Safety Relay, 24 VDC, DPST, SPST-NC, BH 5928 Series, DIN Rail, 3 A, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DOLD
- Product type: Safety Relays
- Coil Voltage:24VDC; Contact Configuration:DPST, SPST-NC; Product Range:BH 5928 Series; Relay Mounting:DIN Rail; Contact Current:3A; Relay Terminals:Screw; Contact Voltage AC Nom:
- IP Rating: IP20, IP40
- Coil Voltage: 24VDC
- Product Range: BH 5928 Series
- Relay Mounting: DIN Rail
- Contact Current: 3A
- Relay Terminals: Screw
- Contact Material: -
- Contact Configuration: DPST, SPST-NC
- Contact Voltage AC Nom: 230V
- Contact Voltage DC Nom: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 454.87 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Safety technique** **Emergency Stop Module BH 5928, BI 5928 with time delay safemaster** **==> picture [5 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> 0226419<br>**----- End of picture text -----**<br> According to EU directive for machines 98/37/EG According to IEC 204, EN 60204, DIN VDE 0113-1, EN 954-1 Safety category 4 according to DIN EN 954-1 Output: 3 NO or 2 NO, 1 NC instantaneous contacts and 3 NO release delayed contacts Single and 2-channel operation Line fault detection on On-button, when On-button is connected to S33-S34 Manual restart with button on S33-S34 or automatic restart with bridge between S13-S14 With or without cross fault monitoring in the E-stop loop LED indication for supply, channel 1/2 and release delayed contacts Removable terminal strips Wire connection: also 2 x 1,5 mm[2] stranded ferruled (isolated), DIN 46 228-4 or ## **Function diagram** 2 x 2,5 mm[2] stranded ferruled DIN 46 228-1/-2/-3 Width BH 5928: 45 mm BI 5928: 67,5 mm ~~a~~ **Approvals and marking** * * cL BH5928 approved ET Canada / USA BI 5928 pending ## **Applications** Protection of people and machines Emergency stop circuits on machines Monitoring of safety gates Stop category 1 can be realised ## **Indication** upper LED: on, when supply connected lower LEDs: on, when relay K1 and K2 resp. K1t and K2t energized ## **Notes** To select automatic restart terminals 13 - 14 must be bridged. Open terminals 13 - 14 select manual restart, the On-button must then be connected to S33 - S34. Line fault detection on On-button: The line fault detection is only active when S12 and S22 are switched simultaneously. If the On-button is closed before S12, S31, S32 is connected to voltage (also when line fault across On-button), the output contacts will not close. A line fault across the On-button which occurred after activation of the relay, will be detected with the next activation and the output contacts will not close. If a line fault occurs after the voltage has been connected to S12, S31, S32, the unit will be activated because this line fault is similar to the normal On-function. The unit can be operated with single channel and 2-channel operation with cross fault monitoring. For connection please refer to application examples. ## **Block diagram** **==> picture [329 x 170] intentionally omitted <==** **----- Start of picture text -----**<br> A1 A2<br>(+) (-) S11(+) S12 S31 S13S22S32 S33 S14 S34 Y39 Y40 13 23 31 47 57 67<br>‘uatih Opis 2 ities =O-0O-O 0 —0— [OF] [OO] = 0-0 eS OO ——— Ooms<br>]<br>K1 K1t<br>Overvoltage and Timer<br>short circuit prot. Monitoring logic release delay<br>K2 K2t<br>24V K1 K2 K1t K2t<br>I Netz K1 V K2 V K1t K2t I<br>fd i "W id iv<br>lw.dweeeee nema dD: _._.l<br>S21(-) 14 24 32 48 58 68<br>M7072_c<br>**----- End of picture text -----**<br> ~~——_—nnnnn~~ All technical data in this list relate to the state at the moment of edition. We reserve the right ~~eer ee~~ for technical improvements and changes at any time. 1 BH 5928, BI 5928 / 12.07.02 d BH 5928, BI 5928 / 12.07.02 d 1 ## **Circuit diagrams** **==> picture [202 x 462] intentionally omitted <==** **----- Start of picture text -----**<br> 13 23 33 41 57<br>A1<br>S31 S32 [S11]<br>(+) (+) [S12 S13 S14]<br>A1(+) S11 13 23 33 41 57<br>S12<br>S13<br>K1<br>S14<br>S22<br>K1t<br>S31<br>S32<br>S33<br>K2<br>S34<br>Y39<br>K2t<br>Y40<br>A2(-) S21 14 24 34 42 58<br>S21 A2<br>Y39 Y40 (-) [S22 S33] [S34] (-) M7277_b<br>14 24 34 42 58<br>BH 5928.47<br>13 23 31 47 57 67<br>A1<br>S31 S32 [S11]<br>(+) (+) [S12 S13 S14]<br>A1(+) S11 13 23 31 47 57 67<br>S12<br>S13<br>K1<br>S14<br>S22<br>K1t<br>S31<br>S32<br>S33<br>K2<br>S34<br>Y39<br>K2t<br>Y40<br>A2(-) S21 14 24 32 48 58 68<br>S21 A2<br>Y39 Y40 (-) [S22 S33] [S34] (-) M7278_c<br>14 24 32 48 58 68<br>BH 5928.92<br>**----- End of picture text -----**<br> **==> picture [201 x 194] intentionally omitted <==** **----- Start of picture text -----**<br> A1<br>(+) 13 23 37 47<br>S31 S32 [S11] S12 S13 S14<br>(+)<br>A1(+) S11 13 23 37 47<br>S12<br>S13<br>S14 K1<br>S22 K1t<br>S31<br>S32<br>S33<br>S34 K2<br>Y39 K2t<br>Y40<br>A2(-) S21 14 24 38 48<br>Y39 Y40 [S21] (-) S22 S33 S34 M8076<br>A2<br>14 24 38 48 (-)<br>**----- End of picture text -----**<br> **==> picture [44 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> BH 5928.91<br>**----- End of picture text -----**<br> **==> picture [200 x 214] intentionally omitted <==** **----- Start of picture text -----**<br> 13 23 33 47 57 67<br>A1<br>S31 S32 [S11]<br>(+) (+) [S12 S13 S14]<br>A1(+) S11 13 23 33 47 57 67<br>S12<br>S13<br>K1<br>S14<br>S22<br>K1t<br>S31<br>S32<br>S33<br>K2<br>S34<br>Y39<br>K2t<br>Y40<br>A2(-) S21 14 24 34 48 58 68<br>S21 A2<br>Y39 Y40 (-) [S22 S33] [S34] (-) M7279_c<br>14 24 34 48 58 68<br>**----- End of picture text -----**<br> BH 5928.93 2 ## **Circuit diagrams** **==> picture [200 x 194] intentionally omitted <==** **----- Start of picture text -----**<br> 13 23 33 41 57<br>A1 A2 S31 S32 [S11] [S13 S14]<br>(+) [S12]<br>A1 S11 13 23 33 41 57<br>S12<br>S13<br>S14 K1<br>S22 K1t<br>S31<br>S32<br>S33<br>S34 K2<br>Y39 K2t<br>Y40<br>A2 S21 14 24 34 42 58<br>Y39 Y40 [S21] (-) [S22 S33 S34] M8081_a<br>14 24 34 42 58<br>**----- End of picture text -----**<br> BI 5928.47 **==> picture [202 x 208] intentionally omitted <==** **----- Start of picture text -----**<br> 13 23 31 47 57 67<br>A1 A2 S31 S32 [S11] [S13 S14]<br>(+) [S12]<br>A1 S11 13 23 31 47 57 67<br>S12<br>S13<br>S14 K1<br>S22 K1t<br>S31<br>S32<br>S33<br>S34 K2<br>Y39 K2t<br>Y40<br>A2 S21 14 24 32 48 58 68<br>Y39 Y40 [S21] (-) [S22 S33 S34] M8080_a<br>14 24 32 48 58 68<br>BI 5928.92<br>**----- End of picture text -----**<br> ## **Notes** The gold plated contacts of the BH 5928 mean that this module is also suitable for switching small loads of 1 mVA - 7 VA, 1 mW - 7 W in the range 0,1 - 60 V, 1 - 300 mA. The contacts also permit the maximum switching current. However since the gold plating will be burnt off at this current level, the device is no longer suitable for switching small loads after this. The terminal S21 permits the operation of the device in IT-systems with insulation monitoring, serves as a reference point for testing the control voltage and is used to connect the E-stop loop when cross fault monitoring is selected. Connecting the terminal S21 to the protective ground bridges the internal short-circuit protection of Line A2(-). The short-circuit protection of line A1(+) remains active. Y39 - Y40 must be closed to have timed outputs. By opening the bridge between Y39 and Y40 the time delay can be interrupted immediately. Without bridge the contacts switch without delay. The time setting has to be sealed by the user after test. **==> picture [201 x 194] intentionally omitted <==** **----- Start of picture text -----**<br> 13 23 33 47 57 67<br>A1 A2 S31 S32 [S11] [S13 S14]<br>(+) [S12]<br>A1 S11 13 23 33 47 57 67<br>S12<br>S13<br>S14 K1<br>S22 K1t<br>S31<br>S32<br>S33<br>S34 K2<br>Y39 K2t<br>Y40<br>A2 S21 14 24 34 48 58 68<br>Y39 Y40 [S21] (-) [S22 S33 S34] M8079_a<br>14 24 34 48 58 68<br>**----- End of picture text -----**<br> BI 5928.93 ## **Technical data** ## **Input** **Nominal voltage UN:** BH 5928: DC 24 V, AC/DC 24 V BI 5928: AC 110 V, 230 V **Voltage range:** AC 0,85 ... 1,1 UN DC AC/DC at 10% residual ripple: 0,9 ... 1,1 UN 0,95 ... 1,1 UN at 48% residual ripple: 0,8 ... 1,1 UN 0,8 ... 1,1 UN **Nominal consumption:** AC approx. 6,0 VA DC approx. 3,5 W **Nominal frequency:** 50 / 60 Hz **Min. Off-time:** 1 s **Control voltage on S11:** DC 23 V at UN **Control current over S12, S32:** 40 mA at UN each **Min. voltage on S12, S32:** DC 21 V when relay activated **Short-circuit protection:** Internal PTC **Overvoltage protection:** Internal VDR 3 **Technical data** **Output** EN 60 068-1 ## **Technical data** ## **Contacts** 3 NO, 1 NC contacts instantaneous and BH 5928.47, BI 5928.47: 1 NO contact release delayed 2 NO contacts instantaneous, and BH 5928.91: - 2 NO contacts release delayed 2 NO, 1 NC contacts instantaneous and BH 5928.92, BI 5928.92: 3 NO contacts release delayed 3 NO contacts instantaneous and 3 NO contacts release delayed BH 5928.93, BI 5928.93: **Operate delay typ. at UN:** Manual start: Automatic start: 40 ms 500 ms **Release delay typ. at UN:** Disconnecting the supply: Disconnecting S12, S22, S31 and S32: **Time delay tv** (release delayed): 40 ms ## 15 ms Auxilary supply must be connected for time delay Time ranges: 0,1 ... 1 s 3,0 ... 30 s 0,3 ... 3 s 6,0 ... 60 s 0,5 ... 5 s 30 ... 300 s 1,0 ... 10 s Other ranges or values on request Fixed values: 1 s, 3 s, 5 s, 10 s, 300 s � 1 % of setting value positive guided AC 250 V **Repeat accuracy: Contact type: Nominal output voltage:** DC: see limit curve for arc-free operation DC: see limit curve for arc-free operation � 100 mV **Max switching current: Switching of low loads:** (Contact 5 � Au) � 1 mA **Thermal current Ith:** in 1 contact path: max. 5 A **Switching capacity** to AC 15 NO contact: AC 3 A / 230V EN 69 947-5-1 NC contact AC 2 A / 230 V EN 60 947-5-1 to DC 13: AC 8 A / 24 V EN 60 947-5-1 **Electrical life** to AC 15 at 2 A, AC 230 V: 10[5] switching cycles EN 60 947-5-1 **Permissible operating frequency:** max. 1200 switching cycles / h max. 1200 switching cycles / h with manual restart and short release delay time **Short circuit strength** max. fuse rating: 6 A gL EN 60 947-5-1 line circuit breaker: C 8 A **Mechanical life:** 10 x 10[6] switching cycles ## **General data** **Operating mode:** Continuous operation **Temperature range:** - 15 ... + 55 � C **Clearance and creepage** **distances** overvoltage category / contamination level: 4 kV / 2 IEC 60 664-1 **EMC** Electrostatic discharge: 8 kV (air) EN 61 000-4-2 HF irradiation: 10 V / m EN 61 000-4-3 Fast transients: 2 kV EN 61 000-4-4 Surge voltages between wires for power supply: 1 kV EN 61 000-4-5 between wire and ground: 2 kV EN 61 000-4-5 HF-line-conducted: 10 V EN 61 000-4-6 Interference suppression: Limit value class B EN 55 011 **Degree of protection:** Housing: IP 40 EN 60 529 Terminals: IP 20 EN 60 529 **Housing:** Thermoplastic with V0 behaviour according to UL subject 94 **Vibration resistance:** Amplitude 0,35 mm EN 60 068-2-6 frequency 10 ... 55 Hz **Climate resistance: Terminal designation: Wire connection:** 15 / 055 / 04 EN 50 005 1 x 4 mm[2] solid or 1 x 2,5 mm[2] stranded ferruled (isolated) or 2 x 1,5 mm[2] stranded ferruled (isolated) DIN 46 228-1/-2/-3/-4 or 2 x 2,5 mm[2] stranded ferruled DIN 46 228-1/-2/-3 Box terminal with wire protection, removable terminal strips DIN rail EN 50 022 400 g **Wire fixing:** **Mounting: Weight:** ## **Dimensions** **Width x height x depth:** BH 5928: 45 x 84 x 118 mm BI 5928: 67,5 x 84 x 118 mm ## **Standard type** BH 5928.93 DC 24 V 0,5 ... 5 s Article number: 0050369 � Output: 3 NO contacts instantaneous and 3 NO contacts release delayed � : DC 24 V - Nominal voltage UN: - Time delay tv: 0,5 ... 5 s - � Width: 45 mm ## **Variants** with fix time delay fixed times: 1 s, 3 s, 5 s, 10 s, 300s other times on request with absolute time scale time ranges: 0,3 ... 3 s, 3 ... 30 s contact fusing 6 A fast, 4 A slow for DC 24 V BH 5928._ _/001: BH 5928.91/002: ## **Ordering example for variants:** B_ 5928. _ _ / _ _ _ AC/DC 24 V 50/60 Hz 1 ... 10 s 0,1 ... 1 s 0,3 ... 3 s 0,5 ... 5 s 1 ... 10 s 30 ... 300 s for fixed time end of scale value, other ranges on request only for AC/DC at BH 5928: DC 24 V at BI 5928: AC 230 V /000 standard, not stated in type number (for settable time ranges) /001 fixed time .47 = 3 NO contacts, - 1 NC contact instantaneous and 1 NO contact release delayed .91 = 2 NO contacts instantaneous and 2 NO contacts release delayed (only at BH 5928) .92 = 2 NO contacts, - 1 NC contact instantaneous and 3 NO contacts release delayed .93 = 3 NO contacts instantaneous and 3 NO contacts release delayed H: width 45 mm I: width 67,5 mm 4 **==> picture [529 x 217] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristics<br>250<br>200<br>150<br>100<br>50<br>0<br>1 2 3 4 5 6 7 8<br>Switching current I[A]<br>safe breaking, no continuous arcing<br>under the curve, max. 1 switching cycle/s<br>V]<br>Switching voltage U [<br>M 7073_a<br>**----- End of picture text -----**<br> Arc limit curve for resistive load Quadratic total current limit curve ## **Application examples** **==> picture [259 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>(+)<br>Off<br>On E-stop<br>A1(+) [S11] S33 S34 S12 S31 S32 13 .. ..<br>BH5928, BI5928<br>A2(-) S21 S22 Y39 Y40 14 .. ..<br>N<br>(-) M7074_a<br>**----- End of picture text -----**<br> Single channel emergency stop circuit. This circuit does not have any redundancy in the emergency-stop control circuit **==> picture [260 x 176] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>(+)<br>E-stop<br>On K4<br>K5<br>A1(+) S11 S33 S34 S31 S32 13 23 ..<br>BH5928, BI5928<br>A2(-) S21 S22 Y39 Y40 14 24 ..<br>K4 K5<br>N<br>(-) M7077_a<br>**----- End of picture text -----**<br> Contact reinforcement by external contactors, 2-channel controlled. The output contacts can be reinforced by external contactors with positive guided contacts for switching currents > 5 A. Functioning of the external contactors is monitored by looping the NC contacts into the closing circuit (terminals S13-S14 or S33-S34) **==> picture [529 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> L1 L1<br>(+) (+)<br>E-stop E-<br>stop<br>S1 On<br>A1(+) S11 S13 S14 S31 S32 Y39 Y40 13 .. .. A1(+) [S31] S33 S34 S32 S22 S21 13 .. ..<br>BH5928, BI5928 BH5928, BI5928<br>A2(-) S21 S22 14 [..] [..] A2(-) S11 S12 Y39 Y40 14 .. ..<br>N<br>N (-) M7078_a<br>(-) M7075_a<br>**----- End of picture text -----**<br> 2-channel emergency stop circuit with cross fault detection 2-channel emergency stop circuit without cross fault monitoring autostart and interruption of time by S1 5 ## **Application examples** **==> picture [259 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>(+)<br>E-stop<br>On K4<br>K5<br>A1(+) [S11] S33 S34 S31 S32 13.. ..<br>BH5928, BI5928<br>A2(-) S21 S22 Y39 Y40 14 .. ..<br>K4 K5<br>N<br>(-) M7076_b<br>**----- End of picture text -----**<br> Contact reinforcement by external contactors controlled by one contact path. **==> picture [260 x 181] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>(+)<br>Sliding guard closed<br>S1<br>On<br>S2<br>A1(+) S11 S33 S34 S12 S32 13 .. ..<br>BH5928, BI5928<br>A2(-) S21 S22 Y39 Y40 14 .. ..<br>N<br>(-) activated No contact M7079_a<br>(contact position: closed)<br>**----- End of picture text -----**<br> 2-channel safety gate monitoring **E. DOLD & SÖHNE KG • D-78114 Furtwangen** • Postf. 1251 • Tel. +49 7723 654 0 • Telefax +49 7723 654 356 e-mail dold-relays@t-online.de • internet http://www.dold.com 6
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →