Image not available
Illustrative purposes only
APC-8E-700
LED Driver, LED Lighting, 7.7 W, 11 VDC, 700 mA, Constant Current, 180 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (12-Jan-2017)
- Product Range: APC-8E
- Output Current: 700mA
- LED Driver Mode: Constant Current
- Output Power Max: 7.7W
- Input Voltage Max: 264V
- Input Voltage Min: 180V
- Output Voltage Max: 11VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 5.96 € |
| Current stock | 10+ |
| Lead time | 30 days |
> 8W Single Output Switching Power Supply **APC - 8E series** ~~$$$ ____~~ ## ■ **** - ‧ - ‧Ⅱ - ‧ - ‧ ## ** IP42** 7 ~~9enu~~ FAL ■ **** - ‧ - - - - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ ## ■ **** ■ **** ** ** | [L _File Name: APC-8E-SPEC 2020-09-25_ **APC - 8E series** 8W Single Output Switching Power Supply ## **SPECIFICATION** |**MODEL**<br>**APC-8E-350**<br>**APC-8E-700**<br>**OPERATING VOLTAGE RANGENote.4**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**SETUP, RISE TIME**<br>**VOLTAGE RANGENote.3**<br>**FREQUENCY RANGE**<br>**EFFICIENCY(Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**SHORT CIRCUIT**<br>11~23V<br>6~11V<br>350mA<br>700mA<br>8.05W<br>7.7W<br>300mVp-p<br>250mVp-p<br>500ms, 180ms / 230VAC<br>47 ~ 63Hz<br>80.5%<br>77.5%<br>0.15A/230VAC<br>0.25mA / 240VAC<br>-30 ~ 70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.2%/℃(0 ~45℃)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>℃<br><br><br><br><br><br>℃℃<br><br><br>※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>**RIPPLE & NOISE(max.) Note.2**<br>**NO LOAD OUTPUT VOLTAGE(max.)**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC<br>**EMC IMMUNITY**<br>Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020<br>Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020<br>**EMC EMISSION**<br>**HOLD UP TIME (Typ.)**<br>20ms/230VAC at full load<br>Hiccup mode, recovers automatically after fault condition is removed.<br>60*30*23.5(L*W*H)<br>COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VAC<br>μ<br>2275.8K hrs min. MIL-HDBK-217F (25℃)<br>I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH<br>180 ~ 264VAC 254 ~ 370VDC**(Note.5)**<br>**CURRENT ACCURACY**<br>±8.0%<br>**APC-8E-500**<br>8~16V<br>500mA<br>8W<br>300mVp-p<br>79%<br>**APC-8E-250**<br>16~32V<br>250mA<br>8W<br>350mVp-p<br>81.5%<br>29V<br>17V<br>24V<br>38V<br>**POWER FACTOR (Typ.)**<br>PF>0.5/230VAC at full load<br>ENEC EN61347-1,EN61347-2-13,EN62384,EAC TP TC 004 approved;<br>design refer to UL8750,CSA C22.2 No.250.0-08; EN60950-1<br>0.05Kg; 144pcs/7.6Kg/0.70CUFT|**MODEL**<br>**APC-8E-350**<br>**APC-8E-700**<br>**OPERATING VOLTAGE RANGENote.4**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**SETUP, RISE TIME**<br>**VOLTAGE RANGENote.3**<br>**FREQUENCY RANGE**<br>**EFFICIENCY(Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**SHORT CIRCUIT**<br>11~23V<br>6~11V<br>350mA<br>700mA<br>8.05W<br>7.7W<br>300mVp-p<br>250mVp-p<br>500ms, 180ms / 230VAC<br>47 ~ 63Hz<br>80.5%<br>77.5%<br>0.15A/230VAC<br>0.25mA / 240VAC<br>-30 ~ 70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.2%/℃(0 ~45℃)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>℃<br><br><br><br><br><br>℃℃<br><br><br>※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>**RIPPLE & NOISE(max.) Note.2**<br>**NO LOAD OUTPUT VOLTAGE(max.)**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC<br>**EMC IMMUNITY**<br>Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020<br>Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020<br>**EMC EMISSION**<br>**HOLD UP TIME (Typ.)**<br>20ms/230VAC at full load<br>Hiccup mode, recovers automatically after fault condition is removed.<br>60*30*23.5(L*W*H)<br>COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VAC<br>μ<br>2275.8K hrs min. MIL-HDBK-217F (25℃)<br>I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH<br>180 ~ 264VAC 254 ~ 370VDC**(Note.5)**<br>**CURRENT ACCURACY**<br>±8.0%<br>**APC-8E-500**<br>8~16V<br>500mA<br>8W<br>300mVp-p<br>79%<br>**APC-8E-250**<br>16~32V<br>250mA<br>8W<br>350mVp-p<br>81.5%<br>29V<br>17V<br>24V<br>38V<br>**POWER FACTOR (Typ.)**<br>PF>0.5/230VAC at full load<br>ENEC EN61347-1,EN61347-2-13,EN62384,EAC TP TC 004 approved;<br>design refer to UL8750,CSA C22.2 No.250.0-08; EN60950-1<br>0.05Kg; 144pcs/7.6Kg/0.70CUFT|**APC-8E-250**|**APC-8E-350**|**APC-8E-500**|**APC-8E-700**| |---|---|---|---|---|---| ||**RATED CURRENT**|250mA|350mA|500mA|700mA| ||**OPERATING VOLTAGE RANGENote.4**|16~32V|11~23V|8~16V|6~11V| ||**RATED POWER**|8W|8.05W|8W|7.7W| ||**RIPPLE & NOISE(max.) Note.2**|350mVp-p|300mVp-p|300mVp-p|250mVp-p| ||**NO LOAD OUTPUT VOLTAGE(max.)**|38V|29V|24V|17V| ||**CURRENT ACCURACY**|±8.0%|||| ||**SETUP, RISE TIME**|500ms, 180ms / 230VAC|||| ||**HOLD UP TIME (Typ.)**|20ms/230VAC at full load|||| ||**VOLTAGE RANGENote.3**|180 ~ 264VAC 254 ~ 370VDC**(Note.5)**|||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||| ||**POWER FACTOR (Typ.)**|PF>0.5/230VAC at full load|||| ||**EFFICIENCY(Typ.)**|81.5%|80.5%|79%|77.5%| ||**AC CURRENT**|0.15A/230VAC|||| ||**INRUSH CURRENT(Typ.)**|COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VAC<br>μ|||| ||**LEAKAGE CURRENT**|0.25mA / 240VAC|||| ||**SHORT CIRCUIT**|Hiccup mode, recovers automatically after fault condition is removed.|||| ||**WORKING TEMP.**|-30 ~ 70℃(Refer to "Derating Curve")|||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH|||| ||**TEMP. COEFFICIENT**|±0.2%/℃(0 ~45℃)|||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes|||| ||**SAFETY STANDARDS**|ENEC EN61347-1,EN61347-2-13,EN62384,EAC TP TC 004 approved;<br>design refer to UL8750,CSA C22.2 No.250.0-08; EN60950-1|||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC|||| ||**ISOLATION RESISTANCE**|I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH|||| ||**EMC EMISSION**|Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020|||| ||**EMC IMMUNITY**|Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020|||| ||**MTBF**|2275.8K hrs min. MIL-HDBK-217F (25℃)|||| ||**DIMENSION**|60*30*23.5(L*W*H)|||| ||**PACKING**|0.05Kg; 144pcs/7.6Kg/0.70CUFT|||| ||℃<br><br><br><br><br><br>℃℃<br><br><br>※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx||||| _File Name: APC-8E-SPEC 2020-09-25_ **APC - 8E series** ## 8W Single Output Switching Power Supply **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Unit:mm<br>73.1<br>65.5<br>60 150±10<br>+V(Red)<br>IEC52 H03VVH2-F 0.75mm2 tc -V(Black)<br>AC/N(Blue) 35 UL1569 20AWG<br>AC/L(Brown)<br>150±10<br>‧ : Max. Case Temperaturetc<br>Block Diagram<br>fosc : 67KHz<br>POWER RECTIFIERS +V<br>I/P EMI FILTER RECTIFIERS SWITCHING & -V<br>FILTER<br>PWM<br>CONTROL<br>Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>80<br>60 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-30 0 10 20 30 40 45 50 60 70 (HORIZONTAL) 180 190 200 210 220 230 240 250 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>12.5<br>30 8.5<br>23.5<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name: APC-8E-SPEC 2020-09-25_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →