ABLP1A24045
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 100 W, 24 VDC, 4.5 A
- Manufacturer: SCHNEIDER ELECTRIC
- Product type: AC / DC Enclosed Power Supplies
- SVHC: To Be Advised
- Product Range: Modicon ABLP Series
- No. of Outputs: 1Outputs
- Output Power Max: 100W
- Current, Output 4: -
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 4.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 72.3 € |
| Current stock | 10+ |
| Lead time | 28 days |
## **Product data sheet** Specifications ## Regulated Power Supply, 100...240V AC, 24V 4.5A, single phase, Panel Mount ABLP1A24045 ## **Main** |**Main**|| |---|---| |**Range of product**|Modicon Power Supply| |**Product or component type**|Power supply| |**Power supply type**|Regulated switch mode| |**Variant option**|Panel mount| |**Enclosure material**|Aluminium| |**Nominal input voltage**|100...240 V AC single phase| |**Input voltage limits**|90...264 V AC| |**Rated power in W**|100 W| |**Output voltage**|24 V DC| |**Power supply output current**|4.5 A| ## **Complementary** |**Complementaryplementarylementaryy**|| |---|---| |**Nominal network frequency**|50…60 Hz| |**Network system compatibility**|TN| ||TT| ||IT| |**Maximum leakage current**|1 mA 240 V AC| |**Input protection type**|Integrated fuse (not interchangeable) 4 A| |**Inrush current**|45 A at 115 V| ||85 A at 230 V| |**Power factor**|0.55 at 115 V AC| ||0.45 at 230 V AC| |**Efficiency**|89 % at 230 V AC| |**Output voltage adjustment**|21.6...26.4 V| |**Power dissipation in W**|20 W| |**Current consumption**|< 2.3 A 115 V AC| ||< 1.5 A 230 V AC| |**Turn-on time**|< 500 ms| |**Holding time**|> 20 ms 115 V AC| ||> 40 ms 230 V AC| |**Startup with capacitive loads**|4000 µF| |**Residual ripple**|< 150 mV| **Dec 7, 2021** **1** |**Expected capacitor life time**|10 year(s)| |---|---| |**Meantime between failure**|700000 h at 25 °C, full load conforming to SR 332| |**[MTBF]**|| |**Output protection type**|Against overload and short-circuits, protection technology: automatic reset| ||Against over temperature, protection technology: manual reset| ||Against overvoltage, protection technology: manual reset| |**Connections - terminals**|Screw connection: 0.75...2.5 mm², (AWG 18...AWG 14) without wire end ferrule| ||Screw connection: 0.75...1.5 mm², (AWG 18...AWG 16) with wire end ferrule| |**Line and load regulation**|< 0.5 %line| ||< 1 %load| |**Status LED**|1 LED (green)output voltage| |**Depth**|129 mm| |**Height**|30 mm| |**Width**|97 mm| |**Net weight**|0.3 kg| |**Output coupling**|Parallel| ||Serial| |**Mounting support**|Top hat type TH35-15 rail conforming to IEC 60715| ||Top hat type TH35-7.5 rail conforming to IEC 60715| ||Double-profile DIN rail| ||panel mounting| |**Supply**|SELV conforming to EN/IEC 60950-1| ||SELV conforming to EN/IEC 60204-1| ||SELV conforming to IEC 60364-4-41| |**Environment**|| |**Standards**|EN 62368-1| ||EN 61010-1| ||EN 61010-2-201| ||EN 61204-3| ||EN 61000-6-1| ||EN 61000-6-2| ||EN 61000-6-3| ||EN 61000-6-4| ||EN 61000-3-2| ||EN 61000-3-3| ||UL 62368-1| ||UL 61010-1| ||UL 61010-2-201| ||CSA C22.2 No 62368-1| ||CSA C22.2 No 61010-1| ||CSA C22.2 No 61010-2-201| ||EN/IEC 62368-1| |**Product certifications**|CE| ||CULus| ||EAC| ||RCM| ||CB Scheme| ||KC| |**Environmental characteristic**|3M4 conforming to IEC 60721-3-3| |**Operating altitude**|5000 m| |**Shock resistance**|100 m/s² for 11 ms| |**IP degree of protection**|IP10| |**Ambient air temperature for**|-30…70 °C| |**operation**|| |**Ambient air temperature for**|-40…85 °C| |**storage**|| |**Relative humidity**|0…95 % without condensation| |**Overvoltage category**|II| |**Electrical energy source class**|ES1| |**conforming to IEC 62368-1**|| **2** **Dec 7, 2021** **Electrical shock protection** Class I **class** |**Pollution degree**|2| |---|---| |**Vibration resistance**|3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6| ||10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6| |**Electromagnetic immunity**|Immunity to electrostatic discharge - test level: 6 kV (contact discharge) conforming to EN/IEC| ||61000-4-2| ||Immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2| ||Immunity to conducted RF disturbances - test level: 10 V/m (80 MHz...2 GHz) conforming to EN/IEC| ||61000-4-3| ||Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC| ||61000-4-3| ||Immunity to conducted RF disturbances - test level: 3 V/m (2.7...6 GHz) conforming to EN/IEC| ||61000-4-3| ||Immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4| ||Surge immunity test - test level: 3 kV (between power supply and earth) conforming to EN/IEC| ||61000-4-5| ||Surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5| ||Immunity to conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC| ||61000-4-6| ||Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8| ||Immunity to voltage dips conforming to EN/IEC 61000-4-11| ||Disturbing field emission conforming to EN 55016-2-3| ||Limits for harmonic current emissions conforming to EN 61000-3-2| ||Conducted disturbance emission conforming to EN 55016-1-2| ||Conducted disturbance emission conforming to EN 55016-2-1| |**Electromagnetic emission**|Conducted emissions conforming to EN 61000-6-3| ||Radiated emissions conforming to EN 61000-6-4| |**Dielectric strength**|3750 V AC input to output| |**Packing Units**|| |**Unit Type of Package 1**|PCE| |**Number of Units in Package 1**|1| |**Package 1 Weight**|420 g| |**Package 1 Height**|4 cm| |**Package 1 width**|14.8 cm| |**Package 1 Length**|18.5 cm| |**Unit Type of Package 2**|S03| |**Number of Units in Package 2**|19| |**Package 2 Weight**|8.546 kg| |**Package 2 Height**|30 cm| |**Package 2 width**|30 cm| |**Package 2 Length**|40 cm| ## **y** |**Offer Sustainability**<br>**Sustainable offer status**|| |---|---| |**Sustainable offer status**|Green Premium product| |**REACh Regulation**|REACh Declaration| |**EU RoHS Directive**|Pro-active compliance (Product out of EU RoHS legal scope)| ||EU RoHS Declaration| |**Mercury free**|Yes| |**RoHS exemption information**|Yes| |**China RoHS Regulation**|China RoHS declaration| |**Environmental Disclosure**|Product Environmental Profile| |**Circularity Profile**|End of Life Information| |**WEEE**|The product must be disposed on European Union markets following specific waste collection and| ||never end up in rubbish bins| **Dec 7, 2021** **3** **California proposition 65** WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov **4** **Dec 7, 2021** **Product data sheet** Dimensions Drawings **ABLP1A24045** ## **Electrical Safety** - ●If the unit is use in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. - ●The power supply is only suitable for audio, video, information, communication, industrial and control equipment. **Dec 7, 2021** **5** **Product data sheet** Dimensions Drawings **ABLP1A24045** ## **Dimensions** ## **Front and Side Views** **6** **Dec 7, 2021** **Product data sheet** Connections and Schema **ABLP1A24045** ## **Connections and Schema** ## **Correct Parallel Connection** **(1) :** Load ## **Incorrect Parallel Connection** **(1) :** Load ABLx1Axxxxx-1 = ABLx1Axxxxx-2 max 2 x ABLx1Axxxxx L1 = L2 ∆V max 25 mV LLoad < 90% 2 x Lnom ## **Output Voltage Balancing** **(1) :** RLoad1 **(2) :** RLoad2 RLoad1= RLoad2 I1= I 2= ~ I nom **Dec 7, 2021** **7** ## **Series Connection** **==> picture [168 x 36] intentionally omitted <==** **----- Start of picture text -----**<br> (1) : Vout1<br>(2) : Vout2<br>(3) : 2 x Diode, VRRM> 2 x Vout1/2, IF > 2 x Inom1/2<br>**----- End of picture text -----**<br> **(4) :** VLoad = 2 x Vout **(5) :** Load **8** **Dec 7, 2021** **Product data sheet** Connections and Schema **ABLP1A24045** ## **Connections and Schema** **(1) :** Ambient **Dec 7, 2021** **9** **Product data sheet** Performance Curves **ABLP1A24045** ## **Performance Curves** ## **Mounting Position A, B, F and G** ## **Mounting Position C** ## **Mounting Position H** **X :** Surrounding Air Temperature **Y :** Percentage of Max Load (%) **1 :** Altitude 2000 m **2 :** Altitude 5000 m Note : < 115 VAC additional derating by 0.6% / V **10** **Dec 7, 2021** **Product data sheet** Mounting and Clearance **ABLP1A24045** ## **Mounting** ## **Mounting Position A** ## **Mounting Position B** ## **Mounting Position C** ## **Mounting Position F** **Dec 7, 2021** **11** ## **Mounting Position G** ## **Mounting Position H** **12** **Dec 7, 2021**
Updated at June 4, 2026
Schneider Electric is a recognized global leader in digital automation and energy management, dedicated to bridging progress and sustainability. By integrating world-leading process and energy technologies, they empower industries, infrastructure, and facilities to maximize efficiency and reliability. The company is renowned across the electronics and electrical sectors for manufacturing robust, innovative control and protection components that drive the digital transformation of industrial systems. Our comprehensive portfolio of Schneider Electric products strongly focuses on high-performance switching and automation control. We carry an extensive selection of relays, including hundreds of power relays, solid-state relays, contactors, and critical safety relays designed for demanding operational environments. For automation and process control applications, the range provides essential equipment such as motor starters, visual signal indicator units, process controllers, and versatile industrial switch accessories. To ensure the safety and integrity of electrical installations, we also supply a robust lineup of Schneider Electric circuit protection devices. This includes a wide array of thermal-magnetic circuit breakers, specialized fuse holders, and residual current devices. Supported by precision panel instrumentation, dependable AC/DC converters, and specialized DIN rail terminal blocks, our offering equips engineers with the critical components required for comprehensive industrial control and energy management solutions.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →