AT 10 B10
Current Transducer, AC, AT Series, Split Core, 10A, 1.5 %, 10 Vdc Voltage Output
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Voltage; Supply Voltage DC Min:-; Supply Voltage DC Max:-; Current Measuring Range DC:-; Current Measuring Range AC:0A to 10A; Response Time:300ms; Accuracy %:1.5%; Product
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: 1.5%
- Accuracy %: 1.5%
- Product Range: AT Series
- Response Time: 300ms
- Primary Current: 0A to 10A
- Sensor Mounting: Cable
- Measured Current: AC
- Sensor Output Type: Voltage
- Supply Voltage Range: -
- Secondary Signal Type: Voltage
- Current Sensor Technology: Split-Core
- Operating Temperature Max: 60°C
- Operating Temperature Min: -20°C
- Current Measuring Range AC: 0A to 10A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 70.32 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **AC Current Transducer AT-B10** _I_ **= 5 ... 150 A** P N Split-core transducer for the electronic measurement of AC waveform currents, with galvanic separation between the primary circuit and the secondary circuit. 0-10 V DC switch voltage output proportional to the RMS value of the primary current. e ~~e~~ CEESUK FANRGHS° vsy ## **Features** ## ~~**Electrical data** Lo~~ - ●RMS (average) output - ●0-10 V DC voltage output - ●Split-core type |Primary nominal<br>Output voltage|Type|||| |---|---|---|---|---| |RMS current||||| |_I_P N(At RMS)<br>_U_out(V DC)||||| |5<br>0-10|AT 5 B10|||| |10<br>0-10<br>20<br>0-10|AT 10 B10<br>AT 20 B10|AT 10 B10<br>AT 20 B10||| |50<br>0-10<br>100<br>0-10<br>150<br>0-10|AT 50 B10<br>AT 100 B10<br>AT 150 B10|||| |_R_L<br>Load resistance||≥ 2||MΩ| |_U_C<br>Supply voltage<br>_U_S Z<br>Output clamping voltage||self-powered<br>15||V| |_Î_P<br>Overload capability<br>- continuous<br>120<br>% of_I_P N<br>- 1 min<br>150<br>% of_I_P N<br>~~**Performance data**~~<br>~~Lo~~||||| |_ε_<br>Error @_I_P N,_T_A= 25 °C (excluding offset)||< ±1.5|% of_I_P N|| |_ε_L<br>Linearity error||< ±0.5|% of_I_P N|| |_t_D 90<br>Delay time to 90 % of the final output value for|Delay time to 90 % of the final output value for_I_P Nstep ≤ 300|step ≤ 300||ms| |_BW_<br>Frequency bandwidth<br>50/60<br>Hz<br>~~**General data**~~<br>~~Lo~~||||| |_T_A<br>Ambient operating temperature||−20 … +60|−20 … +60|°C| |_T_A st<br>Ambient storage temperature||−20 … +85|−20 … +85|°C| |_RH_<br>Relative humidity (non-condensing)1)||_≤_85||%| |Altitude above sea level||2000||m| |||Indoor use only|Indoor use only|| |_m_<br>Mass||90||g| |IPxx<br>Protection degree||IP 40||| |Notes:<br>1)Long term exposure to high humidity environment may affect to product|||Long term exposure to high humidity environment may affect to product|| |reliability.||||| - ⌀ 16 mm sensing aperture for non-contact measurement - ●Terminal output - ●Insulating plastic case recognized according to UL 94-V0. ## **Advantages** - ●High insulation between primary and secondary circuits - ●Compact case - ●Cost-effective solution - ●Easy installation. ## **Applications** - **Automation and Supervision** Current measurement for process regulation by distributed PLCs or remote control (e.g. SCADA software) - **Safety and Condition Monitoring** Load monitoring for protection systems and predictive maintenance (e.g. conveyers, pumps or HVAC motors). ## **Application domains** - ●Energy - ●Automation. - Deviation of the output during test IEC 61000-4-3 @ 10 V/m - between 280 to 500 MHz. N° U2.05.08.200.0; U2.05.13.200.0; U2.05.17.200.0; U2.05.25.200.0; U2.05.34.200.0; U2.05.39.200.0 Page 1/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them. 9November2022/version 10 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com ## **Current Transducer AT-B10** ## ~~**Insulation coordination**~~ |_U_Nm|Rated insulation RMS voltage1), reinforced or||| |---|---|---|---| ||basic insulation|300|V| ||with IEC 61010-1 standards and following conditions:||| ||- Reinforced insulation||| ||- Over voltage category CAT III||| ||- Pollution degree PD2||| ||- Heterogeneous field||| |_U_d|RMS voltage for AC insulation test2), 50 Hz, 1 min|3.5|kV| |||Min|| |_d_Cp|Creepage distance|6|mm| |_d_CI|Clearance|6|mm| |_CTI_|Comparative tracking index (group I)|600|| Notes:[1)] If insulated cable is used for the primary circuit, the voltage category could be improved according to the insulation coordination given by the cable manufacturer 2) Between primary (completely filling the hole) and secondary. Page 2/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them. 9November2022/version 10 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com ## ~~**Safety and warning notes**~~ In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under www.lem.com. ## **Caution! Risk of danger** Ignoring the warnings can lead to serious injury and/or cause damage! The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training. The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturer’ operating instructions. ## **Caution, Risk of electrical shock** When operating the transducer, certain parts of the module may carry hazardous live voltage (eg. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a build-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. The transducer shall not be put into operation if the jaw opening is open (split core version) or the installation is not completed. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed. Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care. Page 3/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them. 9November2022/version 10 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com ## **Dimensions AT-B10** (in mm) **==> picture [444 x 266] intentionally omitted <==** **----- Start of picture text -----**<br> 16<br>O _ o<br>23.5<br>4 28.5 4<br>31.5<br>51 16<br>. 7 H E E<br>| 4 To l<br>2-M3 terminal with cover<br>N.P<br>18<br>18<br>1.5<br>(+)<br>22 40.5<br>(-)<br>2.5<br>+<br>+<br>L K<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** ## **Remark** - ●General tolerance - ●Primary aperture - ●Fastening ±1 mm - ⌀ 16 mm Cable tie - ●Attention: contact areas (air gap) must be kept clean (particle free) to ensure proper performance. ## **Connections** - ●Wires up to 2 mm ⌀ **==> picture [347 x 155] intentionally omitted <==** **----- Start of picture text -----**<br> (-) (+)<br>K<br>2 Measure +<br>2 I P bie [|] | 1 Measure -<br>(-) (+)<br>SF<br>Load<br>L<br>(Controller, meter etc)<br>**----- End of picture text -----**<br> LEM reserves the right to carry out modifications on its transducers, in order to improve them. Page 4/4 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com 9November2022/version 10
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →