B84143A0035R106
Power Line Filter, General Purpose, 520 VAC, 35 A, Three Phase, 1 Stage, Chassis Mount
- Manufacturer: TDK
- Product type:
- SVHC: Lead (25-Jun-2025)
- No. of Phases: Three Phase
- No. of Stages: 1 Stage
- Product Range: B84143A Series
- Current Rating: 35A
- Voltage Rating: 520VAC
- Filter Mounting: Chassis Mount
- Filter Applications: General Purpose
- Filter Input Terminals: Terminal Block
- Filter Output Terminals: Terminal Block
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 107.3 € |
| Current stock | 10+ |
| Lead time | 30 days |
**EMC filters** 3-line filters for converters and power electronics **Series/Type: B84143A*R106** Date: December 2025 TDK Electronics AG 2025. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without TDK Electronics’ prior express consent is prohibited. ———E;_—xK—E”—>—E—ki—Ex—e **3-line filters B84143A*R106 for converters and power electronics** **Power line filters for 3-phase systems Rated voltage VR: 300/520 V AC Rated current IR: 10 A to 100 A** ## **Construction** - 3-line filters - Metal case ## **Features** **Features** High insertion loss Schematic picture Optimized leakage current Easy to install Low weight Compact design Degree of protection: IP 20[1)] Optimized for long motor cables and operation under full load ENEC, UL and cUL approval & AW cA **Typical applications** Frequency converters for motor drives, e.g. – elevators – pumps – conveyor systems – HVAC systems (heating, ventilation and air conditioning) Power supplies Textile machines, packaging machines, machine-tools **Terminals** Finger-safe terminals **Marking** Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code, approvals Minimum data on packaging: Manufacturer's logo, ordering code, quantity, date code 1) According to IEC 60529 Please read _Cautions and warnings_ and _Important notes_ at the end of this document. **2** 12/25 **2** a **3-line filters** **B84143A*R106** **for converters and power electronics** ## **Typical circuit diagram** |**Technical data and measuring conditions**<br>w Designs|**Technical data and measuring conditions**<br>w Designs|**Technical data and measuring conditions**<br>w Designs|**Technical data and measuring conditions**<br>w Designs|**Technical data and measuring conditions**<br>w Designs|**Technical data and measuring conditions**<br>w Designs|**Technical data and measuring conditions**<br>w Designs|**Technical data and measuring conditions**<br>w Designs|**Technical data and measuring conditions**<br>w Designs| |---|---|---|---|---|---|---|---|---| |Rated voltage VR<br>|||300/520 V AC (50/60 Hz)<br>e|||||| |Rated voltage for IT mains supply<br>|||265/460 V AC (50/60 Hz)<br>See also chapter “Technical information”, section 8 “Energy supply<br>networks”.<br>r N|||||| |Rated current IR<br>|||Referred to 50 °C rated temperature<br>fo|||||| |Test voltage Vtest<br>|||2240 V DC, 2 s (line/line)<br>2720 V DC, 2 s (lines/case)<br>ed|||||| |Overload capability (thermal)<br>|||1.5 · IRfor 3 min per hour or<br>2.5 · IRfor 30 s per hour<br>nd|||||| |Leakage current lLK<br>|||At VRand 50 Hz<br>e|||||| |Climatic category (IEC 60068-1)<br>|||25/100/21 (–25 °C/+100 °C/21 days damp heat test)<br>|||||| |Approvals<br>|||IEC 60939, UL 1283, CSA C22.2 No.8<br>|||||| |**Characteristics and ordering codes**<br>co||||||||| |IR<br>A|Terminal<br>cross section<br>mm2<br>ot R|ILK<br>mA<br>|Rtyp<br>mΩ<br>|Approx.<br>weight<br>kg<br>|Ordering code<br>|Approvals<br>||| |VR= 300/520 V AC<br>N||||||||| |10<br>20<br>35<br>50<br>65<br>80<br>100|4<br>4<br>10<br>25<br>25<br>50<br>50<br>|3.1<br>3.1<br>3.4<br>3.4<br>3.4<br>3.4<br>3.4<br>|5.5<br>3.3<br>1.7<br>1.1<br>0.94<br>0.60<br>0.48<br>|0.4<br>0.5<br>0.8<br>1.3<br>1.4<br>2.1<br>2.5<br>|B84143A0010R106<br>B84143A0020R106<br>B84143A0035R106<br>B84143A0050R106<br>B84143A0065R106<br>B84143A0080R106<br>B84143A0100R106<br>|×<br>×<br>×<br>×<br>×<br>×<br>×<br>|×<br>×<br>×<br>×<br>×<br>×<br>×<br>|×<br>×<br>×<br>×<br>×<br>×<br>×<br>| × = Approval granted Please read _Cautions and warnings_ and _Important notes_ at the end of this document. 12/25 **3** **B84143A*R106** ## **3-line filters** **for converters and power electronics** ## **Dimensional drawings** **B84143A0010R106, B84143A0020R106 (10 A, 20 A)** **==> picture [517 x 585] intentionally omitted <==** **----- Start of picture text -----**<br> General tolerances according to ISO 2768–cL<br>Dimensions in mm<br>B84143A0035R106 (35 A)<br>General tolerances according to ISO 2768–cL<br>Dimensions in mm<br>Not Recommended for New Designs<br>**----- End of picture text -----**<br> Please read _Cautions and warnings_ and _Important notes_ at the end of this document. **4** 12/25 **B84143A*R106** ## **3-line filters** **for converters and power electronics** ## **B84143A0050R106, B84143A0065R106 (50 A, 65 A)** General tolerances according to ISO 2768–cL Dimensions in mm **B84143A0080R106 (80 A)** General tolerances according to ISO 2768–cL Dimensions in mm Please read _Cautions and warnings_ and _Important notes_ at the end of this document. 12/25 **5** **3-line filters** **B84143A*R106** **for converters and power electronics** ## **B84143A0100R106 (100 A)** General tolerances according to ISO 2768–cL Dimensions in mm Please read _Cautions and warnings_ and _Important notes_ at the end of this document. 12/25 **6** ~~ee~~ **3-line filters B84143A*R106 for converters and power electronics** **==> picture [477 x 559] intentionally omitted <==** **----- Start of picture text -----**<br> Insertion loss (typical values at Z = 50 Ω)<br>unsymmetrical, adjacent branches terminated<br>common mode, all branches in parallel (asymmetrical)<br>differential mode (symmetrical)<br>Filters for 10 A Filters for 20 A<br>100 SSB2332-C 100 SSB2333-K<br>ae | | ||| ||]|[[Be4t4saqor0R105 | a6 |_| ||| ||]|f\2e4t4sAoczoR05 |<br>ee TF<br>80 'N [tN I LI<br>Ie 80 f<br>Se ST<br>« Oy Ss ull « SHUT A Tl<br>ol AUAEH I VESSNEWa ol NNTEIT LLMISNUl<br>LAT PA SE UT Ne<br>vot ANE TIEIEN ar Al Mae<br>7 AA h A ai X<br>ELI 1 04 10° LUMI 10° UII 10’ LA Hz 108 o104 C [LLUILLME] 10° 10° LIL 10’ LA Hz 108<br>—— » f —— » f<br>Filters for 35 A Filters for 50 A<br>100 SSB2334-T 100 SSB2335-2<br>ap Be4tesao095r706 | ||| | ||| ap Be4tesa0050R"06| ||| |||<br>uO a a so HAN LATE LT UU<br>A Ih "<br>CUTE ge LAT LL ST Tt<br>mT siSE oo ETT<br>« SRTSEN y in « SUCURE y THITIURNAI os UlTTil<br>a | | INV<br>Not Recommended for New Designs<br>**----- End of picture text -----**<br> Please read _Cautions and warnings_ and _Important notes_ at the end of this document. 12/25 **7** ~~ee~~ **3-line filters B84143A*R106 for converters and power electronics** ## **Insertion loss (typical values at Z = 50 Ω)** **==> picture [477 x 706] intentionally omitted <==** **----- Start of picture text -----**<br> unsymmetrical, adjacent branches terminated<br>common mode, all branches in parallel (asymmetrical)<br>differential mode (symmetrical)<br>Filters for 65 A Filters for 80 A<br>100 SSB2336-A 100 SSB2337-1<br>A ap Beer4aaooesRI06 ||| | ap Beer4aaoosoRt0s||) ||<br>80 Ny A 80 iy ALU<br>ST CE<br>THES “ E<br>0 A Sa AT Se<br>SOE TSN VENT TI Nal<br>il aN0<br>X04 10° 106 10’ Hz 108 X04 10° 106 10’ Hz 108<br>—— » f —— » f<br>Filters for 100 A<br>100 SSB2338-R<br>ap Be4r4sAoto0R 06 |||) |<br>A<br>CE<br>« Se. a<br>CP a nT<br>7 OSS<br>TAR HIS N Sea<br>Pa cillQMO<br>AA<br>X04 10° 106 10’ Hz 108<br>—___ » f<br>Please read Cautions and warnings and<br>Important notes at the end of this document. 8 12/25<br>Not Recommended for New Designs<br>**----- End of picture text -----**<br> **3-line filters** **B84143A*R106** **for converters and power electronics** ## **Cautions and warnings** - Please note further advice in our website www.tdk-electronics.tdk.com/pemc_filters_gti - It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. - Danger of electric shock: The products contain components that store an electric charge. Dangerous voltages can continue to exist at the product terminals for longer than five minutes even after the power has been switched off. - The protective earth connections shall be the first to be made when the product is installed and secured against loosening by defined tightening torque. Remove them at last, when uninstalling. Depending on the magnitude of the leakage currents, the particular specifications for making the protective−earth connection must be observed. - Impermissible overloading of the product, such as with circuits able to cause resonances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as cause substantial material damages (e.g. destruction of the product housing). - The products must be protected in the application against impermissible exceeding of the rated currents by overcurrent protective devices. - For leakage currents >10 mA, a fixed connection of the protective earth conductor to the public power grid is required. This means that connection via plug connectors is not permitted. The protective conductor must have a minimum cross-section of 10 mm[2] Cu or 16 mm[2] Al over its entire length. Alternatively, two separate protective conductors with the minimum cross-section specified in each case can also be connected. - For leakage currents 3.5 mA < ILK[a)] ≤ 10 mA, the following solutions are possible: – Stationary device with fixed connection - – Stationary device with type B plug-in connection (industrial plug-in connection according to IEC 60309) and cross-section ≥ 2.5 mm[2] - – Stationary device with type A plug-in connection (non-industrial plug-in device) and additional second protective earth connection - – Movable equipment with type A plug-in connection and additional second protective earth connection in premises with restricted access - The products must be protected in the application against impermissible exceeding of the specification parameter. - The converter output frequency must be within the specified range to avoid resonances and uncontrolled warming of the output chokes and output filters. - The components can become very hot during operation, there is the risk of burns if touched. The product can remain hot for some time after the power is switched off! - The products are only to be attached to the fixings or mounting holes provided for this purpose in accordance with the data sheet. It is not permitted for the product specified in the data sheet to assume a mechanical function in the final application, in particular any type of tension or pressure on the product must be prevented. - With surface-treated sheets (e.g. galvanized), edge rust may occur due to the manufacturing process. This does not constitute a quality defect. Alternative materials are available if required. - Movable equipment with type A plug-in connection and additional second protective earth connection in premises with restricted access - The products must be protected in the application against impermissible exceeding of the specification parameter. a) ILK = Leakage current **9** 12/25 **3-line filters** **B84143A*R106** **for converters and power electronics** ## **Display of ordering codes for TDK Electronics products** The ordering code for one and the same product can be represented differently in data sheets, data books, other publications, on the company website, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.tdk-electronics.tdk.com/orderingcodes. 12/25 **10** **3-line filters** **B84143A*R106** **for converters and power electronics** ## **Symbols and terms** |Symbol|English|German| |---|---|---| |<br>CR<br>CX<br>CY<br>V<br>dv/dt<br>f<br>fM<br>fP<br>fR<br>fres<br>IC<br>ILK<br>Imax<br>IN<br>Iop<br>Ipk<br>Iq<br>IR<br>IS<br>L<br>LR<br>Lstray<br>PL<br>R<br>Ris<br>Rtyp<br>TA<br>Tmax<br>|Insertion loss<br>Rated capacitance<br>Capacitance X capacitor<br>Capacitance Y capacitor<br>Voltage drop (input to output)<br>Rate of voltage rise<br>Frequency<br>Converter output frequency<br>Pulse frequency<br>Rated frequency<br>Resonant frequency<br>Current through capacitor<br>Filter leakage current<br>Maximum current<br>Nominal current<br>Operating current (design current)<br>Rated peak withstand current<br>Capacitive reactive current<br>Rated current<br>Interference current<br>Inductance<br>Rated inductance<br>Stray inductance<br>Power loss<br>Resistance<br>Insulation resistance<br>DC resistance, typical value<br>Ambient temperature<br>Upper category temperature<br>Not Recommende|Einfügungsdämpfung<br>Bemessungskapazität<br>Kapazität X-Kondensator<br>Kapazität Y-Kondensator<br>Spannungsabfall (Eingang zu Ausgang)<br>Spannungsanstiegsgeschwindigkeit<br>Frequenz<br>Motorfrequenz<br>Pulsfrequenz<br>Bemessungsfrequenz<br>Resonanzfrequenz<br>Strom durch Kondensator<br>Filter-Ableitstrom<br>Maximalstrom<br>Nennstrom<br>Betriebsstrom<br>Bemessungsstoßstromfestigkeit<br>Kapazitiver Blindstrom<br>Bemessungsstrom<br>Störstrom<br>Induktivität<br>Bemessungsinduktivität<br>Streuinduktivität<br>Verlustleistung<br>Widerstand<br>Isolationswiderstand<br>Gleichstromwiderstand typisch<br>Umgebungstemperatur<br>Obere Kategorietemperatur<br>d for New Designs| Please read _Cautions and warnings_ and _Important notes_ at the end of this document. **11** 12/25 **3-line filters** **B84143A*R106** **for converters and power electronics** Symbol English German Tmin Lower category temperature Untere Kategorietemperatur TR Rated temperature Bemessungstemperatur vk Referred voltage drop in % Bezogener Spannungsabfall in % Veff RMS voltage Effektivspannung VK Voltage drop Spannungsabfall VLE Voltage line to earth; voltage line to ground Spannung Phase zu Erdpotential VN Nominal voltage Nennspannung VR Rated voltage Bemessungsspannung Vpeak Peak voltage Spitzenspannung Vtest Test voltage Prüfspannung VX Voltage over X capacitor Spannung über X-Kondensator VY Voltage over Y capacitor Spannung über Y-Kondensator XL Inductive reactance Induktiver Blindwiderstand Z Impedance Scheinwiderstand |Z| Impedance, absolute value Scheinwiderstand (Betragswert) Please read _Cautions and warnings_ and _Important notes_ at the end of this document. 12/25 **12** ## **Important notes** The following applies to all products named in this publication: - 1 Some parts of this publication contain **statements about the suitability of our products for certain areas of application** . These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out **that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application** . As a rule we are either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether a product with the properties described in the product specification is suitable for use in a particular customer application. - 2 We also point out that **in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified** . In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. - 3 **The warnings, cautions and product-specific notes must be observed** . 4 In order to satisfy certain technical requirements, **some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous)** . Useful information on this will be found in our Material Data Sheets on the Internet (www.tdk-electronics.tdk.com/material). Should you have any more detailed questions, please contact our sales offices. - 5 We constantly strive to improve our products. Consequently, **the products described in this publication may change from time to time** . The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also **reserve the right to discontinue production and delivery of products** . Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. - 6 Unless otherwise agreed in individual contracts, **all orders are subject to our General Terms and Conditions of Supply** . - 7 **Our manufacturing sites serving the automotive business apply the IATF 16949 standard** . The IATF certifications confirm our compliance with requirements regarding the quality management system in the automotive industry. Referring to customer requirements and customer specific requirements (“CSR”) TDK always has and will continue to have the policy of respecting individual agreements. Even if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to emphasize that **only requirements mutually agreed upon can and will be implemented in our Quality Management System** . For clarification purposes we like to point out that obligations from IATF 16949 shall only become legally binding if individually agreed upon. **13** 12/25 ## **Important notes** - 8 The trade names EPCOS, CarXield, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS, DeltaCap, DigiSiMic, FilterCap, FormFit, InsuGate, LeaXield, MediPlas, MiniBlue, MiniCell, MKD, MKK, ModCap, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PiezoBrush, PlasmaBrush, PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SurfIND, ThermoFuse, WindCap, XieldCap are **trademarks registered or pending** in Europe and in other countries. Further information will be found on the Internet at www.tdkelectronics.tdk.com/trademarks. ## Release 2024-02 12/25 **14**
Updated at June 10, 2026
TDK Corporation is a globally recognized leader in electronic components and magnetic materials. Founded in 1935 to commercialize ferrites, the Tokyo-based company has evolved into a comprehensive manufacturer of high-performance passive components, sensors, and power electronics. TDK’s advanced materials technology serves as the foundation for its extensive portfolio, driving innovation across automotive, industrial, consumer electronics, and communication technologies. Our selection of TDK components heavily features their industry-leading passive components, with a primary focus on magnetics. TDK excels in manufacturing reliable inductive solutions, offering a vast array of power inductors and RF inductors optimized for demanding power management and high-frequency applications. Furthermore, their expertise in electromagnetic compatibility is showcased through a comprehensive range of EMC and RFI suppression products. This includes common mode chokes, power line filters, and specialized shielding materials designed to ensure superior signal integrity in complex designs. Beyond inductors and filtering components, TDK provides robust circuit protection and sensing solutions essential for modern engineering. The portfolio includes precision temperature sensing and compensation NTC thermistors, alongside TVS varistors and inrush current limiting components that safeguard sensitive electronics. Complemented by fixed value inductors, supercapacitors, and charging coils, TDK's versatile product offering delivers the reliability and performance required for sophisticated circuit design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →