Time Delay Relay, 30 V, 0.5 s, 10 Days, Syrline BA1R Series, SPDT, 16 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET
- Product type: Time Delay Relays - Electromechanical
- Contact Voltage VDC:30V; Time Min:0.5s; Time Max:10Days; Product Range:Syrline Series; Contact Configuration:SPDT; Contact Current:16A; Relay Mounting:DIN Rail; Contact Voltage V
- SVHC: No SVHC (21-Jan-2025)
- Time Max: 10Days
- Time Min: 0.5s
- Product Range: Syrline BA1R Series
- Relay Mounting: DIN Rail
- Contact Current: 16A
- Relay Terminals: Screw
- Nom Input Voltage: 240VAC
- Timing Adjustment: Knob
- Contact Voltage VAC: 250VAC
- Contact Voltage VDC: 30V
- Approvals & Standards: CCC, CE, cULus
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 80.38 € |
| Current stock | 10+ |
| Lead time | 28 days |
## **BA1R** Timers Syrline 17.5 mm - 1 Relay 16A › Multi Multi ~~-~~ - function or mono function or mono- ~~f -~~ function unction › Multi Multi. ~~-~~ - range (12 function) range (12lanefunction)oy › Multi ~~-~~ voltage 12 →240 V AC/DC Multi ~~-~~ voltage 12 240 V AC/DC › LED status indicator (relay version) LED status indicator (relay version) › Possibility of external load connection in parallel to the Possibility of external load connection in parallel to the control input › 3 co3 ~~n~~ wire wire PNP sensor compatible trol PNPinput sensor compatible |Specifications|Specifications|||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Functions<br>Delay|||Output||Nominal rating|||Nominal rating<br>Connections|||Supply voltage|||Code| |A-At|0,1 s →10 days|0,1 s →10 days|1 changeover relay||16 A||||Screw terminals||12 →240 V ∿/⎓|||BA1R16MV1| |||||||||||||||| |Output relay||||||||||||||| |Contact arrangement||||||||1 CO (SPDT) (ChangeOver -Simple Pole Double Throw-)|1 CO (SPDT) (ChangeOver -Simple Pole Double Throw-)|||||| |Maximum switching voltage||Maximum switching voltage||||||250 VAC/ 16 A resistive / 250 VDC / 0.3 A resistive|||250 VAC/ 16 A resistive / 250 VDC / 0.3 A resistive|250 VAC/ 16 A resistive / 250 VDC / 0.3 A resistive||| |Switching current rate (resistive)||||||||NO / NC: 16 A 250 V AC / 16 A 30 VDC @ 25°C|||NO / NC: 16 A 250 V AC / 16 A 30 VDC @ 25°C||NO / NC: 16 A 250 V AC / 16 A 30 VDC @ 25°C|| |||||||||NO / NC: 8 A 250 V AC / 8 A 30 VDC @ 60°C|||NO / NC: 8 A 250 V AC / 8 A 30 VDC @ 60°C|||| |Minimum switching contact||Minimum switching contact||||||10 mA / 5 VDC||||||| |Maximum switching power (resistive)||Maximum switching power (resistive)||||||4000 VA / 90 W @ 25°C||||||| |Electrical life||||||||30x103cycles (NO) at 250 VAC/ 16 A resistive|||cycles (NO) at 250 VAC/ 16 A resistive|||| |Maximum rate (at max switching power)||||||||360 cycles /hour||||||| |Mechanical life||||||||30 x 106cycles||||||| |Rated impulse voltage||||||||5 kV (1.2/50µs)|5 kV (1.2/50µs)|||||| |Dielectric strength between coil / contacts||||||||IEC 60664-1: 5 kV /1 min / 1 mA / 50 Hz||||||| |Dielectric strength between open contacts||||||||1 kV /1 min / 1 mA / 50 Hz|1 kV /1 min / 1 mA / 50 Hz|||||| |||||||||||||||| |Timing||||||||||||||| |Timing ranges (7 ranges)||||||||0.5→10s, 0.05→1min, 0.5→10min, 0.05→1h,||||||| |||||||||0.5→10h, 0.05→1day, 0.5→10days||||||| |Minimum pulse duration typically (relay version)||||||||IEC 1812-1: 30 ms / 100 ms with load||||||| |Maximum reset time by de-energisation typically (relay version)||||||||IEC 1812-1: 120 ms||||||| |Repeatability||||||||IEC 1812-1: ≤ ± 0,5 %||||||| |Repetition accuracy with constant parameters||Repetition accuracy with constant parameters||||||IEC 1812-1: ≤ ± 10 %||||||| |Drift Temperature||||||||≤ ± 0.05 % / °C||||||| |Voltage-dependent drift||Voltage-dependent drift||||||≤ ± 0.2 % / V||||||| |||||||||||||||| |Supply||||||||||||||| |Multi-voltage power supply||||||||12→240 V∿/⎓||||||| |Operating range||||||||15 %, +10 %||||||| |Operating frequency (Hz)||||||||50 / 60 Hz ± 5 %||||||| |Galvanic isolation||||||||No||||||| |Max. absorbed power||||||||Approx. 3 VA (V∿) 1.5 W (V⎓)||||||| |Immunity from micro power cuts||||||||10 ms||||||| **I** Timers **I 02** **I** www.crouzet-control.com |General characteristics|General characteristics| |---|---| |Insulation voltage, IEC 60664-1|300 V| |Installation category (acc. to IEC/EN 60664-1)|Overvoltage category III ; pollution degree 2| |Impulse voltage CEI/EN 60664-1|4 kV (1,2 / 50 µs)| |Clearance / Creepage distances|IEC 60664-1: 3 mm / 3.2 mm| |Breakdown voltage|EN-61812-1: 2,5 kV / 1 min / 1 mA / 50 Hz| |Insulation resistance|NFC 93 050: > 500 MΩ / 250 V⎓ / 1min| |Status indication|Un: green LED blinks when count, continuous ON when supplied<br>R: yellow LED continuous ON when the relay is ON| |Casing|DIN 43880: 17,5 mm| |Fixing: Symmetrical DIN rail|EN 50022: 35 mm| |Mounting position|All positions| |Housing material|Enclosure plastic type UL94 - V0| |Protection (IEC/EN 60529)|Housing: IP40 / Terminal block: IP20| |Terminal capacity Single-wire without ferrule|IEC 60947-1<br>1 x 0.5 →3.3 mm² (AWG 20 →AWG 12)<br>2 x 0.5 →1.5 mm² (AWG 20 →AWG 16)| |Max. tightening torque (Nm)|IEC 60947-1<br>0,5 N.m / 4,4 lbf.in| |Operating temperature range (°C)|IEC 60068-2<br>-20 °C →+60 °C| |Storage temperature range (°C)|IEC 60068-2<br>-40 °C →+70 °C| |Relative humidity no condensation acc. to IEC/EN 60068-2-30|93 % without condensation| |Vibration resistance according to IEC/EN 60068-2-6|± 0.15 mm from 10 Hz →60 Hz 2g from 60 Hz →150 Hz| |Impact resistance|IEC 60068-2-27<br>15gn - 11ms ; 3 x 6 axis (output OFF)<br>5gn - 11ms ; 3 x 6 axis (Output ON)| |Drop to concrete floor|IEC 60068-2-32: igh: 0.75m| |Weight: casing 17,5 mm|70 g<br>80 g with packaging| |Directives|2014/30/EU: EMC<br>2014/35/EU: low voltage| |Certifications|CE - cULus Listed Industrial Control Equipment - CCC| |Conformity to standards|CEI 60664-1: Insulation coordination for equipment within<br>low-voltage systems<br>CEI 61812-1/ Specified time relays for industrial use<br>UL 60947-4-1/ Industrial Control Equipment (NRNT- Industrial<br>Control Switches)| |Conformity with environmental directives|2015/863/UE: RoHS<br>1907/2006: Reach<br>2012/19/UE: WEEE| |Electromagnetic compatibility IEC 61000-6-2, IEC 61000-6-3,<br>IEC 61000-6-4|Immunity for industrial environment<br>Emission residential environment<br>Emission industrial environment| |Electromagnetic compatibility - Immunity to electrostatic discharges<br>acc to IEC/EN 61000-4-2|Level III Air ± 8 KV / Contact ± 6 KV| |Immunity to radiated, radio-frequency, electromagnetic field acc.<br>IEC/EN 61000-4-3|Level III<br>10 V/m (80 M Hz to 1 G Hz) 80 % AM (1 k Hz)<br>3 V/m (1,4 →2 G Hz) 80 % AM (1K Hz)<br>1V/m (2 →2.7 G Hz) 80 % AM (1K Hz)| |Immunity to rapid transient bursts acc. to IEC/EN 61000-4-4|Level III direct ± 2 kV (power supply) / capacitive coupling clamp<br>± 1 KV (command input and outputs)| |Immunity to shock waves on power supply acc. to IEC/EN 61000-4-5|Level III<br>line-to-earth ± 2 kV / line-to-line ± 1kV| **I** Timers **I 03** **I** www.crouzet-control.com ## General characteristics |General characteristics|General characteristics| |---|---| |Immunity to radio frequency in common mode acc. to<br>IEC/EN 61000-4-6|Level III<br>10 Vrms (0,15 →80 M Hz) 80 % AM (1 k Hz)| |Immunity to voltage dips and breaks acc. to IEC/EN 61000-4-11|Industrial Class II:<br>0 % residual voltage during 1cycle a.c. power ports<br>70 % residual voltage during 25/30 cycles a.c. power ports<br>0 % residual voltage, 250/300 cycles a.c. power ports<br>Residential:<br>0 % residual voltage during 10 cycle a.c.power ports<br>40 % residual voltage during 10 cycles a.c. power ports<br>70 % residual voltage during 10 cycles a.c. power ports<br>0 % residual voltage, 250/300 cycles a.c. power ports| |Mains-borne and radiated emissions acc. to EN 55022 (CISPR22),<br>EN55011 (CISPR11)|EN 55022 / CISPR22 Class B (IT equipment)<br>EN 55011 / CISPR11 Class B, Group 1 (Medical equipment)| Dimensions ## Curves > Function A U Delay on energisation 1 relay R T > Function At U Timing on Energisation with memory Y1 R t1 t2 T = t1+t2 Connections 1 changeover relay output U 7 + A1 Y1 15 R ; A2 16 18 ~~=~~ op **I** Timers **I 04 I** www.crouzet-control.com
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →