Image not available
Illustrative purposes only
B3.1/5-PKZ0
Busbar Link, 3 Phase, PKZ0, PKE12 & PKE32 Series Circuit Breakers
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON MOELLER
- Product type: Circuit Breaker Accessories
- SVHC: No SVHC (17-Dec-2015)
- Product Range: B3 Series
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 19.64 € |
| Current stock | 10+ |
| Lead time | 30 days |
**DATASHEET - B3.1/5-PKZ0** **Three-phase commoning link, Circuit-breaker: 5, 261 mm, For PKZM0-... or PKE12, PKE32 without side mounted auxiliary contacts or voltage releases** **Part no. B3.1/5-PKZ0 Catalog No. 044948 Alternate Catalog XTPAXCLKB5 No. EL-Nummer 4357232 (Norway)** ## **Delivery program** |**No.**<br>**EL-Nummer**<br>**(Norway)y)) **<br>**4357232**<br>**Deliveryy programrogramgramram**|||| |---|---|---|---| |Product range|||Accessories| |Accessories|||Three-phase commoning link| ||||Protected against accidental contact, short-circuit proof, Ue= 690 V, Iu= 63 A<br>Can be extended by rotating by installation<br>For PKZM0-... or PKE attached on the right with an auxiliary contact or trip<br>indicating signal| |For use with|||Three-phase commoning link PKZ0, PKE12, PKE32| |Circuit-breaker||Number|5| |Length||mm|261| |Unit width||mm|45 + 9| |**Notes**<br>For parallel power feed to several motor-protective circuit-breakers on terminals 1, 3, 5|||| ## **Notes** For parallel power feed to several motor-protective circuit-breakers on terminals 1, 3, 5 ## **Technical data** |**Technical data**|**Technical data**|||| |---|---|---|---|---| |**Main conducting paths**||||| ||Rated impulse withstand voltage|Uimp|V AC|6000| ||Overvoltage category/pollution degree|||III/3| ||Rated operational voltage|Ue|V AC|690| ||Rated uninterrupted current|Iu|A|63| ## **Desig per IEC/EN 61439** |**Desiggn verification asper IEC/EN 61439er IEC/EN 61439**|||| |---|---|---|---| |**n verification as**<br>Technical data for design verification|||| |Technical data for design verification<br>Rated operational current for specified heat dissipation|In|A|63| |Heat dissipation per pole, current-dependent|Pvid|W|2.8| |Equipment heat dissipation, current-dependent|Pvid|W|8.4| |Static heat dissipation, non-current-dependent|Pvs|W|0| |Heat dissipation capacity|Pdiss|W|0| |Operating ambient temperature min.||°C|-25| |Operating ambient temperature max.||°C|55| |IEC/EN 61439 design verification|||| |IEC/EN 61439 design verification<br>10.2 Strength of materials and parts|||| |10.2.2 Corrosion resistance|||Meets the product standard's requirements.| |10.2.3.1 Verification of thermal stability of enclosures|||Meets the product standard's requirements.| |10.2.3.1 Verification of thermal stability of enclosures<br>10.2.3.2 Verification of resistance of insulating materials to normal heat|||Meets the product standard's requirements.| |10.2.3.2 Verification of resistance of insulating materials to normal heat<br>10.2.3.3 Verification of resistance of insulating materials to abnormal heat<br>and fire due to internal electric effects|||Meets the product standard's requirements.| |and fire due to internal electric effects<br>10.2.4 Resistance to ultra-violet (UV) radiation|||Meets the product standard's requirements.| |10.2.5 Lifting|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.6 Mechanical impact|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.7 Inscriptions|||Meets the product standard's requirements.| |10.3 Degree of protection of ASSEMBLIES|||Does not apply, since the entire switchgear needs to be evaluated.| |10.4 Clearances and creepage distances|||Meets the product standard's requirements.| |10.5 Protection against electric shock|||Does not apply, since the entire switchgear needs to be evaluated.| |10.6 Incorporation of switching devices and components|||Does not apply, since the entire switchgear needs to be evaluated.| |10.7 Internal electrical circuits and connections|||Is the panel builder's responsibility.| 07/12/2020 Eaton 044948 ED2020 V70.0 EN 1 / 3 |10.8 Connections for external conductors|||Is the panel builder's responsibility.| |---|---|---|---| |10.9 Insulation properties|||| |10.9.2 Power-frequency electric strength|||Is the panel builder's responsibility.| |10.9.3 Impulse withstand voltage|||Is the panel builder's responsibility.| |10.9.4 Testing of enclosures made of insulating material|||Is the panel builder's responsibility.| |10.10 Temperature rise|||The panel builder is responsible for the temperature rise calculation. Eaton will<br>provide heat dissipation data for the devices.| |10.11 Short-circuit rating|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |10.12 Electromagnetic compatibility|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |10.13 Mechanical function|||The device meets the requirements, provided the information in the instruction<br>leafet (IL) is observed.| ## **Technical data ETIM 7.0** Low-voltage industrial components (EG000017) / Phase busbar (EC000215) Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Phase busbar (ecl@ss10.0.1-27-37-13-06 [ACN992011]) |**Technical data ETIM 7.0**|**Technical data ETIM 7.0**|**Technical data ETIM 7.0**|**Technical data ETIM 7.0**| |---|---|---|---| |Low-voltage industrial components (EG000017) / Phase busbar (EC000215)|||| |Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Phase busbar (ecl@ss10.0.1-27-37-13-06<br>[ACN992011])|||| |Number of phases|||3| |Number of poles|||3| |Suitable for number of devices|||5| |Pitch dimensions||mm|54| |Cross section||mm²|0| |Length||mm|261| |Number of modular spacings|||0| |Rated permanent current Iu||A|63| |Type of electric connection|||Fork| |Insulated|||Yes| |Rated surge voltage||kV|6| |Conditioned rated short-circuit current Iq||kA|0| |Max. rated operation voltage Ue||V|690| |Rated short-time withstand current lcw||kA|0| |Suitable for devices with N-busbar|||No| |Suitable for devices with auxiliary switch|||No| ## **Approvals** |**Approvals**|||| |---|---|---|---| |Product Standards|||UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking| |UL File No.|||E36332| |UL Category Control No.|||NLRV| |CSA File No.|||98494| |CSA Class No.|||3211-06| |North America Certifcation|||UL listed, CSA certifed| |<br>Specially designed for North America|||<br>No| 07/12/2020 Eaton 044948 ED2020 V70.0 EN 2 / 3 **Dimensions** Three-phase commoning link ## **Additional product information (links)** Motor starters and "Special Purpose Ratings" for the North American market Busbar Component Adapters for modern Industrial control panels http://www.eaton.eu/ecm/groups/public/@pub/@europe/@electrical/documents/content/pct_3258146.pdf http://www.moeller.net/binary/ver_techpapers/ver960en.pdf Eaton Industries GmbH http://www.eaton.eu © 07/2020 by Eaton Industries GmbH Eaton 044948 ED2020 V70.0 EN 07/12/2020 3 / 3
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →