Image not available
Illustrative purposes only
A53TP50D-10
SOLID STATE RELAYS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA/CRYDOM
- Product type:
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 231.34 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **53TP SERIES | IP00** PANEL MOUNT ## Features - Three-phase solid-state relay; Ratings 25 A, 50 A per phase @ 48-530 VAC - 2 package styles IP00 or IP20 (See IP20 spec sheet for more information) - SCR output for heavy industrial loads - Transient protection built in - AC or DC control - Zero-crossing (resistive loads) or random-fire (inductive loads) output - LED input status indicator - UL Recognized, CE Compliant to EN60950-1 ## **PRODUCT SELECTION** |**Description**|**25 A**|**50 A**| |---|---|---| |**Operating Voltage (47-63Hz) [Vrms]**|48-530|48-530| |**Transient Overvoltage [Vpk]2**<br>~~ee~~|1200<br>~~ee~~|1200<br>~~ee~~| |**Maximum Off-State Leakage Current @ Rated**<br>**Voltage [mArms]**|10|10| |**Minimum Off-State dv/dt @ Maximum Rated**<br>**Voltage [V/sec]3**|500|500| |**Maximum Load Current [Arms]4**|25|50| |**Minimum Load Current [Arms]**|0.05<br>~~ee~~|0.05<br>~~ee~~| |**Maximum Surge Current 50-60 Hz (16.6ms)**<br>**[Apk]**|239/250<br>~~ee~~|597/625<br>~~ee~~| |**Maximum On-State Voltage Drop @ Rated**<br>**Current [Vpk]**|1.6|1.6| |**Thermal Resistance Junction to Case (Rjc)**<br>**[°C/W]**|1.02|0.63| |**Maximum I²t for Fusing 50-60 Hz (8.3 msec) [A²**<br>**sec]**<br>~~SS~~|285/260|1779/1620| |**Minimum Power Factor (with Maximum Load)**<br>~~SS~~|0.5|0.5| Page 1 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## Input[(1)] **==> picture [542 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> Description D53 A53<br>Control Voltage Range 4-32 VDC 90-280 Vrms<br>Minimum Turn-On Voltage 4.0 VDC 90 Vrms<br>Minimum Turn-Off Voltage 1.0 VDC 10 Vrms<br>Minimum Input Current (for on-state) 19 mA @ 4V 2.2 mA @ 120V<br>Maximum Input Current 25 mA @ 32V 10mA @ 240V<br>Nominal Input Impedance Current Limiter Current Limiter<br>Maximum Turn-On Time [msec] [5] 1/2 Cycle 50<br>Maximum Turn-Off Time [msec] 1/2 Cycle 50<br>**----- End of picture text -----**<br> ## General[(1)] **==> picture [542 x 192] intentionally omitted <==** **----- Start of picture text -----**<br> Description Parameters<br>Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms<br>Minimum Insulation Resistance (@ 500 V DC) 10 [9] Ohms<br>Maximum Capacitance, Input/Output 8 pF<br>Ambient Operating Temperature Range -40ºC to 80ºC<br>Ambient Storage Temperature Range -40ºC to 125ºC<br>Weight (typical) 10.3 oz (315g)<br>Encapsulation Thermally conductive Epoxy<br>Terminals Nickel plated Brass<br>Screws and Saddle clamps Zinc plated Steel<br>Input Terminal Screw Torque Range:[in lbs/Nm] 8-10 / 0.9-1.1<br>Output Terminal Screw Torque Range:[in lbs/Nm] 15-20 / 1.7-2.2<br>**----- End of picture text -----**<br> ## **THERMAL DERATE INFORMATION** **==> picture [166 x 154] intentionally omitted <==** **----- Start of picture text -----**<br> A53TP25D, D53TP25D<br>80 100<br>0.5°C/W<br>1°C/W 105<br>60<br>110<br>40<br>1.5°C/W<br>115<br>20<br>120<br>0<br>5 10 15 20 25 20 40 60 80<br>Load Currect [Arms] Max Ambient Temp. [ °C]<br>Power Dissipation °C]<br>Base Plate Temp [<br>**----- End of picture text -----**<br> **==> picture [233 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> D53TP50D, D53TP50D<br>180 90<br>.25°C/W<br>150 95<br>.5°C/W<br>120 100<br>105<br>90<br>1°C/W 110<br>60<br>1.5°C/W 115<br>30<br>120<br>0<br>10 20 30 40 50 20 40 60 80<br>Load Currect [Arms] Max Ambient Temp. [ °C]<br>Power Dissipation °C]<br>Base Plate Temp [<br>**----- End of picture text -----**<br> Page 2 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## **WIRING DIAGRAM** **==> picture [285 x 267] intentionally omitted <==** **----- Start of picture text -----**<br> A1 LOAD AC<br>O ++<br>LOAD CAN BE WIRED IN EITHER POSITION<br>© -- ><br>A2 LOAD AC<br>B1 LOAD AC<br>LOAD CAN BE WIRED IN EITHER POSITION<br>B2 LOAD AC<br>C1 LOAD AC<br>LOAD CAN BE WIRED IN EITHER POSITION<br>C2 LOAD AC<br>**----- End of picture text -----**<br> ## **MECHANICAL SPECIFICATIONS** Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Page 3 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. Example : A53TP25D-H-10 ## **ORDERING OPTIONS** **==> picture [546 x 215] intentionally omitted <==** **----- Start of picture text -----**<br> A 53TP 25 D - H -10<br>Control Voltage<br>D: DC (4-32V)<br>A: AC (90-280V)<br>Series<br>53TP<br>Load Current<br>25: 25 Amps<br>50: 50 Amps<br>Thermal Pad<br>Blank: Not Included<br>H: Included<br>Switching Mode<br>Required for valid part number<br>For options only and not required for valid part<br>**----- End of picture text -----**<br> ## **GENERAL NOTES** - (1) All parameters at 25°C unless otherwise specified. - (2) Relay will self trigger between 900-1200 Vpk. (3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (4) Heat sinking required, see page 4 for derating curves. > (5) Turn-on time for Random turn-on versions is 0.02 msec (DC Control Models) Page 4 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## **AGENCY APPROVALS & CERTIFICATIONS** Input: Output: EN61000-4-2, Level 3 ESD EN61000-4-2, Level 4 ESD EN61000-4-4, Level 3 Burst EN61000-4-4, Level 4 Burst EN61000-4-5, Level 4 Surge EN60950: Meets the requirements of sections 1.5: 1,7 : 2.9: 2.10.5.3: 4.2: 4.5: 4.7:: E116950 LR 81689 ## **WARNINGS** RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Page 5 Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (877) 502 5500 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev. 04/01/21 ECN 21039 FDE-07-01 Rev. B Copyright © 2020 Sensata Technologies, Inc. www.sensata.com
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.