Image not available
Illustrative purposes only
AC5002
Mounting Kit, DIN Top Hat Rail, HF4x/HF5X/HF6X/PF4 & PF5 Series Transmitters
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ROTRONIC
- Product type:
- SVHC: No SVHC (25-Jun-2025)
- For Use With: Rotronic HF4x/HF5X/HF6X/PF4 & PF5 Series Transmitters
- Accessory Type: DIN Top Hat Rail Mounting Kit
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 23.04 € |
| Current stock | 10+ |
| Lead time | 30 days |
Rotronic Product Catalogue
**mA V**
2022-V2
ABOUT ROTRONIC
## Rotronic measuring instruments: precision at the highest level
Based in Switzerland and established in 1965, Rotronic offers a wide range of handheld instruments, transmitters, (industrial) probes, data loggers, OEM products and monitoring systems. A world leader in relative humidity and temperature measurement, our portfolio also includes solutions for water activity, CO2 and differential pressure. We thus cover a wide range of applications from the pharmaceutical and food industries to HVAC and meteorology.
## Rotronic Monitoring System: modular, flexible and reliable
The Rotronic Monitoring System is a modular IoT system of interconnected hardware elements and software ee (on-premis or cloud options). It enables maximum flexibility in installation and guarantees excellent availability of the data during operation. The data loggers record all measurements by Rotronic and third-party sensors and transmit them to the database, which stores all the information reliably. Authorized users can access their data at any time via the browser/Internet from a PC, Mac, tablet or smartphone and set pao scace| alarms according to defined events =
## Rotronic – a PST company
Within the Process Sensing Technologies (PST) Group, Rotronic is the competence center for relative humidity and cloud-based monitoring systems. PST unites leading manufacturers who together offer a comprehensive and complementary suite of instruments, analyzers and sensors unmatched by other suppliers. PST opens up new areas of application for Rotronic and our customers benefit from a broader product range and sales network within the PST Group.
## Guarantee and services
Rotronic products guarantee reliability: we offer validated software and products that comply with international regulations such as GAMP and FDA.
- Highest accuracy at ± 0.5 %RH
- ISO 9001 quality with factory adjustment certificate
- ISO 17025 accredited calibration laboratories in CH, DE (SCS0065)
- ISO 17025 accredited laboratories in UK, USA
- Validated software
- Products compliant to current industry standards
- 24 months product warranty (12 months for HG2 calibration system and AwTherm water activity measuring instrument)
- More than 50 years of experience in humidity measurement
- Eco-friendly, professional and free disposal of old devices and accessories
2
2022-V2
Contents
|**Humidity and Temperature**||
|---|---|
|Probes & Filters|5|
|Transmitters|22|
|Data loggers|42|
|Handheld instruments|46|
|Calibration|50|
|Accessories|55|
|**Temperature**||
|Probes|63|
|---|---|
|Transmitters|65|
|Data loggers|68|
|**Differential pressure**||
|Transmitters|71|
|**CO2**||
|Data Loggers|75|
|Handheld instrument|77|
|Technical data<br>~~Se~~|78<br>~~Se~~|
|**Applications**||
|Water activity|80|
|Meteorology|87|
|Cleanrooms|95|
|ATEX|98|
## **Rotronic Monitoring System – RMS**
|Introduction|102|
|---|---|
|Software|104|
|Hardware|106|
|Accessories|123|
|**Software**||
|HW5|127|
## **EcoLine – Humidity & Temperature**
|Humidityand Temperatureprobes|130|
|---|---|
|Humidityand temperature transmitter|134|
|Humiditycalibrator|137|
|**Services**||
|Consultation,Validation,Calibration|141|
|Mapping<br>~~OC~~|143<br>~~OC~~|
|~~OC~~|~~OC~~|
|Seminar,Repair|144|
|Equipment hire|145|
|**Theory**||
|Measurementparameters: fundamentals|147|
3
2022-V2
**==> picture [515 x 472] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Humidity and Temperature|
|es|(IC)|
|Temperature|
|Differential pressure|
|©|
|CO2|
|Applications|
|Rotronic Monitoring System – RMS|
|@|
|Software|
|EcoLine – Humidity & Temperature|
|Services|
|Theory|
**----- End of picture text -----**<br>
**Video Humidity** Interested? Then scan the QR code!
4
2022-V2
Humidity and Temperature Probes & Filters
## Standard and high precision probes
## **HC2A-S / HC2A-S-HH / HC2A-S3 and HC2A-SH/HC2A-S3H**
The HC2A-S / HC2A-S-HH / HC2A-S3 is the most versatile probe from Rotronic and forms the basis of the product portfolio. It measures humidity and temperature and calculates the dew/frost point. The HC2A-SH/HC2A-S3H fulfills the highest demands for measuring accuracy.
## **APPLICATIONS**
HVAC, food industry, building services equipment, paper, textile and pharmaceutical industries.
## **FEATURES**
- Accuracy: standard probe (HC2A-S / HC2A-S-HH): ±0.8 %rh, ±0.1 K, at 10...30 °C
- Accuracy: high precision probe (HC2A-SH): ±0.5 %rh, ±0.1 K, at 10...30 °C
- Range of application: -50…100 °C / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V or Default analog scaling/ outputStandard: adjusted at 23 °C and 10, 35, 80 %rh
- High precision: adjusted at 23 °C and 10, 20, 30, 40, 50, 60, 70, 80, 90 %rh, then calibrated at 20, 50, 80 %rh
• Standard analog output scaling: 0…1 V = -40…60 °C / 0…100 %rh
**Order code HC2A-S / HC2A-S-HH / HC2A-S3 HC2A-SH / HC2A-S3H** Probe type S: black, S3: white SH: black, S3H: white Dimensions Ø 15 x 108 mm Range of application -50…100 °C, 0…100 %rh Accuracy HC2A-S-HH: ±1.0 %rh, ±0.1 ±0.5 %rh, ±0.1 K at 10...30 °C K at 10...30 °C (10...90 %rh) (10...90 %rh) Power supply 3.3…5 VDC, adjusted at 3.3 VDC Current consumption ~4.5 mA Long-term stability <1 %rh / year Sensor type ROTRONIC HYGROMER[®] HT-1 (HC2A-S-HH: HH-1), PT100 1/3 Class B Filter type S: polyethylene white, 40 μm SH: polyethylene white, 40 μm S3: polyethylene white, 40 μm S3H: polyethylene white, 40 μm Response time <15 s, without filter Max. wind 3 m/s, without filter velocity 20 m/s with polyethylene filter Housing material Polycarbonate ~~—~~ Weight / IP protection 10 g / IP65 The HC2A-S-HH is especially suitable for environments with hydrogen peroxide (H2O2) using the Hygromer®HH-1 sensor, without any filter.
HC2A-S HC2A-S3 HC2A-SH HC2A-S3H
O ~~C.~~
## **Compatible**
## **Recommended accessories**
- Handheld instruments
- Transmitters
- Meteorology transmitters
## **Delivery package**
- Factory adjustment certificate
- Short instruction manual
HP32 HF5, PF4, PF5 MP102H, MP402H
• Mounting flange AC5005 • Filters • Extension cable 2 m, black E2-02A • Adapter cable, open ends, 2 m E2-02XX-ACT/01 • Calibration device ER-15 • Humidity standard for calibration 10 %rh EA10-SCS • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS
- Polyethylene filter
5
2022-V2
Humidity and Temperature Probes & Filters
~~we~~
## Meteorological Probe
## **HC2A-S3A**
The HC2A-S3A probe is the meteorological probe with a white housing but with a different filter (Wire-mesh filter with 10 µm filter pore size suitable for meteorological applications). It measures relative humidity and temperature and calculates the dew/frost point and is designed for the use in Rotronic meteorological applications.
## **APPLICATIONS**
Meteorology, weather stations, snow cannon
## **FEATURES**
- Accuracy: ±0.8 %rh, ±0.1 K, at 10...30 °C
- Range of application: -50…80 °C[1] * / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
• Standard analog output scaling: 0…1 V = -40…60 °C / 0…100 %rh
**Order code HC2A-S3A** Probe type white Dimensions Ø 15 x 108 mm Range of application -50…80 °C[1] , 0…100 %rh Accuracy ±0.8 %rh, ±0.1 K at 10...30 °C Power supply 3.3…5 VDC, adjusted at 3.3 VDC Current consumption ~4.5 mA Long-term stability <1 %rh / year[2] Sensor type ROTRONIC HYGROMER[®] HM1-SK PT100 1/3 Class B Filter type wire mesh 1.4401, 10 um Response time <15 s, without filter Max. wind velocity 3 m/s, without filter Housing material Polycarbonate ~~=~~ Weight / IP protection 10 g / IP65 *[1] : The sensor withstands only 60 °Cdp *[2] : Drift < 1%rh per year with clean air or ismilar (see also pollutant table in the catalogue)
HC2A-S3A
## **Compatible**
## **Recommended accessories**
- Handheld instruments
- Transmitters
- Meteorology transmitters
- Naturally Ventilated Shields
- Actively Ventilated Shields
## **Delivery package**
HP32 HF5, PF4, PF5 MP102H, MP402H AC1000 RS12-T or RS24-T
• Mounting flange AC5005 • Filters • Extension cable 5 m, white E3-05A • Calibration device ER-15 • Humidity standard for calibration 10 %rh EA10-SCS • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS
- Factory adjustment certificate
- Short instruction manual
- Wire-mesh filter
6
2022-V2
Humidity and Temperature Probes & Filters
## Industrial probes, steel
The HC2A-SM is the robust probe from Rotronic for harsh environments and adds to the wide product portfolio. It measures humidity and temperature and calculates the dew/frost point.
## **APPLICATIONS**
Food, paper, textile, pharmaceutical and cosmetic industries.
## **FEATURES**
- Accuracy: ±0.8 %rh, ±0.1 K, at 10...30 °C
- Range of application: -50…100 °C / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
- Standard analog output scaling: 0…1 V = -40…60 °C / 0…100 %rh
- Adjusted at 23 °C and 10, 35, 80 %rh
|**Order code**|**HC2A-SM**|
|---|---|
|Probe type|Chrome steel standard|
|Dimensions|Ø 15 x 109 mm|
|Range of application|-50…100 °C,0…100 %rh|
|Accuracy|±0.8 %rh,±0.1 K,at 10...30 °C|
|Power supply|3.3…5 VDC,adjusted at 3.3 VDC|
|Current consumption|~4.5 mA|
|Long-term stability|<1 %rh/ year|
|Sensor type|ROTRONIC HYGROMER®HT-1,PT100 1/3 Class B|
|Filter type|Wire mesh filter|
|Response time|<15 s,without filter|
|Max. wind<br>velocity|3 m/s, without filter<br>25 m/s with wire mesh filter|
|Housingmaterial|Stainless steel 1.4301|
|Weight/IPprotection|47g /IP65|
**==> picture [34 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
HC2A-SM<br>**----- End of picture text -----**<br>
Available with ATEX certificate
## **Compatible**
## **Recommended accessories**
- Handheld instruments
- Transmitters
## **Delivery package**
- Factory adjustment certificate
- Short instruction manual
HP32 HF5, PF4, PF5
• Mounting gland AC1303-M • Filters • Extension cable 2 m, metal connector E2-02A-M • Calibration device ER-15 • Humidity standard for calibration 10 %rh EA10-SCS • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS
- Wire mesh filter
7
2022-V2
Humidity and Temperature Probes & Filters
## Industrial cable probes
The Rotronic industrial probe is especially suitable for high temperatures and demanding industrial environments. It measures humidity and temperature and calculates the dew/frost point.
## **APPLICATIONS**
Production environments, high temperatures, industrial manufacturing, drying processes, climate chambers.
## **FEATURES**
- Accuracy: ±0.8 %rh, ±0.1 K, at 10...30 °C
- Range of application: -100…200 °C[1] (HC2-HK40)/ 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
- Standard analog output scaling: 0…1 V = -40…60 °C / 0…100 %rh
- Adjusted at 23 °C and 10, 35, 80 %rh
## **Industrial probes**
## **Ø 15 mm**
|**Order code**|**HC2A-IC1xx***|**HC2A-IC302**|
|---|---|---|
|Dimensions|Ø 15 x 144 mm|Ø 15 x 294 mm|
|Accuracy|±0.8 %rh,±0.1 K,at 10...30 °C||
|Power supply|3.3…5 VDC,adjusted at 3.3 VDC,current: ~4.5 mA||
|Sensor type|ROTRONIC HYGROMER®HT-1,PT100 1/3 Class B||
|Response time|<15 s,without filter||
|Material|PPS,stainless steel 1.4301||
|Weight|230g|260g|
|* xx = cable length in meters(02,05),80g per meter cable|||
## **Industrial probes**
## **Ø 15/25 mm**
|**Order code**|**HC2A-IC402-A**|**HC2A-IC702-A**|
|---|---|---|
|Dimensions|Ø 15/25 x 428 mm|Ø 15/25 x 728 mm|
|Accuracy|±0.8 %rh,±0.1 K,at 10...30 °C||
|Power supply|3.3…5 VDC,adjusted at 3.3 VDC,current: ~4.5 mA||
|Sensor type|ROTRONIC HYGROMER®HT-1,PT100 1/3 Class B||
|Response time|<15 s,without filter||
|Material|PPS,stainless steel 1.4301||
**==> picture [143 x 204] intentionally omitted <==**
**----- Start of picture text -----**<br>
O 15 mm<br>O 15 mm<br>O 25 mm<br>HC2A-ICxxx HC2A-ICxxx-A<br>mm 428 / 728 mm<br>384 / 684 mm<br>111 mm<br>150<br>144 mm / 294 mm<br>**----- End of picture text -----**<br>
- **Compatible Recommended accessories** • Handheld instruments HP32 • Filters • Transmitters HF5, PF4, PF5 • Humidity standard for calibration 10 %rh EA10-SCS • Humidity standard for calibration 35 %rh EA35-SCS
- **Delivery package** • Humidity standard for calibration 80 %rh EA80-SCS • Factory adjustment certificate 1 Peak load: 100 h Permissible continuous load: 190 °C
- ~~oo~~ 8
- 2022-V2
Humidity and Temperature Probes & Filters Industrial cable probes, steel The metal industrial probe is especially suitable for high temperatures, demanding industrial ~~ee~~ environments and applications where hygiene plays an important role. The probe measures humidity and temperature and calculates the dew/frost point.
## **APPLICATIONS**
Food and pharmaceutical production, drying processes, industrial manufacturing.
## **FEATURES**
- Accuracy: ±0.8 %rh, ±0.1 K, at 10...30 °C
- Range of application: -100…200 °C[1] , (screw-in probe; -100…200 °C[1] ) / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
- Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
- Adjusted at 23 °C and 10, 35, 80 %rh
## **Steel industrial probes**
## **Ø 15/25 mm**
|**Order code**|**HC2A-IM102-M**|**HC2A-IM3xx-M***|
|---|---|---|
|Dimensions|Ø 15 x 130 mm|Ø 15 x 280 mm|
|Accuracy|±0.8 %rh,±0.1 K,at 10...30 °C||
|Power supply|3.3…5 VDC,adjusted at 3.3 VDC,current: ~4.5 mA||
|Sensor type|ROTRONIC HYGROMER®HT-1,PT100 1/3 Class B||
|Response time|<15 s,without filter||
|Housingmaterial|Stainless steel,DIN 1.4301||
|Weight|260g|400g|
|* xx = cable length in meters(02,05),80g per meter cable|||
## **Screw-in probes**
## **Ø 15 mm**
|**Order code**|**HC2A-IE02-G**|**HC2A-IE02-NPT**|
|---|---|---|
|Probe type|½" G with Rotronic connector|½" NPT with Rotronic connector|
|Accuracy|±0.8 %rh,±0.1 K,at 10...30 °C||
|Power supply|3.3…5 VDC,adjusted at 3.3 VDC,current: ~4.5 mA||
|Sensor type|ROTRONIC HYGROMER®HT-1,PT100 1/3 Class B||
|Sensor typ<br>Pressure<br>Resonse time|,/3 Class B<br>Pressure resistant to 100 bar/1450 PSI<br><15 swithout filter||
|Response time|<15 s,without filter||
|Housingmaterial|Stainless steel,DIN 1.4301||
|Weight|290g||
**==> picture [158 x 116] intentionally omitted <==**
**----- Start of picture text -----**<br>
O 15 mm<br>ae<br>n=<br>Ø15 mm<br>G1/2<br>SW 27<br>HC2A-IMxxx-M HC2A-IExxx<br>mm<br>mm 97 mm<br>97 148<br>130 / 280 mm<br>**----- End of picture text -----**<br>
## **Compatible**
## **Recommended accessories**
- Handheld instruments
- Transmitters
## **Delivery package**
- Factory adjustment certificate
HP32 HF5, PF4, PF5
- Filters
- Calibration device (HC2A-IM)
- Humidity standard for calibration 10 %rh
- Humidity standard for calibration 35 %rh
- Humidity standard for calibration 80 %rh
- 1 Peak load: 100 h
ER-15 EA10-SCS EA35-SCS EA80-SCS
- Permissible continuous load: 190 °C
9
2022-V2
Humidity and Temperature Probes & Filters
## High temperature handheld probes
The handheld probe is especially suitable for portable measurements of high temperatures. It measures humidity and temperature and calculates the dew/frost point.
## **APPLICATIONS**
Climate and temperature chambers, dryers, air ducts.
## **FEATURES**
- Accuracy: ±0.8 %rh, ±0.1 K, at 10...30 °C
- Range of application: -100...170 °C/200 °C[1] / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
- Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
- Adjusted at 23 °C and 10, 35, 80 %rh
|**Order code**|**HC2-HK25**|**HC2-HK40**|
|---|---|---|
|Probe type|Handheldprobe||
|Dimensions|Ø 15 x 250 mm|Ø 15 x 400 mm|
|Accuracy|±0.8 %rh,±0.1 K,at 10...30 °C||
|Power supply|3.3…5 VDC,adjusted at 3.3 VDC,current: ~4.5 mA||
|Sensor type|ROTRONIC HYGROMER®IN-1,PT100 1/3 Class B||
|Response time|<15 s,without filter||
|Housingmaterial|PEEK,brass,chemicallynickel-plated||
|Weight|210g<br>Wire mesh filter|240g|
|Filter|Wire mesh filter||
|Cable length|2 m||
**==> picture [80 x 291] intentionally omitted <==**
**----- Start of picture text -----**<br>
15<br>25<br>15<br>75<br>35<br>60<br>131<br>250 / 400<br>(HK25 / HK40)<br>39<br>**----- End of picture text -----**<br>
**Compatible Recommended accessories** • Handheld instruments HP32 • Filters • Transmitters HF5, PF4, PF5 • Calibration device ER-15 • Humidity standard for calibration 10 %rh EA10-SCS **Delivery package** • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS • Factory adjustment certificate • Wire mesh filter 1 Short-term peak load (3 x 5 min) ~~oo~~ 10 2022-V2
**==> picture [554 x 717] intentionally omitted <==**
**----- Start of picture text -----**<br>
Humidity and Temperature Probes & Filters<br>HygroWin USB probe<br>The USB probe measures humidity and temperature.<br>APPLICATIONS<br>Residential and office<br>FEATURES<br>• Connects directly to a PC on a USB port<br>• Range of application: -50…100 °C / 0…100 %rh<br>• Adjusted at 23 °C and 10, 35, 80 %rh<br>Order code HC2A-WIN-USB-1<br>Probe type HC2A probe with direct USB connection<br>Accuracy ±0.8 %rh, ±0.1 K, at 10...30 °C<br>Power supply Via USB cable<br>Sensor type ROTRONIC HYGROMER [®] HT-1, PT100 1/3 Class B<br>Filter type Polyethylene standard filter, 20 µm, gray<br>Response time <15 s, without filter<br>Weight 110 g<br>Housing material Polycarbonate<br>4 Cable length 3 m<br>Delivery package Recommended accessories<br>• Factory adjustment certificate • Calibration device ER-15<br>**----- End of picture text -----**<br>
- ER-15 EA10-SCS EA35-SCS EA80-SCS
- HW5 (free software)
- Humidity standard for calibration 10 %rh
- Service and adapter cable AC3001
- Humidity standard for calibration 35 %rh
- Humidity standard for calibration 80 %rh
11
2022-V2
Humidity and Temperature Probes & Filters
## Miniature probes
The miniature probe is used for humidity and temperature measurement in confined spaces. It also calculates the dew/frost point and can be installed discretely. The 4 mm probe has a spike tip for insertion in walls.
## **APPLICATIONS**
Museums, glass cabinets, building material tests, automotive and aviation industries, testing laboratories, paper, textile and pharmaceutical industries.
## **FEATURES**
**==> picture [552 x 513] intentionally omitted <==**
**----- Start of picture text -----**<br>
• Accuracy: ±1.5 %rh, ±0.3 K, at 10...30 °C<br>• Range of application: -40…85 °C / 0…100 %rh<br>• Digital interface (UART) and scalable analog outputs, 0…1 V<br>• Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh<br>• Adjusted at 23 °C and 10, 35, 80 %rh<br>Order code HC2-C04 HC2-C05<br>Probe type Cable probe, Ø 4 mm Cable probe, Ø 5 mm<br>Accuracy ±1.5 %rh, ±0.3 K, at 10...30 °C<br>Power supply 3.3…5 VDC, adjusted at 3.3 VDC, current: ~4.5 mA<br>Sensor type ROTRONIC HYGROMER [®] IN-1, PT100 1/3 Class B<br>Response time <15 s, without filter<br>Housing material Stainless steel, DIN 1.4305 Brass, nickel-plated<br>Weight 85 g 85 g<br>a Cable length 2 m<br>15 15<br>it<br>4 5<br>t<br>HC2-C04 HC2-C05<br>Compatible Recommended accessories<br>• Handheld instruments HP32 • Extension cable 2 m, black E2-02A<br>103 103<br>57<br>51<br>**----- End of picture text -----**<br>
- Extension cable 2 m, black
HP32 HF5, PF4, PF5
- Extension cable 2 m, black E2-02A • Teflon filter for HC2-C05 SP-T05 • Calibration device ER-05 • Humidity standard for calibration 10 %rh EA10-SCS • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS
- Transmitters
## **Delivery package**
- Factory adjustment certificate
12
2022-V2
Humidity and Temperature Probes & Filters
## Insertion probes
## **Ø 5 mm / 10 mm**
The insertion probe is suitable for measurement in dust-free (P05) or dusty (HP28/50) bulk materials, bricks, concrete, etc. It measures humidity and temperature and calculates the dew/frost point. **APPLICATIONS** Water activity measurement Portable measuring units with handheld instruments **FEATURES** • Accuracy: ±0.8/1.5 %rh, ±0.1/0.3 K, at 10...30 °C • Range of application: -40…85 °C / 0…100 %rh • Digital interface (UART) • Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh • Adjusted at 23 °C and 10, 35, 80 %rh **Order code HC2-P05** Probe type Ø 5 x 200 mm, insertion probe with laser cut slots Accuracy ±1.5 %rh, ±0.3 K, at 10...30 °C Power supply 3.3…5 VDC, adjusted at 3.3 VDC, current: ~4.5 mA Filter type No filter available Sensor type ROTRONIC HYGROMER[®] IN-1, PT100 1/3 Class B Response time <15 s Material Stainless steel DIN 1.4305 (probe), POM (handle) Weight 160 g ~~—A~~ Cable length 2 m 15 **Order code HC2-HP28** Probe length Ø 10 x 280 mm Accuracy ±0.8 %rh, ±0.1 K, at 10...30 °C Power supply 3.3…5 VDC, adjusted at 3.3 VDC, current: ~4.5 mA Filter type Sintered steel Sensor type ROTRONIC HYGROMER[® ] IN-1, PT100 1/3 Class B Response time <20 s, with filter Material Stainless steel DIN 1.4305 (probe), POM (handle) 25 Weight 200 g Cable length 2 m 5 HC2-P05 HC2-HPxx
## **Compatible**
- Handheld instruments
- Transmitters
- Laboratory analyzer
## **Delivery package**
HP32 HF5, PF4, PF5 HygroLab
## **Recommended accessories**
- Replacement filter (HC2-HP28 / 50 sintered steel)
- ET-Z10
- • Calibration device HC2-P05 ER-05 • Humidity standard for calibration 10 %rh EA10-SCS • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS
- Factory adjustment certificate
13
2022-V2
Humidity and Temperature Probes & Filters Sword probes 15 **APPLICATIONS** Paper, printing and textile industries with handheld instruments. **FEATURES** • Accuracy: ±0.8 %rh, ±0.1 K, at 10...30 °C • Range of application: -40…85 °C / 0…100 %rh • Digital interface (UART) and scalable analog outputs, 0…1 V • Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh • Adjusted at 23 °C and 10, 35, 80 %rh 25 **Order code HC2-HS28** Probe length 280 mm 18 Accuracy ±0.8 %rh, ±0.1 K, at 10...30 °C Power supply 3.3…5 VDC, adjusted at 3.3 VDC, current: ~4.5 mA Filter type No filter Sensor type ROTRONIC HYGROMER[®] IN-1, PT100 1/3 Class B Response time <15 s Material Aluminum (probe), POM (handle) Weight 220 g ~~—I~~ Cable length 2 m Va **Compatible Recommended accessories** • Handheld instruments HP32 • Calibration device (sword probe) EGS
- Calibration device (sword probe)
- EGS EA10-SCS EA35-SCS EA80-SCS
HP32 HF5, PF4, PF5
- Humidity standard for calibration 10 %rh
- Transmitters
- Humidity standard for calibration 35 %rh
## **Delivery package**
- Humidity standard for calibration 80 %rh
- Factory adjustment certificate
14
2022-V2
Humidity and Temperature Probes & Filters
## XD OEM probes
Thanks to its wide power supply range and freely selectable output signals, the XD OEM probe is suitable for a wide variety of applications.
## **APPLICATIONS**
HVAC, climate chambers, snow guns and meteorology.
## **FEATURES**
- Accuracy: ±0.8 %rh, ±0.2 K, at 10...30 °C
- Housing colors: black
- Range of application: -40…85 °C / 0…100 %rh
- UART digital interface
- Various voltage outputs available
- Adjusted at 23 °C and 10, 35, 80 %rh
- Freely scalable output signals: 0…1/5/10 VDC*
**==> picture [282 x 160] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Order code|XD3xA-S3X*|
|Housing color|Black|
|Range of application|-40...85 °C|
|Accuracy|±0.8 %rh, ±0.2 K, at 10...30 °C|
|5…24 VDC / 5…16 VAC (0...1 V)|
|Power supply|
|16...24 VDC / 12...16 VAC (all output versions)|
|Current consumption|<12 mA|
|Long-term stability|<1 %rh /|year|
|Sensor type|ROTRONIC HYGROMER|[®]|HT-1, PT100 1/3 Class B|
|Filter type|Polyethylene standard filter, 20 µm, white|
|Response time|<15 s, without filter|
|Housing material|Polycarbonate|
|Weight|20 g|
|* x = Output (3: 0...1 V, 4: 0...5 V, 5: 0...10 V)|
**----- End of picture text -----**<br>
**Note:** Not compatible with Rotronic data loggers, transmitters or handheld instruments.
**==> picture [6 x 177] intentionally omitted <==**
## **Delivery package**
- Factory adjustment certificate
- Polyethylene filter
- Short instruction manual
- Requires optional HW5 software and service cable
## **Recommended accessories**
• Mounting flange AC5005 • Filters • Extension cable 2 m, with open ends, black E2-02XX • Calibration device ER-15 • Humidity standard for calibration 10 %rh EA10-SCS • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS • Service cable to PC XD-AC3001
15
2022-V2
Humidity and Temperature Probes & Filters
## Filter / Carrier HC2A advanced probes
## **DESCRIPTION**
Filter carriers protect the humidity and temperature sensors against mechanical damage. Filters act as a protective barrier against contaminants/ pollutants that can influence the sensor. When choosing the correct combination of filter carrier and filter there are many factors to consider. Specific conditions such as high air velocities, pollutants in the air, disinfection and cleaning routines, mechanical impacts, high bioactivity, condensation, airborne chemical contaminants and required response time are some of the many considerations.
|**Plastic filter carrier**||**Metal filter carrier**|||
|---|---|---|---|---|
|• Maximum temperature 100 °C<br>• Mechanical protection||• Maximum temperature 200 °C<br>• Mechanical protection||la|
|**Overview filters**|||||
||Teflon filters|Polyethylene<br>filters|Sintered steel filters<br>(stainless steel)|Wire mesh filters<br>(metal)|
|Maximum temperature<br>(consider range of application of filter carrier)|200 °C|100 °C|200 °C|200 °C|
|Protection againstparticulates| | |||
|Protection against abrasives in the air||| ||
|Pore size|10µm|40µm|25µm|10µm|
|Max. air velocity [m/s] (continuous load)|50|50|70|50|
= low = medium = high
|Filters & carriers|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|**Overviewprobes**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||**Range of application(temp.)**||**-50…100 °C**||||||**-40…85°C**|**-100…200°C**||||
||Probe||HC2A-S|HC2A-S3|HC2A-SH|HC2A-S3H|HC2A-S-HH|HC2A-SM|XD33A-S3X|HC2A-ICxxx|HC2A-Icxxx-A|HC2A-IMxxx-M|HC2A-IExxx|
||-50…100 °C|SPA-PCB||||||||||||
|||SPA-PCW||||||||||||
||-100…200°C|SPA-SS||||||||||||
||-50…100 °C|SPA-PCB-PE||||||||||||
|||SPA-PCB-PTFE||||||||||||
|||SPA-PCB-WM||||||||||||
|||SPA-PCW-PE||||||||||||
|||SPA-PCW-PTFE||||||||||||
|||SPA-PCW-WM||||||||||||
|||SPA-SS-PE||||||||||||
|||SPA-PE||||||||||||
||-100…200°C|SPA-SS-PTFE||||||||||||
|||SPA-SS-WM||||||||||||
|||SPA-SSS||||||||||||
|||SPA-WM||||||||||||
|||SPA-PTFE||||||||||||
16
2022-V2
Humidity and Temperature Probes & Filters
## **HC2A-S / HC2A-S3 / HC2A-SH / HC2A-S3H / HC2A-S-HH / HC2A-SM**
|**Order code**|**Filter carrier**|**Filter element**|**Pore size**|**Range of application**||
|---|---|---|---|---|---|
|SPA-PCB|Polycarbonate, black|No filter, only filter carrier||-50…100 °C|Stan oe)|
|SPA-PCB-PE||Polyethylene, white|40-50 µm||~~-)~~|
|SPA-PCB-PTFE||PTFE, white|10 µm||~~-)~~|
|SPA-PCB-WM||Wire mesh 1.4401|10 µm||~~—~~|
|SPA-PCW|Polycarbonate, white|No filter, only filter carrier||-50…100 °C||
|SPA-PCW-PE||Polyethylene, white|40-50 µm|||
|SPA-PCW-PTFE||PTFE, white|10 µm|||
|SPA-PCW-WM||Wire mesh 1.4401|10 µm|||
|SPA-PE|No filter carrier,<br>only filter|Polyethylene, white|40-50 µm|||
|SPA-PTFE<br>**Particulate filter**|No filter carrier,<br>only filter<br>|PTFE, white|10 µm|-100…200 °C||
|**Particulate filter/ Waterproof**||||||
|SPA-POM-FD2|POM white|Teflon|2 µm|-50…100 °C||
|SPA-PE-FD2|POM white|Polyethylene|2 µm|||
## **HC2A-IC / HC2A-IM / HC2A-IE**
|**Order code**|**Filter carrier**|**Filter element**|**Pore size**|**Range of application**||
|---|---|---|---|---|---|
|SPA-SS|1.4301|No filter, only filter carrier||-100…200 °C||
|SPA-SS-PTFE||PTFE, white|10 µm|||
|SPA-SS-WM||Wire mesh 1.4401|10 µm||Aa|
|SPA-SSS|Filter carrier incl. filter|Sintered steel<br>1.4404|25 µm|||
|SPA-WM|No filter carrier,<br>only filter|Wire mesh 1.4401|10 µm|||
17
2022-V2
Humidity and Temperature Probes & Filters
## **HC2A-SM**
|**Order code**|**Filter carrier**|**Filter element**|**Pore size**|**Range of application**||
|---|---|---|---|---|---|
|SPA-SS|1.4301|No filter, only filter carrier||-50…100 °C|a)|
|SPA-SS-PTFE||PTFE, white|10 µm||y<br>|<br>~~)~~|
|SPA-SS-WM||Wire mesh 1.4401|10 µm||a|
|SPA-SSS|Filter carrier incl. filter|Sintered steel<br>1.4404|25 µm|-100...200 °C||
|SPA-WM|No filter carrier,<br>only filter|Wire mesh 1.4401|10 µm|||
## **Note**
The range of application depends on the component with the smallest temperature range.
18
2022-V2
Humidity and Temperature Probes & Filters
## Filter / Carrier HC2 probes
## **DESCRIPTION**
Filter carriers protect the humidity and temperature sensors against mechanical damage. Filters act as a protective barrier against contaminants/ pollutants that can influence the sensor. When choosing the correct combination of filter carrier and filter there are many factors to consider. Specific conditions such as high air velocities, pollutants in the air, disinfection and cleaning routines, mechanical impacts, high bioactivity, condensation, airborne chemical contaminants and required response time are some of the many considerations.
|**Plastic filter carrier**|**Metal filter carrier**|
|---|---|
|• Maximum temperature 120 °C<br>• Mechanical protection|• Maximum temperature 200 °C<br>• Mechanical protection|
|**Overview filters**|**Overview filters**|**Overview filters**|**Overview filters**|**Overview filters**|**Overview filters**|**Overview filters**|
|---|---|---|---|---|---|---|
||Teflon<br>filters|Polyethylene<br>filters|MFD filters<br>(membrane)|Polypropylene<br>filters(screen)|Sintered steel filters<br>(stainless steel)|Wire mesh<br>filters(metal)|
|Maximum temperature (consider range<br>of application of filter carrier)|200 °C|100 °C|120 °C|120 °C|200 °C|200 °C|
|Protection againstparticulates| | |||||
|Protection against abrasives in the air||||| ||
|Fast response time(low damping)|||| |||
|Pore size|10µm|40µm|-|150µm|25µm|10µm|
|Max. air velocity [m/s] (continuous load)|50|50|15|10|70|50|
= low = medium = high
## **Suitable for standard probes HC2-S / HC2-S3 / Thread: Rotronic round thread**
|**Order code**|**Filter carrier**|**Filter element**|**Pore size**|**Range of application**||
|---|---|---|---|---|---|
|NSP-PCB-PE|Polycarbonate, black|Polyethylene, gray|20µm|-50…100 °C|—|
|NSP-PCB-PE40||Polyethylene,white|40µm|||
|NSP-PCB-WM||Wire mesh|20…25µm|||
|NSP-PCB-TF||Teflon|10µm|||
|NSP-PCB-MFD||MFD|−|||
|NSP-PCB-PP100||Polypropylene|150µm|||
|NSP-PCB||No filter element, only carrier|||~~—~~|
|NSP-PCW-PE|Polycarbonate, white|Polyethylene, gray|20µm|-50…100 °C||
|NSP-PCW-PE40||Polyethylene,white|40µm|||
|NSP-PCW-WM||Wire mesh|20…25µm|||
|NSP-PCW-TF||Teflon|10µm|||
|NSP-PCW||No filter element, only carrier||||
|NSP-PE|No carrier, only filter||20 µm|-50…100 °C||
|**Particulate filter/ Waterproof**||||||
|NSP-POM-FD2|POM, white|Teflon|2 µm|-50…100 °C|CO|
19
2022-V2
Humidity and Temperature Probes & Filters
**Suitable for industrial probes HC2-IC / HC2-HK Thread: Rotronic round thread**
|**Order code**|**Filter carrier**|**Filter element**|**Pore size**|**Range of application**||
|---|---|---|---|---|---|
|NSP-ME-WM|Brass, nickel-plated|Wire mesh<br>DIN 1.4401|20…25 µm|-100...200 °C|~~ia~~|
|NSP-ME-SS||Sintered steel<br>DIN 1.4401|5 µm|-100...200 °C|~~=~~||
|NSP-ME-TF||Teflon|10 µm|-80...200 °C|~~=?~~|
|**Spareparts**||||||
|SP-M15|No filter carrier,<br>only filter|Wire mesh<br>DIN 1.4401|20…25 µm|-100...200 °C|~~a~~<br>C> F|
|SP-S15|No filter carrier,<br>only filter|Sintered steel<br>DIN 1.4401|5 µm|-100...200 °C|Om!|
|SP-T15|No filter carrier,<br>only filter|Teflon|10 µm|-80...200 °C|& ®|
**Suitable for industrial probes HC2-IM / HC2-IE Thread: M12 x 1.5**
|**Order code**|**Filter carrier**|**Filter element**|**Pore size**|**Range of application**||
|---|---|---|---|---|---|
|SP-MC15|Brass, nickel-plated|Wire mesh<br>DIN 1.4401|20…25 µm|-100...200 °C|Fy|
|SP-SC15||Sintered steel<br>DIN 1.4401|5 µm|-100...200 °C|~~=~~||
|SP-TC15||Teflon|10 µm|-80...200 °C|=<br>3?|
|**Spareparts**||||||
|SP-MSB15|Brass, nickel-plated|No filter element, only carrier||-100...200 °C|——|
|SP-M15|No filter carrier,<br>only filter|Wire mesh<br>DIN 1.4401|20…25 µm|-100...200 °C|a CD?|
|SP-S15|No filter carrier,<br>only filter|Sintered steel<br>DIN 1.4401|5 µm|-100...200 °C|on<br>ha|
|SP-T15|No filter carrier,<br>only filter|Teflon|10 µm|-80...200 °C|& ®|
20
2022-V2
Humidity and Temperature Probes & Filters
## **Suitable for handheld probes HC2-HP28/HP50**
|**Order code**|**Filter carrier**|**Filter element**|**Pore size**|**Range of application**|
|---|---|---|---|---|
|ET-Z10|No filter carrier,<br>only filter|Sintered steel<br>DIN 1.4401|15 µm|-40...85 °C|
|**Suitable for HF3 type R & S**|||||
|**Order code**|**Filter carrier**|**Filter element**|**Pore size**|**Range of application**|
|NSP-PCG-PE|Polycarbonate, gray|Polyethylene, gray|20 µm|-40...85 °C|
## **Suitable for HF3 type R & S**
## **Suitable for HF3 type D & W**
|**Order code**|**Filter carrier**|**Filter element**|**Pore size**|**Range of application**|
|---|---|---|---|---|
|SPA-PCW-PE|Polycarbonate, white|Polyethylene, white|40-50 µm|-50…100 °C|
## **Suitable for MP100A/400A**
|**Order code**|**Filter carrier**|**Filter element**|**Pore size**|**Range of application**|
|---|---|---|---|---|
|SP-W3-25|Polycarbonate, white|Wire mesh|20 µm|-40...85 °C|
## **Suitable for web and water activity probes AwEasy, HC2A-AW-USB, HC2A-AW, HC2-AW-USB, HC2-AW**
|**Order code**|**Description**|
|---|---|
|ET-W24-Set|Flat wire mesh filter with circlip, Ø 24 mm for HC2-AW (-USB)<br>Pore size: 20…25 μm|
## **Suitable for HF1, CP11, CL11**
|**Order code**|**Description**|
|---|---|
|NSP-PCB-PE-AZ|Polycarbonate filter for HF1, CP11, CL11, CF1|
21
2022-V2
Humidity and Temperature Transmitters
## The HygroFlex series
||Qo<br>:<br>=<br>@<br>{<br>||3<br>rortronic<br>=<br>oe|=<br>A)<br>C)<br>| ae<br>-|
|---|---|---|---|
|**Transmitters**|**HF1**|**HF3**|**HF4**|
|Range of application electronics<br>with displayoption|-20...60 °C<br>-20...60 °C|-40…60 °C<br>-10…60 °C|-40…60 °C<br>-10…60 °C|
|Temperature limits atprobe|-20...60 °C|-40...60 °C|-50…100 °C|
|Accuracy at 23 °C|**Type W & D & F:**<br><± 2 %rh (10...90 %rh) at ±0.3 K<br>**Type S:**<br><± 3 %rh(10...90 %rh)at ±1 K|±2 %rh<br>±0.3 K|±1 %rh<br>±0.2 K|
|**Probes**||||
|Probe connection|Not interchangeable|Not interchangeable|Not interchangeable|
|**Housing**||||
|Space mount version||||
|Wall version||||
|Duct version,15 mmprobe||||
|Duct version,25/15 mmprobe||||
|Cable version||||
|Display||||
|Keypad||||
|IPprotection|IP65(space mount version IP20)|IP65(space mount version IP20)|IP65|
|**Power supply**||||
|15…40 VDC/12…28 VAC||||
|15…40 VDC / 12…28 VAC<br>galvanicallyisolated||||
|85…240 VACgalvanicallyisolated||||
|Power over Ethernet(POE)||||
|**Output**||||
|2 or 2 x 2-wire: current output|2x|2x|2x|
|3/4-wire: current or voltage output|2x|2x|2x|
|RS-485||||
|Ethernet||||
|Wireless||||
|Analogand digital signals||||
|**Functions**||||
|Data logging||||
|Relay||||
|Hygrostat/Thermostat||||
|Beeptone||||
|Analoginput||||
|Psychrometricparameters||Dew/Frostpoint|Dew/Frostpoint|
22
2022-V2
Humidity and Temperature Transmitters
## The HygroFlex series
||EG)<br>1)<br>;<br>|<br>a<br>“<br>l|—<br>.<br>‘J<br>|<br>a<br>“<br>_<br>s<br>s<br>r<br>l|
|---|---|---|
|**Transmitters**|**HF5/ HS5**|**HF732A**|
|Range of application electronics<br>with displayoption|-40…60 °C<br>-10…60 °C|-40…85 °C<br>-10…60 °C|
|Temperature limits atprobe|Probe dependent|-100…200 °C(type D)|
|Accuracy at 23 °C|Probe dependent|±1 %rh<br>±0.2 K|
|**Probes**|||
|Probe connection|1x interchangeable HC2probe|Not interchangeable|
|**Housing**|||
|Space mount version|||
|Wall version|||
|Duct version, 15 mmprobe|||
|Duct version, 25/15 mmprobe|||
|Cable version|||
|Display|||
|Keypad|||
|IPprotection|IP65|IP65|
|**Power supply**|||
|15…40 VDC/12…28 VAC|||
|15…40 VDC/12…28 VACgalvanicallyisolated|||
|85…240 VACgalvanicallyisolated|||
|Power over Ethernet(POE)|||
|**Output**|||
|2 or 2 x 2-wire: current output|2x||
|3/4-wire: current or voltage output|2x|2x|
|RS-485|||
|Ethernet|||
|Wireless|||
|Analogand digital signals|||
|**Functions**|||
|Data logging|||
|Relay|||
|Hygrostat/Thermostat|||
|Beeptone|||
|Analoginput|||
|Psychrometricparameters|All|Dew/Frostpoint|
23
2022-V2
Humidity and Temperature Transmitters
## HF1 series
HygroFlex1 is the low-cost series of HVAC transmitters for relative humidity and temperature. The devices are equipped with the tried-and-tested Hygromer[®] IN-1 sensor and boast unbeatable value for money. The freely available Rotronic HW5 software enables you to change the output scaling, calibrate the transmitter and adjust the humidity sensor.
## **FEATURES**
- Accuracy: ±2 %rh, ±0.3 K, at 23 °C ±5 K
- Range of application: -20…60 °C / 0...100 %rh
- Small size
- Easy mechanical installation
- USB service interface
- Adjusted at 35 %rh / 80 %rh
## **Power supply**
- Low voltage: 2 x 2- or 3-wire
## **Signal outputs**
- Current output
- Voltage output
## **Versions**
- Space mount version with integrated probe
- Duct version (D & F)
- Wall version (W)
## **Output parameters**
- Humidity & temperature
## **Output scaling**
- Relative humidity: range selectable, standard 0…100 %rh
- Temperature: range selectable, standard: 0…50 °C
## **Display**
- Display with or without backlight
- Without display
24
2022-V2
Humidity and Temperature Transmitters
## HF1 wall and duct versions
## **APPLICATIONS**
Measures relative humidity and temperature in HVAC applications.
## **2 or 2x2-wire**
**Order code HF120** Output signal 4…20 mA Supply voltage 10...28 VDC Display Optional (without backlight) Temperature range Scalable Probes Not interchangeable Standard, duct probe 100 mm (optional, duct probe 300 mm) Filter type Polyethylene **3-wire Order code HF13x** Output signal 0…10 V 4…20 mA Only voltage output can be changed Supply voltage 15…40 VDC / 12…28 VAC Display Optional (without backlight) Temperature range Scalable il Wall version Probes Not interchangeable Standard, duct probe 100 mm 105 (optional, duct probe 300 mm) ~~h~~ Filter type Polyethylene ~~n~~ 15 15 17 32 Duct version 105 134 32 102 / 302 38 ~~=~~ **Compatible Recommended accessories** • HW5 • USB service cable AC0003
Duct version 105 134 32 102 / 302 38 ~~=~~
- Calibration device
- ER-15
## **Delivery package**
- Mounting flange AC5005
- Factory adjustment certificate
- Short instruction manual
25
2022-V2
Humidity and Temperature Transmitters ~~ET~~
## HF1 space mount version
## **APPLICATIONS**
Offices or rooms where good looks are important.
## **2 or 2x2-wire**
|**Order code**|**HF120**|
|---|---|
|Output signal|4…20 mA|
|Supplyvoltage|10...28 VDC|
|Display|Optional(without backlight)|
|**3-wire**||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Order code**<br>Output signal<br>Supplyvoltage<br>Display<br>~~7~~|**HF13x**<br>0…1 V / 0…5 V / 0…10 V / 4…20 mA<br>Onlyvoltage output can be changed<br>15…40 VDC/12…28 VAC<br>Optional(with backlight)|86<br>86<br>86<br>~~es~~<br>~~ee~~|||||||||||||||||||24|
||||
|---|---|---|
|**Technical data**|**HF1**<br>**Analog 2-wire**|**HF1**<br>**Analog 3-wire**|
|**General**|||
|Parameters|Humidityand temperature||
|Housingmaterial/IPprotection|ABS/IP65,except type S IP20||
|Dimensions|105 x 172 x 32 mm(type W),105 x 87 x 134(334)mm(type D),86 x 86 x 24 mm(type S)||
|Weight|140g||
|Probe connection|Fixed||
|Filter material|Polyethylene||
|Display|LCD, 1 or 2 decimals,<br>without backlight|LCD, 1 or 2 decimals,<br>with backlight|
|Electrical connections|Connections: screw terminals inside (type D/W)<br>Cablegland: M12||
|Power supply|10...28 VDC|15…40 VDC/12…28 VAC|
|Current consumption|2x20 mA max.|<55 mA (current output)<br><15 mA(voltage output)|
|Range of application|-20...50 °C/0...100 %rh(non-condensing)||
|Service interface|USB-Mini||
|CE/EMC compatibility|EMC Directive 2014/30/EU||
|**Humidity measurement**|||
|Sensor|ROTRONIC HYGROMER®IN-1||
|Measurement range|0…100 %rh||
|Accuracyat 23°C ±5 K|±3.0 %rh(10...90 %rh)||
|Long-term stability|<1.5 %rh/year||
|Response time|<30 st63(63 % increase 35…80 %rh)without filter||
|Maximum wind velocity|20 m/s with filter||
|**Temperature measurement**|||
|Sensor|NTC||
|Measurement range|-20...50 °C/0...100 °F||
|Accuracyat 23°C ±5 K|±0.3 K(type W,type D),±1 K(type S)||
|Response time|4 s||
|**Analog output**|||
|Number|2||
|Current|4…20 mA|4...20 mA|
|Voltage|N/A|0…1/5/10 V|
26
2022-V2
Humidity and Temperature Transmitters ~~EST~~
## HF3 series
The HygroFlex3 series is ideal for rooms where exact measurement of humidity and temperature is important. The transmitters can be used in a wide range of industries for HVAC applications, greenhouses, museums, storage rooms, libraries, swimming pools or for climate control in office buildings.
## **FEATURES**
- Accuracy: ±2 %rh, ±0.3 K at 23 °C ±5 K
- Temperature limit at probe: -40…60 °C / 0…100 %rh
- Range of application electronics: -40…60 °C / 0…100 %rh
- -10…60 °C with display
- Service interface
- Adjusted at 23 °C and 35, 80 %rh
## **Power supply**
- Low voltage: 2 x 2- or 3-wire
## **Signal outputs**
- Current output
- Voltage output
## **Versions**
- Space mount version with integrated probe
- Space mount version with fixed probe, retractable
- Wall mount (W)
- Duct mount (D)
## **Output parameters**
- Humidity & temperature *
## **Output scaling**
- Relative humidity: range selectable, standard 0…100 %rh
- Temperature: range selectable, standard: 0…50 °C
- Dew point: range selectable
## **Display**
- Display with or without backlight
- Without display
- Only scalable together with HW5 Software
27
2022-V2
Humidity and Temperature Transmitters
## HF3 space mount version
## **APPLICATIONS**
Offices or rooms where good looks are important.
## **2 or 2x2-wire**
|**Order code**|**HF320 Type S**|**HF320 Type R**|
|---|---|---|
|Output signal|4…20 mA||
|Supplyvoltage|10...28 VDC||
|Display|Optional<br>(without backlight)||
|Temperature range|Scalable*||
|Probes|Fixed internal|Retractable|
## **3-wire**
|**Order code**|**HF33x Type S**|**HF33x Type R**|
|---|---|---|
|Output signal|0…1 V<br>0…5 V<br>0…10 V<br>0…20 mA<br>4…20 mA<br>Customer selectionpossible*||
|Supplyvoltage|18…40 VDC/13…28 VAC||
|Display|Optional(with backlight)||
|py<br>Temperature range|pg<br>Scalable*||
|Probes|Fixed internal|Retractable|
**==> picture [23 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type R<br>**----- End of picture text -----**<br>
**==> picture [143 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type S<br>ee 82 82<br>82<br>27<br>**----- End of picture text -----**<br>
## **Compatible**
## **Recommended accessories**
- HW5
- Service cable AC3006 / AC3009*
## **Delivery package**
- Factory adjustment certificate
- Short instruction manual
- Requires optional HW5 software and service cable
28
2022-V2
Humidity and Temperature Transmitters
## HF3 wall and duct versions
## **APPLICATIONS**
Heating, ventilation, air-conditioning.
## **2 or 2x2-wire**
|**Order code**|**HF320 Type S**|
|---|---|
|Output signal|4…20 mA|
|Supplyvoltage|10...28 VDC|
**3/4-wire**
**Order code HF33x Type W/D** Output signal 0…1 V 0…5 V 0…10 V 0…20 mA 4…20 mA Customer selection possible* Supply voltage 18…40 VDC / 13…28 VAC ~~| Te~~ Temperature range Scalable* Probes Fixed Filter type Polyethylene
Duct version Type D ~~=~~ Wall version Type W
## **Compatible**
## **Recommended accessories**
- HW5
## **Delivery package**
- Factory adjustment certificate
- Short instruction manual
- Service cable AC3006 / AC3009* • Replacment filter & carrier SPA-PCW-PE • Replacement filter SPA-PE • Calibration device ER-15 • Mounting flange AC5005
- Requires optional HW5 software and service cable
29
2022-V2
Humidity and Temperature Transmitters
**==> picture [513 x 556] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data HF320 HF33x<br>Analog 2-wire Analog 3-wire<br>General<br>Parameters Humidity and temperature<br>Calculated parameters Dew/Frost point<br>Housing material / IP protection ABS / IP65, except type R/S IP20<br>101 x 182 x 43 mm (type W), 103 x 82 x 278 mm (type D), 82 x 82 x 27 mm (type S),<br>Dimensions<br>120 x 82 x 27 mm (type R)<br>Weight 140 g<br>Probe material Polycarbonate<br>Probe connection Fixed, type R retractable<br>Filter material Polyethylene<br>LCD, 1 or 2 decimals, LCD, 1 or 2 decimals,<br>Display (only type R/S)<br>without backlight with backlight<br>Electrical connections Type D/W: screw terminals inside, M16 cable gland<br>Power supply 10...28 VDC 18…40 VDC / 13…28 VAC<br><60 mA DC / <150 mA AC (type W/D)<br>Current consumption 2x20 mA max.<br><100 mA DC / <250 mA AC (type R/S)<br>Application temperature / Storage conditions -40…60 °C / 0…100 %rh, -10…60 °C (with display)<br>Measurement range -40...60 °C<br>Firmware upgrade Via HW5 software<br>Service interface UART service interface (Universal Asynchronous Receiver Transmitter)<br>CE / EMC compatibility EMC Directive 2014/30/EU<br>Fire protection class Corresponds to UL94-HB<br>Humidity measurement<br>Sensor ROTRONIC HYGROMER [®] IN-1<br>Measurement range 0…100 %rh<br>Accuracy at 23°C ±5 K ±2.0 %rh / ±1.0 %rh (type R)<br>Adjustment at 23 °C 35, 80 %rh<br>Long-term stability <1 %rh/year<br>Response time <15 s t63 (63 % increase 35…80 %rh) without filter<br>Maximum wind velocity 20 m/s with filter<br>Temperature measurement<br>Sensor PT100 Class A<br>Measurement range -40…60 °C / -40…140 °F<br>Accuracy at 23°C ±5 K ±0.3 K / ±0.2 K (type R)<br>Adjustment points 1<br>Long-term stability <0.1 °C / year<br>Response time <15 s t63 (63 % increase 35…80 %rh) without filter<br>Scale limits -999…+9999 units<br>Analog output<br>Number 2<br>Current 4…20 mA 0/4…20 mA<br>Voltage N/A 0…1/5/10 V<br>≤ 2x500 Ω (current output)<br>Maximum load ≤ 2x500 Ω (current output)<br>≥ 1 k Ω /V (voltage output)<br>0.02 mA<br>Accuracy at 23 °C 0.03 mA<br>2 mV (0...1 V), 5 mV (0...10 V)<br>**----- End of picture text -----**<br>
30
2022-V2
Humidity and Temperature Transmitters
## HF4 series
The HygroFlex4 series is ideal for all applications where exact measurement of humidity and temperature is critical.
## **FEATURES**
- Accuracy: ±1 %rh, ±0.2 K, at 23 °C ±5 K
- Temperature limit at probe: -50…100 °C / 0…100 %rh
- Range of application electronics: -40…60 °C / 0…100 %rh; -10…60 °C with display
- Service interface
- Adjusted at 23 °C and 10, 35, 80 %rh
## **Power supply**
- Low voltage: 2x2 or 3-wire
## **Signal outputs**
- Current output
- Voltage output
## **Versions**
- Wall version (W)
- Duct version (D)
## **Output parameters**
- Humidity & temperature *
## **Output scaling**
- Relative humidity: range selectable, standard 0…100 %rh
- Temperature: range selectable, standard: 0...50 °C
- Dew point: range selectable
## **Display**
- Display with backlight (excl. 2-wire), trend indicators and keypad
- Without display
- Only scalable together with HW5 Software
31
2022-V2
Humidity and Temperature Transmitters
**2 or 2x2-wire**
## HF4 wall and duct versions
## **APPLICATIONS**
HVAC applications, greenhouses, museums, storage rooms, libraries, swimming pools, climate control in office buildings
**Order code HF420 Type W/D** Output signal 4…20 mA Supply voltage 10...28 VDC Display Optional (without backlight, keypad) Type D only horizontal version possible with display (see pictures) Temperature range Scalable* Probes Fixed ~~ee~~ Filter type Polyethylene |, **3-wire Order code HF43x Type W/D** Output signal 0…1 V 0…5 V 0…10 V 0…20 mA 4...20 mA Customer selection possible* Wall version, type W Supply voltage 18…40 VDC 13…28 VAC Display Optional (with backlight, keypad) Type D only horizontal version possible with display (see pictures) Temperature range Scalable* Probes Fixed Filter type Polyethylene ~~—— i~~ Duct version, type D ~~0~~ **Compatible Recommended accessories** • HW5 • Service cable AC3006 / AC3009*
- Service cable AC3006 / AC3009* • Replacement filter, PE, black NSP-PCB-PE • Calibration device ~~ER-1~~ 5 • Mounting kit DIN top-hat rail (type W) AC5002
## **Delivery package**
- Factory adjustment certificate
- Short instruction manual
- Mounting flange (type D)
- Requires optional HW5 software and service cable
32
2022-V2
Humidity and Temperature Transmitters
**==> picture [513 x 538] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data HF420 HF43x<br>Analog 2-wire Analog 3-wire<br>General<br>Parameters Humidity and temperature<br>Calculated parameters Dew/Frost point<br>Housing material / IP protection ABS / IP65<br>Dimensions 129 x 157 x 45 mm (type W), 129 x 253 x 72 mm (type D)<br>Weight 220 g<br>Probe material Polycarbonate<br>Probe connection Fixed<br>Filter material Polyethylene<br>Display LCD, 1 or 2 decimals LCD, 1 or 2 decimals<br>without backlight, with backlight,<br>menu navigation, 4 keys menu navigation, 4 keys<br>Electrical connections Screw terminals inside, M16 cable gland<br>Power supply 10...28 VDC 18…40 VDC / 13…28 VAC<br>Current consumption 2 x 20 mA max. <270 mA<br>Application temp. housing / electronics -40…60 °C / -10…60 °C (with LCD), 0…100 %rh<br>Measurement range -50...100 °C<br>Firmware upgrade Via HW5 software<br>Service interface UART service interface (Universal Asynchronous Receiver Transmitter)<br>CE / EMC compatibility EMC Directive 2014/30/EU<br>Fire protection class Corresponds to UL94-HB<br>Humidity measurement<br>Sensor ROTRONIC HYGROMER [®] IN-1<br>Measurement range 0…100 %rh<br>Accuracy at 23 °C ±5 K ±1.0 %rh<br>Adjustment at 23 °C 10, 35, 80 %rh<br>Long-term stability <1 %rh/year<br>Response time <15 s t 63 (63 % increase 35…80 %rh) without filter<br>Maximum wind velocity 20 m/s with polyethylene filter<br>Temperature measurement<br>Sensor PT100 1/3 Class B<br>Measurement range -50…100 °C / -58…212 °F<br>Accuracy at 23 °C ±5 K ±0.2 K<br>Adjustment points 1<br>Long-term stability <0.1 °C / year<br>Response time <15 s t 63 (63 % increase 35…80 %rh) without filter<br>Analog output<br>Number 2<br>Current 4…20 mA 0/4…20 mA<br>Voltage N/A 0…1/5/10 V<br>Maximum load ≤ 2x500 Ω (current output) ≤ 2x500 Ω (current output)<br>≥ 1 k Ω /V (voltage output)<br>Accuracy at 23 °C 0.03 mA 0.02 mA<br>2 mV (0...1 V), 5 mV (0...10 V)<br>**----- End of picture text -----**<br>
33
2022-V2
Humidity and Temperature Transmitters ~~—____PST_tefronk~~
## HF5 series
The HF5 series is compatible with HygroClip2 probes with integrated AirChip technology – which achieve excellent accuracy thanks to their precision. This generation of instruments includes unique calibration and adjustment functions.
## **FEATURES**
- Interchangeable HC2A / HC2 probes
- Housing material: ABS / Aluminum
- Accuracy: See chapter «Probes»
- Temperature limit at probe: See chapter «Probes»
- Range of application electronics: -40…60 °C / 0…100 %rh; -10…60 °C with display
- Digital outputs, also combinable with analog outputs
- Use as %rh / °C simulator for system validation *
- Service interface
## **Power supply**
- Low voltage: 2x2 or 3-wire
- Low voltage, galvanically isolated; 4-wire
- Mains voltage, galvanically isolated; 4-wire
## **Signal outputs**
- Current outputs, voltage outputs ~~re~~ • RS-485, USB, Ethernet
## **Versions**
• Wall mount (W), duct mount (D), cable version (C) with a selected probe ~~rs~~
**Output parameters**
- Humidity & temperature
- Humidity & a psychrometric parameter
- Temperature & psychrometric parameters
## **Output scaling**
- Relative humidity: range selectable, standard scale 0…100 %rh
- Temperature: range selectable, standard scale 0...50 °C
- Psychrometric parameters: range selectable
Available with ATEX certificate
## **Display**
- Display with backlight (excl. 2-wire), trend indicators and keypad
- Without display
* Requires optional HW5 software and service cable
34
2022-V2
Humidity and Temperature Transmitters
## HF5 wall and duct versions
## **APPLICATIONS**
HVAC applications, food and pharmaceutical industries, printing and paper industries, meteorology, agriculture, archaeology.
## **2x2-wire**
|**Order code**|**HF520 Type W/D**|
|---|---|
|Output signal|4…20 mA|
|Supplyvoltage|10...28 VDC|
## **3/4-wire**
|**Order code**|**HF5xx Type W/D**|**HF5xx Type W/D**|
|---|---|---|
|Output signal|0…1 V<br>0…5 V<br>0…10 V<br>0…20 mA<br>4...20 mA<br>Customer selectionpossible*|RS-485<br>Ethernet<br>(not for aluminum version)|
|Supply voltage|Low voltage: 15…40 VDC / 12…28 VAC<br>Galvanically isolated: 9…36 VDC / 7…24 VAC<br>(not for aluminum version)||
|Housing|ABS or aluminum||
|Display|Optional (with backlight, keypad)<br>Type D only horizontal version possible with display<br>(seepictures)||
|Output ranges|Scalable*||
|Probes|1 interchangeable HC2A/HC2probe input||
**==> picture [43 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Wall version<br>**----- End of picture text -----**<br>
## Type W (aluminum)
**==> picture [192 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
160<br>160<br>—<br>30<br>100<br>208 25<br>108<br>61<br>25 25<br>**----- End of picture text -----**<br>
248 61 160 ~~al~~ Duct version 30 Type D (aluminum)
**==> picture [47 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
Wall version<br>Type W (ABS)<br>180<br>108<br>**----- End of picture text -----**<br>
**==> picture [47 x 71] intentionally omitted <==**
**----- Start of picture text -----**<br>
233<br>108<br>Duct version<br>Type D (ABS)<br>**----- End of picture text -----**<br>
* Requires optional HW5 software and service cable
35
2022-V2
Humidity and Temperature Transmitters
## HF5 wall versions
## **4-wire mains voltage**
|**Order code**|**HF5xx Type W/D**|**HF5xx Type W/D**|
|---|---|---|
|Output signal|0…1 V<br>0…5 V<br>0…10 V<br>0…20 mA<br>4...20 mA<br>Customer selectionpossible*|RS-485<br>Ethernet|
|Supplyvoltage|Mains voltage: 100...240 VAC||
|Versions|Type W||
|Display|Optional(with backlight,keypad)||
|Probes|1 interchangeable HC2A/HC2probe input||
|Output ranges|Scalable*||
|Housing|ABS||
Wall version type W
**==> picture [19 x 41] intentionally omitted <==**
**----- Start of picture text -----**<br>
210<br>08<br>1<br>**----- End of picture text -----**<br>
## **Compatible**
## **Recommended accessories**
- All HC2A / HC2 probes (order separately)
- HW5
## **Delivery package**
- Standard climate probe HC2A-S • Probe extension cable 2 m E2-02A • Service cable AC3006* • Mounting kit DIN top-hat rail (type W) AC5002 • Calibration cable with HP23 AC2001
- Product qualification
- Short instruction manual
- Mounting flange (type D)
- Requires optional HW5 software and service cable
36
2022-V2
Humidity and Temperature Transmitters
**==> picture [513 x 510] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data HF520 HF53/4/x HF56x, mains voltage 4-wire<br>2-wire 3-wire<br>General<br>Parameters Humidity and temperature<br>Calculated parameters All psychrometric parameters<br>Housing material / IP protection ABS / IP65 (models with USB or Ethernet interface, IP40), Al/IP65 (also with Ethernet interface)<br>Dimensions ABS: 129 x 72 x 45 mm (type D/W) 192 x 102 x 52 mm (type D/W)<br>Al: 160 x 100 x 61 mm<br>Weight ABS: 220 g ABS: 220 g, Al: 750 g ABS: 500 g<br>Probe connection / Interface E2 (threaded coupling) / UART<br>Display LCD, 1 or 2 decimals, without LCD, 1 or 2 decimals, with backlight,<br>backlight, menu navigation, 4 Menu navigation, 4 keys<br>keys<br>Electrical connections Screw terminals inside 2xM16<br>M16 cable gland Cable gland<br>Socket (USB/Ethernet)<br>Power supply 10...28 VDC 15…40 VDC/12…28 VDC 100…240 VAC<br>min 10 + 0.02 x load galvanically. isolated<br>9…36 VDC / 7…24 VAC<br>Current consumption 2 x 20 mA max. 270 mA max. (without Ethernet) 30 mA max. (without Ethernet)<br>420 mA max. (with Ethernet) 45 mA max. (with Ethernet)<br>Start-up time 1 min<br>Application temp. housing / -40...60 °C / -10...60 °C (with display), 0...100 %rh<br>electronics<br>Firmware upgrade Via HW5 software<br>Service interface UART service interface (Universal Asynchronous Receiver Transmitter)<br>CE / EMC compatibility EMC Directive 2014/30/EU<br>Fire protection class Corresponds to UL94-HB<br>Humidity measurement<br>Humidity measurement Probe dependent<br>Temperature measurement<br>Temperature measurement Probe dependent<br>Analog output<br>Number 2<br>Current 4…20 mA 0/4…20 mA<br>Voltage N/A 0…1/5/10 V<br>Galvanic isolation N/A HF54 and HF56<br>Maximum load 2x500 Ω ≤ 2x500 Ω (current output)<br>≥ 1 k Ω /V (voltage output)<br>Accuracy at 23 °C 0.02 mA 0.02 mA<br>10 mV<br>Digital output<br>RS-485 No digital outputs RS-485 & analog<br>USB USB & RS-485 & analog<br>Ethernet Ethernet RJ45 & RS-485 & analog<br>**----- End of picture text -----**<br>
37
2022-V2
Humidity and Temperature Transmitters
## HF73A series
The HygroFlex HF73A transmitters are used wherever harsh environments demand an optimal solution. There is hardly an industrial process in which humidity, temperature or dew point / frost point does not need to be considered.
## **FEATURES**
- Accuracy: ±1.0 %rh, ±0.2 K, at 10...30 °C
- Temperature limit at probe: max. -100…200 °C[1] 0…100 %rh
- Range of application electronics: -40...85 °C / 0…100 %rh
- Aluminum diecast housing and probe of PPS
- Various probe lengths available
- Use as a %rh/°C simulator for system validation *
- Service interface
- Adjusted at 23 °C and 10, 35, 80 %rh
## **Power supply**
- Low voltage: 2x2 or 3-wire
## **Signal outputs**
- Current outputs, voltage outputs*
## **Versions**
- Duct version (D)
## **Output parameters**
- Humidity & temperature*
## **Output scaling**
- Relative humidity: range selectable, standard scale 0…100 %rh
- Temperature: range selectable, standard: -50…100 °C
- Dew/Frost point: range selectable
## **Display**
- Without display
- Requires optional HW5 software and service cable
- 1 Short-term peak load (3 x 5 min)
38
2022-V2
Humidity and Temperature Transmitters
## HF73A version
## **APPLICATIONS**
Measures relative humidity, temperature and dew/frost point in industrial environments and outdoors. For use in harsh conditions.
## **3-wire**
|**Order code**|**HF732A**|
|---|---|
|Output signal|0…1 V<br>0…5 V<br>0…10 V<br>0…20 mA<br>4...20 mA<br>Customer selectionpossible*|
|Supplyvoltage|18…40 VDC/13…28 VAC|
|Probes|Fixed,PPS|
|Display|No|
|Output ranges|Scalable*|
|Temperature limit atprobe|-100…150 °C(type D)**|
|Filter carrier|Slotted sleeve(order filter separately)|
**==> picture [79 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
280<br>Duct version<br>Type D<br>**----- End of picture text -----**<br>
> * Requires optional HW5 software and service cable
> ** Peak load: For 100 hours between 190 °C and 200 °C. Maximal permissible continuous load: 190°C.
39
2022-V2
Humidity and Temperature Transmitters
**==> picture [513 x 506] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data HF73A, analog, 3-wire<br>General<br>Parameters Humidity and temperature<br>Calculated parameters Dew/Frost point<br>Housing material / IP protection Aluminum / IP65<br>Dimensions 60 x 100 x 100 (type D)<br>Weight 600 g + 140 g per probe extension unit (150 mm)<br>Probe material PPS<br>Probe connection Fixed<br>Filter carrier Slotted sleeve<br>Filter material Filter is not supplied with transmitter (must be ordered separately)<br>Display No<br>Electrical connections Screw terminals inside, M16 cable gland<br>Power supply 15…40 VDC / 13…28 VAC<br>Current consumption 150 mA max.<br>Application temp. housing / electronics -40…85 °C, 0…100 %rh<br>Measurement range -100…150 °C (type D)<br>Firmware upgrade Via HW5 software<br>Service interface UART service interface (Universal Asynchronous Receiver Transmitter)<br>CE / EMC compatibility EMC Directive 2014/30/EU<br>Humidity measurement<br>Sensor ROTRONIC HYGROMER [®] HT-1<br>Measurement range 0…100 %rh<br>Accuracy at 10...30 °C ±1.0 %rh<br>Adjustment at 23 °C 10, 35, 80 %rh<br>Long-term stability <1 %rh/year<br>Response time <15 s t 63 (63 % increase 35…80 %rh) without filter<br>Temperature measurement<br>Sensor PT100 Class A<br>Peak load: For 100 hours between 190 °C and 200 °C.<br>Measurement range<br>Maximal permissible continuous load: 190°C<br>Accuracy at 10...30 °C ±0.2 K<br>Adjustment points 1<br>Long-term stability <0.1 °C / year<br>Response time <15 s t 63 (63 % increase 35…80 %rh) without filter<br>Analog output<br>Number 2<br>Current 0/4…20 mA<br>Voltage 0…1/5/10 V<br>≤ 2x500 Ω (current output)<br>Maximum load<br>≥ 1 k Ω /V (voltage output)<br>0.02 mA<br>Accuracy at 23 °C<br>2 mV (0...1 V), 5 mV (0...10 V)<br>**----- End of picture text -----**<br>
40
2022-V2
Humidity and Temperature Transmitters
## XB32A-OEM
The XB OEM transmitter consists of a cable PPS probe, a printed circuit board without housing. Thanks to its compact size, high accuracy and choice of analog outputs, the transmitter can be adapted to meet customer requirements and used practically everywhere.
## **APPLICATIONS**
Climate chambers, incubators, monitoring of industrial processes, etc.
## **FEATURES**
- Accuracy: ±1.0 %rh, ±0.2 K, at 10...30 °C
- Range of application: probe dependent up to 0...100 %rh / -100 to 200 °C[1]
- Range of application: electronics -40…85 °C
- Freely scalable analog outputs
- Simulator mode*
## **Power supply**
- Low voltage 3/4 wire (XB3X)
||90.05|90.05|90.05||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||81.5<br>77.5|||Ad|||56||58|64<br>|||
|**U-**|**U+**|**GND**<br>**GND**|**OUT2**|**OUT1**|||||||||
## **Signal outputs**
- Current outputs, voltage outputs
PPS probe Ø15 mm
## **Versions**
- Printed circuit board with cable probe (C)
## **Probes**
- PPS probes
- Probe diameter: 15 mm
- Probe length up to 294 mm
- Cable lengths 2 and 5 m
## **Output parameters**
- Humidity & temperature
- Dew or frost point & temperature or humidity
## **Compatible**
## **Recommended accessories**
- HW5
## **Delivery package**
- Wire mesh (SPA-WM), sinter steel (SPA-SSS) and Teflon (SPA-PFTE) filters
- Service cable AC3006 / AC3009*
- Factory adjustment certificate
- Short instruction manual
- Note: a filter must be ordered separately
- Requires optional HW5 software and service cable
- 1 Short-term peak load (3 x 5 min)
41
2022-V2
Humidity and Temperature Data loggers
## Overview
||**Basic**||**Compact**|
|---|---|---|---|
||He:|im|io|
||**HL-1D**|**BL-1D**|**HL-20D**|
|Memory capacity|32,000 lines (each line contains<br>%rh + °C)|32’000 lines|32,000 lines|
|Sensor|HYGROMER IN-1 / NTC|BOSCH BMP280 /<br>HYGROMER IN-1/NTC|HYGROMER IN-1 / PT100 Class A|
|Range of application|-30...70 °C<br>0...100 %rh|-30...70 °C<br>0...100 %rh|-10…60 °C<br>0...100 %rh|
|Calculations|–|–|Dew/Frostpoint|
|Power supply|1x CR2 battery|1 x CR2 battery|3x AA batteries|
|Configurable logginginterval|Yes|||
|Programmable alarms|Yes|||
|Interface|USB|USB|UART, requires AC3006<br>service cable|
|IPprotection|IP67|IP67|IP40|
|Standards|EN 12830|EN12830|–|
|CE/EMC compatibility|Yes|||
42
2022-V2
Humidity and Temperature Data loggers
## HygroLog HL-1D
## **Basic logger**
The HL-1D is the smallest humidity logger available from Rotronic. It offers the most important logging functions and is fully compatible with HW5 software.
## **FEATURES**
- Accuracy: ±2.0 %rh, ±0.3 K
- Compact with very high level of IP protection
- High storage capacity: 32,000 lines
- Free evaluation and configuration software HW5
- Very long battery life: up to 3 years
- Conforms to EN12830. Version V3.0 and later
- Programmable logging mode
|**Technical data**|**HL-1D**|
|---|---|
|**General**||
|Parameters|Humidity& temperature|
|Sensor type|HYGROMER®IN-1/NTC|
|Accuracyat 23 °C ±5 K|±2.0 %rh,±0.3 K|
|Range of application /<br>Storage conditions|-30…70 °C / 0…100 %rh|
|IPprotection|IP67|
|Weight|85g|
|Dimensions|90 x 60 x 23 mm|
|Logginginterval|30 s…24 h|
|Battery|1 x CR2|
|Batterylife|Upto 3years(logginginterval 1 h)|
|Batterycharge indicator|Yes(HW5 software,displayand LED indicator)|
|Storage capacity|32,000 lines(each line contain %rh & °C)|
|Function|MIN/MAX/AVG|
|Display|LCD|
|Resolution|0.1 %rh,0.1 °C|
|Displayrefresh rate|5 s(standard)or same as logginginterval|
|LED indicators|2 LEDs|
||Right LED flashesgreen duringdata logging|
||Left LED flashes red when limits exceeded<br>or low batterystate|
|Communication|USB-Miniport(cable optional)|
|Standards|EN12830(V3.0 and later)|
USB-Mini port Battery (settings and compartment data download)
## **Configuration & evaluation**
The values stored in the HL1D can be downloaded with the HW5 software and display ed graphically. The user determines the logging interval, the alarm limits, the recording mode and much more.
**==> picture [162 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
a<br>60<br>90 23<br>**----- End of picture text -----**<br>
## **Delivery package**
## **Recommended accessories**
- Battery, CR2
- USB-Mini cable AC0003
- Short instruction manual
- Function and calibration certificate
43
2022-V2
Humidity and Temperature Data loggers
## BL-1D
In addition to humidity and temperature, the BL-1D also logs ambient pressure and dew point. Thanks to its full HW5 functionality, its compact size and easy handling, the BL-1D is ideal for numerous applications.
## **FEATURES**
- Accuracy: ±3.0 hPa, ±2.0 %rh, ±0.3 K
- Compact with very high level of IP protection
- High storage capacity: 32,000 lines
- Free evaluation and configuration software HW5
- Very long battery life: up to 3 years
- Conforms to EN12830
|**Technical data**|**BL-1D**|
|---|---|
|**General**||
|Parameters|Pressure/Humidity /Temperature|
|Sensor type|BOSCH BMP280/HYGROMER®IN-1/NTC|
|Accuracyat 23 °C ±5 K|±3.0 hPa,±2.0 %rh,±0.3 K|
|Range of application /<br>Storage conditions|-30..70 °C / 0..100 %rh|
|IPprotection|IP67|
|Weight|85g|
|Dimensions|90 x 60 x 23 mm|
|Logginginterval|30 s…24 h|
|Battery|1 x CR2|
|Batterylife|Upto 3years(logginginterval 1 h)|
|Batterycharge indicator|Yes(HW5 software,displayand LED indicator)|
|Storage capacity|32,000 lines(each line contains °C/%rh/Pa/DP)|
|Function|MIN/MAX/AVG|
|Display|LCD|
|Resolution|1 hPa,0.1 %rh,0.1 °C|
|Displayrefresh rate|5 s(standard)or same as logginginterval|
|Communication|USB-Miniport(cable optional)|
|Standards|EN 12830|
## **Configuration & evaluation**
The values stored in the BL-1D can be downloaded with the HW5 software and displayed graphically. The user determines the logging interval, the alarm limits, the recording mode and much more.
~~-—______-|~~ |[—][|] 60 90 23
## **Delivery package**
## **Recommended accessories**
- Battery, CR2
- USB-Mini cable
**==> picture [29 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
AC0003<br>**----- End of picture text -----**<br>
- Short instruction manual
- Function and calibration certificate
44
2022-V2
Humidity and Temperature Data loggers
## HygroLog HL-20D
## **Precision compact logger**
The compact data logger for humidity and temperature measurement offers high precision and reliability at a reasonable price. The HL-20 series is easy to use and suitable for a wide range of applications. Thanks to its integrated batteries, the HL-20D provides hours of operation and offers its users maximum flexibility.
## **APPLICATIONS**
Warehouses, factories, museums, office buildings, cleanrooms, transportation, libraries and test facilities.
## **FEATURES**
- Range of application: -10…60 °C / 0…100 %rh
- 20,000 data point memory
**==> picture [136 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
HL-20-D HL-20D-SET<br>**----- End of picture text -----**<br>
- Accuracy at 10...30 °C: ±1.3 %rh (0…10 %rh) / ±0.8 %rh (10…60 %rh) /
- ±1.3 %rh (60…100 %rh) ±0.3 K
- Freely selectable logging interval, 5 s…1 h
- Integrated clock with time stamp for every measurement
- Adjusted at 10, 35, 80 %rh and 23 °C
- Programmable visual alarms
- Free HW5 software for device configuration and analysing recorded data
|**Order code**|**Display**|**Incl. AC3006 service cable**|
|---|---|---|
|HL-20D|Yes|No|
|HL-20D-SET1|Yes|Yes|
## **Delivery package**
## **Recommended accessories**
- Factory adjustment certificate, short instruction manual, 3 AA batteries
- Screw with plug for wall mounting
• Service cable AC3006 • Calibration device HL-20-CAL • Humidity standard for calibration 10 %rh EA10-SCS • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS
45
2022-V2
Humidity and Temperature Handheld instruments
## HygroPalm HP31
The HygroPalm HP31 is a handheld instrument with a fix Rotronic probe, it is able to perform spot measurements and logging of relative humidity, temperature and psychrometric parameters.
## **APPLICATIONS**
Field inspection and spot checks in HVAC, pharmaceutical industry, agriculture and food industry and building management systems.
## **FEATURES**
- Measures relative humidity and temperature and perform psychometric calculations
- Visual and audible alarms
- Graphic display for saved data
- 64’000 data points memory with programmable logging interval
- Long-life rechargeable battery (up to 48 hours at a logging interval of 30 seconds)
## **General specifications**
|**General specificationspecificationsecifications**|**General specificationspecificationsecifications**|
|---|---|
|Order code|HP31|
|Device type|Handheld device(%rh/°C)|
|Application range|-10…60 °C|0…100 %rh(non-cond.)|
|Storage range|-10…45 °C|10…90 %rh|
|Probe application range|-10…60 °C|0…100 %rh(non-cond.)|
|Functions|Spot measurements<br>Programmable logging interval<br>MIN/MAX/AVG|
|Accuracy @23°C|±2 %rh/±0.3 °C|
|Logginginterval|1 s…24 h|
|Memorycapacity|8 x 8000 datapoints|
|Psychrometric calculations|Dew / Frost point (Dp / Fp)<br>Wet bulb temperature (Tw)<br>Enthalpy (H)<br>Vapor concentration (Dv)<br>Specific humidity (Q)<br>Mixing ratio by weight (R)<br>Vapor pressure (E)<br>Saturation vapor pressure (Ew)<br>Saturation vapor density (SVD)|
|Calculation method|WMO Standard|
|Displayrefresh rate|1 s(typical)|
|Integrated battery|Lithium polymer, 3.7 V, 1000 mAh<br>48 h – Logging every 30 s, screen off<br>10 h – Screen always on|
|PC interface|Micro-USBport,HW5 compatible|
|**Housing / Mechanics**||
|Enclosure material|ABS,TPR|
|IPprotection class|IP65|
|Dimensions|160 x 63 x 30 mm|
|Weight|185g|
## **Compatible**
## **Recommended accessories**
- HW5
## **Delivery package**
- Humidity standard for calibration 10 %rh
- Humidity standard for calibration 35 %rh
- Humidity standard for calibration 80 %rh
EA10-SCS EA35-SCS EA80-SCS
- HygroPalm HP31
- Soft case
- Micro-USB service cable AC0006
46
2022-V2
Humidity and Temperature Handheld instruments
## HygroPalm HP32
The HygroPalm HP32 can be combined without adjustment with all all HC2 and HC2A probes (except HC2-LDP). It measures relative humidity and temperature, can perform all psychrometric calculations and has trend indicators as well as a hold function to freeze measured values.
## **APPLICATIONS**
Field inspection and spot checks in HVAC, pharmaceutical industry, agriculture and food industry and building management systems.
65.2 ~~A~~
## **FEATURES**
- Measures relative humidity and temperature and perform psychometric calculations
- Visual and audible alarms
- Graphic display for saved data
- 64’000 data points memory with programmable logging interval
- Long-life rechargeable battery (up to 48 hours at a logging interval of 30 seconds)
**==> picture [511 x 538] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|General specifications|65.2|
|Order code|HP32|
|Device type|Handheld device (%rh / °C)|
|Application range|-10…60 °C | 0…100 %rh (non-cond.)|
|Storage range|-10…45 °C | 10…90 %rh|
|Probe application range|Depends on probe|
|Functions|Spot measurements|
|Programmable logging interval|
|MIN / MAX / AVG|
|Accuracy|@ 23°C|Depends on probe|
|Logging interval|1 s…24 h|
|Memory capacity|8 x 8000 data points|
|Psychrometric calculations|Dew / Frost point (Dp / Fp)|
|Wet bulb temperature (Tw)|
|Enthalpy (H)|
|Vapor concentration (Dv)|
|Specific humidity (Q)|
|Mixing ratio by weight (R)|
|Vapor pressure (E)|
|Saturation vapor pressure (Ew)|
|Saturation vapor density|(SVD)|
|Calculation method|WMO Standard|
|Display refresh rate|1 s (typical)|
|Integrated battery|Lithium polymer, 3.7 V, 1000 mAh|
|48 h – Logging every 30 s, screen off|
|10 h – Screen always on|
|PC interface|Micro-USB port, HW5 compatible|
|Housing|/ Mechanics|
|Enclosure material|ABS, TPR|
|IP protection class|IP65|
|Dimensions|160 x 63 x 30 mm|
|Weight|185 g|
|Compatible|Recommended accessories|
|• All HC2 and HC2A probes (except HC2-LDP)|• Humidity standard for calibration 10 %rh|EA10-SCS|
|• Humidity standard for calibration 35 %rh|EA35-SCS|
|Delivery|package|• Humidity standard for calibration 80 %rh|EA80-SCS|
|• HygroPalm HP32|
|• Short instruction manual|
|• Soft case|
|• USB-Micro service cable AC0006|
|ee|
|47|
|2022-V2|
**----- End of picture text -----**<br>
Humidity and Temperature Handheld instruments
**==> picture [513 x 474] intentionally omitted <==**
**----- Start of picture text -----**<br>
Specifications handheld instruments<br>Features HP31 HP32<br>Probe type Fixed probe HC2A-xx<br>(not included)<br>Probe interchangeable No Yes<br>Humidity / Temperature sensor HYGROMER [®] IN-1 Probe dependent<br>Pt100 1/3 Class B<br>Number of probe inputs N/A 1<br>Measurement range (probe) -10…60 °C Probe dependent<br>0…100 %rh<br>Accuracy at 10...30 °C ±2 %rh / ±0.3 K Probe dependent<br>Long-term stability <1 %rh / year<br>Response time humidity sensor <15 s τ 63 Probe dependent<br>Initialization time <2 s<br>Range of application -10…60 °C / 0…100 %rh<br>Display resolution 2 decimals<br>Illuminated display Yes<br>Alarm indicators Yes<br>Battery indicator Yes<br>Real time clock Yes<br>Functions<br>Adjustment of transmitters No<br>Adjustment via keypad Single & multi-point %rh<br>Single-point °C<br>Probe adjustment with dew point reference No<br>Calculations All psychrometric parameters<br>Data logging 8 x 8,000 measurement points<br>Electrical specifications<br>Power supply Integrated rechargeable battery<br>Rechargeable battery charge No<br>Battery life (typical, without backlight) 4...7 h<br>Communication interfaces Micro USB<br>Service cable AC0006<br>Max. length probe cable 5 m<br>Mechanical specifications<br>Housing material ABS, TPR (housing)<br>Dimensions 250 x 65 x 31 mm 150 x 65 x 31 mm<br>(without probe)<br>Weight 200 g 185 g<br>CE / EMC directives 2014/30/EU<br>IP protection class IP65<br>**----- End of picture text -----**<br>
48
2022-V2
Humidity and Temperature Handheld instruments
## HygroPalm HP-GTS – Measuring instrument for the paper industry
The HygroPalm HP-GTS from Rotronic is a tried-and-tested instrument for measurement of equilibrium relative humidity and temperature in stacks of paper and cardboard.
## **APPLICATIONS**
Humidity measurements in stacks of paper, cardboard and textiles for paper and textile technicians and printers.
## **FEATURES**
- Measures relative humidity and temperature in stacks of paper
- Graphical display of measured values
- Freely adjustable visual and audible alarm
- 64,000 data point memory with programmable logging interval
|**General specifications**|**General specifications**|
|---|---|
|Order code|HP-GTS|
|Device type|Handheld device(%rh/°C)|
|Range of application of instrument<br>andprobe|-10…60 °C / 0…100 %rh (non-condensing)|
|Humiditysensor|ROTRONIC HYGROMER IN-1|
|Accuracy @23 °C|±2 %rh/±0.3 °K|
|Functions|Spot measurements<br>Programmable logging interval<br>MIN/MAX/AVG|
|Logginginterval|1 s…24 h|
|Memorycapacity|8 x 8000 datapoints|
|Displayrefresh rate|1 s(typical)|
|PC interface|Micro-USBport,HW5 compatible V|
|Integrated battery|• Rechargeable lithium polymer battery<br>• 3.7 V<br>• 1000 mAh<br>• 48 h with screen off, logging every 30 s<br>• 10 h with screen always on|
|**Housing / Mechanics**||
|Housingmaterial|ABS,TPR|
|Probe material|Aluminum|
|IPprotection class|IP65(measuringinstrument)|
|Dimensions<br>Weiht|408 x 63 x 30 mm<br>225|
- **Delivery package Recommended accessories** • HygroPalm HP-GTS • Calibration device for sword probes EGS • Soft case • Humidity standard for calibration 10 %rh EA10-SCS • Micro-USB cable (computer connection and battery charging) • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS
- ~~OB~~ 49
- 2022-V2
Humidity and Temperature Calibration
## HygroGen2 HG2
Since its launch, the Rotronic HygroGen has defined the standard for portable humidity and temperature calibration. Hundreds of users worldwide have identified that this tool for the rapid generation of stable temperature and humidity conditions can save significant amounts of time in performing calibrations of all types of humidity instruments from all manufacturers.
The HygroGen2 further satisfies the stringent demands of quality and compliance regulations with its ability to calibrate instruments over their full working range, and is embraced throughout the pharmaceutical industry as the leading instrument in its class and is favored in ISO 17025 humidity calibration laboratories across the world.
HygroGen2 with external chilled mirror hygrometer – Michell S8000 Remote
Being portable and robust, it can be set up at the installation location allowing for complete system qualification. The rock-solid stability, minimal thermal gradients and quick set-point changes of HygroGen2-S are now replicated in a new family member: HygroGen2-XL, which boasts a chamber with 10 times the capacity.
## **External Chilled Mirror Reference Integration**
(formerly “AutoCal+”) External chilled mirror Reference Integration further extends the utility of the generator, with the ability to integrate chilled mirror hygrometers as the AutoCal calibration reference or within the Remote API.
## **APPLICATIONS**
On-site calibration solution for all users of humidity and temperature measuring equipment.
## **FEATURES**
- Generates stable humidity and temperature conditions (<±0.1 %rh, <±0.01 °C)
- Calibration solution for the laboratory and on-site
- Humidity equilibrium typically in only 5 minutes for HG2-S, 15 minutes for HG2-XL
- Calibrates multiple probes simultaneously
HG2-S and HG2-XL in comparison
- «AutoCal» automatic calibration (optional)
- «Remote API» logging and control with third-party software (optional)
## Video HygroGen2
**==> picture [122 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Interested? Then scan the QR code!<br>**----- End of picture text -----**<br>
## **Delivery package**
## **Recommended accessories**
- Instruction manual
- SCS certificate for reference probe
- See HygroGen2 accessories
- «AutoCal» automatic calibration
- Extended ranges of application «HumiExt» and «TempExt»
- «ExtRef» chilled mirror reference
- «RemoteSS» remote screen sharing
- «RemoteAPI» programming interface for remote control
50
2022-V2
Humidity and Temperature Calibration
**==> picture [512 x 385] intentionally omitted <==**
**----- Start of picture text -----**<br>
HygroGen2 Specifications HG2-S HG2-XL<br>Chamber volume 2 liters 20 liters<br>Working volume 1.5 liters 17 liters<br>Humidity changes (<±0.1 %rh stability) 5…95 %rh < 5 minutes < 15 minutes<br>Temperature changes (<±0.01 °C stability) 23...50 °C < 5 minutes < 15 minutes<br>23...0 °C < 25 minutes < 35 minutes<br>Temperature gradients 15...50 °C < ± 0.05 °C < ± 0.05 °C<br>5...60 °C < ± 0.1 °C < ± 0.1 °C<br>0...5 °C < ± 0.15 °C < ± 0.15 °C<br>Probe mounting Up to 6 probes through 8 probes through the door,<br>door ports plus internal shelf racks<br>Weight & dimensions 13 kg, 45 x 41x 21 cm 37 kg, 80 x 62 x 41 cm<br>Working principle Mixed flow with desiccant dryer cell and piezoelectric humidifier;<br>Peltier thermoelectric element with radial chamber mixing fan<br>Control probe specification ± 0.8 %rh (10…30 °C), ± 2 %rh (0…60 °C) ± 0.1 K (10…30 °C), ± 0.3 K (0…60 °C)<br>Typical calibration uncertainty ± 1.5 %rh (k=2) at 23 °C, ± 0.15°C (k=2) 15...50 °C<br>Sensor HygroClip2, capacitive RH sensor, Pt100 temperature sensor<br>Control type Embedded multiple PID controller, touch screen graphical user interface<br>Programmer function 20 user programs can be saved, up to 200 set-points per program can be changed<br>External sample loop for MBW reference Temperature controlled outlet and inlet, 6 mm fittings<br>USB ports 7 front, 2 rear<br>Integrated software Rotronic HW5<br>Water level Low and high alarm, bar graph status indication<br>Water quality UV sterilization, auto time cycling<br>Desiccant condition Condition monitored during control operation<br>Optional enhanced features Temperature and humidity range extensions, AutoCal, External MBW/RHS<br>Reference Integration, Remote Screen Share, Remote API<br>Power supply 110...240 VAC 50/60 Hz, 3 A (240 VAC) 6A (110 VAC)<br>Housing Powder coated aluminum and steel, IP20<br>Operating conditions 10-35 °C, <2000 m altitude<br>CE Safety: EN 61010-1:2001<br>EMC: EN 61326-1:2006<br>EN 61000-6-1:2007<br>**----- End of picture text -----**<br>
**==> picture [513 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
Order code Description<br>HG2-S HygroGen2 with touch screen, calibrated control/reference probe, set-point control & programmer function,<br>heated sample loop, desiccant cell, fill syringe, embedded HW5-P software. Order chamber door separately<br>HG2-XL HygroGen2-XL with touch screen, calibrated control/reference probe, set-point control & programmer function,<br>heated sample loop, 2 x desiccant cell, fill syringe, embedded HW5-P software.<br>MBW473-RP2-SET MBW473 dew point mirror, RP2 measurement head, SCS certification<br>MBW473 SH2-SET MBW473 dew point mirror, SH measurement head, SCS certification<br>Recommendation, SH placed inside the HG-XL on the top shelf, sampling directly from the inside<br>HG2-AutoCal-Code Extension (activation key): automatic calibration function<br>HG2-ExtRef-Code Extension (formerly Autocal+, requires AutoCal or RemoteAPI, activation key):<br>MBW/RHS External Reference Integration - enables MBW chilled mirror as external reference<br>HG2-TempExt-Code Extension (activation key): extended temperature range -5…60 °C<br>HG2-HumiExt-Code Extension (activation key): extended humidity range 2…99 %rh<br>HG2-RemoteSS-Code Extension (formerly Remote, activation key): Remote Screen Share<br>HG2-RemoteAPI-Code Extension (activation key): programming interface for remote control<br>**----- End of picture text -----**<br>
51
2022-V2
Humidity and Temperature Calibration
|**HygroGen2/ HygroGen2-XL accessories**|**HygroGen2/ HygroGen2-XL accessories**|
|---|---|
|**Consumables**||
|HG2-DES-3|Desiccant for molecular sieve(3 kg)|
|HG2-DC|Additional desiccant cell; pre-filled with molecular sieve|
|HG2-FILL|Fill tube and syringe|
|**Chamber doors, plugs andprobe sleeves**||
|HG2-D-888888|HG2-S door, 6 x 30 mm ports with 6 bungs;<br>order specific B8 sleeves to suit smallerprobe diameters|
|HG2-DP-00000|HG2-S clear acrylic door (no ports) for instruments<br>with displays|
|HG2-B8|30 mm bungfor HG2-D-888888|
|HG2-B8-xx|B8 probe sleeves for HG2-D-888888 (external: 30 mm; internal:<br>probe diameter see xx diameter codes)|
|HG2-D-xxxxx|HG2-S custom door for > 30 mm ports, please ask<br>your Rotronic dealer for the doors available|
|HG2-Bxx|Custom bung|
|HG2-Bxx-xx|Customprobe adaptor sleeves|
|**Accessories**||
|HG2-TB|HG2-S transit bag,lightweight|
|HG2-TC|HG2-S heavy-dutytransit case|
|HG2-AC3001-L/050|HygroClip2 calibration cable,50 cm,USB connector|
|HG2-HW5-V3|Software for HygroGen2|
|HG2-CAM|Probe sleeve with high definition USB cam|
HG2-D-888888 door with plugs and probe sleeves
Door cross section
HygroGen bag
HygroGen case
52
2022-V2
Humidity and Temperature Calibration
## Humidity standards
Equipped with Rotronic humidity standards, a suitable calibration device and the HW5 software, it is easy to calibrate and adjust probes on-site at your premises. It is also possible to calibrate and adjust probes with the handheld instrument HP32 (direct adjustment with the device, no software needed).
## **APPLICATIONS**
Calibration and adjustment of Rotronic probes (third-party probes also possible).
## **FEATURES**
- Traceable to national standard
- Ampoules contain unsaturated salt solutions
- Inexpensive calibration on site
- Simple and safe use
- Unlimited lifetime as long as the glass ampoules are kept sealed
- Practical packs of 5 ampoules of the same humidity value (approx. 0.8 ml per ampoule)
|**Order code**<br>~~es~~|**Nominal**<br>**value**<br>~~es~~|**Measurement uncertainty**<br>**at 23 °C**|**Quantity**|**PADS**<br>**Included**|
|---|---|---|---|---|
|EA00-SCS<br>~~es~~<br>~~ee~~|0,5 %rh<br>~~es~~|±0.3 %rh<br>~~eee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|5<br>~~eee~~|5<br>~~eee~~|
|EA00-BOX-SCS<br>~~es~~<br>~~ee~~<br>~~ee~~|0,5 %rh<br>~~es~~<br>~~ee~~||50<br>~~eee~~<br>~~ee~~|-<br>~~eee~~<br>~~ee~~|
|EA05-BOX25-SCS<br>~~es~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|5 %rh<br>~~es~~<br>~~ee~~||25<br>~~eee~~<br>~~ee~~<br>~~ee~~|25<br>~~eee~~<br>~~ee~~<br>~~ee~~|
|EA05-BOX-SCS<br>~~es~~<br>~~ee~~<br>~~ee~~|5 %rh<br>~~es~~<br>~~ee~~||50<br>~~ee~~<br>~~ee~~|50<br>~~ee~~<br>~~ee~~|
|EA10-SCS<br>~~es ~~<br>~~ee~~|10 %rh<br> ~~es~~||5<br>~~ee~~|5<br>~~ee~~|
|EA10-BOX-SCS<br>~~ee~~|10 %rh<br>~~ee~~||50<br>~~ee~~|-<br>~~ee~~|
|EA11-SCS<br>~~ee~~|11 %rh<br>~~ee~~||5<br>~~ee~~|5<br>~~ee~~|
|EA20-SCS<br>~~ee~~|20 %rh<br>~~ee~~||5<br>~~ee~~|5<br>~~ee~~|
|EA20-BOX-SCS|20 %rh||50|-|
|EA35-SCS|35 %rh|±0.4 %rh<br>~~a~~|5|5|
|EA35-BOX-SCS<br>~~=———~~|35 %rh<br>~~=———~~||50<br>~~a~~|-<br>~~a~~|
|EA50-SCS<br>~~=———~~|50 %rh<br>~~=———~~|±0.6 %rh<br>~~a~~|5<br>~~a~~|5<br>~~a~~|
|EA50-BOX-SCS<br>~~=———~~|50 %rh<br>~~=———~~||50<br>~~a~~|-<br>~~a~~|
|EA60-SCS<br>~~=———~~|60 %rh<br>~~=———~~||5<br>~~a~~|5<br>~~a~~|
|EA65-SCS<br>~~=———~~|65 %rh<br>~~=———~~||5<br>~~a~~|5<br>~~a~~|
|EA65-BOX-SCS<br>~~=———~~|65 %rh<br>~~=———~~||50<br>~~a~~|-<br>~~a~~|
|EA75-SCS<br>~~=———~~|75 %rh<br>~~=——— ~~|±0.7 %rh<br> ~~a~~|5<br>~~a~~|5<br>~~a~~|
|EA80-SCS|80 %rh||5|5|
|EA80-BOX-SCS|80 %rh||50|-|
|EA95-SCS|95 %rh|±0.8 %rh|5|5|
|EA95-BOX-SCS<br>~~nD~~|95 %rh<br>~~nD~~||50|-|
|EA-PADS<br>~~nD~~|-<br>~~nD~~|-|-|50|
## **Compatible**
## **Recommended accessories**
- With all calibration devices
- Textile pads in tubes (50 pc.) EA-PADS
## **Delivery package**
- SCS certificate
- Textile pads
- Calibration instructions
53
2022-V2
Humidity and Temperature Calibration
## Calibration devices
## **APPLICATIONS**
Rotronic calibration devices are small, airtight chambers that fit Rotronic probes precisely. The lower part of the device consists of a screw-on lid into which the humidity standard is poured on to an absorbent textile pad. The specified humidity is generated in the calibration device after a stabilization period. High humidity values require a longer stabilization period. The probe can then be calibrated or adjusted by comparison with the reference value of the humidity standard.
|**Order code**|**Use**|
|---|---|
|**Push-on calibration devices.**<br>**Gasket with O-ring and thumb screw**||
|ER-15|For 1 probe<br>Ø 14…15 mm<br>Brass, nickel-plated|
|EDM 15/15<br>ERV-15|For 2 probes<br>Ø 14…15 mm<br>Brass, nickel-plated<br>For 1 probe<br>Ø 14…15 mm<br>Vertical calibration position<br>Brass, nickel-plated|
|ER-05|For 1 probe<br>Ø 4…5 mm<br>Brass, nickel-plated|
|ER-12K|For 1 probe<br>Ø 12 mm<br>Brass, nickel-plated|
|**Calibration devices for specialprobes**||
|EGS|For all sword probes<br>Brass, nickel-plated|
|**Order code**|**Use**|**Use**|
|---|---|---|
|**Screw-on calibration devices. Gasket with seal face on probe.**<br>**Cannot be used for HC2A-Sprobes**|||
|EMV-25|For 1 probe<br>Ø 25 mm (PG11)<br>Vertical calibration position<br>Aluminum, Ematal-coated||
|**Calibration devices for specialprobes**<br>~~@~~|||
|WP-14-S|For bell probes<br>HC2-AW, HC2-AW-USB,<br>AW-DIO<br>POM, stainless steel 1.4305|~~@~~|
|HL-20-CAL|For HL-20<br>POM<br>Spring steel 1.4310||
54
2022-V2
Humidity and Temperature Accessories ~~ST~~
## Extension cables
## **For HC2A/HC2 probes**
The HC2A/HC2 extension cables extend the HC2A probes away from transmitters, The HC2A/HC2 extension cables extend the HC2A/HC2 probes away from transmitters, handheld instruments or data loggers.and data loggers. The HC2A/HC2 extension cables can be used up to 5 meters. For longer cable runs, use the AC3003 signal amplifier for distances up to 100 meters.
## **FEATURES**
- Range of application -40…90 °C
|**Extension cables for HC2A/HC2probes**<br>**Shaft**|**Extension cables for HC2A/HC2probes**<br>**Shaft**|**Extension cables for HC2A/HC2probes**<br>**Shaft**|**Extension cables for HC2A/HC2probes**<br>**Shaft**|
|---|---|---|---|
|**Order code**|**Cable length**|**Shaft**|**Color**|
|E2-F3A|30 cm|Normal|Black|
|E2-01A|1 m|||
|E2-02A|2 m|||
|E2-02A-S|2 m|Short[S]||
|E2-05A|5 m|Normal||
|E3-01A|1 m|Normal|White<br>Black, with metal|
|E3-05A<br>E2-02A-M|5 m<br>2 m|Normal<br>Normal||
|E2-02A-M|2 m|Normal|Black, with metal<br>connector|
**==> picture [157 x 212] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø15 mm<br>Ex-xxA<br>Ud<br> Ø15 mm<br>mm<br>111<br>mm<br>58<br>mm<br>mm 72<br>58<br>**----- End of picture text -----**<br>
Ex-xxA-S
## Extension cables
## **For use with HC2-S3C03(PT15) meteorological probe and analogue probes.**
## **FEATURES**
- Range of application -40…70 °C
|**Cables to connect an analog probe to a HP23-A, HF8, HL-NT**|**Cables to connect an analog probe to a HP23-A, HF8, HL-NT**|**Cables to connect an analog probe to a HP23-A, HF8, HL-NT**|
|---|---|---|
|**Order code**|**Cable length**|**Color**|
|A-01XX|1 m|Black|
**==> picture [37 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø15 mm<br>58 mm<br>**----- End of picture text -----**<br>
## HC2A/HC2 connector
## FEATURES
- Maximum wall thickness: 4 mm
- Hole diameter: 12.5 mm
- 30 cm long, color-coded wires
- Ends tin-plated
- Range of application: -40…100 °C
## **Order code: E2-XX**
55
2022-V2
Humidity and Temperature Accessories
## Extension cables
**==> picture [511 x 470] intentionally omitted <==**
**----- Start of picture text -----**<br>
Extension cables Ø15<br>1/4"<br>For HC2A/HC2 probes with open ends<br>The HC2A/HC2 probe extension cables with open ends can be used to integrate HC2A/HC2 probes<br>into users' analog or digital networks.<br>Extension cables for HC2A/HC2 probes with open ends<br>Order code Cable length Shaft Color Range of<br>application<br>Supply voltage 3.3 VDC (without electronic control)<br>E2-01XX 1 m Normal Black -40..90 °C<br>Ø15 mm<br>E2-02XX 2 m<br>E2-02XX-S 2 m Short [S]<br>E2-05XX 5 m Normal<br>E3-01XX 1 m Normal White<br>E3-02XX 2 m<br>E3-05XX 5 m<br>10<br>Supply voltage 5…24 VDC / 5…16 VAC (with electronic control)<br>E2-02XX-ACT/01 2 m Normal Black -40..70 °C<br>E2-05XX-ACT/01 5 m Ø 5<br>E2-10XX-ACT/01 10 m<br>E3-02XX-ACT/01 2 m Normal White<br>E3-05XX-ACT/01 5 m<br>E3-10XX-ACT/01 10 m<br>Supply voltage 5…40 VDC / 6…28 VAC (with electronic control) E2-01xx E2-02xx-S<br>E2-05XX-ACT-HV 5 m Black 5 m<br>Wire assignment<br>Green VDD (+) 3.3 VDC<br>5…24 VDC / 5…16 VAC<br>5…40 VDC / 6…28 VAC<br>Gray GND Digital and power supply GND<br>Red RxD UART<br>Blue TxD UART<br>White Out1 Analog output 1,<br>standard humidity 0…100 %RH = 0...1 V<br>Brown Out2 Analog output 2,<br>standard temperature -40…60 °C = 0...1 V<br>Yellow AGND Analog GND<br>(connect to GND when using docking stations)<br>12<br>111<br>mm<br>72<br>**----- End of picture text -----**<br>
56
2022-V2
Humidity and Temperature Accessories
## Digital signal amplifiers
Using a digital signal amplifier, it is possible to achieve probe line distances of up to 50 meters.
## **FEATURES**
- Color: black
- Range of application: -40...70 °C
- Power supply: 3.3 V / 4.8 mA
**==> picture [338 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
Digital signal amplifiers<br>Order code Description Cable length / Shaft<br>AC3003 UART signal amplifier, probe and in- Normal shaft<br>strument side with luster terminals<br>AC3003/10 AC3003 with luster terminal and not 10 m<br>AC3003/20 pre-assembled Cat. 5 cable, normal 20 m<br>AC3003/50 shaft 50 m<br>**----- End of picture text -----**<br>
**==> picture [69 x 256] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø15 mm<br>Ø17 mm<br>mm<br>58<br>75 mm<br>**----- End of picture text -----**<br>
AC3003
## Service cable HF transmitters
## **FEATURES**
- Transfer of measured values from HF3/4/5/7 to HP32/23
- USB-Mini to 7-pin connector
**==> picture [337 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
Service cable for HF-series transmitters<br>Order code Description<br>AC2001 Service cable for HF-series transmitters<br>**----- End of picture text -----**<br>
Ø15 mm ø5 8
AC2001
57
2022-V2
Humidity and Temperature Accessories
**==> picture [512 x 528] intentionally omitted <==**
**----- Start of picture text -----**<br>
USB converters Ø15 mm Ø15 mm<br>For HC2A/HC2 probes<br>FEATURES<br>• To connect HC2A/HC2 probes to a PC via the USB interface<br>• Requires HW5 software on the PC<br>• Power supply via USB interface<br>• Range of application: -40...70 °C<br>• Cable length: 2.8 m<br>USB converters for HC2A/HC2 probes<br>Order code Description Shaft<br>AC3001 Active UART to Short shaft<br>AC3001-L USB converter cable Long shaft [L]<br>XD-AC3001 Active UART to Short shaft<br>USB converter cable for<br>XD probes Ø17 mm<br>Ø17 mm<br>AC3001 AC3001-L<br>RS-485 and Modbus converter ø15<br>1/4"<br>For HC2A/HC2 probes<br>FEATURES<br>• To connect HC2A/HC2 probes to a RS-485 or Modbus network<br>• It is possible to switch between Modbus and RS-485 protocol in the HW5 software<br>• Power supply: 5…28 VDC<br>• Range of application: -40...70 °C<br>Note<br>Self-heating of the converter can lead to errors in the measured values; it is therefore advisable to<br>place the probe a short distance away using an extension cable (e.g. E2-F3A).<br>10<br>RS-485 / Modbus converters<br>Order code Description Cable length ø5<br>E2-05XX-MOD Converter cable for HC2A/HC2 5 m<br>RS-485 and MODBUS<br>72 mm<br>111 mm<br>75 mm<br>75mm<br>12<br>111<br>**----- End of picture text -----**<br>
58
2022-V2
Humidity and Temperature Accessories
## Service cables
## **For HF, HL-20**
## **FEATURES**
- Connects Rotronic instruments via their service interface (UART) to a USB interface
- Requires HW5 software
- For programming (settings, scaling, firmware update, etc.)
- Two different types:
AC3006, the instrument must be supplied with power.
AC3009, the instrument is supplied with power via the USB interface.
AC3006 in combination with a 2-wire type: with all 2-wire types (HF320, HF420, HF520, HF620, HF720) ensure that the computer or laptop is galvanically isolated from the main power supply.
||**AC3006**|**AC3009**|**AC0006**|
|---|---|---|---|
|HF1||||
|HF3||||
|HF4||||
|HF5||||
|HF7||||
|TF5||||
|PF4||||
|PF5||||
|HL-20||||
|BL-1D||||
|HL-1D||||
|TL-1D||||
|CL11||||
|HP32||||
|CP11||||
|AwTherm||||
|CRP5||||
**==> picture [89 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power<br>supply<br>AC3006<br>AC3006<br>Power<br>supply<br>AC3009<br>u c<br>AC3009<br>**----- End of picture text -----**<br>
**==> picture [63 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
AC3006 / AC3009<br>**----- End of picture text -----**<br>
59
2022-V2
Humidity and Temperature Accessories
## HC2 simulators
## **FEATURES**
- Humidity / Temperature simulators with fixed values and certificate
- For system validation
- Values cannot be changed with the HW5 software
- Range of application: -40...100 °C
|**Service cables**|**Service cables**|**Service cables**|
|---|---|---|
|**Order code**|**Humidity**|**Temperature**|
|HC2-SIMC-000/0023|0 %RH|23 °C|
|HC2-SIMC-035/0023|35 %RH|23 °C|
|HC2-SIMC-050/0023|50 %RH|23 °C|
|HC2-SIMC-080/0023|80 %RH|23 °C|
Other types available on request.
## Protective caps
## **FEATURES**
- Protects probes/connectors during cleaning cycles against water and chemical substances, e.g. H2O2
|**Protective caps**|**Protective caps**|
|---|---|
|**Order code**|**Protection**|
|Protection-E2/E3|Connectors|
|Protection-Filter|Sensor note: onlycompatible with HC2probes|
|Protection-HC2|Complete HC2A/HC2probe|
**==> picture [152 x 131] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection filter<br>Protection HC2 Protection E2/E3<br>**----- End of picture text -----**<br>
## Mounting kits
|**Mounting kits**|**Mounting kits**|
|---|---|
|**Order code**|**Description**|
|AC5002|DIN top-hat rail adapter for PF4,PF5,HF4,HF5,HF8|
**==> picture [28 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
AC5002<br>**----- End of picture text -----**<br>
60
2022-V2
Humidity and Temperature Accessories
## Mounting gland with flange
|**Mounting gland with flange for temperatures <100 °C**|**Mounting gland with flange for temperatures <100 °C**|
|---|---|
|**Order code**|**Description**|
|AC5005|Mounting gland with flange for 15 mm probes<br>M20 x 1.5/to 100 °C|
**==> picture [28 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
AC5005<br>**----- End of picture text -----**<br>
|**Mounting glands without flange**|**Mounting glands without flange**|
|---|---|
|**Order code**|**Description**|
|AC1303-M|Mounting gland for 15 mm probe<br>M20 x 1.5/brass,nickel-plated/to 200 °C|
|AC1304-M|Mounting gland for 25 mm probe<br>M32 x 1.5/brass,nickel-plated/to 200 °C|
|AC1301-MEX|Mounting gland for 15 mm ATEX probes<br>M25 x 1.5/brass,nickel-plated/to 95 °C|
|**Mounting flange**|**Mounting flange**||
|---|---|---|
|**Order code**|**Use with**|**Description**|
|AC1305|AC1303-M|Mounting flange for AC1303-M<br>Ø 80 mm/steel,nickel-plated/to 200 °C|
|AC1306|AC1304-M|Mounting flange for AC1304-M<br>Ø 80 mm/steel,nickel-plated/to 200 °C|
|AC1307|AC1301-MEX|Mounting set for AC1301-MEX<br>Ø 80 mm/steel,nickel-plated/to 200 °C|
AC1303-M AC1304-M AC1301-MEX
AC1305 AC1306
61
2022-V2
|**Humidity and Temperature**|||
|---|---|---|
|**Temperature**<br>eC)|||
|**Differential pressure**|||
|**CO2**|||
|**Applications**|||
|**Rotronic Monitoring System – RMS**<br>es)|es)|es)|
|**Software**<br>@|@|@|
|**EcoLine – Humidity & Temperature**|||
|**Services**|||
|**Theory**|||
62
2022-V2
Temperature Probes
## PT100 probes
Rotronic offers a wide range of its own PT100 probes, but other 4-wire temperature probes can also be used.
Accuracy: Class A Wire technique: 4-wire Connection: 4-pin Binder connector plug τ 90: Time needed to reach 90% of the new measured value after a temperature increase (air velocity = 2 m/s)
AC1900 AC1902
**==> picture [28 x 55] intentionally omitted <==**
**----- Start of picture text -----**<br>
AC1904<br>AC1909<br>**----- End of picture text -----**<br>
**==> picture [54 x 79] intentionally omitted <==**
**----- Start of picture text -----**<br>
PT100 input<br>1<br>1 3 2<br>2 4 3<br>4<br>4-wire PT100<br>**----- End of picture text -----**<br>
|**Order code**|**Probe type**|**Temperature**<br>**range**|**Cable/handle operating range**||
|---|---|---|---|---|
|AC1900|Fixed probe<br>100 x 3 mm<br>DIN 1.4404|-50...300 °C|-40...105 °C<br>without cable|loo_———>|
|AC1902|Insertion probe with<br>handle 250 x 3 mm<br>DIN 1.4404|-50...350 °C|-40...105 °C<br>1 m, PUR cable|~~a~~|
|AC1903|Cable probe 200 x 6 mm<br>Not waterproof<br>DIN 1.4404|-50...350 °C|-40...105 °C<br>2 m, thermoplastic cable|~~$=~~|
|AC1904|Cable probe 50 x 6 mm<br>Waterproof<br>DIN 1.4301|-50...105 °C|-40...105 °C<br>2 m, thermoplastic cable|~~a~~|
|AC1909|Fixed probe for<br>measurements in air,<br>100 x 4 mm<br>DIN 1.4401|-50...150 °C|-40...105 °C<br>without cable|OO<br>—————|
|AC1913-A|Kapton foil probe,<br>20 x 15 x 2 mm|-50...200 °C|-40...105 °C<br>1 m, four PFA wires||
|AC1916-A-T|Cable probe 60 x 6 mm<br>Waterproof<br>DIN 1.4571|-30...200 °C|-40...85 °C<br>2 m PTFE cable|~~a~~|
63
2022-V2
Temperature Probes
|**Order code**|**Probe type**||
|---|---|---|
|HC2-PT100-B4|Adapter for PT100 probes<br>to HP32, HF5, PF4 and PF5||
|AC1607/05|Extension cable for PT100 probes, 4-pin Binder male/female connectors<br>Max. 85 °C,min. -40 °C|5 m|
|AC1607/10|Extension cable for PT100 probes, 4-pin Binder male/female connectors<br>Max. 85 °C,min. -40 °C|10 m|
|AC1607/25|Extension cable for PT100 probes, 4-pin Binder male/female connectors<br>Max. 85 °C,min. -40 °C|25 m|
## **Compatible**
**Delivery package**
- Transmitters
TF5, PF4, PF5
- Temperature probe
64
2022-V2
Temperature Transmitters
## TF5 series
The TF5 series is compatible with all PT100 probes in the Rotronic range. This device generation includes a unique calibration and adjustment function.
## **FEATURES**
- Interchangeable PT100 probes
- Range of application electronics: -40…60 °C / 0…100 %rh -10…60 °C with display
- Temperature measurement with PT100 probe, 4-pin Binder connection
- Service interface
## **Power supply**
- Low voltage: 2 or 3-wire
## **Signal outputs**
- Current output
- Voltage output
## **Version**
- Wall version
## **Output parameter**
- Temperature
## **Output scaling**
- Temperature: range selectable, standard: -40…60 °C
## **Display**
- Display with backlight (excl. 2-wire, trend indicator and keypad)
- Without display
65
2022-V2
Temperature Transmitters
## TF5 wall version
## **APPLICATIONS**
Production processes, storage, transportation and drying processes.
## **2-wire**
|Order code|TF520 Type W|
|---|---|
|Output signal|4…20 mA|
|Supplyvoltage|10...28 VDC|
|Display|Optional(without backlight)|
|Temperature range|Scalable*|
|Probes|Interchangeable(-100...600 °C)|
**3-wire**
Order code TF53x Type W Output signals 0…1 V 0…5 V 0…10 V 0…20 mA 4...20 mA Customer selection possible* Supply voltage 15…40 VDC / 12…28 VAC Display Optional (with backlight) Temperature range Scalable* Probes Interchangeable (-100...600 °C) ~~|~~
Wall version, type W ~~=~~
PT100 input
**==> picture [50 x 41] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>1 3 2<br>2 4 3<br>4<br>**----- End of picture text -----**<br>
4-wire PT100
## **Compatible**
- PT100 probes
- All PT100 probes with 4-wire connection
- HW5
## **Recommended accessories**
- Service cable AC3006 / AC3009* • Extension cable 5 m AC1607/05 • Mounting kit DIN top-hat rail AC5002
## **Delivery package**
- Product qualification
- Short instruction manual
- Screws and plugs for mounting
- Connector for third-party probe
- Requires optional HW5 software and service cable.
66
2022-V2
Temperature Transmitters
**==> picture [513 x 323] intentionally omitted <==**
**----- Start of picture text -----**<br>
TF520 TF53x<br>Technical data<br>2-wire 3-wire<br>General<br>Parameter Temperature<br>Housing material ABS<br>Protection IP65<br>Dimensions 129 x 72 x 45 mm<br>Weight 220 g<br>Probe connection 4-pin Binder, threaded coupling<br>Display/Operation LCD, 1 or 2 decimals LCD, 1 or 2 decimals<br>optional without backlight with backlight<br>Menu navigation, 4 keys Menu navigation, 4 keys<br>Electrical connections Connections: screw terminals inside<br>Cable gland: M16<br>Power supply 10...28 VDC 15…40 VDC / 12…28 VAC<br>Current consumption <20 mA <20 mA<br>Range of application / Storage conditions -40…60 °C / -10…60 °C (with LCD), 0…100 %rh<br>Temperature scaling Max. -100...200 °C<br>Firmware update Via HW5 software<br>Service interface UART service interface (Universal Asynchronous Receiver Transmitter)<br>CE / EMC compatibility EMC Directive 2014/30/EU<br>Fire protection class Corresponds to UL94-HB<br>Analog output<br>Number 1<br>Current 4…20 mA 0(4)…20 mA<br>Voltage N/A 0…1/5/10 V<br>Permissible load ≤ 500 Ω ≤ 500 Ω (current output)<br>≥ 1 kΩ/V (voltage output)<br>**----- End of picture text -----**<br>
67
2022-V2
Temperature Data loggers
## TL-CC1
The Rotronic cold-chain temperature logger TL-CC1 is easy to configure (without software), generates PDF reports automatically and comes at an unbeatable price.
## **APPLICATIONS**
Monitoring of the cold chain during the transportation of sensitive freight such as pharmaceuticals, foods and technical products.
## **FEATURES**
- PDF report generation without software installation
- Freely configurable
- Clear alarm indication
- All-in-one logger: configuration tool, PDF report, instruction manual and calibration certificate
- High storage capacity, single use, single journey
- Conforms EN 12830
|**Technical data**|**TL-CC1**|
|---|---|
|**General**||
|Parameter|Temperature|
|Temperature sensor|NTC thermistor|
|Accuracyat -30...70 °C|±0.5 K|
|Resolution|0.1 °C|
|Range of application/Storage conditions|-30...70 °C/-22...158 °F,< 80 %rh|
|IPprotection|IP65(inplastic bag)|
|Weight|Approx. 10g|
|Battery|CR2032(not replaceable)|
|Dimensions without bag|80 x 43 x 2.5 mm|
|Dimensions with bag|105 x 55 x 2.5 mm|
|Logginginterval|0.5/5/10/30/60/90/120 min.|
|Start delay|0.5/5/10/30/60/90/120 min.|
|Alarm ranges|-20…-10 °C, -10…0 °C, 2…8 °C, 0…15 °C,<br>0…25 °C,15…25 °C,freelyselectable values|
|Alarm type|Deactivated,single or cumulative|
|Storageperiod|12 months|
|Storage capacity|8192 datapoints|
|Event marking|Upto 8points|
|Use|START/STOP button,MARK button|
|Alarm indication|LED indicators<br>PDF reports|
|Communication|USB 2.0port,type A|
|Operatingsystem|Windows|
|Conformity|EN 12830|
PDF report
## **Delivery package**
- 10 pc. per box
- Short instruction manual
68
2022-V2
Temperature Data loggers
## TL-1D
TL-1D temperature data logger: compact, accurate and inexpensive.
## **APPLICATIONS**
Warehouses, factories, museums, office buildings, cleanrooms, transportation, libraries, test facilities, room monitoring in HVAC systems.
## **FEATURES**
- Accuracy: ±0.3 K, at 23 °C ±5 K
- Compact with very high level of IP protection
- High storage capacity: 32,000 lines
- Free evaluation and configuration software HW5
- Very long battery life: up to 3 years
- Conforms to EN12830. Version 3.0 and later
- Programmable logging mode
**==> picture [328 x 275] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Technical data|TL-1D|
|General|
|Parameter|Temperature|
|Sensor type|NTC thermistor|
|Accuracy at 23 °C ±5 K|±0.3 K|
|Range of application /|-30…70 °C / 0…100 %rh|
|Storage conditions|
|IP protection|IP67|
|Weight|85 g|
|Dimensions|90 x 60 x 23 mm|
|Logging interval|30 s…24 h|
|Battery|1 x CR2|
|Battery life|Up to 3 years (logging interval 1 h)|
|Battery charge indicator|Yes (HW5 software, display and LED indicator)|
|Storage capacity|32,000 lines|
|Function|MIN/MAX/AVG|
|Display|LCD|
|Resolution|0.1 °C|
|Display refresh rate|5 s (standard) or same as logging interval|
|LED indicators|2 LEDs|
|Right LED flashes green during data logging|
|Left LED flashes red when limits broken or low battery|
|Communication|USB-Mini port (cable optional)|
|Standards|EN12830 (V3.0 and later)|
**----- End of picture text -----**<br>
USB-Mini port Battery (settings and data compartment download)
## **Configuration & evaluation**
The values stored in the TL-1D can be downloaded with the HW5 software and displayed graphically. The user determines the logging interval, the alarm limits, the recording mode and much more.
**==> picture [157 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
_——<br>60<br>90 23<br>**----- End of picture text -----**<br>
## **Delivery package**
## **Recommended accessories**
- Short instruction manual
- USB service cable
AC0003
- Battery CR2
- Function and calibration certificate
69
2022-V2
|**Humidity and Temperature**|||
|---|---|---|
|**Temperature**|||
|**Differential pressure**<br>(0)|||
|**CO2**|||
|**Applications**|||
|**Rotronic Monitoring System – RMS**<br>es)|es)|es)|
|**Software**<br>@|@|@|
|**EcoLine – Humidity & Temperature**|||
|**Services**|||
|**Theory**|||
**Video differential pressure** Interested? Then scan the QR code! ~~«Bs~~ IB
70
2022-V2
Differential pressure Transmitters
## PF4/PF5 series
The thermal measurement technique of the PF4 transmitter allows exact measurements in the smallest of ranges. The differential pressure transmitter enables Rotronic customers to measure a further important parameter in addition to humidity, temperature, low dew point and CO2.
## **FEATURES**
- Accuracy: ±1.0 % full scale
- Fast response time
- Freely configurable analog signals
- Integrated relay switch contact
- High resistance to pressure
- Thermal mass flow measurement at low flow rate
- High immunity to dust and humidity in the environment
- Integrated damping function for variable response times
## **Power supply**
- Low voltage: 3-wire
## **Signal outputs**
- Current output
- Voltage output
- Ethernet
- Relay switch contact
## **Version**
- Wall mount
## **Output parameters**
- Differential pressure
- Differential pressure & temperature
- Differential pressure, temperature & relative humidity
## **Measurement ranges**
- -25...+25 Pa / -50…+50 Pa / -100...+100 Pa / -250...+250 Pa / -500…+500 Pa
## **Display**
- Display with backlight, trend indicator and keypad
- Without display
71
2022-V2
Differential pressure Transmitters
## PF4/PF5 series
## **APPLICATIONS**
Clean rooms, operating theaters, HVAC, filter technology and applications where small pressure differences prevail.
## **BENEFITS**
- Flow or diaphragm differential pressure sensors
- 1 to 3 analog outputs, 1 analog input
**==> picture [55 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
PF4 with PT100<br>**----- End of picture text -----**<br>
- Network integration (Ethernet)
- Modbus TCP or RTU over RS485
|• 1 to 3 analog outputs, 1 analog input<br>• Network integration (Ethernet)<br>• Modbus TCP or RTU over RS485|• 1 to 3 analog outputs, 1 analog input<br>• Network integration (Ethernet)<br>• Modbus TCP or RTU over RS485|• 1 to 3 analog outputs, 1 analog input<br>• Network integration (Ethernet)<br>• Modbus TCP or RTU over RS485|• 1 to 3 analog outputs, 1 analog input<br>• Network integration (Ethernet)<br>• Modbus TCP or RTU over RS485|PF4 with PT100|PF4 with PT100|
|---|---|---|---|---|---|
|• Potential-free relay with switch contacts<br>**3-wire**<br>**Order code**<br>**PF44x-1**<br>**PF44x-L**<br>Output signals<br>0…1/5/10 V<br>0/4…20 mA<br>Relayswitch contact<br>Ethernet<br>Relay Switch contact<br>Supplyvoltage<br>15…48 VDC/16…35 VAC<br>Display<br>Optional<br>~~=~~||||||PF5 with HC2-A|
|**3/4-wire**||||||
||**Order code**|**PF54x-1**|**PF54x-L**|||
||Output signals|0…1/5/10 V|Ethernet|||
|||0/4…20 mA|Relay Switch contact|||
|||Relayswitch contact||||
||Supplyvoltage|18…48 VDC/16…35 VAC||||
||Display|Optional||||
**==> picture [28 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
20.5<br>12.5<br>26<br>**----- End of picture text -----**<br>
## **Compatible**
## **Recommended accessories**
- HW5
## **Delivery package**
- Service cable AC3006 / AC3009* • Temperature probe AC19xx • Mounting kit DIN top-hat rail AC5002
- HC2A-S probe
- Factory adjustment certificate
- Short instruction manual
- Screws and plugs for mounting
- Requires optional HW5 software and service cable.
72
2022-V2
Differential pressure Transmitters
## PF4/PF5 series
**==> picture [512 x 594] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data PF44X-L PF54X-L<br>PF44X-1 PF54X-1<br>Analog & digital Analog & digital<br>Analog 3-wire Analog 3/4-wire<br>3-wire 3/4- wire<br>General<br>Parameters Differential pressure, temperature and relative humidity<br>Housing material ABS<br>IP protection IP65 IP40 IP65 IP40<br>Mounting position Wall mount<br>Dimensions 129 x 72 x 45 mm<br>Weight 243 g<br>Display Coloured TFT display<br>Electrical connections Screw terminals M16 Screw terminals M16 Screw terminals M16 Screw terminals M16<br>cable gland cable gland, socket cable gland cable gland, socket<br>Power supply 15…48 VDC / 16…36 VAC (galvanically isolated)<br>Current consumption <300 mA @ 24 VDC<br>Range of application / Storage conditions -5…60°C / 0…100%rh, non-condensing<br>Firmware upgrade Via HW5 software<br>Service interface UART service interface (inside device)<br>CE / EMC compatibility EMC-Directive 2014/30/EU<br>Fire protection class Corresponds to UL94-HB<br>Differential pressure measurement<br>Measurement principle Thermal mass flow measurement Membran sensor<br>Measurement ranges ±10 Pa / ±25 Pa / ±50Pa / ±100 Pa / ±250 Pa ±25 Pa / ±50Pa / ±100 Pa / ±250 Pa / ±500 Pa<br>/ ±500 Pa<br>Medium Air and non-agressive gases<br>Accuracy at 23°C ±3 K ±1.0 %FFS<br>Long-term stability ±0.05 % FSS/year (typ.) ±0.25 % FSS (typ.) per year @ ±250 and ±500<br>±0.1 % FSS/year (max.) Pa measurement range<br>±0.3125 % FSS (typ.) per year @ ±100 Pa<br>measurement range<br>±0.625 % FSS (typ.) per year @ ±50 Pa<br>measurement range<br>±1.25 % FSS (typ.) per year @ ±25 Pa<br>measurement range<br>Measurement interval 1 s<br>Pressure resistance 5 bar 0.7 bar<br>Leak rate <10.8 ml/h 0<br>Pressure connections Tubing connector Ø 4 mm x 10 mm<br>Measurement of temperature and relative humidity (type-dependent)<br>Probe connections Temperature: 4 pin Binder for 4-wire PT100<br>Humidity: Rotronic E2 for Rotronic HC2A-S probe<br>Accuracy: probe dependent<br>Outputs<br>Analog outputs Min. 1, max. 3, freely configurable<br>Analog output type 0 to 1 V<br>0 to 5 V<br>0 to 10 V<br>0 to 20 mA<br>4 to 20 mA<br>Relais / Switch output 1 relay potential-free change-over switch<br>(NC - COM - NO)<br>Accuracy analog output @ 23°C Voltage output: ±1 mV/V Current output: ±20 μA<br>Permissible load > 1 kΩ/V (voltage output) / < 500 Ω (current output)<br>**----- End of picture text -----**<br>
73
2022-V2
**Humidity and Temperature Temperature Differential pressure CO2** eee **Applications Rotronic Monitoring System – RMS Software EcoLine – Humidity & Temperature Services Theory**
**Video CO2** Interested? Then scan the QR code!
74
2022-V2
CO2 Data Loggers
## CL11 benchtop display unit
Benchtop display unit for monitoring indoor air quality. Measures and records CO2, relative humidity and temperature.
## **APPLICATIONS**
Indoor air quality (IAQ) measurements in offices, conference rooms, schools, etc.
## **FEATURES**
- Benchtop or wall mounting
- Measures and records CO2, relative humidity and temperature
- Accuracy: ±30 ppm, ±3 %rh, ±0.3 K
- ROTRONIC HYGROMER[®] IN-1 humidity sensor
- 40,000 data point memory for CO2, humidity and temperature values
- Maximum, minimum and average value display
- Adjustable audible and visual CO2 alarm
- Real-time clock
- Includes free logging and configuration software HW5
|**Order code**|**CL11**|
|---|---|
|Probe type|CO2: infrared (NDIR) with automatic calibration (ABC)|
||Humidity: ROTRONIC HYGROMER®IN-1|
||Temperature: NTC|
|CO2measurement range|0...5000ppm|
|Range of application|0...50 °C/0...95 %rh,non-condensing|
|Material|ABS|
|Power supply|Onlywith AC adapter|
|IPprotection|IP30|
**==> picture [168 x 116] intentionally omitted <==**
**----- Start of picture text -----**<br>
120 mm<br>= 45 mm<br>62 mm<br>157 mm<br>85 mm<br>**----- End of picture text -----**<br>
## **Delivery package**
## **Recommended accessories**
- Short instruction manual
- AC adapter AC1214
- Rotronic software HW5
- USB cable
- Humidity calibration device
- Humidity calibration device ER-15 • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80%rh EA80-SCS • External temperature probe AC1215
- Factory adjustment certificate
75
2022-V2
CO2 Data Loggers
## CO2 DISPLAY
Room / Wall panel for monitoring indoor air quality. Measures and records CO2, relative humidity and temperature.
## **APPLICATIONS**
Indoor air quality (IAQ) measurements in offices, conference rooms, schools, etc.
## **FEATURES**
- Benchtop or wall mounting
- Measures and records CO2, relative humidity and temperature
- Accuracy: ±30 ppm, ±2.5 %rh, ±0.3 K
- ROTRONIC HYGROMER[®] IN-1 humidity sensor
- 18,000 data point memory for CO2, humidity and temperature values
- Adjustable, visual CO2 alert indicator
• Data download via USB flash drive
• Display of date and time **Order code CO** 2 **Display** Probe type CO2: infrared (NDIR) with automatic calibration (ABC) Humidity: ROTRONIC HYGROMER[®] IN-1 Temperature: NTC CO2 measurement range 0...5000 ppm Range of application 0...50 °C / 0...95 %rh, non-condensing Material ABS ~~|~~ Power supply AC adapter, 12 V Dimensions 330 x 250 x 50 mm ~~a~~
**==> picture [6 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
52<br>**----- End of picture text -----**<br>
130 | 330 ~~j I]~~
## **Delivery package**
## **Recommended accessories**
- Short instruction manual
- Mounting hardware
- Factory adjustment certificate
- Humidity calibration device
- Humidity calibration device ER-15 • Humidity standard for calibration 80%rh EA80-SCS • Humidity standard for calibration 35 %rh EA35-SCS
76
2022-V2
CO2 Handheld instrument ~~ST~~
## CP11
Portable monitoring of indoor air quality. Measures and records CO2, relative humidity and temperature.
## **APPLICATIONS**
Mobile inspections and random tests of indoor air quality in offices, conference rooms, schools, etc.
## **FEATURES**
- Measures and records CO2, relative humidity and temperature
- Accuracy: ±30 ppm, ±2.5 %rh, ±0.3 K
- ROTRONIC HYGROMER[®] IN-1 humidity sensor
- 18,000 data point memory for CO2, humidity and temperature values
- Maximum, minimum and average value display
- Adjustable audible CO2 alarm
- Adjustable automatic power off function
• Includes logging and configuration software, USB data cable and case
**Order code CP11** Probe type CO2: infrared (NDIR) with automatic calibration (ABC) Humidity: ROTRONIC HYGROMER[®] IN-1 Temperature: NTC CO2 measurement range 0...5000 ppm Range of application 0...50 °C / 0...95 %rh, non-condensing Material ABS Power supply 4 AA batteries / optional AC adapter ~~a~~ IP protection IP30
42
## **Delivery package**
## **Recommended accessories**
- Short instruction manual
- 4 x AA batteries
- Rotronic software HW5
- USB cable
- 5 VDC AC adapter AC1214 • Humidity calibration device ER-15 • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80%rh EA80-SCS
- Soft case
- Factory adjustment certificate
77
2022-V2
CO2 Technical data
**==> picture [513 x 458] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data CL11 CP11 CO2 Display<br>General<br>Parameters CO2, relative humidity and temperature<br>Memory capacity 40,000 values with time stamp, 18,000 values with time stamp, 18,000 values with time stamp,<br>automatic recording automatic recording automatic recording<br>(%rh / °C / ppm) (%rh / °C / ppm) 99 single values (%rh / °C / ppm)<br>with time stamp, manual<br>recording (%rh / °C / DP /<br>WBT / ppm)<br>Housing material / IP protection ABS / IP30<br>Dimensions 157 x 120 x 45 mm 77 x 42 x 234 mm 330 x 250 x 50 mm<br>Weight 200 g 290 g 1400 g<br>Display Two-line LCD with backlight<br>Alarm Audible and visual, adjustable Audible, adjustable for Visual, adjustable for<br>for CO2 measurement CO2 measurement CO2 measurement<br>Power supply AC adapter AC1214 4 AA batteries / optional AC adapter<br>AC adapter AC1214<br>Current consumption 50 mA 40 mA <700 mA<br>Application temp. housing / 0...50 °C / 0...95 %rh, non-condensing<br>electronics<br>Service interface USB-Mini port<br>CE / EMC compatibility CE conformity 2014/30/EU<br>CO2 measurement<br>Measurement principle Infrared (NDIR) with automatic calibration (ABC)<br>Measurement range 0…5000 ppm<br>Accuracy at 23 °C ±5 K ±30 ppm ±5 % of measured value<br>Null drift <10 ppm/year<br>Maintenance No maintenance (standard indoor applications)<br>Humidity measurement<br>Sensor ROTRONIC HYGROMER® IN-1<br>Measurement range 0…100 %rh<br>Accuracy at 23 °C ±5 K <2.5 %rh (10...90 %rh)<br>Adjustment points 35, 80 %rh<br>Long-term stability <1.5 %rh/year<br>Response time <30 s τ63, without filter<br>Temperature measurement<br>Sensor NTC<br>Measurement range -20..60 °C<br>Accuracy at 23 °C ±5 K ±0.3 K<br>Response time 4 s τ 90<br>**----- End of picture text -----**<br>
78
2022-V2
**==> picture [516 x 680] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Humidity and Temperature|
|Temperature|
|©|
|Differential pressure|
|Wy)|
|CO2|
|©|
|Applications|
|<>|
|Rotronic Monitoring System – RMS|
|€|
|Software|
|EcoLine – Humidity & Temperature|
|90|
|Services|
|Theory|
|Oy|
|Video water activity|rsile|
|Interested? Then scan the QR code!|
|Video CRP5|
|Interested? Then scan the QR code!|
|Video differential pressure|
|Interested? Then scan the QR code!|
**----- End of picture text -----**<br>
79
2022-V2
Applications Water activity
## Standalone water activity measurement head AwEasy
The AwEasy is a mobile device for easy and fast measurements of the water activity. The measurement head with Bluetooth can be used with the Smartphone together with the AwEasy App for iOS and Android. The AwEasy has also a small display, a light ring as an indicator and a wireless charger for an easy handling.
## **APPLICATIONS**
Aw checks of cheese, meat, tobacco, building materials, animal feeds, bakery products, paper, medicines, in horticulture and agriculture, etc.
## **FEATURES**
- The reliable AW Quick mode for quick results (typical 4 - 5 min)
- Easy use with a Smartphone App for iOS and Android
- Standalone measuring device with light ring and display
• Long battery life with wireless charging
**==> picture [23 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø68 mm<br>**----- End of picture text -----**<br>
|**Probe**<br>~~CT~~|**Probe**<br>~~CT~~|
|---|---|
|Sensor<br>~~CT~~<br>~~a~~|HYGROMER WA-1<br>~~CT~~|
|Accuracy @23 ±5 °C<br>~~a~~<br>~~a~~|± 0.008 aw/0.8 %rh/±0.1 K|
|Operatingconditions<br>~~a~~<br>~~a~~|0…70°C/0…100%rh|
|Storage conditions<br>~~a~~<br>~~a~~<br>~~RR~~|-10…70°C/0…100%rh|
|Long-term stability<br>~~a~~<br>~~RR~~|< 1 %rh/ year(normal conditions)|
|**Functions**<br>~~RR~~<br>~~CO~~||
|Parameters shown<br>~~CO~~<br>~~a~~<br>~~a~~|aw,%rh,°C,°F<br>~~CO~~|
|Status light<br>~~a~~<br>~~a~~|Yes|
|Long-term stability<br>~~a~~<br>~~a~~|< 1 %rh/ year(normal conditions)|
|AWQuick Mode<br>~~a~~<br>~~a~~|Yes|
|Firmware update<br>~~a~~<br>~~a~~<br>~~a~~|Direct over the App|
|Protocols(values)<br>~~a~~<br>~~a~~|Date,time,aw/rh/°C/°F,aw setpoint,serial no.,etc.|
|HW5 and HygroLab compatibility<br>~~a~~<br>~~a~~<br>~~a~~|No|
|Acoustic alarm<br>~~a~~<br>~~a~~|No|
|Calculations<br>~~aa~~|Nopsychrometric calculations available|
|**Hardware**<br>~~a~~<br>~~CO~~||
|Batterie capacity<br>~~CO~~<br>~~a~~<br>~~a~~|500 mAh<br>~~CO~~|
|Display<br>~~a~~<br>~~a~~|1.2” LCD color display<br>Multifunctional touch button|
|Button<br>~~a~~<br>~~a~~|Multifunctional touch button<br>|
|USB cable<br>~~a~~<br>~~a~~|USB-A to USB-C<br>|
|**Housing**<br>~~aCO~~||
|Dimensions<br>~~CO~~<br>~~a~~|Ø68 x 65 mm<br>~~CO~~|
|Housingmaterial<br>~~a~~|Aluminum,stainless steel & PC|
|Weight<br>~~a~~|600g|
|CE conform<br>~~a~~|CE 2014/30/EU|
|IPprotection rating<br>~~a~~|IP65|
## **Compatible**
## **Recommended accessories**
- Smartphone with iOS and Android
- Sample holders
Sample holders WP-14-S WP-40 WP-40TH • Calibration device WP-14-S • Calibration standards EAxx-SCS • Disposable sample containers PS-14, PS-40
## **Delivery package**
- Factory adjustment certificate
- Wireless charger with 3 different power supply plugs (for the US, EU or UK)
**==> picture [5 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
65 mm<br>**----- End of picture text -----**<br>
80
2022-V2
Applications Water activity
## Water activity probes
Water activity probes **APPLICATIONS** Quality assurance in food manufacturing, coffee processing and the tobacco industry, grain iI storage and pharmaceutical industry. **HC2-AW-USB** ~~——__________—~~ **FEATURES** | • Range of application: 0…1 aw (0…100 %rh) / -40…85 °C • On/Off switch
- USB interface for direct connection to a PC
- Power supply: via USB interface
- Adjusted at 23 °C and 10, 35, 80 %rh
• AW Quick function for fast measurement results (typically 4-5 minutes)
**Order code HC2-AW-USB HC2-AW-USB-SW-1** Feature Measurement probe Probe + software HW5-AW-Code Connection Via USB to PC, 3 m cable HC2-AW-USB Accuracy ±0.008 aw, ±0.8 %rh, ±0.1 K, at 10...30 °C Power supply Via USB interface Filter type Wire mesh filter with 20…25 μm pore size Weight 550 g ~~———~~ ~~
**HC2-AW**
HC2-AW
## **FEATURES**
- Same as HC2-AW-USB, but with UART interface
|**Order code**|**HC2-AW**|
|---|---|
|Feature|Measurementprobe|
|Connection|Via UART,1 m cable|
|Accuracy|±0.008 aw,±0.8 %rh,±0.1 K,at 10...30 °C|
|Power supply|Via displayunit<br>Wire mesh filter with 20…25|
|Filter type|Wire mesh filter with 20…25μmpore size|
|yp<br>Weight|Wire mesh filter with 20…25μp<br>550g|
## **Compatible**
## **Recommended accessories**
- HC2-AW-USB: with PC
- HC2-AW: with laboratory analyzer HygroLab and handheld instrument
## **Delivery package**
- Sample holders WP-14-S WP-40 WP-40TH
- • Calibration device WP-14-S • Calibration standards EAxx-SCS • Disposable sample containers PS-14, PS-40
- Factory adjustment certificate
81
2022-V2
Applications Water activity
## Insertion probes
## **5 / 10 mm for measurements in bulk materials**
## **APPLICATIONS**
- 5 mm insertion probe: dust-free bulk materials such as tablets, grain, jelly capsules and granulates.
- 10 mm insertion probe: dusty bulk materials such as flour, sugar, etc.
## **FEATURES**
- Range of application: -40...85 °C / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
- Standard configuration: 0…1 V = -40…60 °C / 0…100 %rh
- Adjusted at 23 °C and 10, 35, 80 %rh
## **5 mm insertion probe**
|**Order code**|**HC2-P05**|
|---|---|
|Probe type|Ø 5 x 200 mm,insertionprobe with 2 m cable|
|Accuracy|±0.015 aw,±1.5 %rh,±0.3 K,at 10...30 °C|
|Power supply|3.3…5 VDC,adjusted at 3.3 VDC,current: approx. 4.5 mA|
|Filter type|No filter available(laser-cut slots)|
|Response time|<15 s**τ**63|
|Material|Stainless steel DIN 1.4305(probe),POM(handle)|
|Weight|160g|
**==> picture [201 x 255] intentionally omitted <==**
**----- Start of picture text -----**<br>
15<br>25 fi 4<br>5<br>f<br>7<br>5<br>35<br>60<br>131<br>331<br>200<br>**----- End of picture text -----**<br>
## **10 mm insertion probe**
|**Order code**|**HC2-HP28**|
|---|---|
|Probe length|Ø 10 x 280 mm|
|Accuracy|±0.008 aw,±0.8 %rh,±0.1 K,at 10...30 °C|
|Power supply|3.3…5 VDC,adjusted at 3.3 VDC,current: approx. 4.5 mA|
|Filter type|Sintered steel<br>with filter|
|Response time|<20 s,with filter**τ**63|
|Material|Stainless steel DIN 1.4305(probe),POM(handle)|
|Weight|200g|
## **Compatible**
## **Recommended accessories**
- Laboratory analyzer
- HygroLab • Replacement filter HC2-HP28
ET-Z10
## **Delivery package**
- Factory adjustment certificate
82
2022-V2
Applications Water activity ~~PST~~
## Laboratory analyzer AwTherm
With AwTherm, Rotronic offers a professional, high-end laboratory unit for temperature-stabilized measurement of water activity. The wide control range permits measurements to be integrated directly in the tempered manufacturing or storage process.
## **APPLICATIONS**
Food industry, pharmaceutical industry, cosmetics industry
## **FEATURES**
- Highest precision through exact stabilization of temperature
- Wide temperature-control range
- Outstanding repeatability
- Excellent long-term stability
- Reference probe exchangeable for calibration or cleaning
|**General specifications**<br>~~po~~|**General specifications**<br>~~po~~|
|---|---|
|Order code<br>~~po~~<br>~~a~~|AwTherm<br>~~po~~|
|Operatingconditions<br>~~a~~<br>~~a~~|1...40 °C(34...107 °F)|
|Measurement range<br>~~a~~<br>~~a~~|0.005...1.000 aw|
|Accuracy<br>~~a~~<br>~~a~~|±0.005 aw(10...30 °C) /±0.1 °C(±0.18 °F)|
|Power supply<br>~~a~~<br>~~a~~|110...230 V/50...60 Hz|
|Display<br>~~a~~<br>~~a~~|8-line LCD with touch operation|
|Sample sizes<br>~~a~~<br>~~a~~|Variable(14 mm/40 mm)|
|Current consumption<br>~~a~~|≤2 A|
|Temperature control range<br>~~a~~|0...60 °C(32...140 °F)|
|Temperature stability<br>~~a~~<br>~~eePo~~|±0.01 °C/min(±0.018 °F/min)<br>~~eePo~~|
|Chamber-temperaturegradient<br>~~eePo~~|<0.1 °C(<0.18 °F)<br>~~eePo~~|
|**Probe**<br>~~eePo~~<br>~~ae~~||
|Sensor<br>~~ee~~<br>~~ae~~|HYGROMER® IN-1<br>~~ee~~|
|Maintenance/Calibration<br>~~ae~~<br>~~a~~|Annual calibration(recommended)|
|Long-term stability<br>~~a~~<br>~~a~~|<0.01 aw/year|
|Temperature sensor<br>~~a~~<br>~~a~~|PT100,DIN 1/3 Class B|
|**Functions**<br>~~a~~<br>~~Po~~||
|HW5-compatible<br>~~Po~~<br>~~a~~|Yes<br>~~Po~~|
|aw-Quick function<br>~~a~~<br>~~a~~|Yes|
|Interface<br>~~a~~<br>~~a~~|Micro USB|
|Calibration / Adjustment<br>~~a~~<br>~~a~~|**Aw & temperature:**HG2-S (probe removed with AwT-CAL)<br>**Aw:**Rotronic humiditystandards(via HW5)<br>|
|Trend indicator<br>~~a~~|Yes<br>~~Po~~|
|**Approval/ Conformity**<br>~~aPo~~<br>~~Po~~||
|Standards<br>~~Po~~<br>~~a~~|ISO 18787<br>~~Po~~|
|CE/EMC<br>~~a~~<br>~~a~~|EMC 2004/108/EC/IEC EN 61010-1:2010|
|IPprotection<br>~~a~~<br>~~a~~|IP21|
|**Housing / Mechanics**<br>~~po~~||
|Enclosure material<br>~~a~~|PC/ABS|
|Housingdimensions<br>~~a~~|400 x 180 x 180 mm|
|Sample container dimensions<br>~~a~~|AwT-PS14: Ø46 x 14 mm/AwT-PS40: Ø46 x 40 mm|
|Weight<br>~~a~~|4200g|
## **Delivery package**
- AwTherm incl. AwT-MHS
- AwT-PS14 or AwT-PS40
- AC adapter
## **Recommended accessories**
- AwTherm measurement probe
- AwTherm sample holders
- Disposable sample containers
AwT-MHS AwT-PS14 / AwT-PS40 PS-14 / PS-40
- USB cable
- Instruction manual
- HW5-AW-Code
83
2022-V2
Applications Water activity
## Laboratory device HygroLab
The Rotronic HygroLab is an innovative high-end laboratory analyzer for water activity measurements with up to four measurement probe inputs. Simultaneous or asynchronous measurement with the tried-and-tested AW Quick measuring function for pharmaceutical products, tobacco, coffee, food and many more.
## **FEATURES**
- The reliable AW Quick mode for quick results (typical 4 - 5 min)
- 4 probe inputs for simultaneous or asynchrony measurements
|• Standalone laboratory measuring device with 7” touch screen (no additional software<br>necessary)<br>• Remote access with PC or Tablet<br>• Firmware updates over the internet<br>**General specifications**<br>Order code<br>HygroLab<br>Operatingrange<br>0…40 °C(32…104 °F) /0…80 %rh<br>Parameters shown<br>AW,%rh,°C,°F<br>Dimensions<br>215 ×146 ×79 mm<br>Accuracy @23 °C ± 5 %(HC2-AW)<br>± 0.008 aw/0.8 %rh/±0.1 K<br>Long-term stability (HC2-AW)<br>< 1 %rh/ year(Normal conditions)<br>~~__LLLnn~~<br>~~nS~~<br>~~CC~~<br>~~OC—SSTOOOOTOCOCOCOCOCOSC“‘(#SNSNSNCOC*S~~<br>~~C~—SSOOOOOOOCOOCOCOSC“CSCSC“CSNSNCSCNC*S~~<br>~~a~~<br>~~ee~~|||= -<br>.<br>_|= -<br>.<br>_|= -<br>.<br>_|
|---|---|---|---|---|---|
|AWQuick Mode<br>Yes||||||
|146,07 mm<br>78,88 mm<br>214,40 mm<br>Display<br>7” LCD capacitive touch screen<br>Power button<br>Push button(with RGB light indicator)<br>Trend display<br>Yes<br>Clock<br>Real time clock provides a time stamp for every<br>measurement<br>Storage capacity<br>16 GB<br>Power supply<br>12VDC 2.0A 24W Max(AC adapter)<br>Power supply plugs<br>CH(EU) /UK/US<br>Probe connections<br>4 x HC2 station probe<br>(HC2A-S or HC2-AW)<br>USB(A)types<br>2x 2.0 and 2x 3.0<br>USBpower supply<br>5V/500 mA<br>Measurement interval<br>15 s<br>Start-uptime<br>30 s<br>Software update<br>Direct with the HygroLab over the internet<br>Protocols(values)<br>Date,time,AW/RH,°C/°F,AW Setpoint,Serial No.,etc.<br>HW5 compatible<br>No<br>Acoustic alarm<br>No<br>~~ee~~<br>~~a~~<br>~~a~~<br>~~Oe~~<br>~~pf~~<br>|<br>:| |<br>~~a~~<br>cece<br>~~sd ~~_<br>~~a~~<br>~~ns~~<br>~~nS~~||||||
|Calculations<br>Nopsychrometric calculations available<br>**Housing / Mechanics**<br>Housingmaterial<br>Aluminum,ABS,stainless steel<br>~~ns~~<br>~~Do~~<br>~~nS~~||||||
|Weight<br>1.02 kg (2.25 lbs)<br>~~eS~~||||||
|**Conformity with standards**<br>~~Co~~||||||
|CE conform<br>CE 2014/30/EU<br>~~nS~~||||||
|IPprotection rating<br>IP30<br>~~ns~~||||||
## **Compatible**
## **Delivery package**
- Water activity probe
- Humdity probe
- HygroLab
HC2-AW HygroLab HC2A-S • Power adapter
- Pen
- Short instruction manual
84
2022-V2
Applications Water activity
## Handheld instrument HP23-AW-A
In many situations it can be very useful to measure water activity at goods-in, production or storage rooms, e.g. inspection of bulk materials to ensure they meet specifications.
## **APPLICATIONS**
Aw checks of cheese, meat, tobacco, building materials, animal feeds, bakery products, paper, medicines, in horticulture and agriculture, etc.
## **FEATURES**
- Handheld instrument for measurement of water activity, relative humidity and temperature
- AW Quick function for fast measurement results (typically 4-5 minutes)
- Audible alarm to indicate completed measurement
- Saves up to 10,000 data records with %rh, °C, date and time
• Battery charging function
**Order code HP23-AW-A** Probe connections 2 Parameters shown aw / %rh / °C / °F AW Quick function Integrated and via optional HW5 software Calculations All psychrometric calculations available Power supply 9 V battery or 9 V AC adapter via USB-Mini Interfaces USB Range of application 0…1 aW, 0…100 %rh, -10…60 °C LCD 3-line alphanumeric with trend indicator Current consumption Max. 20 mA (with backlight) Dimensions /Weight 188 x 72 x 30 mm / 200 g Material ABS ~~=~~ IP protection IP30 **Compatible Delivery package** • Water activity probe HC2-AW • Short instruction manual • Insertion probes HC2-P05, HC2-HP28 • Battery • All HC2 probes • HW5 ~~So~~ 85
2022-V2
Applications Water activity
## Accessories
## **Sample holders WP-14-S / 40 / 40TH**
## **APPLICATIONS**
The stainless steel sample holders were developed specifically for the water activity probes HC2AW(-USB). There are two sizes available:
- WP-14-S for small samples and for calibration
- WP-40 for larger samples
**==> picture [85 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
WP-14-S<br>WP-40<br>**----- End of picture text -----**<br>
Both products provide excellent sample containment and optimum temperature stability. The WP-40TH can be attached to a water bath for additional control.
|**Order code**|**WP-14-S**|**WP-40**|**WP-40TH**|
|---|---|---|---|
|Use with|PS-14|PS-14/PS-40|PS-14/PS-40|
|Depth|14 mm|40 mm|40 mm|
|Internal diameter|46 mm|46 mm|46 mm|
|Material|V2A steel||Brass,nickel-plated|
|Weight|350g|1250g|1550g|
**Disposable sample containers PS-14 / PS-40 APPLICATIONS** The disposable sample containers ensure the optimum sample volume is filled into the WP-14-S or WP-40 sample holders. They prevent the sample holders from coming into direct contact with the ~~OO~~ product being tested, thereby preventing soiling or cross contamination. The sample containers also provide a convenient means of collecting and storing samples.
|**Order code**|**PS-14**|**PS-40**|
|---|---|---|
|Use with|WP-14-S/WP-40/WP-40TH|WP-40/WP-40TH|
|Depth|14 mm|40 mm|
|External diameter|46 mm|46 mm|
|Unit|100pc.||
**==> picture [22 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
PS-14<br>**----- End of picture text -----**<br>
**==> picture [33 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
WP-40TH<br>**----- End of picture text -----**<br>
**==> picture [22 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
PS-40<br>**----- End of picture text -----**<br>
## **Clamp sealing mechanism**
## **APPLICATIONS**
In the case of very dry or very moist samples additional mechanical sealing of the AW measurement probe and sample holder may be necessary to prevent external conditions influencing the sample.
**Order code AW-KHS** Use with WP-40 / WP-40TH Weight 1100 g ~~—=<=_[_—_ ==~~
86
2022-V2
Applications Meteorology
## Meteorological probe HC2A-S3A
The HC2A-S3A probe is the meteorological probe with a white housing but with a different filter (Wire-mesh filter with 10 µm filter pore size suitable for meteorological applications). It measures relative humidity and temperature and calculates the dew/frost point and is designed for the use in Rotronic meteorological applications.
## **APPLICATIONS**
Meteorology, weather stations, snow cannon
## **FEATURES**
- Accuracy: ±0.8 %rh, ±0.1 K, at 10...30 °C
- Range of application: -50…80 °C[1] * / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
- Standard analog output scaling: 0…1 V = -40…60 °C / 0…100 %rh
|**Order code**|**HC2A-S3A**|
|---|---|
|Probe type|white|
|Dimensions|Ø 15 x 108 mm|
|Range of application|-50…80 °C1,0…100 %rh|
|Accuracy|±0.8 %rh,±0.1 K at 10...30 °C|
|Power supply|3.3…5 VDC,adjusted at 3.3 VDC|
|Current consumption|~4.5 mA|
|Long-term stability|<1 %rh/ year2|
|Sensor type|ROTRONIC HYGROMER®HM1-SK PT100 1/3 Class B|
|Filter type|wire mesh 1.4401,10 um|
|Response time|<15 s,without filter|
|Max. wind velocity|3 m/s,without filter|
|Housingmaterial|Polycarbonate|
|Weight/IPprotection|10g /IP65|
- [1] : The sensor withstands only 60 °Cdp
- [2] : Drift < 1%rh per year with clean air or ismilar (see also pollutant table in the catalogue)
HC2A-S3A
## **Compatible**
## **Recommended accessories**
- Handheld instruments
- Transmitters
- Meteorology transmitters
- Naturally Ventilated Shields
- Actively Ventilated Shields
## **Delivery package**
HP32 HF5, PF4, PF5 MP102H, MP402H AC1000 RS12-T or RS24-T
- Mounting flange AC5005 • Filters • Extension cable 5 m, white E3-05A • Calibration device ER-15 • Humidity standard for calibration 10 %rh EA10-SCS • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS
- Factory adjustment certificate
- Short instruction manual
- Wire-mesh filter
87
2022-V2
Applications Meteorology
## Meteorological probe HC2A-S3/S3H
The HC2A-S3 belongs to the family of HC2A-S probes that form the basis of our product portfolio. It measures humidity and temperature and calculates the dew/frost point. The HC2A-S3H fulfills the highest demands for measuring accuracy.
## **FEATURES**
- Measures relative humidity and temperature, calculates the dew/frost point
- Digital interface (UART) and analog outputs 0…1 V
- Adjusted at 23 °C and 10, 35, 80 %rh (HC2A-S3)
- Adjusted at 23 °C and 10, 20, 30, 40, 50, 60, 70, 80, 90 %rh (HC2A-S3H)
|**Order code**|**HC2A-S3**|**HC2A-S3H**|
|---|---|---|
|Probe type|Meteorology probe,white||
|Range of application|-50…100 °C,0…100 %rh||
|Accuracy|±0.8 %rh, ±0.1 K<br>at 10...30 °C|±0.5 %rh, ±0.1 K<br>at 10...30 °C(10...90 %rh)|
|Power supply|3.3…5 VDC,adjusted at 3.3 VDC||
|Long-term stability|<1 %rh/ year||
|Filter type|Polyethylene standard-filter,40µm,white||
|Response time|<15 s(without filter)||
**==> picture [7 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø 15 mm<br>**----- End of picture text -----**<br>
## **Compatible**
## **Recommended accessories**
- Meteorology transmitters
- Actively ventilated shield
- Naturally ventilated shield
## **Delivery package**
- Factory adjustment certificate
MP102H/402H RS12T / RS24T AC1000
- Polyethylene filter, white (40 µm)
SPA-PE • Connection cable with voltage regulator and 2 m cable, white E3-02XX-ACT/01 • Calibration device ER-15 • Humidity standard for calibration 10 %rh EA10-SCS • Humidity standard for calibration 35 %rh EA35-SCS • Humidity standard for calibration 80 %rh EA80-SCS
- Polyethylene filter
88
2022-V2
Applications Meteorology
## Meteorological probe MP100A / MP400A
Standard meteorology probes with fixed sensors (analog technology).
## **APPLICATIONS**
Weather stations, agriculture, ice warning and snow making systems.
## **FEATURES**
- Very robust, therefore high long-term stability
- Voltage and current outputs for humidity and temperature
- HYGROMER[®] IN-1 Sensor / PT100 1/3 Class B
- Cable length compensation up to 100 m
- Connection with Tuchel T4/T7 connector or fitted cable with open ends
|**Order code**|**MP100A**|**MP400A**|
|---|---|---|
|Output|Voltage output<br>0...1 VDC|Current output<br>0(4)…20 mA|
|Range of application|-40...85 °C/0…100 %rh||
|Power Supply|15...24 VDC|5...24 VDC|
|Accuracy at 10...30 °C|10…95 %rh: ±1.5 %rh<br>Remainingrange: ±2.5 %rh||
|Measurement|Temperature with PT100 - direct or linear output signal||
|Filter|Wire mesh filter ~ 20μmpore size||
**==> picture [142 x 207] intentionally omitted <==**
**----- Start of picture text -----**<br>
_ a<br>40,5<br>210 252<br>HANDLE: WHITE<br>PG7 CONNECTOR HANDLE: WHITE<br>TUCHEL CONNECTOR 7P<br>25<br>30<br>7<br>52<br>**----- End of picture text -----**<br>
## **Compatible**
## **Recommended accessories**
- Actively ventilated shield
- Naturally ventilated shield
## **Delivery package**
RS12T/24T AC1002 / AC1003
- Humidity standard for calibration 10 %rh
- Humidity standard for calibration 35 %rh
- Humidity standard for calibration 80 %rh
- Wire mesh filter
EA10-SCS EA35-SCS EA80-SCS SP-W3-25
- Factory adjustment certificate
- Wire mesh filter
- Instruction manual
89
2022-V2
Applications Meteorology
**==> picture [513 x 309] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data MP100A (analog) MP400A (analog)<br>General<br>Parameters Humidity and temperature<br>Housing material Polyoxymethylene<br>IP protection IP65<br>Weight 120 g<br>Supply voltage 4.8…30 VDC 10...30 VDC<br>Current consumption <4 mA at 4.8 VDC <50 mA at 10 VDC<br>Range of application / Storage conditions -40...85 °C<br>Cable length compensation Up to 99 m<br>Humidity measurement<br>Sensor ROTRONIC HYGROMER® IN-1<br>Measurement range 0..100 %rh<br>Accuracy at 0...30 °C 10…95 %rh: ±1.5 %rh<br>Long-term stability <1 %rh/year<br>Response time <15 s τ 63 (63 % of a jump 35…80 %rh) without filter<br>Temperature measurement<br>Sensor PT100 1/3 Class B<br>Measurement range -50...100 °C<br>Accuracy at 0...30 °C ±0.3 K<br>Response time <15 s τ 63<br>Analog output<br>Current N/A 0(4)…20 mA<br>Voltage 0…1 V N/A<br>Digital output<br>N/A<br>**----- End of picture text -----**<br>
90
2022-V2
Applications Meteorology
## MP102H/402H
## **For interchangeable probe HC2A-S3 / HC2A-S3A**
The MP102H and MP402H are meteorology transmitters with an analog output and RS-485 interface. Humidity and temperature are measured with an interchangeable HygroClip2 HC2A-S3 / HC2A-S3A probe. Temperature measurement can be enhanced by an external PT100 in various accuracy classes.
## **APPLICATIONS**
Weather stations, snow guns, status monitoring of roads, bridges and airports, snow and ice warning systems, research in very remote areas.
## **FEATURES**
- Humidity and temperature measurement with interchangeable HC2A-S3/HC2A-S3A probes (order separately)
- Calculates all psychrometric parameters
- Direct PT100 sensors available as an option
- Voltage or current output signal
- Freely scalable
**==> picture [497 x 298] intentionally omitted <==**
**----- Start of picture text -----**<br>
• High long-term stability ø 3<br>• Service interface (UART) to PCB<br>• RS-485 interface<br>• Connection with cable (3…99 m) with open ends or Tuchel T7 connector<br>Order code MP102H MP402H<br>ø 1 5<br>Output Voltage output Current output<br>0…1/5/10 VDC 0(4)…20 mA<br>Range of application -40..80 °C / 0..100 %rh<br>Power Supply 5...24 VDC 15...24 VDC<br>1<br>With external PT100 Without external<br>PT100<br>ø 2 5 ø25<br>ø 15<br>118<br>108<br>108<br>239 239<br>1 3 1 1 3 1<br>c a . 5 8 c a . 5 8<br>**----- End of picture text -----**<br>
- High long-term stability
- Service interface (UART) to PCB
- RS-485 interface
- Connection with cable (3…99 m) with open ends or Tuchel T7 connector
## **Compatible**
## **Delivery package**
- Meteorology probes
- Actively ventilated shield
- Naturally ventilated shield
- HC2A-S3 / HC2A-S3H / HC2A-S3A RS12T / RS24T AC1003
- Short instruction manual
91
2022-V2
Applications Meteorology
**==> picture [513 x 418] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data MP102H MP402H<br>General<br>Parameters Humidity and temperature<br>Calculates all psychrometric parameters<br>Housing material Polyoxymethylene<br>IP protection IP65<br>Weight 150 g<br>Supply voltage 5...24 VDC 15...24 VDC<br>(0…1 V output)<br>10...24 VDC<br>(0…5 V output)<br>20...24 VDC<br>(0…10 V output)<br>Current consumption <50 mA<br>Application temp. housing / electronics -40...80 °C<br>Cable length compensation Up to 99 m<br>Humidity measurement<br>Sensor ROTRONIC HYGROMER [®] IN-1 (HC2A-S3) / ROTRONIC HYGROMER HM1-SK (HC2A-S3A)<br>Measurement range 0…100 %rh (HC2A-S3(A))<br>Accuracy at 10...30 °C ±0.8 %rh (HC2A-S3(A))<br>Response time <15 s τ 63 (63 % increase 35…80 %rh) without filter<br>Temperature measurement<br>Sensor PT100 1/3 Class B (HC2A-S3(A))<br>Measurement range -50…100 °C (HC2A-S3) / -50...80 °C HC2A-S3A<br>Accuracy at 10...30 °C ±0.1 K (HC2A-S3(A))<br>Response time <15 s τ 63<br>Direct PT100 (optional) PT100 1/3 Class B<br>PT100 1/5 Class B<br>PT100 1/10 Class B<br>Analog output<br>Current N/A 0(4)…20 mA<br>Voltage 0...1 VDC N/A<br>0...5 VDC<br>0...10 VDC<br>Digital output<br>RS-485<br>UART<br>**----- End of picture text -----**<br>
92
2022-V2
Applications Meteorology
## Actively ventilated shields
The ventilated weather and radiation protection shield RS12T with 12 VDC fan and RS24T with 24 VDC fan were developed in close cooperation with MeteoSwiss. This state-of-the-art device reduces the influences of thermal radiation on humidity and temperature measured values to a minimum.
## **APPLICATIONS**
Snow guns, weather stations, agricultural meteorology and building management systems.
## **FEATURES**
- Easy-to-install protection shield with integrated fan
- Special white coating (RAL 9010) minimizes solar heating
- Simple probe mounting
- Suitable for various probes
|**Order code**|**RS12T**|**RS24T**|
|---|---|---|
|Range of application|-30...60 °C||
|Material|Aluminum,POM,RAL 9010||
|Power supply|12 VDC,2 W|24 VDC|
|Fan|Papst fan IP54||
|Ventilation|3.5 m/s/900 l/min.||
|Fan lifetime|At 40 °C ~70,000 h(approx. 8|rox. 8years)|
||||
|**Order code**|**MKRS-HC2**|**MKRS-MP102-402**|
|Use with|HC2A-S3/S3H|MP102H/402H|
|Probe connection|E2 connector|Open ends to terminals|
|Mast diameter|30 - 65 mm||
Further models available on request.
**==> picture [39 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
MKRS-HC2<br>**----- End of picture text -----**<br>
MKRS-MP102-402
## **Compatible**
## **Delivery package**
- Mounting sets
- Installation instructions
93
2022-V2
Applications Meteorology
## Naturally ventilated shields
Naturally ventilated radiation shields are used where the natural ventilation (wind) provides sufficient air flow, e,g, measurement stations in the mountains.
## **APPLICATIONS**
Snow guns, weather stations and building management systems.
## **FEATURES**
- Easy-to-install protection shield for wall and mast mounting
- Multi-plate system for natural ventilation
- Simple probe mounting
- For probe diameters of 15 or 25 mm
- For mast diameters of 25…50 mm
- Protection against wind speeds up to 70 m/s and horizontal precipitation
AC1000 with HC2A-S3/A/SH + E3-05XX
|**Order code**|**AC1000**|**AC1002**|**AC1003**|
|---|---|---|---|
|Mounting probe|Probe screw connection Ø15 mm|Probe screw connection Ø25 mm||
|Use with|HC2A-S3/A/S3H + E3-05A|MP100A/400A|MP102H/402H|
|Number ofplates|9|10|14|
|Mountingshield|Mountingbracket + clampfor mast mounting (Ø 25…50 mm)|||
|Dimensions|Ø130 x 140 mm|Ø130 x 160 mm|Ø130 x 215 mm|
> AC1002 with MP100A-T4 j =H
AC1003 with MP102H
## **Delivery package**
- Installation instructions
- Mounting hardware
94
2022-V2
Applications Cleanrooms
## CRP5 series
The differential pressure measurement of the CRP5 clean room panel is based on diaphragm sensor technology. Thanks to its functionality, this device of the highest Swiss quality can be configured perfectly for the application in question. The CRP5 stands out from the crowd with its front panel manufactured with sturdy glass and removable humidity and temperature probe.
## **FEATURES**
- Designed for cleanrooms
- Removable humidity & temperature probe for simple cleaning
- Accuracy: Pressure ±1.0 %FS, Temperature: ±0.2 K / Humidity: ±1.5 %rh
- Digital communication via Ethernet (Modbus TCP, HW5) and RS-485 (Modbus RTU, HW5)
- Analog and digital inputs
- Front-side pressure connections for room pressure measurement or calibration
- High chemical resistance of glass front panel
- Alarms via relay or color TFT display
- Visual operating elements for operation with protective gloves
## **Power supply**
- Low-voltage: 3-wire
## **Signal output**
- 4 independent current and voltage outputs
- Ethernet (Modbus TCP) / RS-485 (Modbus RTU)
- 6 relay switch contacts
## **Version**
- Panel version with HC2-CRP probe at the front
- Panel version with probe connection at the back
## **Measured parameters**
- Differential pressure, temperature and relative humidity
- Analog and digital input signals
- Psychrometric calculations such as enthalpy, dew point, etc.
## **Measurement ranges**
- -25...+25 Pa / -50…+50 Pa / -100...+100 Pa / -250...+250 Pa / -500…+500 Pa
- -5...60 °C (23...140 °F) / 0...100 %rh
- Analog IN: 0...3.3 V or 0...24 mA (freely scalable)
- Digital IN: 0...1.5 V (low level) / 3.5...24 V (high level)
## **Display**
- Color TFT display with backlight
95
2022-V2
Applications Cleanrooms
## CRP5
## **APPLICATIONS**
Cleanrooms, operating theaters, food industry and applications where very small pressure differences need to be detected. Order code CRP53x Output signals 0...10 V / 4...20 mA (Customer rescaling possible*) 6 x solid-state relays Pressure ranges ±50 Pa / ±100 Pa / ±250 Pa / ±500 Pa Configuration of the • Caps without holes with pressure connections at the back pressure connections • Cap with hole at «+» connection for room pressure measurement • Cap with hole at «–» connection for room pressure measurement Humidity probe Removable probe at the front (HC2-CRP) or probe connection at the back (HC2) Relays 1 A DC / AC 2 A DC ~~—_———~~ & The magnetic HC2-CRP humidity and temperature probe can also be used independently.
CRP5 with HC2-CRP probe
**==> picture [116 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
75<br>s © e<br>160 10 20<br>180 4 48<br>4,3<br>Ø<br>51<br>280 300<br>10<br>**----- End of picture text -----**<br>
~~{HEP~~ ° t ~~t~~ 235 ~~dl~~ 34 ~~s~~ © ~~e~~ 160 10 20 180 4 Flush mount probes The flush mount probe is mounted in the walls of glass cabinets, showcases, gallery walls, al W laboratories and in cleanrooms for humidity and temperature measurement. HC2-IS25, steel filter, cover **Order code HC2-IS25** ø32 Accuracy ±1.5 %rh, ±0.2 K, at 0…90 %rh and 10...30 °C ø27 Power supply 3.3…5 VDC, adjusted at 3.3 VDC, current: ~4.5 mA Filter type Sintered steel (3/4") Sensor type ROTRONIC HYGROMER[®] WA-1, PT100 1/3 Class B Response time <20 s ~~|~~ ø17 Housing material Polycarbonate, stainless steel DIN 1.4301 ø15 Weight 50 g ~~[ea[fe=[a] == cei~~ ø15 **Compatible Recommended accessories** • HW5 • Service cable AC3006 / AC3009* • Calibration accessories **Delivery package** • HC2A-S probes
- Service cable AC3006 / AC3009* • Calibration accessories • HC2A-S probes
- Factory adjustment certificate
- Short instruction manual
- Requires optional HW5 software and service cable.
96
2022-V2
Applications Cleanrooms
**==> picture [513 x 529] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data CRP53x<br>General<br>Parameters Differential pressure, temperature, relative humidity, absolute pressure, digital and analog<br>inputs<br>Housing material Front: glass<br>Back: stainless steel<br>IP protection Front: IP65 (also with detached probe)<br>Back: IP20<br>Mounting position Wall mounting<br>Dimensions 180 x 300 x 72 mm<br>Weight 1,700 g (with humidity probe)<br>1,550 g (without humidity probe)<br>Display Color TFT display<br>Menu navigation 4 optical keys<br>Electrical connections Screw terminals at the back<br>Power supply 20…48 VDC / 16…35 VAC<br>Current consumption <450 mA<br>Range of application / Storage conditions -5...60 °C (23...140 °F) / 0…100 %rh<br>Firmware update Via HW5 software<br>Service interface UART<br>CE / EMC compatibility EMC Directive 2014/30/EU<br>Fire protection class Corresponds to UL94-HB<br>Differential pressure measurement<br>Measurement principle Diaphragm sensor<br>Measurement ranges ±50 Pa / ±100 Pa / ±250 Pa / ±500 Pa<br>Medium Air and non-aggressive gases<br>Accuracy at 23 °C ±3 K ±1.0 %FS<br>Zero drift Compensated (manual or automatic zero adjustment)<br>Measurement interval 1 s<br>Pressure resistance 0.7 bar (70,000 Pa)<br>Pressure connections Front: tubing connector Ø 6 mm x 10 mm<br>Back: tubing connector Ø 4 mm x 10 mm<br>Measurement of temperature and relative humidity<br>Probes HC2-CRP, HC2<br>Measurement range -100...200 °C (probe dependent) / 0...100 %rh<br>Outputs<br>Analog outputs 4, freely configurable<br>Analog output type 0 / 4...20 mA or 0...1 / 5 / 10 V<br>Switch output 6 solid-state relays<br>Switching capacity <50 VDC at <2A if polarity is considered<br><35 VAC at <1 A if polarity is not considered<br>Accuracy analog output ±5 mV (voltage output)<br>±20 μA (current output)<br>Permissible load >10 k Ω (voltage output)<br><500 Ω (current output)<br>Digital communication Ethernet (Modbus TCP, HW5) / RS-485 (Modbus RTU, HW5)<br>**----- End of picture text -----**<br>
97
2022-V2
Applications ATEX
## HygroFlex5-EX series
The HygroFlex5-EX series is the latest development in two-channel transmitters for precise measurement of humidity and temperature in dust and gas potentially explosive atmospheres. The interchangeable probes are cast into a stainless-steel tube and certified for operation in Zone 0/20. The transmitter itself is certified for Zone 1/21. The intelligent design of the circuitry with electrical isolation permits the measuring system to be operated without an intrinsically safe power supply for many applications.
## **FEATURES**
- Measurement of relative humidity and temperature
- Optional output of dew point and other psychrometric calculations
- Safe operation in potentially explosive environments
- Electrically isolated analog outputs
- No intrinsically safe power supply required
- Interchangeable stainless steel probes
- Certified for two temperature classes (T4 / T5)
## **Power supply**
- Low-voltage: 2-wire
## **Signal output**
- Current output
## **Versions**
- Wall mount (W)
- Duct mount (D)
## **Measured parameters**
- Relative humidity and temperature
## **Measurement ranges**
- 0...100 %rh
- -40...60 °C / -40...85 °C
## **Display**
- Display with trend indicators and keypad
- Without display
98
2022-V2
Applications ATEX ~~ST~~
## HF5-EX duct / wall version
## **APPLICATIONS**
**==> picture [512 x 452] intentionally omitted <==**
**----- Start of picture text -----**<br>
Storerooms, pharmaceutical / biotechnology industry, sugar and flour mills, power stations, oil<br>industry.<br>Order code HF520-EX-x<br>Output parameters Relative humidity / Temperature / Psychrometric<br>calculation<br>Display Optional (without backlight)<br>Humidity probe Interchangeable HygroClip2-EX probes<br>ne<br>Wall version (W)<br>HF5-EX probes 160<br>HC2-SM-EX HC2-SM-EX<br>Wall mounting Duct mounting<br>Non-explosive area<br>Cable gland<br>AC1301-MEX<br>Probes<br>HC2-SM-EX<br>160<br>Probes<br>HC2-SM-EX 30<br>Zone 0/20 Zone 1/21<br>Bi<br>HC2-IMxxx-EX HC2-IExxx-EX / HC2-LDPxxx-EX<br>Cable probe for flexible installations Screw-in cable probe for pressure lines or low<br>dew point Duct version (D)<br>Non-explosive area Non-explosive area<br>235 61<br>Probes<br>HC2-IMxxx-EX<br>a |<br>100<br>100<br>210 25<br>Non-explosive area 110<br>Zone 1/21 61<br>25 25<br>**----- End of picture text -----**<br>
**==> picture [95 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
Non-explosive area<br>Probes<br>HC2-IMxxx-EX<br>2/5/10 meters of cable<br>130/275 mm probe<br>Cable gland<br>AC1301-MEX<br>Zone 0/20<br>Zone 1/21<br>**----- End of picture text -----**<br>
**==> picture [267 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
Non-explosive area<br>a 235 61<br>160<br>Probes 30<br>HC2-IExxx-EX/HC2-LDPxxx-<br>EX<br>2/5/10 meters of cable<br>½” G/NPT thread<br>Zone 0/20<br>61<br>25<br>Zone 1/2<br>**----- End of picture text -----**<br>
## **Compatible**
## **Recommended accessories**
- HW5
- Service cable
AC3006*
- Calibration accessories
## **Delivery package**
- Replacement filters
- Cable gland AC1301-MEX for mounting in ducts
- Factory adjustment certificate, short instruction manual
- Screws for mounting
- Requires optional HW5 software and service cable.
99
2022-V2
Applications ATEX
**==> picture [513 x 579] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data HF520-EX<br>General<br>Parameters Humidity and temperature<br>Calculated parameters All psychrometric parameters<br>Housing material Aluminum (DIN EN 1706 EN AC-AlSi 12 (Fe))<br>IP protection IP66<br>Weight Wall version: 1,030 g<br>Duct version: 1,140 g<br>Startup time Standard cold <60 s / warm <30 s<br>Measurement interval 20…240 s<br>Display Optional, LCD without backlight<br>Electrical connections Connections: Ex-e terminals (0.2…2.5 mm2)<br>Cable gland: M16 x 1.5 (Ø cable 4.5…7 mm)<br>Power supply 10...28 VDC<br>Current consumption 2x24 mA startup / 2x20 mA operation<br>Application temperature housing / electro- -40…60 °C without display<br>nics -10…60 °C with display<br>Service interface UART internal service interface (only outside the explosive zone)<br>CE / EMC compatibility EMC Directive 2014/30/EU<br>ATEX directives 2014/34/EU (ATEX)<br>EX identification II 2(1) G Ex eb mb [ia Ga] IIC T5 Gb<br>II 2(1) D Ex tb [ia Da] IIIC T80°C Db<br>Analog output<br>Number 2<br>Current 4…20 mA, two-core<br>Galvanic isolation Yes<br>Maximum load 500 Ω<br>Accuracy at 23 °C <20 µA<br>Technical data HC2-SM-EX / HC2-IM-EX / HC2-IE-EX / HC2-LDP-EX<br>General<br>Parameters Humidity and temperature<br>Housing material / IP protection Stainless steel (1.4301) / IP66<br>Cable probes 2/5/10 meters<br>EX identification II 1/2 G Ex ia IIC T5...T4 Ga/Gb<br>II 1/2 D Ex ia IIIC T80 °C ...T110 °C Da/Db<br>Humidity measurement<br>Sensor HC2-SM/IM/IE-EX: ROTRONIC HYGROMER [®] IN-1<br>HC2-LDP-EX: ROTRONIC HYGROMER [®] LDP-1<br>Adjustment Not via device menu (only outside the explosive zone with HW5 + AC3001)<br>Measurement range 0…100 %rh<br>Accuracy at 23 °C 0.8 %rh<br>Temperature measurement<br>Sensor HC2-SM/IM/IE-EX: PT100 1/3 Class B<br>HC2-LDP-EX: PT1000 1/3 Class B<br>Measurement range -40…60 °C / -40...85 °C<br>Accuracy at 23 °C 0.1 K<br>Accessories<br>Filter SP-FN15, sintered steel filter (1.4401)<br>Cable gland AC1301-MEX for duct mounting and cable probes (IM)<br>**----- End of picture text -----**<br>
100
2022-V2
**==> picture [514 x 463] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Humidity and Temperature|
|Temperature|
|Differential pressure|
|©|
|CO2|
|Applications|
|Rotronic Monitoring System – RMS|
|ee|(3)|
|Software|
|EcoLine – Humidity & Temperature|
|Services|
|Theory|
**----- End of picture text -----**<br>
**Video Universal RMS** Interested? Then scan the QR code!
101
2022-V2
RMS Introduction
## RMS – For every application
The Rotronic Monitoring System is a modular system of hardware elements and software. It guarantees maximum flexibility at installation time, and ensures excellent availability of the data during operation. The data loggers record all measurements by Rotronic and third-party sensors and transmit them to the database. It stores all information and makes it available to all users, regardless of whether they access the database by PC, Mac, tablet or smartphone.
## Data flow
## **Input transducers**
The data loggers read out Rotronic measuring instruments or other input transducers such as cameras or third-party sensors. In this way the RMS monitors various parameters, both from Rotronic and third-party products.
- Rotronic measuring instruments
**mA V** ~oO ft
- Digital measuring instruments from other suppliers
- Analog instruments from other suppliers
## **Data logger**
The data logger stores all measured data and sends it to the database. Should the connection be lost, the logger stores the data internally to protect data integrity and fills the data gaps when the connection has been restored.
- Automatic internal storage
- Backfilling of data gaps
- Wireless/LAN interface
## **Software / Database**
The database covers the complete monitoring system. It contains all the measured values of the system and saves all actions. The server or cloud software alerts the relevant users in the case of problems and manages the user-specific access rights.
- SQL database
- Cloud solution can be validated
- On-premis/Server solution can be validated
## **Output size**
The database can be accessed with smartphones, tablets and all PCs with a web browser. Visualization and alerting are therefore possible worldwide and on all common platforms.
- Real-time monitoring
- Supports all common browsers
102
2022-V2
RMS Introduction
## Network environment
**==> picture [491 x 688] intentionally omitted <==**
**----- Start of picture text -----**<br>
RMS SaaS Data access<br>Hosted software / database<br>se Internet w s ~<br>IT Security Firewall Firewall<br>Router<br>ISO27001 compliant<br>Mobile networkSmartphone N @) on<br>Firewall<br>oz) =<br>Service Provider<br>Phone alarm : a<br>SMS<br>Alarming & Reporting Wireless network*<br>* via API<br>—<br>@ CSV<br>ao (N) S@&<br>Production and/or storage site<br>Router LAN<br>Ethernet Ethernet<br>RMS On-premise<br>Local software /<br>Database<br>Mini<br>Logger<br>Wall Logger Wireless<br>Gateway<br>3rd Party software*<br>* via API and<br> OPC<br>Output / input Light /<br>module buzzer Wall Logger<br>mp<br>Regulations<br>DIN rail<br>‘ = :| e —_— RMS converter ®<br>logger for Rotronic devices<br>CRP5 HF5<br>Din rail cabinet<br>y RMS converter for<br>non RMS devices<br>Particle Various IP Cameras (Modbus TCP)<br>Gimp counter r digital<br>Sensors<br>WiFi 868/915 MHz Cellular LoRa/Sigfox<br>IT risk<br>certified<br>**----- End of picture text -----**<br>
103
2022-V2
RMS Software
## Monitoring software
The RMS Software fulfills all requirements for server-based monitoring. The software is linked to a database that archives all the measured data and actions of the system. The data can be accessed from anywhere in the world via all common platforms as long as an internet connection is available.
## **Data history always available**
The database allows access to all historical data at any time, thereby ensuring traceability according to FDA and GMP. This data can be put together into a complete PDF report quickly, automatically and easily.
- Chart
- Table
- Layout
- Dashboard
- Events (audit trail)
- Analysis
- Reporting (PDF & CSV)
## **Alarms**
Whether by voice call, email, SMS or switching of an alarm relay: the RMS offers clear alarm functions and records all events in the database:
- Errors
- Warnings
- System messages
- Reminders
- Alarms
## **Validation at the touch of a button**
RMS enables validation at the touch of a button. The system checks data integrity automatically by self-test in that it switches all input modules into their various states and checks the alarms that are meant to be triggered. The software then generates a validation report on the complete system.
- The validation documents comply with GAMP5 requirements (see Rotronic Validation Guide on the Rotronic website)
## **Easy user management**
**==> picture [166 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
Alarms<br>c h<br>smartphoneTablet PC DB/Server Software Data Logger<br>Data Center<br>SNMP / HTTP<br>OPC<br>User<br>Account<br>CO)<br>**----- End of picture text -----**<br>
The intelligent user management function makes it possible to assign different rights to every user on the basis of data groups. For example, the same user can have only read rights in data group A, while he also has write rights in data group B.
## **Data analysis**
To analyze your data, you can generate reports at any time. These reports can be visualized and formatted at will.
- Charts and tables (PDF or CSV)
- Statistical data (min./max./average/standard deviation)
- MKT: mean kinetic temperature
- Audit trail
104
2022-V2
RMS Software
## RMS software products
The RMS software was developed on the basis of FDA and GAMP5 guidelines.
**==> picture [513 x 227] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type RMS On-premise RMS Cloud/SaaS<br>(SaaS – Software as a Service)<br>Version<br>Chart & table view <br>Layout view <br>Dashboard view <br>Data archiving <br>Audit trail <br>Calibration/Adjustment <br>Validation <br>Alarm scheme ∞ ∞ 40 200 200<br>Users (freely extendable) 2 5 10 1 20 2 5 10 10<br>Devices or measuring points 10 40 100 2 ∞ 10 40 100 100<br>(freely extendable)<br>Storage (freely extendable) ∞ ∞ ∞ 12 months 12 months 12 months ∞<br>Basic Professional Enterprise Free Ind Small Professional Enterprise Exclusive<br>**----- End of picture text -----**<br>
105
2022-V2
RMS Hardware
## RMS-HCD
This digital probe is characterized by its high performance. Very low current consumption, the highest degree of accuracy and measurement results within 50 ms are its main features. This is enabled by the new AirChip4000, which together with the HYGROMER[®] HT-1 sensor forms a powerful combination.
## **FEATURES**
- Measures relative humidity and temperature
- Outstanding accuracy, repeatability and long-term stability
- Advanced probe housing and construction
- Compatible with RMS data loggers and RMS software
- Low power consumption
|**General specifications**|**General specifications**|**General specifications**|
|---|---|---|
|Order code|RMS-HCD-S (black)<br>RMS-HCD-S3(white)|RMS-HCD-IC102<br>(Industrialprobe,2 m cable)|
|Humiditysensor|HYGROMER HT-1||
|Temperature sensor|PT1000,Class 1/3 B|PT 100,Class 1/3 B|
|Operatinghumidity|0…100 %rh<br>~~es~~||
|Operating temperature<br>~~ee~~|-40…+85 °C<br>~~ee~~<br>~~es~~|-40…+85 °C (Electronics)<br>-100…200 °C1 (Sensor head)<br>~~ee~~|
|Accuracy @23 °C|±0.8 %rh ±0.1 K<br>~~es~~||
|Long-term stability|1 %rh/ year||
|Startuptime|50 ms|90 ms|
|Measurement interval|500 ms||
|Response time sensor|t63: <15 s without filter, (temperature and humidity)||
|Maximum wind velocity|3.5 m/s without filter||
|Supplyvoltage|2.8...5.5 VDC|3.3...5.5 VDC|
|Current consumption|0.5 mA|<3 mA|
|Digital interface|UART||
|Protocol|Modbus RTU||
|**Standards**|||
|Compliance|FDA 21 CFR Part 11/GAMP5||
|**Housing / Mechanicalparts**|||
|Material<br>Protection ratin|PC,PPS,stainless steel 1.4301<br>IP65()||
|Protection rating|IP65(except sensor area)||
|Weight|10g|230g|
- 1 Peak load: 100 h. Maximum permissible continuous load: 190 °C
**==> picture [41 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
RMS-HCD-S<br>**----- End of picture text -----**<br>
**==> picture [57 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
RMS-HCD-IC102<br>**----- End of picture text -----**<br>
**==> picture [122 x 207] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø 15 mm<br>r o}<br>144 mm<br>108 mm<br>111 mm<br>Ø 15 mm<br>**----- End of picture text -----**<br>
## **Compatible**
## **Delivery package**
- RMS-LOG-L / RMS-LOG-868 / RMS-LOG-915
- AC3001
- HygroClip DIGITAL
- Short instruction manual
- Calibration certificate
106
2022-V2
RMS Hardware
## RMS-TCD-S-001
The RMS-TCD-S-0001 digital probe was designed for all temperature applications where accuracy and interchangeability are crucial. The temperature probe is attached to a 2m cable to ensure flexibility and ease of use during calibration.
## **FEATURES**
- Measures temperature
- Outstanding accuracy, repeatability and long-term stability
- Advanced probe housing and construction
- Compatible with RMS data loggers and RMS software
- Low power consumption
- Digital communication
- Hot swap possibility, ensuring little to no downtime
- Automatic serial number replacement documented within the RMS audit trail
|**General specifications**<br>~~Cn~~<br>~~PC~~|**General specifications**<br>~~Cn~~<br>~~PC~~|
|---|---|
|**ecifications**<br>Order code<br>~~Cn~~<br>~~PCa~~|RMS-TCD-S-001|
|Measurement range<br>~~PCa~~<br>~~Pe~~|-200...200 °C|
|Accuracy<br>~~Pe~~|±0.25 °C at -50…85 °C|
|Longterm stability<br>~~Pe~~|±0.5 °C/year|
|T63<br>**Electronics details**<br>~~PT~~|90 s<br>~~PT~~|
|**Electronics details**<br>~~PT~~||
|Temperature range<br>~~PT~~|-40…85 °C<br>~~PT~~|
|Relative humidityrange<br>~~PT~~<br>~~a~~|0…100 %rh<br>~~PT~~|
|**Housing details**<br>~~a~~||
|Material<br>~~ee~~|Polycarbonate<br>~~ee~~|
|Housing potting<br>~~ee~~<br>~~PT~~|Yes<br>~~ee~~<br>~~PT~~|
|Diameter<br>~~ee~~<br>~~PT~~|Ø15 mm<br>~~ee~~<br>~~PT~~|
|Length<br>~~ee~~<br>~~PT~~<br>~~Ce~~|110 mm<br>~~ee~~<br>~~PT~~|
|IP Rating<br>~~ee~~<br>~~PT~~<br>~~Ce~~|IP65<br>~~ee~~<br>~~PT~~|
|Connector<br>~~ee~~<br>~~PT~~<br>~~Ce~~<br>~~as~~|Standard Rotronic 7-pin connector<br>~~ee~~<br>~~PT~~<br>~~as~~|
|**Sensor details**<br>~~ee~~<br>~~PT~~<br>~~as~~<br>~~|~~<br>~~a~~||
|Temperature sensor<br>~~ee~~<br>~~PT~~<br>~~a~~<br>~~Ce~~|4 wire PT100 Class A(DIN EN 60751)<br>~~ee~~<br>~~PT~~<br>~~a~~|
|Material<br>~~ee~~<br>~~a~~<br>~~Ce~~|Stainless steel – austenitic – 1.4571(316Ti)bar<br>~~ee~~<br>~~a~~|
|Sensorpotting<br>~~Ce~~|Yes|
|pg<br>Diameter|Ø3 mm|
|Length|50 mm|
|g<br>IP Rating|IP68|
|Battery lifetime|RMS-LOG-868/915/L: @60 s 240 d<br>RMS-LOG-L-D:@60s 18 d|
|**Cable details**||
|Material|Perfluoroalkoxyalkanes(PFA)|
|Diameter|Ø2.2 mm|
|Length|2 m|
|Temperature range|-190...200°C|
|**Technical details**||
|Communication|MODBUS RTU|
|Output signal|UART|
|Power supply|3.3…5 V|
|Current consumption|~3.8 mA|
|Adjustment option 1<br>~~a~~|2point user adjustmentpossible<br>B and C coefficients|
|Adjustment option 2<br>~~a~~<br>~~as~~|A,B and C coefficients<br>~~as~~|
|**Accessories**<br>~~as~~<br>~~Ce~~||
|Hardware<br>Software<br>~~Ce~~<br>~~a~~|AC3001,RMS-LOG-L,RMS-LOG-868/915,RMS-LOG-L-D<br>~~Ce~~|
|Software<br>~~a~~<br>~~Ct~~|RMS-CONFIG;Rotronic MonitoringSystem<br>~~Ct~~|
## **Compatible**
## **Delivery package**
- RMS-TD-0001
- AC3001
- RMS-TCD-S-001
- Calibration Certificate
- RMS-LOG-L/868/915
107
2022-V2
RMS Hardware
## RMS-PCD-S-XXX
The Rotronic differential pressure probes are ideal for clean rooms, operating theaters and applications where even minor differences in pressure can have a big effect. Thanks to our two different measurement methods (thermal mass flow measurement and diaphragm measurement), we offer the perfect solution for every requirement. Together with other measurement parameters, these probes can be integrated in RMS perfectly.
## **FEATURES**
- High-precision measurement and long-term stability
- With ambient pressure compensation
- Large overload range
|**General specifications**<br>Sensor type<br>Thermal Mass Flow<br>Membrane<br>Accuracy1at 23 °C ±3 K<br>±1% FS<br>±1% FS2<br>~~a~~||CS|
|---|---|---|
|Long-term stability3<br>±0.1% FSS/year<br>±2% FSS/year for ±25Pa probe<br>±1% FSS/year for ±50Pa probe<br>±0.5% FSS/year for ±100Pa probe<br>±0.25% FSS/year for ±250Pa and||Ø 32 mm|
|±500Paprobes|||
|Zero point<br>compensation4<br>Automatic, 1x per<br>measurement interval<br>Manual, with external tube;<br>via RMS software1<br>Medium<br>Air<br>Air & non-aggressivegases<br>Ambient pressure<br>compensation<br>Automatic<br>Not necessary<br>Adjustment and<br>calibration<br>Factory adjustment/calibration: 5 points<br>Customer adjustment: max. 9points<br>Measurement range<br>-25...+25Pa/-50…+50Pa/-100...+100Pa/-250...+250Pa/-500…+500Pa<br>Burstpressure<br>5 bar<br>0.7 bar<br>Leak rate<br><180µl/min.<br>0µl/min.<br>Startuptime<br><0.5 s<br>~~ee~~<br>~~a~~<br>~~a~~<br>~~ee~~<br>~~es~~<br>~~ee~~<br>~~a~~<br>~~OO~~<br>~~OO~~<br>~~nO~~||87 mm<br>76 mm|
|Measurement interval<br>1 sprobe/≥10s RMS/1s Modbus<br>~~a~~|||
|Response timet63<br><1 s<br>~~a~~|||
|Range of application<br>-20…+80°C (0…+70°C temp.-comp.)<br>0…95 %rh non-condensing<br>Voltage<br>3.3 – 5.5 V<br>Current consumption<br>30 mA(avg.)<br>12 mA(avg.)<br>~~ee~~<br>~~a~~<br>~~OO~~|||
|Batterylife LOG-868/915 350d@60s interval<br>650d@60s interval<br>~~a~~|||
|Batterylife LOG-L<br>395d@60s interval<br>840d@60s interval<br>~~a~~|||
|Protocols<br>Modbus RTU<br>~~a~~|||
|**Standards**|||
|Compliance<br>FDA 21 CFR Part 11/GAMP5<br>**Housing / Mechanicalparts**<br>Housing material<br>Polycarbonate (housing)<br>Stainless steel DIN 1.4305(nuts,connectors)<br>Fireprotection class<br>Corresponds to UL94-HB<br>Dimensions<br>Ø 32 mm x 87 mm<br>~~aee~~<br>~~a~~<br>~~a~~|1<br>2|Please see the device manual for detailed considerations.<br>For maximum accuracy, Rotronic recommends strongly to<br>perform a zero point compensation after the installation<br>and initial operation and to repeat it annually. For<br>aggressive environments / gas media, a more frequent<br>zero point compensation is advised. Please see the<br>device manual for detailed considerations.|
|Pressure connections<br>Tubingconnector internal Ø 4 mm x 10 mm<br>~~a~~|3|Highly reducible by a zero point compensation of the|
|Weight<br>60g<br>IPprotection class<br>IP65<br>~~a~~<br>~~a~~|4|RMS-PCD-S-Mxx (membrane sensor).<br>A zero point adjustment is recommended for every<br>installation or position change.|
|**Compatible**<br>**Delivery package**|||
|• RMS-LOG<br>Wireless ≥V1.5/LAN data loggers ≥V1.4<br>• Differential pressure probe<br>• Calibration certificate<br>• Short instruction manual<br>• Wall-mounted holder<br>• Short pressure tube internal Ø 4mm x 10cm (PCD-S-Mxx only)|||
108
2022-V2
RMS Hardware
## CCA-S-20X-SET
The CCA-S-20X is an analog probe with NDIR technology for measurement of carbon dioxide (CO2). Developed with a pyroelectric infrared detector with dual temperature compensation and an integrated semiconductor temperature sensor to maximize accuracy and minimize drift. The signal is converted to 4...20 mA by the converter with power supply (CCA-S-20X-SET).
## **FEATURES**
- Measures from 0 to 20 %CO2
- Suitable for incubators: 37 °C, 95…98 %rh and 5 %CO2
- Interchangeable probes
• ±0.1 °C accuracy in measurement range **General specifications** Measurement principle Infrared (NDIR) Measured parameter Carbon dioxide concentration (%) Accuracy ±10 % of measured value Medium Air & non-aggressive gases Long-term stability ±0.24 %CO2/year Ø 32 mm Temperature dependence ±10 % of measured value Pressure dependence ±0.15 % of measured value/hPa Measurement range 0…20 %CO2 Application range -20…50 °C / 0…100 %rh, 700…1200 hPa Storage conditions -20...30 °C / 0...95 %rh Startup time 60 s Power supply CCA-S-20X: 3...5 VDC / 80 mA CCA-S-20X-Set: 24 VDC / 150 mA AC adapter requirements 100…240 VAC / 50…60 Hz / 0.3 A Output signal 4...20 mA (CCA-S-20X-SET) 0.4...2.0 V (CCA-S-20X only sensor) **Conformity with Standards** FDA / GAMP directives FDA CFR21 Part 11 / GAMP 5 **Housing / Mechanical parts** Enclosure material Polycarbonate (housing) Stainless steel DIN 1.4305 (nut) Fire protection class Corresponds to UL94-HB Dimensions Sensor: 32 mm x 87 mm Converter box: 100 mm x 77 mm x 40 mm (LxWxH) IP protection class IP40 Weight 55 g sensor ~~—;~~ 200 g converter box oy Fig.: CCA-S-20X-SET **Compatible Delivery package** • Analog Input RMS-MADC-868/915-A • CCA-S-20X RMS-ADC-L-R • Power supply • CO2 Sensor CCA-S-20X • Converter box • RMS On-Premise RMS-WEB • E2-01XX • RMS SaaS solutions RMS-CLD ~~oo~~ 109 2022-V2
RMS Hardware RMS Wall Data Logger The data logger is the flexible component between the probe and the database in the Rotronic Monitoring System. It stores 44,000 pairs of measured values and transmits them to the RMS database via LAN or wireless link. It guarantees absolute data protection, even if power supply and communications should break down temporarily. **FEATURES** • 44,000 data point memory • Fail-safe, thanks to internal battery —— | • Wireless or LAN interface **General specifications** Measured parameters Humidity & temperature, CO2, differential pressure, LDP Range of application -40..70 °C / 0..100 %rh Storage conditions -40..30 °C / 0..95 %rh Maximum altitude 2000 m ASL Power supply 24 VDC ±10 % / <100 mA / Battery: RMS-BAT (2xAA, LiSocl2) / PoE: 802.3af-2003, Class 1 AC adapter requirements 24 VDC ±10 % / 4 W nominal / <15 W power-limited Battery life 3 years (at 23 °C, measurement interval 1 min., HCD-S probe) **Device data** Measurement interval 10 s to 15 min. Startup time < 10 s Order code RMS-LOG-L RMS-LOG-868 RMS-LOG-915 Interfaces Ethernet ISM 868 MHz ISM 915 MHz Indoor wireless range - 20..50 meters 15..25 meters Protocols HTTP / MODBUS TCP Ethernet cable requirement Min. Cat. 5, SFTP, max. 30 m **Conformity with standards** FDA / GAMP directives FDA CFR21 Part 11 / GAMP 5 **Housing / Mechanics** Housing material ABS Fire protection class UL94 –V2 105 mm Dimensions 105 x 113 x 38 mm IP protection class IP65 ~~=_~~ Weight 200 g ~~r~~ 38 mm **Compatible Delivery package** • HygroClip DIGITAL HCD/PCD/CCD • Data logger
HCD/PCD/CCD RMS-GW-868/915 RMS-WEB RMS-CLD
- 2 batteries
- RMS Gateway
- RMS On-premises software
- Wall bracket
- Short instruction manual
- RMS SaaS solutions
- 2 screws & 2 plugs
110
2022-V2
RMS Hardware
## RMS Data Logger with Display
The RMS-LOG-L-D stores up to 44,000 pairs of measured values and transmits them to the RMS database via LAN link. Thanks to its autonomous operation, the logger can display current readings as well as visual and audible alarms even if the power supply and communication should fail temporarily.
## **FEATURES**
- 44,000 data point memory
- Visual and audible alarms
- Autonomous operation on failure
- Redundant power supply
|**General specifications**<br>~~[oo~~|**General specifications**<br>~~[oo~~|**General specifications**<br>~~[oo~~||
|---|---|---|---|
|Measurement interval<br>~~[oo~~<br>~~a~~<br>~~a~~|10 s to 300 s|||
|Startuptime<br>~~a~~<br>~~a~~|< 10 s|||
|Software compatibility<br>~~a~~<br>~~a~~|≥ V1.3.0,from V2.1 all functions<br>|||
|Application range<br>~~a~~|-20…70 °C,non-condensing<br>|||
|Storage conditions<br>~~aPT~~|-20…30 °C,non-condensing<br>~~PT~~|||
|Maximum altitude<br>~~PT~~<br>~~PT~~|2000 m ASL<br>~~PT~~<br>~~PT~~|||
|Power supply<br>~~PT~~<br>~~PO~~<br>~~_~~|24 VDC ±10%/Battery: RMS-BAT(2xAA,LiSocl2)<br>~~PT~~<br>~~PO~~<br>|||
|Current consumption max.<br>~~PO~~<br>~~_~~|50 mA<br>~~PO~~<br>|||
|AC adapter requirements<br>~~_a~~<br>~~a~~|24 VDC ±10%,4 W minimum,> 5 W Limited Power Source<br>~~a~~|||
|PoE<br>~~_a~~<br>~~a~~|802.3af-2003,Class 1<br>~~a~~|||
|**Device data**<br>~~a~~<br>~~PT~~<br>~~a~~||||
|Order code<br>~~PT~~<br>~~a~~|RMS-LOG-L-D<br>~~PT~~|||
|Ethernet cable requirement<br>~~a~~<br>~~CO~~|Min. Cat 5,SFTP,max. 30 m<br>~~CO~~|||
|Interface<br>~~a~~<br>~~CO~~<br>~~a~~|Ethernet<br>~~CO~~|||
|Protocols<br>~~a~~<br>~~a~~<br>~~eS~~|HTTP/Modbus TCP<br>~~eS~~|||
|Number of measuring points<br>~~a~~<br>~~eS~~<br>~~ns~~<br>~~————Pp~~|2<br>~~eS~~<br>~~ns~~<br>~~Pp~~|||
|Battery life<br>(@60 s and 600 s interval)<br>~~a~~<br>~~ns~~<br>~~————Pp~~<br>~~Se~~|HCD-S/HCD-IC: 7 d<br>~~ns~~<br>~~Pp~~|||
||CCD-S-XXX: 2.4 d<br>~~Pp~~|||
||PCD-S-XXX: 15 d<br>~~Pp~~|||
|HCD-S/HCD-IC<br>~~————Pp~~<br>~~Se~~|7 d<br>~~Pp~~|||
|CCD-S-XXX<br>~~Se~~<br>~~a~~<br>~~a~~|2.4 d<br>|||
|PCD-S-XXX<br>~~a~~<br>~~aEO~~|15 d<br>|||
|Storage capacity<br>~~aEO~~<br>~~es~~|44,000 datapoints<br>|||
|**Conformity with standards**<br>~~EOCd~~<br>~~es~~||||
|Solderingmaterial<br>~~es~~<br>~~EO~~|Lead free/RoHS conformity<br>|||
|FDA/GAMP directives<br>~~es~~<br>~~EO~~|FDA CFR21 Part 11/GAMP 5<br>|||
|**Housing / Mechanics**<br>~~es~~<br>~~EOPT~~||~~PT~~||
|Enclosure material<br>~~es~~<br>~~PT~~<br>~~eS~~|PC. ABS<br>~~PT~~<br>~~eS~~|||
|Dimensions<br>~~es~~<br>~~PO~~|105 x 113 x 38 mm<br>~~PO~~|||
|IPprotection class<br>~~es~~<br>~~a~~|IP65|||
|Fireprotection class<br>~~a~~|UL94-V2|||
|Weight|240g|||
~~3]>~~ [ 105 mm J ~~as~~
38 mm
## **Compatible**
## **Delivery package**
HCD/PCD/CCD RMS-WEB RMS-CLD
- HygroClip DIGITAL
- RMS On-premises software
- RMS SaaS solutions
- Autonomous operation and audible alarms from V2.1
- Data logger, with clamps
- Short instruction manual
- 2 batteries
- Certificate
- Velcro strips
111
2022-V2
RMS Hardware
## RMS-LOG-T30-L/868/915
The RMS-LOG-T30 is a data logger with two integrated analog-to-digital converters, to which two PT100 sensors can be connected for high-precision temperature measurement. The measuring accuracy of the data logger with PT100 can be improved by a 1- or 2-point adjustment. The data logger stores 44,000 pairs of measured values and sends them to the RMS database via LAN or wireless interface.
## **FEATURES**
- Saving of up to 44,000 data points
- 2 x PT100 sensor connections
- 2-, 3- or 4-wire connection
- ±0.1 °C accuracy in measurement range
**General specifications** Measured parameters 2-, 3- and 4-wire RTD measurement ~~a a~~ Number of measuring points 2 x PT100 probes Accuracy[1] (@23 °C, without ±0.1 °C (-100 °C to 200 °C) PT100) ±0.2 °C (-200 °C to 850 °C) Application range -40...70 °C 0...100 %rh ~~a~~ Storage conditions -20...30 °C 0...95 %rh ~~a~~ Power 24 VDC ±10 % / <100 mA / PoE: 802.3 af-2003, Class 1 ~~a~~ AC adapter requirements 24 VDC ±10 % / >4 W / power-limited **Device data** ~~PT —~~ —————— ~~_ a~~ Measurement interval 10 s to 15 min. ~~a~~ Order code RMS-LOG-T30-xxx T30-L T30-868 T30-915 ~~a~~ Battery life (23 °C, 60 s interval) 3 years 2.4 years 2.4 years ~~a~~ Interfaces Ethernet ISM 868 MHz ISM 915 MHz Indoor wireless range - 20...50 meters 15...25 meters Compatibility with - V2.1 V2.1 RMS-GW-xxx Firmware Compatibility with Software ≥ V1.3.0 ~~spee~~ Protocols HTTP / MODBUS TCP ~~ee~~ (T30-L) ~~|]{{~~ Ethernet cable requirement Min. Cat 5, SFTP, max. 30 m 105 mm **Conformity with standards** ~~eee +~~ FDA / GAMP directives FDA CFR21 Part 11 / GAMP 5 ~~Cd~~ **Housing / Mechanics** Housing material PC, ABS ~~a~~ Fire protection class UL94-V2 Dimensions 105 x 113 x 38 mm IP protection class IP65 ~~a~~ Weight 240 g ~~a~~ ;
~~|]{{~~ 105 mm ~~+ L~~ ; 38 mm
In order to improve the measurement accuracy when using the data logger and the PT100, it is possible to carry out a
- 1 In order to improve the measurement accuracy when using the data logger and the PT100, it is possible to carry out a 1-point or 2-point adjustment. To calculate the total accuracy of the RMS-LOG-T30, all variables must be added.
## **Compatible**
## **Delivery package**
- RMS Gateway
- RMS On-premises software
- RMS SaaS solutions
- PT100 probe
RMS-GW RMS-WEB RMS-CLD T30-000X
- Data logger
- 2 batteries
- Wall bracket
- Short instruction manual
- 2 cable glands M12 x 1.5
112
2022-V2
RMS Hardware
## RMS Mini Logger
The wireless mini data logger is the low-cost data logger in the Rotronic Monitoring System. Its small housing and wireless interface make it a really flexible data logger. The mini logger is available in various sensor variants: internal temperature sensor (NTC), external temperature sensor (NTC), light, voltage measurement, current measurement or digital switch contact. With this versatility, it can monitor refrigerators and incubators, as well as door contacts and OEM analog devices.
## **FEATURES**
- Stores 10,000 measured values
- Fail-safe, thanks to internal battery
- Battery life up to 2.5 years
83 mm
87 mm
|• Battery life up to 2.5 years|• Battery life up to 2.5 years|• Battery life up to 2.5 years|||87 mm|87 mm|
|---|---|---|---|---|---|---|
|• Depending on the version, it measures temperature, current, voltage|||||||
||or light, or monitors a digital switch input||||||
|• ISM band 868 MHz / 915 MHz<br>**General specifications**<br>Device type<br>MS-MLOG-XXX-XXX<br>RMS-MDI-XXX<br>RMS-MADC-XXX-X<br>RMS-MLOG-BT-XXX<br>RMS-MLOG-B-XXX<br>Memorysize<br>10,000 measured values<br>13,000 datapoints<br>Range of application(electronics)<br>-30...85 °C/0...100 %rh<br>-40…85 °C/0…100 %rh<br>Battery life @23°C,<br>1 minute interval<br>2.2 years<br>2.5 years<br>IPprotection class<br>IP65<br>IP30(B),IP65(BT)<br>Workingrangepressure<br>300…1100 hPa<br>Storage conditions<br>-30...30 °C/0...95 %rh<br>Battery<br>1x RMS-BAT<br>Measurement interval<br>10 s to 15 min(software dependant)<br>**Wireless specifications**<br>Wireless interface<br>ISM 868 MHz<br>ISM 915 MHz<br>Indoor wireless range<br>20...50 meters<br>15...25 meters<br>**Conformity with standards**<br>FDA/GAMP directives<br>FDA 21 CFR Part 11/GAMP5<br>**Housing / Mechanics**<br>Housingmaterial<br>ABS<br>Dimensions<br>83 x 29 x 29 mm<br>Fireprotection class<br>UL94-V2<br>~~=_ ~~|||29 mm<br>32 mm<br> .||||
|**Measured parameters**|||||||
|RMS-MLOG-B-XXX||Temperature & humidity|||||
|RMS-MLOG-BT-XXX||Temperature & barometric pressure|||||
|RMS-MLOG-T--XXX||Temperature|||||
|RMS-MLOG-T10-XXX||Temperature with external probe (NTC)|||||
|RMS-MADC-XXX-V (0...10 V)||Power|||||
|RMS-MADC-XXX-A (0...20 mA)||Power input|||||
|RMS-MDI-XXX||Digital input|||||
|RMS-MLOG-LGT-XXX||Illumination|||||
## **Compatible**
## **Delivery package**
- Temperature probe
- RMS Gateway
- RMS On-premise
- RMS SaaS solutions
T10-xxxxx RMS-GW-868 RMS-WEB RMS-CLD
- Data logger
- Battery
- Wall bracket
- Short instruction manual
- 2 screws & 2 plugs
113
2022-V2
RMS Hardware
## RMS Gateway
The gateway is the interface between the wireless data logger and the server software. It can manage up to 60 data loggers simultaneously, collecting all wireless-logger measurement data, and passing them on to the server software. When several gateways are used in the same network, they are configured redundantly. If one gateway should fail, the measurement values are automatically sent to the server software via another gateway.
## **FEATURES**
- Connects 60 wireless data loggers simultaneously
- 5 wireless channels for parallel and redundant operation
## **General specifications**
|**General specificationspecificationsecifications**|**General specificationspecificationsecifications**|**General specificationspecificationsecifications**|
|---|---|---|
|Range of application|-40..70 °C,0..100 %rh||
|Storage conditions|-40..30 °C,0..95 %rh||
|Maximum altitude|2000 m ASL||
|Power supply|24 VDC ±10 %/<100 mA/PoE: 802.3 af-2003,Class 1||
|AC adapter requirements|24 VDC ±10 %/4 W nominal/<15 Wpower-limited||
|**Device data**|||
|Measurement interval|10 s to 15 min.||
|Startuptime|< 10 s||
|Order code|RMS-GW-868|RMS-GW-915|
|Interfaces|Ethernet & ISM868 MHz|Ethernet & ISM 915 MHz|
|Indoor wireless range|20..50 meters|15..25 meters|
|Protocols|HTTP||
|Ethernet cable requirement|Min. Cat. 5,SFTP,max. 30 m||
|**Conformity with standards**|||
|FDA/GAMP directives|FDA CFR21 Part 11/GAMP 5||
|**Housing / Mechanics**|||
|Housingmaterial|ABS||
|Fireprotection class|UL94 –V2||
|Dimensions|105 x 113 x 38 mm||
|IPprotection class|IP65||
|Weight|200g||
**==> picture [22 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
38 mm<br>**----- End of picture text -----**<br>
## **Compatible**
## **Delivery package**
- RMS Data Logger
- RMS Mini Logger
- RMS Display
- RMS On-premises software
- RMS SaaS solutions
RMS-LOG RMS-MLOG RMS-D RMS-WEB RMS-CLD
- Gateway
- Wall bracket
- Short instruction manual
- 2 screws & 2 plugs
114
2022-V2
RMS Hardware
## RMS Display
The LAN display is a freely configurable display. As a remote display, it can be placed optimally where it suits the viewer best. It is able to show the measured values, states and alarms of RMS products. The display shows up to four measured values. Two measured values are shown at a time. If more than 2 measured values have been selected, the display alternates between the values that are to be displayed every 5 seconds.
## **FEATURES**
• Shows up to 4 measured values • Automatic adjustment of backlight on alarm rere **General specifications** Device type RMS Display Display of measuring points Up to 4 measuring points Range of application -20...70 °C / 0...100 %rh Storage conditions -20...30 °C / 0...95 %rh Power supply 24 VDC ±10 % / <100 mA / PoE: 802.3 af-2003, Class 1 AC adapter requirements 24 VDC ±10 % / >4 W / power-limited Measurement interval 10 s Interface Ethernet Protocols HTTP **Conformity with standards** FDA / GAMP directives FDA CFR21 Part 11 / GAMP 5 **Housing / Mechanical parts** 105 mm Housing material PC, ABS Fire protection class UL94-V2 Dimensions 105 x 113 x 38 mm Display diagonal 2.26 inch IP protection class IP65 Weight 206 g ~~—— _|~~ 38 mm **Compatible Delivery package** • All measuring points • Display
- Display
- Wall bracket
- RMS Gateway
RMS-GW-868 RMS-WEB RMS-CLD
- Short instruction manual
- RMS On-premise
- RMS SaaS solutions
- 2 screws & 2 plugs
115
2022-V2
RMS Hardware
## RMS-ADC-L-R
The RMS-ADC-L-R is a data logger with two integrated analog-to-digital converters to which two sensors can be connected for high-precision analog measurement. The data logger stores 44,000 pairs of measured values and sends them to the RMS database via LAN.
## **FEATURES**
- 44,000 data point memory
• 2 analog sensor inputs
|**General specifications**<br>~~CCd~~|**General specifications**<br>~~CCd~~|
|---|---|
|Measurement interval<br>~~CCd~~<br>~~a~~|10 s to 15 min<br>~~d~~<br>~~a~~|
|Startuptime<br>~~a~~<br>~~a~~|< 10 s<br>~~a~~<br>~~a~~|
|Software compatibility<br>~~a~~<br>~~a~~|≥ V1.3.0<br>~~a~~<br>~~a~~|
|Protocols<br>~~a~~<br>~~a~~|HTTP/MODBUS TCP<br>~~a~~<br>~~a~~|
|Ethernet cable requirement<br>Alication ran<br>~~a~~<br>~~a~~|Min. Cat 5,SFTP,max. 30 m<br>-40…70 °Cnon-condensin<br>~~a~~<br>~~a~~|
|Application range<br>~~a~~|-40…70 °C,non-condensing<br>~~a~~|
|Storage conditions<br>Sensorl(Vex)<br>~~a~~<br>~~es~~|-20…30 °C,non-condensing<br>24 V/80 mA max.<br>~~a~~<br>~~es~~|
|Sensorpower supply (Vex)<br>~~es~~|24 V/80 mA max.<br>~~es~~|
|Current consumption<br>~~Rs~~|< 160 mA<br>~~Rs~~|
|AC adapter requirements<br>~~Rs~~<br>~~es~~|24 VDC ±10 %,4 W minimum,> 5 Wpower-limited<br>~~Rs~~<br>~~es~~|
|PoE<br>~~es~~<br>~~es~~|802.3af-2003,Class 1<br>~~es~~<br>~~es~~|
|**Conformity with standards**<br>~~es~~<br>~~CL~~||
|Solderingmaterial<br>~~CL~~|Lead free/RoHS conformity<br>~~CL~~|
|FDA/GAMP directives<br>FDA CFR21 Part 11/GAMP 5<br>**Device data**<br>~~es nn~~<br>~~CL~~||
|Accuracy<br>~~CL~~<br>~~a~~|± 0.03 % full-scale<br>~~CL~~<br>~~a~~|
|Temperature accuracy<br>~~a~~<br>~~ee~~|± 0.02 % full-scale/°C<br>~~a~~<br>~~ee~~|
|Measuring resistance / Load<br>~~ee~~|25 kΩ at voltage input<br>250 Ω at current input<br>~~ee~~|
|Number of measuring points<br>~~es~~|1 or 2 analoginputs<br>~~es~~|
|Measurement ranges<br>~~es~~<br>~~a~~|0...1 V,0...5 V,0...10 V,0...20 mA and 4...20 mA<br>~~es~~<br>~~a~~|
|Storage capacity<br>~~a~~<br>~~a~~|44,000 datapoints<br>~~a~~<br>~~a~~|
|Sensor quality<br>~~a~~|• Detection of sensor interruption (open loop)<br>• Detection of overload<br>• Detection of underload at 4...20 mA<br>~~a~~|
|**Housing / Mechanics**<br>~~CL~~||
|Housingmaterial<br>~~a~~|PC. ABS<br>~~a~~|
|Dimensions<br>~~a~~|110 x 119 x 22.5 mm<br>~~a~~|
|IPprotection class<br>~~a~~|IP20<br>~~a~~|
|Fireprotection class<br>~~es~~|UL94-V0<br>~~es~~|
|Weight<br>~~es~~|125g<br>~~es~~|
## **Compatible**
## **Delivery package**
- RMS On-premises software ≥ V1.3.0
- Data logger, with clamps
RMS-WEB RMS-CLD
- Short instruction manual
- RMS SaaS solutions ≥ V1.3.0
**==> picture [121 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
22.5 mm<br>—<br>101 mm<br>119 mm<br>**----- End of picture text -----**<br>
- Certificate
116
2022-V2
RMS Hardware ~~PSTrotronic~~
## RMS-DI-L-R
The digital input module stores all measured data on an event basis and sends it to the database via Ethernet. The minimum pulse time is 100 ms. Should the connection be lost, the module stores the data intermediately to protect data integrity and fills up the data gaps when the connection has been restored. The device has a battery so that logging of measured data is also ensured in the event of a failure in the external power supply.
## **FEATURES**
- Two input channels
- Data logging of up to 75,000 measured values
|**General specifications**<br>~~TT~~<br>~~PF~~<br>~~O™O™—OOOCOCOC“C“‘“‘(SN~~|**General specifications**<br>~~TT~~<br>~~PF~~<br>~~O™O™—OOOCOCOC“C“‘“‘(SN~~|
|---|---|
|Device type<br>~~PF~~<br>~~O™O™—OOOCOCOC“C“‘“‘(SN~~|RMS-DI-L-R<br>~~O™O™—OOOCOCOC“C“‘“‘(SN~~|
|Number of inputs<br>~~PF~~<br>~~O™O™—OOOCOCOC“C“‘“‘(SN~~<br>~~Oa~~<br>~~Ge~~|2 independent digital inputs<br>~~O™O™—OOOCOCOC“C“‘“‘(SN~~<br>~~Oa~~<br>~~Ge~~|
|Range of application<br>~~Oa~~<br>~~Ge~~|-40..70 °C/0..100 %rh non-condensing<br>~~Oa~~<br>~~Ge~~|
|Storage conditions<br>~~Ge~~<br>~~i~~|-40..30 °C/0..95 %rh<br>~~Ge~~|
|Maximum altitude<br>~~Ge~~<br>~~a~~<br>~~i~~|2000 m ASL<br>~~Ge~~<br>~~a~~|
|Power supply<br>~~a~~<br>~~SO~~<br>~~i~~|24 VDC ±10 %/<100 mA/PoE: 802.3 af-2003,Class 1<br>~~a~~<br>~~SO~~|
|AC adapter requirements<br>~~SO~~<br>~~i~~|24 VDC ±10 %/4 W nominal/<15 Wpower-limited<br>~~SO~~|
|Batterytype<br>~~i~~<br>~~a~~|RMS-BAT|
|Batterylife<br>~~i~~<br>~~a~~|3years at 23 °C|
|**Device data**||
|Input frequency<br>~~a~~|Max. 0.833 Hz or 1.2 s|
|Pulse recognition<br>~~a~~<br>~~a~~|>100 ms(periodically> 1.2 s)|
|Input circuit<br>~~a~~<br>~~BE~~|Logic level: 0 V/5-24 V<br>~~Po~~<br>~~BE~~|
||Trigger threshold: ~3.77 V<br>~~Po~~<br>~~BE~~<br>~~PI~~|
||Current consumption: <1 mA<br>~~BE~~<br>~~PI~~|
|Reed circuit<br>~~BE~~|Max. load at input 100 kΩ<br>~~BE~~<br>~~PI~~|
|Max. cable length at input<br>~~a~~|<3 m|
|Measurement interval<br>~~a~~|Event-based & interval(10 s to 15 min.)|
|Storage capacity|75,000 datapoints|
|Interface|Ethernet|
|Protocols<br>~~Po~~|HTTP|
|**Conformity with standards**<br>~~Po~~||
|FDA/GAMP directives<br>~~Po~~<br>~~a~~|FDA CFR21 Part 11/GAMP 5|
|**Housing / Mechanicalparts**<br>~~a~~<br>~~fF~~||
|Housingmaterial<br>~~fF~~<br>~~C™~—OCOCSCSCSSC“‘SsSC“‘“S™SCS*S~~|Polycarbonate(PC)<br>~~C™~—OCOCSCSCSSC“‘SsSC“‘“S™SCS*S~~|
|Fireprotection class<br>~~fF~~<br>~~C™~—OCOCSCSCSSC“‘SsSC“‘“S™SCS*S~~<br>~~a~~|UL94-V0<br>~~C™~—OCOCSCSCSSC“‘SsSC“‘“S™SCS*S~~<br>~~a~~|
|Dimensions<br>~~a~~|89.7 x 62.2 x 108 mm<br>~~a~~|
|IPprotection class<br>~~a~~|IP20<br>~~a~~|
|Weight<br>~~a~~<br>~~[I~~|206g<br>~~a~~<br>~~[I~~|
## **Compatible**
## **Delivery package**
- RMS-Config
- RMS On-premise
- RMS SaaS solutions
RMS-WEB RMS-CLD
- Digital module
- 2 batteries
- Wall bracket (wall-mounted housing)
- Short instruction manual
- 2 screws & 2 plugs
117
2022-V2
RMS Hardware
## RMS-DO-L-R
The digital output module serves to display information, issue alarms and control events. The relays can be interrogated or set via Modbus TCP or the RMS software. It is possible to define the conditions in the RMS software and to actuate the outputs on the basis of them.
## **FEATURES**
- Two output channels
|**General specifications**|**General specifications**|
|---|---|
|Device type|RMS-DO-L-R|
|Number of outputs|2, polarity-independent|
|Range of application|-40..70 °C/0..100 %rh non-condensing|
|Storage conditions|-40..30 °C/0..95 %rh|
|Maximum altitude|2000 m ASL|
|Power supply|24 VDC ±10 %/<100 mA/PoE: 802.3 af-2003,Class 1|
|AC adapter requirements|24 VDC ±10 %/4 W nominal/<15 Wpower-limited|
|**Device data**||
|Interface|Digital signal/ galvanicallyisolated|
|Relayswitchingcapacity|50 VAC(peak)1 A/50 VDC/1 A, polarity-independent|
|Voltage output (VEX)|24 VDC (Note: The maximum current available depends<br>on the externalpower supplyconnected)|
|Max. cable length at input|<3 m|
|Measurement interval|>=10 s|
|Interface|Ethernet|
|Protocols|HTTP|
|**Conformity with standards**||
|FDA/GAMP directives|FDA CFR21 Part 11/GAMP 5|
|**Housing / Mechanicalparts**||
|Housingmaterial|Polycarbonate(PC)|
|Fireprotection class|UL94-V0|
|Dimensions|89.7 x 62.2 x 108 mm|
|IPprotection class|IP20|
|Weight|155g|
## **Compatible**
## **Delivery package**
- RMS-Config
- RMS On-premise
- RMS SaaS solutions
RMS-WEB RMS-CLD
- Digital module
- Wall bracket (wall-mounted housing)
- Short instruction manual
- 2 screws & 2 plugs
118
2022-V2
RMS Hardware
## RMS Converter
The RMS Converter allows you to easily integrate existing devices and networks into RMS. The RMS Converter acts as an interface, gathering the data from digital devices and sending them to the RMS server software/MS SQL database. In addition, third party digital devices can be integrated if the communication protocol is MODBUS TCP. However, this function requires support from the Rotronic R&D. Where ever possible Rotronic would recommend replacing previous networks with RMS devices in the long term.
## **FEATURES**
- Integrates digital devices seamlessly into RMS
- Integrates Rotronic digital devices into RMS
- No loss of accuracy due to A/D converters, show up to 5 decimal values
## **General specifications**
|**General specificationspecificationsecifications**|**General specificationspecificationsecifications**|
|---|---|
|Device type|RMS Converter|
|Number of measuring points|Integration of upto 100|
|Range of application|-0 .. 50 °C/0 .. 95 %rh|
|Storage conditions|-0 .. 50 °C/0 .. 95 %rh|
|Electrical Supply|5 VDC(universal mains adapter included)|
|Measurement interval|10 s to 15 min|
|Interface|Ethernet|
|Protocols|Modbus TCP<br>RoASCII<br>HTTP<br>SNMP<br>Customer-specific enhancements|
|Supported webcams|D-Link DCS-2121|
|**Conformity with Standards**||
|FDA/GAMP directives|FDA 21 CFR Part 11/GAMP 5|
|**Housing / Mechanicalparts**||
|Dimensions|94 x 78 x 30 mm|
|IPprotection class|IP20|
## **Compatible**
## **Delivery package**
• Transmitter HF4..HF8 (Ethernet) • Transmitter PF4/5 (Ethernet) • RMS On-Premise RMS-WEB • RMS SaaS solutions RMS-CLD • Clean room panel CRP5 • Analogue to digital converter RMS-8ADC-L-R-A/V • RTD to digital converter RMS-4RTD-L-R • Particle counter All with Modbus TCP interface
- Converter
- Short instruction manual
- AC adapter
- Ethernet cable
- USB cable
119
2022-V2
RMS Hardware
## AD-0001
The AD-0001 will warn users both visually and aurally of any alarms that are setup within the Rotronic monitoring system. Alarms can be setup via the alarm scheme as well as via the script function (IF/OR/AMD/THEN) and then triggered from the actions settings.
## **FEATURES**
- Direct visual or sound alarming
- Alarming via thresholds or scripts (IF/OR/AND/THEN)
- Permanent or blinking red LED
- Permanent or pulsing buzzer
|**General specifications**|**General specifications**|
|---|---|
|Device type|AD-0001|
|Range of application|-20...50 °C/0...95 %rh|
|Storage conditions|-0...50 °C/0...95 %rh|
|Electrical supply|24 VDC(power can be supplied via the RMS-DO-L-R)|
|Light|Red LED|
|Sound|< 85 dB|
|**Housing / Mechanicalparts**||
|Height|154.5 mm without mountingbracket|
|Diameter|70 mm|
|IPprotection class|IP65|
|Housingmaterial|PA and PC|
## **Sound pressure level dB (A)**
|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|**Distance in m**<br>**1**<br>**2**<br>**3**<br>**5**<br>**10**<br>**20**<br>**30**<br>**50**<br>**100**<br>**200**<br>**300**<br>**500**<br>**1000**<br>~~a~~|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|100<br>~~a~~|94<br>~~es~~|90|86|80|74|70|66|60|54|50|46|40|
|90<br>~~a~~|84<br>~~es~~<br>~~es~~|80|76<br>~~OO~~|70<br>~~OO~~|64<br>~~OO~~|60<br>~~OO~~|56|50|44|40|||
|85|79<br>~~es~~<br>~~es~~<br>~~es~~|75|71<br>~~OO~~<br>~~OO~~|65<br>~~OO~~<br>~~OO~~|59<br>~~OO~~<br>~~OO~~|55<br>~~OO~~<br>~~OO~~|51|45|39||||
|70|64<br>~~es~~<br>~~es~~|60|56<br>~~OO~~<br>~~OO~~|50<br>~~OO~~<br>~~OO~~|44<br>~~OO~~<br>~~OO~~|40<br>~~OO~~<br>~~OO~~|36||||||
## **Compatible**
## **Delivery package**
- RMS-DO-L-R
- Device
120
2022-V2
RMS Hardware
## RMS-TD-0001
Strict guidelines require high temperature stability in many areas and only allow the smallest fluctuations. However, there are unavoidable fluctuations fridge temperature when the door opens, which must be buffered to ensure that the probe temperature measurement is representative of the product temperature. As of such, the monitored temperature is more stable and meaningful. The sensor holder is traceable end-to-end and meets all FDA and GxP environments.
## **FEATURES**
**==> picture [44 x 75] intentionally omitted <==**
**----- Start of picture text -----**<br>
PET bottle<br>Mounting<br>bracket<br>**----- End of picture text -----**<br>
- Ensure that the temperature measurement is representative of the product temperature with this temperature buffer
- Easy installation of temperature probes in fridges and freezers
**General specifications** Order code RMS-TD-0001 Temperature range -196…40 °C PET bottle Polyethylene terephthalate (PET) Mounting bracket Polylactide (PLA) Sand Biloxit (certified) ~~——~~ Dimensions 34 x 110 mm
- **Delivery package** • PET bottle • Lid with seal • Sand (weighed for the bottle) • Two centering sleeves (suitable for 6 mm diameter probes only) • Mounting bracket • Cable ties
- ~~a~~
121
2022-V2
RMS Hardware
## WB-0001
The WB-0001 detects the presence of water or conductive fluids once it reaches a level that bridges the two conductive strips on the bottom of the housing. Once the strips are bridged, audible and visual alerts as well as an internal switch are triggered. The sensing hight can be adjusted from 0.08 mm to 13.5 mm using the included adjustable mounting bracket (that can be attached to any flat surface by either using the attached adhesive strips or mounting screws).
## **FEATURES**
- Detect leaks as soon as they occur
- Visual and audible alarm
- Battery powered
- Adjustable sensing hight
- Relay output
## **General specifications**
|**General specificationspecificationsecifications**|**General specificationspecificationsecifications**|
|---|---|
|Parameters|Water or conductive fluids|
|Range of application|0…50 °C|
|Power supply|3V CR2450 lithium metal battery|
|Batterylifetime|5years steadystate/48 hours duringalarm condition|
|y<br>Power consumption|yyg<br>0.9 mA steadystate/3.0 mA duringalarm condition|
|Dimensions|53 x 105.23 x 30.77 mm|
|Housing|ABS andpolycarbonate|
|Cable length<br>IPprotection class|1.5 m<br>Water tight upto 3/4 of the bodyhight|
|IPprotection class<br>Weight|Water tight upto 3/4 of the bodyhight<br>137.5g|
|**Technical Information/ Functions**||
|**/**<br>Switch type|SPST NO SSR|
|Audible alarm|At least 85dB@30 cm distance|
|Visual alarm|Red LED for water level,Yellow LED for low battery|
## **Compatible**
## **Delivery package**
- RMS-MDI-868/915
- 1 CR2450 lithium metal battery
- Short instruction manual
- RMS-DI-L-R
**==> picture [73 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
53 mm<br>i<br>imi<br>105.23 mm<br>30.77 mm<br>**----- End of picture text -----**<br>
122
2022-V2
RMS Accessories
## Temperature probes
The RMS temperature portfolio will cover a various array of applications, from the coldest such as liquid nitrogen tanks and cryogenic freezers to freezers, refrigerators and cold rooms to hotter ones such as water baths, incubators, ovens and autoclaves. Certain probes are also designed for specific applications for monitoring legionella within water pipes and monitoring room temperature.
## **T10-0001**
- Applications: liquid nitrogen, cyrogenics…
- Application range: -196…-90 °C
- Cable length: 2 m
- Probe diameter: 6-6.15 mm
- Probe length: 50 mm
- IP65
- Select NTC T10-0001 within RMS
- Sensor: NTC
## **T10-0002**
- Applications: Dry ice, freezers…
- Application range: -80…150 °C
- Cable length: 2 m
- Probe diameter: 6-6.15 mm
- Probe length: 50 mm
- IP65
- Select NTC T10-0002/0006 within RMS
- Sensor: NTC
## **T10-0003/T10-0013/T10-0113**
- Applications: freezers, fridges, cold rooms, water baths, incubators, ovens…
- Application range: -50…120 °C
- Cable length: 2 m
- Probe diameter: 6-6.15 mm
- Probe length: 50 mm
- IP65
- Select NTC T10-0003/4 within RMS
- Sensor: NTC
123
2022-V2
RMS Accessories ~~see~~
## Temperature probes
**T10-0005**
- Applications: Dry ice, freezers… • Application range: -90…0 °C ~~a~~
- Cable length: 4 m
- Probe diameter: 6-6.15 mm
- Probe length: 50 mm
- IP68
- Select NTC T10-0005 within RMS
- Sensor: NTC
## **T10-0006**
- Applications: freezers, fridges, cold rooms, water baths, incubators, ovens…
- Application range: -80…150 °C
- Cable length: 4 m
- Probe diameter: 6-6.15 mm
- Probe length: 50 mm
- IP65
- Select NTC T10-0002/0006 within RMS
- Sensor: NTC
- ~~—————~~ **T30-0001** & • Applications: Cryotechnology, dry ice • Application range: -196…260 °C
- Cable length: 2000 mm
- Probe diameter: 6-6.15 mm
- Probe length: 50 mm
- IP68
- Sensor: 4 wire Pt100
## **T30-0003**
- Applications: Standard
- Application range: -50…200 °C
- Cable length: 2000 mm
- Probe diameter: 6 mm
- Probe length: 50 mm
- IP65
- Sensor: 4 wire Pt100
## **T30-0006**
- Applications: Standard
- Application range: -50…200 °C
- Cable length: 4000 mm
- Probe diameter: 6 mm
- Probe length: 50 mm
- IP65
- Sensor: 4 wire Pt100
124
2022-V2
RMS Accessories
## Temperature probes
## **T30-0010**
- Application range: -190...200 °C
- Cable length: 4000 mm
- Probe diameter: 3.6 mm
- Probe length: 50 mm
- IP65
- Sensor: 4 wire Pt100
## **T30-0012**
- Application range: -190...260 °C
- Cable length: 2000 mm
- Probe diameter: 3 mm
- Probe length: 50 mm
- IP68
- Sensor: 4 wire Pt100
## **T30-0013**
- Applications: Doors
- Application range: -50…200 °C
- Cable length: 2000 mm
- Probe diameter: 6 mm
- Probe length: 50 mm
- IP65
- Sensor: 4 wire Pt100
125
2022-V2
**Humidity and Temperature Temperature Differential pressure CO2 Applications Rotronic Monitoring System – RMS Software** ee **EcoLine – Humidity & Temperature Services Theory**
126
2022-V2
Software HW5
## Software editions
## **HW5 STANDARD (FOR FREE)**
- Single-user applications license
- Visualization of multiple loggers and measured values
## **HW5 WITH WATER ACTIVITY MEASUREMENT**
- All functions of the HW5 standard
- AW Quick function for fast determination of water activity
## Function overview
|**Function overview**|**Function overview**|**Function overview**|
|---|---|---|
|The HW5 software from Rotronic constitutes a professional monitoring and<br>configuration tool and is licensed. Multiple use of one license is permitted<br>as longas the installed software is used at the same site address.|Standard<br>HW5-P-V3-Code|Professional with<br>water activity<br>HW5-AW-Code|
|**Viewing of measured values/Monitoring**|||
|Displayof measured values on a monitor for multiple instruments|v|Vv|
|**Display of measured values**|||
|Numeric andgraphic display|~~Vv~~|~~Vv~~|
|Graphic comparisons and overlayfunctions|~~Vv~~<br>~~Vv~~|~~Vv~~<br>~~Vv~~|
|**Analysis and calculation tool**<br>~~Vv~~<br>~~Vv~~|||
|Psychrometricparameters|~~Vv~~|~~Vv~~|
|Statistics|~~Vv~~<br>~~Vv~~|~~Vv~~<br>~~Vv~~|
|**Printing/Reports**<br>~~Vv~~<br>~~Vv~~|||
|Automaticgeneration of adjustment, calibration and configuration reports|~~Vv~~|~~Vv~~|
|Printout as table,graph or PDF report|~~Vv~~<br>~~Vv~~|~~Vv~~<br>~~Vv~~|
|**Users andpasswords**<br>~~Vv~~<br>~~Vv~~|||
|Passwordprotection|~~Vv~~|~~Vv~~|
|Users freelyselectable. Rights freelydefinable|~~Vv~~<br>v|~~Vv~~<br>Vv|
|**Water activity measurement**|||
|AwQuick and AwE||Vv|
|**Supported interfaces**|||
|NFC and USB|v|Vv|
|RS-485<br>**ecific functions**|~~Vv~~|~~Vv~~|
|**Instrument-specific functions**<br>~~Vv~~<br>~~Vv~~|||
|Instrument settings, scaling, programming, data retrieval,<br>data loggingfunctions|Vv|Vv|
|Adjustment and calibration of Rotronicprobes|~~Vv~~|~~Vv~~|
|Simultaneous adjustment ofprobes in onegroup|~~Vv~~<br>~~Vv~~|~~Vv~~<br>~~Vv~~|
|Time synchronization for data loggers|~~Vv~~<br>~~Vv~~|~~Vv~~<br>~~Vv~~|
## Description of functions
## **VIEWING OF MEASURED VALUES**
Viewing of measured values is very easy and user-friendly. Files of any device shown in the device tree can be copied and opened directly with the HW5 Explorer. The data is presented in both tabular and graphical formats.
The graph module can be configured by the user.
127
2022-V2
Software HW5
## **Instrument configuration**
The HW5 software can be used to adjust the settings of Rotronic instruments and probes. Depending on the instrument and probe, the following functions and settings can be changed:
- Assignment and scaling of transmitter outputs
- Definition of alarm values
- Relay switch points
- Adjustment and calibration of probes
## **Analysis and calculation tool Psychrometric parameters**
All Rotronic instruments measure relative humidity in %rh and temperature in °C/°F. These two values can be used to calculate other psychrometric values such as dew point, mixing ratio, enthalpy and wet bulb temperature. The calculation module in HW5 software uses WMO*-verified formulas for these calculations and allows users to define their own parameters (e.g. mixing ratio & temperature) as input values in order to calculate the relative humidity from them. Other advanced options such as dew/frost point differentiation are also included.
## **Statistical functions / PDF report**
For many users detailed data, which can be very extensive, is not necessarily of much interest. For them it is merely important that the measured values lie within a certain range. The statistical function and integrated PDF report enable simple and detailed data evaluation for this.
It shows the following values:
- Min., max. and mean value (during a defined period or during the time of an alarm)
- Standard deviation
- Mean kinetic temperature
- Number of measured values
- Total time measurements exceeded a certain value
## **Users and passwords**
## ~~a~~
User names and passwords can be defined and assigned freely. Every user can be granted different rights. Users can be blocked and reactivated again. Users that have been deleted cannot be recreated under the same name.
## **CP11 / CL11**
Instrument configuration and downloading of data.
## **HF1**
Instrument configuration and adjustment of humidity and CO2.
- WMO = World Meteorological Organisation
128
2022-V2
|**Humidity and Temperature**|||
|---|---|---|
|**Temperature**|||
|**Differential pressure**<br>©|©|©|
|**CO2**|||
|**Applications**|||
|**Rotronic Monitoring System – RMS**<br>(es)|(es)|(es)|
|**Software**<br>a|a|a|
|**EcoLine – Humidity & Temperature**<br>eG)|||
|**Services**|||
|**Theory**|||
129
2022-V2
EcoLine Humidity and Temperature probes ~~Troon~~
## PC-Series
## **ADVANTAGES**
- High accurate measurements in precision manufacturing applications
- Built in interchangeable Hygrosmart module
- Different probe types; analog or digital
- Available in different materials Polymer or stainless steel
## **APPLICATIONS**
- Production environment
- Industrial Manufacturing
- Meteorological applications
- Climate chambers
**==> picture [240 x 67] intentionally omitted <==**
**----- Start of picture text -----**<br>
PCMini52<br>PC62 & PC62V<br>PC33 & PC52<br>**----- End of picture text -----**<br>
## PC62 & PC62V
- Application range: 0…100 %rh, -20…80 °C
- Accuracy: <±2 %rh (10...90 %rh), ±0.2 K @ 23°C
- Stability: ±1 %rh/year
- Materials: Molded polymer or stainless steel
**==> picture [96 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin 1 (ey, Pin 4<br>Pin 2 Pin 3<br>**----- End of picture text -----**<br>
## **Electrical Connections**
|**Voltage output**||||||||
|---|---|---|---|---|---|---|---|
|**Cable**|**Connector**|||**Cable**|**Connector**|**RS232**|**RS485**|
|White|Pin 1|Power supplyV +||White|Pin 1|Power supplyV +|Power supplyV +|
|Green|Pin 4|Output rh +||Green|Pin 4|TX|TX/RX +|
|Yellow|Pin 2|Output temperature +||Yellow|Pin 2|RX|RX/TX -|
|Brown|Pin 3|Commonground||Brown|Pin 3|Ground|Ground|
## PCMini52
80mm 91mm (3.15”) (3.58”) 12.5mm 12.5mm • Application range: 0…100 %rh, -20…80 °C 11mm (0.49”) 11mm (0.49”) • Accuracy: <±2 %rh (10...90 %rh), ±0.2 K @ 23 °C (0.43”) (0.43”) • Stability: ±1 %rh/year • Output: Modbus RTU / Voltage ~~a~~ = — ~~_~~ • Materials: Molded polymer or stainless steel Ø12mm (0.47”) M12 x 1 Ø12mm (0.47”) M12 x 1 **Electrical Connections Mating Cable Pin** M12 x 1 **Voltage output Cable Connector** 2 4 M8 x 1 Brown Supply voltage V + 1 1 © © 3 Brown Pin 1 Power supply V + White Modbus 2 White Pin 2 Output rh + Blue V - 3 Blue Pin 3 Output temperature + Black Modbus 4 Black Pin 4 Common ground ~~=—= ———_——~~
130
2022-V2
EcoLine Humidity and Temperature probes
## PC33 & PC52
**==> picture [353 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
• Application range: 0…100 %rh, -20…80 °C<br>• Accuracy PC52: ±2 %rh (10...90 %rh), ±0.2 K @ 23 °C Pin 1 Pin 4<br>• Accuracy PC33: ±3 %rh (30...80 %rh), ±0.3 K @ 23 °C<br>• Stability: ±1 %rh/year<br>• Materials: Molded polymer or stainless steel Pin 2 Pin 3<br>�<br>� �<br>�<br>**----- End of picture text -----**<br>
## **Electrical Connections**
|**Voltage output**|**Voltage output**|**Voltage output**||**4-20 mA Output 2-wire**|**4-20 mA Output 2-wire**|**4-20 mA Output 2-wire**|
|---|---|---|---|---|---|---|
|**Mating Cable**||**Pin**||**Mating Cable**||**Pin**|
|White|Supplyvoltage V +|1||White|Output rh +|1|
|Yellow|Output temperature +|2||Yellow|Output temperature -|2|
|Brown|Commonground|3||Brown|Output rh -|3|
|Green|Output rh +|4||Green|Output temperature +|4|
## **Technical Information**
**==> picture [511 x 213] intentionally omitted <==**
**----- Start of picture text -----**<br>
PC33 & PC52 PC62 & PC62V PCMini52<br>Probe type Analog relative humidity and Digital relative humidity and Digital relative humidity and<br>temperature temperature temperature<br>Measuring range -20…80 °C / 0…100 %rh<br>Accuracy at 23 °C PC33: ±3 %rh (30…80 %rh) / ±0.3 K<br>±2 %rh (10…90 %rh) / ±0.2 K ±2 %rh (10…90 %rh) / ±0.2 K<br>PC52: ±2 %rh (10…90 %rh) / ±0.2 K<br>Long-term stability <1 %rh / year<br>Probe housing Molded polymer or stainless<br>Molded polymer or stainless steel<br>steel<br>IP Protection rating IP65<br>Power supply 14…35 VDC (0…5 V/0…10 V<br>14…30 VDC (0…5 V/ 0…10 V output) 14…30 VDC (0…5 V/ 0…10 V<br>output)<br>5…30 VDC (0…1 V & mA output) output) 5…30 VDC (0…1 V)<br>6…35 VDC (0…1 V output)<br>Output signal Modbus RTU<br>4–20 mA, 0 to 1, 0 to 5, 0 to 10 V 0–1, 0–5, 0–10 V, RS232, RS485<br>0 to 1, 0 to 5, 0 to 10 V<br>Response time rh sensor <10 sec typical (for 90% of the step change)<br>Electrical connections 4 pin, M8 connector<br>M12<br>4 pin, M12 connector<br>Weight 30 g (1.06 oz) without cable (molded polymer version) 10 g (0.35 oz)<br>**----- End of picture text -----**<br>
131
2022-V2
EcoLine Humidity and Temperature probes
## **PC-SERIES ACCESSORIES AND SPARE PARTS**
**==> picture [512 x 540] intentionally omitted <==**
**----- Start of picture text -----**<br>
Order Code Compatibility Product / Description<br>Protection cap<br>A000002 PC62 & 62V, PC33 & PC52 19mm (0.75") Slotted protection cap black<br>A000003 PCMini52 12mm (0.47") Slotted protection cap black<br>A000046 PCMini52 13mm HDPE Protection cap<br>A000120 PC62 & 62V, PCMini52, PC33 & PC52 ø90mm (3.54") WM weather protection cap (for ø19mm (0.75") probes)<br>A000125 PC62 & 62V, PCMini52, PC33 & PC52 ø120mm (4.72") WM weather protection cap (for ø19mm (0.75") probes)<br>Filter<br>A000014 PC62 & 62V, PC33 & PC52 19mm (0.75") PVDF filter<br>A000015 PC62 & 62V, PC33 & PC52 19mm (0.75") PVDF filter w/ protection cap black<br>A000017 PCMini52 12mm (0.47") PVDF filter<br>A000018 PCMini52 12mm (0.47") PVDF filter w/ protection cap black<br>A000021 PC62 & 62V, PC33 & PC52 19mm (0.75") Mesh filter w/ protection cap black<br>A000022 PCMini52 12mm (0.47") Mesh filter w/ protection cap black<br>A000023 PCMini52 12mm (0.47") Flat SS sintered dust filter<br>A000025 PC62 & 62V, PC33 & PC52 19mm (0.75") Arrow 5μm SS sintered filter<br>A000027 PC62 & 62V, PC33 & PC52 19mm (0.75") connector, no cable, w/screw terminal<br>A000028 PCMini52 12mm (0.47") Arrow 20μm SS sintered filter<br>A000040 PC62 & 62V, PC33 & PC52 19mm (0.75") Foil filter 2μm w/protection cap black<br>A000042 PC62 & 62V, PC33 & PC52 19mm (0.75") Oleophobic foil filter 0.7μm (w/protection cap black)<br>12mm (0.47”) Mesh filter with protection cap, light brown,<br>K9 PCMini52<br>extra long (30mm)<br>K10 PCMini52 12mm (0.47”) PTFE filter with peek protection cap<br>K11 PCMini52 12mm (0.47”) Slotted protection cap, light brown, extra long (30mm)<br>Cable<br>19mm (0.75”) Connector<br>A000030-xx<br>- Connector<br>xx = total length i.e. PC62 & 62V, PC33 & PC52<br>- Cable (price per meter)<br>A000030-20<br>A000031 PC62 & 62V, PC33 & PC52 19mm (0.75") connector with 2m (6.5') cable<br>A000032 PC62 & 62V, PC33 & PC52 19mm (0.75") connector with 5m (16') cable<br>A000033 PCMini52 12mm (0.47") connector with 2m (6.5') cable<br>A000036 PCMini52 12mm (0.47") connector with 5m (16') cable<br>A000037 PCMini52 12mm (0.47") connector with 10m (32.8') cable<br>A000321 PCMini52 12mm (0.47") connector without cable (with solder terminal)<br>A000321-xx 12mm (0.47”) connector<br>xx = total length i.e. PCMini52 - Connector<br>A000321-20 - Cable (price per meter)<br>A000322 PCMini52 12mm (0.47") Connector with 20m (25.6') cable<br>Mounting<br>A000100 PC62 & 62V, PC33 & PC52 3/4" NPT SS adj. fitting for SS probes<br>A000101 PCMini52 1/2" NPT SS adj. fitting for SS probes<br>Al mounting flange for ø19mm (0.75") SS probes (outside ø80mm<br>A000110 PC62 & 62V, PC33 & PC52<br>(3.15"))<br>Al mounting flange for ø12mm (0.47") SS probes (outside ø40mm<br>A000111 PCMini52<br>(1.57"))<br>A000150 PC62 & 62V, PC33 & PC52 Mini flange for ø19mm (0.75") polymer probe<br>**----- End of picture text -----**<br>
132
2022-V2
EcoLine Humidity and Temperature probes
## **COMPATIBILITY**
- PC-Series are standalone probes which are not compatible with Rotronic transmitters and Rotronic handhelds.
- The only compatible accessories and spare parts like filters, protection caps, mounting clips etc. are listed here.
- In case of insecurity, please contact your local Rotronic partner.
**==> picture [304 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
HC2A-S | — HCA-SM j HC2A-S he Be<br>**----- End of picture text -----**<br>
## **MODBUS REGISTER (PCMINI52)**
|**Register**|**Content**|**Format**|
|---|---|---|
|0|T ambient|235 = 23.5 °C|
|1|rh|457 = 45.7 %|
|2|Model type|64480(fixed)|
|3|Trade mark|5000(fixed)|
|4|Software release|xx.xx|
|5/6|Futurepurposes(don’t use)|-|
|7|Modbus Device Address|Default 1|
|8|Baud rate|2 = 9600,3=19200|
|9...13|Factory purposes|-|
|14|Flashprotect|Default 0|
|15...254|Factory purposes(calibration registers)|-|
133
2022-V2
EcoLine Humidity and temperature transmitter
## DT722
## **BENEFITS**
- Relative humidity, temperature measurement and dew point
- Designed for accurate measurement in a harsh environment
- Stainless steel housing
- Long term stability: ±1 %rh over 12 months
- Withstands temperatures up to 150 °C (300 °F)
## **APPLICATIONS**
- HVAC
- Heating, ventilation, air conditioning
- Food industry
- Pharmaceutical industry
- Printing and paper industries
## **ELECTRICAL CONNECTIONS**
|**Connections**|**Connections**|**Connections**|
|---|---|---|
|**Cable**|**Pin**||
|White|Pin 1|Supply+ 8...32 VDC|
|Yellow|Pin 2|Output 2 = Temp4...20 mA(max. 500Ω)|
|Brown|Pin 3|Not connected(for calibration only)|
|Green|Pin 4|Output 1 = RH 4...20 mA(max. 500Ω)|
||Pin 5|Not connected(for calibration only)|
Note: Both RH and T need to be connected in order for the T output to work.
**==> picture [14 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 1<br>5<br>3 4<br>**----- End of picture text -----**<br>
Note: Even though the DT722 has a 5 pin connector, the standard connection cable (A000031) only has four pins/wires. However, only three pins (1, 2 and 4) are needed to connect the DT722.
## **ACCESSORIES AND SPARE PARTS**
|**Order Code**|**Description**|
|---|---|
|**Protection cap**||
|A000002|19 mm(0.75")Slottedprotection capblack|
|**Filter**||
|A000014|19 mm(0.75")PVDF filter|
|A000015|19 mm(0.75")PVDF filter w/ protection capblack|
|A000021|19 mm(0.75")Mesh filter w/ protection capblack|
|A000025|19 mm(0.75")Arrow 5μm SS sintered filter|
|A000027|19 mm(0.75")connector,no cable,w/screw terminal|
|**Cable**||
|A000030|Singleplug,without cable|
|A000030-XX|19 mm(0.75")connector/cable(priceper meter)|
|A000031|19 mm(0.75")connector with 2 m(6.5')cable|
|A000032|19 mm(0.75")connector with 5 m(16')cable|
|A000040|Metal foil filter 2μm withprotective cap,black|
|A000042|Oleophobic foil filter 0.7μm with blackprotective cap|
|**Mounting**||
|A000110|3/4" NPT SS adj. fittingfor SSprobes|
|A000100|Al mountingflange for Ø19 mm(0.75")SSprobes(outside Ø80 mm(3.15"))|
134
2022-V2
EcoLine Humidity and temperature transmitter
## **ORDER CODE**
To get an order code that contains all the important information, the relevant features should be selected from the tables below and the ordered in sequence (starting with the basic model): "Feature A" + "Feature B" + "Feature C" + "Feature D" + "Feature E" + "Feature F" + "Feature G"
## **Example:** DT722 + SX + A + T0 + 03 + CA + F02
Relative humidity and temperature transmitter without digital display. Output signals for absolute humidity and temperature (0...100 °C). Probe length is 300 mm. Without mating connector and without cable. 19 mm open protective cap in black. **DT722 SX A T0 03 CA F02 Base Unit {Feature A} Filter {Feature G}** Relative humidity and 19 mm (0.75") slotted protection DT722 F02 temperature cap black 19 mm (0.75") PVDF filter F15 **Display {Feature B}** with protection cap Display SD 19 mm (0.75") mesh filter F21 No display SX with protection cap 19 mm (0.75") arrow SS sintered F25 ~~=a~~ **Moisture Signal {Feature C)** filter 5 μm 19 mm (0.75") arrow SS sintered Relative humidity H F27 filter 20 μm Calculated dp temp (range (Td)) -40...60 °C (-40...140 °F) D 19 mm (0.75") foil filter 2 μm F40 with protection cap, black Calculated absolute humidity (Abs) A Oleophobic foil filter 0.7 μm F42 with protection cap, black (range Abs from 0...200 g/m[3] ) Calculated wetbulb temp (range W **Cable {Feature F}** (Tw) - 40...60 °C (-40...140 °F) No Cable CA 19 mm (0.75") connector, **Temperature {Feature D}** no cable, w/screw terminal CB 0...100 °C (32...212 °F) T0 19 mm (0.75") connector CC -40...150 °C (-40...302 °F) TS with 2 m (6.5') cable Other output scaling available TX 19 mm (0.75") connector CD on request with 5 m (16') cable ~~aa~~ l ~~l=~~ **Length {Feature E}** 200 mm (7.87") probe 02 300 mm (11.81") probe 03 500 mm (19.69") probe 05 900 mm (35.43") probe 09
## **COMPATIBILITY**
- DT722 Transmitters are **not** compatible with Rotronic HC2A probes
- The only compatible accessories and spare parts like filters, protection caps, mounting clips etc. are listed here.
- In case of insecurity, please contact your local Rotronic partner.
135
2022-V2
EcoLine Humidity and temperature transmitter
## **TECHNICAL INFORMATION**
|**Performance**|**Performance**|**Performance**|**Performance**|
|---|---|---|---|
|Measurement range(RH)|0...100 %rh|||
|Measurement range(T)|-40...150 °C(-40...302 °F)|||
|Accuracy @25 °C(77 °F)humidity|< ±2 %rh(5...95 %rh)|||
|Accuracy @ 25 °C (77 °F)<br>temperature|±0.2 °C (±0.36 °|||
|||F) typical||
|Stability– RH sensor<br>Resonse time – RH sensor|±1 %rh/year<br><10 sec typical|||
|p<br>(for 90 % of the<br>**Electrical specifications**||stepchange)||
|Output signal|4...20 mA|||
|Supplyvoltage|8...32 V DC|||
|Supplyvoltage influence|±0.01 %rh/V typical|||
|**Operating humidity**||||
|Operating humidity probe,<br>housing,storage|10...95 %rh (non-condensing)|||
|**Operating temperatures**||||
|Probe|-40150 °C(-40302 °F)|||
|Housing<br>Storage|......<br>-20...70 °C(-4...158 °F)<br>-30...75 °C(-22...167 °F)|||
|**Mechanical specifications**<br>Ingressprotection<br>IP65(NEMA 4 level)||||
|Housingmaterial|Stainless steel|||
|Weight|200 mm/800 g (7.87"/28.22 oz)<br>300 mm/900 g (11.81"/31.75 oz)<br>500mm/1040 g (19.69"/36.68 oz)<br>900 mm/1412g (35.43"/49.80 oz)|||
|Electrical connections|5pin,M12|||
Subject to technical change without notice. Printing and other errors reserved.
136
2022-V2
EcoLine Humidity calibrator
## S904
## **BENEFITS**
- Simple operation and maintenance
- Excellent chamber stability and uniformity
- Manual control or optional straightforward automated set point programming
- Optional in-built data-logging for reference probe and probes under calibration
## **APPLICATIONS**
- On-site or in-lab verifications
- Validation of RH probes at pharmaceutical manufacturing facilities, meteoritical offices, food manufacturing etc.
## **Description**
## **GENERAL**
The S904 is a completely stand-alone and transportable calibrator for humidity sensors, requiring no external services other than mains power. The calibration chamber features 5 interchangeable ports to accommodate virtually any brand, type or model of sensor. This calibrator is ideal for companies or organizations looking to calibrate large numbers of probes in a laboratory or field setting.
## **FAST RESPONSE TIME**
Two highly visible LED panels on the front of the S904 display the current humidity and temperature within the calibration chamber. The response time to a humidity or temperature step change is typically less than 10 minutes, so a simple 3-point calibration can be carried out in under an hour.
## **MAINTENANCE**
## **HIGH STABILITY**
The environment within the insulated calibration chamber is temperature controlled using a 4-zone fan-assisted Peltier arrangement for maximum stability, and minimum temperature gradient. The humidity of the circulating air is precisely regulated using a closed-loop control system that functions by proportionally mixing flows of dry and saturated air.
The S904 is easy to maintain. The desiccant changes color to indicate when it needs to be recharged and this is visible through a clear window on the front of the unit. Recharging the desiccant is simply a matter of heating it in a conventional oven at +150°C (+302°F) for 3 hours. The water reservoir at the front of the unit shows the current saturator fill level and makes it easy to top-up with distilled water when required.
137
2022-V2
EcoLine Humidity calibrator
## **ACCESSOIRES & SPARE PARTS**
|**Order Codes**|**Product/ Description**|
|---|---|
|**Doors and Door Ports**||
|A000266|Door with clear window - noports|
|A000268|Door withoutports|
|A000263|Door with 5ports –please order adaptors separately|
|A000264|Door kit with 5 ports and 25 adapters - 5 x Ø19 mm (0.75”), 4 x Ø12 mm (0.47”), 4 x Ø13.5 mm (0.53”),<br>4 x Ø15 mm(0.59”),4 x Ø18.5 mm(0.73”),4 x Ø24 mm(0.94”)– and 25 blind stops. Adapter tool included|
|A000369|Door kit for use with MI OptidewOPT401/501. (Optidew dew-point sensor port opening,<br>PRTport adapterplus 3 x Ø standard sized adapters. Adapter tool included)|
|A000279|Polymer adapter Ø19 mm to Ø6 mm PRT|
|A000290|Moldedpolymerport adapter & blind stop (to be modified bycustomer) (M30x1)|
|A000290X|Polymerport adapter Ø client specific & blind stop (checkpossibilitywith factoryfirst)|
|A000291|Polymerport adapter for Ø12.0 mm(0.47") probe,blind stop (M30x1)|
|A000292|Polymerport adapter for Ø13.5 mm(0.53") probe,blind stop (M30x1)|
|A000293|Polymerport adapter for Ø14.0 mm(0.55") probe,blind stop (M30x1)|
|A000294|Polymerport adapter for Ø15.0 mm(0.59") probe,blind stop (M30x1)|
|A000295|Polymerport adapter for Ø18.5 mm(0.73") probe,blind stop (M30x1)|
|A000296|Polymerport adapter for Ø19.0 mm(0.75") probe,blind stop (M30x1)|
|A000297|Polymerport adapter for Ø24.0 mm(0.95") probe,blind stop (M30x1)|
|A000298|Polymerport adapter for Ø25.0 mm(0.98") probe,blind stop (M30x1)|
|A000377|Blind stopfor Optidew 2 opening|
|A000378|Blind stopfor Optidew 2 Ø6 mm opening|
|A000265|Tool for changingtheport adapters|
|**Miscellaneous**||
|A000240|Dryingmodule(includingdesiccant)|
|A000242|Water bottle|
|A000171|0.25 kg (0.55 lbs)desiccant(orange)|
|A000172|3 kg (6.6 lbs)desiccant(orange)|
|HT961T00|Control sensor. (Please add to order of control sensor, which type of calibration is preferred.<br>See calibration RH tab for choice of calibration andprices)|
|OCAL-TC|Transport Case for OptiCal and S904|
|S8K-REM-TSG|S8000 Remoteguard for use in S904 and Optical|
## **SOFTWARE**
An optional integrated digital interface is available only for the S904-D. This allows the humidity and temperature set points of the chamber to be controlled with the supplied PC application software, enabling the operator to create completely automated calibration profiles for unattended laboratory operation. The software also gives the ability to monitor, chart and log data from the connected probes and calibration reference on a PC for later analysis. Alternatively, the set points can be controlled manually with the front panel controls − making the S904 ideal for field calibrations where a PC is not available.
138
2022-V2
EcoLine Humidity calibrator
## **TECHNICAL INFORMATION**
Dimemsions
**==> picture [226 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
520.0 mm (20.47")<br>290.0 mm (11.4")<br>**----- End of picture text -----**<br>
**==> picture [193 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
420.0 mm (16.5")<br>290.0 mm (11.4")<br>**----- End of picture text -----**<br>
|**Humidity**|**Humidity**|
|---|---|
|Generation range|10...90 %rh|
|Accuracy<br>Control element|≤±1 %rh (10...70 %rh)<br>≤±1.5 %rh(70...90 %rh)|
|Stability|±0.2 %rh(20...80 %rh)|
|**Temperature**||
|Generated range|10...50 °C (50...122 °F)<br>(lowest T set point = 10 °C (18 °F)<br>below ambient)|
|Accuracy|±0.1 °C(±0.2 °F)|
|Stability|±0.1 °C(±0.2 °F)|
|**Chamber**||
|Ramp rate from<br>20...40 °C (68...104 °F)<br>40...20 °C(104...68 °F)|1.5 °C / minute (2.7 °F / minute)<br>0.7 °C/minute(1.2 °F/minute)|
|Control element|Removable relative humiditysensor|
|**General**||
|Probe ports|Up to 5 – sensor body diameters 5 to<br>25 mm (0.2 to 0.98”) accommodated<br>by port adapters|
|Chamber volume|2000 cm3 (122.1 in3)|
|Chamber dimensions|105 x 105 x 160 mm (4.13 x 4.13 x<br>6.3”) (h x w x d)|
|Instrument dimensions|290 x 520 x 420 mm (11.4 x 20.5 x<br>16.5”) (h x w x d)|
|Setpoint resolution|0.1 for humidityand temperature|
|Displays|3 digit LED,10 mm(0.39”)characters|
|Supply|85...264 V AC,47/63 Hz,150 VA|
## **CHAMBER DIMEMSIONS**
**==> picture [173 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
105 mm<br>160 mm<br>105 mm<br>**----- End of picture text -----**<br>
139
2022-V2
**Humidity and Temperature Temperature Differential pressure CO2 Applications Rotronic Monitoring System – RMS Software EcoLine – Humidity & Temperature Services** a **Theory**
**Video HygroGen2** Interested? Then scan the QR code! ~~eeed ee [a~~ l **Video mapping** Interested? Then scan the QR code!
140
2022-V2
Services Consultation, Validation, Calibration
## GxP consultation
## **We place our knowledge at your disposal.**
With our consulting services in GxP, we support you from project planning (URS) to implementation and testing of your system. This ensures an optimal and efficient design.
The individuality of your application may require a variety of function-specific settings and measurement systems. Rotronic is one of the leading suppliers in the world for humidity and temperature measurement equipment. Benefit from our know-how and let our application engineers design the optimal measuring system for you.
## Validation & qualification
## **FDA CFR 21 Part 11 is not just a title.**
Validation is a process for creating documents that show that a procedure, process or activity maintains the desired level of compliance at all stages.
Missing information and poorly specified or inadequately tested systems represent a risk and can lead to high maintenance costs and losses in productivity.
## **Rotronic supports you in all areas relating to validation:**
1. Development of SOP for system validation
2. Preparation of project-related validation plans and risk analyses
3. Preparation of IQ/OQ-PQ documents
4. Preparation of validation reports
**==> picture [14 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
Risk Management / Design ReviewChange and Configuration Management<br>**----- End of picture text -----**<br>
5. And others
**==> picture [71 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
V-model (validation)<br>**----- End of picture text -----**<br>
## **Your benefits**
**Queries**
- Competence in validation directly from the manufacturer
support-rh@rotronic.ch
- FDA/GAMP-compliant systems
141
2022-V2
Services Consultation, Validation, Calibration
## On-site calibration ISO 9001
## **Benefit from our mobile calibration facilities.**
You do not like long downtimes of your measuring equipment/test equipment? Then why not take advantage of our offer to calibrate your measuring equipment at your premises. Our calibration engineers will come to your production line/facilities/premises with portable humidity & temperature generators and calibrate your measuring equipment with minimum downtime.
If you do not wish to have external work carried out on your production lines/facilities/premises directly due to its disruptive nature, we will park in front of your company and calibrate your measuring and testing equipment in our air-conditioned calibration mobile. For further information, please go to: www.kalibriermobil.com
## ISO 9001 calibration (laboratory)
## **Customers have relied on our know-how in calibration since 1965.**
In our factory calibration laboratory, we operate systems according to standardized procedures, documented in accordance with ISO 9001, enabling us to ensure top and consistent calibration quality and to guarantee same to our customers. Ongoing communication between the SCS laboratory (ISO 17025) and the calibration team for factory calibrations increases the knowledge of both teams and benefits the customer!
Further, as manufacturer of the internationally known humidity & temperature generator HygroGen HG2, we are able to offer our experience not only to end customers but also to competitors as users of our know-how and equipment.
## ISO 17025 calibration
## **The Swiss Rotronic ISO 17025 laboratory has existed since 1995 benefit from our experience.**
In our SCS 0065 accredited calibration laboratory, we offer the highest and traceable accuracy for your temperature and relative humidity measurement devices. The accuracy of measuring instruments can only be confirmed by regular calibration. Rotronic operates its state-of-the-art calibration laboratory (ISO 17025 accredited) with efficiency and the highest quality.
All our references are traceable to the national standard with excellent measurement uncertainty. We calibrate Rotronic instruments as well as third-party products.
## **Accredited calibration laboratories worldwide**
- Switzerland: SCS 0065 calibration laboratory
- ISO 17025 accredited by SAS and traceable to the national standard
**==> picture [146 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
International<br>SI unit<br>unit<br>National standard<br>METAS<br>Accredited body SCS 0065<br>Factory calibration<br>Consumer Consumer<br>**----- End of picture text -----**<br>
- Germany: SCS 0065 calibration laboratory
ISO 17025 accredited by SAS and traceable to the national standard.
Calibration hierarchy (e.g. Switzerland)
- England: UKAS 0766 calibration laboratory
- ISO 17025 accredited by UKAS and traceable to NPL
- USA: Cert. no. 5622.01 calibration laboratory ISO 17025 accredited by A2LA and traceable to NIST
## **Your benefits**
- Higher confidence and recognition of calibration certificates by auditors (ISO 17025)
## **Queries**
calibration@rotronic.ch
- Highly accurate SCS calibration (ISO 17025)
- Expedited calibration available
142
2022-V2
Services Mapping ~~CPST~~
## Mapping of warehouses, climate chambers, rooms, etc.
## **Incorrect climatic conditions can result in expensive damage to your products.**
The protection of the quality of temperature-sensitive products during transport and storage is an important and essential component of the GxP directive. The basis for observance of legal regulations is GxP-compliant qualification of the transport equipment or storage facility. We have specialized in these services and offer you an efficient solution tailored exactly to your requirements for:
- Storage rooms
- GxP clean rooms
**==> picture [155 x 131] intentionally omitted <==**
**----- Start of picture text -----**<br>
Producer Logistics Wholesale<br>Loading Unloading Last mile<br>Provisioning<br>Storage<br>Picking<br>Transport<br>Warehouse Warehouse<br>Process<br>Risk<br>**----- End of picture text -----**<br>
- Fridges
- Freezers
- Trucks
Risk assessment for shipping of pharmaceutical products
- Shipping boxes
- And many more
## **Take advantage of our all-round service:**
- Advice on compliance with official requirements
- Placement/Distribution of the calibrated Rotronic data loggers
- Evaluation and interpretation of the climatic conditions measured
- Preparation of a GxP-compliant report incl. delivery of the calibration certificates for the loggers used
- A Rotronic qualification engineer will explain and substantiate the GxP-compliant data directly on customer request in the case of a possible audit
Example view of a temperature and humidity mapping
Temperature Temperature mapping warehousmapping production es rooms
Temperature Temperature mapping climate mapping transport chambers
## **Your benefits**
- Exact data on the climate in the room
- Mapping conforming to FDA & GxP
- Knowledge of possible danger zones in the controlled climate
## **Services**
- Warehouse qualification and validation (climate mapping)
- Transport qualification
- Climate chamber mapping
- Maintenance and installation of measuring systems
## **Queries**
- On-site calibrations
support-rh@rotronic.ch
143
2022-V2
Services Seminar, Repair ~~ee~~
## Calibration seminar & training
## **Experience is the best teacher tap into our wealth of experience!**
Our seminars are used by customers working in various fields to refresh their knowledge or to learn the basics of, for example, calibration.
They benefit from, for example, calibrations carried out in practice and apply the knowledge they have acquired immediately. A calibration seminar can be held in the Rotronic training room or carried out at your premises.
## **Topics:**
- Principles of humidity and temperature measurement
- Principles of sensor technology and calibration
- How often should/must calibration be performed?
- What are the pitfalls in calibration?
- Open discussion on your application
- Practical exercises
## Repair & maintenance
## **If it makes sense, we will gladly reduce the mountain of equipment to be disposed of.**
Once you have opted for a measurement instrument from Rotronic, you will soon discover you are working with a solution that offers an unmatched benefit: long-term stability!
If, however, your instrument becomes damaged, you can rely on a fast, high-quality and customerorientated after sales service from Rotronic.
144
2022-V2
Services Equipment hire
## Equipment hire to customers
**Rent instead of buying – our equipment is waiting for you.**
## **HygroGen2 (HG2-S) humidity and temperature generator** ~~SEE~~
Many customers have their measuring instruments calibrated in our accredited laboratory others prefer to perform the calibration themselves. Rotronic provides the HygroGen2 humidity and temperature generator for on-site calibrations.
Renting the device saves you investment in your own instrument and you receive equipment with outstanding accuracy that is traceable to our SCS (ISO 17025) laboratory at all times. Calibrate your Rotronic or third-party probes with the easy-to-use HygroGen humidity and temperature generator.
If you initially feel a little unsure, simply hire a Rotronic technician as well. He will explain the calibration procedure to you and help you with your first own calibrations/adjustments.
## **Features of the HG2-S:**
- Generates a stable reference environment (humidity and temperature)
- Calibration solution for the laboratory and on-site
- Humidity equilibrium typically in only 5 minutes
- Calibrates up to 6 probes simultaneously
- Integrated touch screen PC with 9 USB ports
- Integrated FDA 21 CFR Part 11-compliant Rotronic HW4 software
- Range 5…95 %rh (2...99 %rh with range extension option) 0…60 °C
## **HL-1D data logger**
We also rent out data loggers for short-term use. The humidity and temperature data are recorded in an interval defined by you.
## **Typical applications for the HL-1D data logger are:**
- Humidity and temperature monitoring in storage and production rooms
- Humidity and temperature mapping in product packaging, cooling systems, shipping processes, etc. for foods and other sensitive products
The HL-1D data logger records your data in a definable interval of time. Please contact your local Rotronic representative if you are interested.
## **Your benefits**
## **Queries**
- Low maintenance costs for measuring systems
support-rh@rotronic.ch
- High availability of replacements
- Short production downtimes
- Pick-up service by arrangement
145
2022-V2
|**Humidity and Temperature**|||
|---|---|---|
|**Temperature**|||
|**Differential pressure**|||
|**CO2**|||
|**Applications**|||
|**Rotronic Monitoring System – RMS**<br>@|||
|**Software**|||
|**EcoLine – Humidity & Temperature**|||
|**Services**|||
|**Theory**<br>GD|||
146
2022-V2
Theory Measurement parameters: fundamentals ~~st~~
## Fundamental terms of humidity measurement
## **Water vapor density (absolute humidity)**
This is the amount of water vapor (kg) contained per unit volume (m[3] ) of the gas mixture. In a gas mixture the water vapor generates a certain partial pressure that is part of the total barometric gas pressure. The vapor pressure can only rise to its saturation limit, which is determined by the temperature. Thereafter water is given off in liquid form (dew). The maximum pressure is called saturation pressure and is temperature dependent. The temperature dependency is, however, not included in the term of absolute humidity.
## **Relative humidity**
Relative humidity is the relationship between the actual water vapor pressure and the maximum possible water vapor pressure.
p %rh = 100[• ] ps
- %rh: Relative humidity percentage
p: Water vapor pressure in the gas mixture at ambient temperature
ps: Water vapor saturation pressure at ambient temperature
100 %rh corresponds to the maximum amount of water vapor a gas mixture can contain at constant pressure and constant temperature. At constant water vapor partial pressure and changing ambient temperature, the water vapor saturation pressure changes and consequently the relative humidity also changes (see water vapor saturation pressure).
To obtain useful measurements of relative humidity, it is extremely important that the measurement probe and measured material have the same temperature.
## **Equilibrium relative humidity (ERH)**
A hygroscopic material always tries to reach humidity equilibrium with the surrounding air. Equilibrium relative humidity is the free water content in a hygroscopic material after equilibrium is reached in an environment with constant relative humidity and temperature.
Humidity equilibrium then prevails when the amount of water absorbed and given off is equal.
## **Response time of Rotronic sensors**
Rotronic defines the response time of its sensors as the time taken to complete 63% of a step change in humidity levels. The response time becomes greater at low temperatures and low air movement. It also increases when a filter is used as the water vapor is transported through the filter more slowly due to the reduced air flow and the water exchange takes place with slower diffusion of the water molecules.
**Video Humidity** ~~—_aH_—JTYH—@]—~~
Interested? Then scan the QR code!
147
2022-V2
Theory Measurement parameters: fundamentals
## Psychrometric parameters
## **Dew point / Frost point (Dp / Fp)**
The dew point is the temperature at which the air over water is saturated with water vapor at a constant air pressure. The water vapor pressure that then prevails is the same as the water vapor saturation pressure.
## **Wet bulb temperature (Tw)**
This is the lowest temperature that can be reached by evaporative cooling. The water given off by a wet surface is then in equilibrium with the water absorption capacity of the surrounding atmosphere.
## **Enthalpy (H)**
To obtain useful measurements of relative humidity, it is extremely important that the measurement probe and measured material have the same temperature. The specific enthalpy of moist air is an energetic property. It is composed of the specific enthalpies of the components in the mixture (dry air, water vapor) and is related to the mass fraction of the dry air. It is given in J/kg.
## **Specific humidity (Q) in g/kg**
This is the ratio of the mass of the water vapor to the mass of the complete gas mixture containing the water vapor.
## **Vapor concentration (Dv) in g/m[3]**
This is the ratio of the mass of the water vapor to the volume of the complete gas mixture containing the water vapor.
## **Mixing ratio (R) in g/kg**
This is the ratio of the mass of the water vapor to the mass of the dry gas mixture containing the water vapor.
## **Water vapor partial pressure (E) in hPa**
This is the fraction of the total pressure of a gaseous mixture due to water vapor.
## **Water vapor saturation pressure (Ew) in hPa**
This is the maximum pressure that water vapor can reach over a water surface at a given temperature.
## **Mean kinetic temperature (MKT)**
The mean kinetic temperature is the total influence of temperature on an object or product over a certain period of time.
148
2022-V2
Theory Measurement parameters: fundamentals
## Probe use in practice
**As a world-leading manufacturer of humidity measurement instruments, Rotronic is fully aware of its responsibility to offer instruments that can withstand the harshest operating conditions, while remaining user-friendly and requiring minimal maintenance. At the same time we urge our users to ensure excellent performance of the measurement instruments at the expense of little effort. The following checklist is provided as a guide.**
1. Analyze the environment in which the humidity probe is used. What suspended substances and/or chemicals exist and in what concentration?
2. Install the probe at a place representative of the measured climate with good airflow across the sensor.
3. Choose the right filter. Measurement is fastest without a filter. For wind velocities higher than 3 m/s, however, a filter must be used. The filter protects the sensor up to airflow velocities of 40 m/s. Suitable filters must also be used in the case of contaminants/pollutants
- and in harsh environmental conditions.
4. Install the probe correctly to suit the application.
5. Inspect and replace the filter more frequently in harsh operating conditions. Filters can be cleaned in an ultrasonic bath. However, always keep a new filter set in stock.
6. Check that the measurement probe is working correctly by performing a calibration at least every 6 to 12 months.
7. For calibration, use one of our calibration services or the SCS-certified humidity standards. This will ensure your calibration is traceable to national standards.
## PT100 temperature sensors
A PT100 sensor changes its electrical resistance with every change in temperature in its environment. Its resistance value is 100 Ohms at 0 °C. This characteristic is used in a bridge circuit to generate a signal suitable for further processing. There are five quality classes with the following tolerances at 0 °C.
Class B: ±0.3 K Class A: ±0.15 K Class B 1/3: ±0.1 K Class B 1/5: ±0.06 K Class B 1/10: ±0.03 K
The table below illustrates the tolerances for each PT100 sensor class at different temperatures.
**==> picture [513 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
Tolerance<br>Class A Class B 1/3 Class B 1/5 Class B 1/10 Class B<br>Temp. °C ± K ± Ω ± K ± Ω ± K ± Ω ± K ± Ω ± K ± Ω<br>-200 0.55 0.24 1.3 0.56 0.44 0.19 0.26 0.11 0.13 0.06<br>-100 0.35 0.14 0.8 0.32 0.27 0.11 0.16 0.06 0.08 0.03<br> 0 0.15 0.06 0.3 0.12 0.1 0.04 0.06 0.02 0.03 0.01<br>100 0.35 0.13 0.8 0.3 0.27 0.1 0.16 0.05 0.08 0.03<br>200 0.55 0.2 1.3 0.48 0.44 0.16 0.26 0.1 0.13 0.05<br>300 0.75 0.27 1.8 0.64 0.6 0.21 0.36 0.13 0.18 0.06<br>400 0.95 0.33 2.3 0.79 0.77 0.26 0.46 0.16 0.23 0.08<br>500 1.15 0.38 2.8 0.93 0.94 0.31 0.56 0.19 0.28 0.09<br>600 1.35 0.43 3.3 1.06 1.1 0.35 0.66 0.21 0.33 0.1<br>650 1.45 0.46 3.6 1.13 1.2 0.38 0.72 0.23 0.36 0.11<br>**----- End of picture text -----**<br>
## **New standard**
The manufacturing tolerances were formerly sub-divided into the accuracy Classes A and B (see above). The new standard contains the additional classes AA and C. Within the validity range of every class for wire-wound resistors and film resistors, the limit deviations (tl) are given in dependence on the temperature (t) in Celsius:
Class AA: tl = 0.1 K + 0.0017 · t Class A: tl = 0.15 K + 0.002 · t Class B: tl = 0.30 K + 0.005 · t Class C: tl = 0.6 K + 0.01 · t
Example for Class B: At 200 °C deviations in the measured value of up to ± 1.3 K are allowed.
149
2022-V2
Theory Measurement parameters: fundamentals
## Accuracy of HC2A probes
## **ACCURACY SPECIFICATION FOR HUMIDITY AND TEMPERATURE**
With its accuracy specification, Rotronic states the maximum permissible deviation of the HygroClip probe from the Rotronic SCS reference. The accuracy specification applies at the adjusted humidity and temperature values.
A validated and permanently monitored process guarantees that all HygroClip probes undergoing production match the Rotronic references used. In addition to this, samples are taken from every production batch and checked for accuracy against SCS references.
## **Humidity**
## **ACCURACY OF HUMIDITY MEASUREMENTS OVER THE MEASURING RANGE**
## **HygroClip2 industrial probes**
HC2A-IC / HC2A-IM / HC2A-IE
## **HygroClip2 probes**
HC2A-S(3) / HC2A-SM
## **Continuous load**
Rotronic HC2A industrial probes are designed for continuous loads of up to 190 °C. Rotronic standard probes up to 100 °C.
## **1 Peak load:**
The peak load at 200 °C is 100 h. See the sensor data sheet for detailed information on the pollution loads for the sensor.
**==> picture [249 x 197] intentionally omitted <==**
**----- Start of picture text -----**<br>
HC2A-IC<br>(%rh) HC2A-S<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>-100 - 80 - 60 - 40 - 20 0 20 40 60 80 100 120 140 160 180 200 (°C)<br>Peak load: 100 h 1<br>± 4.5 %rh ± 3.3 %rh ± 2.3 %rh ± 1.3 %rh ± 0.8 %rh ± 1.3 %rh ± 1.8 %rh ± 2.8 %rh<br>**----- End of picture text -----**<br>
## **Temperature**
## **ACCURACY OF TEMPERATURE MEASUREMENTS OVER THE MEASURING RANGE**
## **HygroClip2 industrial probes**
HC2A-IC / HC2A-IM / HC2A-IE
## **HygroClip2 probes**
HC2A-S(3) / HC2A-SM
**==> picture [249 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
HC2A-IC<br>HC2A-S<br>0.5<br>0.4<br>0.3<br>0.2<br>0.1<br>0.0<br>-0.1<br>-0.2<br>-0.3<br>-0.4<br>-0.5<br>-100 - 80 - 60 - 40 - 20 0 20 40 60 80 100 120 140 160 180 200 (°C)<br>**----- End of picture text -----**<br>
150
2022-V2
Theory Measurement parameters: fundamentals
## Contaminants/Pollutants
Some gases and contaminants/pollutants can damage Rotronic humidity sensors. The contaminants/pollutants can be divided into two categories: gases without influence and gases with an influence on the humidity sensors.
For contaminants/pollutants with an influence on the sensors and therefore with an influence on the measurement result, the maximum constant concentration must be known (see table below).
## **Contaminants/Pollutants with an influence**
**==> picture [512 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
Contaminant/Pollutant Formula MAC value Permissible constant concentration<br>IN-1 HH-1 HT-1<br>ppm mg/m [3] ppm mg/m [3] ppm mg/m [3] ppm mg/m [3]<br>**----- End of picture text -----**<br>
|**Contaminant/Pollutant**|**Formula**|**MAC value**|**MAC value**|**Permissible constant concentration**|**Permissible constant concentration**|**Permissible constant concentration**|**Permissible constant concentration**|**Permissible constant concentration**|**Permissible constant concentration**|
|---|---|---|---|---|---|---|---|---|---|
|||||**IN-1**||**HH-1**||**HT-1**||
|||**ppm**|**mg/m3**|**ppm**|**mg/m3**|**ppm**|**mg/m3**|**ppm**|**mg/m3**|
|||||||||||
|Acetone|CH3COCH3|1000|2400|3300|8000|3700|9000|3300|8000|
|Ammonia|NH3|25|18|5500|4000|5500|4000|5500|4000|
|Petrol||300|1200||150000||150000||150000|
|Chlorine|Cl2|0.5|1.5|0.7|2|1.5|4.5|0.7|2|
|Acetic acid|CH3COOH|10|25|800|2000|1000|2500|800|2000|
|Ethyl acetate|CH3COOC2H5|400|1400|4000|15000|4000|15000|4000|15000|
|Ethanol|C2H5OH|1000|1900|3500|6000|5800|10000|3500|6000|
|Ethyleneglycol|HOCH2CH2OH|100|260|1200|3000|1200|3000|1200|3000|
|Formaldehyde|HCHO|1|1.2|2400|3000|2400|3000|2400|3000|
|Isopropanol|(CH3)2CHOH|400|980|4800|12000|6000|15000|4800|12000|
|Methanol|CH3OH|200|260|3500|6000|6000|8000|3500|6000|
|Methyl ethyl keton|C2H5COCH3|200|590|3300|8000|3300|8000|3300|8000|
|Ozone|O3|0.1|0.2|1|2|1.5|3|1|2|
|Hydrochloric acid|HCl|5|7|300|500|300|500|300|500|
|Sulfr dioxide|SO2|5|13|5|13|5|13|5|13|
|Hydrogen sulfde|H2S|10|15|350|500|350|500|350|500|
|Nitrousgases|NOx|5|9|5|9|5|9|5|9|
|Toluene|C6H5CH3|100|380|1300|5000|1800|7000|1300|5000|
|Hydrogenperoxide|H2O2|1|1.4|90|130|880|1200|90|130|
|Xylene|C6H5(CH3)2|100|440|1300|5000|1800|7000|1300|5000|
## **Contaminants/Pollutants without influence**
Note that the common sealing material silicone damages the sensor! When probes are installed, silicone must not be used!
|**Contaminant/Pollutant**|**Formula**|
|---|---|
|Argon|Ar|
|Butane|C4H10|
|Naturalgas||
|Ethane|C2H6|
|Helium|He|
|Methane|CH4|
|Neon|Ne|
|Propane|C3H8|
|Oxygen|O2|
|Nitrogen|N2|
|Hydrogen|H2|
151
2022-V2
Theory Measurement parameters: fundamentals ~~PST~~
## Water activity
The measurement of water activity or equilibrium relative humidity (ERH) is a key parameter in the quality control of moisture sensitive products or materials. Water activity is by definition the free or non-chemically bound water in foods and other products. The bound water cannot be measured with this method.
## **WHY IS WATER ACTIVITY MEASURED?**
The free water in a product influences its microbiological, chemical and enzymatic stability. This is especially important in the case of perishable products such as foodstuffs, grain, seeds, as well as for many products in the pharmaceutical and cosmetic industries. If there is too much free water available, the products spoil, and if there is too little water available, other product properties can be influenced negatively.
The table shows typical growth thresholds below which the specified organism cannot reproduce and therefore spoil the product. Control of water activity therefore has a significant impact on the shelf life of a product.
The measurement of water activity also provides useful information on properties such as the cohesion, storage life, agglomeration or pourability of powders, tablet stability, and the adherence of coatings.
|**Water activity**|**Contaminant**|
|---|---|
|aw = 0.91..0.95|Manybacteria|
|aw = 0.88|Many yeasts|
|aw = 0.80|Manymildews|
|aw = 0.75|Halophile bacteria|
|aw = 0.70|Osmiophileyeasts|
|aw = 0.65|Xerophile mildew|
The Rotronic water-activity probes work with digital HygroClip technology, which ensures their high performance and simple, digital calibration. They can therefore be used in practically all fields of application.
All water activity stations and probes incorporate temperature measurement as a standard feature. The water activity measurement stations measure in a range of 0…1 aw, which equates to 0…100 %rh, and supply a digital output signal, which can be displayed directly on a PC (HC2AW-USB) or the HygroLab C1 and HP23-AW-A display units.
Digital calibration can be performed with these instruments or with HW4 software running on a PC. The HC2-AW probes have a large thermal mass. This means they react very slowly to temperature changes so that virtually no variations arise during measurement – especially when using the AW Quick function. The extremely small internal volume of the sensor chamber ensures humidity equilibrium is reached very quickly for all products.
**Video water activity** ~~Se~~
Interested? Then scan the QR code!
152
2022-V2
Theory Measurement parameters: fundamentals
## CO2
## **Principles**
Carbon dioxide (CO2) is a colorless and odorless gas that exists in the earth’s atmosphere and which is dangerous in high concentrations. The proportion of CO2 in natural ambient air is about 0.04 % or 400 ppm. When humans and animals exhale this gas, it is quickly mixed with the ambient air, including in rooms that are well ventilated.
A high CO2 content becomes apparent in humans through rapid fatigue and loss of concentration. The negative effects become noticeable more quickly in small rooms in which there are many people (e.g. conference rooms).
In order to initiate suitable countermeasures such as an increase in the supply of fresh air, it is important in modern climate control systems to measure not only parameters such as relative humidity and temperature, but also the CO2 content. The concentration of CO2 is regarded as an important indicator for the indoor air quality.
## **Guidelines**
350 – 450 ppm 400 – 1,200 ppm > 1,000 ppm 5,000 ppm (0.5 %) 38,000 ppm (3.8 %) > 100,000 ppm (10 %) Fresh air outdoors Room air Fatigue and Maximum permisBreathing air Nausea, vomiting, loss of concentration sible value at the (direct exhalation) loss of consciousness become apparent workplace during an and death 8-hour workday
## **Measurement technique**
The measurement technique is based on the principle of NDIR (non-dispersive infrared) sensors. This gas sensor works as a spectroscope and analyzes which wavelengths emitted by a light transmitter reach a receiver.
## **Calibration**
All probes are pre-calibrated and have a lifetime of more than 15 years in normal applications. The automatic baseline correction means the sensors require no further calibration if they are used in indoor air applications.
## **Video CO2**
Interested? Then scan the QR code!
153
2022-V2
Theory Measurement parameters: fundamentals
## Differential pressure
## **What is pressure?**
**==> picture [513 x 228] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Pressure is the physical measurement of force per unit area and is often given in the SI unit Pascal [Pa]. Other units of measurement are also very|
|widely used in pressure measurement technology. The automatic baseline correction means the sensors require no further calibration if they are|
|used in indoor air applications.|
|Conversion table|
|F|
|F|
|bar|mbar|psi|atm|p =|A|
|1.00|1,000.00|14.50|0.987|
|Pa|hPa|kPa|MPa|
|100,000.00|1,000.00|100.00|0.10|
|mmH2O|inchH2O|mmHg|inchHg|A|
|10,197.16|401.46|750.06|29.53|
|————]ar|
|What is differential pressure?|
|Three different types of pressure are generally considered in pressure measurement technology:|
|absolute pressure, relative pressure and differential pressure. Differential pressure is the drop in|Differential pressure|
|pressure between two spaces with different absolute pressures.|
**----- End of picture text -----**<br>
Differential pressure Positive pressure Negative pressure Absolute pressure = P P P (hPa)
## **Where does Rotronic measure differential pressure?**
Cleanrooms, i.e. environments in which a very low level of contamination may prevail, are pressurized slightly. This positive pressure guarantees controlled removal of dirt particles from the room. To monitor this positive pressure, one needs pressure transmitters with a very high measuring accuracy and a very low pressure measurement range. Rotronic offers such instruments.
## **How does Rotronic measure differential pressure?**
- Thermal mass flow principle
In this measurement technique, a heating element is placed between two temperature sensitive resistors. Due to a gas flow, the temperature profile is moved towards one of the resistors, which can be measured and evaluated.
- Strain gauge principle
In this technique the pressure is converted into a force, which stretches a diaphragm and
is measured by a piezo-resistive MEMS diaphragm sensor.
## **Pressure measurement technology – Glossary**
**==> picture [107 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
Heating element<br>Flow<br>Temperature-sensitive<br>resistors<br>**----- End of picture text -----**<br>
Measurement range: Pressure range in which the sensor can measure Full scale: Difference between the maximum and minimum measured pressure % Full scale: Measurement deviation in relation to full scale System pressure: Ambient pressure (often given as relative pressure, e.g. air pressure: 1013 hPa)
154
2022-V2
Theory Measurement parameters: fundamentals
## Dew point
## **What is dew point?**
As the term implies, it is the climate point at which the relative air humidity equals 100% and begins to condense. The dew point is given in °C Td. The dew point temperature is a measurement of the water vapor content in a gas. If air is compressed or expanded, its dew point temperature changes. If air is compressed, it is able to absorb less water and the dew point rises until the air is saturated and begins to condense. In this connection, the term pressure dew point measurement is also used to describe measurement of the dew point in gases above the ambient temperature.
## **What does low dew point measurement mean?**
A low dew point is usually when the dew point temperature falls below -30 °C Td. This means that the air is extremely dry and contains almost no water molecules. A dew point of -38 °C Td corresponds at 23 °C to a humidity value of 0.8 %rh, which corresponds to the accuracy of a Rotronic Hygro Clip2 probe. This shows why low dew point measurement is very demanding. Very complex electronics and a highly sensitive sensor are needed to deliver high-quality results in the measurement of residual moisture.
## **What is important in low dew point measurement?**
The measurement of such small numbers of water molecules places high demands on the measuring point. For example, it is important that there is always good airflow across the sensor so that representative measured values can be obtained. Rotronic offers a special measurement chamber for this that was developed specifically for the mechanical design of the dew point probe. Excessive flow can lead to a local pressure drop, which influences the measurement, while insufficient flow can result in measurement of a local microclimate. The constant airflow of the measurement chamber of 1 l/min. thus guarantees stable and reliable measurement results.
The equilibrium times in dew point measurements can be considerably longer than those for humidity measurements. All the materials in the system and around the sensor must be dried out. Under certain circumstances it can take hours before a low dew point system has balanced out and the residual moisture has escaped from all the materials.
## **Why is low dew point measured?**
There can be many reasons for monitoring the dew point. Compressed air systems with an excessively high dew point can condense, thereby causing valves to become blocked or corroded. In addition to this, dry compressed air systems require less maintenance, which saves costs. Equipment connected to the system places high demands on dryness and require a low dew point of the compressed air. Further, there are sensitive processes such as the drying of injection molding granulate and the compressed air for spray painting systems, which place particularly high demands on the dew point of the system. Compressed air systems can further be classified according to ISO 8573. Depending on the classification of the system, there are different dew points that need to be monitored and controlled.
**Video dew point measurement**
Interested? Then scan the QR code!
155
2022-V2
Theory Measurement parameters: fundamentals
**==> picture [466 x 709] intentionally omitted <==**
**----- Start of picture text -----**<br>
T6 85 °C<br>T5 100 °C<br>Ga/Gb Da/Db<br>Product niveau (EPL) Ga/Gb Very high protection level (Zone 0) Product niveau (EPL) Da/Db High protetion level (Zone 1)<br>T4 135 °C<br>T3 200 °C<br>T2<br>T5...T4 T110 °C<br>T80 °C...<br>Temperature class T5...T4 Max. temperature of the exposed surface of the product <100 °C T4: <135 °C / T5: <100 °C . Temperature class Max. temperature of the exposed surface of the product T80 C°...T110 C°<br>T1 450 °C 300 °C<br>Hazard Constantly, frequently or over a longer period of time Occasionally Rarely and briefly<br>IIC IIIC<br>Dust zone 20 21 22<br>Gas explosion group IIC Hydrogen, acetylene, etc. Dust classification IIIC Flammable fibres, non conductive dust, conductive dust<br>Gas zone 0 1 2 Class Max. surface temperature<br>– increased safety «e» – intrinsic safety «i» – encapsulation «m» Ex ia tb<br>Equipment protection Ex eb EN 60079-7 Ex ia EN 60079-11 Ex mb EN60079-18 Ex eb ia mb Equipment protection Ex ia – intrinsic safety «i» EN 60079-11 Ex tb – enclosure «t» EN 60079-31<br>G D<br> Product category G Gases, vapours, mists<br>Product category D Dusts<br>1/2 1/2<br>Explosion proof areas 1/2 1: Zone 0 2: Zone 1 Explosion proof areas 1/2 1: Zone 0 2: Zone 1<br>Device group II Explosive atmospheres (not mining) II II Device group II Explosive atmospheres (not mining)<br>GAS DUST<br>ATEX comes from French and stands for Atmosphères Explosibles. The aim of this directive is to protect people when working in potentially explosive environments. It comprises two directives that define explosion protection for operation and products in risk environments. Rotronic ATEX devices are based on the ATEX Product Directive 94/9/EC. How are ATEX devices specified? There are two device groups. Device group I is suitable for use in mining/above ground and under- ground. Device group II is suitable for use in other potentially explosive atmospheres. Rotronic offers devices falling in device group II. Potentially explosive environments are subdivided into zones. A distinction is drawn between whether the explosion hazard exists because of dust or gas present in the environment. Temperature classes define by how much the surface of the device may heat up in the case of a fault. This temperature is stated in the case of dust versions. Gas versions, by contrast, are subdivided into the following classes: What does the classification label of ATEX devices mean? Institute Notified Body 1258 = ElectroSuisse<br>1258<br>**----- End of picture text -----**<br>
156
2022-V2
Updated at April 24, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →