ABLS1A24031
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 75 W, 24 VDC, 3.13 A
- Manufacturer: SCHNEIDER ELECTRIC
- Product type:
- SVHC: To Be Advised
- Product Range: Modicon ABLS Series
- No. of Outputs: 1 Output
- Output Power Max: 75W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3.13A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 111.15 € |
| Current stock | 10+ |
| Lead time | 28 days |
## **Product datasheet** Specifications ## Regulated Power Supply, 100-240V AC, 24V 3.1 A, single phase, Optimized ABLS1A24031 ## **EAN Code: 3606481500205** ## **Main** **==> picture [215 x 169] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Range of product|Modicon Power Supply| |Product or component type|Power supply| |Power supply type|Regulated switch mode| |Variant option|Optimized| |Enclosure material|Plastic| |Nominal input voltage|100...240 V AC single phase| |100...240 V AC phase to phase| |140...340 V DC| |Rated power in W|75 W| |Output voltage|24 V DC| |Power supply output current|3.13 A| **----- End of picture text -----**<br> ## **Complementary** **==> picture [269 x 340] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Input voltage limits|85...264 V AC without temperature derating| |120...375 V DC without temperature derating| |Nominal network frequency|50…60 Hz| |Network system compatibility|TN| |TT| |IT| |Maximum leakage current|1 mA 240 V AC| |Input protection type|Integrated fuse (not interchangeable) 5 A| |External protection (recommended) 20 A Curve C| |External protection (recommended) 13 A Curve B| |External protection (recommended) 10 A Curve C| |Inrush current|40.0 A at 115 V| |80.0 A at 230 V| |Power factor|0.55 at 115 V AC| |0.45 at 230 V AC| |Efficiency|88 % at 230 V AC| |Output voltage adjustment|21.6...26.4 V| |Power dissipation in W|15 W| |Current consumption|< 1.8 A 115 V AC| |< 1 A 230 V AC| |< 0.8 A 140 V DC| |Turn-on time|< 1.2 s| |Holding time|> 20 ms 115 V AC| |> 40 ms 230 V AC| |Startup with capacitive loads|5000 µF| **----- End of picture text -----**<br> **24 Oct 2024** **1** **==> picture [342 x 357] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Residual ripple|< 120 mV| |Meantime between failure [MTBF]|700000 h at 25 °C, full load conforming to SR 332| |Output protection type|Against overload and short-circuits, protection technology: automatic reset| |Against over temperature, protection technology: manual reset| |Against overvoltage, protection technology: manual reset| |Connections - terminals|Screw connection: 0.5...2.5 mm², (AWG 20...AWG 14) for output| |Screw connection: 0.75...2.5 mm², (AWG 18...AWG 14) for input| |Line and load regulation|< 0.5 % at 0 to 100 % load at 25 °C| |< 1 % at full voltage range in line at 25 °C| |Status LED|1 LED (green) output voltage| |Depth|102 mm| |Height|123.6 mm| |Width|27 mm| |Net weight|0.22 kg| |Output coupling|Parallel| |Serial| |Mounting support|Top hat type TH35-15 rail conforming to IEC 60715| |Top hat type TH35-7.5 rail conforming to IEC 60715| |Double-profile DIN rail| |Supply|SELV conforming to IEC 60950-1| |SELV conforming to IEC 60204-1| |SELV conforming to IEC 60364-4-41| |Dielectric strength|3000 V AC with input to output| |Service life|10 year(s)| |Overvoltage category|II| **----- End of picture text -----**<br> **==> picture [206 x 306] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Environment| |Standards|IEC 62368-1| |EN/IEC 61010-1| |EN 61010-2-201| |EN/IEC 61204-3| |IEC 61000-6-1| |IEC 61000-6-2| |IEC 61000-6-3| |IEC 61000-6-4| |IEC 61000-3-2| |EN 61000-3-3| |UL 62368-1| |UL 61010-1| |UL 61010-2-201| |CSA C22.2 No 62368-1| |CSA C22.2 No 61010-1| |CSA C22.2 No 61010-2-201| |EN/IEC 62368-1| |Product certifications|CE| |CUL listed| |CUL recognized| |RCM| |CB Scheme| |EAC| |KC| |NEC: class 2| |Operating altitude|< 5000 m| |Shock resistance|150 m/s² for 11 ms| |IP degree of protection|IP20| **----- End of picture text -----**<br> **24 Oct 2024** **2** |**Ambient air temperature for**|-20…-10 °C with current derating of 1 % per °C mounting position A < 2000 m| |---|---| |**operation**|-10…40 °C without derating mounting position A 115 V AC < 2000 m| ||-10…50 °C without derating mounting position A 230 V AC < 2000 m| ||40…70 °C with current derating of 1.67 % per °C mounting position A 115 V AC <| ||2000 m| ||50…70 °C with current derating of 2.5 % per °C mounting position A 230 V AC <| ||2000 m| |**Electrical shock protection class**|Class I| |**Pollution degree**|2| |**Vibration resistance**|3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6| ||10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6| |**Electromagnetic immunity**|Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming| ||to IEC 61000-4-2| ||Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to| ||IEC 61000-4-2| ||Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz)| ||conforming to IEC 61000-4-3| ||Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming| ||to IEC 61000-4-3| ||Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming| ||to IEC 61000-4-3| ||Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC| ||61000-4-4| ||Surge immunity test - test level: 4 kV (between power supply and earth) conforming| ||to IEC 61000-4-5| ||Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5| ||Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming| ||to IEC 61000-4-6| ||Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC| ||61000-4-8| ||Immunity to voltage dips conforming to IEC 61000-4-11| ||Disturbing field emission conforming to EN 55016-2-3| ||Limits for harmonic current emissions conforming to IEC 61000-3-2| ||conforming to EN 55016-1-2| ||conforming to EN 55016-2-1| |**Electromagnetic emission**|Conducted emissions conforming to IEC 61000-6-3| ||Radiated emissions conforming to IEC 61000-6-4| |**Packing Units**|| |**Unit Type of Package 1**|PCE| |**Number of Units in Package 1**|1| |**Package 1 Height**|3.700 cm| |**Package 1 Width**|14.000 cm| |**Package 1 Length**|16.000 cm| |**Package 1 Weight**|317.000 g| |**Unit Type of Package 2**|S03| |**Number of Units in Package 2**|22| |**Package 2 Height**|30.000 cm| |**Package 2 Width**|30.000 cm| |**Package 2 Length**|40.000 cm| |**Package 2 Weight**|7.634 kg| |**Unit Type of Package 3**|P06| |**Number of Units in Package 3**|176| |**Package 3 Height**|75.000 cm| |**Package 3 Width**|60.000 cm| |**Package 3 Length**|80.000 cm| **24 Oct 2024** **3** **Package 3 Weight** 67.000 kg **Contractual warranty** 18 months **Warranty** **24 Oct 2024** **4** ## **Sustainability** **Green Premium[TM] label** is Schneider Electric’s commitment to delivering products with best-inclass environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. **Guide to assessing product sustainability** is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. Learn more about Green Premium Guide to assess a product’s sustainability Transparency RoHS/REACh ## **Well-being performance** Mercury Free Rohs Exemption Information Yes ## **Certifications & Standards** **==> picture [397 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Reach Regulation|REACh Declaration| |Eu Rohs Directive|Pro-active compliance (Product out of EU RoHS legal scope)| |China Rohs Regulation|China RoHS declaration| |Environmental Disclosure|Product Environmental Profile| |Weee|The product must be disposed on European Union markets following specific waste| |collection and never end up in rubbish bins| |Circularity Profile|End of Life Information| **----- End of picture text -----**<br> **24 Oct 2024** **5** ## **Product datasheet** ## **ABLS1A24031** ## Dimensions Drawings ## **Electrical Safety** - If the unit is use in a manner not specified by the manufacturer, the protection provided by the equipment may - • be impaired. - For means of disconnection a switch or circuit breaker, located near the product, must be included in the - installation. A marking as disconnecting device for the product is required. - The device has an internal fuse. The unit is tested and approved with branch circuit protective device up to - - 20A. This circuit breaker can be used as disconnecting device. - The power supply is only suitable for audio, video, information, communication, industrial and control - • equipment. **24 Oct 2024** **6** **ABLS1A24031** **Product datasheet** ## **Dimensions** ## **Front and Side Views** **24 Oct 2024** **7** **ABLS1A24031** ## **Product datasheet** ## Connections and Schema ## **Connections and Schema** ## **Correct Parallel Connection** **(1) :** Load ## **Incorrect Parallel Connection** **(1) :** Load ABLx1Axxxxx-1 = ABLx1Axxxxx-2 max 2 x ABLx1Axxxxx L1 = L2 ∆V max 25 mV I < 90% 2 x I Load nom ## **Output Voltage Balancing** **24 Oct 2024** **8** **ABLS1A24031** ## **Product datasheet** **(1) :** RLoad1 **(2) :** RLoad2 R = R Load1 Load2 I = I = ~ I 1 2 nom ## **Series Connection** **(1) :** Vout1 **(2) :** Vout2 **(3) :** 2 x Diode, VRRM> 2 x Vout1/2, IF > 2 x Inom1/2 **(4) :** VLoad = 2 x Vout **(5) :** Load **24 Oct 2024** **9** **ABLS1A24031** **Product datasheet** ## **Connections and Schema** **(1) :** Ambient **24 Oct 2024** **10** **ABLS1A24031** ## **Product datasheet** ## Mounting and Clearance ## **Mounting** ## **Mounting Position A** ## **Mounting Position B** ## **Incorrect Mounting** **24 Oct 2024** **11** **ABLS1A24031** **Product datasheet** **24 Oct 2024** **12** ## **Product datasheet** ## **ABLS1A24031** ## Performance Curves ## **Performance Curve** ## **Mounting Position A** ## **Mounting Position B** **X :** Surrounding Air Temperature (°C) **Y :** Percentage of Maximum Load (%) > **1 :** Altitude ≤ 2000 m (6561 ft), Input voltage = 230 VAC / 325 VDC - **2 :** Altitude ≤ 2000 m (6561 ft), 115 VAC / 162 VDC - **3 :** Altitude ≤ 5000 m (16404 ft), Input voltage = 230 VAC / 325 VDC - **4 :** Altitude ≤ 5000 m (16404 ft), 115 VAC / 162 VDC **24 Oct 2024** **13** **ABLS1A24031** ## **Product datasheet** ## **DC input voltage** **X :** Surrounding Air Temperature (°C) **Y :** Percentage of Maximum Load (%) - **1 :** 110 VDC - **2 :** 90 VDC **3 :** 85 VDC **24 Oct 2024** **14** **ABLS1A24031** **Product datasheet** Image of product / Alternate images ## **Alternative** **24 Oct 2024** **15** **ABLS1A24031** **Product datasheet** **24 Oct 2024** **16** **Product datasheet ABLS1A24031** **24 Oct 2024** **17**
Updated at June 4, 2026
Schneider Electric is a recognized global leader in digital automation and energy management, dedicated to bridging progress and sustainability. By integrating world-leading process and energy technologies, they empower industries, infrastructure, and facilities to maximize efficiency and reliability. The company is renowned across the electronics and electrical sectors for manufacturing robust, innovative control and protection components that drive the digital transformation of industrial systems. Our comprehensive portfolio of Schneider Electric products strongly focuses on high-performance switching and automation control. We carry an extensive selection of relays, including hundreds of power relays, solid-state relays, contactors, and critical safety relays designed for demanding operational environments. For automation and process control applications, the range provides essential equipment such as motor starters, visual signal indicator units, process controllers, and versatile industrial switch accessories. To ensure the safety and integrity of electrical installations, we also supply a robust lineup of Schneider Electric circuit protection devices. This includes a wide array of thermal-magnetic circuit breakers, specialized fuse holders, and residual current devices. Supported by precision panel instrumentation, dependable AC/DC converters, and specialized DIN rail terminal blocks, our offering equips engineers with the critical components required for comprehensive industrial control and energy management solutions.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →