Image not available
Illustrative purposes only
A1210
SSR, PANEL MOUNT, 240VAC, 280VAC, 10A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA/CRYDOM
- Product type:
- C; SSR, PANEL MOUNT, 240VAC, 280VAC, 10A; Contact Configuration:SPST-NO; Load Current:10A; Operating Voltage Max:140VAC; Relay Mounting:Panel; Relay Terminals:Screw; Switching Mode:
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 30.62 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Panel Mount** _DataSheet_ ## _**Series 1 240 VAC**_ - Ratings from 10A to 125A @ 24-280 VAC - SCR output for heavy industrial loads - Zero turn-on or instantaneous turn-on outputs - UL/CSA/VDE Approved, CE Compliant to EN60950-1 - Improved SEMS screw and washer - AC or DC control - Direct bond copper substrate - EMC compliant to Level 3 - Direct power lead frame - Epoxy free design - Redesigned housing with anti-rotation barriers ## For **Generation 3** datasheet click here ## **PRODUCT SELECTION** |**Control Voltage**|**10A**|**25A**|**50A**|**75A**|**90A**|**110A**|**125A**| |---|---|---|---|---|---|---|---| |3-32 VDC|D2410|D2425|D2450|D2475|D2490|D24110|D24125| |90-280 VAC|A2410|A2425|A2450|A2475|A2490|A24110|A24125| |18-36 VAC|A2410E|A2425E|A2450E|A2475E|A2490E|A24110E|A24125E| ## **AVAILABLE OPTIONS** **Control Voltage A:** 90-280 VAC **D:** 4-32 VDC **AxxxxE:** 18-36 VAC **Overvoltage Protection Snubber Switching Type Blank:** Not Included **Blank:** Not Included **Blank:** Zero Voltage Turn-On **P:** Included **(8) S:** Included **-10:** Instantaneous Turn-On **(9)** **Output Frecuency Operating Blank:** 47-63 Hz **Voltage** **4:** 400 Hz **24:** 24-280 VAC **Rated Load Current** **10:** 10 Amps **25:** 25 Amps **40:** 40 Amps **50:** 50 Amps **75:** 75 Amps **90:** 90 Amps **110:** 110 Amps **125:** 125 Amps **Termination Input Status LED Thermal Pad Blank:** Screw **Blank:** Not Included **Blank:** Not Included **F:** Quick Connect **(7) G:** Included **H:** Included (Up to 50 Amps only) **K:** Hex standoffs **(14)** Required for valid part number For options only and not required for valid part number ***** Not all part number combinations are available. Contact Crydom Technical support for information on the availability of a specific part number. ## **OUTPUT SPECIFICATIONS[(1)]** |**Description**|**10A**|**25A**|**50A**|**75A**|**90A**|**110A**|**125A**| |---|---|---|---|---|---|---|---| |Operating Voltage (47-440Hz) [Vrms]**(2)**|24-280|24-280|24-280|24-280|24-280|24-280|24-280| |Transient Overvoltage [Vpk]|600|600|600|600|600|600|600| |Maximum Off-State Leakage Current @ Rated Voltage [mArms]**(3)**|1|1|1|1|1|1|1| |Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]|500|500|500|500|500|500|500| |Maximum Load Current [Arms]**(4)**|10|25|50|75|90|110|125| |Minimum Load Current [mArms]|150|150|150|150|150|250|250| |Maximum 1 Cycle Surge Current (50/60Hz) [Apk]|115/120|239/250|597/625|954/1000|1145/1200|1432/1500|1670/1750| |Maximum On-State Voltage Drop @ Rated Current [Vrms]|1.15|1.15|1.15|1.15|1.15|1.15|1.15| |Thermal Resistance Junction to Case (Rjc) [°C/W]|1.03|0.8|0.45|0.3|0.27|0.25|0.22| |Maximum 1/2 Cycle I²t for Fusing (50/60Hz) [A²sec]|66/60|285/259|1770/1621|4555/4150|6560/5976|10249/9338|13950/12709| |Minimum Power Factor (at Maximum load)**(8)**|0.5|0.5|0.5|0.5|0.5|0.5|0.5| **Do not forget to visit us at:** _**www.crydom.com**_ Copyright © 2014 Crydom Inc. Specifications subject to change without notice. ## **Panel Mount** _DataSheet_ ## **INPUT SPECIFICATIONS[(1)]** |**Description**|**D24xx**|**A24xx**|**A24xxE**| |---|---|---|---| |Control Voltage Range|3-32 VDC|90-280 Vrms|18-36 Vrms| |Maximum Reverse Voltage|-32 VDC|-|-| |Minimum Turn-On Voltage|3.0 VDC **(5)**|90 Vrms|18 Vrms| |Minimum Turn-Off Voltage|1.0 VDC|10 Vrms|4 Vrms| |Minimum Input Current [mA]|7|5|16| |Maximum Input Current [mA]|12|10|20| |Nominal Input Impedance [Ohms]||Current Regulated|| |Maximum Turn-On Time [msec]|1/2 Cycle **(6)**|20|20| |Maximum Turn-Off Time [msec]|1/2 Cycle|30|30| ## **GENERAL SPECIFICATIONS[(1)]** |**Description**|**Parameters**| |---|---| |Dielectric Strength, Input/Output/Base (50/60Hz)|4000 Vrms| |Minimum Insulation Resistance (@ 500 VDC)|109Ohm| |Maximum Capacitance, Input/Output|8 pF| |Ambient Operating Temperature Range|-40 to 80°C| |Ambient Storage Temperature Range|-40 to 125°C| |Weight (typical)|2.6 oz (74.9g)| |Housing Material|94 V-0| |Baseplate Material|Aluminum| |Input Terminal Screw Torque Range (in-lbs/Nm)|13-15 /1.5-1.7| |Load Terminal Screw Torque Range (in-lbs/Nm)|18-20 / 2.0-2.2| |SSR Mounting Screw Torque Range (in-lbs/Nm)|18-20 / 2.0-2.2| |Input/Load Terminal Screw Torque Range (in-lbs/Nm)**(14)**|w/”K”option 8-10 / 0.9-1.13| |Humidity|85% non-condensing| |LED Input Status Indicator|w/”G”option (green)| |MTBF (Mean Time Between Failures) at 40°C ambient temperature**(15)**|11,641,553 hours(1,328years)| |MTBF (Mean Time Between Failures) at 60°C ambient temperature**(15)**|7,210,376 hours(823years)| ## **WIRING DIAGRAM** **==> picture [503 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> AC Recommended Wire Sizes Input Current vs Input Voltage<br>O V Standard Regulated “DC” Inputs<br>Terminals Wire Size Wire Pull-Out 25<br>Load (13) (Solid / Stranded) Strength (lbs)[N]<br>20<br>24 AWG (0.2 mm [2] ) / 0.2 [minimum] 10 [44.5]<br>1 ( ) 2 ( ) Input 2 x 12 AWG (3.3 mm [2] ) / 3.3 [maximum] 90 [400] 15<br>ft<br>20 AWG (0.5 mm [2] ) / 0.518 [minimum] 30 [133] 10<br>Oar eet<br>1 OUTPUT 2 Output 2 x 10 AWG (5.3 mm [2] ) / 5.3 110 [490] 5<br>S O L I D S T AT E R E L AY 2 x 8 AWG (8.4 mm [2] ) / 8.4 [maximum] 90 [400] 0<br>0 5 10 15 20 25 30<br>4 INPUT 3 DC Input Voltage<br>4 (– / ) 3 (+ / )<br>Input Current (mA)<br>**----- End of picture text -----**<br> ## **EQUIVALENT CIRCUIT BLOCK DIAGRAMS** **==> picture [467 x 74] intentionally omitted <==** **----- Start of picture text -----**<br> Diagram: Series 1 AC control Diagram: Series 1 DC control<br>AC 4 1 AC -DC 4 1 AC<br>Current<br>ConverterAC/DC Limiter TriggerCircuit (11) (10) TriggerCircuit (11)<br>( 10) (12) (12)<br>AC 3 2 AC +DC 3 2 AC<br>Current<br>Limiter<br>**----- End of picture text -----**<br> **Do not forget to visit us at:** _**www.crydom.com**_ Copyright © 2014 Crydom Inc. Specifications subject to change without notice. **Panel Mount** _DataSheet_ ## **MECHANICAL SPECIFICATIONS[(1)]** Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] **==> picture [534 x 421] intentionally omitted <==** **----- Start of picture text -----**<br> Screw Termination Hex Standoff Termination (“K” Option) (14)<br>1.1 1.1<br>[27.9] Mounting [22.6]0.89 [27.9]0.49 Mounting Hole/Slot [26.4]1.04<br>0.49 Hole/Slot 0.19 [4.9]<br>[12.4] 0.19 [4.9] [12.4] DIA.<br>DIA.<br>1 OUTPUT 2 1 OUTPUT 2<br>[47.6]1.88 S O L I D S T AT E R E L AY [43.2]1.7 [57.3]2.25 [47.6]1.88 S O L I D S T AT E R E L AY [43.2] 1.70 [57.3]2.25<br>4 INPUT 3 4 INPUT 3<br>1.0 0.93<br>1.0 [25.4] [23.6]<br>[25.4] (4 places)<br>1.75<br>1.75 [44.5] 1.0<br>[44.5] [25.4]<br>(2 places)<br>Quick Connect Termination (“F” Option) - Up to 25 Amp (7) Quick Connect Termination (“F” Option) - Up to 50 Amp (7)<br>1.58 1.1 Faston Terminal (16)<br>[40.2] Faston Terminal (16) 1.31 [27.9] 0.25 x 0.032 1.31<br>Mounting Hole/Slot 0.19 [4.9] [12.4]0.49 0.25 x 0.032 (2 places) [33.4] Mounting Hole/Slot 0.19 [4.9] [16.0]0.63 (4 places) 0.45 [33.4]<br>DIA. DIA. [11.4]<br>(2 places)<br>1 OUTPUT 2 1 OUTPUT 2<br>1.88 S O L I D S T AT E R E L AY 1.7 2.25 1.88 S O L I D S T AT E R E L AY 1.7 2.25<br>[47.6] [43.2] [57.3] [47.6] [43.2] [57.3]<br>4 INPUT 3 4 INPUT 3<br>inl | =) TS |<br>1.40 0.49<br>[35.6] Faston Terminal (16) [12.4] Faston Terminal (16)<br>FF [44.5]1.75 0.187 x 0.020 (2 places) [31.8]1.25 a [35.6]1.40 0.187 x 0.020 (2 places) [31.8]1.25<br>1.75<br>[44.5]<br>**----- End of picture text -----**<br> ## **GENERAL NOTES** - **(1)** - **(2)** For “S” option, operating voltage frequency is 47-63Hz. - **(3)** For parts with option “S” maximum leakage current is 10mA. - **(4)** Heat sinking required, see derating curves. For “K” option maximum current up to 50 Amp. - **(5)** Increase minimum voltage by 1V for operations from -20 to -40°C. - **(6)** Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models). - **(7)** Single pair (up to 25A) Double pair* (50A model only). ***Caution:** User must connect to both pairs. - **(8)** Output will self trigger between 450-600Vpk, Min. power factor 0.7 or higher, not suitable for capacitive loads. - **(9)** Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only. - **(10)** Elective Input Status LED, “G” option. - **(11)** Elective Overvoltage Protection, “P” option. - **(12)** Elective Internal Snubber, “S” option. - **(13)** Load can be wired to either SSR output terminal 1 or 2. - **(14)** Option “K” is intended only for use in attaching a printed circuit board to the SSR or mounting the SSR to a printed circuit board (PCB minimum thickness is 0.031 in) - **(15)** All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). - **(16)** Mechanical dimensions vary fro m G3 models. **Do not forget to visit us at:** _**www.crydom.com**_ Copyright © 2014 Crydom Inc. Specifications subject to change without notice. ## **Panel Mount** _DataSheet_ ## **SURGE CURRENT INFORMATION** **==> picture [510 x 514] intentionally omitted <==** **----- Start of picture text -----**<br> 10 A 25 A<br>120 250<br>. oa ..a<br>100 “sey 200 msn.<br>80 Ss,a ss brs ss,.<br>mae 150 Fotat<br>60<br>100<br>40<br>20 50<br>0 0<br>0.01 0.1 1 10 0.01 0.1 1 10<br>Surge Duration (Secs) Surge Duration (Secs)<br>50 A 75 A<br>600 Ss. 900 Se,ws<br>~~ 800 Ss,<br>500 se's,a 700 Ss. Ss. Ss.<br>Ss sy<br>400 — 600 Psy<br>Ss.se, 500 bra<br>300 Me: 400 te,<br>See Tse<br>200 See55 300 SheeL<br>Pewee. Moen.<br>200<br>100<br>100<br>0 0<br>0.01 0.1 1 10 0.01 0.1 1 10<br>Surge Duration (Secs) Surge Duration (Secs)<br>90 A 110 A<br>1200 1500<br>1050900 ..Sey 7g.,. 1200 ..SsSs. we,. .<br>ane Sey<br>750 ss,=, 900 Sa .s<br>Saal <.,<br>600450 ce. os Se. See, tee 600 .. 55 Se. See Se<br>300<br>300<br>150<br>0 0<br>0.01 0.1 1 10 0.01 0.1 1 10<br>Surge Duration (Secs) Surge Duration (Secs)<br>125 A<br>1800<br>1600<br>1400<br>1200<br>1000<br>Ssss.aloneSsos<4.csrai<br>800 a7<br>600<br>400<br>200<br>0<br>0.01 0.1 1 10<br>Surge Duration (Secs)<br>Surge Current (Amp) Surge Current (Amp)<br>Surge Current (Amp) Surge Current (Amp)<br>Surge Current (Amp) Surge Current (Amp)<br>Surge Current (Amp)<br>**----- End of picture text -----**<br> Non repetitive peak surge current at Tj initial 40ºC. **Do not forget to visit us at:** _**www.crydom.com**_ Copyright © 2014 Crydom Inc. Specifications subject to change without notice. ## **Panel Mount** _DataSheet_ ## **THERMAL DERATE INFORMATION** **==> picture [520 x 388] intentionally omitted <==** **----- Start of picture text -----**<br> 10 A 25 A 50 A<br>3ºC/W 5ºC/W No Heatsink 1.5ºC/W 2ºC/W 3ºC/W 0.7ºC/W 1ºC/W 1.5ºC/W 2ºC/W<br>10 eecwepocncncpoces, 25 eoweenpennnns 50 eneaeeic<br>8 oes, .'., ey <'. 20 oa-. .'. Se. Ssya 40 oe %. ..ce Ss se. ary<br>64 Sy ee ~~, ee a oe =e 1510 Pe * re ee me, ~. ~! a ' se 3020 ns a te— ~ —~ ™=, ~ ~~ ‘~_——,Oey lee— as, rs ‘= H<br>[=e oe | eo ~<br>2 5 10<br>0 0 0<br>20 30 40 50 60 70 80 20 30 40 50 60 70 80 20 30 40 50 60 70 80<br>Ambient Temperature (ºC) Ambient Temperature (ºC) Ambient Temperature (ºC)<br>75 A 90 A 110 A<br>0.5ºC/W 0.7ºC/W 1ºC/W 1.5ºC/W 0.5ºC/W 0.7ºC/W 1ºC/W 1.5ºC/W 0.5ºC/W 0.7ºC/W 1ºC/W 1.5ºC/W<br>756045 easesoeeeeen osnen ee— neeelnees . ee,=.. Ss Se. Ss. ss, . .Tes. =.*s, 4 9080706050 ceeceenece ee eet enon, eec. . aSee 8. ce.aa es. ee ee Bee 28.ry 12010080 ee Ses, me. 7s. -.. 7. ce. fey Sey een °s.,<br>3015 ——— a — — = —~- ' le— => a)—- 403020 — ae ae ae oe = _— = =, esees — —=) ——~e, ~ ba 604020 ——oe — —,—_ he — ~-———F = =| ~e, *s.—J“. 7<br>10<br>0 0 0<br>20 30 40 50 60 70 80 20 30 40 50 60 70 80 20 30 40 50 60 70 80<br>Ambient Temperature (ºC) Ambient Temperature (ºC) Ambient Temperature (ºC)<br>125 A<br>0.5ºC/W 0.7ºC/W 1ºC/W<br>120<br>100<br>80<br>—as8,sece zlen,ss,ss.<br>60 5,<br>40<br>aaa -. =. = ==ee —<br>20<br>0<br>20 30 40 50 60 70 80<br>Ambient Temperature (ºC)<br>Load Current (Amps) Load Current (Amps) Load Current (Amps)<br>Load Current (Amps) Load Current (Amps) Load Current (Amps)<br>Load Current (Amps)<br>**----- End of picture text -----**<br> **Do not forget to visit us at:** _**www.crydom.com**_ Copyright © 2014 Crydom Inc. Specifications subject to change without notice. **Panel Mount** _DataSheet_ ## **AGENCY APPROVALS** EN60950 : Meets the requirements of sections 1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 60068-2-6 : Vibration 0.33mm and 0.75 mm Amplitude over 10-55 Hz IEC 60068-2-27 : Shock Resistance 15g/11ms **==> picture [95 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> E116949 LR81689<br>**----- End of picture text -----**<br> 10143 UG (Not Applicable: -B and 4D) Series 1 has Environmental Product declarations type III conforming to ISO 14025. ## **ACCESORIES** ## _**New Accessories! Protective Cover & Hardware Kits**_ ## **Recommended Accessories** **==> picture [191 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> Protective Cover<br>Part number: KS101<br>Clear plastic cover compatible with all new<br>S1 designs. Safety covers provide added<br>protection from electric shock when<br>installing or checking equipment.<br>“hi t<br>Hardware Kit<br>Part number: HK4<br>Bag with 2 square brass accessories and 2<br>screw 8-32 x 5/8 for output. Used to mount<br>TMR1 lug terminals.<br>**----- End of picture text -----**<br> |||**Recommended Accessories**|**Recommended Accessories**||| |---|---|---|---|---|---| |**Cover**|**Hardware**<br>**Kit**<br>ro)|**Heat Sink**<br>**Part No.**<br>**Thermal Resistance**<br>**[ºC/W]**||**Lug Terminal**<br>**Thermal Pad**|**Thermal Pad**<br><>| |KS101|HK1<br>HK4|HS501DR<br>HS301 / HS301DR<br>HS251<br>HS202 / HS202DR<br>HS201 / HS201DR<br>HS172<br>HS151 / HS151DR<br>HS122 / HS122DR<br>HS103 / HS103DR<br>HS101<br>HS073<br>HS072<br>HS053<br>HS033<br>HS023|5.0<br>3.0<br>2.5<br>2.0<br>2.0<br>1.7<br>1.5<br>1.2<br>1.0<br>1.0<br>0.7<br>0.7<br>0.5<br>0.36<br>0.25|TRM1<br>TRM6|HSP-1<br>HSP-2| Rev. 103014 **Do not forget to visit us at:** _**www.crydom.com**_ Copyright © 2014 Crydom Inc. Specifications subject to change without notice. **Panel Mount** _DataSheet_ ## **DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO /** 危险 **HAZARD OF RIESGO DE RISQUE DE GEFAHR EINES RISCHIO DI** 存在电击、 **ELECTRIC DESCARGA DESCHARGE ELEKTRISCHE SCOSSA** 爆炸或电弧 **SHOCK, ELECTRICA O ELECTRIQUE N SCHLAGES ELETTRICA O** 闪烁危险 **EXPLOSION, EXPLOSION. OU EXPLOSION ODER EINER DELL’ESPLOSI OR ARC FLASH.** • Desconectar • Eteindre **EXPLOSION. ONE.** • 在操作此设 • Disconnect all todos los toutes les • Stellen Sie • Spenga tutta 备之前请先 power before suministros de sources jeglichen l'alimentazion 关闭电源。 installing or energia a este d'énergie de Strom ab, der e che fornisce working with equipo antes cet appareil dieses Gerät questa this equipment. de trabajar avant de versorgt, bevor apparecchiatu 若不遵守这些说明, con este equipo. travailler Sie an dem ra prima del 可能会导致严重的 • Verify all dessus de cet Gerät Arbeiten lavorare a questa 人身伤害甚至死亡。 connections • Verificar todas appareil durchführen apparecchiatu ra and replace all las conexiones • Vor dem covers before y colocar todas • Vérifier tous • Verificare tutti Drehen auf turning on las tapas antes connections, et i collegamenti Energie alle power. de energizer remettre tous Anschlüsse e sostituire el equipo. couverts en tutte le coperture **Failure to follow** olace avant de überprüfen prima della **these El** mettre sous und alle rotazione **instructions will incumplimiento** Abdeckungen sull'alimentazi one **result in death de estas De non-suivi de** ersetzen. **or serious injury. instrucciones ces instructions Unterlassung L'omissione di puede provocar provoquera la dieser seguire queste la muerte o mort ou des Anweisungen istruz ioni lesiones serias. lésions sérieuses können zum provocherà la sérieuses. Tode oder zu morte o di schweren lesioni serie Verletzungen führen. WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA /** 警告 **RISK OF MATERIAL DAMAGE AND HOT RISQUE DE DOMMAGE MATERIEL ET DE GEFAHR VON MATERIALSCHÄDEN UND ENCLOSURE SURCHAUFFE DU BOITIER GEHÄUSEERHITZUNG • •** Les panneaux latéraux du produit peuvent être **•** Die Seitenwände können heiß sein. Lassen Sie The product's side panels may be hot, allow the product to cool before touching. chauds. Laisser le produit refroidir avant de le das Produkt abkühlen, bevor Sie es berühren. **•** Follow proper mounting instructions including toucher. **•** Beachten Sie die Montageanweisungen, torque values. **•** Respecter les consignes de montage, et **•** Führen Sie keine Flüssigkeiten oder **•** Do not allow liquids or foreign objects to enter notamment les couples de serrage. Fremdkörper in das Produkt ein. **•** Ne pas laisser pénétrer de liquide ni de corps this product. étrangers à l'intérieur du produit. **Failure to follow these instructions can result in Le non-respect de cette directive peut entraîner,des lésions corporelles graves ou des Die Nichtbeachtung dieser Anweisung kannKörperverletzung oder Materialschäden serious injury, or equipment damage. dommages matériels. zur Folge haben. RIESGO DE DAÑOS MATERIALES Y DE RISCHIO DI DANNI MATERIALI E D'INVOLUCRO** 材料损坏和高温外壳的危险性 **SOBRECALENTAMIENTO DE LA UNIDAD CALDO** • **•** Los paneles laterales del producto pueden **•** I pannelli laterali dell'apparecchio possono 不要触碰。 产品的一侧面板可能很热,在其冷却前请 estar calientes. Esperar que el producto se enfríe antes de tocarlo. scottare; lasciar quindi raffreddare il prodotto • 遵照正确的安装说明,包括扭矩值。 **•** Respetar las instrucciones de montaje, y en prima di toccarlo. **•** Seguire le istruzioni di montaggio corrette. • 请勿让液体及其他异物进入本产品。 particular los pares de apretado. **•** No dejar que penetren líquidos o cuerpos **•** Non far entrare liquidi o oggetti estranei in questo apparecchio. extraños en el producto. **La mancata osservanza di questa precauzione può** 如不能正确执行这些操作说明, **Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. causare gravi rischi per l'incolumità personale o danni alle apparecchiature.** 极有可能造成严重人体伤害或者设备的损坏。 ~~a~~ **Do not forget to visit us at:** _**www.crydom.com**_ Copyright © 2014 Crydom Inc. Specifications subject to change without notice. **Panel Mount** _DataSheet_ ## **ANNEX - ENVIROMENTAL INFORMATION** The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. |Part<br>Name<br>~~_~~<br>~~Oe~~|Toxic or hazardous Substance and Elements<br>~~_~~|Toxic or hazardous Substance and Elements<br>~~_~~|Toxic or hazardous Substance and Elements<br>~~_~~|Toxic or hazardous Substance and Elements<br>~~_~~|Toxic or hazardous Substance and Elements<br>~~_~~|Toxic or hazardous Substance and Elements<br>~~_~~| |---|---|---|---|---|---|---| ||Lead<br>(Pb)<br>~~_~~<br>~~Oe~~|Mercury<br>(Hg)<br>~~_~~<br>~~on~~|Cadmium<br>(Cd)<br>~~_~~<br>~~©~~|Hexavalent<br>Chromium<br>(Cr (VI))<br>~~_~~<br>~~©~~|Polybrominated<br>biphenyls<br>(PBB)<br>~~_~~<br>~~©~~|Polybrominated<br>diphenyl ethers<br>(PBDE)<br>~~_~~| |Semiconductor die<br>~~Oe~~|~~Oe~~|~~on~~<br>~~oe~~|~~©~~<br>~~oe©~~|~~©~~<br>~~©~~|~~©~~<br>~~©~~<br>~~©~~|| |Solder<br>~~Oe~~<br>~~ee~~|~~Oe~~<br>~~ee~~|~~on ~~<br>~~ee~~<br>~~oe~~|~~© ~~<br>~~ee~~<br>~~oe©~~|~~©~~<br>~~ee~~<br>~~©~~|~~©~~<br>~~ee~~<br>~~©~~<br>~~©~~|~~ee~~| ## 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 |有毒有害物质或元素<br>件<br>部<br>名称<br>铅<br>汞<br>镉<br>六价铬<br>多溴联苯<br>(Pb)<br>(Hg)<br>(Cd)<br>(Cr (VI))<br>(PBB)<br>半导体芯片<br>焊接点<br>~~oe~~<br>~~ee ee~~<br>~~—~~<br>~~Ex | of co} lo~~|多溴二苯醚<br>(PBDE)| |---|---| |50|| **Do not forget to visit us at:** _**www.crydom.com**_ Copyright © 2014 Crydom Inc. Specifications subject to change without notice.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →