) or optional mounting ears.
**Torque Rating:** 36 lb-in.
**Operating Temperature:** 130°C.
**Agency Information:** UL/CSA; CE Certified.
*175 achieved using both studs in parallel, 115A using a single stud per line.
## **Typical Applications**
- Applications requiring up to 175A utilizing a 2-hole compression lug on[5] ⁄8" centers
- Input/output block for telecommunications power panels
**==> picture [249 x 369] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Dimensions - mm (in)|
|Catalog|
|Numbers|A|B|C|D|E|
|C7021-01-X|
|C7021-02-X|17.5 (0.69)|-|54.4 (2.14)|67.3 (2.65)|31.8 (1.25)|
|C7021-03-X|34.9 (1.37)|-|70.9 (2.83)|84.8 (3.34)|49.2 (1.94)|
|C7021-04-X|52.3 (2.06)|-|89.3 (3.52)|102.2 (4.02)|66.7 (2.63)|
|C7021-05-X|69.8 (2.75)|-|106.8 (4.20)|119.7 (4.71)|84.2 (3.31)|
|C7021-06-X|87.2 (3.44)|-|124.2 (4.89)|134.1 (5.40)|101.7 (4.00)|
|C7021-01N-X|
|C7021-02N-X|17.5 (0.69)|36.1 (1.42)|-|-|31.8 (1.25)|
|C7021-03N-X|34.9 (0.69)|53.5 (2.11)|-|-|49.2 (1.94)|
|C7021-04N-X|52.3 (2.06)|71.0 (2.80)|-|-|66.7 (2.63)|
|C7021-05N-X|69.8 (2.75)|88.4 (3.48)|-|-|84.2 (3.31)|
|a|C7021-06N-X|87.2 (3.44)|105.9 (4.17)|-|-|101.7 (4.00)|
|D|
|C|9.6|
|(0.62)15.8|(1.10)28.0|(0.38)|(2.19)55.7|
|5.4|
|(0.21)|“|j|o|A|B|EL|
|15.8|12.5|
|(0.62)|(0.49)|
|‘|e|lect.|Wu|Ø 9.0 TYP|
|7.9|||Org|a|(0.35)|
|(0.31)|A|1/4-20 UNC-2A|ø12.2 TYP|
|Thread TYP|(0.48)|
|B|
|17.5 TYP|
|(0.69)|
|15.0 TYP|
|(0.59)|24.0|
|(0.94)|
|(0.50)12.7|Blind Hole for #6Thread Cutting|
|14.5 TYP|Screw|
|(1.30)33.0|(0.57)|14.5 TYP(0.57)|
**----- End of picture text -----**<br>
- Use to eliminate busbars
## Panel Cutouts
**==> picture [171 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
E<br>A 14.2 1.6<br>( ø.56) rp (R.06)<br>30.0<br>(1.18)<br>**----- End of picture text -----**<br>
## Catalog Number Build-A-Code
**==> picture [348 x 75] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Series|Poles|Mount Ends|Studs|Hardware|
|———ot—“‘<‘<“<i—iaQUCSOStw|C7021 –|OO|OO|–|
|01 = 1-Pole (2 studs)|Blank = Mount ends|Blank = Standard|Blank = No hardware|
|02 = 2-Pole (4 studs)|N = No mount ends|M6 = M6 Studs|0 = Bulk pack, one set|
|03 = 3-Pole (6 studs)|1 = Bulk pack, two sets|
|04 = 4-Pole (8 studs)|2 = Assembled, bottom|
|05 = 5-Pole (10 studs)|3 = Assembled, top|
|06 = 6-Pole (12 studs)|4 = Assembled, both sets|
**----- End of picture text -----**<br>
For more information, visit www.cooperbussmann.com/DatasheetsEle
**376**
**Connectors**
## **Power Feed Through Terminal Blocks**
## **Series C7024**
**Specifications Description:** A power feed through terminal block with two rows of[1] ⁄4-28 studs capable of accommodating the industry standard two-hole compression lugs on[3] ⁄4" centers.
**Ratings:**
Volts: — 600V
Amps: — 115A per pole
**Center Spacing:** 0.75" (19.1mm). **Wire Range:** #2-8 AWG. **Poles:** 1 to 12.
**Bolt Hole Spacing:** 0.75" (19.1mm). **Stud:** Standard[1] ⁄4-28 stud (tin-plated bronze). **Torque Rating:** 36 lb-in.
**Operating Temperature:** 130°C.
**Agency Information:** UL/C-UL, CSA; CE Certified. **Flammability Rating:** UL 94V0.
## **Catalog Numbers**
|**Catalog**||**“A” Dimension- mm (in)**|**“A” Dimension- mm (in)**|
|---|---|---|---|
|**Number**<br>**Poles**<br>**±0.4 (±0.02)**<br>**“B” Dimension- mm (in)**<br>C7024-01<br>01<br>21.6 (0.85)<br>-<br>C7024-02<br>02<br>40.6 (1.60)<br>19.05 ±0.08 (0.750 ±0.003)<br>~~ee~~||||
|C7024-03|03|59.7 (2.35)|38.10 (1.500)|
|C7024-04|04|78.7 (3.10)|57.15 ±0.26 (2.250 ±0.010)|
|C7024-05|05|97.8 (3.85)|76.2 (3.00)|
|C7024-06|06|116.8 (4.60)|95.25 ±0.26 (3.750 ±0.010)|
|C7024-07|07|135.9 (5.35)|114.30 ±0.38 (5.250 ±0/015)|
|C7024-08|08|154.9 (6.10)|133.35 ±0.38 (5.25 ±0.015)|
|C7024-09|09|174.0 (6.85)|152.40 ±0.38 (6.00 ±0.015)|
|C7024-10|10|193.0 (7.60)|171.45 ±0.38 (6.750 ±0.015)|
|C7024-11|11|212.1 (8.35)|190.50 ±0.38 (7.500 ±0.015)|
|C7024-12|12|231.1 (9.10)|209.55 ±0.38 (8.250 ±0.015)|
## **Typical Applications**
- Applications requiring up to 115A utilizing a 2-hole compression lug on[3] ⁄4" centers
- Ideal as an input/output block for telecommunications power panels
- Use to eliminate busbars
## **Dimensions - mm (in)**
**==> picture [189 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø17.780TYP<br>[0.700]<br>A MIN. AT STUD PAD<br>N\A<br>INS<br>13.2TYP<br>[0.52]<br>0.5TYP<br>[0.02]<br>=<br>a T 16.53TYP<br>B [0.651]<br>A<br>28.0<br>[1.10]<br>17.8TYP 3.16TYP 2.70TYP<br>[0.70] [0.124] [0.106 ]<br>Ø14.4<br>19.06 ±0.08 [0.57]<br>[0.7500.003]<br>40.6<br>[1.60]<br>**----- End of picture text -----**<br>
## Catalog Number Build-A-Code
Series Poles ~~ee~~ C7024 – 01-12
For more information, visit www.cooperbussmann.com/DatasheetsEle
**377**
Open and enclosed | a i disconnect switches
Full range of disconnect switches with versatile options and accessories that ship within 24 hours
**378**
## **Disconnect Switches**
## **Section Contents**
**Page**
Scan this tag to get the latest product information for the New Family of Disconnect Switches and Accessories.
**Compact Circuit Protector (CCP) disconnect switches** 30A Class CC, Midget & 10x38.............................380-381 30A 60A and 100A Class CF .................................382-383 CCPB - Compact Circuit Protector Base ..............384-385 **UL 98 fused disconnect switches 30 to 800A** Introduction & Agency Information................................386 Product Line Summary..................................................387 30A Compact Class CC & Class J ........................388-389 30A Class J............................................................390-391 60A Compact Class J............................................392-393 60A Class J............................................................394-395 100A Class J..........................................................396-397 200A & 400A Class J .............................................398-400 600A Class J and 800A Class L ............................402-403 **UL 98 non-fused disconnect switches 30 to 1200A** Introduction & Agency Information................................404 Product Line Summary..................................................405 30A, 60A and 100A Compact................................406-407 100A, 200A and 400A Standard ............................408-409 600A, 800A, 1000A and 1200A Standard..............410-411 **UL 508 non-fused disconnect switches 16 to 80A** Introduction and Agency Information............................412 Product Line Summary..................................................413 16A, 25A, 40A, 63A and 80A Standard .................414-416 **Enclosed UL 98 & UL 508 disconnect switches** Introduction & Agency Information................................417 **Fused UL 98** 30A to 800A Enclosed Disconnects ......................418-419 **Non-Fused UL 98** 30 to 1200A Enclosed Disconnects.......................420-421 **Non-Fused UL 508** 16 to 80A Enclosed Disconnects...........................422-423 **Fused, dead front disconnect switches .................424**
**379**
**Disconnect Switches**
## **Compact Circuit Protector (CCP) Disconnect Switch—30A 1-, 2- & 3-Pole, Class CC, UL Midget & 10x38mm IEC**
**Switch** —_ Max Horsepower Rating Amp Fuse Number 120 240 480 600 Wire Part Rating Class of Poles Volts SCCR Vac Vac Vac Vac Wire Size Type* Number 30 CC 1 600Vac 200kA 0.5 — — — 75°C Cu CCP-1-30CC 30 CC 2 600Vac 200kA — 2 — — Single/Dual 75°C Cu CCP-2-30CC ~~———a~~ #18-6 Sol/Str 30 CC 3 600Vac 200kA — 3 4 7.5 75°C Cu CCP-3-30CC ze | i ~~—— || +~~ 30 UL Midget 1 240Vac[†] 10kA[†] — — — — Single 75°C Cu CCP-1-30M 32** 10x38 IEC ~~oo~~ 400Vac[†] 120kA[†] ~~a~~ #4 Sol/Str ~~—~~ 30 UL Midget 2 240Vac[†] 10kA[†] — — — — 75°C Cu CCP-2-30M ‘ely ~~BEREEEEEE~~ 32** 10x38 IEC ~~=e~~ 400Vac[†] 120kA[†] 30 UL Midget 3 240Vac[†] 10kA[†] — — — — 75°C Cu CCP-3-30M aon 3302** 10xCC38 IEC 1 48000VVdcac[†][†] 12200kAkA[†][†] — — ~~|~~ — — TerminalSpade[††] ~~——~~ 75°C Cu CCP-1-30DCC 30 CC 1 80Vdc† 10kA† — — — — 75°C Cu CCP-1-30DCM Lsee‘ ~~-—_+—==e==e=~~ 32*** 75°C or higher.10x38 IEC ~~—~~ | ** 32A Class aM, 25A Class gG. † SCCR May be lower, refer to installed fuse data sheets. †† Spade terminal, 30A max, insulated flange, wire size #12-10 for #8 stud. **Specifications** @ OO **Agency Information Features**
- CE Compliant
- RoHS Compliant
- For _**Class CC**_ fuse version
- UL 98 Listed, File E302370, Guide WHTY
- cULus to CSA Standard 22.2 No. 4-04, File 302370, Guide WHTY7
- IP20 Finger-safe construction with #10 or larger wire
- Switch interlock prohibits removing the fuse under load
## **Accessories**
- Auxiliary contacts
- PLC Wired remote fuse indication
- For _**UL Midget and 10X38 IEC**_ fuse version
- UL 508 Listed, File E161278, Guide 8R29
- cULus Certified 22.2 No. 14-05
- IEC 60947-3 AC23A
- IEC 60947-3 DC23A
## **Terminals**
- Single/dual conductor box lug or spade terminal suitable for line, load or accessory connection
- Torque: - #18-10 20Lb-In
- #8-4 35Lb-In
## **Storage and Operating Temperature**
- -20ºC to 75ºC*
- For fuse performance under or above 25ºC, consult fuse performance derating charts in the Bussmann publication titled _Selecting Protective Devices_ (SPD), reorder #3002.
## **Flammability Rating UL 94V0**
## **Lockout/Tagout Provisions**
- 4mm shank lock or standard pin-out devices
## **Mounting**
- 35mm DIN-Rail
## **Local Open Fuse Indication Minimum Voltage****
- 90Vac for AC versions
- 12Vdc for DC versions
- ** Circuit must be closed for indication light to illuminate.
## **Data Sheet: 1157**
||Switch Handle|Switch Handle|Switch Handle|||||||||||||||||Fuse Holder|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||||||||||Knob|
|Padlock Provision||||||||||||||||||||Circuit Marking|
|||||||||||||||||||||Area|
||||||||||||||||||||||
|Open Fuse<br>Indication Light<br>LS <br><N|||||||||||||||||||Spade Terminal<br>Box Lug<br> iy||
||||||||Oy|||||[P||||||||Terminal|
||||||||||||||||||||||
|**Available Bussmann Fuses**|||**Available Bussmann Fuses**||||||||||||||||||
|Class|Type|||||||||||||||||||Data Sheet #|
|CC|LP-CC Time-Delay, Current Limiting||LP-CC Time-Delay, Current Limiting|||||LP-CC Time-Delay, Current Limiting||||||||||||1023|
|CC|FNQ-R Time-Delay|||||||||||||||||||1014|
|CC|KTK-R Fast-Acting|||||||||||||||||||1015|
|M|FNM Time-Delay|||||||||||||||||||2028|
|M|FNQ Time-Delay|||||||||||||||||||1012|
|M|KTK Fast-Acting|||||||||||||||||||1011|
|M|BAF Fast-Acting|||||||||||||||||||2011|
|M|KLM Fast-Acting 600Vac/dc|||||||||||||||||||2020|
**380**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches** i
## **Compact Circuit Protector (CCP) Disconnect Switch—30A 1-, 2- & 3-Pole, Class CC, UL Midget & 10x38mm IEC**
## **Dimensions – mm (in)**
**==> picture [308 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
52.5<br>(2.1)<br>35<br>45 (1.4)<br>17.5<br>(1.8)<br>(0.7)<br>| ° |<br>(|ios QO 1) |||<br>J .<br>SoS 92.7 ( ee < = —<br>(3.7)<br>79.8 (3.1)<br>49.2 (1.9)<br>**----- End of picture text -----**<br>
Class CC, UL Midget & I0x38 IEC
Auxiliary Contacts PLC Indicator (Includes leads with spade terminals)
## **CCP-_-30_ Accessories**
|**CCP-_-30_ Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|**CCP-_-30_ Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|**CCP-_-30_ Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|**CCP-_-30_ Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|**CCP-_-30_ Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|**CCP-_-30_ Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|
|---|---|---|---|---|---|
|Auxiliary Contacts NO+NC<br>for Switch Status|1 per CCP|5A/240Vac|–|UL 98 Recognized,<br>cURus 22.2 No. 4-04,<br>IEC 60947-5-1 AC15|CCP-AUX*|
|Wired Remote Fuse Indication<br>for PLC Applications|1 per CCP|24Vdc|100Vac|UL 98 Recognized,<br>cURus 22.2 No. 4-04|CCP-PLC-IND*|
|* Refer to Data Sheet # 1157 for details.||||||
**381**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **Compact Circuit Protector (CCP) Disconnect Switch—30, 60 & 100A 1-, 2- & 3-Pole, Class CF CUBEFuse™**
|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Amp**<br>**Fuse**<br>**Number**<br>**120**<br>**240**<br>**480**<br>**600**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**Volts**<br>**SCCR**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Vac**<br>**Wire Size**<br>**Type***<br>**Number**|
|---|---|---|---|---|---|---|---|---|---|---|
|30<br>~~a~~|CF<br>~~a~~|1<br>~~a~~|600Vac <br>125Vdc<br>~~a~~|200kA<br>~~a~~|1.5<br>~~a~~|—<br>~~a~~|—<br>~~a~~|—<br>~~a~~|Single/Dual<br>#18-6 Sol/Str<br>Single<br>#4 Sol/Str<br>Spade<br>Terminal**<br>~~a~~<br>~~]~~)6h6UE<br>~~|tittrrrrryr;~~|75°C Cu CCP-1-30CF<br>75°C Cu CCP-2-30CF<br>#18-6 Sol/Str<br>75°C Cu CCP-3-30CF<br>75°C Cu CCP-1-60CF<br>75°C Cu CCP-2-60CF<br>75°C Cu CCP-3-60CF<br>ee<br>)6h6UE<br>CE<br>Ft|
|30<br>~~a~~<br>~~||~~|CF<br>~~a~~<br>||2<br>~~a~~<br>~~|~~|600Vac <br>125Vdc<br>~~a~~|200kA<br>~~a~~<br>~~|}~~|—<br>~~a~~<br>~~|}Py~~|3<br>~~a~~<br>~~Py~~|—<br>~~a~~<br>~~Py~~|—<br>~~a~~<br>~~]~~|||
|30<br>~~a~~<br>~~||~~|CF<br>~~a~~<br>||3<br>~~a~~<br>~~|~~<br>~~EP~~|600Vac <br>125Vdc<br>~~a~~<br>~~EP~~|200kA<br>~~a~~<br>~~|}~~<br>~~EP~~|—<br>~~a~~<br>~~|}Py~~|5<br>~~a~~<br>~~Py~~|15<br>~~a~~<br>~~Py~~|10<br>~~a~~<br>~~]~~|||
|60<br>~~a~~<br>~~| |~~<br>~~|tittrrrrryr;~~|CF<br>~~a~~<br>|<br>~~|tittrrrrryr;~~|1<br>~~a~~<br>~~|~~<br>~~EP~~<br>~~|tittrrrrryr;~~|600Vac <br>125Vdc<br>~~a~~<br>~~EP~~<br>~~|tittrrrrryr;~~|200kA<br>~~a~~<br>~~|}~~<br>~~EP~~<br>~~|tittrrrrryr;~~|3<br>~~a~~<br>~~|} Py~~<br>~~|tittrrrrryr;~~|—<br>~~a~~<br>~~Py~~<br>~~|tittrrrrryr;~~|—<br>~~a~~<br>~~Py~~<br>~~|tittrrrrryr;~~|—<br>~~a~~<br>~~]~~<br>~~|tittrrrrryr;~~|||
|60<br>~~|tittrrrrryr;~~|CF<br>~~|tittrrrrryr;~~|2<br>~~EP~~<br>~~|tittrrrrryr;~~|600Vac <br>125Vdc<br>~~EP~~<br>~~|tittrrrrryr;~~|200kA<br>~~EP~~<br>~~|tittrrrrryr;~~|—<br>~~|tittrrrrryr;~~|7.5<br>~~|tittrrrrryr;~~|—<br>~~|tittrrrrryr;~~|—<br>~~|tittrrrrryr;~~|||
|60<br>~~|tittrrrrryr;~~|CF<br>~~|tittrrrrryr;~~|3<br>~~|tittrrrrryr;~~|600Vac <br>125Vdc<br>~~|tittrrrrryr;~~|200kA<br>~~|tittrrrrryr;~~|—<br>~~|tittrrrrryr;~~|7.5<br>~~|tittrrrrryr;~~|20<br>~~|tittrrrrryr;~~|10<br>~~|tittrrrrryr;~~|||
|100<br>~~ae~~|CF<br>~~ae~~|1<br>~~ae~~|600Vac <br>~~ae~~|200kA<br>~~ae~~|5<br>~~ae~~|—<br>~~ae~~|—<br>~~ae~~|—<br>~~ae~~|Single<br>#8-10 Sol/Str<br>#8-1 Str<br>Dual #6 Str<br>Spade<br>Terminal**<br>~~ae~~|75°C Cu CCP-1-100CF<br>#8-10 Sol/Str<br>75°C Cu CCP-2-100CF<br>75°C Cu CCP-3-100CF<br>~~ae~~|
|100<br> ~~ae~~|CF<br>~~ae~~|2<br>~~ae~~|600Vac <br>~~ae~~|200kA<br>~~ae~~|—<br>~~ae~~|10<br>~~ae~~|—<br>~~ae~~|—<br>~~ae~~|||
|100<br>~~a~~|CF<br>~~a~~|3|600Vac|200kA|—|20|50|50|||
|* 75°C or higher.<br>** Spade terminal, 30A max, insulated flange, wire size #12-10 for #8 stud.|||||||||||
* 75°C or higher.
** Spade terminal, 30A max, insulated flange, wire size #12-10 for #8 stud.
## **Specifications**
## **Agency Information**
- CE Compliant
- RoHS Compliant
- UL 98 Listed, File E302370, Guide WHTY
- cULus to CSA Standard 22.2 No. 4-04, File 302370, Guide WHTY7
## **Terminals**
- Single/dual conductor box lug or spade terminal suitable for line, load or accessory connection
- Torque: 0-60A: - #18-10 20Lb-In
- #8-4 35Lb-In
- 70-100A: - #18-10 Single 25Lb-In
- #8-2 Single 35Lb-In - #1 Single 40Lb-In - #6 Dual 45Lb-In
## **Mounting**
- 35mm DIN-Rail
## **Local Open Fuse Indication Minimum Voltage[†]**
- 90Vac/115Vdc
- Circuit must be closed for indication light to illuminate.
## **Features**
- Ampacity rejecting disconnects will not accept CUBEFuse amp ratings greater than switch rating
- IP20 Finger-safe construction with #10 or larger wire
- Switch interlock prohibits removing the fuse under load
## **Accessories**
- Auxiliary contacts
- PLC Wired remote fuse indication (up to 60A)
## **Fuses**
- Uses finger-safe Class CF CUBEFuse™ with Class J performance
- Low-Peak™ dual-element, time-delay*
- Non-indicating 1-100A
- Indicating 6-100A
- Fast-Acting** 1-100A
- See Data Sheet # 9000
- ** See Data sheet # 2147
## **Storage and Operating Temperature**
- -20ºC to 75ºC***
- *** For fuse performance under or above 25ºC, consult fuse performance derating charts
- in the Bussmann publication titled _Selecting Protective Devices_ (SPD) reorder #3002.
## **Flammability Rating UL 94V0**
## **Lockout/Tagout Provisions**
**==> picture [251 x 144] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lockout Provision Switch Handle<br>Circuit Open Fuse<br>Marking Area Indication Light<br>Ae<br>SI Z<br>Spade Terminal<br>Fuse Holder Box Lug<br>Terminal<br>**----- End of picture text -----**<br>
- 4mm shank lock or standard pin-out devices
## **Data Sheet: 1157**
**382**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **Compact Circuit Protector (CCP) Disconnect Switch—30, 60 & 100A 1-, 2- & 3-Pole, Class CF CUBEFuse™**
## **Dimensions – mm (in)**
30 and 60 Amp
100 Amp
**==> picture [317 x 433] intentionally omitted <==**
**----- Start of picture text -----**<br>
75.7<br>50.4 (3.0)<br>(2.0)<br>25.1<br>(1.0)<br>. ja) ja (aie<br>113.9 HH H=H 7.6 aE<br>(4.5) (0.3)<br>79.5<br>(3.0)<br>50.5<br>25.15 (2.0)<br>(1.0)<br>“ol ae ue<br>A] «HE<br>is — 22 147.1 ]<br>(5 8)<br>}1<br>.<br>‘ - ,<br>eo Ae. “i<br>=f 2 © le<br>if = = .<br>Auxiliary Contacts PLC Indicator<br>(Includes leads with spade terminals)<br>89.1 (3.5)<br>75.1 (3.0) 30A CUBEFuse 83.3 (3.3) 60A CUBEFuse 9.1 (0.4)<br>49.2 (1.9) 60.3 (2.4)<br>100.0 (3.9)<br>91.2 (3.6)<br>56.6 (2.2) 67.7 (2.7)<br>**----- End of picture text -----**<br>
## **CCP-_-_CF Accessories**
|**CCP-_-_CF Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|**CCP-_-_CF Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|**CCP-_-_CF Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|**CCP-_-_CF Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|**CCP-_-_CF Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|**CCP-_-_CF Accessories**<br>**Minimum**<br>**Signal**<br>**Circuit**<br>**Agency**<br>**Part**<br>**Description**<br>**Configuration**<br>**Output**<br>**Voltage**<br>**Information**<br>**Number**|
|---|---|---|---|---|---|
|Auxiliary Contacts NO+NC<br>for Switch Status up to 60A|1 per CCP<br>5A/240Vac|5A/240Vac|UL 98 Recognized,<br>–<br>cURus 22.2 No. 4-04,<br>IE|UL 98 Recognized,<br>cURus 22.2 No. 4-04,<br>IEC 60947-5-1 AC15|CCP-AUX*|
|Auxiliary Contacts NO+NC<br>forSwitchStatus70to100A|1 per CCP<br>5A/240Vac|5A/240Vac|–<br>UL 98 Recognized,|UL 98 Recognized,<br>CSAC22.2 No. 4|CCP-AUX-100*|
|Wired Remote Fuse Indication<br>for PLCApplications|1 per CCP|24Vdc|100Vac<br>UL 98 Recognized,<br>cU|UL 98 Recognized,<br>cURus22.2 No. 4-04|CCP-PLC-IND*|
|Wired Remote Fuse Indication<br>for PLC Applications upto 60A|1 per CCP<br>8A/24Vdc<br>to 60A|8A/24Vdc|100Vac<br>UL 98 Recognized,|UL 98 Recognized,<br>CSA C22.2 No. 4|CCP-PLC-100*|
|* Refer to Data Sheet # 1157 for details.||||||
**383**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **Compact Circuit Protector Base (CCPB) CUBEFuse[™]**
## **Specifications:**
- CCPB Ampacity rejection breaks: 15A, 20A, 30A, 40A, 50A, 60A, 70A, 90A and 100A.
- 1-, 2- and 3-Pole versions
- For systems 600Vac (or less)
- Box lug loadside terminal:
- 18-6AWG single & dual rated, solid or stranded – 75°C, Cu only
- 4AWG single – 75°C, Cu only
- Box lug loadside terminal torque: 18-10AWG 20 Lb-In
- (2.2 N•m), 8-4AWG 35 Lb-In (3.9 N•m)
The revolutionary Bussmann CCPB with CUBEFuse[™] is designed as a fused branch circuit disconnect with fuse holder for the Bussmann Quik-Spec™ Coordination Panelboard. The CCPB with CUBEFuse simplifies selective coordination and allows for isolation of individual branch circuit loads for safe work practices.
## **Product Features and Benefits**
- Uses finger-safe Class CF Low-Peak[™] CUBEFuse with current-limiting, time-delay Class J performance*
- High Short-Circuit Current Ratings at 200kA
- Spade terminal load connection:
- Max. 30A suitable for use with #8-32UNC screw
- Bolt-on style bus connector, #10-32-UNC Hex flange Phillips screw, torque to 25 Lb-In (2.8N•m)
- Lockout/tagout: 4mm shank lock
- Bolt-mounted design into Quik-Spec Coordination Panelboard bus
- Local indication: illumination requires closed circuit and minimum 90Vac operating voltage
- RoHS compliant
- Disconnect rated to provide means for load isolation
- Full voltage rated at 600Vac
- UL 98 Listed and suitable for branch circuit disconnect and branch circuit protection
- 1-, 2- and 3-pole versions are horsepower rated
- Patented rejection feature helps prevent overfusing
## **Agency Information:**
UL 98 Listed, File E302370, Guide WHTY
cULus to CSA Standard 22.2 No. 4, File E302370, Guide WHTY7
CE Compliant
- Complies with UL and cULus
- Open fuse indication light per pole
- Additional open fuse indication can be provided by using the indicating CUBEFuse version
- Built-in switch/fuse interlock prohibits removing the fuse while energized
- Permanent lockout/tagout provisions
**Shipping Weight:** 2.03 lbs per carton
**Carton quantity:** 6 poles
## **Environmental Data**
Storage and operating temperature: -20ºC to 75ºC**
- Lock-ON provision
- *See data sheet 9000 for CUBEFuse specifications.
- **For fuse performance under or above 25ºC, consult fuse performance derating charts.
**384**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **Compact Circuit Protector Base (CCPB) CUBEFuse[™]**
## **Technical Ratings**
**CUBEFuse™ (Class J performance) CCPB Part Poles[Voltage ][Time-Delay Time-Delay Fast-Acting][Max. Fuse**] SCCR Hp Ratings***[Numbers][Ratin][g][Non-Indicating Indicating* Non-Indicating][Ampacity]** CCPB-1-15CF 1 0.5Hp@120V CCPB-2-15CF 2 TCF1RN, TCF3RN, TCF6, TCF10, FCF1RN, FCF3RN, 1.5Hp@240V 600Vac TCF6RN, TCF10RN, TCF15 FCF6RN, FCF10RN, 15A 200kA 3Hp@240V CCPB-3-15CF 3 TCF15RN FCF15RN 5Hp@480V 7.5Hp@600V CCPB-1-20CF 1 0.75Hp@120V CCPB-2-20CF 2 2Hp@240V 600Vac[TCF17-1/2RN, ] TCF17-1/2, FCF20RN 20A 200kA 3Hp@240V CCPB-3-20CF 3[TCF20RN] TCF20 7.5Hp@480V 10Hp@600V CCPB-1-30CF 1 1.5Hp@120V CCPB-2-30CF 2 3Hp@240V 600Vac[TCF25RN,] TCF25, TCF30 FCF25RN, 30A 200kA 5Hp@240V CCPB-3-30CF 3[TCF30RN] FCF30RN 15Hp@480V 10Hp@600V CCPB-1-40CF 1 2.0Hp@120V CCPB-2-40CF 2 3Hp@240V 600Vac[TCF35RN,] TCF35, TCF40 FCF35RN, 40A 200kA 7.5Hp@240V CCPB-3-40CF 3[TCF40RN] FCF40RN 20Hp@480V 10Hp@600V CCPB-1-50CF 1 3.0Hp@120V CCPB-2-50CF 2 5Hp@240V 600Vac[TCF45RN,] TCF45, TCF50 FCF45RN, 50A 200kA 7.5Hp@240V CCPB-3-50CF 3[TCF50RN] FCF50RN 20Hp@480V 10Hp@600V CCPB-1-60CF 1 3.0Hp@120V CCPB-2-60CF 2 7.5Hp@240V 600Vac TCF60RN TCF60 FCF60RN 60A 200kA 7.5Hp@240V CCPB-3-60CF 3 20Hp@480V 10Hp@600V CCPB-1-70CF 1 3.0Hp@120V CCPB-2-70CF 2 7.5Hp@240V 600Vac TCF70RN TCF70 FCF70RN 70A 200kA 15Hp@240V CCPB-3-70CF 3 30Hp@480V CCPB-1-90CF 1 5.0Hp@120V CCPB-2-90CF 2 FCF80RN, 10Hp@240V 600Vac TCF90RN TCF90 FCF90RN 90A 200kA 20Hp@240V CCPB-3-90CF 3 40Hp@480V CCPB-1-100CF 1 5.0Hp@120V CCPB-2-100CF 2 10Hp@240V 600Vac TCF100RN TCF100 FCF100RN 100A 200kA 20Hp@240V CCPB-3-100CF 3 50Hp@480V
- *1A and 3A indicating CUBEFuse not available. Correct fit with CCPB disconnect requires indicating CUBEFuse with date code R38 or later.
- **Any fuse with an amp rating less than or equal to the max fuse rating may be used.Example: TCF15 may be used with CCPB-1-20CF.
- ***Do not use UPS/Critical Application fast-acting CF with motors.
**385**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—30 to 800A**
## **Description**
Bussmann UL 98 and UL 489 fused disconnect switches “break” and “make” power circuits ON and OFF load.
The switches employ double break contacts per pole that help ensure complete isolation of the fuse when the switch is in the "OFF" position.
## **Features**
- Make and break power under load
- Double break by pole
- DIN-Rail or panel mount (30-100A)
- Up to 200kA Short-Circuit Current Rating
- Finger-safe covers
- Compact footprints available
- Defeatable handles automatically re-latch when the panel door is closed
- Most disconnect switches are front, right side, flange or direct handle operable
- NFPA 79 Compliant handle kits
## **Agency Information**
- UL 98, Guide WHTY, File E155130
- UL 489, Guide WJAZ, File E359801
- CSA 22.2 No. 4, File 257020
- Conforms with IEC 60947-3
- NFPA 79 (2002 Edition)
## **Online Resources**
Visit www.cooperbussmann.com/Disconnects for:
- CAD Drawings
- Instruction Sheets
- UL Information
QuikShip Everyday Service ships the most common part numbers within 24 hours. Contact your Bussmann representative for details.
|**Available Bussmann Fuses**|**Available Bussmann Fuses**||
|---|---|---|
|**Class **|**Type**|**Data Sheet #**|
|CC|LP-CC Time-Delay, Current Limiting|1023|
|CC|FNQ-R Time-Delay|1014|
|CC|KTK-R Fast-Acting|1015|
|J|LPJ Time-Delay, Current Limiting|1006 (0-60A)|
|J||1007 (70-600A)|
|J|With_easy_ID™ open fuse indication|1062 (6-60A)|
|J||1063 (70-600A)|
|J|JKS Fast-Acting Fuses|1026 (0-60A)|
|J||1027 (70-600A)|
|J|DFJ High Speed Drive Fuse|1048 (0-600A)|
|L|KRP-C Time-Delay, Current Limiting|1008|
|L|KTU Fast-Acting|1010|
|L|KLU Time-Delay|1013|
**386**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—30 to 800A**
## **Specifications**
||St:in<br>-<br>be|in|©ie|©ie|1||Lg<br>P>,|Lg|eat)|eat)||
|---|---|---|---|---|---|---|---|---|---|---|---|
||**RDF30CC-3**||**RDF30J-3 / RDF60J-3-COMP**||**RDF60J-3**||P >,|**RDF200J-3**|**RDF600J-3**|||
|**Part Number**||||||||||||
|**2-Pole**|**—**|**—**|**RDF30J-2**|**RDF60J-2-COMP**|**RDF60J-2**|**RDF100J-2**|**RDF200J-2**|**RDF400J-2**|**RDF600J-2**|**RDF800L-2**||
|**3-Pole**|**RDF30CC-3**|**RDF30J-3-COMP**|**RDF30J-3**|**RDF60J-3-COMP**|**RDF60J-3**|**RDF100J-3**|**RDF200J-3**|**RDF400J-3**|**RDF600J-3**|**RDF800L-3**||
|**3-Pole + Neutral**|**RDF30CC-3N**|**RDF30J-3N-COMP**|**—**|**—**|**—**|**—**|**—**|**—**|**—**||**—**|
|**4-Pole**|**—**|**—**|**RDF30J-4**|**RDF60J-4-COMP**|**RDF60J-4**|**RDF100J-4**|**RDF200J-4**|**RDF400J-4**|**RDF600J-4**|**RDF800L-4**||
|UL Standard|UL 489|UL 489|UL 98|UL 98|UL 98|UL 98|UL 98|UL 98|UL 98||UL 98|
|Fuse Class|CC|J|J|J|J|J|J|J|J||L|
|Max Fuse/Ampacity|30|30|30|60|60|100|200|400|600||800|
|Switch Type|Compact|Compact|Standard|Compact|Standard|Standard|Standard|Standard|Standard|Standard||
|Handle Operation|Front|Front|Front/Side|Front/Side|Front/Side|Front/Side|Front/Side|Front/Side|Front||Front|
||||Flange|Flange|Flange|Flange|Flange|||||
|**UL Electrical Ratings**||||||||||||
|Max AC Volts|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac||600Vac|
|Max DC Volts*|—|—|250Vdc|250Vdc|250Vdc|250Vdc|—|250Vdc|600Vdc||600Vdc|
|Std AC Horsepower Ratings||||||||||||
|1-Phase, 240Vac<br>3-Phase, 240Vac<br>3-Phase, 480Vac<br>3-Phase, 600Vac<br>Max AC Horsepower Ratings|—<br>3<br>5.0<br>7.5|—<br>3<br>5.0<br>7.5|3<br>3<br>5.0<br>7.5|10<br>7.5<br>15<br>15|10<br>7.5<br>15<br>15|10<br>15<br>25<br>30|10<br>25<br>50<br>60|10<br>50<br>100<br>125|—<br>75<br>150<br>200||—<br>75<br>200<br>250|
|3-Phase, 240Vac|7.5|7.5|7.5|15|15|30|60|125|200||200|
|3-Phase, 480Vac|15|15|15|30|30|60|125|250|400||500|
|3-Phase, 600Vac|20|20|20|50|50|75|150|350|500||500|
|DC Horsepower Ratings||||||||||||
|125Vdc|—|—|3|5|5|7.5|—|20|—||—|
|250Vdc|—|—|5|10|10|20|—|50|—||—|
|**Electrical Characteristics**||||||||||||
|SCCR|100kA|100kA|200kA|100kA|200kA|200kA|200kA|200kA|200kA||200kA|
|Terminal Lugs/Kits|Integral|Integral|Integral|Integral|Integral|Integral|•|•|•||•|
|Mounting Torque - Lb-In (N•m)|—|—|—|—|—|—|160 (18)|310 (35)|310 (35)||310 (35)|
|Wire Type|75°C Cu|75°C Cu|75°C Cu|75°C Cu|75°C Cu|75°C Cu|75°C Cu/Al|75°C Cu/Al|75°C Cu/Al|75°C Cu/Al||
|Wire Range &||||||||||||
|Torque - Lb-In (N•m)||||||||||||
|Solid|#14-10|#14-10|#14-10|#14-10|#12-10|#12-10|—|—|—||—|
||27 (3.1)|27 (3.1)|31 (3.5)|31 (3.5)|35.4 (4)|35.4 (4)|—|—|—||—|
|Stranded|#14-10|#14-10|#14-6|#14-6|#12-1|#12-1|#6-300MCM|#4-600MCM|(2) #2-600MCM|(2) #2-600MCM|(2) #2-600MCM|
||27 (3.1)|27 (3.1)|31 (3.5)|31 (3.5)|35.4 (4)|35.4 (4)|275 (31)|550 (62)|375 (42.4)|375 (42.4)||
|||||||||Dual 1/0-250MCM||||
|||||||||550(62)||||
|**Mechanical Characteristics**||||||||||||
|Endurances/Cycles|10,000|10,000|10,000|10,000|10,000|10,000|8000|6000|5000||5000|
|**Physical Characteristics**||||||||||||
|Dimensions||||||||||||
|See drawings on||||||||||||
|product pages||||||||||||
|Weight - Lbs (KG)||||||||||||
|2-Pole|—|—|3.0 (1.3)|3.1 (1.4)|4.0 (1.8)|4.07 (1.8)|5.7 (2.6)|11.4 (5.2)|31.7 (14.4)|31.7 (14.4)||
|3-Pole|1.3 (0.6)|1.4 (0.6)|3.8 (1.7)|4.1 (1.8)|5.3 (2.4)|5.3 (2.4)|7.8 (3.5)|16.6 (7.6)|44.2 (20.1)|44.2 (20.1)||
|3-Pole + Neutral|1.4 (0.6)|1.5 (0.7)|—|—|—|—|—|—|—||—|
|4-Pole|—|—|4.7(2.1)|4.8(2.2)|X.X(2.9)|6.49(2.9)|10.8(4.9)|21.8(9.9)|56.8(25.8)|56.8(25.8)||
|**Environmental**||||||||||||
|Operating Temp. Range|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C||
|FlammabilityRating|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0||
|**Accessories**||||||||||||
|Lug Kit|Integral|Integral|Integral|Integral|Integral|Integral|•|•|•||•|
|Handles<br>Direct|•|•|•|•|•|•|•|•|•||•|
|Front Selector|•|•|—|—|—|—|—|—|—||—|
|Front Pistol|•|•|•|•|•|•|•|•|•||•|
|Side Pistol|—|—|•|•|•|•|•|•|—||—|
|Flange||||||||||||
|Cable|—|—|•|•|•|•|•|—|—||—|
|Shaft|—|—|•|•|•|•|•|—|—||—|
|NFPA Through Door Handle|•|•|•|•|•|•|•|•|•||•|
|Shafts c/s - mm|5x5|5x5|10x10|10x10|10x10|10x10|10x10|10x10|12X12||12X12|
|Terminal Shrouds|Not Required|Not Required|Not Required|Not Required|Not Required|Not Required|•|•|•||•|
|Auxiliary Contacts||||||||||||
|(1) NO|•|•|•|•|•|•|•|•|•||•|
|(1) NC|•|•|•|•|•|•|•|•|•||•|
|AC Ratings||||||||||||
|Volts|600|600|600|600|600|600|600|600|600||600|
|Amps|10|10|10|10|10|10|10|10|10||10|
|• Available, see product page for details and part numbers.||||||||||||
|— Not available.||||||||||||
|* General purpose only, not photovoltaic rated.||||||||||||
**387**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—30A Compact Class CC & Class J**
**For a Complete Assembly, Please Select:**
**Switch Max Horsepower Rating, 3-Ph Amp Fuse Number 220/ 440/ 600 Wire Wire Part Rating Class of Poles SCCR 240Vac 480Vac Vac Size Type Number** 30 CC 3 100kA 7.5 15 20 #14-10 Sol/Str 75°C Cu RDF30CC-3 30 CC 3 + Ntrl* 100kA 7.5 15 20 #14-10 Sol/Str 75°C Cu RDF30CC-3N 30 J 3 100kA 7.5 15 20 #14-10 Sol/Str 75°C Cu RDF30J-3-COMP 30 J 3 + Ntrl* 100kA 7.5 15 20 #14-10 Sol/Str 75°C Cu RDF30J-3N-COMP * Neutral is switched. ~~EE~~ **+ Direct Mount Handle -** mounts directly to switch, no shaft required **For Switch Test Part Part Number Color Function Padlockable Number** RDF30CC-_ Black Y Y DIR-05 RDF30J-_-COMP Black Y Y DIR-06 ~~——————E~~ or **External Front Operated Selector Handle -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 4, 4X, 12 Black N Y Y H4X-04B 1, 3R, 4, 4X, 12 Red/Yellow N Y Y H4X-04R S + ~~ee ee ee~~ **Shafts for Selector Handles Length Mounting Depth Part in (mm) (X) in (mm) Number** 7.9 (200) 4.02~9.65 (102~245) SH1-200 12.6 (320) 4.02~14.37 (102~365) SH1-320 15.7 (400) 4.02~17.52 (102~445) X SH1-400 4 ~~ee ee~~ or ~~—~~ **External Front Operated Pistol Handles -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 12 Black N Y Y H12-05B 1, 3R, 12 Red/Yellow N Y Y H12-05R 1, 3R, 4, 4X, 12 Black N Y Y H4X-05B 1, 3R, 4, 4X, 12 Red/Yellow N Y Y H4X-05R or 11,, 3R3R,, 4 4,, 4X 4X,, 12 12 Red/YellowBlack YY YY YY H4X-H4X-05TR05TB **Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles** - shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 4, 4X, 12 Black N Y Y H4X-05BHD 1, 3R, 4, 4X, 12 Red/Yellow N Y Y H4X-05RHD **Shafts for Pistol Handles** + **Length Mounting Depth Part in (mm) (X) in (mm) Number** 7.9 (200) 4.02~9.65 (102~245) SH2-200 12.6 (320) 4.02~14.37 (102~365) SH2-320 ~~—FE~~ 15.7 (400) 4.02~17.52 (102~445) X SH2-400 or **NFPA Through the Door Handle Kit** - to be used with selector handle or front pistol handle **Test Part Color Function Padlockable Defeatable Number** Red N Y N H79-1 ~~SEE~~ and… **Auxillary Contacts** (1) **Contact Number of Continuous Voltage Maximum Number of Auxiliary Contacts Part Type Contacts Amp Rating Rating per Disconnect Switch Part Number Number** NO 1 10A 600Vac RDF30CC-_: 4 / 8 with BAC-HOLDER2 BAC05[(1)] NC 1 10A 600Vac RDF30J-_-COMP: 2 /6 with BAC-HOLDER2 BAC06[(1)] Auxillary Accepts 4 Auxillary Contacts: Contact BAC-HOLDER2[(2)] (2) BAC05 or BAC06 Holder ~~cc~~
**388**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—30A Compact Class CC & Class J**
**==> picture [518 x 321] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – in (mm) 3.28 3.78<br>• RDF30CC-_ 83.3 1.12 96 1.47 0.59<br>28.5 37.5 15<br>5.19 (131.8)<br>Fuse Cover Fully Open<br>•RDF30J-_-COMP 3.89 4.13<br>99 105<br>1.12 1.47 0.59<br>28.5 37.5 15<br>1<br>25.5<br>4.56 116<br>3.3 84<br>1<br>25.5<br>4.56 116<br>3.3 84<br>**----- End of picture text -----**<br>
## **External Front Selector Handle**
**==> picture [458 x 236] intentionally omitted <==**
**----- Start of picture text -----**<br>
Selector Handle Type Direction of Front Operation Door Drilling Layout<br>1.57<br>I 40<br>0.11<br>Ø3.07 4 Ø 0.27 3<br>Ø78 4 Ø 7<br>0<br>H4X-04_ 1.4537 Ø 1.22Ø 31 With 4 Mounting Screws Ø Ø 22.50.88 With Mounting Nut<br>External Front Pistol Handles<br>Pistol Handle Type Direction of Front Operation Door Drilling Layout<br>I<br>Ø 1.46<br>Ø3.07 4 Ø 0.27 Ø 37<br>Ø78 4 Ø 7<br>0<br>H4X-05__ 1.73<br>H12-05__ 44<br>TEST 0.55 0.55<br>14 14<br>90°<br>90°<br>3.46 88 1.10 28 0.53 13.5<br>0.78 20<br>2.75 70<br>65° 0.78 20<br>**----- End of picture text -----**<br>
**389**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—30A Standard Class J**
## **For a Complete Assembly, Please Select:**
**Switch Max Horsepower Rating 1-Phase 3-Phase DC* Amp Fuse No. of 220/ 220/ 440/ 600 125 250 Wire Wire Part Rating Class Poles SCCR 240Vac 240Vac 480Vac Vac Vdc Vdc Size Type Number** 30 J 2 200kA 3 - - - 3 5 #14-10 Sol 75°C Cu RDF30J-2 #14-6 Str 30 J 3 200kA - 7.5 15 20 3 5 #14-10 Sol 75°C Cu RDF30J-3 #14-6 Str 30 J 4 200kA - 7.5 15 20 3 5 #14-10 Sol 75°C Cu RDF30J-4 #14-6 Str ~~VEE~~ ee ~~ee~~ * DC Ratings use two poles in series. **+ Direct Mount Handle -** mounts directly to switch, no shaft required **For Switch Test Part Part Number Color Function Padlockable Number** All Switches Black Y Y - On Switch DIR-07 ~~FO~~ or **External Front Operated Pistol Handles -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 12 Black N Y Y H12-05B 1, 3R, 12 Red/Yellow N Y Y H12-05R 1, 3R, 4, 4X, 12 Black N Y Y H4X-05B 1, 3R, 4, 4X, 12 Red/Yellow N Y Y H4X-05R 1, 3R, 4, 4X, 12 Black Y Y Y H4X-05TB or 1, 3R, 4, 4X, 12 Red/Yellow Y Y Y H4X-05TR **Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 4, 4X, 12 Black N Y Y H4X-05BHD 1, 3R, 4, 4X, 12 Red/Yellow N Y Y H4X-05RHD **External Right Side Operated Pistol Handles -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 4, 4X, 12 Black N Y N/A H4X-05SB 1, 3R, 4, 4X, 12 Red/Yellow N Y N/A H4X-05SR + **Shafts for Pistol Handles Length Mounting Depth Part in (mm) (X) in (mm) Number** 7.9 (200) 5.30~9.06 (135~230) SH5-200 12.6 (320) 5.30~13.78 (135~350) SH5-320 ~~f-===~~ 15.7 (400) 5.30~16.93 (135~430) X SH5-400 or (1) **Flange Handle**[(1) ] - requires shaft operated mechanism or cable operated mechanism + cable **NEMA Flange Test Part** (2) **Type Style Function Padlockable Defeatable Number** 1, 3R, 4, 12 Standard N Y Y FLH1 1, 3R, 4, 4X, 12 Chrome Plated N Y Y FLH2 **Shaft Operated Flange Mechanism**[(2)] - includes shaft **For Enclosure Part Depth - in (mm) Number** 6~24 (152~613) FLRM (3) **Cable Operated Flange Mechanism and Cable** - must select Mechanism[(3)] _and_ Cable[(4)] **Part** ie ~~ee ee ee~~ **Item / Length Number** Cable Mechanism FLCM (4) 36” (900mm) Cable FLC36 60” (1500mm) Cable FLC60 120” (3000mm) Cable FLC120 or **NFPA Through the Door Handle Kit** - to be used with selector handle or front pistol handle **Test Part Color Function Padlockable Defeatable Number** Red N Y N H79-2 ~~Sa~~
**390**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—30A**
## **Standard Class J**
**==> picture [522 x 587] intentionally omitted <==**
**----- Start of picture text -----**<br>
and …<br>Auxillary Contacts<br>Contact Number of Continuous Voltage Max Number of Aux Part<br>Type Contacts Amp Rating Rating Contacts per Switch Number<br>NO 1 10A 600Vac 4 BAC05<br>NC 1 10A 600Vac 4 BAC06<br>Boa e<br>Dimensions – in (mm)<br>5.87<br>149.3 4.84<br>1.41 1.46 1.41 123<br>N er al pal 36 ate 37.2 a 36<br>WSUS U N OS Vipers —<br>Pe —a-|<br>0000 | 0000 | 0000 | O i f<br>0000 | ooo0 | oooo JOT \<br>ggg | gags | goss a | | |) D ° |<br>0000 | 0000 | 0000 Y O I<br>000S58 0 | 0000Boas | 00S9 0 50 & © p ( |<br>0000 | 0000 | 0000 fF-__7 Oo \<br>A 0 00 0 | 0 00 0 | 0 00 0 a ( On al<br>Terror or | i<br>tele a<br>Direct Mount Handle Flange Handle<br>1.57 1.79 3.50<br>40 45.5 (88.9) Ø0.28<br>2.16 (Ø7.1)<br>(54.9) Ø0.50 1.55<br>0.86 1.06 (Ø12.7) (39.4)<br>(26.9)<br>(21.8)<br>4.68<br>5.66 1.00 (118.9)<br>6.22 (143.8) (25.4)<br>(158.0)<br>1.00 0.88<br>\ H (25.4) (22.3)<br>DIR-07 Nee<br>Ly<br>2.32<br>7.10 (58.9) 2.70<br>(180.3) (68.6)<br>FLH_<br>External Front & Right Side Pistol Handle<br>Handle Type Direction of Front Operation Direction of Right Side Operation Door Drilling Layout<br>I<br>I<br>Ø3.07 ar hI! s 4 Ø 0.27 Ø 1.46Ø 37<br>Ø78 4 Ø 7<br>0<br>0<br><O) Ca<br>H4X-05__ 1.73<br>H12-05__ 44<br>TEST 0.55 all 0.55<br>14 14<br>90°<br>90°<br>ONTACTS<br>Acc. C<br>UX<br>A<br>2.68 68.07<br>5.35 136 4.02 102.1<br>5.31 135<br>0.78 20<br>2.75 70<br>65° 0.78 20<br>**----- End of picture text -----**<br>
**391**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
**For a Complete Assembly, Please Select:**
## **UL 98 Fused Rotary Disconnect Switches—60A Compact Class J**
**Switch Max Horsepower Rating 1-Phase 3-Phase DC* Amp Fuse Number 220/ 220/ 440/ 600 125 250 Wire Wire Part Rating Class of Poles SCCR 240Vac 240Vac 480Vac Vac Vdc Vdc Size Type Number** 60 J 2 100kA 10 - - - 5 10 #14-10 Sol 75°C Cu RDF60J-2-COMP #14-6 Str 60 J 3 100kA - 15 30 50 5 10 #14-10 Sol 75°C Cu RDF60J-3-COMP #14-6 Str 60 J 4 100kA - 15 30 50 5 10 #14-10 Sol 75°C Cu RDF60J-4-COMP ~~a~~ #14-6 Str ~~ee~~ * DC Ratings use two poles in series. **+ Direct Mount Handle -** mounts directly to switch, no shaft required **For Switch Test Part Part Number Color Function Padlockable Number** All Switches Black Y Y - On Switch DIR-07 fF ~~Ee~~ or **External Front Operated Pistol Handles -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 12 Black N Y Y H12-05B 1, 3R, 12 Red/Yellow N Y Y H12-05R 1, 3R, 4, 4X, 12 Black N Y Y H4X-05B 1, 3R, 4, 4X, 12 Red/Yellow N Y Y H4X-05R 1, 3R, 4, 4X, 12 Black Y Y Y H4X-05TB or 1, 3R, 4, 4X, 12 Red/Yellow Y Y Y H4X-05TR **Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 4, 4X, 12 Black N Y Y H4X-05BHD 1, 3R, 4, 4X, 12 Red/Yellow N Y Y H4X-05RHD **External Right Side Operated Pistol Handles -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 4, 4X, 12 Black N Y N/A H4X-05SB 1, 3R, 4, 4X, 12 Red/Yellow N Y N/A H4X-05SR + **Shafts for Pistol Handles Length Mounting Depth Part in (mm) (X) in (mm) Number** 7.9 (200) 5.30~9.06 (135~230) SH5-200 12.6 (320) 5.30~13.78 (135~350) SH5-320 15.7 (400) 5.30~16.93 (135~430) X SH5-400 ~~B=====~~ or (1) **Flange Handle**[(1) ] - requires shaft operated mechanism or cable operated mechanism + cable **NEMA Flange Test Part Type Style Function Padlockable Defeatable Number** (2) 1, 3R, 4, 12 Standard N Y Y FLH1 1, 3R, 4, 4X, 12 Chrome Plated N Y Y FLH2 **Shaft Operated Flange Mechanism**[(2)] - includes shaft **For Enclosure Part Depth - in (mm) Number** 6~24 (152~613) FLRM (3) **Cable Operated Flange Mechanism and Cable** - must select Mechanism[(3)] _and_ Cable[(4)] **Part Item / Length Number** Cable Mechanism FLCM (4) 36” (900mm) Cable FLC36 60” (1500mm) Cable FLC60 120” (3000mm) Cable FLC120 or **NFPA Through the Door Handle Kit** - to be used with selector handle or front pistol handle **Test Part Color Function Padlockable Defeatable Number** Red N Y N H79-2 ~~Ss eee~~
**392**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—60A**
## **Compact Class J**
**==> picture [486 x 587] intentionally omitted <==**
**----- Start of picture text -----**<br>
and …<br>Auxillary Contacts<br>Contact Number of Continuous Voltage Max Number of Aux Part<br>Type Contacts Amp Rating Rating Contacts per Switch Number<br>NO 1 10A 600Vac 4 BAC05<br>NC 1 10A 600Vac 4 BAC06<br>Bsa a<br>Dimensions – in (mm)<br>5.87<br>149.3 4.84<br>1.41 1.46 1.41 123<br>36 37.2 36<br>a(peuvan| l epupipe ll ’s deren a—So<br>0000 a == |<br>0000 | 0000 | 0000 | O i f<br>gpeg| | oooo | oooo J OT \<br>Bee|| Gees | ess, 4 | |) P ° |<br>00000000 [|] [0000] Bee [|] [0000] [Eee o&© © | O 4:<br>0000 | 0000 | 0000 (<br>e_QOoe | 0000 | 0000 |-—_ Oo (<br>0 00 0 | 0 00 0 a i ! On ali<br>Tort Oonzon |<br>ne A<br>Direct Mount Handle Flange Handle<br>1.57 1.79 3.50<br>40 45.5 (88.9) Ø0.28<br>2.16 (Ø7.1)<br>(54.9) Ø0.50 1.55<br>vA ‘ 4 0.86 (26.9)1.06 (Ø12.7) (39.4)<br>(21.8)<br>4.68<br>5.66 1.00 (118.9)<br>ee 6.22 e (143.8) (25.4) a nes<br>(158.0)<br>1.00 0.88<br>\. = (25.4) (22.3)<br>DIR-07 Nog<br>oy<br>2.32<br>7.10 (58.9) 2.70<br>(180.3) (68.6)<br>FLH_<br>External Front & Right Side Pistol Handle<br>Handle Type Direction of Front Operation Direction of Right Side Operation Door Drilling Layout<br>I<br>I<br>Ø3.07 > h1! s 4 Ø 0.27 Ø 1.46Ø 37<br>Ø78 “/ I 4 Ø 7<br>0<br>0<br>< 9 Cuan<br>H4X-05__ 1.73<br>H12-05__ 44<br>TEST 0.55 M 0.55<br>14 14<br>90°<br>90°<br>ONTACTS<br>Acc. C<br>UX<br>A<br>2.68 68.07<br>5.35 136 4.02 102.1<br>5.31 135<br>0.78 20<br>2.75 70<br>65° 0.78 20<br>**----- End of picture text -----**<br>
**393**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
**For a Complete Assembly, Please Select:**
## **UL 98 Fused Rotary Disconnect Switches—60A Standard Class J**
|~~Fo~~|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~Fo~~|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~Fo~~|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~Fo~~|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~Fo~~|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~Fo~~|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~Fo~~|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~Fo~~|
|---|---|---|---|---|---|---|---|
||All Switches<br>~~Fo~~|Black|Y||Y||DIR-07|
|or||||||||
|+<br>or<br>~~Be~~<br>? <br>~~a~~|**External Front Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~Be~~|||||||
||1, 3R,12<br>~~Be~~|Black<br>~~Be~~|N<br>~~Be~~||Y<br>~~Be~~|Y<br>~~Be~~|H12-03B<br>~~Be~~|
||1, 3R,12<br>~~Be~~|Red/Yellow<br>~~Be~~|N<br>~~Be~~||Y<br>~~Be~~|Y<br>~~Be~~|H12-03R<br>~~Be~~|
||1, 3R,4,4X,12<br>~~Be~~|Black<br>~~Be~~|N<br>~~Be~~||Y<br>~~Be~~|Y<br>~~Be~~|H4X-06B<br>~~Be~~|
||1, 3R,4,4X,12<br>~~Be~~|Red/Yellow<br>~~Be~~|N<br>~~Be~~||Y<br>~~Be~~|Y<br>~~Be~~|H4X-06R<br>~~Be~~|
||1, 3R,4,4X,12<br>~~Be~~|Black<br>~~Be~~|Y<br>~~Be~~||Y<br>~~Be~~|Y<br>~~Be~~|H4X-06TB<br>~~Be~~|
||1,3R,4,4X,12|Red/Yellow|Y||Y|Y|H4X-06TR|
||**Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~ae~~|||||||
||1, 3R,4,4X,12<br>~~ae~~|Black<br>~~ae~~|N<br>~~ae~~||Y<br>~~ae~~|Y<br>~~ae~~|H4X-06BHD<br>~~ae~~|
||1,3R,4,4X,12<br>~~ae~~|Red/Yellow<br>~~ae~~|N<br>~~ae~~||Y<br>~~ae~~|Y<br>~~ae~~|H4X-06RHD<br>~~ae~~|
||**External Right Side Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br> ~~ae~~|||||||
||1, 3R,4,4X,12|Black|N||Y|N/A|H4X-06SB|
||1,3R,4,4X,12|Red/Yellow|N||Y|N/A|H4X-06SR|
||**Shafts for Pistol Handles**<br>**Length**<br>**Mounting Depth**<br>**Part**<br>**in(mm)**<br>**(X) in(mm)**<br>**Number**<br>~~a~~|||||||
||7.9 (200)<br>~~a~~|5.30~9.06 (135~230)<br>~~a~~|X<br>~~a~~|~~a~~|||SH5-200<br>~~a~~|
||12.6 (320)<br>~~a~~|5.30~13.78 (135~350)<br>~~a~~|||||SH5-320<br>~~a~~|
||15.7 (400)<br>~~a~~|5.30~16.93 (135~430)<br>~~a~~|||||SH5-400<br>~~a~~|
|or<br>~~a~~||||||||
|(1)<br>(2)<br>(3)<br>(4)<br>ie|**Flange Handle**(1)- requires shaft operated mechanism or cable operated mechanism + cable<br>**NEMA**<br>**Flange**<br>**Test**<br>**Part**<br>**Type**<br>**Style**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~a~~|||||||
||1, 3R,4,12<br>~~a~~|Standard<br>~~a~~|N<br>~~a~~||Y<br>~~a~~|Y|FLH1|
||1,3R,4,4X,12<br>~~a~~|Chrome Plated<br>~~a~~|N<br>~~a~~||Y<br>~~a~~|Y|FLH2|
||**Shaft Operated Flange Mechanism**(2) - includes shaft<br>**For Enclosure Depth**<br>**Part**<br>**in(mm)**<br>**Number**<br>~~a~~|||||||
||6~24(152~613)<br>~~a~~|~~a~~|||||FLRM|
||**Cable Operated Flange Mechanism and Cable** - must select Mechanism(3) _and_<br>Cable(4)<br>**Part**<br>**Item / Length**<br>**Number**<br>~~a~~|||||||
||CableMechanism||||||FLCM|
||36”(900mm) Cable||||||FLC36|
||60”(1500mm) Cable||||||FLC60|
||120” (3000mm) Cable||||||FLC120|
**394**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—60A Standard Class J**
**==> picture [522 x 598] intentionally omitted <==**
**----- Start of picture text -----**<br>
or<br>NFPA Through the Door Handle Kit - to be used with front pistol handle<br>Test Part<br>Color Function Padlockable Defeatable Number<br>SMe Red N Y N H79-2<br>a es<br>and …<br>Auxillary Contacts<br>Contact Number of Continuous Voltage Max Number of Aux Part<br>Type Contacts Amp Rating Rating Contacts per Switch Number<br>NO 1 10A 600Vac 4 BAC05<br>NC 1 10A 600Vac 4 BAC06<br>Ca es—Oes es<br>Dimensions – in (mm) 5.87 4.81<br>149.3 1.41 122.2<br>1.41 1.46 36<br>36 37.2<br>l ew li ve lin e l | —<br>A 0000oooo | 0000oooo | 0000cooo Ele b O<br>sae 0000 | PRB 0000 || se 0000 oey | © {O |<br>0000 0000 0000 |__T (e)<br>A 0000oooo | 00000000 | 00000000 LE] O f<br>Lal GT i<br>Direct Mount Handle Flange Handle<br>1.57 1.79 3.50<br>40 45.5 (88.9) Ø0.28<br>2.16 (Ø7.1)<br>(54.9) Ø0.50 1.55<br>vA \ A 0.86 (26.9)1.06 (Ø12.7) (39.4)<br>(21.8)<br>4.68<br>5.66 1.00 (118.9)<br>6.22 (143.8) (25.4)<br>| (158.0) i s td |<br>1.00 0.88<br>\. | (25.4) (22.3)<br>DIR-07 \, d—f<br>Cy)<br>2.32<br>7.10 (58.9) 2.70<br>(180.3) (68.6)<br>FLH_<br>External Front and Right Side Pistol Handle<br>Handle Type Direction of Front Operation Direction of Right Side Operation Door Drilling Layout<br>I<br>I<br>Ø3.07<br>Ø 1.46<br>Ø78<br>4 Ø 0.27 Ø 37<br>4 Ø 7<br>we Wt e) ©<br>< g 0 yd<br>H4X-06__<br>1.77<br>H12-03__ 45 TEST 0.55 “fl 0.55<br>14 14<br>90°<br>90°<br>ANDLE<br>Select<br>NFPA H<br>ONTACTS<br>Acc. C<br>UX<br>A<br>3.66 92.96<br>7.32 186 6.77 172 5.23 133<br>5.31 135<br>0.78 20<br>4.92 125 0<br>65° 0.78 20<br>**----- End of picture text -----**<br>
**395**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
**For a Complete Assembly, Please Select:**
## **UL 98 Fused Rotary Disconnect Switches—100A Standard Class J**
|[~~Peeeeessreeee~~<br>a|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|**Switch**<br>**Max Horsepower Rating**<br>**1-Phase**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Size**<br>**Type**<br>**Number**<br>~~Peeeeessreeee~~|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||100<br>~~Peeeeessreeee~~|J<br>~~Peeeeessreeee~~|2<br>~~Peeeeessreeee~~||200kA<br>~~Peeeeessreeee~~|10<br>~~Peeeeessreeee~~|-<br>~~Peeeeessreeee~~||-<br>~~Peeeeessreeee~~|-<br>~~Peeeeessreeee~~||7.5<br>~~Peeeeessreeee~~|20<br>~~Peeeeessreeee~~|#12-10 Sol <br>#12-1Str<br>~~Peeeeessreeee~~||75°C Cu<br>~~Peeeeessreeee~~|RDF100J-2<br>~~Peeeeessreeee~~|
||100<br>~~Peeeeessreeee~~|J<br>~~Peeeeessreeee~~|3<br>~~Peeeeessreeee~~||200kA<br>~~Peeeeessreeee~~|-<br>~~Peeeeessreeee~~|30<br>~~Peeeeessreeee~~||60<br>~~Peeeeessreeee~~|75<br>~~Peeeeessreeee~~||7.5<br>~~Peeeeessreeee~~|20<br>~~Peeeeessreeee~~|#12-10 Sol <br>#12-1Str<br>~~Peeeeessreeee~~||75°C Cu<br>~~Peeeeessreeee~~|RDF100J-3<br>~~Peeeeessreeee~~|
||100<br>~~Peeeeessreeee~~|J<br>~~Peeeeessreeee~~|4<br>~~Peeeeessreeee~~||200kA<br>~~Peeeeessreeee~~|-<br>~~Peeeeessreeee~~|30<br>~~Peeeeessreeee~~||60<br>~~Peeeeessreeee~~|75<br>~~Peeeeessreeee~~||7.5<br>~~Peeeeessreeee~~|20<br>~~Peeeeessreeee~~|#12-10 Sol <br>#12-1 Str<br>~~Peeeeessreeee~~||75°C Cu<br>~~Peeeeessreeee~~|RDF100J-4<br>~~Peeeeessreeee~~|
||* DC Ratings use two poles in series.<br>~~Peeeeessreeee~~|||||||||||||||||
|**+**<br>[ ~~Peeeeessreeee~~<br>Of~~Ea~~||||||||||||||||||
|Of|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~Ea~~|||||||||||||||||
||All Switches<br>~~Ea~~|||Black<br>~~Ea~~||||Y<br>|||Y<br>||||||DIR-07<br>|
|or<br>Of ~~Ea~~||||||||||||||||||
|+<br>or<br>~~=~~<br>~~Se~~|**External Front Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>|||||||||||||||||
||1, 3R,12<br>~~=~~|||Black<br>~~=~~||||N<br>~~=~~|||Y<br>~~=~~||||Y<br>~~=~~||H12-03B<br>~~=~~|
||1, 3R,12<br>~~=~~|||Red/Yellow<br>~~=~~||||N<br>~~=~~|||Y<br>~~=~~||||Y<br>~~=~~||H12-03R<br>~~=~~|
||1, 3R,4,4X,12<br>~~=~~|||Black<br>~~=~~||||N<br>~~=~~|||Y<br>~~=~~||||Y<br>~~=~~||H4X-06B<br>~~=~~|
||1, 3R,4,4X,12<br>~~=~~|||Red/Yellow<br>~~=~~||||N<br>~~=~~|||Y<br>~~=~~||||Y<br>~~=~~||H4X-06R<br>~~=~~|
||1, 3R,4,4X,12<br>~~=~~|||Black<br>~~=~~||||Y<br>~~=~~|||Y<br>~~=~~||||Y<br>~~=~~||H4X-06TB<br>~~=~~|
||1,3R,4,4X,12<br>~~=~~|||Red/Yellow<br>~~=~~||||Y<br>~~=~~|||Y<br>~~=~~||||Y<br>~~=~~||H4X-06TR<br>~~=~~|
||**Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**|||||||||||||||||
||1, 3R,4,4X,12<br>~~a~~|||Black<br>~~a~~||||N<br>~~a~~|||Y<br>~~a~~||||Y<br>~~a~~||H4X-06BHD<br>~~a~~|
||1,3R,4,4X,12<br>~~a~~|||Red/Yellow<br>~~a~~||||N<br>~~a~~|||Y<br>~~a~~||||Y<br>~~a~~||H4X-06RHD<br>~~a~~|
||**External Right Side Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~a~~|||||||||||||||||
||1, 3R,4,4X,12|||Black||||N|||Y||||N/A||H4X-06SB|
||1,3R,4,4X,12|||Red/Yellow||||N|||Y||||N/A||H4X-06SR|
||**Shafts for Pistol Handles**<br>**Length**<br>**Mounting Depth**<br>**Part**<br>**in(mm)**<br>**(X) in(mm)**<br>**Number**<br>~~Se~~|||||||||||||||||
||7.9 (200)<br>~~Se~~|||5.30~9.06 (135~230)<br>~~Se~~||||X<br>~~Se~~||~~Se~~|||||||SH5-200<br>~~Se~~|
||12.6 (320)<br>~~Se~~|||5.30~13.78 (135~350)<br>~~Se~~|||||||||||||SH5-320<br>~~Se~~|
||15.7 (400)<br>~~Se~~|||5.30~16.93 (135~430)<br>~~Se~~|||||||||||||SH5-400<br>~~Se~~|
|or<br>~~Se~~||||||||||||||||||
|(1)<br>(2)<br>(3)<br>(4)<br>ay|**Flange Handle**(1)- requires shaft operated mechanism or cable operated mechanism + cable<br>**NEMA**<br>**Flange**<br>**Test**<br>**Part**<br>**Type**<br>**Style**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~——~~|||||||||||||||||
||1, 3R,4,12<br>~~——~~|||Standard||||N|||Y||||Y||FLH1|
||1,3R,4,4X,12<br>~~——~~|||Chrome Plated||||N|||Y||||Y||FLH2|
||**Shaft Operated Flange Mechanism**(2) - includes shaft<br>**For Enclosure Depth**<br>**Part**<br>**in(mm)**<br>**Number**<br>~~——~~|||||||||||||||||
||6~24(152~613)<br>~~——~~||||||||||||||||FLRM|
||**Cable Operated Flange Mechanism and Cable** - must select Mechanism(3) _and_<br>Cable(4)<br>**Part**<br>**Item / Length**<br>**Number**<br>~~——~~|||||||||||||||||
||CableMechanism<br>~~——~~||||||||||||||||FLCM|
||36”(900mm) Cable||||||||||||||||FLC36|
||60”(1500mm) Cable||||||||||||||||FLC60|
||120” (3000mm) Cable||||||||||||||||FLC120|
**396**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—100A Standard Class J**
**==> picture [520 x 594] intentionally omitted <==**
**----- Start of picture text -----**<br>
or<br>NFPA Through the Door Handle Kit - to be used with front pistol handle<br>Test Part<br>Color Function Padlockable Defeatable Number<br>Ne Red N Y N H79-2<br>Z a es ees es<br>and …<br>Auxillary Contacts<br>Contact Number of Continuous Voltage Max Number of Aux Part<br>Type Contacts Amp Rating Rating Contacts per Switch Number<br>NO 1 10A 600Vac 4 BAC05<br>NC 1 10A 600Vac 4 BAC06<br>CesGG—O<br>Dimensions – in (mm) 5.87 4.81<br>149.3 1.41 122.2<br>1.41 1.46 36<br>36 37.2<br>lalla! | —<br>| | | bare |<br>ooo00 | ooo00 | ooo0 b<br>0000 | 0000 | 0000 a M<br>f Ooo | Oooo | oooo Be O<br>eter) | leer || Gears ee P O<br>page 0000 | | goe8 0000 | 3535cooo0000 oFy | © |Oo<br>0000 | 0000 | 0000 |-—T} (e)<br>A 0000OOOO | 00000000 | | 00000000 Lh O f<br>LITT i<br>Direct Mount Handle Flange Handle<br>1.57 1.79 3.50<br>40 45.5 (88.9) Ø0.28<br>2.16 (Ø7.1)<br>(54.9) Ø0.50 1.55<br>0.86 1.06 (Ø12.7) (39.4)<br>(21.8) (26.9)<br>4.68<br>ee| (158.0)6.22 i :s (143.8)5.66 (25.4)1.00 oeU] (118.9) \<br>1.00 0.88<br>\, E (25.4) (22.3)<br>\, a—~<br>DIR-07 &<br>2.32<br>7.10 (58.9) 2.70<br>(180.3) (68.6)<br>FLH_<br>External Front & Right Side Pistol Handle<br>Handle Type Direction of Front Operation Direction of Right Side Operation Door Drilling Layout<br>I<br>I<br>Ø3.07<br>Ø 1.46<br>Ø78 4 Ø 0.27 Ø 37<br>Le lt 4 Ø 7<br>are it<br>4<br>0<br>H4X-06__<br>1.77<br>H12-03__ 45 TEST 0.55 0.55<br>14 14<br>90°<br>90°<br>ANDLE<br>Select<br>NFPA H<br>ONTACTS<br>Acc. C<br>UX<br>A<br>3.66 92.96<br>7.32 186 6.77 172 5.23 133<br>5.31 135<br>0.78 20<br>4.92 125 0<br>65° 0.78 20<br>**----- End of picture text -----**<br>
**397**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—200 & 400A Standard Class J**
## **For a Complete Assembly, Please Select:**
|**Switch**|**Switch**||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
||||||**Max Horsepower Rating**||**Max Horsepower Rating**||||
|||||**1-Phase**||**3-Phase**||**DC***|||
|**Amp**<br>**Rating**|**Fuse**<br>**Class**|**Number**<br>**of Poles**|**SCCR**|**220/**<br>**240Vac**|**220/**<br>**240Vac**|**440/**<br>**480Vac**|**600**<br>**Vac**|**125**<br>**Vdc**|**250**<br>**Vdc**|**Part**<br>**Number**|
|200|J|2|200kA|10|-|-|-|-|-|RDF200J-2|
|200|J|3|200kA|-|60|125|150|-|-|RDF200J-3|
|200|J|4|200kA|-|60|125|150|-|-|RDF200J-4|
|400|J|2|200kA|10|-|-|-|20|50|RDF400J-2|
|400<br>400|J<br>J|3<br>4|200kA<br>200kA|-<br>-|125<br>125|250<br>250|350<br>350|20<br>20|50<br>50|RDF400J-3<br>RDF400J-4|
400 J 4 200kA - 125 250 350 20 50 RDF400J-4 * DC Ratings use two poles in series. + **Terminal Lug Kit Switch Number Lugs Part Amp Rating of Poles Per Kit Wire Range Wire Type Number** 200 2 2 #6-300MCM 75°C Cu/Al LUG1-2 200 3 3 #6-300MCM 75°C Cu/Al LUG1-3 200 4 4 #6-300MCM 75°C Cu/Al LUG1-4 #4-600MCM or 400 2 2 75°C Cu/Al LUG2-2 Dual 1/0-250MCM #4-600MCM or 400 3 3 75°C Cu/Al LUG2-3 Dual 1/0-250MCM 236 ~~ee ee es~~ #4-600MCM or 400 4 4 75°C Cu/Al LUG2-4 Dual 1/0-250MCM ~~eeee ee~~ **+ Direct Mount Handle -** mounts directly to switch, no shaft required **For Switch Test Part Part Number Color Function Padlockable Number** All Switches Black Y Y DIR-07 ~~Fs~~ or **External Front Operated Pistol Handles -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 12 Black N Y Y H12-03B 1, 3R, 12 Red/Yellow N Y Y H12-03R 1, 3R, 4, 4X, 12 Black N Y Y H4X-06B 1, 3R, 4, 4X, 12 Red/Yellow N Y Y H4X-06R 1, 3R, 4, 4X, 12 Black Y Y Y H4X-06TB 1, 3R, 4, 4X, 12 Red/Yellow Y Y Y H4X-06TR or **Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 4, 4X, 12 Black N Y Y H4X-06BHD 1, 3R, 4, 4X, 12 Red/Yellow N Y Y H4X-06RHD **External Right Side Operated Pistol Handles -** shaft required **NEMA Test Part Type Color Function Padlockable Defeatable Number** 1, 3R, 4, 4X, 12 Black N Y N/A H4X-06SB 1, 3R, 4, 4X, 12 Red/Yellow N Y N/A H4X-06SR **Shafts for Pistol Handles Length Mounting Depth Part** + **in (mm) (X) in (mm) Number** 7.9 (200) 200A: 5.70-9.06 (145-230) SH5-200 ~~a ee~~ 400A: 7.87-10.24 (200-260) 12.6 (320) 200A: 5.70-13.78 (145-350)400A: 7.87-16.93 (200-380) SH5-320 15.7 (400) 200A: 5.70-16.93 (145-430) X SH5-400 400A: 7.87-18.10 (200-460) ~~=ee~~ **398** Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—200 & 400A**
## **Standard Class J**
**==> picture [520 x 607] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|or|
|(1)|Flange Handle|[(1)]|200A Only|- requires shaft operated mechanism|or|cable operated mechanism + cable|
|NEMA|Flange|Test|Part|
|Type|Style|Function|Padlockable|Defeatable|Number|
|(2)|1,|3R, 4, 12|Standard|N|Y|Y|FLH1|
|1, 3R, 4, 4X, 12|Chrome Plated|N|Y|Y|FLH2|
|Shaft Operated Flange Mechanism|[(2)]|200A Only|- includes shaft|
|For Enclosure Depth|Part|
|in (mm)|Number|
|6~24 (152~613)|FLRM|
|(3)|Cable Operated Flange Mechanism and Cable|200A Only|- must select Mechanism|[(3)]|and|Cable|[(4)]|
|Part|
|Item|Number|
|.|a|“|(4)|R|Cable Mechanism|s|FLCM|
|36” (900mm)|Cable|G|FLC36|
|oO|es|120” (3000mm) Cable60” (1500mm)|Cable|FLFLC120C60|
|or|
|NFPA Through the Door Handle Kit|- to be used with front pistol handle|
|Use with|Test|Part|
|Switch|Color|Function|Padlockable|Defeatable|Number|
|RDF200J-_|Red|N|Y|N|H79-2|
|RDF400J-_|Red|N|Y|N|H79-3|
|and …|
|Auxillary Contacts|
|Contact|Number of|Continuous|Voltage|Max Number of Aux|Part|
|Type|Contacts|Amp Rating|Rating|Contacts|per Switch Part Number|Number|
|NO|1|10A|600Vac|RDF200J-__: 4|BAC05|
|NC|1|10A|600Vac|RDF400J-__: 8|BAC06|
|and …|
|Terminal Shrouds|- includes terminal shroud for lineside or loadside|
|Switch Amp|Number|Part|
|Rating|of Poles|Number|
|200|2|TSH8-2TB|
|200|3|TSH8-3TB|
|200|4|TSH8-4TB|
|400|2|TSH9-2TB|
|400|3|TSH9-3TB|
|400|4|TSH9-4TB|
|Dimensions – in (mm)|
|• RDF200J-3|• RDF400J-3|
|7.72|
|196.2|7.08|
|6.61|180|
|168|4.37|10.19 (3P) - 12.79 (4P)|
|6.18|111.1|259 (3P) - 325 (4P)|
|157|
|\|vnleocnlaeen ||——o|o|Che|Cd|Ve CY|
|i7|if|bme)|5|=|st|I}Kf=|;|qjg-—_—-——peseco||||(eseec0|fescece2—_Teh(erie|h|Ht|5@|aaAaSeaa)ae|r|T|}||(aaaa=|_nase}|_|||aeos|_eans}|_|||sasn|__oane|}|E|l|
|j||||A=|=|=«lL||-|_||l|o©O°a|©on°|l|gooo00Beanpel00000goo000go0000HEE00000099898|||||||||||||[aonase|ooo0o0000000oooo0ncooo00PEsoooa080sa9558|| |||||||f|||eaesee|oooo0ocoooo0cooon0ooooo0GEGcocooos95038|||||alJ]Hee|ag||g|yp|—|,i|FI|=|f|sgm,|)|t|oo|i©|ed°o|4|@|Hl©)|{|l]|)|Scoc|Boes|Qoo00Beae|o500ooceeeee0000 | | | ||Sooc|Sees|ooooBeaa|eeneaensoo500000 | ||||cooocooo|Booo|cana|oooodoosoo00see|joolbaalWa[InAAR|&|oiif)-al|a}|
|}|||©|000000000000|||||ooo000000000|||||coooo00co0000|5|e|eo|©)|{||||sas89900|0000888|oooo00000|0c0o0000 | ||cooocooo|oooooc00|
|\|o||288388|||88688|||885585|
|w|bay|s-) =|Cc|ob|f——S|w—7|w|we|=_»|SA[fllo|[{|saseSooeaueeac00||||SassooooaeessaKe||||soeosagseansccoe|P=|
|1.41|PF|Series|0.9824.9|
|LE|36|anni|!|!|a|Th|fs|fs|
|WO|;|4|q|||j|f|6|me,|él|3.26|I,|
|5.11|TT|1.96|=|OW|Ir|YW|“t|Sy)|=|83|
|130|50|
|2.59|2.59|
|66|66|
**----- End of picture text -----**<br>
**399**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—200 & 400A Standard Class J**
## **Direct Mount Handle Flange Handle**
**==> picture [401 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.57 1.79 3.50<br>40 45.5 (88.9) Ø0.28<br>2.16 (Ø7.1)<br>(54.9) Ø0.50 1.55<br>0.86 1.06 (Ø12.7) (39.4)<br>(26.9)<br>(21.8)<br>4.68<br>5.66 1.00 (118.9)<br>6.22 (143.8) (25.4)<br>(158.0)<br>1.00 0.88<br>(25.4) (22.3)<br>DIR-07<br>2.32<br>7.10 (58.9) 2.70<br>(180.3) (68.6)<br>FLH_<br>5.31 135<br>**----- End of picture text -----**<br>
## **External Front & Right Side Pistol Handle**
**==> picture [524 x 121] intentionally omitted <==**
**----- Start of picture text -----**<br>
Handle Type Direction of Front Operation Direction of Right Side Operation Door Drilling Layout<br>I<br>I<br>Ø3.07<br>Ø 1.46<br>Ø78 4 Ø 0.27 Ø 37<br>4 Ø 7<br>0<br>H4X-06__<br>1.77<br>H12-03__ 45 TEST 0.55 0.55<br>14 14<br>90°<br>90°<br>0.78 20<br>4.92 125 0<br>65° 0.78 20<br>**----- End of picture text -----**<br>
## **Terminal Lugs**
**==> picture [180 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø 0.4<br>Ø 4.7<br>0.45<br>Ø11.6 2.8 0.63<br>71.5 15.88<br>1.52 0.46<br>38.8 11.68<br>200A 400A<br>LUG1-__ LUG2-__<br>1 25 1.3 35<br>0.25 6.35 1.8 46 0.44 11.13<br>1.12 28.6<br>**----- End of picture text -----**<br>
**400**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## Open & Enclosed Rotary Disconnect Switches **In-Stock and Ship Within 24 Hours**
The Bussmann **QuikShip Everyday Service** ensures the most common open and enclosed rotary disconnect switches **ship within 24 hours** to help you meet project timelines.
Contact your Bussmann representative for details.
www.cooperbussmann.com/Disconnects
**401**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—600 & 800A Standard Class J & Class L**
**For a Complete Assembly, Please Select:**
|+<br>.|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating, 3-Phase**<br>**Amp**<br>**Fuse**<br>**Number**<br>**220/**<br>**440/**<br>**Part**<br>**Rating**<br>**Class**<br>**of Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**600Vac**<br>**Number**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
||600|J|2|200kA||-|||-|-||RDF600J-2|
||600|J|3|200kA||200|||400|500||RDF600J-3|
||600|J|4|200kA||200|||400|500||RDF600J-4|
||800|L|2|200kA||-|||-|-||RDF800L-2|
||800|L|3|200kA||200|||500|500||RDF800L-3|
||800|L|4|200kA||200|||500|500||RDF800L-4|
||**Terminal Lug Kit**<br>**Switch**<br>**Number**<br>**Lugs**<br>**Part**<br>**Amp Rating**<br>**of Poles**<br>**Per Kit**<br>**Wire Range**<br>**Wire Type**<br>**Number**||||||||||||
||600-800||2|2||(2)#2-600MCM||||75°C Cu/Al||LUG5-2|
||600-800||3|3||(2)#2-600MCM||||75°C Cu/Al||LUG5-3|
||600-800||4|4||(2) #2-600MCM||||75°C Cu/Al||LUG5-4|
|**+**<br>.|||||||||||||
||**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**||||||||||||
||All Switches|||Black||Y|||Y|||DIR-08|
|or<br>~~———e~~|||||||||||||
|+<br>or<br>~~———e~~|**External Front Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~———e~~||||||||||||
||1, 3R,4,4X,12<br>~~———e~~||~~———e~~|Black<br>~~———e~~||N<br>~~———e~~|||Y<br>~~———e~~||Y<br>~~———e~~|H4X-07B<br>~~———e~~|
||1,3R,4,4X,12<br>~~———e~~||~~———e~~|Red/Yellow<br>~~———e~~||N<br>~~———e~~|||Y<br>~~———e~~||Y<br>~~———e~~|H4X-07R<br>~~———e~~|
||**Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~———e~~||||||||||||
||1, 3R,4,4X,12<br>~~———e~~||~~———e~~|Black<br>~~———e~~||N<br>~~———e~~|||Y<br>~~———e~~||Y<br>~~———e~~|H4X-07BHD<br>~~———e~~|
||1,3R,4,4X,12<br>~~———e~~||~~———e~~|Red/Yellow<br>~~———e~~||N<br>~~———e~~|||Y<br>~~———e~~||Y<br>~~———e~~|H4X-07RHD<br>~~———e~~|
||**Shafts for Pistol Handles**<br>**Length**<br>**Mounting Depth**<br>**Part**<br>**in(mm)**<br>**(X) in(mm)**<br>**Number**<br>~~———e~~||||||||||||
||7.9 (200)<br>~~———e~~||10.63~11.97(270~304)<br>~~———e~~||||X<br>~~———e~~|~~———e~~||||SH7-200<br>~~———e~~|
||12.6 (320)<br>~~———e~~||10.63~16.69 (270~424)<br>~~———e~~|||||||||SH7-320<br>~~———e~~|
||15.7 (400)<br>~~———e~~||10.63~19.84 (270~504)<br>~~———e~~|||||||||SH7-400<br>~~———e~~|
|or<br>~~———e~~<br>2,|||||||||||||
|2,|**NFPA Through the Door Handle Kit** - to be used with front pistol handle<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>||||||||||||
||All Switches<br>||Red<br>||||N<br>||Y<br>||N<br>|H79-4<br>|
|2,|and …<br>||||||||||||
|~~EEE~~|**Auxillary Contacts**<br>**Contact**<br>**Number of**<br>**Continuous**<br>**Voltage**<br>**Max Number of Aux**<br>**Part**<br>**Type**<br>**Contacts**<br>**Amp Rating**<br>**Rating**<br>**Contacts per Switch**<br>**Number**<br>~~EEE~~||||||||||||
||NO<br>~~EEE~~||1<br>~~EEE~~||10A<br>~~EEE~~||600Vac<br>~~EEE~~||8<br>~~EEE~~|||BAC05<br>~~EEE~~|
||NC<br>~~EEE~~||1<br>~~EEE~~||10A<br>~~EEE~~||600Vac<br>~~EEE~~||8<br>~~EEE~~|||BAC06<br>~~EEE~~|
|and …|||||||||||||
||**Terminal Shrouds** - includes terminal shroud for lineside or loadside<br>**Switch Amp**<br>**Number**<br>**Part**<br>**Rating**<br>**of Poles**<br>**Number**||||||||||||
||600-800||2|||||||||TSH10-2TB|
||600-800||3|||||||||TSH10-3TB|
||600-800||4|||||||||TSH10-4TB|
**402**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Fused Rotary Disconnect Switches—600 & 800A Standard Class J & Class L**
**==> picture [504 x 247] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – in (mm)<br>• RDF600J-3 • RDF800L-3 min 10.43<br>min 265<br>9.84 11.18 (3P) - 14.88 (4P)<br>250 6.10 284 (3P) - 378 (4P)<br>2.56 1.34<br>155<br>65 34<br>3.12 0.43<br>79.5 11<br>0.27<br>7 Ø 0.51 0.35<br>Ø13 9<br>2.32<br>59 2<br>18.58 14.96 51 3.7 3.7<br>472 380 94 94<br>Fuse Cover Fully Open 14.33 (3P) - 18.03 (4P)<br>364 (3P) - 458 (4P)<br>3.36 85.5<br>27<br>0. 7<br>3.54 90 11.81 300 10.23 260 fix 9.84 fix 250 5 126.5 18.54 471<br>27 7<br>0.<br>11.81 300 3.36 85.5<br>**----- End of picture text -----**<br>
## **Dimensions – in (mm)**
## **Direct Mount Handle**
**==> picture [93 x 122] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.36<br>60<br>3.35<br>85<br>DIR-08<br>7.48 190<br>**----- End of picture text -----**<br>
## **External Front Pistol Handle**
## **Terminal Lugs**
**==> picture [452 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.76<br>Handle Type Direction of Front Operation Door Drilling Layout 95.5<br>Ø3.07<br>Ø78 I<br>Ø 1.46<br>4 Ø 0.27 Ø 37 Ø10.20.40<br>4 Ø 7<br>3.15<br>80<br>0.55 0.55<br>H4X-07__ 61 14 14<br>600 to 800A<br>LUG5-__<br>90°<br>1.49 38<br>0.78 20<br>210 0<br>0.78 20<br>2.87 73 0.64 16.2<br>**----- End of picture text -----**<br>
**403**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Non-Fused Rotary Disconnect Switches—30 to 1200A**
## **Description**
Bussmann UL 98 non-fused rotary disconnect switches are versatile switches that “break” and “make” power circuits ON and OFF load.
## **Features**
- Make and break power under load
- Up to 200kA SCCR
- DIN-Rail or panel mount (30-100A)
- Disconnect switches are front, right side and direct handle operable (30-100A)
- Finger-safe (30-100A)
- Fully visualized breaking (100-1200A)
## **Agency Information**
- UL98, Guide WHTY, File E155130
- CSA 22.2 No. 4, File 257020
- Conforms with IEC 60947-3
## **Online Resources**
Visit www.cooperbussmann.com/Disconnects for:
- CAD Drawings
- Instruction Sheets
- UL Information
QuikShip Everyday Service ships the most common part numbers within 24 hours. Contact your Bussmann representative for details.
## **Related Cooper Bussmann Products**
**Data Sheet #** Modular Knifeblade Fuse Blocks 100-600A 3192 CH Series Class CC, Midget & 10x38 0-30A 3185 Finger-Safe Optima Series 0-30A 1102 Optima™ Protection Modules 0-30A 1109 CH Series Class J 0-60A 2144
## **Fuse Blocks**
## **Fuses Holders**
## **IEC Electrical Specifications**
||||**RD30-3**<br>bog|||**RD200-3**<br>**RD600-3**<br>Ai !<br>J®,RB,<br>eB|**RD200-3**<br>**RD600-3**<br>Ai !<br>J®,RB,<br>eB|**RD200-3**<br>**RD600-3**<br>Ai !<br>J®,RB,<br>eB|**RD200-3**<br>**RD600-3**<br>Ai !<br>J®,RB,<br>eB|**RD200-3**<br>**RD600-3**<br>Ai !<br>J®,RB,<br>eB|**RD200-3**<br>**RD600-3**<br>Ai !<br>J®,RB,<br>eB|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Part Number**||||||||||||||
|**3-Pole**||**RD30-3**|**RD60-3**||**RD100-3**|**RD100-3-SCCR**|**RD200-3**|**RD400-3**||**RD600-3**|**RD800-3**|**RD1000-3**|**RD1200-3**|
|**4-Pole**||**—**|**—**||**—**|**—**|**RD200-4**|**RD400-4**||**RD600-4**|**RD800-4**|**RD1000-4**|**RD1200-4**|
|Thermal Current Ith@40°C(A)||30|60||100|—|—|—||—|—|—|—|
|Rated insulation voltage Ui(V)||800|800||800|—|—|—||1000|1000|1000|1000|
|Rated impulse withstand voltage Uimp(kV)||8|8||8|—|—|—||12|12|12|12|
|**Rated Operation Currents Ie (A)**||||||||||||||
|Load DutyCategory<br>Rated Voltage||A(1)|A(1)||A(1)|—|—|—||A(1)|A(1)|A(1)|A(1)|
|400Vac<br>AC-22 A||32|63||100|—|—|—||630|800|1000|1200|
|400Vac<br>AC-23 A||32|63||100|—|—|—||630|800|1000|1000|
|690Vac<br>AC-22 A||32|63||80|—|—|—||500|630|630|630|
|690Vac<br>AC-23 A||32|63||63|—|—|—||200|400|400|400|
|**Operational Power (Vac) in AC-23 (kW)**<br>400V w/o prebreak AC(1)(2)<br>500V w/o prebreak AC(1)(2)<br>690V w/oprebreak AC(1)(2)<br>**Overload Capacity (Ue 415Vac)**<br>Rated short-time<br>makingcapacityIcm(kApeak) (3)<br>~~_i~~||15<br>15<br>18.5<br>12|30<br>30<br>30<br>12||45<br>45<br>45<br>12|—<br>—<br>—<br>—|—<br>—<br>—<br>—|—<br>355<br>450<br>560<br>560<br>—<br>450<br>560<br>560<br>560<br>—<br>185<br>400<br>400<br>400<br>—<br>48<br>75<br>48<br>75<br>~~em~~||||||
|**Fuse Protected Short-Circuit Withstand**<br>**(kA rms prospective)**<br>Short-Circuit Current (kA)(3)<br>Associated Fuse Rating (A) (3)||50<br>32|50<br>25<br>—<br>63<br>100<br>—<br>~~ff~~||||—<br>—|—<br>—|&|100<br>630|100<br>800|100<br>1000|100<br>1250|
|**Connection**<br>Minimum Cu cable cross section (mm2)<br>Minimum Cu busbar section (mm2)<br>Maximum Cu cable section(mm2)<br>~~|~~||2.5<br>—<br>70|2.5<br>—<br>70<br>xz||10<br>—<br>70|—<br>—<br>—|—<br>—<br>—|—<br>2x150<br>2x185<br>2x240<br>—<br>—<br>2x30x5<br>2x40x5<br>2x50x5<br>2x60x5<br>—<br>—<br>—<br>—<br>—<br>~~tH.~~||||||
|(1) A/B: Category with index A = frequent operation; category with index B = infrequent operation.<br>(2) The power value is given for information only; the current values vary from one manufacturer to another.<br>(3) For a rated operating voltage, Ue = 400Vac.<br>~~ee~~||||||||||||||
**404**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches** i
## **UL 98 Non-Fused Rotary Disconnect Switches—30 to 1200A**
## **Specifications**
|||**RD30-3**|||**RD200-3**|||**RD600-3**|**RD600-3**||
|---|---|---|---|---|---|---|---|---|---|---|
|**Part Number**|||||||||||
|**3-Pole**|**RD30-3**|**RD60-3**|**RD100-3**|**RD100-3-SCCR**|**RD200-3**|**RD400-3**|**RD600-3**|**RD800-3**|**RD1000-3**|**RD1200-3**|
|**4-Pole**|**—**|**—**|**—**|**—**|**RD200-4**|**RD400-4**|**RD600-4**|**RD800-4**|**RD1000-4**|**RD1200-4**|
|UL Standard|UL 98|UL 98|UL 98|UL 98|UL 98|UL 98|UL 98|UL 98|UL 98|UL 98|
|Max Ampacity|30A|60A|100A|100A|200A|400A|600A|800A|1000A|1200A|
|Switch Type|Compact|Compact|Compact|Standard|Standard|Standard|Standard|Standard|Standard|Standard|
|Handle Operation|Front/Side|Front/Side|Front/Side|Front|Front|Front|Front|Front|Front|Front|
|**UL Electrical Ratings**|||||||||||
|Max Voltage (AC)|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|
|Max Voltage (DC)|—|—|—|250Vdc|250Vdc|—|250Vdc|—|—|—|
|Maximum AC Horsepower Ratings<br>1-Phase, 120Vac<br>1-Phase, 240Vac<br>3-Phase, 240Vac<br>3-Phase, 480Vac|2<br>5<br>10<br>20|3<br>10<br>20<br>40|5<br>10<br>20<br>50|—<br>10<br>30<br>75|—<br>10<br>75<br>150|—<br>—<br>125<br>250|—<br>—<br>200<br>400|—<br>—<br>200<br>500|—<br>—<br>200<br>500|—<br>—<br>200<br>500|
|3-Phase, 600Vac|25|50|50|100|200|350|350|500|500|500|
|DC Horsepower Ratings|||||||||||
|125Vdc|—|—|—|—|—|—|20|—|—|—|
|250Vdc|—|—|—|—|—|—|50|—|—|—|
|**Electrical Characteristics**|||||||||||
|SCCR with Fuse|100kA|100kA|25kA/100kA*|200kA|200kA|200kA|200kA|100kA|100kA|100kA|
|Fuse Class|J|J|J|J|J|J|J|L|L|L|
|Max. Fuse Rating|30A|60A|100A|100A|200A|400A|600A|800A|1000A|1200A|
|Terminal Lugs/Kits|Integral|Integral|Integral|•|•|•|•|•|•|•|
|Lug Mounting Torque - Lb-In (N•m)|-|-|-|160 (18)|160 (18)|LUG2-_ 310 (35)|310 (35)|310 (35)|310 (35)|310 (35)|
|||||||LUG3-_ 398 (45)|||||
|Wire Type|75°C Cu|75°C Cu|75°C Cu|75°C Cu/Al|75°C Cu/Al|75°C Cu/Al|75°C Cu/Al|75°C Cu/Al|75°C Cu/Al|75°C Cu/Al|
|Wire Range & Torque - Lb-In (N•m)|||||||||||
|Solid|#12-10|#12-10|#12-10|—|—|—|—|—|—|—|
||35.4 (4)|35.4 (4)|35.4 (4)|—|—|—|—|—|—|—|
|Stranded|#10-1|#10-1|#10-1|#6-300MCM|#6-300MCM|LUG2-_ #4-600MCM|(2) #2-600MCM|(4) #2-600MCM|(4) #2-600MCM|(4) #2-600MCM|
||35.4 (4)|35.4 (4)|35.4 (4)|275 (31)|275 (31)|550 (62)|375 (42.4)|375 (42.4)|375 (42.4)|375 (42.4)|
||1/0|1/0|1/0|||Dual 1/0-250MCM|||||
||39.8 (4.5)|39.8 (4.5)|39.8 (4.5)|||550 (62)|||||
||2/0|2/0|2/0|||LUG3-_:(2) #6-2|||||
||44.3 (5)|44.3 (5)|44.3 (5)|||200 (22.6)|||||
|||||||(2) #1-350MCM|||||
|||||||375(42.4)|||||
|**Mechanical Characteristics**|||||||||||
|Endurances/Cycles|10,000|10,000|10,000|10,000|8000|6000|6000|3500|3500|3500|
|**Physical Characteristics**|||||||||||
|Dimensions|||||||||||
|See drawings on product pages|||||||||||
|Weight - Lbs (KG)|||||||||||
|3-Pole|1.3 (0.6)|1.3 (0.6)|1.3 (0.6)|4.2 (1.91)|4.2 (1.91)|10.0 (4.6)|18.1 (8.2)|19.6 (8.9)|19.6 (8.9)|19.6 (8.9)|
|4-Pole|—|—|—|—|5.0(2.3)|12.3(5.6)|23.9(10.9)|25.3(11.5)|25.3(11.5)|25.3(11.5)|
|**Environmental**|||||||||||
|Operating Temperature|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|-20°C to 70°C|
|FlammabilityRating|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|
|**Accessories**|||||||||||
|Lug Kit Part #|||||||||||
|3-Pole|Integral|Integral|Integral|•|•|•|•|•|•|•|
|4-Pole|—|—|—|—|•|•|•|•|•|•|
|Handles|||||||||||
|NEMA 1, 3R, 12|•|•|•|•|•|•|—|—|—|—|
|NEMA 1, 3R, 4, 4X, 12|•|•|•|•|•|•|•|•|•|•|
|Direct|•|•|•|•|•|•|•|•|•|•|
|Front Pistol|—|—|—|•|•|•|•|•|•|•|
|Front or Side Selector|•|•|•|—|—|—|—|—|—|—|
|Shaft c/s - mm|5x5|5x5|5x5|10x10|10x10|10x10|12x12|12x12|12x12|12x12|
|Shaft Guide|•|•|•|•|•|•|•|•|••|•|
|Shrouds|•|•|•|•|•|•|•|•|•|•|
|Additional Pole Accessory|•|•|•|—|—|—|—|—|—|—|
|Auxiliary Contacts|||||||||||
|NO + NC|•|•|•|•|•|•|•|•|•|•|
|(2)NO|•|•|•|—|—|—|—|—|—|—|
|• Available, see product page for details and part numbers.|Available, see product page for details and part numbers.||||||||||
|— Not available.|||||||||||
|* 25kA @ 600Vac, 100kA @ 480Vac.|||||||||||
**405**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Non-Fused Rotary Disconnect Switches—30, 60 and Compact 100A**
## **For a Complete Assembly, Please Select:**
|-<br>o|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**120**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Wire**<br>**Wire**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**Vac**<br>**240Vac**<br>**240Vac**<br>**480Vac Vac**<br>**Size**<br>**Type**<br>**Number**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||30|3|100kA|2|5|||10||20|25||#10-2/0 Str<br>#12-10 Sol|75°C Cu|RD30-3|
||60|3|100kA|3|10|||20||40|50||#10-2/0 Str<br>#12-10 Sol|75°C Cu|RD60-3|
||100|3<br>25/100kA*|25/100kA*|5|10|||20||50|50||#10-2/0 Str<br>#12-10 Sol|75°C Cu|RD100-3|
||* 100kA @480Vac, 25kA @ 600Vac.|||||||||||||||
|**+**||||||||||||||||
|~~a~~|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~a~~|||||||||||||||
||All Switches<br>~~a~~||Black<br>~~a~~||||||N||Y - On Switch||||DIR-02|
|or||||||||||||||||
|+<br>+<br>(2)<br>(1)<br>& ~~|~~|**External Front or Right Side Operated Selector Handles -**shaft required<br>**NEMA**<br>**Handle**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Length**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~eS~~|||||||||||||||
||1, 3R,4,4X,12<br>~~eS~~||Black<br>||Short<br>||||N<br>||Y<br>|||Y<br>|H4X-01B(1)<br>|
||1, 3R,4,4X,12<br>~~eSa~~<br>~~a~~||Red/Yellow<br>~~a~~<br>~~a~~||Short<br>~~a~~<br>~~a~~||||N<br>~~a~~<br>~~a~~<br>~~a~~||Y<br>~~a~~<br>~~a~~<br>~~a~~|||Y<br>~~a~~<br>~~a~~|H4X-01R(1)<br>~~a~~<br>~~a~~|
||1, 3R,4,4X,12<br>~~a~~<br>~~a~~<br>~~a~~||Black<br>~~a~~<br>~~a~~<br>~~a~~||Long<br>~~a~~<br>~~a~~<br>~~a~~||||N<br>~~a~~<br>~~a~~<br>~~a~~<br>~~a~~||Y<br>~~a~~<br>~~a~~<br>~~a~~<br>~~a~~|||Y<br>~~a~~<br>~~a~~<br>~~a~~|H4X-02B(2)<br>~~a~~<br>~~a~~<br>~~a~~|
||1,3R,4,4X,12<br>~~a~~||Red/Yellow<br>~~Ca~~||Long<br>~~Ca~~||||N<br>~~a~~||Y<br>~~a~~|||Y|H4X-02R(2)|
||**Shafts for Selector Handles**<br>**Length**<br>**Mounting Depth**<br>**Part**<br>**in(mm)**<br>**(X) in(mm)**<br>**Number**<br>~~es~~<br>~~pe~~<br>~~Ssee~~|||||||||||||||
||5.9 (150)<br>3<br>~~es~~<br>~~Ss~~||3.50~7.60 (89~193)<br>~~Ss~~||~~Ss~~|~~Ss~~|~~Ss~~|~~ee~~|||||||SH4-150<br>~~pe~~|
||7.9 (200)<br>3<br>~~es~~<br>~~Ss~~||3.50~9.50 (89~241)<br>~~Ss~~||||||||||||SH4-200<br>~~pe~~|
||12.6(320)<br>3.50~14.9<br>~~Ss~~||3.50~14.9(89~378)<br>~~Ss~~||||||||||||SH4-320|
||()<br>()<br>**Shaft Guide**<br>**Part**<br>**Number**<br>~~Ss ee~~<br>|||||||||||||||
||Required for 12.6” (320mm) long shafts, optional for other lengths<br>~~|~~<br>~~a~~||||||||||||||SH-GUIDE1<br>~~|~~<br>~~a~~|
|and …||||||||||||||||
|~~o~~<br>la|**Auxillary Contacts**<br>**Contact**<br>**Number of**<br>**Continuous**<br>**Voltage**<br>**Max Number of Aux**<br>**Part**<br>**Type**<br>**Contacts**<br>**Amp Rating**<br>**Rating**<br>**Contacts per Switch**<br>**Number**<br>~~o~~<br>|||||||||||||||
||NO+ NC<br>||1ofeach<br>||10A<br>|||||240Vac<br>||4<br>|||BAC01<br>|
||NO<br>||2<br>||10A<br>|||||240Vac<br>||4<br>|||BAC02<br>|
|and …<br>||||||||||||||||
|~~ee~~|**Terminal Shrouds** - includes terminal shroud for both lineside and loadside<br>**Switch Amp**<br>**Number**<br>**Location on**<br>**Part**<br>**Rating**<br>**of Poles**<br>**Switch**<br>**Number**<br>~~ee~~|||||||||||||||
||AllSwitches<br>~~ee~~||1(forswitched4th<br>pole)<br>~~ee~~|||||||||Lineside andLoadside<br>~~ee~~|||TSH3-1TB<br>~~ee~~|
||All Switches<br>~~ee~~||3<br>~~ee~~|||||||||Lineside and Loadside<br>~~ee~~|||TSH3-3TB<br>~~ee~~|
|and …<br>~~ee~~||||||||||||||||
|:<br>~~ee~~|**Switched**~~**4**~~**th**<br>**Pole** - converts 3-pole switch to 4-pole<br>**Switch Amp**<br>**Part**<br>**Rating**<br>**Number**<br>~~eS~~|||||||||||||||
||30<br>~~eS~~<br>~~ee~~||||||||||||||POLE98-30|
||60<br>~~eS~~<br>~~ee~~||||||||||||||POLE98-60|
||100<br>~~ee~~<br>~~a~~||||||||||||||POLE98-100|
**406**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Non-Fused Rotary Disconnect Switches—30, 60 and Compact 100A**
## **Dimensions - in (mm)**
**==> picture [518 x 198] intentionally omitted <==**
**----- Start of picture text -----**<br>
Direct Handle Operation External Front Operation External Right Side Operation<br>2.95 1.42 3.94 min./14.65 max.<br>75 3.07 36 100 min./372 max.<br>78 3.19<br>2.52 1 81<br>64 1.02 2 2.52<br>1 26 64 3.07<br>2 1.99 78 1.18 min./7.91 max. 1.42<br>50.6 1.02 30 min./201 max. 36<br>26<br>0.51<br>1 13 1<br>2<br>2<br>0.24<br>0.35 1.02 1.02 1.02 0.35<br>2.09 6 8.8 26 26 26 8.8<br>53 M5 0.26<br>2.08 6<br>53 0.34 1.02 1.02 1.02 0.34<br>1. Position for 1 switched 4 [th] pole (1 per device max.) or 1 auxiliary contact. 8.8 26 26 26 8.8<br>2. Position for 1 auxiliary contact only. M5<br>4.91 124.6 5.17 131.4 7.44 189<br>2.79 71<br>4.90 124.6 5.17 131.4 7.44 189 2.79 71<br>**----- End of picture text -----**<br>
Note: Maximum of 4 auxiliary contacts, or 3 auxiliary contacts + one switched 4[th] pole.
## **External Front or Right Side Operated Selector Handle**
**==> picture [523 x 182] intentionally omitted <==**
**----- Start of picture text -----**<br>
Handle Type Direction of Front Operation Direction of Right Side Operation Door Drilling Layouts<br>Ø3.07 1.57<br>Ø78 40<br>I I<br>4 Ø 0.27 0.11<br>4 Ø 7 3<br>H4X-01_ 1.42<br>36<br>0 0<br>Ø3.07<br>Ø78 Ø 1.22<br>Ø 31<br>Ø 0.88<br>With 4 Mounting Screws Ø 22.5 With Mounting Nut<br>1.45<br>37<br>H4X-02_<br>90° 90°<br>2.79 71<br>1.10 28 0.53 13.5<br>3.46 88<br>**----- End of picture text -----**<br>
**407**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Non-Fused Rotary Disconnect Switches—100, 200 and 400A**
## **For a Complete Assembly, Please Select:**
|+<br>Gs~~==>~~<br>~~[aaseseees~~|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**1-Phase**<br>**3-Phase**<br>**Amp**<br>**No. of**<br>**220/**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Number**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||100|3||200kA||10||30||75||100||RD100-3-SCCR|
||200|3||200kA||10||75||150||200||RD200-3|
||200|4||200kA||10||75||150||200||RD200-4|
||400|3||200kA||-||125||250||350||RD400-3|
||400|4||200kA||-||125||250||350||RD400-4|
||**Terminal Lug Kit**<br>**Switch**<br>**No. of**<br>**Lugs**<br>**Part**<br>**Amp Rating**<br>**Poles**<br>**Per Kit**<br>**Wire Range**<br>**Wire Type**<br>**Number**||||||||||||||
||100-200<br>~~==>~~|2<br>~~==>~~||2<br>~~==>~~||#6-300MCM<br>~~==>~~|||||||75°C Cu/Al<br>~~==>~~|LUG1-2<br>~~==>~~|
||100-200<br>~~==>~~|3<br>~~==>~~||3<br>~~==>~~||#6-300MCM<br>~~==>~~|||||||75°C Cu/Al<br>~~==>~~|LUG1-3<br>~~==>~~|
||100-200<br>~~==>~~|4<br>~~==>~~||4<br>~~==>~~||#6-300MCM<br>~~==>~~|||||||75°C Cu/Al<br>~~==>~~|LUG1-4<br>~~==>~~|
||400<br>~~==>~~|2<br>~~==>~~||2<br>~~==>~~||#4-600MCMor Dual 1/0-250MCM<br>~~==>~~|||||||75°C Cu/Al<br>~~==>~~|LUG2-2<br>~~==>~~|
||400<br>~~==>~~|3<br>~~==>~~||3<br>~~==>~~||#4-600MCMor Dual 1/0-250MCM<br>~~==>~~|||||||75°C Cu/Al<br>~~==>~~|LUG2-3<br>~~==>~~|
||400<br>~~==>~~|4<br>~~==>~~||4<br>~~==>~~||#4-600MCMor Dual 1/0-250MCM<br>~~==>~~|||||||75°C Cu/Al<br>~~==>~~|LUG2-4<br>~~==>~~|
||400<br>~~==>~~|2<br>~~==>~~||2<br>~~==>~~||(2)#6-350MCM<br>~~==>~~|||||||75°C Cu/Al<br>~~==>~~|LUG3-2<br>~~==>~~|
||400<br>~~==>~~<br>~~[aaseseees~~|3<br>~~==>~~<br>~~[aaseseees~~||3<br>~~==>~~<br>~~[aaseseees~~||(2)#6-350MCM<br>~~==>~~<br>~~[aaseseees~~|||||||75°C Cu/Al<br>~~==>~~<br>~~[aaseseees~~|LUG3-3<br>~~==>~~<br>~~[aaseseees~~|
||400<br>~~==>~~<br>~~[aaseseees~~|4<br>~~==>~~<br>~~[aaseseees~~||4<br>~~==>~~<br>~~[aaseseees~~||(2) #6-350MCM<br>~~==>~~<br>~~[aaseseees~~|||||||75°C Cu/Al<br>~~==>~~<br>~~[aaseseees~~|LUG3-4<br>~~==>~~<br>~~[aaseseees~~|
|**+**<br>Gs~~==>~~<br>~~[aaseseees~~|||||||||||||||
|~~[aaseseees~~|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~[aaseseees~~||||||||||||||
||All Switches<br>~~[aaseseees~~|~~[aaseseees~~||Black<br>~~[aaseseees~~||~~[aaseseees~~|N<br>~~[aaseseees~~|||Y<br>~~[aaseseees~~|||~~[aaseseees~~|DIR-03<br>~~[aaseseees~~|
|or<br>~~[aaseseees~~|||||||||||||||
|+<br>+<br>or<br>Oe|**External Front Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~SSSSS~~||||||||||||||
||1, 3R,12<br>~~SS~~||~~SS~~|Black<br>~~SSS~~||~~SSS~~|N<br>~~SSS~~|||Y<br>~~SSS~~|||Y<br>~~SSS~~|H12-03B<br>~~SSS~~|
||1, 3R,12<br>~~SS~~||~~SS~~|Red/Yellow<br>~~SSS~~||~~SSS~~|N<br>~~SSS~~|||Y<br>~~SSS~~|||Y<br>~~SSS~~|H12-03R<br>~~SSS~~|
||1, 3R,4,4X,12<br>~~SS~~||~~SS~~|Black<br>~~SSS~~||~~SSS~~|N<br>~~SSS~~|||Y<br>~~SSS~~|||Y<br>~~SSS~~|H4X-06B<br>~~SSS~~|
||1,3R,4,4X,12<br>~~SS~~||~~SS~~|Red/Yellow<br>~~SSS~~||~~SSS~~|N<br>~~SSS~~|||Y<br>~~SSS~~|||Y<br>~~SSS~~|H4X-06R<br>~~SSS~~|
||**Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**||||||||||||||
||1, 3R,4,4X,12<br>~~————eEO7O~~||~~————eEO7O~~|Black<br>~~————eEO7O~~||~~————eEO7O~~|N<br>~~————eEO7O~~|||Y<br>~~————eEO7O~~|||Y<br>~~————eEO7O~~|H4X-06BHD<br>~~————eEO7O~~|
||1,3R,4,4X,12<br>~~————eEO7O~~||~~————eEO7O~~|Red/Yellow<br>~~————eEO7O~~||~~————eEO7O~~|N<br>~~————eEO7O~~|||Y<br>~~————eEO7O~~|||Y<br>~~————eEO7O~~|H4X-06RHD<br>~~————eEO7O~~|
||**Shafts for Pistol Handles**<br>**Length**<br>**Mounting Depth**<br>**Part**<br>**in(mm)**<br>**(X) in(mm)**<br>**Number**||||||||||||||
||7.9 (200)||5.31~10.43 (135~265)||||X|||||||SH5-200|
||12.6 (320)||5.31~15.16 (135~385)|||||||||||SH5-320|
||15.7(400)||5.31~18.31(135~465)|||||||||||SH5-400|
||**Shaft Guide**<br>**Part**<br>**Number**||||||||||||||
||Required for 15.7” (400mm) long shafts, optional for other lengths|||||||||||||SH-GUIDE2|
|and …|||||||||||||||
|~~eo~~|**Auxillary Contacts**<br>**Contact**<br>**Number of**<br>**Continuous**<br>**Voltage**<br>**Max Number of Aux**<br>**Part**<br>**Type**<br>**Contacts**<br>**Amp Rating**<br>**Rating**<br>**Contacts per Switch**<br>**Number**<br>~~eo~~||||||||||||||
||NO+ NC<br>~~eo~~||1ofeach<br>~~eo~~||10.1A<br>~~eo~~||125-250Vac<br>~~eo~~||||2<br>~~eo~~|||BAC03*<br>~~eo~~|
||NO+ NC<br>~~eo~~||1ofeach<br>~~eo~~||10.1A<br>~~eo~~||125-250Vac<br>~~eo~~||||2<br>~~eo~~|||BAC04*<br>~~eo~~|
||NO+ NC<br>~~eo~~||1ofeach<br>~~eo~~||1A<br>~~eo~~||125Vac<br>~~eo~~||||2<br>~~eo~~|||BAC11*<br>~~eo~~|
||NO + NC<br>~~eo~~||1 of each<br>~~eo~~||1A<br>~~eo~~||125Vac<br>~~eo~~||||2<br>~~eo~~|||BAC12*<br>~~eo~~|
||* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.<br>~~eo~~||||||||||||||
**408**
**Disconnect Switches** Ba
## **UL 98 Non-Fused Rotary Disconnect Switches—100, 200 and 400A**
|**Terminal Shrouds**<br>**Switch Amp**<br>**R**<br>1<br>1<br>1<br>4<br>4<br>400A|**Terminal Shrouds** - includes terminal shroud for lineside or loadside<br>**Switch Amp**<br>**Number**<br>**Location on**<br>**Part**<br>**Rating**<br>**of Poles**<br>**Switch**<br>**Number**|**Terminal Shrouds** - includes terminal shroud for lineside or loadside<br>**Switch Amp**<br>**Number**<br>**Location on**<br>**Part**<br>**Rating**<br>**of Poles**<br>**Switch**<br>**Number**|**Terminal Shrouds** - includes terminal shroud for lineside or loadside<br>**Switch Amp**<br>**Number**<br>**Location on**<br>**Part**<br>**Rating**<br>**of Poles**<br>**Switch**<br>**Number**|**Terminal Shrouds** - includes terminal shroud for lineside or loadside<br>**Switch Amp**<br>**Number**<br>**Location on**<br>**Part**<br>**Rating**<br>**of Poles**<br>**Switch**<br>**Number**|**Terminal Shrouds** - includes terminal shroud for lineside or loadside<br>**Switch Amp**<br>**Number**<br>**Location on**<br>**Part**<br>**Rating**<br>**of Poles**<br>**Switch**<br>**Number**|
|---|---|---|---|---|---|
||100-200A|3|Lineside||TSH4-3T|
||100-200A|3|Loadside||TSH4-3B|
||100-200A|4|Lineside or Loadside||TSH4-4TB|
||400A|3|Lineside||TSH5-3T|
||400A|3|Loadside||TSH5-3B|
||400A|4|Lineside or Loadside||TSH5-4TB|
## **Dimensions - in (mm)**
**==> picture [518 x 439] intentionally omitted <==**
**----- Start of picture text -----**<br>
M<br>Terminal Lugs<br>J1 U Z<br>Y 1 0.88<br>W 0.45 Ø 0.4Ø 4.7 58.672.31 73.15 0.53<br>R1 Ø11.6 13.46<br>2.8 0.63<br>1.52 0.46 71.5 15.88<br>38.8 11.68<br>1.19<br>30.23<br>O l Why t ooo<br>0.25<br>6.35<br>100 to 200A 400A 400A<br>alien R2 ie C LUG1-__ L , A LUG2-__ ! = LUG3-__<br>T AD<br>F C<br>Switch Overall Terminal Switch Switch<br>Rating Dimen. Shrouds Body Mounting Connection<br>(A) C AC AD F 3p. F 4p. H J1 3p. J1 4p. K M 3p. M 4p. N R1 R2 T U V W Y Z AA AC<br>3.72 10.1 3.05 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.27 5.31 0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3 0.6<br>100<br>ee (94.6) (256) (77.5) (180) (230) (107) (55) (105) (45.6) (160) (210) (135) (9) (7) (50) (25) (30) (11) (3.5) (34.4) (160) (15)<br>3.72 10.1 3.05 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.27 5.31 0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3 0.6<br>200<br>(94.6) (256) (77.5) (180) (230) (107) (55) (105) (45.6) (160) (210) (135) (9) (7) (50) (25) (30) (11) (3.5) (34.4) (160) (15)<br>tt} 4.92 16 4.15 9.05 11.4 6.53 2.95 ee 5.31 eee 2.65 8.26 10.6 7.67 0.35 0.27 2.56 1.77 1.97 0.43 0.2 2.08 10.2 0.8<br>400<br>(128) (406) (115) (230) (290) (166) (75) (135) (67.5) (210) (270) (195) (9) (7) (65) (45) (50) (13) (5) (53) (260) (20)<br>ete t EE et} EEEte et EET tt TTT Pe TT EE YT<br>Direct Mount Handle External Front Handle<br>1.57 1.79<br>IP 40 45.5 r te<br>DIR-03 ~<br>Handle Type Direction of Front Operation Door Drilling Layout<br>I<br>H4X-06__<br>H12-03__<br>Ø3.07<br>Ø 1.46<br>Ø78 4 Ø 0.27 Ø 37<br>4 Ø 7<br>1.77<br>45 TEST 0.55 0.55<br>14 14<br>90°<br>1 25 1.3 35<br>CA<br>V 1.94 49.30<br>K<br>N AA AC<br>1.12 28.6 0.25 6.35 1.8 46 0.44 11.13 1.25 31.75<br>H<br>5.31 135<br>4.92 125 0<br>0.78 20<br>65° 0.78 20<br>**----- End of picture text -----**<br>
**409**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Non-Fused Rotary Disconnect Switches—600, 800, 1000 and 1200A**
## **For a Complete Assembly, Please Select:**
|+<br>:|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|**Switch**<br>**Max Horsepower Rating**<br>**Switch**<br>**3-Phase**<br>**DC***<br>**Amp**<br>**No. of**<br>**220/**<br>**440/**<br>**600**<br>**125**<br>**250**<br>**Part**<br>**Rating**<br>**Poles**<br>**SCCR**<br>**240Vac**<br>**480Vac**<br>**Vac**<br>**Vdc**<br>**Vdc**<br>**Number**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||600A|3||200kA||240|400||350||20||50|||RD600-3|
||600A|4||200kA||240|400||350||20||50|||RD600-4|
||800A|3||100kA||200|500||500||-||-|||RD800-3|
||800A|4||100kA||200|500||500||-||-|||RD800-4|
||1000A|3||100kA||200|500||500||-||-|||RD1000-3|
||1000A|4||100kA||200|500||500||-||-|||RD1000-4|
||1200A|3||100kA||200|500||500||-||-|||RD1200-3|
||1200A|4||100kA||200|500||500||-||-|||RD1200-4|
||* DC Ratings use twopoles in series.||||||||||||||||
||**Terminal Lug Kit**<br>**Switch**<br>**No. of**<br>**Lugs**<br>**Lugs Required**<br>**Wire**<br>**Part**<br>**Amp Rating**<br>**Poles**<br>**Per Kit**<br>**per Pole**<br>**Range**<br>**Wire Type**<br>**Number**||||||||||||||||
||600|3||3||1||(2)#2-600MCM||||||75°C Cu/Al||LUG5-3|
||600|4||4||1||(2)#2-600MCM||||||75°C Cu/Al||LUG5-4|
||800-1200|3||6||2||(4)#2-600MCM||||||75°C Cu/Al||LUG6-6|
||800-1200|4||8||2||(4) #2-600MCM||||||75°C Cu/Al||LUG6-8|
|||**+**|||||||||||||||
|~~|~~|**Direct Mount Handle -**<br>**For Switch**<br>**Part Number**|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**Test**<br>**Color**<br>**Function**<br>**Padlockable**||||||||||||||**Part**<br>**Number**|
||All Switches|Black||||||N||Y||||||DIR-04|
|or|||||||||||||||||
|+<br>or<br>+<br>(1)<br>(2)<br>(3)<br>(4)<br>=~~SSsS>—>~~<br>~~SS~~|**External Front Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~SSsS>—>~~||||||||||||||||
||1, 3R,4,4X,12<br>~~SSsS>—>~~||Black<br>~~SSsS>—>~~|||||N<br>~~SSsS>—>~~||Y<br>~~SSsS>—>~~||||Y<br>~~SSsS>—>~~||H4X-07B(1)<br>~~SSsS>—>~~|
||1, 3R,4,4X,12<br>~~SSsS>—>~~||Red/Yellow<br>~~SSsS>—>~~|||||N<br>~~SSsS>—>~~||Y<br>~~SSsS>—>~~||||Y<br>~~SSsS>—>~~||H4X-07R(1)<br>~~SSsS>—>~~|
||1, 3R,4,4X,12<br>~~SSsS>—>~~||Black<br>~~SSsS>—>~~|||||N<br>~~SSsS>—>~~||Y<br>~~SSsS>—>~~||||Y<br>~~SSsS>—>~~||H4X-08B(2)<br>~~SSsS>—>~~|
||1,3R,4,4X,12<br>~~SSsS>—>~~||Red/Yellow<br>~~SSsS>—>~~|||||N<br>~~SSsS>—>~~||Y<br>~~SSsS>—>~~||||Y<br>~~SSsS>—>~~||H4X-08R(2)<br>~~SSsS>—>~~|
||**Metallic Hasp (Heavy Duty) External Front Operated Pistol Handles -**shaft required<br>**NEMA**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~SS >~~||||||||||||||||
||1, 3R,4,4X,12<br>~~SS~~||Black<br>~~SS~~|||||N<br>~~SS~~||Y<br>~~SS >~~||||Y<br>~~>~~||H4X-07BHD(3)<br>~~>~~|
||1, 3R,4,4X,12<br>~~SS~~||Red/Yellow<br>~~SS~~|||||N<br>~~SS~~||Y<br>~~SS >~~||||Y<br>~~>~~||H4X-07RHD(3)<br>~~>~~|
||1, 3R,4,4X,12<br>~~SS~~||Black<br>~~SS~~|||||N<br>~~SS~~||Y<br>~~SS >~~||||Y<br>~~>~~||H4X-08BHD(4)<br>~~>~~|
||1,3R,4,4X,12<br>~~SS~~||Red/Yellow<br>~~SS~~|||||N<br>~~SS~~||Y<br>~~SS >~~||||Y<br>~~>~~||H4X-08RHD(4)<br>~~>~~|
||**Shafts for Pistol Handles**<br>**Length**<br>**Mounting Depth**<br>**in(mm)**<br>**(X) in(mm)**|||||||||||||||**Part**<br>**Number**|
||7.9 (200)<br>~~=~~||8.70~13.50 (221~343)|||||X|~~a~~|||||||SH6-200<br>SH6-320<br>SH6-400<br>~~a~~|
||12.6 (320)<br>~~=~~||8.70~18.23 (221~463)||||||||||||||
||15.7(400)<br>~~=~~||8.70~21.38(221~543)||||||||||||||
||()<br>()<br>**Shaft Guide**<br>**Part**<br>**Number**<br>~~=~~<br>~~a~~||||||||||||||||
||Required for 15.7” (400mm) long shafts, optional for other lengths|||||||||||||||SH-GUIDE2|
|and …|||||||||||||||||
|~~<=~~|**Auxillary Contacts**<br>**Contact**<br>**Number of**<br>**Continuous**<br>**Voltage**<br>**Max Number of Aux**<br>**Part**<br>**Type**<br>**Contacts**<br>**Amp Rating**<br>**Rating**<br>**Contacts per Switch**<br>**Number**<br>~~<=~~||||||||||||||||
||NO+ NC<br>~~<=~~||1ofeach<br>~~<=~~||10.1A<br>~~<=~~|||125-250Vac<br>~~<=~~||||2<br>BAC03*<br>~~<=~~|||||
||NO+ NC<br>~~<=~~||1ofeach<br>~~<=~~||10.1A<br>~~<=~~|||125-250Vac<br>~~<=~~||||2<br>BAC04*<br>~~<=~~|||||
||NO+ NC<br>~~<=~~||1ofeach<br>~~<=~~||1A<br>~~<=~~|||125Vac<br>~~<=~~||||2<br>BAC11*<br>~~<=~~|||||
||NO + NC<br>~~<=~~||1 of each<br>~~<=~~||1A<br>~~<=~~|||125Vac<br>~~<=~~||||2<br>BAC12*<br>~~<=~~|||||
||* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.<br>~~<=~~||||||||||||||||
**Disconnect Switches** a =
## **UL 98 Non-Fused Rotary Disconnect Switches—600, 800, 1000 and 1200A**
||and …|and …|and …|and …|and …|
|---|---|---|---|---|---|
|**Terminal Shrouds***<br>**Switch Amp**<br>**Ra**<br>600<br>600<br>800<br>800-1200A<br>~~CC~~|**Terminal Shrouds*** - includes terminal shroud for lineside or loadside<br>**Switch Amp**<br>**Number**<br>**Location on**<br>**Part**<br>**ating**<br>**of Poles**<br>**Switch**<br>**Number**|||||
||600A|3|Lineside or Loadside|de|TSH6-3TB|
||600A|4|Lineside or Loadside|de|TSH6-4TB|
||800-1200A|3|Lineside or Loadside|de|TSH7-3TB|
||800-1200A|4|Lineside or Loadside|Lineside or Loadside|TSH7-4TB|
||* Shroud for lineside included with switch.<br>~~CC~~|||||
|**Switch**<br>**Rating**<br>**(A)**|**Switch Terminal**<br>**Rating Shrouds**<br>**B**<br>~~ef~~|**Switch**<br>**Body**<br>**F 3p.**<br>**F 4p.**<br>**H**<br>**J 3p.**<br>**J 4p.**<br>~~ef~~<br>~~i~~<br>~~tfft~~<br>~~ftft~~|**Switch**<br>**Body**<br>**F 3p.**<br>**F 4p.**<br>**H**<br>**J 3p.**<br>**J 4p.**<br>~~ef~~<br>~~i~~<br>~~tfft~~<br>~~ftft~~|**Switch**<br>**Body**<br>**F 3p.**<br>**F 4p.**<br>**H**<br>**J 3p.**<br>**J 4p.**<br>~~ef~~<br>~~i~~<br>~~tfft~~<br>~~ftft~~|**Switch**<br>**Body**<br>**F 3p.**<br>**F 4p.**<br>**H**<br>**J 3p.**<br>**J 4p.**<br>~~ef~~<br>~~i~~<br>~~tfft~~<br>~~ftft~~|**Switch**<br>**Body**<br>**F 3p.**<br>**F 4p.**<br>**H**<br>**J 3p.**<br>**J 4p.**<br>~~ef~~<br>~~i~~<br>~~tfft~~<br>~~ftft~~|**Switch**<br>**Mounting**<br>**M 3p.**<br>**M 4p.**<br>**N**<br>**N1**<br>**N2**<br>~~fttl~~|**Switch**<br>**Mounting**<br>**M 3p.**<br>**M 4p.**<br>**N**<br>**N1**<br>**N2**<br>~~fttl~~|**Switch**<br>**Mounting**<br>**M 3p.**<br>**M 4p.**<br>**N**<br>**N1**<br>**N2**<br>~~fttl~~|**Switch**<br>**Mounting**<br>**M 3p.**<br>**M 4p.**<br>**N**<br>**N1**<br>**N2**<br>~~fttl~~|**Switch**<br>**Mounting**<br>**M 3p.**<br>**M 4p.**<br>**N**<br>**N1**<br>**N2**<br>~~fttl~~|**Connection**<br>**AA**<br>**Z**|**Connection**<br>**AA**<br>**Z**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|600|18.12<br>(460)<br>~~ef~~|11<br>(280)<br>~~ef~~<br>~~i~~|14.17<br>(360)|14.17<br>5.5<br>(140)<br>~~tfft~~|5<br>(127.5<br>~~ft~~|6.59<br>127.5)<br>(167.5)<br>~~ftft~~|10.03<br>(255)<br>~~fttl~~|13.19<br>(335)<br>~~tl~~|6.88<br>(175)|2.34<br>(59.5)|1.10<br>(28)|12.6<br>(320)|1.85<br>(47)|
|800|18.12<br>(460)<br>~~ef~~<br>~~a~~|14.64<br>(372)<br>~~ef~~<br>~~i~~<br>~~ee~~|19.37<br>(492)<br>~~ee~~|19.37<br>5.5<br>(140)<br>~~tf ft~~<br>~~ee~~|6.83<br>(173.5<br>~~ft~~<br>~~ee~~|9.19<br>173.5)<br>(233.5)<br>~~ft ft~~<br>~~ee~~|13.66<br>(347)<br>~~ft tl~~<br>~~ee~~|18.38<br>(467)<br>~~tl~~<br>~~ee~~|6.88<br>(175)<br>~~ee~~|2.34<br>(59.5)<br>~~ee~~|1.10<br>(28)<br>~~ee~~|13<br>(330)<br>~~ee~~|1.85<br>(47)|
|1000|18.12<br>(460)<br>~~ee~~<br>Pett|14.64<br>(372)<br>~~ee~~<br>Pett|19.37<br>(492)<br>~~ee~~<br>Pett|19.37<br>5.5<br>(140)<br>~~eeee~~<br>~~tt~~|6.83<br>(173.5<br>~~ee~~<br>~~tt~~|9.19<br>173.5)<br>(233.5)<br>~~ee~~<br>~~tt~~|13.66<br>(347)<br>~~ee~~<br>~~tt~~<br>||18.38<br>(467)<br>~~ee~~<br>~~tt~~|6.88<br>(175)<br>~~ee~~<br>~~tt~~|2.34<br>(59.5)<br>~~ee~~<br>~~tt~~ft|1.10<br>(28)<br>~~ee~~<br>ft|13<br>(330)<br>~~ee~~|1.85<br>(47)|
|1200|18.12<br>(460)<br>Pett|14.64<br>(372)<br>Pett|19.37<br>(492)<br>Pett|19.37<br>5.5<br>(140)<br>~~tt~~|6.83<br>(173.5)<br>~~tt~~|9.19<br>(173.5)<br>(233.5)<br>~~tt~~|13.66<br>(347)<br>~~tt~~<br>||18.38<br>(467)<br>~~tt~~|6.88<br>(175)<br>~~tt~~|2.34<br>(59.5)<br>~~tt~~ft|1.10<br>(28)<br>ft|13<br>(330)|1.85<br>(47)|
## **External Front Pistol Handles**
## **Direct Mount Handle**
## **Terminal Lugs**
**==> picture [492 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
Handle Type Direction of Front Operation 2.36 3.7695.5<br>60<br>I<br>Ø3.07<br>Ø78 0.40<br>Ø10.2<br>3.15<br>80<br>C e =<br>Door Drilling Layout<br>Ø 1.46<br>H4X-07__ 2.4 4 Ø 0.274 Ø 7 Ø 37<br>61 3.35<br>85 600 to 1200A<br>I DIR-04<br>Ø3.07Ø78 0.5514 0.514 5 LUG5-__, LUG6-__<br>0<br>4 H4X-08__ 4 2.3660<br>90°<br>90°<br>1.49 38<br>0<br>8.27 210 7.48 190<br>2.87 73 0.64 16.2<br>0.78 20<br>0.78 20<br>13.78 350<br>**----- End of picture text -----**<br>
**411**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 508 Non-Fused Rotary Disconnect Switches—16 to 80A**
## **Description**
Bussmann UL 508 load break disconnect switches allow safe control and safe disconnection of any motor application or to isolate a circuit within the panel.
These disconnect switches are compact and offer a wide variety of accessories like 4[th] poles, auxiliary contacts, door mounting and 6/8-Pole kits.
## **Features**
- Suitable as motor disconnect
- DIN-Rail or panel mount
- Door mount option
- Disconnect switches are front, right side or direct handle operable
- Finger-safe
## **Agency Information**
- UL508, Guide NLRV, File E155129
- CSA C22.2 No. 14, File 257020
- Conforms with IEC 60947-3
## **Online Resources**
Visit www.cooperbussmann.com/Disconnects for:
- CAD Drawings
- Instruction Sheets
- UL Information
QuikShip Everyday Service ships the most common part numbers within 24 hours. Contact your Bussmann representative for details.
|**Related Cooper Bussmann Products**|**Related Cooper Bussmann Products**||
|---|---|---|
|**Product**||**Data Sheet #**|
|**Fuses Blocks**|**Fuses Blocks**||
||Modular Knifeblade Fuse Blocks 100-600A|3192|
|**Fuses Holders**|**Fuses Holders**<br>CH Series Class CC, Midget & 10x38 0-30A|3185|
||Finger-Safe Optima Series 0-30A|1102|
||Optima™ Protection Modules 0-30A|1109|
||CH Series Class J 0-60A|2144|
## **IEC Electrical Specifications**
|**RD16-3-508**<br>**RD16-3-508 with 6-Pole Conversion Kit**|
|---|
|**Part Number**<br>**RD16-3-508**<br>**RD25-3-508**<br>**RD40-3-508**<br>**RD63-3-508**<br>**RD80-3-508**<br>Thermal Current Ith at 40°C(A)<br>16<br>25<br>40<br>63<br>80<br>Rated insulation voltage Ui(V)<br>800<br>800<br>800<br>800<br>800<br>Rated impulse withstand voltage Uimp(kV)<br>8<br>8<br>8<br>8<br>8<br>**Rated Operation Currents I**e**(A)**<br>Load Duty Category<br>Rated Voltage<br>A/B(1)<br>A/B(1)<br>A/B(1)<br>A/B(1)<br>A/B(1)<br>500Vac<br>AC-22 A/AC-22 B<br>16/16<br>25/25<br>40/40<br>63/63<br>80/80<br>500Vac<br>AC-23 A/AC-23 B<br>16/16<br>25/25<br>25/25<br>63/63<br>63/63<br>690Vac<br>AC-21 A/AC-21 B<br>16/16<br>25/25<br>40/40<br>63/63<br>80/80<br>690Vac<br>AC-22 A/AC-22 B<br>16/16<br>25/25<br>32/40<br>40/63<br>63/80<br>690Vac<br>AC-23 A/AC-23 B<br>16/16<br>25/25<br>25/25<br>40/40<br>40/40<br>~~po~~<br>~~po~~<br>~~Po~~<br>~~eT~~<br>~~————~~<br>~~—————~~|
|**Operational Power in AC-23 (kW)**<br>400Vac without prebreak AC(1)(2)<br>7.5<br>11<br>18.5<br>30<br>37<br>500Vac without prebreak AC(1)(2)<br>7.5<br>11<br>15<br>30<br>37<br>690Vac withoutprebreak AC(1)(2)<br>7.5<br>15<br>18.5<br>30<br>37|
|**Overload Capacity (Ue 415 Vac)**<br>Rated short-time withstand current 0.3 s. ICW(kA rms)(3)<br>2.5<br>2.5<br>2.5<br>3<br>3<br>Rated short-time makingcapacityIcm(kApeak) (3)<br>6<br>6<br>6<br>9<br>9|
|**Fuse Protected Short-Circuit Withstand (kA rms Prospective)**<br>Prospective short-circuit current (kA rms)(3)<br>50<br>50<br>50<br>50<br>50<br>Associated fuse rating (A) (3)<br>16<br>25<br>40<br>63<br>80|
|**Connection**<br>Minimum Cu cable cross section (mm2)<br>1.5<br>1.5<br>1.5<br>2.5<br>2.5<br>Maximum Cu cable section (mm2)<br>16<br>16<br>16<br>35<br>35<br>Tighteningtorque min/max(N•m)<br>2/2.2<br>2/2.2<br>2/2.2<br>3.5/3.85<br>3.5/3.85|
(1) A/B: Category with index A = frequent operation; category with index B = infrequent operation.
(2) The power value is given for information only; the current values vary from one manufacturer to another.
(3) For a rated operating voltage, Ue = 400Vac.
**412**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 508 Non-Fused Rotary Disconnect Switches—16 to 80A**
## **Specifications**
|**RD16-3-508**<br>**RD16-3-508 with 6-Pole Conversion Kit**|
|---|
|**Part Number**<br>**RD16-3-508**<br>**RD25-3-508**<br>**RD40-3-508**<br>**RD63-3-508**<br>**RD80-3-508**<br>UL Standard<br>UL 508<br>UL 508<br>UL 508<br>UL 508<br>UL 508<br>Max Ampacity<br>16A<br>25A<br>40A<br>63A<br>80A<br>Handle Operation<br>Front/Side<br>Front/Side<br>Front/Side<br>Front/Side<br>Front/Side<br>**UL Electrical Ratings**<br>Max Voltage (AC)<br>600Vac<br>600Vac<br>600Vac<br>600Vac<br>600Vac<br>Maximum Horsepower Ratings<br>3-Phase, 208Vac<br>3<br>7.5<br>7.5<br>15<br>15<br>3-Phase, 240Vac<br>5<br>7.5<br>7.5<br>20<br>20<br>3-Phase, 480Vac<br>10<br>15<br>20<br>40<br>40<br>3-Phase,600Vac<br>10<br>20<br>25<br>40<br>40<br>**Electrical Characteristics**<br>SCCR with Fuse<br>65kA<br>65kA<br>10/65kA<br>50/65kA<br>50/65kA<br>Recommended Upstream<br>Fuse Class<br>J<br>J<br>J<br>J<br>J<br>Max. Fuse Rating<br>30A<br>30A<br>60/30A<br>100/60A<br>100/60A<br>Terminals<br>Integral<br>Integral<br>Integral<br>Integral<br>Integral<br>Wire Type<br>75°C Cu<br>75°C Cu<br>75°C Cu<br>75°C Cu<br>75°C Cu<br>Wire Range & Torque - Lb-IN (N•m)<br>Solid<br>Single<br>#14-10<br>#14-10<br>#14-10<br>#14-10<br>#14-10<br>26.5 (3)<br>26.5 (3)<br>26.5 (3)<br>31.1 (3.5)<br>31.1 (3.5)<br>Dual<br>#12<br>#12<br>#12<br>#12<br>#12<br>26.5 (3)<br>26.5 (3)<br>26.5 (3)<br>31.1 (3.5)<br>31.1 (3.5)<br>Stranded<br>Single<br>#14-4<br>#14-4<br>#14-4<br>#14-1<br>#14-1<br>26.5 (3)<br>26.5 (3)<br>26.5 (3)<br>31.1 (3.5)<br>31.1 (3.5)<br>Dual<br>#14-12<br>#14-12<br>#14-12<br>#10-6<br>#10-6<br>26.5(3)<br>26.5(3)<br>26.5(3)<br>31.1(3.5)<br>31.1(3.5)<br>~~[_OC—CsCSCSCSC‘C(SNCO~~<br>~~po~~<br>~~pd~~<br>~~TTT~~<br>~~Sn~~<br>~~ee~~<br>~~oO~~|
|**Mechanical Characteristics**<br>Endurances/Cycles<br>10,000<br>10,000<br>10,000<br>10,000<br>10,000|
|**Physical Characteristics**<br>Dimensions - See drawings on product pages<br>Weight - Lb(KG)<br>0.5(0.2)<br>0.5(0.2)<br>0.5(0.2)<br>0.7(0.32)<br>0.7(0.32)|
|**Environmental**<br>Operating Temperature<br>-20°C to 70°C<br>-20°C to 70°C<br>-20°C to 70°C<br>-20°C to 70°C<br>-20°C to 70°C<br>FlammabilityRating<br>UL 94-V0<br>UL 94-V0<br>UL 94-V0<br>UL 94-V0<br>UL 94-V0|
|**Accessories**<br>Handles<br>Direct<br>DIR-01<br>DIR-01<br>DIR-01<br>DIR-01<br>DIR-01<br>Short Selector/NEMA 1, 3R, 4, 4X, 12<br>H4X-01B<br>H4X-01B<br>H4X-01B<br>H4X-01B<br>H4X-01B<br>H4X-01R<br>H4X-01R<br>H4X-01R<br>H4X-01R<br>H4X-01R<br>Long Selector/NEMA 1, 3R, 4, 4X, 12<br>H4X-02B<br>H4X-02B<br>H4X-02B<br>H4X-02B<br>H4X-02B<br>H4X-02R<br>H4X-02R<br>H4X-02R<br>H4X-02R<br>H4X-02R<br>Shafts - 5x5mm<br>5.9”/150mm<br>SH4-150<br>SH4-150<br>SH4-150<br>SH4-150<br>SH4-150<br>7.9”/200mm<br>SH4-200<br>SH4-200<br>SH4-200<br>SH4-200<br>SH4-200<br>12.6”/320mm<br>SH4-320<br>SH4-320<br>SH4-320<br>SH4-320<br>SH4-320<br>Shaft Guide<br>SH-GUIDE1<br>SH-GUIDE1<br>SH-GUIDE1<br>SH-GUIDE1<br>SH-GUIDE1<br>Door Mount Kit<br>DOOR-508<br>DOOR-508<br>DOOR-508<br>DOOR-508<br>DOOR-508<br>Shrouds/Switch Amps<br>1-Pole<br>TSH1-1TB<br>TSH1-1TB<br>TSH1-1TB<br>3-Pole (Loadside and Lineside)<br>TSH1-3TB<br>TSH1-3TB<br>TSH1-3TB<br>TSH2-3TB<br>TSH2-3TB<br>Switched 4th<br>Pole/Switch Amps<br>POLE-16<br>POLE-25<br>POLE-40<br>—<br>—<br>Auxiliary Contacts<br>NO + NC (1 ea.)<br>BAC01<br>BAC01<br>BAC01<br>BAC01<br>BAC01<br>(2) NO<br>BAC02<br>BAC02<br>BAC02<br>BAC02<br>BAC02<br>AC Ratings<br>Volts<br>240Vac<br>240Vac<br>240Vac<br>240Vac<br>240Vac<br>Amps<br>10A<br>10A<br>10A<br>10A<br>10A<br>6-/8-Pole Conversion Kit<br>Gangs two switches of same rating,16-80A switch amps<br>KIT-6POLE<br>KIT-6POLE<br>KIT-6POLE<br>KIT-6POLE<br>KIT-6POLE<br>— Not available.|
**413**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 508 Non-Fused Rotary Disconnect Switches—16, 25, 40, 63 and 80A**
## **For a Complete Assembly, Please Select:**
|ee)|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|**Switch**<br>**Switch**<br>**Max**<br>**Max Horsepower Rating, 3-Ph**<br>**Amp**<br>**No. of**<br>**SCCR**<br>**Class J**<br>**208**<br>**220/**<br>**440/**<br>**600**<br>**Part**<br>**Rating**<br>**Poles**<br>**@600V**<br>**Fuse**<br>**Vac**<br>**240Vac 480Vac**<br>**Vac**<br>**Wire Size**<br>**Wire Type**<br>**Number**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||16|3<br>~~||]~~|65kA<br>~~|]~~|30A<br>~~|]titi~~||3<br>~~titi~~|5<br>~~titi~~|||10<br>~~titi~~|10<br>~~titiio~~||#14-#10 Sol<br>Dual #12 Sol<br>#14-#4 Str<br>Dual #14-#12Str<br>~~ioot~~||75°C Cu<br>~~ot |~~|RD16-3-508<br>~~|~~|
||25<br>~~Pf~~|3<br>~~||]~~<br>~~Pftd~~|65kA<br>~~|]~~<br>~~td~~|30A<br>~~|]titi~~<br>~~tditt~~||7.5<br>~~titi~~<br>~~itt~~|7.5<br>~~titi~~<br>~~itt~~|||15<br>~~titi~~<br>~~itt~~|20<br>~~titiio~~<br>~~itt~~||#14-#10 Sol<br>Dual #12 Sol<br>#14-#4 Str<br>Dual #14-#12Str<br>~~ioot~~<br>~~pp~~||75°C Cu<br>~~ot |~~<br>~~pp~~|RD25-3-508<br>~~|~~<br>~~pp~~|
||40<br>~~Pf~~|3<br>~~| |]~~<br>~~Pftd~~|10kA<br>65kA<br>~~|]~~<br>~~td~~|60A<br>30A<br>~~|] titi~~<br>~~tditt~~||7.5<br>~~titi~~<br>~~itt~~|7.5<br>~~titi~~<br>~~itt~~|||20<br>~~titi~~<br>~~itt~~|25<br>~~titi io~~<br>~~itt~~||#14-#10 Sol<br>Dual #12 Sol<br>#14-#4 Str<br>Dual #14-#12Str<br>~~io ot~~<br>~~pp~~||75°C Cu<br>~~ot |~~<br>~~pp~~|RD40-3-508<br>~~|~~<br>~~pp~~|
||63<br>~~Pf~~|3<br>~~Pf td~~|50kA<br>65kA<br>~~td~~|100A<br>60A<br>~~td itt~~||15<br>~~itt~~|20<br>~~itt~~|||40<br>~~itt~~|40<br>~~itt ~~||#14-#10 Sol<br>Dual #12 Sol<br>#14-#1 Str<br>Dual #10-#6 Str<br> ~~pp~~||75°C Cu<br>~~pp~~|RD63-3-508<br>~~pp~~|
||80|3|50kA<br>65kA|100A<br>60A||15|20|||40|40||#14-#10 Sol<br>Dual #12 Sol<br>#14-#1 Str<br>Dual #10-#6 Str||75°C Cu|RD80-3-508|
|**+**<br>~~eee~~<br>~~eee~~|||||||||||||||||
|~~eee~~|**Direct Mount Handle -**mounts directly to switch, no shaft required<br>**For Switch**<br>**Test**<br>**Part**<br>**Part Number**<br>**Color**<br>**Function**<br>**Padlockable**<br>**Number**<br>~~eee~~<br>~~eee~~||||||||||||||||
||All Switches<br>~~eee~~||Black<br>~~eee~~|||~~eee~~||N|||Y - On Switch<br>~~eee~~|||~~eee~~||DIR-01<br>~~eee~~|
|or<br>~~eee~~<br>~~eee~~|||||||||||||||||
|+<br>+<br>+<br>(2)<br>(1)<br>a) S <br>a ~~———~~<br>~~4~~<br>~~|~~<br>a|**External Front or Right Side Operated Selector Handles -**shaft required<br>**NEMA**<br>**Handle**<br>**Test**<br>**Part**<br>**Type**<br>**Color**<br>**Length**<br>**Function**<br>**Padlockable**<br>**Defeatable**<br>**Number**<br>~~**es**~~<br>~~**nD(**QQ~~||||||||||||||||
||1, 3R,4,4X,12<br>~~**es**~~||Black<br>~~**nD**~~|||Short<br>~~**(**~~||N<br>~~**(**~~<br>~~I(OO~~|||Y<br>~~**(**QQ~~<br>~~(OO~~|||Y<br>~~QQ~~<br>~~(OO~~||H4X-01B(1)<br>~~QQ~~<br>~~(OO~~|
||1, 3R,4,4X,12<br>~~**es**~~<br>~~es~~||Red/Yellow<br>~~**nD**~~<br>~~nD~~|||Short<br>~~**(**~~<br>~~(QQ~~||N<br>~~**(**~~<br>~~I(OO~~<br>~~(QQ~~|||Y<br>~~**(**QQ~~<br>~~(OO~~<br>~~(QQ~~|||Y<br>~~QQ~~<br>~~(OO~~<br>~~(QQ~~||H4X-01R(1)<br>~~QQ~~<br>~~(OO~~<br>~~(QQ~~|
||1, 3R,4,4X,12<br> ~~**es**~~<br>~~es~~<br>~~nD~~||Black<br>~~**nD** ~~<br>~~nD~~<br>~~nD~~|||Long<br> ~~**(**~~<br>~~(QQ~~||N<br>~~**(**~~<br>~~I(OO~~<br>~~(QQ~~<br>~~QO~~|||Y<br>~~**(**QQ~~<br>~~(OO~~<br>~~(QQ~~<br>~~QO~~|||Y<br>~~QQ~~<br>~~(OO~~<br>~~(QQ~~<br>~~QO~~||H4X-02B(2)<br>~~QQ~~<br>~~(OO~~<br>~~(QQ~~|
||1,3R,4,4X,12<br>~~es~~<br>~~nD~~||Red/Yellow<br>~~nD~~<br>~~nD~~|||Long<br>~~(QQ~~||N<br>~~(QQ~~<br>~~QO~~|||Y<br>~~(QQ~~<br>~~QO~~|||Y<br>~~(QQ~~<br>~~QO~~||H4X-02R(2)<br>~~(QQ~~|
||**Shafts for Selector Handles** - required for 12.6” (320mm) shafts<br>**Length**<br>**Mounting Depth**<br>**Part**<br>**in(mm)**<br>**(X) in(mm)**<br>**Number**<br>~~nD~~<br>~~QO~~<br>~~es~~<br>~~———~~<br>~~fi~~<br>~~en~~<br>~~ee~~||||||||||||||||
||5.9 (150)<br>~~es~~<br>~~———~~||3.50-7.60 (89-193)<br>~~es~~<br>~~fi~~|||X<br>~~fi~~<br>~~en~~||||||||||SH4-150<br>SH4-200<br>SH4-320<br>~~ee~~|
||7.9 (200)<br>~~es~~<br>~~———~~||3.50-9.50 (89-241)<br>~~es~~<br>~~fi~~||||||||||||||
||12.6(320)<br>~~es~~<br>~~———~~||3.50-14.9(89-378)<br>~~es~~<br>~~fi~~||||||||||||||
||()<br>()<br>**Shaft Guide**<br>**Part**<br>**Number**<br>~~———~~<br>~~fi~~<br>~~en~~<br>~~ee~~<br>~~4~~||||||||||||||||
||Required for 12.6”(320mm)longshafts,optional for other lengths.<br>~~4~~<br>~~a~~|||||||||||||||SH-GUIDE1|
||**Door Mount Kit** - for mounting switch on the right side of the enclosure or directly on the enclosure door<br>using switch side operation shaft location. Kit includes a shaft._Order switch and selector handle separately_<br>.<br>**Switch**<br>**Part**<br>**Rating**<br>**Number**<br>~~4~~<br>~~|~~||||||||||||||||
||All Switches - kit includes shaft<br>~~|~~|||||||||||||||DOOR-508|
|and …<br>jj,~~Ts~~|||||||||||||||||
|jj,|**Auxillary Contacts**<br>**Contact**<br>**Number of**<br>**Continuous**<br>**Voltage**<br>**Max Number of Aux**<br>**Part**<br>**Type**<br>**Contacts**<br>**Amp Rating**<br>**Rating**<br>**Contacts per Switch**<br>**Number**<br>~~Ts~~||||||||||||||||
||NO+ NC<br><br>~~ee~~||1 Ea<br>~~Ts~~||10A<br>~~Ts~~<br>~~(RU~~||||240Vac<br>~~Ts~~<br>~~(RU~~|||4<br>~~Ts~~<br>~~I~~||||BAC01<br>~~Ts~~|
||NO<br><br>~~ee~~||2<br>~~Ts~~||10A<br>~~Ts~~<br>~~(RU~~||||240Vac<br>~~Ts~~<br>~~(RU~~|||4<br>~~Ts~~<br>~~I~~||||BAC02<br>~~Ts~~|
##
**414**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 508 Non-Fused Rotary Disconnect Switches—16, 25, 40, 63 and 80A**
**==> picture [520 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
and …<br>Terminal Shrouds - includes terminal shroud for both lineside and loadside<br>Switch Amp Number Location on Part<br>Rating of Poles Switch Number<br>16-40A 1 (for switched 4 [th] pole) Lineside and Loadside TSH1-1TB<br>16-40A 3 Lineside and Loadside TSH1-3TB<br>63-80A 3 Lineside and Loadside TSH2-3TB<br>and …<br>Switched 4 [th] Pole - converts 3-pole switch to 4-pole switch<br>Switch Amp Part<br>Rating Number<br>y ee 16 POLE-16<br>ib 25 Po POLE-25<br>_ a 40 eee POLE-40<br>and …<br>6-Pole Conversion Kit - creates a 6-pole switch by ganging two 3-pole switches of equal rating<br>Switch Amp Part<br>Rating Number<br>All Switches KIT-6POLE*<br>* Kit ships with a direct handle. If external handle is needed order a selector handle and shaft for the UL 508 Rotary Disconnect Switches.<br>Order switches separately. i —“CSSCSSC‘C‘C Note: To create an 8-pole switch from 16 to 40 amp switches, use two 3-pole switches of equal ratings plus two switched 4 [th] poles (part # POLE-_).<br>pees) sete Soe Switched 4 - [th] Pole<br>Configurations.<br>HROUDS<br>S<br>OLE<br>P<br>TH<br>. 4<br>W<br>S<br>Accessories<br>IT<br>K<br>OLE<br>6-P<br>**----- End of picture text -----**<br>
## **Dimensions – in (mm)**
**==> picture [105 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Direct Handle Operation<br>**----- End of picture text -----**<br>
## **External Front Operation**
## **External Side Operation**
**==> picture [507 x 158] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.42 E<br>2.95 36 3.1981 F D 1.42<br>752.52 F 1 2.5264 M 36<br>64 , 2 1 M ne 2 50.61.99 1 J 1 2<br>2 0 | Je)<br>hea | == i ) : i = . [ i er = eas o 6h o pPF 7 ay 7 |<br>ti < Oleialals = | Lo of s o pBielo > [<br>0.24 0.35 F1 T F1 0.35<br>oF 1.97 6 8.8 M5 pee 8.8 RL 0.35 opie F1 F1 0.35<br>50 8.8 T 8.8<br>1. Position for 1 switched 4 [th] pole (1 per device max.) or 1 auxiliary contact. 0.23<br>6 M5<br>2. Position for 1 auxiliary contact only. 1.96<br>Note: Maximum of 4 auxiliary contacts, or 3 auxiliary contacts + one switched 4 [th] pole. 50<br>G 2.67 68 N AC<br>G 2.68 68 N AC ø 2.79 ø 71<br>**----- End of picture text -----**<br>
|**Switch**<br>**Rating (A)**|**Overall**<br>**Dimensions**<br>**D min**<br>**D max**<br>**E min**<br>**E max**|**Overall**<br>**Dimensions**<br>**D min**<br>**D max**<br>**E min**<br>**E max**|**Overall**<br>**Dimensions**<br>**D min**<br>**D max**<br>**E min**<br>**E max**|**Overall**<br>**Dimensions**<br>**D min**<br>**D max**<br>**E min**<br>**E max**|**Terminal **<br>**Shroud**<br>**AC**|**Switch**<br>**Switch**<br>**Body**<br>**Mounting**<br>**F**<br>**F1**<br>**G**<br>**J**<br>**M**|**Switch**<br>**Switch**<br>**Body**<br>**Mounting**<br>**F**<br>**F1**<br>**G**<br>**J**<br>**M**|**Switch**<br>**Switch**<br>**Body**<br>**Mounting**<br>**F**<br>**F1**<br>**G**<br>**J**<br>**M**|**Switch**<br>**Switch**<br>**Body**<br>**Mounting**<br>**F**<br>**F1**<br>**G**<br>**J**<br>**M**|**Switch**<br>**Mounting**<br>**M**<br>**N**|**Switch**<br>**Mounting**<br>**M**<br>**N**|**Connection**<br>**T**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|16 to 40|1.18<br>(30)|9.25<br>(235)|3.94<br>(100)|14.64<br>(372)|4.33<br>(110)|1.77<br>(45)|0.59<br>(15)|2.67<br>(68)|0.59<br>1.18<br>(15)<br>(|1.18<br>(30)|2.95<br>(75)|0.59<br>(15)|
|63 to 80|1.18<br>(30)|9.25<br>(235)|3.93<br>(100)|14.64<br>(372)|4.33<br>(110)|2.06<br>(52.5)|0.69<br>(17.5)|2.99<br>(76)|0.69<br>1.38<br>(17.5)<br>(35)|1.38<br>(35)|3.35<br>(85)|0.69<br>(17.5)|
**415**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 508 Non-Fused Rotary Disconnect Switches—16, 25, 40, 63 and 80A**
## **Dimensions – in (mm)**
**==> picture [213 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
Direct Front Operation for 6/8-Pole Disconnects<br>F<br>J 3.50<br>F2 89<br>2 1 X M 2.0652.5 1 2 3.0778<br>0.24<br>0.358.8 F1 T T 0.29 F1 0.358.8 6 1.6943 34.71.36<br>2.06 7.5<br>52.5<br>N G 2.67 68 1.77 45<br>**----- End of picture text -----**<br>
## **External Front Operation for 6/8-Pole Disconnects**
|||||||||1.77<br>3.07<br>1.36<br>1.69<br>3.50<br>89<br>78<br>43<br>34.7<br>45|1.77<br>3.07<br>1.36<br>1.69<br>3.50<br>89<br>78<br>43<br>34.7<br>45|1.77<br>3.07<br>1.36<br>1.69<br>3.50<br>89<br>78<br>43<br>34.7<br>45|X<br>N<br>G<br>2.67<br>T T<br>2.<br>M<br>F2<br>J<br>F1<br>0.35<br>2<br>1<br>68<br>8.8<br>5|X<br>N<br>G<br>2.67<br>T T<br>2.<br>M<br>F2<br>J<br>F1<br>0.35<br>2<br>1<br>68<br>8.8<br>5|||F|F1<br>2<br>1<br>8.8<br>0.35|F1<br>2<br>1<br>8.8<br>0.35||1.42<br>E<br>ø 2.79<br>36<br>ø 71|1.42<br>E<br>ø 2.79<br>36<br>ø 71|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|N||||F||0.24<br>2<br>1<br>6<br>8.8<br>0.35|||||||||||||||
|||67|X<br><br>M<br>F2<br>J<br>2<br>1<br>8|||2<br>1<br><br>0.35||||||||X<br>.<br>M<br>F2<br>J<br>2<br>1<br>68||F1<br>2<br>1<br>8.8<br>0.35|||||
|||||2.06<br>52.5||||3.07<br>78|||||||2.06<br>52.5||||||
|||2.<br>T T<br>2<br>F1<br>0.35<br>6<br>8.8|||F1|||1<br>1.69<br><br>|.36<br>||||||0.29||||||
|||||0.29<br>06<br>7.5||8.8||43<br>3|||||||06<br><br>7.5||||||
|||5||2.5|||||||||||.5||||||
||||||||||||||||||||||
|1. Po<br>2. Po<br>Note:|sit<br>sit<br>M|ion for 1 switched<br>ion for 1 auxiliary c<br>aximum of 4 auxili||~~4~~th<br>pole (1 p<br>ontact only.<br>ary contacts|er dev<br>, or 3|ice max.) or 1<br>auxiliary conta||auxiliary c<br>cts + one|ontact.<br>switched 4th<br>pole.||||||||||||
||||||||||||||||||||||
|**Overa**<br>**Switch**<br>**Dime**<br>**Rating (A)**<br>**E min**||||**ll**<br>**nsions**<br> <br>**E**|**max**|<br>**F**|||**Switch**<br>**Body**<br>**F1**<br>**F2**||**G**<br>**J**||||**Switch**<br>**Mounting**<br>**M**<br>**N**|||**C**<br>**T**|**onnection**<br><br>**X**||
|16 to 40<br>4.13(||||105)<br>14.64(372)|||3.83(97.5)||0.59(15)|1.77(45)|2|.67(68)<br>1.92(48|||.75) 1.18(30)||2.95(75)<br>0||.59(15)|0.29(7.5)|
|63 to 80<br>4.13 (||||105)<br>14.65 (372)|||4.13 (105)||0.69 (17.5)|2.06 (52.5) 2||.99 (76)<br>2.06 (52|||.5)<br>1.38 (3.5)||3.35 (85)<br>0||.69 (17.5)|0.34 (8.75)|
## **External Selector Handles**
**==> picture [522 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
Handle Type Direction of Front Operation Direction of Right Side Operation Door Drilling Layouts<br>Ø3.07 1.57<br>Ø78 40<br>I I<br>4 Ø 0.27 0.11<br>4 Ø 7 3<br>H4X-01_ 1.42<br>36<br>0 0<br>Ø3.07<br>Ø78 Ø 1.22<br>Ø 31<br>Ø 0.88<br>With 4 Mounting Screws Ø 22.5 With Mounting Nut<br>1.45<br>37<br>H4X-02_<br>90° 90°<br>2.79 71<br>1.10 28 0.53 13.5<br>3.46 88<br>**----- End of picture text -----**<br>
**416**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches** nn:
## **UL 98 & UL 508 Enclosed Disconnect Switches**
## **Description**
Fused and non-fused enclosed Rotary Disconnect Switches from 16 to 1200A in NEMA 1, 3R, 4, 4X, 12 enclosures.
## **Features**
- UL 98 Listed for general purpose, main disconnect, or branch circuit protection up to 600Vac/dc
- UL 508 Listed for motor disconnect applications up to 600Vac
- Multiple field installed accessories enhance the enclosed disconnect switches to fit the desired application
- Lockout/tagout: Up to three[1] ⁄4˝ shank padlocks can be installed on external handles
**NEMA 1, 3R, 4 & 12 NEMA 4X NEMA 4X Stainless Steel Polycarbonate or Fiberglass**
## **Ratings:**
- Volts: 600Vac
250-600Vdc*
- Amps: 16-1200A
- Short-Circuit Current Ratings: UL 98: 25kA-200kA UL 508: 10kA-65kA
*Some non-fused disconnect switches are not rated for DC applications.
## **Specifications**
QuikShip Everyday Service ships the most common part numbers within 24 hours. Contact your Bussmann representative for details.
- Operating temperature: -20ºC to 70ºC
- 4X Plastic Enclosure Flammability Rating: Polycarbonate UL 94-5VA-0 Fiberglass UL 94-5V
## **Agency Information**
- UL 98 Listed: File E182262, Guide WIAX, WIAX7
- UL 508 Listed: File E155129, Guide NLRV, NLRV7
- cULus Listed to CSA Standard 22.2, No. 14
- cULus Listed to CSA Standard 22.2, No. 4
- Conforms with IEC 60947-3
- CE Compliant
- RoHS Compliant
## **Field Installed Accessories**
- Auxiliary contacts
- Terminal shrouds
## **Online Resources**
Visit www.cooperbussmann.com/Disconnects for:
- CAD Drawings
- Instruction Sheets
- UL Information
## **Available Bussmann Fuses**
|**Class **|**Type**|**Data Sheet #**|
|---|---|---|
|CC|LP-CC Time-Delay, Current Limiting|1023|
|CC|FNQ-R Time-Delay|1014|
|CC|KTK-R Fast-Acting|1015|
|J<br>J|LPJ Time-Delay, Current Limiting|1006 (0-60A)<br>1007 (70-600A)|
|J|With_easy_ID™open fuse indication|1062 (6-60A)|
|J||1063 (70-600A)|
|J<br>J|JKS Fast-Acting Fuses|1026 (0-60A)<br>1027 (70-600A)|
|J|DFJ High Speed Drive Fuse|1048 (0-600A)|
|L|KRP-C Time-Delay, Current Limiting|1008|
|L|KTU Fast-Acting|1010|
|L|KLU Time-Delay|1013|
**417**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 98 Enclosed Fused Disconnects—30 to 800A**
## **3-Pole UL 98 600Vac**
**Part Number System: ER 4X - 60 J 3 P B** ER **E** nclosed **R** otary Disconnect NEMA Rating 1, 3R, 4, 4X (SST), 4P (4X Plastic), 12 Amp Rating 30, 60, 100, 200, 400, 600, 800 Fuse Class J = Class J, L = Class L Number of Poles 3 = 3-Pole Handle Type P = Pistol Handle Color B = Black, R = Red
**==> picture [35 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
30-800A<br>**----- End of picture text -----**<br>
NEMA 1, 3R, 4 & 12 NEMA 4X Plastic NEMA 4X Stainless
**Part Numbers** - All part numbers provided with integral or installed lugs and a black selector handle. Order red/yellow handle by changing the suffix “B” to “R.” **UL General NEMA Enclosure Type & Part Number Purpose Fuse Amp Rating Type 1 3R 4 4X Plastic[(1)] 4X Stainless 12** 30 J ER1-30J3PB ER3R-30J3PB ER4-30J3PB ER4P-30J3PB ER4X-30J3PB ER12-30J3PB 60 J ER1-60J3PB ER3R-60J3PB ER4-60J3PB ER4P-60J3PB ER4X-60J3PB ER12-60J3PB 100 J ER1-100J3PB ER3R-100J3PB ER4-100J3PB ER4P-100J3PB ER4X-100J3PB ER12-100J3PB 200 J ER1-200J3PB ER3R-200J3PB ER4-200J3PB ER4P-200J3PB ER4X-200J3PB ER12-200J3PB 400 J ER1-400J3PB ER3R-400J3PB ER4-400J3PB ER4P-400J3PB ER4X-400J3PB ER12-400J3PB 600 J ER1-600J3PB ER3R-600J3PB ER4-600J3PB ER4P-600J3PB ER4X-600J3PB ER12-600J3PB 800 L ER1-800L3PB ER3R-800L3PB ER4-800L3PB ER4P-800L3PB ER4X-800L3PB ER12-800L3PB (1) Enclosures ≤100A are polycarbonate, flammability rating UL 94-5VA-V0, ≥200A are fiberglass, flammability rating UL 94-5V. ~~—~~ **Switch Ratings** - for wire types, ranges and tightening torques, see table on page 387 **Switch Disconnect Fuse No. of Voltage SCCR Max Hp Rating Amp Rating Switch Type Poles Vac Vdc @ Vac @ 600Vac** 30 RDF30J-3 J 20 60 RDF60J-3 J 50 250 100 RDF100J-3 J 75 600 200kA 200 RDF200J-3 J 3 150 400 RDF400J-3 J 350 600 RDF600J-3 J 600 500 800 RDF800L-3 L ~~==~~
**418**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches** ga
## **UL 98 Enclosed Fused Disconnects—30 to 800A**
## **Enclosure Weights - Lbs & Dimensions - in**
**==> picture [316 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
W<br>W W<br>A MH H B H MH C MH H<br>MW MW<br>MW<br>**----- End of picture text -----**<br>
|**Part**<br>**Number Family**|**Amp**<br>**Rating**|**Fuse**<br>**Type**|**NEMA**<br>**Enclosure Type**|**H x W x D**|**Mounting Centers H x W**|**Mounting Centers H x W**|**Mounting Centers H x W**|**Weight**<br>**Lbs**|
|---|---|---|---|---|---|---|---|---|
||||||**A**|**B**|**C**||
|ER_-30J|30<br>~~||~~|J<br>~~||~~|1,3R,4,12<br>|10x10x6<br>|8.3x8.3<br>|||15|
||||4X-SST<br>|10x10x6<br>||9.5x8.3<br>|8.3x9.5<br>|15|
||||4X-Plastic(1)<br>|12x10x6<br>||12x5.6<br>|7.64x10<br>|8|
|ER_-60J<br>~~|_|~~|60<br>~~||~~<br>~~|_|~~|J<br>~~||ee~~<br>~~|_|~~|1,3R,4,12<br>~~ee~~|12x10x6<br>~~ee~~|10.3x8.3<br>~~ee~~|~~ee~~|~~ee~~|19|
||||4X-SST<br>~~ee~~|12x10x6<br>~~ee~~|~~ee~~|11.5x8.3<br>~~ee~~|10.3x9.5<br>~~ee~~|19|
||||4X-Plastic(1)<br>~~ee~~<br>|13x13x6<br>~~ee~~<br>|~~ee~~<br>|14x7.6<br>~~ee~~<br>|9.6x12<br>~~ee~~<br>|11|
|ER_-100J<br>~~|_|~~|100<br><br>~~|_|~~|J<br>~~ee~~<br>~~|_|~~|1,3R,4,12<br>~~ee~~<br>|14x12x6<br>~~ee~~<br>|12.3x10.3<br>~~ee~~<br>|~~ee~~<br>|~~ee~~<br>|21|
||||4X-SST<br>|14x12x6<br>||13.5x10.3<br>|12.3x11.5<br>|21|
||||4X-Plastic(1)<br>|13x13x6<br>|~~—_—~~|14x7.6<br>|9.6x12<br>|12|
|ER_-200J<br>~~|_|~~<br>~~|_|~~|200<br>~~|_|SS~~<br>~~|_|~~|J<br>~~|_|SS~~<br>~~|_|~~|1,3R,4,12<br>~~SS~~|24x20x8<br>~~SS~~|22x18.1<br>~~SS~~<br>~~—_—~~|~~SS~~|~~SS~~|55|
||||4X-SST<br>~~SS~~|24x20x8<br>~~SS~~|~~SS~~<br>~~—_—~~|23.2x18.1<br>~~SS~~|22x19.3<br>~~SS~~|55|
||||4X-Plastic(1)<br>~~SS~~|27x21x10<br>~~SS~~|~~SS~~<br>~~—_—~~|25.75x14<br>~~SS~~<br>~~SS~~|~~SS~~<br>~~SS~~|39<br>~~SS~~|
|ER_-400J<br><br>~~|_|~~|400<br>~~SS~~<br>~~SSS~~<br>~~|_|~~|J<br>~~SS~~<br>~~SSS~~<br>~~|_|~~|1,3R,4,12<br>~~SS~~<br>~~SSS~~|48x36x12<br>~~SS~~<br>~~SSS~~|45.75x34.9<br>~~SS~~<br>~~—_—~~<br>~~SSS~~|~~SS~~<br>~~SSS~~<br>~~SS~~|~~SS~~<br>~~SSS~~<br>~~SS~~|188<br>~~SS~~|
||||4X-SST<br>~~SSS~~|48x36x12<br>~~SSS~~|~~—_—~~<br>~~SSS~~|46.9x34.9<br>~~SSS~~<br>~~SS~~|45.75x36.1<br>~~SSS~~<br>~~SS~~|188<br>~~SS~~|
||||4X-Plastic(1)<br>~~SSS~~|51x37x14<br>~~SSS~~|~~—_—~~<br>~~SSS~~|50.1x28.5<br>~~SSS~~<br>~~SS~~|~~SSS~~<br>~~SS~~|186<br>~~SS~~|
|ER_-600J<br>~~|_|~~|600<br>~~SSS~~<br>~~|_|~~|J<br>~~SSS~~<br>~~|_|~~|1,3R,4,12<br>~~SSS~~|48x36x12<br>~~SSS~~|45.75x34.9<br>~~SSS~~|~~SSS~~<br>~~SS~~|~~SSS~~<br>~~SS~~|216<br>~~SS~~|
||||4X-SST|48x36x12||46.9x34.9<br>~~SS~~|45.75x36.1<br>~~SS~~|216<br>~~SS~~|
||||4X-Plastic(1)|51x37x14||50.1x28.5<br>~~SS~~|~~SS~~|214<br>~~SS~~|
|ER_-800L<br>~~|_|~~|800<br>~~|_|~~|L<br>~~|_|~~|1,3R,4,12|48x36x12|45.75x34.9|~~SS~~|~~SS~~|216<br>~~SS~~|
||||4X-SST|48x36x12||46.9x34.9<br>~~SS~~|45.75x36.1<br>~~SS~~|216<br>~~SS~~|
||||4X-Plastic(1)|51x37x14||50.1x28.5<br>~~SS~~|~~SS~~|214<br>~~SS~~|
|(1) Enclosures ≤100A are polycarbonate, flammability rating UL 94-5VA-V0, ≥200A are fiberglass, flammability rating UL 94-5V.|||||||||
**Available Field-Installed Accessories -** _**Order Separately**_
**==> picture [522 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
Auxiliary Contacts - for 30 to 800 Amp Switches<br>Contact Number of Continuous Voltage Max Number of Aux Part<br>Typeype Contactsntactsactstss Amp Ratingp Rating Ratingatingtingg Ratingatingtingg Contactsntactsactstss per Switchr SwitchSwitchwitchchh Numberumbermberberr<br>NO 1 10A 600Vac 30 to 200A: 4 BAC05<br>NC 1 10A 600Vac 400 to 800A: 8 BAC06<br>Be<br>**----- End of picture text -----**<br>
**Auxiliary Contacts - for 30 to 800 Amp Switches Contact Number of Continuous Voltage Max Number of Aux Part Typeype Contactsntactsactstss Amp Ratingp Rating Ratingatingtingg Ratingatingtingg Contactsntactsactstss per Switchr SwitchSwitchwitchchh Numberumbermberberr** NO 1 10A 600Vac 30 to 200A: 4 BAC05 NC 1 10A 600Vac 400 to 800A: 8 BAC06 ~~Be~~ **Terminal Shrouds - for 200 to 800 Amp Switches** - includes terminal shroud for lineside or loadside **Switch Number Part Amp Rating of Poles Number** 200 3 TSH8-3TB 400 3 TSH9-3TB _— 600-800 3 TSH10-3TB y ~~—~~
**419**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|
|---|---|---|---|---|---|---|---|
|**3-Pole UL 98 600Vac**||||||||
|NEMA 1, 3R, 4 & 12<br>**30-100A**<br>NEMA 4X<br>**200-1200A**<br>NEMA 4X Stainless<br>**Part Number System: ER**<br>**4X**<br>**- 60**<br>**N**<br>**3**<br>**S**<br>**B**<br>ER<br>**E**nclosed**R**otary Disconnect<br>NEMA Rating<br>1, 3R, 4, 4X (SST), 4P (4X Plastic), 12<br>Amp Rating<br>30, 60, 100, 200, 400, 600, 800, 1200<br>N = Non-Fused<br>Number of Poles<br>3 = 3-Pole<br>Handle Type*<br>P = Pistol, S = Selector<br>Handle Color<br>B = Black, R = Red<br>* ≤100A = Selector only, ≥200A = Pistol only.<br>~~=~~||||||||
||||||NEMA 1, 3R, 4 & 12|NEMA 4X|NEMA 4X Stainless|
|**Part Numbers** - All part numbers provided with integral or installed lugs and a black selector handle.|||||- All part numbers provided with integral or installed lugs and a black selector handle.|||
|Order red/yellow handle by changing the suffix “B” to “R.”|||Order red/yellow handle by changing the suffix “B” to “R.”|||||
|**UL General**|||**NEMA Enclosure Type & Part Number**|||||
|**Purpose**||||||||
|**Amp Rating**<br>**1**||**3R**|**4**||**4X Plastic(1)**|**4X Stainless**|**12**|
|30<br>ER1-30N3SB||ER3R-30N3SB|ER4-30N3SB||ER4P-30N3SB|ER4X-30N3SB|ER12-30N3SB|
|60<br>ER1-60N3SB||ER3R-60N3SB|ER4-60N3SB||ER4P-60N3SB|ER4X-60N3SB|ER12-60N3SB|
|100<br>ER1-100N3SB||ER3R-100N3SB|ER4-100N3SB||ER4P-100N3SB|ER4X-100N3SB|ER12-100N3SB|
|200<br>ER1-200N3PB||ER3R-200N3PB|ER4-200N3PB||ER4P-200N3PB|ER4X-200N3PB|ER12-200N3PB|
|400<br>ER1-400N3PB||ER3R-400N3PB|ER4-400N3PB||ER4P-400N3PB|ER4X-400N3PB|ER12-400N3PB|
|600<br>ER1-600N3PB||ER3R-600N3PB|ER4-600N3PB||ER4P-600N3PB|ER4X-600N3PB|ER12-600N3PB|
|800<br>ER1-800N3PB||ER3R-800N3PB|ER4-800N3PB||ER4P-800N3PB|ER4X-800N3PB|ER12-800N3PB|
|1200<br>ER1-1200N3PB||ER3R-1200N3PB|ER4-1200N3PB||N/A|ER4X-1200N3PB|ER12-1200N3PB|
|(1) Enclosures ≤100A are polycarbonate, flammability rating UL 94-5VA-V0, ≥200A are fiberglass, flammability rating UL 94-5V.||||||||
**Switch Ratings** - for wire types, ranges and tightening torques, see table on page 405
|**Switch**|**Disconnect**|**No. of**|**Voltage**|**Voltage**|**SCCR**|**Max Hp Rating**|
|---|---|---|---|---|---|---|
|**Amp Rating**|**Switch**|**Poles**|**Vac**|**Vdc**|**@ Vac**|**@ 600Vac**|
|30|RD30-3||||100kA|25|
|60|RD60-3|||N/A||50|
|100|RD100-3||||25kA/100kA*||
|200|RD200-3|||||200|
|400|RD400-3|3|600|250|200kA|350|
|600|RD600-3||||||
|800|RD800-3|||N/A|100kA|500|
|1200|RD1200-3||||||
|* 25kA @ 600Vac, 100kA @ 480Vac.|||||||
**420**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches** gna
||**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|**UL 98 Enclosed Non-Fused Disconnects—30 to 1200A**|
|---|---|---|---|---|---|---|---|
|**Enclosure Weights - Lbs & Dimensions - in**||||||||
|||||W||||
||||W|W||||
|MW<br>MW<br>H<br>H<br>H<br>MH<br>MH<br>MH<br>**A**<br>**B**<br>**C**<br>~~Lo~~||||||||
|||||MW||||
|||||||||
|**Part**||||**Amp**<br>**NEMA**<br>**Mounting Centers H x W**||**Weight**||
|**Number Family**||||**Rating**<br>**Enclosure Type**<br>**H x W x D**<br>**A**<br>**B**<br>**C**||**Lbs**||
|ER_-30<br>ER_-60<br>ER_-100||||1,3R,4,12<br>10x8x6<br>8.3x6.3<br>30<br>4X-SST<br>10x8x6<br>9.5x6.3<br>8.3x7.5<br>4X-Plastic(1)<br>9x9x6<br>10x3.6<br>5.6x8<br>1,3R,4,12<br>10x8x6<br>8.3x6.3<br>60<br>4X-SST<br>10x8x6<br>9.5x6.3<br>8.3x7.5<br>4X-Plastic(1)<br>9x9x6<br>10x3.6<br>5.6x8<br>1,3R,4,12<br>12x10x6<br>10.3x8.3<br>100<br>4X-SST<br>12x10x6<br>11.5x8.3<br>0.3x9.5<br>4X-Plastic(1)<br>13x13x6<br>14x7.6<br>9.6x12<br>~~a~~<br>~~OO~~<br>~~OE~~||11<br>11<br>5<br>12<br>12<br>5<br>12<br>12<br>8||
|ER_-200||||1,3R,4,12<br>20x16x8<br>18.1x14.2<br>200<br>4X-SST<br>20x16x8<br>19.3x14.2<br>18.1x15.4<br>4X-Plastic(1)<br>23x17x12<br>21.5x10.1<br>~~as~~||39<br>39<br>31||
|ER_-400||||1,3R,4,12<br>36x30x8<br>33.9x28.3<br>400<br>4X-SST<br>36x30x8<br>35.1x28.3<br>33.9x29.5<br>4X-Plastic(1)<br>40x32x14<br>38.1x23.9<br>~~as~~||122<br>122<br>103||
|||||1,3R,4,12<br>48x36x12<br>45.8x34.9||209||
|ER_-600||||600<br>4X-SST<br>48x36x12<br>47x34.9<br>45.8x36.1||209||
|||||4X-Plastic(1)<br>51x37x 14<br>50.1x28.5||187||
|||||1,3R,4,12<br>48x36x12<br>45.8x34.9||211||
|ER_-800||||800<br>4X-SST<br>48x36x12<br>47x34.9<br>45.8x36.1||211||
|||||4X-Plastic(1)<br>51x37x 14<br>50.1x28.5||189||
|ER_-1200||||1200<br>1,3R,4,12<br>60x36x16<br>57.5x33.9<br>4X-SST<br>60x36x16<br>58.7x33.9<br>57.5x35.1||268<br>268||
(1) Enclosures ≤100A are polycarbonate, flammability rating UL 94-5VA-V0, ≥200A are fiberglass, flammability rating UL 94-5V.
## **Available Field-Installed Accessories -** _**Order Separately**_
|**Auxiliary Contacts - for 30 to 1200 Amp Switches**|**Auxiliary Contacts - for 30 to 1200 Amp Switches**|**Auxiliary Contacts - for 30 to 1200 Amp Switches**|**Auxiliary Contacts - for 30 to 1200 Amp Switches**|**Auxiliary Contacts - for 30 to 1200 Amp Switches**|||
|---|---|---|---|---|---|---|
|**Switch**<br>**Amp Rating**|**Contact**<br>**Type**|**Number of**<br>**Contacts**|**Continuous**<br>**Amp Rating**|**Voltage**<br>**Rating**|**Max Number of Aux**<br>**Contacts per Switch**|**Part**<br>**Number**|
|30-100|NO+ NC|1ofeach|10A|240Vac|4|BAC01|
|30-100|NC|2|10A|240Vac|4|BAC02|
|100-1200|NO+ NC|1ofeach|10.1A|125-250Vac|2|BAC03*|
|100-1200|NO+ NC|1ofeach|10.1A|125-250Vac|2|BAC04*|
|100-1200|NO+ NC|1ofeach|1A|125Vac|2|BAC11*|
|100-1200|NO + NC|1 of each|1A|125Vac|2|BAC12*|
* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.
|**Terminal Shrouds - for 200 to 800 Amp Switches**|**Terminal Shrouds - for 200 to 800 Amp Switches**|**Terminal Shrouds - for 200 to 800 Amp Switches**|**Terminal Shrouds - for 200 to 800 Amp Switches**||
|---|---|---|---|---|
|**Switch**<br>**Amp Rating**|**Number**<br>**of Poles**|**Location**<br>**on Switch**||**Part**<br>**Number**|
|30-100|3|Lineside andLoadside||TSH3-3TB|
|200A|3|Lineside||TSH4-3T|
|200A|3|Loadside||TSH4-3B|
|400A|3|Lineside||TSH5-3T|
|400A|3|Loadside||TSH5-3B|
|600A|3|Lineside or Loadside||TSH6-3TB|
|800-1200A|3|Lineside or Loadside||TSH7-3TB|
**421**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 508 Enclosed Non-Fused Disconnects—16 to 80A**
**3-/6-Pole UL 508 600Vac**
**Part Number System: ER 4X - 63 N 6 S B 16-80A** ER **E** nclosed **R** otary Disconnect NEMA Rating 1, 3R, 4, 4X (SST), 4P (4X Plastic), 12 Amp Rating 16, 25, 40, 63, 80 N = Non-Fused NEMA 1, 3R, 4 & 12 NEMA 4X Plastic NEMA 4X Stainless Number of Poles 3 = 3-Pole, 6 = 6-Pole Handle Type S = Selector Handle Color ~~— ai~~ B = Black, R = Red
**Part Numbers** - All part numbers provided with a black selector handle. Order red/yellow handle by changing the suffix “B” to “R.”
|**UL General**||||**NEMA Enclosure Type & Part Number**|**NEMA Enclosure Type & Part Number**|||
|---|---|---|---|---|---|---|---|
|**Purpose**|**No. of**|||||||
|**Amp Rating**|**Poles**|**1**|**3R**|**4**|**4X Plastic(1)**|**4X Stainless**|**12**|
|16|3|ER1-16N3SB|ER3R-16N3SB|ER4-16N3SB|ER4P-16N3SB|ER4X-16N3SB|ER12-16N3SB|
||6|ER1-16N6SB|ER3R-16N6SB|ER4-16N6SB|ER4P-16N6SB|ER4X-16N6SB|ER12-16N6SB|
|25|3|ER1-25N3SB|ER3R-25N3SB|ER4-25N3SB|ER4P-25N3SB|ER4X-25N3SB|ER12-25N3SB|
||6|ER1-25N6SB|ER3R-25N6SB|ER4-25N6SB|ER4P-25N6SB|ER4X-25N6SB|ER12-25N6SB|
|40|3|ER1-40N3SB|ER3R-40N3SB|ER4-40N3SB|ER4P-40N3SB|ER4X-40N3SB|ER12-40N3SB|
||6|ER1-40N6SB|ER3R-40N6SB|ER4-40N6SB|ER4P-40N6SB|ER4X-40N6SB|ER12-40N6SB|
|63|3|ER1-63N3SB|ER3R-63N3SB|ER4-63N3SB|ER4P-63N3SB|ER4X-63N3SB|ER12-63N3SB|
||6|ER1-63N6SB|ER3R-63N6SB|ER4-63N6SB|ER4P-63N6SB|ER4X-63N6SB|ER12-63N6SB|
|80|3|ER1-80N3SB|ER3R-80N3SB|ER4-80N3SB|ER4P-80N3SB|ER4X-80N3SB|ER12-80N3SB|
||6|ER1-80N6SB|ER3R-80N6SB|ER4-80N6SB|ER4P-80N6SB|ER4X-80N6SB|ER12-80N6SB|
|(1) Polycarbonate enclosure flammability rating UL 94-5VA-V0.|||Polycarbonate enclosure flammability rating UL 94-5VA-V0.|||||
**Switch Ratings** - for wire types, ranges and tightening torques, see table on page 413 **Switch SCCR with Max Hp Amp Disconnect Voltage Max Upstream Rating Rating Switch Vac Vdc Class J Fuse @ 600Vac** 16 RD16-3-508 65kA / 30A 10 25 RD25-3-508 65kA / 30A 20 40 RD40-3-508 600 N/A 65kA / 30A — 10kA / 60A 25 63 RD63-3-508 65kA / 60A — 50kA / 100A 40 80 RD80-3-508 65kA / 60A — 50kA / 100A 40 ~~=—~~ Note: Voltage, SCCR and Horsepower ratings are the same for 3- and 6-pole UL 508 non-fused disconnect switches.
**422**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **UL 508 Enclosed Non-Fused Disconnects—16 to 80A**
## **Enclosure Weights - Lbs & Dimensions - in**
|W<br>W<br>W<br>MW<br>MW<br>MW<br>H<br>H<br>MH<br>MH<br>**A**<br>**B**<br>**C**<br>~~—___,~~<br>~~_~~<br>|<br>|<br>i<br>~~l €~~<br>~~i~~<br>~~| |~~|W<br>W<br>W<br>MW<br>MW<br>MW<br>H<br>H<br>MH<br>MH<br>**A**<br>**B**<br>**C**<br>~~—___,~~<br>~~_~~<br>|<br>|<br>i<br>~~l €~~<br>~~i~~<br>~~| |~~|W<br>W<br>W<br>MW<br>MW<br>MW<br>H<br>H<br>MH<br>MH<br>**A**<br>**B**<br>**C**<br>~~—___,~~<br>~~_~~<br>|<br>|<br>i<br>~~l €~~<br>~~i~~<br>~~| |~~|MH|H|
|---|---|---|---|---|
||||||
|**NEMA**<br>**No. of**<br>**Switch Amp**<br>**Mounting Centers H x W**||||**Weight**|
|**Enclosure Type**<br>**Poles**<br>**Ratings**<br>**H x W x D**<br>**A**<br>**B**<br>**C**||||**Lbs**|
|1, 3R, 4, 12<br>3<br>16-80A<br>8x6x6<br>6.3x4.3<br>6<br>16-80A<br>10x8x6<br>8.3x6.3<br>4X-SST<br>3<br>16-80A<br>8x6x6<br>7.5x4.3<br>6.3x5.5<br>6<br>16-80A<br>10x8x6<br>9.5x6.3<br>8.3x7.5<br>3<br>16-63A<br>7.4x8.7x5.8<br>8x3.6<br>3.6x8<br>4X-Plastic(1)<br>80A<br>9.4x8.7x5.9<br>10x3.6<br>5.6x8<br>6<br>16-80A<br>11.4x10.7x6.3<br>12x5.6<br>7.64x10<br>(1) Polycarbonate.<br>~~_——~~<br>~~| |~~~~**—**—~~<br>~~——~~<br>~~——~~<br>~~**r**d~~<br>~~id~~||||8<br>11<br>8<br>11<br>4<br>5<br>6|
**Available Field-Installed Accessories -** _**Order Separately**_
**==> picture [165 x 74] intentionally omitted <==**
**----- Start of picture text -----**<br>
Contact<br>Type<br>NO + NC<br>NO<br>og —<br>**----- End of picture text -----**<br>
|**Auxillary Contacts**<br>**Contact**<br>**Number of**<br>**Type**<br>**Contacts**<br>NO + NC<br>1 Ea<br>NO<br>2<br>~~—~~|**Continuous**<br>**Amp Rating**<br>10A<br>10A|**Voltage**<br>**Rating**<br>240Vac<br>240Vac|**Max Number of Aux**<br>**Part**<br>**Contacts per Switch**<br>**Number**<br>4<br>BAC01<br>4<br>BAC02<br>~~~~~<br>~~fo]~~|
|---|---|---|---|
## Auxiliary Contact Configurations
|**Terminal Shrouds** - includes terminal shroud for both lineside_and_|**Terminal Shrouds** - includes terminal shroud for both lineside_and_|**Terminal Shrouds** - includes terminal shroud for both lineside_and_|**Terminal Shrouds** - includes terminal shroud for both lineside_and_|**Terminal Shrouds** - includes terminal shroud for both lineside_and_|loadside||
|---|---|---|---|---|---|---|
|**Switch**<br>**Amp Rating**|**Number**<br>**of Poles**||**Location on**<br>**Switch**|||**Part**<br>**Number**|
|16-40A|3||Lineside and Loadside|||TSH1-3TB|
|63-80A|3||Lineside and Loadside|||TSH2-3TB|
**Switched 4[th] Pole** - converts 3-pole switch to 4-pole switch **Switch Amp Part Rating Number** 16 POLE-16 25 POLE-25 40 POLE-40 ~~—_—_—_— ——~~ — ~~__ >~~ ~~**_** >~~
**423**
Visit us on the web at www.cooperbussmann.com/Disconnects
**Disconnect Switches**
## **Fused, Dead Front Disconnect Switches**
## **15149 Series**
## **Specifications**
**Description:** Fused, dead front disconnect switches
## **Ratings:**
Volts: — 600Vac Amps: — 0-30A SCCR: — 200kA RMS Sym. **Dielectric SCCR:** 2200V
## **Motor Rating:** 5Hp
## **Poles:** 2 to 3
**Agency Information:** UL Recognized, file E120756 for General Industrial installations. Guide WGEU2. CSA certified, file LR37129-6. Examined under the new proposed standard UL 1429 which imparts a stricter set of test conditions than the former program that combined the applicable portions for UL 512 (Fuse Holders) and UL 98 (Enclosed Switches).
## **Features and Benefits**
- Fuse holders in the pull-out head eliminate possibility of electric shock while changing fuse.
- Accepts Class J fuses
## **Ordering Information**
To order, specify: 15149 + number of poles. Example: 15149-2 = 2-pole device.
**==> picture [5 x 3] intentionally omitted <==**
**----- Start of picture text -----**<br>
™<br>**----- End of picture text -----**<br>
Flexibility and Convenience Make Point-of-Use Configuration Easy
Full range of open disconnect switches with versatile options and accessories that ship within 24 hours
www.cooperbussmann.com
**424**
Visit us on the web at www.cooperbussmann.com/Disconnects
## **Telecom Protection Products**
**==> picture [246 x 387] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Section Contents Page|
|Telpower compact fused disconnect switches|. . . . .426|
|Telpower miniature fused disconnect switches . . . . 427|
|Fused disconnect switches for TPA fuses|
|TP15914 4-Pole disconnect switch . . . . . . . . . . . . . . . .428|
|TP11590-4 4-Pole disconnect switch . . . . . . . . . . . . .429|
|TPA & TPA-B Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . .429|
|Fused disconnect switches for TPS fuses|
|15800 1-Pole fused disconnect switch|. . . . . . . . . . . .|430|
|TPS Fuses|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .430|
|Fused disconnect switches|
|TP158HC panel mount, rear access switch|. . . . . . . . .431|
|15100 1-Pole switch for use with TPL fuses . . . . . . . . .432|
|TPHCS Telpower high-current switch . . . . . . . . . . . .433|
|TPL Telpower 70-600A: 170Vdc fuses . . . . . . . . . . . .434|
|TPN Telpower 1-600A: 170Vdc fuses|. . . . . . . . . . . .435|
|70 Series Indicating fuses . . . . . . . . . . . . . . . . . . . . .436|
|15087 Fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . . .436|
|HLS, HLT & PCT fuse holders|. . . . . . . . . . . . . . . . . .437|
|GMT Fast acting fuses|. . . . . . . . . . . . . . . . . . . . . . . .437|
|GMT-A Fast acting fuse . . . . . . . . . . . . . . . . . . . . . . . .437|
|Telpower specialty fuses|
|7 Type Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438|
|11 Type Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438|
|24 & WER Type non-indicating, visible link fuses . . . . 438|
|74 Type Fast acting fuses . . . . . . . . . . . . . . . . . . . . . . .438|
|75 Type Cylindrical fuses with leads . . . . . . . . . . . . . . .439|
|76 Type Cylindrical fuses with leads . . . . . . . . . . . . . . .439|
|80 Type visual indicating fuses . . . . . . . . . . . . . . . . . . .439|
**----- End of picture text -----**<br>
Scan this tag to get the latest product information for Telecom Protection Products.
**425**
**Telecom Protection Products**
## **Telepower Compact Fused Disconnect Switches**
## **TPC & TPCDS**
**Specifications Descriptions:** — **TPC:** Telepower compact currentlimiting fuses. — **TPCDS:** Telepower compact fused disconnect switch available in
two disconnect switch profiles in addition to a variety of terminal styles. Recommended 0.75” center-to-center product spacing.
**Dimensions:** See Data Sheet 5023.
## **Ratings:**
Volts: — 80Vdc
- Amps: — 3-125A (See Catalog Numbers table for details) IR: — 100kA
**Agency Information:** CE, UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout. Recognized to US and Canadian requirements under the component recognition program of Underwriters Laboratories Inc. Files E219046 and E56412.
## **Catalog Numbers**
|**TPCS disconnect switch**|**TPCS disconnect switch**|**TPC Current-Limiting Fuse**|**TPC Current-Limiting Fuse**|
|---|---|---|---|
|**Catalog**|**Amp**|**Catalog**|**Amp**|
|**Numbers**|**Range**|**Numbers**|**Rating**|
|TPCDS-BBE-1|3-125|TPC-3|3|
|TPCDS-BBE-2<br>3-125<br>TPC-4<br>4<br>~~ooo~~||||
|TPCDS-BBE-3|3-125|TPC-5|5|
|TPCDS-BBM-1|3-125|TPC-6|6|
|TPCDS-BBM-2|3-125|TPC-7|7|
|TPCDS-BBM-3|3-125|TPC-8|8|
|TPCDS-BSE-1|3-125|TPC-10|10|
|TPCDS-BSE-2|3-125|TPC-12|12|
|TPCDS-BSE-3|3-125|TPC-15|15|
|TPCDS-BSM-1|3-125|TPC-20|20|
|TPCDS-BSM-2|3-125|TPC-25|25|
|TPCDS-BSM-3|3-125|TPC-30|30|
|TPCDS-SSE-1|3-125|TPC-40|40|
|TPCDS-SSE-2|3-125|TPC-50|50|
|TPCDS-SSE-3|3-125|TPC-60|60|
|TPCDS-SSM-1|3-125|TPC-75|75|
|TPCDS-SSM-2|3-125|TPC-90|90|
|TPCDS-SSM-3|3-125|TPC-100|100|
|TPCDS-D-BC1*|3-125|TPC-125|125|
|TPCDS-D-BC2*|3-125|||
|TPCDS-D-CC1*|3-125|||
|TPCDS-D-SEC1*|3-125|||
|TPCDS-D-SEC2*|3-125|||
|TPCDS-D-SMC1*|3-125|||
|TPCDS-D-SMC2*|3-125|||
*Not investigated to Canadian Requirements.
**Flammability Ratings:** Fuse UL 94V0, 170°C RTI, Housing UL 94V0, 120°C RTI.
## **Features and Benefits**
- Highest interrupting rating (100kA) available and complete system coordination for DC circuit protection for compact footprint providing a superior protection solution for replacement of existing DC telecom circuit breakers
- AmpColor ID™ System makes fuse replacement easy
- Local and remote open fuse indication. Local alarm indication provided by LED on TPC fuse
- Remote alarm terminal available in three positions common to DC circuit protection devices
## **Typical Applications**
- Telecommunications DC power circuit protection
- Replacement of DC telecom circuit breakers
- Applications where venting of arc or molten metals and gases during opening would pose a problem to surrounding devices
**Data Sheet: 5023**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**426**
**Telecom Protection Products**
## **Telepower Miniature Fused Disconnect Switches**
**==> picture [41 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
TPM &<br>**----- End of picture text -----**<br>
## **TPMDS**
**Specifications Description: — TPM:** Telepower miniature currentlimiting fuses. **— TPMDS:** Telepower miniature fused disconnect switch.
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|**Catalog Numbers**||
|---|---|---|---|
|**Catalog**<br>**Numbers**<br>**Description**<br>a<br>71<br>f<br>'<br>,<br>-<br>~~b~~|||**Amp**<br>**Rating**|
||TPM-3|Fuse|3|
|%<br>Ha<br>i<br>{lif<br>'|TPM-4<br>Fuse<br>4<br>TPM-5<br>Fuse<br>5<br>TPM-6<br>Fuse<br>6<br>~~ee~~|||
||TPM-7|Fuse|7|
||TPM-8<br>TPM-10|Fuse<br>Fuse|8<br>10|
||TPM-12|Fuse|12|
||TPM-15<br>TPM-20<br>TPM-25|Fuse<br>Fuse<br>Fuse|15<br>20<br>25|
||TPM-30|Fuse|30|
||TPMDS-E<br>TPMDS-M|Disconnect, English hardware<br>Disconnect, Metric hardware|3-30<br>3-30|
**Dimensions:** See Data Sheet 5022.
## **Ratings:**
Volts: — 80Vdc Amps: — 3-30A
## **TPM Alarm Schematic**
IR: — 20kA
**Agency Information:** CE, UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout. Recognized to US and Canadian requirements under the component recognition program of Underwriters Laboratories Inc. Files E219046 and E56412.
**Flammability Ratings:** Fuse UL 94V0, 170ºC RTI; Switch UL 94V0, 140ºC RTI.
## **Features and Benefits**
- Smallest and most versatile fused disconnect switch available allowing for assembly into 1 U (1.75˝/44.5mm) panel. Easy to connect; Load:[1] ⁄4˝ quick-connect or bolted connection with 10-32 (M5) captive nut, Line:[1] ⁄4˝ quick-connect or screw connection with clearance hole for #10 (M5) bolt.
- AmpColor ID™ System makes fuse replacement easy
- Switch design provides for easy panel mounting by single captive 4-40 (M3) nut and panel notch integral to switch footprint.
- Complete system coordination capability with local and remote open fuse indication. Local alarm indication provided by LED on TPM fuse (maximum alarm circuit current: 20mA)
## **Typical Applications**
• Telecommunications DC power circuit protection
- Applications with restricted space, or mounting in 1 U panels
## **NOTES:**
1. The resistance, R, must be provided by the end-user to limit the alarm output current to a maximum of 20mA. The value, R, should be calculated using the system voltage value.
• If remote alarm functionality is not required, the END-USER CIRCUITRY must still be supplied to provide a resistive path to the return for the local alarm to properly function.
2. The fuse is polarized to maintain proper orientation with the switch housing. The line and load terminals are identified on the switch housing.
**Data Sheet: 5022**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**427**
**Telecom Protection Products**
## **Fused Disconnect Switches for TPA Fuses**
## **TP15914**
**Specifications Description:** Modular 4-pole 4 F 77 4 disconnect switch sie5 for TPA Series fuses — 4-poles a ipf — r per module up to sparea Hii. four modules ganged together. | = Features open fuse indication and fuse presence indication along with fuse orientation rejection feature.
**Dimensions:** See Dimensions illustrations.
## **Dimensions mm - (in)**
**==> picture [192 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.745<br>-32 Thread) L189 MOUNTING<br>fe c al 0.284 rorOM<br>fe op t nal<br>Y S E<br>anol 1.5 l e-eh L e?t e 1Sae y] p // 38.10 1.5<br>oS SS -4<br>——— —<br>DIA.<br>0.215 5.46 0.625 90.58<br>3.57<br>108.48<br>4.27<br>**----- End of picture text -----**<br>
## **Ratings:**
Volts: — 145Vdc
Amps: — 50A per pole
**Agency Information:** CE, UL Recognized as a disconnect switch for interruption of load current by means of withdrawing the fuse carrier. UL Recognized as a component for telecommunication power distribution equipment (UL category QPQYZ), UL Recognized fuses for branch circuit protection, CSA component acceptance for the system. UL Recognized, Guide JFHR2, File E56412., CSA Certified, Class 1422-30, File 53787. **Flammability Rating:** UL 94V0, 140°C.
## **Features and Benefits**
- Totally enclosed module directly connects to busbar for reduced external wiring—per pole and easy installation with front access load and line connection standard— double lug load connections 8 AWG wire
- LED alarm signaling (LED current 30mA max)
- Remote alarm with alarm test probe point to allow on-site checking of alarm circuitry
**==> picture [49 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
TOP<br>-——\"<br>\f \f<br>g<br>ee<br>Cy<br>76.07<br>3.0 || ES<br>**----- End of picture text -----**<br>
## **Accessories**
- Spare fuse holders: Catalog Numbers 5TPH and TPSFH-A
- Bi-polar LED provides capability for both –48Vdc and +24Vdc applications
## **Typical Applications**
- Telecommunications DC power circuit protection
## **Catalog Numbers**
**Catalog Numbers Hardware** TP15914 English TP15914-1 Metric
**Data Sheet: 5011**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**428**
**Telecom Protection Products**
## **Fused Disconnect Switches for TPA Fuses**
## **TP15900-4**
**Specifications Description:** 4-pole disconnect switch for use with Telepower fuses Type TPA & TPA-B.
**Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts: — 145Vdc (40A) — 80Vdc (50A)
Amps: — 40A@145Vdc — 50A@80Vdc
**Agency Information:** CE, UL Recognized File E97649 as a disconnect switch for interruption of load current by means of withdrawing the fuse carrier. UL Recognized as a component for telecommunication power distribution equipment (UL category QPQY2). UL Recognized fuses for branch circuit protection. CSA Component Acceptance for the system.
**Flammability Rating:** UL 94V0, 140°C.
## **Features and Benefits**
- Ease of installation - connection directly to busbar, reduces external wiring per pole. Rear accessibility for line and load terminations
- LED alarm signaling (LED current 30mA max)
- Local and remote open-fuse indication along with fuse orientation rejection feature and fuse presence indication
- Alarm test probe point, to allow on-site checking of alarm circuitry
## **Typical Applications**
- Telecommunications DC power circuit protection
## **Catalog Numbers**
**Catalog Numbers Description** TP15900-4 4-Pole common disconnect switch
TP15900-41 4-Pole common disconnect switch w/ Split Alarm, Split Line
## **TPA & TPA-B**
## **Specifications**
**Description:** DC power distribution indicating fuses.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 170Vdc TPA — 65Vdc TPA-B
Amps: — 3-50A TPA — 20-30A TPA-B
- IR: — 100kA TPA — 20kA TPA-B
**Agency Information:** CE, UL Recognized, Guide JFHR2, File E56412, CSA Certified, Class 1422-30, File 53787.
## **Features and Benefits**
- Indication pin provides for local and remote indication when used with Bussmann TP15900-4 and TP15914 disconnect switches
- Patented “orange ring” fuse orientation features assures correct fuse position
- The UL Recognized ratings and current-limiting capability make this fuse ideal for cable protection on existing DC power distribution systems
- A unique blue label is used on all Telepower fuses to designate their DC capability
## **Typical Applications**
- Telecommunications DC power circuit protection
## **Catalog Numbers (Amps)**
|**Catalog**|**Amp**|**Catalog**|**Amp**|
|---|---|---|---|
|**Numbers**<br>TPA-3|**Rating**<br>3|**Numbers**<br>TPA-30|**Rating**<br>30|
|TPA-5<br>TPA-10|5<br>10|TPA-40<br>TPA-50|40<br>50|
|TPA-15|15|TPA-B-20|20|
|TPA-20<br>TPA-25|20<br>25|TPA-B-25<br>TPA-B-30|25<br>30|
## **Dimensions - mm (in)**
## **Dimensions - mm (in)**
## **Accessories**
- Spare fuse holders: 5 position holder; 5TPH; 6 position holder; TPSFH-AS
- Use with fused disconnect switches TP15900-4, TP15914
**==> picture [4 x 1] intentionally omitted <==**
**----- Start of picture text -----**<br>
-<br>**----- End of picture text -----**<br>
## **Accessories**
- Spare fuse holders: Catalog Numbers 5TPH and TPSFH-AS.
**Data Sheet: 5001**
**Data Sheet: 5012**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**429**
**Telecom Protection Products**
## **Fused Disconnect Switches for TPS Fuses**
## **15800**
## **Specifications Description:**
Fused disconnect switch for use only with the following fuses; Main: Telepower TPS 3 to 70 Amp, Alarm: Bussmann GMT-A only (page 399). Recommend GMT-X Cover (page 437). **Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 60Vdc Amps: — 3-70A SCCR: — 100kA
**Agency Information:** CE, UL Recognized, Guide QPQY2, File E97649.
**Flammability Rating:** UL 94V0, 150°C.
## **Features and Benefits**
- Alarm output with wire wrap terminal or connection to 0.063” thick common alarm bus
- Spare alarm and power fuse compartment
- Mounting hardware included
## **Typical Applications:**
- Telecommunications DC power circuit protection
## **Catalog Numbers**
**Catalog Numbers Access Panel Mounting** 15800-R-200 Rear 15800-F-200 Front
## **Dimensions - in (mm)**
## **TPS**
**Specifications Description:** DC power distribution non-indicating fuses specifically designed to meet the unique needs
of DC power distribution systems. For use with Bussmann fused disconnect switch 15800.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 170Vdc
Amps: — 1-70A
IR: — 100kA
**Agency Information:** CE, UL Recognized, Guide JFHR2, File E56412.
## **Features/Benefits**
- The UL Recognized ratings and current-limiting capability make this fuse ideal for cable protection on existing DC power distribution systems
- A unique blue label is used on all Telepower fuses to designate their DC capability
- Printed circuit board variations available
## **Typical Applications**
- Telecommunications DC power circuit protection
- Applications requiring printed circuit board mounting
## **Catalog Numbers (Amps)**
|TPS-1<br>TPS-1L|TPS-6L<br>TPS-10|TPS-30<br>TPS-30L|TPS-50V<br>TPS-60|
|---|---|---|---|
|TPS-2|TPS-10L|TPS-35|TPS-60L|
|TPS-2L|TPS-15|TPS-35L|TPS-70|
|TPS-3|TPS-15L|TPS-40|TPS-70L|
|TPS-3L|TPS-20|TPS-40L|TPS-70LB|
|TPS-5|TPS-20L|TPS-40V||
|TPS-5L|TPS-25|TPS-50||
|TPS-6<br>TPS-25L<br>TPS-50L<br>~~ee~~||||
## **Dimensions - in (mm)**
**==> picture [16 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
72 lb-in<br>**----- End of picture text -----**<br>
## **Accessories**
- Spare fuse holder: TPSFH-AS, see page 510.
## **Accessories**
- Spare fuse holders: Catalog Numbers TPSFH-AS (TPS fuses) and TPSFH-T (GMT fuses).
**Data Sheet: 5002**
**Data Sheet: 5009**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**430**
**Telecom Protection Products** ED
## **Fused Disconnect Switches**
## **TP158HC**
## **Specifications**
**Description:** Panel mount, rear access high amp version of Bussmann 15800 series fused disconnect switch for use only with the following fuses; Main: Telepower TPL-B 70-250 Amps, Alarm: Bussmann GMT-A. **Dimensions:** See Data Sheet 5021.
## **Application Notes**
- The line connection uses a[1] ⁄4-20 bolt (metric – M6X1) that threads into the line terminal. The line terminal is designed with a float of ±0.02˝ (±0.50mm) to allow for variation in the distance between the TP158HC mounting flange and the line busbar (see Dimensions). Equipment should be designed to eliminate any relative movement between the TP158HC mounting flange and the line busbar.
- The alarm circuit is not intended for precharging of capacitive circuits. Alarm circuit current 1A maximum.
## **Ratings:**
Volts: — 80Vdc Amps: — 70-250A SCCR: — 100kA
**Agency Information:** UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout. Guide QPQY2, File E97649.
## **Easy Fuse Replacement**
**Flammability Rating:** UL 94V0, 150°C.
## **Features and Benefits**
- Similar profile, mounting method, and backplane configuration as 15800 Series. The TP158HC can be installed into existing 15800 Series panels using the space of two 15800 disconnects
- Innovative new fuse pullout design eliminates need for tools to replace the Telepower type TPL-B fuse
- Alarm output with wire wrap terminal or connection to 0.063 inch (1.6mm) thick common alarm bus
- Hardware included: Load: washer, split lockwasher, and 5 ⁄16 - 18 nut (metric-M8 x 1.25)
## **Typical Applications:**
- Telecommunications DC power circuit protection
## **Catalog Numbers**
**Catalog Numbers Hardware** TP158HC English TP158HC-M Metric
## **Accessories**
- Spare fuse holders: TPSFH-LB (TPL-B fuses) and TPSFH-T (GMT fuses).
**Data Sheet: 5021**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**431**
**Telecom Protection Products**
## **Fused Disconnect Switches**
## **15100**
**Specifications Description:** Fused disconnect system for use with Telepower fuses Type TPL. **Dimensions:** See Dimensions illustrations.
**Ratings:**
Volts: — 60Vdc Amps: — 70-800A
SCCR: — 100kA
**Agency Information:** CE, UL Recognized, Guide QPQY2, File E97649.
## **Features and Benefits**
- Single-pole fusible disconnect switch for primary DC power distribution
- Robust housing and terminal construction for demanding applications
- Panel mounting
- Easily connected to line or load bus
## **Typical Applications**
- Telecommunications DC power circuit protection
## **Catalog Numbers**
**Catalog For Use With Numbers TPL Series Fuses** 15100-401 70-400A 15100-601 300-800A
**Dimensions - in (mm)**
**==> picture [165 x 273] intentionally omitted <==**
**----- Start of picture text -----**<br>
6 [.75]["]<br>(171.45mm)<br>a<br>3" 4"<br>(76.2mm) (101.6mm)<br>0.27" (6.75mm) Dia. Hole with 0.5" (12.7mm)<br>Dia. x 0.16" (3.97mm) Deep C'bore (4 Holes)<br>5.75"<br>(146.05mm)<br>3.63"<br>(92.07mm)<br>2.75"<br>(69.85mm)<br>7.13"<br>(181.10mm)<br>1.31 an " 2.63"<br>(33.33mm) (66.67mm)<br>5.25"<br>(133.35mm)<br>**----- End of picture text -----**<br>
**Data Sheet: 5003**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**432**
**Telecom Protection Products** yy yyy
## **Telpower High-current Switch**
## **Catalog Numbers – Switches (Pullout and Base)**
## **TPHCS**
|**Catalog**|**Hardware/**|**Fuse**|**Amp**|
|---|---|---|---|
|**Numbers**<br>TPHCS250-M<br>TPHCS250-E|**Option**<br>Metric<br>English|**Series**<br>TPL-B<br>TPL-B|**Rating**<br>70-250<br>70-250|
|TPHCS250-ML<br>TPHCS250-EL<br>TPHCS250-MAV|Metric, LED<br>English, LED<br>Metric, Alarm|TPL-B<br>TPL-B<br>TPL-B|70-250<br>70-250<br>70-250|
|TPHCS250-EAV<br>TPHCS800-M<br>TPHCS800-E|English, Alarm<br>Metric<br>English|TPL-B<br>TPL-C or TPH<br>TPL-C or TPH|70-250<br>300-800<br>300-800|
|TPHCS800-ML<br>TPHCS800-EL<br>TPHCS800-MAV<br>TPHCS800-EAV|Metric, LED<br>English, LED<br>Metric, Alarm<br>English, Alarm|TPL-C or TPH<br>TPL-C or TPH<br>TPL-C or TPH<br>TPL-C or TPH|300-800<br>300-800<br>300-800<br>300-800|
**Specifications Description:** High current switch for use with Telepower fuses Type TPL-B, TPL-C and TPH. Available as complete switch or pullout. **TPHCS800-MAV (shown)** Base may be purchased separately.
## **Catalog Numbers – Components**
**Dimensions:** See Dimensions illustrations.
## **Construction:**
|**Catalog**|**Description**|**Fuse**|**Amp**|
|---|---|---|---|
|**Numbers**<br>TPHCS250-P|**Rating/Hardware/Option**<br>Pullout only–250A|**Series**<br>TPL-B|**Rating**<br>70-250|
|TPHCS800-P<br>TPHCS-B-M|Pullout only–800A<br>Base only, Metric|TPL-C or TPH<br>—|300-800<br>800 Max|
|TPHCS-B-E<br>TPHCS-B-ML|Base only, English<br>Base only, Metric, LED|—<br>—|800 Max<br>800 Max|
|TPHCS-B-EL<br>TPHCS-B-MAV|Base only, English, LED<br>Base only, Metric, Alarm|—<br>—|800 Max<br>800 Max|
|TPHCS-B-EAV|Base only, English, Alarm|—|800 Max|
## **Ratings:**
Volts:— 80Vdc Amps:— 70-800A SCCR: — 100kA
**Agency Information:** UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse carrier. UL Recognized to meet the requirements for Canadian Standards.
## **Dimensions - mm (in)**
**==> picture [503 x 333] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø 7.62<br>Standards. (0.300)<br>41.02 Type. 4<br>(1.615) L<br>Features and Benefits<br>• Innovative design eliminates need for tools to replace the L 66.4<br>Telepower [[™]] Type TPL-B, TPL-C or TPH fuse (2.62)<br>iE eeAy<br>• Easy to install–captive fasteners allow for direct busbar L<br>mounting (bolts not included). Standard [[1]] ⁄4” male quick-4” male quick-” male quick-<br>connect terminal for effortless remote alarm connection. 12.7 122.43<br>22.2 (0.50) 8.8 (4.820)<br>• Optional new electronic alarm eliminates need for parallel (0.88) ip (0.34) [Fieals]<br>indicating fuses while providing local and remote open- L 25.9<br>(1.02) 17.3<br>fuse indications (maximum remote alarm current: 20mA); i 4 a L L Py (0.68)<br>Bipolar alarm: designed for both Central Office and Radio L<br>applications, Local LED alarm indication for 100.5 REF L<br>ease-of-viewing. (3.96)<br>• Fuse presence window allows for easy viewing of installed 74.6 13.2<br>(2.94)<br>fuse amp rating (0.52)<br>Typical Applications<br>• Telecommunications DC power circuit protection A a == 105.2<br>• Compact design is ideal for today’s high power, See table for part (4.14)<br>number format 139.7<br>high-density cabinets (5.50)<br>Threaded Insert, 4 Places<br>24.8 REF M8x1.25 (-M Series) 5/16-18 (-E Series)<br>Recommended Torque 15N [• ] m (11 Ft-lb)<br>(0.98)<br>L Tin-Plated<br>Copper<br>L Terminals<br>LOH oF it +o iy<br>16.76<br>(0.660)<br>39.2 REF 61.47<br>(1.54) (2.420)<br>L<br>L L<br>L<br>L L<br>L L<br>L L<br>L L L L<br>L<br>L<br>L<br>L<br>L L<br>L<br>L L<br>L L<br>L<br>L<br>**----- End of picture text -----**<br>
## **Features and Benefits**
- Innovative design eliminates need for tools to replace the Telepower[[™]] Type TPL-B, TPL-C or TPH fuse
- Easy to install–captive fasteners allow for direct busbar mounting (bolts not included). Standard[[1]] ⁄4” male quick-4” male quick-” male quickconnect terminal for effortless remote alarm connection.
- Fuse presence window allows for easy viewing of installed fuse amp rating
## **Typical Applications**
- Telecommunications DC power circuit protection
- Compact design is ideal for today’s high power, high-density cabinets
## **NOTES:**
1. TPHCS250 and TPHCS800 pullouts and bases are the same with exception to the type of fuse, TPL-B, TPL-C or TPH the pullout will carry.
2. Plastic rated UL 94V0, 140ºC RTI.
**Data Sheet: 5020**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**433**
**Telecom Protection Products**
## **Telpower 70-600A: 170Vdc Fuses**
## **TPL**
## **Specifications**
**Description:** DC power distribution fuses for use with Telepower 15100, 15200, TP158HC and TPHCS disconnect systems. For replacement of Bussmann UBO fuses a TPL-TA adapter kit is necessary. **Dimensions:** See Dimensions illustrations.
**Ratings:**
Volts: — 170Vdc Amps: — 70-800A
IR: — 100kA
**Agency Information:** CE, UL Recognized Guide JFHR2, File E56412 Bellcore.
## **Features and Benefits**
- Current-limiting capability designed for DC power distribution systems
- Recognized branch circuit protection
- Complete system coordination capability
- Energy savings with low watts loss, low operating temperatures, and minimum I[2] t levels
## **Dimensions - in (mm)**
**==> picture [233 x 244] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.66"<br>(67.5mm)<br>2.19"<br>(55.6mm)<br>1.91"<br>(48.4mm)<br>1.16" 1.0"<br>(29.4mm) (25.4mm)<br>BUSS —_ aN<br>0.75"<br>(19.1mm)<br>TPL–B L<br>0.33" 0.19"<br>o l la (8.3mm) (4.8mm) ©<br>TPL-BA, TPL-BD, TPL-BF , TPL-BH, TPL-BK, and TPL-BL<br>3.50"<br>(88.9mm)<br>2.44"<br>(61.9mm)<br>1.25" 1.50"<br>(31.8mm) (38.1mm)<br>BUSS<br>_ 1.00" t<br>(25.4mm)<br>TPL – CZ<br>0.41"<br>(10.3mm) 0.2 5 "<br>= (6.4mm) ©<br>**----- End of picture text -----**<br>
## **TPL-CN, TPL-CR, TPL-CV and TPL-CZ**
## **Typical Applications**
- Telecommunications power circuit protection
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|
|---|---|
|**Catalog**|**Amp**|
|**Numbers**|**Rating**|
|TPL-BA|70|
|TPL-BB|80|
|TPL-BC|90|
|TPL-BD|100|
|TPL-BE|125|
|TPL-BF|150|
|TPL-BG|175|
|TPL-BH|200|
|TPL-BK|225|
|TPL-BL|250|
|TPL-CN|300|
|TPL-CO|350|
|TPL-CR|400|
|TPL-CU|450|
|TPL-CV|500|
|TPL-CZ|600|
|TPL-CZH|800|
## **Accessories**
- Spare fuse holders: TPSFH-LB (for TPL-B fuses) TPSFH-LC (for TPL-C fuses)
**Data Sheet: 5005**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**434**
**Telecom Protection Products** gt ~~eee~~ Neer errr **Telpower 1-600A, 170Vdc Fuses**
## **TPN**
**Specifications Description:** Currentlimiting DC power distribution fuses. The TPN fuse series is dimensionally similar to Class R fuses making it easy to use standard Class R fuse blocks.
**Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts: — 170Vdc
Amps: — 1-600A
IR: — 100kA
**Agency Information:** UL Recognized, Guide JFHR2, File E56412.
## **Features/Benefits**
- Current-limiting capability designed for DC power distribution systems
- Recognized branch circuit protection
- Complete system coordination capability
- Energy savings with low watts loss, low operating temperatures, and minimum I[2] t levels
## **Typical Applications**
- Telecommunications power circuit protection
## **Catalog Numbers (Amps)**
|TPN-1<br>TPN-3<br>TPN-5|TPN-45<br>TPN-50<br>TPN-60|TPN-200<br>TPN-225<br>TPN-250|
|---|---|---|
|TPN-6|TPN-70|TPN-300|
|TPN-10|TPN-80|TPN-350|
|TPN-15|TPN-90|TPN-400|
|TPN-20|TPN-100|TPN-450|
|TPN-25|TPN-110|TPN-500|
|TPN-30|TPN-125|TPN-600|
|TPN-35|TPN-150||
|TPN-40|TPN-175||
## **Dimensions - in (mm)**
**==> picture [182 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.56"<br>2" (14.3mm)<br>(50.8mm)<br>~<br>1A to 30A<br>0.81"<br>3" (20.6mm)<br>(76.2mm)<br>35A to 60A<br>5.88"<br>(149.2mm)<br>1.00"<br>Rr (25.4mm)<br>70A to 100A<br>7.13"<br>(181.0mm)<br>1.50"<br>(38.1mm)<br>REL<br>110A to 200A<br>8.63"<br>(219.1mm)<br>2.00"<br>(50.8mm)<br>225A to 400A In]| A T<br>10.38"<br>(263.5mm)<br>2.50"<br>(63.5mm)<br>450A to 600A<br>**----- End of picture text -----**<br>
## **Accessories**
- Spare fuse holders:TPSFH-N30 (for TPN 1-30) TPSFH-N60 (for TPN 35-60)
## **Recommended Class R Fuse Blocks**
|||**Catalog**|
|---|---|---|
|**Amps**|**Poles**|**Number**|
|1-30|1|R25030-1CR|
|1-30|2|R25030-2CR|
|1-30|3|R25030-3CR|
|35-60|1|R25060-1CR|
|35-60|2|R25060-2CR|
|35-60|3|R25060-3CR|
|70-100|1|R25100-1CR|
|70-100|2|R25100-2CR|
|70-100|3|R25100-3CR|
|110-200|1|R25200-1CR|
|110-200|3|R25200-3CR|
|225-400|1|R25400-1CR|
|225-400|3|R25400-3CR|
|450-600|1|R25600-1CR|
|450-600|3|R25600-3CR|
**Data Sheet: 5006**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**435**
**Telecom Protection Products**
## **Indicating Fuses and Holders**
## **70 Series Fuses**
**15087 Fuse Holder Specifications Description:** Fuse holder for 70 Series fuses. **Ratings:** Volts: — 300Vdc Amps: — 12A **Agency Information:** CE, UL Recognized, Guide IZLT2, File E14853. ~~i~~ **Flammability Rating:** UL 94V0.
## **Specifications**
**Description:** Indicating type fuse. **Ratings:**
Volts:— 125Vac/300Vdc Amps:—[1] ⁄10-10A
IR:— 1kA @ 300Vdc
**Agency Information:** CE, UL Recognized, Guide JDYX2, File E19180 Bellcore.
## **Catalog Numbers**
||||**Lucent**||
|---|---|---|---|---|
|**Catalog**<br>**Numbers**|**Amp**<br>**Rating**|**Color**<br>**Code**|**Comcode**<br>**Ref. No.**|**Code/**<br>**List No.**|
|70P-1⁄10A*|1⁄10|Gray/Wh|100203413|KS23751-L10|
|70R-15⁄100A*|15⁄100|Red/Wh|101384550|KS23751-L11|
|70E-18⁄100A*<br>70X-2⁄10A|18⁄100<br>2⁄10|Yellow<br>Black|100203363<br>—|KS23751-L5<br>—|
|70F-1⁄4A*|1⁄4|Violet|100203371|KS23751-L6|
|70K-1⁄4A*|1⁄4|Violet/Wh|100203405|KS23751-L9|
|70G-1⁄2A*<br>70H-3⁄4A*|1⁄2<br>3⁄4|Red<br>Brown|100203389<br>100203397|KS23751-L7<br>KS23751-L8|
|70I-1A<br>70A-11⁄3A*†|1<br>11⁄3|Pink<br>White|—<br>100203322|—<br>KS23751-L1|
|70B-2A*<br>70C-3A*|2<br>3|Orange<br>Blue|100203330<br>100203348|KS23751-L2<br>KS23751-L3|
|70J-31⁄2A|31⁄2|Black/Wh|—|—|
|70D-5A*<br>70L-6A|5<br>6|Grn/Blk<br>Grn/Wh|100203355<br>—|KS23751-L4<br>—|
|70M-8A|8|Brown/Wh|—|—|
|70N-10A<br>GKB-10A|10<br>10|Violet/Yel<br>Violet/Yel|—<br>—|—<br>—|
|72A Plastic CaseDummy<br>72B Blister PackDummy|72A Plastic CaseDummy<br>72B Blister PackDummy|—<br>—|100203421<br>103757977|—<br>—|
## **Features and Benefits**
- Panel mount fuse holder for 70 Type fuses supplied with two screws
- Remote alarm capability
## **Typical Applications**
- Telecommunications DC power circuit protection
## **Catalog Number — 15087**
## **Accessories**
**Description:** Optional color code eyelets used with fuse holder to indicate fuse amp rating.
## **Eyelet Catalog Numbers**
|**Catalog**|**Amp**|**Color**|
|---|---|---|
|**Numbers**|**Indication**|**Code**|
|1A1706-01|18⁄100|Yellow|
|1A1706-02<br>1A1706-03<br>1A1706-04<br>1A1706-05|2⁄10<br>1⁄4<br>1⁄4<br>1⁄2|Black<br>Violet<br>Violet/White<br>Red|
|1A1706-06|3⁄4|Brown|
|1A1706-07|1|Pink|
|1A1706-08|1<br>1⁄3|White|
|1A1706-09|2|Orange|
|1A1706-10|3|Blue|
|1A1706-11|5|Green/Black|
|1A1706-12|6|Green/White|
|1A1706-13|8|Brown/White|
|1A1706-14|10|Violet/Yellow|
|1A1706-15|1⁄10|Gray/White|
|1A1706-16|3<br>1⁄2|Black/White|
|1A1706-17|15⁄100|Red/White|
*Product designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, December 1988. †No longer UL Recognized.
**Data Sheet: 5007**
**Data Sheet: 5007**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**436**
**Telecom Protection Products**
## **Indicating Fuses and Holders**
## **HLS, HLT, PCT**
## **Specifications**
**Description:** Fuse holders for GMT Type indicating fuses. **Poles:** 01 to 25. **Ratings:**
Volts: — 60Vdc/125Vac
## **Agency Information:**
CE, UL Recognized, Guide IZLT2, File E14853, 15A (60Vdc).
**Flammability Rating:** UL 94V0.
## **GMT**
## **Specifications**
**Description:** Fast-acting fuses for use in HLT, HLS, and PCT fuse holders.
## **Ratings:**
Volts: — 60Vdc/125Vac
Amps: —[18] ⁄100-15A
IR: — 450A@60Vdc — 300A@125Vac
**Agency Information:** CE, UL Recognized, Guide JFHR2, File E56412.
**Flammability Rating:** UL 94V0.
## **Features and Benefits**
- Local and remote indication capability
## **Features and Benefits**
- Multiple configurations provide application flexibility
- Compact size saves space
**==> picture [104 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
GMT - Dummy GMT - A (Alarm)<br>**----- End of picture text -----**<br>
## **Typical Applications**
- Telecommunications DC power circuit protection
## **Catalog Numbers**
|**Catalog Numbers**<br>PCT<br>HLS<br>HLT|**Catalog Numbers**|**Poles**<br>1<br>See Build-A-Code<br>See Build-A-Code|
|---|---|---|
**==> picture [223 x 265] intentionally omitted <==**
**----- Start of picture text -----**<br>
Multiple Fuse holders with bus bars<br>Ordering Information— Catalog No.<br>Body Style HL T<br> HLS (No flanges) T ermination Location<br>L Sa R Cpa<br>No. of Poles 01 thru 25 (Left only) (Right only)<br>(Min. of 2 poles required for bus bars)<br>B Ba<br>T ype of bus bars used*** “Ty 7 (Both ends)<br>B1*, B2, B3,<br>B4, B5, SL** (Short Leads .135")<br>ML** (Medium Leads .250")<br> ** Not available with bus bars<br> Bus Bar Position<br>P1† P2<br>S B1 aw B2 B3 (Inside— Both Sides) as (Outside— Both Sides)<br>(Angle Bar Only)* r Only) (“U” Bar Only)<br>: P3 S P4 =<br>(Outside— (Outside—<br>Right Only) Left Only)<br>a4<br>B4 B5<br>(Angle & “L” Bars) (“L” & “U” Bars)<br> *Angle Bar mounts on common or center terminals only.<br>**SL Version is not available with bus bars.<br>†Minimum of 4 Poles Required.<br>***.38 max. leads if not specified.<br>**----- End of picture text -----**<br>
- Color coded for easy amp rating identification
## **Typical Applications**
- Telecommunications DC power circuit protection
## **Catalog Numbers**
|**Catalog Numbers**|**Catalog Numbers**|||
|---|---|---|---|
|**Catalog**<br>**Numbers**<br>GMT-18⁄100A<br>GMT-1⁄4A<br>GMT-3⁄8A<br>GMT-1⁄2A<br>GMT-65⁄100A|**Color**<br>**Code**<br>Yellow<br>Violet<br>Green/Gray<br>Red<br>Black|**Catalog**<br>**Numbers**<br>GMT-3-1⁄2A<br>GMT-4A<br>GMT-5A<br>GMT-7-1⁄2A<br>GMT-10A|**Color**<br>**Code**<br>White/Blue<br>White/Brown<br>Green<br>Black/White<br>Red/White|
|GMT-3⁄4A|Brown|GMT-12A|Yellow/Green|
|GMT-1A|Gray|GMT-15A|Red/Blue|
|GMT-1-1⁄3A<br>GMT-1-1⁄2A<br>GMT-2A<br>GMT-3A|White<br>White/Yellow<br>Orange<br>Blue|GMT-Dummy<br>GMT-X<br>GMT-Y|GrayBody<br>Clear Cover<br>Clear Cover|
Some GMT sizes may be sold in bulk pack only.
## **Accessories**
- Spare fuse holder: Catalog Number TPSFH-T
## **GMT-A**
## **Specifications**
**Description:** Fast-acting fuse designed specifically for use in the Telepower series 15800 fused disconnect switch (page 430).
**Agency Information:** The GMT-A has the same ratings and agency approvals as the standard GMT fuses as shown above.
## **Catalog Numbers**
**Catalog Number Color Code** GMT-A Yellow
**Data Sheet: 5008**
**Data Sheet: 5010**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**437**
**Telecom Protection Products**
## **Telpower Specialty Fuses**
## **7 Type**
## **Specifications**
**Description:** Fiber tube, threaded ends. Typically used on wall type main distribution frames and central battery substations.
**Dimensions:** See Catalog Numbers table and Dimensions illustration.
## **Ratings:**
Amps: — 7A
**Agency Information:** CE
## **Catalog Numbers**
**Catalog Amp Lucent Comcode Dimension Numbers Rating Ref. No. A Length (in)** 7A-7 7 100863737 4.562 7T-7 7 100202753 4.828
**A 4.093** ~~**"** —~~ — ~~——,~~
## **Dimensions - in**
## **24 and WER Type**
## **Specifications**
**Description:** Flat, non-indicating visible link element mounted on 1 inch centers using either No. 6 or No. 10 screws.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 32Vdc ([1] ⁄4, 1, 3[1] ⁄2, 8, 10A)
— 60Vdc ([1] ⁄2,[3] ⁄4, 1[1] ⁄2, 2, 3, 4, 5A)
Amps: —[1] ⁄4-10A
**Agency Information:** CE, UL Recognized File E56412.
## **Catalog Numbers**
|**Catalog**|**Amp**|**DC**|**Color**|**Lucent Comcode**|**A Length**|
|---|---|---|---|---|---|
|**Numbers**|**Rating**|**Volts**|**Code**|**Ref. No.**|**Inches**|
|WER-1⁄4|1⁄4|32|—|—|—|
|24E-1⁄2*|1⁄2|60|Red|100202894|0.20|
|24D-3⁄4*|3⁄4|60|Black|100202886|0.15|
|WER-1|1|32|—|—|—|
|24G-1-1⁄3*|11⁄3|60|White|100202910|0.20|
|24C-2*<br>24B-3*<br>WER-3-1⁄2|2<br>3<br>31⁄2|60<br>60<br>32|Orange<br>Blue<br>—|100202878<br>100202852<br>—|0.20<br>0.15<br>—|
|24B-4*|4|60|Yellow|100202860|0.15|
|24F-5*|5|60|Green|100202902|0.15|
|WER-8|8|32|—|—|—|
|WER-10|10|32|—|—|—|
*Designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, Dec. 1988.
## **Dimensions - in**
**1.406" 0.938"** ~~in~~ **A** ~~l i~~ = **A 0.375"** ~~Waser~~
## **11 Type**
## **Specifications**
**Description:** Fiber tube, threaded ends, identical to 7 Type except for vent slots in fiber tube.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Amps: — 7A
**Agency Information:** CE
## **Catalog Number**
**Catalog Amp Lucent Comcode Number Rating Ref. No.** 11C-7 7 100863745
## **Dimensions - in**
**4.625" 4.062"**
## **74 Type**
## **Specifications**
**Description:** Fast-acting 0.281˝ x 1.25˝ cylindrical fuse designed to comply with Lucent specification KS23753. High current companion to 70 Type Fuse.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 60Vdc
Amps: — 1[1] ⁄4-20A
**Agency Information:** CE, UL Recognized File E19180.
## **Catalog Numbers**
|**Catalog**|**Amp**|**Lucent Comcode**|**Code/**|
|---|---|---|---|
|**Numbers**|**Rating**|**Ref. No.**|**List No.**|
|74A-1-1⁄4|11⁄4|102630290|KS23753-L1|
|74G-2|2|103064952|KS23753-L7|
|74B-3|3|102630308|KS23753-L2|
|74H-4|4|103264669|KS23753-L8|
|74C-5|5|102630316|KS23753-L3|
|74J-7-1⁄2|71⁄2|103228425|KS23753-L9|
|74D-10|10|102630324|KS23753-L4|
|74E-15|15|102630332|KS23753-L5|
|74F-20|20|102630340|KS23753-L6|
**Dimensions - in (mm)**
~~(TT~~ **1.25"** (31.75mm) **0.281"** (7.14mm)
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**438**
**Telecom Protection Products** ee
## **Telpower Specialty Fuses**
## **75 Type**
## **Specifications**
**Description:** Cylindrical with leads, designed to provide protection against currents resulting from the application of foreign voltages. Application for data sets and telephones. **Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 135Vac/220Vdc (440Vdc@0.007A) Amps: — 0.007-0.230A
**Agency Information:** CE
## **Catalog Numbers**
**Catalog Amp Lucent Comcode Code/ Numbers Rating Ref. No. List No.** 75C 0.007 103260816 KS23825-L3 75F 0.063 104172861 KS23825-L6 75B 0.115 102732112 KS23825-L2 75D 0.129 104013180 KS23825-L4 75A 0.200 102660008 KS23825-L1 ~~Oe~~
**==> picture [244 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.325" 0.620"<br>(8.26mm) e (15.75mm) n<br>A (4.83mm) 0.190"<br>_ (20.32mm) 0.800" J<br>80 Type ee<br>Specifications<br>Description: A fuse designed for high reliability applications<br>where high ambient temperatures, low circuit voltages, low<br>power dissipation and low contact resistance are prime<br>considerations. The 80 Type is a visual indicating fuse with<br>remote electrical alarm capability. UL Recognized, Guide<br>JDYX2, File E19180.<br>— — A<br>**----- End of picture text -----**<br>
## **80 Type**
## **76 Type**
## **Specifications**
**Description:** Cylindrical with leads, designed to provide protection against currents resulting from the application of foreign voltages. Application for data sets and telephones.
**Dimensions:** See Dimensions illustration.
## **Ratings:**
Volts: — 135Vac/440Vdc Amps: — 0.012-0.412A
**Agency Information:** CE
## **Catalog Numbers**
|**Catalog**|**Amp**|**Lucent Comcode **|**Code/**|
|---|---|---|---|
|**Numbers**|**Rating**|**Ref. No.**|**List No.**|
|76D|0.012|103798245|KS23825-L10|
|76B|0.191|102965688|KS23825-L8|
|76A<br>76C|0.231<br>0.412|102810181<br>103656625|KS23825-L7<br>KS23825-L9|
**0.445" 0.830** ~~**"**~~ (11.30mm) ~~—~~ (21.08mm) **0.320"** (8.13mm) ~~irae~~ **1.125"** (28.58mm) ~~kK— —~~
**Dimensions - in (mm)**
**Dimensions:** See Dimensions illustrations.
## **Ratings:**
Volts: — 160Vdc
Amps: —[1] ⁄2-5A
**Agency Information:** CE, UL Recognized File E19180.
## **Catalog Numbers**
|**Catalog**|**Amp**|**Color**|**Lucent Comcode **|**Code/**|
|---|---|---|---|---|
|**Numbers**|**Rating**|**Code**|**Ref. No.**|**List No.**|
|80G-1⁄2|1⁄2|Red|103839916|KS23824-L6|
|80M-1-1⁄3|11⁄3|White|408078657|KS23824-L8|
|80B-2|2|Orange|103752150|KS23824-L2|
|80C-3|3|Blue|103752168|KS23824-L3|
|80D-5|5|Green|103800637|KS23824-L4|
**Dimensions - in (mm) 2.685"** ~~a~~ (68.20mm) **0.280"** (7.11mm)
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**439**
Surge Protection : Made Simple™ ' UL 508A Applications
Comprehensive UL 1449 3[rd] Edition recognized surge protection solutions for North American applications.
**440**
Scan this tag to get product information about the New Bussmann Surge Protection products for UL, PV, IEC, Wind Power and Telecom applications.
## **Overvoltage Protective Devices**
## **Surge Protective Devices**
## **UL Type 1 NEMA 4X SPDs**
## **RED indicates NEW information**
SurgePOD HEAVY DUTY (Black Label) ...................442-445 SurgePOD PRO (Grey Label) ...................................446-448
## **UL DIN-Rail**
|**High SCCR SPDs**|**High SCCR SPDs**||
|---|---|---|
|1-Pole|Type 2|BSPM_S2G ...............................449-450|
|2-Pole|Type 2|BSPM_S3G ...............................451-452|
|3-Pole|Type 2|BSPM_WYG/DLG......................453-454|
|4-Pole|Type 2|BSPM_WYNG/HLG...................455-456|
|**Low Voltage AC/DC Power**||**Low Voltage AC/DC Power**|
|1-Pole|Type 2|BSPM_LV...................................457-458|
|**Low-Voltage AC/DC Control**||**Low-Voltage AC/DC Control**|
|2-Pole|Type 3|BSPH2A_LV...............................459-460|
## **IEC DIN-Rail**
|**Class I**|||
|---|---|---|
|2-Pole|Class I|BSPS_TN/TT .............................461-462|
|3-Pole|Class I|BSPS_TNC................................463-464|
|4-Pole|Class I|BSPS_TNS/TT...........................465-466|
|**Class II**|||
|1-Pole|Class II|BSPM_TN / BSPG_NPE............467-468|
|2-Pole|Class II|BSPM_TN / BSPH_TT...............469-470|
|3-Pole|Class II|BSPM_TNC ...............................471-472|
|4-Pole|Class II|BSPM_TNS / BSPH_TT ............473-474|
## **Solar Power Photovoltaic (PV) DIN-Rail**
|**Lightning Arrester**|
|---|
|1-Pole<br>PV Advance Lightning Arrester /|
|BSPS_PV ..................................................475-476|
|**Overvoltage Surge Protective Devices**|
|2-Module<br>PV HEAVY DUTY SPD /<br>BSPH2_PV ................................477-478<br>3-Module<br>PV HEAVY DUTY SPD /<br>BSPH_YPV ................................479-480<br>3-Module<br>PV PRO SPD / BSPP_YPV........481-482|
## **Wind Power IEC DIN-Rail**
## **Class I**
|**Class I**|||
|---|---|---|
|1-pole|Class I|BSPS_WE..................................483-484|
|**Class II**|||
|1-Pole|Class II|BSPM_WE / BSPS_WE.............485-486|
|2-Pole|Class II|BSPM_WE / BSPH_WE ............487-488|
|3-Pole|Class II|BSPM_WE.................................489-490|
|4-Pole|Class II|BSPM_WE / BSPH_WE ............491-492|
## **UL 4978 Data Signal SPDs**
DIN-Rail BNC/Coaxial Cable BSPD5BNCD_ .......493-494 In-Line BNC/Coaxial Cable BSPD5BNCSI ........495-496 DIN-Rail RJ45/Ethernet Cable BSPD48RJ45 .........497-498 DIN-Rail Universal 4 Wire BSPD_DIN_............499-501
## **Surge Protective Overvoltage Device Modules**
**SurgePod™ Series, 150 to 550Vac MCOV ...........502-503 DIN-Rail TVS Series with Holder..................................504**
Scan this tag to get access to the Surge Protective Devices Cross Reference Search.
**441**
**Overvoltage Devices**
## **SURGE PROTECTION MADE SIMPLE™ FOR COMMERCIAL & INDUSTRIAL APPLICATIONS** SURGEPOD™ HEAVY DUTY SPD FOR UL 1449 ~~3~~[rd] Edition Listed Loadside and Lineside Protection
## **Description**
The Bussmann SurgePOD™ HEAVY DUTY is a Type 1 UL Listed 1449 3rd Edition surge protective device suitable for installation on both the loadside or lineside of the service 7 entrance overcurrent protective device.
Available in voltage and system specific versions to match electrical system and equipment requirements. The SurgePOD HEAVY DUTY delivers optimum surge protection using advanced patent pending SurgePOD™ module featuring thermal disconnect technology that eliminates the need for additional overcurrent protection.
Parallel connection to the electrical system permits the SurgePOD HEAVY DUTY SPD to be installed on **any** ampacity panel.
- Type 1 UL 1449 3rd Edition Listed SPDs are easily selected and installed on the loadside or lineside of the service entrance overcurrent protective device
- Patented Bussmann SurgePOD module technology eliminates the need for additional fusing
- Voltage specific models precisely match and protect electrical systems and equipment up to 600Vac
- Compact UV resistant NEMA 4X for indoor or outdoor applications
- _easy_ ID™ LED status indicator provides surge protection status at a glance
**==> picture [32 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
SPD Type 2<br>**----- End of picture text -----**<br>
**==> picture [65 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
easy ID™ LED<br>Status Indicator<br>**----- End of picture text -----**<br>
**SPH50SP1120SN SPH50SP2480PN SPH50SP3208WYG SPH50SP1240SN SPH50SP3240PNG SPH50SP3480WYG SPH50SP1347SN SPH50SP3480PNG SPH50SP3600WYG SPH50SP2120SNG SPH50SP3240DLG SPH50SP4208WYNG SPH50SP2240SNG SPH50SP3480DLG SPH50SP4480WYNG SPH50SP2347SNG SPH50SP4240HLG SPH50SP4600WYNG SPH50SP2240PN SPH50SP4480HLG**
## **NEMA 4X Rated Heavy Duty Type 1 UL Listed SPD**
## **Dimensions - in**
## **Type 1 SPD Part Number System**
**SPH 50S PX XXX XXX**
**==> picture [150 x 179] intentionally omitted <==**
**----- Start of picture text -----**<br>
[|<br>|<br>fj<br>i=)<br>1-1/16” Dia.<br>1-11/16”<br>3-3/8”<br>1-11/16”<br>2-1/16” 2-1/16”<br>4-1/8”<br>3-3/16”<br>4-1/16”<br>7/8”<br>**----- End of picture text -----**<br>
## **SPH = Product Series**
Surge Protection Heavy Duty
## **Surge Rating**
50S = 50kA max discharge current
## **No of Wires/Poles**
P1 = 1 P2 = 2 P3 = 3 P4 = 4
## **Rated System Voltage**
120, 208, 240, 347, 480, 600Vac
## **System**
SN = Single-Phase 2 Wire, 2 Connection Points SNG = Single-Phase 2 Wire + G, 3 Connection Points PN = Split-Phase 3 Wire , 3 Connection Points PNG = Split-Phase 3 Wire + G, 4 Connection Points DLG = Three-Phase Delta 3 Wire + G, 4 Connection Points HLG = Three-Phase Highleg Delta 4 Wire + G, 5 Connection Points WYG = Three-Phase Wye 3 Wire, 4 Connection Points WYNG = Three-Phase Wye 3 Wire + G, 5 Connection Points
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**442**
**Overvoltage Devices**
## **SurgePOD™ HEAVY DUTY Technical Information**
||||**Nominal**|**Max. Continuous**|||
|---|---|---|---|---|---|---|
||||**System**|**Operating AC**||**Connection**|
|**Catalog Number**|||**Voltage**|**Voltage (MCOV) (VC)**|**System Type**|**Points**|
|SPH50SP1120SN|||120V|150V|Single-Phase 2 Wire|2|
|SPH50SP1240SN|||240V|320V|Single-Phase 2 Wire|2|
|SPH50SP1347SN|||347V|420V|Single-Phase 2 Wire|2|
|SPH50SP2120SNG|||120V|150V|Single-Phase 2 Wire + G|3|
|SPH50SP2240SNG|||240V|320V|Single-Phase 2 Wire + G|3|
|SPH50SP2347SNG|||347V|420V|Single-Phase 2 Wire + G|3|
|SPH50SP2240PN|||120/240V|150V|Split-Phase 3 Wire|3|
|SPH50SP2480PN|||240/480V|320V|Split-Phase 3 Wire|3|
|SPH50SP3240PNG|||120/240V|150V|Split-Phase 3 Wire + G|4|
|SPH50SP3480PNG|||240/480V|320V|Split-Phase 3 Wire + G|4|
|SPH50SP3240DLG|||240V|320V|Three-Phase Delta 3 Wire + G|4|
|SPH50SP3480DLG|||480V|550V|Three-Phase Delta 3 Wire + G|4|
|SPH50SP4240HLG|||120/240V|150/320V|Three-Phase HighlegDelta 4 Wire + G|5|
|SPH50SP4480HLG|||240/480V|320/550V|Three-Phase HighlegDelta 4 Wire + G|5|
|SPH50SP3208WYG|||208V|150V|Three-Phase Wye 3 Wire + G|4|
|SPH50SP3480WYG|||480V|320V|Three-Phase Wye 3 Wire + G|4|
|SPH50SP3600WYG|†||600V|420V|Three-Phase Wye 3 Wire + G|4|
|SPH50SP4208WYNG|||208Y/120V|150V|Three-Phase Wye 4 Wire + G|5|
|SPH50SP4480WYNG|||480Y/277V|320V|Three-Phase Wye 4 Wire + G|5|
|SPH50SP4600WYNG||†|600Y/347V|420V|Three-Phase Wye 4 Wire + G|5|
† 600V Wye versions are not CSA Certified.
## **SurgePOD™ HEAVY DUTY Technical Information**
|**Specifications(for all SurgePOD HD units)**||**Values**|
|---|---|---|
|Short Circuit Current Rating (SCCR)||200kA|
|Nominal Discharge Current(8x20μs)In||20kA|
|Max. Discharge Current(8x20μs)Imax||50kA|
|Response Time tA||<25ns|
|Frequency||50/60Hz|
|OperatingState/Fault Indication|Bi-Color LED|- Green(good)/ Red(replace)|
|Conductor Length / Guage|18 inches,10|AWG Stranded Tinned Copper|
|Mounting|Chase Nipple / Bracket*||
|Enclosure / FlammabilityRatings|NEMA 4X - UL 94-5VA||
|Degree of Protection(Installed State)||IP20(finger-safe)|
|SPD Install Location||Indoor/Outdoor|
|Circuit Location|Lineside or Loadside of service entrance overcurrentprotective device||
|Standard|UL 1449 3|rd<br>Edition Type 1 Listed SPD|
|AgencyInformation|cULus,|CSA**,RoHS Compliant|
|Product Warranty||5 Years***|
|OperatingTemperature||-40˚C to +85˚C|
|Maximum Operating Altitude||16,000FT|
* Customer-supplied bracket.
** 600V Wye versions not CSA Certified.
*** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**443**
**Overvoltage Devices**
## **Voltage Protection Ratings (VPRs)**
|**Catalog Number**|**Rated System**<br>**Voltage (Vo)**|**MCOV**<br>**(VC)**|**Voltage Protection Ratings (VPRs)**|**Voltage Protection Ratings (VPRs)**|**Voltage Protection Ratings (VPRs)**|**Voltage Protection Ratings (VPRs)**|
|---|---|---|---|---|---|---|
||||**L-N**|**L-L**|**L-G**|**N-G**|
|SPH50SP1120SN<br>~~eG~~<br>~~es~~|120V<br>~~eG~~|150V<br>~~eG~~|700<br>~~OO~~|—<br>~~OO~~|—<br>~~OO~~|—|
|SPH50SP1240SN<br>~~es~~<br>~~es~~|240V<br>~~Gn~~|320V<br>~~Gn~~|1200<br>~~OO~~|—<br>~~OO~~|—<br>~~OO~~|—<br>~~OO~~|
|SPH50SP1347SN<br>~~es~~<br>~~es~~<br>~~es~~|347V<br>~~Gn~~|420V<br>~~Gn~~|1500<br>~~OO~~|—<br>~~OO~~|—<br>~~OO~~|—<br>~~OO~~|
|SPH50SP2120SNG<br>~~es~~<br>~~es~~<br>~~es~~|120V<br>~~Gn~~<br>~~GO~~|150V<br>~~Gn ~~<br>~~GO~~|700<br> ~~OO~~<br>~~GO~~|—<br>~~OO~~<br>~~GO~~|1200<br>~~OO~~<br>~~GO~~|700<br>~~OO~~<br>~~GO~~|
|SPH50SP2240SNG<br>~~es~~<br>~~es~~<br>~~es~~|240V<br>~~GO~~<br>~~eG~~|320V<br>~~GO~~<br>~~eG~~|1200<br>~~GO~~<br>~~OO~~|—<br>~~GO~~<br>~~OO~~|2500<br>~~GO~~<br>~~OO~~|1200<br>~~GO~~|
|SPH50SP2347SNG<br>~~es~~<br>~~es~~|347V<br>~~GO~~<br>~~eG~~|420V<br>~~GO~~<br>~~eG~~|1500<br>~~GO~~<br>~~OO~~|—<br>~~GO~~<br>~~OO~~|2500<br>~~GO~~<br>~~OO~~|1500<br>~~GO~~|
|SPH50SP2240PN<br>~~es~~<br>~~GO~~|120V/240V<br>~~eG~~<br>~~GO~~|150V<br>~~eG~~<br>~~GO~~|700<br>~~OO~~<br>~~GO~~|1200<br>~~OO~~<br>~~GO~~|—<br>~~OO~~<br>~~GO~~|—<br>~~GO~~|
|SPH50SP2480PN<br>~~GG~~<br>~~es~~|240V/480V<br>~~GG~~<br>~~es~~|320V<br>~~GG~~|1200<br>~~GG~~|2500<br>~~GG~~|—<br>~~GG~~|—<br>~~GG~~|
|SPH50SP3240PNG<br>~~es~~<br>~~es~~|120V/240V<br>~~es~~<br>~~Ge~~|150V<br>~~Ge~~|700|1200|1200|700|
|SPH50SP3480PNG<br>~~es~~<br>~~es~~|240V/480V<br>~~es~~<br>~~Ge~~|320V<br>~~Ge~~|1200|2500|2500|1200|
|SPH50SP3240DLG<br>~~es~~<br>~~ss~~<br>~~es~~|240V<br>~~Ge~~<br>~~ss~~<br>~~es~~|320V<br>~~Ge~~<br>~~GQ~~<br>~~GO~~|—<br>~~GQ~~<br>~~GO~~|2500<br>~~GQ~~<br>~~GO~~|1200<br>~~GQ~~<br>~~GO~~|—<br>~~GO~~|
|SPH50SP3480DLG<br>~~ss~~<br>~~es~~|480V<br>~~ss~~<br>~~es~~|550V<br>~~GQ~~<br>~~GO~~|—<br>~~GQ~~<br>~~GO~~|3000<br>~~GQ~~<br>~~GO~~|1800<br>~~GQ~~<br>~~GO~~|—<br>~~GO~~|
|SPH50SP4240HLG<br>~~es~~<br>~~eG~~<br>~~es~~|120/240V<br>~~es~~<br>~~eG~~|150V/320V<br>~~GO~~<br>~~eG~~|700/1200<br>~~GO~~<br>~~OO~~|1200/2500<br>~~GO~~<br>~~OO~~|1200/2500<br>~~GO~~<br>~~OO~~|700/1200<br>~~GO~~|
|SPH50SP4480HLG<br>~~es~~<br>~~es~~|240/480V<br>~~Gn~~|320V/550V<br>~~Gn~~|1200/1800<br>~~OO~~|2500/3000<br>~~OO~~|2500/3000<br>~~OO~~|1200/1800<br>~~OO~~|
|SPH50SP3208WYG<br>~~es~~<br>~~es~~<br>~~es~~|208V<br>~~Gn~~|150V<br>~~Gn~~|—<br>~~OO~~|1200<br>~~OO~~|700<br>~~OO~~|—<br>~~OO~~|
|SPH50SP3480WYG<br>~~es~~<br>~~es~~<br>~~es~~|480V<br>~~Gn~~<br>~~GO~~|320V<br>~~Gn ~~<br>~~GO~~|—<br> ~~OO~~<br>~~GO~~|2500<br>~~OO~~<br>~~GO~~|1200<br>~~OO~~<br>~~GO~~|—<br>~~OO~~<br>~~GO~~|
|SPH50SP3600WYG<br>†<br>~~es~~<br>~~es~~<br>~~es~~|600V<br>~~GO~~<br>~~eG~~|420V<br>~~GO~~<br>~~eG~~|—<br>~~GO~~<br>~~OO~~|2500<br>~~GO~~<br>~~OO~~|1500<br>~~GO~~<br>~~OO~~|—<br>~~GO~~|
|SPH50SP4208WYNG<br>~~es~~<br>~~es~~|208Y/120V<br>~~GO~~<br>~~eG~~|150V<br>~~GO~~<br>~~eG~~|700<br>~~GO~~<br>~~OO~~|1200<br>~~GO~~<br>~~OO~~|1200<br>~~GO~~<br>~~OO~~|700<br>~~GO~~|
|SPH50SP4480WYNG<br>~~es~~<br>~~GO~~|480Y/277V<br>~~eG~~<br>~~GO~~|320V<br>~~eG~~<br>~~GO~~<br>~~es~~|1200<br>~~OO~~<br>~~GO~~<br>~~Gs~~|2500<br>~~OO~~<br>~~GO~~<br>~~Gs~~|2500<br>~~OO~~<br>~~GO~~|1200<br>~~GO~~|
|SPH50SP4600WYNG<br>†<br>~~ss~~|600Y/347V<br>~~ss~~|420V<br>~~ss~~<br>~~es~~|1500<br>~~ss~~<br>~~Gs~~|2500<br>~~ss~~<br>~~Gs~~|2500<br>~~ss~~|1500<br>~~ss~~|
† 600V Wye versions are not CSA Certified.
## _**easy**_ **ID™ LED Status Indicator**
The _easy_ ID™ LED status indicator will illuminate when the unit is properly installed and the system or equipment being protected is energized. The following LED color/status indicates:
## **GREEN LED = Good**
The circuit is energized and _protected_ .
## **RED LED = Replace**
The circuit is _energized_ **and** _unprotected_ . The unit **needs** replacing.
## **Mounting**
SurgePOD HEAVY DUTY is a panel mount device. It may also be mounted using a customer supplied bracket or directly onto a female threaded conduit fitting.
**==> picture [113 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
KF<br>For NEMA 4X installation,<br>install appropriate customer<br>supplied gasket between<br>SurgePOD™ HEAVY DUTY<br>SPD and enclosure wall.<br>Tighten locknut to<br>20.3 Lb-In (2.3N•m)<br>**----- End of picture text -----**<br>
## **LED is Out / Unlit:**
- The circuit is most likely deenergized
- The unit’s leads are disconnected
- The unit is damaged
Authorized personnel should follow all prescribed lockout/tagout and safety procedures in troubleshooting the cause for the above conditions. Opening SurgePOD HEAVY DUTY enclosure will void UL listing and warranty.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**444**
**Overvoltage Devices**
## **Wiring Connections**
## **Single-Phase**
**==> picture [226 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
Black<br>White<br>120, 240, 347V (L-N) SPH50SP1120SN,<br>2 Wire SPH50SP1240SN,<br>Must be installed within 10 feet (3m) of a bonded SPH50SP1347SN<br>neutral-ground connection per IEEE C62.41-1991<br>L (Black)<br>N (White)<br>**----- End of picture text -----**<br>
## **Two-Pole with Neutral**
**==> picture [237 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
Black<br>Black<br>White<br>SPH50SP2240PN,<br>120V (L-N) / 240V (L1-L2),<br>240V (L-N) / 480V (L1-L2) SPH50SP2480PN<br>Single Phase (Split) Center Tap<br>L1 (Black)<br>N (White)<br>L2 (Black)<br>**----- End of picture text -----**<br>
For installations at or less than 10 feet (3m) from the transformer.
## **Wye + Ground**
**==> picture [233 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 (Black)<br>L2 (Black)<br>Black<br>Black<br>Black<br>Green<br>L3 (Black)<br>SPH50SP3208WYG,<br>GND (Green)<br>SPH50SP3480WYG,<br>208, 480, 600V (L-L) SPH50SP3600WYG<br>3 Wire Wye + Ground<br>**----- End of picture text -----**<br>
## **Wye with Neutral + Ground**
**==> picture [233 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 (Black)<br>L2 (Black) Black<br>Black<br>Black<br>N (White)<br>White<br>Green<br>L3 (Black) SPH50SP4208WYNG,<br>GND (Green) SPH50SP4480WYNG,<br>120V (L-N) / 208V (L-L), SPH50SP4600WYNG<br>127V (L-N) / 220V (L-L),<br>277V (L-N) / 480V (L-L),<br>347V (L-N) / 600V (L-L)<br>4 Wire Wye + Ground<br>**----- End of picture text -----**<br>
## **Delta + Ground**
## **Single-Phase + Ground**
**==> picture [378 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
240, 480V (L-L)<br>3 Wire Delta + Ground<br>L1 (Black)<br>L2 (Black)<br>L3 (Black)<br>GND (Green)<br>Black<br>White<br>Green<br>L (Black)<br>N (White)<br>GND (Green)<br>120, 240, 347V (L-N) SPH50SP2120SNG,<br>2 Wire + Ground SPH50SP2240SNG,<br>For installation when located greater than 10 feet (3m) SPH50SP2347SNG<br>of a bonded neutral-ground connection.<br>**----- End of picture text -----**<br>
**==> picture [111 x 88] intentionally omitted <==**
**----- Start of picture text -----**<br>
Black<br>Black<br>Black<br>Green<br>SPH50SP3240DLG,<br>SPH50SP3480DLG<br>**----- End of picture text -----**<br>
## **Two-Pole with Neutral + Ground**
## **Highleg Delta**
**==> picture [380 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
L2 (Orange)<br>Highleg<br>L3 (Black)<br>N (White)<br>L1 (Black)<br>GND (Green)<br>120V (L1 / L3-N) / 240V (L-L),<br>240V (L1 / L3-N) / 480V (L-L)<br>Black<br>Black<br>White<br>Green<br>SPH50SP3240PNG,<br>120V (L-N) / 240V (L1-L2),<br>240V (L-N) / 480V (L1-L2) SPH50SP3480PNG<br>Single Phase (Split) Center Tap + Ground<br>L1 (Black)<br>N (White)<br>L2 (Black)<br>GND (Green)<br>**----- End of picture text -----**<br>
**==> picture [94 x 27] intentionally omitted <==**
**----- Start of picture text -----**<br>
120V (L1 / L3-N) / 240V (L-L),<br>240V (L1 / L3-N) / 480V (L-L)<br>4 Wire Highleg Delta + Ground<br>**----- End of picture text -----**<br>
For installation when located greater than 10 feet (3m) of a bonded neutral-ground connection.
**==> picture [111 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
Black<br>Black<br>White<br>Green<br>Orange<br>SPH50SP4240HLG,<br>SPH50SP4480HLG<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**445**
**Overvoltage Devices**
**SURGE PROTECTION MADE SIMPLE™ FOR LIGHT COMMERCIAL & RESIDENTIAL APPLICATIONS** SURGEPOD™ PRO SPD FOR UL 1449 ~~3~~[rd] Edition Listed Loadside and Lineside Protection
## **Description**
The Bussmann SurgePOD™ PRO is a Type 1 UL Listed 1449 ~~3~~ rd Edition surge protective device suitable for installation on both the loadside or lineside of the service entrance overcurrent protective device.
Available in popular voltage and system specific versions to match common residential and light commercial electrical system and equipment requirements. The SurgePOD PRO delivers superior surge protection using MOV thermal disconnect technology that eliminates the need for additional overcurrent protection.
**==> picture [65 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
easy ID™ LED<br>Status Indicator<br>**----- End of picture text -----**<br>
Parallel connection to the electrical system permits the SurgePOD PRO SPD to be installed on **any** ampacity panel.
- Type 1 UL 1449 3rd Edition Listed SPDs are easily selected and installed on the loadside or lineside of the service entrance overcurrent protective device
- Voltage specific models precisely match and protect electrical systems and equipment better than “one-size-fits-all” SPDs
**SPP40SP1120SN SPP40SP3240DLG SPP40SP3208WYG SPP40SP2240PN SPP40SP3480DLG SPP40SP3480WYG**
- Thermal disconnect technology eliminates the need for additional fusing
- Compact UV resistant NEMA 4X enclosure for indoor or outdoor applications
- _easy_ ID™ LED status indicator provides surge protection status at a glance
## **NEMA 4X Rated Pro Type 1 UL Listed SPD**
## **Dimensions - in**
**==> picture [150 x 180] intentionally omitted <==**
**----- Start of picture text -----**<br>
Be<br>—<br>=<br>1-1/16” Dia.<br>1-11/16”<br>3-3/8”<br>1-11/16”<br>2-1/16” 2-1/16”<br>4-1/8”<br>3-3/16”<br>4-1/16”<br>7/8”<br>**----- End of picture text -----**<br>
## **Type 1 SPD Part Number System**
**SPP 40S PX XXX XXX**
## **SPP = Product Series**
Surge Protection PRO
## **Surge Rating**
40S = 40kA max discharge current
## **No of Wires/Poles**
P1 = 1 P2 = 2 P3 = 3 P4 = 4
## **Rated System Voltage**
120, 208, 240, 480Vac
## **System**
SN = Single-Phase 2 Wire, 2 Connection Points PN = Split-Phase, 3 Wire, 3 Connection Points DLG = Three-Phase Delta 3 Wire + G, 4 Connection Points WYG = Three-Phase Wye 3 Wire, 4 Connection Points
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**446**
**Overvoltage Devices**
## **SurgePOD™ PRO Technical Information**
|**Catalog Number**|**Nominal**<br>**System**<br>**Voltage**|**Max. Continuous**<br>**Operating AC**<br>**Voltage (MCOV) (VC)**|**System Type**|**Connection**<br>**Points**|
|---|---|---|---|---|
|SPP40SP1120SN|120V|150V|Single-Phase 2 Wire|2|
|SPP40SP2240PN|120/240V|150V|Split Phase 3 Wire|3|
|SPP40SP3240DLG|240V|320V|Three-Phase Delta 3 Wire + G|4|
|SPP40SP3480DLG|480V|550V|Three-Phase Delta 3 Wire + G|4|
|SPP40SP3208WYG|208V|150V|Three-Phase Wye 3 Wire + G|4|
|SPP40SP3480WYG|480V|320V|Three-Phase Wye 3 Wire + G|4|
**==> picture [524 x 231] intentionally omitted <==**
**----- Start of picture text -----**<br>
Specifications (for all SurgePOD PRO units) Values<br>Short Circuit Current Rating (SCCR) 200kA<br>Nominal Discharge Current (8x20μs) In 10kA<br>Max. Discharge Current (8x20μs) Imax 40kA<br>Response Time (ns) tA <25ns<br>Frequency 50/60Hz<br>Operating State/Fault Indication Bi-Color LED - Green (good) / Red (replace)<br>Conductor Length / Guage 18 inches, 10 AWG Stranded Tinned Copper<br>Mounting Chase Nipple / Bracket*<br>Enclosure / Flammability Ratings NEMA 4X - UL 94-5VA<br>Degree of Protection (Installed State) IP20 (finger-safe)<br>SPD Install Location Indoor/Outdoor<br>Circuit Location Lineside or Loadside of service entrance overcurrent protective device<br>Standard UL 1449 3 rd Edition Type 1 Listed SPD<br>Agency Information cULus, RoHS Compliant<br>Product Warranty 2 Years**<br>Operating Temperature -40˚C to +65˚C<br>Maximum Operating Altitude 12000FT<br>**----- End of picture text -----**<br>
* Customer-supplied bracket.
** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.
## **Voltage Protection Ratings (VPRs)**
**==> picture [453 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal System MCOV Voltage Protection Ratings (VPRs)<br>Catalog Number Voltage (VC) L-N L-L L-G<br>SPP40SP1120SN 120V 150V 700 — —<br>SPP40SP2240PN 120V/240V 150V 700 1200 —<br>SPP40SP3240DLG 240V 320V — 2500 1200<br>SPP40SP3480DLG 480V 550V — 3000 1800<br>SPP40SP3208WYG 208V 150V — 1200 700<br>SPP40SP3480WYG 480V 320V — 2500 1200<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**447**
**Overvoltage Devices**
## _**easy**_ **ID™ LED Status Indicator**
The _easy_ ID™ LED status indicator will illuminate when the unit is properly installed and the system or equipment being protected is energized. The following LED color/status indicates:
## **GREEN LED = Good**
The circuit is energized and _protected_ .
## **RED LED = Replace**
The circuit is _energized_ **and** _unprotected_ .
## **Wiring Connections**
## **Single-Phase**
**==> picture [43 x 80] intentionally omitted <==**
**----- Start of picture text -----**<br>
L (Black)<br>N (White)<br>120V (L-N)<br>2 Wire<br>**----- End of picture text -----**<br>
Must be installed within 10 feet (3m) of a bonded neutral-ground connection per IEEE C62.41-1991
## **Two-Pole with Neutral**
**==> picture [90 x 44] intentionally omitted <==**
**----- Start of picture text -----**<br>
Black<br>White<br>SPP40SP1120SN<br>**----- End of picture text -----**<br>
The unit **needs** replacing.
## **LED is Out / Unlit:**
- The circuit is most likely deenergized
- The unit’s leads are disconnected
- The unit is damaged
Authorized personnel should follow all prescribed lockout/tagout and safety procedures in troubleshooting the cause for the above conditions. Opening SurgePOD PRO enclosure will void UL listing and warranty.
## **Mounting**
SurgePOD PRO is a panel mount device. It may also be mounted using a customer supplied bracket or directly onto a female threaded conduit fitting.
**==> picture [108 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
_<br>For NEMA 4X installation,<br>install appropriate customer<br>supplied gasket between<br>SurgePOD™ PRO<br>SPD and enclosure wall.<br>Tighten locknut to<br>20.3 Lb-In (2.3N•m)<br>**----- End of picture text -----**<br>
**==> picture [94 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
120V (L-N) / 240V (L1-L2),<br>Single Phase (Split) Center Tap<br>L1 (Black)<br>N (White)<br>L2 (Black)<br>**----- End of picture text -----**<br>
**==> picture [12 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
Black<br>Black<br>White<br>**----- End of picture text -----**<br>
**==> picture [56 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
SPP40SP2240PN,<br>**----- End of picture text -----**<br>
For installations at or less than 10 feet (3m) from the transformer.
## **Wye + Ground**
**==> picture [208 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 (Black)<br>L2 (Black)<br>Black<br>Black<br>Black<br>e S;<br>Green<br>L3 (Black)<br>SPP40SP3208WYG,<br>GND (Green)<br>SPP40SP3480WYG<br>208, 480V (L-L)<br>3 Wire Wye + Ground<br>**----- End of picture text -----**<br>
## **Delta + Ground**
**==> picture [209 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
Black<br>Black<br>Black<br>Green<br>240, 480V (L-L) SPP40SP3240DLG,<br>3 Wire Delta + Ground SPP40SP3480DLG<br>L1 (Black)<br>L2 (Black)<br>L3 (Black)<br>GND (Green)<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**448**
**Overvoltage Devices** ee:
## **UL DIN-Rail SPD - High SCCR**
## **BSPM_ _ _ _S2G**
## **Dimensions - mm**
**==> picture [198 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>easylD"a<br>**----- End of picture text -----**<br>
Shown with optional remote contact signaling
## **Specifications**
## **Description**
The Bussmann single pole UL modular surge arresters for 120, 240 and 347Vac single-phase systems feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
## **Features**
- Surge arrester according to UL 1449 3[rd] Edition, Type 2 Component Assembly helps meet UL 508A requirements
- Heavy-duty zinc oxide varistors for high discharge capacity
- "Thermo Dynamic Control" SPD monitoring device ensures high reliability against surge events
- Module locking system with module release button makes module replacement easy without tools
- Up to 200kA Short-Circuit Current Rating (SCCR) makes higher _assembly_ SCCR ratings possible
- Optional remote signaling of all protection modules makes status monitoring easy and accurate in any monitoring scheme
## **Circuit Diagram**
**==> picture [190 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
L<br>MOV<br>12<br>11 12<br>14 amy, | 11 Optional Remote<br>14 Signal Contact<br>Thermal<br>Disconnector<br>| |_* fl|<br>Ld<br>Gnd/N<br>**----- End of picture text -----**<br>
## **BSPM1120S2G, BSPM1240S2G, BSPM1347S2G***
Shown with optional remote contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPM1347S2GR
- No upstream overcurrent protection necessary to make installation easier and more economical
- Vibration and shock tested according to EN 60068-2 to withstand harsh environments
## **Optional Remote Signaling Contact**
The remote signaling contact versions have a floating changeover contact for use as a break or make contact for easy adoption in any monitoring application.
**Data Sheet: 2149**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**449**
**Overvoltage Devices**
## **UL DIN-Rail SPD - High SCCR**
|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|
|---|---|---|---|---|
|NominalSystem Voltage||120Vac|240,277or 240 &277Vac|347Vac|
|Max.Continuous OperatingACVoltage (MCOV) [VC]||275Vac|385Vac|600Vac|
|Catalog Numbers:|WithoutRemote Signaling|BSPM1120S2G|BSPM1240S2G|BSPM1347S2G|
||With Remote Signaling|BSPM1120S2GR|BSPM1240S2GR|BSPM1347S2GR|
|ReplacementModule|MOV Technology|BPM275UL|BPM385UL|BPM600UL|
||SPECIFICATIONS||||
|RatedVoltage||120-127Vac|240-277Vac|347Vac|
|VoltageProtection RatingVPR||1kV|1.5kV|2kV|
|SCCR||200kA|200kA|125kA|
|Nominal Discharge CurrentIn(kA)||20kA|||
|Max. Discharge CurrentImax(kA)||40kA|||
|ResponseTime tA||_<25ns|||
|Frequency||50/60Hz|||
|Numberof Poles||1|||
|Numberof Wires/Connection Points||2 Wires /2Connection Points|||
|Operating State/FaultIndication||Green(good) /Red (replace)|||
|Cross-Sectional Area (min.)||14AWG-Cu Stranded, Solid or Fine|||
|Cross-Sectional Area (max.)||2AWG-Cu Solid orStranded /4AWG-CuFine|||
|Terminal Torque||45lb-in|||
|For Mounting On||35mm DIN RailpertoEN60715|||
|EnclosureMaterial||Thermoplastic, UL94V0|||
|Degree of Protection||IP20 (finger-safe)|||
|LocationCategory||Indoor|||
|Capacity||1 Mods,DIN 43880|||
|Application||UL Type2ComponentAssembly|||
|Standard||UL 1449, ~~3~~rd<br>Edition|||
|AgencyInformation||cURus, CSA,RoHS Compliant|||
|ProductWarranty||FiveYears*|||
||REMOTE CONTACT SIGNALING||||
|Remote Contact SignalingType||ChangeoverContact|||
|AC Switching Capacity (Volts/Amps)||250V/0.5A|||
|DC Switching Capacity (Volts/Amps)||250V/0.1A;125V/0.2A;75V/0.5A|||
|Conductor Ratings and Cross-Sectional Areafor Remote Contact Signal Terminals||60/75°CMax. 1.5mm2/14AWG Solid/Flexible|||
|Ordering Information||Order from Catalog Numbers Above|||
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [384 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>L2<br>L<br>N<br>N L3<br>120, 240, 347Vac 2 Wire Systems 120, 277, 347Vac 2 Wire Wye Systems<br>**----- End of picture text -----**<br>
Part Numbers for all systems BSPM1120S2G, BSPM1240S2G, BSPM1347S2G
Single Pole BSP UL Series Installation Instructions - Document 3A1636RevA
**Data Sheet: 2149**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**450**
**Overvoltage Devices**
## **UL DIN-Rail SPD - High SCCR**
## **BSPM_ _ _ _S3G**
## **Dimensions - mm**
**==> picture [198 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
mw Remote Signal<br>Visual Status Indication Contact Available<br>**----- End of picture text -----**<br>
Shown with optional remote contact signaling
## **Description**
The Bussmann 2-pole UL modular surge arresters for 120/240, 120/208, 127/254, 240, 240/480, 277/480 and 480Vac (split-phase) systems feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
## **Features**
- Surge arrester according to UL 1449 3[rd] Edition, Type 2 Component Assembly helps meet UL 508A requirements
- Heavy-duty zinc oxide varistors for high discharge capacity
- "Thermo Dynamic Control" SPD monitoring device ensures high reliability against surge events
- Module locking system with module release button make module replacement easy without tools
- Up to 200kA Short-Circuit Current Rating (SCCR) make higher _assembly_ SCCR ratings possible
- Optional remote signaling of all protection modules make status monitoring easy and accurate in any monitoring scheme
## **Circuit Diagram**
**==> picture [204 x 132] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L2<br>oe<br>MOV<br>12 | _j ti ti; 8<br>11<br>14 1112 Optional Remote<br>14 Signal Contact<br>Thermal<br>eal Disconnector<br>a Cn ae<br>Gnd/N Gnd/N<br>**----- End of picture text -----**<br>
## **BSPM2240S3G, BSPM2480S3G***
Shown with optional remote contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPM2480S3GR
- No upstream overcurrent protection necessary to make installation easier and more economical
- Vibration and shock tested according to EN 60068-2 to withstand harsh environments
## **Optional Remote Signaling Contact**
The remote signaling contact versions have a floating changeover contact for use as a break or make contact for easy adoption in any monitoring application.
**Data Sheet: 2150**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**451**
**Overvoltage Devices**
## **UL DIN-Rail SPD - High SCCR**
||ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|
|---|---|---|---|
|NominalSystem Voltage||120/240,240Vac|240/480Vac|
|Max.Continuous OperatingVoltageMCOV|[L-G/L-L]|275/550Vac|385/770Vac|
|Catalog Numbers:|WithoutRemote Signaling|BSPM2240S3G|BSPM2480S3G|
||With Remote Signaling|BSPM2240S3GR|BSPM2480S3GR|
|ReplacementModule|MOV Technology|BPM275UL|BPM385UL|
||SPECIFICATIONS|||
|Rated Voltage||120-127Vac<br>240-254Vac<br>240Vac|240-480Vac<br>480Vac|
|VoltageProtection RatingVPR[L-G/L-L]||1kV/1.8kV|1.5kV/2.5kV|
|Nominal Discharge CurrentIn(kA)||20kA||
|Max. Discharge CurrentImax(kA)||40kA||
|ResponseTime tA||_<25ns||
|SCCR||200kA||
|Frequency||50/60Hz||
|Numberof Poles||2||
|Numberof Wires/Connection Points||2 Wires or3Wires / 3 Connection Points||
|Operating State/FaultIndication||Green(good) /Red (replace)||
|Cross-Sectional Area (min.)||14AWG-Cu Stranded, Solid or Fine||
|Cross-Sectional Area (max.)||2AWG-Cu Solid orStranded,4AWG-CuFine||
|Terminal Torque||45lb-in||
|For Mounting On||35mm DIN-Railper EN60715||
|EnclosureMaterial||Thermoplastic, UL94V0||
|Degree of Protection||IP20 (finger-safe)||
|LocationCategory||Indoor||
|Capacity||2 mods,DIN 43880||
|Application||UL Type2ComponentAssembly||
|Standard||UL 1449, ~~3~~rd<br>Edition||
|AgencyInformation||cURus, CSA,RoHS Compliant||
|ProductWarranty||FiveYears*||
||REMOTE CONTACT SIGNALING|||
|Remote Contact SignalingType||ChangeoverContact||
|AC Switching Capacity (Volts/Amps)||250V/0.5A||
|DC Switching Capacity (Volts/Amps)||250V/0.1A;125V/0.2A;75V/0.5A||
|Conductor Ratings and Cross-Sectional Areafor Remote Contact Signal Terminals||60/75°CMax. 1.5mm2/14AWG Solid/Flexible||
|Ordering Information||Order from Catalog Numbers Above||
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [507 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
L L1 L1 L1<br>L2<br>N<br>L2 L2<br>N<br>L<br>L3<br>120/240V, 240/480Vac 120/208V, 277/480Vac 2 Wire Corner Grounded Delta 2 Wire Ungrounded Delta<br>Single Phase (Split) Center Tap 3 Wire Wye System 240, 480Vac<br>BSPM2240S3G, BSPM2480S3G BSPM2240S3G, BSPM2480S3G BSPM2440S3G, BSPM2480S3G<br>**----- End of picture text -----**<br>
**Data Sheet: 2150**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**452**
**Overvoltage Devices**
## **UL DIN-Rail SPD - High SCCR**
## **BSPM_ _ _ _WYG, BSPM_ _ _ _DLG**
## **Dimensions - mm**
**==> picture [198 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>**----- End of picture text -----**<br>
Shown with optional remote contact signaling
## **Description**
The Bussmann 3-pole UL modular surge arresters for 240 and 480 3-phase Delta, and 120/208, 277/480 and 347/600Vac 3-phase Wye systems feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
## **Features**
- Surge arrester according to UL 1449 3[rd] Edition, Type 2 ~~;~~
- Component Assembly helps meet UL 508A requirements
- Heavy-duty zinc oxide varistors for high discharge capacity
## **Circuit Diagrams**
**==> picture [242 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L2 L3<br>PO<br>12 e ee MOV<br>11<br>14 1112 Optional Remote<br>14 Signal Contact<br>lca cele<br>|1 INU| SHA| |' Thermal<br>Disconnector<br>| ee ee<br>Gnd Gnd<br>**----- End of picture text -----**<br>
- "Thermo Dynamic Control" SPD monitoring device ensures high reliability against surge events
- Module locking system with module release button make module replacement easy without tools
- Up to 200kA Short-Circuit Current Rating (SCCR) make higher _assembly_ SCCR ratings possible
- Optional remote signaling of all protection modules make status monitoring easy and accurate in any monitoring scheme
## **BSPM3208WYG, BSPM3480WYG), BSPM3600WYG, BSPM3240DLG, BSPM3480DLG***
Shown with optional remote contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPM3480DLGR
- No upstream overcurrent protection necessary to make installation easier and more economical
- Vibration and shock tested according to EN 60068-2 to withstand harsh environments
## **Optional Remote Signaling Contact**
The remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
**Data Sheet: 2151**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**453**
**Overvoltage Devices**
## **UL DIN-Rail SPD - High SCCR**
|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|
|---|---|---|---|---|---|---|
|NominalSystem Voltage||120/208Vac|240Vac|277/480Vac|480Vac|347/600Vac|
|Max.Continuous OperatingACVoltageMCOV[L-G/L-L]||275/550Vac|275/550Vac|385/770Vac|600/1200Vac|600/1200Vac|
|Catalog Numbers:|WithoutRemote Signaling|BSPM3208WYG|BSPM3240DLG|BSPM3480WYG|BSPM3480DLG|BSPM3600WYG|
||With Remote Signaling|BSPM3208WYGR|BSPM3240DLGR|BSPM3480WYGR|BSPM3480DLGR|BSPM3600WYGR|
|ReplacementModule|MOV Technology|BPM275UL|BPM275UL|BPM385UL|BPM600UL|BPM600UL|
||SPECIFICATIONS||||||
|Rated Voltage||120-127Vac,<br>208-220Vac|240Vac|277/480Vac|480Vac|347/600Vac|
|VoltageProtection RatingVPR [L-G/L-L]||1kV/1.8kV|1kV/1.8kV|1.5kV/2.5kV|2kV/4kV|2kV/4kV|
|SCCR||200kA|200kA|200kA|125kA|125kA|
|Nominal Discharge CurrentIn(kA)||20kA|||||
|Max. Discharge CurrentImax(kA)||40kA|||||
|ResponseTime tA||_<25ns|||||
|Frequency||50/60Hz|||||
|Numberof Poles||3|||||
|Numberof Wires/Connection Points||3Wires /4Connection Points|||||
|Operating State/FaultIndication||Green(good) /Red (replace)|||||
|Cross-Sectional Area (min.)||14AWG-Cu Stranded, Solid or Fine|||||
|Cross-Sectional Area (max.)||2AWG-Cu Solid orStranded,4AWG-CuFine|||||
|Terminal Torque||45lb-in|||||
|For Mounting On||35mm DIN-RailpertoEN60715|||||
|EnclosureMaterial||Thermoplastic, UL94V0|||||
|Degree of Protection||IP20 (finger-safe)|||||
|LocationCategory||Indoor|||||
|Capacity||3Mods,DIN 43880|||||
|Application||UL Type2ComponentAssembly|||||
|Standard||UL 1449, ~~3~~rd<br>Edition|||||
|AgencyInformation||cURus, CSA,RoHS Compliant|||||
|ProductWarranty||FiveYears*|||||
|REMOTE CONTACT SIGNALING|||||||
|Remote Contact SignalingType||ChangeoverContact|||||
|AC Switching Capacity (Volts/Amps)||250V/0.5A|||||
|DC Switching Capacity (Volts/Amps)||250V/0.1A;125V/0.2A;75V/0.5A|||||
|Conductor Ratings and Cross-Sectional Area for<br>Remote Contact Signal Terminals||60/75°C Max. 1.5mm2/14AWG Solid/Flexible|||||
|Ordering Information||Order from Catalog Numbers Above|||||
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [439 x 182] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L1<br>L2 L2<br>L1<br>L2<br>L3<br>L3 L3<br>208, 480, 600Vac 208V, 480V, 600Vac 240, 480Vac<br>Wye 3-Phase, 3 Wire + Ground Delta 3-Phase, 3 Wire + Ground<br>BSPM3208WYG, BSPM3480WYG, BSPM3600WYG BSPM3240DLG, BSPM3480DLG<br>**----- End of picture text -----**<br>
**Data Sheet: 2151**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**454**
**Overvoltage Devices**
## **UL DIN-Rail SPD - High SCCR**
## **BSPM_ _ _ _WYNG, BSPM_ _ _ _HLG**
**Dimensions - mm**
**==> picture [198 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>can’ )<br>**----- End of picture text -----**<br>
Shown with optional remote contact signaling
## **Description**
The Bussmann 4-pole UL modular surge arresters for 120/240, 240/480Vac 3-phase Highleg Delta and 120/208, 127/220, 277/480 and 347/600Vac 3-phase 4 wire Wye systems feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
## **Features**
- **Features** • Surge arrester according to UL 1449 3[rd] Edition, Type 2 .
- Component Assembly helps meet UL 508A requirements
- Heavy-duty zinc oxide varistors for high discharge capacity
- "Thermo Dynamic Control" SPD monitoring device ensures high reliability against surge events
- Module locking system with module release button make module replacement easy without tools
## **Circuit Diagram**
**==> picture [271 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L2 L3 N<br>T T Ta<br>MOV<br>12<br>1411 Lo lealiclicclic al! 1112 5 Optional Remote<br>14 Signal Contact<br>Thermal<br>Disconnector<br>Biavanawa<br>j. ——-oe - -—<br>Gnd Gnd<br>Devices<br>Surge Protection<br>**----- End of picture text -----**<br>
## **BSPM4208WYNG, BSPM4480WYNG, BSPM4600WYNG, BSPM4240HLG, BSPM4480HLG***
Shown with optional remote contact signaling
- Up to 200kA Short-Circuit Current Rating (SCCR) make higher _assembly_ SCCR ratings possible
- Optional remote signaling of all protection modules make status monitoring easy and accurate in any monitoring scheme
- *For remote signaling contact, add “R” suffix to the part number, E.g., BSPM4480HLGR
- No upstream overcurrent protection necessary to make installation easier and more economical
- Vibration and shock tested according to EN 60068-2 to withstand harsh environments
## **Optional Remote Signaling Contact**
The remote signaling contact versions have a floating changeover contact for use as a break or make contact for easy adoption in any monitoring application.
**Data Sheet: 2152**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**455**
**Overvoltage Devices**
## **UL DIN-Rail SPD - High SCCR**
|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|
|---|---|---|---|---|---|---|---|
|Nominal System Voltage|||120/208Vac,<br>127/220Vac|120/240Vac|240/480Vac|277/480Vac|347/600Vac|
|Max. continuous operating AC voltage MCOV[L-N]/[L-G]<br>[N-G]/[L-L]<br>[H-N]/[H-G]<br>[H-L]|||275/550Vac|275/550Vac|385/770Vac|385/660Vac|600/875Vac|
|||[N-G]/[L-L]|275/550Vac|275/550Vac|385/770Vac|275/770Vac|275/1200Vac|
|||[H-N]/[H-G]|- -|275/550Vac|600/985Vac|- -|- -|
|||[H-L]|- -|550Vac|985Vac|- -|- -|
|Catalog Numbers:|WithoutRemote Signaling||BSPM4208WYNG|BSPM4240HLG|BSPM4480HLG|BSPM4480WYNG|BSPM4600WYNG|
||With Remote Signaling||BSPM4208WYNGR|BSPM4240HLGR|BSPM4480HLGR|BSPM4480WYNGR|BSPM4600WYNGR|
|Replacement Modules<br>MOV Technology<br>Four(4)Total Required|Module Positions|L1or L3|BPM275UL|BPM275UL|BPM385UL|BPM385UL|BPM600UL|
|||L2|BPM275UL|BPM275UL|BPM600UL|BPM385UL|BPM600UL|
|||N|BPM275UL|BPM275UL|BPM385UL|BPM275UL|BPM275UL|
|||SPECIFICATIONS||||||
|Rated Voltage|||120/208Vac,<br>127/220Vac|120/240Vac|240/480Vac|277/480Vac|347/600Vac|
|Voltage Protection Rating VPR||[L-N/L-G]|1kV/1.8kV|1kV/1.8kV|1.5kV/2.5kV|1.5kV/2.5kV|2kV/3kV|
|||[N-G/L-L]|1kV/1.8kV|1kV/1.8kV|1.5kV/2.5kV|1kV/2.5kV|1kV/4kV|
|||[H-N/H-G]|- -|1kV/1.8kV|2kV/3kV|- -|- -|
|||[H-L]|- -|1.8kV|3kV|- -|- -|
|SCCR|||200kA|200kA|125kA|200kA|125kA|
|Nominal Discharge CurrentIn(kA)|||20kA|||||
|Max. Discharge CurrentImax(kA)|||40kA|||||
|ResponseTime tA|||_<25ns|||||
|Frequency|||50/60Hz|||||
|Numberof Poles|||4|||||
|Numberof Wires/Connection Points|||4 Wires / 5 Connection Points|||||
|Operating State/FaultIndication|||Green(good) /Red (replace)|||||
|Cross-Sectional Area (min.)|||14AWG-Cu Stranded, Solid or Fine|||||
|Cross-Sectional Area (max.)|||2AWG-Cu Solid orStranded,4AWG-CuFine|||||
|Terminal Torque|||45lb-in|||||
|For Mounting On|||35mm DIN-RailpertoEN60715|||||
|EnclosureMaterial|||Thermoplastic, UL94V0|||||
|Degree of Protection|||IP20 (finger-safe)|||||
|LocationCategory|||Indoor|||||
|Capacity|||4 Mods,DIN 43880|||||
|Application|||UL Type2ComponentAssembly|||||
|Standard|||UL 1449, 3rd<br>edition|||||
|AgencyInformation|||cURus, CSA,RoHS Compliant|||||
|ProductWarranty|||FiveYears*|||||
|||REMOTE CONTACT SIGNALING||||||
|Remote Contact SignalingType|||ChangeoverContact|||||
|AC Switching Capacity (Volts/Amps)|||250V/0.5A|||||
|DC Switching Capacity (Volts/Amps)|||250V/0.1A;125V/0.2A;75V/0.5A|||||
|Conductor Ratings and Cross-Sectional Area for<br>Remote Contact Signal Terminals|||60/75°C Max. 1.5mm2/14AWG Solid/Flexible|||||
|Ordering Information|||Order from Catalog Numbers Above|||||
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [13 x 68] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>L2<br>N<br>L3<br>**----- End of picture text -----**<br>
**==> picture [384 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
L2<br>(Highleg)<br>L1<br>120/208V, 127/220V, 277/480V, 347/600Vac N<br>120/240V, 240/480Vac<br>Wye 3-Phase, 4 Wire + Ground<br>L3 Highleg Delta, 3-Phase, 4 Wire + Ground<br>BSPM4208WYNG, BSPM4480WYNG,<br>BSPM4240HLG, BSPM4480HLG<br>BSPM4600WYNG<br>**----- End of picture text -----**<br>
**Data Sheet: 2152**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**456**
**Overvoltage Devices**
## **UL DIN-Rail SPD - Low Voltage AC/DC Power**
## **BSPM1A_ _ _ _LV**
## **Dimensions - mm**
**==> picture [198 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>casn” (>)<br>**----- End of picture text -----**<br>
## **Description**
The Bussmann UL Type 2 48Vac/60Vdc, 75Vac/100Vdc, 120Vac/200Vdc, 275VAc/350Vdc, 320Vac/420Vdc, 385Vac/500Vdc, 440Vac/585Vdc and 600Vac/dc single pole, modular surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
Shown with optional remote contact signaling
**Module Circuit Diagrams -** Shown with optional remote contact signaling
## **LV Power System Arresters**
The features of these single-pole devices are for use as a single device or in combination with other devices for AC and DC voltage systems.
- Surge arrester according to UL 1449 3[rd] Edition, Type 2 Component Assembly helps meet UL 508A requirements*
**==> picture [60 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Thermal Disconnector<br>MOV<br>**----- End of picture text -----**<br>
- Proven MOV technology for reliable surge protection
- "Thermo Dynamic Control" SPD monitoring device ensures high reliability against surge events
- Module locking system with module release button make module replacement easy without tools
- Optional remote signaling of all protection modules make status monitoring easy and accurate in any monitoring scheme
- No upstream overcurrent protection necessary to make installation easier and more economical
- Vibration and shock tested according to EN 60068-2 to withstand harsh environments
## **Optional Remote Signaling Contact**
The remote signaling contact versions have a floating changeover contact for use as a break or make contact for easy adoption in any monitoring application.
## **BSPM1A48D60LV, BSPM1A75D100LV, BSPM1A150D200LV, BSPM1A275D350LV, BSPM1A320D420LV, BSPM1A385D500LV, BSPM1A440D585LV, BSPM1A600D600LV***
Shown with optional remote contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPM1A150D200LVR
* Except as noted in data sheets.
**Data Sheet: 2056**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**457**
**Overvoltage Devices**
## **UL DIN-Rail SPD - Low Voltage AC/DC Power**
|Ordering Information-48Vac/60Vdc to 275Vac/350Vdc|Ordering Information-48Vac/60Vdc to 275Vac/350Vdc|Ordering Information-48Vac/60Vdc to 275Vac/350Vdc|Ordering Information-48Vac/60Vdc to 275Vac/350Vdc|
|---|---|---|---|
|System Voltage<br>48Vac/60Vdc|75Vac/100Vdc|120Vac/200Vdc|275Vac/350Vdc|
|Catalog Numbers:<br>Without Remote Signaling<br>BSPM1A48D60LV<br>(Base + Modules)<br>With Remote Signaling<br>BSPM1A48D60LVR|BSPM1A75D100LV|BSPM1A150D200LV|BSPM1A275D350LV|
||BSPM1A75D100LVR|BSPM1A150D200LVR|BSPM1A275D350LVR|
|Replacement Modules<br>BPMA48D60LV|BPMA75D100LV|BPMA150D200LV|BPMA275D350LV|
|Specifications||||
|Max. continuous operating AC voltage [V~~C~~]<br>48Vac|75Vac|150Vac|275Vac|
|Max. continuous operating DC voltage [V~~C~~]<br>60Vdc|100Vdc|200Vdc|350Vdc|
|Nominal discharge current (8/20 μs) [I~~n~~]<br>10kA|10kA|15kA|20kA|
|Max. discharge current (8/20 μs) [I~~max~~]<br>25kA|40kA|40kA|40kA|
|Voltage protection level [V~~PR~~]<br>_< 0.3 kV|_< 0.4kV|_< 0.7kV|_< 1.25kV|
|Voltage protection level at 5 kA [V~~PR~~]<br>_< 0.25kV|_< 0.35kV|_< 0.55kV|_< 1kV|
|Temporary overvoltage (TOV)<br>70V / 5 sec.|90V / 5 sec.|175V / 5 sec.|335V / 5 sec|
|Agency Information*<br>- -|UL / cUL,<br>CSA, KEMA|UL / cUL,<br>CSA, KEMA|UL / cUL,<br>CSA, KEMA|
|Ordering Information-320Vac/420Vdc to 600Vac/dc|Ordering Information-320Vac/420Vdc to 600Vac/dc|Ordering Information-320Vac/420Vdc to 600Vac/dc|Ordering Information-320Vac/420Vdc to 600Vac/dc|
|---|---|---|---|
|System Voltage<br>320Vac/420Vdc|385Vac/500Vdc|440Vac/585Vdc|600Vac/600Vdc|
|Catalog Numbers:<br>Without Remote Signaling<br>BSPM1A320D420LV<br>(Base + Modules)<br>With Remote Signaling<br>BSPM1A320D420LVR|BSPM1A385D500LV|BSPM1A440D585LV|BSPM1A600D600LV|
||BSPM1A385D500LVR|BSPM1A440D585LVR|BSPM1A600D600LVR|
|Replacement Modules<br>BPMA320D420LV|BPMA385D500LV|BPMA440D585LV|BPMA600D600LV|
|Specifications||||
|Max. continuous operating AC voltage [V~~C~~]<br>320Vac|385Vac|440Vac|600Vac|
|Max. continuous operating DC voltage [V~~C~~]<br>420Vdc|500Vdc|585Vdc|600Vdc|
|Nominal discharge current (8/20 μs) [I~~n~~]<br>20kA|20kA|20kA|15kA|
|Max. discharge current (8/20 μs) [I~~max~~]<br>40kA|40kA|40kA|30kA|
|Voltage protection level [V~~PR~~]<br>_< 1.5kV|_< 1.75kV|_< 2kV|_< 2.5kV|
|Voltage protection level at 5 kA [V~~PR~~]<br>_< 1.2kV|_< 1.35kV|_< 1.7kV|_< 2kV|
|Temporary overvoltage (TOV)<br>335V / 5 sec.|385V / 5 sec.|580V / 5 sec.|600V / 5 sec.|
|Agency Information*<br>UL / cUL,<br>CSA, KEMA|UL / cUL,<br>CSA, KEMA|UL / cUL,<br>CSA, KEMA|UL / cUL,<br>CSA, KEMA|
|Ordering Information-All Models|Ordering Information-All Models|
|---|---|
|SPD according to EN 61643-11|Type 2|
|SPD according to IEC 61643-1|Class II|
|Response time [t~~A~~]|_< 25 ns|
|TOV characteristics|Withstand|
|Operating temperature range [T~~U~~]|-40°C to +80°C|
|Operating state/fault indication|Green (good) / Red (replace)|
|Number of ports|1|
|Cross-sectional area (min.)|1.5mm2/14AWG solid/flexible|
|Cross-sectional area (max.)|35mm2/1AWG stranded/25mm2/2AWG flexible|
|For mounting on|35mm DIN-Rail per EN 60715|
|Enclosure material|Thermoplastic, UL 94V0|
|Location category|Indoor|
|Degree of protection|IP20|
|Capacity|1 Mod., DIN 43880|
|Product Warranty|Five Years**|
|Remote Contact Signaling||
|Remote Contact Signaling Type|Changeover Contact|
|AC Switching Capacity (Volts/Amps)|250V/0.5A|
|DC Switching Capacity (Volts/Amps)|250V/0.1A; 125V/0.2A; 75V/0.5A|
|Conductor Ratings and Cross-Sectional Area for<br>Remote Contact Signal Terminals|60/75°C Max. 1.5mm2/14AWG Solid/Flexible|
|Ordering Information|Order from Catalog Numbers Above|
* Standards information not applicable to DC ratings.
** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**Data Sheet: 2056**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**458**
**Overvoltage Devices**
## **UL DIN-Rail SPD - Low Voltage AC/DC Control**
## **BSPH2A_ _ _ _LV(R)**
## **Dimensions - mm**
**==> picture [198 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>casyn” (())<br>**----- End of picture text -----**<br>
Shown with optional remote contact signaling
## **Specifications**
## **Description**
The Bussmann UL Type 3 24Vac/dc, 48Vac/dc, 60Vac/dc, 120Vac/dc and 230Vac/dc, two-pole, modular surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
## **Module Circuit Diagrams**
## **LV System Arresters**
The features of these two-pole devices are for use in coordination with other upstream SPDs in UL 508A Applications*.
- Surge arrester according to UL 1449 3[rd] Edition, Type 3 Component Assembly helps meet UL 508A requirements
- Proven MOV and GDT hybrid technology for reliable surge protection
- "Thermo Dynamic Control" SPD monitoring device ensures high reliability against surge events
- Module locking system with module release button make module replacement easy without tools
- Optional remote signaling of all protection modules make status monitoring easy and accurate in any monitoring scheme
- No upstream overcurrent protection necessary to make installation easier and more economical
- Vibration and shock tested according to EN 60068-2 to withstand harsh environments
## **Optional Remote Signaling Contact**
**==> picture [174 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
MOV Gas Discharge Tube (single)<br>**----- End of picture text -----**<br>
## **BPH2A24D24LV BPH2A48D48LV BPH2A60D60LV BPH2A150D150LV BPH2A230D230LV**
Shown with optional remote contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPH2A230D230LVR
The remote signaling contact versions have a floating changeover contact for use as a break or make contact for easy adoption in any monitoring application.
> * UL 1449 ~~3~~[rd] Edition not applicable to DC voltages.
**Data Sheet: 2057**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**459**
**Overvoltage Devices**
## **UL DIN-Rail SPD - Low Voltage AC/DC Power**
|Ordering Information|Ordering Information|Ordering Information|Ordering Information|Ordering Information|Ordering Information|Ordering Information|
|---|---|---|---|---|---|---|
|System Voltage||24Vac/dc|48Vac/dc|60Vac/dc|120Vac/dc|230Vac/dc|
|Max. Continuous operating AC voltage (MCOV) [VC]||30Vac/dc|60Vac/dc|75Vac/dc|150Vac/dc|255Vac/dc|
|Catalog Numbers:<br>(Base + Modules)|Without Remote Signaling|BSPH2A24D24LV|BSPH2A48D48LV|BSPH2A60D60LV|BSPH2A150D150LV|BSPH2A230D230LV|
||With Remote Signaling|BSPH2A24D24LVR|BSPH2A48D48LVR|BSPH2A60D60LVR|BSPH2A150D150LVR|BSPH2A230D230LVR|
|Replacement Modules||BPHA24D24LV|BPHA48D48LV|BPHA60D60LV|BPHA150D150LV|BPHA230D230LV|
||Specifications||||||
|Nominal AC voltage [Vo]||24V|48V|60V|120V|230V|
|Max. continuous operating AC voltage [VC]||30V|60V|75V|150V|255V|
|Max. continuous operating DC voltage [VC]||30V|60V|75V|150V|255V|
|Nominal load current AC [IL]||25A|25A|25A|25A|25A|
|Nominal discharge current (8/20 μs) [In]||1kA|1kA|2kA|2kA|3kA|
|Total discharge current (8/20 μs) [L+N-Gnd] [Itotal]||2kA|2kA|4kA|4kA|5kA|
|Combined impulse [UOC]||2kV|2kV|4kV|4kV|6kV|
|Combined impulse [L+N-Gnd] [UOCtotal]||4kV|4kV|8kV|8kV|10kV|
|Voltage protection level [L-N] [VPR]||_< 180V|_< 350V|_< 400V|_< 640V|_< 1250V|
|Voltage protection level [L/N-Gnd] [VPR]||_< 630V|_< 730V|_< 730V|_< 800V|_< 1500V|
|Temporary overvoltage (TOV) [L-N]||--|--|--|--|335V / 5 sec.|
|Temporary overvoltage (TOV) [L/N-Gnd]||--|--|--|--|400V / 5 sec.|
|Temporary overvoltage (TOV) [L+N-Gnd]||--|--|--|--|1200V + V0/ 20|
|TOV characteristics [L-N]||--|--|--|--|Withstand|
|TOV characteristics [L/N-Gnd]||--|--|--|--|Withstand|
|TOV characteristics [L+N-Gnd]||--|--|--|--|Failure|
|SPD according to EN 61643-11||Type 3|||||
|SPD according to IEC 61643-1||Class III|||||
|Response time [L-N] [tA]||_< 25 ns|||||
|Response time [L/N-Gnd] [tA]||_< 100 ns|||||
|Operating temperature range [TU]||-40°C to +80°C|||||
|Operating state/fault indication||Green (good) / Red (replace)|||||
|Number of ports||1|||||
|Cross-sectional area (min.)||0.5mm2/18AWG solid/flexible|||||
|Cross-sectional area (max.)||4mm2/10AWG solid/2.5mm2/12AWG flexible|||||
|For mounting on||35mm DIN rail per EN 60715|||||
|Enclosure material||Thermoplastic, UL 94V0|||||
|Location category||Indoor|||||
|Degree of protection||IP20|||||
|Capacity||1 Mod., DIN 43880|||||
|Agency Information*||UL / cUL, CSA, KEMA|||||
|Product Warranty||Five Years**|||||
|Remote Contact Signaling|||||||
|Remote Contact Signaling Type||Changeover Contact|||||
|AC Switching Capacity (Volts/Amps)||250V/0.5A|||||
|DC Switching Capacity (Volts/Amps)||250V/0.1A; 125V/0.2A; 75V/0.5A|||||
|Conductor Ratings and Cross-Sectional Area for<br>Remote Contact Signal Terminals||60/75°C Max. 1.5mm2/14AWG Solid/Flexible|||||
|Ordering Information||Order from Catalog Numbers Above|||||
- Standards information not applicable to DC ratings.
** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**Data Sheet: 2057**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**460**
**Overvoltage Devices**
## **IEC Class I DIN-Rail SPD**
## **BSPS_ _ _ _TN, BSPS_ _ _ _TT**
**==> picture [198 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>easy 2)<br>**----- End of picture text -----**<br>
## **Description**
The Bussmann IEC Class I 230V, two-pole, modular combined lightning, current and surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.230V models are offered with MCOV rating of 255V.
## **Dimensions - mm**
**==> picture [185 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shown with optional remote contact signaling<br>**----- End of picture text -----**<br>
## **Circuit Diagrams**
**==> picture [88 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
Creepage Discharge Spark Gap<br>Spark Gap Trigger<br>**----- End of picture text -----**<br>
## **TN System Arresters**
The features of these two-pole devices are for use as a modular combined lightning and current arrester and surge arrester for use in single TN- systems (“2-0” circuit).
## **TT System Arrester**
Provides a current arresting means for use in single TT- systems (“1-1” circuit).
## **Remote Signaling Contact**
**==> picture [68 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
BSPS2255TT<br>**----- End of picture text -----**<br>
**BSPS2255TN**
Shown with optional Shown with optional remote contact signaling remote contact signaling
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPS2255TNR
**Data Sheet: 1163**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**461**
**Overvoltage Devices**
## **IEC Class I DIN-Rail SPD**
|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|
|---|---|---|---|---|---|---|---|---|
|System Voltage/Poles||||||230V/2|230V/2||
|Max.Continuous operatingACvoltage (MCOV) [UC]||||||255V|255V||
|Catalog Numbers:|||WithoutRemote Signaling|||BSPS2255TN|BSPS2255TT||
||||With Remote Signaling|||BSPS2255TNR|BSPS2255TTR||
|Replacement Modules:|||MOVtechnology|||(2X)BPS255IEC|(1X)BPS255IEC||
||||SparkGap technology|||- -|(1X)BPS50NPEIEC*||
||||Specifications||||||
|Specific energy [L+N-PE] [W/R]||||||625.00kJ/ohms|- -||
|Lightningimpulse current (10/350 μs) [L,N-PE] [Iimp]||||||25kA|25/50kA Is [L-N]/[N-PE]||
|Specific energy [L,N-PE] [W/R]||||||156.25 kJ/ohms|<br>156.25kJ/ohms/<br>625.00kJ/ohms||
|Voltage protection level[L-PE]/[N-PE] [UP]||||||<_1.5kV/<_1.5kV|- -||
|Voltage protection level[L-N]/[N-PE] [UP]||||||- -|<_1.5kV/<_1.5kV||
|Followcurrent extinguishing capabilityAC [Ifi]||||||50kA rms|- -||
|Followcurrent extinguishing capability [L-N]/[N-PE] [Ifi]||||||- -|50kA rms/100A rms||
|Temporary overvoltage (TOV) [N-PE] [UT]||||||- -|1200V/200ms||
|SPDaccording toEN61643-11/... IEC 61643-1||||||Type1/ClassI|||
|Energy-coordinated protectioneffectwith regard to the terminalequipment||||||Type1 + Type2|||
|Energy-coordinated protectioneffectwith regard to the terminalequipment (<_ 5m)||||||Type1 + Type2 + Type 3|||
|Nominal ACvoltage [UN]||||||230V|||
|Lightningimpulse current (10/350 μs) [L+N-PE] [Itotal]||||||50kA|||
|Nominaldischarge current (8/20 μs) [In]||||||25/50kA|||
|Followcurrentlimitation/Selectivity||||||no tripping ofa20AgL/gGfuse up to 50kA rms (prosp.)|||
|Response time [tA]||||||<_100ns|||
|Max. Backupfuse (L) up toIK<_ 50kA rms||||||315AgL/gG|||
|Max. Backupfuse (L)for IK> 50kA rms||||||200AgL/gG|||
|Max. Backupfuse (L-L)||||||125AgL/gG|||
|Temporary overvoltage (TOV) [L-N] [UT]||||||440V/5 sec.|||
|TOVcharacteristics||||||withstand|||
|Operating temperaturerange (parallelconnection) [TUP]||||||-40°C to+80°C|||
|Operating temperaturerange (series connection) [TUS]||||||-40°C to+60°C|||
|Operating temperaturerange [parallel]/[continuity] [TU]||||||-40°C to+80°C/-40°C to+60°C|||
|Operating state/faultindication||||||green(good)/red (replace)|||
|Numberofports||||||1|||
|Cross-sectionalarea (L,L,N,N,PE,<br>) [min.]||||||10mm2 solid/flexible|||
|Cross-sectionalarea (L,N,PE) [max.]||||||50mm2/1AWG stranded-35mm2/2AWGflexible|||
|Cross-sectionalarea (L,N,<br>) [max.]||||||35mm2/2AWG stranded-25mm2/4AWGflexible|||
|For mounting on||||||35mm DIN Railper EN60715|||
|Enclosurematerial||||||Thermoplastic, UL94V0|||
|Locationcategory||||||Indoor|||
|Degree ofprotection||||||IP20|||
|Capacity||||||4 mods.,DIN 43880|||
|StandardsInformation||||||KEMA|||
|ProductWarranty||||||FiveYears**|||
|Remote Contact Signaling|||||||||
|Remote Contact SignalingType||||||ChangeoverContact|||
|AC Switching Capacity (Volts/Amps)||||||250V/0.1A|||
|DC Switching Capacity (Volts/Amps)||||||250V/0.1A;125V/0.2A;75V/0.5A|||
|Conductor Ratings and Cross-Sectional Areafor Remote Contact Signal Terminals||||||60/75°CMax. 1.5mm2/14AWG Solid/Flexible|||
|Ordering Information||||||Order from Catalog Numbers Above|||
|Recommended Bussmann NH DIN Size Back Up Fuses|||||* N-PE Surge arrester for location between neutral conductor and protective conductor<br>in TT systems.<br>** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperb<br>mann.com/surge.<br>**Data Sheet: 1**|||uss-<br>**163**|
|Size|NH FusePartNumber|Size||NH FusePartNumber|||||
|00|125NHG00B(max L-L)|02||125NHG02B(max L-L)|||||
|0|125NHG0B(max L-L)|02||200NHG02B(max L Ik>50kA)|||||
|01|125NHG01B(max L-L)|2||315NHG2B(max L_<50kA)|||||
|1|200NHG1B (max L Ik >50kA)|03||315NHG03B (max L _<50kA)|||||
|Size|Recommended Bussmann NH DIN Size Back Up Fuses<br>NH FusePartNumber<br>Size<br>NH FusePartNumber|Recommended Bussmann NH DIN Size Back Up Fuses<br>NH FusePartNumber<br>Size<br>NH FusePartNumber|Recommended Bussmann NH DIN Size Back Up Fuses<br>NH FusePartNumber<br>Size<br>NH FusePartNumber|* N-PE Surge arrester for location between neutral conductor and protective conductor<br>in TT systems.<br>** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperb|
|---|---|---|---|---|
|00|125NHG00B(max L-L)|02|125NHG02B(max L-L)|mann.com/surge.|
|0|125NHG0B(max L-L)|02|200NHG02B(max L Ik>50kA)||
|01|125NHG01B(max L-L)|2|315NHG2B(max L_<50kA)||
|1|200NHG1B (max L Ik >50kA)|03|315NHG03B (max L _<50kA)|**Data Sheet: 1**|
- ** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**Data Sheet: 1163**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**462**
**Overvoltage Devices**
## **IEC Class I DIN-Rail SPD**
## **BSPS_ _ _ _TNC**
**==> picture [198 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>can 2) [)]<br>**----- End of picture text -----**<br>
## **Dimensions - mm**
Shown with optional remote contact signaling
## **Circuit Diagrams**
## **Description**
The Bussmann IEC Class I 230V, three-pole, modular combined lightning, current and surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
230V models are offered with a MCOV rating of 255V.
## **TNC System Arrester**
The features of these three-pole devices are for use in TN-C 230/400V systems (“3-0” circuit) against surges.
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
## **BSPS3255TNC**
Shown with optional remote contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPS3255TNCR
**Data Sheet: 1164**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**463**
**Overvoltage Devices**
## **IEC Class I DIN-Rail SPD**
|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|
|---|---|---|---|---|
|System Voltage/Poles||||230/400V/3|
|Max.Continuous operatingACvoltage (MCOV) [UC]||||255V|
|Catalog Numbers:||WithoutRemote Signaling||BSPS3255TNC|
|||With Remote Signaling||BSPS3255TNCR|
|ReplacementModule||MOVtechnology||BPS255IEC|
|||Specifications|||
|SPDaccording toEN61643-11/... IEC 61643-1||||Type1/ClassI|
|Energy-coordinated protectioneffectwith regard to the terminalequipment||||Type1 + Type2|
|Energy-coordinated protectioneffectwith regard to the terminalequipment (<_ 5m)||||Type1 + Type2 + Type 3|
|Nominal ACvoltage [UN]||||230/400V|
|Lightningimpulse current (10/350 μs) [L1+L2+L3-PEN] [Itotal]||||75kA|
|Specific energy [L1+L2+L3-PEN] [W/R]||||1.40MJ/ohms|
|Lightningimpulse current (10/350 μs) [L-PEN] [Iimp]||||25kA|
|Specific energy [L-PEN] [W/R]||||156.25kJ/ohms|
|Nominaldischarge current (8/20 μs) [In]||||25/75kA|
|Voltage protection level[UP]||||<_1.5kV|
|Followcurrent extinguishing capabilityAC [Ifi]||||50kA rms|
|Followcurrentlimitation/Selectivity||||no tripping ofa20AgL/gGfuse up to 50kA rms (prosp.)|
|Response time [tA]||||<_100ns|
|Max. Backupfuse (L) up toIK=50kA rms||||315AgL/gG|
|Max. Backupfuse (L)for IK> 50kA rms||||200AgL/gG|
|Max. Backupfuse (L-L)||||125AgL/gG|
|Temporary overvoltage (TOV) [UT]||||440V/5 sec.|
|TOVcharacteristics||||withstand|
|Operating temperaturerange [parallel]/[continuity] [TU]||||-40°C to+80°C/-40°C to+60°C|
|Operating state/faultindication||||green(good)/red (replace)|
|Numberofports||||1|
|Cross-sectionalarea(L1L1L2L2L3L3PEN|||)[min]|10mm2 solid/flexible|
|, , , , , , ,<br> .<br>Cross-sectionalarea (L1,L2,L3,PEN) [max.]||||<br>50mm2/1AWG stranded-35mm2/2AWGflexible|
|Cross-sectionalarea(L1L2L3|)[max]|||35mm2/2AWGstranded-25mm2/4AWGflexible|
|, , ,<br> .<br>Mounting||||<br>35mm DIN railpertoEN60715|
|Enclosurematerial||||Thermoplastic, UL94V0|
|Locationcategory||||Indoor|
|Degree ofprotection||||IP20|
|Capacity||||6mods.,DIN 43880|
|StandardsInformation||||KEMA|
|ProductWarranty||||FiveYears*|
|Remote Contact Signaling|||||
|Remote Contact SignalingType||||ChangeoverContact|
|AC Switching Capacity (Volts/Amps)||||250V/0.1A|
|DC Switching Capacity (Volts/Amps)||||250V/0.1A;125V/0.2A;75V/0.5A|
|Conductor Ratings and Cross-Sectional Areafor Remote Contact Signal Terminals||||60/75°CMax. 1.5mm2/14AWG Solid/Flexible|
|Ordering Information||||Order from Catalog Numbers Above|
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [271 x 74] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann NH DIN Size Back Up Fuses<br>Size NH Fuse Part Number Size NH Fuse Part Number<br>00 125NHG00B (max L-L) 02 125NHG02B (max L-L)<br>0 125NHG0B (max L-L) 02 200NHG02B (max L Ik >50kA)<br>01 125NHG01B (max L-L) 2 315NHG2B (max L _<50kA)<br>1 200NHG1B (max L Ik >50kA) 03 315NHG03B (max L _<50kA)<br>**----- End of picture text -----**<br>
**Data Sheet: 1164**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**464**
**Overvoltage Devices**
## **IEC Class I DIN-Rail SPD**
## **BSPS_ _ _ _TNS, BSPS_ _ _ _TT**
**==> picture [89 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions - mm<br>**----- End of picture text -----**<br>
Shown with optional remote contact signaling
**==> picture [198 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>can &)<br>**----- End of picture text -----**<br>
## **Circuit Diagrams**
Creepage Discharge Spark Gap
Spark Gap Trigger
## **Description**
The Bussmann IEC Class I 230V, four-pole, modular combined lightning, current and surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
230V models are offered with MCOV ratings of 255V.
## **TNS System Arresters**
The features of these four-pole devices are for use in TNS 230/400V systems (“4-0” circuit) against surges.
## **TT System Arrester**
## **BSPS4255TNS**
Shown with optional remote contact signaling
Provides a current arresting means between neutral conductor and protective conductor in TT 230/400V systems (“3+1” circuit) against surges.
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
## **BSPS4255TT**
Shown with optional remote contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPS4255TTR
**Data Sheet: 1165**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**465**
**Overvoltage Devices**
## **IEC Class I DIN-Rail SPD**
|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|
|---|---|---|---|---|---|
|System Voltage/Poles||||230/400V/4|230/400V/4|
|Max.Continuous operatingACvoltage (MCOV) [UC]||||255V|255V|
|Catalog Numbers:||WithoutRemote Signaling||BSPS4255TNS|BSPS4255TT|
|||With Remote Signaling||BSPS4255TNSR|BSPS4255TTR|
|Replacement Modules:||MOVtechnology||BPS255IEC|BPS255IEC|
|||SparkGap technology||- -|BPS100NPEIEC*|
|||Specifications||||
|SPDaccording toEN61643-11/... IEC 61643-1||||Type1/ClassI||
|Energy-coordinated protectioneffectwith regard to the terminalequipment||||Type1 + Type2||
|Energy-coordinated protectioneffectwith regard to the terminalequipment (<_ 5m)||||Type1 + Type2 + Type 3||
|Nominal ACvoltage [UN]||||230/400V||
|Lightningimpulse current (10/350 μs) [L1+L2+L3+N-PE] [Itotal]||||100kA||
|Specific energy [L1+L2+L3+N-PE] [W/R]||||2.50MJ/ohms||
|Lightningimpulse current (10/350 μs) [L,N-PE] [Iimp]||||25kA||
|TNS systemspecific energy [L,N-PE] [W/R]||||156.25kJ/ohms||
|TTsystemspecific energy [L-N]/[N-PE] [W/R]||||156.25kJ/ohms/2.50kJ/ohms||
|Nominaldischarge current (8/20 μs) [In]||||25/100kA||
|Voltage protection level[L-PE]/[N-PE] [UP]||||<_1.5kV/<_1.5kV||
|TNS system followcurrent extinguishing capabilityAC [Ifi]||||50kA rms||
|TTsystem followcurrent extinguishing capabilityAC [Ifi]||||50kA rms/100A rms||
|Followcurrentlimitation/Selectivity||||No tripping ofa20AgL/gGfuse up to 50kA rms (prosp.)||
|Response time [tA]||||<_100ns||
|Max. Backupfuse (L) up toIK <_ 50kA rms||||315AgL/gG||
|Max. Backupfuse (L)for IK > 50kA rms||||200AgL/gG||
|Max. Backupfuse (L-L)||||125AgL/gG||
|Temporary overvoltage (TOV) [L-N] [UT]||||440V/5 sec.||
|Temporary overvoltage (TOV) [N-PE] [UT]||||1200V/200mS||
|TOVcharacteristics||||Withstand||
|Operating temperaturerange [parallel]/[continuity] [TU]||||-40°C to+80°C/-40°C to+60°C||
|Operating state/faultindication||||green(good)/red (replace)||
|Numberofports||||1||
|Cross-sectionalarea(L1L1L2L2L3L3NNPE|||)[min]|10mm2 solid/flexible||
|, , , , , , , , ,<br> .<br>Cross-sectionalarea (L1,L2,L3,N,PE) [max.]||||<br>50mm2/1AWG stranded-35mm2/2AWGflexible||
|Cross-sectionalarea(L1L2L3N|)[max]|||35mm2/2AWGstranded-25mm2/4AWGflexible||
|, , , ,<br> .<br>Mounting||||<br>35mm DIN Railper EN60715||
|Enclosurematerial||||Thermoplastic, UL94V0||
|Locationcategory||||Indoor||
|Degree ofprotection||||IP20||
|Capacity||||8mods.,DIN 43880||
|AgencyInformation||||KEMA||
|ProductWarranty||||FiveYears**||
|Remote Contact Signaling||||||
|Remote Contact SignalingType||||ChangeoverContact||
|AC Switching Capacity (Volts/Amps)||||250V/0.1A||
|DC Switching Capacity (Volts/Amps)||||250V/0.1A;125V/0.2A;75V/0.5A||
|Conductor Ratings and Cross-Sectional Areafor Remote Contact Signal Terminals||||60/75°CMax. 1.5mm2/14AWG Solid/Flexible||
|Ordering Information||||Order from Catalog Numbers Above||
* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [271 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann NH DIN Size Back Up Fuses<br>Size NH Fuse Part Number Size NH Fuse Part Number<br>00 125NHG00B (max L-L) 02 125NHG02B (max L-L)<br>0 125NHG0B (max L-L) 02 200NHG02B (max L Ik >50kA)<br>01 125NHG01B (max L-L) 2 315NHG2B (max L _<50kA)<br>1 200NHG1B (max L Ik >50kA) 03 315NHG03B (max L _<50kA)<br>**----- End of picture text -----**<br>
**Data Sheet: 1165**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**466**
**Overvoltage Devices**
## **IEC Class II DIN-Rail SPD**
## **BSPM_ _ _ _TN, BSPG_ _ _ _NPE**
**==> picture [198 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>easy|ID™ ei<br>**----- End of picture text -----**<br>
## **Description**
## **Dimensions - mm**
Shown with optional remote contact signaling 7
## **Module Circuit Diagrams -**
Shown with optional remote contact signaling
The Bussmann IEC Class II 275, 320, 385, 440 and 600V, one-pole, modular surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module. Class II single-pole surge arrester models are offered with MCOV ratings of 255, 275, 320, 385, 440 and 600V.
## **TN System Arresters**
The features of these single-pole devices are for use as a single device or in combination with other devices.
## **TT System Arrester**
Provides a current arresting means between neutral conductor and protective conductor in TT systems, this device helps ensure fulfilling the requirements for protection of personnel and equipment in “3+1” and “1+1” circuits.
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
**==> picture [77 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
MOV<br>Thermal Disconnector<br>Gas Discharge Tube (single)<br>**----- End of picture text -----**<br>
## **BSPM1275TN BSPM1320TN BSPG1255NPE(R) BSPM1385TN BSPM1440TN BSPM1600TN**
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPM1275TNR
**Data Sheet: 1166**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**467**
**Overvoltage Devices**
## **IEC Class II DIN-Rail SPD**
|Ordering Information|Ordering Information|Ordering Information|Ordering Information|Ordering Information|Ordering Information|Ordering Information|Ordering Information|Ordering Information|Ordering Information|
|---|---|---|---|---|---|---|---|---|---|
|System Voltage/Poles||||230V/1|230V/1|230V/1|400V/1|600V/1|230V/1*|
|Max. Continuous operating AC voltage (MCOV) [UC]||||275V|320V|385V|440V|600V|255V|
|Catalog Numbers:<br>WithoutRemote Signaling<br>(Base + Modules)<br>With Remote Signaling||Remote Signaling||BSPM1275TN|BSPM1320TN|BSPM1385TN|BSPM1440TN|BSPM1600TN|BSPG1255NPE|
|||||BSPM1275TNR|BSPM1320TNR|BSPM1385TNR|BSPM1440TNR|BSPM1600TNR|BSPG1255NPER|
|Replacement Modules||||BPM275IEC|BPM320IEC|BPM385IEC|BPM440IEC|BPM600IEC|BPG255NPE|
|Specifications||||||||||
|Line system type||||TN / TT|TN / TT|TN / TT|TN|TN|TT|
|Max. Continuous operating DC voltage [UC]||||350V|420V|500V|585V|600V|- -|
|Voltage protection level [UP]||||<_ 1.25kV|<_ 1.5kV|<_ 1.75kV|<_ 2kV|<_ 2.5kV|<_ 1.5kV|
|Voltage protection level at 5kA [UP]||||<_ 1kV|<_ 1.2kV|<_ 1.35kV|<_ 1.7kV|<_ 2kV|- -|
|Max. mains-side overcurrent protection||||125A gL/gG|125A gL/gG|125A gL/gG|125A gL/gG|100A gL-gG|- -|
|Short-circuit withstand capability for max.<br>mains-side overcurrent protection||||50kArms|25kArms|25kArms|25kArms|25kA rms|- -|
|Temporary overvoltage (TOV) [UT]||||335V/5 sec.|335V/5 sec.|385V/5 sec.|580V/5 sec.|600V/5 sec.|1200V/200 ms|
|Response time [tA]||||<_ 25 ns|<_ 25 ns|<_ 25 ns|<_ 25 ns|<_ 25 ns|<_ 100 ns|
|Follow current extinguishing capability [Ifi]||||- -|- -|- -|- -|- -|100Arms|
|Lightning impulse current (10/350 μs) [Iimp]||||- -|- -|- -|- -|- -|12kA|
|Nominal discharge current (8/20 μs) [In]||||20kA|20kA|20kA|20kA|15kA|20kA|
|Max. Discharge current (8/20 μs) [Imax]||||40kA|40kA|40kA|40kA|30kA|40kA|
|Standards Information||||KEMA|KEMA, CSA|KEMA, CSA|KEMA, CSA|KEMA, CSA|KEMA|
|Capacity||||1 mod., DIN 43880||||||
|SPD according to EN 61643-11||||Type 2||||||
|SPD according to IEC 61643-1||||Class II||||||
|TOV characteristics||||Withstand||||||
|Operating temperature range [TU]||||-40°C to +80°C||||||
|Operating state/fault indication||||Green (good) / Red (replace)||||||
|Number of ports||||1||||||
|Cross-sectional area (min.)||||1.5mm2/14AWG solid/flexible||||||
|Cross-sectional area (max.)||||35mm2/2AWG stranded-25mm2/4AWG flexible||||||
|Mounting||||35mm DIN Rail per EN 60715||||||
|Enclosure material||||Thermoplastic, UL 94V0||||||
|Location category||||Indoor||||||
|Degree of protection||||IP20||||||
|Product Warranty||||Five Years**||||||
|Remote Contact Signaling||||||||||
|Remote Contact Signaling Type||||Changeover Contact||||||
|AC Switching Capacity (Volts/Amps)||||250V/0.1A||||||
|DC Switching Capacity (Volts/Amps)||||250V/0.1A; 125V/0.2A; 75V/0.5A||||||
|Conductor Ratings and Cross-Sectional Area for<br>Remote Contact Signal Terminals||||60/75°C Max. 1.5mm2/14AWG Solid/Flexible||||||
|Ordering Information||||Order from Catalog Numbers Above||||||
|* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.<br>** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.<br>Recommended Bussmann Back Up Fuses<br>DIN<br>TT/TNSystem NH FusePartNumbers<br>Fuse Size<br>275, 320, 385,440V<br>600V<br>00<br>125NHG00B<br>100NHG00B-690<br>0<br>125NHG0B<br>100NHG0B-690<br>01<br>125NHG01B<br>- -<br>1<br>- -<br>100NHG1B-690<br>02<br>125NHG02B<br>- -<br>2<br>- -<br>100NHG2B-690||||||||||
|Recommended Bussmann Back Up Fuses||||||||||
|DIN<br>Fuse Size|TT/TNSystem NH FusePartNumbers|||||||||
||275, 320, 385,440V||600V|||||||
|00|125NHG00B||100NHG00B-690|||||||
|0|125NHG0B||100NHG0B-690|||||||
|01|125NHG01B||- -|||||||
|1|- -||100NHG1B-690|||||||
|02|125NHG02B||- -|||||||
|2|- -||100NHG2B-690|||||||
* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [240 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann Back Up Fuses<br>DIN TT / TN System NH Fuse Part Numbers<br>Fuse Size 275, 320, 385, 440V 600V<br>00 125NHG00B 100NHG00B-690<br>0 125NHG0B 100NHG0B-690<br>01 125NHG01B - -<br>1 - - 100NHG1B-690<br>02 125NHG02B - -<br>2 - - 100NHG2B-690<br>**----- End of picture text -----**<br>
**Data Sheet: 1166**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**468**
**Overvoltage Devices**
## **IEC Class II DIN-Rail SPD**
## **BSPM_ _ _ _TN, BSPH_ _ _ _TT**
## **Dimensions - mm**
**==> picture [198 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>**----- End of picture text -----**<br>
## **Description**
The Bussmann IEC Class II 230V, two-pole, modular surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.230V models are offered with MCOV ratings of 255 and 275V.
Shown with optional remote contact signaling
## **Circuit Diagrams**
**==> picture [15 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
MOV<br>**----- End of picture text -----**<br>
**==> picture [77 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
Thermal Disconnector<br>Gas Discharge Tube (single)<br>**----- End of picture text -----**<br>
## **TN System Arresters**
The features of these single-pole devices are for use in single-phase 230V TN systems (“2-0” circuit).
## **TT System Arrester**
The features of these single-pole devices are for use in single-phase 230V TT and TNS systems (“1-1” circuit).
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
## **BSPM2275TN**
## **BSPH2275TT**
Shown with optional remote Shown with optional remote contact signaling contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPM2275TNR
**Data Sheet: 1167**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**469**
**Overvoltage Devices**
## **IEC Class II DIN-Rail SPD**
|OrderingInformation|OrderingInformation|OrderingInformation|OrderingInformation|
|---|---|---|---|
|System Voltage/Poles||230V/2|230V/2|
|Max.continuous operatingACvoltage (MCOV) [UC]||275V|- -|
|Max.Continuous operatingACvoltage (MCOV) [L-N] [UC]||- -|275V|
|Max.Continuous operatingACvoltage (MCOV) [N-PE] [UC]||- -|255V|
|Catalog Numbers:|WithoutRemote Signaling|BSPM2275TN|BSPH2275TT|
||With Remote Signaling|BSPM2275TNR|BSPH2275TTR|
|Replacement Modules:|MOV Technology|BPM275IEC|BPM275IEC|
||SparkGap technology|- -|BPSNPEIEC*|
||Specifications|||
|Lightningimpulse current (10/350 μs) [N-PE] [Iimp]||- -|12kA|
|Voltage protection level[UP]||<_1.25kV|- -|
|Voltage protection levelat 5kA[UP]||<_1kV|- -|
|Voltage protection level[L-N] [UP]||- -|<_1.25kV|
|Voltage protection level[L-N] at 5kA[UP]||- -|<_1kV|
|Voltage protection level[N-PE] [UP]||- -|<_1.5kV|
|Followcurrent extinguishing capability [N-PE] [Ifi]||- -|100A rms|
|Response time [tA]||<_25ns|- -|
|Response time [L-N] [tA]||- -|<_25ns|
|Response time [N-PE] [tA]||- -|<_100ns|
|Temporary overvoltage (TOV) [UT]||335V/5 sec.|- -|
|Temporary overvoltage (TOV) [L-N] [UT]||- -|335V/5 sec.|
|Temporary overvoltage (TOV) [N-PE] [UT]||- -|1200V/200ms|
|SPDaccording toEN61643-11||Type2||
|SPDaccording toIEC 61643-1||ClassII||
|Nominaldischarge current (8/20 μs) [In]||20kA||
|Max.discharge current (8/20 μs) [Imax]||40kA||
|Max. mains-side overcurrent protection||125AgL/gG||
|Short-circuitwithstand capabilityfor max. mains-side overcurrent protection||50kA rms||
|Nominal ACvoltage [UN]||230V||
|TOVcharacteristics||withstand||
|Operating temperaturerange [TU]||-40°C to+80°C||
|Operating state/faultindication||green(good)/red (replace)||
|Numberofports||1||
|Cross-sectionalarea (min.)||1.5mm2/14AWG solid/flexible||
|Cross-sectionalarea (max.)||35mm2/2AWG stranded-25mm2/4AWGflexible||
|Mounting||35mm DIN railper EN60715||
|Enclosurematerial||Thermoplastic, UL94V0||
|Locationcategory||Indoor||
|Degree ofprotection||IP20||
|Capacity||2 mods.,DIN 43880||
|StandardsInformation||KEMA||
|ProductWarranty||FiveYears**||
|Remote Contact Signaling||||
|Remote Contact SignalingType||ChangeoverContact||
|AC Switching Capacity (Volts/Amps)||250V/0.1A||
|DC Switching Capacity (Volts/Amps)||250V/0.1A;125V/0.2A;75V/0.5A||
|Conductor Ratings and Cross-Sectional Areafor Remote Contact Signal Terminals||60/75°CMax. 1.5mm2/14AWG Solid/Flexible||
|Ordering Information||Order from Catalog Numbers Above||
* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
- ** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [185 x 74] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann Back Up Fuses<br>DIN Fuse Size NH Fuse Part Number<br>00 125NHG00B<br>0 125NHG0B<br>01 125NHG01B<br>02 125NHG02B<br>**----- End of picture text -----**<br>
**Data Sheet: 1167**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**470**
**Overvoltage Devices**
## **IEC Class II DIN-Rail SPD**
## **BSPM_ _ _ _TNC**
**==> picture [198 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication ni Contact Available<br>easy|ID™<br>**----- End of picture text -----**<br>
## **Description**
The Bussmann IEC Class II 120/240V and 230/400V, three-pole, modular surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module. 120V models are offered with a MCOV rating of 150V. 230V models are offered with a MCOV rating of 275 or 385V.
## **Dimensions - mm**
> Shown with optional remote contact signaling ~
## **Circuit Diagrams**
**==> picture [14 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
MOV<br>**----- End of picture text -----**<br>
**==> picture [60 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Thermal Disconnector<br>**----- End of picture text -----**<br>
## **TNC System Arresters**
The features of these three-pole devices are for use in TN-C 120/240V or 230/400V systems (“3-0” circuit) against surges.
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
## **BSPM3150TNC, BSPM3275TNC, BSPM3385TNC**
Shown with optional remote contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPM3150TNCR
**Data Sheet: 1168**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**471**
**Overvoltage Devices**
## **IEC Class II DIN-Rail SPD**
|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|
|---|---|---|---|
|System Voltage/Poles|120V/3|230V/3|230V/3|
|Max.Continuous operatingACvoltage (MCOV) [UC]|150V|275V|385V|
|Catalog Numbers:<br>Without Remote Signaling<br>With Remote Signaling|BSPM3150TNC|BSPM3275TNC|BSPM3385TNC|
||BSPM3150TNCR|BSPM3275TNCR|BSPM3385TNCR|
|ReplacementModule<br>MOVtechnology|BPM150IEC|BPM275IEC|BPM385IEC|
|SPECIFICATIONS||||
|Nominal ACvoltage [UN]|120/240V|230/400V|230/400V|
|Voltage protection level[UP]|_< 0.7kV|<_1.25kV|_<1.75kV|
|Voltage protection levelat 5kA[UP]|_< 0.55kV|<_1kV|_<1.35kV|
|Short-circuitwithstand capabilityfor max. mains-side overcurrent protection|50kArms|50kArms|25kArms|
|Temporary overvoltage (TOV) [UT]|175V/5 sec|335V/5 sec.|385V/5 sec|
|Nominaldischarge current (8/20 μs) [In]|15kA|20kA|20kA|
|Max. Discharge current (8/20 μs) [Imax]||40kA||
|SPDaccording toEN61643-11|Type2|||
|SPDaccording toIEC 61643-1|ClassII|||
|Response time [tA]|<_25ns|||
|Max. mains-side overcurrent protection|125AgL/gG|||
|TOVcharacteristics|withstand|||
|Operating temperaturerange [TU]|-40°C to+80°C|||
|Operating state/faultindication|Green(good)/Red (replace)|||
|Numberofports|1|||
|Cross-sectionalarea (min.)|1.5mm2/14AWG solid/flexible|||
|Cross-sectionalarea (max.)|35mm2/2AWG stranded-25mm2/4AWGflexible|||
|Mounting|35mm DIN railper EN60715|||
|Enclosurematerial|Thermoplastic, UL94V0|||
|Locationcategory|Indoor|||
|Degree ofprotection|IP20|||
|Capacity|3mods.,DIN 43880|||
|StandardsInformation|KEMA|||
|ProductWarranty|FiveYears*|||
|REMOTE CONTACT SIGNALING||||
|Remote Contact SignalingType|ChangeoverContact|||
|AC Switching Capacity (Volts/Amps)|250V/0.1A|||
|DC Switching Capacity (Volts/Amps)|250V/0.1A;125V/0.2A;75V/0.5A|||
|Conductor Ratings and Cross-Sectional Areafor Remote Contact Signal Terminals|60/75°CMax. 1.5mm2/14AWG Solid/Flexible|||
|Ordering Information|Order from Catalog Numbers Above|||
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [185 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann Back Up Fuses<br>DIN Fuse Size NH Fuse Part Number<br>00 125NHG00B<br>0 125NHG0B<br>01 125NHG01B<br>02 125NHG02B<br>**----- End of picture text -----**<br>
**Data Sheet: 1168**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**472**
**Overvoltage Devices**
## **IEC Class II DIN-Rail SPD**
## **BSPH_TNS, BSPH_TT**
**==> picture [198 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>**----- End of picture text -----**<br>
**Dimensions - mm** 30 ~~PC~~ [| [| ~~-~~ 3 ~~|~~ Shown with optional remote contact signaling
## **Circuit Diagrams**
**==> picture [15 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
MOV<br>**----- End of picture text -----**<br>
Thermal Disconnector Gas Discharge Tube (single)
## **Description**
The Bussmann IEC Class II 230/400V, four-pole, modular surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
These 230V models are offered with MCOV ratings of 275, 320 or 385V.
## **TNS System Arrester**
The features of these four-pole devices are for use in TNS 230/400V systems (“4-0” circuit) against surges.
## **BSPM4275TNS**
Shown with optional remote contact signaling
## **TT System Arrester**
The features of these four-pole devices are for use in TT and TN-S 230/400V systems (“3+1” circuit) against surges.
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
## **BSPH4275TT, BSPH4320TT**
## **BSPH4385TT**
Shown with optional remote contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPH4275TTR
**Data Sheet: 1169**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**473**
**Overvoltage Devices**
## **IEC Class II DIN-Rail SPD**
|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|ORDERINGINFORMATION|
|---|---|---|---|---|---|
|System Voltage/Poles||230V/4|230V/4|230V/4|230V/4|
|Max.continuous operatingACvoltage (MCOV) [UC]||275V|- -|- -|- -|
|Max.continuous operatingACvoltage (MCOV) [L-N] [UC]||- -|275V|320V|385V|
|Max.continuous operatingACvoltage [N-PE] [UC]||- -|255V|255V|255V|
|Catalog Numbers:|WithoutRemote Signaling|BSPM4275TNS|BSPH4275TT|BSPH4320TT|BSPH4385TT|
||With Remote Signaling|BSPM4275TNSR|BSPH4275TTR|BSPH4320TTR|BSPH4385TTR|
|Replacement Modules:|MOVtechnology|BPM275IEC|BPM275IEC|BPM320IEC|BPM385IEC|
||SparkGap technology|- -|BPSNPEIEC*|BPSNPEIEC*|BPSNPEIEC*|
||SPECIFICATIONS|||||
|Lightningimpulse current (10/350 μs) [N-PE] [Iimp]||- -|12kA|12kA|12kA|
|Voltage protection level[UP]||<_1.25kV|- -|- -|- -|
|Voltage protection levelat 5kA[UP]||<_1kV|- -|- -|- -|
|Voltage protection level[L-N] [UP]||- -|<_1.25kV|<_1.5kV|<_1.75kV|
|Voltage protection level[L-N] at 5kA[UP]||- -|<_1kV|<_1.2kV|<_1.35kV|
|Voltage protection level[N-PE] [UP]||- -|<_1.5kV|<_1.5kV|<_1.5kV|
|Followcurrent extinguishing capability [N-PE] [Ifi]||- -|100Arms|100Arms|100Arms|
|Response time [tA]||<_25ns|- -|- -|- -|
|Response time [L-N] [tA]||- -|<_25ns|<_25ns|<_25ns|
|Response time [N-PE] [tA]||- -|<_100ns|<_100ns|<_100ns|
|Temporary overvoltage (TOV) [UT]||335V/5 sec.|- -|- -|- -|
|Temporary overvoltage (TOV) [L-N] [UT]||- -|335V/5 sec.|335V/5 sec.|385V/5 sec.|
|Temporary overvoltage (TOV) [N-PE] [UT]||- -|1200V/200ms|1200V/200ms|1200V/200ms|
|Short-circuit withstand capability for max.<br>mains-side overcurrent protection||50kArms|50kArms|25kArms|25kArms|
|SPDaccording toEN61643-11||Type2||||
|SPDaccording toIEC 61643-1||ClassII||||
|Nominal ACvoltage [UN]||230/400V||||
|Nominaldischarge current (8/20 μs) [In]||20kA||||
|Max.discharge current (8/20 μs) [Imax]||40kA||||
|Max. mains-side overcurrent protection||125AgL/gG||||
|TOVcharacteristics||withstand||||
|Operating temperaturerange [TU]||-40°C to+80°C||||
|Operating state/faultindication||green(good)/red (replace)||||
|Numberofports||1||||
|Cross-sectionalarea (min.)||1.5mm2/14AWG solid/flexible||||
|Cross-sectionalarea (max.)||35mm2/2AWG stranded-25mm2/4AWGflexible||||
|Mounting||35mm DIN railper EN60715||||
|Enclosurematerial||Thermoplastic, UL94V0||||
|Locationcategory||Indoor||||
|Degree ofprotection||IP20||||
|Capacity||4 mods.,DIN 43880||||
|StandardsInformation||KEMA||||
|ProductWarranty||FiveYears**||||
|REMOTE CONTACT SIGNALING||||||
|Remote Contact SignalingType||ChangeoverContact||||
|AC Switching Capacity (Volts/Amps)||250V/0.1A||||
|DC Switching Capacity (Volts/Amps)||250V/0.1A;125V/0.2A;75V/0.5A||||
|Conductor Ratings and Cross-Sectional Areafor Remote Contact Signal Terminals||60/75°CMax. 1.5mm2/14AWG Solid/Flexible||||
|Ordering Information||Order from Catalog Numbers Above||||
- N-PE Surge arrester module for location between neutral conductor and protective conductor in TT systems.
- ** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [185 x 63] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann Back Up Fuses<br>DIN Fuse Size NH Fuse Part Number<br>00 125NHG00B<br>0 125NHG0B<br>01 125NHG01B<br>02 125NHG02B<br>**----- End of picture text -----**<br>
**Data Sheet: 1169**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**474**
**Overvoltage Devices**
## **Photovoltaic DIN-Rail Lightning SPD**
## **BSPS_ _ _ _PV**
## **Dimensions - mm**
## **Module Circuit Diagrams**
## **Description**
The Bussmann combined lightning current and surge arrester (SPD Class I according to IEC 61643-1) is for use in photovoltaic power supply systems.
- Prewired combined lightning current and surge arrester for use in photovoltaic generator circuits
- For use in photovoltaic installations up to 1000V UCPV
- High lightning current discharge capacity using spark gap technology
- Maximum system availability due to spark gap technology with DC current extinction
**Data Sheet: 2148**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**475**
**Overvoltage Devices**
## **Photovoltaic DIN-Rail Lightning SPD**
**==> picture [524 x 333] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering Information<br>Specifications<br>Max. PV System Voltage 1000Vdc<br>Catalog Number: BSPS31000PV<br>SPD Classification according to EN 61643-11 Type 1<br>SPD Classification according to IEC 61643-1 Class I<br>Max. PV voltage [U CPV ] of the PV generator 1000V<br>Max. Continuous operating DC voltage [U max DC] 1000V<br>Min. Continuous operating DC voltage [U min DC] 100V<br>Follow current extinguishing capability DC [I fi DC] 100A<br>Nominal discharge current (8/20 μs) [I n ] 100kA<br>Lightning impulse current (10/350 μs) [L+/L- -> PE] [I imp ] 50kA<br>Specific energy [L+/L- -> PE] [W/R] 625.00 kJ/ohms<br>Lightning impulse current (10/350 μs) [L+ -> L-] [I imp ] 25kA<br>Specific energy [L+ -> L-] [W/R] 156.25 kJ/ohms<br>Voltage protection level [L+ -> L-] [U p ] _< 3.3kV<br>- -<br>Voltage protection level [(L+/L ) > PE] [U p ] _< 4kV<br>Operating current [I IN DC] _< 5mA<br>Response time [L+ -> L-] [t A ] _< 20 ns<br>Protective conductor current [I PE ] _< 1μA<br>Operating temperature range [T u ] -40°C to +60°C<br>Number of ports 1<br>Cross-sectional area (min.) 10mm2/6AWG solid/flexible<br>Cross-sectional area (max.) 50mm2/2AWG stranded/ 35mm2/1AWG flexible<br>Mounting 35mm DIN rail per EN 60715<br>Enclosure material Thermoplastic, UL 94V0<br>Place of installation Indoor<br>Degree of protection IP-20<br>Capacity 8 Mods., DIN 4<br>Product Warranty Five Years*<br>**----- End of picture text -----**<br>
* See Bussmann document 3A1502 on the web at www.cooperbussmann.com.
**==> picture [143 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
L+ L-<br>**----- End of picture text -----**<br>
**Data Sheet: 2148**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**476**
**Overvoltage Devices**
## **Photovoltaic DIN-Rail SPD**
## **BSPH2_ _ _ _PV**
**==> picture [199 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>cosy” (=)<br>**----- End of picture text -----**<br>
## **Dimensions - mm**
Shown with optional remote contact signaling
## **Module Circuit Diagrams**
## **Description**
The Bussmann modular Surge Protective Device (SPD) (with two-step DC switching device) features _easy_ ID™ visual indication and optional remote contact signaling (floating changeover contact) for use in photovoltaic systems.
This complete surge protective device is suitable for all PV systems in accordance with UL 1449 3[rd] Edition and IEC 60364-7-712. Includes a five year limited warranty.
This prewired solution consist of a base and locking modules that feature a combined disconnection and short-circuiting (shunting) device with safe electrical isolation to prevent fire damage due to DC arcs. An integrated DC fuse allows safe module replacement without arc formation.
In case of insulation faults in the generator circuit, a reliable and tested fault-resistant circuit prevents damage to the surge protective devices.
The green and red visual indicator flags show the module protective status (green = good, red = replace). Apart from this visual indication, the remote signaling option features a three terminal floating changeover contact that can be used as a make or break contact depending on the particular monitoring system design employed.
**==> picture [60 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse Closed<br>Fuse Open<br>MOV<br>Thermal Disconnector<br>Arc<br>**----- End of picture text -----**<br>
## **BSPH2600PV***
Shown with optional remote contact signaling
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPH2600PVR
## **Short-Circuit Interrupting (SCI) Technology**
1. Original State 2. Disconnection Device Response
3. Arc Extinguishes 4. Safe Electrical Isolation
**==> picture [227 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3 4<br>**----- End of picture text -----**<br>
**Data Sheet: 2145**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**477**
**Overvoltage Devices**
## **Photovoltaic DIN-Rail SPD**
**==> picture [523 x 398] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering Information<br>Nominal PV System Voltage 600Vdc<br>Catalog Numbers: Without Remote Signaling BSPH2600PV<br>(Base + Modules) With Remote Signaling BSPH2600PVR<br>Replacement Modules: Left BPH300YPV<br>Right BPM300YPV<br>Specifications<br>Conformity with prEN 50539-11 Yes<br>SPD Classification per EN 61643-11 Type 2<br>SPD Classification per IEC 61643-1 Class II<br>Max. PV voltage [UCPV] _< 600V<br>Short-circuit withstand capacity [ISCWPV] 1000A<br>MCOV [UCPV] 700Vdc<br>Nominal discharge current (8/20 μs) [(DC+/DC-) --> PE] [In] 12.5kA<br>Max. Discharge current (8/20 μs) [(DC+/DC-) --> PE] [Imax] 25kA<br>Voltage protection level [UP] _< 2.5kV<br>Voltage protection level at 5kA [UP] _< 2kV<br>Response time [tA] _< 25 ns<br>Operating temperature range [TU] -40°C to +80°C<br>Operating state/fault indication Green (good) / Red (replace)<br>Number of ports 1<br>Cross-sectional area (min.) 60/75°C 1.5mm [2] /14AWG Solid/Flexible<br>Cross-sectional area (max.) 60/75°C 35mm [2] /2AWG Stranded/25mm [2] /4AWG Flexible<br>For mounting on 35 mm DIN rail per EN 60715<br>Enclosure material Thermoplastic, UL 94V0<br>Place of installation Indoor<br>Degree of protection IP20<br>Capacity 2 Modules, DIN 43880<br>Standards Information UL<br>Product Warranty Five Years*<br>Remote Contact Signaling<br>Remote Contact Signaling Type Changeover Contact<br>AC Switching Capacity (Volts/Amps) 250V/0.1A<br>DC Switching Capacity (Volts/Amps) 250V/0.1A; 125V/0.2A; 75V/0.5A<br>Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals 60/75°C Max. 1.5mm [2] /14AWG Solid/Flexible<br>Ordering Information Order from Catalog Numbers Above<br>**----- End of picture text -----**<br>
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
Typical Application Schematic
**==> picture [260 x 204] intentionally omitted <==**
**Data Sheet: 2145**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**478**
**Overvoltage Devices** Bg
## **Photovoltaic DIN-Rail SPD**
## **BSPH_ _ _ _YPV**
## **Dimensions - mm**
**==> picture [186 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shown with optional remote contact signaling<br>**----- End of picture text -----**<br>
**==> picture [199 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>“e@<br>**----- End of picture text -----**<br>
## **Description**
The Bussmann three-module photovoltaic Surge Protective Device (SPD) (with three-step DC switching device) features _easy_ ID™ visual indication and optional remote contact signaling (floating changeover contact) for use in PV systems.
These complete surge protective devices are suitable for all PV systems in accordance with UL 1449 3[rd] Edition and IEC 60364-7-712. Includes a five year limited warranty.
These prewired solutions consist of a base and locking modules that feature a combined disconnection and short-circuiting (shunting) device with safe electrical isolation to prevent fire damage due to DC arcs. An integrated DC fuse allows safe module replacement without arc formation.
In case of insulation faults in the generator circuit, a reliable and tested fault-resistant Y circuit prevents damage to the surge protective devices.
## **Module Circuit Diagrams**
**==> picture [250 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC+/– DC–/+<br>12<br>11 Fuse Closed<br>14<br>Fuse Open<br>MOV<br>Thermal Disconnector<br>Arc<br>BSPH_____YPV*<br>Shown with optional remote contact signaling<br>**----- End of picture text -----**<br>
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPH____YPVR
The green and red visual indicator flags show the module protective status (green = good, red = replace). Apart from this visual indication, the remote signaling option features a three terminal floating changeover contact that can be used as a make or break contact depending on the particular monitoring system design employed.
## **Short-Circuit Interrupting (SCI) Technology**
1. Original State 2. Disconnection Device Response
3. Arc Extinguishes 4. Safe Electrical Isolation
1 2 3 4
**Data Sheet: 2055**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**479**
**Overvoltage Devices**
## **Photovoltaic DIN-Rail SPD**
**==> picture [523 x 362] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering Information<br>Nominal PV System Voltage 600Vdc 1000Vdc 1200Vdc<br>Catalog Numbers: Without Remote Contact Signaling BSPH3600YPV BSPH31000YPV BSPH31200YPV<br>(Base + Modules) With Remote Contact Signaling BSPH3600YPVR BSPH31000YPVR BSPH31200YPVR<br>Replacement Modules: Outer (2 modules installed) BPH300YPV BPH500YPV BPH600YPV<br>Center (1 module installed) BPM300YPV BPM500YPV BPM600YPV<br>Specifications<br>Nominal PV System Voltage 600V 1000V 1200V<br>MCOV [U CPV ] 700Vdc 1170Vdc 1200Vdc<br>Max System Discharge Current (8/20 μs) [Imax] 40kA 40kA 30kA<br>Voltage Protection Level [U P ] <_2.5kV <_4.0kV <_4.5kV<br>Voltage Protection Level at 5kA [U P ] <_2.0kV <_3.5kV <_4.0kV<br>Integrated Fuse Breaking Capacity/Interrupting Rating 30kA / 1000Vdc 30kA / 1000Vdc 30kA / 1200Vdc<br>Technology Short-Circuit Interruption (SCI) Overcurrent Protection<br>Operating Temperature Range [T U ] -40°C to +80°C<br>Nominal Discharge Current (8/20 μs) [(DC+/DC-) --> PE] [I n ] 12.5kA<br>Response Time [t A ] <_25ns<br>Operating State/Fault Indication Green (good) / Red (replace)<br>Conductor Ratings and Cross-Sectional Area: Minimum 60/75°C 1.5mm [2 ] / 14AWG Solid/Flexible<br>Maximum 60/75°C 35mm [2 ] / 2AWG Stranded / 25mm [2 ] / 4AWG Flexible<br>Mounting 35mm DIN Rail per EN 60715<br>Enclosure Material UL 94V0 Thermoplastic<br>Degree of Protection IP20<br>Capacity 3 Modules, DIN 43880<br>Standards Information: UL UL 1449 3 [rd] Edition (Type 2)*<br>IEC IEC 61643-11 Type 2, IEC 61643-1 Class II<br>Product Warranty Five Years**<br>Remote Contact Signaling<br>Remote Contact Signaling Type Changeover Contact<br>AC Switching Capacity (Volts/Amps) 250V / 0.1A<br>DC Switching Capacity (Volts/Amps) 250V / 0.1A; 125V / 0.2A; 75V / 0.5A<br>Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals 60/75°C Max. 1.5mm [2 ] / 14AWG Solid/Flexible<br>Ordering Information Order from Catalog Numbers Above<br>**----- End of picture text -----**<br>
* Does not apply to 1200Vdc.
** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
## Typical Application Schematics
**==> picture [330 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
Common<br>Common<br> Equipment Equipment<br>Grounding Grounding<br>Conductor Conductor<br>Application A Application B<br>Two energized poles/modes One energized pole/mode<br>600, 1000 & 1200Vdc systems 600Vdc & 1000Vdc systems only<br>**----- End of picture text -----**<br>
**==> picture [141 x 196] intentionally omitted <==**
**----- Start of picture text -----**<br>
Common<br> Equipment<br>Grounding<br>Conductor<br>Application C<br>One energized pole/mode<br>600Vdc & 1000Vdc systems only<br>(Max. system discharge current<br>(8/20 μs) [Imax] 25kA)<br>**----- End of picture text -----**<br>
**Data Sheet: 2055**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**480**
**Overvoltage Devices** Bg
## **Photovoltaic DIN-Rail SPD**
## **BSPP_____YPV(R)**
## **Dimensions - mm**
**==> picture [257 x 158] intentionally omitted <==**
**----- Start of picture text -----**<br>
15.3 11.0<br>30.0<br>o9)<br>54.0 43.5 Shown with optional<br>7. 0<br>(3TE) 58.0 remote contact signaling<br>9.0<br>90.0 45.0<br>**----- End of picture text -----**<br>
**Module Circuit Diagrams**
**==> picture [169 x 46] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status<br>Contact<br>on@<br>Indication<br>Available<br>**----- End of picture text -----**<br>
**==> picture [519 x 123] intentionally omitted <==**
**----- Start of picture text -----**<br>
Description 1211<br>14<br>The Bussmann three-module photovoltaic Surge Protective MOV<br>Device (SPD) features easyID™ visual indication and optional<br>remote contact signaling (floating changeover contact) for use Thermal Disconnector<br>in PV systems.<br>These complete surge protective devices are suitable for all<br>PV systems in accordance with UL 1449 3 ei rd Edition, s<br>EN 50539-11 and IEC 60364-7-712. Includes a two year DC+/– DC–/+<br>limited warranty. BSPP_____YPV*<br>**----- End of picture text -----**<br>
These complete surge protective devices are suitable for all PV systems in accordance with UL 1449 ~~3~~ rd Edition, EN 50539-11 and IEC 60364-7-712. Includes a two year limited warranty.
Shown with optional remote contact signaling
These prewired solutions consist of a base and modules that feature a disconnection device in the event of an overload.
- For remote signaling contact, add “R” suffix to the part number. E.g., BSPP3600YPV _**R**_
In case of insulation faults in the generator circuit, a reliable and tested fault-resistant Y circuit prevents damage to the surge protective devices.
The green and red visual indicator flags show the module protective status (green = good, red = replace). Apart from this visual indication, the remote signaling option features a three terminal floating changeover contact that can be used as a make or break contact depending on the particular monitoring system design employed.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**481**
**Overvoltage Devices**
## **Wind IEC Class I DIN-Rail SPD**
**==> picture [523 x 347] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering Information<br>Nominal PV System Voltage 600Vdc 1000Vdc<br>Catalog Numbers: Without Remote Contact Signaling BSPP3600YPV BSPP31000YPV<br>(Base + Modules) With Remote Contact Signaling BSPP3600YPVR BSPP31000YPVR<br>Replacement Modules: BPP300SYPV BPP500SYPV<br>Specifications<br>Nominal PV System Voltage [UCPV] 600V 1000V<br>MCOV [UCPV] 600Vdc 1000Vdc<br>Max System Discharge Current (8/20µs) [Imax] 40kA 40kA<br>Voltage Protection Level [U P ] ≤2.5kV ≤4.0kV<br>Voltage Protection Level at 5kA [U P ] ≤2.0kV ≤3.5kV<br>Short-Circuit Withstand Capability [ISCPV] 125A<br>Technology Fault Resistant Y MOV Circuit<br>Operating Temperature Range [T U ] -40°C to +80°C<br>Nominal Discharge Current (8/20µs) (DC+ � DC-) (DC+/DC- � PE) [In] 20kA<br>Response Time [t A ] ≤25ns<br>Operating State/Fault Indication Green (good) / Red (replace)<br>Conductor Ratings and Cross-Sectional Area: Minimum 60/75°C 1.5mm [2 ] / 14AWG Solid/Flexible<br>Maximum 60/75°C 35mm [2 ] / 2AWG Stranded / 25mm [2 ] / 4AWG Flexible<br>Mounting 35mm DIN-Rail per EN 60715<br>Enclosure Material UL 94V0 Thermoplastic<br>Degree of Protection IP20<br>Capacity 3 Modules, DIN 43880<br>Standards Information: UL UL 1449 3 [rd] Edition (Type 2)<br>IEC EN 50539-11, IEC 61643-11 Type 2, IEC 61643-1 Class II<br>Product Warranty Two Years*<br>Remote Contact Signaling<br>Remote Contact Signaling Type Changeover Contact<br>AC Switching Capacity (Volts/Amps) 250V / 0.1A<br>DC Switching Capacity (Volts/Amps) 250V / 0.1A; 125V / 0.2A; 75V / 0.5A<br>Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals 60/75°C Max. 1.5mm [2 ] / 14AWG Solid/Flexible<br>Ordering Information Order from Catalog Numbers Above<br>**----- End of picture text -----**<br>
Typical Application Schematics
**==> picture [149 x 170] intentionally omitted <==**
Application A Two energized poles/modes 600 & 1000Vdc systems
**==> picture [156 x 168] intentionally omitted <==**
**==> picture [147 x 168] intentionally omitted <==**
Application B Application C One energized pole/mode One energized pole/mode 600Vdc & 1000Vdc systems only 600Vdc & 1000Vdc** systems
- See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
- ** BSPP31000YPV(R) 1000Vdc one energized pole/mode requires the following:
1. Use a suitable electrical insulator to keep a 10mm min. safety distance from the PV-SPD and other grounded parts in the housing.
2. No metal covers are in the area of the module release buttons as shown.
**Data Sheet: 10091**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**482**
**Overvoltage Devices**
## **Wind IEC Class I DIN-Rail SPD**
## **BSPS_ _ _ _WE**
## **Dimensions - mm**
Remote Signal Visual Status Indication Contact Available
Shown with optional remote contact signaling
## **Description**
The Bussmann IEC Class I 400 and 690V, one-pole lightning current arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling.
**Circuit Diagrams -** Shown with optional remote contact signaling
440V and 760V maximum continuous operating voltage arresters protect installations against surges and direct lightning strikes.
## **System & Application**
TNC 400V/690V: 3x BSPS1400WE(R) TNS 400/690V: 4x BSPS1400WE(R) IT 690V: 3x BSPS1690WER
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
**==> picture [88 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Creepage Discharge Spark Gap<br>Spark Gap Trigger<br>**----- End of picture text -----**<br>
**BSPS1400WE* BSPS1690WE**
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPS1400WER
**Data Sheet: 2091**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**483**
**Overvoltage Devices**
## **Wind IEC Class I DIN-Rail SPD**
**==> picture [523 x 549] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering Information<br>System Voltage/Poles 400V/1 690V/1<br>Max. Continuous Operating AC voltage (MCOV) [UC] 440V 760V<br>Catalog Numbers: Without Remote Signaling BSPS1400WE - -<br>With Remote Signaling BSPS1400WER BSPS1690WER<br>Specifications<br>Line System Type TNC, TNS, IT TNC, TNS, IT<br>Lightning impulse current (10/350 μs) [Iimp] 35kA 25kA<br>Specific Energy [W/R] 306.25kJ/ohms 156.25kJ/ohms<br>Nominal Discharge Current (8/20 μs) [In] 35kA 25kA<br>Voltage Protection Level [UP] _< 2.5kV _< 4kV<br>Follow Current Extinguishing Capability AC [Ifi] 50kArms 25kA rms<br>Follow Current Limitation / Selectivity no tripping of a 32 A gL/gG no tripping of a 32 A gL/gG<br>fuse up to 50 kArms (prosp.) fuse up to 25 kArms (prosp.)<br>Response Time [tA] _< 100 ns _< 100 ns<br>Max. Backup Fuse (L) up to IK = 25kArms (ta _< 5 s) - - 250A gL/gG<br>Max. Backup Fuse (L) up to IK > 25kArms - - 100A gL/gG<br>Max. Backup Fuse (L) up to IK = 50kArms (ta _< 0.2 s) 500A gL/gG - -<br>Max. Backup Fuse (L) up to IK = 50kArms (ta _< 5 s) 250A gL/gG - -<br>Max. Backup Fuse (L) for IK > 50kArms 160A gL/gG - -<br>Max. Backup Fuse (L-L ) 125A gL/gG 125A gL/gG<br>Short-Circuit Withstand Capability for<br>Max. Mains-Side Overcurrent Protection 50kArms 25kArms<br>Temporary Overvoltage (TOV) [UT] 690V / 5 sec. 1000V / 5 sec.<br>Cross-Sectional Area (L, L , ) [min.] - - 10mm [2] solid/flexible<br>Cross-Sectional Area (L, L , N/PEN) [min.] 10mm [2] solid/flexible - -<br>Cross-Sectional Area (L, N/PEN) [max.] 50mm [2] /1AWG stranded/35mm [2] /2AWG flexible - -<br>Cross-Sectional Area (L, ) [max.] - - 50mm [2] /1AWG stranded/35 mm [2] /2AWG flexible<br>Cross-Sectional Area (L ) [max.] 35mm [2] /2AWG stranded/25mm [2] /4AWG flexible 35mm [2] /2AWG stranded/25mm [2] /4AWG flexible<br>SPD According to EN 61643-11 Type 1<br>SPD According to IEC 61643-1 Class I<br>TOV Characteristics Withstand<br>Operating Temperature Range (parallel connection) [TUP] -40°C to +80°C<br>Operating Temperature Range (series connection) [TUS] -40°C to +60°C<br>Operating State/Fault Indication Green (good) / Red (replace)<br>Number of Ports 1<br>Mounting 35mm DIN rail per EN 60715<br>Enclosure Material Thermoplastic, UL 94V0<br>Place of Installation Indoor<br>Degree of Protection IP20<br>Capacity 2 Mods., DIN 43880<br>Product Warranty Five Years*<br>Remote Contact Signaling<br>Remote Contact Signaling Type Changeover Contact<br>AC Switching Capacity (Volts/Amps) 250V/0.5A<br>DC Switching Capacity (Volts/Amps) 250V/0.1A; 125V/0.2A; 75V/0.5A<br>Conductor Ratings and Cross-Sectional Area for Remote 60/75°C Max. 1.5mm [2] /<br>Contact Signal Terminals 14AWG Solid/Flexible<br>Ordering Information Order from Catalog Numbers Above<br>**----- End of picture text -----**<br>
**==> picture [253 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann NH DIN Size Back Up Fuses<br>Size NH Fuse Part Number<br>000 100NHG000B-690 (max L) up to IK > 25kArms<br>00 125NHG00B-690 (max L-L )<br>01 160NHG01B-690 (max L) for IK > 50kArms<br>02 250NHG02B-690 (max L) up to IK = 25kArms (ta _< 5 s)<br>02 250NHG02B-690 (max L) up to IK = 50kArms (ta _< 5 s)<br>3 500NHG3B-690 (max (L) up to IK = 50kArms (ta _< 0.2 s)<br>**----- End of picture text -----**<br>
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**Data Sheet: 2091**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**484**
**Overvoltage Devices**
## **Wind IEC Class II DIN-Rail SPD**
## **BSPM_ _ _ _WE, BSPS_ _ _ _WE**
**Module Circuit Diagrams -** Shown with optional remote contact signaling
**BSPM175WE* BSPG1230WE* BSPM11000WE* BSPM1400WE BSPM1690WE**
**==> picture [199 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>**----- End of picture text -----**<br>
MOV Thermal Disconnector Gas Discharge Tube (single)
## **Description**
The Bussmann IEC Class II 75, 230, 400, 690 and 1000V, one-pole, modular surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system on the 75 to 690V arresters fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
## **TN System Arresters (also 1-Phase TT systems)**
The features of these single-pole devices are for use as a single device or in combination with other devices.
## **TT System Arrester**
Provides a current arresting means between neutral conductor and protective conductor in TT systems, this device helps ensure fulfilling the requirements for protection of personnel and equipment in “3+1” and “1+1” circuits.
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPM175WER
**==> picture [188 x 263] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions - mm<br>a pg<br>i<br>N. 75 to 690V<br>Arresters<br>rer e<br>(1TE)<br>Shown with<br>optional remote<br>contact signaling<br>_ [ [S]<br>=<br>1000V Arrester<br>**----- End of picture text -----**<br>
**Data Sheet: 2092**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**485**
**Overvoltage Devices**
## **Wind IEC Class II DIN-Rail SPD**
|**Wind IEC Class II DIN-Rail SPD**|**Wind IEC Class II DIN-Rail SPD**|**Wind IEC Class II DIN-Rail SPD**|**Wind IEC Class II DIN-Rail SPD**|**Wind IEC Class II DIN-Rail SPD**|**Wind IEC Class II DIN-Rail SPD**|**Wind IEC Class II DIN-Rail SPD**|
|---|---|---|---|---|---|---|
|Ordering Information|||||||
|System Voltage/Poles||75V/1|230V/1|400V/1|690V/1|1000V/1|
|Max. Continuous operating AC voltage (MCOV) [UC]||75V|255V|440V|600V|1000V|
|Catalog Numbers:<br>Without Remote Signaling<br>(Base + Modules)<br>With Remote Signaling||BSPM175WE|BSPG1230WE|BSPM1400WE|BSPM1690WE|BSPM11000WE|
||Remote Signaling|BSPM175WER|BSPG1230WER|BSPM1400WER|BSPM1690WER|BSPM11000WER|
|Replacement Modules||BPM75WE|BPG255NPEWE*|BPM440WE|BPM750WE|N/A|
||Specifications||||||
|Line System Type||TN / TT|TT|TN / TT|TN / TT|TN / TT|
|Max. Continuous Operating DC Voltage [UC]||100V|- -|585|600V|1000V|
|Rated Varistor Voltage AC [Umov]||- -|- -|- -|750V|1000V|
|Nominal Discharge Current (8/20 μs) [In]||10kA|20kA|20kA|15kA|15kA|
|Max. Discharge Current (8/20 μs) [Imax]||40kA|40kA|40kA|25kA|30kA|
|Follow Current Extinguishing Capability [Ifi]||- -|100 Arms|- -|- -|- -|
|Lightning Impulse Current (10/350 μs) [Iimp]||- -|12kA|- -|- -|- -|
|Voltage Protection Level [UP]||_< 0.4kV|_< 1.5kV|_< 2.0kV|_< 3kV|_< 4.2kV|
|Voltage Protection Level at 5kA [UP]||_< 0.35kV|- -|_< 1.7kV|_< 2.5kV|_< 3.5kV|
|Response Time [tA]||_< 25 ns|_< 100 ns|_< 25 ns|_< 25 ns|_< 25 ns|
|Max. Mains-side Overcurrent Protection||125A gL/gG|- -|125A gL/gG|100A gL/gG|100A aM**|
|Short-Circuit Withstand Capability for<br>Max. Mains-side Overcurrent Protection||50kArms|- -|25kArms|25kArms|25kArms|
|Temporary Overvoltage (TOV) [UT]||90V / 5 sec.|1200V / 200ms|580V / 5 sec.|900V / 5 sec.|1000V / 5 sec.|
|Standards Information||KEMA, CSA|KEMA|KEMA, CSA|KEMA, CSA|- -|
|Capacity||1 Mod., DIN 43880|1 Mod., DIN 43880|1 Mod., DIN 43880|1 Mod., DIN 43880|2 Mod., DIN 43880|
|SPD According to EN 61643-11||Type 2|||||
|SPD According to IEC 61643-1||Class II|||||
|TOV Characteristics||Withstand|||||
|Operating Temperature Range [TU]||-40°C to +80°C|||||
|Operating State/Fault Indication||Green (good) / Red (replace)|||||
|Number of Ports||1|||||
|Cross-Sectional Area (min.)||1.5mm2/14AWG solid/flexible|||||
|Cross-Sectional Area (max.)||35mm2/2AWG stranded-25mm2/4AWG flexible|||||
|Mounting||35mm DIN rail per EN 60715|||||
|Enclosure Material||Thermoplastic, UL 94V0|||||
|Location Category||Indoor|||||
|Degree of Protection||IP20|||||
|Product Warranty||Five Years***|||||
|Remote Contact Signaling|||||||
|Remote Contact Signaling Type||Changeover Contact|||||
|AC Switching Capacity (Volts/Amps)||250V/0.5A|||||
|DC Switching Capacity (Volts/Amps)||250V/0.1A; 125V/0.2A; 75V/0.5A|||||
|Conductor Ratings and Cross-Sectional Area for<br>Remote Contact Signal Terminals||60/75°C Max. 1.5mm2/14AWG Solid/Flexible|||||
|Ordering Information||Order from Catalog Numbers Above|||||
- N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
- ** 125A gL/gG @ 690Vac.
- *** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [185 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann Back Up Fuses<br>DIN Fuse Size NH Fuse Part Number<br>00 100NHG00B-690<br>00 125NHG00B-690<br>**----- End of picture text -----**<br>
## **Data Sheet: 2092**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**486**
**Overvoltage Devices**
## **Wind IEC Class II DIN-Rail SPD**
## **BSPM_ _ _ _WE, BSPH_ _ _ _WE**
**==> picture [80 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions - mm<br>**----- End of picture text -----**<br>
**==> picture [198 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication easylD" (“en ) Contact Available<br>**----- End of picture text -----**<br>
## **Description**
Shown with optional remote contact signaling
**Module Circuit Diagrams -** Shown with optional remote contact signaling
The Bussmann IEC Class II 230V, two-pole, modular surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
## **TN System Arrester**
The features of these two-pole device are for use as a single device.
## **TT System Arrester**
For use as a single device in a 1-phase TT system.
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
**==> picture [220 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
BSPM2230WE* BSPH2230WE*<br>MOV Gas Discharge Tube (single)<br>¢<br>Thermal Disconnector<br>**----- End of picture text -----**<br>
*For remote signaling contact, add “R” suffix to the part number, E.g., BSPM2230WER
**Data Sheet: 2093**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**487**
**Overvoltage Devices**
## **Wind IEC Class II DIN-Rail SPD**
|Ordering Information|Ordering Information|Ordering Information|Ordering Information|
|---|---|---|---|
|System Voltage/Poles||230V/2|230V/2|
|Max. Continuous operating AC voltage (MCOV) [UC]||275V|275 / 255V|
|Catalog Numbers:<br>(Base + Modules)|Without Remote Signaling|BSPM2230WE|BSPH2230WE|
||With Remote Signaling|BSPM2230WER|BSPH2230WER|
|Replacement Modules|MOV|BPM275WE|BPM275WE|
||Spark Gap|- -|BPSNPEWE*|
||Specifications|||
|Line System Type||TN|TT|
|Max. Continuous Operating AC Voltage [L-N] [UC]||- -|275V|
|Max. Continuous Operating AC Voltage [N-PE] [UC]||- -|255V|
|Nominal Discharge Current (8/20 μs)[In]||20kA|20kA|
|Max. Discharge Current (8/20 μs)[Imax]||40kA|40kA|
|Lightning Impulse Current (10/350 μs) [N-PE] [Iimp]||- -|12kA|
|Voltage Protection Level [UP]||_< 1.25kV|- -|
|Voltage Protection Level at 5kA [UP]||_< 1kV|- -|
|Voltage Protection Level [L-N] [UP]||- -|_< 1.25kV|
|Voltage Protection Level [L-N] at 5kA [UP]||- -|_< 1kV|
|Voltage Protection Level [N-PE] [UP]||- -|_< 1.5kV|
|Follow Current Extinguishing Capability [N-PE] [Ifi]||- -|100Arms|
|Response Time [L-N] [tA]||- -|_< 25 ns|
|Response Time [N-PE] [tA]||- -|_< 100 ns|
|Response Time [tA]||_< 25 ns|- -|
|Max. Mains-side Overcurrent Protection||125A gL/gG|125A gL/gG|
|Short-circuit Withstand Capability for Max. Mains-side Overcurrent Protection||50kArms|50kArms|
|Temporary Overvoltage (TOV) [UT]||335 V / 5 sec.|- -|
|Temporary Overvoltage (TOV) [L-N] [UT]||- -|335V / 5 sec.|
|Temporary Overvoltage (TOV) [N-PE] [UT]||- -|1200V / 200 ms|
|SPD According to EN 61643-11||Type 2||
|SPD According to IEC 61643-1||Class II||
|TOV Characteristics||Withstand||
|Operating Temperature Rrange [TU]||-40°C to +80°C||
|Operating State/Fault Indication||Green (good) / Red (replace)||
|Number of Ports||1||
|Cross-sectional Area (min.)||1.5mm2/14AWG solid/flexible||
|Cross-sectional Area (max.)||35mm2/2AWG stranded-25mm2/4AWG flexible||
|Mounting||35mm DIN rail per EN 60715||
|Enclosure Material||Thermoplastic, UL 94V0||
|Location Category||Indoor||
|Degree of Protection||IP20||
|Capacity||2 Mods., DIN 43880||
|Standards Information||KEMA||
|Product Warranty||Five Years**||
|Remote Contact Signaling||||
|Remote Contact Signaling Type||Changeover Contact||
|AC Switching Capacity (Volts/Amps)||250V/0.5A||
|DC Switching Capacity (Volts/Amps)||250V/0.1A; 125V/0.2A; 75V/0.5A||
|Conductor Ratings and Cross-Sectional Area for<br>Remote Contact Signal Terminals||60/75°C Max. 1.5mm2/<br>14AWG Solid/Flexible||
|Ordering Information||Order from Catalog Numbers Above||
* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
- ** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [185 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann Back Up Fuse<br>DIN Fuse Size NH Fuse Part Number<br>00 125NHG00B<br>**----- End of picture text -----**<br>
**Data Sheet: 2093**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**488**
**Overvoltage Devices**
## **Wind IEC Class II DIN-Rail SPD**
## **BSPM_ _ _ _WE**
## **Dimensions - mm**
**==> picture [198 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>cand" (=)<br>**----- End of picture text -----**<br>
Shown with optional remote contact signaling
**Module Circuit Diagrams -** Shown with optional remote contact signaling
## **Specifications Description**
The Bussmann IEC Class II 230, 400 and 690V three-pole, modular surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
## **TNC System Arresters**
The features of these three-pole devices are for use as a single device.
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
## **BSPM3230WE BSPM3400WE BSPM3690WE**
MOV Thermal Disconnector
**Data Sheet: 2094**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**489**
**Overvoltage Devices**
## **Wind IEC Class II DIN-Rail SPD**
**==> picture [522 x 440] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering Information<br>System Voltage/Poles 230V/3 400V/3 690V/3<br>Max. Continuous operating AC voltage (MCOV) [UC] 275V 440V 600V<br>Catalog Numbers: Without Remote Signaling BSPM3230WE BSPM3400WE BSPM3690WE<br>(Base + Modules) With Remote Signaling BSPM3230WER BSPM3400WER BSPM3690WER<br>Replacement Modules BPM275WE BPM440WE BPM750WE<br>Specifications<br>Line System Type TNC TNC TNC<br>Nominal AC Voltage [UN] 230/400V 400/690V 600V<br>Rated Varistor Voltage [Umov] 275V 440V 750V<br>Nominal Discharge Current (8/20 μs) [In] 20kA 20kA 15kA<br>Max. Discharge Current (8/20 μs) [Imax] 40kA 40kA 25kA<br>Voltage Protection Level [UP] _<1.25kV _< 2kV _<3kV<br>Voltage Protection Level at 5kA [UP] _<1kV _< 1.7kV _<2.5kV<br>Response Time [tA] _<25 ns _< 25 ns _<25 ns<br>Max. Mains-side Overcurrent Protection 125A gL/gG 125A gL/gG 100A gL/gG<br>Short-circuit Withstand Capability for Max. Mains-side Overcurrent Protection 50kArms 25kArms 25kArms<br>Temporary Overvoltage (TOV) [UT] 335V / 5 sec. 580V / 5 sec. 900V / 5 sec.<br>SPD According to EN 61643-11 Type 2<br>SPD According to IEC 61643-1 Class II<br>TOV Characteristics Withstand<br>Operating Temperature Range [TU] -40°C to +80°C<br>Operating State/Fault Indication Green (good) / Red (replace)<br>Number of Ports 1<br>Cross-Sectional Area (min.) 1.5mm [2] /14AWG solid/flexible<br>Cross-Sectional Area (max.) 35mm [2] /2AWG stranded-25mm [2] /4AWG flexible<br>Mounting 35mm DIN rail per EN 60715<br>Enclosure Material Thermoplastic, UL 94V0<br>Location Category Indoor<br>Degree of Protection IP20<br>Capacity 3 Mods., DIN 43880<br>Standards Information KEMA<br>Product Warranty Five Years*<br>Remote Contact Signaling<br>Remote Contact Signaling Type Changeover Contact<br>AC Switching Capacity (Volts/Amps) 250V/0.5A<br>DC Switching Capacity (Volts/Amps) 250V/0.1A; 125V/0.2A; 75V/0.5A<br>Conductor Ratings and Cross-Sectional Area for<br>60/75°C Max. 1.5mm [2] /14AWG Solid/Flexible<br>Remote Contact Signal Terminals<br>Ordering Information Order from Catalog Numbers Above<br>**----- End of picture text -----**<br>
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**==> picture [185 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann Back Up Fuse<br>DIN Fuse Size NH Fuse Part Number<br>100NHG00B-690<br>00<br>125NHG00B-690<br>**----- End of picture text -----**<br>
**Data Sheet: 2094**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**490**
**Overvoltage Devices**
## **Wind IEC Class II DIN-Rail SPD**
## **BSPM_ _ _ _WE, BSPH_ _ _ _WE**
## **Dimensions - mm**
**==> picture [198 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
Remote Signal<br>Visual Status Indication Contact Available<br>**----- End of picture text -----**<br>
Shown with optional remote contact signaling
## **Specifications Description**
The Bussmann IEC Class II 230/400V, four-pole, modular surge arresters feature local, _easy_ ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
**Circuit Diagrams -** Shown with optional remote contact signaling
These 230V models are offered with MCOV ratings of 275V.
## **TNS System Arrester**
The features of these four-pole devices are for use in TNS 230/400V systems (“4-0” circuit) against surges.
## **TT System Arrester**
The features of these four-pole devices are for use in TT and TN-S 230/400V systems (“3+1” circuit) against surges.
## **Remote Signaling Contact**
The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept.
**==> picture [212 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
MOV<br>+ PE al<br>BSPM4230WE<br>Thermal Disconnector<br>Gas Discharge Tube<br>(single)<br>[@]<br>**----- End of picture text -----**<br>
## **BSPH4230WE**
**Data Sheet: 2095**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**491**
**Overvoltage Devices**
## **Wind IEC Class II DIN-Rail SPD**
**==> picture [524 x 549] intentionally omitted <==**
**----- Start of picture text -----**<br>
ORDERING INFORMATION<br>System Voltage/Poles 230/400V/4 230/400V/4<br>Max. continuous operating AC voltage (MCOV) [UC] 275V - -<br>Max. continuous operating AC voltage (MCOV) [L-N] [UC] - - 275V<br>Max. continuous operating AC voltage [N-PE] [UC] - - 255V<br>Catalog Numbers: Without Remote Signaling BSPM4230WE BSPH4230WE<br>With Remote Signaling BSPM4230WER BSPH4230WER<br>Replacement Modules: MOV technology BPM275WE BPM275WE<br>Spark Gap technology - - BPSNPEWE*<br>SPECIFICATIONS<br>Line System Type TNS TT / TNS<br>Nominal AC voltage [UN] 230/400V 230/400V<br>Lightning impulse current (10/350 μs) [N-PE] [Iimp] - - 12kA<br>Voltage protection level [UP] <_ 1.25kV - -<br>Voltage protection level at 5kA [UP] <_ 1kV - -<br>Voltage protection level [L-N] [UP] - - <_ 1.25kV<br>Voltage protection level [L-N] at 5kA [UP] - - <_ 1kV<br>Voltage protection level [N-PE] [UP] - - <_ 1.5kV<br>Follow current extinguishing capability [N-PE] [Ifi] - - 100Arms<br>Response time [tA] <_ 25 ns - -<br>Response time [L-N] [tA] - - <_ 25 ns<br>Response time [N-PE] [tA] - - <_ 100 ns<br>Temporary overvoltage (TOV) [UT] 335V / 5 sec. - -<br>Temporary overvoltage (TOV) [L-N] [UT] - - 335V / 5 sec.<br>Temporary overvoltage (TOV) [N-PE] [UT] - - 1200V / 200 ms<br>SPD according to EN 61643-11 Type 2<br>SPD according to IEC 61643-1 Class II<br>Nominal discharge current (8/20 μs) [In] 20kA<br>Max. discharge current (8/20 μs) [Imax] 40kA<br>Max. mains-side overcurrent protection 125A gL/gG<br>Short-circuit withstand capability for max. mains-side overcurrent protection 50kA rms<br>TOV characteristics withstand<br>Operating temperature range [TU] -40°C to +80°C<br>Operating state/fault indication green (good)/red (replace)<br>Number of ports 1<br>Cross-sectional area (min.) 1.5mm [2] /14AWG solid/flexible<br>Cross-sectional area (max.) 35mm [2] /2AWG stranded-25mm [2] /4AWG flexible<br>Mounting 35mm DIN rail per EN 60715<br>Enclosure material Thermoplastic, UL 94V0<br>Location category Indoor<br>Degree of protection IP20<br>Capacity 4 Mods., DIN 43880<br>Standards Information KEMA<br>Product Warranty Five Years**<br>REMOTE CONTACT SIGNALING<br>Remote Contact Signaling Type Changeover Contact<br>AC Switching Capacity (Volts/Amps) 250V/0.1A<br>DC Switching Capacity (Volts/Amps) 250V/0.1A; 125V/0.2A; 75V/0.5A<br>Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals 60/75°C Max. 1.5mm [2] /14AWG Solid/Flexible<br>Ordering Information Order from Catalog Numbers Above<br>**----- End of picture text -----**<br>
**==> picture [186 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Bussmann Back Up Fuse<br>DIN Fuse Size NH Fuse Part Number<br>00 125NHG00B<br>**----- End of picture text -----**<br>
* N-PE Surge arrester module for location between neutral conductor and protective conductor in TT systems. ** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
**Data Sheet: 2095**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**492**
**Overvoltage Devices** Ban
## Surge Protection Made Simple™ for Coaxial Data Cables
## UL Listed 497B DIN-Rail Mount Surge Protective Device for BNC Connector Cable Systems
## **Description**
The Bussmann BSPD5BNCDD and BSPD5BNCDI two-stage DIN-Rail mounted surge arresters are for protecting coaxial cable-connected systems (such as video and camera systems) from potential damage. The BSPD5BNCDD features direct (VCD) shield connection while the BSPD5BNCDI features indirect shield connection (VCID) to prevent leakage pickups.
**BSPD5BNCDD BSPD5BNCDI**
The BSPD5BNCDD and BSPD5BNCDI shielded surge arresters are mounted on the supplied bracket with cable lug or mounted on a rack mounted DIN-Rail with suitable grounding. BNC connector terminated data or video signal cables are plugged into surge arrester with the equipment plugged into the protected side.
Common applications include protecting outdoor video surveillance systems or video control centers or coaxial data lines. For BSPD5BNCDI, the cable shield is indirectly grounded via a gas discharge tube to avoid being influenced by leakage pickups.
- UL 497B Listed
- Plug-in surge protective device for easy retrofitting
- The space-saving surge arrester with BNC socket is mounted on supplied rail terminal lug or standard 35mm DIN-Rail
- Integrated direct or indirect shield grounding avoids leakage pickups
- Easily adaptable due to BNC sockets
## **Dimensions-mm**
**==> picture [178 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
| ft<br>ee<br>7<br>fe) y |<br> 19.00 12.70<br> 100.08<br> 35.50<br>**----- End of picture text -----**<br>
## **DIN-Rail Mount SPD for BNC Coax**
## **Circuit Diagrams**
**==> picture [80 x 45] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protected<br>side<br>x Direct Shield<br>BSPD5BNCDD<br>**----- End of picture text -----**<br>
**==> picture [70 x 45] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protected<br>side<br>Indirect Shield<br>BSPD5BNCDI<br>**----- End of picture text -----**<br>
**==> picture [188 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
Gas Discharge Tube Bi-Polar Suppressor Diode<br>Pluggable Earthing Contact Decoupling Resistor<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**493**
**Overvoltage Devices**
|Technical Data<br>~~Ce~~<br>~~ee~~|Technical Data<br>~~Ce~~<br>~~ee~~|Technical Data<br>~~Ce~~<br>~~ee~~|
|---|---|---|
|Catalog Number<br>~~es~~|BSPD5BNCDD<br>~~es~~<br>~~ee~~|BSPD5BNCDI<br>~~es~~|
|Return loss at 300MHz<br>~~es~~|≥8dB<br>~~es~~<br>~~ee~~<br>~~ee~~|≥10dB<br>~~es~~|
|Capacitance shield-PG (C)<br>~~es~~|—<br>~~ee~~<br>~~es~~<br>~~ee~~|≤20pF<br>~~es~~|
|Voltage protection level shield-PG for I~~n ~~C2 (Up)<br>~~es~~|—<br>~~es~~<br>~~ee~~|≤650V<br>~~es~~|
|~~n ~~<br>Voltage protection level shield-PG at 1kV/μs C3 (Up)<br>~~es~~<br>~~es~~|—<br>~~es~~<br>~~ee~~<br>~~es~~|≤600V<br>~~es~~<br>~~es~~|
|Nominal voltage (UN)<br>~~es~~|5V<br>~~es~~||
|Max. continuous operating DC voltage (UC)<br>~~ee~~|6.4V<br>~~ee~~||
|Nominal current (IL)<br>~~ee~~|0.1A<br>~~ee~~||
|C2 Nominal discharge current (8/20μs) shield-PG (In)<br>~~es~~|10kA<br>~~es~~||
|C2 Nominal discharge current (8/20μs) line-shield (In)<br>~~es~~|5kA<br>~~es~~||
|Voltage protection level line-shield for In C2 (Up)<br>~~ee~~|≤35V<br>~~ee~~||
|Voltage protection level line-shield at 1kV/μs C3 (Up)<br>~~ee~~|≤13V<br>~~ee~~||
|Frequency range<br>~~ee~~<br>~~pe~~|0-300MHz<br>~~ee~~<br>~~pe~~||
|Insertion loss at 160MHz<br>~~pe~~|≤0.4dB<br>~~pe~~||
|Insertion loss at 300MHz<br>~~pe~~<br>~~es~~|≤3dB<br>~~pe~~<br>~~es~~||
|Return loss at 130MHz<br>~~es~~|≥20dB<br>~~es~~||
|Impedance (Z)<br>~~es~~|50Ω<br>~~es~~||
|Series impedance per line<br>~~es~~|4.7Ω<br>~~es~~||
|Capacitance line-shield (C)<br>~~es~~|≤25pF<br>~~es~~||
|Operating temperature range<br>~~es~~|-40°C to +80°C<br>~~es~~||
|Degree of protection<br>~~eT~~|IP10<br>~~eT~~||
|For mounting on<br>~~eT~~|35mm DIN-Rails per EN 60715<br>~~eT~~||
|Connection (input / output)<br>~~eT~~<br>~~es~~|BNC Socket (female) / BNC Socket (female)<br>~~eT~~<br>~~es~~||
|Grounding<br>~~es~~|Via 35mm DIN-Rail per EN 60715<br>~~es~~||
|Enclosure material<br>~~ee~~|Zinc die casting<br>~~ee~~||
|Color<br>~~ee~~|Bare surface<br>~~ee~~||
|Test standards<br>~~es~~|IEC 61643-21 / EN 61643-21<br>~~es~~||
|Agency Information<br>~~es~~|UL 497B<br>~~es~~||
|Warranty<br>~~a~~|5 Years*<br>~~a~~||
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.
## **Direct vs. Indirect Shielding - Application Example**
## **DIN-Rail BNC SPD Applications**
|Part Numbers|BSPD5BNCDD|BSPD5BNCDI|
|---|---|---|
|Bus Systems and Measuring, and Control Technology|||
|Control Net|X|X|
|Melsec Net 2|X|X|
|N1 LAN|X|X|
|Data Networks|||
|Arcnet|X|X|
|Video Systems|||
|Video (coax)|Video Systems<br>X|X|
Apply the BSPD5BNCDD (direct shield) at the equipment location and apply the BSPD5BNCDI (indirect shield) near exterior protected equipment. The indirect shield grounding at the exterior device will help avoid picking up leakage currents that can degrade signal quality while providing surge protection when needed. See illustration below for installation locations.
**==> picture [200 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
protective angle<br>IEC 62305-4<br>Video<br>system<br>LPZ 2 protectedside coaxial LPZ 1 protectedside LPZ 0B<br>BSPD5BNCDD BSPD5BNCDI<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**494**
**Overvoltage Devices** Ba
## Surge Protection Made Simple™ for Coaxial Data Cables
## UL Listed 497B In-line Surge Protective Device for BNC Connector Cable Systems
## **Description**
The Bussmann BSPD5BNCSI two-stage in-line surge arrester is for protecting coaxial cable-connected systems (such as video and camera systems) from potential damage.
**==> picture [65 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
BSPD5BNCSI<br>**----- End of picture text -----**<br>
The BSPD5BNCSI shielded surge arrester is plugged into coaxial terminal equipment or connections. Common applications include protecting outdoor video surveillance systems or video control centers. The cable shield is indirectly grounded via a gas discharge tube to avoid being influenced by leakage pickups. The arrester input is used as a socket and the protected output as a plug.
- UL 497B Listed
- Plug-in surge protective device for easy retrofitting
- Directly plugs into terminal equipment with BNC coaxial connections
- Integrated indirect shield grounding avoids leakage pickups
## **Dimensions-mm**
**==> picture [176 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
300.00 APPROX<br>24.00<br>@ ) -<br> 74.00<br>**----- End of picture text -----**<br>
**==> picture [277 x 281] intentionally omitted <==**
**----- Start of picture text -----**<br>
In-line SPD for BNC Coax<br>Circuit Diagram<br>|io |= protected<br>= [<br>| |<br>_ + —-<br>a<br>Gas Discharge Tube Bi-Polar Suppressor Diode<br>b i<br>Decoupling Resistor Capacitor<br>Devices<br>Surge Protection<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**495**
**Overvoltage Devices**
|TECHNICAL DATA|TECHNICAL DATA|
|---|---|
|CatalogNumber|BSPD5BNCSI|
|Nominal voltage(UN)|5V|
|Max. continuous operatingDC voltage(UC)|8V|
|C2 Nominal discharge current(8/20μs) per line(In)|2.5kA|
|C2 Nominal discharge current(8/20μs)shield-PG(In)|10kA|
|Voltageprotection level line-shield for In C2(Up)|≤25V|
|p<br>Voltageprotection level line-shield at 1kV/μs C3(Up)|≤15V|
|p<br>Voltageprotection level shield-PG at 1kV/μs C3(Up)|≤600V|
|p<br>Insertion loss at 265MHz|≤3dB|
|Return loss at 40MHz|≥20dB|
|Impedance(Z)|75Ω|
|Series impedanceper line|10Ω|
|Capacitance line-shield(C)|≤50pF|
|Operatingtemperature range|-40°C to +80°C|
|Connection(input / output)|BNC Socket(female)/ BNC Plug (male)|
|Grounding|Via outgoingearth conductor 18AWG(0.75mm2)|
|Shieldgrounding|Indirectlyvia an integrated sparkgapelement|
|Test standards|IEC 61643-21 / EN 61643-21|
|Agencyinformation|UL 497B|
|Warranty|5 Years*|
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.
**In-line BNC SPD Applications**
Part Number BSPD5BNCSI Bus Systems and Measuring & Control Technology Control Net X Melsec Net 2 X Data Networks Arcnet X Video Systems ~~==~~ Video (coax) X =.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**496**
**Overvoltage Devices** ar
## Surge Protection Made Simple™ for Ethernet Data Cables
## UL Listed 497B Universal DIN-Rail Mount Surge Protective Device for RJ45/Ethernet Cable Systems
## **Description**
The Bussmann DIN-Rail mount BSPD48RJ45 Surge Protective Device (SPD) for Ethernet cable systems with RJ connectors is easy to install in new, or retrofitting into existing, installations.
## **BSPD48RJ45**
The BSPD48RJ45 is installed between the patch panel and the active component (a switch for example). The snap-in mechanism of the supporting foot allows the SPD to be safely grounded via the DIN-Rail. For single applications, the BSPD48RJ45 comes with a supplied mounting bracket with cable lug.
Fulfilling the requirements of Category 6, the BSPD48RJ45 can be universally used for all data services up to nominal voltages of 48V. It is well suited for existing services such as Gigabit Ethernet, ATM, ISDN, Voice over IP and Power over Ethernet (PoE+ acc. to IEEE 802.3at up to 57V) and similar applications in structured cabling systems according to Class E up to 250MHz. Protection of all pairs by means of powerful gas discharge tubes and one adapter filter matrix per pair.
- UL 497B Listed
- Easy to install or retrofit for protection of all lines
- CAT 6 according to ISO/IEC 11801
## **DIN-Rail Mount SPD for RJ45 / Ethernet Connection**
- CAT 6 in the channel (Class E)
- Power over Ethernet (PoE+ according to IEEE 802.3at)
## **Dimensions -mm**
**==> picture [443 x 234] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuit Diagram<br> 19.00<br> 11.72<br>gi | |<br> 76.91<br>Balanced Gas<br>Bipolar Suppressor Diode<br>Discharge Tube<br>Pluggable Earthing Contact Inductor<br> 36.15<br>L es] 4 $<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**497**
**Overvoltage Devices**
|TECHNICAL DATA<br>~~CO~~~~**a**~~|TECHNICAL DATA<br>~~CO~~~~**a**~~|
|---|---|
|CatalogNumber<br>~~CO~~~~**a**~~|BSPD48RJ45|
|Nominal voltage (UN)<br>~~**a**~~<br>~~a~~|48V<br>|
|Max.continuous operatingDCvoltage (UC)<br>~~a~~|48V<br>|
|Max.continuous operatingACvoltage (UC)<br>~~are~~<br>~~**a**~~|34V<br>~~re~~|
|Max.continuousDCvoltage pair-pair(PoE) (UC)<br>~~**a**~~|57V|
|Nominalcurrent (IL)<br>~~**a**~~<br>~~**a**~~|1A|
|C2 Nominaldischarge current (8/20μs)line-line (In)<br>~~**a**~~|150A|
|C2 Nominaldischarge current (8/20μs)line-PG (In)<br>~~**a**~~<br>~~a~~|2.5kA<br>|
|C2 Total nominaldischarge current (8/20μs)line-PG (In)<br>~~a~~|10kA<br>|
|C2 nominaldischarge current (8/20μs) pair-pair(PoE) (In)<br>~~are~~<br>~~**a**~~|150A<br>~~re~~|
|Voltage protection level line-linefor In C2(UP)<br>~~**a**~~|≤190V|
|Voltage protection level line-PGfor In C2(UP)<br>~~**a**~~<br>~~**a**~~|≤600V|
|Voltage protection level line-linefor In C2(PoE) (UP)<br>~~**a**~~|≤600V|
|Voltage protection level line-line at1kV/μs C3 (UP)<br>~~**a**~~<br>~~a~~|≤180V<br>|
|Voltage protection level line-PG at1kV/μs C3 (UP)<br>~~a~~|≤500V<br>|
|Voltage protection levelpair-pairat1kV/μs C3 (PoE) (UP)<br>~~are~~<br>~~**a**~~|≤600V<br>~~re~~|
|Insertion loss at250MHz<br>~~**a**~~|≤3dB|
|Capacitanceline-line (C)<br>~~**a**~~<br>~~**a**~~|≤30pF|
|Capacitanceline-PG (C)<br>~~**a**~~|≤25pF|
|Operating temperaturerange<br>~~**a**~~<br>~~a~~|-40°C to+80°C<br>|
|Degree ofprotection<br>~~a~~|IP10<br>|
|For mounting on<br>~~are~~<br>~~**a**~~|35mm DIN-Rails per EN60715<br>~~re~~|
|Connection(input / output)<br>~~**a**~~|RJ45 socket /RJ45 socket|
|Pinning<br>~~**a**~~<br>~~**a**~~|1/2, 3 / 6,4/ 5,7/ 8|
|Grounding<br>~~**a**~~|Via 35mm DIN-Rails per EN60715|
|Enclosurematerial<br>~~**a**~~<br>~~a~~|Zinc die casting<br>|
|Color<br>~~a~~|Bare surface<br>|
|Test standards<br>~~are~~<br>~~a~~|IEC 61643-21/EN61643-21<br>~~re~~|
|Agencyinformation<br>~~a~~|UL 497B|
|Warranty<br>~~a~~|5 Years*|
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.
## **DIN-Rail RJ45 SPDs Applications**
|Part Number|BSPD48RJ45|
|---|---|
|Bus systems and Measuring, and Control Technology||
|Industrial Ethernet|X|
|Data Networks||
|ATM|X|
|Ethernet 10/100/1000|X|
|FDDI, CDDI|X|
|Industrial Ethernet|X|
|Power over Ethernet (PoE)|X|
|Token Ring|X|
|VG Any LAN|X|
|Video Systems||
|Video (2 wire)|X|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**498**
**Overvoltage Devices** gi
**Surge Protection Made Simple™ for Twisted Pair Data Cables** UL Listed 497B DIN-Rail Mount Universal Surge Protective Device for Measuring and Control Circuits, and Bus Systems
**==> picture [77 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
C US<br>©E. &<br>**----- End of picture text -----**<br>
## **Description**
The Bussmann universal four-pole, DIN-Rail mounted surge arresters provide effective protection with minimum space requirements and are designed for stringent requirements on the availability of measuring and control circuits, and bus systems.
To ensure safe operation, the arresters provide protection against vibration and shock up to a 30-fold acceleration of gravity. The function-optimized design of the devices allows quick and easy removal of protection modules via “make-before-break” terminals that assure continuity of data signals in the protected and unprotected state.
**BSPD5DING BSPD12DING BSPD24DING BSPD48DING BSPD5DINLHF BSPD24DINLHF**
**BSPD0180DINL**
_For IEC Applications_ - Instruction for Surge Protective Device Use In Zone 2 Explosive Atmospheres per ATEX.
1. When installed in potentially explosive atmospheres, the Data Signal DIN Series shall be installed into an enclosure which meets the requirements of a recognized type of protection, in accordance with EN 60079-0.
2. The Data Signal DIN Series as transient suppressor. This approval applies to the following equipment types:
- BSPD5DING • BSPD12DING • BSPD24DING
- BSPD48DING • BSPD5DINLHF • BSPD24DINLHF
Ambient and Temperature Class
## **Four-Pole DIN-Rail Mount Universal SPD for Data Signal Applications**
## **Circuit Diagrams**
- -40°C to +80°C, T4:
- DEKRA 12ATEX0254 X: II 3 G Ex nA IIC T4 Gc
**==> picture [490 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 1´<br>• Standards used for:<br>ATEX: EN60079-0: 2009, EN 60079-15: 2005 5 2 of | 2´<br>UL 497B Listed<br>Function-optimized design for safe use and easy installation<br>Four-pole and base mounts on grounded 35mm DIN-Rail 3 3´<br>Module removal without signal interruption via “make-before- 4 4´<br>1 1´<br>2 2´<br>3 3‘<br>4 4‘<br>Protected Protected<br>**----- End of picture text -----**<br>
- UL 497B Listed
- Function-optimized design for safe use and easy installation
- Four-pole and base mounts on grounded 35mm DIN-Rail
- Module removal without signal interruption via “make-beforebreak” circuitry
- 0-180V BSPD0180DINL automatically adjusts to system operating voltage and can protect data circuits of different voltages up to 100mA load current.
**BSPD5DING BSPD5DINLHF BSPD12DING BSPD24DINLHF BSPD24DING BSPD48DING**
**==> picture [250 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions-mm 71.99 50.49<br> 35.51<br>12.00 1 6.09<br>_ [wa<br>90.00 45.00<br>|<br>____<br>6.70<br>3.97 49.99<br>**----- End of picture text -----**<br>
**==> picture [240 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
BSPD48DING 1 1‘<br>Balanced Gas i U>UN<br>Discharge Tube 2 2‘<br>i<br>3 3‘<br>* Decoupling Resistor (a i e! U>UN<br>4 4‘<br>i<br>Bipolar Suppressor Diode ee<br>BSPD0180DINL<br>Transient Blocking Unit<br>By<br>Thyristor U>UN Surge Detection<br>i<br>Protected<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**499**
**Overvoltage Devices**
|TECHNICALDATA|TECHNICALDATA|TECHNICALDATA|TECHNICALDATA|TECHNICALDATA|TECHNICALDATA|TECHNICALDATA|TECHNICALDATA|
|---|---|---|---|---|---|---|---|
|Catalog number—Prefix: BSPD…<br>~~OO~~|…5DING<br>~~OO~~|…12DING<br>~~OO~~|…24DING<br>~~OO~~|…48DING<br>~~OO~~|…5DINLHF<br>~~OO~~|…24DINLHF<br>~~OO~~|…0180DINL<br>~~OO~~|
|Nominal voltage (UN)<br>~~OO~~<br>~~GO~~|5V<br>~~OO~~<br>~~GO~~|12V<br>~~OO~~<br>~~GO~~|24V<br>~~OO~~<br>~~GO~~|48V<br>~~OO~~<br>~~GO~~|5V<br>~~OO~~<br>~~GO~~|24V<br>~~OO~~<br>~~GO~~|0-180V<br>~~OO~~<br>~~GO~~|
|Nominal current at 45°C (IL)<br>~~GO~~<br>~~Po~~|1.0A<br>~~GO~~<br>~~pp~~|0.75A<br>~~GO~~<br>~~pp~~|0.75A<br>~~GO~~<br>~~pp~~|0.75A<br>~~GO~~<br>~~pp~~|1.0A<br>~~GO~~<br>~~pp~~|1.0A<br>~~GO~~<br>~~pp~~|≤0.1A@80°C<br>~~GO~~<br>~~pp~~|
|VPL line-line for IimpD1 (Up)<br>~~Po~~|≤29V<br>~~pp~~|≤50V<br>~~pp~~|≤102V<br>~~pp~~|≤160V<br>~~pp~~|≤25V<br>~~pp~~|≤65V<br>~~pp~~|≤ UN+ 53V<br>~~pp~~|
|impD1 (Up)<br>VPL line-PG for IimpD1 (Up)<br>~~Po~~<br>~~GO~~|≤27V<br>~~pp~~<br>~~GO~~|≤37V<br>~~pp~~<br>~~GO~~|≤66V<br>~~pp~~<br>~~GO~~|≤95V<br>~~pp~~<br>~~GO~~|≤550V<br>~~pp~~<br>~~GO~~|≤550V<br>~~pp~~<br>~~GO~~|-<br>~~pp~~<br>~~GO~~|
|impD1 (Up)<br>VPL line-line at 1kV/μs C3 (Up)<br>~~GO~~|≤18V<br>~~GO~~|≤38V<br>~~GO~~|≤90V<br>~~GO~~|≤140V<br>~~GO~~|≤11V<br>~~GO~~|≤47V<br>~~GO~~|see Note 1<br>~~GO~~|
|line at 1kV/μs C3 (Up)<br>VPL line-PG at 1kV/μs C3 (Up)<br>~~GO~~|≤9V<br>~~GO~~|≤19V<br>~~GO~~|≤45V<br>~~GO~~|≤70V<br>~~GO~~|≤550V<br>~~GO~~|≤550V<br>~~GO~~|-<br>~~GO~~|
|PG at 1kV/μs C3 (Up)<br>VPL line-line for In C2 (Up)<br>~~GO~~|-<br>~~GO~~|-<br>~~GO~~|-<br>~~GO~~|-<br>~~GO~~|-<br>~~GO~~|-<br>~~GO~~|see Note 2<br>~~GO~~|
|line for In C2 (Up)<br>VPL line-PG for C2 / C3 / D1<br>~~OO~~|-<br>~~OO~~|-<br>~~OO~~|-<br>~~OO~~|-<br>~~OO~~|-<br>~~OO~~|-<br>~~OO~~|≤ 550V<br>~~OO~~|
|D1 Total lightning impulse current (10/350μs) (Iimp)<br>~~OO~~|10kA<br>~~OO~~|10kA<br>~~OO~~|10kA<br>~~OO~~|10kA<br>~~OO~~|10kA<br>~~OO~~|10kA<br>~~OO~~|10kA<br>~~OO~~|
|D1 Total lightning impulse current (10/350μs) (Iimp)<br>D1 Lightning impulse current (10/350μs) per line (Iimp)<br>~~GO~~|2.5kA<br>~~GO~~|2.5kA<br>~~GO~~|2.5kA<br>~~GO~~|2.5kA<br>~~GO~~|2.5kA<br>~~GO~~|2.5kA<br>~~GO~~|2.5kA<br>~~GO~~|
|D1 Lightning impulse current (10/350μs) per line (Iimp)<br>C2 Total nominal discharge current (8/20μs) (In)<br>~~OO~~|20kA<br>~~OO~~|20kA<br>~~OO~~|20kA<br>~~OO~~|20kA<br>~~OO~~|20kA<br>~~OO~~|20kA<br>~~OO~~|20kA<br>~~OO~~|
|C2 Nominal discharge current (8/20μs) per line (In)<br>~~GO~~|10kA<br>~~GO~~|10kA<br>~~GO~~|10kA<br>~~GO~~|10kA<br>~~GO~~|10kA<br>~~GO~~|10kA<br>~~GO~~|10kA<br>~~GO~~|
|Series impedance per line<br>~~GO~~<br>~~GO~~|1.0Ω<br>~~GO~~<br>~~GO~~|1.8Ω<br>~~GO~~<br>~~GO~~|1.8Ω<br>~~GO~~<br>~~GO~~|1.8Ω<br>~~GO~~<br>~~GO~~|1.0Ω<br>~~GO~~<br>~~GO~~|1.0Ω<br>~~GO~~<br>~~GO~~|10Ω/7.5Ω typ<br>~~GO~~<br>~~GO~~|
|Frequency of the operating voltage (fUN)<br>~~GO~~<br>~~OO~~|-<br>~~GO~~<br>~~OO~~|-<br>~~GO~~<br>~~OO~~|-<br>~~GO~~<br>~~OO~~|-<br>~~GO~~<br>~~OO~~|-<br>~~GO~~<br>~~OO~~|-<br>~~GO~~<br>~~OO~~|0-400Hz<br>~~GO~~<br>~~OO~~|
|Max. continuous operating DC voltage (UC)<br>~~OO~~<br>~~OO~~|6V<br>~~OO~~<br>~~OO~~|15V<br>~~OO~~<br>~~OO~~|33V<br>~~OO~~<br>~~OO~~|54V<br>~~OO~~<br>~~OO~~|6V<br>~~OO~~<br>~~OO~~|33V<br>~~OO~~<br>~~OO~~|180V<br>~~OO~~<br>~~OO~~|
|Max. continuous operating AC voltage (UC)<br>~~OO~~<br>~~GO~~|4.2V<br>~~OO~~<br>~~GO~~|10.6V<br>~~OO~~<br>~~GO~~|23.3V<br>~~OO~~<br>~~GO~~|38.1V<br>~~OO~~<br>~~GO~~|4.2V<br>~~OO~~<br>~~GO~~|23.3V<br>~~OO~~<br>~~GO~~|127V<br>~~OO~~<br>~~GO~~|
|Permissible superimposed signal voltage (USignal)<br>~~GO~~<br>~~po~~|~~GO~~|~~GO~~|~~GO~~|~~GO~~|~~GO~~|~~GO~~|± 5V<br>~~GO~~|
|Signal<br>"Nominal current at 80°C (IL)<br>(corresponds to max. short-circuit current)"<br>~~po~~|—|—|—|—|—|—|100mA|
|Cut-off frequency line-PG (fG)<br>~~po~~|1.0MHz|2.7MHz|6.8MHz|8.7MHz|100MHz|100MHz|-|
|Cut-off frequency line-line (USignal, balanced 100Ω) (fG)<br>~~po~~<br>~~OO~~|-<br>~~OO~~|-<br>~~OO~~|-<br>~~OO~~|-<br>~~OO~~|-<br>~~OO~~|-<br>~~OO~~|50MHz<br>~~OO~~|
|Signal<br>Capacitance line-line (C)<br>~~GO~~|≤2.7nF<br>~~GO~~|≤1.0nF<br>~~GO~~|≤0.5nF<br>~~GO~~|≤0.35nF<br>~~GO~~|≤25pF<br>~~GO~~|≤25pF<br>~~GO~~|≤80pF<br>~~GO~~|
|Capacitance line-PG (C)<br>~~OO~~|≤5.4nF<br>~~OO~~|≤2.0nF<br>~~OO~~|≤1.0nF<br>~~OO~~|≤0.7nF<br>~~OO~~|≤16pF<br>~~OO~~|≤16pF<br>~~OO~~|≤16pF<br>~~OO~~|
|ATEX Approvals<br>~~GO~~|†<br>~~GO~~|†<br>~~GO~~|†<br>~~GO~~|†<br>~~GO~~|†<br>~~GO~~|†<br>~~GO~~|—<br>~~GO~~|
|Agency information<br>~~GO~~<br>~~OO~~|††<br>~~GO~~<br>~~OO~~|††<br>~~GO~~<br>~~OO~~|††<br>~~GO~~<br>~~OO~~|††<br>~~GO~~<br>~~OO~~|††<br>~~GO~~<br>~~OO~~|††<br>~~GO~~<br>~~OO~~|‡<br>~~GO~~<br>~~OO~~|
|IEC 61643-21 Test category<br>~~OO~~<br>~~a~~|D1, C2, C3<br>~~OO~~|||||||
|Operating temperature range<br>~~a~~<br>~~a~~|-40°C to +80°C|||||||
|Degree of protection<br>~~a~~<br>~~a~~|IP20|||||||
|For mounting on<br>~~nO~~|35mm DIN-Rails per EN 60715<br>~~nO~~|||||||
|Grounding<br>~~a~~<br>~~pO~~|Via base part|||||||
|Color / enclosure material<br>~~pO~~<br>~~PO~~|Grey / Polyamide PA 6.6|||||||
|Test standards<br>~~pO~~<br>~~PO~~|IEC 61643-21 / EN 61643-21, UL 497B|||||||
|Connection (input / output)<br>~~PO~~<br>~~a~~<br>~~ep~~|Screw terminal<br>~~epDSo$€"w04. 9~~|||||||
|ConductorsSolid<br>Flexible<br>~~ep~~|12-28AWG (4-0.08mm2)<br>~~epDSo$€"w04. 9~~|||||||
||14-28AWG (2.5-0.08mm2)<br>~~epDSo$€"w04. 9~~<br>~~P|~~|||||||
|Terminal torque<br>~~ep~~<br>~~a~~|3.5 Lb-In (0.4 N•m)<br>~~ep DSo$€"w04. 9~~<br>~~a~~|||||||
|Warranty<br>~~I~~|5 Years*<br>~~I~~|||||||
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
## **0-180V SPD Application and Mode of Operation**
The BSPD0180DINL surge protective device automatically adjusts to the operating voltage (from 0 to 180 volts) of the protected device.
When an overvoltage event occurs, the SPD voltage protection level adjusts itself based upon the output terminal operating voltage of the base.
Note 1 - See Diagram 1 - VPL line-line graph line C3. Note 2 - See Diagram 1 - VPL line-line graph line C2.
- DEKRA 12ATEX0254 X: II 3 G Ex nA IIC T4 Gc
†† ATEX, UL, CSA
- UL 497B
## **Diagram 1: Voltage Protection Level Up (V) (Line - Line)**
**==> picture [227 x 165] intentionally omitted <==**
**----- Start of picture text -----**<br>
C2 = Up line-line for In (8/20 μs)<br>max. [V] C3 = Up line-line for 1kV/μs)<br>C2<br>200 V<br>ooo Up ooo C3<br>175 V Un<br>PTET T TT TT |<br>150 V<br>PITT TTT TTT TT a<br>125 V<br>tI | ee<br>100 V LT<br>75 V || eg<br>50 V<br>|| A<br>25 V 7<br>pr a UN<br>0 V 20 V 40 V 60 V 80 V 100 V 120 V 140 V 160 V 180 V<br>UN (Operating Voltage)<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**500**
**Overvoltage Devices**
## **DIN-Rail Universal 4 Wire Data Signal SPDs and Applications**
Universal 4 wire data signal SPD products are specified by communication technology. The table below contains the specific SPD product, by part number, and the applications to which they are suited to be used.
|Part Numbers|BSPD5DING|BSPD12DING|BSPD24DING|BSPD48DING|BSPD5DINLHF|BSPD24DINLHF|BSPD0180DINL|
|---|---|---|---|---|---|---|---|
|BUS SYSTEMS AND MEASURING,AND CONTROL TECHNOLOGY||||||||
|0-20 mA, 4-20 mA Signals<br>~~**a**~~|~~**a**~~|~~**a**~~<br>~~a~~|X<br>~~**a**~~|~~**a**~~|~~**a**~~|X (4-20mA only)<br>~~**a**~~|X<br>~~**a**~~|
|Binary Signals|X|X<br>~~a~~|X|X||||
|CAN-Bus (data line only)<br>~~**a**~~|~~**a**~~|~~a~~<br>~~**a**~~|~~**a**~~|~~**a**~~|X<br>~~**a**~~|~~**a**~~|X<br>~~**a**~~|
|C-Bus (Honeywell)|||||X||X|
|Data Highway Plus<br>~~Sf~~|~~Sf~~|~~Sf~~|~~Sf~~|~~Sf~~|~~Sf~~|~~Sf~~|X<br>~~Sf~~|
|Device Net (data line only)<br>~~Sf~~<br>~~a~~|~~Sf~~<br>~~a~~|~~Sf~~<br>~~a~~|~~Sf~~<br>~~a~~|~~Sf~~<br>~~a~~|X<br>~~Sf~~<br>~~a~~|~~Sf~~<br>~~a~~|X<br>~~Sf~~<br>~~a~~|
|Dupline<br>~~OO~~|~~OO~~|~~OO~~|~~EO~~|~~EO~~|~~EO~~||X|
|E-Bus (Honeywell)<br>~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|~~EO~~<br>~~a~~|~~EO~~<br>~~a~~|~~EO~~<br>~~a~~|~~a~~|X<br>~~a~~|
|Fieldbus Foundation<br>~~SO~~|~~SO~~|~~SO~~|~~SO~~|~~SO~~|~~SO~~|X<br>~~SO~~|X<br>~~SO~~|
|FIPIO / FIPWAY<br>~~**a**~~|~~**a**~~|~~**a**~~|~~**a**~~|~~**a**~~|~~**a**~~|X<br>~~**a**~~|~~**a**~~|
|FSK|||||X||X|
|IEC-Bus (RS485)<br>~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|X<br>~~a~~|~~a~~|X<br>~~a~~|
|Interbus INLINE (I/O)||~~ns~~|~~ns~~||||X|
|Interbus INLINE,<br>Long-distance bus<br>~~ss~~|~~ss~~|~~ss~~<br>~~ns~~|~~ss~~<br>~~ns~~|~~ss~~|X<br>~~ss~~|~~ss~~|X<br>~~ss~~|
|K Bus<br>~~**a**~~|~~**a**~~|~~ns~~<br>~~**a**~~<br>~~a~~|~~ns~~<br>~~**a**~~|~~**a**~~|~~**a**~~|X<br>~~**a**~~|~~**a**~~|
|LON-TP/XF 78||~~a~~|||X|||
|LUXMATE Bus<br>~~OO~~|~~OO~~|~~a~~<br>~~OO~~|~~OO~~|~~OO~~|~~OO~~|X<br>~~OO~~|X<br>~~OO~~|
|M Bus<br>~~OO~~<br>~~**a**~~|~~OO~~<br>~~**a**~~|~~OO~~<br>~~**a**~~|~~OO~~<br>~~**a**~~|~~OO~~<br>~~**a**~~|~~OO~~<br>~~**a**~~|~~OO~~<br>~~**a**~~|X<br>~~OO~~<br>~~**a**~~|
|MODBUS|||||X||X|
|MPI Bus<br>~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|X<br>~~a~~|~~a~~|X<br>~~a~~|
|Procontic CS31 (RS232)<br>~~OO~~|~~OO~~|X<br>~~OO~~|~~OO~~|~~OO~~|~~OO~~|~~OO~~|~~OO~~|
|Procontic T200 (RS422)<br>~~**a**~~|~~**a**~~|~~**a**~~<br>~~a~~|~~**a**~~|~~**a**~~|X<br>~~**a**~~|~~**a**~~|X<br>~~**a**~~|
|PROFIBUS DP/FMS||~~a~~|||X||X|
|PROFIBUS PA<br>~~**a**~~|~~**a**~~|~~a~~<br>~~**a**~~|~~**a**~~|~~**a**~~|~~**a**~~|X<br>~~**a**~~|X<br>~~**a**~~|
|PROFIBUS SIMATIC NET|||||X||X|
|PSM EG RS422 & RS485<br>~~**a**~~|~~**a**~~|~~**a**~~<br>~~a~~|~~**a**~~|~~**a**~~|X<br>~~**a**~~|~~**a**~~|X<br>~~**a**~~|
|Rackbus (RS485)||~~a~~|||X||X|
|R Bus<br>~~OO~~|~~OO~~|~~a~~<br>~~OO~~|~~OO~~|~~OO~~|X<br>~~OO~~|~~OO~~|X<br>~~OO~~|
|RS 485<br>~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|X<br>~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|X<br>~~OO~~<br>~~a~~|
|RS422, V11<br>~~OO~~|~~OO~~|~~OO~~|~~OO~~|~~OO~~|X<br>~~OO~~|~~OO~~|X<br>~~OO~~|
|SafetyBUS p<br>~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|X<br>~~OO~~<br>~~a~~|~~OO~~<br>~~a~~|X<br>~~OO~~<br>~~a~~|
|Securilan LON Bus<br>~~OO~~|~~OO~~|~~OO~~|~~OO~~|~~OO~~|X<br>~~OO~~|~~OO~~|~~OO~~|
|SIGMASYS<br>~~a~~|~~a~~|~~a~~|~~a~~|X<br>~~a~~|~~a~~|~~a~~|~~a~~|
|SS97 SIN/X (RS 232)<br>~~OO~~|~~OO~~|X<br>~~OO~~|~~OO~~|~~OO~~|~~OO~~|~~OO~~|~~OO~~|
|SUCONET<br>~~a~~|~~a ~~|~~OO~~|~~OO~~|~~OO~~|X<br>~~OO~~||X|
|Resistance Temp. Measuring<br>Ni1000, PT100, PT1000 Wire<br>NTC & PTC Thermistors||X||||||
|TTL||X||||||
|TTY 4–20mA<br>~~a~~|~~a~~|~~a~~|X<br>~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|
|TELECOMMUNICATION, TELEPHONY||||||||
|a/b Wires<br>~~a~~|~~a~~|~~a~~|~~a~~<br>~~GG~~|~~a~~<br>~~GG~~|~~a~~<br>~~GG~~|~~a~~|X<br>~~a~~|
|ADSL, ADSL 2+<br>~~GG~~|~~GG~~|~~GG~~|~~GG~~|~~GG~~|~~GG~~|~~GG~~|X<br>~~GG~~|
|ISDN S~~0~~, S2~~m~~/U2~~m,~~U~~KO~~/U~~PO~~<br>~~GG~~<br>~~**a**~~|~~GG~~<br>~~**a**~~|~~GG~~<br>~~**a**~~|~~GG~~<br>~~**a**~~|~~GG~~<br>~~**a**~~|~~GG~~<br>~~**a**~~|~~GG~~<br>~~**a**~~|X<br>~~GG~~<br>~~**a**~~|
|~~0mm,KOPO~~<br>Modem M1||X||||||
|SDSL, SHDSL<br>~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|X<br>~~a~~|X<br>~~a~~|
|Telephony Systems<br>(e.g., Siemens, HICOM, Alcatel)|||~~a~~||||X|
|T-DSL<br>~~a~~|~~a~~|~~a~~|~~a~~<br>~~a~~|~~a~~|~~a~~|~~a~~|X<br>~~a~~|
|Telecommunication Systems<br>(e.g., Siemens, HICOM, Alcatel)|||~~a~~||||X|
|VDSL|||||||X|
|DATA NETWORKS<br>~~TT~~||||||||
|V 24 (RS232 C)<br>~~GG~~|~~GG~~|X<br>~~GG~~|~~GG~~|~~GG~~|~~GG~~|~~GG~~|~~GG~~|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**501**
**Overvoltage Devices**
## **SurgePOD™ Series**
## **Surge Protective Overvoltage Device Modules**
## **Pb**
## **Description**
Bussmann SurgePOD surge protective overvoltage device modules are board-mounted. Upon an overvoltage condition, their voltage clamping feature becomes conductive, safely shunting the surge to ground.
All SurgePOD devices are UL 1449 3[rd] Edition Recognized Type 1 SPD and contain an internal element that safely disconnects the device upon reaching an overvoltage breakdown condition.
_Remote contact signaling_ is accomplished with an optional _Normally Open_ microswitch that closes upon reaching an overvoltage breakdown condition.
_Local visual indication_ is accomplished with optional visual indicating tabs that protrude through the device’s top upon reaching an overvoltage breakdown condition.
The SurgePOD’s MOV substrate material may be damaged by excessive shock or rough handling. To ensure integrity of finished device, do NOT install any SurgePOD devices that are dropped or abused during assembly.
Catalog Number System:
SPOD 320 S T R
Series: SPOD MCOV: 150, 270, 320, 420, 510, 550 Lead Length: S = Short - 6.87mm L = Long - 16.76mm Visual Indicator Tab: T = Yes Blank = None Remote Contact Signaling: R = Yes (Normally Open) Blank = None
## **Agency Information**
UL 1449 3[rd] Edition Recognized Type 1 Surge Protective Device; File E340782.
## **Electrical Specifications**
|Maximum Continuous Operating Voltage (MCOV)|150Vac to 550Vac|
|---|---|
|Short-Circuit CurrentRating (SCCR)|200kA|
|Nominal Discharge Current (In) 8/20ms|20kA|
|Max Discharge CurrentRating (Imax) 8/20ms|50kA|
|Remote Contact Signaling Microswitch|20mA@15Vdc|
Suitability of SurgePOD devices for application to be determined by end user.
|SurgePOD<br>Specifications|Voltage / Color Code|Voltage / Color Code|Voltage / Color Code|Voltage / Color Code|Voltage / Color Code|Voltage / Color Code|
|---|---|---|---|---|---|---|
||150V|270V|320V|420V|510V|550V|
|In|20kA|20kA|20kA|20kA|20kA|20kA|
|Imax|50kA|50kA|50kA|50kA|50kA|50kA|
|SCCR|200kA|200kA|200kA|200kA|200kA|200kA|
|MCOV(Vrms)|150V|270V|320V|420V|510V|550V|
|VPR|600V|900V|1200V|1500V|1500V|1500V|
|Nominal Vrms*|120V|220V|277V|347V|480V|480V|
* Nominal Vrms @ 50/60Hz.
## **Data Sheet: 1170**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle **502**
**Overvoltage Devices** ee ~~: ee~~ **SurgePOD™ Series**
## Mechanical Specifications
All components are rated IP20 finger-safe in the installed state.
## Environmental Specifications
**==> picture [242 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
Plastic Material: Polybutylene Terephthalate<br>Flammability Rating: UL 94V0<br>Storage Temperature: -25°C to 85°C<br>Operating Temperature: -25°C to 85°C<br>Local Visual Indication Tabs (Optional)<br>SurgePOD Local visual indication<br>device under tabs exposed upon<br>normal reaching an overvoltage<br>operation. breakdown condition.<br>=| “|<br>**----- End of picture text -----**<br>
## Dimensions - in [mm]
Tolerance is ± 0.005” [0.13mm] unless otherwise stated.
**==> picture [261 x 346] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.195±0.01 Indication tab Leads for optional<br>[4.95±0.25] deployed. remote contact signaling.<br>~<br>Productivity Through Protection™<br>Long<br>Terminals<br>0.627±0.01<br>[15.92±0.25]<br>1.000±0.01<br>[25.40±0.25] Side View<br>@) 1.687 @)<br>[42.85]<br>0.143<br>Front View<br>[3.63]<br>coof e r Top View<br>Productivity Through Protection™<br>Short<br>LL Terminals<br>0.280<br>[7.11]<br>Front View<br>0.100 [2.54]<br>]<br> Ref<br>1.684 42.77[<br>2.930 [74.43] 0.660 [16.76]<br>0.349 [8.87]<br>0.22±0.05 [5.58±1.27]<br>**----- End of picture text -----**<br>
## Terminal Dimensions / Pad Layout - in [mm]
**==> picture [246 x 386] intentionally omitted <==**
**----- Start of picture text -----**<br>
2x 0.325<br>[8.26]<br>1 ar<br>|<br>Front 0.407<br>1.375 [10.34]<br>[34.93]<br>1.687<br>[42.85]<br>Dimension A<br>MCOV Rating Inches mm<br>150 0.431 10.95<br>270, 320 P 0.479 12.17 L<br>420, 510, 550 0.526 13.36<br>Terminal Information and Mounting<br>The SurgePOD surge protective overvoltage devices have nickel-plated copper<br>terminals for easy solder connection to printed circuit boards.<br>Recommended Pad Layout for Remote Contact Signaling - in [mm]<br>0.195<br>[4.9] 0.184<br>[4.67]<br>- -<br>0.747<br>| [18.97]<br>[0.94]<br>2x 0.037<br>±0.01 ±0.25]<br>0.126 [3.20] A<br>0.627 [15.92<br>0.050 [1.27]<br>[0.99]<br>2x ø 0.039<br>0.231 [5.87] 0.228 [5.79]<br>**----- End of picture text -----**<br>
## Terminal Information and Mounting
The SurgePOD surge protective overvoltage devices have nickel-plated copper terminals for easy solder connection to printed circuit boards.
## Recommended Pad Layout for Remote Contact Signaling - in [mm]
## Packagin ~~g~~ Information
**==> picture [93 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
• 200 units per master pack<br>**----- End of picture text -----**<br>
**Data Sheet: 1170**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**503**
**Overvoltage Devices**
## **DIN-Rail TVS Series**
OFF - Suppressor Non-Operational (power may be on) GREEN - Suppressor Operational (power on)
## **Specifications**
**==> picture [72 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions -in<br>**----- End of picture text -----**<br>
**Description:** DIN-Rail mount voltage surge protection system for AC or DC voltage using diode or MOV technology.
## **Construction:**
**Suppressor:** Case: 20% glass filled PES (Polyethersulfone) Terminals: 110 Copper Terminal Plating: Electroless tin **Holder:** Case: 15% glass filled PBT (Polybutylene Terephthalate) Interface Clips: CDA 7025 Interface Clip Plating: Electroless tin Contact Lubricant: Fluoroether grease Box Lug: Copper DIN-Rail Springs: Stainless steel
**==> picture [55 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power Terminals<br>14AWG - 4AWG<br>Dual 10AWG<br>**----- End of picture text -----**<br>
## **Ratings*:**
Volts: — 12Vdc (2kA surge current)
- 24Vdc (2kA surge current)
— 48Vdc (2kA surge current) — 120Vac (7kA-18kA surge current) — 240Vac (7kA-18kA surge current)
* See Catalog Numbers table for all specifications pertaining to specific voltage ratings. **Agency Information:** UL Recognized (UL 1449) for AC products, (UL 497B) for DC products, CSA Approved.
## **Product Specifications:**
1. All TVS devices have non-polarized electrical connections as shown.
2. Suppressor voltage characteristics per chart.
3. Suppressor to provide non-interrupted service.
4. Enclosure material is 94V0 flame and explosion resistant.
5. Product markings show manufacturer, part number and safety warnings as required.
6. Mechanical dimensions as noted.
7. Suppressor Status LED as shown.
8. AC units operate on either 50 or 60Hz.
## **Catalog Numbers**
|**Catalog**|**Voltage**|||**SVR**|**Surge Current**|**Agency**|**Label**|
|---|---|---|---|---|---|---|---|
|**Numbers**|**Application**|**MCOV**|**Technology**|**500A, 8x20μs**|**Rating**|**Information**|**Color**|
|TVS12DCD|12Vdc|14Vdc|SASD|36Vdc|2kA|UL 497B|Red|
|TVS24DCD|24Vdc|28Vdc|SASD|58Vdc|2kA|UL 497B|White|
|TVS48DCD|48Vdc|57Vdc|SASD|90Vdc|2kA|UL 497B|Black|
|TVS120ACD|120Vac|140Vac|SASD|330Vac|7kA|UL 1449|Blue|
|TVS120ACM|120Vac|140Vac|MOV|500Vac|18kA|UL 1449|Grey|
|TVS240ACD|240Vac|280Vac|SASD|600Vac|7kA|UL 1449|Blue|
|TVS240ACM|240Vac|280Vac|MOV|800Vac|18kA|UL 1449|Grey|
## **Data Sheet: 9006**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**504**
## **Reduce Downtime With Quick Access to the Right Replacement Fuse**
**==> picture [247 x 275] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Section Contents Page|
|Fuse Service Kits|
|Supplemental|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506-507|
|Branch circuit|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506-507|
|Premium branch circuit . . . . . . . . . . . . . . . . . . . . . . 506-507|
|Large electronic|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508|
|Small electronic|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508|
|Electrical & electronic. . . . . . . . . . . . . . . . . . . . . . . . . . . 508|
|Clips clamps & rail adapters (DIN & American)|. . . . . 509|
|Spare fuse holders, pullers, testers & cabinets|
|Telepower spare fuse holders|. . . . . . . . . . . . . . . . . . . . 510|
|5TPH|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510|
|Fuse pullers|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510|
|FT-2 & FT-3 fuse testers|. . . . . . . . . . . . . . . . . . . . . . . . 510|
|SFC spare fuse cabinet|. . . . . . . . . . . . . . . . . . . . . . . . . 510|
|Fuse reducers & dummy “neutrals”|
|Class J fuses - LPJ, JKS|. . . . . . . . . . . . . . . . . . . . . . . . 511|
|Class R fuses - FRN-R, LPN-RK, FRS-R|
|& LPS-RK|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 511|
|Class H & K fuses - NON, REN, NOS & RES|. . . . . . . . 511|
|Dummy fuse “neutrals” . . . . . . . . . . . . . . . . . . . . . . . . . . 511|
**----- End of picture text -----**<br>
**505**
**Fuse Kits and Accessories**
## **Fuse Service Kits**
## **Save Time and Money with These Fuse Service Kits**
## **Selection**
These service kits are filled with the most common fuse types and sizes for the most common applications – no need to search for the right fuse, it’s in the kit.
## **Organization**
The compact and sturdy carrying case allows organizing and modifying the fuses needed to assure a proper supply is kept on hand.
## **Accessories**
All kits come with a fuse puller for the fuses it contains. As a bonus, all kits on this page include a free wire stripper or lineman’s pliers.
## **Supplemental**
## **Glass Fuse Kit**
**Catalog Number: GSK-260 Kit Contents**
(5) GMA-500mA (5) MDL-6 (5) AGC-10 (5) GMA-1A (5) MDL-7 (5) AGC-15 (5) GMA-2A (5) MDL-8 (5) AGC-20 (5) GMA-3A (5) MDL-10 (5) GMC-2A (5) GMA-4A (5) MDL-15 (5) GMC-5A (5) GMA-5A (5) MDL-20 (5) GMC-10A (5) GMA-6A (5) AGC-[1] ⁄4 (5) MDA-5 (5) GMA-10A (5) AGC-[1] ⁄2 (5) MDA-10 (5) GMA-15A (5) AGC-1 (5) MDA-12 (5) MDL-[1] ⁄4 (5) AGC-1[1] ⁄2 (5) MDA-15 (5) MDL-[1] ⁄2 (5) AGC-2 (5) MDA-20 (5) MDL-1 (5) AGC-2[1] ⁄2 (5) ABC-5 (5) MDL-1[1] ⁄2 (5) AGC-3 (5) ABC-10 (5) MDL-2 (5) AGC-4 (5) ABC-12 (5) MDL-2[1] ⁄2 (5) AGC-5 (5) ABC-15 (5) MDL-3 (5) AGC-6 (5) ABC-20 (5) MDL-4 (5) AGC-7 (5) MDL-5 (5) AGC-8
## **Branch Circuit**
## **Class CC Fuse Kit**
## **Catalog Number: CCSK-45**
## **Kit Contents**
(3) LP-CC-5 (3) KTK-R-15 (3) LP-CC-10 (3) KTK-R-20 (3) LP-CC-15 (3) KTK-R-30 (3) LP-CC-20 (3) FNQ-R-[1] ⁄2 (3) LP-CC-30 (3) FNQ-R-3 (3) KTK-R-5 (3) FNQ-R-5 (3) KTK-R-10 (3) FNQ-R-10 (1) FT-3 Fuse tester/puller
(1) 6-inch Crescent[®] wire stripper
## **Premium Branch Circuit**
## **Low-Peak[™] Class RK1 250/600V Fuse Kit**
## **Catalog Number: RK1SK-39**
## **Kit Contents**
(3) LPN-RK-10SP (3) LPS-RK-10SP (3) LPN-RK-15SP (3) LPS-RK-15SP (3) LPN-RK-20SP (3) LPS-RK-20SP (3) LPN-RK-25SP (3) LPS-RK-30SP (3) LPN-RK-30SP (3) LPS-RK-60SP (3) LPN-RK-60SP (3) LPS-RK-100SP
(3) LPN-RK-100SP
(1) NO.263-R (60 to 30A fuse reducer) (1) NO.663-R (60 to 30A fuse reducer)
(1) FP-2 Fuse puller
(1) 8[5] ⁄8-inch Crescent[®] lineman’s pliers
(1) FT-3 Fuse tester/puller
(1) 6-inch Crescent[®] wire stripper
**Midget Fuse Kit Catalog Number: MSK-45 Kit Contents**
(3) FNM-1 (3) KTK-20 (3) FNM-2 (3) KTK-30 (3) FNM-5 (3) FNQ-5 (3) FNM-10 (3) FNQ-10 (3) FNM-15 (3) FNQ-15 (3) KTK-5 (3) FNQ-20 (3) KTK-10 (3) FNQ-30 (3) KTK-15 (1) FT-3 Fuse tester/puller
(1) 6-inch Crescent[®] wire stripper
**Fusetron[™] Class RK5 250/600V Fuse Kit Catalog Number: RK5SK-39**
## **Kit Contents**
|(3) FRN-R-10|(3) FRN-R-10<br>(3) FRS-R-10|
|---|---|
|(3) FRN-R-15<br>(3) FRN-R-20<br>(3) FRN-R-25<br>(3) FRN-R-30<br>(3) FRN-R-60<br>(3) FRN-R-100<br>(1) NO.263-R (60 to 30A fuse reducer)<br>(1) NO.663-R (60 to 30A fuse reducer)<br>(1) 6-inch Crescent|(3) FRN-R-15<br>(3) FRS-R-15<br>(3) FRN-R-20<br>(3) FRS-R-20<br>(3) FRN-R-25<br>(3) FRS-R-30<br>(3) FRN-R-30<br>(3) FRS-R-60<br>(3) FRN-R-60<br>(3) FRS-R-100<br>(3) FRN-R-100<br>(1) FP-2 Fuse puller<br>(1) NO.263-R (60 to 30A fuse reducer)<br>(1) NO.663-R (60 to 30A fuse reducer)<br>(1) 6-inch Crescent® wire stripper|
## **Low-Peak[™] Class J Fuse Kit**
## **Catalog Number: JSK-36**
## **Kit Contents**
(3) LPJ-3SP (3) LPJ-25SP (3) LPJ-5SP (3) LPJ-30SP (3) LPJ-6SP (3) LPJ-40SP (3) LPJ-10SP (3) LPJ-50SP (3) LPJ-15SP (3) LPJ-60SP (3) LPJ-20SP (3) LPJ-100SP (1) FP-2 Fuse puller (1) 8[5] ⁄8-inch Crescent[®] lineman’s pliers
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**506**
**Fuse Kits and Accessories**
## **Fuse Service Kits**
## **Supplemental/Branch Circuit**
## **Class CC / Midget Fuse Kit**
Emergency fuse kit for replacement of 13⁄32˝ x 11⁄2˝ (Class CC and midget) fuses in a sturdy nylon box. Cross reference makes it easy to install the correct fuse in any Class CC or midget application. **Kit Size:** 10[7] ⁄8˝ W x 6[5] ⁄8˝ D x 1[3] ⁄4˝ H
## **Catalog Number: NO.36**
## **Emergency Kit Contents**
(2) FNQ-R-1⁄2 (2) KTK-R-1 (2) FNQ-R-1 (2) KTK-R-2 (2) FNQ-R-2 (2) KTK-R-3 (2) FNQ-R-3 (2) KTK-R-5 (2) FNQ-R-4 (2) KTK-R-6
(2) FNQ-R-5 (2) KTK-R-10 (2) FNQ-10 (2) KTK-R-15 (2) FNQ-15 (2) KTK-R-20 (2) FNQ-20 (2) KTK-R-30
## **Branch Circuit**
## **Fusetron[™] Class RK5 250V Fuse Kit**
Compact kit in a sturdy nylon box rugged enough to withstand field use. Extra spaces and changeable compartments make it easy to customize for your particular need.
## **Catalog Number: ERK-28**
## **Service Kit Contents**
2 (2) FRN-R-3⁄10 (2) FRN-R-40 (2) FRN-R-6-1⁄4 (2) FRN-R-50
- (2) FRN-R-10
(3) FRN-R-60 (2) FRN-R-100
(2) FRN-R-15
(2) NO.263-R Reducers
(3) FRN-R-20
(2) NO.1 Clip Clamps
(2) FRN-R-25
(2) NO.2 Clip Clamps
- (4) FRN-R-30
(2) FRN-R-35
## **Premium Branch Circuit**
## **Low-Peak[™] Class RK1 250V Fuse Kit**
Compact kit in a sturdy nylon box rugged enough to withstand field use. Extra spaces and changeable compartments make it easy to customize for your particular need.
## **Catalog Number: LPRK-28**
## **Service Kit Contents**
- 2
- (2) LPN-RK-3⁄10SP
(2) LPN-RK-40SP (2) LPN-RK-50SP (3) LPN-RK-60SP (2) LPN-RK-100SP (2) NO.263-R Reducers
- (2) LPN-RK-6-1⁄4SP
- (2) LPN-RK-10SP
- (2) LPN-RK-15SP
- (3) LPN-RK-20SP
- (2) LPN-RK-25SP (2) NO.1 Clip Clamps
- (4) LPN-RK-30SP (2) NO.2 Clip Clamps
- (2) LPN-RK-35SP (1) FP-2 Fuse puller
(1) FP-2 Fuse puller
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**507**
**Fuse Kits and Accessories**
## **Fuse Service Kits**
## **Large Electronic Fuse Kit**
## **Fuse Kit 270**
Small dimension fuse assortment with 270 fuses, fuse holders, fuse blocks and fuse clips to fit most electronic equipment.
## **Ratings:**
Volts: — 125V/250V
**Catalog Number: NO.270**
## **Assortment Contents**
(5) MDL-1⁄8 (5) AGC-1⁄2 (5) GMA-1A (5) MDL-1⁄4 (5) AGC-3⁄4 (5) GMA-2A (5) MDL-1⁄2 (5) AGC-1 (5) GMA-3A (5) MDL-3⁄4 (5) AGC-1-1⁄2 (5) GMA-4A (5) MDL-1 (5) AGC-2 (5) GMA-6A (5) MDL-1-1⁄2 (5) AGC-2-1⁄2 (5) GMC-1A (5) MDL-2 (5) AGC-3 (5) GMC-2A (5) MDL-3 (5) AGC-4 (5) GMC-3A (5) MDL-4 (5) AGC-5 (5) GMC-4A (5) MDL-5 (5) AGC-6 (5) GMC-6A (5) MDL-6 (5) AGC-7 (4) AGC-V-1⁄21⁄2⁄22
(5) MDL-4 (5) AGC-5 (5) GMC-4A (5) MDL-5 (5) AGC-6 (5) GMC-6A (5) MDL-6 (5) AGC-7 (4) AGC-V-1⁄21⁄2⁄22 (5) MDA-8 (5) AGC-8 (4) AGC-V-1 (5) MDA-10 (5) ABC-10 (4) AGC-V-2 (5) MDA-15 (5) ABC-15 (4) AGC-V-3 (5) MDA-20 (5) ABC-20 (4) MDL-V-1⁄2 (5) MDA-30 (5) ABC-30 (4) MDL-V-1 (5) AGC-1⁄8 (5) GMA-250mA (4) MDL-V-2 (5) AGC-1⁄4 (5) GMA-500mA (4) MDL-V-3 (2) Pr. 4121 Fuse clips
## **Small Electronic Fuse Kit**
## **Fuse Kit 140**
Small dimension fuse kit with 140 fuses, fuse holders, fuse blocks and fuse clips to fit most electronic equipment.
**Ratings:**
Volts: — 125V/250V
**Catalog Number: NO.140**
## **Assortment Contents**
- (5) MDL-1⁄2
(5) AGC-1-1⁄2 (5) AGC-2 (5) AGC-3
(5) MDL-1
- (5) MDL-1-1⁄2 (5) MDQ-2
(5) MTH-4
(5) MDQ-3 (5) MTH-5
(5) MDQ-4
(5) MTH-6
(5) MDQ-5 (5) MTH-7
(5) MDQ-6 (5) MTH-8
(5) MDA-8 (5) ABC-10
(5) MDA-10 (5) ABC-15 (5) MDA-15 (5) ABC-20 (5) MDA-20 (5) ABC-30
(5) MDA-30 (2) Pr. #4121 Fuse clips (5) AGC-1⁄41⁄4⁄44 (2) HHB Inline fuse holder (5) AGC-1⁄21⁄2⁄22 (1) FP-A3 Fuse puller
(5) AGC-1⁄41⁄4⁄44 (5) AGC-1⁄21⁄2⁄22 (5) AGC-1
## **Electrical and Electronic Fuse Kit**
## **5 x 20mm Fuse Kit 220**
A complete assortment of 125V and 250V 5 x 20mm fuses for the repair of both electrical and electronic devices. **Ratings:** Volts: — 125V/250V
## **Catalog Number: NO.220**
## **Assortment Contents**
(5) GMA-250mA (5) GDA-6.3 (5) GMD-200mA (5) GMA-500mA (5) GDB-630mA (5) GMD-500mA (5) GMA-1 (5) GDB-2 (5) GMD-1 (5) GMA-1.5 (5) GDB-3.15 (5) GMD-1.6 (5) GMA-2 (5) GDB-4 (5) GMD-2 (5) GMA-2.5 (5) GMC-500mA (5) GMD-3 (5) GMA-3 (5) GMC-750mA (5) GDC-250mA (5) GMA-4 (5) GMC-1 (5) GDC-500mA (5) GMA-5 (5) GMC-2 (5) GDC-1 (5) GMA-10 (5) GMC-2.5 (5) GDC-1.6 (5) GDA-630mA (5) GMC-3 (5) GDC-2 (5) GDA-1 (5) GMC-3.15 (5) GDC-3.15 (5) GDA-2 (5) GMC-4 (5) GDC-4 (5) GDA-3.15 (5) GMC-5 (5) GDC-5 (5) GDA-5 (5) GMC-6.3 (1) HTB-28M panel mount fuse holder
(1) FP-A3 Fuse puller
(2) HHB Inline fuse holder
(1) HTB-26I panel mount fuse holder
(1) HTB-28M panel mount fuse holder
(1) S-8202-2 Two-pole fuse block
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**508**
**Fuse Kits and Accessories**
## **Clip Clamps and Rail Adapters (DIN & American)**
## **TRON™ Clip-Clamps**
**Specifications Description:** Clamps for ferrule and bladetype cartridge fuse clips. Provide tight contacts between fuse holder clips and fuse ferrules/blades.
**Construction:** Phenolic knob and plated-steel jaws.
|**Catalog Numbers**<br>**Catalog**<br>**Numbers**<br>NO.1|**Catalog Numbers**<br>**Clamp Size**<br>**Volts**<br>250|**Amps**<br>0-30|
|---|---|---|
|NO.2|250|35-60|
|NO.2<br>NO.4|600<br>600|0-30<br>35-60|
|NO.5|250/600|70-100|
|NO.6<br>NO.7<br>NO.8|250/600<br>250/600<br>250/600|110-200<br>225-400<br>450-600|
## **Adapters for DIN and American Rails**
**Specifications Description:** Bussmann DIN-Rail adapters permit secure, positive snap-on mounting of Bussmann 0-30A fuse blocks (one-, two-, or three-pole) onto various size rails to eliminate costly and time consuming drilling, tapping, and screw mounting. Adapters mechanically lock into mounting holes of fuse blocks in seconds to become an integral part of the block. One adapter is required for one- and two-pole Bussmann blocks. Two adapters are required for three-pole blocks. With the exception of the 32mm DIN-Rail, all blocks with adapters can be removed from a rail simply by pulling up its release tab.
Use of rail end-stops on both sides of adapters is recommended.
**Construction:** Molded from “Lexan™ 241” for high strength and flexibility.
## **Catalog Numbers (For 0-30A Fuse Blocks)**
|**Catalog**|**Fuse Block**|||**Adapter**|
|---|---|---|---|---|
|**Numbers**|**Class**|**Rail Type**|**Size**|**Color**|
|DRA-1|CC|DIN|15mm (Sym.)|Black|
||G||32mm (Asym.)||
||*H (250V)||35mm (Sym.)||
|DRA-2|*R (250)|American|17⁄64˝ (Sym.)|Gray|
||M Type||(also 35mm DIN)||
Package Quantities: standard—10; bulk—100 (Cat. No. BK/DRA-1 or BK/DRA-2.)
*Mounting on 15mm rails is not recommended.
NOTE—Newer Bussmann fuse blocks have elongated block-to-adapter mounting holes (old style fuse blocks will not accept the rail adapters).
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**509**
**Fuse Kits and Accessories**
## **Spare Fuse Holders, Pullers, Testers and Cabinets**
## **Spare Fuse Holders**
## **Fuse Pullers**
## **SFC Spare Fuse Cabinet**
## **Specifications**
**Description:** Spare fuse holders durably constructed using black thermoplastic with common mounting using #6 screws or bolts on 5-inch centers. Dovetailed interlocking between fuse holders simplifies installation and reduces needed hardware. Common footprint allows for any combination of fuse holders to be mounted together. Built-in retaining clips secure fuses. **Flammability Rating:** UL 94V0.
## **Catalog Numbers**
**Catalog Numbers Capacity For Use With:** TPSFH-CW 4-position TPC and/or TPW fuses TPSFH-M 4-position TPM fuses TPSFH-LC 1-position TPL-C series fuses TPSFH-LB 1-position TPL-B series fuses TPSFH-N60 1-position TPN (35-60A) fuses TPSFH-N30 4-position TPN (1-30A) fuses TPSFH-AS 6-position TPA & TPS fuses TPSFH-T 10-position GMT fuses
**FP-2 FP-6 FP-3 CFP-_ _ _A** ~~—~~ **FP-4** = **FP-A3 Specifications Description:** Fuse pullers in various sizes to safely and easily extract fuses from blocks and holders.
## **Catalog Numbers**
**Ca** FP- **t** 2 **alog Numbers** 13 **Application** ⁄32˝ to 13⁄16˝ dia. fuses FP-3 1˝ to 1[3] ⁄4˝ dia. fuses FP-4 1[3] ⁄4˝ to 2[1] ⁄2˝ dia. fuses FP-6 0-60A T-Tron fuses FP-A3 Glass Tube & ATC fuses CFP-30 CUBEFuse 1-30A CFP-60 CUBEFuse 35-60A CFP-100 CUBEFuse 70-100A Fuse pullers are only to be used when the associated circuit has been de-energized.
## **FT-2 Fuse Tester**
## **Specifications**
**Description:** Spare fuse cabinet with five cubic feet of storage space. Constructed of heavy gauge steel with durable baked ASA 61 grey enamel finish. Cabinet door is equipped with locking handle for security. Mounting holes are 16 inches on center with key slots.
**Size:** 24˝ W x 30˝ H x 12˝ D **Material:** 0.062 sheet steel
## **Catalog Numbers:**
SFC-FUSE-CAB
SFC-SHELF* *Extra shelf for fuse cabinet.
**Data Sheet: 1119**
## **5TPH**
## **FT-3 Fuse Tester**
## **Specifications**
## **Specifications**
**Description:** 5-position spare fuse holder for midget size and Class CC fuses ([13] ⁄32˝ diameter) fuses. Constructed of thermoplastic with adhesive tape on back for easy mounting on cabinet doors. **Size:** 2.98˝ W x 1.03˝ H x 0.63˝ D
## **Catalog Number: 5TPH**
## **Data Sheet: 5014**
**Description:** Fuse tester for automotive, ˝ glass tube and ferrule fuses up to 1[7] ⁄8 length. Probe slides to appropriate fuse length. Batteries are included and replaceable.
**WARNING** : _**DO NOT**_ test electrical fuses in the fuse panel.
## **Catalog Number: FT-2**
**Replacement Battery:** Rayovac 364
## **Specifications**
**Description:** Fuse tester for automotive, glass tube and ferrule fuses up to 1[1] ⁄4˝ length. Probe slides to appropriate fuse length. Batteries are included and replaceable.
**WARNING** : _**DO NOT**_ test electrical fuses in the fuse panel.
## **Catalog Number: FT-3**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**510**
**Fuse Kits and Accessories**
## **Fuse Reducers and Dummy “Neutrals”**
## **Fuse Reducers for Class J Fuses: LPJ, DFJ, JKS**
## **Catalog Numbers**
|**Catalog**<br>**Numbers (Pair)**<br>**Reducer No.**<br>J-63|**Fuse**<br>**Amp Size Range**<br>1-30|**Equipment/Fuseblock**<br>**Amp Size**<br>60|
|---|---|---|
|J-13|1-30|100|
|J-16<br>J-26<br>J-21<br>J-41<br>J-42<br>J-62<br>J-64<br>†Not for Bolt-on Applications.|35-60<br>35-60<br>70-100<br>70-100<br>110-200<br>110-200<br>225-400|100<br>200†<br>200†<br>400†<br>400†<br>600†<br>600†|
## **Fuse Reducers for Class R Fuses: FRN-R, LPN-RK, FRS-R, LPS-RK KTN-R, KTS-R UL Listed File E12853**
## **Dummy Fuse “Neutrals” (These are not fuses)**
## **Catalog Numbers**
||**Fuse Equivalent**|**Fuse Equivalent**|**Fuse Equivalent**|
|---|---|---|---|
|**Catalog**<br>**Numbers**|**Fuse Equivalent**<br>**Fuse**<br>**Voltage**<br>**Dimension**<br>**Amp Size Range**|||
||**Voltage**|**Dimension**||
|NNB|—|13⁄32˝x 11⁄2˝|—|
|NNB-R|—|Class CC|—|
|NNC|—|1⁄4˝x 11⁄4”|—|
|NTN-R-30|250|R/H|1-30|
|NTN-R-60|250|R/H|35-60|
|NTN-R-100|250|R/H|70-100|
|NTN-R-200|250|R/H|110-200|
|NTN-R-400|250|R/H|225-400|
|NTS-R-30|600|R/H|1-30|
|NTS-R-60|600|R/H|35-60|
|NTS-R-100|600|R/H|70-100|
|NTS-R-200|600|R/H|110-200|
|NTS-R-400|600|R/H|225-400|
|NTS-R-600|600|R/H|450-600|
## **Catalog Numbers**
|**Catalog Numbers (Pairs)**|**Catalog Numbers (Pairs)**|||
|---|---|---|---|
|**Voltages**||**Fuse**|**Equipment/Fuseblock**|
|**250V**|**600V**|**Amp Size Range**|**Amp Size**|
|NO.263-R|NO.663-R|1-30|60|
|NO.213-R|NO.216-R|1-30|100|
|NO.216-R|NO.616-R|35-60|100|
|NO.226-R|NO.626-R|35-60|200|
|NO.2621-R|NO.2621-R|70-100|200|
|NO.2641-R<br>NO.242-R<br>NO.2661-R<br>NO.2662-R<br>NO.2664-R**|NO.2641-R<br>NO.642-R<br>NO.2661-R<br>NO.2662-R<br>NO.2664-R**|70-100<br>110-200<br>70-100<br>110-200<br>225-400|400<br>400<br>600<br>600<br>600|
**Single reducer only (pair not required).
## **Fuse Reducers for Class H & K Fuses: NON, REN, NOS, RES UL Listed File E12853**
## **Catalog Numbers**
|**Catalog Numbers. (Pairs)**|**Catalog Numbers. (Pairs)**||**Equipment/**|
|---|---|---|---|
|**250V**|**600V**|**Fuse**|**Fuseblock**|
|**Reducer**|**Reducer**|**Amp Size Range**|**Amp Size**|
|NO.263|NO.663|1-30|60|
|NO.213|NO.216|1-30|100|
|NO.216|NO.616|35-60|100|
|NO.226|NO.626|35-60|200|
|NO.2621|NO.2621|70-100|200|
|NO.2641|NO.2641|70-100|400|
|NO.2642|NO.2642|110-200|400|
|No. 2661|No. 2661|70-100|600|
**Data Sheet: 1118**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**511**
a. a Compact modular i F * 4 7 - fuse holders VSS | he Big 'f scan
Finger-safe DIN-Rail mount fuse holders protect your electrical system & simplify installation
**512**
## **Bussmann Services & Application Guide**
## **Downtime Reduction, Workplace Safety & Code Compliance**
## **Services to Increase Your Productivity Through Protection**
## **Section Contents**
## **Bussmann Services**
**==> picture [245 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|514|
|Custom Products . . . . . . . . . . . . . . . . . . . . . . . . . 515|
|Application Guide|
|Fuse technology . . . . . . . . . . . . . . . . . . . . . . . . . . .516-522|
|Motor circuit branch circuit protection|. . . . . . . . . . . . . . .523|
|Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524-526|
|Out-of-stock substitution/upgrades|. . . . . . . . . . . . . . . .|526|
|Industrial & commercial fuse applications|. . . . . . . . . . .|527|
|Catalog number index|. . . . . . . . . . . . . . . . . 528-???|
|Sales support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .???|
**----- End of picture text -----**<br>
## **RED indicates NEW information**
**513**
**Services**
## **Testing**
## **Performance and Compliance Certification for Components and Assemblies**
The Bussmann Paul P. Gubany Center for High Power Technology at Bussmann is the electrical industry’s most comprehensive facility for testing and certifying electrical components and assemblies.
OEM customers make the Gubany Center their first choice in testing equipment such as:
- Drives, both AC and DC
- Circuit breakers
- Motor control centers
- Soft starters
- Fuses
- Power distribution panels
- Surge suppressors
- Cables
## **Wide Range of Capability**
Built to exceed the short circuit capacity of today’s high power electrical distribution systems, the Gubany Center performs:
- Ultra-high power testing from 200kA to 300kA at 600Vac, three-phase
- Medium power testing from 5kA to 200kA at 600Vac, single- and three-phase; to 100kA at 1450Vac single-phase; to 100kA at 1000Vdc
- Low power testing up to 5kA at 600Vac, single-phase.
Our technicians conduct tests to many global agency standards including:
- ANCE • ETL
- ANSI • IEC, and
- CE • Underwriters
- • CSA Laboratories
## **To Order:**
To find out more contact your local Bussmann representative, or visit us online at www.cooperbussmann.com/services.
|**Testing Catalog Numbers**|**Testing Catalog Numbers**|**Testing Catalog Numbers**|
|---|---|---|
|**Description**||**Catalog Number**|
|High Power Testing|Hourly Rate|CBSV-ES-TEHP|
|Medium Power Testing|Hourly Rate|CBSV-ES-TEMP|
|Low Power Testing|Hourly Rate|CBSV-ES-TELP|
Visit www.cooperbussmann.com
**514**
**Services**
## **Custom Products**
## **Creating the Right Answers to Unique or Demanding Needs**
When you wish to gain a competitive edge or improve your product's performance, have Busmann provide a custom product that can:
- Improve functionality and utility
- Fit unique design needs
- Reduce labor and component costs
## **Our Expertise Is Your Advantage**
For almost 100 years, Bussmann has designed and manufactured products that improve electrical safety and performance. Whether it's modifying an existing product or creating a new one, our experience effectively brings together the skills to design, prototype, test, manufacture and secure agency approvals to deliver a single component, sub-assembly or finished product.
Busmann can design and manufacture products that integrate:
- Fuses - with the right size and performance characteristics
- Fuse holders and blocks - with the requisite terminations, mounting options and safety features
**To Find Out More:**
If you need a custom solution to a product problem, submit a Request for Quotation to your local authorized Bussmann distributor or sales representative.
- Wire connection products - that make wiring simpler, safer and faster
- Molded products - that give the unique shape your product needs
- Power distribution products - that meet prevailing agency and Code requirements
## **In-House Testing**
All electrical performance testing of your custom products can be performed at the Bussmann Paul P. Gubany Center for High Power Technology, an ASTA and CSA accredited, and an ANCE Designated facility.
We're able to conduct electrical performance testing that replicates any power system to be encountered in any country, covering:
- Up to 300kA and 600Vac
- Up to 100kA and 1000Vdc
And our technicians conduct tests to many global agency standards including:
- ANCE
- ANSI
- CE
- CSA
- ETL
- IEC, and
- Underwriters Laboratories
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**515**
**Application Guide**
## **Fuse Technology**
## **Circuit Protection**
The following is a basic introduction to overcurrent protection and fuse technology. In depth information on the selection and application of overcurrent protective devices is available in the Bussmann publication “Selecting Protective Devices” (SPD). This publication is available free of charge as a PDF download at www.cooperbussmann.com/spd.
Electrical distribution systems are often quite complicated. They cannot be absolutely fail-safe. Circuits are subject to destructive overcurrents. Harsh environments, general deterioration, accidental damage, damage from natural causes, excessive expansion, and/or overloading of the electrical distribution system are factors which contribute to the occurrence of such overcurrents. Reliable protective devices prevent or minimize costly damage to transformers, conductors, motors, and the other many components and loads that make up the complete distribution system. Reliable circuit protection is essential to avoid the severe monetary losses which can result from power blackouts and prolonged downtime of facilities. It is the need for reliable protection, safety, and freedom from fire hazards that has made the fuse a widely used protective device.
## **Overcurrents**
An overcurrent is either an overload current or a short-circuit current. The overload current is an excessive current relative to normal operating current, but one which is confined to the normal conductive paths provided by the conductors and other components and loads of the distribution system. As the name implies, a short-circuit current is one which flows outside the normal conducting paths.
## **Overloads**
Overloads are most often between one and six times the normal current level. Usually, they are caused by harmless temporary surge currents that occur when motors are started-up or transformers are energized. Such overload currents, or transients, are normal occurrences. Since they are of brief duration, any temperature rise is trivial and has no harmful effect on the circuit components. (It is important that protective devices do not react to them.)
Continuous overloads can result from defective motors (such as worn motor bearings), overloaded equipment, or too many loads on one circuit. Such sustained overloads are destructive and must be cut off by protective devices before they damage the distribution system or system loads. However, since they are of relatively low magnitude compared to short-circuit currents, removal of the overload current within minutes will generally prevent equipment damage. A sustained overload current results in overheating of conductors and other components and will cause deterioration of insulation, which may eventually result in severe damage and short-circuits if not interrupted.
## **Short-Circuits**
Whereas overload currents occur at rather modest levels, the short-circuit or fault current can be many hundred times larger than the normal operating current. A high level fault may be
50,000A (or larger). If not cut off within a matter of a few thousandths of a second, damage and destruction can become rampant—there can be severe insulation damage, melting of conductors, vaporization of metal, ionization of gases, arcing, and fires. Simultaneously, high level short-circuit currents can develop huge magnetic-field stresses. The magnetic forces between bus bars and other conductors can be many hundreds of pounds per linear foot; even heavy bracing may not be adequate to keep them from being warped or distorted beyond repair.
## **Fuses**
The fuse is a reliable overcurrent protective device. A “fusible” link or links encapsulated in a tube and connected to contact terminals comprise the fundamental elements of the basic fuse. Electrical resistance of the link is so low that it simply acts as a conductor. However, when destructive currents occur, the link very quickly melts and opens the circuit to protect conductors, and other circuit components and loads. Fuse characteristics are stable. Fuses do not require periodic maintenance or testing. Fuses have three unique performance characteristics:
_1. Modern fuses have an extremely “high interrupting rating”—can withstand very high fault currents without rupturing._
_2. Properly applied, fuses prevent “blackouts.” Only the fuse nearest a fault opens without upstream fuses (feeders or mains) being affected—fuses thus provide “selective coordination.” (These terms are precisely defined in subsequent pages.)_
_3. Fuses provide optimum component protection by keeping fault currents to a low value…They are said to be “current limiting.”_
## **Voltage Rating**
The voltage rating of a fuse must be at least equal to or greater than the circuit voltage. It can be higher but never lower. For instance, a 600V fuse can be used in a 208V circuit.
The voltage rating of a fuse is a function of its capability to open a circuit under an overcurrent condition. Specifically, the voltage rating determines the ability of the fuse to suppress the internal arcing that occurs after a fuse link melts and an arc is produced. If a fuse is used with a voltage rating lower than the circuit voltage, arc suppression will be impaired and, under some fault current conditions, the fuse may not clear the overcurrent safely. Special consideration is necessary for semiconductor fuse and medium voltage fuse applications, where a fuse of a certain voltage rating is used on a lower voltage circuit.
## **Amp Rating**
Every fuse has a specific amp rating. In selecting the amp rating of a fuse, consideration must be given to the type of load and code requirements. The amp rating of a fuse normally should not exceed the current carrying capacity of the circuit. For instance, a continuous load current of 16 amperes typically requires a conductor rated to carry 20A and a 20A fuse is the largest that should be used. However, there are some specific circumstances in which the amp rating is permitted to be greater than the current carrying capacity of the circuit.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**516**
**Application Guide**
## **Fuse Technology**
A typical example is the motor circuit; dual-element fuses generally are permitted to be sized up to 175% and non-timedelay fuses up to 300% of the motor full-load amps. As a rule, the amp rating of a fuse and switch combination should be selected at 125% of the continuous load current (this usually corresponds to the circuit capacity, which is also selected at 125% of the load current). There are exceptions, such as when the fuse-switch combination is approved for continuous operation in an assembly at 100% of its rating.
## **Interrupting Rating**
A protective device must be able to withstand the destructive energy of short-circuit currents. If a fault current exceeds the capability of the protective device, the device may actually rupture, causing additional damage. Thus, it is important when applying a fuse or circuit breaker to use one which can sustain the largest potential short-circuit currents. The rating which defines the capacity of a protective device to maintain its integrity when reacting to fault currents is termed its “interrupting rating”. The interrupting rating of most branch-circuit, molded case, circuit breakers typically used in residential service entrance panels is 10,000A. Larger, more expensive circuit breakers may have interrupting ratings of 14,000A or higher. In contrast, most modern, current-limiting fuses have an interrupting rating of 200,000 or 300,000A and are commonly used to protect the lower rated circuit breakers. The National Electrical Code, Section 110-9, and §OSHA 29 CFR 1910.303(b)(4) require equipment intended to break current at fault levels to have an interrupting rating sufficient for the current that must be interrupted.
## **Selective Coordination – Prevention of Blackouts**
Coordination is isolation of an overloaded or faulted circuit by the opening of only the nearest upstream protective device for a specific overcurrent value. When only the nearest upstream protective device of an overloaded or faulted circuit opens and larger upstream fuses remain closed for the full range of overcurrents on a system, the protective devices are “selectively” coordinated (they discriminate). Selective coordination of protective devices prevents unnecessary system power outages or blackouts caused by overcurrent conditions.
**==> picture [252 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
LPS-RK<br>LPS-RK 200SP<br>KRP-C 600SP<br>1200SP<br>2:1 (or more)<br>2:1 (or more)<br>**----- End of picture text -----**<br>
**This diagram shows the minimum ratios of amp ratings of Low-Peak Yellow fuses that are required to provide “selective coordination” (discrimination) of upstream and downstream fuses.**
## **Current Limitation – Component Protection**
**==> picture [201 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
Areas within waveform<br>loops represent destructive<br>Not current-limiting energy impressed upon<br>circuit components<br>Normal<br>load current<br>Circuit breaker trips<br>and opens short-circuit<br>Initiation of in about 1 cycle<br>short-circuit<br>current<br>**----- End of picture text -----**<br>
A non-current-limiting protective device, by permitting a shortcircuit current to build up to its full value, can let an immense amount of destructive short-circuit heat energy through before opening the circuit.
**==> picture [176 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current-limiting<br>Fuse opens and clearsr<br>short-circuit in lessr<br>than ⁄Ω™ cycle<br>**----- End of picture text -----**<br>
A current-limiting fuse has such a high speed of response that it cuts off a short-circuit long before it can build up to its full peak value, when the fault current is within the current-limiting range of a fuse.
If a protective device cuts off a short-circuit current in less than one-half cycle, before it reaches its total available (and highly destructive) value, the device is a “current-limiting” device. Most modern fuses are current-limiting. They restrict fault currents to such low values that a high degree of protection is given to circuit components against even very high short-circuit currents. They permit breakers with lower interrupting ratings to be used when series rated. They can reduce bracing of bus structures. They minimize the need of other components to have high short-circuit current “withstand” ratings. If not limited, short-circuit currents can reach levels of 30,000 or 40,000A or higher in the first half cycle (.008 seconds, 60Hz) after the start of a short-circuit. The heat that can be produced in circuit components by the immense energy of short-circuit currents can cause severe insulation damage or even explosion. At the same time, huge magnetic forces developed between conductors can crack insulators and distort and destroy bracing structures. Thus, it is important that a protective device limit fault currents before they reach their full potential level.
It is a simple matter to selectively coordinate modern currentlimiting fuses. By maintaining a minimum ratio of fuse-amp ratings between an upstream and downstream fuse, selective coordination is assured.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**517**
**Application Guide**
## **Fuse Technology**
## **Operating Principles of Bussmann Fuses**
The principles of operation of the modern, current-limiting fuses are covered in the following paragraphs.
## **Non-Time-Delay Fuses**
The basic component of a fuse is the link. Depending upon the amp rating of the fuse, the single-element fuse may have one or more links. They are electrically connected to the end blades (or ferrules) (see Figure 1) and enclosed in a tube or cartridge surrounded by an arc quenching filler material. Bussmann Limitron[™] and T-Tron[™] fuses are both single-element fuses.
Under normal operation, when the fuse is operating at or near its amp rating, it simply functions as a conductor. However, as illustrated in Figure 2, if an overload current occurs and persists for more than a short interval of time, the temperature of the link eventually reaches a level which causes a restricted segment of the link to melt. As a result, a gap is formed and an electric arc established. However, as the arc causes the link metal to burn back, the gap becomes progressively larger. Electrical resistance of the arc quickly reaches such a high level that the arc cannot be sustained and is extinguished. The fuse will have then completely cut off all current flow in the circuit. Suppression or quenching of the arc is accelerated by the filler material. (See Figure 3.)
Single-element fuses of present day design have a very high speed of response to overcurrents. They provide excellent short-circuit component protection. However, temporary, harmless overloads or surge currents may cause nuisance openings unless these fuses are oversized. They are best used, therefore, in circuits not subject to heavy transient surge currents and the temporary over-load of circuits with inductive loads such as motors, transformers, solenoids, etc. Because single-element, fast-acting fuses such as Limitron and T-Tron fuses have a high speed of response to short-circuit currents, they are particularly suited for the series rating protection of circuit breakers with low interrupting ratings.
Whereas an overload current normally falls between one and six times normal current, short-circuit currents are quite high. The fuse may be subjected to short-circuit currents of 30,000 or 40kA or higher. Response of current limiting fuses to such currents is extremely fast. The restricted sections of the fuse link will simultaneously melt (within a matter of two or threethousandths of a second in the event of a high-level fault current).
The high total resistance of the multiple arcs, together with the quenching effects of the filler particles, results in rapid arc suppression and clearing of the circuit. (Refer to Figures 4 & 5) Short-circuit current is cut off in less than a half-cycle, long before the short-circuit current can reach its full value (fuse operating in its current limiting range).
**Figure 1. Cutaway view of typical single-element fuse.**
**Figure 2. Under sustained overload, a section of the link melts and an arc is established.**
**Figure 3. The “open” single-element fuse after opening a circuit overload.**
**Figure 4. When subjected to a short-circuit current, several sections of the fuse link melt almost instantly.**
**Figure 5. The “open” single-element fuse after opening a short circuit.**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**518**
**Application Guide**
## **Fuse Technology**
## **Bussmann Dual-Element Fuses**
There are many advantages to using these fuses. Unlike single-element fuses, the Bussmann dual-element, time-delay fuses can be sized closer to provide both high performance short-circuit protection and reliable overload protection in circuits subject to temporary overloads and surge currents. For ac motor loads, a single-element fuse may need to be sized at 300% of an a.c. motor current in order to hold the starting current. However, dual-element, time delay fuses can be sized much closer to motor loads. For instance, it is generally possible to size Fusetron Dual-Element Fuses, FRS-R and FRN-R and Low-Peak[™] Dual-Element Fuses, LPS-RK_SP and LPN-RK_SP, at 125% and 130% of motor full load current, respectively. Generally, the Low-Peak Dual-Element Fuses, LPJ_SP, and CUBEFuse[™] , TCF, can be sized at 150 to 175% of motor full load amps. This closer fuse sizing may provide many advantages such as: (1) smaller fuse and block, holder or disconnect amp rating and physical size, (2) lower cost due to lower amp rated devices and possibly smaller required panel space, (3) better short-circuit protection – less short-circuit current let-through energy, and (4) potential reduction in the arc-flash hazard.
**==> picture [134 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Insulated end-caps to help prevent<br>accidental contact with live parts.<br>**----- End of picture text -----**<br>
**==> picture [54 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Filler material<br>**----- End of picture text -----**<br>
**Figure 6.** This is the LPS-RK100SP, a 100A, 600V Low-Peak, Class RK1, Dual-Element Fuse that has excellent time-delay, excellent current-limitation and a 300kA interrupting rating. Artistic liberty is taken to illustrate the internal portion of this fuse. The real fuse has a non-transparent tube and special small granular, arc-quenching material completely filling the internal space.
**==> picture [278 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
Small volume of metal to vaporize<br>Short-circuit element<br>‘ . e a =<br>ish - s 5<br>Overload element<br>**----- End of picture text -----**<br>
**Figure 9.** Short-circuit operation: Modern fuses are designed with minimum metal in the restricted portions which greatly enhance their ability to have excellent current-limiting characteristics – minimizing the short circuit let-through current. A short-circuit current causes the restricted portions of the short-circuit element to vaporize and arcing commences. The arcs burn back the element at the points of the arcing. Longer arcs result, which assist in reducing the current. Also, the special arc quenching filler material contributes to extinguishing the arcing current. Modern fuses have many restricted portions, which results in many small arclets – all working together to force the current to zero.
**Figure 7.** The true dual-element fuse has distinct and separate overload element and shortcircuit element.
**==> picture [84 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
NO Before a<br>Spring<br>~<br>NL After __-<br>**----- End of picture text -----**<br>
**==> picture [94 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Filler quenches the arcs<br>**----- End of picture text -----**<br>
**Figure 10.** Short-circuit operation: The special small granular, arc-quenching material plays an important part in the interruption process. The filler assists in quenching the arcs; the filler material absorbs the thermal energy of the arcs, fuses together and creates an insulating barrier. This process helps in forcing the current to zero. Modern current-limiting fuses, under shortcircuit conditions, can force the current to zero and complete the interruption within a few thousandths of a second.
**Figure 8.** Overload operation: Under sustained overload conditions, the trigger spring fractures the calibrated fusing alloy and releases the “connector”. The insets represent a model of the overload element before and after. The calibrated fusing alloy connecting the short-circuit element to the overload element fractures at a specific temperature due to a persistent overload current. The coiled spring pushes the connector from the short-circuit element and the circuit is interrupted.
When the short-circuit current is in the current-limiting range of a fuse, it is not possible for the full available short-circuit current to flow through the fuse – it’s a matter of physics. The small restricted portions of the short-circuit element quickly vaporize and the filler material assists in forcing the current to zero. The fuse is able to “limit” the short-circuit current.
Overcurrent protection must be reliable and sure. Whether it is the first day of the electrical system or thirty or more years later, it is important that overcurrent protective devices perform under overload or short-circuit conditions as intended. Modern current-limiting fuses operate by very simple, reliable principles.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**519**
**Application Guide**
## **Fuse Technology**
## **Fuse Time-Current Curves**
Below is a rerating chart for single element fuses or non dual element fuses.
When a low level overcurrent occurs, a long interval of time will be required for a fuse to open (melt) and clear the fault. On the other hand, if the overcurrent is large, the fuse will open very quickly. The opening time is a function of the magnitude of the level of overcurrent. Overcurrent levels and the corresponding intervals of opening times are logarithmically plotted in graph form as shown to the right. Levels of overcurrent are scaled on the horizontal axis; time intervals on the vertical axis. The curve is thus called a “time-current” curve.
This particular plot reflects the characteristics of a 200A, 250V, Low-Peak[™] dual-element fuse. Note that at the 1,000A overload level, the time interval which is required for the fuse to open is 10 seconds. Yet, at approximately the 2,200A overcurrent level, the opening (melt) time of a fuse is only 0.01 seconds. It is apparent that the time intervals become shorter as the overcurrent levels become larger. This relationship is termed an inverse time-to-current characteristic. Time-current curves are published or are available on most commonly used fuses showing “minimum melt,” “average melt” and/or “total clear” characteristics. Although upstream and downstream fuses are easily coordinated by adhering to simple amp ratios, these time-current curves permit close or critical analysis of coordination.
## **Better Motor Protection in Elevated Ambients**
The derating of dual-element fuses based on increased ambient temperatures closely parallels the derating curve of motors in elevated ambient. This unique feature allows for optimum protection of motors, even in high temperatures.
Affect of ambient temperature on operating characteristics of Fusetron and Low-Peak dual-element fuses.
**==> picture [252 x 188] intentionally omitted <==**
**----- Start of picture text -----**<br>
150<br>140<br>130 Affect on Carrying<br>120 Capacity Rating<br>110<br>100<br>90<br>80<br>Affect on<br>70 Opening Time<br>60<br>50<br>40<br>30<br>–76 ° F –40 ° F –4 ° F –32 ° F 68 ° F 104 ° F 140 ° F 176 ° F 212 ° F<br>(–60 ° C) (–40 ° C) (–20 ° C) (0 ° C) (20 ° C) (40 ° C) (60 ° C) (80 ° C) (100 ° C)<br>AMBIENT<br>OPENING TIME<br>PERCENT OF RATING OR<br>**----- End of picture text -----**<br>
_Ambient affect chart for non-dual-element fuses._
**==> picture [251 x 410] intentionally omitted <==**
**----- Start of picture text -----**<br>
400<br>300<br>200<br>LOW-PEAK<br>LPN-RK200 SP (RK1)<br>100<br>80<br>60<br>40<br>30<br>20<br>10<br>8<br>6<br>4<br>3<br>2<br>1<br>.8<br>.6<br>.4<br>.3<br>.2<br>.1<br>.08<br>.06<br>.04<br>.03<br>.02<br>.01<br>CURRENT IN AMPS<br>TIME IN SECONDS<br>100 200 300 400 600 800 1,000 2,000 3,000 4,000 6,000 8,000 10,000<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**520**
**Application Guide**
## **Fuse Technology**
## **Better Protection Against Motor Single Phasing**
When secondary single-phasing occurs, the current in the remaining phases increases to approximately 200% rated full load current. (Theoretically 173%, but change in efficiency and power factor make it about 200%.) When primary singlephasing occurs, unbalanced voltages occur on the motor circuit causing currents to rise to 115%, and 230% of normal running currents in delta-wye systems.
No overcurrent protective device sized only for motor branch circuit short-circuit, ground fault protection will provide singlephasing protection for 3-phase motors. Single-phasing causes are numerous including the utility system that supplies the service losing a phase. Single-phasing is not a serious concern for 3-phase motors when properly protected by three properly sized and calibrated overload protective devices. Many solid state motor controllers will sense and cause the motor controller to open for serious unbalanced voltage situations caused by single-phasing. FRN-R, FRS-R, LPN-R_SP and LPS-R_SP dual-element fuses sized for motor running overload protection will help to protect motors against the possible damages of single-phasing. In addition, additional unbalanced voltage protection can be incorporated into motor protection schemes, if desired. For more information refer to the Cooper Bussmann Selecting Protective Devices publication, section Voltage Unbalance & Single-Phasing.
## **Classes of Fuses**
Safety is the industry mandate. However, proper selection, overall functional performance and reliability of a product are factors which are not within the basic scope of listing agency activities. In order to develop its safety test procedures, listing agencies develop basic performance and physical specifications or standards for a product. In the case of fuses, these standards have culminated in the establishment of distinct classes of low-voltage (600V or less) fuses; Classes RK1, RK5, G, L, T, J, H and CC being the more important.
The fact that a particular type of fuse has, for instance, a classification of RK1, does not signify that it has the identical function or performance characteristics as other RK1 fuses. In fact, the Limitron[™] non-time-delay fuse and the Low-Peak dual-element, time-delay fuse are both classified as RK1. Substantial differences in these two RK1 fuses usually requires considerable difference in sizing. Dimensional specifications of each class of fuse does serve as a uniform standard.
older type Class H, ONE-TIME and RENEWABLE fuses from being installed. The use of Class R fuse holders is thus an important safeguard. The application of Class R fuses in such equipment as disconnect switches permits the equipment to have a high interrupting rating. NEC[®] 110-9 and §OSHA 29 CFR 1910.303(b)(4) require that protective devices have adequate capacity to interrupt short-circuit currents. Article 240-60(b) requires fuse holders for current-limiting fuses to reject non-current-limiting type fuses. In the above illustration, a grooved ring in one ferrule provides the rejection feature of the Class R fuse in contrast to the lower interrupting rating, non-rejection type.
## **Branch-Circuit Listed Fuses**
Branch-circuit listed fuses are designed to prevent the installation of fuses that cannot provide a comparable level of protection to equipment.
The characteristics of Branch-circuit fuses are:
1. They must have a minimum interrupting rating of 10kA
2. They must have a minimum voltage rating of 125V.
3. They must be size rejecting such that a fuse of a lower voltage rating cannot be installed in the circuit.
4. They must be size rejecting such that a fuse with a current rating higher than the fuse holder rating cannot be installed.
## **Class R Fuses**
Class R (“R” for rejection) fuses are high performance,[1] ⁄10 to 600A units, 250V and 600V, having a high degree of current limitation and a short-circuit interrupting rating of 200kA or 300kA (RMS Sym.). Bussmann Class R fuses include Class RK1 Low-Peak[™] and Limitron[™] fuses, and RK5 Fusetron fuses. They have replaced the K1 Low-Peak and Limitron fuses and K5 Fusetron fuses. These fuses are identical, with the exception of a modification in the mounting configuration called a “rejection feature.” This feature permits Class R fuses to be mounted in rejection type fuseclips. “R” type fuseclips prevent
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**521**
**Application Guide**
## **Fuse Technology**
## **Supplementary Overcurrent Protective Devices for use in Motor Control Circuits**
## **Branch Circuit vs. Supplemental Overcurrent**
## **Protective Devices**
Branch circuit overcurrent protective devices (OCPD) can be used everywhere OCPD are used, from protection of motors and motor circuits and group motor circuits, to protection of distribution and utilization equipment. Supplemental OCPD can only be used where proper protection is already being provided by a branch circuit device, by exception [i.e., 430.72(A)], or if protection is not required. Supplemental OCPD can often be used to protect motor control circuits but they cannot be used to protect motors or motor circuits. A very common misapplication is the use of a supplementary overcurrent protective device such as a UL 1077 mechanical overcurrent device for motor branch circuit short-circuit and ground fault protection. Supplementary OCPDs are incomplete in testing compared to devices that are evaluated for branch circuit protection. THIS IS A SERIOUS MISAPPLICATION AND SAFETY CONCERN!! Caution should be taken to assure that the proper overcurrent protective device is being used for the application at hand. Below is a description of popular supplementary overcurrent protective devices.
## **Reliability and Maintenance of Overcurrent Protective Devices**
Whether the first day of the electrical system or years later, it is important that overcurrent protective devices perform under overload and fault conditions as intended.
Modern current-limiting fuses operate by very simple, reliable principles. Fuses do not have to be maintained. By their inherent design, fuses do not have elements or mechanisms to calibrate, adjust or lubricate. If and when fuses are called upon to open on an overcurrent, installing the same type and ampere rated fuses provides the circuit with new factorycalibrated protection. The original design integrity can be maintained throughout the life of the electrical system. One last point on fuse systems; the terminations, clips and disconnects should be maintained as necessary.
Most supplemental overcurrent protective devices have very low interrupting ratings. Just as any other overcurrent protective device, supplemental OCPDs must have an interrupting rating equal to or greater than the available short-circuit current.
## **Supplemental fuses as listed or recognized to the UL/CSA/ANCE Trinational 248-14 Standard**
These are fuses that can have many voltages and interrupting ratings within the same case size. Examples of supplemental fuses are[13] ⁄32'' X 1[1] ⁄2'', 5 x 20mm, and[1] ⁄4'' x 1[1] ⁄4'' fuses. Interrupting ratings range from 35 to 100kA.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**522**
**Application Guide**
## **Motor Circuit Branch Circuit Protection**
## **Motor Circuits – Choice of Overcurrent Protection**
Motor circuits have unique characteristics and several functions, such as short-circuit protection, overload protection and automatic/ remote start/stop, that may be required. Sometimes the comment is made that users prefer circuit breakers because they can be reset. Let’s examine the choice of either circuit breakers or current- limiting fuses for motor branch circuit protection.
In the case to be examined, fuses and circuit breakers (includes magnetic only circuit breakers which are called MCPs or motor circuit protectors) are sized with the intent to provide only short-circuit and ground fault protection for the motor branch circuit protection per 430.52. Other means, such as overload relays, provide the motor overload protection. Typical thermal magnetic circuit breakers can only be sized for motor branch circuit protection (typically 200% - 250% of motor current) because if they are sized closer, the motor starting current trips the circuit breaker’s instantaneous mechanism. Magnetic only circuit breakers (MCPs) are intentionally not provided with overload capability; they only operate on short-circuit currents. There are some fuses such as the FRS-R and LPS-RK fuses that can be sized close enough for motor running overload protection or backup motor running protection. But for the discussion in this section, assume current-limiting fuses are sized only for motor short-circuit and ground fault protection.
It is important to note that in this protection level being discussed, a circuit breaker or fuses should only open if there is a fault on the motor circuit. A separate overload protective device, such as an overload relays, provides motor overload protection per 430.32. Here are some important considerations:
## 1. OSHA regulation 1910.334(b)(2) Use of Equipment states:
- _Reclosing circuits after protective device operation. After a circuit is deenergized by a circuit protective device, the circuit may not be manually reenergized until it has been determined that the equipment and circuit can be safely energized. The repetitive manual reclosing of circuit breakers or reenergizing circuits through replaced fuses is prohibited. NOTE: When it can be determined from the design of the circuit and the over-current devices involved that the automatic operation of a device was caused by an overload rather than a fault condition, no examination of the circuit or connected equipment is needed before the circuit is reenergized._
_So the speed of reclosing a circuit breaker after a fault is not an advantage. The law requires that if the condition is a fault (that is the only reason the circuit breaker or fuses should open on a motor circuit), then the fault must be corrected prior to replacing fuses or resetting the circuit breaker._
_2. The typical level of short-circuit protection for the motor starter provided by circuit breakers and MCPs is referred to as Type 1. This is because most circuit breakers are not current-limiting. So, for a loadside fault, the starter may sustain significant damage such as severe welding of contacts and rupturing of the heater elements. Or the heater/overload relay system may lose calibration. This is an acceptable level of performance per UL 508, which is the product standard for motor starters. Current-limiting fuses can be selected that can provide Type 2 “No Damage” short-circuit protection for motor starters._
_Consequently, with circuit breaker protection, after a fault condition,_
_significant downtime and cost may be incurred in repairing or replacing the starter. With properly selected fuses for Type 2 protection, after the fault is repaired, only new fuses need to be inserted in the circuit; the starter does not have to be repaired or replaced._
_3. Circuit breakers must be periodically tested to verify they mechanical operate and electrically tested to verify they still are properly calibrated within specification. The circuit breaker manufacturers recommend this. Typically circuit breakers should be mechanically operated at least every year and electrically tested every 1 to 5 years, depending on the service conditions. Modern current-limiting fuses do not have to be maintained or electrically tested to verify they still will operate as intended. The terminations of both circuit breakers and fusible devices need to be periodically checked and maintained to prevent thermal damage. Plus fuse clips should be periodically inspected and if necessary maintained._
_4. After a circuit breaker interrupts a fault, it may not be suitable for further service. UL 489, the product standard for molded case circuit breakers, only requires a circuit breaker to interrupt two short-circuit currents at its interrupting rating. Circuit breakers that are rated 100 amps or less do not have to operate after only one short-circuit operation under “bus bar” short-circuit conditions. If the fault current is high, circuit breaker manufacturers recommend that a circuit breaker should receive a thorough inspection with replacement, if necessary. How does one know a circuit breaker’s service history or what level of fault current that a circuit breaker interrupts? With modern current-limiting fuses, if the fuse interrupts a fault, new factory calibrated fuses are installed in the circuit. The original level of superior short-circuit protection can be there for the life of the motor circuit._
_5. After a fault, the electrician has to walk back to the storeroom to get new fuses; that is if spare fuses are not stored adjacent to the equipment. This does require some additional down time. However, if fuses opened under fault conditions, there is a fault condition that must be remedied. The electrician probably will be going back to the storeroom anyway for parts to repair the fault. If properly selected current-limiting fuses are used in the original circuit, the starter will not sustain any significant damage or loss of overload calibration._
With circuit breaker protection on motor circuits, after a fault condition, it may be necessary to repair or replace the starter, so a trip to the storeroom may be necessary. And if the starter is not significantly damaged, it may still need to be tested to insure the let-through energy by the circuit breaker has not caused the loss of starter overload calibration. Also, the circuit breaker needs to be evaluated for suitability before placing it back into service. Who is qualified for that evaluation? How much time will that take?
In summary, resettability is not an important feature for motor branch circuit (short-circuit) protection and resettability of the branch circuit protective device is not a benefit for motor circuits. As a matter of fact, resettability of the motor branch circuit overcurrent protective device may encourage an unsafe practice. The function of motor branch circuit protection is fault protection: short-circuit and ground fault protection. Faults do not occur on a regular basis. But when a fault does occur, it is important to have the very best protection. The best motor branch circuit protection can be judged by (1) reliability - its ability to retain its calibration and speed of operation over its lifetime, (2) current-limiting protection - its ability to provide Type 2 “No Damage” protection to the motor starter, and (3) safety - its ability to meet a facility’s safety needs. Modern current-limiting fuses are superior to circuit breakers for motor branch circuit protection.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**523**
**Application Guide**
## **Glossary**
## **Ampere (Amp)**
The measurement of intensity of rate of flow of electrons in an electric circuit. An ampere (amp) is the amount of current that will flow through a resistance of one ohm under a pressure of one volt. Ampere is often abbreviated as “A.”
## **Amp Rating**
The current-carrying capacity of a fuse. When a fuse is subjected to a current above its amp rating, it will open the circuit after a predetermined period of time.
## **Amp Squared Seconds, l[2] t**
The measure of heat energy developed within a circuit during the fuse’s clearing. It can be expressed as “melting l[2] t”, “arcing l[2] t” or the sum of them as “Clearing l[2] t”. “l” stands for effective let-through current (RMS), which is squared, and “t” stands for time of opening, in seconds.
## **Arcing I[2] t**
Value of the I[2] t during the arcing time under specified conditions.
## **Arcing Time**
The amount of time from the instant the fuse link has melted until the overcurrent is interrupted, or cleared.
## **Breaking Capacity**
(See Interrupting Rating)
## **Cartridge Fuse**
A fuse consisting of a current responsive element inside a fuse tube with terminals on both ends.
## **Class CC Fuses**
600V, 200kA interrupting rating, branch circuit fuses with overall dimensions of 13⁄32” x 11⁄2”. Their design incorporates a rejection feature that allows them to be inserted into rejection fuse holders and fuse blocks that reject all lower voltage, lower interrupting rat ing[13] ⁄32” x 1[1] ⁄2” fuses. They are available from[1] ⁄10A through 30A.
## **Class G Fuses**
480V, 100kA interrupting rating branch circuit fuses that are size rejecting to eliminate overfusing. The fuse diameter ˝ is[13] ⁄32˝ while the length varies from 1[5] ⁄16 to 2[1] ⁄4˝. These are available in ratings from 1A through 60A.
## **Class H Fuses**
250V and 600V, 10kA interrupting rating branch circuit fuses that may be renewable or non-renewable. These are available in amp ratings of 1A through 600A.
## **Class J Fuses**
These fuses are rated to interrupt a minimum of 200kA AC. They are labeled as “Current-Limiting,” are rated for 600Vac, and are not interchangeable with other classes.
## **Class K Fuses**
These are fuses listed as K-1, K-5, or K-9 fuses. Each subclass has designated I[2] t and lp maximums. These are dimensionally the same as Class H fuses, and they can have interrupting ratings of 50kA, 100kA, or 200kA. These fuses are current-limiting. However, they are not marked “current-limiting” on their label since they do not have a rejection feature.
## **Class L Fuses**
These fuses are rated for 601 through 6000A, and are rated to interrupt a minimum of 200kA AC. They are labeled “Current-Limiting” and are rated for 600Vac. They are intended to be bolted into their mountings and are not normally used in clips. Some Class L fuses have designed in time-delay features for all purpose use.
## **Class R Fuses**
These are high performance fuses rated 1 ⁄10-600A in 250V and 600V ratings. All are marked “Current Limiting” on their label and all have a minimum of 200kA interrupting rating. They have identical outline dimensions with the Class H fuses but have a rejection feature which prevents the user from mounting a fuse of lesser capabilities (lower interrupting capacity) when used with special Class R Clips. Class R fuses will fit into either rejection or non-rejection clips.
## **Class T Fuses**
An industry class of fuses in 300V and 600V ratings from 1A through 1200A. They are physically very small and can be applied where space is at a premium. They are fast-acting fuses with an interrupting rating of 200kA RMS.
## **Classes of Fuses**
The industry has developed basic physical specifications and electrical performance requirements for fuses with voltage ratings of 600V or less. These are known as standards. If a type of fuse meets the requirements of a standard, it can fall into that class. Typical classes are K, RK1, RK5, G, L, H, T, CC, and J.
## **Clearing Time**
The total time between the beginning of the overcurrent and the final opening of the circuit at rated voltage by an overcurrent protective device. Clearing time is the total of the melting time and the arcing time.
## **Current Limitation**
A fuse operation relating to short circuits only. When a fuse operates in its current-limiting range, it will clear a short circuit in less than[1] ⁄2 cycle. Also, it will limit the instantaneous peak let-through current to a value substantially less than that obtainable in the same circuit if that fuse were replaced with a solid conductor of equal impedance.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**524**
**Application Guide**
## **Glossary**
## **Dual Element Fuse**
Fuse with a special design that utilizes two individual elements in series inside the fuse tube. One element, the spring actuated trigger assembly, operates on overloads up to 5-6 times the fuse current rating. The other element, the short circuit section, operates on short circuits up to their interrupting rating.
## **Electrical Load**
That part of the electrical system which actually uses the energy or does the work required.
## **Fast-Acting Fuse**
A fuse which opens on overload and short circuits very quickly. This type of fuse is not designed to withstand temporary overload currents associated with some electrical loads.
## **Fuse**
An overcurrent protective device with a fusible link that operates and opens the circuit on an overcurrent condition.
## **High Speed Fuses**
Fuses with no intentional time-delay in the overload range and designed to open as quickly as possible in the short-circuit range. These fuses are often used to protect solid-state devices.
## **Inductive Load**
An electrical load which pulls a large amount of current—an inrush current— when first energized. After a few cycles or seconds the current “settles down” to the full-load running current.
## **Interrupting Capacity**
(See Interrupting Rating)
## **Interrupting Rating — IR (Breaking Capacity)**
The rating which defines a fuse’s ability to _safely_ interrupt and clear short circuits. This rating is much greater than the ampere rating of a fuse. The NEC[®] defines Interrupting Rating as “The highest current at rated voltage that an overcurrent protective device is intended to interrupt under standard test conditions.”
## **Melting I[2] t**
Value of the I[2] t during the melting time of the fuse link under specified conditions.
## **Melting Time**
The amount of time required to melt the fuse link during a specified overcurrent. (See Arcing Time and Clearing Time.)
## **“NEC[®] ” Dimensions**
These are dimensions once referenced in the National Electrical Code. They are common to Class H and K fuses and provide interchangeability between manufacturers for fuses and fusible equipment of given ampere and voltage ratings.
## **Ohm**
The unit of measure for electric resistance. An ohm is the amount of resistance that will allow one ampere to flow under a pressure of one volt.
## **Ohm’s Law**
The relationship between voltage, current, and resistance, expressed by the equation E = IR, where E is the voltage in volts, I is the current in amps, and R is the resistance in ohms.
## **One Time Fuses**
Generic term used to describe a Class H non-renewable cartridge fuse, with a single element.
## **Overcurrent**
A condition which exists on an electrical circuit when the normal load current is exceeded. Overcurrents take on two separate characteristics—overloads and short-circuits.
## **Overload**
Can be classified as an overcurrent which exceeds the normal full load current of a circuit. Also characteristic of this type of overcurrent is that it does not leave the normal current carrying path of the circuit—that is, it flows from the source, through the conductors, through the load, back through the conductors, to the source again.
## **Peak Let-Through Current, lp**
The instantaneous value of peak current let-through by a current-limiting fuse, when it operates in its current-limiting range.
## **Renewable Fuse (600V & below)**
A fuse in which the element, typically a zinc link, may be replaced after the fuse has opened, and then reused. Renewable fuses are made to Class H standards.
## **Resistive Load**
An electrical load which is characteristic of not having any significant inrush current. When a resistive load is energized, the current rises instantly to its steady-state value, without first rising to a higher value.
## **RMS Current**
The RMS (root-mean-square) value of any periodic current is equal to the value of the direct current which, flowing through a resistance, produces the same heating effect in the resistance as the periodic current does.
## **SCCR**
See Short-Circuit Current Rating
## **Semiconductor Fuses**
Fuses used to protect solid-state devices. See “High Speed Fuses.”
## **Short-Circuit**
Can be classified as an overcurrent which exceeds the normal full load current of a circuit by a factor many times (tens, hundreds or thousands greater). Also characteristic of this type of overcurrent is that it leaves the normal current carrying path of the circuit—it takes a “short cut” around the load and back to the source.
## **Short-Circuit Current Rating (SCCR)**
The maximum short-circuit current an electrical component can sustain without the occurrence of excessive damage when protected with an overcurrent protective device.
## **Short-Circuit Withstand Rating**
Same definition as short-circuit current rating.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**525**
**Application Guide**
## **Glossary**
## **Single-Phasing**
That condition which occurs when onephase of a three-phase system opens, either in a low voltage (secondary) or high voltage (primary) distribution system. Primary or secondary singlephasing can be caused by any number of events. This condition results in unbalanced currents in polyphase motors and unless protective measures are taken, causes overheating and failure.
## **Threshold Current**
The symmetrical RMS available current at the threshold of the current-limiting range, where the fuse becomes current-limiting when tested to the industry standard. This value can be read off of a peak let-through chart where the fuse curve intersects the A-B line. A threshold ratio is the relationship of the threshold current to the fuse’s continuous current rating.
## **Time-Delay Fuse**
A fuse with a built-in delay that allows temporary and harmless inrush currents to pass without opening, but is so designed to open on sustained overloads and short circuits.
## **Total Clearing I[2] t**
## **Out-of-Stock Substitution/Upgrades**
**==> picture [253 x 311] intentionally omitted <==**
**----- Start of picture text -----**<br>
Bussmann # Upgrade # Description Data Sheet #<br>AGC-(AMP) ABC-(AMP) FAST-ACTING, [1] ⁄4” X 1 [1] ⁄4” FUSE 2001<br>AGC-V-(AMP) ABC-V-(AMP) FAST-ACTING, [1] ⁄4” X 1 [1] ⁄4” FUSE WITH LEADS 2001<br>AGU-(AMP) LP-CC-(AMP) FAST-ACTING, [13] ⁄32” X 1 [1] ⁄2” FUSE 2008<br>BAF-(AMP) LP-CC-(AMP) FAST-ACTING, [13] ⁄32” X 1 [1] ⁄2” FUSE 2011<br>BAN-(AMP) LP-CC-(AMP) FAST-ACTING, [13] ⁄32” X 1 [1] ⁄2” FUSE 2046<br>DCM-(AMP) PVM-(AMP) SOLAR USE - FAST-ACTING, [13] ⁄32” X 1 [1] ⁄2” FUSE 2153<br>DCM-(AMP) KLM-(AMP) INDUSTRIAL - FAST-ACTING, [13] ⁄32” X 1 [1] ⁄2” FUSE 2020<br>DLS-(AMP) ECNR-(AMP) TIME-DELAY, 250Vac, CLASS RK5 1315<br>DLS-(AMP) ECSR-(AMP) TIME-DELAY, 600Vac, CLASS RK5 1318<br>FNM-(AMP) LP-CC-(AMP) TIME-DELAY, [13] ⁄32” X 1 [1] ⁄2” FUSE 2028<br>FNQ-R-(AMP) LP-CC-(AMP)* TIME-DELAY, 500V, [13] ⁄32” X 1 [1] ⁄2” FUSE 1012<br>FNR-R-(AMP) LPN-RK-(AMP)SP TIME-DELAY, 250V, CLASS RK5 FUSES 1019/1020<br>FRS-R-(AMP) LPS-RK-(AMP)SP TIME-DELAY, 600V, CLASS RK5 FUSES 1017/1018<br>JKS-(AMP) LPJ-(AMP)SP FAST-ACTING, 600V, CLASS J FUSE 1026/1027<br>KLU-(AMP) KRP-C-(AMP)SP TIME-DELAY, CLASS L FUSE 1013<br>KTK-(AMP) KTK-R-(AMP) FAST-ACTING, 600V, [13] ⁄32” X 1 [1] ⁄2” FUSE 1011<br>KTK-R-(AMP) LP-CC-(AMP) FAST-ACTING, 600V, CLASS CC FUSE 1015<br>KTN-R-(AMP) LPN-RK-(AMP)SP FAST-ACTING, 250V, CLASS RK1 FUSE 1043<br>KTS-R-(AMP) LPS-RK-(AMP)SP FAST-ACTING, 600V, CLASS RK1 FUSE 1044<br>KTU-(AMP) KPR-C-(AMP)SP FAST-ACTING, 600V, CLASS L FUSE 1010<br>KWS-R-(AMP) LPS-RK-(AMP)SP FAST-ACTING, 600V, CLASS RK1 FUSE 1044<br>MDL-(AMP) MDA-(AMP) TIME-DELAY, [1] ⁄4” X 1 [1] ⁄4” FUSE 2004<br>MDL-V-(AMP) MDA-V-(AMP) TIME-DELAY, [1] ⁄4” X 1 [1] ⁄4” FUSE WITH LEADS 2004<br>MTH-(AMP) ABC-(AMP) FAST-ACTING, [1] ⁄4” X 1 [1] ⁄4” FUSE<br>NON-(AMP) LPN-RK-(AMP)SP GENERAL PURPOSE, 250V, CLASS H FUSES 1030<br>NOS-(AMP) LPS-RK-(AMP)SP GENERAL PURPOSE, 600V, CLASS H FUSES 1030<br>REN-(AMP) LPN-RK-(AMP)SP 250V RENEWABLE FUSELINK 1028<br>RES-(AMP) LPS-RK-(AMP)SP 600V RENEWABLE FUSELINK 1028<br>SL-(AMP) S-(AMP) TIME-DELAY, 125V, PLUG FUSE 1033<br>TL-(AMP) T-(AMP) TIME-DELAY, 125V, PLUG FUSE 1035<br>W-(AMP) TL-(AMP) TIME-DELAY, 125V, PLUG FUSE 1035<br>**----- End of picture text -----**<br>
*Not recommended for control transformer circuits.
Total measure of heat energy developed within a circuit during the fuse’s clearing of a fault current. Total Clearing I[2] t is the sum of the melting I[2] t and arcing I[2] t.
## **Voltage Rating**
The maximum open circuit voltage in which a fuse can be used, yet safely interrupt an overcurrent. Exceeding the voltage rating of a fuse impairs its ability to clear an overload or short-circuit safely.
## **Withstand Rating**
The maximum current that an unprotected electrical component can sustain for a specified period of time without the occurrence of extensive damage.
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**526**
**Application Guide**
## **Industrial Fuse Applications**
## **Industrial Applications**
**1. Interior Lighting**
**2. Computer Power**
**3. Switchboards**
**4. Motor Control Center**
**5. Emergency Lighting**
**6. UPS Backup Power Supplies**
**7. Transformer/Emergency Generator**
**8. Forklift Battery Charging Station**
**9. HVAC Chillers/Blowers**
**10. Welding Circuits**
**11. Plant Lighting**
**12. Distribution Panels**
**13. Disconnect Switches**
**14. Programmable Logic Circuits**
**15. Conveyor System**
## **Commercial Applications**
**1. Interior Lighting**
**2. HVAC Blowers**
**3. Computer Power**
**4. Branch Circuits**
**5. Emergency Lighting**
**6. Load Centers**
**7. Disconnect/Distribution Panels**
**8. HVAC/Chillers**
**9. Switchboards/Motor Control Centers**
**10. UPS Backup Power Supplies**
**11. Elevator Control Centers**
**12. Transformer/Emergency Generator**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**527**
**FUSEFinder Quick Cross Reference Guide**
Bussmann, the industry leader in critical circuit protection, power management and electrical safety offers an extensive selection of fuses and fuse blocks to meet precise overcurrent protection needs.
Whether it’s glass tube, low voltage or high speed fuse ... or fuse blocks needed for an application, you can use this FuseFinder Quick Cross Reference Guide to fi nd the Bussmann replacement. If you cannot fi nd a cross, more extensive listings are available online at www.cooperbussmann.com/FuseFinder. Or contact our Application Engineers at FuseTech@cooperindustries.com.
|**Competitor**<br>**Fuse Family**|**Bussmann**|**Competitor**<br>**Fuse Family**|**Bussmann**|**Competitor**<br>**Fuse Family**|**Bussmann**|
|---|---|---|---|---|---|
|0481(AMP)<br>211(AMP)<br>212(AMP)<br>213(AMP)<br>215(AMP)|GMT-(AMP)A<br>GDC-(AMP)<br>GDB-(AMP)<br>GDC-(AMP)<br>S505-(AMP)|413(AMP)<br>414(AMP)<br>417(AMP)<br>418(AMP)<br>429(AMP)|MDM-(AMP)<br>ABS-(AMP)<br>ABS-(AMP)<br>TR/3216FF-(AMP)<br>3216FF(AMP)|BDL(AMP)<br>BGC(AMP)<br>BGX(AMP)<br>BLF(AMP)<br>BLN(AMP)|MDL-(AMP)<br>AGC-(AMP)<br>AGX-(AMP)<br>BAF-(AMP)<br>BAN-(AMP)|
|216(AMP)<br>217(AMP)<br>218(AMP)<br>221(AMP)<br>226(AMP)|GDA-(AMP)<br>GDB-(AMP)<br>GDC-(AMP)<br>S505-V-(AMP)<br>GDA-V-(AMP)|431(AMP)<br>5140(AMP)<br>5170(AMP)<br>523(AMP)<br>5HF(AMP)|0603FA(AMP)<br>BAF-(AMP)<br>AGU-(AMP)<br>FNM-(AMP)<br>GDA-(AMP)|BLS(AMP)<br>BMA(AMP)<br>CBO(AMP) [4-160A]<br>CCK(AMP) [1-300A]<br>CCL(AMP) [30-100A]|BBS-(AMP)<br>GDA-(AMP)<br>HBO-(AMP)<br>ACK-(AMP)<br>ACL-(AMP)|
|227(AMP)<br>228(AMP)<br>230(AMP)<br>235(AMP)<br>236(AMP)|GDB-V-(AMP)<br>GDC-V-(AMP)<br>BK/C515-(AMP)<br>GMA-(AMP)<br>GMA-V-(AMP)|5HFP(AMP)<br>5HT(AMP)<br>5MF(AMP)<br>5MFP(AMP)<br>5SF(AMP)|GDA-V-(AMP)<br>BK/S505-(AMP)A<br>GMA-(AMP)<br>GMA-V-(AMP)<br>GDB-(AMP)|CCLB(AMP) [20-250A]<br>CCLW(AMP) [1-300A]<br>CCMR[1-30A Only]<br>CDNC(AMP)<br>CDSC(AMP)|KGJ-E-(AMP)<br>KGJ-(AMP)<br>LP-CC(AMP)<br>CDN(AMP)<br>CDS(AMP)|
|238(AMP)<br>239(AMP)<br>251(AMP)<br>252(AMP)<br>255(AMP) [1/16-5A]|GMD-V-(AMP)<br>GMD-(AMP)<br>MCRW-(AMP)<br>MCRW-(AMP)<br>MCRW-(AMP)|5ST(AMP)<br>6J(AMP)X<br>6R(AMP)D<br>702(AMP)<br>703(AMP)|GDC-(AMP)<br>KTK-(AMP)<br>LPS-RK-(AMP)SP<br>HVJ-(AMP)<br>HVL-(AMP)|CNL(AMP)<br>CNN(AMP)<br>DCT[1-15A]<br>E(AMP)FC<br>E(AMP)FE|ANL-(AMP)<br>ANN-(AMP)<br>PV-(AMP)A10F<br>(AMP)FC<br>(AMP)FE|
|256(AMP)<br>257(AMP)<br>275(AMP)<br>276(AMP)<br>297(AMP)[AUTOMOTIVEFUSE]|MCRW-(AMP)<br>ATC-(AMP)<br>MCRW-(AMP)<br>MCRW-(AMP)<br>ATM-(AMP)|81200(AMP)ST<br>A70P(AMP)-1 or Type 1<br>A70P(AMP)-4 or Type 4<br>A70Q(AMP)-4 or Type 4<br>A70QS(AMP)-14F|CBS-(AMP)<br>FWP-(AMP)A14F<br>FWP-(AMP)A orB<br>FWP-(AMP)A or B<br>FWP-(AMP)A14F|E(AMP)FET<br>E(AMP)FM<br>E(AMP)FMM<br>E(AMP)LCT [6-20A]<br>E(AMP)LET [25-180A]|(AMP)FET<br>(AMP)FM<br>(AMP)FMM<br>(AMP)LCT<br>(AMP)LET|
|299(AMP)<br>2AG220<br>2AG230<br>301(AMP)<br>303(AMP)|MAX-(AMP)<br>BK/C517-(AMP)<br>BK/C515-(AMP)<br>AGA-(AMP)<br>AGW-(AMP)|A70QS(AMP)-22F<br>A70QS[35-200]-4<br>A70QS[225-400]-4 or 4K<br>A70QS[450-600]-4K<br>A70QS[700-800]-4|FWP-(AMP)A22F<br>FWP-(AMP)A or B<br>FWP-(AMP)A or B<br>FWP-(AMP)A or B<br>FWP-(AMP)A or B|E(AMP)LMMT [315-900A]<br>E(AMP)LMT [160-450A]<br>E100SF(AMP) [20-30A]<br>E100S(AMP) [40-2000A]<br>E15S(AMP) [35-3000A]|(AMP)LMMT<br>(AMP)LMT<br>FWJ-(AMP)A14F<br>FWJ-(AMP)<br>FWA-(AMP)A|
|307(AMP)<br>311(AMP)<br>312(AMP)<br>313(AMP)<br>314(AMP)|SFE-(AMP)<br>AGC-(AMP)<br>AGC-(AMP)<br>MDL-(AMP)<br>ABC-(AMP)|A50P(AMP)-1<br>A50P(AMP)-4<br>A50QS(AMP)-4 or Type 4<br>A30QS(AMP)-1 or Type 1<br>A30QS[35-700]-4 or Type 4|FWH-(AMP)A14F<br>FWH-(AMP)A or B<br>FWH-(AMP)A or B<br>FWX-(AMP)A14F<br>FWX-(AMP)A|E15SF(AMP) [5, 10, 15, 20, 25, 30A]<br>E25S(AMP) [1000-2500A]<br>E25S(AMP) [35-800A]<br>E25SFX(AMP) [5-30A]<br>E50S(AMP)|FWA-(AMP)A10F<br>FWX-(AMP)AH<br>FWX-(AMP)A<br>FWX-(AMP)14F<br>FWH-(AMP)|
|315(AMP)<br>318(AMP)<br>322(AMP)<br>323(AMP)<br>324(AMP)|MDL-V-(AMP)<br>AGC-V-(AMP)<br>GBB-(AMP)<br>MDA-(AMP)<br>ABC-V-(AMP)|A30QS[1000-1200]-128<br>A15QS[1-30]-2<br>A15QS[35-60]-1<br>A15QS[70-400]-4<br>A2D(AMP)R|FWX-(AMP)AH<br>FWA-(AMP)A10F<br>FWA-(AMP)A21F<br>FWA-(AMP)B<br>LPN-RK(AMP)SP|E50SF(AMP) [5-30A]<br>E70S(AMP)<br>ECK(AMP) [1-300A]<br>ECL(AMP) [30-100A]<br>ECN(AMP)|FWH-(AMP)14F<br>FWP-(AMP)<br>ACK-(AMP)<br>ACL-(AMP)<br>FRN-R-(AMP)|
|325(AMP)<br>326(AMP)<br>334(AMP)<br>336(AMP)<br>361(AMP)|MDA-V-(AMP)<br>MDA-(AMP)<br>GLD-(AMP)<br>GBA-(AMP)<br>AGX-(AMP)|A2K(AMP)<br>A3T(AMP)<br>A4BQ[225-600]<br>A4BQ[601-6000]<br>A4BT[601-4000]|KTN-R(AMP)<br>JJN(AMP)<br>KRP-CL-(AMP)<br>KRP-C-(AMP)SP<br>KLU[601-4000]|ECNR(AMP)<br>ECS(AMP)<br>ECSR(AMP)<br>ELR(AMP)<br>ENLE(AMP)|FRN-R-(AMP)<br>FRS-R-(AMP)<br>FRS-R-(AMP)<br>GLR-(AMP)<br>ANL-(AMP)|
|362(AMP)<br>3770(AMP)<br>3780(AMP)<br>3785(AMP)<br>3AB(AMP)|AGX-(AMP)<br>SL-(AMP)<br>S-(AMP)<br>T-(AMP)<br>ABC-(AMP)|A4BY(AMP)<br>A4J(AMP)<br>A6D(AMP)R<br>A6K(AMP)<br>A6T(AMP)|KLU(AMP)<br>JKS(AMP)<br>LPS-RK(AMP)SP<br>KTS-R(AMP)<br>JJS(AMP)|ENNE(AMP)<br>ERN(AMP)<br>ERS(AMP)<br>ESA(AMP)<br>FA(AMP)|ANN-(AMP)<br>REN-(AMP)<br>RES-(AMP)<br>S-(AMP)<br>SA(AMP)|
|3ABP(AMP)<br>3AG(AMP)<br>3AG311(AMP)<br>3AG312(AMP)<br>3AG313(AMP)|AGC-V-(AMP)<br>AGC-(AMP)<br>AGC-(AMP)<br>AGC-(AMP)<br>MDL-(AMP)|AG(AMP)<br>AJT(AMP)<br>AM10/(AMP)<br>AOK(AMP)<br>ATDR(AMP)|SC(AMP)<br>LPJ(AMP)SP<br>LP-CC-(AMP)<br>ALS-(AMP)<br>LP-CC-(AMP)|FII(AMP)<br>FIIC(AMP)<br>FIIM(AMP) [125-200A]<br>FIIM(AMP) [80-100A]<br>FLA(AMP)|CGL-(AMP)<br>CGL-(AMP)<br>(AMP)M14CB<br>(AMP)L09CB<br>FNA-(AMP)|
|3AG315(AMP)<br>3AG318(AMP)<br>3SB(AMP)<br>3SBP(AMP)<br>401(AMP)<br>411(AMP)<br>412(AMP)|MDL-V-(AMP)<br>AGC-V-(AMP)<br>MDL-(AMP)<br>MDL-V-(AMP)<br>GMT-(AMP)A<br>ABS-(AMP)<br>ABS-(AMP)|ATM(AMP)<br>ATMR(AMP)<br>ATQ(AMP)<br>ATQR(AMP)<br>BBC(AMP)<br>BDB(AMP)<br>BDC(AMP)|KLM(AMP)<br>KTK-R(AMP)<br>FNQ-(AMP)<br>FNQ-R-(AMP)<br>ABC-(AMP)<br>GDB-(AMP)<br>GDC-(AMP)|FLM(AMP)<br>FLN(AMP)<br>FLNR(AMP)<br>FLQ(AMP)<br>FLS(AMP)<br>FLSR(AMP)<br>GFN(AMP)|FNM-(AMP)<br>FRN-R-(AMP)<br>FRN-R-(AMP)<br>FNQ-(AMP)<br>FRS-R-(AMP)<br>FRS-R-(AMP)<br>FNA-(AMP)|
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**528**
**FUSEFinder Quick Cross Reference Guide**
|**Competitor**<br>**Fuse Family**|**Bussmann**|**Competitor**<br>**Fuse Family**|**Bussmann**|**Competitor**<br>**Fuse Blocks1, 2, 3**|**Bussmann**|
|---|---|---|---|---|---|
|GGU(AMP)<br>GL10/(AMP)<br>HCLR(AMP)<br>HCTR(AMP)<br>HSJ(AMP)|AGU(AMP)<br>KTK-(AMP)<br>KTK-R-(AMP)<br>FNQ-R-(AMP)<br>DFJ(AMP)|RF(AMP)<br>RFS(AMP)<br>RLN(AMP)<br>RLS(AMP)<br>SAO(AMP)|REN(AMP)<br>RES(AMP)<br>REN-(AMP)<br>RES(AMP)<br>SA-(AMP)|203(XX)<br>206(XX)<br>210(XX)<br>220(XX)<br>240(XX)|H25030-(X)CR*<br>H25060-(X)CR*<br>HM25100-(X)CR**<br>HM25200-(X)CR**<br>HM25400-(X)CR**|
|IDSR[6-60A Only]<br>J(AMP)<br>JDL(AMP)<br>JFL(AMP)<br>JLLN(AMP)|FRS-R-(AMP)ID<br>JKS-(AMP)<br>LPJ-(AMP)SP<br>JKS-(AMP)<br>JJN-(AMP)|SBS(AMP)<br>SCL(AMP)<br>SCLR(AMP)<br>SEC(AMP)<br>SLC(AMP)|BBS-(AMP)<br>KTS-R-(AMP)<br>KTS-R-(AMP)<br>SC-(AMP)<br>SC-(AMP)|26(XX)<br>603(XX)<br>606(XX)<br>610(XX)<br>620(XX)|HM25600-(X)CR**<br>H60030-(X)CR*<br>H60060-(X)CR*<br>HM60100-(X)CR**<br>HM60200-(X)CR**|
|JLLS(AMP)<br>JLS(AMP)<br>JTD(AMP)<br>KLA(AMP) [5, 10, 15, 20, 25, 30A]<br>KLB(AMP) [1-30A]|JJS-(AMP)<br>JKS-(AMP)<br>LPJ-(AMP)SP<br>FWA-(AMP)A10F<br>FWX-(AMP)A14F|SLO(AMP)<br>SOO(AMP)<br>TLO(AMP)<br>TOO(AMP)<br>TR(AMP)|SL-(AMP)<br>S-(AMP)<br>TL-(AMP)<br>T-(AMP)<br>FRN-R-(AMP)|640(XX)<br>66(XX)<br>203(XX)R<br>206(XX)R<br>210(XX)R|HM60400-(X)CR**<br>HM60600-(X)CR**<br>R25030-(X)CR*<br>R25060-(X)CR*<br>RM25100-(X)CR**|
|KLC(AMP)<br>KLDR (AMP)<br>KLH(AMP) [1-30A]<br>KLH(AMP) [225-600A]<br>KLH(AMP) [35-200A]|KAC-(AMP)<br>FNQ-R-(AMP)<br>FWH-(AMP)A14F<br>FWH-(AMP)A<br>FWH-(AMP)B|TRM(AMP)<br>TRS(AMP)<br>WOO(AMP)<br>LFJ60030(X) / (X)ID<br>LFJ60060(X) / (X)ID<br>LFJ60100(X) / (X)ID<br>LFJ60200(X) / (X)ID<br>LFJ60400(X) / (X)ID<br>LFJ60600(X) / (X)ID<br>LFR25030(X) / (X)ID<br>**Competitor**<br>**Fuse Blocks1, 2, 3**|FNM-(AMP)<br>FRS-R(AMP)<br>W-(AMP)<br>J60030-(X)CR*<br>J60060-(X)CR*<br>JM60100-(X)CR**<br>JM60200-(X)CR**<br>JM60400-(X)CR**<br>JM60600-(X)CR**<br>R25030-(X)CR*<br>**Bussmann**|220(XX)R<br>240(XX)R<br>26(XX)R<br>603(XX)R<br>606(XX)R|RM25200-(X)CR**<br>RM25400-(X)CR**<br>RM25600-(X)CR**<br>R60030-(X)CR*<br>R60060-(X)CR*|
|KLK(AMP)<br>KLKR(AMP)<br>KLLU(AMP)<br>KLMR(AMP)<br>KLNR(AMP)|KTK-(AMP)<br>KTK-R-(AMP)<br>KLU-(AMP)<br>LP-CC-(AMP)<br>KTN-R-(AMP)|||610(XX)R<br>620(XX)R<br>640(XX)R<br>66(XX)R<br>US3J(X) / (X)I|RM60100-(X)CR**<br>RM60200-(X)CR**<br>RM60400-(X)CR**<br>RM60600-(X)CR**<br>CH30J(X) / (X)I|
|KLPC(AMP)<br>KLSR(AMP)<br>KLW(AMP)<br>KON(AMP)<br>KOS(AMP)|KRP-C-(AMP)SP<br>KTS-R-(AMP)<br>FWA-(AMP)10F<br>NON-(AMP)<br>NOS-(AMP)|||US6J(X) / (X)I<br>USPV<br>USCC(X) / (X)I<br>USM(X) / (X)I<br>(R)6J30A(X)S|CH60J(X) / (X)I<br>CHPV<br>CHCC(X)DU / (X)DIU<br>CHM(X)DU / CHM(X)DIU<br>J60030-(X)CR*|
|L(AMP)TD<br>L15S(AMP) [1-30A]<br>L15S(AMP) [35-60A]<br>L15S(AMP) [70-400A]<br>L25S(AMP) [1-30A]|KRP-C-(AMP)SP<br>FWA-(AMP)A10F<br>FWA-(AMP)A21F<br>FWA-(AMP)A<br>FWX-(AMP)A14F|LFR25060(X) / (X)ID<br>LFR25100(X) / (X)ID<br>LFR25200(X) / (X)ID<br>LFR25400(X) / (X)ID<br>LFR25600(X) / (X)ID|R25060-(X)CR*<br>RM25100-(X)CR**<br>RM25200-(X)CR**<br>RM25400-(X)CR**<br>RM25600-(X)CR**|(R)6J60A(X)B<br>R6J100A(X)B<br>6J200A(X)BFBD<br>6J400A(X)BFBD<br>6J600A(X)BFBD|J60060-(X)CR*<br>JM60100-(X)CR**<br>JM60200-(X)CR**<br>JM60400-(X)CR**<br>JM60600-(X)CR**|
|L50S(AMP) [1-30A]<br>L70S(AMP) [1-30A]<br>LCU(AMP)<br>LEN(AMP)<br>LENRK(AMP)|FWH-(AMP)A14F<br>FWP-(AMP)A14F<br>KTU-(AMP)<br>FRN-R-(AMP)<br>LPN-RK-(AMP)SP|LFR60030(X) / (X)ID<br>LFR60060(X) / (X)ID<br>LFR60100(X) / (X)ID<br>LFR60200(X) / (X)ID<br>LFR60400(X) / (X)ID|R60030-(X)CR*<br>R60060-(X)CR*<br>RM60100-(X)CR**<br>RM60200-(X)CR**<br>RM60400-(X)CR**|R30A(X)(XX)<br>R60A(X)(XX)<br>R100A(X)B<br>R200A(X)BE<br>R400A(X)B|R25030-(X)CR*<br>R25060-(X)CR*<br>RM25100-(X)CR**<br>RM25200-(X)CR**<br>RM25400-(X)CR**|
|LES(AMP)<br>LESR(AMP)<br>LESRK(AMP)<br>LGR(AMP)<br>LHR(AMP)|FRS-R-(AMP)<br>FRS-R-(AMP)<br>LPS-RK-(AMP)SP<br>GLR-(AMP)<br>HLR(AMP)|LFR60600(X) / (X)ID<br>LFH25030(X) / (X)ID<br>LFH25060(X) / (X)ID<br>LFH25100(X) / (X)ID<br>LFH25200(X) / (X)ID|RM60600-(X)CR**<br>H25030-(X)CR*<br>H25060-(X)CR*<br>HM25100-(X)CR**<br>HM25200-(X)CR**|R600A(X)B<br>6R30A(X)(XX)<br>6R60A(X)(XX)<br>6R100A(X)B<br>6R200A(X)BE|RM25600-(X)CR**<br>R60030-(X)CR*<br>R60060-(X)CR*<br>RM60100-(X)CR**<br>RM60200-(X)CR**|
|LKU(AMP)<br>LLNRK(AMP)<br>LLSRK(AMP)<br>MEN(AMP)<br>MEQ(AMP)|KLU-(AMP)<br>LPN-RK-(AMP)SP<br>LPS-RK-(AMP)SP<br>FNM-(AMP)<br>FNQ-(AMP)|LFH25400(X) / (X)ID<br>LFH25600(X) / (X)ID<br>LFH60030(X) / (X)ID<br>LFH60060(X) / (X)ID<br>LFH60100(X) / (X)ID|HM25400-(X)CR**<br>HM25600-(X)CR**<br>H60030-(X)CR*<br>H60060-(X)CR*<br>HM60100-(X)CR**|6R400A(X)B<br>6R600A(X)B<br>(R)F30A(X)(XX)<br>(R)F60A(X)(XX)<br>RF100A(X)B|RM60400-(X)CR**<br>RM60600-(X)CR**<br>H25030-(X)CR*<br>H25060-(X)CR*<br>HM25100-(X)CR**|
|MJS(AMP)<br>MOL(AMP)<br>MQ(AMP)<br>NCL(AMP)<br>NCLR(AMP)|BK/C515-(AMP)<br>BAF-(AMP)<br>MCRW-(AMP)<br>KTN-R-(AMP)<br>KTN-R-(AMP)|LFH60200(X) / (X)ID<br>LFH60400(X) / (X)ID<br>LFH60600(X) / (X)ID<br>LFPSJ30(X) / (X)ID<br>LFPSJ60(X) / (X)ID|HM60200-(X)CR**<br>HM60400-(X)CR**<br>HM60600-(X)CR**<br>CH30J(X) / (X)I<br>CH60J(X) / (X)I|F200A(X)BE<br>RF400A(X)B<br>F600A(X)B<br>(R)6F30A(X)(XX)<br>(R)6F60A(X)(XX)|HM25200-(X)CR**<br>HM25400-(X)CR**<br>HM25600-(X)CR**<br>H60030-(X)CR*<br>H60060-(X)CR*|
|NLN(AMP)<br>NLS(AMP)<br>OT(AMP)<br>OTM(AMP)<br>OTS(AMP)|NON-(AMP)<br>NOS-(AMP)<br>NON(AMP)<br>BAF-(AMP)<br>NOS(AMP)|LPHV<br>LPSC00(X) / (X)ID<br>LPSM00(X) / (X)ID<br>6030(X)J<br>6060(X)J|CHPV<br>CHCC(X)DU / (X)DIU<br>CHM(X)DU / CHM(X)DIU<br>J60030-(X)CR*<br>J60060-(X)CR*|R6F100A(X)B<br>6F200A(X)BE<br>R6F400A(X)B<br>6F600A(X)B<br>6SJ30A(X) / (X)I|HM60100-(X)CR**<br>HM60200-(X)CR**<br>HM60400-(X)CR**<br>HM60600-(X)CR**<br>CH30J(X) / (X)I|
|PICO<br>R224(AMP)<br>R230(AMP)<br>R251(AMP)T1<br><br>MCRW-(AMP)<br>TR2/C518-(AMP)A<br>TR/C515-(AMP)A<br>TR/MCRW-(AMP)<br><br>610(XX)J<br>620(XX)J<br>640(XX)J<br>66(XX)J<br> <br>6SJ60A(X) / (X)I<br>6SC30A(X)-C / (X)I-C<br>6SM30A(X)-C / (X)I-C<br><br>JM60100-(X)CR**<br>JM60200-(X)CR**<br>JM60400-(X)CR**<br>JM60600-(X)CR**<br> <br>CH60J(X) / (X)I<br>CHCC(X)DU / (X)DIU<br>CHM(X)DU / CHM(X)DIU||||||
- These Bussmann fuse blocks do not offer indication at this amperage, however a SAMI cover can be used to offer protection against accidental contact and open fuse indication.
- ** Finger-safe covers are available for this block along with optional open fuse indication.
1. Some competitor blocks are adder blocks and/or have multiple terminal offerings for Cu/Al or Cu only conductors. Bussmann blocks are not adder blocks below 100A, and all blocks are tin plated aluminum terminals to accommodate both Cu and Al conductors.
2. Wire ranges are not always the same. Please assure wire range is suitable for the application.
3. All blocks listed have a box lug for wire termination. Alternate connection types are available in the 30 and 60 amp range. If an alternate type is required, please see the appropriate Bussmann data sheet for part number ordering information.
**Data Sheets are available online at www.cooperbussmann.com/DatasheetsEle. For technical assistance, contact the Bussmann Application Engineering Team. Call 636-527-1270 between 8:00 AM and 5:00 PM Central Time, or e-mail FuseTech@cooperindustries.com.**
**For customer assistance, call the Customer Satisfaction Team toll-free 855-BUSSMANN (855-287-7626) or e-mail BussCustSat@cooperindustries.com.**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**529**
**FC2 Mobile App**
## Easily Calculate Available Fault Current Anytime, Anywhere
## FC[2] Mobile App Quickly Delivers Fault Current Calculations in the Palm of Your Hand
- Makes point-to-point calculations easy
- Calculate three-phase and single-phase faults
- Create and e-mail NEC[®] 110.24 compliant labels and one-line diagrams
- Fuse Sizing Guide assists with fuse and conductor sizing
- Works with or without a network connection
- Available for Apple and Android mobile devices
- FC[2] also available on-line in a web-based version
For product data sheets, visit www.cooperbussmann.com/FC2
**530**
**FC2 Mobile App**
## **One Tool for Easy Available Fault Current Calculations**
## **How to Install:**
- Use the QR Code with your device to download the mobile app
- Go to the Android or Apple App store
- OR • Search for “Fault Current Calculator” make sure to select the Bussmann FC2 icon
- Click “install” and follow the instructions
## **How to Use:**
**1 Calculator – Calculate Available Fault Current**
- Select either three-phase or single-phase
- Add components, calculate the system’s available fault current and review a one-line diagram
- E-mail one-line diagram at anytime
**2**
## **NEC[®] 110.24 Label – Helps Meet the Code**
- Allows calculation of the maximum available fault current at the service equipment and provides date of calculation
- Create and e-mail a label once a calculation is complete
- Print and use label to post the maximum available fault current
**3**
## **User Guide – Helpful Tips**
- Click “User Guide” to view helpful user tips
- Each page has explanations for performing calculations
## **4 Fuse Sizing Guide – For Main, Feeder and Branch Circuits**
- Click “Fuse Sizing” and “VIEW FUSE SIZING DIAGRAM”
- Click each blue “HOT SPOT” link in the one-line diagram for fuse and conductor sizing information
**5 Contact Us – Direct Contact to Industry Leading Support**
- Click “Contact Us”
- For application inquiries, click “TECHNICAL SUPPORT”
- For all other questions, click “CUSTOMER SERVICE”
- The FC2 app will automatically begin an e-mail to a Bussmann support representative
**==> picture [459 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>" SG 2 =_ ©<br>: Seer<br>3 a f a = f<br>eee i ce i es" c—! i | = Co :<br>5<br>4<br>**----- End of picture text -----**<br>
For product data sheets, visit www.cooperbussmann.com/FC2
**531**
**Index**
## **Catalog Number Index**
|__NZ01<br>255<br>__NZ02<br>255<br>_BS<br>263<br>_D125<br>255<br>_D16<br>255<br>_D27<br>255<br>_D33<br>255<br>_LSC<br>263<br>_NHG_ _ _B<br>256-258<br>1025<br>*<br>11 Type<br>438<br>11239<br>306<br>11240<br>306<br>11241<br>306<br>11242<br>306<br>11675-<br>329<br>11725-<br>329<br>11960<br>*<br>13195<br>*<br>13926<br>*<br>14002-<br>331<br>14004-<br>331<br>15087<br>436<br>15100-_<br>432<br>15149<br>424<br>15188-3<br>362<br>15188-4<br>362<br>15242<br>*<br>15595<br>*<br>15600<br>*<br>15602<br>*<br>15660<br>*<br>15800<br>430<br>15900<br>*<br>15968<br>*<br>160___<br>329,330<br>162___<br>329,330<br>163__<br>327-328,329,330<br>165___<br>329,330<br>170E_ _ _ _ 201-204,207-211<br>170F_ _ _ _<br>205-206<br>170H_ _ _ _<br>212-213<br>170L<br>*<br>170M_ _ _ _<br>145-199<br>170N<br>*<br>170R<br>*<br>170T<br>*<br>175GDMSJD<br>*<br>175GXQNJD<br>*<br>1976<br>*<br>1A0065<br>120<br>1A0835<br>*<br>1A1119-<br>96<br>1A1120-<br>96<br>**Catalog**<br>**Page**<br>**Number**|1A1310<br>*<br>1A1360<br>*<br>1A1478<br>*<br>1A1706-_<br>436<br>1A1837<br>*<br>1A1838<br>*<br>1A1853<br>*<br>1A1907-<br>96<br>1A2294<br>*<br>1A3398-<br>96<br>1A3399-<br>95<br>1A3400-<br>98<br>1A3746<br>*<br>1A4533-<br>96<br>1A4534-<br>96<br>1A4708<br>*<br>1A4806<br>*<br>1A5018-<br>95<br>1A5600-<br>84<br>1A5601-<br>95<br>1A5602-<br>95<br>1A5603<br>*<br>1A5778<br>84<br>1A5779<br>84<br>1A5780<br>84<br>1A5940<br>*<br>1A6049<br>*<br>1A8654<br>*<br>1B0048<br>*<br>1B0049<br>*<br>1BR021<br>*<br>1BR048<br>*<br>1BS1_ _ _<br>141,213<br>1CIF<br>*<br>2004<br>*<br>2081<br>*<br>21010<br>*<br>2127<br>*<br>2178<br>*<br>2201<br>*<br>2245<br>*<br>2322<br>*<br>24 Type<br>438<br>2429<br>*<br>2430<br>*<br>2432<br>*<br>246B9949BG<br>*<br>2487<br>*<br>2499<br>319<br>25499<br>*<br>2601<br>*<br>2604<br>*<br>2605<br>*<br>2607<br>*<br>**Catalog**<br>**Page**<br>**Number**|2608<br>*<br>2610<br>*<br>2611<br>*<br>2650<br>*<br>2654<br>*<br>2698<br>*<br>270303<br>120<br>2714<br>*<br>2772<br>*<br>2778<br>*<br>2795<br>*<br>2834<br>*<br>2837<br>*<br>2838<br>*<br>2839<br>*<br>2860<br>*<br>2989<br>*<br>2992<br>*<br>2A066<br>*<br>2A8<br>*<br>2P25G<br>345<br>3356<br>*<br>3375<br>*<br>3411<br>*<br>3429<br>*<br>3434<br>*<br>3512<br>*<br>3513<br>*<br>3515<br>*<br>3519<br>*<br>3520<br>*<br>3521<br>*<br>3528<br>*<br>3531<br>*<br>3545<br>*<br>3552<br>*<br>3553<br>*<br>3554<br>*<br>3555<br>*<br>3556<br>*<br>3562<br>*<br>3569<br>*<br>3571<br>*<br>3572<br>*<br>3575<br>*<br>3576<br>*<br>3578<br>*<br>3591<br>*<br>3594<br>*<br>3595<br>*<br>3604<br>*<br>3723<br>321<br>3742<br>321<br>3743<br>321<br>**Catalog**<br>**Page**<br>**Number**|3823<br>*<br>3828<br>320<br>3833<br>*<br>3835<br>321<br>3835<br>326<br>3839<br>*<br>3959<br>*<br>3998<br>*<br>39E<br>*<br>4121<br>*<br>4164<br>79<br>4164-FR<br>79<br>4178<br>*<br>4180<br>111<br>4202<br>*<br>4261<br>*<br>4287<br>*<br>4386<br>*<br>4393<br>320<br>4399<br>*<br>4402<br>*<br>4405<br>319<br>4406<br>319<br>4407<br>*<br>4408<br>*<br>4410<br>*<br>4412<br>*<br>4413<br>*<br>4421<br>321<br>4422<br>*<br>4423<br>*<br>4427<br>*<br>4428<br>*<br>4482<br>*<br>4512<br>*<br>4513<br>*<br>4514<br>*<br>4515<br>321<br>4520<br>320<br>4522<br>*<br>4525<br>*<br>4528<br>111<br>4529<br>111<br>4532<br>*<br>4535<br>*<br>4537<br>*<br>4561<br>*<br>4567<br>*<br>4574<br>319<br>4909<br>*<br>51215<br>*<br>51235<br>*<br>5591-<br>98<br>5592-<br>98<br>**Catalog**<br>**Page**<br>**Number**|**Catalog**<br>**Page**<br>**Number**|
|---|---|---|---|---|
|||||5623<br>*|
|||||5672-<br>98|
|||||5674-<br>98|
|||||5678<br>*|
|||||5681-<br>97|
|||||5682-<br>97|
|||||5950<br>*|
|||||5956-<br>98|
|||||5958<br>*|
|||||5960-<br>98|
|||||5961<br>*|
|||||5TPH<br>510|
|||||6125TD<br>*|
|||||6374<br>*|
|||||63A-DUMMY<br>*|
|||||6415<br>*|
|||||6417<br>*|
|||||6418<br>*|
|||||6419<br>*|
|||||6420<br>*|
|||||64200<br>74|
|||||6422<br>*|
|||||6424<br>*|
|||||6427<br>*|
|||||64300<br>74|
|||||64913<br>*|
|||||64926<br>*|
|||||65372<br>*|
|||||65398<br>*|
|||||68100<br>*|
|||||68300<br>74|
|||||68600<br>74|
|||||7 Type<br>438|
|||||70 Series<br>436|
|||||74 Type<br>438|
|||||75 Type<br>439|
|||||76 Type<br>439|
|||||80 Type<br>439|
|||||8414677<br>*|
|||||8588A81H<br>*|
|||||9078A67G04<br>120|
|||||9435<br>*|
|||||9483<br>*|
|||||9732<br>*|
|||||9789<br>*|
|||||9834<br>*|
|||||9835<br>*|
|||||9838<br>*|
|||||9841<br>*|
|||||9843<br>*|
|||||A3354705<br>*|
|||||A3354710<br>120|
|||||A3354720<br>*|
|||||A3354730<br>120|
* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle **532**
**Index**
## **Catalog Number Index**
|A3354745<br>120<br>A404302<br>*<br>AAO<br>253<br>ABC<br>91<br>ABCNA<br>108-109<br>ABC-V<br>91<br>ABGNA<br>109<br>ABS<br>*<br>ABU<br>*<br>ABWNA<br>108<br>AC<br>254<br>ACB<br>*<br>ACF<br>*<br>ACH<br>*<br>ACK<br>*<br>ACL<br>*<br>ACO<br>*<br>AD<br>254<br>ADL<br>*<br>ADLSJ<br>116<br>ADOSJ<br>116<br>AF<br>*<br>AFS<br>*<br>AFX<br>*<br>AGA<br>90<br>AGC<br>91<br>AGC-V<br>91<br>AGU<br>*<br>AGW<br>90<br>AGX<br>90<br>AGX-V<br>*<br>AGY<br>*<br>AL-D<br>279<br>ALS<br>*<br>ALW<br>*<br>AMG<br>*<br>AMI<br>*<br>AMWNA<br>108<br>ANL<br>79<br>ANN<br>79<br>ASZ350B3<br>*<br>AT<br>*<br>AT512 360<br>ATC<br>82<br>ATC-_ID<br>82<br>ATC-FHID 82<br>ATF<br>*<br>ATM<br>82<br>ATM-_ID<br>82<br>ATM-_LP<br>82<br>ATM-FHID<br>83<br>B221<br>272<br>B222<br>272<br>BAC_ 388, 391, 393, 395, 397<br>**Catalog**<br>**Page**<br>**Number**||399, 402, 406, 408, 410<br>413-414,419,421,423<br>BAF<br>75<br>BAN<br>*<br>BAO<br>253<br>BB1P_ _<br>279-280<br>BB3P_ _<br>279-280<br>BBS<br>77<br>BBU-EFID<br>*<br>BC(fuse blocks)<br>305<br>BC(fuses)<br>254<br>BC_(separator)<br>259<br>BCA603<br>304<br>BCC<br>*<br>BCF<br>*<br>BCPH2_PV<br>477-478<br>BD(fuses)<br>254<br>BFW<br>*<br>BG<br>305<br>BGH<br>*<br>BH-_ _ _ _<br>213<br>BH-_xxx<br>141<br>BH-_(fuseblocks)306<br>BM<br>305<br>BMA603<br>304<br>BNQ21<br>365<br>BOOR-508<br>413-414<br>BPG_NPE<br>468<br>BPG_NPEWE<br>486<br>BPH_-D_LV<br>460<br>BPH_YPV<br>478,480<br>BPM_IEC<br>468,470,472,474<br>BPM_UL<br>450,452,454,456<br>BPM_WE 486,488,490,492<br>BPM_YPV<br>478,480<br>BPMA_D_LV<br>458<br>BPP_SYPV<br>482<br>BPS_IEC<br>462,464,466<br>BPS_NPEIEC<br>466<br>BPSNPEIEC<br>470,474<br>BPSNPEWE<br>488,492<br>BQE<br>365<br>BQQ41<br>365<br>BRKT-_349,353<br>BRT<br>*<br>BRW<br>*<br>BSPD_DIN_<br>499-501<br>BSPD48RJ45<br>497-498<br>BSPD5BNCD_<br>493-494<br>BSPD5BNCSI<br>495-496<br>BSPG_NPE<br>467-468<br>BSPH_TNS<br>473-474<br>BSPH_TT<br>469-470<br>BSPH_TT<br>473-474<br>**Catalog**<br>**Page**<br>**Number**||BSPH_WE 487-488,491-492<br>BSPH_YPV<br>479-480<br>BSPH2A_D_LV<br>459-460<br>BSPM_S2G<br>449-450<br>BSPM_HLG<br>455-456<br>BSPM_S3G<br>451-452<br>BSPM_TN<br>467-468,469-470<br>BSPM_TNC<br>471-472<br>BSPM_WE<br>485-486<br>487-488,489-490,491-492<br>BSPM_WYG<br>453-454<br>BSPM_WYNG<br>455-456<br>BSPM1A_D_LV<br>457-458<br>BSPM-DLG<br>453-454<br>BSPP<br>481-482<br>BSPP_YPV<br>481-482<br>BSPS_PV<br>475-476<br>BSPS_TN<br>461-462<br>BSPS_TNC<br>463-464<br>BSPS_TNS<br>465-466<br>BSPS_TT<br>461-462,465-466<br>BSPS_WE<br>483-484,485-486<br>BVL-<br>259<br>C_NL<br>261<br>C002-0101-_<br>343<br>C002-0201<br>343<br>C002-0301<br>343<br>C08G_<br>260<br>C08M<br>261<br>C10G_<br>260<br>C10M_<br>261<br>C14G_<br>260,262<br>C14M_<br>261,262<br>C22G_<br>260,262<br>C22M_<br>261,262<br>C2617<br>*<br>C2791<br>*<br>C2909<br>*<br>C30BS<br>263<br>C30F<br>263<br>C30FBS<br>263<br>C4044<br>*<br>C4559<br>*<br>C515<br>86<br>C517<br>86<br>C518<br>86<br>C519<br>86<br>C520<br>86<br>C5237<br>*<br>C5268-<br>141<br>C5898<br>*<br>C60BS<br>263<br>C60F<br>263<br>C60FBS<br>263<br>**Catalog**<br>**Page**<br>**Number**||C6344<br>*<br>C7018<br>*<br>C7019<br>*<br>C7021-<br>376<br>C7024-<br>377<br>CAV<br>108-109<br>CAVH<br>108-109<br>CBB<br>*<br>CBC<br>*<br>CBF<br>*<br>CBP<br>*<br>CBS<br>*<br>CBT<br>*<br>CBU<br>*<br>CCB<br>*<br>CCG<br>*<br>CCP-_<br>380-383<br>CCPB-_<br>384-385<br>CCPHM-_<br>381,383<br>CCSK-45<br>506<br>CD<br>254<br>CD100<br>*<br>CD27<br>*<br>CDB<br>*<br>CDC<br>*<br>CDN<br>247<br>CDS<br>247<br>CEO<br>253<br>CFP-_<br>510<br>CGL<br>248<br>CH10CL<br>*<br>CH10CM<br>*<br>CH14<br>277<br>CH22<br>277<br>CH30J_<br>277,281<br>CH60J_<br>277,281<br>CH8<br>274-277<br>CHCC<br>274-277<br>CHM<br>274-277<br>CH-PLC<br>278<br>CHPV<br>274-277<br>CIF<br>249<br>CIH<br>251<br>CIK<br>251<br>CIL<br>251<br>CJ<br>250<br>CL1<br>222<br>CM__CF<br>263<br>CP14002<br>*<br>CS_<br>259<br>CSC_<br>334, 335, 336, 337<br>338,341,343,344,351,352<br>CT<br>218-219<br>CUG<br>*<br>**Catalog**<br>**Page**<br>**Number**||DD<br>254<br>DDNS10<br>343<br>DDP30<br>338<br>DEO<br>253<br>DFJ<br>125<br>DG100<br>340<br>DG150<br>340<br>DG230<br>340<br>DG25<br>339<br>DG35<br>339<br>DG60<br>339<br>DIA<br>*<br>DIR-_<br>388, 390, 392, 394<br>396, 398, 402, 406, 408, 410<br>413-414<br>DIS10<br>338<br>DKNSPS-<br>334,349<br>DKSPS_<br>335,336,343,349<br>DM20<br>337<br>DM30<br>337<br>DM50<br>337<br>DP100<br>336<br>DP150<br>336<br>DP230<br>336<br>DP25<br>335,338<br>DP45<br>335<br>DP60<br>336<br>DPLT-_<br>354<br>DRA-_<br>509<br>DRL_ 334, 335, 336, 337, 338<br>339, 340, 341, 342, 343, 353<br>358,359,360,362<br>DRLC-A<br>*<br>DS_<br>335, 336, 338, 343, 345<br>348,350,352<br>DS20<br>334<br>DS30<br>334<br>DS50<br>334<br>DSS_<br>334,350<br>DTST2<br>343<br>E-6188<br>*<br>EC-_ _ _<br>222<br>ECAP_<br>279-280<br>ECL055-<br>105<br>ECL083-<br>106<br>ECL155-<br>107<br>ED<br>254<br>EET<br>218,220<br>EF<br>254<br>EFS<br>254<br>ENA<br>*<br>ER1-_800L3PB<br>418<br>**Catalog**<br>**Page**<br>**Number**<br>**Index by**<br>**Part Number**|
|---|---|---|---|---|---|---|---|---|
|||||||||ER1-_J3PB<br>418<br>ER1-_N3SB<br>420, 422|
* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**533**
**Index**
## **Catalog Number Index**
|**Catalog**<br>**Page**<br>**Number**||**Catalog**<br>**Page**<br>**Number**||**Catalog**<br>**Page**<br>**Number**||**Catalog**<br>**Page**<br>**Number**||**Catalog**<br>**Page**<br>**Number**|
|---|---|---|---|---|---|---|---|---|
|ER12-_J3PB<br>418<br>ER12-_N3SB<br>420,422<br>ER12-800L3PB<br>418<br>ER3R-_J3PB<br>418<br>ER3R-_N3SB<br>420,422<br>ER3R-800L3PB<br>418<br>ER4-_J3JPB<br>418<br>ER4-_N3SB<br>420,422<br>ER4-800L3PB<br>418<br>ER4P-_J3PB<br>418<br>ER4P-_N3SB<br>420,422<br>ER4P-800L3PB<br>418<br>ER4X-_J3PB<br>418<br>ER4X-_N3SB<br>420,422<br>ER4X-800L3PB<br>418<br>ERK-28<br>507<br>ERS2<br>*<br>ERS30<br>*<br>ESD<br>253<br>ET<br>218-219<br>ETF<br>*<br>F01A<br>*<br>F02A<br>*<br>F02B<br>*<br>F03A<br>*<br>F03B<br>*<br>F09A<br>*<br>F09B<br>*<br>F10A<br>*<br>F15A<br>*<br>F16A<br>*<br>F520DDST<br>341<br>F520ST<br>341<br>F520STLED<br>341<br>F520T0P<br>342<br>F60C<br>*<br>F61C<br>*<br>F62C<br>*<br>F63C<br>*<br>F64C<br>*<br>F65C<br>*<br>FA02<br>*<br>FA2A<br>*<br>FA4H<br>*<br>FBP<br>*<br>FC<br>*<br>FC_(fuse casing)<br>259<br>FCB<br>*<br>FCC<br>*<br>FCF<br>28-29<br>FCU<br>*<br>FDM<br>*<br>FE<br>218,221<br>FEE<br>218, 221||FEH<br>259<br>FF<br>254<br>FG<br>254<br>FHL<br>*<br>FHN<br>*<br>FL-<br>*<br>FL11H_<br>117-119<br>FL11K_<br>117-119<br>FL11N<br>*<br>FL11T__<br>117-119<br>FL12K__<br>117-119<br>FL1A5<br>*<br>FL3H<br>*<br>FL3K__<br>117-119<br>FL3T__<br>117-119<br>FLB<br>*<br>FLC_<br>390,392,394,396,399<br>FLD<br>*<br>FLF<br>*<br>FLH_<br>390,392,394,396,399<br>FLM<br>*<br>FLN<br>*<br>FLRM 390,392,394,396,399<br>FLS<br>*<br>FM<br>218,221<br>FM01A<br>*<br>FM08A<br>*<br>FM09A<br>*<br>FM09B<br>*<br>FMM<br>218,221<br>FMX<br>*<br>FNA<br>78<br>FNM<br>76<br>FNQ<br>76<br>FNQ-R<br>24<br>FNW<br>*<br>FP-_<br>510<br>FPK_-3P<br>259<br>FRN-R<br>46<br>FRN-R-__ID<br>46<br>FRS-R<br>47<br>FRS-R-__ID<br>47<br>FT-_<br>510<br>FTI<br>*<br>FTM<br>*<br>FWA<br>126-129,224-225<br>FWC<br>232-233<br>FWH<br>132-133,228-231<br>FWJ<br>139-140,240-241<br>FWK<br>238-239<br>FWL<br>242<br>FWP<br>136-138,234-237<br>FWS<br>242<br>FWX<br>130-131, 226-227||GBA<br>78<br>GBB<br>91<br>GBB-V<br>91<br>GBC<br>*<br>GF<br>254<br>GFA<br>*<br>GG<br>254<br>GH<br>254<br>GKB<br>436<br>GLD<br>78<br>GLN<br>*<br>GLP<br>263<br>GLQ<br>80<br>GLR<br>81<br>GLX<br>*<br>GMA<br>89<br>GMA-V<br>89<br>GMC<br>89<br>GMC-V<br>89<br>GMD<br>89<br>GMD-V<br>89<br>GMF<br>81<br>GMQ<br>80<br>GMT-_<br>437<br>GMW<br>*<br>GRF<br>81<br>GSK-260<br>506<br>GV_<br>284<br>H07C<br>252<br>H12-_<br>388,390,392,394,396,398,408<br>H25_<br>294-295<br>H4X-_<br>388,390,392,394,396,398,402,4<br>06,408,410,413-414<br>H60_<br>296-297<br>H79-_<br>388,390,392,395,397,399,402<br>HAS-R<br>*<br>HBC<br>*<br>HBH<br>94<br>HBH-I<br>94<br>HBH-M<br>94<br>HBM<br>*<br>HBO<br>*<br>HBP-<br>*<br>HBS-<br>*<br>HBV-I<br>94<br>HBV-M<br>94<br>HBW-I<br>94<br>HBW-M<br>94<br>HCM<br>*<br>HEB<br>310-311<br>HEC<br>310||HEF<br>*<br>HEG<br>309<br>HEH<br>309<br>HEJ<br>310<br>HET<br>310<br>HEX<br>310<br>HEY<br>310<br>HEZ<br>310<br>HFA<br>309<br>HFB<br>308<br>HGA<br>*<br>HGB<br>*<br>HGC<br>*<br>HHB<br>308<br>HHC<br>82<br>HHD<br>82<br>HHF<br>82<br>HHG<br>82<br>HHL<br>83<br>HHM<br>83<br>HHT<br>309<br>HHX<br>83<br>HIF<br>*<br>HJL<br>316<br>HJM<br>*<br>HKA<br>*<br>HKL<br>316<br>HKP<br>313<br>HKQ<br>*<br>HKR<br>316<br>HKT<br>316<br>HKU<br>316<br>HKX<br>316<br>HLD<br>316<br>HLQ<br>80<br>HLQ-_<br>80<br>HLR<br>81<br>HLS<br>437<br>HLT<br>437<br>HM25100<br>289-293<br>HM25200<br>289-293<br>HM25400<br>289-293<br>HM25600<br>289-293<br>HM60100<br>289-293<br>HM60200<br>289-293<br>HM60400<br>289-293<br>HM60600<br>289-293<br>HME<br>309<br>HMF<br>309<br>HMG<br>309<br>HMH<br>309<br>HMI<br>309<br>HMJ<br>309<br>HMK<br>*||HMR<br>*|
|||||||||HN-1<br>*|
|||||||||HN-5<br>*|
|||||||||HPC-D<br>318|
|||||||||HPD<br>317|
|||||||||HPF<br>317|
|||||||||HPG<br>317|
|||||||||HPL<br>*|
|||||||||HPM<br>318|
|||||||||HPS<br>317|
|||||||||HPS2<br>318|
|||||||||HRE<br>309|
|||||||||HRF<br>309|
|||||||||HRG<br>309|
|||||||||HRH<br>309|
|||||||||HRI<br>309|
|||||||||HRJ<br>309|
|||||||||HRK<br>308|
|||||||||HSK<br>*|
|||||||||HTB-<br>314-315|
|||||||||HTC-140M<br>95|
|||||||||HTC-15M<br>95|
|||||||||HTC-200M<br>95|
|||||||||HTC-210M<br>95|
|||||||||HTC-30M<br>*|
|||||||||HTC-35M<br>312|
|||||||||HTC-40M<br>312|
|||||||||HTC-45M<br>93|
|||||||||HTC-50M<br>93|
|||||||||HTC-55M<br>312|
|||||||||HTC-70M<br>312|
|||||||||HVA<br>111|
|||||||||HVB<br>111|
|||||||||HVJ<br>111|
|||||||||HVL<br>111|
|||||||||HVR<br>111|
|||||||||HVT<br>111|
|||||||||HVU<br>111|
|||||||||HVW<br>111|
|||||||||HVX<br>111|
|||||||||HWA<br>*|
|||||||||IXL70F<br>*|
|||||||||J-_ _<br>511|
|||||||||J101/J<br>*|
|||||||||J201/J<br>*|
|||||||||J301/J<br>*|
|||||||||J60__<br>298|
|||||||||J70032<br>243|
|||||||||J70100<br>243|
|||||||||JB1<br>*|
|||||||||JCA<br>*|
|||||||||JCD-<br>110|
|||||||||JCG-<br>112|
|||||||||JCH-<br>112|
* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle **534**
**Index**
## **Catalog Number Index**
|JCI-<br>110<br>JCK-<br>112-114<br>JCK-A-<br>112-114<br>JCK-B-<br>112-114<br>JCL-<br>112-114<br>JCL-A-<br>112-114<br>JCL-B-<br>112-114<br>JCM<br>*<br>JCN<br>*<br>JCP<br>*<br>JCQ-<br>110<br>JCR-A<br>112-114<br>JCR-B-<br>112-114<br>JCT-<br>110<br>JCU-<br>104<br>JCW-<br>110<br>JCX-<br>103<br>JCY-<br>103<br>JCZ-<br>104<br>JDN<br>*<br>JDZ-<br>104<br>JF1<br>*<br>JJN-<br>48<br>JJS-<br>49<br>JKS<br>36<br>JM60100<br>289-293<br>JM60200<br>289-293<br>JM60400<br>289-293<br>JM60600<br>289-293<br>JN_<br>358, 359, 360, 361<br>362,363,364<br>JNDN3<br>358<br>JP600<br>299<br>JPA-3<br>*<br>JSK-36<br>506<br>JT<br>286-287<br>JTN<br>286-287<br>JU<br>*<br>K07C<br>252<br>KAB<br>*<br>KAC<br>134<br>KAD<br>364<br>KAD<br>*<br>KAF<br>*<br>KAJ<br>*<br>KAL<br>*<br>KAW<br>*<br>KAX<br>*<br>KAZ<br>79<br>KBC<br>135<br>KBD<br>*<br>KBJ<br>*<br>KBR<br>*<br>KBT<br>*<br>**Catalog**<br>**Page**<br>**Number**||KBY<br>*<br>KCF<br>74<br>KCH<br>74<br>KCJ<br>74<br>KCM<br>74<br>KCM-B<br>74<br>KCR<br>74<br>KCS<br>74<br>KCV<br>74<br>KCY<br>74<br>KCZ<br>74<br>KDA<br>74<br>KDB<br>74<br>KDC<br>74<br>KDD<br>74<br>KDE<br>74<br>KDF<br>74<br>KDH<br>74<br>KDJ<br>74<br>KDM<br>74<br>KDP<br>74<br>KDR<br>74<br>KDT<br>74<br>KDU<br>74<br>KDY<br>74<br>KEF<br>*<br>KEM<br>*<br>KER<br>*<br>KEW<br>74<br>KEX<br>74<br>KFH-A<br>74<br>KFM<br>74<br>KFT<br>74<br>KFZ<br>74<br>KGC<br>*<br>KGJ<br>*<br>KGJ-A<br>*<br>KGJ-E<br>*<br>KGL<br>*<br>KGO-E<br>*<br>KGS<br>*<br>KGS-A<br>*<br>KGT<br>*<br>KGX<br>*<br>KIG<br>74<br>KIT-6POLE<br>413,415<br>KJA<br>*<br>KLC<br>*<br>KLM<br>75<br>KLP<br>*<br>KLU<br>40<br>KMH-C<br>*<br>KPF<br>74<br>KQO<br>74<br>**Catalog**<br>**Page**<br>**Number**||KQT<br>74<br>KQV<br>74<br>KQW-M<br>*<br>KRP-C__SP<br>38-39<br>KRP-CL<br>39<br>KS-19392-L36<br>*<br>KT3<br>364<br>KT4<br>364<br>KTK<br>75<br>KTK-R<br>25<br>KTN-R<br>44<br>KTN-S<br>*<br>KTS-R<br>45<br>KTS-S<br>*<br>KTU<br>40<br>KU_(terminal blocks)<br>375<br>KWN-R<br>*<br>L09C<br>252<br>L14C<br>252<br>LAA<br>*<br>LAC<br>*<br>LAG<br>*<br>LAN<br>*<br>LAR<br>*<br>LCT<br>215-216<br>LEF<br>*<br>LET<br>215-216<br>LKB<br>*<br>LKC<br>*<br>LKN<br>*<br>LKS<br>*<br>LMMT<br>215,217<br>LMT<br>215,217<br>LP-CC<br>23<br>LPJ__SP<br>35<br>LPJ__SPI<br>35<br>LPN-RK__SP<br>41-43<br>LPN-RK__SPI<br>41-43<br>LPRK-28<br>507<br>LPS-RK__SP<br>41-43<br>LPS-RK__SPI<br>41-43<br>LPT<br>*<br>LUG1-_<br>398,408<br>LUG2-_<br>398,408<br>LUG3-_<br>408<br>LUG5-_<br>402,410<br>M09C<br>252<br>MAI<br>222<br>MAS<br>*<br>MAX-<br>83<br>MAX-__ID<br>83<br>MB-<br>52<br>MBO<br>*<br>MC_ _ _<br>222<br>**Catalog**<br>**Page**<br>**Number**||MCRW<br>*<br>MDA<br>92<br>MDA-V<br>92<br>MDL<br>92<br>MDL-V<br>92<br>MDM<br>*<br>MDQ<br>92<br>MDQ-V<br>92<br>MFN<br>*<br>MIC<br>78<br>MIJ<br>*<br>MIN<br>78<br>MIS<br>79<br>MKB<br>*<br>MMT<br>218,220<br>MSK-45<br>506<br>MT<br>218,220<br>MT12<br>*<br>MT12-1-2<br>358, 359, 360, 361<br>363,364,365<br>MTC6<br>358,364<br>MTMU<br>*<br>MV055-<br>101<br>MV155-<br>102<br>N512<br>360<br>NBB<br>*<br>NBC<br>*<br>NBE<br>*<br>NC3 361<br>ND-1260<br>*<br>NDN1<br>359<br>NDN111 359<br>NDN3 358<br>NDN63 358<br>NDND1<br>*<br>NDNF1-WH<br>322<br>NDNFD1-WH<br>322<br>NDNLFD1-WH<br>322<br>NDNV4 358<br>NFA<br>*<br>NFT2 360<br>NFT3 360<br>NFTA Series<br>353, 358, 359<br>360,361,362,363,365<br>NI<br>263<br>NITD<br>253<br>NNB<br>511<br>NNB-R<br>511<br>NNC<br>511<br>NO.1<br>409<br>NO.100<br>*<br>NO.140<br>508<br>NO.2<br>509<br>NO.201<br>*<br>**Catalog**<br>**Page**<br>**Number**||**Catalog**<br>**Page**<br>**Number**|
|---|---|---|---|---|---|---|---|---|
|||||||||NO.205<br>*|
|||||||||NO.213<br>511|
|||||||||NO.213-R 511|
|||||||||NO.216<br>511|
|||||||||NO.216-R<br>511|
|||||||||NO.220<br>508|
|||||||||NO.226<br>511|
|||||||||NO.226-R<br>511|
|||||||||NO.242-R<br>511|
|||||||||NO.2621<br>511|
|||||||||NO.2621-R<br>511|
|||||||||NO.263<br>511|
|||||||||NO.263-R<br>511|
|||||||||NO.2641<br>511|
|||||||||NO.2641-R<br>511|
|||||||||NO.2642<br>511|
|||||||||NO.2661-R<br>511|
|||||||||NO.2662-R<br>511|
|||||||||NO.2664-R<br>511|
|||||||||NO.270<br>508|
|||||||||NO.36<br>507|
|||||||||NO.4<br>509|
|||||||||NO.5<br>509|
|||||||||NO.6<br>509|
|||||||||NO.616<br>511|
|||||||||NO.616-R<br>511|
|||||||||NO.626<br>511|
|||||||||NO.626-R<br>511|
|||||||||NO.642-R<br>511|
|||||||||NO.663<br>511|
|||||||||NO.663-R<br>511|
|||||||||NO.7<br>509|
|||||||||NO.8<br>509|
|||||||||NON<br>37|
|||||||||NOS<br>37|
|||||||||NPL<br>*|
|||||||||NRA Series<br>353, 358, 359<br>360,361,362,363,365|
|||||||||NSD<br>253|
|||||||||NSE3<br>361|
|||||||||NSS3<br>361|
|||||||||NTN-R-_<br>511|
|||||||||NTQ23<br>365|
|||||||||NTS-R-_<br>511|
|||||||||NUE<br>*|
|||||||||NXA<br>*|
|||||||||NXC<br>*|
|||||||||OIA<br>*|
|||||||||OJ<br>*|
|||||||||OPM-1038<br>282-283|
|||||||||OPM-NG<br>284-285|
|||||||||OSD<br>253|
|||||||||P-<br>51|
|||||||||P09C<br>252|
* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**535**
**Index**
## **Catalog Number Index**
|P11C<br>252<br>P20S<br>344<br>P25G<br>345<br>P30S<br>344<br>P65S<br>344<br>PCB<br>*<br>PCC<br>*<br>PCD<br>*<br>PCF<br>*<br>PCG<br>*<br>PCH<br>*<br>PCI-<br>*<br>PCT<br>437<br>PDB___<br>324,226<br>PDBFS___<br>324-325<br>PLK3<br>364<br>PLU1<br>363<br>PLU3<br>362<br>PMP<br>268-269<br>POLE-_<br>413,415<br>POLE98-_<br>406<br>PON<br>247<br>PS<br>268-269<br>PS1RPLSW<br>*<br>PSU1<br>363<br>PV-<br>60<br>PV-_01XL<br>63<br>PV-_01XL15<br>67-69<br>PV-_10_<br>60<br>PV-_14F<br>61<br>PV-_14LF<br>66<br>PV-_1XL<br>63-64<br>PV-_2XL<br>63-64<br>PV-_2XL-15<br>67-69<br>PV-_3L<br>63-64<br>PV-_3L-15<br>67-69<br>PV-_NH1<br>62<br>PVCF<br>57-58<br>PVM<br>56<br>PVS-R<br>59<br>PWR1PLP<br>279-280<br>PWR35MM<br>279-280<br>PWR50MM<br>279-280<br>QC202/J<br>*<br>QC203/J<br>*<br>Quik-Spe c AC Safety Switch<br>271<br>Quik-Spec Coordination<br>Panelboards<br>266-267<br>Quik-Spec DC Safety Switches<br>270<br>R11C<br>252<br>R25_<br>294-295<br>R60_<br>296-297<br>**Catalog**<br>**Page**<br>**Number**|RD100_<br>404-406,420<br>RD1000_<br>404-405,410<br>RD100-3-SCCR 404-405,408<br>RD1200_<br>404-405,410,420<br>RD16_<br>412-414,422<br>RD200_<br>404-405,408,420<br>RD25_<br>412-414,422<br>RD30_<br>404-406,420<br>RD40_<br>412-414,422<br>RD400_<br>404-405,408,420<br>RD60_<br>404-406,420<br>RD600_<br>404-405,410,420<br>RD63_<br>412-414,422<br>RD80_<br>412-414,422<br>RD800_<br>404-405,410,420<br>RDF100_<br>387,396,418<br>RDF200_<br>387,398,418<br>RDF30_<br>387-390,418<br>RDF400_<br>387,398,418<br>RDF60_<br>387,392-394,418<br>RDF600_<br>387,402,418<br>RDF800_<br>387,402,418<br>REG<br>*<br>REN<br>*<br>RES<br>*<br>RFL<br>*<br>RK1SK-39<br>506<br>RK5SK-39<br>506<br>RLA<br>*<br>RLC<br>*<br>RYA<br>*<br>RYC<br>*<br>S-<br>51<br>S500<br>87<br>S500-V<br>87<br>S501<br>87<br>S501-V<br>87<br>S505<br>87<br>S505H<br>88<br>S505H-V<br>88<br>S505-V<br>87<br>S506<br>88<br>S506-V<br>88<br>S-8001<br>319<br>S-8002<br>319<br>S-8101<br>319<br>S-8102<br>319<br>S-8201<br>319<br>S-8202<br>219<br>S-8203<br>319<br>S-8301<br>319<br>SA-<br>52<br>SAMI-<br>288<br>SB_<br>259<br>**Catalog**<br>**Page**<br>**Number**|SC<br>34<br>SCV15<br>*<br>SCV20<br>*<br>SCY<br>307<br>SD_-S<br>63,67<br>SF25H<br>*<br>SFB1030<br>*<br>SFC-_<br>510<br>SFD27<br>*<br>SFE<br>*<br>SFR<br>*<br>SFR1<br>*<br>SH1-_<br>388<br>SH2-_<br>388<br>SH4-_<br>406,413-414<br>SH5-_<br>390, 392, 394 ,396<br>398,408<br>SH6-_<br>410<br>SH7-_<br>402<br>SH-GUIDE _<br>406, 408, 410<br>413-414<br>SKA<br>307<br>SL-<br>50<br>SL_<br>259<br>SNL-7K<br>*<br>SOU<br>307<br>SOW<br>307<br>SOX<br>307<br>SOY<br>307<br>SP_<br>259<br>SPH50SP_<br>PN442-445<br>SPH50SP_<br>PNG442-445<br>SPH50SP_<br>SN442-445<br>SPH50SP_<br>SNG442-445<br>SPH50SP_<br>WYG 442-445<br>SPH50SP_<br>WYGN 442-445<br>SPH50SP_<br>HLG 442-445<br>SPH50SP_DLG<br>442-445<br>SPJ<br>*<br>SPOD_<br>502-503<br>SPP<br>*<br>SPP40SP_DLG<br>446-448<br>SPP40SP_PN<br>446-448<br>SPP40SP_SN<br>446-448<br>SPP40SP_WYG<br>446-448<br>SRD<br>*<br>SRT-A<br>*<br>SRU<br>307<br>SRU-BC<br>*<br>SRW<br>307<br>SRX<br>307<br>SRY<br>307<br>SSD<br>253<br>SSN<br>307<br>**Catalog**<br>**Page**<br>**Number**|SSU<br>307<br>SSW<br>307<br>SSX<br>307<br>SSY<br>307<br>STD<br>253<br>STI<br>*<br>STM<br>*<br>STY<br>307<br>T-<br>51<br>T30__<br>300-301<br>T60__<br>302-303<br>TB_-D<br>259<br>TB00_<br>259<br>TB100-<br>366-367<br>TB200-<br>368-369<br>TB300-<br>370-371<br>TB345-<br>370-371<br>TB400-<br>374<br>TC<br>51<br>TCF<br>26-27<br>TCF__RN<br>26-27<br>TCFH_N<br>32-33<br>TCFH_NW 32-33<br>TCP<br>*<br>TDC<br>*<br>TDC10<br>*<br>TDC11<br>*<br>TDC180<br>*<br>TDC600<br>*<br>TDLEJ<br>116<br>TDLSJ<br>116<br>TDMEJ<br>116<br>TDQSJ<br>116<br>TFC<br>*<br>TFF<br>*<br>TFL<br>*<br>TFLSJ<br>116<br>TFMEJ<br>116<br>TFQSJ<br>116<br>TGH<br>*<br>THLEJ<br>116<br>THMEJ<br>116<br>TI_<br>222<br>TIQ<br>*<br>TJD<br>*<br>TKLEJ<br>116<br>TKMEJ<br>116<br>TL-<br>50<br>TM2_<br>334, 335, 336, 337<br>338, 341, 343, 344, 345<br>354-357<br>TP158HC<br>431<br>TP15900<br>*<br>TP15900-4_429<br>**Catalog**<br>**Page**<br>**Number**|**Catalog**<br>**Page**<br>**NumberCatalog**<br>**Pagember**|
|---|---|---|---|---|
|||||TP15914<br>428|
|||||TPA<br>429|
|||||TPA-B<br>429|
|||||TPB<br>*|
|||||TPC<br>426|
|||||TPCDS<br>426|
|||||TPH<br>*|
|||||TPHCS-_433|
|||||TPJ<br>*|
|||||TPL-_<br>434|
|||||TPM<br>427|
|||||TPMDS<br>427|
|||||TPN-_<br>435|
|||||TPS<br>430|
|||||TPSFH-_<br>510|
|||||TPW<br>*|
|||||TPWDS<br>*|
|||||TRF<br>*|
|||||TSH_-_<br>399, 402, 406, 409<br>411,413,415,419,421,423|
|||||TVS_<br>504|
|||||TVSS-<br>*|
|||||TXLEJ<br>116|
|||||TXMEJ<br>116|
|||||TXQEJ<br>116|
|||||UHA<br>*|
|||||UHC<br>*|
|||||UHJ<br>*|
|||||UHS<br>*|
|||||UHT<br>*|
|||||UHW<br>*|
|||||ULR<br>*|
|||||VFNHA<br>115|
|||||VKNHA<br>115|
|||||W-<br>50|
|||||WCF<br>30-31|
|||||WCF__RN<br>30-31|
|||||WDFHO<br>115|
|||||WDLSJ<br>115-116|
|||||WDOH6<br>115|
|||||WDOSJ<br>116|
|||||WER<br>438|
|||||WFFHO<br>115|
|||||WFLSJ<br>115-116|
|||||WFMSJ<br>115|
|||||WFNHO<br>115|
|||||WFOH6<br>115|
|||||WFOSJ<br>116|
|||||WGA<br>*|
|||||WHA<br>*|
|||||WHN<br>*|
|||||WIE<br>*|
|||||WJON6 115|
|||||WKB<br>*|
* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**536**
**Index**
## **Catalog Number Index**
|**Catalog**<br>**Page**<br>**Number**||**Catalog**<br>**Page**<br>**Number**|**Catalog**<br>**Page**<br>**Number**|**Catalog**<br>**Page**<br>**Number**|**Catalog**<br>**Page**<br>**Number**|
|---|---|---|---|---|---|
|WKFHO<br>115<br>WKH<br>*<br>WKJ<br>*<br>WKK<br>*<br>WKL<br>*<br>WKLSJ<br>116<br>WKMSJ<br>115-116<br>WKNHO<br>115<br>WKS<br>*<br>WKU<br>*<br>WKV<br>*<br>WLF<br>*<br>WMB<br>*<br>WMM<br>*<br>WMQ<br>*<br>WPQ<br>*<br>WQN<br>*<br>WQP<br>*<br>WSE<br>*<br>WSH<br>*<br>WSL<br>*<br>WSM<br>*<br>WSQ<br>*<br>WST<br>*<br>WSU<br>*<br>WTJ<br>*<br>WTK<br>*<br>WTT<br>*<br>WTZ<br>*<br>WUE<br>*<br>WUG<br>*<br>WUH<br>*<br>WUI<br>*<br>WUQ<br>*<br>WUR<br>*<br>WUU<br>*<br>WUV<br>*<br>WUW<br>*<br>WUY<br>*<br>WVA<br>*<br>WVQ<br>*<br>WVR<br>*<br>WWD<br>*<br>WWE<br>*<br>WWG<br>*<br>WWI<br>*<br>WWK<br>*<br>WWU<br>*<br>WWV<br>*<br>WWX<br>*<br>WYM<br>*<br>WZC<br>*<br>WZJ<br>*<br>WZK<br>*||WZX<br>*<br>XL25X<br>*<br>XL50F<br>*||||
* Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**537**
**Sales & Support**
## **Sales Support & Manufacturing Facilities**
## **North America**
## **Bussmann Business Headquarters**
114 Old State Road Ellisville, Missouri 63021 Telephone: 636-527-3877 Fax: 800-544-2570 Email: fusebox@cooperindustries.com
## **Asia**
## **Cooper Electric (Shanghai) Co. Ltd.**
955 Shengli Road Heqing Pudong, Shanghai 201201 China Telephone: 8621-2899-3888 Fax: 8621-2899-3997
## **Bussmann India**
## **Bussmann Mexico**
Poniente 148 #933 Col. Industrial Vallejo Azcapotzalco C.P. 02300, Mexico D.F. Telephone: +52-5587-0211 Ext.720 01-800-8-FUSEMX (387369) Fax: +52-55-5567-1131 E-mail: ventasbussmannmexico@cooperindustries.com
Bussmann, India, Pvt. Ltd. 2, EVR Street, Sedarpet Indl. Estate, Pondicherry – 605 111 India Telephone: 91-413-267-2005 Fax: 91-413-267-8182 E-mail: sales.india@cooperindustries.com
## **Europe**
## **Bussmann Transportation**
10955 SW Avery St. Tualatin, OR 97062 Telephone: 503-692-5360 Fax: 503-692-9091 E-mail: SurePower.Sales@cooperindustries.com
## **Bussmann Electronics**
1225 F Broken Sound Parkway NW Boca Raton, FL 33487 Telephone: 561-988-4100 Fax: 561-241-6640 E-mail: customerservice@cooperindustries.com
**Cooper (UK) Ltd.** Melton Road Burton-on-the-Wolds Leicestershire LE12 5TH England Telephone: 44-1509-882737 Fax: 44-1509-882786 E-mail: bule.sales@cooperindustries.com
## **South America**
**Bussmann Brazil**
Bussmann do Brasil Ltda. Rodovia Santos Dumont, km 23 13.300-000, Caixa Postal 095 Itu Sao Paulo Brazil Telephone: 55-11-4024-8400 Fax: 55-11-40-24-8424
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**538**
**NOTES**
## **Notes**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**539**
**Notes**
## **Notes**
For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
**540**
**Cross Reference & Low-Peak™ Upgrade**
## Bussmann Fuse Cross Reference & Low-Peak[[™]] Upgrade
**==> picture [512 x 623] intentionally omitted <==**
**----- Start of picture text -----**<br>
Class J Class L<br>Reference & Low-Peak [[™]] Existing Fuse Low-Peak [™] Upgrade Existing Fuse Low-Peak [™] Upgrade<br> A4J LPJ_SP A4BQ KRP-C_SP<br> AJT A4BT<br>Upgrade [EF CJ [- A4BY<br>Et _ -<br>CJS A4BY (type 55)<br>The left column represents Bussmann and - GF8B z - CLASS L<br>[J : [--<br>competitors’ part numbers. The right column HRCXXJ CLF<br>represents the Bussmann upgrades. J CLL<br>JA CLU<br>The Bussmann fuse upgrade offers superior JCL HRC-L<br>Et JDL Le {[-—————— KLLU =<br>performance while reducing the number of SKUs JFL KLPC<br>[- -<br>that need to be in stock. Low-Peak [™] fuses feature a - JHC - KLU<br>JKS KTU<br>high degree of current limitation, which will provide J JLS - L<br>[EF -<br>the best component protection and may reduce the JTD LPJ_SP LCL<br>r -<br>arc flash hazard. Listings are alpha-numerical by LCU KRP-C_SP<br>fuse class and fuse catalog symbol.<br>250 Volt Class R 600 Volt Class R<br>This list is only a consolidated cross reference to<br>some of our most common products. For a much Existing Fuse Low-Peak [™] Upgrade Existing Fuse Low-Peak [™] Upgrade<br> A2D LPN-RK_SP A6D LPS-RK_SP<br>more extensive database please consult the Product Et A2D-R [- A6K-R<br>- -<br>Profiler competitor cross-reference. Just visit [- A2K - A6X (type 1)<br>www.cooperbussmann.com and click on the JEt A2K-R A2Y (type 1) [-- ATCHRS-DE in<br>magnifying glass icon in the upper right corner. AT-DE CTS-R<br>[EF CHG - DES |<br>Et - |<br>Class CC and Midget CRN-R (type 3) DES-R<br>CTN-R DLS<br> Existing Fuse Low-Peak [™] Upgrade DEN DLS-R<br>ee Oe [- - _— 3a<br> A6Y (type 2B) LP-CC DLN ECS-R<br> ABU DLN-R ERS<br>J [EF -<br> AGU ECN FLS<br> ATDR ECN-R FLS-R<br> ATM ERN FRS<br> ATMR FLN FRS-R<br>TT ATQ F—d es FLN-R e # -— FTS-R ! hd<br> BAF FRN GDS<br> BAN FRN-R HA<br> BLF FTN-R KLS-R<br> BLN GDN KOS<br>CCMR HAC-R KTS-R<br>CM HB LES<br>CMF KLN-R LES-R<br>CNM KON LES-RK<br>CNQ KTN-R LKS<br>CTK LENRK LLS-RK<br>CTK-R LKN LOS-RK<br> FLM LLN-RK NLS<br> FLQ LON-RK NOS<br> FNM NCLR NRS<br> FNQ NLN OTS<br>GGU NON RES<br>a, HCLR (4) | EF- NRN --— RFS cs<br> KLK OTN RHS<br> KLK-R REN RLS<br>[Et - - )<br> KTK RFN SCLR<br> KTK-R RHN TRS<br>- Et - &<br> MCL RLN TRS-R<br> MEN TR 656<br>- es - ee<br> MEQ 655 10KOTS<br>- Et [-<br> MOF 660 50KOTS LPS-RK_SP<br>- - TT<br> MOL 10KOTN<br>J [-<br>OTM 50KOTN LPN-RK_SP<br>——_———- TRM CJ<br>|—sdCY 6JX LP-CC<br>The comparative catalog numbers shown were derived from the latest available published information from various manufacturers.<br>*FNQ-R suggested on primary of control transformers. Because competitors’ products may differ from Bussmann products, it is recommended that each application be checked for required<br> ATQR<br>electrical and mechanical characteristics before substitutions are made. Bussmann is not responsible for misapplications of our products.<br> FNQ-R FNQ-R<br>-- Overcurrent protection is application dependent. Consult the latest catalogs and application literature, or contact our Application<br> KLDR<br>Engineering Department toll free at 855-287-7626 (855-BUSSMANN).<br>**----- End of picture text -----**<br>
For product Data Sheets, visit www.cooperbussmann.com/DatasheetsEle
## **Customer Assistance**
## **Customer Satisfaction Team**
Available to answer questions regarding Bussmann products & services Monday-Friday, 7:00 a.m. – 6:00 p.m. Central Time. Contact:
## **Application Engineering**
Application support is available Monday-Friday,
## **Emergency and After-Hours Orders**
## **Online Resources** Visit resources:
## current rating
## **C3 – the Enhanced, Online Cooper Customer Center**
**Eaton’s Bussmann Business** PO Box 14460 St. Louis, MO 63178-44602 www.bussmann.com
## **Your authorized distributor is:**
**Eaton** 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com © 2013 Eaton All Rights Reserved Eaton is a registered trademark. Printed in USA Publication No.1007 All other trademarks are property August 2013 of their respective owners.
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 420,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →