Image not available
Illustrative purposes only
BA2R08MV1
Time Delay Relay, 0.5 s, 10 Days, Syrline BA2R Series, DPDT, 8 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET
- Product type: Time Delay Relays - Electromechanical
- Contact Voltage VDC:-; Time Min:0.5s; Time Max:10Days; Product Range:Syrline Series; Contact Configuration:DPDT; Contact Current:8A; Relay Mounting:DIN Rail; Contact Voltage VAC:
- SVHC: No SVHC (21-Jan-2025)
- Time Max: 10Days
- Time Min: 0.5s
- Product Range: Syrline BA2R Series
- Relay Mounting: DIN Rail
- Contact Current: 8A
- Relay Terminals: Screw
- Nom Input Voltage: 240VAC
- Timing Adjustment: Knob
- Contact Voltage VAC: 250V
- Contact Voltage VDC: -
- Approvals & Standards: CCC, CE, cULus
- Contact Configuration: DPDT
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 107.06 € |
| Current stock | 10+ |
| Lead time | 28 days |
## **BA2R** Timers Syrline 17.5 mm - 2 Relays 8A **==> picture [189 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||| |---|---|---|---|---|---|---|---| |›|Multi|-|voltage 12 →240 V AC/DC| |a|.| |›|LED status indicator (relay version)|LED|status|indicator|(relay version)| |›|Possibility of external load connection in parallel to the|Possibility| |control input|control|inputof external load connection|in parallel to the| |›|3|S|-|wire PNP sensor compatible|oh|oe|neces| **----- End of picture text -----**<br> **==> picture [464 x 432] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||| |---|---|---|---|---|---|---| |Specifications| |Functions|Delay|Output|Nominal rating|Connections|Supply voltage|Code| |A-At|0,1 s →10 days|2 changeover relays|2 x 8A|Screw terminals|12 →240 V ∿/⎓|BA2R08MV1| |Output relay| |Contact arrangement|2 CO (SPDT) (ChangeOver -Simple Pole Double Throw-)| |R1: Follow timing function| |R2: Follow timing function| |Maximum switching voltage|250 VAC/ 8 A resistive / 250 VDC / 0.3 A resistive| |Switching current rate (resistive)|NO / NC : 8A 250 V AC / 8 A 30 VDC @ 25°C| |NO / NC : 5A 250 V AC / 5 A 30 VDC @ 60°C| |Minimum switching contact|10 mA / 5 VDC| |Maximum switching power (resistive)|2000 VA / 80 W @ 25°C| |Electrical life|10|[5]|cycles min at 250 VAC/ 8 A resistive| |Maximum rate (at max switching power)|360 cycles /hour| |Mechanical life|10 x 10|[6]|cycles| |Rated impulse voltage|5 kV (1.2/50µs)| |Dielectric strength between coil / contacts|IEC 60664-1: 5 kV /1 min / 1 mA / 50 Hz| |Dielectric strength between open contacts|2.5 kV /1 min / 1 mA / 50 Hz| |Timing| |Timing ranges (7 ranges)|0.5→10s, 0.05→1min, 0.5→10min, 0.05→1h,| |0.5→10h, 0.05→1day, 0.5→10days| |Minimum pulse duration typically (relay version)|IEC 1812-1: 30 ms / 100 ms with load| |Maximum reset time by de-energisation typically (relay version)|IEC 1812-1: 120 ms| |Repeatability|IEC 1812-1: ≤ ± 0,5 %| |Repetition accuracy with constant parameters|IEC 1812-1: ≤ ± 10 %| |Drift Temperature|≤ ± 0.05 % / °C| |Voltage-dependent drift|≤ ± 0.2 % / V| |Supply| |Multi-voltage power supply|12→240 V∿/⎓| |Operating range|15 %, +10 %| |Operating frequency (Hz)|50 / 60 Hz ± 5 %| |Galvanic isolation|No| **----- End of picture text -----**<br> **I** Timers **I 02** **I** www.crouzet-control.com |Supply|Supply| |---|---| |Max. absorbed power|Approx. 3 VA (V∿) 1.5 W (V⎓)| |Immunity from micro power cuts|10 ms| ||| |General characteristics|| |Insulation voltage, IEC 60664-1|300 V| |Installation category (acc. to IEC/EN 60664-1)|Overvoltage category III ; pollution degree 2| |Impulse voltage CEI/EN 60664-1|4 kV (1,2 / 50 µs)| |Clearance / Creepage distances|IEC 60664-1: 3 mm / 3.2 mm| |Breakdown voltage|EN-61812-1: 2,5 kV / 1 min / 1 mA / 50 Hz| |Insulation resistance|NFC 93 050: > 500 MΩ / 250 V⎓ / 1min| |Status indication|Un: green LED blinks when count, continuous ON when supplied<br>R: yellow LED continuous ON when the relay is ON| |Casing|DIN 43880: 17,5 mm| |Fixing: Symmetrical DIN rail|EN 50022: 35 mm| |Mounting position|All positions| |Housing material|Enclosure plastic type UL94 - V0| |Protection (IEC/EN 60529)|Housing: IP40 / Terminal block: IP20| |Terminal capacity Single-wire without ferrule|IEC 60947-1<br>1 x 0.5 →3.3 mm² (AWG 20 →AWG 12)<br>2 x 0.5 →1.5 mm² (AWG 20 →AWG 16)| |Max. tightening torque (Nm)|IEC 60947-1<br>0,5 N.m / 4,4 lbf.in| |Operating temperature range (°C)|IEC 60068-2<br>-20 °C →+60 °C| |Storage temperature range (°C)|IEC 60068-2<br>-40 °C →+70 °C| |Relative humidity no condensation acc. to IEC/EN 60068-2-30|93 % without condensation| |Vibration resistance according to IEC/EN 60068-2-6|± 0.15 mm from 10 Hz →60 Hz 2g from 60 Hz →150 Hz| |Impact resistance|IEC 60068-2-27<br>15gn - 11ms ; 3 x 6 axis (output OFF)<br>5gn - 11ms ; 3 x 6 axis (Output ON)| |Drop to concrete floor|IEC 60068-2-32: igh: 0.75m| |Weight: casing 17,5 mm|70 g<br>80 g with packaging| |Directives|2014/30/EU: EMC<br>2014/35/EU: low voltage| |Certifications|CE - cULus Listed Industrial Control Equipment - CCC| |Conformity to standards|CEI 60664-1: Insulation coordination for equipment within<br>low-voltage systems<br>CEI 61812-1/ Specified time relays for industrial use<br>UL 60947-4-1/ Industrial Control Equipment (NRNT- Industrial<br>Control Switches)| |Conformity with environmental directives|2015/863/UE: RoHS<br>1907/2006: Reach<br>2012/19/UE: WEEE| |Electromagnetic compatibility IEC 61000-6-2, IEC 61000-6-3,<br>IEC 61000-6-4|Immunity for industrial environment<br>Emission residential environment<br>Emission industrial environment| |Electromagnetic compatibility - Immunity to electrostatic discharges<br>acc to IEC/EN 61000-4-2|Level III Air ± 8 KV / Contact ± 6 KV| |Immunity to radiated, radio-frequency, electromagnetic field acc.<br>IEC/EN 61000-4-3|Level III<br>10 V/m (80 M Hz to 1 G Hz) 80 % AM (1 k Hz)<br>3 V/m (1,4 →2 G Hz) 80 % AM (1K Hz)<br>1V/m (2 →2.7 G Hz) 80 % AM (1K Hz)| **I** Timers **I 03** **I** www.crouzet-control.com ## General characteristics **==> picture [467 x 230] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Immunity to rapid transient bursts acc. to IEC/EN 61000-4-4|Level III direct ± 2 kV (power supply) / capacitive coupling clamp| |± 1 KV (command input and outputs)| |Immunity to shock waves on power supply acc. to IEC/EN 61000-4-5|Level III| |line-to-earth ± 2 kV / line-to-line ± 1kV| |Immunity to radio frequency in common mode acc. to|Level III| |IEC/EN 61000-4-6|10 Vrms (0,15 →80 M Hz) 80 % AM (1 k Hz)| |Immunity to voltage dips and breaks acc. to IEC/EN 61000-4-11|Industrial Class II:| |0 % residual voltage during 1cycle a.c. power ports| |70 % residual voltage during 25/30 cycles a.c. power ports| |0 % residual voltage, 250/300 cycles a.c. power ports| |Residential:| |0 % residual voltage during 10 cycle a.c.power ports| |40 % residual voltage during 10 cycles a.c. power ports| |70 % residual voltage during 10 cycles a.c. power ports| |0 % residual voltage, 250/300 cycles a.c. power ports| |Mains-borne and radiated emissions acc. to EN 55022 (CISPR22),|EN 55022 / CISPR22 Class B (IT equipment)| |EN55011 (CISPR11)|EN 55011 / CISPR11 Class B, Group 1 (Medical equipment)| |Dimensions| **----- End of picture text -----**<br> **==> picture [461 x 267] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Curves| |Function A|U| |Delay on energisation 1 relay| |R1/R2| |R2| |T| |Function At|U| |Timing on Energisation with memory| |Y1| |R1/R2| |t1|t2| |T = t1+t2| |Connections| |1 changeover relay output| |U| |+| |A1|Y1|15|25| |R1|R2| |A2| |16|18|26|28| |c|e| |igiele!|Zs|L| **----- End of picture text -----**<br>
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →