ATK-VR81Q6
SAFETY RELAYS
- Manufacturer: BANNER ENGINEERING
- Product type: Safety Relays
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 715.15 € |
| Current stock | 10+ |
| Lead time | 30 days |
TWO-HAND CONTROL MODULES
## Two-Hand Control Modules Two-Hand Control Modules
## DUO-TOUCH[®] SG Two-Hand Control Modules . . page 87
- Monitors STB buttons or other actuators.
- Delivers highest level of safety for two-hand controls.
- Offers choice of operating voltages.
## STB Self-Checking Touch Buttons . . . . . . . . . . . . . . . . . . page 94
- Delivers highest level of safety for two-hand controls.
- Self-checks for internal problems.
- Features ergonomic design to prevent repetitive motion stress.
## ® DUO-TOUCH Two-Hand Control Modules . . . . . . . . . . . . . page 97
- Monitors OTB buttons or mechanical push buttons.
- Requires two hands on the controls.
- Responds in milliseconds.
## OTB Optical Touch Buttons . . . . . . . . . . . . . . . . . . . . . . page 100
- Replaces mechanical push buttons.
- Features ergonomic design to prevent repetitive motion stress.
- Senses light, not pressure.
_More information online at_ bannerengineering.com
85
> TWO-HAND CONTROL MODULES TY
## Selection Chart Lo
|**DUO-TOUCH® SG**|**AT-FM-10K**||Page 87|IIIC|24V ac/dc|2 STB*|**2 NO**|6 amps|—|22.5 mm|
|---|---|---|---|---|---|---|---|---|---|---|
||**AT-GM-13A**||Page 87|IIIC|115V ac/<br>24V dc|2 STB*|**4 NO**|6 amps|1 NPN,<br>1 PNP &<br>1 NC|45 mm|
||**AT-HM-13A**|hi|Page 87|IIIC|230V ac/<br>24V dc|2 STB*|**4 NO**|6 amps|1 NPN,<br>1 PNP &<br>1 NC|45 mm|
||**AT-GM-11KM**||Page 87|IIIC|115V ac/<br>24V dc|2 STB*<br>&<br>Muting|**2 NO**|6 amps|1 NPN,<br>1 PNP &<br>1 NC|67.5 mm|
||**AT-HM-11KM**||Page 87|IIIC|230V ac/<br>24V dc|2 STB*<br>&<br>Muting|**2 NO**|6 amps|1 NPN,<br>1 PNP &<br>1 NC|67.5 mm|
|**DUO-TOUCH**<br>**®**|**AT-AM-2A**|2|Page 97|IIIA/B|115V ac|2 OTB**|**2 NO**|4 amps|1 NC|45 mm|
||**AT-BM-2A**|s|Page 97|IIIA/B|230V ac|2 OTB**|**2 NO**|4 amps|1 NC|45 mm|
NC = Normally Closed, NO = Normally Open
- May also use two mechanical push buttons, each with one normally open (NO) and one normally closed (NC) contact (Form C). See data sheets for details.
- ** May also use two mechanical push buttons, each with one normally open (NO) contact. See data sheets for details.
86 _More information online at_ bannerengineering.com
TWO-HAND CONTROL MODULES
DUO-TOUCH[®] SG Modules
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## DUO-TOUCH ® SG Two-hand Control Modules, STB Compatible
- Modules work with Banner STB self-checking touch buttons or can be retrofitted with existing mechanical palm buttons to create a complete, ergonomic two-hand control system.
- To ensure reliability, modules have a diverse-redundant microcontroller circuit and multiple redundant, force-guided (mechanically linked) output contacts.
- Anti-tiedown logic requires that both touch buttons are activated within one-half second of each other.
- Modules meet Safety Category 4 per ISO 13849-1 (EN 954-1) and functional Type IIIC two-hand control per EN 574.
- Removable terminal blocks allow convenient wiring and exchanging of modules without rewiring.
- Optional mute inputs allow release of actuating buttons during the non-hazardous portion of the machine cycle.
- Available kits include module and two STB touch buttons.
- STB touch buttons are far more ergonomic than mechanical and difficult-to-activate capacitive buttons.
Use with STB Self-Checking Touch Buttons, _**Page 94 .**_
## AT-FM-10K Models
- 24V ac/dc
- 2 dual NO/NC inputs
- 2 safety outputs, 6 amps _**Page 88.**_
**==> picture [267 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
• Available in ac and dc voltages: 24V ac/dc, 115V ac/24V dc<br>or 230V ac/24V dc.<br>—— QD CABLES<br>4- & 5-Pin Euro +<br>a 4- & 5-Pin Mini<br>PAGE 174<br>BRACKETS<br>—=<br>PAGE190<br>**----- End of picture text -----**<br>
## AT-GM/HM-13A Models
## AT-GM/HM-11KM Models
- 115V ac/24V dc (GM)
- 115V ac/24V dc (GM)
- 230V ac/24V dc (HM)
- 230V ac/24V dc (HM)
- 2 dual NO/NC inputs
- 2 NO/NC inputs
- 4 safety outputs, 6 amps
- 2 muting inputs
- 1 safety stop interface
- Auxiliary outputs _**Page 88.**_
- 2 safety outputs
- Auxiliary outputs _**Page 88.**_
_More information online at_ bannerengineering.com
87
TWO-HAND CONTROL MODULES
DUO-TOUCH[®] SG Modules
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## **DUO-TOUCH® SG Two-Hand Control Modules, STB Compatible**
- || _24V ac/dc, 115V ac/24V dc, or 230V ac/24V dc_
_Four green and one red LED indicators_
- _Minimum NEMA 3 (IEC IP20) polycarbonate housing_
_Muting optional_
- _35 millisecond output response time_
**==> picture [266 x 120] intentionally omitted <==**
**----- Start of picture text -----**<br>
Detailed<br>Dimensions<br>84 mm<br>118 mm<br>22.5 mm<br>**----- End of picture text -----**<br>
## AT-FM-10K Model
**==> picture [24 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
84 mm<br>**----- End of picture text -----**<br>
**==> picture [137 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
84 mm<br>118 mm<br>45 mm<br>**----- End of picture text -----**<br>
**==> picture [101 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
118 mm<br>67.5 mm<br>**----- End of picture text -----**<br>
AT-..M-13A Models (AT-GM-13A shown)
AT-..M-11KM Models (AT-GM-11KM shown)
## **DUO-TOUCH® SG Two-Hand Control Modules, STB Compatible**
_Download PDF_
|**AT-FM-10K**|24V ac/dc|2 STB*|**2 NO**|6 amps|—|—|Removable|TD001<br>(p. 239)|64137|
|---|---|---|---|---|---|---|---|---|---|
|**AT-GM-13A**|115V ac/24V dc|2 STB*|**4 NO**||1 NPN,<br>1 PNP &<br>1 NC|—|Removable|TD001<br>(p. 239)|67241|
|**AT-HM-13A**|230V ac/24V dc|||||||||
|**AT-GM-11KM**|115V ac/24V dc|2 STB*<br>&<br>Muting|**2 NO**||1 NPN,<br>1 PNP &<br>1 NC|Yes|Removable|TD002<br>(p. 239)|109782|
|**AT-HM-11KM**|230V ac/24V dc|||||||||
NC = Normally Closed, NO = Normally Open
* May also use two mechanical push buttons, each with one normally open (NO) and one normally closed (NC) contact (Form C). See data sheets for details. NOTE: Kits are available which include one DUO-TOUCH SG Safety Module and two STB Touch Buttons. STB Touch Buttons are also available separately. See page 94.
88 _More information online at_ bannerengineering.com ~~ot~~
TWO-HAND CONTROL MODULES
DUO-TOUCH[®] SG Modules ~~Lo~~
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## **DUO-TOUCH® SG Kits — Solid-State STB Touch Buttons (Meets Category IIIC)**
**Kit Components**
|**Kit**|**Kit Components**|**Kit Components**|**Kit Components**|**Kit Components**|**Kit Components**|
|---|---|---|---|---|---|
|**Includes 2 STB**<br>**Touch Buttons &**<br>**a DUO-TOUCH SG**<br>**Safety Module**|**DUO-TOUCH SG**<br>**Safety Module**<br>~~Pf~~|**Supply**<br>**Voltage**<br>~~Pf~~|**Safety**<br>**Outputs**<br>~~Pf~~|**STB Touch Buttons**<br>~~Pf~~||
|||||**Model**<br>~~Pf~~|**Cable***|
|**ATK-VP6**|**AT-FM-10K**|24V ac/dc|**2 NO**|**STBVP6**|2 m|
|**ATK-VP6Q**||||**STBVP6Q**|4-Pin Mini QD|
|**ATK-VP6Q5**||||**STBVP6Q5**|4-Pin Euro QD|
|**ATGMK-VP6**|**AT-GM-13A**<br>~~2~~|115V ac/24V dc|**4 NO**|**STBVP6**|2 m|
|**ATGMK-VP6Q**||||**STBVP6Q**|4-Pin Mini QD|
|**ATGMK-VP6Q5**||||**STBVP6Q5**<br>~~a~~|4-Pin Euro QD|
|**ATHMK-VP6**|**AT-HM-13A**<br>~~2~~|230V ac/24V dc|**4 NO**|**STBVP6**<br>~~a~~|2 m|
|**ATHMK-VP6Q**||||**STBVP6Q**<br>~~a~~|4-Pin Mini QD|
|**ATHMK-VP6Q5**||||**STBVP6Q5**|4-Pin Euro QD|
|**ATGMKM-VP6**|**AT-GM-11KM**|115V ac/24V dc|**2 NO**|**STBVP6**|2 m|
|**ATGMKM-VP6Q**||||**STBVP6Q**|4-Pin Mini QD|
|**ATGMKM-VP6Q5**||||**STBVP6Q5**|4-Pin Euro QD|
|**ATHMKM-VP6**|**AT-HM-11KM**|230V ac/24V dc|**2 NO**|**STBVP6**|2 m|
|**ATHMKM-VP6Q**||||**STBVP6Q**|4-Pin Mini QD|
|**ATHMKM-VP6Q5**||||**STBVP6Q5**|4-Pin Euro QD|
NC = Normally Closed, NO = Normally Open
- For 9 m cable, add suffix **W/30** to the 2 m model number (example, **ATK-VP6 W/30** ). A model with a QD requires a mating cable. Order QD cables separately (see pages 174 & 178).
_More information online at_ bannerengineering.com
89
TWO-HAND CONTROL MODULES
DUO-TOUCH[®] SG Modules ~~Lo~~
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## **DUO-TOUCH® SG Kits – e/m Relay STB Touch Buttons (Meets Category IIIC)**
|**Kit**<br>~~|~~|**Kit Components**<br>~~||~~<br>~~|~~|**Kit Components**<br>~~||~~<br>~~|~~|**Kit Components**<br>~~||~~<br>~~|~~|**Kit Components**<br>~~||~~<br>~~|~~|**Kit Components**<br>~~||~~<br>~~|~~|
|---|---|---|---|---|---|
|**Includes 2 STB**<br>**Touch Buttons &**<br>**a DUO-TOUCH SG**<br>**Safety Module**<br>~~|~~|**DUO-TOUCH SG**<br>**Safety Module**<br>~~||~~<br>|**Supply**<br>**Voltage**<br>~~|~~|**Safety**<br>**Outputs**<br>|**STB Touch Buttons**<br>||
|||||**Model**<br>|**Cable***|
|**ATK-VR81**<br>~~|~~|**AT-FM-10K**<br>~~| |~~<br>~~J~~|24V ac/dc<br>~~|J~~|**2 NO**<br>~~J~~|**STBVR81**<br>~~J~~|2 m|
|**ATK-VR81Q**||||**STBVR81Q**<br>~~J~~|5-Pin Mini QD|
|**ATK-VR81Q6**||||**STBVR81Q6**<br>~~J~~<br>~~—~~|5-Pin Euro QD|
|**ATGMK-VR81**|**AT-GM-13A**<br>~~es~~|115V ac/24V dc<br>~~es~~|**4 NO**|**STBVR81**<br>~~a~~|2 m|
|**ATGMK-VR81Q**||||**STBVR81Q**<br>~~a~~|5-Pin Mini QD|
|**ATGMK-VR81Q6**||||**STBVR81Q6**<br>~~a~~|5-Pin Euro QD|
|**ATHMK-VR81**|**AT-HM-13A**<br>~~se~~|230V ac/24V dc<br>~~se~~|**4 NO**|**STBVR81**|2 m|
|**ATHMK-VR81Q**||||**STBVR81Q**|5-Pin Mini QD|
|**ATHMK-VR81Q6**||||**STBVR81Q6**|5-Pin Euro QD|
|**ATGMKM-VR81**|**AT-GM-11KM**|115V ac/24V dc|**2 NO**|**STBVR81**<br>~~a~~|2 m|
|**ATGMKM-VR81Q**||||**STBVR81Q**|5-Pin Mini QD|
|**ATGMKM-VR81Q6**||||**STBVR81Q6**<br>~~—~~|5-Pin Euro QD|
|**ATHMKM-VR81**|**AT-HM-11KM**|230V ac/24V dc|**2 NO**|**STBVR81**|2 m|
|**ATHMKM-VR81Q**||||**STBVR81Q**|5-Pin Mini QD|
|**ATHMKM-VR81Q6**||||**STBVR81Q6**|5-Pin Euro QD|
NC = Normally Closed, NO = Normally Open
- For 9 m cable, add suffix **W/30** to the 2 m model number (example, **ATK-VR81 W/30** ). A model with a QD requires a mating cable. Order QD cables separately (see pages 175 & 178).
90 _More information online at_ bannerengineering.com
TWO-HAND CONTROL MODULES
DUO-TOUCH[®] SG Modules
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## **DUO-TOUCH® SG AT-..M-13A Modules Specifications**
|**Supply Voltage and Current**|**Model AT-GM-13A:**115V ac, ±15%; 50/60 Hz & 24V dc, ±15%, 10% max. ripple<br>**Model AT-HM-13A:**230V ac, ±15%; 50/60 Hz & 24V dc, ±15%, 10% max. ripple|
|---|---|
|**Supply Protection Circuitry**|Protected against transient voltages and reverse polarity|
|**Safety Outputs**|Outputs (K1 and K2): four redundant (total of eight) forced-guided safety relay contacts<br>**Contact ratings:**<br>**Max. voltage:**250V ac or 250V dc<br>**Min. voltage:**15V ac/dc<br>**Max. current:**6A ac or dc (resistive load)<br>**Min. current:**30 mA<br>**Max. power:**1500 VA, 200 watts<br>**Min. power:**5 VA, 5 watts<br>**Mechanical life:**50,000,000 operations<br>**Electrical life:**150,000 cycles (typically @ 1.5 kVA switching power)<br>**NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across**<br>**load. Never install suppressors across output contacts.**|
|**Auxiliary Supply Voltage**<br>**(for Solid-State outputs)**|24V dc @ 1A<br>(between Y30 & Y31)|
|**Auxiliary Solid-State Output**<br>**Current**|500 mA max., short circuit protected<br>(Y32 or Y31)|
|**Output Response Time**|35 milliseconds max. ON/OFF|
|**Input Requirements**|Outputs from actuating devices (1 NO and 1 NC) must each be capable of switching 20 mA @ 12V dc.|
|**Simultaneity Monitoring**<br>**Period**|≤500 milliseconds|
|**Z1/Z2 Courtesy Voltage**|24V dc @ 150 mA (for STB button power)|
|**External Device Monitoring**<br>**(EDM)**|One pair of terminals (Y1 and Y2) are provided to monitor the state of external devices controlled by the safety<br>outputs. Each device must be capable of switching 15 to 30V dc at 10-50 mA.|
|**Status Indicators**|**4 green LED indicators:**<br>**1 red LED indicator:**<br>Power ON<br>Fault<br>Input 1 energized<br>Input 2 energized<br>Output|
|**Housing**|Polycarbonate. Rated NEMA 1; IEC IP20|
|**Mounting**|Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated<br>NEMA 3 (IEC IP54), or better.|
|**Vibration Resistance**|10 to 55 Hz @ 0.35 mm displacement per IEC 68-2-6|
|**Operating Conditions**|**Temperature:**0° to +50° C<br>**Relative humidity:**90% @ +50° C (non-condensing)|
|**Safety Category**|4 per ISO 13849-1 (EN 954-1); Type IIIC per ISO 13851 (EN 574)|
|**Certifications**|For a list of certifications see page 236.|
|**Wiring Diagrams**|**AT-..M-13A models:**WD032 (p. 264)<br>**AT-..M-13A to STB Buttons:**WD034 (p. 265)|
_More information online at_ bannerengineering.com
91
TWO-HAND CONTROL MODULES
DUO-TOUCH[®] SG Modules
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS |
## **DUO-TOUCH® SG AT-FM-10K Modules Specifications**
|**Supply Voltage and Current**|24V ac/dc ±15% @ 150 mA|
|---|---|
|**Supply Protection Circuitry**|Protected against transient voltages and reverse polarity|
|**Safety Outputs**|Outputs (K1 and K2): two redundant (total of four) forced-guided safety relay contacts<br>**Contacts:**AgNi, 5 µm gold-plated<br>**Low Current Rating:**<br>**Caution: The 5 µm gold-plated contacts allow the switching of low current/low voltage.**<br>To preserve the gold plating on the contacts, the following max. values should not be exceeded at any time:<br>**Min. voltage:**1V ac/dc<br>**Max. voltage:**60V<br>**Min. current:**5 mA ac/dc<br>**Max. current:**300 mA<br>**Min. power:**5 mW (5 mVA)<br>**Max. power:**7 W (7 VA)<br>**High Current Rating:**<br>If higher loads must be switched through one or more of the contacts, the minimum and maximum values of<br>the contact(s) changes to:<br>**Max. voltage:**250V ac/dc<br>**Min. voltage:**15V ac/dc<br>**Max. current:**6 A ac or dc (resistive load)**Min. current:**30 mA<br>**Max. power:**200 W (1,500 VA)<br>**Min. power:**5 W (5 VA)<br>**Mechanical life:**50,000,000 operations<br>**Electrical life:**150,000 operations typical, @ 200 W (1,500 VA) switched power, resistive load.<br>**NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across**<br>**load. Never install suppressors across output contacts.**|
|**Output Response Time**|35 milliseconds max. ON/OFF|
|**Input Requirements**|Outputs from actuating devices (1 NO and 1 NC) must each be capable of switching 20 mA @ 12V dc.|
|**Simultaneity Monitoring Period**|≤500 milliseconds|
|**External Device Monitoring**<br>**(EDM)**|One pair of terminals (Y1 and Y2) are provided to monitor the state of external devices controlled by the safety<br>outputs. Each device must be capable of switching 15 to 30V dc at 10-50 mA.|
|**Status Indicators**|**4 green LED indicators:**<br>**1 red LED indicator:**<br>Power ON<br>Fault<br>Input 1 energized<br>Input 2 energized<br>Output|
|**Housing**|Polycarbonate. Rated NEMA 1; IEC IP20|
|**Mounting**|Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated<br>NEMA 3 (IEC IP54), or better.|
|**Vibration Resistance**|10 to 55 Hz @ 0.35 mm displacement per IEC 68-2-6|
|**Operating Conditions**|**Temperature:**0° to +50° C<br>**Relative humidity:**90% @ +50° C (non-condensing)|
|**Safety Category**|4 per ISO 13849-1 (EN 954-1); Type IIIC per ISO 13851 (EN 574)|
|**Certifications**|For a list of certifications see page 236.|
|**Wiring Diagrams**|**AT-FM-10K models:**WD029 (p. 262)|
92 _More information online at_ bannerengineering.com
TWO-HAND CONTROL MODULES
DUO-TOUCH[®] SG Modules
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
|**Supply Voltage and Current**|**AT-GM-11KM:**115V ac, ± 15%; 50/60Hz & 24V dc, +/- 15%, 10% max. ripple<br>**AT-HM-11KM:**230V ac, ± 15%; 50/60Hz & 24V dc, +/- 15%, 10% max. ripple|
|---|---|
|**Power Consumption**|Approx. 4 W / 7 VA|
|**Supply Protection Circuitry**|Protected against transient voltages and reverse polarity|
|**Safety Outputs**|**Outputs (K1 and K2):**two redundant (total of four) safety relay (forced-guided) contacts<br>**Contact ratings:**<br>**Max. voltage:**250V ac or 250V dc<br>**Max. current:**6A ac or dc (resistive load)<br>**Max. power:**1500 VA, 200 watts<br>**Mechanical life:**50,000,000 operations<br>**Electrical life:**150,000 cycles (typically @ 1.5 kVA switching power)<br>**NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across**<br>**load. Never install suppressors across output contacts.**|
|**Auxiliary Supply Voltage**<br>**(for solid-state outputs)**|24V dc @ 1A<br>(applied between Y30 & Y31)|
|**Auxiliary Solid-State**<br>**Output Current**|500 mA max., short circuit protected, Y32 is a PNP output, Y33 is an NPN output|
|**Output Response Time**|35 milliseconds max. ON/OFF|
|**Input Requirements**|Outputs from actuating devices must each be capable of switching up to 20 mA @ 12V dc.|
|**Simultaneity Monitoring**<br>**Period**|≤500 milliseconds|
|**Z1/Z2 Courtesy Voltage**|24V dc @ 150 mA (for STB button power, separate from Auxiliary output, unregulated)|
|**External Device Monitoring**<br>**(EDM)**|One pair of terminals (Y1 and Y2) are provided to monitor the state of external devices controlled by<br>the safety outputs. Each device must be capable of switching 15 to 30V dc at 10-50 mA.|
|**Muting Device Inputs (M1, M2)**|The muting devices work as a pair (M1 and M2). The simultaneity requirement is that they be “closed”<br>within 3 seconds of each other to initiate a mute condition or allow a mute cycle, assuming all other<br>conditions are met. Each muting device must be capable of switching 15 to 30V dc at 10-50 mA.|
|**Mute Enable Input (ME)**|Mute Enable input must be closed in order to start a mute cycle. Opening this input after a mute cycle<br>has begun has no effect. The switching device must be capable of switching 15 to 30V dc at 10-50 mA.|
|**Safety Stop Interface (SSI)**|This input consists of two concurrent channels (SSI-A and SSI-B) and is always active. Any time<br>either or both channels open, the Safety Outputs will go OFF. When using the SSI, the external device<br>must be capable of switching 15 to 30V dc at 10-50 mA.|
|**Status Indicators**|**6 green LED indicators**<br>**1 red LED indicator**<br>Power ON<br>Fault<br>Input 1 energized<br>Input 2 energized<br>SSI inputs closed<br>Muting activated<br>Output|
|**Housing**|Polycarbonate. Rated NEMA 1; IEC IP20|
|**Mounting**|Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated<br>NEMA 3 (IEC IP54), or better.|
|**Vibration Resistance**|10 to 55Hz @ 0.35 mm displacement per IEC 68-2-6|
|**Operating Conditions**|**Temperature:**0° to +50° C<br>**Relative humidity:**90% @ +50° C (non-condensing)|
|**Safety Category**|4 per ISO 13849-1; Type IIIC per ISO 13851 (EN 574)|
|**Certifications**|For a list of certifications see page 236.|
|**Wiring Diagrams**|**AT-..M-11KM models:**WD033 (p. 264)<br>**AT-..M-11KM to STB Buttons:**WD034 (p. 265)|
_More information online at_ bannerengineering.com
93
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
® **QD CABLES** 4- & 5-Pin Euro + 4- & 5-Pin Mini 3 **PAGE 174**
## TWO-HAND CONTROL MODULES STB Buttons STB Self-Checking Touch Buttons • Provides highest level of safety for two-hand control input devices, per independent certification tests. nn
- Provides highest level of safety for two-hand control input devices, per independent certification tests.
- Provides redundant microprocessor and optical path.
- Responds to a finger blocking light rather than to pressure.
- Features ergonomic design to prevent repetitive motion stress.
- Includes yellow field cover to prevent unintended switching.
- Immune to ambient light, EMI and RFI.
- Available with e/m relays rated for 1 amp switch capacity or solid-state outputs rated for 150 mA.
- Withstands exposure to a variety of chemicals, depending on model.
- **QD CABLES**
- 4- & 5-Pin Euro + 4- & 5-Pin Mini **PAGE 174 BRACKETS**
- =) **PAGE 190 STB Self-Checking Touch Buttons** _EN 574-compliant_ **59.9 mm**
- _LED power, output and fault indicators_ **43.2 mm**
- ~~—e~~ _10-30V dc or 20-30V ac/dc 2 m or 9 m integral cable or quick-disconnect fitting_ o
- _Housing sealed to IEC IP66_
**==> picture [30 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
57.1 mm<br>**----- End of picture text -----**<br>
**==> picture [44 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Detailed<br>Dimensions<br>**----- End of picture text -----**<br>
- _Optional field cover colors_
**==> picture [30 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
96.1 mm<br>**----- End of picture text -----**<br>
STB models
**==> picture [24 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
51 mm<br>**----- End of picture text -----**<br>
**==> picture [24 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
69 mm<br>**----- End of picture text -----**<br>
**==> picture [50 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
STB models<br>with cover<br>**----- End of picture text -----**<br>
94 _More information online at_ bannerengineering.com
TWO-HAND CONTROL MODULES
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
STB Buttons
**STB Self-Checking Buttons – Solid-State Outputs, 10-30V dc** _DownloadPDF_ **Upper Solid-State Data Models Cable* Housing Outputs Sheet STBVP6** 2 m **STBVP6Q** 4-Pin Mini QD Polysulfone **STBVP6Q5** 4-Pin Euro QD **2 Complementary PNP** 64136 **STBVP6L** 2 m **(1 ON, 1 OFF) STBVP6LQ** 4-Pin Mini QD Polycarbonate **STBVP6LQ5** 4-Pin Euro QD **STB Self-Checking Buttons – e/m Relay Outputs, 20-30V ac/dc** _Download_ ~~aT~~ _PDF_ **Upper e/m Relay Data Models Cable* Housing Outputs Sheet STBVR81** 2 m **STBVR81Q** 5-Pin Mini QD Polysulfone DUO-TOUCH® **STBVR81Q6** 5-Pin Euro QD **2 Complementary SPST** 64136 MODULES **STBVR81L** 2 m **(1 NC, 1 NO)** OTB BUTTONS **STBVR81LQ** 5-Pin Mini QD Polycarbonate **STBVR81LQ6** 5-Pin Euro QD ~~TT~~ NC = Normally Closed, NO = Normally Open * For 9 m cable, add suffix **W/30** to the 2 m model number (example, **STBVP6 W/30** ). A model with a QD requires a mating cable (see pages 174-175 & 178).
|**Supply Voltage and Current**|**STBVP6 Models:**10 to 30V dc; Power Consumption: approx. 1.8 W @ 24V dc (with no output load)<br>**STBVR81 Models:**20 to 30V ac/dc; Power Consumption: approx. 1.8 W/1.8 VA @ 24V ac/dc|
|---|---|
|**Supply Protection Circuitry**|Protected against transient voltages and reverse polarity|
|**Output Configuration**|**STBVP6 Models:**Complementary PNP (sourcing) open-collector transistors<br>**STBVR81 Models:**Complementary electromechanical relay|
|**Output Rating**|**STBVP6 Models (solid-state outputs):**<br>**Max. load:**150 mA<br>**On-state saturation voltage:** ≤15V @ full load<br>**Off-state leakage current:**less than 1 µA<br>**STBVR81 Models (electromechanical relay):**<br>**Max. voltage:**150V dc, 125V ac<br>**Max. switching current:**1A<br>**Max. resistive load power:**60 VA or 30 W dc<br>**Mechanical life of relay:**50,000,000<br>**Electrical life of relay:**150,000 (typically @ 1.5 kVA switching power)|
|**Output Protection**|All models protected against false pulse on power-up. Models with solid-state outputs have overload and short-<br>circuit protection.|
|**Response Time**|20 milliseconds ON/OFF|
|**Indicators**|**2 green LED indicators:**<br>**Power:**<br>ON – power applied<br>OFF – power off<br>**Output/fault:**ON – button is activated<br>OFF – button is deactivated<br>Flashing – internal fault or blocked button on power-up detected|
|**Construction**|Totally encapsulated, non-metallic enclosure. Black polysulfone or red polycarbonate upper housing (see<br>Application Notes, page 96); fiber-reinforced PBT polyester base. Electronics fully epoxy-encapsulated.<br>Supplied with polypropylene (TP) field cover.|
|**Environmental Rating**|Meets NEMA standards 1, 3, 4, 4X, 12 and 13; IEC IP66|
_More information online at_ bannerengineering.com
95
TWO-HAND CONTROL MODULES
STB Buttons
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## **STB Self-CheckinSTB Self-Checking Buttons Sg Buttons Specifications pecifications(cont’d)**
**Connections**
**Ambient Light Immunity**
**EMI/RFI Immunity Operating Conditions Application Notes**
PVC-jacketed 2 m cables standard on integral-cable kits; QD fitting, depending on model. Accessory QD mating cables required for QD models. QD cables are ordered separately. See pages 174-175 & 178. **STBVP6 Models:** 4-wire (4-pin Mini-style QD, add suffix **Q** or 4-pin Euro-style QD, add suffix **Q5** ) **STBVR81 Models:** 5-wire (5-pin Mini-style QD, add suffix **Q** or 5-pin Euro-style QD, add suffix **Q6** ) Integral 9 m cables are also available by adding suffix **W/30** to the 2 m model number.
Up to 100,000 lux
Immune to EMI and RFI noise sources per IEC 947-5-2
**Temperature:** 0° to +50° C
**Relative humidity:** 90% @ +50° C (non-condensing)
**STB Self-Checking Touch Buttons by themselves are not stand alone devices.** They must be installed to prevent accidental actuation (example, use of field covers). The environment in which they are installed must not adversely affect the means of actuation (example, severe contamination). See DUO-TOUCH SG module manuals for information on two-hand control safety applications.
## **Environmental considerations for models with polysulfone upper housings:**
The polysulfone upper housing will become brittle with prolonged exposure to outdoor sunlight. Window glass effectively filters ultraviolet light and provides excellent protection from sunlight. Avoid contact with strong alkalis. Clean periodically using mild soap solution and a soft cloth.
## **Environmental considerations for models with polycarbonate upper housings:**
Avoid prolonged exposure to hot water and moist high-temperature environments above 66° C. Avoid contact with aromatic hydrocarbons (such as xylene and toluene), halogenated hydrocarbons and strong alkalis. Clean periodically using mild soap solution and a soft cloth.
**Certifications Hookup Diagrams**
For a list of certifications see page 236.
**STB Solid State (PNP):** WD032 (p. 264) **STB e/m Relay:** WD034 (p. 265)
## **STB Self-Checking Buttons Field Covers**
_Download PDF_ **STB Self-Checking Buttons Field Covers Data Models Description Sheet OTC-1-BK** Black cover **OTC-1-GN** Green cover 28436 **OTC-1-RD** Red cover **OTC-1-YW** Yellow cover ~~ne~~ Field covers are designed to prevent inadvertent activation of optical touch buttons due to objects (loose clothing, debris, etc.) which might accidentally block their sensing beams. Field covers are constructed of rugged polypropylene and are highly resistant to abrasion and to damage by most chemicals. Standard model numbers are shipped with a yellow cover.
96 _More information online at_ bannerengineering.com
TWO-HAND CONTROL MODULES
DUO-TOUCH[®] Modules
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## DUO-TOUCH® Two-Hand Control Modules, OTB Compatible
- Monitors a pair of mechanical push buttons or OTB optical touch buttons.
- Permits machine operation only when the operator has both hands on the controls.
- Responds in 25 milliseconds or less.
- Meets Type IIIA/B requirements for Safety Category 1 and 3.
- Monitors the status of machine control elements.
**==> picture [41 x 41] intentionally omitted <==**
**----- Start of picture text -----**<br>
GE: 4- & 5-Pin Mini QD CABLES<br>PAGE 178<br>rs BRACKETS<br>**----- End of picture text -----**<br>
**==> picture [23 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
PAGE 190<br>**----- End of picture text -----**<br>
## **DUO-TOUCH® Two-Hand Control Modules, OTB Compatible**
_24V ac/dc, 115V ac, or 230V ac_
- |_| _Three green and one red LED indicators_
**==> picture [43 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Detailed<br>Dimensions<br>**----- End of picture text -----**<br>
- |_| _NEMA 1 polycarbonate housing Standard 35 mm DIN rail track mounting_
**==> picture [30 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
75.0 mm<br>**----- End of picture text -----**<br>
**==> picture [115 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
110.0 mm<br>45.0 mm<br>**----- End of picture text -----**<br>
AT-..M-2A Models (AT-FM-2A Module shown)
_More information online at_ bannerengineering.com ~~ee,~~
97
TWO-HAND CONTROL MODULES
DUO-TOUCH[®] Modules ~~[Lo~~
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## **DUO-TOUCH® Two-Hand Control Modules, OTB Compatible**
|**DUO-TOUCH® Two-Hand Control Modules, OTB Compatible**|**DUO-TOUCH® Two-Hand Control Modules, OTB Compatible**<br>**® Two-Hand Control Modules, OTB Compatible Two-Hand Control Modules, OTB Compatible**|**® Two-Hand Control Modules, OTB Compatible Two-Hand Control Modules, OTB Compatible**|**® Two-Hand Control Modules, OTB Compatible Two-Hand Control Modules, OTB Compatible**|**® Two-Hand Control Modules, OTB Compatible Two-Hand Control Modules, OTB Compatible**|**® Two-Hand Control Modules, OTB Compatible Two-Hand Control Modules, OTB Compatible**|**® Two-Hand Control Modules, OTB Compatible Two-Hand Control Modules, OTB Compatible**|||_Download_<br>_PDF_|
|---|---|---|---|---|---|---|---|---|---|
|**Models**|**Supply**<br>**Voltage**|**Inputs**|**Safety**<br>**Outputs**|**Output**<br>**Rating**|**Auxiliary**<br>**Outputs**|**Terminals**|**Timing**<br>**Diagrams**||**Data**<br>**Sheet**|
|**AT-AM-2A**|115V ac|||||||||
|**AT-BM-2A**<br>**AT-FM-2A**|230V ac<br>24V ac/dc|2 OTB*|**2 NO**|4 amps|1 NC|Fixed|TD003<br>(p. 239)||47550|
NC = Normally Closed, NO = Normally Open
- May also use two mechanical push buttons, each with one normally open (NO) contact. See data sheet for details.
NOTE: Kits are available which include one DUO-TOUCH Safety Module and two OTB Touch Buttons. OTB Touch Buttons are also available separately. See page 100.
## **DUO-TOUCH® Kits – e/m Relay OTB Touch Buttons**
|**Kit**|**Kit Components**|**Kit Components**|**Kit Components**|**Kit Components**|**Kit Components**|
|---|---|---|---|---|---|
|**Includes 2 OTB**<br>**Touch Buttons &**<br>**a DUO-TOUCH**<br>**Safety Module**|**DUO-TOUCH**<br>**Safety Module**|**Supply**<br>**Voltage**|**Safety**<br>**Outputs**|**OTB Touch Buttons**||
|||||**Model**|**Cable***|
|**AT-AM-K5**|**AT-AM-2A**|115V ac|**2 NO**|**OTBA5**|2 m|
|**AT-AM-K5Q**||||**OTBA5QD**|5-Pin Mini QD|
|**AT-BM-K5**|**AT-BM-2A**|230V ac|**2 NO**|**OTBB5**|2 m|
|**AT-BM-K5Q**||||**OTBB5QD**|5-Pin Mini QD|
|**AT-FM-K81**|**AT-FM-2A**|24V ac/dc|**2 NO**|**OTBVR81**|2 m|
|**AT-FM-K81Q**||||**OTBVR81QD**|5-Pin Mini QD|
NC = Normally Closed, NO = Normally Open
- For 9 m cable, add suffix **W/30** to the 2 m model number (example, **AT-AM-K5 W/30** ). A model with a QD requires a mating cable. QD cables are ordered separately (see page 178).
## **DUO-TOUCH® Kits – Solid-State OTB Touch Buttons**
|**Kit**|**Kit Components**|**Kit Components**|**Kit Components**|**Kit Components**|**Kit Components**|
|---|---|---|---|---|---|
|**Includes 2 OTB**<br>**Touch Buttons &**<br>**a DUO-TOUCH**<br>**Safety Module**|**DUO-TOUCH**<br>**Safety Module**|**Supply**<br>**Voltage**|**Safety**<br>**Outputs**|**OTB Touch Buttons**||
|||||**Model**|**Cable***|
|**AT-FM-K6**|**AT-FM-2A**|24V ac/dc|**2 NO**|**OTBVN6 &**<br>**OTBVP6**|2 m|
|**AT-FM-K6Q**||||**OTBVN6 &**<br>**OTBVP6**|4-Pin Mini QD|
- NC = Normally Closed, NO = Normally Open
- For 9 m cable, add suffix **W/30** to the 2 m model number (example, **AT-FM-K6 W/30** ). A model with a QD requires a mating cable. QD cables are ordered separately (see page 178).
98 _More information online at_ bannerengineering.com
TWO-HAND CONTROL MODULES
DUO-TOUCH[®] Modules
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## **DUO-TOUCH® Safety Modules Specifications**
|**Supply Voltage and Current**|**Model AT-AM-2A:**115V ac ±15% at 100 mA<br>**Model AT-BM-2A:**230V ac ±15% at 50 mA<br>**Model AT-FM-2A:**24V ac/dc ±15% at 250 mA|
|---|---|
|**Supply Protection Circuitry**|Protected against transient voltages and reverse polarity (dc hookup is without regard to polarity)|
|**Safety Outputs**|**Outputs (K1 and K2):**Two redundant (total of four) safety relay (forced-guided) contacts<br>**Contact ratings:**<br>**Max. voltage:**250V ac or 250V dc<br>**Max. current:**4A ac or dc (resistive load)<br>**Max. power:**1000 VA, 200 watts<br>**Mechanical life:**10,000,000 operations<br>**Electrical life:**100,000 cycles (typically @ 1.0 kVA switching power)<br>**NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across**<br>**load. Never install suppressors across output contacts.**<br>**Auxiliary Monitor Output (K3):**One non-safety relay contact<br>**Maximum switching voltage:**125V ac or dc<br>**Maximum switching current:**500 mA (resistive load)|
|**Output Response Time**|25 milliseconds maximum|
|**Input Requirements**|Outputs from actuating devices must each be capable of switching 40 to 100 mA @ 12 to 18V dc.|
|**Simultaneity Monitoring**<br>**Period**|300 milliseconds (typical)<br>< 500 milliseconds under single-fault conditions|
|**Status Indicators**|**3 green LED indicators:**<br>**1 red LED indicator:**<br>Power ON<br>Fault<br>K1 energized<br>K2 energized|
|**Housing**|Polycarbonate. Rated NEMA 1; IEC IP20|
|**Mounting**|Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated NEMA 3<br>(IEC IP54), or better.|
|**Vibration Resistance**|10 to 55Hz @ 0.35 mm displacement per IEC 68-2-6|
|**Operating Conditions**|**Temperature:**0° to +50° C<br>**Relative humidity:**90% @ +50° C (non-condensing)|
|**Safety Category**|1 and 3 per ISO 13849-1; Type IIIA/B per ISO 13851 (EN574)<br>(Dependent on hookup and installation of the hand controls)|
|**Certifications**|For a list of certifications see page 236.|
|**Wiring Diagrams**|**AT-..M-2A models:**WD035 (p. 266)<br>**AT-..M-2A to OTB Buttons:**WD037 (p. 267)|
_More information online at_ bannerengineering.com
99
TWO-HAND CONTROL MODULES
OTB Buttons ~~Ld~~
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## OTB
## Optical Touch Buttons
- Responds to a finger blocking light rather than to pressure.
- Features ergonomic design to prevent repetitive motion stress.
- Includes field cover to prevent unintended switching.
- Available with e/m relay rated for 7 amp switching capacity.
- Withstand exposure to a variety of chemicals, depending on model.
**==> picture [35 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
QD CABLES<br>4- & 5-Pin Mini<br>_a<br>PAGE 178<br>BRACKETS<br>—<br>PAGE 190<br>**----- End of picture text -----**<br>
## **OTB Optical Touch Buttons**
- _10 to 30V dc, 20 to 30V ac/dc, 105 to 130V ac, or 210-250V ac_
- _One red LED indicator_
**==> picture [143 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
59.9 mm<br>43.2 mm<br>™“ ><br>**----- End of picture text -----**<br>
_Detailed Dimensions_
- _Polysulfone or polycarbonate upper housing_
- ~~|~~ _2 m or 9 m integral cable or quick-disconnect fitting_
**==> picture [29 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
57.1 mm<br>**----- End of picture text -----**<br>
_Housing sealed to IEC IP66 Optional field cover colors_
OTB models
**==> picture [23 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
51 mm<br>**----- End of picture text -----**<br>
**==> picture [88 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
96.1 mm<br>_<br>69 mm<br>**----- End of picture text -----**<br>
**==> picture [49 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
OTB models<br>with cover<br>**----- End of picture text -----**<br>
100 _More information online at_ bannerengineering.com
TWO-HAND CONTROL MODULES
OTB Buttons
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
## **OTB Momentary Action – Solid-State Outputs, 10-30V dc**
_Download PDF_
|**OTBVN6**<br>**OTBVN6QD**|2 m<br>4-Pin Mini QD|Polysulfone|**NPN**|AT-FM-2A<br>(requires one NPN and<br>one PNP model OTB)|28436|
|---|---|---|---|---|---|
|**OTBVN6L**<br>**OTBVN6LQD**|2 m<br>4-Pin Mini QD|Polycarbonate||||
|**OTBVP6**<br>**OTBVP6QD**|2 m<br>4-Pin Mini QD|Polysulfone|**PNP**|||
|**OTBVP6L**<br>**OTBVP6LQD**|2 m<br>4-Pin Mini QD|Polycarbonate||||
## **OTB Momentary Action – e/m Relay Outputs, 20-30V ac or dc**
_Download PDF_
|**OTBVR81**<br>**OTBVR81QD**|2 m<br>5-Pin Mini QD|Polysulfone|**SPDT**|AT-FM-2A<br>(requires two OTBs)|28436|
|---|---|---|---|---|---|
|**OTBVR81L**<br>**OTBVR81LQD**|2 m<br>5-Pin Mini QD|Polycarbonate||||
## **OTB Momentary Action – e/m Relay Outputs, 120V ac**
_Download PDF_
|**OTBA5**<br>**OTBA5QD**|2 m<br>5-Pin Mini QD|Polysulfone|**SPDT**|AT-AM-2A<br>(requires two OTBs)|28436|
|---|---|---|---|---|---|
|**OTBA5L**<br>**OTBA5LQD**|2 m<br>5-Pin Mini QD|Polycarbonate||||
**OTB Momentary Action – e/m Relay Outputs, 220/240V ac** _DownloadPDF_ **Upper e/m Relay DUO-TOUCH Data Models Cable* Housing Outputs Compatibility Sheet OTBB5** 2 m Polysulfone **OTBB5QD** 5-Pin Mini QD AT-BM-2A **SPDT** 28436 (requires two OTBs) **OTBB5L** 2 m Polycarbonate **OTBB5LQD** 5-Pin Mini QD ~~TT~~
* For 9 m cable, add suffix **W/30** to the 2 m model number (example, **OTBVN6 W/30** ). A model with a QD requires a mating cable (see page 178).
_More information online at_ bannerengineering.com
101
TWO-HAND CONTROL MODULES
OTB Buttons
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS |
## **OTB Specifications**
|**Supply Voltage and Current**|**OTBVR81 models:**20 to 30V ac/dc<br>**OTBA5 models:**105 to 130V ac, 50-60 Hz<br>**OTBB5 models:**210 to 250V ac, 50-60 Hz<br>**OTBVN6/VP6 models:**10 to 30V dc<br>All models require less than 25 mA (exclusive of load)|
|---|---|
|**Supply Protection Circuitry**|Protected against reverse polarity and transient voltages|
|**Output Configuration**|**OTBVR81, OTBA5, and OTBB5 models:**SPDT electromechanical relay<br>**OTBVN6 models:**Complementary (SPDT) NPN (sinking) open-collector transistor; 1 normally open (NO) and 1<br>normally closed (NC)<br>**OTBVP6 models:**Complementary (SPDT) PNP (sourcing) open-collector transistors; 1 normally open (NO) and<br>1 normally closed (NC)|
|**Output Rating**|**Models with electromechanical relay:**<br>**Max. switching current:**7 amps (resistive load), 1 HP maximum<br>**Min. load:**0.05 watts (dc), 0.05 VA (ac)<br>**Mechanical life of relay:**50,000,000 operations (minimum)<br>**Electrical life of relay:**100,000 operations (min.) at full resistive load<br>Transient suppression is recommended when switching inductive loads.<br>**Models with solid-state outputs:**<br>150 mA maximum load (each output)<br>**On-state saturation voltage:**less than 1 volt at signal levels; less than 1.5 volts at full load<br>**Off-state leakage current:**less than 1 microamp|
|**Response Time**|100 milliseconds|
|**Output Protection**|All models protected against false pulse on power-up.<br>Models with solid-state outputs have overload and short circuit protection.|
|**Indicators**|**Two red indicator LEDs:**One lights whenever power is applied; the other lights whenever the switch is<br>activated making the normally-open (NO) output conduct.|
|**Construction**|Totally encapsulated, non-metallic enclosure. Black polysulfone or red polycarbonate upper housing (see<br>Application Notes below); fiber-reinforced thermoplastic polyester base. Electronics fully epoxy-encapsulated.<br>Supplied with a field cover of polypropylene (TP).|
|**Environmental Rating**|Meets NEMA standards 1, 3, 4, 4X, 12 and 13; IEC IP66|
|**Connections**|PVC-jacketed 2 m or 9 m cables, or Mini-style quick-disconnect (QD) fitting are available. QD cables are<br>ordered separately. See page 178.|
|**Ambient Light Immunity**|120,000 lux (direct sunlight)|
|**EMI/RFI Immunity**|Immune to both single and mixed EMI and RFI noise sources|
|**Operating Conditions**|**Temperature:**-20° to +50° C<br>**Relative humidity:**90% at 50° C (non-condensing)|
|**Application Notes**|**OTB Optical Touch Buttons by themselves are not stand alone devices.**They must be installed to prevent<br>accidental actuation (example, use of field covers). The environment in which they are installed must not<br>adversely affect the means of actuation (example, severe contamination). See DUO-TOUCH module manuals for<br>information on two-hand control safety applications.<br>**Environmental considerations for models with polysulfone upper housings:**<br>The polysulfone upper housing will become embrittled with prolonged exposure to outdoor sunlight. Window<br>glass effectively filters longer wavelength ultraviolet light and provides excellent protection from sunlight.<br>**Environmental considerations for models with polycarbonate upper housings:**<br>Avoid prolonged exposure to hot water and moist high-temperature environments above 66° C. Avoid contact<br>with aromatic hydrocarbons (such as xylene and toluene), halogenated hydrocarbons and strong alkalis.<br>Clean periodically using mild soap solution and a soft cloth. Avoid strong alkaline materials.|
|**Certifications**|For a list of certifications see page 236.|
|**Wiring Diagrams**|**Solid State NPN/PNP:**WD036 (p. 266)|
102 _More information online at_ bannerengineering.com
TWO-HAND CONTROL MODULES OTB Buttons
DUO-TOUCH® SG MODULES STB BUTTONS DUO-TOUCH® MODULES OTB BUTTONS
**==> picture [342 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|OTB Optical Touch Buttons Field Covers|DownloadPDF|
|Data|
|Models|Description|Sheet|
|OTC-1-BK|Black cover|
|OTC-1-GN|Green cover|
|28436|
|OTC-1-RD|Red cover|
|OTC-1-YW|Yellow cover|
**----- End of picture text -----**<br>
Field covers are designed to prevent inadvertent activation of optical touch buttons due to objects (loose clothing, debris, etc.) which might accidentally block their sensing beams. Field covers are constructed of rugged polypropylene and are highly resistant to abrasion and to damage by most chemicals. Standard model numbers are shipped with a black cover.
_More information online at_ bannerengineering.com
103
TWO-HAND CONTROL MODULES
104 _More information online at_ bannerengineering.com ~~tr~~
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →