BD 5987.02/001 AC 50/60HZ 230V
Safety Relay, 230 VAC, DPST, BD 5987 Series, DIN Rail, 5 A, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DOLD
- Product type: Safety Relays
- Coil Voltage:230VAC; Contact Configuration:DPST; Product Range:BD 5987 Series; Relay Mounting:DIN Rail; Contact Current:5A; Relay Terminals:Screw; Contact Voltage AC Nom:230V; Contact Vol
- IP Rating: IP20, IP40
- Coil Voltage: 230VAC
- Product Range: BD 5987 Series
- Relay Mounting: DIN Rail
- Contact Current: 5A
- Relay Terminals: Screw
- Contact Material: -
- Contact Configuration: DPST
- Contact Voltage AC Nom: 230V
- Contact Voltage DC Nom: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 246.79 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Safety technique** **Emergency stop module BD 5987 safemaster** ## BD 5987.02: - According to EC Directive for machines 98/37/EG - According to IEC/EN 60204-1 - Safety category 4 according to EN 954-1 - Output: 2 NO contacts for AC 250 V - Gold-plated contacts to switch small loads (input for PLC) - 1-channel or 2-channel connection - Line fault detection at On pushbutton - Operating state display - LED displays for channels 1 and 2 - Overvoltage and short circuit protection - Wire connection: also 2 x 1,5 mm[2] stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or - 2 x 2,5 mm[2] stranded ferruled DIN 46 228-1/-2/-3 - Width 45 mm **Fucntion diagram** BD 5987.--/001: as BD 5987.02 but • Optionally automatic On function when operating voltage is applied or after activation by the On pushbutton • Optionally cross fault detection in emergency stop circuit **Approvals and marking** * ET Canada Canada / USA * see variants ~~B/E paueice~~ **Applications** **==> picture [527 x 545] intentionally omitted <==** **----- Start of picture text -----**<br> Pushbutton applied or after activation by the On pushbutton<br>On • Optionally cross fault detection in emergency stop circuit<br>Emergency- Approvals and marking<br>stop (Off)<br>* *<br>K2<br>ET Canada Canada / USA * see variants<br>K3 * Short-circuit detection<br>= at the On pushbutton B/E paueice<br>Applications<br>M 6742<br>Protection of people and machines<br>• Emergency stop circuits on machines<br>Block diagram • Monitoring of safety gates<br>A1(+)A2(-) S33 S33 S33 PE(-) Y2 S12 S12 S22 13 23 33 Indication<br>LED power supply: on when operating voltage present<br>LED K2: on when supply on K2<br>LED K3: on when supply on K3<br>overvoltage and short- K2 K3 monitoring<br>circuit protection logic K2 Notes<br>&<br>K1 Line fault detection at the On pushbutton:<br>The output contacts cannot be closed if the On pushbutton is already<br>24V K1 K2 K3 closed before the voltage is applied to S12, S22 (also in the event of a line<br>power K3 fault at the On pushbutton).<br>A line fault at the On pushbutton which occurs after activation of the<br>device is recognized when switching- on takes place again and closing<br>of the output contacts is then prevented.<br>If a line fault occurs at the On pushbutton after the voltage is already<br>present at S12, S22 undesired activation will take place, because this line<br>S34 Y1 S23 14 24 34<br>fault does not differ from the normal closing function.<br>Circuit diagrams<br>A1 PE A1 S21 A1<br>(+) 13 23 S22 S33 (-) Y1 Y2 (+) 13 23 S12 /PE S22 S23 S33 (+) 13 23<br>A1 Y1 13 23 A1 X5 13 23 A1 13 23<br>S12 S12<br>S22 K2 S22 K2 T33 K2<br>S33 S33 T34<br>S34 K3 S34 K3 K3<br>A2 Y2 PE 14 24 A2 X6 PE 14 24 A2 14 24<br>A2 A2 A2<br>14 24 S12 S12 S33 S33 S34 (-) 14 24 S12 S33 X5 X6 S34 (-) 14 24 T33 T34 (-)<br>BD 5987.02 M7375_b BD 5987.02/001 M7376_b BD 5987.02/101 M7377_b<br>A1 S21 A1 S21 A1<br>13 23 S12 S22 S23 S33 13 21 S12 S22 S23 S33 13 23 T12 PE T22 S23 T11<br>(+) /PE (+) /PE (+)<br>A1 X5 13 23 33 A1 X5 13 21 A1 T11 13 23 33<br>S12 S12 T12<br>S22 K2 S22 K2 T22 K2<br>S33 K1 S33 T33 K1<br>S34 K3 S34 K3 T34 K3<br>A2 X6 PE 14 24 34 A2 X6 PE 14 22 A2 X6 PE 14 24 34<br>A2 A2 A2<br>14 24 33 34 X5 X6 S34 (-) 14 22 S12 S33 X5 X6 S34 (-) 14 24 33 34 T33 X6 T34 (-)<br>BD 5987.03/001 M7378_b BD 5987.16/001 M7380_b BD 5987.03/021 M7379_c<br>M6758_a<br>**----- End of picture text -----**<br> The output contacts cannot be closed if the On pushbutton is already closed before the voltage is applied to S12, S22 (also in the event of a line fault at the On pushbutton). A line fault at the On pushbutton which occurs after activation of the device is recognized when switching- on takes place again and closing of the output contacts is then prevented. If a line fault occurs at the On pushbutton after the voltage is already present at S12, S22 undesired activation will take place, because this line fault does not differ from the normal closing function. All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. BD 5987 / 08.05.06 e 1 10 x 10[6] switching cycles **Mechanical life:** ## **Notes** The gold-plated contacts of the BD 5987 mean that this module is also suitable for switching small loads of 1 mVA ... 7 VA, 1 mW ... 7 W in the range 0,1 ... 60 V, 1 ... 300 mA. The contacts also permit the maximum switching current. However, since the gold plating will be burnt off at this current level, the device is no longer suitable for switching small loads after this. The PE terminal permits operation of the device in IT systems with insulation monitoring and also serves as a reference point for testing the control voltage. The internal short-circuit protection will be bridged on DC devices, if the protective ground is connected to terminal PE. One or more extension modules BN 5989 or external contactors with positively-driven contacts may be used to multiply the number of contacts of the emergency stop module BD 5987. For automatic restart: S22 must be connected before S12. S12 initiates the automatic restart. With manual restart it is not necessary to follow this order. ## **ATTENTION - AUTOMATIC START!** According to IEC/EN 60 204-1 part 9.2.5.4.2 it is not allowed to restart automatically after emergency stop. Therefore the machine control has to disable the automatic start after emergency stop. ## **Technical data** ## **Input** **Nominal voltage UN:** AC 24, 48, 110, 127, 230, 240 V DC 24 V **Voltage range:** AC 0,8 ... 1,1 UN at 10% residual ripple: DC 0,9 ... 1,2 UN at 48% residual ripple: DC 0,8 ... 1,1 UN **Nominal consumption:** approx. 5,5 VA **Nominal frequency:** 50 / 60 Hz **Control voltage at S33:** DC 24 V **Control current** BD 5987.02: typ. DC 55 mA BD 5987.02/001: typ. DC 45 mA **Minimum voltage at terminals S12, S22:** DC 21 V with activated device **Recovery time:** 0,5 s after release of the emergency stop pushbutton ## **Output** ## **Contacts** BD 5987.02: 2 NO contacts BD 5987.16: 1 NO contact, 1 NC contact The NO contacts are safety contacts. **ATTENTION! The NC contacts 21-22 and the NO contact 33-34 can only be used for monitoring. Operate time:** max. 100 ms BD 5987.02/001: with automatic restart approx. 1 s ## **Technical data** ## **General data** |**Operating mode:**<br>**Temperature range:**|Continuous operation<br>- 15 ... + 55°C| |---|---| |**Clearance and creepage**<br>**distances**<br>overvoltage category /<br>contamination level:<br>**EMC**<br>Electrostatic discharge:<br>HF irradiation:<br>Fast transients:|at max. 90 % humidity<br>4 kV / 2<br>IEC 60 664-1<br>8 kV (air)<br>IEC/EN 61 000-4-2<br>10 V / m<br>IEC/EN 61 000-4-3<br>2 kV<br>IEC/EN 61 000-4-4| |Surge voltages<br>between|| |wires for power supply:|1 kV<br>IEC/EN 61 000-4-5| |between wire and ground:|2 kV<br>IEC/EN 61 000-4-5| |Interference suppression:|Limit value class B<br>EN 55 011| |**Degree of protection:**|Housing:<br>IP 40<br>IEC/EN 60 529| ||Terminals:<br>IP 20<br>IEC/EN 60 529| |**Housing:**|Thermoplastic with V0 behaviour| ||according to Ul subject 94| |**Vibration resistance:**|Amplitude 0,35 mm IEC/EN 60 068-2-6| |**Climate resistance:**|frequency 10 ... 55 Hz<br>15 / 055 / 04<br>IEC/EN 60 068-1| |**Terminal designation:**<br>**Wire connection:**|EN 50 005<br>1 x 4 mm2solid or| ||1 x 2,5 mm2stranded ferruled (isolated)<br>or| ||2 x 1,5 mm2stranded ferruled (isolated)<br>DIN 46 228-1/-2/-3/-4 or| ||2 x 2,5 mm2stranded ferruled<br>DIN 46 228-1/-2/-3| |**Wire fixing:**<br>**Mounting:**<br>**Weight:**|Plus-minus terminal scews<br>M3.5 box terminal with wire protection<br>DIN rail<br>IEC/EN 60 715<br>450 g| ## **Dimensions** **Width x height x depth:** 45 x 74 x 121 mm **Standard type** |BD 5987.02/001 DC 24 V||| |---|---|---| |Article number:|0040954|stock item| |• Output:|2 NO contacts|| - Optionally automatic On function when operating voltage is applied or after activation by the On pushbutton - Nominal voltage UN: DC 24 V - Width 45 mm **Release time** Opening in secondary circuit (S12-S22): 50 ms ± 25 % Opening in supply circuit BD 5987.02: 350 ms ± 50 % BD 5987.02/001: 120 ms ± 50 % **Contact type:** relay, positively-driven **Nominal output voltage:** AC 250 V DC: see limit curve for arc-free operation **Thermal current Ith:** see continuous current limit curve (max. 10 A in one contact path) **Switching capacity** to AC 15: 5 A / AC 230 V IEC/EN 60 947-5-1 for NO contact 2 A / AC 230 V IEC/EN 60 947-5-1 for NC contact **Electrical life:** to AC 15 at 2 A, AC 230 V: 10[5] switching cycles IEC/EN 60 947-5-1 **Permissible operating frequency:** 600 switching cycles / h **Short circuit strength max. fuse rating:** 6 A gL IEC/EN 60 947-5-1 2 ## **Application examples** ## **Variants** **==> picture [260 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>Emergency-<br>stop<br>On E - - -<br>A1(+) S34 S33 S33 S33 PE(-) Y2 S12 S12 S22 13 23<br>BD 5987<br>A2(-) Y1 14 24<br>N<br>M 6744<br>E- - - - - - - - - - - -<br>**----- End of picture text -----**<br> **BD 5987.02/60:** with CSA approval **BD 5987.02/61:** with UL approval (Canada/USA) **BD 5987.02/001:** Optionally cross fault monitoring on the emergency stop loop (see application M6749) Jumper asignment for functions: Activation via On pushbutton / or automatic On function On pushbutton Jumper Function S12-S34 or X5 - X6 S33-S34 The output contacts are switched only after operation of the On pushbutton. Line fault monitoring at the On pushbutton. Automatic On function for operating voltage Off/On or after emergencyM8687 stop release Two-channel emergeny stop circuit **==> picture [260 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>Off<br>Emergency-<br>On E - - - stop<br>A1(+) S34 S33 S33 S33 PE(-) Y2 S12 S12 S22 13 23<br>BD 5987<br>A2(-) Y1 14 24<br>N<br>M 6743<br>E - - -<br>- - - E- -<br>**----- End of picture text -----**<br> ## **BD 5987.03/001:** with 2 NO contacts, 1 signalling contact AC/DC 0,1 ... 1 A / 10 ...120 V **BD 5987.16/001** : with 1 NO contact, 1 NC contact **BD 5987.02/101** : see BD 5987.02/001, but with special terminal arrangement **BD 5987.03/201** : see BD 5987.03/001, but with special terminal designation ## Jumper asignment for functions: Activation via On pushbutton / or automatic On function On pushbutton Jumper Function T11-T34 or T33-X6 T12-T34 One-channel emergency stop circuit. This circuit does not have any redundancy in the emergency stop control circuit The output contacts are switched only after operation of the On pushbutton. **==> picture [259 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>N<br>Off<br>Emergency-<br>stop On E - - -<br>A1(+) S34 S33 S33 S33 PE(-) Y2 S12 S12 S22 13 23<br>BD 5987<br>A2(-) Y1 14 24<br>M 6745<br>E - - -<br>E- - - - - - - - - - - -<br>**----- End of picture text -----**<br> Line fault monitoring at the On pushbutton. Automatic On function for operating voltage Off/On or after emergencyM8687 stop release ## **Ordering example for Variants** BD 5987 .02 /_ _ _ AC 230 V 50/60 Hz Nominal frequency Nominal voltage Variant, if required Contacts Type Two-pole emergency stop circuit with emergency stop control device in supply circuit. Application for long emergency stop loops where the control voltage drops below the minimum voltage of 21 V. ## **Attention:** ## **Characteristics** Single faults (e.g. line faults at the emergency stop control device) are not detected with this external circuit configuration **==> picture [528 x 173] intentionally omitted <==** **----- Start of picture text -----**<br> I (A) 250 detected with this external circuit configuration<br>7<br>200 L1<br>6<br>5 150 Emergency-<br>K4 stop<br>4<br>3 100 On E - - - K5<br>2 50 A1(+) S34 S33 S33 S33 PE(-) Y2 S12 S12 S22 13 23<br>1 0<br>BD 5987<br>1 2 3 4 5 6 7 8 9 10<br>0 10 20 30 40 50 60 T (�C) Switching current I [A] A2(-) Y1 14 24<br>M 6732<br>Continuous current limit curve Limit curve for arc-free K4 K5<br>(Current via two contact rows) M6759 operation with resistive load N<br>M 6746<br>[V]<br>U<br>Switching voltage<br>E- - - - - - - - - - - -<br>**----- End of picture text -----**<br> Contact reinforcement by external contactors, 2-channel. The output contacts can be reinforced by external contactors with positively-driven contacts for switching currents > 10 A. Functioning of the external contactors is monitored by looping the NC contacts into the closing circuit (terminals Y2 - S12). 3 ## **Application examples** **==> picture [260 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>Emergency-<br>K4 stop<br>On E - - - K5<br>A1(+) S34 S33 S33 S33 PE(-) Y2 S12 S12 S22 13 23<br>BD 5987<br>A2(-) Y1 14 24<br>K4 K5<br>N<br>M 6747<br>E- - - - - - - - - - - -<br>**----- End of picture text -----**<br> Contact reinforcement by external contactors with reduced safety level **==> picture [260 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>safety gate<br>closed<br>S1<br>On E - - - S2<br>A1(+) S34 S33 S33 S33 PE(-) Y2 S12 S12 S22 13 23<br>BD 5987<br>A2(-) Y1 14 24<br>N<br>Activated NO contact<br>(contact position: closed) M6748_a<br>**----- End of picture text -----**<br> Two-channel monitoring of a safety gate **==> picture [260 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>Emergency-<br>stop E - - - - - - - - - - - - - - - - - - - - - - - - - - -<br>A1(+) 13 23 S12 S21,PE S22 S23 S33<br>BD 5987.02/001<br>14 24 S12 S33 X5 X6 S34 A2(-)<br>On E - - -<br>N<br>M 6749<br>**----- End of picture text -----**<br> Two-channel emergency stop circuit with cross fault detection. Activation via On pushbutton. ---- Jumper X5 -X6: Jumper X5 - X6 must be fitted for the automatic On function. The On pushbutton is not required **==> picture [260 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>Emergency-<br>stop E - - - - - - - - - - - - - - - - - - -<br>A1(+) 13 23 S12 S21,PE S22 S23 S33<br>BD 5987.02/001<br>14 24 S12 S33 X5 X6 S34 A2(-)<br>On E - - -<br>N<br>M 6750<br>**----- End of picture text -----**<br> Two-channel emergency-stop circuit without cross fault detection. Activation via On pushbutton. ---- Jumper X5 - X6: Jumper X5 - X6 must be fitted for the automatic On function. The On pushbutton is not required **E. DOLD & SÖHNE KG • D-78114 Furtwangen** ���������������������������������������������������������������� e-mail dold-relays@dold.com • internet http://www.dold.com 4
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →