Image not available
Illustrative purposes only
ABC-1/4
CARTRIDGE FUSES
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON / PARTNER STOCK
- Product type: Cartridge Fuses
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 75 |
| Price | 4.32 € |
| Current stock | 1000+ |
| Lead time | 30 days |
**SMALL DIMENSION (ELECTRONIC) FUSES** ## **1/4” x 1-1/4” Fast-Acting Fuses** **AGC ABC GBB** [ Fast-Acting [ Fast-Acting Very Fast-Acting **Physical Size:** 1/4” x 1-1/4” **Physical Size:** 1/4” x 1-1/4” **Physical Size:** 1/4” x 1-1/4” (6.3mm x 32mm) (6.3mm x 32mm) (6.3mm x 32mm) **Construction:** Glass Tube, Nickel- **Construction:** Ceramic Tube **Construction:** Ceramic Tube plated brass endcaps. **Voltage Rating:** See Below **Voltage Rating:** See Below **Voltage Rating:** See Below **Interrupting Rating:** See Below **Agency Approvals: Interrupting Rating:** See Below **Agency Approvals:** UL recognized product meets standard 248- **Agency Approvals:** UL Listed product meets standard 248-14 14 UL Listed product meets standard 248-14 UL Listed Guide & File numbers (ABC UL Recognized Card: GBB 1-30A (JFHR2, UL Listed Card: AGC 1/500-10 1/4-15A): JDYX & E19180. E56412) UL Listed product meets standard 248-14 UL Listed Card: AGC 1/500-10 UL Recognition Card: AGC 11-30 CSA Component Acceptance Card (Class No. 1422 30) CSA Component Certified Card (Class 1422-01 File 53787) |**Agency Approvals:**<br>UL Listed product meets standard 248-14<br>UL Listed Guide & File numbers (ABC<br>1/4-15A): JDYX & E19180.|||UL recognized product meets standard 248-<br>14<br>UL Recognized Card: GBB 1-30A (JFHR2,<br>E56412)<br>CSA Component Certified Card (Class| |---|---|---|---| |UL Recognition Guide & File numbers|||CSA Component Certified Card (Class| |(ABC 20-30A): JDYX2 & E19180.|||1422-01 File 53787)| |CSA Certification Record No: 053787|||| |C 000 & Class No: 1422 01 & 1422|||**Product Code & Voltage Rating**| |30.<br>**Electrical Characteristics**<br>**Current**<br>**Rated**<br>**AC Interrupting**<br>**Rating**<br>**Voltage**<br>**Rating1**<br>AC(Max.)<br>DC(Max.)<br>250V<br>125V<br>1/4<br>250V<br>125V<br>35A 10000A<br>1/2<br>250V<br>125V<br>35A 10000A<br>3/4<br>250V<br>125V<br>35A 10000A<br>1<br>250V<br>125V<br>35A 10000A<br>1-1/2<br>250V<br>125V<br>100A 10000A<br>2<br>250V<br>125V<br>100A 10000A<br>2-1/2<br>250V<br>125V<br>100A 10000A<br>3<br>250V<br>125V<br>100A 10000A<br>4<br>250V<br>125V<br>200A 10000A<br>5<br>250V<br>125V<br>200A 10000A<br>6<br>250V<br>125V<br>200A 10000A<br>7<br>250V<br>125V<br>200A 10000A<br>8<br>250V<br>125V<br>200A 10000A<br>10<br>250V<br>125V<br>200A10000A|||**Product**<br>**Voltage**<br>**Code**<br>**Rating**<br>**AC**<br>**DC**<br>GBB-1<br>250V<br>125V<br>GBB-1-1/4<br>250V<br>125V<br>GBB-2<br>250V<br>125V<br>GBB-3<br>250V<br>125V<br>GBB-4<br>250V<br>125V<br>GBB-5<br>250V<br>125V<br>GBB-6<br>250V<br>125V<br>GBB-7<br>250V<br>125V<br>GBB-8<br>250V<br>125V<br>GBB-9<br>250V<br>125V<br>GBB-10<br>250V<br>125V<br>GBB-12<br>250V<br>125V<br>GBB-15<br>250V<br>125V<br>GBB-20<br>250V<br>125V<br>GBB-25<br>125V<br>125V<br>GBB-30<br>125V<br>125V<br>~~a~~<br>~~ee~~<br>~~ee~~<br>~~a~~<br>~~ee~~<br>~~ee~~<br>~~rs ee~~<br>~~ee~~<br>~~es~~<br>~~ee~~<br>~~re~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~re~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~re~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~es~~<br>~~ee~~<br>~~ee~~<br>~~a~~<br>~~eeeee~~<br>~~ee~~<br>~~es~~<br>~~ee~~<br>~~re~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~es~~<br>~~re~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~es~~| CSA Certification Card (Class No. 1422 01) ## **Electrical Characteristics** |**Current**|**Rated**|**AC Interrupting**|**AC Interrupting**|**AC Interrupting**||**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**|**Electrical Characteristics**||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**Rating**|**Voltage**||**Rating1**|||||**Current**<br>**Rated**|||||**AC Interrupting**|**AC Interrupting**| ||**AC(Max.)**|**250V**|**125V**|**32V**||||**Rating**<br>**Voltage**|||||**Rating1**|| |1/20|250V|35V|10000A|1000A||||AC(Max.)||DC(Max.)|||250V|125V| |1/16|250V|35V|10000A|1000A||||1/4<br>250V||125V|||35A|10000A| |1/10|250V|35V|10000A|1000A||||1/2<br>250V||125V|||35A|10000A| |1/8|250V|35V|10000A|1000A||||3/4<br>250V||125V|||35A|10000A| |3/16|250V|35V|10000A|1000A||||1<br>250V||125V|||35A|10000A| |2/10|250V|35V|10000A|1000A||||1-1/2<br>250V||125V|||100A|10000A| |1/4|250V|35V|10000A|1000A||||2<br>250V||125V|||100A|10000A| |3/10|250V|35V|10000A|1000A||||2-1/2<br>250V||125V|||100A|10000A| |3/8|250V|35V|10000A|1000A||||3<br>250V||125V|||100A|10000A| |45/100|250V|35V|10000A|1000A||||4<br>250V||125V|||200A|10000A| |1/2|250V|35V|10000A|1000A||||5<br>250V||125V|||200A|10000A| |3/4|250V|35V|10000A|1000A||||6<br>250V||125V|||200A|10000A| |1|250V|35V|10000A|1000A||||7<br>250V||125V|||200A|10000A| |1-1/4|250V|100A|10000A|1000A||||8<br>250V||125V|||200A|10000A| |1-1/2|250V|100A|10000A|1000A||||10<br>250V||125V|||200A|10000A| |2|250V|100A|10000A|1000A||||12<br>250V||125V|||200A|10000A| |2-1/4|125V|100A|10000A|1000A||||15<br>250V||125V|||750A|10000A| |2-1/2|125V|100A|10000A|1000A||||20<br>250V||125V|||400A|1000A| |3|125V|100A|10000A|1000A||||25<br>125V||125V|||–|1000A| |4|125V|200A|10000A|1000A||||30<br>125V||125V|||–|1000A| |5|125V|200A|10000A|1000A||1Interrupting ratings were measured at 70% - 80% power factor on|||||Interrupting ratings were measured at 70% - 80% power factor on|Interrupting ratings were measured at 70% - 80% power factor on||Interrupting ratings were measured at 70% - 80% power factor on| |6|125V|200A|10000A|1000A||AC, and at a time constant described in UL 198L.||||||||| |7|125V|200A|10000A|1000A||||||||||| |8|125V|200A|10000A|1000A||||**CROSS REFERENCE**||**CROSS REFERENCE**||||| |9|125V|200A|10000A|1000A||||**NEW**<br>**OLD**||||||| |10|125V|200A|10000A|1000A||||**EDISON**<br>**EDISON**||**BUSS**||**GOULD**||**LF**| |15|32V|–|–|1000A||||ABC<br>BBC||ABC||GAB||314| |20|32V|–|–|1000A||||||||||| |25|32V|–|–|1000A||||||||||| |30|32V|–|–|1000A||||||||||| |**Current**<br>**Rating**|**Rated**<br>**Voltage**|**Rated**<br>**Voltage**|**AC Interrupting**<br>**Rating1**|**AC Interrupting**<br>**Rating1**| |---|---|---|---|---| ||AC(Max.)|DC(Max.)|250V|125V| |1/4<br>1/2<br>3/4|250V<br>250V<br>250V|125V<br>125V<br>125V|35A <br>35A <br>35A|10000A<br> 10000A<br> 10000A| |1<br>1-1/2<br>2|250V<br>250V<br>250V|125V<br>125V<br>125V|35A <br>100A <br>100A|10000A<br> 10000A<br> 10000A| |2-1/2<br>3<br>4|250V<br>250V<br>250V|125V<br>125V<br>125V|100A <br>100A <br>200A|10000A<br> 10000A<br> 10000A| |5<br>6<br>7|250V<br>250V<br>250V|125V<br>125V<br>125V|200A <br>200A <br>200A|10000A<br> 10000A<br> 10000A| |8<br>10<br>12<br>15|250V<br>250V<br>250V<br>250V|125V<br>125V<br>125V<br>125V|200A <br>200A <br>200A <br>750A|10000A<br> 10000A<br> 10000A<br> 10000A| |20<br>25<br>30|250V<br>125V<br>125V|125V<br>125V<br>125V|400A <br>–<br>–|1000A<br>1000A<br>1000A| |**CROSS REFERENCE**|**CROSS REFERENCE**|**CROSS REFERENCE**|**CROSS REFERENCE**|**CROSS REFERENCE**| |---|---|---|---|---| |**NEW**<br>**EDISON**|**OLD**<br>**EDISON**|**BUSS**|**GOULD**|**LF**| |GBB|—|GBB|None|322| 1Interrupting ratings were measured at 70% - 80% power factor on AC, and at a time constant described in UL 198L. |1Interrupting ratings were measured at 70% - 80% power factor onInterrupting ratings were measured at 70% - 80% power factor on<br>AC, and at a time constant described in UL 198L.|1Interrupting ratings were measured at 70% - 80% power factor onInterrupting ratings were measured at 70% - 80% power factor on<br>AC, and at a time constant described in UL 198L.|1Interrupting ratings were measured at 70% - 80% power factor onInterrupting ratings were measured at 70% - 80% power factor on<br>AC, and at a time constant described in UL 198L.|1Interrupting ratings were measured at 70% - 80% power factor onInterrupting ratings were measured at 70% - 80% power factor on<br>AC, and at a time constant described in UL 198L.|1Interrupting ratings were measured at 70% - 80% power factor onInterrupting ratings were measured at 70% - 80% power factor on<br>AC, and at a time constant described in UL 198L.| |---|---|---|---|---| |**CROSS REFERENCE**||||| |**NEW**<br>**EDISON**|**OLD**<br>**EDISON**|**BUSS**|**GOULD**|**LF**| |AGC|BGC|AGC|GGC|312| **45**
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →