- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Voltage; Supply Voltage DC Min:-; Supply Voltage DC Max:-; Current Measuring Range DC:-; Current Measuring Range AC:-; Response Time:-; Accuracy %:1%; Product Range:-;
- SVHC: No SVHC (25-Jun-2025)
- Accuracy %: 1%
- Product Range: AP Series
- Sensor Output Type: Voltage
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 126.96 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **AC Current transducer AP-B10** ## **I = 10 .. 400 A PN** Split-core transducer for the electronic measurement AC sinusoidal waveform currents, with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronics). Switch selectable measuring ranges and RMS 0-5V and 0-10V switch selectable voltage output. ## **Electrical data** |**Electrical data**|**Electrical data**|||| |---|---|---|---|---| |Primary Nominal Current<br>Output Voltage (Analog)||Type||RoHS since| |IPN(A.t.rms)<br>VOUT(V DC)||||date code| |10,25,50<br>0-5 or 0-10||**AP 50 B10**||46320| |50,75,100<br>0-5 or 0-10||**AP 100 B10**||46333| |100,150,200<br>0-5 or 0-10||**AP 200 B10**||47282| |200,300,400<br>0-5 or 0-10||**AP 400 B10**||planned| |**R **L|Load resistance||≥10|kΩ| |**V**C|Supply voltage||+ 24 ± 5%V DC|+ 24 ± 5%V DC| |**I**C|Current Consumption||< 30|mA| |**V**SL|Output voltage limitation (0-10V)||14|V| |**V**SL|Output voltage limitation (0-5V)||7|V| |**Î**P|Overload capability||no limitation|| |**Accuracy-Dynamic performance data**||||| |**X**|Accuracy @**I**PN,**T**A= 25°C (excluding offset)||< ± 1|% of**I**PN| |**ε**L|Linearity error (0 .. ±**I**PN)||< ± 0.5 % of**I**PN|| |**V**OE|Electrical offset voltage @**T**A= 25°C||< ± 0.5 % of**I**PN|| |**TCV**OE|Temperature coefficient of**V**OE||± 1|mV/K| |**TCV**OUT|Temperature coefficient of**V**OUT(% of reading)||± 0.1|%/K| |**t **r|Response time to 90% of**I**PNstep||< 150<br>m s|| |**BW**|Frequency bandwidth (± 1 %)||30 .. 2000|30 .. 2000<br>Hz| |**General data**||||| |**T**A|Ambient operating temperature||- 20 .. + 60<br>°C|| |**T**S|Ambient storage temperature||- 20 .. + 85<br>°C|| |**_m_**|Mass||90|g| |**IPxx**|Protection degree||IP20|| ## **Features** - RMS output (average) - Split-core type - 0-5 VDC and 0-10 VDC switch selectable voltage output - DIN rail or Panel mounting - Switch selectable measuring ranges - Isolated plastic case recognized according to UL94-V0. ## **Advantages** - Large aperture for cable up to Ø18mm - High isolation between primary and secondary circuits - Eliminates insertion loss - Easy installation ## **Applications** - _**Automation systems**_ Analog current reading for remote monitoring (e.g. motor) and software alarms. - _**Panel meters**_ Simple connection to power consumption displays. ## **Application domain** - Energy and Automation Page 1/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 080212/5 www.lem.com ## **Current Transducer AP-B10** ## **Isolation characteristics** |**V**b|Rated isolation voltage rms1)|300|V| |---|---|---|---| ||with IEC 61010-1 standards and following conditions :||| ||- Reinforced isolation||| ||- Over voltage category CAT III||| ||- Pollution degree PD2||| ||- Heterogeneous field||| |**V**d|Rms voltage for AC isolation test2), 50 Hz, 1min|5|kV| |**V**e|Partial discharge extinction voltage rms @ 10 pC|1.5|kV| |**V**w|Impulse withstand voltage 1.2/50µs|6.1|kV| |**dCp**|Creepage distance|5.5|m m| |**dCl**|Clearance distance|5.5|m m| |**CTI**|Comparative tracking index (Group I)|600|| Notes :[1)] If insulated cable is used for the primary circuit, the voltage category could be improved according to the insulation characteristics given by the cable manufacturer. |manufacturer.|| |---|---| |e.g.|| |Cable insulation (primary)|Category| |HAR 05|600V CAT III| |HAR 07|1000V CAT III| - 2) Between primary (completely filling the aperture) and secondary. Page 2/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 080212/5 www.lem.com ## **Current Transducer AP-B10** ## LC **Safety and warning notes** In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under www.lem.com. ## **Caution! Risk of danger** Ignoring the warnings can lead to serious injury and/or cause damage! The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training. The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturers’ operating instructions. ## **Caution! Risk of electrical shock** When operating the transducer, certain parts of the module may carry hazardous live voltage (e.g. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a built-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. The transducer shall not be put into operation if the jaw opening is open (split core version) or the installation is not completed. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed. Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care. Page 3/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 080212/5 www.lem.com ## **Dimensions AP(R)-B10** (unit : mm, 1mm = 0.0394 inch) **==> picture [427 x 350] intentionally omitted <==** **----- Start of picture text -----**<br> Output Voltage Front View Left View<br>Selection Switch<br>55<br>16.40<br>20<br>Range Selection Switch<br>.<br>Wty 40(distance between screws) a rel<br>37<br>YY al |<br>Axis of aperture 25<br>67<br>Plug-in connector included : XW4B-03C1-H1 (OMRON)<br>18.50<br>Bottom View<br>4.70<br>14.80<br>69<br>DIN size 35.50<br>33.50<br>21<br>18.50<br>**----- End of picture text -----**<br> ## **0-5, 10V Selectable** **==> picture [182 x 117] intentionally omitted <==** **----- Start of picture text -----**<br> GND<br>RL<br>OUTPUT<br>AP/APR<br>+24VDC<br>Output<br>Connector<br>3(-) 2(out)1(+)<br>Output Switch Range Switch<br>v Front<br>**----- End of picture text -----**<br> **==> picture [34 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> +24VDC<br>Is<br>OUT<br>GND<br>**----- End of picture text -----**<br> **==> picture [6 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Ip<br>**----- End of picture text -----**<br> ## **Connections** - Wires up to ∅ 2 mm - Female connector provided (spring terminal blocks) - User-friendly spring-cage connection for no-tool direct conductor connection ## **Mechanical characteristics** - General tolerance ± 1 mm - • Primary aperture ∅ 18.5 mm • Panel mounting 2 holes ∅ 4.0 mm • Distance between holes 40.0 mm For panel mounting, replace M4 screws by new one (not supplied) with appropriate length to panel´s thickness. Page 4/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 080212/5 www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →