B-TL70B-Q5
SIGNAL INDICATOR ACCESSORIES
- Manufacturer: BANNER ENGINEERING
- Product type: Signal Indicator Accessories
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 48.43 € |
| Current stock | 10+ |
| Lead time | 30 days |
## TL70B Modular Tower Light Product Manual Original Instructions p/n: 233350 Rev. E 27-Jan-26 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com TL70B Modular Tower Light Product Manual ## Contents **Chapter 1 Features.................................................................................................................. 3** Models ........................................................................................................................................................................................................... 3 **Chapter 2 Assembling the Modules ...................................................................................... 5 Chapter 3 Wiring...................................................................................................................... 6** Flash/Pulse Control ....................................................................................................................................................................................... 6 **Chapter 4 Specifications ........................................................................................................ 7** FCC Part 15 Class B for Unintentional Radiators.......................................................................................................................................... 8 Industry Canada ICES-003(B)....................................................................................................................................................................... 8 Dimensions.................................................................................................................................................................................................... 8 **Chapter 5 Accessories.......................................................................................................... 10** Cordsets ...................................................................................................................................................................................................... 10 Mounting Brackets........................................................................................................................................................................................11 Elevated Mount System............................................................................................................................................................................... 13 LMB Sealed Right Angle Bracket ............................................................................................................................................................... 14 Top Replacement Cover.............................................................................................................................................................................. 15 **Chapter 6 Product Support and Maintenance .................................................................... 16** Clean with Mild Detergent and Warm Water ............................................................................................................................................... 16 Repairs ........................................................................................................................................................................................................ 16 Contact Us................................................................................................................................................................................................... 16 Banner Engineering Corp Limited Warranty................................................................................................................................................ 16 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com TL70B Modular Tower Light Product Manual ## Chapter Contents Models.................................................................................................................................................................................................................. 3 ## Chapter 1 ## Features Banner's TL70B Tower Light is a 70 mm, modular LED indicator with bright and uniform light. The modularity gives the user flexibility to customize tower lights as needed and change positions in the field. The TL70 is also available preassembled for easy installation. - Light segments have user-selectable solid ON or flashing - Up to five indicator segments, or four indicator segments plus audible, in one device - Rugged, water-resistant IP65 and IP66 housing with UV-stabilized material - Bright, uniform indicator segments appear gray when off to eliminate false indications from ambient light - Simple and fast connection with M12 quick-disconnect connector ## Models ## TL70B Base Model Key **==> picture [368 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> Housing — Connection<br>B-TL70B — Q8<br>Q5 = Integral 5-pin M12 male quick-disconnect connector<br>TL70B Base<br>Q8 = Integral 8-pin M12 male quick-disconnect connector<br>**----- End of picture text -----**<br> **==> picture [104 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> TL70B Segments Model Key<br>**----- End of picture text -----**<br> **==> picture [319 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> Housing — Color/Alarm<br>SG-TL70B — G<br>G = Green<br>Y = Yellow<br>R = Red<br>B = Blue<br>TL70B Segment<br>W = White<br>O = Orange<br>V = Violet<br>A = Standard Audible<br>**----- End of picture text -----**<br> Select the 5-pin base for tower light configurations of up to 4 modules. Select the 8-pin base for tower light configurations of up to 5 modules. - Example base model number: B-TL70B-Q5 - Example light segment model number: SG-TL70B-G - Example audible segment model number: SG-TL70B-A ## TL70B Pre-Assembled Models Part Number **==> picture [21 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Model<br>**----- End of picture text -----**<br> 814501 TL70B-GYRQ Continued on page 4 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 3 of 17 27-Jan-26 TL70B Modular Tower Light Product Manual Features **==> picture [500 x 83] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 3<br>Part Number Model<br>814502 TL70B-GYRAQ<br>814503 TL70B-BGYRQ<br>814504 TL70B-BGYRAQ<br>814505 TL70B-WBGYRQ<br>**----- End of picture text -----**<br> page 4 of 17 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 27-Jan-26 TL70B Modular Tower Light Product Manual ## Chapter Contents ## Chapter 2 ## Assembling the Modules **==> picture [135 x 185] intentionally omitted <==** **==> picture [134 x 167] intentionally omitted <==** ## IMPORTANT: - Do not assemble or swap segments while the unit is powered on. - Ensure power is off when assembling or swapping segments. ## To assemble the modules: 1. Align the notches on each module and press together. 2. Rotate the top module clockwise to lock into place (notches shown in the locked position). NOTE: DIP switches should remain in the default off position. © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 5 of 17 27-Jan-26 TL70B Modular Tower Light Product Manual ## Chapter Contents Flash/Pulse Control.............................................................................................................................................................................................. 6 ## Chapter 3 ## Wiring **==> picture [500 x 212] intentionally omitted <==** **----- Start of picture text -----**<br> Diagram 5-Pin Pinout 8-Pin Pinout<br>Position 5<br>2 1<br>2 1 3 7<br>Position 4<br>8 6<br>5<br>Position 3 4 5<br>3 4<br>1 = White (Position 3)<br>2 = Brown (Position 2)<br>Position 2 1 = Brown (Position 2) 3 = Green (Not used)<br>2 = White (Position 3)<br>4 = Yellow (Position 5)<br>3 = Blue (Ground)<br>5 = Gray (Position 4)<br>Position 1 4 = Black (Position 1) 6 = Pink (Position 1)<br>5 = Gray (Position 4)<br>7 = Blue (Ground)<br>8 = Red (Not used)<br>**----- End of picture text -----**<br> ## Flash/Pulse Control The DIP switch is located in the TL70B base segment. DIP switch numbers 1-5 correlate to Positions 1-5 (see diagram above). DIP switch number 7 sets a global speed for the flashing function. DIP switch numbers 6 and 8 are not used. **==> picture [500 x 84] intentionally omitted <==** **----- Start of picture text -----**<br> DIP Switch Light Segment Audible Segment<br>Diagram Function<br>Number<br>On Off On Off<br>Toggle Flash ON/<br>1-5 Flash Steady Pulse Continuous<br>OFF<br>1 2 3 4 5 6 7 8 7 Toggle Flash Speed 1.5 Hz 3 Hz 1.5 Hz 3 Hz<br>**----- End of picture text -----**<br> Adjustable audible baffle - for audible models only **==> picture [125 x 125] intentionally omitted <==** **==> picture [86 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> Adjustable Baffle<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 6 of 17 27-Jan-26 TL70B Modular Tower Light Product Manual ## Chapter Contents FCC Part 15 Class B for Unintentional Radiators ................................................................................................................................................ 8 Industry Canada ICES-003(B).............................................................................................................................................................................. 8 Dimensions........................................................................................................................................................................................................... 8 ## Chapter 4 ## Specifications Supply Voltage and Current 12 V DC to 30 V DC **==> picture [210 x 83] intentionally omitted <==** **----- Start of picture text -----**<br> Maximum Current (mA)<br>Indicator Color or Audible Model<br>at 24 V at 30 V<br>at 12 V DC<br>DC DC<br>Blue, White 204 102 82<br>Red, Orange, Yellow, Green, 141 71 57<br>Violet<br>Standard Audible 33 17 14<br>**----- End of picture text -----**<br> ## Supply Protection Circuitry Protected against transient voltages ## Indicators 1 to 5 colors depending on model (Green, Red, Yellow, Blue, White, Orange, and Violet) ## Indicator Characteristics **==> picture [213 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> Color Lumen<br>Dominant Wavelength<br>Coordinates [(1)] Output<br>Color (nm) or Color<br>(Typical at<br>Temperature (CCT) x y 25 °C)<br>Green 525 nm – – 67<br>Red 625 nm – – 24<br>Yellow 590 nm – – 55<br>Blue 475 nm – – 25<br>White 5000 K – – 107<br>Orange 605 nm – – 29<br>Violet – 0.214 0.133 28<br>**----- End of picture text -----**<br> ## Required Overcurrent Protection Flash Rates: 1.5 Hz ±10% and 3 Hz ±10% ## Indicator Response Time - Off Response: 25 µs (maximum) at 12 V DC to 30 V DC On Response: 2 ms (maximum) at 12 V DC to 30 V DC ## Connections Integral 5-pin M12 male quick-disconnect connector, integral 8-pin M12 male quick-disconnect connector ## Operating Conditions –40 °C to +50 °C (–40 °F to +122 °F) 95% at +50 °C maximum relative humidity (non-condensing) Environmental Rating IP65, IP66 WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. ## Audible Alarm - 2.7 kHz ± 250 Hz oscillation frequency; maximum intensity (typical) 104 dB at 1 m (3.3 ft) ## Audible Adjustment Rotate the audible baffle until the desired volume is reached Typical Reduction in Sound Intensity with Audible Adjustment (maximum to minimum): 13 dB ## Construction **==> picture [208 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> Supply Supply<br>Required Overcurrent Required Overcurrent<br>Wiring Wiring<br>Protection (A) Protection (A)<br>(AWG) (AWG)<br>20 5.0 26 1.0<br>22 3.0 28 0.8<br>24 2.0 30 0.5<br>**----- End of picture text -----**<br> Bases, Segments, Covers: polycarbonate ## Vibration and Mechanical Shock Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC 60068-2-6 Shock: 15G 11 ms duration, half sine wave per IEC 60068-2-27 Certifications **==> picture [100 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> Banner Engineering BV<br>Park Lane, Culliganlaan 2F bus 3<br>1831 Diegem, BELGIUM<br>**----- End of picture text -----**<br> **==> picture [101 x 29] intentionally omitted <==** **----- Start of picture text -----**<br> Turck Banner LTD Blenheim House<br>Blenheim Court<br>Wickford, Essex SS11 8YT<br>GREAT BRITAIN<br>**----- End of picture text -----**<br> (1) Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 7 of 17 27-Jan-26 Specifications TL70B Modular Tower Light Product Manual ## FCC Part 15 Class B for Unintentional Radiators (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. (Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. ## Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. **==> picture [500 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> M30 × 1.5<br>(mounting nut 24.9 mm<br>included)<br>[0.98”]<br>Internal threads<br>1/2-14 NPT<br>Max Torque: 2.25 Nm<br>[20 in-lbf] M12 × 1<br>Model Height (H)<br>1 light module 87.6 mm (3.45 in)<br>Continued on page 9<br>**----- End of picture text -----**<br> page 8 of 17 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 27-Jan-26 Specifications TL70B Modular Tower Light Product Manual **==> picture [500 x 164] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 8<br>Model Height (H)<br>1 light module, 1 audible module 144.3 mm (5.68 in)<br>2 light modules 137.3 mm (5.41 in)<br>2 light modules, 1 audible module 194 mm (7.64 in)<br>3 light modules 187 mm (7.36 in)<br>3 light modules, 1 audible module 243.7 mm (9.59 in)<br>4 light modules 236.7 mm (9.32 in)<br>4 light modules, 1 audible module 293.4 mm (11.55 in)<br>5 light modules 286.4 mm (11.28 in)<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 9 of 17 27-Jan-26 TL70B Modular Tower Light Product Manual ## Chapter Contents |Cordsets ............................................................................................................................................................................................................. 10| |---| |Mounting Brackets...............................................................................................................................................................................................11| |Elevated Mount System ..................................................................................................................................................................................... 13| |LMB Sealed Right Angle Bracket ...................................................................................................................................................................... 14| |Top Replacement Cover..................................................................................................................................................................................... 15| |Accessories<br>Chapter 5| ## Cordsets **==> picture [500 x 414] intentionally omitted <==** **----- Start of picture text -----**<br> 5-Pin Single-Ended M12 Female Cordsets<br>Model Length Style Dimensions Pinout (Female)<br>MQDC1-501.5 0.5 m (1.5 ft)<br>MQDC1-503 0.9 m (2.9 ft)<br>44 Typ.<br>MQDC1-506 2 m (6.5 ft)<br>MQDC1-515 5 m (16.4 ft) Straight 1 2<br>MQDC1-530 9 m (29.5 ft) M12 x 1 5<br>ø 14.5<br>MQDC1-560 18 m (59 ft) 4 3<br>MQDC1-5100 31 m (101.7 ft) 1 = Brown<br>2 = White<br>MQDC1-506RA 2 m (6.5 ft) 32 Typ. 3 = Blue<br>[1.26"] 4 = Black<br>MQDC1-515RA 5 m (16.4 ft) 5 = Gray<br>MQDC1-530RA 9 m (29.5 ft) 30 Typ.<br>Right-Angle [1.18"]<br>MQDC1-560RA 19 m (62.3 ft)<br>M12 x 1<br>ø 14.5 [0.57"]<br>5-Pin Double-Ended M12 Female to M12 Male Cordsets<br>Model Length Style Dimensions Pinout (Male) Pinout (Female)<br>2 1 1 2<br>MQDEC-501SS 0.31 m (1.02 ft) 40 Typ. 5 5<br>3 4 4 3<br>MQDEC-503SS 0.91 m (2.99 ft) M12 x 1<br>Male Straight/Female ø 14.5<br>MQDEC-506SS 1.83 m (6 ft) Straight 44 Typ.<br>MQDEC-512SS 3.66 m (12 ft) 1 = Brown 4 = Black<br>2 = White<br>MQDEC-515SS 5 m (16.4 ft) M12 x 1 3 = Blue 5 = Gray<br>ø 14.5<br>MQDEC-530SS 9 m (29.5 ft)<br>MQDEC-550SS 15 m (49.2 ft)<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 10 of 17 27-Jan-26 TL70B Modular Tower Light Product Manual Accessories **==> picture [500 x 411] intentionally omitted <==** **----- Start of picture text -----**<br> 8-Pin Single-Ended M12 Female Cordsets<br>Model Length Style Dimension Pinout (Female)<br>MQDC1-803 1 m (3.2 ft)<br>44 Typ. 1 2<br>MQDC1-806 2 m (6.5 ft)<br>7 3<br>MQDC1-815 5 m (16.4 ft) Straight<br>8 4<br>MQDC1-830 9 m (29.5 ft) M12 x 1<br>ø 14.5 6 5<br>MQDC1-850 15 m (49.2 ft)<br>MQDC1-806RA 2 m (6.5 ft) 32 Typ.<br>[1.26"]<br>MQDC1-815RA 5 m (16.4 ft)<br>MQDC1-830RA 9 m (29.5 ft) 30 Typ. 1 = White2 = Brown 5 = Gray6 = Pink<br>Right-Angle [1.18"] 3 = Green 7 = Blue<br>4 = Yellow 8 = Red<br>MQDC1-850RA 15 m (49.2 ft)<br>M12 x 1<br>ø 14.5 [0.57"]<br>8-Pin Double-Ended M12 Female to M12 Male Cordsets<br>Model Length Style Dimensions Pinout<br>MQDEC1-803SS 1 m (3.28 ft) 40 Typ.<br>MQDEC1-806SS 2 m (6.56 ft)<br>MQDEC1-810SS 3 m (9.84 ft) M12 x 1<br>ø 14.5<br>44 Typ. 1 = White<br>2 = Brown<br>3 = Green<br>MQDEC1-815SS 5 m (16.4 ft) Male Straight / 4 = Yellow<br>Female Straight M12 x 1 5 = Gray<br>ø 14.5 6 = Pink<br>7 = Blue<br>8 = Red<br>MQDEC1-830SS 9 m (29.5 ft) Female Male<br>1 2 2 1<br>MQDEC1-850SS 15 m (49.2 ft) 7 3 3 7<br>MQDEC1-8100SS 30.5 m (100 ft) 8 4 8 6<br>MQDEC1-8200SS 61 m (200 ft) 6 5 4 5<br>**----- End of picture text -----**<br> ## Mounting Brackets All measurements are listed in millimeters, unless noted otherwise. The measurements provided are subject to change. ## SMB30A - Right-angle bracket with curved slot for versatile orientation - Clearance for M6 (¼ in) hardware - Mounting hole for 30 mm sensor - 12-gauge stainless steel - CAD Files: DXF, PDF, IGS, STP Hole center spacing: A to B=40 Hole size: A=ø 6.3, B= 27.1 × 6.3, C=ø 30.5 **==> picture [67 x 67] intentionally omitted <==** **----- Start of picture text -----**<br> 45<br>C<br>61<br>B<br>A<br>69<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 11 of 17 27-Jan-26 TL70B Modular Tower Light Product Manual Accessories ## SMB30MM - 12-gauge stainless steel bracket with curved mounting slots for versatile orientation - Clearance for M6 (¼ in) hardware - Mounting hole for 30 mm sensor - CAD Files: DXF, PDF, IGS, STP Hole center spacing: A=51, A to B=25.4 Hole size: A=42.6 × 7, B=ø 6.4, C=ø 30.1 **==> picture [90 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> 70 57<br>C<br>57<br>B<br>A<br>**----- End of picture text -----**<br> ## SMBAMS30P - Flat SMBAMS series bracket - 30 mm hole for mounting sensors - Articulation slots for 90°+ rotation - 12-gauge 300 series stainless steel - • CAD Files: DXF, PDF, IGS, STP **==> picture [46 x 49] intentionally omitted <==** **----- Start of picture text -----**<br> 45<br>C<br>A<br>93<br>B<br>**----- End of picture text -----**<br> Hole center spacing: A=26.0, A to B=13.0 Hole size: A=26.8 × 7.0, B=ø 6.5, C=ø 31.0 **==> picture [442 x 294] intentionally omitted <==** **----- Start of picture text -----**<br> 85 60<br>• Single 30 mm hole 45<br>• 8 gauge steel, black finish (powder coat)<br>• Front surface for customer-applied labels<br>• CAD Files: DXF, PDF, IGS, STP 80 B<br> A = ø 7 , B = ø 30 A<br>55<br>• Direct mounting of stand-off pipe, with common bracket type 35 38.25<br>• Zinc-plated steel<br>• 1/2-14 NPSM nut<br>• Mounting distance from the wall to the center of the 1/2-14 NPSM nut is 35 mm<br>• CAD Files: DXF, PDF, IGS, STP 57<br>Hole center spacing: 20.0 2X Ø9<br>65<br>45<br>• Direct mounting of stand-off pipe, with common bracket type 38.25<br>• Zinc-plated steel<br>• 1/2-14 NPSM nut<br>• Mounting distance from the wall to the center of the 1/2-14 NPSM nut is 45 mm<br>• CAD Files: DXF, PDF, IGS, STP 81<br>Hole center spacing: 35.0 2X Ø11<br>**----- End of picture text -----**<br> ## SSA-MBK-EEC1 Hole size: A = ø 7 , B = ø 30 ## LMBE12RA35 Hole center spacing: 20.0 ## LMBE12RA45 Hole center spacing: 35.0 page 12 of 17 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 27-Jan-26 TL70B Modular Tower Light Product Manual Accessories ## Elevated Mount System Example Assembly for a TL70 Tower Light **==> picture [500 x 197] intentionally omitted <==** **----- Start of picture text -----**<br> Adapter/<br>Cover<br>This example uses:<br>1. Adapter/Cover (SA-M30 shown)<br>Pipe 2. Pipe<br>3. Mounting Base (SA-FFB12 shown)<br>Other compatible parts are listed in the following tables.<br>Mounting<br>Base<br>**----- End of picture text -----**<br> ## Adapters/Covers - Adapter/Cover Model Description SA-M30 - Black polycarbonate • Streamlined black PC or Gray PC thread cover • Covers the outer M30 threads on the light's base • Typically used for the TL70 Tower Light and K90 series - SA-M30C - Gray polycarbonate • Mounting hardware included • CAD files: DXF, PDF, IGS, STP **==> picture [200 x 38] intentionally omitted <==** ## Pipes Black Anodized Aluminum, ½ in. NPT Clear Anodized Aluminum, ½ in. NPT Description Pipe Models Pipe Models SOP-E12-150A , 150 mm (6 in) long SOP-E12-150AC , 150 mm (6 in) long • Elevated-use stand-off pipe • Threaded at both ends SOP-E12-300A , 300 mm (12 in) long SOP-E12-300AC , 300 mm (12 in) long • Compatible with most industrial environments SOP-E12-600A , 600 mm (24 in) long - • CAD Files: ◦ SOP-E12-150A : DXF, PDF, IGS, STP ◦ SOP-E12-300A : DXF, PDF, IGS, STP SOP-E12-900A , 900 mm (36 in) long SOP-E12-900AC , 900 mm (36 in) long ◦ SOP-E12-600A : DXF, PDF, IGS, STP ◦ SOP-E12-900A : DXF, PDF, IGS, STP ## Bottom Covers and Mounting Bases **==> picture [500 x 97] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting Base Model Description<br>SA-E12M30 - Black acetal<br>• Streamlined black acetal or white UHMW mounting base<br>adapter/cover<br>• Adapter from ½ in. NPSM/DN15 pipe to 30 mm (1-3/16 in)<br>drilled hole<br>SA-E12M30C - White UHMW • Mounting hardware included<br>• CAD files: DXF, PDF, IGS, STP<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 13 of 17 27-Jan-26 TL70B Modular Tower Light Product Manual Accessories **==> picture [500 x 398] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting Base Model Description<br>• Die-cast zinc base with black paint<br>• Elevated-use stand-off pipes (½ in, NPSM/DN15)<br>SA-F12 • M5 mounting hardware and nitrile gasket included<br>• CAD files: DXF, PDF, IGS, STP<br>Mounting Base Model Description<br>• Black polycarbonate<br>• Elevated-use stand-off pipes (½ in, NPSM/DN15)<br>SA-F12-3 • M4 mounting hardware and nitrile blend gasket included<br>• CAD files: DXF, PDF, IGS, STP<br>Mounting Base Model Description<br>SA-FFB12 - Black polycarbonate<br>• For use with ½ in. stand-off pipes<br>• 110° rotation<br>SA-FFB12C - Gray • Stainless steel hardware<br>polycarbonate • CAD files: DXF, PDF, IGS, STP<br>Mounting Base Model Description<br>• Black polycarbonate<br>• Foldable stand model with upright and 90° folding states<br>SOKTL150R4 • Elevated-use stand-off pipes (½ in, NPSM/DN15)<br>• Mounting hardware included<br>• CAD files: DXF, PDF, IGS, STP<br>**----- End of picture text -----**<br> ## LMB Sealed Right Angle Bracket Model Description Construction LMB30RA Direct-Mount Models: Bracket kit with base, CAD Files: DXF, PDF, IGS, 30 mm adapter, set screw, fasteners, O-rings, Black polycarbonate STP and gaskets. Pipe-Mount Models: Bracket kit with base, LMBE12RA ½-14 pipe adapter, set screw, fasteners, O- CAD Files: DXF, PDF, IGS, Black polycarbonate rings, and gaskets. For use with stand-off STP pipe (listed and sold separately). **==> picture [119 x 97] intentionally omitted <==** page 14 of 17 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 27-Jan-26 TL70B Modular Tower Light Product Manual Accessories ## Top Replacement Cover C-TL70 Replacement Top Cover - Black polycarbonate housing - Fits TL70 tower lights - • IP65 rated - CAD Files: DXF, PDF, IGS, STP © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 15 of 17 27-Jan-26 TL70B Modular Tower Light Product Manual ## Chapter Contents Clean with Mild Detergent and Warm Water ...................................................................................................................................................... 16 Repairs ............................................................................................................................................................................................................... 16 Contact Us.......................................................................................................................................................................................................... 16 Banner Engineering Corp Limited Warranty....................................................................................................................................................... 16 ## Chapter 6 Product Support and Maintenance ## Clean with Mild Detergent and Warm Water Wipe down the device with a soft cloth dampened with a mild detergent and warm water solution. Do not use any other chemicals for cleaning. ## Repairs Contact Banner Engineering for troubleshooting of this device. Do not attempt any repairs to this Banner device; it contains no field-replaceable parts or components. If the device, device part, or device component is determined to be defective by a Banner Applications Engineer, they will advise you of Banner's RMA (Return Merchandise Authorization) procedure. IMPORTANT: If instructed to return the device, pack it with care. Damage that occurs in return shipping is not covered by warranty. ## Contact Us Banner Engineering Corp. | 9714 Tenth Avenue North | Plymouth, MN 55441, USA | Phone: + 1 888 373 6767 For worldwide locations and local representatives, visit www.bannerengineering.com. ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 16 of 17 27-Jan-26 ## LinkedIn ## X ## Facebook Instagram © 2026. All rights reserved. www.bannerengineering.com
Updated at April 29, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →