ABTWF160C0
CIRCUIT BREAKER, THERMAL, 1P, 240V, 16A
- Manufacturer: SCHURTER
- Product type: Thermal Circuit Breakers
- No. of Poles: 1 Pole
- Current Rating: 16A
- Voltage Rating VAC: 240VAC
- Voltage Rating VDC: 60VDC
- Circuit Breaker Mounting: Panel
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 18.27 € |
| Current stock | 25+ |
| Lead time | 7 days |
**CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Product description** The 2 pole, rocker actuated version of the TA45 line of thermal CBE’s can be used for various purposes. Basically it is a CBE for automatic interruption of overloads with facilities for regular manual ON/OFF switching operations under normal load conditions. It is capable of interrupting moderate short circuit currents without the aid of backup protection. A special version is available as a «CBE-switch», in which the means for automatic overcurrent interruption (the bimetal relases), are omitted. Another available version of this line utilizes an undervoltage release to protect persons against injuries caused by unexpected events like the automatic restarting of motors after a power failure. This release can be combined with the thermal release required for overcurrent protection. Protection against injuries is also provided by another CBE of this line, which prevents the starting of a machine should a protective cover be removed from dangerous parts of the machine. ## **Available options** - CBE for overcurrent protection 1 or 2 protected poles (thermal) - CBE with undervoltage release: - The CBE will open automatically when the voltage drops below the trip level. Only when the supply voltage has reached the reset level, the CBE can be reclosed manually. - CBE switch with mechanical lock-out latch: A spring loaded pin will trip the CBE if a protective cover of the equipment is removed. The CBE can not be switched ON until the protective cover is refitted. - CBE with remote trip release: The remote trip release permits the CBE to be tripped by a external contact (sensor) energizing the trip coil. - CBE with auxiliary contact: - All types of the line can be outfitted with an auxiliary contact (changeover contact). TA45 is positively trip-free. The rated current range is 0,05 to 20 A at AC 240 V / DC 60 V . The CBE comes with snap-in mounting. The rocker is available in various colours and also with illumination. It is approved in all major industrial countries and complies with the CBE-standard EN60934. In conjunction with its accessories the TA45 product line of Schurter paves the way for new unconventional applications. ## **Applications** ## **Produktebeschreibung** Die 2polige wippenbetätigte Version der TA45-Linie ist ein thermischer Geräteschutzschalter, kurz CBE (Circuit Breaker for Equipment) genannt, der für viele Zwecke eingesetzt werden kann. In seiner Grundausführung ist dieser CBE für die automatische Unterbrechung von Überlast-Strömen und das manuelle Wiedereinschalten resp. für manuelles EIN/AUS-Schalten im Normalbetrieb bestimmt. Der CBE ist in der Lage, Überströme bis zu seinem Schaltvermögen ohne back-up Unterstützung zu unterbrechen. Eine spezielle Version ist erhältlich als «CBE-switch». Bei dieser Ausführung fehlt der ThermoAuslöser. Eine weitere Version der TA45-Linie ist mit Unterspannungsauslösung ausgerüstet. Diese schützt Personen vor möglichen Verletzungen wie sie z.B. durch unbeabsichtigtes Wiederanlaufen von Geräten nach einem Netzausfall verursacht werden könnten. Dieser Schutz kann mit dem thermischen Überlast-Schutz kombiniert werden. Schutz gegen Verletzungen wird auch gewährleistet durch eine weitere Version der TA45-Reihe, die den Anlauf einer Maschine verhindert, bei der eine wichtige Schutzabdeckung fehlt. ## **Erhältliche Versionen** - Geräteschutzschalter mit Überstromauslösung: Ein- oder zweipolig geschützt durch Thermo-Bimetall - Geräteschutzschalter mit Unterspannungsauslösung: Wiederanlaufschutz bei Spannungsausfall. Nach Unterschreiten der Abfallspannung (Netzausfall) springt der Geräteschutzschalter in die AUS-Stellung. Ein manuelles Einschalten ist erst dann möglich, wenn die wiederkehrende Spannung den Anzugswert des Auslösers erreicht. - Geräteschutzschalter mit mechanischer Schaltsperre: Ein unter Federdruck stehender Stift bewirkt ein automatisches Auslösen, falls die Schutzabdekkung entfernt wird. Ein Wiedereinschalten in dieser Position ist nicht möglich, solange die Abdeckung fehlt. - Geräteschutzschalter mit Fernauslösung: Der Fernauslöser ermöglicht das Ausschalten durch einen externen Schalter oder Sensor, der die Auslösespule aktiviert. - Geräteschutzschalter mit Hilfskontakt: Alle Typen sind mit einem Hilfskontakt (Wechselkontakt) erhältlich. Der TA45 ist positiv freiauslösend. Sein Nennstrombereich beträgt 0,05 bis 20 A bei AC 240 V / DC 60 V . Die Montage erfolgt mittels Schnappbefestigung. Die Schaltwippe ist in mehreren Farben und auch beleuchtet lieferbar. Der TA45 ist in den wichtigsten Industrieländern approbiert und entspricht der neuen CBE Europa Norm EN60934. In Verbindung mit dem vielfältigen Zubehör ermöglicht der 2polige wippenbetätigte TA45 von Schurter neue unkonventionelle Anwendungen. - Motors - Power supplies ## **Anwendungen** - Processing machines - Etc. - Motoren - Netzgeräte - Be- und Verarbeitungsmaschinen - Usw. _56 www.schurter.com_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Effect of ambient temperature** ## **Einfluß der Umgebungstemperatur** The unit is calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below: Die Eichung gilt für eine Umgebungstemperatur von +23°C. Zur Bestimmung des Nennstromes für eine tiefere oder höhere Umgebungstemperatur ist ein Korrekturfaktor gemäß untenstehender Tabelle zu verwenden: |*Ambient|Correction factor| |---|---| |temperature [°C]|| |–10|0,89| |–5|0,91| |0|0,92| |+23|1,00| |+30|1,03| |+40|1,08| |+55|1,16| *UmgebungsKorrekturfaktor temperatur [°C] |–10|0,89| |---|---| |–5|0,91| |0|0,92| |+23|1,00| |+30|1,03| |+40|1,08| |+55|1,16| ## **Example** Rated current at +23°C 5,0 A Ambient temperature +40°C Correction factor 1,08 Chosen rated current at +40°C ambient temperature ## **5 A x 1,08 = 5,5 A** *Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. ## **Beispiel** Nennstrom bei +23°C 5,0 A Umgebungstemperatur +40°C Korrekturfaktor 1,08 Gewählter Nennstrom bei +40°C Umgebungstemperatur **5 A x 1,08 = 5,5 A** *Die Temperatur wird in der Nähe der Schalteranschlüsse ermittelt, nachdem das zu schützende System seine Arbeitstemperatur erreicht hat. ## **Tripping characteristics Auslösekennlinien In <3 A** ## **Tripping characteristics Auslösekennlinien 3 A** ≥ **In <18 A** **Tripping characteristics Auslösekennlinien In** ≥ **18 A** **==> picture [517 x 258] intentionally omitted <==** **----- Start of picture text -----**<br> [ min ] [ sec ] [ min ] [ sec ] [ min ] [ sec ]<br>10'000 10'000 10'000<br>Type / Typ TA45 Type / Typ TA45 Type / Typ TA45<br>Rated current Rated current Rated current<br>60 Nennstrom In <3 A1 pole protected 60 Nennstrom 3 A 1 pole protected≥ In <18 A 60 Nennstrom In 1 pole protected≥18 A<br>30 2`000 1polig geschützt2 pole protected 30 2`000 1polig geschützt2 pole protected 30 2`000 1polig geschützt2 pole protected<br>20 1`000 Ambient temp. 2polig geschützt 20 1`000 Ambient temp. 2polig geschützt 20 1`000 Ambient temp. 2polig geschützt<br>10 Umgebungstemp. +23 °C 10 Umgebungstemp. +23 °C 10 Umgebungstemp. +23 °C<br>500 500 500<br>5 5 5<br>200 200 200<br>100 100 100<br>1 1 1<br>50 50 50<br>20 20 20<br>10 10 10<br>5 5 5<br>2 2 2<br>1 1 1<br>0,5 0,5 0,5<br>0,3 0,3 0,3<br>0,2 0,2 0,2<br>0,1 0,1 0,1<br>1,05 1,32 2 3 4 5 8 10 1,05 1,32 2 3 4 5 8 10 1,05 1,32 2 3 4 5 8 10<br>Multiple of rated current [ x In ] Multiple of rated current [ x In ] Multiple of rated current [ x In ]<br>Nennstrom-Vielfaches Nennstrom-Vielfaches Nennstrom-Vielfaches<br>Auslösezeit Auslösezeit Auslösezeit<br>/Tripping time /Tripping time /Tripping time<br>**----- End of picture text -----**<br> _www.schurter.com_ _57_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Technical data / Technische Daten** **==> picture [473 x 598] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Rated voltage Ue|See approvals page 59|AC 240 V; DC 60 V| |Nennspannung Ue|Siehe Approbationen Seite 59|AC 240 V; DC 60 V| |Rated current In|See approvals page 59|AC/DC 0,05 A – 20 A| |Nennstrom In|Siehe Approbationen Seite 59|AC/DC 0,05 A – 20 A| |Conditional short circuit current Inc|EN 60934, PC1, AC 240 V|1000 A| |Bedingtes Schaltvermögen Inc|EN 60934, PC1, AC 240 V|1000 A| |Short circuit capacity Icn|AC 240 V with In<3 A|(number of cycles: 3)|10 In| |AC 240 V with In≥3 A|(number of cycles: 3)|300 A| |DC 60 V with In<3 A|(number of cycles: 3)|10 In| |DC 48 V with In ≥3 A|(number of cycles: 3)|120 A| |Schaltvermögen Icn|AC 240 V bei In<3 A|(Anzahl Schaltspiele: 3)|10 In| |AC 240 V bei In≥3 A|(Anzahl Schaltspiele: 3)|300 A| |DC 60 V bei In<3 A|(Anzahl Schaltspiele: 3)|10 In| |DC 48 V bei In ≥3 A|(Anzahl Schaltspiele: 3)|120 A| |Degree of protection|Accessible range|IP40| |With accessoris|IP54, IP65| |Terminal side|IP00| |With accessoirs|IP40| |Schutzklasse|Betätigungsbereich|IP40| |Mit Zubehör|IP54, IP65| |Anschlussbereich|IP00| |Mit Zubehör|IP40| |Dielectric strength|Accessible range|AC 4000 V| |Spannungsfestigkeit|Betätigungsbereich|AC 4000 V| |Insulation resistance|DC 500 V|>100 MΩ| |Isolationswiderstand|DC 500 V|>100 MΩ| |Endurance|Number of cycles at In (AC 240 V; DC 60 V)|50’000 x| |Number of cycles at 6 x In (AC 240 V)|40 x| |Number of cycles at 4 x In (DC 60 V)|40 x| |Lebensdauer|Anzahl Schaltspiele bei In (AC 240 V; DC 60 V)|50’000 x| |Anzahl Schaltspiele bei 6 x In (AC 240 V)|40 x| |Anzahl Schaltspiele bei 4 x In (DC 60 V)|40 x| |Permissible ambient temperature|-10°C to +55°C| |Zulässige Umgebungstemperatur|-10°C bis +55°C| |Resistance to vibration|IEC 60068-2-6, test Fc, 0.75 mm amplitude 5-60 Hz, 60-500 Hz|10 g| |Schwingungsfestigkeit|IEC 60068-2-6, Test Fc, 0.75 mm Amplitude 5-60 Hz, 60-500 Hz|10 g| |Shock resistance|IEC 60068-2-27, test Ea|30 g| |Stossfestigkeit|IEC 60068-2-27, Test Ea|30 g| |Type of tripping|• Thermal positively trip-free| |• Undervoltage release (Zero-voltage release)| |• Remote trip| |• Mechanical lock-out latch| |Auslöseart|• Thermisch positive Freiauslösung| |• Unterspannungs-Auslösung (Zero-voltage release)| |• Fernauslösung| |• Mechanische Schaltsperre| |Weight|approx. 35 g| |Gewicht|ca. 35 g| **----- End of picture text -----**<br> _58 www.schurter.com_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Technical data (continued) / Technische Daten (Fortsetzung)** **==> picture [498 x 446] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||| |---|---|---|---|---|---|---| |Auxiliary contact (changeover) / Hilfskontakt (Wechsler)| |Rated voltage|DC 28 V|DC 60 V|AC 240 V| |Nennspannung|DC 28 V|DC 60 V|AC 240 V| |Rated current|Max. 10 A|max. 2 A|max. 2 A| |resistive load|resistive load|cos ϕ 0,7| |Max. Nennstrom|Max. 10 A|max. 2 A|max. 2 A| |ohmsche Last|ohmsche Last|cos ϕ 0,7| |Undervoltage release / Unterspannungs-Auslöser| |Max. operating voltage|1,1 Ue| |Max. Betriebsspannung|1,1 Ue| |Rated operating voltage Ue|5 V|12 V|24 V|48 V|120 V|240 V| |Nennbetriebsspannung Ue|5 V|12 V|24 V|48 V|120 V|240 V| |Current consumption (±10%)|10,5 mA|16,5 mA|17,0 mA|3,2 mA|3,7 mA|3,1 mA| |Stromaufnahme (±10%)|10,5 mA|16,5 mA|17,0 mA|3,2 mA|3,7 mA|3,1 mA| |Highest reset level|0,85 Ue| |Höchste Wiedereinschaltspannung|0,85 Ue| |Lowest trip level|0,20 Ue| |Tiefste Abfallspannung|0,20 Ue| |Trip delay|20 ms – 50 ms| |Ausschaltverzug|20 ms – 50 ms| |Impuls withstand voltage (1,2 / 50 µs)|≥4 kV| |Stoss-Spannungsfestigkeit (1,2 / 50 µs)|≥4 kV| |Remote trip / Fern-Auslöser| |Permissible impuls duration| |of the make contact (no)|(Between terminal C and P1)|unlimited| |Zulässige Impulsdauer| |des Schliesskontaktes|(Zwischen den Anschlüssen C und P1)|unbegrenzt| |Electrical load| |of the make contact (no)|Current max. 12 mA / power max. 1,1 W| |Elektrische Belastung| |des externen Schliesskontaktes|Strom max. 12 mA / Leistung max. 1,1 W| **----- End of picture text -----**<br> **==> picture [34 x 250] intentionally omitted <==** ## **Approvals / Approbationen** **==> picture [514 x 183] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||| |---|---|---|---|---|---| |Rated current range|Rated voltage|Rated voltage| |Nennstrombereich|Nennspannung|Nennspannung| |AC|AC|DC| |UL|UL 1077|0,05 – 20 A|240 V|60 V| |CSA|CSA C22.2 235|0,05 – 20 A|240 V|60 V| |DVE|VDE|EN 60934|0,05 – 20 A|240 V|60 V| |SEMKO|EN 60934|0,05 – 20 A|250 V|60 V| |SEV|EN 60934|0,05 – 20 A|240 V|60 V| **----- End of picture text -----**<br> _www.schurter.com_ _59_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Order code 2 pole, rocker actuated / Bestellcode 2polig, wippenbetätigt** **==> picture [561 x 293] intentionally omitted <==** **----- Start of picture text -----**<br> Basic type Without thermal overload protection<br>Grundtyp Kein thermischer Überstromschutz<br>Auxiliary contact (changeover) / Hilfskontakt (Wechsler) •<br>Shunt terminal / Nebenanschluss<br>P2 P1 P2 P1 1110<br>6 5 6 5 12<br>Terminal type Quick connect terminal / Flachstecker • •<br>Anschlussart Screw type terminal (lineside P1, P2) • •<br>Schraubanschluss (Netzeingang P1, P2)<br>Snap-in type Dimensions / Massbilder Page / Seite 63 64 66 67<br>Schnappbefestigung<br>ON/OFF switch Without illumination ABC AHC APC ASC<br>Ein- Ausschalter Ohne Beleuchtung<br>With illumination 220 V…240 V A02 A52 AK2 A2K<br>Mit Beleuchtung 110 V…120 V A04 A54 AK4 A4K<br>20 V…26 V A07 A57 AK7 A7K<br>10 V…13 V A08 A58 AK8 A8K<br>4 V…7 V A09 A59 AK9 A9K<br>Impulse switch Without illumination AEC AJC ARC AUC<br>Taster Schalter Ohne Beleuchtung<br>**----- End of picture text -----**<br> |**Colours / Farben**|||||||||**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**|**Order example / Bestellbeispiel**<br>**Basic type / Grundtyp**||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**Switch front**<br>**Schalter-Front**||**Rocker**|**/ Wippe**||||TA45-||ABT|||W||||F|||100|||U2||||–|AZM01||| |**W**<br>black/ schwarz||white/ weiss||–|||||||||||||||||||||||||| |**1**<br>black/ schwarz<br>**B**<br>black/ schwarz<br>**R**<br>black/ schwarz<br>**3**<br>black/ schwarz<br>**G**<br>black/ schwarz<br>**4**<br>black/ schwarz<br>**Y**<br>black/ schwarz<br>**X**<br>black/ schwarz<br>**6**<br>black/ schwarz||–<br>black/ schwarz<br>red/ rot<br>–<br>green/ grün<br>–<br>yellow/ gelb<br>orange/ orange<br>–||clear transp./ natur transp.<br>–<br>–<br>red transp./ rot transp.<br>–<br>green transp./ grün transp.<br>–<br>–<br>orange transp./ orange transp.|||||||||||||||||||||||||| ||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||| |**F**<br>embossed/ Relief<br>**H**<br>printed/ bedruckt<br>white/ weiss<br>**K**<br>printed/ bedruckt<br>black/ schwarz<br>**L**<br>printed/ bedruckt<br>white/ weiss<br>**M**<br>printed/ bedruckt<br>black/ schwarz<br>**P**<br>printed/ bedruckt<br>white/ weiss<br>**R**<br>printed/ bedruckt<br>black/ schwarz<br>**S**<br>printed/ bedruckt<br>white/ weiss<br>**T**<br>printed/ bedruckt<br>black/ schwarz<br>**Surface**<br>**Illustration**<br>**Colour of print**<br>**Oberfläche**<br>**Bild**<br>**Druckfarbe**<br>**Rocker legend**<br>**Wippen-Beschriftung**<br>l<br>0<br>ON<br>OFF<br>ON<br>OFF<br>l<br>0<br>l<br>0<br>0<br>0<br>I<br>I<br>ON<br>l<br>0<br>OFF<br>ON<br>l<br>0<br>OFF|**Without thermal overload protection: code C00**<br>**Ohne thermischen Überstromschutz: Code C00**<br>**With thermal overload protection: rated current In (A)**<br>**Mit thermischem Überstromschutz: Nennstrom In (A)**<br>In<br>**Code**<br>0,05<br>**Z05**<br>0,1<br>**J01**<br>0,2<br>**J02**<br>0,3<br>**J03**<br>0,4<br>**J04**<br>0,5<br>**J05**<br>0,6<br>**J06**<br>0,7<br>**J07**<br>0,8<br>**J08**<br>0,9<br>**J09**<br>1,0<br>**J10**<br>1,1<br>**J11**<br>In<br>**Code**<br>1,2<br>**J12**<br>1,3<br>**J13**<br>1,4<br>**J14**<br>1,5<br>**J15**<br>1,6<br>**J16**<br>1,7<br>**J17**<br>1,8<br>**J18**<br>1,9<br>**J19**<br>2,0<br>**J20**<br>2,1<br>**J21**<br>2,2<br>**J22**<br>2,3<br>**J23**<br>In<br>**Code**<br>2,5<br>**J25**<br>2,8<br>**J28**<br>3,0<br>**030**<br>3,5<br>**035**<br>4,0<br>**040**<br>4,5<br>**045**<br>5,0<br>**050**<br>6,0<br>**060**<br>6,5<br>**065**<br>7,0<br>**070**<br>7,5<br>**075**<br>8,0<br>**080**<br>In<br>**Code**<br>9,0<br>**090**<br>10,0<br>**100**<br>11,0<br>**110**<br>12,0<br>**120**<br>13,0<br>**130**<br>14,0<br>**140**<br>15,0<br>**150**<br>16,0<br>**160**<br>17,0<br>**170**<br>18,0<br>**180**<br>19,0<br>**190**<br>20,0<br>**200**<br>other rated currents on request/ andere Stromwerte auf Anfrage|| |---|---|---| _www.schurter.com_ _60_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** **==> picture [562 x 352] intentionally omitted <==** **----- Start of picture text -----**<br> 1 pole thermal overload protection 2 pole thermal overload protection<br>1poliger thermischer Überstromschutz 2poliger thermischer Überstromschutz<br>• • • •<br>• • • •<br>P2 P1 P2 P1 P2 P1 1110 P2 P1 1110 P2 P1 P2 P1 P2 P1 1110 P2 P1 1110<br>3 3 3 3 4 3 4 3 4 3 4 3<br>6 6 5 6 12 6 5 12 6 5 12 6 5 12<br>• • • • • • • •<br>• • • • • • • •<br>63 64 63 64 66 67 66 67 63 64 63 64 66 67 66 67<br>ABT AHT ABF AHF APT AST APF ASF ABD AHD ABG AHG APD ASD APG ASG<br>A12 A62 A22 A72 AL2 A2L AM2 A2M A32 A82 A42 A92 AN2 A2N AP2 A2P<br>A14 A64 A24 A74 AL4 A4L AM4 A4M A34 A84 A44 A94 AN4 A4N AP4 A4P<br>A17 A67 A27 A77 AL7 A7L AM7 A7M A37 A87 A47 A97 AN7 A7N AP7 A7P<br>A18 A68 A28 A78 AL8 A8L AM8 A8M A38 A88 A48 A98 AN8 A8N AP8 A8P<br>A19 A69 A29 A79 AL9 A9L AM9 A9M A39 A89 A49 A99 AN9 A9N AP9 A9P<br>AET AJT AEF AJF ART AUT ARF AUF AED AJD AEG AJG ARD AUD ARG AUG<br>Accessories see page 62 / Zubehör siehe Seite 62<br>3 5<br>**----- End of picture text -----**<br> **==> picture [195 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> with auxiliary contact<br>mit Hilfskontakt<br>P1 a<br>3 5<br>**----- End of picture text -----**<br> **==> picture [498 x 262] intentionally omitted <==** **----- Start of picture text -----**<br> Without release / lock-out latch: code C0 Detail see pages 52 – 54<br>Ohne Auslöser / Schaltsperre: Code C0 Detail siehe Seiten 52 – 54<br>Undervoltage release Remote trip release Mechanical lock-out latch<br>Unterspannungs-Auslöser Fernauslöser Mechanische Schaltsperre<br>P2 P1 P2 b P1 P2 b a P1 P2 c P1 P2 P1<br>U< U< U<<br>Rated voltage Un<br>U* E* Z A* Code Nennspannung Un S0<br>AC (V)<br>• • • • 2 240<br>• • • • 3 230<br>• • • • 4 120<br>AC / DC (V)<br>• • • • 6 48<br>• • • • 7 24<br>• • • • 8 12<br>• • • 9 5<br>**----- End of picture text -----**<br> * Release U, E and A in combination with screw clamp terminals on request / Auslöser U, E und A in Kombination mit Schraubanschlüssen auf Anfrage _www.schurter.com_ _61_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Order code accessories 2 pole, rocker actuated Bestellcode Zubehör 2polig, wipppenbetätigt** ## **Factory mounted / werkseitig montiert** |**AZM01**|Collar with cover, 2 pole, IP54<br>Prefered type: improved seal between cover and panel| |---|---| ||Fronthaube mit Kragen, 2polig, IP54| ||Vorzugstyp: besseres Abdichten gegenüber Frontplatte| |**AZM02**|Raised collar with cover, 2 pole IP54| ||Prefered type: improved seal between cover and panel| ||Fronthaube mit Schutzkragen, 2polig, IP54| ||Vorzugstyp: besseres Abdichten gegenüber Frontplatte| |**AZM03**|Raised collar, 2 pole, IP40<br>Schutzkragen, 2polig, IP40| |**AZM10**|Collar with cover, narrow, 2 pole, IP54| ||Fronthaube mit Kragen schmal, IP54| |**AZM11**|Partially raised collar with cover, narrow, 2 pole, IP54<br>Fronthaube mit Schutzkragen schmal gegen| ||unbeabsichtigtes Einschalten der Wippe, 2polig, IP54| |**AZM12**|Partially raised collar without cover, narrow, 2 pole, IP40<br>Schutzkragen schmal gegen unbeabsichtigtes| ||Einschalten der Wippe, 2polig, IP40| |**AZM13**|Raised collar narrow, 2-pole, IP40<br>Schutzkragen schmal, 2-polig, IP40| |**AZM14**|Raised collar, with cover narrow, 2-pole, IP54| ||Fronthaube mit Schutzkragen schmal, 2-polig, IP54| Dimensions see page 65 / Massbilder siehe Seite 65 **For subsequent fitting / Nachträglich montierbar** |AZZ0<br>**Order example**<br>**Bestellbeispiel**| |---| |**AZZ04**|Screw-on collar with cover, 2 pole, IP65| |---|---| ||Fronthaube mit Schutzkragen schraubbar, 2polig, IP65| |**AZZ51**|Rear cover, 2 pole, IP40| ||Berührungsschutz rückseitig, 2polig, IP40| |**AZZ31**|Flat gasket, 2 pole, IP54| ||Flachdichtung, 2polig, IP54| Dimensions see page 65 / Massbilder siehe Seite 65 > _62_ ~~ee~~ _www.schurter.com_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Quick connect terminals / Flachsteckeranschlüsse** ## **Basic type / Grundtyp** **==> picture [379 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> 25<br>48 16<br>23.7<br>44.1<br>P1 a 3 5<br>5.3 26.7 8.4 10.8<br>21.5 Quick connect terminal / Flachstecker<br>IEC 61210 A6,3–0,8<br>3.5<br>12.5<br>34<br>10.6<br>**----- End of picture text -----**<br> ## **Undervoltage release, remote trip release / Unterspannungsauslösung, Fernauslösung** **==> picture [380 x 226] intentionally omitted <==** **----- Start of picture text -----**<br> 25<br>48 16<br>23.7<br>44.1<br>P1 a 3 5<br>1.5<br>Quick connect terminal / Flachstecker<br>IEC 61210 A6,3–0,8<br>7.2 22 6.3 15.5<br>5.3 26.7 8.4 21.5<br>Quick connect terminal / Flachstecker<br>IEC 61210 A2,8–0,8<br>3.5<br>12.5<br>34<br>69<br>10.6<br>6<br>**----- End of picture text -----**<br> ## **Mechanical lock-out latch / Mechanische Schaltsperre** **==> picture [515 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> 25<br>48 16<br>* max. Schalthub<br>44.1<br>23.7<br>P1 a 3 3 5<br>2<br>Quick connect terminal<br>22.8 10.8 Flachstecker<br>5.3 26.7 8.4 17.5 IEC 61210 A6,3–0,8<br>19.5 5.5<br>*<br>3.5<br>12.5<br>34<br>50.6 57<br>10.6<br>2.5<br>8 3.5 2 8 3.5 2.8 2 7<br>(4.5) (4.5)<br>**----- End of picture text -----**<br> _www.schurter.com_ _63_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Screw clamp terminal / Schraubanschluss** ## **Basic type / Grundtyp** **==> picture [199 x 155] intentionally omitted <==** **----- Start of picture text -----**<br> 10.8<br>P1 a 3 5<br>10.8<br>Screw type M3,5x6 (Philips Form H)<br>Maximum torque 1 Nm<br>Klemmschraube M3,5x6 (Philips Form H)<br>zulässiger Anzugsdrehmoment 1 Nm<br>26.7<br>**----- End of picture text -----**<br> ## **Cut-out and pin-out / Montageöffnung und Anschlussbelegung** ## **Cut-out / Montageöffnung** ## **Pin-out / Anschlussbelegung** **==> picture [216 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> a b<br>1.0 44,5...45,0<br>1.5 44,5…45,0<br>2.0 44,7...45,2<br>2.5 44,7…45,2<br>3.0 44,8...45,3<br>4.0 44,9...45,4<br>b 5.0 45,0...45,5<br>Assemble<br>Einbaurichtung<br>edge must be sharp<br>scharfkantig<br>+0.2 –0.0<br>21.7<br>a (1.0 – 5.0)<br>**----- End of picture text -----**<br> **==> picture [129 x 113] intentionally omitted <==** **----- Start of picture text -----**<br> P2 P1<br>U-Relais b a<br>c<br>4<br>3<br>6<br>5<br>**----- End of picture text -----**<br> _www.schurter.com_ _64_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Accessories / Zubehör** **==> picture [229 x 312] intentionally omitted <==** **----- Start of picture text -----**<br> AZM01<br>56.6 33.6<br>50.5 27.5<br>48 19.2<br>AZM10<br>50 27<br>37.2 19.2<br>17.6<br>8.1 12.5<br>43.7<br>17.3<br>8.8<br>43.8<br>**----- End of picture text -----**<br> **==> picture [206 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> AZM13<br>50<br>27<br>AZZ04<br>14<br>33.2<br>10.6<br>**----- End of picture text -----**<br> **==> picture [255 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> 73<br>62<br>51 34.8<br>Ø 8 27<br>Ø 4.5<br>17.3 14.1 12.6 9 7<br>**----- End of picture text -----**<br> **==> picture [212 x 312] intentionally omitted <==** **----- Start of picture text -----**<br> AZM02/AZM03<br>33.6<br>56.5 27.5<br>50.5 19.2<br>AZM11/AZM12<br>50<br>48<br>17.6 15.3<br>43.7<br>17.3 14<br>43.8<br>**----- End of picture text -----**<br> **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> AZM14<br>**----- End of picture text -----**<br> **==> picture [213 x 167] intentionally omitted <==** **----- Start of picture text -----**<br> 27<br>50 19.2<br>AZZ51<br>Snap-on fastener / Schnapphaken<br>17.3 14<br>33.2<br>10.6<br>**----- End of picture text -----**<br> **==> picture [115 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> 54.6 x 28.3<br>20.1<br>86<br>**----- End of picture text -----**<br> **==> picture [34 x 250] intentionally omitted <==** _www.schurter.com_ _65_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Quick connect terminals / Flachsteckeranschlüsse** ## **Basic type with auxiliary contact / Grundtyp mit Hilfskontakt** **==> picture [329 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> 48 36.5<br>16<br>23.7 9<br>43.6<br>7 10 11 12<br>5.3 11.6 7.6 7.5 8.4 10.8 11<br>33<br>Quick connect terminal / Flachstecker<br>IEC 61210 A6,3–0,8<br>3.5<br>12.5<br>34.7<br>34<br>9<br>10.6<br>**----- End of picture text -----**<br> ## **Undervoltage release, remote trip release / Unterspannungsauslösung, Fernauslösung** **==> picture [396 x 215] intentionally omitted <==** **----- Start of picture text -----**<br> 36.5<br>48 16<br>23.7 9<br>43.6 10.8 11<br>7 10 11 12<br>1.5 15.5<br>Quick connect terminal / Flachstecker<br>IEC 61210 A6,3–0,8<br>22 6.3<br>10.8<br>5.3 11.6 7.6 7.5 8.4 33<br>3.5<br>12.5<br>6<br>34 34.7<br>9<br>10.6<br>Quick connect terminal Flachstecker IEC 61210 A2,8–0,8<br>69<br>**----- End of picture text -----**<br> ## **Mechanical lock-out latch / Mechanische Schaltsperre** **==> picture [514 x 183] intentionally omitted <==** **----- Start of picture text -----**<br> 36.5<br>48 16<br>* max. Schalthub<br>23.7 9<br>43.6<br>3 10.8 11<br>7 10 11 12<br>2<br>Quick connect terminal<br>17.5<br>22.8 Flachstecker<br>19.5<br>IEC 61210 A6,3–0,8<br>5.3 11.6 7.6 7.5 8.4 33 5.5<br>*<br>2.5<br>8 3.5 2 8 3.5 2.8 2 7<br>(4.5) (4.5)<br>3.5<br>12.5<br>34 34.7<br>57<br>9<br>10.6<br>**----- End of picture text -----**<br> _66 www.schurter.com_ **CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, ROCKER GERÄTESCHUTZSCHALTER, 2POLIG, WIPPENBETÄTIGT** **TA45** ## **Screw clamp terminal / Schraubanschluss** ## **Basic type with auxiliary contact / Grundtyp mit Hilfskontakt** **==> picture [224 x 162] intentionally omitted <==** **----- Start of picture text -----**<br> 10.8 10<br>9<br>7 10 11 12<br>Screw type M3,5x6 (Philips Form H)<br>Maximum torque 1 Nm<br>Klemmschraube M3,5x6 (Philips Form H)<br>zulässiger Anzugsdrehmoment 1 Nm<br>26.7<br>**----- End of picture text -----**<br> ## **Cut-out and pin-out / Montageöffnung und Anschlussbelegung** ## **Cut-out / Montageöffnung** **==> picture [104 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> b<br>+0.2 –0.0<br>33.2<br>a (1.0 – 5.0)<br>**----- End of picture text -----**<br> Assemble Einbaurichtung edge must be sharp scharfkantig **==> picture [76 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> a b<br>1.0 44,5...45,0<br>1.5 44,5...45,0<br>2.0 44,7...45,2<br>2.5 44,7...45,2<br>3.0 44,8...45,3<br>4.0 44,9...45,4<br>5.0 45,0...45,5<br>**----- End of picture text -----**<br> ## **Pin-out / Anschlussbelegung** **==> picture [218 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> P2 P1<br>b a<br>U-Relais Auxiliary contact<br>Hilfskontakt<br>10<br>c 11<br>4 12<br>3<br>6<br>5<br>**----- End of picture text -----**<br> _www.schurter.com_ _67_ _68 www.schurter.com_
Updated at February 9, 2023
SCHURTER is a globally recognized innovator and manufacturer of high-quality electronic components, specializing in products that ensure a safe and clean supply of power. With a strong reputation in the electronics and PCB assembly industries, the company delivers reliable solutions engineered to protect critical circuits, streamline device operation, and optimize electrical performance across diverse applications. The core of our SCHURTER portfolio revolves around comprehensive circuit protection. We carry an extensive selection of standard and resettable fuses, accompanied by robust fuse holders, to safeguard sensitive electronics against overcurrent conditions. Furthermore, our offering features high-performance thermal circuit breakers and associated accessories, providing dependable protection and rapid reset capabilities for demanding industrial and commercial environments. Beyond fundamental circuit protection, SCHURTER excels in electromagnetic compatibility (EMC) and RFI suppression technologies. Our range includes precision-engineered power line filters and common mode chokes designed to mitigate electromagnetic interference and ensure signal integrity. Accompanied by specialized components such as AC/DC LED power supplies, SCHURTER provides the meticulous engineering and durability necessary for modern, high-reliability electronic design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →