AKW91110
Panel Meter, 85 VAC to 264 VAC, 50/60 Hz, Panel Mount, KW9M Series
- Manufacturer: PANASONIC
- Product type: Digital Panel Meters
- Available until stocks are exhausted
- SVHC: To Be Advised
- Meter Range: -99999kW to 99999kW, 0kWh to 9999999.9kWh, 0kA to 99.999kA, 0kV to 99.999kV, 0Hz to 99.99Hz
- Digit Height: -
- Product Range: KW9M Series
- Meter Function: Current, Voltage, Frequency, Power, Energy, Temperature
- Panel Cutout Width: 92mm
- Supply Voltage Max: 264VAC
- Supply Voltage Min: 85VAC
- Panel Cutout Height: 92mm
- No. of Digits / Alpha: -
- Operating Temperature Max: 55°C
- Operating Temperature Min: -25°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 377.31 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- ECO POWER METER** KW9M ## Multi function type developed by adding a power surveillance function to a simple power meter ## A lication exam les pp p **==> picture [381 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> Office area<br>Distribution board<br>Motor pump, FP WEB-SERVER<br>(for lighting system) Lights blower and with expansion<br>fan heater<br>KW Watcher<br>Excel<br>KW9M KW9M RS485 LAN<br>Browser<br>Factory area For details of products other<br>than KW9M , please refer to<br>Distribution board Production FP WEB-SERVER the individual catalogs.<br>**----- End of picture text -----**<br> **==> picture [227 x 94] intentionally omitted <==** **----- Start of picture text -----**<br> Factory area<br>Distribution board Production FP WEB-SERVER<br>(for power system) [Control panel] Motor equipment with expansion<br>KW9M KW9M RS485 KW9M<br>**----- End of picture text -----**<br> **==> picture [34 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Smartphone<br>**----- End of picture text -----**<br> ## **Energy harvesting** **==> picture [102 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Solar tracker Wind farm<br>**----- End of picture text -----**<br> **FP WEB-SERVER with expansion** **KW9M KW9M KW9M** ## S pecifications ## **Order guide** |Product name<br>KW9M Eco-POWER METER<br>Standard type|Phase and wire system<br>1-phase, 2-wire system<br>1-phase, 3-wire system<br>3-phase, 3-wire system<br>3-phase, 4-wire system|Measurement voltage<br>0 to 500V AC|Measurement current 1)<br>1 to 4000A|Part no.<br>**AKW91110**| |---|---|---|---|---| > 1) Please contact our sales offices for current transformers (CT) with a secondary current of 1A or 5A. ## **Measurement input specifications** ## **Measurement items** |Item<br>Unit<br>Data display range<br>Item<br>Description|| |---|---| |Electric energy<br>(import)<br>Active<br>kWh<br>0.000 to 9999999.9<br>Reactive<br>kvarh<br>Apparent<br>kVAh<br>Electric energy<br>(export)<br>Active<br>kWh<br>0.000 to 9999999.9<br>Reactive<br>kvarh<br>Instantaneous<br>electric power<br>Active<br>kW<br>–99999 to 0.000 to 99999<br>Reactive<br>kvar<br>Apparent<br>kVA<br>Current<br>A<br>0.000 to 8000.0<br>Voltage<br>V<br>0.00 to 99999<br>Power factor<br>–1.000 to 0.000 to 1.000<br>Frequency<br>Hz<br>0.00 to 99.99<br>Conversion value<br>0.000 to 9999999.9<br>Temperature<br>°C<br>–100.0 to 0.0 to 100.0<br>Voltage<br>Input voltage<br>1P2W<br>L-L<br>0 to 500VAC<br>1P3W<br>L-L<br>0 to 500VAC<br>L-N<br>0 to 250VAC<br>3P3W<br>L-L<br>0 to 500VAC<br>3P4W<br>L-L<br>0 to 500VAC<br>L-N<br>0 to 289VAC<br>Impedance<br>2MΩ or more(L-N;V1/V2/V3-Vn)<br>Resolution<br>0.01V<br>Accuracy1)<br>0.5%<br>VT ratio<br>1.00 to 600.00 (set with setting mode)<br>Voltage transformer (VT) is required when you measure a load<br>with voltage over rated voltage.<br>Current<br>Input current<br>(with CT)<br>Primarycurrent<br>4000A or less<br>Secondary current<br>1A or 5A<br>Max. current<br>10A(200% of input current)<br>Overload<br>capacity<br>1000% of input current for 3s<br>Resolution<br>0.001A<br>~~So~~<br>~~es~~<br>~~-—}—J~~<br>~~|~~<br>~~||~~<br>~~a~~<br>~~-—~~<br>~~ee ee~~<br>~~|~~<br>~~ee ee~~<br>~~||~~<br>~~—~~<br>~~|~~<br>~~Po~~<br>~~|~~<br>~~|I~~|| |Accuracy1)<br>0.5%|| |**General unit specifications**<br>Power<br>Accuracy1)<br>1.0%<br>Activepower class 1(IEC 62053-21)<br>Reactivepower class 2(IEC 62053-23)<br>~~_~~|| |Item<br>Description<br>Temper-<br>ature<br>Accuracy<br>±5.0°C|| ## **General unit specifications** |Item<br>Rated operating<br>voltage<br>AC<br>DC<br>~~| |~~<br>~~|~~|Item<br>Rated operating<br>voltage<br>AC<br>DC<br>~~| |~~<br>~~|~~|Description<br>85 to 264V|Description<br>85 to 264V| |---|---|---|---| ||DC<br>~~| |~~<br>~~|~~|100 to 300V|| |Rated frequency||50/60Hz|| |Rated power consumption||5VA approx.(240V AC at 25°C)|| |||3W approx.(240V DC at 25°C)|| |Momentary power-off time||10ms|| |Ambient temperature||Accuracy guarantee: –10 to +55°C|| |||Operation: –25 to +55°C|| |||Storage: –25 to +70°C<br>~~ne~~|| |Ambient humidity||30 to 85% RH (at 20°C) non-condensing<br>~~ne~~|| |Display method||LCD with backlight<br>~~ne~~|| |Measurement speed||Sampling rate<br>~~ne~~|1.024 MHz (1.0µs approx.)| |||Data update time<br>~~ne~~|100ms| |Power failure memory||Internal memory (overwrite 1010or more)<br>Saved data: setting and measurement values<br>~~ne~~|| |Dimensions W/H/D||Saved data: setting and measurement values<br>96 x 96 x 56mm (without terminal block)<br>96 x 96 x 68mm (with terminal block)|| |Weight||96 x 96 x 68mm (with terminal block)<br>450g approx.|| - 1) Errors resulting from current transformers (CT) and voltage transformers (VT) are not considered. ## **Communication** |Item<br>Protocol|RS485<br>MEWTOCOL/Modbus<br>(RTU) (selectable)<br>~~a~~|USB (Full Speed)<br>MEWTOCOL<br>~~a~~| |---|---|---| |Max. number of<br>stations|(RTU) (selectable)<br>99<br>~~a~~|1<br>~~a~~| |Transmission speed|38400/19200/9600/4800/2400/1200bit/s<br>~~a~~|| **Dimensions** [mm] **==> picture [13 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> □ 96<br>**----- End of picture text -----**<br> **==> picture [148 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> LCD SET key ITEM / Increase key<br>MODE key SHIFT / Decrease key<br>**----- End of picture text -----**<br> **==> picture [281 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> 68<br>14 56 Terminal block<br>Terminal<br>block A aa!| 7<br>Mounting Terminal block B<br>clip<br>Mounting screw: M4×10<br>91 ±0.4<br>□ 70.4 70.4<br>25.6 25.6<br>**----- End of picture text -----**<br> ## Panel cut-out ## Panel mounting 1) Remove the mounting clips from the unit. - 2) Insert the unit from the front of the panel. - 3) Attach the mounting clips at the both side of the case and secure in place with the screws. • Applicable panel thickness: 1 to 5mm 92 ±0.5 When mounting several units adjacent to each ~~——~~ other, keep at least 130mm of space on all sides measured from the center of the unit. **==> picture [32 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Conforming to<br>EMC Directive<br>**----- End of picture text -----**<br> ## **Terminal arrangement and wiring diagrams** **==> picture [479 x 294] intentionally omitted <==** **----- Start of picture text -----**<br> Rear view Wiring diagrams<br>Terminal 1-phase, 2-wire Terminal block A (upper) Terminal block B (lower)<br>block A system<br>(10) 1 2 3 4 5 6 1 2 3 4 5 6<br>k l k l k l<br>Breaker X X To measure<br>( )3 circuits<br>Terminal block B AUX X X<br>(8) (Power supply)<br>CT1 CT2 CT3<br>L1 (R)<br>USB port<br>(To measure 3 circuits)<br>N<br>K L<br>1-phase, 3-wire<br>system Terminal block A (upper) Terminal block B (lower)<br>Terminal arrangement 3-phase, 3-wire system 1 2 3 4 5 6 1 2 3 4 5 6<br>Terminal block A (upper) 10P k l k l<br>Terminal Breaker X X X X X<br>number 1 2 3 4 5 6 7 8 9 10<br>AUX<br>L+ N- V1 V2 V3 Vn NC SG A+ B- (Power supply)<br>CT1<br>Functions AUX L1 (R)<br>(Power supply) [Voltage measurement input] RS485 L2 (N/S)<br>CT2<br>L3 (T)<br>K L<br>Terminal block B (lower) 8P<br>3-phase, 4-wire Terminal block A (upper) Terminal block B (lower)<br>Terminal number 1 2 3 4 5 6 7 8 system 1 2 3 4 5 6 1 2 3 4 5 6<br>*CT1k *CT1l *CT2k *CT2l *CT3k *CT3l NC NC Breaker X X X X X X k l k l k l<br>Functions<br>Current measurement input AUX<br>(Power supply)<br>CT1<br>*CT = current transformer L1 (R)<br>L2 (S) CT2<br>CT3<br>L3 (T)<br>appar N i<br>K L<br>Power Load side<br>supply side<br>Power Load side<br>supply side<br>Power Load side<br>supply side<br>**----- End of picture text -----**<br> ## Features ## **Feature 1** - Large-screen LCD with backlight clearly displays values in four lines - High accuracy! Instantaneous active power: 1%, class 1 (IEC62053-21) Display updating time: 0.1s ## **Feature 4** - Capable of displaying currents as low as 1mA - This allows standby power consumption to be monitored, which helps save energy **==> picture [56 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> As low as 1mA<br>can be displayed<br>**----- End of picture text -----**<br> **==> picture [207 x 81] intentionally omitted <==** **----- Start of picture text -----**<br> Large key switches for<br>easy operation<br>96mm UU<br>= i 30000igb6<br>96mm<br>**----- End of picture text -----**<br> ## **Feature 2** - The total and individual power values of each phase are displayed on one screen, enabling you to check the phase balance at a glance. The data is useful for power quality checks and power factor improvements. ## **Feature 5** - Regenerative power can also be measured by one KW9M Eco-POWER METER. Bidirectional integrated electric power of each circuit can be measured. - Capable of displaying voltages, currents, electric power (active, reactive, apparent) and power factor **==> picture [200 x 177] intentionally omitted <==** **----- Start of picture text -----**<br> Phase 1Phase 2 Active powerDEMANDLEADMAXLAGMIN Pee Reactive powerDEMANDLEADMAXLAGMIN G o Apparent powerDEMANDLEADMAXLAGMIN 5<br>Phase 3<br>Total von + “FRB * “Whoa *<br>vom Phase 1 30000 Phase 2 > 3908 Phase 3 ><br>ActiveReactive DEMANDLEADMAXLAGMIN DEMANDLEADMAXLAGMIN DEMANDLEADMAXLAGMIN<br>Apparent sessed “ annWILLS ka “ annULILILI wa “<br>Current Voltage (phase) Voltage (line)<br>T iat wt<br>DEMANDLEADMAXLAGMIN * “16008 DEMANDLEADMAXLAGMIN * “hone DEMANDLEADMAXLAGMIN »<br>> ehog * enge| || ~<br>Average<br>**----- End of picture text -----**<br> ## **Feature 3** EEE - Panel-mount type capable of multi-circuit measurement - Capable of simultaneously measuring up to three circuits in a single phase, two-wire system of same power supply **==> picture [123 x 56] intentionally omitted <==** **----- Start of picture text -----**<br> Export<br>Import<br>J ===5><br>Feature 6<br>**----- End of picture text -----**<br> - Measuring power using large-capacity general-purpose CT (secondary side current 1A/5A) **==> picture [210 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> Breaker<br>ON<br>Power supply<br>K Secondary current ! K =<br>Le CT with 2nd current ) om<br>ata1 ° 1A/5A 1 e ” No CT s* ‘tod<br>L L<br>i ni t required | Soee<br>1 7 See? i KW9M<br>coos |<br>Production equipment<br>**----- End of picture text -----**<br> ## **Feature 7** **==> picture [452 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> Q y • Compatible with AC/DC power supply<br>Switch box<br>a H etoo'!ooiy 1g AC <=<br>supplyPower 12 *CT1 Load 1 DC O<br>1<br>*CT2 Load 2 Relay<br>ec OY 1 Storage Sana1 Bee<br>battery<br>*CT3 Load 3<br>_* tant *CT = ms, I current transformer an J | : i Ai le<br>**----- End of picture text -----**<br> **==> picture [151 x 22] intentionally omitted <==** **----- Start of picture text -----**<br> North America Europe<br>Lo<br>**----- End of picture text -----**<br> **==> picture [254 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> Asia Pacific China Japan<br>**----- End of picture text -----**<br> ## **Panasonic Electric Works** ## **Please contact our Global Sales Companies in:** - **Europe** - ▸ **Headquarters Panasonic Electric Works Europe AG** Rudolf-Diesel-Ring 2, 83607 Holzkirchen, Tel. +49 (0) 8024 648-0, Fax +49 (0) 8024 648-111, www.panasonic-electric-works.com ▸ **Austria Panasonic Electric Works Austria GmbH** Josef Madersperger Str. 2, 2362 Biedermannsdorf, Tel. +43 (0) 2236-26846, Fax +43 (0) 2236-46133 www.panasonic-electric-works.at - **Panasonic Industrial Devices Materials** Ennshafenstraße 30, 4470 Enns, Tel. +43 (0) 7223 883, Fax +43 (0) 7223 88333, www.panasonic-electronic-materials.com **Europe GmbH** - ▸ **Benelux Panasonic Electric Works** De Rijn 4, (Postbus 211), 5684 PJ Best, (5680 AE Best), Netherlands, Tel. +31 (0) 499 372727, Fax +31 (0) 499 372185, **Sales Western Europe B.V.** www.panasonic-electric-works.nl - ▸ **Czech Republic Panasonic Electric Works Europe AG** Administrative centre PLATINIUM, Veveri 111, 616 00 Brno, Tel. +420 541 217 001, Fax +420 541 217 101, www.panasonic-electric-works.cz - ▸ **France Panasonic Electric Works** Succursale française, 10, rue des petits ruisseaux, 91370 Verrières Le Buisson, Tél. +33 (0) 1 6013 5757, Fax +33 (0) 1 6013 5758, **Sales Western Europe B.V.** www.panasonic-electric-works.fr - ▸ **Germany Panasonic Electric Works Europe AG** Rudolf-Diesel-Ring 2, 83607 Holzkirchen, Tel. +49 (0) 8024 648-0, Fax +49 (0) 8024 648-111, www.panasonic-electric-works.de ▸ **Hungary Panasonic Electric Works Europe AG** Magyarországi Közvetlen Kereskedelmi Képviselet, 1117 Budapest, Neumann János u. 1., Tel. +36 1 999 89 26 www.panasonic-electric-works.hu - ▸ **Ireland Panasonic Electric Works UK Ltd.** Irish Branch Offi ce, Dublin, Tel. +353 (0) 14600969, Fax +353 (0) 14601131, www.panasonic-electric-works.co.uk ▸ **Italy Panasonic Electric Works Italia srl** Via del Commercio 3-5 (Z.I. Ferlina), 37012 Bussolengo (VR), Tel. +39 0456752711, Fax +39 0456700444, www.panasonic-electric-works.it - ▸ **Nordic Countries Panasonic Electric Works Europe AG** Filial Nordic, Knarrarnäsgatan 15, 164 40 Kista, Sweden, Tel. +46 859476680, Fax +46 859476690, www.panasonic-electric-works.se **Panasonic Eco Solutions Nordic AB** Jungmansgatan 12, 21119 Malmö, Tel. +46 40 697 7000, Fax +46 40 697 7099, www.panasonic-fi re-security.com - ▸ **Poland Panasonic Electric Works Polska sp. z o.o** ul. Wołoska 9A, 02-583 Warszawa, Tel. +48 22 338-11-33, Fax +48 22 338-12-00, www.panasonic-electric-works.pl ▸ **Portugal Panasonic Electric Works España S.A.** Portuguese Branch Offi ce, Avda Adelino Amaro da Costa 728 R/C J, 2750-277 Cascais, Tel. +351 214812520, Fax +351 214812529 ▸ **Spain Panasonic Electric Works España S.A.** Barajas Park, San Severo 20, 28042 Madrid, Tel. +34 913293875, Fax +34 913292976, www.panasonic-electric-works.es ▸ **Switzerland Panasonic Electric Works Schweiz AG** Grundstrasse 8, 6343 Rotkreuz, Tel. +41 (0) 41 7997050, Fax +41 (0) 41 7997055, www.panasonic-electric-works.ch ▸ **United Kingdom Panasonic Electric Works UK Ltd.** Sunrise Parkway, Linford Wood, Milton Keynes, MK14 6 LF, Tel. +44 (0) 1908 231555, Fax +44 (0) 1908 231599, www.panasonic-electric-works.co.uk **North & South America** ▸ **USA Panasonic Industrial Devices Sales Company** 629 Central Avenue, New Providence, N.J. 07974, Tel. 1-908-464-3550, Fax 1-908-464-8513, www.pewa.panasonic.com **of America Asia Pacifi c / China / Japan** ▸ **China Panasonic Electric Works Sales (China) Co. Ltd.** Level 2, Tower W3, The Towers Oriental Plaza, No. 2, East Chang An Ave., Dong Cheng District, Beijing 100738, Tel. +86-10-5925-5988, Fax +86-10-5925-5973 ▸ **Hong Kong Panasonic Industrial Devices Automation** RM1205-9, 12/F, Tower 2, The Gateway, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong, Tel. +852-2956-3118, Fax +852-2956-0398 **Controls Sales (Hong Kong) Co., Ltd.** ▸ **Japan Panasonic Corporation** 1048 Kadoma, Kadoma-shi, Osaka 571-8686, Japan, Tel. +81-6-6908-1050, Fax +81-6-6908-5781, www.panasonic.net ▸ **Singapore Panasonic Industrial Devices** 300 Beach Road, #16-01 The Concourse, Singapore 199555, Tel. +65-6390-3811, Fax +65-6390-3810 **Automation Controls Sales Asia Pacifi c** Copyright © 2013 • Printed in Germany 6216 euen 04/13
Updated at June 9, 2026
Panasonic Industry is a global leader in the design and manufacture of high-quality electronic components. Renowned for a commitment to continuous innovation, the company provides the essential building blocks that empower modern engineering. From industrial automation to consumer electronics, Panasonic's components are trusted worldwide for their outstanding reliability, efficiency, and long-term performance. The extensive portfolio is anchored by a massive selection of passive components, featuring an industry-leading range of aluminium electrolytic, film, and polymer capacitors. Alongside these advanced capacitance solutions, engineers rely on Panasonic's robust power inductors and a highly versatile array of electromechanical devices, including solid-state, power, and signal relays engineered to excel in demanding environments. Beyond core passives and switching solutions, the offering encompasses critical circuit protection devices such as TVS varistors and NTC thermistors, as well as sophisticated thermal management materials. Panasonic also delivers precision light and motion sensors, highly reliable batteries, and advanced Bluetooth and WLAN connectivity modules, providing a comprehensive ecosystem of components to support next-generation technological design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →