ADT-060A24AA B-A
AC/DC Power Supply, ITE, 1 Output, 60 W, 24 V, 2.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS
- Product type: AC / DC External Plug In Adaptor Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Plug Type: IEC 60320 C6
- Product Range: ADT-60 W Series
- No. of Outputs: 1 Output
- Output Connector: Tuning Fork 2.1mm x 5.5mm x 9.5mm
- Output Power Max: 60W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 14.36 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHINCAL DATASHEET** ## **AC-DC Adapter** ADT-60W Series / ADT-060A **□** A **□** B-A ## **ADT-060A** ## **Highlights & Features** - **Highlights & Features** Up to 89% efficiency Meet ErP Lot 7 & DoE VI No load power consumption < 0.15 W Over-Voltage/Load/Temperature & Short Circuit protections Limited Power Source (LPS) certified **Safety Standards** CE @ & [@ wer EE CB Certified for worldwide use **Model Number:** ADT-060A `☐` A `☐` B-A **Unit Weight:** 180±10 grams (6.35±0.35 ounces) **Dimensions (W x L x H):** 46.0 x 108.0 x 29.5 mm (1.81 x 4.25 x 1.16 inch) ## **General Description** The ADT-060A adapter comes with universal AC input at 85 Vac to 264 Vac. With the efficiency up to 89% and the extremely low noload power consumption below 0.15 W, the ADT-060A is compliant with DoE level VI and ErP Lot 7 efficiency standard for energy savings. The supreme feature allows the adapter to save the energy when it is either under the operating mode or under the standby mode. ## **Model Information** |**ModelNumber**|**Input Voltage Range**|**Rated OutputVoltage**|**Rated Output Current**| |---|---|---|---| |ADT-060A12A☐B-A|85-264 Vac|12 Vdc|5.0 A| |ADT-060A15A☐B-A||15 Vdc|4.0 A| |ADT-060A19A☐B-A||19 Vdc|3.2 A| |ADT-060A24A☐B-A||24 Vdc|2.5 A| ## **Model Numbering** |||||||**CC Code**|| |---|---|---|---|---|---|---|---| |**ADT-**|**060**|**A**|□|**A**|□|**B-**|**A**| |Delta AC-DC<br>Adapter|Output Power<br>(60W series)|Family<br>Code|Output Voltage<br>(Single Output)<br>12 – 12 V<br>15 – 15 V<br>19 – 19 V<br>24 – 24 V|Package Type<br>A – Power<br>Adapter|Input Connector<br>Type<br>A – C6 (Class II<br>with functional<br>earth)<br>B – C8|Tuning fork<br>5.5 x 2.1 x 9.5 mm,<br>180°|Delta<br>Standard| All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (July 2023, Rev. 05)** 1 **TECHINCAL DATASHEET** **AC-DC Adapter** ADT-60W Series / ADT-060A **□** A **□** B-A ## **Specifications** |Nominal Input Voltage|Nominal Input Voltage|100-240 Vac|100-240 Vac|100-240 Vac|100-240 Vac| |---|---|---|---|---|---| |Input Voltage Range*||85-264 Vac|||| |Nominal Input Frequency||50-60 Hz|||| |Input FrequencyRange||47-63 Hz|||| |Input Current|115 Vac 1.4 A max.|115 Vac 1.4 A max.|||| ||230 Vac|1.0 A max.|||| |Efficiency at 100%<br>Load|115 Vac 87.6% t|115 Vac 87.6% typ.|87.9% typ.|88.1% typ.|88.8% typ.| ||230 Vac 90.2% t|230 Vac 90.2% typ.|90.0% typ.|90.3% typ.|90.1% typ.| |Average Efficiency<br>(25%, 50%, 75%, 100%)||89% min. @ 115 Vac & 230 Vac|||| |Efficiency @ 10% load||79% @ 115 Vac & 230 Vac|||| |No Load Power Consumption||0.15 W max @ 115 Vac & 230 Vac|||| |Inrush Current||No damage|||| |Leakage Current(max.)||0.1 mA @ 240 Vac / 50 Hz|||| ## Input Ratings / Characteristics *Output power is de-rated at low input voltage. Please refer to Fig. 3 on page 7 **==> picture [513 x 347] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>95 95<br>90 90<br>85 85<br>115Vac Efficiency 115Vac Efficiency<br>80 80<br>75 230Vac Efficiency 75 230Vac Efficiency<br>70 70<br>65 65<br>60 60<br>55 55<br>50 a= 50<br>25 50 75 100 25 50 75 100<br>Output Load (%) Output Load (%)<br>Fig. 1-1. ADT-060A12A Efficiency versus Output Load Fig. 1-2. ADT-060A15A Efficiency versus Output Load<br>100 100<br>95 95<br>90 90<br>85 85<br>115Vac Efficiency 115Vac Efficiency<br>80 80<br>75 230Vac Efficiency 75 230Vac Efficiency<br>70 70<br>65 65<br>60 60<br>55 55<br>50 == 50<br>25 50 75 100 25 50 75 100<br>Output Load (%) Output Load (%)<br>Fig. 1-3. ADT-060A19A Efficiency versus Output Load Fig. 1-4. ADT-060A24A Efficiency versus Output Load<br>Efficiency (%) Efficiency (%)<br>Efficiency (%) Efficiency (%)<br>**----- End of picture text -----**<br> **Fig. 1-1. ADT-060A12A Efficiency versus Output Load** **Fig. 1-3. ADT-060A19A Efficiency versus Output Load** All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (July 2023, Rev. 05)** 2 **TECHINCAL DATASHEET** ## **AC-DC Adapter** ADT-60W Series / ADT-060A **□** A **□** B-A |Output Ratings / Characteristics|Output Ratings / Characteristics||||| |---|---|---|---|---|---| |Nominal Output Voltage||12 Vdc|15 Vdc|19 Vdc|24 Vdc| |Rated Output Current||5 A|4 A|3.2A|2.5 A| |Output Power||60 W|60 W|60.8 W|60 W| |Line Regulation||± 1%|||| |Load Regulation||± 5.0%|± 4.0%|± 3.0%|± 2.5%| |Combine Regulation||± 8.0%|± 7.0%|± 5.0%|± 5.0%| |PARD* (20MHz)|0°C to 40°C|< 240 mVpp|< 300 mVpp|< 380 mVpp|< 480 mVpp| ||-10°C to 0°C < 480 mV|-10°C to 0°C < 480 mVpp|< 600 mVpp|< 760 mVpp|< 960 mVpp| |Rise Time|115 Vac 30 mS (typ.)|115 Vac 30 mS (typ.)|||| ||230 Vac||||| |Start-up Time|115 Vac|1000 ms (typ.)|||| ||230 Vac|500 ms (typ.)|||| |Hold-up Time|115 Vac|12 ms (typ.)|||| ||230 Vac|60 ms (typ.)|||| |Capacitive load(max)||470 uF|||| ADT-060A12A `☐` B-A ADT-060A15A `☐` B-A ADT-060A19A `☐` B-A ADT-060A24A `☐` B-A ## Output Ratings / Characteristics *PARD is measured with an AC coupling mode, and in parallel with 0.1µF ceramic capacitor & 22µF electrolytic capacitor. ## Mechanical |Mechanical|Mechanical||| |---|---|---|---| |Case||PC|| |Dimensions (W x L x H)||46.0 x 108.0 x 29.5 mm (1.81 x 4.25 x 1.16 inch)|| |Unit Weight||180±10grams(6.35±0.35 ounces)|| |CoolingSystem||Convection|| |Output Cable<br>Specification|Length: 1200 mm<br>UL1571|#16AWG|ADT-060A12AA B / ADT-060A12AB B| |||#18AWG|ADT-060A15AA B / ADT-060A15AB B| |||#20AWG|ADT-060A19AA B / ADT-060A19AB B<br>ADT-060A24AA B / ADT-060A24AB B| |Input Socket||C6|ADT-060A12AA B<br>ADT-060A15AA B<br>ADT-060A19AA B<br>ADT-060A24AA B| |||C8|ADT-060A12AB B<br>ADT-060A15AB B<br>ADT-060A19AB B<br>ADT-060A24AB B| All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (July 2023, Rev. 05)** 3 **TECHINCAL DATASHEET** ## **AC-DC Adapter** ADT-60W Series / ADT-060A **□** A **□** B-A |||**Model Number**|ADT-060A12A☐B-A|ADT-060A15A☐B-A|ADT-060A19A☐B-A|ADT-060A24A☐B-A| |---|---|---|---|---|---|---| |Environment||||||| |Surrounding Air||Operating|-10°C to +60°C|||| |Temperature|||(-20°C cold start@100% Load)|||| |||Storage|-40°C to +85°C|||| |Power De-rating|||> 40°C de-rating power by 2.5% / °C|||| ||||< 90Vac de-rating power by2% / V|||| |OperatingHumidity|||5 to 95% RH(Non-Condensing)|||| |Storage Humidity|||5 to 95% RH(Non-Condensing)|||| |OperatingAltitude|||Upto 5,000 meters(upto 16,400 feet)|||| |Ball Impact Test|||Test height 130 cm,1 sam|1 sample 1 time,Steel Ball 500 g,Concrete floor||| |Drop Test|||Test height 100 cm, 6 face for each sample, concrete floor<br>Function testpass after droptest|||| |Shock Test||Non-Operating|Half sine wave,50 G,11|11 ms,1 shocks for each direction,6 direction||| |Vibration||Non-Operating|5-500 Hz,2.09 Grms,20 minute for X|20 minute for X,Y,Z axis||| |Protections||||||| |Overvoltage|||13.2-18.0 V,|16.5-22.5 V,|20.9-28.5 V,|26.4-36.0 V,| ||||Latch Mode|Latch Mode|Latch Mode|Latch Mode| ||||5.25-10.00 A|4.20-8.00 A|3.36-6.40 A|2.625-5.00 A| |Overload / Overcurrent|||Auto-Recoverywhen the fault is removed|||| |Over Temperature|||Latch Mode|||| |Short Circuit|||Auto-Recoverywhen the fault is removed|||| |Protection Against Shock||Protection Against Shock|ADT-060A12AA B|||| ||||ADT-060A15AA B|||| ||||ADT-060A19AA B|||| ||||ADT-060A24AA B<br>ADT-060A12AB B||Class II|| ||||ADT-060A15AB B|||| ||||ADT-060A19AB B|||| ||||ADT-060A24AB B|||| |Reliability Data|| |---|---| |MTBF|> 700,000 hrs. per Telcordia SR-332| ||at Input: 115 Vac,Output: 100% load,Ta: 25°C| |Expected CapLife Time|5years(50% load @ 25°C)| All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (July 2023, Rev. 05)** 4 **TECHINCAL DATASHEET** ## **AC-DC Adapter** ADT-60W Series / ADT-060A **□** A **□** B-A **==> picture [534 x 623] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---| |Model Number|ADT-060A12A|☐|B-A|ADT-060A15A|☐|B-A|ADT-060A19A|☐|B-A|ADT-060A24A|☐|B-A| |Safety Standards / Directives| |Electrical Safety|CB scheme|IEC/UL/EN 60950-1; IEC/UL/EN 62368-1| |BSMI|CNS 14336-1| |CCC|GB 4943.1-2011| |PSE|J 60950-1(H29)| |KC|K 60950-1| |Limited Power Source|CB scheme|IEC 62368-1| |(LPS)| |CE|In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU| |UKCA|In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical| |Equipment (Safety) Regulations 2016| |Galvanic Isolation|Input to Output|3000|Vac| |EMC| |Emissions (CE & RE)|CISPR/EN/BS EN 55032 Class B| |BSMI CNS 13438| |FCC Part 15, ICES-003, ANSI C63.4| |GB/T9254- 2008| |KN32| |Immunity|EN/BS EN 55024;|KN35| |Radiated and|Conducted Emissions: EN/BS EN 55032 Class B| |Conducted Emissions|Radiated Emissions: EN/BS EN 55032 Class B| |Flicker and Voltage|IEC 61000-3-3| |Fluctuation| |Harmonic Current|IEC 61000-3-2|Class D; GB 17625.1-2003| |Emissions| |Electrostatic|IEC 61000-4-2|Criteria A|[1) ]| |Discharge Standard|Air Discharge: 15|kV| |Contact Discharge: 8|kV| |Radiated Field|IEC 61000-4-3|Level 2 Criteria A|[1)]| |Immunity Test|80|MHz – 1|GHz, 3|V/M with 1|kHz tone / 80% modulation.| |Fast Transient Burst|IEC 61000-4-4|Level 2 Criteria A|[1)]|: 1|kV| |Immunity| |Surge Immunity|IEC 61000-4-5|Level 3 Criteria A|[1)]| |Requirement|Common Mode: 2|kV (12Ω) – For ADT-060A|☐☐|AA B-A model only| |Differential Mode: 1|KV (2Ω)| |Conducted Immunity|IEC 61000-4-6|Level 2 Criteria A|[1)]| |150|kHz – 80|MHz, 3|Vrms| |Power Frequency|IEC 61000-4-8|Level 2 Criteria A|[1)]| |Magnetic Fields|Magnetic field strength 3|A/m| |Voltage Dips,|IEC 61000-4-11|Voltage Dips| |Short Interruptions|70% reduction/0.5 periods (Criterion B)| |Immunity|40% reduction/5 periods (Criterion C)| |Voltage Short Interruptions| |5% reduction/250 periods (Criterion C)| **----- End of picture text -----**<br> ## Safety Standards / Directives EMC - 1) Criteria A: Normal performance within the specification limits - 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restore to normal operation after test. - 3) Criteria C: Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls by the user in accordance with the manufacturer’s instructions. All parameters are specified at 25°C ambient for all products unless otherwise indicated. | **www.DeltaPSU.com (July 2023, Rev. 05)** 5 **TECHINCAL DATASHEET** ## **AC-DC Adapter** ADT-60W Series / ADT-060A **□** A **□** B-A ## **Dimensions** **W x L x H:** 46.0 x 108.0 x 29.5 mm (1.81 x 4.25 x 1.16 inch) ## **Engineering Data** Output Load De-rating VS Surrounding Air Temperature **==> picture [343 x 232] intentionally omitted <==** **----- Start of picture text -----**<br> 110<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>-10 0 10 20 30 40 50 60 70<br>Surrounding Air Temperature (°C)<br>Output Load (%)<br>**----- End of picture text -----**<br> **Fig. 2 De-rating for All Mounting Orientation (All Models)** > 40°C de-rate power by 2.5% / °C All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (July 2023, Rev. 05)** 6 **TECHINCAL DATASHEET** ## **AC-DC Adapter** ADT-60W Series / ADT-060A **□** A **□** B-A ## Output Load De-rating VS Input Voltage **==> picture [340 x 207] intentionally omitted <==** **----- Start of picture text -----**<br> 110<br>100 ee ee ee ee es ee<br>a<br>90<br>80 es ee es<br>70 Ss ee A<br>60 Ss ee A<br>50 Ss ee A<br>40 Ss ee A<br>30 Ss ee A<br>20 Se ee es<br>10 a ee<br>0 Ss A OO<br>85 110 135 160 185 210 235 260<br>Input Voltage (Vac)<br>Output Load (%)<br>**----- End of picture text -----**<br> **Fig. 3 De-rating for Low Input Voltage (All Models)** < 90Vac de-rate power by 2% / Vac All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (July 2023, Rev. 05)** 7 **TECHINCAL DATASHEET** ## **AC-DC Adapter** ADT-60W Series / ADT-060A **□** A **□** B-A ## **Others** ## PFC – Norm EN 61000-3-2 ## **Line Current Harmonic content** Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to **www.DeltaPSU.com** for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. ## **Manufacturer and Authorized Representatives Information** ## Manufacturer ## Thailand Delta Electronics (Thailand) PCL. 909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand ## Taiwan Delta Electronics, Inc. 3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County 32063, Taiwan ## Authorized Representatives ## The Netherlands Delta Greentech (Netherlands) B.V. Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands ## United Kingdom Delta Electronics Europe Limited 1 Redwood Court, Peel Park Campus, East Kilbride, Glasgow, G74 5PF, United Kingdom All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (July 2023, Rev. 05)** 8
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →